Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
G102.1A
ACOUS ADD'L ADO ALT AB & ALUM. A.F.F ARCH @ BLKG BM BRG BOT B.O. BLDG CLG COL CONC CMU CFMF CFMS CFCI CONN CONST CJ CONT CONTR CSMU CW DET DEG DF DIAG DIA DIM DN DWGS EA EF EW EL ELEV EQ EQUIP EWC EXIST EFHC EJ EOS E.O.S. E.O.D. EXT FIN FE FEC FHC FH/EC FL FTG FD FDN F.O.S. F.O.M. GALV GA GB GYP. BD GIR GRD BM GWB HC HM HP HT H.TP H.O. HORIZ IF INSUL INT JT LT WT LLH LLV LP MCMWP MFR MO MAT'L MAX MECH MIN MISC NOM NIC NTS O.C. OFCI OFOI OPNG OPP OF PH PL PLBG PT P.T. PVC RAD RD REF RE: REINF REQ'D REV R.O. SCHED SECT SF SF SIM SOG SPECS SQ S.S. STN STL STD STL STRUC SYM THK'NS T.O. TV-A TV-C TV-CS TV-S TV-W TYP UNO VERT VIF VTR WWF W/ W/O WP WS WT ACOUSTICAL ADDITIONAL AUTOMATIC DOOR OPENER ALTERNATE ANCHOR BOLT AND ALUMINUM ABOVE FINISHED FLOOR ANGLE ARCHITECTURAL AT BLOCKING BEAM BEARING BOTTOM BOTTOM OF BUILDING CENTER LINE CEILING COLUMN CONCRETE CONCRETE MASONRY UNIT COLD FORM METAL FRAMING COLD FORM METAL STUD CONTRACTOR FURNISHED CONTRACTOR INSTALLED CONNECTION CONSTRUCTION CONTROL JOINT CONTINUOUS CONTRACTOR CALCIUM SILICATE MASONRY UNIT CURTAIN WALL DETAIL DEGREE DRINKING FOUNTAIN DIAGONAL DIAMETER DIMENSION DOWN DRAWINGS EACH EACH FACE EACH WAY ELEVATION ELEVATOR EQUAL EQUIPMENT ELECTRIC WATER COOLER EXISTING EXISTING FIRE HOSE CABINET EXPANSION JOINT EMERGENCY OVERFLOW SCUPPER EDGE OF SLAB EDGE OF DECK EXTERIOR FINISH FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FIRE HOSE/EXTINGUISHER CABINET FLOOR FOOTING FLOOR DRAIN FOUNDATION FACE OF STUD FACE OF MASONRY GALVANIZED GAUGE OR GAGE GYPSUM BOARD GYPSUM BOARD GIRDER GRADE BEAM GYPSUM WALL BOARD HANDICAPPED HOLLOW METAL HIGH POINT HEIGHT HIGH TEMP. HOLD OPEN HORIZONTAL INSIDE FACE INSULATION INTERIOR JOINT LIGHT WEIGHT LONG LEG HORIZONTAL LONG LEG VERTICAL LOW POINT METAL COMPOSITE MATERIAL WALL PANELS MANUFACTURER MASONRY OPENING MATERIAL MAXIMUM MECHANICAL MINIMUM MISCELLANEOUS NOMINAL NOT IN CONTRACT NOT TO SCALE ON CENTER OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OPENING OPPOSITE OUTSIDE FACE PENTHOUSE PLATE PLUMBING PAINT PRESSURE TREATED POLYVINYL CHLORIDE RADIUS ROOF DRAIN REFERENCE REFER TO REINFORCING REQUIRED REVISION ROUGH OPENING ROUND OR DIAMETER SCHEDULE SECTION SQUARE FOOT STOREFRONT SIMILAR SLAB ON GRADE SPECIFICATIONS SQUARE STAINLESS STEEL STAINLESS STEEL STANDARD STEEL STRUCTURAL SYMMETRICAL THICKNESS TOP OF TELEVISION WALL ARM MOUNT TELEVISION CEILING HUNG TELEVISION CEILING HUNG 180 DEGREE SWIVEL TELEVISION ON STAND TELEVISION ON STANDARD WALL MOUNT TYPICAL UNLESS NOTED OTHERWISE VERTICAL VERIFY IN FIELD (PRIOR TO COMMENCEMENT OF WORK) VENT THRU ROOF WELDED WIRE FABRIC WITH WITHOUT WATERPROOFING WATER STOP WEIGHT 1. DO NOT SCALE DRAWINGS - USE DIMENSIONS ONLY. 2. DIMENSIONS WHERE SHOWN ARE NORMALLY GIVEN: A. TO COLUMN CENTERLINE B. TO FINISH FACE OF WALL C. TO FINISH FACE OF EXISTING CONDITIONS 3. DIMENSIONS SHOWN ON LARGER SCALE DRAWINGS GOVERN. 4. FIELD VERIFY ALL EXISTING CONDITIONS. 5. ALL NUMERICAL ELEVATIONS AND LEVELS ARE GIVEN TO THE TOP OF SLAB UNLESS OTHERWISE NOTED. 6. "ALIGN" AS INDICATED ON THE DRAWINGS SHALL BE UNDERSTOOD TO MEAN ALIGN THE FINISH MATERIALS OF THE ELEMENTS INDICATED. 7. ALL INTERIOR GYPSUM WALL BOARD IS 5/8" TYPE "X" GWB ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE. 8. PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK. 9. LOCATIONS AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF THE VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL APPROVE ALL FINAL LOCATIONS OF ACCESS PANELS PRIOR TO INSTALLATION. 10. THERE SHALL BE NO BACK TO BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. 11. ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISHED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE EXCEPTIONS: A. ELECTRICAL CLOSETS D. STAIRS (U.N.O.) B. TELEPHONE CLOSETS E. UTILITY TYPE ROOMS C. MECHANICAL ROOMS 12. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVED FIRE, SMOKE, AND / OR ACOUSTICAL MATERIAL. 13. ALL EXTERIOR WOOD BLOCKING SHALL BE PRESSURE TREATED. 14. ALL VERTICAL AND HORIZONTAL JOINTS SHALL BE STAGGERED A MINIMUM OF 2'-0" ON OPPOSITE SIDES OF GWB PARTITIONS. 15. ARCHITECTURAL DRAWINGS GOVERN AT ALL DIMENSIONS INCLUDING PLACEMENT AND LOCATIONS OF ENGINEERING EQUIPMENT, GRILLES, DUCTS, LIGHTING, ETC. 16. THE CONTRACTOR SHALL NOT DRILL INTO OR CORE THROUGH ANY BEAM OR JOIST, OR CUT THROUGH THE SLAB WITHOUT THE SPECIFIC WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. ALL SUSPENDED EQUIPMENT AND PIPES SHALL BE HUNG BY HANGERS AND ATTACHED TO THE STRUCTURE U.N.O. 17. ALL INTERIOR WOOD USED AS STUDS, BLOCKING OR BRACING SHALL BE FIRE TREATED. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY REINFORCING TO ACCOMODATE INTERIOR FINISHES, MILLWORK, FIXTURES OR EQUIPMENT AS DESCRIBED IN THESE DOCUMENTS. 18. ALL FINISH CARPENTRY AND MILLWORK SHALL BE IN ACCORDANCE WITH THE ARCHITECTURAL WOODWORK INSTITUTE (AWI) STANDARDS FOR SELECTION OF MATERIALS, HARDWARE FABRICATION, WORKMANSHIP, AND FINISHES. UNLESS NOTED OTHERWISE ALL WORK SHALL BE IN "CUSTOM GRADE". 19. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION. OWING TO ANY DISAGREEMENT BETWEEN THE VARIOUS SUBCONTRACTORS OR THE SUBCONTRACTORS AND THE CONTRACTOR AS TO WHERE THE WORK OF ONE BEGINS AND ONE ENDS IN RELATION TO THE WORK OF THE OTHER. 20. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC ACTION. 21. CONTRACTOR IS CAUTIONED THAT THE WORK INVOLVES A NEW BUILDING TO AN EXISTING CAMPUS WHICH WILL REMAIN IN OPERATION DURING CONSTRUCTION. IT IS MANDATORY THAT WORK WHICH IN ANY WAY AFFECTS THE NORMAL OPERATION OF THAT CAMPUS TO BE COORDINATED WITH THE OWNER / USER. EXISTING CONDITIONS 1. WHERE EXISTING CONDITIONS ARE SHOWN, THEY HAVE BEEN DERIVED FROM AVAILABLE DRAWINGS AND REPRESENT THE ARCHITECT'S/ENGINEER'S BEST ESTIMATE OF ACTUAL CONDITIONS. DEPICTED EXISTING CONDITIONS HAVE NOT BEEN CORROBORATED BY FIELD INVESTIGATION. 2. ALL DIMENSIONS AND DETAILS OF EXISTING WORK INDICATED ON THE DRAWINGS SHALL BE FIELD MEASURED AND VERIFIED BY THE GENERAL CONTRACTOR BEFORE PROCEEDING. FIELD CHECKING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. IMMEDIATELY REPORT ANY DISCREPANCIES TO THE ARCHITECT/ENGINEER PRIOR TO THE COMMENCEMENT OF WORK. 3. GENERAL CONTRACTOR IS CAUTIONED THAT THE WORK INVOLVES ADDITION AND OR RENOVATION TO AN EXISTING FACILITY WHICH PART OR ALL OF WILL REMAIN IN OPERATION DURING CONSTRUCTION. IT IS MANDATORY THAT WORK WHICH IN ANY WAY AFFECTS THE NORMAL OPERATION OF THE FACILITY BE COORDINATED WITH THE OWNER/USER. 4. ALL EXISTING INFRASTRUCTURE IN AREAS WHERE NEW WORK WILL BE PERFORMED SHALL BE PROTECTED AS NECESSARY BY THE GENERAL CONTRACTOR THROUGHOUT THE PERIOD OF CONSTRUCTION. BASE FLOOR LINE NOTE: ALL DIMENSIONS AND LOCATIONS ARE TYPICAL UNLESS NOTED OTHERWISE. COORDINATE WITH ELECTRICAL LOCATIONS. 1'-4" C L C L SINGLE OR GANGED LIGHT SWITCHES THERMOSTAT FIRE HORN / STROBE LIGHT (UNLESS CEILING MOUNT IS SPECIFIED) BASE FLOOR LINE CL DUPLEX OUTLET TELEPHONE / DATA OUTLET 1'-6" C L CL 3'-6" 6" 6'-8" ALIGN ELEMENTS ALONG CENTERLINES ADJUST DIMESION AS REQ.D WHERE MASONRY OCCURS TO ALIGN WITHIN COURSING 502.0 A-201 AF-101 1 SIM A 10'-0" FF-01 N A ENTRY LOBBY 1-1101 000000-00 1 VIEW NAME 1/8" = 1'-0" #-- SF99 TRUE NORTH NORTH REFERENCE BUILDING SECTION REFERENCE WALL SECTION REFERENCE INTERIOR ELEVATION REFERENCE DETAIL NUMBER SHEET DETAIL IS LOCATED ON DARKENED POINTS INDICATE SPECIFIC ELEVATION DETAIL NUMBER SHEET ELEVATION IS LOCATED ON DETAIL, SECTION, OR ELEVATION VIEW TITLE DOORS DOORS ARE INDICATED IN ASSOCIATION WITH THE ROOM NUMBER WHICH IT SERVES. IF MORE THAN ONE DOOR SERVES A ROOM, A LETTER DESIGNATION FOLLOWS THE DOOR NUMBER COLUMN DESIGNATION NEW COLUMN ROOM NAME AND NUMBER ROOM NAME ROOM NUMBER DETAIL NUMBER SHEET DETAIL IS LOCATED ON DETAIL REFERENCE DETAIL NUMBER SHEET DETAIL IS LOCATED ON 1-1101A PARTITION TYPE IDENTIFICATION WINDOW IDENTIFICATION DESIGNATES PARTITION TYPE DESIGNATES WINDOW TYPE FURNITURE IDENTIFICATION EQUIPMENT IDENTIFICATION REVISION IDENTIFICATION 1 SCOPE OF REVISION REVISION NUMBER CEILING IDENTIFICATION CEILING TYPE CEILING HEIGHT DESIGNATES TYPE DESIGNATES TYPE 1 AF-101 SIM 1 AF-101 SIM 1 AF-101 SIM 1 BREAK LINE SPOT ELEVATION EXTERIOR ELEVATION REFERENCE 1 1 AF-101 SIM DETAIL NUMBER SHEET ELEVATION IS LOCATED ON N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 5/28/2015 10:57:03 AM G102.1A Checker RF GENERAL INFORMATION MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 ABBREVIATIONS GENERAL ARCHITECTURAL NOTES STANDARD MOUNTING HEIGHTS SYMBOLS LEGEND 6-2-2015 05.28.2015 08/11/15