Loading...
HomeMy WebLinkAboutG112.1AUP UP UP UP CHANGING 1053 MAIL-PLOT-COPY STORAGE 1010 CONFERENCE ROOM 1012 CTRMR OFFICE 1005 ATC FELLOWSHIP DIRECTOR 1004 INC/HOOD A 1019 LAB 1013 OFFICE (1) 1016 OFFICE (1) 1017 OFFICE (1) 1015 OFFICE (1) 1011 OFFICE (2) 1041 PRIV. TREATMENT 1027 VVMC IT 1048 CLOSET 1045 STAFF ROOM 1039 WOMEN'S TLT/ LOCKERS 1043 MEN'S TLT/ LOCKERS 1044 SEMI PRIV. TRMT. 1031 ELEC 1047 SEMI PRIV. TRMT. 1030 EXISTING EMERGENCY MEDICAL SERVICES BUILDING S S S S A A A A A A A A A STAIR: B STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY EXTERIOR CLEAR WIDTH: = 38.5" CAPACITY (38.5"/0.2): = 193 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 119 STAIR: C STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : =156 DOOR EXIT CAPACITY (EXTERIOR) CLEAR WIDTH: = 44.5" CAPACITY (44.5"/0.2): = 222 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 STAIR: A STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : =156 DOOR EXIT CAPACITY (EXTERIOR) CLEAR WIDTH: = 44.5" CAPACITY (44.5"/0.2): = 222 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 EXISTING HEALTHCARE OCCUPANCY EXISTING HEALTHCARE OCCUPANCY EXISTING BUSINESS OCCUPANCY OCCUPANT LOAD TABULATION FOR EACH S.C. #1.2 HEALTH CARE O.L. FACTORS: OUTPATIENT TREATMENT O.L 1:100 SF GROSS (UNO) BUSINESS USE O.L 1:100 SF GROSS (UNO) ASSEMBLY USE O.L. FACTOR 1:15 SF NET (UNO) LEVEL 1 GROSS FLOOR AREA OF S.C.# 1.2 = 6,520 SF OUTPATIENT TREATMENT & BUSINESS O.L. = 6,168 SF/100 = 62 ASSEMBLY USE O.L. = 150 SF/15 = 10 TOTAL S.C. #1.2 OCCUPANT LOAD = 72 OCCUPANT LOAD TABULATION FOR EACH S.C: #1.1 HEALTH CARE O.L. FACTORS: OUTPATIENT TREATMENT O.L 1:100 SF GROSS (UNO) BUSINESS USE O.L. FACTOR 1:100 SF NET (UNO) ASSEMBLY USE O.L 1:15 SF NET (UNO) LOCKERS USE O.L 1:50 SF GROSS (UNO) LEVEL 1 GROSS FLOOR AREA OF S.C.# 1.1 = 15,860 SF OUTPATIENT TREATMENT O.L. = 9,866 SF/100 = 99 BUSINESS USE O.L = 4,397 SF/100 = 44 ASSEMBLY USE O.L. = 1,377/15 = 92 LOCKERS USE O.L = 230 SF/50 = 5 TOTAL S.C. #1.1 OCCUPANT LOAD = 240 134 FT 100 FT 175 FT 74 FT 82 FT 106 FT 123 FT VEST. 1000 S EXISTING 2- STORY LOBBY ADMIN/ LAB SUITE (NON- PATIENT) 4,985 SF, TYP. MICROSCOPY (4) 1014 PHARMACY (E) X1P OFFICE (E) X1O1 FIRE PANEL (E) X1FP MRI (E) X1MRI CONTROL (E) X1C DIR OF EMERGENCY (E) X1D FAMILY CONSULT(E) M1INF TLT (E) X1T STORAGE (E) X1S MRI EQUIP ROOM (E) X1M A MRI SUITE (NON SLEEPING) 1,580 SF, TYP. REHAB SUITE (NON- SLEEPING) 7,890 SF, TYP EXISTING ENCLOSED PARKING OCCUPANCY S S CANOPY ABOVE EXISTING CANOPY ABOVE S1 S LIFE SAFETY KEY NOTES FOR FIRST LEVEL 1. 2. EXISTING HORIZONTAL EXIT (BUSINESS OCCUPANCY) 3. HEALTHCARE OCCUPANTS CAN FIND REFUGE (OR EXIT) AT ADJACENT HEALTHCARE OCCUPANCIES. ALSO, HEALTHCARE OCCUPANTS CAN EXIT THROUGH THE EAST WING. 20 11 114 140 95 26 4 140 OCCUPANT LOAD TABULATION FOR EACH S.C: #1.3 HEALTH CARE O.L. FACTORS: OUTPATIENT TREATMENT O.L 1:100 SF GROSS (UNO) ASSEMBLY USE O.L. FACTOR 1:15 SF NET (UNO) LEVEL 1 GROSS FLOOR AREA OF S.C.# 1.3 = 9,907 OUTPATIENT TREATMENT O.L. = 9,799 SF/100 = 98 ASSEMBLY USE O.L. = 108 SF/15 = 8 TOTAL S.C. #1.3 OCCUPANT LOAD = 106 OCCUPANT LOAD TABULATION FOR EACH S.C: #1.4 HEALTH CARE O.L. FACTORS: OUTPATIENT TREATMENT O.L 1:100 SF GROSS (UNO) ASSEMBLY USE O.L. FACTOR 1:15 SF NET(UNO) LEVEL 1 GROSS FLOOR AREA OF S.C.# 1.4 = 10,177 SF OUTPATIENT TREATMENT O.L. = 9,737 SF/100 = 98 ASSEMBLY USE O.L. = 440 SF/15 = 30 TOTAL S.C. #1.4 OCCUPANT LOAD = 128 STAIR: D STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY (44"/0.3) : =146 DOOR EXIT CAPACITY EXTERIOR CLEAR WIDTH: = 32.5" CAPACITY (32.5"/0.2): = 162 ACTUAL OCCUPANT LOAD AT STAIR: = 113 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 113 PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE CENTER LINE OF WEST MEADOW DRIVE CENTER LI NE OF FRONTAGE ROAD PROPERTY LINE 34'-10" 35'-0" 36'-1 3/8" 39'-1" CHANGING BREAK/SHARED 1022 CHANGING OFFICE (2) 1042 FIRE -SMOKE RATED ACCORDIAN DOOR-STACK @ NORTH; LATCH AT SOUTH. CARDIO- PULMONARY SUITE RESEARCH CLINIC SUITE MRISUITE EMERGENCY DEPARTMENT SUITE 2 3 GIFT SHOP 1 TLT. 1021 OFFICE 1006A OFFICE 1006 OFFICE 1008 MEDICAL RECORDS (10) 1009 OFFICE 1007 FRONT DESK 1046 OFFICE (1) 1040 EQUIP 1037 THERAPIST WORKSTATIONS (13) 1035 DEMARC 1051 CONFERENCE 1018 PRIV. TREATMENT 1028 WHEEL CHAIR STORAGE 1024 PHYSICAL THERAPY TREATMENT AREA 1033 EXERCISE 1036 BIOMOTION LAB 1052 VALET 1001 SEMI PRIV. TRMT. 1030 AREA OF WORK EXISTING TO REMAIN U.N.O INC/HOOD H 1020 TO EXIT 3 4 5 TO SMOKE DOOR SUITE EGRESS SUITE EGRESS TO EXIT TO SMOKE DOOR TO EXIT 167 FT 4 4 4. 4'- 0" WIDE DOOR AT EXTERIOR DISCHARGE, FOR STAIRS 'A' AND 'C'. F.V.C F.E.C F.E.C F.E.C F.E.C F.E. COMMON PATH ELEV 7 ELEV 8 F.V.C (E) F.E. (E) F.E.C (E) TLT 1038 DISCHG = 140 DISCHG = 113 DISCHG = 4 DISCHG = 140 DISCHG = 223 DISCHG = 223 DISCHG = 20 DISCHG = 11 DISCHG = 113 32 MECH 1054 LAB 1013 31 31 34 35 35 35 FIRE EXTINGUISHER AND WALL MOUNTING BRACKET 0 HR FRR SMOKE WALL (PARTITION) (POSITIVE LATCHING DOORS) 1- HOUR FRR SMOKE BARRIER 1- HOUR FRR FIRE BARRIER (45 MIN. DOORS) 2- HOUR FRR FIRE BARRIER (90 MIN. DOORS) WALL RATINGS SG EXISTING SMOKE GUARD AT ELEVATOR OPENING FIELD VERIFY (REMOVE AND REPLACE FOR CEILING WORK) LIFE SAFETY LEGEND S STORAGE ROOM > 100 S.F. MED GAS ROOM, SOILED LINEN ROOM, 1-HR FRR 45 MIN PROTECTED DOORS S1 STORAGE ROOM 50-100 S.F., 0-HR SMOKE WALL (PARTITION). (SELF CLOSING, POSITIVE LATCH DOOR) SMOKE COMPARTMENT BOUNDARY 20 MINUTE DOOR U.N.O. HEALTHCARE CORRIDOR- WITH 0 HR FRR SMOKE WALL(PARTITION) EA. SIDE POSITIVE LATCH DOOR HEALTHCARE SUITE F.E. FIRE EXTINGUISHER AND CABINET F.E.C. FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. EGRESS COMPONENT CAPACITY DIRECTION AND MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT ACCUMULATED OCCUPANCY LOAD TAG EXIT XXX USE GROUPS OCCUPANCIES ASSEMBLY USE A OCCUPANCY IS CONSIDERED I-2 (WHITE) UNLESS OTHERWISE INDICATED PER LEGEND BUSINESS OCCUPANCY FOR BEST LEGIBILITY, THIS SHEET MUST BE VIEWED IN COLOR AMBULATORY HEALTHCARE OCCUPANCY EXIT DISCHARGE TO EXTERIOR PATH ASSEMBLY STORAGE LOCKERS MECHANICAL (20 MIN. SELF- CLOSING/ AUTO CLOSING DOORS, U.N.O) COMBINATION HORIZONTAL EXIT AND 2- HOUR FRR- SMOKE BARRIER (90 MIN. DOORS) NOTE: STAIRS AND SHAFTS ARE SHOWN AS WHITE, REGARDLESS OF OCCUPANCY CONTEXT. OTHER SYMBOLS LIFE SAFETY GENERAL NOTES EXISTING BUILDING INFORMATION FOR THIS LIFE SAFETY PLAN IS BASED UPON INPUTS FROM VARIOUS RECORD DRAWINGS AND SELECTED FIELD CHECKS. NOTIFY ARCHITECT AND OWNER IF CONFLICTING EXISTING INFORMATION IS FOUND DURING DEMOLITION AND/ OR CONSTRUCTION OF THIS PROJECT. BUSINESS EGRESS THROUGH 2- STORY LOBBY (EXISTING CONDITION) BLACK LINES FOR WALLS /PARTITIONS, DOORS, PLUMBING , AND CASEWORK INDICATE AREAS OF NEW WORK. GRAY LINES, LIKE WISE, INDICATE AREAS THAT ARE EXISTING. (NEW) SMOKE GUARD AT ELEVATOR OPENING SG EXISTING. ALSO SEE GENERAL NOTES BELOW (E) FIRE EXTINGUISHERS SPACING ARE BASED UPON 4A SIZE. EXISTING FIRE EXTINGUISHER AND WALL MOUNTING BRACKET F.E. EXISTING FIRE EXTINGUISHER AND CABINET F.E.C. EXISTING FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. (E) (E) (E) EXTERIOR AREA FOR ASSISTED RESCUE R 29 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 9/7/2016 11:56:33 AM G112.1A Checker Author LIFE SAFETY PLAN - LEVEL ONE-PHASE 1 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 LIFE SAFETY PLAN - LEVEL ONE - PHASE 1 SCALE: 1/16" = 1' - 0" 6 6 ADD #6 TOV, DFPC 11.16.2015 31 ASI #17 02.01.2016 32 ASI #23 04.08.2016 34 ASI #25 08.05.2016 35 ASI #26 09.07.2016 31 ASI #22 07.05.2016 32 ASI #23 04.08.2016 34 ASI #25 08.05.2016 35 ASI #26 09.07.2016 01/04/17