E001
POWER LEGEND (Not all symbols listed below are used on these drawings) SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, HALF SWITCHED DUPLEX RECEPTACLE, CEILING MOUNTED DUPLEX RECEPTACLE, FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE, FLOOR MOUNTED SPECIAL RECEPTACLE SPECIAL RECEPTACLE, FLOOR MOUNTED JUNCTION BOX, WALL OR CEILING MOUNTED JUNCTION BOX, FLOOR MOUNTED DISCONNECT SWITCH (NON-FUSED) DISCONNECT SWITCH (FUSED) VARIABLE SPEED DRIVE WITH DISCONNECT UTILITY METER ELECTRICAL PANELBOARD, CONTROL PANEL, OR OTHER CABINET AS NOTED PLUG MOLD (MULTI-OUTLET ASSEMBLY) CONDUIT EXPOSED CONDUIT TURNING DOWN CONDUIT TURNING UP CONDUIT CAPPED MAIN SWITCHBOARD/DISTRIBUTION CENTER CURRENT TRANSFORMER GENERATOR ANNUNCIATOR PANEL CONDUIT, UNDERGROUND OR CONCEALED IN FLOOR AS ALLOWED PER SPECIFICATIONS BRANCH CIRCUIT HOME RUN, NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS, SUBSCRIPTS INDICATE PANEL & CIRCUITS DESCRIPTION SYMBOL DESCRIPTION SYMBOL CLG J J M WM A-1,3,5 T CT GANN MOTOR CONDUIT CONCEALED GROUND BAR TRANSFORMER THERMOSTAT ABBREVIATIONS LEGEND AMPERES ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ANNUNCIATOR ABOVE RAISED FLOOR AIR SAMPLING SMOKE DETECTION AUTOMATIC TRANSFER SWITCH BELOW FINISHED GRADE MOTOR CIRCUIT PROTECTOR SEE MECHANICAL EQUIPMENT SCHEDULE MINIMUM MAIN LUGS ONLY MANUAL TRANSFER SWITCH NORMALLY CLOSED NIGHT LIGHT NORMALLY OPEN NOT TO SCALE CONDUIT CABLE TELEVISION CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION EXISTING EMERGENCY EMERGENCY MAIN DISTRIBUTION CENTER EXPLOSION PROOF EMERGENCY POWER OFF EMERGENCY VENTILATION ON/OFF ELECTRIC WATER COOLER FIRE ALARM GROUND GENERATOR CONTROL PANEL GROUND FAULT INTERRUPTING HAND OFF AUTOMATIC ISOLATED GROUND MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MAIN DISTRIBUTION CENTER TRANSFORMER WEATHER PROOF WITHOUT WITH VARIABLE FREQUENCY DRIVE VOLTS UNINTERRUPTIBLE POWER SUPPLY UNLESS OTHERWISE NOTED UNDER GROUND UNDER FLOOR TYPICAL TRANSIENT VOLTAGE SURGE SUPPRESSER TAMPER PROOF SUB-DISTRIBUTION CENTER STAND-BY PULL BOX ON SITE WORK FORCE OWNER FURNISHED, OWNER INSTALLED OWNER FURNISHED, CONTRACTOR INSTALLED ON CENTER ABOVE COUNTER, MOUNT HORIZONTALLY TO CENTERLINE OF DEVICE, +6" ABOVE COUNTER OR BACK SPLASH NOT IN CONTRACT DESCRIPTION SYMBOL DESCRIPTION SYMBOL REFERENCE SYMBOLS LEGEND (Not all symbols listed below are used on these drawings) KITCHEN/OWNER/MEDICAL EQUIPMENT REFERENCE MECHANICAL EQUIPMENT REFERENCE EXISTING TO REMAIN EXISTING TO BE REMOVED EXISTING TO BE RELOCATED EXISTING TO REMAIN - REPLACE DEVICE DESCRIPTION DESCRIPTION SYMBOL A-1 1 LC1 UH E R RL ER SYMBOL (Not all symbols listed below are used on these drawings) T PM MDC MCC MCB MAX IG HOA GFI GCP G FA EWC EVO EPO EP EMDC EM (E) CCTV CB CATV C BFG ATS ASSD ARF ANN AFG AFF AC A XFMR WP W/O W/ VFD V UPS UON UG UF TYP TVSS TP SDC SB PB OSWF OFOI OFCI OC NTS NO NL NIC NC MTS MLO MIN MEC MCP WIREMOLD (SURFACE RACEWAY) SHADING INDICATES EMERGENCY SYSTEM TEXT INDICATES PANEL AND CIRCUIT DESIGNATION KEY NOTE REFERENCE PC K DIRECT DISTRIBUTION, WALL MOUNT LINEAR DECORATIVE LINEAR WALLMOUNT INDIRECT DISTRIBUTION, WALL MOUNT LINEAR LENSED TROFFER PATIENT OVERBED LIGHT SURFACE OR PENDANT MOUNTED LUMINAIRE DIRECT/INDIRECT TROFFER DIRECT/INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT INDIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT DIRECT DISTRIBUTION, SUSPENDED LINEAR PENDANT DIRECT/INDIRECT DISTRIBUTION, WALL MOUNT LINEAR STRIP LINEAR WALLMOUNT ADJUSTABLE ACCENT DOWNLIGHT WALL WASH DOWNLIGHT DOWNLIGHT SURFACE OR PENDANT MOUNTED STRIP OR INDUSTRIAL LUMINAIRE SURFACE DOWNLIGHT DARKROOM SAFE LIGHT (TWO COMPARTMENT SHOWN) EXIT LIGHT, ARROWS AS INDICATED, FACES INDICATED BY SHADING PORCELAIN KEYLESS LAMPHOLDER, BRYANT #5228 W/ 100W A19 UNDERCABINET LIGHT EMERGENCY LIGHTING UNIT EXTERIOR STAKE MOUNTED RECESS MOUNTED WALL LUMINAIRE I.F. LAMP. 'PC' INDICATES PULLCHAIN SQUARE ADJUSTABLE ACCENT DOWNLIGHT DECORATIVE PENDANT PENDANT DECORATIVE POLE POLE SQUARE DOWNLIGHT DECORATIVE ADJUSTABLE ACCENT DOWNLIGHT DECORATIVE WALL WASH DOWNLIGHT DECORATIVE DOWNLIGHT SQUARE WALL WASH DOWNLIGHT A a SWITCHING, UPPER CASE SUBSCRIPT INDICATES LUMINAIRE TYPE (TYP) SHADING INDICATES EM SYSTEM, LOWER CASE SUBSCRIPT INDICATES LIGHTING LEGEND DESCRIPTION SYMBOL DESCRIPTION SYMBOL (Not all symbols listed below are used on these drawings) BOLLARD DECORATIVE SCONCE WALL PACK OR EXTERIOR NON-DECORATIVE WALL SIGNAGE DOCK LIGHT TRACK HEAD THEATRICAL PIPE OR TRACK LIGHTING SQUARE ADJUSTABLE ACCENT DOWNLIGHT SQUARE DOWNLIGHT SQUARE WALL WASH DOWNLIGHT M LPA-# TYPICAL CIRCUIT NUMBER TYPICAL LUMINAIRE TYPE 1 TG# LIGHTING CONTROL / EQUIPMENT REFERENCE TYPICAL ROOM REFERENCE (TOP = RM #, BOTTOM = FLR) X X BRANCH WIRING GRADE BOLLARD; REFER TO PLAN AND LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION ANCHOR BOLTS INSTALLED PER MANUFACTURERS BOLT TEMPLATE 3#4 FULL HEIGHT WITH #3 TIES AT 24O.C. TYPE II, 3000 PSI CONCRETE X" Y" NO SCALE 16512.1 POLE BASE/BOLLARD DETAIL NO SCALE 16512.2 POLE BASE DETAIL - RAISED FINISH GRADE ANCHOR BOLTS INSTALLED PER MANUFACTURERS BOLT TEMPLATE X" Y2" 36" HAND HOLE WITH FLUSH COVER BOND TO GROUND WITHIN POLE #4 BARE COPPER GROUND BASE COVER SITE LIGHTING POLE; REFER TO PLAN AND LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION BRANCH CONDUIT 24" MIN. #4 TIE WIRES @ 12"O.C. #4 BARE COPPER GROUND WIRE WITH 4' COIL AT BOTTOM OF FOUNDATION 4#4 REBAR WELDED TO ANCHOR BOLTS ROUND CONCRETE BASE CON. MIN. STRENGTH 3000LBS @28 DAYS. 120V RECEPTACLE WITH SEPARATE CONDUIT SYSTEM IF SPECIFIED This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 5/28/2015 11:04:42 AM E001 Checker Author ELECTRICAL LEGENDS, NOTES AND DETAILS MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER Phase 1 West Wing 181 WEST MEADOW DRIVE VAIL, CO 13026.01 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE: Cator Ruma & Associates, Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 DEMOLITION NOTES: 1. 2. 3. 4. 5. 6. 7. UNLESS NOTED OTHERWISE, BOLD ITEMS INDICATE EQUIPMENT, DEVICES, ETC. TO BE REMOVED. DEMOLITION DRAWINGS MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. CONTRACTOR SHALL VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACILITATE ALL WORK INDICATED BY THE CONTRACT DOCUMENTS PRIOR TO QUOTATION. NO EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONTRACT DOCUMENTS. REWORK EXISTING TERMINATIONS, CONNECTIONS, CONDUIT, WIRING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT CONTINUITY TO EXISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR TO COMMENCEMENT OF ANY DEMO WORK, CONFIRM EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY INCLUDING ALL WIRING AND EXPOSED CONDUIT AND CONDUIT SUPPORTS BACK TO POINT OF ORIGIN OR NEXT DEVICE TO REMAIN. REMOVED ITEMS SHALL BE TURNED OVER TO THE OWNER, UNLESS NOTED OTHERWISE, AND STORED IN THE AREA DESIGNATED BY THE OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES NOT TO ACCEPT. WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUTED IN CONCRETE FLOOR SLABS, CONCRETE WALLS OR CONCRETE CEILINGS, THEY SHALL BE CUT BACK FLUSH WITH CONCRETE. FILL WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH FLUSH WITH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. REUSE EXISTING CONDUIT WHERE CURRENT NEC AND LOCAL CODE REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW INSTALLATIONS AND EXTENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN PLACE, DO NOT REINSTALL EXISTING CONDUIT. PROVIDE LABELING PER SPECIFICATIONS FOR REUSED CONDUIT. RELOCATED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MATERIAL. REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECTIVE OR DAMAGED DURING RELOCATION. WHERE EXISTING DEVICES, SWITCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL FINISH. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS NOTED OTHERWISE. GENERAL NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. WORK INCLUDED IN THE CONTRACT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. INSTALL CONDUIT CONCEALED IN FINISHED AREAS UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUIT TO MATCH EXISTING FINISHES WITHIN THE SURROUNDING AREA. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND ORDERING MATERIALS OR EQUIPMENT. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION ACTIVITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE/DATA/FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. EXISTING INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER FURNISHED DRAWINGS AND/OR LIMITED FIELD OBSERVATIONS. CATOR, RUMA & ASSOCIATES IS NOT RESPONSIBLE FOR THE ACCURACY OF ANY INFORMATION OR THE ADEQUACY, SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN AS EXISTING ON THESE DRAWINGS. FIELD LOCATE EXISTING UNDERGROUND PUBLIC AND OWNER UTILITIES OF ALL TRADES AND BUILDING GROUNDING/LIGHTNING PROTECTION SYSTEMS PRIOR TO ANY EXCAVATION. REPLACE OR REPAIR DAMAGED UTILITIES AND GROUNDING/LIGHTNING PROTECTION SYSTEMS TO ORIGINAL CONDITION. PROVIDE SEPARATE INSULATED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN AND BRANCH CIRCUITS. LIGHTING PLAN NOTES: 1. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH 120V AND 277V SINGLE PHASE CIRCUIT. PROVIDE STRIPING FOR FULL LENGTH OF NEUTRAL CONDUCTOR INSULATION TO MATCH THE COLOR CODE OF THE ASSOCIATED PHASE CONDUCTOR. SEE SPECIFICATION FOR COLOR CODES. POWER PLAN NOTES: 1. 2. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN. 08/11/15