Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
G113.1A
DN DN UP UPUP DN UP PATIENT RM 1 2229 PATIENT RM 2 2228 PATIENT RM 3 2227 CATH LAB (E) X2CATH CONTROL (E) X2C CATH LAB STORAGE (E) X2CLS LOCKER (E) X2L DRESSING (E) X2D ELEC (E) X2E STAFF TLT (E) X2T1 PUBLIC TLT (E) X2T2 PED/ CATH/ EXAM (E) X2PED SOILED UTILITY (E) X2SU LINEN (E) X2LN NOURISH (E) X2N ICU/ISO 2220 ICU 1 2221 ICU 2 2222 1 ICU/ 2 SP (E) X2ICU4 1 ICU/ 2 SP (E) X2ICU3 1 ICU/ 2 SP (E) X2ICU2 1 ICU/ 2 SP (E) X2ICU1 2 BED ROOM (E) X2BR12 2 BED ROOM (E) X2BR11 ? ? ? 2 BED ROOM (E) X2BR6 2 BED ROOM (E) X2BR7 2 BED ROOM (E) X2BR8 1 BED ROOM (E) X2BR9 STAFF TLT 2021A TUB ROOM (E) X2TR STAFF LOUNGE/ LOCKERS 2021 CONF ROOM 2022 ICU 4 2224 ICU 3 2223 NORTH NURSE STATION/ICU 2024 CLEAN SUPPLIES 2025 MECH/ CART STORAGE (E) 2019 STORAGE 2020 2 BED ROOM (E) X2BR1 2 BED ROOM (E) X2BR2 EXISTING EMERGENCY MEDICAL SERVICES BUILDING PT/OT STORAGE 2219B A A A A A A S S S S S S1 S STAIR: C STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY (INTERIOR CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 STAIR: B STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 119 STAIR: A STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3): = 156 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 OCCUPANT LOAD TABULATION FOR EACH S.C. #2.1 HEALTH CARE O.L. FACTORS: INPATIENT TREATMENT O.L SLEEPING O.L ASSEMBLY USE O.L. LOCKERS USE O.L LEVEL 2 GROSS FLOOR AREA OF S.C.# 2.1 = 19,384 SF INPATIENT TREATMENT O.L = 1,370 SF/240 = 6 SLEEPING O.L = 17,615 SF/120 = 147 ASSEMBLY USE O.L = 293 SF/15 = 20 LOCKERS USE O.L = 106 SF/50 = 3 TOTAL S.C. #2.1 OCCUPANT LOAD = 176 EXISTING BUSINESS OCCUPANCY EXISTING HEALTHCARE OCCUPANCY 120 FT 183 FT 135 FT 148 FT 97 FT EXISTING CANOPY BELOW LEVEL THREE ABOVE ROOF BELOW PATIENT RM 5 2225 EXISTING ENCLOSED PARKING OCCCUPANCY S1 A EXISTING ROOF BELOW EXISTING BUSINESS OCCUPANCY EXISTING 2-STORY LOBBY EXISTING ROOF BELOW LEVEL THREE ABOVE S1 HSKP (E) X2H S1 SG SG SG SG SG SG EXISTING OR SUITE (NON- SLEEPING) EXISTING STAFF SUPPORT SUITE (NON- PATIENT) A A S1 S1 S1 CANOPY BELOW 1:240 SF GROSS (UNO) 1:120 SF GROSS (UNO) 1:15 SF NET (UNO) 1:50 SF GROSS (UNO) OCCUPANT LOAD TABULATION FOR EACH F.C. #2.1 BUSINESS O.L. FACTORS: BUSINESS O.L 1:100 SF GROSS (UNO ASSEMBLY USE O.L 1:15 SF NET (UNO) MECH/STORAGE O.L 1:300 SF GROSS (UNO) LEVEL 2 GROSS FLOOR AREA OF F.C.# 2.1 = 10,483 SF BUSINESS O.L = 8,796 SF/100 = 88 ASSEMBLY USE O.L = 400 SF/15 = 27 MECH/STORAGE O.L = 1, 287 SF/300 = 5 TOTAL F.C. #2.1 OCCUPANT LOAD = 120 STAIR: D STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY (44"/0.3) : = 146 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 38.5" CAPACITY (38.5"/0.2): = 193 ACTUAL OCCUPANT LOAD AT STAIR: = 113 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 113 OCCUPANT LOAD TABULATION FOR EACH S.C. #2.2 HEALTH CARE O.L. FACTORS: INPATIENT TREATMENT O.L SLEEPING O.L ASSEMBLY USE O.L. LOCKERS USE O.L LEVEL 2 GROSS FLOOR AREA OF S.C.# 2.2 = 12,858 SF INPATIENT TREATMENT O.L = 1,015 SF/240 = 5 SLEEPING O.L = 10,519 SF/120 = 88 ASSEMBLY USE O.L = 954 SF/15 = 64 LOCKERS USE O.L = 370 SF/50 = 8 TOTAL S.C. #2.2 OCCUPANT LOAD = 165 1:240 SF GROSS (UNO) 1:120 SF GROSS (UNO) 1:15 SF NET (UNO) 1:50 SF GROSS (UNO) (BUSINESS OCCUPANCY) LIFE SAFETY KEY NOTES FOR SECOND LEVEL 118 113 118 113 60 60 1 1. HEALTHCARE OCCUPANTS WILL NOT USE BUSINESS FIRE COMPARTMENT FOR REFUGE. CENTER LINE OF WEST MEADOW DRIVE 2 2. FIRE RATING IS NOT REQUIRED, PER IBC TABLE 602, FOOT NOTE H. PATIENT RM 4 2226 3 IT CLOSET 2002 STORAGE 2330 ISOLATION (E) X2ISO 2 BED ROOM (E) X2BR3 2 BED ROOM (E) X2BR4 2 BED ROOM (E) X2BR5 PED/OBS (E) X2PED1 PED/OBS (E) X2PED2 S HOSPITALIST (E) 2012 ANTE 2220A STORAGE (E) X2S AREA OF WORK EXISTING TO REMAIN U.N.O S MEDS 2023 ALCOVE M2A WHEELCHAIR STORAGE ALCOVE M2WC ELEC 2230 S1 TO EXIT TO SMOKE DOOR 3 4 5 TO SMOKE DOOR TO SMOKE DOOR TO EXIT S F.E.C F.E.C F.E.C F.E.C F.E.C F.V.C ELEV 7 ELEV 8 F.V.C (E) F.V.C (E) F.V.C (E) (E) PAT. TLT 2224A PAT. TLT 2223A PAT. TLT 2222A PAT. TLT 2221A PAT. TLT. 2220B 35 35 FIRE EXTINGUISHER AND WALL MOUNTING BRACKET 0 HR FRR SMOKE WALL (PARTITION) (POSITIVE LATCHING DOORS) 1- HOUR FRR SMOKE BARRIER 1- HOUR FRR FIRE BARRIER (45 MIN. DOORS) 2- HOUR FRR FIRE BARRIER (90 MIN. DOORS) WALL RATINGS SG EXISTING SMOKE GUARD AT ELEVATOR OPENING FIELD VERIFY (REMOVE AND REPLACE FOR CEILING WORK) LIFE SAFETY LEGEND S STORAGE ROOM > 100 S.F. MED GAS ROOM, SOILED LINEN ROOM, 1-HR FRR 45 MIN PROTECTED DOORS S1 STORAGE ROOM 50-100 S.F., 0-HR SMOKE WALL (PARTITION). (SELF CLOSING, POSITIVE LATCH DOOR) SMOKE COMPARTMENT BOUNDARY 20 MINUTE DOOR U.N.O. HEALTHCARE CORRIDOR- WITH 0 HR FRR SMOKE WALL(PARTITION) EA. SIDE POSITIVE LATCH DOOR HEALTHCARE SUITE F.E. FIRE EXTINGUISHER AND CABINET F.E.C. FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. EGRESS COMPONENT CAPACITY DIRECTION AND MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT ACCUMULATED OCCUPANCY LOAD TAG EXIT XXX USE GROUPS OCCUPANCIES ASSEMBLY USE A OCCUPANCY IS CONSIDERED I-2 (WHITE) UNLESS OTHERWISE INDICATED PER LEGEND BUSINESS OCCUPANCY FOR BEST LEGIBILITY, THIS SHEET MUST BE VIEWED IN COLOR AMBULATORY HEALTHCARE OCCUPANCY EXIT DISCHARGE TO EXTERIOR PATH ASSEMBLY STORAGE LOCKERS MECHANICAL (20 MIN. SELF- CLOSING/ AUTO CLOSING DOORS, U.N.O) COMBINATION HORIZONTAL EXIT AND 2- HOUR FRR- SMOKE BARRIER (90 MIN. DOORS) NOTE: STAIRS AND SHAFTS ARE SHOWN AS WHITE, REGARDLESS OF OCCUPANCY CONTEXT. OTHER SYMBOLS LIFE SAFETY GENERAL NOTES EXISTING BUILDING INFORMATION FOR THIS LIFE SAFETY PLAN IS BASED UPON INPUTS FROM VARIOUS RECORD DRAWINGS AND SELECTED FIELD CHECKS. NOTIFY ARCHITECT AND OWNER IF CONFLICTING EXISTING INFORMATION IS FOUND DURING DEMOLITION AND/ OR CONSTRUCTION OF THIS PROJECT. BUSINESS EGRESS THROUGH 2- STORY LOBBY (EXISTING CONDITION) BLACK LINES FOR WALLS /PARTITIONS, DOORS, PLUMBING , AND CASEWORK INDICATE AREAS OF NEW WORK. GRAY LINES, LIKE WISE, INDICATE AREAS THAT ARE EXISTING. (NEW) SMOKE GUARD AT ELEVATOR OPENING SG EXISTING. ALSO SEE GENERAL NOTES BELOW (E) FIRE EXTINGUISHERS SPACING ARE BASED UPON 4A SIZE. EXISTING FIRE EXTINGUISHER AND WALL MOUNTING BRACKET F.E. EXISTING FIRE EXTINGUISHER AND CABINET F.E.C. EXISTING FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. (E) (E) (E) EXTERIOR AREA FOR ASSISTED RESCUE R 29 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 9/7/2016 11:56:37 AM G113.1A Checker Author LIFE SAFETY PLAN, LEVEL TWO- PHASE 1 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 LIFE SAFETY PLAN - LEVEL TWO SCALE: 1/16" = 1' - 0" 6 6 ADD #6 TOV, DFPC 11.16.2015 35 ASI #17 02.01.2016 6 ADD #6 TOV, DFPC 11.16.2015 35 ASI #26 09.07.2016 01/04/17