HomeMy WebLinkAboutM0028150 8150 INDOOR AIR HANDLING UNIT FAN SECTIONS SUPPLY AIR COIL SECTIONS REFRIGERATION HUMIDIFIER UNIT SOUND OCTAVE BAND & CENTER BAND FREQUENCY AIR FILTER SECTIONS UNITSIZE DESIG. AREA MFR & OUTDOOR OUTSIDE AIR ULTIMATE OPERATION NO. CONFIG WHEEL DRIVE RPM MOTORS NO. NET AT ELEV MBH MBH EAT LAT COIL BAND 1 2 3 4 5 6 7 8 FUNCTION AREA MERV-A L W H OPER CONTROL REMARKS DESIG. SERVED MODEL OR AIR CFM STREAM AT ELEV FEET OF FANS/ ROWS DIA. TYPE (BELT/ APPROX. EACH FAN ALL FANS OF SERVICE FACE FEET SENS TOTAL °F °F °F °F COIL FLOW PROP P.D. Hz 63 125 250 500 1000 2000 4000 8000 SF RATING DIRTY (IN) (IN) (IN) WEIGHT INDOOR MINIMUM CFM ESP TSP FANS ROW HIGH (IN) (AF/BI) DIRECT) REQ'D MAX REQ'D MAX VFDS AREA CFM AIR DB WB DB WB GPM EWT GLYCOL (FT HD) UNIT (IN WC) (LBS) CASING (IN WC) (IN WC) BHP HP BHP HP (SF) P.D. (NOTE-B) °F % LOCATION SIZE SIZE (IN WC) AHU-1 WEST WING TEMTROL INDOOR 11,000 SUPPLY 35,000 3.00 7.00 0 0 0 0.0 0 0.0 0.0 0.0 67.5 0 HEATING 1 30,000 0.00 0 0 40.5 ---- 55.0 ---- 0.0 0.0 40% 0.0 NONE INLET 0 0 0 0 0 0 0 0 PRE-FILTER 0.0 8 0.00 0 0 0 0 SEE SPECS AHU-1 ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- ---- RADIATED 0 0 0 0 0 0 0 0 ---- ---- ---- ---- RETURN 28,000 2.00 3.00 0 0 0 0.0 0 0.0 0.0 0.0 30.0 0 COOLING 1 35,000 0.00 0 0 79.2 0.0 55.0 0.0 ---- ---- 40% 0.0 DISCH 0 0 0 0 0 0 0 0 FINAL 0.0 14 0.00 COLUMN HEADING NOTES: COMMON NOTES (APPLIES TO ALL AIR HANDLERS): UNIT SPECIFIC REMARKS: NOTE- A: THESE VALUES REFLECT THE EXPECTED OPERATIONAL CONDITIONS AT INITIAL START-UP (FOR INFORMATION ONLY.) ACTUAL VALUES SHALL BE DETERMINE BY TESTING & BALANCING. > REFER TO ELECTRICAL DRAWINGS FOR POWER 1. PROVIDE 3'-6" INSULATED CURB BY AHU MANUFACTURER. RE: M105A.1A FOR AHU-4 WITH REQUIRED DUCTWORK ROUTED THRU CURB. REQUIREMENTS. 2. HEATING WATER COILS WILL BE PUMPED COILS. > UNIT HEIGHT DOES NOT INCLUDE HEIGHT OF CURB. 3. FLOW MONITORING: PROVIDE FAN ARRAY TOTALIZING SYSTEM WITH CONTROL STATION AND BACNET CONNECTION. NOTE-B: COIL FLOW IS ACTUAL FLOW THROUGH COIL. SYSTEM FLOW IS THE FLOW THROUGH THE CONTROL VALVE. THESE MAY BE DIFFERENT FOR PUMPED COILS. > PROVIDE BASE RAIL OR CURB HEIGHT TO ACCOMMODATE CONDENSATE DRAIN P-TRAP. > PROVIDE SHAFT GROUNDING RINGS FOR EACH BEARING ON MOTORS POWERED THROUGH VARIABLE FREQUENCY DRIVES. > MINIMUM 2-ROW HEATING COIL. > MINIMUM 8-ROW COOLING COIL. 7/15/2015 16:43 P:\VVMC\2014-015 West Wing Expansion & Renovation\Mech Load Calcs\VVMC WW Exports\VVMC WW Exports\[Load Airflow Summary.xls]Sheet1 8150 AIR COOLED CONDENSING UNIT MATCHED COOLING AMBIENT LOW AMBIENT COMPRESSORS SIZE (INCHES) DESIG. MFR. MODEL SYSTEM EER MBH AIR TEMP AIR TEMP TYPE NUMBER NUMBER OPER CONTROL REMARKS COMPONENT AT ELEV °F °F OF CIRCUITS L W H WT (LBS) FEET CU-4 TECHNICAL SYSTEMS 20A4LM60 AHU-4 11.0 754 95 40 DIGITAL SCROLL 2 2 106 102 102 5,600 SEE SPECS ALL REMARKS: 1. REFER TO ELECTRICAL DRAWINGS FOR POWER REQUIREMENTS. 2. UTILIZE R410A REFRIGERANT. 3. PROVIDE LOW SOUND FAN PACKAGE. 7/15/2015 16:43 P:\VVMC\2014-015 West Wing Expansion & Renovation\Mech Load Calcs\VVMC WW Exports\VVMC WW Exports\[Load Airflow Summary.xls]Sheet1 8150 STEAM HUMIDIFIER SCHEDULE AIR FLOW CONDITIONS DUCT AREA AIR BLDG STEAM MAXIMUM DESIG. MFR. MODEL LEVEL SERVICE CFM AT EAT COOLING LEAVING AIR W H VELOCITY PRESS LBS/HR VAPOR CONTROL REMARKS ELEV °F %RH TEMP %RH (IN) (IN) (FPM) (PSIG) ABSORBTION RISE DISTANCE FEET °F (INCHES) H-4 DRI-STEEM ULTRA-SORB LV ROOF AHU-4 30000 48 10% 1.4 60% COORDINATE WITH AHU INTERIOR SIZE 540 5 550 14 SEE SPEC 1 REMARKS: 1. LOCATE ALL RELATED EQUIPMENT IN VESTIBULE. 7/15/2015 16:43 P:\VVMC\2014-015 West Wing Expansion & Renovation\Mech Load Calcs\VVMC WW Exports\VVMC WW Exports\[Load Airflow Summary.xls]Sheet1 This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/16/2015 9:07:02 AM M002 JDD SSS MECHANICAL SCHEDULES MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 2 ADDENDUM #2 07.16.2015 2 08/11/15