Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutG116.1AF.E.C.
(E)
REF.
REF.
REF.
CONSTRUCTION
AREA L-1
CONSTRUCTION
AREA L-2
OCCUPIED
AREAS
A
C
WEST
WING
CENTRAL
WING
CONSTRUCTION
AREA I-2
OCCUPIED
AREAS
C
B
A
CONSTRUCTION
AREA 1-1
WEST
WING
CENTRAL
WING
TEMPORARY
PUBLIC ENTRY
CONSTRUCTION
AREA 2-2
OCCUPIED
AREAS
C
B
A
CONSTRUCTION
AREA 2-1
ROOF CONSTRUCTION
BELOW
WEST
WING
CENTRAL
WING
C
B
A
OCCUPIED AREA
CONSTRUCTION
AREA 3-2
CONSTRUCTION
AREA 3-1
WEST
WING
CENTRAL
WING
C
B
A
CONSTRUCTION
AREA 4-1
(NO OCCUPIED AREAS)
WEST
WING
CENTRAL
WING
LEGEND
AREAS OF ADDED SHELL/
BUILDING CONSTRUCTION
CONSTRUCTION ACCESS
PUBLIC EGRESS
ONE HOUR FIRE-SMOKE
RATED CONSTRUCTION BARRIER
(W/ 45 MINUTE RATED DOORS)
000 30' 60'
SCALE:
N
This document is the property of Heery International, Inc. and Heery International Inc. retains all
rights therein, including copyrights. It may only be used in a manner consistent with Heery
International Inc.'s rights while Heery International, Inc. is providing services for the specific project
identified or referred to herein or extensions thereto. It may not be used for any other purpose
except with the express written agreement of, and compensation to, Heery International Inc.
Copyright © 2013 by Heery International, Inc. all rights reserved.
WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42"
drawn by checked by
sheet number
sheet title
item date
date
issued for
seal/signature
consultants/construction managers
owner's project number
project number
1" = 30'
Heery International
555 17th Street, Suite 500
Denver, CO 80202
720.946.0276
OWNER'S PROJECT NUMBER
11/16/2015
7:38:56 PM
G116.1A
Checker
Author
LIFE SAFETY
INTERIM
DIAGRAMS- PHASE
1
05/28/2015
CONSTRUCTION
DOCUMENTS
VAIL VALLEY
MEDICAL CENTER
PHASE 1 - WEST WING
181 WEST MEADOW DRIVE
VAIL, CO
HII-1302604
INTERIOR DESIGN:
Gallun Snow
1920 Market Street,
Suite 240,
Denver, CO 80202 720.407.6002
MECHANICAL, ELECTRICAL,PLUMBING, LOW
VOLTAGE:
Cator Ruma & Associates,Co.
896 Tabor Street,
Lakewood, CO 80401-4700 303.232.6200
CIVIL:
Martin/Martin
225 Main Street,
Unit C101,
Edwards, CO 81632 970.926.6007
LANDSCAPE:
Lime Green Design, Inc.
900 East Louisiana Avenue,
Suite 209,
Denver, CO 80210 303.733.7558
STRUCTURAL:
Structural Consultants Inc.
3400 East Bayaud Avenue,
Suite 300,
Denver, CO 80209 303.399.5154
1" = 30'-0"
1
LOWER LEVEL- INTERIM SAFETY DIAGRAM
1" = 30'-0" 2
LEVEL ONE- INTERIM SAFETY DIAGRAM
1" = 30'-0"
3
LEVEL TWO- INTERIM SAFETY DIAGRAM
1" = 30'-0" 4
LEVEL THREE- INTERIM SAFETY DIAGRAM
1" = 30'-0"
5
LEVEL FOUR- INTERIM SAFETY DIAGRAM
GENERAL NOTES:
ALL NEW SHELL SPACE SHALL BE PROTECTED WITH AUTOMATIC
SPRINKLER SYSTEM TO COMPLY WITH CURRENT CODES UNTIL
FINAL SPRINKLER SYSTEM IS COMPLETED AS PART OF THE TENANT UPFIT.
6
6 ADDENDUM # 6 11.16.2015
7 TOV: TBD
8 DFPC ID: TBD
01/04/17