HomeMy WebLinkAboutED100A-1AELBUPS ELB1S2 ELB1S1 UPS LBA1-1 LBK CDLBA EDLBA ELBA EHBA LBA HBA ELBA1 EHBC LBB ATS-6-EQ 600KW EMERGENCY GENERATOR T300 T75 PULL MAINS 'MDC' MDC EDPA EDPB ATS-4CR EHBC ATS #10-CR (CRITICAL BRANCH) ATS #11-EQ (EQUIPMENT BRANCH) ATS-5LS EH1L/EH2E ATS#12-CR CDHBB 'T1A' CDHBA CDHBB EXISTING MEDICAL AIR COMPRESSOR (MAC-1) E16 E18 SERVICE TRANSFORMER TO BE RELOCATED GDHBA 300KW GENERATOR (254 KW DERATED) HBA1 DPA T T ELDP EHDP EHBB LBA1 EDHBA E38 1 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ASI#20) DFPC: C&S 9667 (ADD#5) TI TBD 9/19/2016 11:44:51 AM ED100A.1A NCW CLP LOWER LEVEL POWER DEMO PLAN - ZONE A 11/16/2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE: Cator Ruma & Associates, Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 SCALE: 1/8" = 1'-0" LOWER LEVEL POWER DEMO PLAN - ZONE A KEYNOTES E16 RELOCATE AND EXTEND CONDUIT AND ASSOCIATED ELECTRICAL CONNECTIONS TO ALLOW TEMPORARY RELOCATION OF MAC-1 TO CHILLER ROOM AS INDICATED ON PD300A.1A. E18 REMOVE ALARM LIGHTING ASSOCIATED WITH CHILLER DURING CHILLER REMOVAL. E38 RELOCATED EXHAUST FAN (EF-15). RELOCATE AND EXTEND CONDUIT AND ASSOCIATED ELECTRICAL CONNECTIONS TO NEW LOCATION. REFER TO HVAC PLANS FOR NEW LOCATION. ADDENDUM #6 11.16.2015 1 ASI #23 04.08.2016 2 ASI #40 07.14.2016 1 2 01/04/17