Loading...
HomeMy WebLinkAboutA500.1AX X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X FLEXIBLE FLASHING CONTINUOUS W/ FACE OF WEATHER BARRIER BEHIND STONE VENEER (BEYOND) WEATHERED STEEL PANEL FLASHING GYPSUM BOARD FIELD DRILLED WEEP @ 16" O.C. FLEXIBLE FLASHING G1 MTL STUD EXT 5/8" GYPSUM SHEATHING RIGID INSULATION W/ WEATHER BARRIER Z-GIRT 1'-1 7/8" (+) 23 8" 2" 1 1/2" ADHERED NATURAL STONE VENEER (COLORADO BUFF) ADHERED NATURAL STONE VENEER (SAN MIGUEL) 1" PROVIDE ANCHOR IN HEAD JOINTS AT PROJECTING STONE LAP SELF-ADHERED FLASHING OVER FELT METAL LATH 2 LAYERS #15 FELT MORTAR SETTING BED MORTAR SCRATCH COAT 37 6" R23 BLOWN IN FIBERGLASS INSULATION BLOWN IN INSULATION NETTING VAPOR RETARDER/AIR BARRIER FILM 2" RIGID INSULATION BOARD 37 CONT. GRAVEL STOP FRT CONTINUOUS WOOD BLOCKING CONTINUOUS CLEAT RIGID INSULATION W/ WEATHER BARRIER WEATHERED STEEL PANEL MTL STUD EXT. 5/8" GYPSUM SHEATHING ROOF MEMBRANE FLASHING 6" R25 ROCK WOOL INSULATION G1 AIR BARRIER RUN ROOF MEMBRANE COMPLETELY OVER BLOCKING AND LAP OVER THERMAX T.O.S. 163' - 5 1/2" SPRAY APPLIED SEALANT 37 CONT. GRAVEL STOP RUN ROOF MEMBRANE COMPLETELY OVER BLOCKING & LAP OVER THERMAX CONTINUOUS FRT WOOD BLOCKING CONCRETE DECK CONTINUOUS CLEAT WEATHERED STEEL PANEL 6" R25 ROCK WOOL INSULATION EXT. 5/8" GYPSUM SHEATHING MTL STUD RIGID INSULATION W/ WEATHER BARRIER ROCK BALLAST ROOF MEMBRANE FLASHING AIR BARRIER SPRAY APPLIED SEALANT 37 MTL STUD GYPSUM BOARD EXTERIOR 5/8" GYPSUM SHEATHING RIGID INSULATION W/ WEATHER BARRIER WEATHERED STEEL PANEL FLEXIBLE FLASHING OVER BLOCKING 6" R23 BLOWN IN FIBERGLASS INSULATION FIELD DRILLED WEEP @ 16" O.C. TAPE SEAL OVER FASTENER STOREFRONT ALIGN SEALANT CLG. RE: FINISH SCHED. CONTINUOUS WOOD BLOCKING 18 GA METAL FLASHING W/ DRIP EDGE. COLOR TO MATCH STOREFRONT. 2" RIGID INSULATION BOARD BLOWN IN INSULATION NETTING VAPOR RETARDER/AIR BARRIER FILM 37 EXTERIOR 5/8" GYPSUM SHEATHING RIGID INSUL W/ WEATHER BARRIER PAINTED 5/8" GYP. BOARD. SUSPENDED ON 3/4" HAT CHANNELS ON 1 1/2" CROSS FURRING COLD ROLLED CHANNELS WEATHERED STEEL PANEL FLEXIBLE FLASHING OVER BLOCKING FIELD DRILLED WEEP @ 16" O.C. CONTINUOUS FRT WOOD BLOCKING VARIES, RE: SECTION R30 FOIL FACED BATT INSULATION. FULLY TAPE SEAMS AND PERIMITER. 20 20 37 WEATHERED STEEL PANEL ON 2" Z- GIRTS FLEXIBLE FLASHING, LAP OVER TOP OF WEATHER BARRIER RIGID INSULATION W/ WEATHER BARRIER EXT 5/8" GYPSUM SHEATHING MTL STUD 6" R23" BLOWN IN INSULATION DRIP EDGE CONTINUOUS FRT WOOD BLOCKING STOREFRONT SYSTEM BACKER ROD & SEALANT WEATHERED STEEL PANEL AND FLEXIBLE FLASHING BEYOND SLOPED 18 GA METAL SILL MATCH COLOR OF WEATHERED METAL PANEL TURN UP METAL FLASHING ON FRONT EDGE OF SHIMS (1/2" MIN. BACK FROM FRONT FACE OF STOREFRONT). SLOPE 3/4" EXTERIOR PLYWOOD VAPOR RETARDER/AIR BARRIER FILM BLOWN IN INSULATION NETTING 2" RIGID INSULATION BOARD 37 WEATHERED STEEL PANEL FLEXIBLE FLASHING, EXTEND FROM WEATHER BARRIER OVER MTL. FLASHING W/ DRIP EDGE RIGID INSULATION W/ WEATHER BARRIER EXT 5/8" GYPSUM SHEATHING MTL STUD AIR SPACE 6" R23 BLOWN IN FIBERGLASS INSULATION STOREFRONT SYSTEM BACKER ROD & SEALANT WEATHERED STEEL PANEL BEYOND FIELD DRILLED WEEP @ 16" O.C. DRIP EDGE 18 GA METAL FLASHING W/ COLOR TO MATCH WEATHERED METAL CONTINUOUS FRT WOOD BLOCKING FLEXIBLE FLASHING BLOWN IN INSULATION NETTING VAPOR RETARDER/AIR BARRIER FILM 2" RIGID INSULATION BOARD 37 EXISTING STOREFRONT SEALANT WEATHERED STEEL PANEL RIGID INSULATION W/ WEATHER BARRIER EXTERIOR 5/8" GYPSUM SHEATHING DIAGONAL BRACING BLOWN IN INSULATION NETTING 6" R23 BLOWN IN FIBERGLASS INSULATION FIELD DRILLED WEEP @ 16" O.C. DRIP EDGE EXIST CONC BEAM EXIST BLOCKING EXIST GYP. ENCLOSURE CONTINUOUS FRT WOOD BLOCKING FLEXIBLE FLASHING, EXTEND FROM WEATHER BARRIER OVER MTL. FLASHING W/ DRIP EDGE 18 GA METAL FLASHING W/ COLOR TO MATCH WEATHERED METAL FLEXIBLE FLASHING 23 VAPOR RETARDER/ AIR BARRIER FILM MTL STUD 2" RIGID INSULATION BOARD 37 CAP ALL STL TUBES TO PREVENT WATER INFILTRATION MTL COPING CONTINUOUS WOOD BLOCKING VENT STRIP MTL DECK, RE: STRUCT MTL Z- GIRT FASTENED TO MTL DECK WEATHERED STEEL PANEL STL TUBE FRAME, RE: STRUCT. DRIP CAP TRIM, EXTEND ATTACHMENT FLANGE AS REQUIRED 157' - 8 1/2" B.O TUBE ALIGN W/ METAL ROOF EDGE @ SHAFT 3' - 5" TO ROOF SLOPE WEATHERED STEEL PANEL 2" RIGID INSULATION W/ WEATHER BARRIER 6" MTL. STUD @ 16" O.C. 5/8" EXTERIOR GYP. BOARD SHEATHING ADHERED NATURAL STONE VENEER (COLORADO BUFF) PROVIDE ANCHOR IN HEAD JOINTS OF PROJECTING STONE ADHERED NATURAL STONE VENEER (SAN MIGUEL) WEATHERED STL. SOFFIT BACKER ROD & SEALANT EXIST CONC COLUMN 9 5/8" 6" MTL. STUD FLEXIBLE FLASHING 23 23 2" 1" 8" METAL LATH 2 LAYERS # 15 FELT MORTAR SETTING BED LAP SELF-ADHERED FLASHING OVER FELT MORTAR SCRATCH COAT 37 9 3/4" LEVEL 2 114' - 0" F MEMBRANE, SECURED TO WALL WITH COUNTER-FLASHING REGLET SEALANT CANT STRIP 1'-0" EXIST. WALL W/ EXIST. MTL. PANEL SURFACE MTD. REGLET W/ SNAP IN COUNTER FLASHING EDGE SEALANT ROOF ASSEMBLY EXIST. FLOOR STRUCTURE 1.5 3 COAT STUCCO BUILDING PAPER LATH J-CLOSURE BACKER ROD AND SEALANT 2 HR RATED SHAFT WALL WEATHERED METAL PANEL RIGID INSULATION WITH WEATHER BARRIER 5/8" EXT. GYP. BOARD SHEATHING 6" MTL. STUDS AT 16" O.C. FLEXIBLE FLASHING LEVEL 2 114' - 0" 1/2" WEATHERED METAL PANEL 3" RIGID INSULATION WITH WEATHER BARRIER 5/8" EXT. GYP. BOARD SHEATHING 6" MTL. STUDS AT 16" O.C. SLOPED MTL. SILL FLASHING CONT. WEATHERMATE FLASHING, WRAPPED THROUGH OPENING CONTINUOUS FRT WD. BLOCKING SNAP TRIM BACKER ROD AND SEALANT STOREFRONT SYSTEM CONC. FLOOR SLAB RE: STRUCT. SLOPE 6" R25 ROCK WOOL INSULATION SPRAY ADHERED SEALANT WEATHERED METAL PANEL ASSEMBLY CANT STRIP CONT. ROOF MEMBRANE, TO PARAPET TAPERED ROOF INSUL. DENSDECK ROOF DECKING MTL. DECKING FIELD DRILLED WEEP AT 16" O.C. DRIP EDGE FLEXIBLE FLASHING HSS 4X4. RE: STRUCT WEATHERED METAL PANEL BACKER ROD AND SEALANT 1'-9 1/4" EXTERIOR GYP. BD. MTL. STUD FRAMING AS REQUIRED SPRAY FIRE PROTECTION AUTOMATIC ENTRANCE STORE FRONT WINDOW EDGE OF METAL PANEL ABOVE. EDGE OF METAL PANEL ABOVE. KNOX BOX G.5 2.3 1'-2" 8" 6" 7 1/2" 1'-1 3/4" RIGID INSULATION WITH WEATHER BARRIER 4" 1 1/2" 9 7/8" 26 A250.1A G.5 1'-1 3/4" EDGE OF METAL PANEL ABOVE WEATHERED METAL PANEL SYSTEM EXTERIOR GYP. BD. METAL STUD FRAMING AS REQUIRED BACKER ROD AND SEALANT AUTOMATIC ENTERANCE PAINTED GYP. BD. 33 RIGID INSULATION WITH WEATHER BARRIER 36 000 3" 6" 9" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 3" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 6/15/2016 2:45:19 PM A500.1A Checker Author EXTERIOR ENVELOPE DETAILS - METAL PANEL 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 3" = 1'-0" 2 WEATHERED STEEL ON STUD @ STONE 3" = 1'-0" 1 WEATHERED STEEL ON STUD @ ROOF EDGE 3" = 1'-0" 3 WEATHERED STEEL @ GRAVEL STOP & RIVER ROCK 3" = 1'-0" 4 WEATHERED STEEL @ STOREFRONT HEAD 3" = 1'-0" 6 WEATHERED STEEL @ SOFFIT 3" = 1'-0" 9 WEATHERED STL @ SILL 3" = 1'-0" 10 WEATHERED STL @ HEAD 3" = 1'-0" 11 WEATHERED STEEL @ EX STOREFRONT 3" = 1'-0" 7 WEATHERED STEEL @ SCREEN WALL 1 1/2" = 1'-0" 12 WEATHERED STEEL TRANSITION TO STONE 1 1/2" = 1'-0" 8 FLASHING ON EXISTING METAL PANEL 3" = 1'-0" 13 WEATHERED STEEL @ ELEVATOR SHAFT 3" = 1'-0" 14 WEATHERED STEEL ON STUD @ STOREFRONT SILL 3" = 1'-0" 15 WEATHERING STEEL @ VESTIBULE ROOF 3" = 1'-0" 5 ENLARGED PLAN @ VESTIBULE COLUMN 3" = 1'-0" 16 ENLARGED PLAN @ VESTIBULE 2 ADD #2 07.16.2015 4 ADD #4 09.21.2015 5 ADD #5 TOV, DFPC 10.20.2015 15 ASI #7 12.04.2015 20 ASI #12 02.03.2016 23 ASI #15 TBD 33 ASI #24 05.20.2016 36 ASI #27 Date 30 37 ASI #28 06.15.2016 **Issued as a sketch in original ASI ** 01/04/17