Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S105A.1A
ROOF FRAMING PLAN - LEVEL 5 - ZONE A S105A.1A 12/18/2015 This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 CDT APC OCTOBER 12, MAY 28, 2015 CONSTRUCTION DOCUMENTS VAIL VALLEY MEDICAL CENTER Phase 1 West Wing 181 WEST MEADOW DRIVE VAIL, CO HII-1302604 STRUCTURAL: Structural Consultants Inc. 3400 East Bayaud Avenue, Suite 300, Denver, CO 80209 303.399.5154 MECHANICAL, ELECTRICAL, PLUMBING, LOW VOLTAGE: Cator Ruma & Associates, Co. 896 Tabor Street, Lakewood, CO 80401-4700 303.232.6200 CIVIL: Martin/Martin 225 Main Street, Unit C101, LANDSCAPE: Lime Green Design, Inc. 900 East Louisiana Avenue, Suite 209, 303.733.7558 Edwards, CO 81632 Denver, CO 80210 12/18/2015 14-011-05 16 S301 AA.1 4.5 4.5 F.4 G.1 A.4 A.4 AA K K J J H H G G F F E E D D C C B B A A 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 13 S301 C S105A.1A 1.6 1.5 1.1 3 S300 8 S304 3 S304 D 8 ELEVATOR MECHANICAL ROOM PLAN 18/" = 1'-0" A 6 G F 7 AHU-4 MECHANICAL PLATFORM PLAN 18/" = 1'-0" B K J 8 7 18/" = 1'-0" C 4 ASI NO. 6 12.18.2015 3 3 ADDENDUM #4 TOV: B15-0185 DFPC ID: 9667 09.21.2015 8-12-2015 ADDENDUM NO. 3 2 1 ADDENDUM NO. 1 6-26-2015 2'-418/" 3'-678/" 55'-5" 15'-11" 9'-11" 35'-612/" 25'-1112/" 12'-1012/" 19'-712/" 5'-3" 26'-412/" 53'-2" 10'-0" 4'-0" 9'-0" 9'-0" 9'-0" 3'-1112/" 1'-6" 164'-512/" 1'-0" 1'-3" 1'-0" 6" 12'-3" 3'-1" 7" 1'-978/"_ 186'-5" 1'-6" 6'-11" 6'-3" 6'-212/" 2'-0" 4'-11" 3'-912/" 3'-7" 5'-1" 5'-7" 7" 9'-3" 9'-7" 3'-234/" 20 S304 7 S303 7 S303 5 S306 SIM. 5 S301 5 S301 W12X14 W24X55 W24X55 W10X12 W12X14 W16X26 W21X44 W10X12 W12X14 W21X44 W14X22 W14X22 6'-0" 4 3 6'-812/" 13'-312/" 4'-1112/" 20'-0" 10'-0" 24'-1112/" 10'-6" 14'-6" 4'-4" 20'-8" 25'-0" 9'-8" 3 3 TYP. EACH END 1 S305 53'-7" 24'-1112/"_ 11" 6'-11" TYP. 11 S301 CANOPY RE: 7/S301 W10X12 W24X68 W18X35 W21X44 W16X26 W21X44 W18X35 W12X14 W12X14 HSS4X4X12 / HSS4X4X12 / SHAFT 10'-8" 1'-6" 1'-6" 4'-9" 25'-1112/"_ 26'-0"_ 26'-0"_ 11'-2"_ 13'-912/"_ 10'-012/"_ 24'-1112/"_ 1'-6" 1'-6" 1'-6" 3'-10" 7" 7" 2 5 S301 5 S301 TIEBACK W16X26 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W18X35 W24X68 W24X62 ROOF FRAMING PLAN - LEVEL 5 - ZONE A 18/" = 1'-0" 10'-8" 1'-3" 7" 1'-6" 5'-1012/" 1'-6" 1'-0" 7" 4 5 S301 W10X12 W10X12 W10X12 W16X26 W12X14 7" 24'-1112/"_ 10'-178/" 59'-312/" 101'-038/" 6'-3" 104'-4" 25'-0"_ 171'-612/" 8'-4" 8'-4" 8'-4" 6'-1178/" 6'-3" 3" 6'-2" 6" 5'-2" 11'-512/" 5'-0" 2'-6" 712/" 1'-0" 2'-8" 4'-612/" 2'-8" 2'-8" 2'-6" SIM. TYP. W10X12 12 S301 STAIR DESIGN BY OTHERS STAIR DESIGN BY OTHERS W24X68 W24X146 W10X12 W14X22 W18X35 6" 5'-4" 6'-5" 6'-5" 6'-6" 6'-6" 6'-6" 6'-6" 6'-5" 6'-5" 6'-4" 4'-8" 2'-2" 6'-2" 6'-138/" 6'-418/" 6'-4" 5'-012/" 5'-0" 6'-4" 6'-4" 6'-2" 6'-112/" 6'-6" 1'-0" 10'-0" NOTE #13 NOTE #13 STAIRS BY OTHERS 20 S300 W12X26 W24X68 W24X76 W10X12 W10X12 W21X50 W10X12 W24X68 W24X68 6'-734/" 7'-8" 5'-4" 5" 8'-2" 5" FAN (250 LBS) W16X31 W16X31 W16X31 W16X31 W12X14 W16X31 W16X31 W10X12 W24X68 1'-6" 7" 6'-414/" 4'-3" 6'-1012/" 6'-1012/" 6'-512/" W12X26 CANOPY RE: 7/S301 5 S301 SIM. 2 S301 W10X12 W10X12 W10X12 W10X12 W12X26 W16X31 W18X35 W24X76 1'-0" 9'-0" 1'-10" 5" 3'-0" 5" 1'-0" 5'-912/" 5'-9" 5'-9" 6'-4" 2'-4" TYP. 11 S301 C12X20.7 EACH SIDE OF MECH. SCREEN POST W16X31 W14X22 W10X12 W12X14 W12X14 W24X62 W24X68 W14X22 W10X12 W24X62 W24X68 W24X94 W24X68 W24X68 HSS8{8{a MECHANICAL SCREEN POST 6'-6" 6'-6" 6'-6" 6'-6" 7'-8" 6'-6" 6'-6" 6'-6" 6'-6" 7'-8" 2 S301 W14X22 W14X22 W12X26 W12X26 W12X26 W14X22 W12X26 W12X26 W14X22 W12X26 W21X50 W14X22 W21X50 W24X68 3'-412/" W16X31 W10X12 W24X68 W10X12 W10X12 W24X68 W24X68 W10X12 W10X12 W24X104 W24X104 W24X68 W24X68 AHU-2 (80,000 LBS) 154'-212/" 6'-6" 1'-5" 6'-10" FAN (300 LBS) 1 S301 W24X76 W10X12 HSS12X8X14 /W12X26 W14X22 W18X35 ELEVATOR ELEVATOR HSS6X6X12 / HSS6X6X12/ D2 SHAFT 4'-512/" $ COLUMN 5'-1058/" 5'-3" 5'-3" 6'-6" 4'-2" 2'-012/" 2'-4" 4'-1012/"2'-6" 7" 2'-6" 5'-712/" 2'-658/" 5 S304 TYP. 4 S300 TYP. 15 S301 FAN (250 LBS) HSS6X6X12 / W12X26 W21X50 W12X26 W18X35 W12X14 W10X12 W18X35 W24X68 W24X76 W18X35 W12X14 W12X26 HSS6X6X14 /(153'-2") W10X12 W12X26 TYP. 19 S304 W18X35 HSS8X8X14 / 6'-4" 6'-8" 6'-10" 6'-4" 1'-1114/" 512/" 6'-1078/" 1'-1012/" STAIR DESIGN BY OTHERS FAN (250 LBS) FAN (250 LBS) W10X12 W10X12 W10X12 W10X12 W12X26 W18X35 W16X31 W12X26 W16X31 W24X68 W16X31 W24X94 W24X94 W12X26 6'-10" 6'-4" SIM. 1 S301 W24X68 W18X35 W16X31 8'-2" 5'-10" 5'-10" 5'-10" 5'-10" 5'-10" 5'-10" 6'-3" 6'-3" 6'-3" 6'-212/" 4'-9" 2'-10" (200 LBS) FAN (300 LBS) FAN (1000 LBS) STAIRS BY OTHERS W18X35 W16X31 W16X31 W16X31 W16X31 W16X31 W16X31 W24X68 W18X40 W24X68 W16X31 W14X22 W16X26 W24X68 W10X12 W10X12 W24X62 W10X12 W10X12 W24X68 W24X68 W10X12 AHU-3 (85,000 LBS) 154'-212/" 7" 7" 2'-1034/" 7'-8" 5'-7" 5'-7" 1'-6" 6'-0" 8'-2" 6'-6" 1'-6" 4'-7" 4'-7" 1'-6" NOTE #13 SIM. 12 S301 W16X26 W18X35 W18X35 W18X35 W10X12 W24X103 W16X26 4'-10" 1'-6" 1'-0" 5'-212/" 6" 3'-4" 6" 14'-6" 1'-0" NOTE #13 W16X31 W10X12 W12X14 W12X14 W10X12 W12X14 W24X104 6'-3" 6'-3" 6'-3" 6'-212/" 6'-3" 6'-3" 2'-2" 11" 2'-6" 1'-512/" 2'-2" 1'-10" 2'-6" 912/" (200 LBS) FAN (500 LBS) W14X22 W16X26 W16X26 W21X50 W24X68 W14X22 6" 5'-2" 6" 512/" 2'-4" 6" 5'-2" 6" 1'-0" 9'-4" 2'-10" 10" W10X12 W10X12 W12X14 W12X14 W24X68 W24X76 W18X40 W18X40 W24X68 W18X35 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W18X40 W18X40 W10X12 W24X117 1'-0" 2'-1012/" 3'-5 12/" 5'-012/" 5'-012/" 3'-012/"2'-1012/" 5'-2" W12X14 W10X12 W24X68 W24X68 W10X12 W12X14 W12X14 CH-1 (40,000 LBS) 154'-212/" CU-4 (5,600 LBS) 154'-212 / " AHU-4 (55,000 LBS) 154'-212/" 1'-0" 1'-0" 6'-5" 4'-7" 4'-7" 5'-3" 5'-3" 5'-312/" 1'-0" TYP. 14 S304 NOTE #13 W24X68 TYP. W12X14 W24X68 W16X31 W24X68 W24X84 W24X62 W10X12 W10X12 W14X22 W16X26 W16X26 W16X26 W16X31 5'-1112/" 1'-0" 6'-5" 9'-2" 5'-3" 5'-3" 5'-312/" 1'-0" 1'-0" CONDENSING UNIT (600 LBS) W12X14 W10X12 W24X68 W24X94 W24X76 W16X31 W24X68 W21X44 W16X31 W16X26 7'-0" 8'-6" 4'-0" 4'-0" 5'-4" 6" 3'-4" 6" 1'-0" 1'-0" 1'-0" 2'-6" 2'-6" 7" 1'-0" W12X26 HSS4X4X14 / HSS4X4X14 / W24X94 W16X31 W24X68 W10X12 W10X12 W10X12 W10X12 W10X12 W10X12 W16X26 W16X26 W18X40 W18X40 W16X31 W10X12 W10X12 1'-1" 5'-0" 3'-112/" 5" 5'-0" 3'-112/" 8'-6" 8'-0" 5'-4" 4'-0" 5" 3'-0" 5" 912/" 9'-0" 812/" 1'-0" 1'-0" 1'-0" 4'-2" 1'-0" 312/" 2'-10" 1'-0" 3 RE: 10/S306 FOR LIGHT BOOM SUPPORT HSS4X4X14 / HSS4X4X14 / W24X176 W16X26 W16X26 W24X68 W24X94 W18X40 W18X40 W21X44 W10X12 W12X14 W10X12 W10X12 W10X12 878/"26'-0"_ 26'-612/" 6'-5" 6'-5" 4'-812/" 2'-212/" NOTE #16 W24X146 W24X55 W18X35 W18X35 W24X55 W10X12 W16X31 W16X31 W18X35 W12X16 W18X35 W24X55 W10X12 W12X14 W10X12 W16X26 W18X40 W16X26 W16X31 5'-5" 1'-5" 7'-9" 5'-1058/" 10'-6"_ 26'-0"_ 40'-1158/" 6'-10" 6'-4" 1'-5" 1'-5" 6'-10" 6'-4" 2 W18X35 1 S301 W12X26 W12X26 W18X35 W24X68 W18X40 W18X35 2'-712/" 1'-6" 7'-2" 7" 10'-012/"_ 26'-712/" 5'-012/" 1'-0" NOTE #13 W24X68 W24X68 6 S306 W24X68 FAN (700 LBS) FAN (300 LBS) 5 S301 W16X26 W10X12 W10X12 W10X12 W12X26 W16X26 W18X35 W24X68 W24X117 W10X12 W10X12 W10X12 W16X26 W24X68 W10X12 4'-0" 4'-6" 4'-6" 4'-6" 4'-6" 4'-4" 1'-6" 7" 912/" 1012/" 6'-5" 4'-7" 4'-7" 5'-3" 5'-3" 5'-312/" 2'-812/" 1'-0" 1'-0" 6'-5" 2 2 11'-2"_ 13'-912/"_ 6'-012/" 2'-1112/" 5'-412/" 3'-712/" 4'-8" 4'-4" 4'-0" 5'-0" 2'-112/" 5'-3" 5'-3" 7'-0" 5'-4" 1'-0" 2'-0" 2'-4" TYP. 11 S301 W10X12 W10X12 24'-1112/"_ 16'-7" 24'-1112/" 1" $ COLUMN 7'-512/" 5'-618/" 6'-3" 5'-812/" 8'-0" 5 S304 1 S304 HSS6X6X12 / HSS6X6X12 / HSS6X6X12 / HSS6X6X12 / HSS4X4X12 / HSS4{4{a HANGING COLUMN HSS4{4{a HANGING COLUMN 15'-7" 4'-5" 8'-6" 9'-1012/" 13'-6" 9'-1012/" 63'-4" 20'-0"_ 7" 1'-2" 7" 6'-3" 6'-3" 5'-9" 5'-9" 2 DOWN TYP. 1 S304 6 S304 4 S304 1 S304 5 S304 STAIRS BY OTHERS STAIR DESIGN BY OTHERS ELEVATOR W16X26 W18X35 W24X68 W14X22 W10X12 W10X12 W14X22 W14X22 W24X76 W12X14 W12X14 W10X12 W24X55 W10X12 W12X14 W10X12 W16X26 W18X35 W24X62 W24X68 W24X68 W24X68 W16X26 W10X12 W14X22 W10X12 W24X103 W24X103 W12X14 HSS4X4X12/ 154'-012/" HSS4X4X14 / HSS6X6X12 / HSS6X6X12 / 6'-3" 6'-3" 6'-212/" 7" 6'-212/" 5'-512/" 1'-712/" 3'-7" SIM. TYP. U.N.O. 1 S304 13 S301 6" 6'-0" 1'-4" 5'-618/" 6'-3" 5'-812/" 5" 5'-618/" 6'-3" 5'-812/" 6'-0" 1'-6" 1'-438/" 1'-0" 7" DOWN TYP. 15 S301 W16X26 W24X55 W10X12 W10X12 6'-812/"_ 13'-312/"_ 4'-1112/"_ 2 10'-0"_ 3 2 S304 25'-0"_ 2'-2" NOTE #16 7 S304 16 S304 W24X104 W24X146 W12X19 W24X103 W24X55 ROOF DRAIN RE: ARCH. FAN (250 LBS) FAN (500 LBS) FAN (1,500 LBS) FAN (500 LBS) FAN (1,200 LBS) W16X26 TIEBACK TIEBACK W18X35 W24X104 W16X31 W16X31 W18X35 W18X35 W24X146 W24X104 W16X31 W24X68 W18X35 W12X16 W14X22 6" 8'-312/" 8'-4" 7'-6" 1012/" 2'-0" 3'-412/" 2'-0" 8'-312/" 8'-4" 7'-6" 3'-8" 5'-0" NOTE #16 25'-0"_ TYP. AT HANGING COLUMNS TYP. 8'-1"_ 938/" 1'-112/" 7'-1112/" 7" 3'-358/" 9'-8"_ 3'-1"_ 8'-312/" 8'-4" 7'-6" 1'-11" 3'-6" 3'-6" 11" 3 2 ABOVE STRIP WINDOW CANOPY RE: 7/S301 W16X31 W16X31 W24X68 W18X35 4'-6" 7'-7" 4'-6" TYP. STAIR DESIGN BY OTHERS W12X14 W10X12 W12X14 W14X22 W16X26 W10X12 W14X22 158'-212/" D1 5" 5'-5" 13'-912/" 5" 7" 11'-6" 5" 12'-11" 5" 5'-5" 12'-1112/" 5" 19'-212/" 5" 7'-5" 2'-6" 22'-6" 25'-0" 24'-1112/" 12'-712/" 7'-0" 5'-4" STAIR DESIGN BY OTHERS GALVANIZED STEEL GRATING W/ 200 PSF LIVE LOAD CAPACITY C12X20.7 C12X20.7 C12X20.7 C12X20.7 1112/" 1'-112/" 6'-412/" 24'-1112/"_ TIEBACK W21X44 W21X44 W21X44 W16X26 W21X44 W16X26 W16X26 W21X44 W18X35 W24X104 W18X35 W16X26 W16X26 8'-4" 8'-312/" 5'-0" 1'-0" 1'-6" 7" 1'-0" 1'-0" 1'-6" TIEBACK W24X104 W21X44 W21X44 W16X26 W16X26 W16X26 W16X26 W21X44 5'-658/" 938/" 3'-812/" 4'-3" 1'-6" 7" 9'-8" NOTE #16 HSS4{4{a HANGING COLUMN HSS4{4{a HANGING COLUMN 3 2 CANOPY RE: 7/S301 09/13/2016 01/04/17