GENERAL DEMOLITION NOTES:
LEGEND:
WALLS/ITEMS TO BE REMOVED
ROOF DRAINS TO BE REMOVED, COORDINATE
EXTENT OF REMOVAL AND REUSE W/
MECHANICAL DRAWINGS
EQUIPMENT AND DUCTWORK TO BE REMOVED/RELOCATED
COORDINATE WITH MECHANICAL DRAWINGS
ROOF STEP STONES
1. DASHED LINES INDICATE ITEMS TO BE REMOVED. DEMOLITION OF WALLS INCLUDES ALL DOORS,
WINDOWS AND OTHER ITEMS LOCATED WITHIN THE WALL TO BE REMOVED UNLESS NOTED
OTHERWISE. RE: STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL FOR EXISTING
UTILITIES
2. FADED LINES INDICATE ITEMS TO REMAIN.
3. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONSTRUCTION RELATED CONDITIONS PRIOR
TO COMMENCEMENT OF DEMOLITION.
4. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO DEPARTMENTS OR AREAS THAT
ARE IN OPERATION AND SERVED BY SUCH SERVICES. COORDINATE ALL DISRUPTIONS OR
DISCONTINUATIONS OF UTILITIES AND SERVICES WITH OWNER.
5. ALL FURNISHINGS AND MOVABLE EQUIPMENT IN DEMOLITION/CONSTRUCTION AREA SHALL BE
REMOVED/RELOCATED BY OWNER PRIOR TO START OF DEMOLITION.
6. PATCH CORRIDOR WALLS AND RAILINGS TO MATCH EXISTING ADJACENT CONSTRUCTION,
PATCH ALL EXISTING WALLS, CEILINGS AND FLOOR TO REMAIN AFTER DEMOLITION IS
COMPLETE. COORDINATE EXTENT OF SELECTIVE DEMOLITION WITH PROJECT SEQUENCING
PLANS AND WITH OTHER TRADES. PATCH WALL BOXES AND OTHER WALL/CEILING OPENINGS
WHEREVER FIXTURES/OUTLETS ARE BEING REMOVED AND WALLS ARE TO REMAIN.
7. PROVIDE METAL STUD AND GYPSUM BOARD DUST/PRIVACY ENCLOSURES FOR DEMOLITION
WORK TO MAINTAIN SEPARATION OF CONSTRUCTION AND IN-USE SPACES. REFER TO SHEET
G002 FOR ADDITIONAL INFORMATION.
8. REVIEW DEMOLITION AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH AS-BUILT
STRUCTURAL DRAWINGS WHERE POTENTIAL OF ENCOUNTERING LOADED/STRUCTURAL
BEAMS/JOISTS/COLUMNS EXIST.
9. CORE-DRILL EXISTING FLOOR AND/OR ROOF AS REQUIRED FOR NEW PLUMBING OR ELECTRICAL
SYSTEMS. SAWCUT FLOOR SLABS TO SLAB DEPTH ONLY, TO PREVENT DAMAGE TO UNDER SLAB
UTILITIES.
10. CONTRACTOR TO COORDINATE I.C.R.A. (INFECTION CONTROL RISK ASSESSMENT) PLAN WITH
OWNER PRIOR TO COMMENCEMENT OF EACH PHASE/SUB-PHASE.
11. DEMOLITION WORK SHALL NOT REDUCE INTEGRITY OF STRUCTURE TO REMAIN NOR OF FIRE-
PROOFING/SEPARATION. MAINTAIN STRUCTURAL AND LIFE SAFETY INTEGRITY IN AREAS OF WORK
AT ALL TIMES.
12. VERIFY ALL ELECTRICAL AND PLUMBING REQUIREMENTS PRIOR TO REMOVING ANY EQUIPMENT.
13. PROVIDE SIGNAGE FOR TEMPORARY CIRCULATION AND EGRESS PATHS DURING DEMOLITION.
14. REFER TO MECHANICAL, PLUMBING & ELECTRICAL DRAWINGS FOR OTHER DEMOLITION
WORK AND WORK TO REMAIN IN PLACE, REQUIRED FOR EACH CONSTRUCTION
SEQUENCE.
15. NOTIFY OWNER AND ARCHITECT IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED.
ASBESTOS ABATEMENT (OR REMOVAL) TO BE PROVIDED BY OWNER UNDER SEPARATE
CONTRACT. COORDINATE WITH GENERAL CONTRACTOR FOR TIMING OF DEMOLITION IN RELATION
TO ABATEMENT TO WORK AT EACH CONSTRUCTION SEQUENCE AREA.
16. PATCH UNDER SLAB SYSTEMS AND FLOOR SLABS TO MATCH ADJACENT CONSTRUCTION AFTER
THE UNDER FLOOR PLUMBING WORK IS COMPLETED AND INSPECTED. REFER TO PLUMBING
DOCUMENTS.
17. NOTE THAT SOME SYSTEMS WILL REQUIRE WORK BEYOND CONSTRUCTION SEQUENCE ZONES IN
ORDER TO SUPPORT SPACES WITHIN EACH CONSTRUCTION SEQUENCE. COORDINATE THIS WORK
WITH GENERAL CONTRACTOR AND OWNER PRIOR TO STARTING WORK OUTSIDE OF
CONSTRUCTION SEQUENCE AREA. COORDINATE DEMOLITION/ CONSTRUCTION WORK HOURS,
CONSTRUCTION SEQUENCE AND CONSTRUCTION ACCESS WITH OWNER TO MINIMIZE DISRUPTION
OF NORMAL DAILY FUNCTION OF OWNER OCCUPIED AREAS.
18. NOTIFY OWNER AND ARCHITECT IF UNDER SLAB TEMPORARY DEWATERING IS REQUIRED.
19. REVIEW DEMOLITION DOCUMENTS WITH OWNER TO VERIFY ANY ITEMS TO BE SALVAGED AND
TURNED OVER TO THE OWNER.
20. NOISE DURING DEMOLITION TO BE KEPT TO A MINIMUM. COORDINATE WITH OWNER 72 HOURS
PRIOR TO COMMENCEMENT OF PARTICULARLY NOISY WORK SUCH AS CORE-DRILLING.
21. CONTRACTOR TO PROVIDE M.O.P. (METHOD OF PROCEDURE) PRIOR TO COMMENCEMENT OF
WORK IN ANY PHASE/SUB-PHASE WHICH AFFECTS HOSPITAL OPERATION. M.O.P.'S TO BE
APPROVED BY OWNER AT LEAST 72 HOURS PRIOR TO START OF WORK.
WALLS /ITEMS TO REMAIN
22. REFER TO SHEET G107.1A - G110.1A FOR SEQUENCING OF WORK, INCLUDING DEMOLITION.
MECH
ROOF ACCESS HATCH
FLUES AND VENTS TO BE REMOVED
23. SALVAGE BRICK FOR REUSE AT NEW AREAS OF BRICK AS REQUIRED BY ELEVATIONS.
A B C
D
E
000 4' 8' 16'
SCALE:
N
This document is the property of Heery International, Inc. and Heery International Inc. retains all
rights therein, including copyrights. It may only be used in a manner consistent with Heery
International Inc.'s rights while Heery International, Inc. is providing services for the specific project
identified or referred to herein or extensions thereto. It may not be used for any other purpose
except with the express written agreement of, and compensation to, Heery International Inc.
Copyright © 2013 by Heery International, Inc. all rights reserved.
WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42"
drawn by checked by
sheet number
sheet title
item date
date
issued for
seal/signature
consultants/construction managers
owner's project number
project number
1/8" = 1'-0"
Heery International
555 17th Street, Suite 500
Denver, CO 80202
720.946.0276
OWNER'S PROJECT NUMBER
5/28/2015 11:40:39 AM
AD104B.1A
Checker
Author
DEMOLITION ROOF
PLAN - LEVEL FOUR
- ZONE B
MAY 28,
2015
CONSTRUCTION
DOCUMENTS
VAIL VALLEY
MEDICAL CENTER
PHASE 1 - WEST WING
181 WEST MEADOW DRIVE
VAIL, CO
HII-1302604
INTERIOR DESIGN:
Gallun Snow
1920 Market Street,
Suite 240,
Denver, CO 80202 720.407.6002
MECHANICAL, ELECTRICAL,PLUMBING, LOW
VOLTAGE:
Cator Ruma & Associates,Co.
896 Tabor Street,
Lakewood, CO 80401-4700 303.232.6200
CIVIL:
Martin/Martin
225 Main Street,
Unit C101,
Edwards, CO 81632 970.926.6007
LANDSCAPE:
Lime Green Design, Inc.
900 East Louisiana Avenue,
Suite 209,
Denver, CO 80210 303.733.7558
STRUCTURAL:
Structural Consultants Inc.
3400 East Bayaud Avenue,
Suite 300,
Denver, CO 80209 303.399.5154
1/8" = 1'-0"
1
DEMOLITION PLAN - ROOF
DEMOLITION NOTES
1 REMOVE AND SALVAGE BRICK VENEER. REMOVE BALANCE OF
ASSEMBLY, INCLUDING ANCHORS, TO CONCRETE STRUCTURE
OR METAL STUDS. AT METAL STUDS. REMOVE ANY BATT OR
OTHER INSULATION BETWEEN STUDS.
2 REMOVE CURTAIN WALL ASSEMBLY INCLUDING ANCHORS.
3 EXISTING BRICK TO REMAIN
4 REMOVE DOOR, FRAME, AND ANCHORS
5 REMOVE BRICK AND CONCRETE BLOCK PARAPET ASSEMBLY IN
ITS ENTIRETY TO THE ROOF DECK CONCRETE ON METAL
6 REMOVE ROOF ASSEMBLY IN ITS ENTIRETY TO ROOF DECK,
CONCRETE ON METAL
7 REMOVE WALLS, CURB AND GATE
8 SALVAGE SIGNAGE (LETTERS) AND HAND OVER TO OWNER
9 REMOVE ALL OVER ENVELOPE CONSTRUCTION, INCLUDING BUT
NOT LIMITED TO, BRICK VENEER, SOFFITS, STOREFRONT, METAL
PANELS, METAL STUDS, ANCHORS, FURRING, AND INTERIOR
FINISHES TO CONCRETE COLUMNS AND CONCRETE BEAMS
10 REMOVE HANDRAIL/GUARDRAIL
11 REMOVE ALL EQUIPMENT PADS
12 REMOVE STOREFRONT AND METAL PANEL ASSEMBLY
INCLUDING ANCHORS, SHEATHING, METAL STUDS, BATT
INSULATION, AND INTERIOR FINISHES
13 REMOVE ALL FURRING AND FINISHES AT COLUMNS AND WALLS
TO REMAIN
14 DEMOLITION OF FOUNDATIONS THIS AREA; RE: STRUCT.
15 DEMOLITION OF LOUVERS AND STRUCTURES THIS AREA; RE:
MECH.
16 REMOVE METAL STAIRS
17 DEMOLISH SLAB AND WALL AS REQUIRED FOR EXISTING SEWER
REPAIR AND NEW WATER ENTRY; RE: PLUMB.
18 REMOVE WALL ASSEMBLY IN ITS ENTIRETY FOR NEW
STOREFRONT OPENING
19 REMOVE WALL IN ITS ENTIRETY; RE: STRUCT.
20 REMOVE PORTION OF CONCRETE BEAM BELOW; RE: STRUCT.
21 REMOVE CANOPY IN ITS ENTIRETY, EXCEPT COLUMN G4; RE:
STRUCT. AND MEP
22 EXISTING TO REMAIN
23 REMOVE ALL PARTITIONS AND INTERIOR FINISHES
24 REMOVE WALL, ROOF ASSEMBLY, AND STRUCTURE
25 REMOVE BRICK AND STOREFRONT ASSEMBLIES, INCLUDING
ANCHORS. EXISTING SHEATHING AND METAL STUDS TO REMAIN.
26 REMOVE PRECAST CONCRETE PLANKS OVER STAIRWELLS
KEY PLAN