No preview available
HomeMy WebLinkAboutP105A-1AK J.2 J H G F E D C B 1 2 3 4 5 7 8 Ae2001 2e1978 3e1978 4e1978 Ce1978 De1978 Ge1978 Je1978 8e2001 7e2001 6e2001 FF 5e2001 4e2001 3e2001 2e2001 1e2001 Be2001Ce2001 4 CU 4"VTR 4"VTR 4"VTR 4"VTR 4"VTR 3" VACUUM PUMP EXH. UP THRU ROOF TERMINATE PER NFPA 99 REQUIREMENTS RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE RIDGELINE 1,780 SQ. FT. 3,132 SQ. FT. 3,106 SQ. FT. 1,603 SQ. FT. 4,722 SQ. FT. 1,816 SQ. FT. 1,678 SQ. FT. 2,244 SQ. FT. 2,962 SQ. FT. CHILLER RTU RTU RTU 4"RD/OD-1 4"RD/OD-1 4"RD/OD-1 4"RD/OD-1 4"RD/OD-1 6"RD/OD-1 6"RD/OD-1 6"RD/OD-1 6"RD/OD-1 4"RD/OD-1 2" VACUUM PUMP EXHAUST TERMINATE ABOVE ROOF PER NFPA 99 REQUIREMENTS 3"VTR 3"VTR 3"SD DN FROM GUTTER FOR MANSARD ROOF. CONTINUOUS GUTTER AT PERIMETER OF MANSARD ROOF. REFER TO ARCHITECTURAL DETAIL. 3"SD DN FROM GUTTER FOR MANSARD ROOF. CONTINUOUS GUTTER AT PERIMETER OF MANSARD ROOF. REFER TO ARCHITECTURAL DETAIL. 3"SD DN FROM GUTTER FOR MANSARD ROOF. 3"SD DN FROM GUTTER FOR MANSARD ROOF. CONTINUOUS GUTTER AT PERIMETER OF MANSARD ROOF. REFER TO ARCHITECTURAL DETAIL. 3"SD DN FROM GUTTER FOR MANSARD ROOF. 3"SD DN FROM GUTTER FOR MANSARD ROOF. This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 5/28/2015 8:11:19 AM P105A.1A Checker Author ROOF LEVEL PLUMBING PLAN - NEW MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER Phase 1 West Wing 181 WEST MEADOW DRIVE VAIL, CO 13026.01 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE: Cator Ruma & Associates, Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, Edwards, CO 81632 970.926.6007 LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, Denver, CO 80210 303.733.7558 SCALE: 1/8" = 1'-0" ROOF LEVEL PLUMBING PLAN - WEST WING 08/11/15