Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutP105A-1AK
J.2
J
H
G
F
E
D
C
B
1 2 3 4 5 7 8
Ae2001
2e1978 3e1978 4e1978
Ce1978
De1978
Ge1978
Je1978
8e2001
7e2001
6e2001
FF
5e2001
4e2001
3e2001
2e2001
1e2001
Be2001Ce2001
4
CU
4"VTR
4"VTR
4"VTR
4"VTR
4"VTR
3" VACUUM PUMP
EXH. UP THRU ROOF
TERMINATE PER
NFPA 99
REQUIREMENTS
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
RIDGELINE
1,780 SQ. FT.
3,132 SQ. FT.
3,106 SQ. FT.
1,603 SQ. FT.
4,722 SQ. FT.
1,816 SQ. FT.
1,678 SQ. FT.
2,244 SQ. FT.
2,962 SQ. FT.
CHILLER
RTU
RTU
RTU
4"RD/OD-1
4"RD/OD-1
4"RD/OD-1
4"RD/OD-1
4"RD/OD-1
6"RD/OD-1
6"RD/OD-1
6"RD/OD-1
6"RD/OD-1
4"RD/OD-1
2" VACUUM PUMP EXHAUST
TERMINATE ABOVE ROOF PER
NFPA 99 REQUIREMENTS
3"VTR
3"VTR
3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
CONTINUOUS GUTTER AT
PERIMETER OF MANSARD
ROOF. REFER TO ARCHITECTURAL
DETAIL.
3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
CONTINUOUS GUTTER AT
PERIMETER OF MANSARD
ROOF. REFER TO
ARCHITECTURAL DETAIL. 3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
CONTINUOUS GUTTER AT
PERIMETER OF MANSARD
ROOF. REFER TO ARCHITECTURAL
DETAIL. 3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
3"SD DN FROM
GUTTER FOR
MANSARD ROOF.
This document is the property of Heery International, Inc. and Heery International Inc. retains all
rights therein, including copyrights. It may only be used in a manner consistent with Heery
International Inc.'s rights while Heery International, Inc. is providing services for the specific project
identified or referred to herein or extensions thereto. It may not be used for any other purpose
except with the express written agreement of, and compensation to, Heery International Inc.
Copyright © 2013 by Heery International, Inc. all rights reserved.
WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42"
drawn by checked by
sheet number
sheet title
item date
date
issued for
seal/signature
consultants/construction managers
owner's project number
project number
Heery International
555 17th Street, Suite 500
Denver, CO 80202
720.946.0276
5/28/2015 8:11:19 AM
P105A.1A
Checker
Author
ROOF LEVEL
PLUMBING PLAN -
NEW
MAY 28,
2015
CONSTRUCTION
DOCUMENTS
VAIL VALLEY
MEDICAL CENTER
Phase 1 West Wing
181 WEST MEADOW DRIVE
VAIL, CO
13026.01
STRUCTURAL:
Structural Consultants Inc.
3400 East Bayaud Avenue,
Suite 300,
Denver, CO 80209 303.399.5154
MECHANICAL, ELECTRICAL,
PLUMBING, LOW VOLTAGE:
Cator Ruma & Associates, Co.
896 Tabor Street,
Lakewood, CO 80401-4700 303.232.6200
CIVIL:
Martin/Martin
225 Main Street,
Unit C101,
Edwards, CO 81632
970.926.6007
LANDSCAPE:
Lime Green Design, Inc.
900 East Louisiana
Avenue,
Suite 209,
Denver, CO 80210
303.733.7558
SCALE: 1/8" = 1'-0"
ROOF LEVEL PLUMBING PLAN - WEST WING
08/11/15