Loading...
HomeMy WebLinkAboutG114.1ADN UP UP UP UP DN UP FS FS FS FS FS FS FS FS FS S SPD - DIRTY SIDE 3054 STERILE SUPPLIES / CASE CARTS 3071 STORAGE 3063 NURSE STATION 3029 1 - PATIENT 3023 TLT/SHWR 3041A STERILE EQUIPMENTSTORAGE 3040 ? ? ? OFFICE 3044 TLT / SHWR 3042A 3-COR-8 BAY 2 - FLEX 3031 BAY 1 - FLEX 3030 OFFICE 3051 OFFICE 3050 OFFICE 3049 OFFICE 3048 CONFERENCE 3046 3-COR-9 SCOPE CLEANING 3056 SPECIMEN FREEZER 3062 I.T. 3004 STAFF TLT 3006 ALCOVE WAITING 3001 OR( E) X3O1 SURGERY SUPPORT(E) X3SS OR(E) X3O4 SURGERY SUPPORT(E) X3SS ANESTHESIA WORKROOM 3065 HANGING VEST STORAGE 3080 SURGERY LOCKERS WOMEN'S 3079 SURGERY LOCKERS WOMEN'S 3079 OR(E) X3O3 SUB-STERILE (E) X3S SCRUB (E) X3S CONTROL / SCHEDULER 3064 OR(E) X3O2 TLT/SHWR 3078A SURGERY LOCKERS MEN'S 3078 SUB-STERILE(E) X3S SCRUB(E) X3S EVS (E) X3EVS 2 - PATIENT 3022 EQUIP. STORAGE 3011 ELECTRICAL 3008 STORAGE ALCOVE CLEAN SUPPLY 3027 MEDS 3026 PAT. TLT 3013 STAFF TLT 3025 EXISTING ROOF BELOW EXISTING ROOF BELOW EXISTING SKYLIGHT A A A A S S S S A S S S S S S S STAIR: C STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 STAIR: B STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : = 156 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 40.5" CAPACITY (41"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 119 STAIR: A STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 47" CAPACITY (47"/0.3) : =156 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 40.5" CAPACITY (40.5"/0.2): = 203 ACTUAL OCCUPANT LOAD AT STAIR: = 119 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 224 135 FT 64 FT 81 FT 144 FT 106 FT EXISTING AMBULATORY HEALTHCARE OCCUPANCY TOP DECK OF EXISTING PARKING OCCUPANCY BAY 3 - FLEX 3032 PATIENT TLT 3028 OFFICE 3005 CONSULTATION 3003 PATIENT TLT 3009 9 - PATIENT/PSP 3015 FAMILY TLT 3002 SOILED UTILITY(E) X3SU BAY 5 3037 BAY 6 3036 BAY 7 3035 BAY 8 3034 BAY 4 3038 MEN'S LOCKERS 3041 NON-STERILE VENDORS 3053 ALCOVE 3055 BREAK DOWN 3058 OFFICE 3059 CLEAN ANTE ROOM 3061 VEST. 3070 3 - PATIENT 3021 4 - PATIENT 3020 5 - PATIENT 3019 6 - PATIENT 3018 7 - PATIENT 3017 8 - PATIENT 3016 NURSE STATION 3024 WOMEN'S LOCKERS 3042 STAFF LOUNGE 3043 A OR STAFF EDUCATOR 3045 TLT/SHWR 3042B SG SG SG SURGERY SUITE (NON- SLEEPING) 8,390 SF, TYP. OFFICE SUITE (NON- PATIENT) 950 SF, TYP. STAFF SUPPORT SUITE (NON- PATIENT) 1,205 SF, TYP. RECOVERY SUITE (NON- SLEEPING) 6,600 SF, TYP. STERILE PROCESS SUITE (NON- PATIENT) 3,015 SF, TYP. S DECONTAMINATION SUITE (NON- PATIENT) 925 SF, TYP. STAIR: D STAIRWAY EXIT CAPACITY STAIRWAY WIDTH: = 44" CAPACITY (44"/0.3) : = 146 DOOR EXIT CAPACITY (INTERIOR) CLEAR WIDTH: = 38.5" CAPACITY (38.5"/0.2): = 193 ACTUAL OCCUPANT LOAD AT STAIR: = 82 ACTUAL OCCUPANT LOAD AT DISCHARGE: = 113 OCCUPANT LOAD TABULATION FOR EACH S.C. #3.1 HEALTH CARE O.L. FACTORS: INPATIENT TREATMENT O.L ASSEMBLY O.L BUSINESS USE O.L. LOCKERS USE O.L LEVEL 3 GROSS FLOOR AREA OF S.C.# 3.1 = 7,267 SF INPATIENT TREATMENT O.L = 4,284 SF/240 = 18 ASSEMBLY USE O.L = 530 SF/15 = 36 BUSINESS USE O.L = 2,117 SF/100 = 22 LOCKERS USE O. L= 336 SF/50 = 7 TOTAL S.C. #3.1 OCCUPANT LOAD = 83 1:240 SF GROSS (UNO) 1:15 SF GROSS (UNO) 1:100 SF NET (UNO) 1:50 SF GROSS (UNO) OCCUPANT LOAD TABULATION FOR EACH S.C. #3.2 HEALTH CARE O.L. FACTORS: INPATIENT TREATMENT O.L ASSEMBLY USE O.L. LOCKERS USE O.L LEVEL 3 GROSS FLOOR AREA OF S.C.# 3.2 = 16,720 SF INPATIENT TREATMENT O.L = 15,759 SF/240 = 66 ASSEMBLY USE O.L = 475 SF/15 = 32 LOCKERS USE O.L = 486 SF/50 = 10 TOTAL S.C. #3.2 OCCUPANT LOAD = 108 1:240 SF GROSS (UNO) 1:15 SF NET (UNO) 1:50 SF GROSS (UNO) OCCUPANT LOAD TABULATION FOR EACH S.C. #3.3 AMBULATORY HEALTHCARE O.L. FACTORS: AMBULATORY HEALTHCARE O.L ASSEMBLY USE O.L. LOCKERS USE O.L LEVEL 3 GROSS FLOOR AREA OF S.C.# 3.3 = 13,213 SF AMBULATORY HEALTHCARE O.L = 12,478 SF/100 = 125 ASSEMBLY USE O.L = 484 SF/15 = 33 LOCKERS USE O.L = 251 SF/50 = 6 TOTAL S.C. #3.3 OCCUPANT LOAD = 164 1:100 SF GROSS (UNO) 1:15 SF NET (UNO) 1:50 SF GROSS (UNO) 82 41 41 118 117 38 LIFE SAFETY KEY NOTES FOR THIRD LEVEL 1. EXISTING SPRINKLED WOOD OVERFRAMING ON CONCRETE ROOF STRUCTURE TO REMAIN, PER NFPA 101. 2. EXISTING FOLDED PLATE CONCRETE ROOF STRUCTURE TO REMAIN. 1 1 2 2 SG SG SG 3 3 3. NOTE: AMBULATORY HEALTHCARE OCCUPANTS CAN FIND REFUGE IN HEALTHCARE SMOKE COMPARTMENT. HEALTHCARE OCCUPANTS WILL NOT USE AMBULATORY HEATHCARE SMOKE COMPARTMENT FOR REFUGE. 160 FT CENTER LINE OF WEST MEADOW DRIVE 29'-6 1/8" 32'-5 3/4" 4. FIRE RATING AT EXTENSION WALL IS NOT REQUIRED, PER 18C TABLE 602, NOTE H. 4 HSKP 3057 10 - PATIENT/ PSP 3014 VESTIBULE 3052 OFFICE ASSISTANT 3047 AREA OF WORK EXISTING TO REMAIN U.N.O HALL OFFICE (E) X3IT STORAGE (E) S 4 STORAGE ALCOVE M3A TO EXIT SUITE EGRESS SUITE EGRESS S S1 S1 TO EXIT 3 4 5 SUITE EGRESS TO EXIT 127 FT F.V.C F.E.C F.E F.E F.E.C F.E.C F.E.C F.E.C F.E F.E F.E.C F.V.C F.E F.E F.E F.E. (E) ELEV 7 ELEV 8 F.E F.V.C F.V.C SOILED HOLDING 3012 HSKP 3010 35 35 35 FIRE EXTINGUISHER AND WALL MOUNTING BRACKET 0 HR FRR SMOKE WALL (PARTITION) (POSITIVE LATCHING DOORS) 1- HOUR FRR SMOKE BARRIER 1- HOUR FRR FIRE BARRIER (45 MIN. DOORS) 2- HOUR FRR FIRE BARRIER (90 MIN. DOORS) WALL RATINGS SG EXISTING SMOKE GUARD AT ELEVATOR OPENING FIELD VERIFY (REMOVE AND REPLACE FOR CEILING WORK) LIFE SAFETY LEGEND S STORAGE ROOM > 100 S.F. MED GAS ROOM, SOILED LINEN ROOM, 1-HR FRR 45 MIN PROTECTED DOORS S1 STORAGE ROOM 50-100 S.F., 0-HR SMOKE WALL (PARTITION). (SELF CLOSING, POSITIVE LATCH DOOR) SMOKE COMPARTMENT BOUNDARY 20 MINUTE DOOR U.N.O. HEALTHCARE CORRIDOR- WITH 0 HR FRR SMOKE WALL(PARTITION) EA. SIDE POSITIVE LATCH DOOR HEALTHCARE SUITE F.E. FIRE EXTINGUISHER AND CABINET F.E.C. FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. EGRESS COMPONENT CAPACITY DIRECTION AND MAXIMUM TRAVEL DISTANCE FROM FURTHEST POINT ACCUMULATED OCCUPANCY LOAD TAG EXIT XXX USE GROUPS OCCUPANCIES ASSEMBLY USE A OCCUPANCY IS CONSIDERED I-2 (WHITE) UNLESS OTHERWISE INDICATED PER LEGEND BUSINESS OCCUPANCY FOR BEST LEGIBILITY, THIS SHEET MUST BE VIEWED IN COLOR AMBULATORY HEALTHCARE OCCUPANCY EXIT DISCHARGE TO EXTERIOR PATH ASSEMBLY STORAGE LOCKERS MECHANICAL (20 MIN. SELF- CLOSING/ AUTO CLOSING DOORS, U.N.O) COMBINATION HORIZONTAL EXIT AND 2- HOUR FRR- SMOKE BARRIER (90 MIN. DOORS) NOTE: STAIRS AND SHAFTS ARE SHOWN AS WHITE, REGARDLESS OF OCCUPANCY CONTEXT. OTHER SYMBOLS LIFE SAFETY GENERAL NOTES EXISTING BUILDING INFORMATION FOR THIS LIFE SAFETY PLAN IS BASED UPON INPUTS FROM VARIOUS RECORD DRAWINGS AND SELECTED FIELD CHECKS. NOTIFY ARCHITECT AND OWNER IF CONFLICTING EXISTING INFORMATION IS FOUND DURING DEMOLITION AND/ OR CONSTRUCTION OF THIS PROJECT. BUSINESS EGRESS THROUGH 2- STORY LOBBY (EXISTING CONDITION) BLACK LINES FOR WALLS /PARTITIONS, DOORS, PLUMBING , AND CASEWORK INDICATE AREAS OF NEW WORK. GRAY LINES, LIKE WISE, INDICATE AREAS THAT ARE EXISTING. (NEW) SMOKE GUARD AT ELEVATOR OPENING SG EXISTING. ALSO SEE GENERAL NOTES BELOW (E) FIRE EXTINGUISHERS SPACING ARE BASED UPON 4A SIZE. EXISTING FIRE EXTINGUISHER AND WALL MOUNTING BRACKET F.E. EXISTING FIRE EXTINGUISHER AND CABINET F.E.C. EXISTING FIRE VALVE CABINET WITH FIRE EXTINGUISHER F.V.C. (E) (E) (E) EXTERIOR AREA FOR ASSISTED RESCUE R 29 000 8' 16" 32" SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/16" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER TOV: C&S PRJ14-0157 B15-0185 (ADD#5) TI PRJ14-0157 B15-0461 E15-0043 (ADD#6) DFPC: C&S 9667 (ADD#5) TI TBD 9/7/2016 11:56:40 AM G114.1A Checker Author LIFE SAFETY PLAN - LEVEL THREE- PHASE 1 02/06/2016 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 LIFE SAFETY PLAN - LEVELTHREE SCALE: 1/16" = 1' - 0" 6 6 ADD #6 TOV, DFPC 11.16.2015 26 ASI #17 02.01.2016 35 ASI #26 09.07.2016 01/04/17