HomeMy WebLinkAboutG111.1AUP UP MEN'S B112 BOILER (E) XB121 ELECTRIC ROOM (E) XB117A STOR. STAIR G WOMEN'S TOILET STAIR E MEN'S TOILET PANTRY VIDEO CONF. ROOM CONFERENCE ROOM IT OFFICES HOUSE- KEEPING OFFICE STAIR F STAIR: C STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : =156 DOOR EXIT CAPACITY INTERIOR CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 105 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 STAIR: A STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY INTERIOR CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 105 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 92 FT 136 FT 147 FT 118 FT 66 FT OCCUPANT LOAD TABULATION FOR EACH S.C. #L.2 BUSINESS & ASSEMBLY O.L. FACTORS: BUSINESS O.L 1:100 SF GROSS (UNO) ASSEMBLY O.L 1:15 SF NET (UNO) ASSEMBLY USE O.L 1:15 SF NET (UNO) LOWER LEVEL GROSS FLOOR AREA OF S.C.# L.2 = 9,536 SF BUSINESS O.L = 6,348 SF/100 = 64 ASSEMBLY O.L = 2,294 SF/15 = 152 ASSEMBLY USE O.L = 894 SF/15 = 60 TOTAL S.C. #L.2 OCCUPANT LOAD = 276 OCCUPANT LOAD TABULATION FOR EACH S.C. #L.1 BUSINESS O.L. FACTORS: BUSINESS O.L 1:100 SF GROSS (UNO) MECH/STORAGE USE O.L. 1:300 SF GROSS (UNO) LOWER LEVEL GROSS FLOOR AREA OF S.C. # L.1 = 4,860 BUSINESS O.L = 967 SF/100 = 10 MECH/STORAGE O.L = 3,893 SF/300 = 13 TOTAL S.C. #L.1 OCCUPANT LOAD = 23 1 1 1 EXISTING ENCLOSED PARKING OCCUPANCY EXISTING BUSINESS OCCUPANCY EXISTING BUSINESS OCCUPANCY EMERGENCY MAIN ELECTRIC ROOM (E) XB117 CHILLER (E) XB119 A A LIFE SAFETY KEY NOTES FOR LOWER LEVEL 105 105 89 1. NOTE: LOWER LEVEL IS THE ONLY FLOOR AT THE WEST WING WITH NON- SEPARATED MIXED- USE OCCUPANCIES. 1 CENTER LINE OF WEST MEADOW DRIVE DISHWASH (E) WOMEN'S B111 DATA CENTER B110 BOARD ROOM / TRAINING ROOM B115 CONFERENCE ROOM C B116C CONFERENCE ROOM B B116B PROJECT ROOM B114 TR/UPS CLOSET B109 CATERING/STG. B116D 1 AREA OF WORK EXISTING TO REMAIN U.N.O 1 SG 4 5 TO EXIT 3 4 5 2 SG SG 3 3 3 3 TO EXIT TO EXIT 86 FT 2. A- 2 OCCUPANCY, PER IBC 3. A- 3 OCCUPANCY, PER IBC 4. HVAC SHAFT SPACE, OPEN TO MECH ROOM 5. PIT FOR ELEVATORS 1 AND 2 TO SMOKE DOOR F.V.C F.E.C F.E.C F.E.C F.E.C F.E. (E) F.E. (E) F.E. (E) F.E. (E) OUTDOOR PATIO B127 170 FT TO SMOKE DOOR (E) F.V.C (E) CONFERENCE ROOM A B116A 18 107 X .3 = 32.1" 6. EXISTING CAST-IN PLACE CONCRETE FOUNDATION WALL 7. EXISTING WALL STENCILED AS 2HR FIRE BARRIER 7 6 8. PROVIDE INTERIOR AND EXTERIOR SIGNAGE PER IBC 1009.8.2, 1009.9, 1009.10, AND 1009.11, RE: A120A.1A 9. PROVIDE 2-WAY COMMUNICATION, PER IBC 1009.8 RE: A120A.1A 10. NOTE: SOFFIT AT THIS LOCATION IS 36 FEET ABOVE THE PATIO FLOOR 10 8 R 8 9 8 DISCHG = 107 32 35 35 MECH ROOM FIRE SPRINKLER/ MAIN WATER ROOM OFFICE OFFICE OFFICE KITCHEN DRY STORAGE DISH- WASHER DRY STORAGE ELEV. EQUIP. CAFETERIA FIRE EXTINGUISHER AND WALL MOUNTING BRACKET 0 HR FRR SMOKE WALL (PARTITION) (POSITIVE LATCHING DOORS) 1- HOUR FRR SMOKE BARRIER 1- HOUR FRR FIRE BARRIER (45 MIN. DOORS) 2- HOUR FRR FIRE BARRIER (90 MIN. DOORS) WALL RATINGS SG EXISTING SMOKE GUARD AT ELEVATOR OPENING FIELD VERIFY (REMOVE AND REPLACE FOR CEILING WORK) LIFE SAFETY LEGEND S STORAGE ROOM > 100 S.F. MED GAS ROOM, SOILED LINEN ROOM, 1-HR FRR 45 MIN PROTECTED DOORS S1 STORAGE ROOM 50-100 S.F., 0-HR SMOKE WALL (PARTITION). (SELF CLOSING, POSITIVE LATCH DOOR) SMOKE COMPARTMENT BOUNDARY 20 MINUTE DOOR U.N.O. HEALTHCARE CORRIDOR- WITH 0 HR FRR SMOKE WALL(PARTITION) EA. SIDE POSITIVE LATCH DOOR HEALTHCARE SUITE F.E. FIRE EXTINGUISHER AND CABINET F.E.C. FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. EGRESS COMPONENT CAPACITY DIRECTION AND MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT ACCUMULATED OCCUPANCY LOAD TAG EXIT XXX USE GROUPS OCCUPANCIES ASSEMBLY USE A OCCUPANCY IS CONSIDERED I-2 (WHITE) UNLESS OTHERWISE INDICATED PER LEGEND BUSINESS OCCUPANCY FOR BEST LEGIBILITY, THIS SHEET MUST BE VIEWED IN COLOR AMBULATORY HEALTHCARE OCCUPANCY EXIT DISCHARGE TO EXTERIOR PATH ASSEMBLY STORAGE LOCKERS MECHANICAL (20 MIN. SELF- CLOSING/ AUTO CLOSING DOORS, U.N.O) COMBINATION HORIZONTAL EXIT AND 2- HOUR FRR- SMOKE BARRIER (90 MIN. DOORS) NOTE: STAIRS AND SHAFTS ARE SHOWN AS WHITE, REGARDLESS OF OCCUPANCY CONTEXT. OTHER SYMBOLS LIFE SAFETY GENERAL NOTES EXISTING BUILDING INFORMATION FOR THIS LIFE SAFETY PLAN IS BASED UPON INPUTS FROM VARIOUS RECORD DRAWINGS AND SELECTED FIELD CHECKS. NOTIFY ARCHITECT AND OWNER IF CONFLICTING EXISTING INFORMATION IS FOUND DURING DEMOLITION AND/ OR CONSTRUCTION OF THIS PROJECT. BUSINESS EGRESS THROUGH 2- STORY LOBBY (EXISTING CONDITION) BLACK LINES FOR WALLS /PARTITIONS, DOORS, PLUMBING , AND CASEWORK INDICATE AREAS OF NEW WORK. GRAY LINES, LIKE WISE, INDICATE AREAS THAT ARE EXISTING. (NEW) SMOKE GUARD AT ELEVATOR OPENING SG EXISTING. ALSO SEE GENERAL NOTES BELOW (E) FIRE EXTINGUISHERS SPACING ARE BASED UPON 4A SIZE. EXISTING FIRE EXTINGUISHER AND WALL MOUNTING BRACKET F.E. EXISTING FIRE EXTINGUISHER AND CABINET F.E.C. EXISTING FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. (E) (E) (E) EXTERIOR AREA FOR ASSISTED RESCUE R 29 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 9/7/2016 11:56:26 AM G111.1A Checker Author LIFE SAFETY PLAN - LOWER LEVEL - PHASE 1 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 LIFE SAFETY PLAN - LOWER LEVEL - PHASE 1 WEST WING EAST WING CENTRAL WING 6 6 ADD #6 TOV, DFPC 11.16.2015 32 ASI #23 04.08.2016 33 ASI #17 02.01.2016 35 ASI #26 09.07.2016 01/04/17