No preview available
HomeMy WebLinkAboutG116.1AF.E.C. (E) REF. REF. REF. CONSTRUCTION AREA L-1 CONSTRUCTION AREA L-2 OCCUPIED AREAS A C WEST WING CENTRAL WING CONSTRUCTION AREA I-2 OCCUPIED AREAS C B A CONSTRUCTION AREA 1-1 WEST WING CENTRAL WING TEMPORARY PUBLIC ENTRY CONSTRUCTION AREA 2-2 OCCUPIED AREAS C B A CONSTRUCTION AREA 2-1 ROOF CONSTRUCTION BELOW WEST WING CENTRAL WING C B A OCCUPIED AREA CONSTRUCTION AREA 3-2 CONSTRUCTION AREA 3-1 WEST WING CENTRAL WING C B A CONSTRUCTION AREA 4-1 (NO OCCUPIED AREAS) WEST WING CENTRAL WING LEGEND AREAS OF ADDED SHELL/ BUILDING CONSTRUCTION CONSTRUCTION ACCESS PUBLIC EGRESS ONE HOUR FIRE-SMOKE RATED CONSTRUCTION BARRIER (W/ 45 MINUTE RATED DOORS) 000 30' 60' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1" = 30' Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 11/16/2015 7:38:56 PM G116.1A Checker Author LIFE SAFETY INTERIM DIAGRAMS- PHASE 1 05/28/2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 1" = 30'-0" 1 LOWER LEVEL- INTERIM SAFETY DIAGRAM 1" = 30'-0" 2 LEVEL ONE- INTERIM SAFETY DIAGRAM 1" = 30'-0" 3 LEVEL TWO- INTERIM SAFETY DIAGRAM 1" = 30'-0" 4 LEVEL THREE- INTERIM SAFETY DIAGRAM 1" = 30'-0" 5 LEVEL FOUR- INTERIM SAFETY DIAGRAM GENERAL NOTES: ALL NEW SHELL SPACE SHALL BE PROTECTED WITH AUTOMATIC SPRINKLER SYSTEM TO COMPLY WITH CURRENT CODES UNTIL FINAL SPRINKLER SYSTEM IS COMPLETED AS PART OF THE TENANT UPFIT. 6 6 ADDENDUM # 6 11.16.2015 7 TOV: TBD 8 DFPC ID: TBD 01/04/17