Loading...
HomeMy WebLinkAboutM105A-1A1 ACCU 2 ACCU 7 EF 24" BOILER FLUE 12" WATER HEATER FLUE 4 CU 1 CH 84x38 80x24 36x24 14 EF 15 EF 1 EF 2 EF 3 EF 6 EF 8 EF 9 EF 5 EF 4 EF 12 EF 11 EF 2 AHU 3 AHU 84x36 52x56 50x50 84x36 18x18 16x16 14x14 12 18x18 40x20 30x30 18x18 10 EF 48x20 18x18 12x12 22x22 14 62x50 13 EF 4 AHU STAIRS AND PLATFORM RE: ARCH STAIRS AND PLATFORM RE: ARCH 100x40 20x92 PROVIDE HEPA FILTER PROVIDE HEPA FILTER PROVIDE HEPA FILTER 18x12 24x24 20x20 26x26 18x18 52x60 52x56 DOWN DOWN 52x60 DOWN DOWN DOWN 5 CU 36x66 DOWN DOWN ROUTED IN AHU CURB 110x40 DOWN 100x40 DOWN 110x40 84x38 H4 CODE REQUIRED OUTSIDE AIR INTAKE CLEARANCE (TYP.). NO EXHAUST, FLUES, VENTS, ETC. ALLOWED WITHIN THIS AREA. (E)MRI CU (E) MRI CU H9 H9 EXISTING KITCHEN EXHAUST TO BE COORDINATED H5 (TYP.) H7 (TYP.) 2 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 OWNER'S PROJECT NUMBER 7/16/2015 9:07:14 AM M105A.1A JDD SSS HVAC PLAN - ROOF - ZONE A MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER PHASE 1 - WEST WING 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 INTERIOR DESIGN: Gallun Snow 1920 Market Street, Suite 240, Denver, CO 80202 720.407.6002 MECHANICAL, ELECTRICAL,PLUMBING, LOW VOLTAGE: Cator Ruma & Associates,Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 SCALE: 1/8" = 1'-0" ROOF LEVEL HVAC PLAN - WEST WING KEYNOTES H4 CHILLER PRE-PURCHASED, INSTALLED BY CONTRACTOR. H5 PART OF THE TENANT FINISH PHASE. EXHAUST FAN AND ASSOCIATED DUCT SHOWN FOR REFERENCE ONLY. H7 PART OF THE TENANT FINISH PHASE. DUCT SHOWN FOR REFERENCE ONLY. H9 RELOCATED (E) MRI CONDENSING UNIT. REROUTE REFRIGERANT LINES AND COORDINATE WITH NEW ARCHITECTURAL FLOOR PLANS AS REQUIRED. 2 ADDENDUM #2 07.16.2015 08/11/15