Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B07-0192
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ NEW (SFR,P/S,DUP) PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ OWNER DAYTON, JOHN W. & ARLENE J. 06/27/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ CONTRACTOR GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ Desciption: DEMO AND BUILD A NEW SFRഀ Occupancy Typeഀ Totals...ഀ Permit B07-0192ഀ Project PRJ06-0162ഀ Statusഀ ISSUEDഀ Applied..:ഀ 06/27/2007ഀ Issued .ഀ 08/06/2007ഀ Expires.....:ഀ 02/02/2008ഀ Phone: 845-5656ഀ Phone: 845-5656ഀ U~ 0A 3ഀ Factor Sq Feet Valuationഀ 8,200 $3,000,000.00*ഀ Number of Dwelling Units: 1ഀ Town of Vail Adjusted Valuation: 3,000,000.00ഀ Revision Valuation: $0.00ഀ a**«»++sr*r:+sr***»****+*********►********+****+***+*****x FEE SUMMARYഀ Building > $12, 906.75 Restuarant Plan Review--> $0.00 Total Calculated Fees----->ഀ $22,532.44ഀ Plan Check $8,390.69 Recreation Fee------------ > $1,230.00 Additional Fees >ഀ $0.00ഀ Investigation-> $0.00 TOTAL FEES > $22,532.44 Total Permit Fee----------->ഀ $22,532.44ഀ Will Call-----> $3.00 Payments >ഀ $22,532.44ഀ BALANCE DUE--------- >ഀ $0.00ഀ ~****»►*r**s*t*****~r****r****r*****r*******~****+**~s***~s*****~r*r►***w**x►**~******+►«**►+**+►~~*****~**►**+►~*+*~~~~+►++s***~r***r**~*+++**srഀ Approvals:ഀ Item: 05100 BUILDING DEPARTMENTഀ 08/01/2007 cgunion Action: COND see conditionsഀ Item: 05400 PLANNING DEPARTMENTഀ 07/21/2007 bgibson Action: AP office set routed to G-1ഀ Item: 05600 FIRE DEPARTMENTഀ 07/03/2007 JJR Action: AP See conditions.ഀ Perimeter exceeds 3001.ഀ Landscape features prevent fire department access.ഀ Fire sprinkler system and fire alarm system required.ഀ Item: 05500 PUBLIC WORKSഀ 08/02/2007 gc Action: COND see conditionsഀ Item: 05550 ENGINEERING CIVILSഀ See the Conditions section of this Document for any conditions that may apply to this permit.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAN'gE ~T PHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AMഀ 4 PM. 1 YOഀ SIGNATURE OF10WNER OR CONTRACTOR FOR HIMSELF AND OWNERഀ ഀ CONDITIONS OF APPROVALഀ Permit B07-0192 as of 08-06-2007 Status: ISSUEDഀ ഀ Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 06/27/2007ഀ Applicant: GEORGE SHAEFFER CONSTRUCTION Issued: 08/06/2007ഀ Job Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Parcel No: 210107113012ഀ ഀ CONDITIONSഀ ഀ Cond: 33ഀ (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALLഀ BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ Cond: CON0009117ഀ Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFESഀ standards.ഀ Cond: CON0009119ഀ Monitored fire alarm system required and shall comply with NFPA 72(2002) andഀ VFES standards.ഀ Cond: 18ഀ (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC ORഀ SECTION 1009 OF THE 2003 IBC.ഀ Cond: 19ഀ (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTIONഀ 1012 OF THE 2003 IBC.ഀ Cond: 34ഀ (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTINGഀ INSPECTION WILL BE CALLED FOR.ഀ Cond: 39ഀ (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310ഀ OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.ഀ Cond: CON0009183ഀ PROPOSED FIREPLACE IS NOT APPROVED. FIREPLACES SHALL COMPLY WITH IRC R1003ഀ MASONRY FIREPLACE CONSTRUCTION REQUIREMENTS, OR BE A FACTORY BUILT UNITഀ COMPLYING WITH IRC R1004 AND UL127.ഀ Cond: CON0009189ഀ Provide stamped PE drawings of retaining walls with factor of safty, designഀ perameters and assumptions.ഀ Entry: 08/02/2007 By: gc Action: APഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number:ഀ R070001440 Amount: $16,514.2508/06/200710:24 AMഀ Payment Method:ഀ Check Init: DDGഀ Notation: George Shaefferഀ 89921ഀ ഀ Permit No:ഀ ഀ B07-0192 Type: NEW (SFR,P/S,DUP) PERMITഀ Parcel No:ഀ 2101-071-1301-2ഀ Site Address:ഀ 344 BEAVER DAM RD VAILഀ Location:ഀ 344 BEAVER DAM RDഀ Total Fees: $22,532.44ഀ This Payment:ഀ $16,514.25 Total ALL Pmts: $22,532.44ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Codeഀ Description Current Pmtsഀ ഀ BP 00100003111100ഀ ഀ BUILDING PERMIT FEES 12,908.75ഀ PF 00100003112300ഀ PLAN CHECK FEES 2,372.50ഀ RF 11100003112700ഀ RECREATION FEES 1,230.00ഀ WC 00100003112800ഀ ഀ WILL CALL INSPECTION FEE 3.00ഀ ഀ 10-15-2009 Inspection Request Re Forting Page 1 4:25 pm Vim, GO - City O Requested Inspect Date: Friday, October 16, 2009 Inspection Area: CG Site Address: 344 BEAVER DAM RD VAIL 344 BEAVER DAM RD A/P/D Information Activity: B07-0192 Type: B-BLD Sub Type: NSFR Status: ISSUED Const Type: 101 Occupancy: Use: V-B Insp Area: CG Owner: DAYTON, JOHN W. & ARLENE J. Contractor: GEORGE SHAEFFER CONSTRUCTION Phone: 845-5656 Description: DEMO AND BUILD A NEW SFR Requested Inspection(s) Item: 540 BLDG-Final C/O Requested Time: 08:00 AM Requestor: GEORGE SHAEFFER CONSTRUCTION Phone: 845-5656 Comments: 390-5605 Assigned To: CGUNION Entered By: JMONDRAGON K Action: Time Exp Comment: ~Rzu-W U I E-EABELS REQUIRED 01 UIIDTZS BETWEEN MECHANICAL ROOM AND GARAGE AND RC AWL SPACE 2 PULL GRADE AWAY FROM SIDING AT REAR OF HOUSE 6" MIN. 3 PUBLIC WORKS FINAL IS REQUIRED 01 U 42 S Inspection History / Item: 10 BLDG-FOOTING "Approved" 09/14/07 Inspector: GCD Action: PI PARTIAL INSPECTION Comment: SOILS REPORT RECEIVED. FOOTINGS AND 2 IN FOOTING PADS AS HILITED ON PLANS 10/26/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: ALL INTERIOR PADS AND FOOTINGS. 11/09/07 Inspector: GCD Action: CR CORRECTION REQUIRED Comment: 1.PADS AT END OF FOOTINGS REQD TO BE 17" DEEP 2.SECTION 1-S201 DOWEL REQD TO ALTERNATE 3.REMOVE MUD FROM WEST SECTION OF FOOTING 11/12/07 Inspector: dplace Action: AP APPROVED Comment: drill and pin garage footing into house footing. site wall was also checked and builder was told not to ues round rocks to holdup footings. 03/27/08 Inspector: shahn Action: AP APPROVED Comment: SPA REBAR OK. 04/25/08 Inspector: GCD Action: CR CORRECTION REQUIRED Comment: 1.REMOVE SNOW FROM FOOTING 2.DOWELS REQD TO BE 1'4" OC NOT ENOUGH DOWELS ON JOB. 04/28/08 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: CORRECTIONS FROM 04-25-08 FOR FOOTING APPR. 05/21/08 Inspector: JRM Action: AP APPROVED Comment: APPROVED STRUCTURAL SLAB AND STAIRS EAST END OF BLDG 08/20/08 Inspector: JGG Action: AP APPROVED Comment: Footing steel OK. Item: 20 BLDG-Foundation/Steel Approved 09/27/07 Inspector: shahn Action: PI PARTIAL INSPECTION Comment: PARTIAL FOUNDATION ON SOUTH SIDE AS HILITED IN YELLOW FIRST LIFT. 09/28/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: 2nd LIFT OF NWE FOUNDATION WALL SOUTH SIDE AT EXISTING WALL 10/03/07 Inspector: shahn Action: PI PARTIAL INSPECTION REPT131 Run Id: 10483 Continued: Comment: Comment: 2ND LIFT ON SOUTH. REST OF FOUNDATION REBAR OK AS HILITED, AND ((1) PAD. 10/22/07 Inspector: shahn Action: NR NOT REAbY FOR INSPECTION Comment: not ready. STEEL IN REBAR DOES NOT MATCH S205/8 AND S202/6. 10/23/07 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: DETAIL 2/S502 UNCLEAR WHY CROSS SECTION REBAR SHOWN. TOLD GC TO CONTACT ENGINEER FOR CLARIFICATION. APPROVED AS NOTED ON PLANS. 10/26/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: SOUTH RETAINING WALL PROVIDE ENG STAMPED DRAWING OF CHANGE TO WALL. 11/16/07 Inspector: s remmer Action: PA PARTIAL APPROVAL Comment: north portionof foundation 11/21/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: PATIO SLABS 02/26/08 Inspector: SHAHN Action: PA PARTIAL APPROVAL Comment: SPA FOOTER REBAR APPROVED. 02/29/08 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: LAUNDRY ROOM SLAB, FIREPLACE STRUCTURAL SLAB, AND GARAGE SLAG. 03/04/08 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: PARTIAL APPROVED 1ST POUR OF SITE WALL SPA SURROUND 04/28/08 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: STRUCTURAL SLAB ON NORTH SIDE APPR 05/07/08 Inspector: SHAHN Action: PA PARTIAL APPROVAL Comment: STAIR ENTRYWALL AND SPA LINTEL REBAR AS HILITED. 08/22/08 Inspector: NSC Action: AP APPROVED Comment: foundation wall is ok. maintain clearence to form's Item: 21 PLAWILC Foundation Plan Approved 09/08/08 Inspector: Warren Action: AP APPROVED Comment: Reviewed and approved in Bill Gibson's absence Item: 30 BLDG-Framing Approved 09/05/08 Inspector: GCD Action: DN DENIED Comment: 1.ILC REQD 2.FIREPLACE PERMIT SILL IN DENIED STATUS 09/09/08 Inspector: GCD Action: CR CORRECTION REQUIRED Comment: 1. 14" LVL SPECTED AT ROOF FRAMING ABOVE TRANSOM WINDOW. 2.DRAFT STOP MECHANICAL CHASE AT FLOOR LEVELS. 3.VERIFY SPACING OF CLIPS AT SHEAR WALLS. 4.PROVIDE STEEL SPECIAL INSPECTION FOR WELDING. 5.PROVIDE DETAIL 1/S104 6.AT B SHEAR WALL IN LAUNDRY ADD ANCHOR BOLTS TO = 2' ON CENTER. SAME AT SHEAR WALL C IN BATH TO = 1' OC. 7.PROVIDE SHEAR WALL D IN CLOSET OR ALTERNATE. 09/10/08 Inspector: GCD Action: CR CORRECTION REQUIRED Comment: CONTINUATION OF FRAMING FROM 09-09-08 8.IN CRAWLSPACE AT SHEAR WALL B TIGHTEN ANCHOR BOLTS AND ADD ONE AT PLATE SPLICE. 9.DETAIL 13 ON S/203 WAS DELETED PROVIDE ENG APPROVAL 10.PROVIDE REVISED PLANS AND SSK DETAILS. NO MORE INSPECTIONS UNTIL FIREPLACES ARE PERMITTED AND INSPECTED 09/19/08 Inspector: JRM Action: AP APPROVED Comment: FRAMING APPROVED. FIREPLACE PERMIT STILL DENIED DESIGNEER TO MEET WITH INSPECTOR TO DISCUSS ITEMS CORRECTED WELDING REPORT REC'D, Item: 22 PLAN-ILC FRAMING Approved *1 09/08/08 Inspector: Warren Action: AP APPROVED Comment: Reviewed and approved in Bill Gibson's absence Item: 50 BLDG-Insulation Approved 10/27/08 Inspector: JGG Action: AP APPROVED Comment: Insulation OK, see comments in LHN. Item: 60 BLDG-Sheetrock Nail Approved 11/12/08 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: LOWER LEVEL- BEDROOMS 1,2,3 MEDIA ROOM AND LAUNDRY. 11/28/08 Inspector: GCb Action: AP APPROVED Comment: LOWER LEVEL BEDROOMS 4 AND 5. MASTER BEDROOM AND CLOSET AND BATHROOM WITH TUB, (EXCLUDING BATH WITH SHOWER). LAUNDRY AND PANTRY (NOT KITCHEN). UPPER LEVEL OPEN ROOM AND STAIR WELL. AREAS NOT READY MAIN ENTRY AND DINING AND GREAT ROOMS. 12/16/08 Inspector: JGG Action: PA PARTIAL APPROVAL Comment: Kitchen and great room OK. Several sheets missing, due to Corten finish material to be installed later. Drywall screws OK. 12/17/08 Inspector: JGG Action: PA PARTIAL APPROVAL Comment: Kitchen, great room OK, Corten panels to be installed. 01/22/09 Inspector: JGG Action: PA PARTIAL APPROVAL Comment: Ceiling and east wall living room were OK. 02/04/09 Inspector: JRM Action: PA PARTIAL APPROVAL Comment: GARAGE WALLS AND PARTIAL CEILING ONLY (MISSING CEILING GYP NORTH HALF Item: 70 BLDG-Misc. Item: 90 BLDG-Final Item: 532 PW-TEMP. C/O Approved 07/17/09 Inspector: Is Action: CR CORRECTION REQUIRED Comment: Retaining wall exceed 6 ft in height contractor to provide bond for repairs. Parking issues and dumpster removal required before ~'W is signing off on TCO. 07/23/09 Inspector: Is Action: AP APPROVED Comment: REPT131 Run Id: 10483 10-15-2009 Inspection Request Reporting Page 3 4:25 pm Vail, r_O City Ot item: 533 PLAN-TEMP. C/O Approved 07/16/09 Inspector: bgibson Action: CR CORRECTION REQUIRED Comment: retaining walls exceed 6 feet in height. DIA received for driveway and landscaping. 07/20/09 Inspector: bgibson Action: AP APPROVED Comment: DIA received for retaining wall height corrections Item: 530 BLDG-Temp. C/O Approved 07/17/09 Inspector: JRM Action: AP APPROVED Comment: Item: 539 PW-FINAL C/O Approved 09/10/09 Inspector: Is Action: AP APPROVED Comment: Item: 537 PLAN-FINAL C/O Approved 09/09/09 Inspector: bgibson Action: AP APPROVED Comment: Item: 540 BLDG-Final C/O 09/09/09 Inspector: c Action: CR CORRECTION REQUIRED Comment: 1) 20 MINUTE LABELS REQUIRED ON DOORS BETWEEN MECHANICAL ROOM AND ARAGE AND CRAWL SPACE 2 PULL GRADE AWAY FROM SIDING AT REAR OF HOUSE 6" MIN. 3 PUBLIC WORKS FINAL IS REQUIRED REPT131 Run Id: 10483 APPLICA I T AC6PT C LIPL E OR UNSIGNED`ഀ Project C'jഀ Building Permitഀ i' 970-479-2149 (Inspections)ഀ IOWNOF VARL ' TOWN OF VAIL BUILDING PERMIT APPLICATIONഀ Separate Permits are required for electrical, plumbing, mechanical, cഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ CONTRACTOR INFORMATIONഀ r,ഀ rഀ General Contractor: 11 Town of it Reg. Contact Person and Phone #'s:ഀ GEORGE SHAEFFER CONSTRUC ION 1 I Mitch Sturde 970-390-5605ഀ Email address: mitchs sconc . com Fax 970-84507013ഀ Contractor Signature:ഀ CnMPI FTF VAI I IATInNS FnR RI III nimr; PFRMIT /l ahnr & Matprialslഀ BUILDING: .m.000ഀ ELECTRICAL: $ഀ OTHER: $ഀ PLUMBING: $ഀ MECHANICAL: $ഀ TOTAL: $ഀ ForParce/# ConfaclEaa/e CouatvAssessors Office at 970-328-86dO or visit www eaa/e-comwh!comഀ Parcel # 210107113012ഀ Job Name: Dayton Residenceഀ Job Address: 344 BEaver Dam Rdഀ Legal Description Lot: 1 0 Block: 2 Filing: 3rd Subdivision:ഀ Owners Name: John Dayton Addre"s 703 Routh St Dallas TX 7ഀ 2 o1ne:ഀ Architect/Designer: Address:ഀ Phone:ഀ 970-479-2990ഀ Engineer: Solu ioness: PO Box 2494 Avon, CO 8161ഀ Ohon 70-949-71 00ഀ Detailed description of wor :ഀ acs Q rA 12.E V'M N'.wഀ )ഀ Work Class. New Addition ( ) Remodel(--) Repair( ) Demo %M Other(ഀ Work Type: Interior ( ) Exterior ( ) Both 7 X Does an EHU exist at this location: Yes ( ) No (X)ഀ Type of Bldg.: Single-family (X) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )ഀ No. of Existing Dwelling Units in this building: n /a No. of Accommodation Units in this building: n/aഀ No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burnin g (X)ഀ No/T e of Fire laces Proposed: Gas Appliances Gas L s Wood/Pellet Wood Burning NOT ALLOWEDഀ Does a Fire Alarm Exist: Yes( ) No k) Does a ire Sprinkler System Exist: Yes( ) No(ഀ **********Ft*****************************FOR OFFIC USEഀ Type of Construction: FAccepted ate Receivla:ഀ Occupancy Group: By _Aഀ F:\cdev\FORMS\Permits\Building\building_permit 4-21-06. DOCഀ 1 of4dN ; '52007ഀ N OF VAILഀ Iഀ Questions? Call the Building Team at 479-2325ഀ •ഀ WOO Building Permit Submittal Checklistഀ Department of Community Developmentഀ Project Name: _ഀ Project Address:ഀ ✓ This Checklist must be completed before a Building Permit application isഀ accepted.ഀ ❑ All pages of application is completeഀ ❑ Has DRB approval obtained (if required) Provide a copy of approval formഀ ❑ Plan Check Fee required at submittal for projects valued over $100,000.00 (see attached feeഀ schedule)ഀ ❑ Complete site plan submittedഀ ❑ Public Way Permit application included if applicable (refer to Public Works checklist)ഀ ❑ Staging plan included (refer to Public Works checklist) No dumpster,parkina or material storageഀ allowed on roadways and shoulders without written approvalഀ ❑ Asbestos test and results submitted if demolition is occurringഀ ❑ Architect stamp and signature (All Commercial and Multi family)ഀ ❑ Full floor plans including building sections and elevations(3 sets for remodels, 4 sets of plans for SFRഀ and Duplex, 5 sets of plans for Multi-Family and Commercial Buildings)ഀ ❑ Window and door scheduleഀ ❑ Full structural plans, including design criteria (i.e.loads)ഀ ❑ Structural Engineer stamp and signature on structural plans (All Commercial and Multi Family)ഀ ❑ Soils Report must be submitted prior to footing inspectionഀ ❑ Fire resistive assemblies specified and penetrations indicatedഀ ❑ Smoke detectors shown on plansഀ ❑ Types and quantity of fireplaces shownഀ Applicant's Signature: 4-#/ tഀ Date of submittal: .ഀ Received By:ഀ F: \cdev\FORMS\Permits\Building\building-permit. DOC Page 2 of 16 02/09/2005ഀ 0ഀ MWNOF SAIL 'ഀ ASBESTOS TESTING REQUIREMENTSഀ THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTINGഀ ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED.ഀ AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDINGഀ MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVEഀ NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT.ഀ A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ • I have included the asbestos test and report with my building permit applicationഀ 6-/S-0) st jO'c i ry a I ~J ~ ~ Petഀ L30 0162ഀ signatureഀ ORഀ dateഀ • I certify my project will not disturb or remove more than 160 s.f. of building material. The constructionഀ plans submitted with my application clearly indicate this information. (This will be verified during planഀ review, and will delay your project if found to be inaccurate)ഀ applicant signatureഀ ORഀ dateഀ • The building was constructed after October 12, 1988. The date of construction wasഀ original construction dateഀ applicant signature dateഀ F:\cdev\FORMS\Permits\Building\building-permit. DOC Page 4 of 16 02/09/2005ഀ Permit #ഀ Permit Dateഀ 0 REScheck Software Version 3.7.3ഀ 8/" Compliance Certificateഀ Project Title: Dayton Residenceഀ Report Date: 08/03/07ഀ Data filename: C:\DOCUME-1\ADMINI-1\LOCALS--1\Temp\DAYTON-RE-1.RCK.rckഀ Energy Code: 2003 IECCഀ Location: Vail, Coloradoഀ Construction Type: Single Familyഀ Glazing Area Percentage: 23%ഀ Heating Degree Days: 9248ഀ Construction Site:ഀ 344 Beaver Dam Roadഀ Vail, COഀ Owner/Agent:ഀ Millie Aldrichഀ KH Webb Architectsഀ 710 W. Lionshead Circleഀ Vail, CO 81657ഀ 970-477-2990ഀ millie@khwebb.comഀ Designer/Contractor:ഀ Mitch Sturdeഀ George Schaeffer Constructionഀ PO Box 373ഀ Vail, CO 81658ഀ 970-845-5656ഀ mitchs@gsconco.comഀ Ceiling 1: Flat Ceiling or Scissor Truss:ഀ 3767ഀ 28.0ഀ 28.0ഀ 66ഀ Skylight 2: Metal Frame with Thermal Break:Double Pane withഀ 92ഀ 0.350ഀ 32ഀ Low-E:ഀ Wall 1: Wood Frame, 16" o.c.:ഀ 6538ഀ 22.0ഀ 14.0ഀ 181ഀ Window 1: Wood Frame:Double Pane with Low-E:ഀ 875ഀ 0.350ഀ 306ഀ Door 1: Glass:ഀ 632ഀ 0.350ഀ 221ഀ Basement Wall 1: Solid Concrete or Masonry:ഀ 1613ഀ 11.0ഀ 0.0ഀ 111ഀ Floor 1: All-Wood Joist/Truss:Over Unconditioned Space:ഀ 2991ഀ 38.0ഀ 0.0ഀ 78ഀ Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and otherഀ calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements inഀ REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.ഀ Builder/Designer Company Name Dateഀ Dayton Residenceഀ Page 1 of 4ഀ C~(j REScheck Software Version 3.7.3ഀ Inspection Checklistഀ Date: 08/03/07ഀ Ceilings:ഀ ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-28.0 cavity + R-28.0 continuous insulationഀ Comments:ഀ Above-Grade Walls:ഀ ❑ Wall 1: Wood Frame, 16" o.c., R-22.0 cavity + R-14.0 continuous insulationഀ Comments:ഀ Basement Walls:ഀ ❑ Basement Wall 1: Solid Concrete or Masonry, 10.0' ht/8.0' bg/8.0' insul, R-11.0 cavity insulationഀ Comments:ഀ Windows:ഀ ❑ Window 1: Wood Frame:Double Pane with Low-E, U-factor: 0.350ഀ For windows without labeled U-factors, describe features:ഀ #Panes Frame Type Thermal Break? Yes Noഀ Comments:ഀ Skylights:ഀ ❑ Skylight 2: Metal Frame with Thermal Break:Double Pane with Low-E, U-factor: 0.350ഀ #Panes Frame Type Thermal Break? Yes Noഀ Comments:ഀ Doors:ഀ ❑ Door 1: Glass, U-factor: 0.350ഀ Comments:ഀ Floors:ഀ ❑ Floor 1: All-Wood Joist/Tru ss: Over Unconditioned Space, R-38.0 cavity insulationഀ Comments:ഀ Air Leakage:ഀ ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.ഀ ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance fromഀ combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation.ഀ Skylights:ഀ ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19.ഀ Vapor Retarder:ഀ ❑ Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors.ഀ Materials Identification:ഀ ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.ഀ ❑ Materials and equipment must be identified so that compliance can be determined.ഀ ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.ഀ Dayton Residence Page 2 of 4ഀ ❑ Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications.ഀ Duct Insulation:ഀ ❑ Supply ducts in unconditioned attics or outside the building must be insulated to R-11.ഀ ❑ Return ducts in unconditioned attics or outside the building must be insulated to R-6.ഀ ❑ Supply ducts in unconditioned spaces must be insulated to R-11.ഀ ❑ Return ducts in unconditioned spaces (except basements) must be insulated to R-2.ഀ ❑ Where exterior walls are used as plenums, the wall must be insulated to R-11.ഀ ❑ Insulation is not required on return ducts in basements.ഀ Duct Construction:ഀ ❑ Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened.ഀ ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),ഀ mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.ഀ Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500ഀ Pa).ഀ ❑ The HVAC system must provide a means for balancing air and water systems.ഀ Temperature Controls:ഀ ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off theഀ heating and/or cooling input to each zone or floor shall be provided.ഀ Service Water Heating:ഀ ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integralഀ heat trap or is part of a circulating system.ഀ ❑ Insulate circulating hot water pipes to the levels in Table 1.ഀ Circulating Hot Water Systems:ഀ ❑ Insulate circulating hot water pipes to the levels in Table 1.ഀ Swimming Pools:ഀ ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is fromഀ non-depletable sources. Pool pumps require a time clock.ഀ Heating and Cooling Piping Insulation:ഀ ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Tableഀ 2.ഀ Dayton Residence Page 3 of 4ഀ Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipesഀ Insulation Thickness in Inches by Pipe Sizesഀ Non-Circulating Runoutsഀ Circulating Mains anഀ d Runoutsഀ Heated Waterഀ Temperature (°F)ഀ Up to 1"ഀ Up to 1.25'ഀ 1.5" to 2.0"ഀ Over 2"ഀ 170-180ഀ 0.5ഀ 1.0ഀ 1.5ഀ 2.0ഀ 140-169ഀ 0.5ഀ 0.5ഀ 1.0ഀ 1.5ഀ 100-139ഀ 0.5ഀ 0.5ഀ 0.5ഀ 1.0ഀ Table 2: Minimum Insulation Thickness for HVAC Pipesഀ Piping System Typesഀ Fluid Temp.ഀ Rangeff)ഀ Heating Systemsഀ Low Pressure/Temperatureഀ 201-250ഀ Low Temperatureഀ 106-200ഀ Steam Condensate (for feed water)ഀ Anyഀ Cooling Systemsഀ Chilled Water, Refrigerant andഀ 40-55ഀ Brineഀ Below 40ഀ Insulation Thickness in Inches by Pipe Sizesഀ 2" Runouts 1" and Less 1.25' to 2.0" 2.5" to 4"ഀ 1.0ഀ 1.5ഀ 1.5ഀ 2.0ഀ 0.5ഀ 1.0ഀ 1.0ഀ 1.5ഀ 1.0ഀ 1.0ഀ 1.5ഀ 2.0ഀ 0.5ഀ 0.5ഀ 0.75ഀ 1.0ഀ 1.0ഀ 1.0ഀ 1.5ഀ 1.5ഀ NOTES TO FIELD: (Building Department Use Only)ഀ Dayton Residence Page 4 of 4ഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ NEW (SFR,P/S,DUP) PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ OWNER DAYTON, JOHN W. & ARLENE J. 06/27/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ CONTRACTOR GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ Desciption: DEMO AND BUILD A NEW SFRഀ Occupancy Typeഀ Totals...ഀ Factorഀ Number of Dwelling Units: 1ഀ Town of Vail Adjusted Valuation: 3,000,000.00ഀ Permit B07-0192ഀ Project PRJ06-0162ഀ Statusഀ ISSUEDഀ Applied..:ഀ 06/27/2007ഀ Issued .ഀ 08/06/2007ഀ Expires.....:ഀ 02/02/2008ഀ Phone: 845-5656ഀ Phone: 845-5656ഀ Sq Feet Valuationഀ 8,200 $3,000,000.00*ഀ Revision Valuation: $20,000.00ഀ :s*»tr*ttrv****t«s*****s*+*******+rrs**s****a**s**+**++** FEE SUMMARY ****r***+x*******+a*►******«■r**+*********+*r****ഀ Building > $12, 981.75 Restuarant Plan Review-->ഀ $0.00 Total Calculated Fees----->ഀ $22, 817.89ഀ Plan Check $8,436.14 Recreation Fee------------ >ഀ $1,230.00 Additional Fees >ഀ $0.00ഀ Investigation-> $0.00 TOTAL FEES >ഀ $22,817.89 Total Permit Fee----------->ഀ $22, 817.89ഀ Will Call-----> $3.00ഀ Payments >ഀ $22, 817.89ഀ BALANCE DUE--------- >ഀ $0.00ഀ ***+~:~+*+*s*«~«***«r***~s*~:*s*e~**~**~**~**~**►****.****+*+***r***r►**+sഀ **~r*~«a*~**~~«*a~rs*****~**+e+**r*►r*~:.*::++**~:*~~**~a*~*~**►*~~*+***ഀ Approvals:ഀ Item: 05100 BUILDING DEPARTMENTഀ 08/01/2007 cgunion Action:ഀ CONDഀ see conditionsഀ 08/31/2007 cgunion Action:ഀ APഀ approved revised structuralഀ and arch. planഀ re-issued field setഀ Item: 05400 PLANNING DEPARTMENTഀ 07/21/2007 bgibson Action:ഀ APഀ office set routed to G-1ഀ Item: 05600 FIRE DEPARTMENTഀ 07/03/2007 JJR Action:ഀ APഀ See conditions.ഀ Perimeter exceeds 300'.ഀ ഀ CONDITIONS OF APPROVALഀ Permit B07-0192 as of 09-05-2007 Status: ISSUEDഀ ഀ Permit Type: NEW (SFR,P/S,DUP) PERMITഀ Applicant: GEORGE SHAEFFER CONSTRUCTIONഀ Job Address: 344 BEAVER DAM RD VAILഀ Applied: 06/27/2007ഀ Issued: 08/06/2007ഀ Location: 344 BEAVER DAM RDഀ Parcel No: 210107113012ഀ ഀ CONDITIONSഀ ഀ Cond: 33ഀ (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALLഀ BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ Cond: CON0009117ഀ Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFESഀ standards.ഀ Cond: CON0009119ഀ Monitored fire alarm system required and shall comply with NFPA 72(2002) andഀ VFES standards.ഀ Cond: 18ഀ (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC ORഀ SECTION 1009 OF THE 2003 IBC.ഀ Cond: 19ഀ (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTIONഀ 1012 OF THE 2003 IBC.ഀ Cond: 34ഀ (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTINGഀ INSPECTION WILL BE CALLED FOR.ഀ Cond: 39ഀ (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION 8310ഀ OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.ഀ Cond: CON0009189ഀ Provide stamped PE drawings of retaining walls with factor of safty, designഀ perameters and assumptions.ഀ Entry: 08/02/2007 By: gc Action: APഀ Landscape features prevent fire department access.ഀ Fire sprinkler system and fire alarm system required.ഀ Item: 05500 PUBLIC WORKSഀ 08/02/2007 gc Action: COND see conditionsഀ Item: 05550 ENGINEERING CIVILSഀ See the Conditions section of this Document for any conditions that may apply to this permit.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV/%/V /EPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AMഀ 4 PM.ഀ SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNERഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R070001756 Amount: $285.45 09/05/200710:49 AMഀ Payment Method: Check Init: JSഀ Notation: 90201/GEORGEഀ SHAEFFER CONST. COഀ ഀ Permit No: B07-0192 Type: NEW (SFR,P/S,DUP) PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $22,817.89ഀ This Payment: $285.45 Total ALL Pmts: $22,817.89ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ BP 00100003111100 BUILDING PERMIT FEES 73.00ഀ PF 00100003112300 PLAN CHECK FEES 212.45ഀ ഀ , C. ~ - j ~.s t\3 " Iഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNEDb Gഀ Building Permit Q d-2- `ഀ 970-479-2'149 (Inspections)ഀ W REVISION TO TOWN OF VAIL BUILDING PERMITഀ Separate Permits are req strfsa~,. mechanical, etc.!ഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ ***All Revision submittals must include the ll~ild Set of approved ns. No further inspectionsഀ will be preformed unti revisions are apprb', d.ഀ General Contractor: Town of V ' hone #'s:ഀ e /yI S t oഀ ATTEN N: JOE, JR, CHARLIE, GREG, CHRISഀ Contractor Signature: W ,lഀ rnneDI GTG DP%IIQInnlc Fuel I IeTI(VC FnR R1 m nimr; PERMIT (Laher & Materials)ഀ REVISED AMOUNT: $ z0 p0? 0ഀ ELECTRICAL: $ 1ഀ 1 OTHER: $ഀ 1 PLUMBING: $ 1ഀ 1 MECHANICAL: $ഀ REVISED TOTAL: $ഀ C-- 0- 1 * C-1f`^nnffii d ccnccnre nffl/-n mf 07n_29R_RRd1) nr vicif 1arUrw Pari1P-rnunty-rnmഀ Parcel #ഀ C7ഀ [Job Name: cഀ Job Address: Y &ggye -ഀ Legal Descriptionഀ Lot: pഀ Block:ഀ Filing:ഀ S,d Jഀ 1 Subdivision:ഀ Owners Name. Address:ഀ `ഀ 4ഀ Phone.ഀ Architect/Desig r: ! Address:ഀ Pഀ hon -Zഀ 0 A re sMഀ o .yy -1ഀ Pone: 6ഀ 1 920ഀ REASON FOR REVISIONS:ഀ r-`G Aഀ Work Class: New (-I- Addition ( ) Remodel ( )ഀ Repair ( ) Demo ( ) Other ( )ഀ Work Type: Interior ( ) Exterior ( ) Both( )ഀ )ഀ Does an EHU exist at this location: Yes ( ) No(ഀ Type of Bldg.: Single-family( ) Two-family( ) Multi-family(ഀ ) Commercial( ) Restaurant( ) Other ( )ഀ No. of Existing Dwelling Units in this building:ഀ [No. of Accommodation Units in this building:ഀ NorT e of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burningഀ No/Type of Fireplaces Proposed: Gas Appliances Gas Los Wood/Pellet Wood Burning NOT ALLOWEDഀ Does a Fire Alarm Exist: Yes( ) No( )ഀ Does a Fire Sprinkler System Exist: Yes( ) No( )ഀ *****FOR OFFICE USE ONLYഀ Date Received: JPermit Fee 10 : Plan Ck Fee 80ഀ Accepted By: Permit Fee (11): Plan Gk Fee ,(81):ഀ Outsourced Terms:ഀ F:\cdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 4/18/2007ഀ yഀ Town of Vailഀ Bill Gibson- Town Plannerഀ Building Departmentഀ Fire Departmentഀ 15 South Frontage Roadഀ Vail, Colorado 81657ഀ Be: Daps Besidesaeഀ 344 Beaver Dam Madഀ Vail, COഀ B074192ഀ Dear Bill -ഀ August 17, 2007ഀ Please review the included four sets of drawings that address permit conditions of approval. I included a full set of structural drawings due to the factഀ that we changed from an EPDM roof to a gravel ballast roof, there were slight modifications with the framing and footing design. We also had someഀ revisions due to coordination between architectural and structural. On the site plan we reduced the size of the driveway and required snow storage.ഀ Building Department Comments:ഀ 1. Add stairway handrail off garage - See revision A101ഀ 2. Any type of ignition source (outlets, relay, etc) must be 18" above garage floor. See revision A100ഀ 3. Masonry fireplace construction. See revision A102, A302, S202ഀ 4. Chimney cap / Boiler flue termination. See revision A104, A200, A300-303ഀ Fire Department requirements for no sprinkler system (see attached email):ഀ 5. Heated path on east side of house. See revision A001ഀ 6. Gravel path on west side and south side of house. See revision A001ഀ 7. Ladder at each retaining wall on west side of house. See revision A001ഀ Please call if you have any questions.ഀ Thank you,ഀ 161j. 1ഀ Millie Aldrich, AIA Assoc.ഀ k.h. webb architects pc.ഀ a~ഀ 3ഀ beഀ 4Si >GOTH rb`6TAGE S „',T STF VAIL :OI,PADO 81457ഀ 970.477.2990 9iC l 6;it www.thwebb.comഀ Kyle,ഀ That works.ഀ Thank you,ഀ Mike McGeeഀ Fire Marshalഀ "Kyle Webb" <kyle@khwebb.com> 07/25/07 12:51 PMഀ Mike,ഀ Per our discussion last Thursday....ഀ We have added ladders and stepping stone path around the West side ofഀ the house.ഀ Please confirm this is acceptable.ഀ Thanks!ഀ Kyleഀ k h w e b bഀ a r c h i t e c t s p cഀ 710 west lionshead circleഀ suite aഀ vail . colorado 81657ഀ 970.477.2990 (p) www.khwebb.com (w)ഀ Page 1 of 2ഀ https://vpn.khwebb.com/exchange/millie/Inbox/Dayton/Re: %20Dayton%2OResidence-16.... 8/17/2007ഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ NEW (SFR,P/S,DUP) PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ 1 jub G - U I Co '1-,ഀ OWNER DAYTON, JOHN W. & ARLENE J. 06/27/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ CONTRACTOR GEORGE SHAEFFER CONSTRUCTION06/27/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ Desciption: DEMO AND BUILD A NEW SFRഀ Occupancy Typeഀ Totals...ഀ Factorഀ Number of Dwelling Units: 1ഀ Town of Vail Adjusted Valuation: 3,000,000.00ഀ Permit B07-0192. 'p 64.. v zഀ Project PRJ06-0162ഀ Statusഀ ISSUEDഀ Applied..:ഀ 06/27/2007ഀ Issued .ഀ 08/06/2007ഀ Expires.....:ഀ 02/02/2008ഀ Phone: 845-5656ഀ Phone: 845-5656ഀ Sq Feet Valuationഀ 8,200 $3,000,000.00*ഀ Revision Valuation: $20,000.00ഀ r+*►****+*«*r*ax*a*«*«+*+*»«:********s*******r*■****r■ FEE SUMMARY rr**st*******►*+****r+++r■r***+**r+*+*+***+*w«:**srrഀ Building > $12, 981.75ഀ Restuarant Plan Review-->ഀ $0.00 Total Calculated Fees-----> $24,137.89ഀ Plan Check $8, 438, 14ഀ Recreation Fee------------ >ഀ $1,230.00 Additional Fees > $0.00ഀ Investigation-> $ 0 . 00ഀ TOTAL FEES >ഀ $24,137.89 Total Permit Fee-----------> $24, 137. 89ഀ Will Call-----> $3 . 0 0ഀ Payments > $24, 137 . 89ഀ BALANCE DUE--------- > $0.00ഀ r~*r+*~~*r+**■~**+r~►*a*ax*****+*~*~***+*r***r***s*r*************~*******~*►********r****~********+*~*****~~********+************~*s***+*:**sr***ഀ Approvals:ഀ Item: 05100 BUILDING DEPAഀ RTMENTഀ 08/01/2007 cgunionഀ Action:ഀ CONDഀ see conditionsഀ 08/31/2007 cgunionഀ Action:ഀ APഀ approved revised structural and arch. planഀ re-issued field setഀ 01/24/2008 cgunionഀ Action:ഀ CONDഀ SEE CONDITIONSഀ Item: 05400 PLANNING DEPAഀ RTMENTഀ 07/21/2007 bgibsonഀ Action:ഀ APഀ office set routed to G-1ഀ 09/14/2007 bgibsonഀ Action:ഀ PAഀ revisionsഀ 01/11/2008 bgibsonഀ Action:ഀ PAഀ revisions approved by planning, plans rout(ഀ Gunionഀ Item: 05600 FIRE DEPARTMENTഀ 07/03/2007 JJR Action: AP See conditions.ഀ Perimeter exceeds 3001.ഀ Landscape features prevent fire department access.ഀ Fire sprinkler system and fire alarm system required.ഀ 01/25/2008 mcgee Action: NO Revisions do not meet the minimum requirem(ഀ fire dept access.ഀ Fire sprinkler system is required.ഀ Item: 05500 PUBLIC WORKSഀ 08/02/2007 gc Action: COND see conditionsഀ 01/25/2008 csalli Action: COND approved with the condition that a catch b<ഀ required to be installed just east of the driveway. The existing 15" and 1811cmps :ഀ connected to the catch basin as well as 15 ltt of new 18" cmp to capture the roadsഀ the east. Contractor notified of condition (Mitch w/ George Schatter) via phone ccഀ 1/15/08.ഀ Item: 05550 ENGINEERING CIVILSഀ ~+~**+*~.*rt**~r~*~~«**r*~:*r+~#*~*~*+►***,r*r*+r**~r~+r*r**s**~*+*rwrt»r*******~**rr*rr~*r+tr~t*++**+:r**+*~***a*****~~~►*+~r*~***+*~+*r***►~rr~*ഀ See the Conditions section of this Document for any conditions that may apply to this permit.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other ordinances of the 7`ovn applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN~C)jl B~ ~E~P}IONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AMഀ 4 PM. AA// ~~~1ഀ SIGNATURE OP,, J NER OR CONTRAC"POR FOR HIMSELF AND OWNERഀ ഀ CONDITIONS OF APPROVALഀ Permit B07-0192 as of 01-30-2008 Status: ISSUEDഀ ഀ Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 06/27/2007ഀ Applicant: GEORGE SHAEFFER CONSTRUCTION Issued: 08/06/2007ഀ Job Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Parcel No: 210107113012ഀ ഀ CONDITIONSഀ ഀ Cond: CON0009743ഀ approved with the condition that a catch basin is required to be installed justഀ east of the driveway. The existing 15" and 18"cmps shall be connected to theഀ catch basin as well as 15 lft of new 18" cmp to capture the roadway ditch toഀ the east.ഀ Cond: 33ഀ (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALLഀ BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION.ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ Cond: CON0009117ഀ Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFESഀ standards.ഀ Cond: CON0009119ഀ Monitored fire alarm system required and shall comply with NFPA 72(2002) andഀ VFES standards.ഀ Cond: 18ഀ (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC ORഀ SECTION 1009 OF THE 2003 IBC.ഀ Cond: 19ഀ (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTIONഀ 1012 OF THE 2003 IBC.ഀ Cond: 34ഀ (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTINGഀ INSPECTION WILL BE CALLED FOR.ഀ Cond: 39ഀ (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310ഀ OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC.ഀ Cond: CON0009189ഀ Provide stamped PE drawings of retaining walls with factor of salty, designഀ perameters and assumptions.ഀ Entry: 08/02/2007 By: gc Action: APഀ Cond: CON0009740ഀ GUARDS REQUIRED AT PATIO AREA AT NORTH AND EAST ELEVATIONS PER NOTES ON PLANSഀ WHERE PATIO OR DECK IS GREATER THAN 30" ABOVE GRADE. GRADE IS MEASURED TOഀ BOTTOM OF PROPOSED POND.ഀ Cond: CON0009741ഀ PLANS STAMPED BY A COLORADO LICENSED STRUCTURAL ENGINER REQUIRED FOR SKYLIGHTഀ ROOFS.PLANS TO BE SUBMITTED AT FRAMING INSPECTION. 100 PSF SNOW LOAD REQUIRED.ഀ Cond: CON0009742ഀ NO COMBUSTIBLE MATERIALS ALLOWED UNDER MASONRY FIREPLACE HEARTH. SEE NOTES ONഀ PLANS.ഀ ഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R080000118 Amount: $1,320.00 01/30/200801:42 PMഀ Payment Method: Check Init: JSഀ Notation: 91923/GEORGEഀ SHAEFFER CONSTഀ ഀ Permit No:ഀ ഀ B07-0192 Type: NEWഀ ഀ (SFR,P/S,DUP) PERMITഀ Parcel No:ഀ 2101-071-1301-2ഀ Site Address:ഀ 344 BEAVER DAM RD VAILഀ Location:ഀ 344 BEAVER DAM RDഀ Total Fees:ഀ $24,137.89ഀ This Payment:ഀ $1,320.00ഀ Total ALL Pmts:ഀ $24,137.89ഀ Balance:ഀ $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Codeഀ Descriptionഀ Current Pmtsഀ ഀ PF 00100003112300ഀ ഀ PLAN CHECK FEESഀ ഀ ഀ 1,320.00ഀ 2ഀ APPLICATIO I likaAm NCOM OR UNSIGN Dഀ Building Permitഀ AL D DEC 19 2007 970-419.2149`(Inspections)ഀ N VMI REVI N -TO TOWN OF IL BUILDING PERMITഀ Separate errrt e(Wff el rical, plumbing, mechanical, etc.!ഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ ***All Revision submittals must include the Field Set of approved plans. No further inspectionsഀ will be performed until the revisions are approved.ഀ CONTRACTOR INFORMATIONഀ General Contractor: Town of Vail Reg. No.: Contact and Phone #'s:ഀ ATTE N: JOE, JR, CHARLIE, GREG, CHRISഀ Contractor Signature:ഀ r_f)MP1 FTF RFVIS1nNS FVAI I IATION4 FOR R1 III DlNr~ PFRMIT (Labor & Materialslഀ REVISED AMOUNT: $ഀ ELECTRICAL: $ Oഀ OTHER: $ Oഀ PLUMBING: $ഀ clt7ഀ MECHANICAL: $ Gഀ REVISED TOTAL: $ഀ Fnr 0nrrn1f! Cnnf~rf Fmnln rnnnf►i Accpccnrc Offir_p of 97n_39R_RRan nr visit in vlw -nrrla-rnuntv_cnmഀ Parcelഀ Job Name:ഀ Job Address: ~Y'K P fഀ Legal Descriptionഀ Lot: Qഀ Block:ഀ [Filing- D 1ഀ Subdivision: V4 1ഀ Owners Name: Address: oഀ ` 7 _ Zഀ hone:ഀ Arc itec Design r: Addre Jഀ / .ഀ ! O v 1,5ഀ 14ഀ Phone: , Z 5 y Oഀ ineee ( Addressഀ vov1 lbഀ _L0ഀ Phone: c _ഀ -7 2ഀ REASON FOR REVISIONS:ഀ e vet Cഀ C..) eഀ [Work Class: New( ) Addition( ) Remodel(ഀ ) Repair ( ) Demo ( ) Other ( )ഀ Work Type: Interior ( ) Exterior ( ) Both( )ഀ )ഀ 11 Does an EHU exist at this location: Yes( ) No(ഀ Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other ( )ഀ No. of Existing Dwelling Units in this building:ഀ No. of Accommodation Units in this building:ഀ No/Type of Fireplaces Existin : Gas Appliancesഀ Gas Los Wood/Pellet Wood Burningഀ No/Type of Fireplaces Proposed: Gas Appliancesഀ Gas Los Wood/Pellet Wood Burning NOT ALLOWEDഀ Does a Fire Alarm Exist: Yes( ) No ( )ഀ Does a Fire Sprinkler System Exist: Yes( ) No( )ഀ *************************************************FOR OFFICE USE ONLY**********************************************ഀ Date Received:ഀ Permit Fee (10):ഀ Plan Ck Fee (80):ഀ Accepted By:ഀ Permit Fee (11):ഀ Plan Ck Fee (81ഀ Outsourced Terms:ഀ F:\cdev\FORMS\Permits\Building\buiIding_revision_4-18-2007.doc Page 1 of 1 4/18/2007ഀ Iഀ Town of Vailഀ Bill Gibson- Town Plannerഀ Design Review Boardഀ Chris Gunion - Building Departmentഀ 75 South Frontage Roadഀ Vail, Colorado 81657ഀ Re: Dayton Residenceഀ 344 Beaver Dam Roadഀ Vail, COഀ B07-0 192ഀ Dear Bill / Chris-ഀ December 6, 2007ഀ I have included seven sets of the Dayton residence; three sets for DRB and four stamped sets for the Building Department. Please review the drawingsഀ that address changes to approved plans. There have been several small changes indicated with revision clouds, but since many sheets have been revisedഀ i included the full set so everyone has the same information.ഀ DBR changes:ഀ 1. Revised exterior windows - See A200, A201 (rev. clouds)ഀ 2. Revised entry roof material - See A104, A200ഀ 3. Revised drive material and pattern - 1.1.3ഀ 4. Added 4 spruce trees on rear of property - See 1-3.1 (rev. clouds)ഀ S. Revised tree / shrub layout to allow for bark mulch path for fire access - See 1-3.1ഀ 6. South west retaining wall moved closer to the house to help grading - See A001, A101 (rev. clouds)ഀ Building Department changes:ഀ 7. Some exterior walls changed from 2x6 to 2x8 due to change in window supplier - See rev. cloudsഀ 8. Eliminated steel in the entry hall walls due to change stair design - See Structural rev. cloudsഀ 9. Changes in framing to support specific art piecesഀ 10. Changes in roof framing to allowing room for recessed cansഀ 11. hanger changesഀ 12. Changes due to relocating windowsഀ Please call if you have any questions.ഀ Thank you,ഀ a~ Millie Aldrich, AIA Assoc.ഀ U. webb architects pc.ഀ 941 1OUIH ?QHIA1- E R.QF:D ,ESI X16 VAit A1,OrA11] 91651ഀ 970.471.2990 971) 111.1964(1 www.khwebb_con?ഀ 9ഀ SOIL AND FOUNDATION INVESTIGATIONഀ FOR THEഀ PROPOSED DAYTON RECONSTRUCTIONഀ LOT 10, BLOCK 2, VAIL VILLAGE, 3" FILINGഀ 344 BEAVER DAM ROADഀ TOWN OF VAILഀ EAGLE COUNTY, COLORADOഀ PROJECT NO. 05153ഀ MAY 22, 2007ഀ PREPARED FOR:ഀ MR. KYLE WEBBഀ KH WEBB ARCHITECTS, PCഀ 710 WEST LIONSHEAD CIRCLE, UNIT Aഀ VAIL, CO 81657ഀ TABLE OF CONTENTSഀ EXECUTIVE SUMMARY 2ഀ SCOPE OF STUDY 2ഀ SITE DESCRIPTION 3ഀ PROPOSED CONSTRUCTION 3ഀ FIELD INVESTIGATION 3ഀ SUBSURFACE SOIL AND GROUNDWATER CONDITION 4ഀ FOUNDATION RECOMMENDATIONS 4ഀ SLAB CONSTRUCTION 6ഀ RETAINING WALLS 7ഀ UNDERDRAIN SYSTEM 7ഀ SITE GRADING AND DRAINAGE 8ഀ LAWN IRRIGATION 9ഀ LIMITATION 9ഀ FIGURESഀ LOCATION SKETCH .........................................DRAWING NO. Iഀ SUBSURFACE EXPLORATION LOGS ..................FIGURE NO'S I & 2ഀ SWELL/CONSOLIDATION RESULTS ...........................FIGURE NO'S 3 - 4ഀ EXECUTIVE SUMMARYഀ 1. Ground water dewatering will be necessary for the construction ofഀ the proposed remodel/reconstruction.ഀ 2. The proposed remodel/reconstruction should be supported withഀ conventional type spread footings, designed for an allowable soilഀ bearing pressure of 3500 psf and a minimum dead load ofഀ 1000ps£ They should construct the footings on the undisturbed,ഀ bedrock, below all fill and topsoil. See Foundationഀ Recommendations for other alternatives.ഀ SCOPE OF STUDYഀ This report presents the results of a follow up subsurface Soil and Foundationഀ Investigation for the proposed Dayton Remodel, Lot 10, Block 2, Vail Village 3`d Filing,ഀ Town of Vail, Eagle County, Colorado. The purpose of the subsurface soil and foundationഀ investigation was to test the soil closer to the residence, to determine the engineeringഀ characteristics of the foundation soil and to provide recommendations for the foundationഀ design, grading, and drainage. Also, it was required to test the soil as close as possible toഀ the existing pond for foundation recommendations for the proposed hot tub that will beഀ located near the northeast corner of the new residence.ഀ LKP Engineering, Inc.ഀ SITE DESCRIPTIONഀ Lot 10 is a 0.4724-acre lot, at 344 Beaver Dam Road, in the Town of Vail, Eagleഀ County, Colorado. The topography is moderate to steep. Drainage is to the north andഀ northwest. Vegetation on the lot consisted of pines, grass and service berries. To the northഀ of the existing residence there is a pond, wet areas, a small stream, and thick, wetlandഀ type vegetation. The lot has an existing residence and a gravel driveway. At the time ofഀ drilling, most of the residence had been demolished. Most of the foundation and some ofഀ the framing remained, but will be demolished at a later date. The pond was emptied andഀ there was a sump pump continuously pumping ground water leaching into the pond areaഀ from the uphill side. There was also, a lot of construction debris on the site.ഀ PROPOSED CONSTRUCTIONഀ We understand that the proposed new residence will be a full reconstruction of theഀ existing residence. Except for the back, concrete foundation wall, that will be used forഀ shoring, the entire structure will be demolished. The new building will be a wood frameഀ construction on a concrete foundation. Loads are anticipated to be light, typical ofഀ residential construction.ഀ If the finalized plans differ significantly from the above understanding, theyഀ should notify us to reevaluate the recommendations of this report.ഀ FIELD INVESTIGATIONഀ The field investigation conducted on May 11, 2007, consisted of boring, loggingഀ and sampling two test borings. The test boring locations are shown on Drawing No. 1.ഀ Drilling of the test borings was done with a 4-inch diameter, continuous flight, a powerഀ LKP Engineering, Inc.ഀ 4ഀ auger, on a truck mounted drill rig. We show the soil profiles of the test borings on theഀ Subsurface Exploration Logs, Figure No's one through three. Soil samples for laboratoryഀ soil analysis and observation were taken at selected intervals by advancing Standard Splitഀ Spoon and California Samplers with a 140-pound hammer, falling 30 inches.ഀ SUBSURFACE SOIL AND GROUNDWATER CONDITIONഀ The soil profiles encountered in the test borings were fairly uniform. Boring No. 1ഀ had less than one foot of topsoil over four feet of brown, silty, clayey sand over 9.5 feet ofഀ claystone bedrock. Boring No. 2 (next to the pond) had 6.5 feet of fill (consisting ofഀ topsoil, clay and gravel) over 6.5 feet of claystone and sandstone bedrock. Ground waterഀ was encountered at the time of drilling in both borings. Ground water measurements wereഀ taken as shown on the table below:ഀ BORING/DATEഀ AT DRILLINGഀ END OF DRILLINGഀ 5/18/07ഀ 5/22/07ഀ B-1ഀ 11.5'ഀ 11.5'ഀ 10.5'ഀ 10.7ഀ B-2ഀ 12.5'ഀ 3.5'ഀ 2'ഀ 2.3'ഀ We sampled the soil in the test borings at random intervals. The soil samples wereഀ brought to our laboratory for observation and analysis. They were tested for natural dryഀ density, natural moisture content and swell/consolidation, as shown on theഀ Swell/Consolidation Test Results, Figure No.'s 3 and 4.ഀ FOUNDATION RECOMMENDATIONSഀ Due to the high ground water elevation extreme care should be taken during theഀ LKP Engineering, Inc.ഀ 5ഀ design and the construction stages on this lot. Ground water dewatering will be part of theഀ design.ഀ One alternative for the proposed remodel is to be supported with conventional typeഀ spread footings, or pads and beams, designed for a maximum allowable soil bearingഀ pressure of 3500 psf and a minimum dead load of 1000psf. The footings should be placedഀ on the undisturbed, claystone bedrock. For this alternative, ground water dewatering andഀ improvement of the foundation subgrade might be necessary. The ground water elevationഀ can vary, and it is possible it will rise as high as the proposed foundation. A minimum ofഀ two feet of separation should be maintained between the ground water and the bottom of aഀ concrete slab.ഀ Another alternative for the proposed remodel is to be supported with strait shaftഀ piers, designed for an allowable end bearing pressure of 10,000 psf and skin friction ofഀ 1000 psf. The piers should be imbedded for a minimum of twice the pier diameter intoഀ firm, bedrock. They should support the footings for the entire foundation with piers. Dueഀ to the high ground water level, the piers would have to be incased with permanent casing.ഀ A pier diameter of 18 inches is recommended. Each pier hole must be inspected by theഀ undersigned engineer, prior to concrete placement.ഀ The high ground water elevation can impact the foundation bearing soils. Groundഀ water dewatering will be necessary. We recommend an underdrain behind every step ofഀ the foundation.ഀ We also recommend two feet of gravel under the slab on grade areas. The gravelഀ should be connected with the perimeter drain. More detailed recommendations for theഀ underdrain system can be provided once the foundation and grading plans are completed.ഀ We recommend minimum width of 16 inches for the continuous footings and 2ഀ feet for the isolated footing pads. Continuous foundation walls should be reinforced topഀ and bottom to span an unsupported length of at least 10 feet.ഀ We recommend a minimum of 48 inches of backfill cover for frost protection ofഀ LKP Engineering, Inc.ഀ 6ഀ the footing subsoils. The foundation excavation should be observed by the undersignedഀ engineer to verify that the soil conditions encountered during construction are asഀ anticipated in this report. The foundation excavation should be free from excavationഀ spoils, frost, organics and standing water. Any overexcavation within the proposedഀ foundation, should be backfilled, with minus 3/4-inch to minus 3-inches of clean, crushedഀ rock. If the thickness of the structural fill exceeds three feet, it should be reinforced withഀ layers Tensar 1200X Geogrid.ഀ SLAB CONSTRUCTIONഀ The natural, on-site soils, have a moderate swelling potential, and are not suitableഀ to support lightly loaded slab-on-grade construction. Also, the high ground water levelഀ should be considered, when determining the slab on grade elevation. Where possible aഀ structural floor over a crawl space should be constructed. The crawl spaces should beഀ ventilated according to the building code requirements.ഀ Based on the findings from the soil and foundation investigation, a structural fillഀ will be needed to provide a minimum separation of two feet between the high groundഀ water table and the bottom of the proposed slab on grade. An underdrain system will alsoഀ be necessary for the slab on grade areas. They should backfill overexcavated soft spotsഀ and other underslab fill with minus 3/4-inch to minus 3-inches of clean, crushed rock. Theഀ concrete slab should be constructed over a 24-inch layer of clean gravel.ഀ They should reinforce the concrete slab-on-grade and score control jointsഀ according to the American Concrete Institute requirements and per the recommendationsഀ of the designer to reduce damage due to shrinkage. The concrete slab should be separatedഀ from the foundation walls and columns with expansion joints to allow for independentഀ movement without causing damage.ഀ LKP Engineering, Inc.ഀ 7ഀ RETAINING WALLSഀ They should design foundation walls retaining earth and retaining structures thatഀ are laterally supported to resist an equivalent fluid density of 60 pcf for an "at-rest"ഀ condition. Laterally unrestrained structures retaining the on-site earth should be designedഀ to resist an equivalent fluid density of 40 pcf for the "active" case.ഀ Passive earth pressure of 340 psf can be used for the lateral pressure against theഀ sides of the footings. Resistance to sliding at the bottom of the footings can be calculatedഀ based on a coefficient of friction of 0.45. Undisturbed soil or a structural fill compacted toഀ 100 percent of the maximum dry density and within 2 percent of the optimum moistureഀ content shall be used to resist lateral loads at the sides of the footings.ഀ The above design recommendations assume drained backfill conditions and aഀ horizontal backfill surface. Surcharge loading due to adjacent structures, weight ofഀ temporary stored construction materials and equipment, inclined backfill and hydrostaticഀ pressure due to undrained backfill should be incorporated in the design. They should tryഀ to prevent the buildup of hydrostatic pressure behind the retaining wall.ഀ UNDERDRAIN SYSTEMഀ Due to the high ground water table an underdrain system will be required for thisഀ site. A temporary interceptor trench or trenches stepping into the site will be needed toഀ lower the ground water at least temporarily in order to construct the foundation. Some ofഀ these can become permanent drains. Additional lateral underdrains will be needed toഀ divert the ground water flow into collector drains that will in turn direct the water toഀ daylight by gravity if at all possible, depending on the depth of the foundation. The lateralഀ drain pipes should consist of a 4-inch diameter perforated pipe sloping to the collectorഀ drain. The collector drains will be 6-inch-diameter, perforated pipe, sloping to daylight.ഀ LKP Engineering, Inc.ഀ 8ഀ The drains should slope at 1/4 inch per foot minimum. The drain pipe should be laid overഀ filter fabric and covered with a minimum of 24 inches of -3/4 inch free-draining granularഀ material or to above the seepage line (whichever is more restrictive). Geotextile (Mirafiഀ 140N or equivalent) should be used to cover the free-draining gravel to prevent siltationഀ and clogging of the drain. The backfill above the drain should be granular material toഀ within 2 feet of the ground surface to prevent a buildup of hydrostatic pressure. The topഀ one foot of the backfill material should consist of a relatively impervious fill. The backfillഀ should be sloping away from the building. Detailed recommendations for the underdrainഀ system will be coordinated, once the plans are more complete, and at the time ofഀ construction.ഀ SITE GRADING AND DRAINAGEഀ The following recommendations are general. The site surrounding the buildingഀ structure should slope away from the building in all directions. A minimum of 12 inchesഀ in the first 10 feet is recommended in unpaved areas, and three inches in the first 10 feetഀ in paved areas. The top of the granular foundation backfill should be covered with aഀ minimum of 1 foot of relatively impervious fill to reduce the potential of surface waterഀ infiltrating the foundation subsoils.ഀ Surface water naturally draining toward the proposed building site or permanentഀ cuts, should be diverted around and away from it by means of drainage swales or otherഀ approved methods. The roof drains and downspouts should extend and discharge beyondഀ the limits of the backfill. Exterior backfill should be compacted at or near the optimumഀ moisture content to at least 95% of the maximum standard Proctor density underഀ pavement, sidewalk and patio areas and to at least 90% of the maximum standard Proctorഀ density under landscaped areas. Mechanical methods of compaction should be used. Doഀ not puddle the foundation excavation.ഀ LKP Engineering, Inc.ഀ 9ഀ LAWN IRRIGATIONഀ It is not recommended to introduce excess water to the foundation soils byഀ installing sprinkler systems next to the building. The installation of the sprinkler headsഀ should insure that the spray from the heads will not fall within 10 feet of foundation walls,ഀ porches or patio slabs. Lawn irrigation must be controlled.ഀ LIMITATIONഀ This report has been prepared according to locally accepted Professionalഀ Geotechnical Engineering standards for similar methods of testing and soil conditions atഀ this time. There is no other warranty either expressed or implied.ഀ The findings and recommendations of this report are based on field exploration,ഀ laboratory testing of samples obtained at the specific locations shown on the Locationഀ Sketch, Drawing No.I and on assumptions stated in the report. Soil conditions at otherഀ locations may vary, which may not become evident until the foundation excavation isഀ completed. If soil or water conditions seem different from those described in this reportഀ we should be contacted immediately to reevaluate the recommendations of this report.ഀ This report has been prepared for the exclusive use Mr. Kyle Webb, KH Webbഀ Architects, PC, for the specific application to the proposed Dayton Remodel, Lot 10,ഀ Block 2, Vail Village, 3rd Filing, 344 Beaver Dam Road, Town of Vail, Eagle County,ഀ Colorado.ഀ Sincerely,ഀ LKP ENGINEERING, INC.ഀ Luiza Petrovska, PEഀ Presidentഀ J:\WP 12-LKP\2005\05153sw.rpt.wpdഀ LKP Engineering, Inc.ഀ BEqWR DAM ROഀ ADഀ w~ഀ Oഀ OLD a-tഀ LOT 9ഀ PARTIALLYഀ DEMOLISHED ~ ,ഀ DUSTING VAX VA.L"ഀ FM MWഀ rഀ BUILDING B-2ഀ LOT 10ഀ 0.4724-ACRESഀ 34 "ഀ B-t faഀ LOT tഀ NOTE WE PLAN FRONDED BY OTHERSഀ LOCATION SSETCSഀ CFMVGWfZCWWAL AVDAWYA~ 05153ഀ LOT 14 aiaar z vAC WAGE aro rz~cഀ LKP Engineering, Inc. 3" 6 AMM &W NW SCAMഀ CF VALഀ 'ഀ PA ow am Edwarft td (970) 946-9088 fm[ (9m) =-9089 EA[iE Comm, G7XptADO pM~YC MWഀ DATE OBSERVED: MAY 11. 2007 BORING NO. iഀ ELEVATION:ഀ Sഀ Sഀ Yഀ Aഀ DEPTHഀ BLOWSഀ Mഀ Mഀ DESCMP770N OF MATERIALഀ LABOR47CIRYഀ RELARKSഀ FEETഀ PERഀ Bഀ Pഀ AND SAMPLE LOCATIONഀ TEST RESUL7Sഀ Oഀ Lഀ Lഀ Eഀ T so//ഀ Brown, silty, clayey sandഀ 50/72ഀ DD= 121.0 pcfഀ - 5ഀ MC= 15.5 %ഀ -ഀ 501ഀ oഀ Brown, claystoneഀ DD= 127.5 pcfഀ MC= 8.7 Xഀ 10ഀ -ഀ GW O 71.5'ഀ - -ഀ - - - - - - - - - - - - - -ഀ - - - - - - -ഀ - - - - -ഀ AT TIME OF b LUNഀ -ഀ Refusal ® 13.5 feetഀ Ground Waterഀ 15ഀ Encounteredഀ 20ഀ LEGEND:ഀ 0 - 2-inch OLD. Cdiharnia Liner Sampleഀ ■ - Split Spoonഀ 24/72 - Drive sample blow count Indicates that 24 blowsഀ of a 140-pound hammer fa✓/ing 30 inches wereഀ required to d rive the California or the Split Spoonഀ Sampler 12 inches.ഀ DO - Natural Dry Density (pcoഀ MC - Natural Moisture Content (.t')ഀ -200 - Percent Passing Na 200 eveഀ LL - Liquid Limitഀ Pl - Plasticity Indexഀ OW - Ground waterഀ PROACr MOL.ഀ 015153ഀ LBP ENG01EERINGഀ INCഀ SUBSURFACE EXPLORATION LOGഀ ,ഀ .ഀ nUuw uഀ 1ഀ DATE OBSERVED: MAY 11. 2007 BORING NO. 2ഀ ELEVATION:ഀ Sഀ Sഀ Yഀ Aഀ DEP7Hഀ BLONSഀ Mഀ Mഀ DESCMP77ON OF MAMIUALഀ LABORATORYഀ REMARKSഀ FEETഀ PERഀ Bഀ Pഀ AND SAMPLE LOCA7701Vഀ TEST RESLIUSഀ Oഀ Lഀ Lഀ Eഀ Fill, consisting of topsoil, clay _ഀ ഀ o .15'ഀ -ഀ and grailഀ AT ENDOF& LUNGഀ -5ഀ -ഀ 50112ഀ oഀ DD= 127.4 pcfഀ Brown, claystone and sandstoneഀ MC= 12.5 Rഀ 10ഀ matrixഀ Refusal ® 13 feetഀ Ground Waterഀ -ഀ Encountered O 125ഀ feetഀ - 15ഀ 20ഀ 25ഀ LEGEND:ഀ 0 - 2-inch QD. California Liner Sarnp/e DD - Natural Dry Density (pcf)ഀ ■ - Split Spoon MC - Natural Moisture Content (X)ഀ 24112 - Drive sample blow count Indicates that 24 blows -200 - Percent Passing Na 200 Sieveഀ of a 140-pound hammer falling 30 inches were LL - Liquid Limitഀ requi►ed to drive the Califamia or the Split Spoon Pl - Plasticity Indexഀ Sampler 12 inches: Gw - Ground waterഀ A maser N4ഀ 05153ഀ L" ENGINEERINGഀ INCഀ SUBSURFACE EXPLORATION LOGഀ ,ഀ .ഀ n Nnഀ 2ഀ 3ഀ 2ഀ cഀ 0ഀ 1ഀ aഀ 0ഀ xഀ Wഀ 0ഀ kഀ -fഀ cഀ 0ഀ obiഀ -2ഀ Eഀ Vഀ -3ഀ -4ഀ 3ഀ 2ഀ cഀ 0 1ഀ bഀ Oഀ kഀ 0ഀ kഀ -1ഀ aa -2ഀ Cഀ Eഀ Uഀ -3ഀ -4ഀ Q 1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of Dork brown, daystone from. Baring No. 1 O 4 Feetഀ Natural Dry Unit Weight = 121.0 pcfഀ Natural Mature Content = 15.5 percent Q7X swell O 29 ksf Swell Pressureഀ at 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of Dark brown, dgWtone from. Boning Na 1 O 8 Feetഀ Natural Dny Unit Mteot = 127.5 pcfഀ Natural Moisture Content = 87 percentഀ Nn:ഀ LKP Englneeriig` Inc. S'wO,1CbnsdNaffw Teat Rand& ~ 15sഀ Cഀ O fഀ Oഀ Wഀ 0ഀ kഀ -1ഀ 9ഀ e -2ഀ Eഀ Uഀ -3ഀ -4ഀ 0. f 1.0 10 1Dnഀ AP V Jm PRESSURE - ksfഀ Sample of : Dark brown, da)etone from. Baft Na 2 O 8 feetഀ Natural Dry Unit WMIgiht - 1274 pcfഀ Natural Moisture Content = 125 percent 1.3X swell O 59 ksf swell pressureഀ rnഀ 05153ഀ EMP1 -1 vq a fh96 Im Lswell - Consolidation Test Results ESU.-ഀ 4ഀ Utl~ ~15ഀ InsulVail, «cഀ Post Office Box 2888ഀ Vail, Colorado 81658ഀ 970-524-3000ഀ Fax 970-524-3001ഀ Mr. Mitch Sturdeഀ Shaeffer Constructionഀ PO Box 373ഀ Vail, Colorado 81658ഀ HAND DELIVEREDഀ September 22, 2008ഀ PROJECT: Dayton Residenceഀ Beaver Dam Roadഀ Vail, COഀ SPECIFICATIONS:ഀ R Values- polyurethane spray foamഀ R-57 9" polyurethane spray foam to 117/8" exterior ceilings aboveഀ lower bedrooms that have decks aboveഀ R-57 9" polyurethane spray foam to 9 exterior ceiling at entry areaഀ R-46 7 polyurethane spray foam to 7 exterior ceiling above laundry roomഀ R-57 9" polyurethane spray foam to lower level deck exterior ceilingഀ R-57 9" polyurethane spray foam to 2 x10 mechanical room exterior ceilingഀ R-57 9" polyurethane spray foam to 117/8" cantilevered areasഀ R-38 6" polyurethane spray foam to rim joists through out the home as markedഀ R-25 4" polyurethane spray foam to I beams throughout the houseഀ R-51 8" polyurethane spray foam to 16" at perimeter roof area only at master bedroom onlyഀ R-22 3.5" polyurethane spray foam behind the in set TV in kitchenഀ R-35 5.5" polyurethane spray foam to 2x6 exterior wall cavity at the entry area as paintedഀ R-12 2" polyurethane spray foam to concrete wall in bedroom #Iഀ R-38 6" polyurethane spray foam to rim off mechanical roomഀ R-57 9" polyurethane spray foam to garage exterior and deckഀ All polyurethane spray foam area are marked with spray paint at the houseഀ 1140mഀ Rഀ Page 2 of 2 Shaeffer/Daytonഀ R Values-fiberglassഀ R-23 Blow-In-Blanket System fiberglass insulation (BIBS) to 2x6 exterior wallsഀ as marked on the wallsഀ R-23 BIBS to 2x6 chimney exterior wallsഀ R-23 BIBS to 2x6 garage common wallsഀ R-23 BIBS to 2x6 garage exterior wallsഀ MemBrain smart vapor barrier to exterior walls, garage common walls andഀ garage exterior wallsഀ R-47 BIBS to 117/8" garage ceilingsഀ R-32 BIBS to 7 garage ceilingsഀ R-47 BIBS to 117/8" mid floorsഀ R-38 unfaced fiberglass batts to 117/8" crawl ceilings with strappingഀ R-15 BIBS to 2x4 interior wallsഀ R-23 BIBS to 2x6 interior wallsഀ Foam all windows, doors and penetrationsഀ Rick Rogersഀ Branch Managerഀ 2ഀ COMMERCIALROഀ LOW TEMPഀ 1 Dഀ PRODUCT NAMEഀ STYROFOAM Square Edge Fluഀ Extruded Polystyrene Insulatior~~.ഀ 2 Manufacturerഀ The Dow Chemical Companyഀ Dow Building & Constructionഀ 200 Larkinഀ Midland, MI 48674ഀ 1-866-583-BLUE (2583)ഀ Fax 1-989-832-1465ഀ www.dowstyrofoam.com/architectഀ 3- Productഀ Descriptionഀ STYROFOAM* Square Edge insu-ഀ lation is an extruded polystyreneഀ board that meets the needs ofഀ the commercial foundation andഀ building floor slab market.ഀ STYROFOAM extruded poly-ഀ styrene has more than 50 yearsഀ of proven performance in wetഀ environments. The closed-cellഀ structure of STYROFOAMഀ Square Edge insulation resistsഀ water pickup, enabling it toഀ retain a high R-value** overഀ time - a necessary property inഀ wet, below-grade commercialഀ foundation applications.ഀ BASIC USEഀ STYROFOAM Square Edgeഀ insulation protects foundationഀ damp-proofing and waterproofing,ഀ especially during backfilling. Itഀ also provides a secondary barrierഀ against groundwater leakage.ഀ With STYROFOAM Square Edgeഀ insulation, freeze-thaw cyclingഀ of the foundation wall is mini-ഀ mized, reducing the potentialഀ for cracking. And a warmerഀ foundation can reduce theഀ potential for condensation.ഀ STYROFOAM Square Edgeഀ insulation can be used againstഀ commercial interior walls andഀ exterior foundation walls inഀ above- and below-grade applica-ഀ tions. STYROFOAM Square Edgeഀ insulation can be used underഀ the slab or over the deck orഀ subflooL STYROFOAM Squareഀ Edge insulation is suitable forഀ use in pervious, semi-perviousഀ and practically impervious soils.ഀ SIZESഀ Width and length:ഀ 2'x8'and4'x8'ഀ Thickness:ഀ .75", 1", 1.5", 2", 2.5", 3", 4"ഀ Edge treatment: Square edgeഀ Not all product sizes areഀ available in all parts of theഀ country. Contact your localഀ Dow representative for details.ഀ 4 Technical Dataഀ APPLICABLE STANDARDSഀ ASTM Internationalഀ • ASTM C578, Type IV -ഀ Standard Specification forഀ Rigid Cellular Polystyreneഀ Thermal Insulationഀ • ASTM C518 - Standard Testഀ Method for Steady-Stateഀ Thermal Transmissionഀ Properties by Means of theഀ Heat Flow Meter Apparatusഀ • ASTM D1621 - Standard Testഀ Method for Compressiveഀ Properties of Rigid Cellularഀ Plasticsഀ • ASTM C272 - Standard Testഀ Method for Water Absorptionഀ of Core Materials forഀ Structural Sandwichഀ Constructionsഀ tiding &ഀ C fistructiഀ • ASTM D696 - Standard Testഀ Method for Coefficient ofഀ Linear Thermal Expansion ofഀ Plastics Between -30°C andഀ 30°C with a Vitreous Silicaഀ Dilatometerഀ • ASTM E96 - Standard Testഀ Methods for Water Vaporഀ Transmission of Materialsഀ • Meets IBC/IRC requirementsഀ for foam plastic insulation;ഀ see NES NER 699ഀ is Factory Mutual Approved -ഀ Subject to conditions ofഀ approval as a roof insulationഀ when installed as described inഀ the current edition of the FMഀ Approval Guideഀ PHYSICAL/CHEMICALഀ PROPERTIESഀ STYROFOAM Square Edgeഀ insulation exhibits physicalഀ properties as indicated in Table 1ഀ when tested as represented.ഀ For chemical resistanceഀ properties of STYROFOAMഀ Square Edge insulation, seeഀ Table 2.ഀ ENVIRONMENTAL DATAഀ STYROFOAM Square Edge insu-ഀ lation is manufactured withഀ HCFC blowing agents, whichഀ have 94 percent less ozoneഀ depletion potential than standardഀ CFC blowing agents.ഀ STYROFOAM Square Edgeഀ insulation is reusable inഀ many applications and canഀ be recycled.ഀ Y A D I C 11ഀ Physical Properties of STYROFOAM SCILiare Edge Insulaഀ Pnepeety lrld tat Wa;;d-ഀ tionഀ Yaia,e 'ഀ Thermal Resistance"' per inch, ASTM 0518 @ 751 mean temp.,ഀ ft'•h-WBtu, min., R-valueഀ 5.0ഀ Compressive Strengthln, ASTM D1621, psi, min.ഀ 25ഀ Water Absorption, ASTM C272, % by volume, max.ഀ 0.1ഀ Water Vapor Permeancec", ASTM E96, perm, max.ഀ 1.1ഀ Maximum Use Temperature, *Fഀ 165ഀ Coefficient of Linear Thermal Expansion, ASTM D696, in/in•*Fഀ 3.5 x 10-'ഀ (1) R-values are consistent with criteria of ASTM CS78 and requirements of FTC R-value rule (16 CFR Part 460).ഀ (2) Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first.ഀ (3) Based on 1" thickness.ഀ l 6 **R means resistance to heat flow. The higher theഀ 'Trademark of The Dow Chemical Company s R-value, the greater the insulating power.ഀ r.ഀ Oഀ •1~ഀ _tzഀ Hഀ Wഀ iഀ Crഀ Qഀ 0ഀ 6Lഀ Oഀ Nഀ TABLE 2ഀ Chemical Resistance of STYROFOAM Sഀ quare Edge Insulationഀ Acid, inorganic, weakഀ Excellentഀ Acid, inorganic, strongഀ Excellentഀ Acid, organic, weakഀ Excellentഀ Acid, organic, strongഀ Goodഀ Basesഀ Excellentഀ Alcohols, including isopropyl alcoholഀ Excellentഀ Methyl ethyl ketoneഀ Not recommendedഀ Polyglycols, including propylene glycolഀ Excellentഀ Hydrocarbonsഀ Not recommendedഀ Saltsഀ Excellentഀ Insecticidesഀ Not recommendedഀ Keroseneഀ Poorഀ Mineral oil USPഀ Excellentഀ Naphtha (VMP)ഀ Not recommendedഀ Turpentineഀ Not recommendedഀ Beerഀ Goodഀ Gasolineഀ Not recommendedഀ Fruit juicesഀ Goodഀ (1) Explanation of ratings:ഀ Excellent= The plastic was unaffected for the duration of the test NOTE: This table should be used as a guide only. For designഀ Good = A very slight clouding or discoloration of the plastic. purposes, specific test data on the intended application mayഀ Pon, = Considerable changes in plastic during exposure, be needed.ഀ P os. te etching, discoloration, dimensional or weight changes.ഀ Not recommended = Severe attack of the plastic. Became softഀ and unusable after a few hours of exposure.ഀ FIRE PROTECTIONഀ STYROFOAM Square Edge insu-ഀ lation is combustible; protectഀ from high heat sources. Localഀ building codes may require a pro-ഀ tective or thermal barrier. For moreഀ information, consult MSDS, callഀ Dow at 1-866-583-BLUE (2583)ഀ or contact your local buildingഀ inspector.ഀ 5 Installationഀ STYROFOAM Square Edgeഀ insulation boards are easy toഀ handle, cut and install. Theഀ square edge boards are designedഀ to ensure energy efficiency andഀ minimize on-site cutting andഀ waste. Use a polystyrene-ഀ compatible adhesive to holdഀ the boards in place duringഀ backfilling. Apply caulk orഀ mastic to the top of the boardഀ to prevent water infiltrationഀ behind the insulation. Toഀ complete the installation, pargeഀ the above-grade portions ofഀ STYROFOAM Square Edgeഀ insulation to protect from solarഀ radiation.ഀ It is recommended that anyഀ masonry irregularities or jaggedഀ surfaces on the foundationഀ wall or slab be removed priorഀ to installation. Below-gradeഀ walls should be protected fromഀ moisture leakage and dampnessഀ prior to installation ofഀ STYROFOAM Square Edgeഀ insulation. Code-approvedഀ drainage systems should beഀ installed. Ensure foundationഀ drainage meets local codes.ഀ Contact a local Dow represen-ഀ tative or access the literatureഀ library at www.dowstyrofoam.com/ഀ architect for more specificഀ instructions.ഀ 6_ Availabilityഀ STYROFOAM Square Edgeഀ insulation is distributed throughഀ an extensive network. Forഀ more information, contact yourഀ local Dow representative or callഀ 1-800-232-2436.ഀ 7- Warrantyഀ Fifteen-year limited thermalഀ warranty.ഀ 8 Maintenanceഀ Not applicable.ഀ 9 Technicalഀ Servicesഀ Dow can provide technical infor-ഀ mation to help address questionsഀ when using STYROFOAM Squareഀ Edge extruded polystyrene insula-ഀ tion. Technical personnel areഀ available at Dow sales offices toഀ assist with any insulation project.ഀ 10 Filing Systemsഀ • www.dowstyrofoam.com/ഀ architectഀ • www.sweets.comഀ • For Technical Information: 7-866-S83-1111LUE (2583)ഀ • For Sales Information: 14800-232-2436ഀ THE DOW CHEMICAL COMPANYഀ • Building & Construction • 200 Larkin • Midland, MI 48674 • www.dowstyrafoam.com/architectഀ NOTICE: No freedom from any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer isഀ responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customer's workplace and disposal practices are in complianceഀ with applicable laws and other government enactments. Dow assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OFഀ MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.ഀ COMBUSTIBLE: Protect from high heat sources. Local building codes may require a protective or thermal harrier. For more information, consult MSDS, call Dow at 1-866-583-BLUE (2583) or contact yourഀ local building inspector. In an emergency, call 1-989-6364400.ഀ Building and/or construction practices unrelated to ins laden or housewrap could greatly affect moisture and the potential for mold formation. No material supplier including [low can give assurance that mold will notഀ develop in any specific system.ഀ Living.ഀ Improved daily.ഀ Printed in U.S.A.ഀ *Trademark of The Dow Chemical Companyഀ Form No. 179-04454-0404P&Mഀ WKAY182644.OM6ഀ SPEC-DATA' AND MANU-SPEC ARE REGISTERED TRADEMARKS OF THE CONSTRUCTION SPECIFICATIONS INSTITUTE. THE TEN PART SPEC-DATA FORMAT CONFORMS TO THE EDITORIAL STYLEഀ of the Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. 01998 ARCHITECTS' FIRST SOURCE. ALL RIGHTS RESERVED.ഀ i H SHഀ LD_ഀ N-BNdLY1S0'BONDED TO ORTENTED STRAND BOARDഀ PRODUCT DESCRIPTIONഀ Fi Shield=NB Is a rigid.roof insulation composite panel. composedഀ of`~a closed cell polylsocyanurate foam cote bonded during theഀ manufacturing'process to fiber reinforced facers on one side andഀ either 7/16" or 5/8" oriented strand board (OSB) on the other;ഀ or manufactured:off-fine using an FM approved glueing adhesive.ഀ „ FEAT6hE$ AND BENEFITSഀ k Manufactured with NexGen ChemistryTM - Zero ODR CFC Freeഀ • 'A superlar.combinatlon of high Insulating properties and/or nallableഀ ' surfate.,- 'ഀ 5ultable for new construction and re-roofing on both commercial andഀ r~sidentlal projects,ഀ Incorporates APA-TECO Rated Exposure 1 Oriented Strand Boardഀ f~iahufactured"on line with a routed edge to allow for expansion ofഀ j the OSBഀ Al'so'avaliable as a non-routed panel for standing seam metal systems.ഀ H-Shield .NB is also available bonded to CDX plywood (various sizes),ഀ manufactured in an off-line process.ഀ Avallable with FSC Certified OSB on Plywood upon request.ഀ PANEL CNARACTERIMCSഀ AyAilable size is 47.1/20x 95 1/2" when routed on line. Thickness ofഀ 1.5" (38rrtt } to 4.5" (115mm)ഀ Available In 4'xB' when non-routed In thickness of 1.5" (38mm) toഀ r 4~5" (115mri+):ഀ ASTM C1289.06, Type V,ഀ APPUOTIONSഀ i 1 ShlefM6 with 7/16" OSB is suitable for use with heavyweightഀ shingles and standing seam metal roof systems.ഀ H-Shield-Nh with 5/8" OSB Is suitable for use with the and slate roofഀ systems.ഀ Single-Ply :Roof.; Systems Ballasted, Mechanically Attached, Fullyഀ Adhered. (For high wind speed warranty - see Individual single-plyഀ maഀ h4facturer approvals and listings.)ഀ VAPOR RETARDERSഀ The`incorporation' of a '.vapor barrier or retarder within theഀ ropfin assembly is highly recommended 'when the?project;Isഀ located In Zones'" as determined . by. the Internationa! Codeഀ Council Dept of:Energy NW'Natiot ell Ub of the.United 'StOesഀ (map is located, on www.poiylso.org).: Consult a Ilcel sea design.ഀ pro essional,'dichltect or engineer. to establish whether or not aഀ vapor barrier is necessary and .to specify its type and. location.,ഀ i This is especlally;important during the construction phase whereഀ excessive moisture drive is present. Hunter Panels recommendsഀ that a`dew ppoint calculation be performed. This calculation isഀ ' based on'; the building's interior relative . humidity, Interiorഀ temperature conditions and outside temperatureഀ fluctuations: Excessive moisture migration will potentially damageഀ iഀ NEXGENഀ H-SHIELD-NB THERMAL VALUESഀ (INC E$) (MM) R Vn UE- SPANAB LITYഀ the system and cause unwanted condensation.ഀ SNiMGLEs, TII.Es, SLATE, METAL AND MEMBRANE ROWING'ഀ H-Shieid-N8 is, installed, wood side up, over metal,,wood'orഀ structural roof decks. Hunter SIP/NB Panel Fasteners areഀ required to secure the M-Shield-NB to the roof deck: Woodഀ blocking, if necessary should be equal in thickness to the H-ഀ Shleld-NB, Is installed along the eaves and rake edges of theഀ roof. The roofing system. is then installed according to theഀ manufacturers recommendationsaഀ 888-746-1114 WWWഀ H-SHIELD-NB CODES AND COMPLIANCES FASTENING GUIDELINESഀ - E: pla, ! y5t X ~ t - ~'t43Tt>S i3¢i r JS` J .r I <.5t r eT,yr i' + ~ a~ ~E' "E~5ഀ ~r .4 n r t! 1 fr, ! t,Jt '1*-~,a ,Stഀ ' ~,lY 1~ ~ t , r ~ dt 4,~ ~,a'~ a ~ rtat std z> ~ ~ t ^ # , u ` •ഀ ~i,i~er C a tx~ r rr Ct'ഀ 4 s' S } :r f Y 5 1+5~ .~c t ~~i .1 a 'ഀ S. ! 5 y~ x 1~ 41 'tF # . ? "ib $ "W11ഀ t¢ il(ri't ~i48) $ecrlo~ ;zao3 sUIl~lt} ;oltlc~i§ $ t ► G~w~ c n f/~! yഀ INഀ d y l ,t v'•4`r~'xg r.. , t' c,S,sl~ ~'Y. ~tl'rc,.>~i I:fi a:,1fi! `xtx i,.a r',tx~ vഀ KAR .t c ~^'4t v S, }t ~ c - _ a .ti .;i y a~s1 t,•°~'tis' +ഀ Y, t`er~Sl~t~tlb yH~f I9yl~~k~ v ,1". `1~ }ഀ ~d r l tY. f i t 7~i 9ഀ POLYISO FOAM CORE r t nk j yഀ ~L r pkr~!Fy, ~ ,{Tt,a~~t er. r z { k , . r t tat' ONLYഀ 'ഀ S-E: ,St. S8 Y~' yu,yl•'S ✓ y d i s. t `1 x ,ഀ rM~ r ~ tഀ Mഀ ~~"t"`I e1 ` k it < kf. ,:f J,3j fit Yi f 4~ k s e y V"~~'.'r 6 Tl .t v!ഀ 0" 790)ഀ l 4}~Sr2~3`~¢a ~Iഀ 4'-'1~= :.fm~~ '~•r. ~~r Yz1Y~~e'~t~~r~~}p~.ഀ !~''t ~y.~ rA ~ ° ? x ' a'~ ~r3 v`~:7+ 4 x , r h ~S X'1 ~1~~; , ; F1~7 v~~ ~ f~ ~i QS~r~-~q'~~1`~9,' }ഀ 4-f5 Ry3sf r'r l~' i c rഀ 8011ഀ ' 'kF'~~ Y ~I 10$4~A ~1 ~,~V} 'r 2 ' SiE.'!J~'~[ t I:~:` r'4„~y{ t4 i ;4MSt~J f!'E ~tഀ r?jk 1;k f y~yG or r F AS M l 8 <j~~ ({~~r'tഀ i ~'~,jl(rkEV k~tt ILS a/y 1', s j~~~B f {.tF`~~ S ( F ~~ty f ! 11.. t ~t~ ~~,7f7{ lr 1 yJ ~1Y ~7(YSA~yI ~t n ~l •7f~/ഀ 1 J. 1 i3 L~~B r r ffy P47k~, I:~ 't ~r .pF.ഀ _v~-5ഀ tCa I .1~~1r~ ;„~1i 14t~~ ph~E.glasat :~`++rYUva~Q"4S,i)14n MV 209 5` ~<'~°hfy4?11~1eഀ N I ` f Z 5ഀ 4f,'Y~ i~~t~1ഀ e fJ t~~~i~-'~ -k~'y~i!'~ f~t ~?f?•#t tJ° ~ a ar't tl~e; ~ ~r bSfcd'v~-5 rlng py~ fഀ r ` Y _:`t ~ ~ .:11 :•l~~(S y~~~ ,y~, E)~M ,t ~AS~` L} $I i y ( 1 E , s C ~ഀ F/~"s• y ;i~ f .4S1E~f E r 1 Y Q?J! Yli A Mt' 47 rrt tY t r F iഀ ~ ~ M1 ~ k I Y! C 1 fief `J) r Iഀ FM ' ZY ' ,fie 0~ti~~ , y $i~ik V ?opetl A TNT' 84 <4~ഀ FNfkj ~ r e ro >~d k R9gr, w, A 1 ~1Je k i- y-ഀ a ad i ~ r~ > !ഀ or~jiz E t{t' o M,,, 400ഀ 30ഀ ` rUf ~ read r tore' 10a~ 0 2'50 F . sഀ (sbJ ?o (~~of&pp gv~ d~~n f~t~ierrt Perry ai~+jpnsv, ; "ഀ '26,Pഀ itlG'l~Iu rഀ r r > S ~'y.nlivr isr€iV,S.J.•: ,t by tഀ F PTOഀ yr J , ,ഀ CTS BY HUNTER:ഀ r ,c L .•~'r' ' Y$• ( ..C 'F`~ rCti ` y~rt1 ,Yk y+{'l+~ayf N`~i 1 1 1 ~'j ! .7 ~ `-.'7 'v• } f• ~ ';!t ~ e t pig _x fy r ~ ~ }'7' 77ഀ rഀ ! . C Jt ~ Gഀ WARNINGS Aഀ Iils s it + ; n}~750 QpNOED f0 FOJL ,ഀ ACERBഀ f > A~yi x LYFS+UF 'pr}f43itDfcKഀ dk~~,~fj{ S 3i f t vഀ f9 4 f a k a r Y t > [17 ! Tt „ 7tR Cil 155, rAW F0~ < cഀ d .{f,9 f. J'~^V+ c t'` r z 1 j~~ fi~ r i A71ONS r rഀ at p{ } t l) ter.; F y i,~~y` r 1~t~ ~y~ss 15 v r Y :12 t. ! fഀ ~j~j xc tit}t~ - Y.r. Y h. ~i `~.q{e • _Aµµ~jj~~P 't ? 1 •i ,r~ f 1,~ i <v ~Iഀ I H Yl} Vs i~. ~l. SIY t l i t e. ; 7. 2 •'l Y~f,CU 4 i 2 ~r f. , ,iഀ Cr6 {~~1OJJ1~ഀ F7AER kഀ r' t ~ u s7 VCR3 1 h,C ;it 1 't `mac"t # :'{rt Sr' .i e r I1f'~x j !fi ~i, Yf k ~ jy ///-~~~s`,fyf~'r~t( yet + ;":T F r t r , 1 t Vഀ u eഀ e!<,r, , ,sr C { !tA@ 7- t 'f ..:•T kf.,E{A _.YC~ "Y.J.'S! 7~ Cbi1'(~ Cil ~$fJ ,~Cഀ DR... ,fir°, a k fi > YINഀ I i u t .;'1 ~ yy (y{ yq t pgy,y.~ ~jഀ ' Q ` s at ,?S {O('' aolyl501 I' t r ~ 11' 9A '1`~ s TKtN PAYVfL „ഀ ♦f!h✓~~~ ttQ !a 14 r~ r y3 f . k n Cr~t~ ~r j Z 7~ ~C~ ,r ,yJ ~ t4 {,<r t, . t rl~ 4 r rഀ I rt t jf lit r( i t e 3 ~tyf f f 4t 1 r! t yI tഀ ht t .i 1;}.1; f t _ R tt f I s 1 ~.r + ;r Iഀ Neon,,",ഀ ~ i {{yy y J h 1 ,ഀ lx1~~31~~Qഀ ~ C h~ t t i 1, rr } ) r,~ ~s t ti r rഀ A,ഀ > ~r ~ ! rp,ഀ a r }ഀ ~;t r I ~ a a t ~ l) `'~i ~ y[E~"~7 f3yak~~ 5ഀ i 5 jE • i 1 ~`'J r Yet n" `~r4rd\ \ ,FI~UN4JT~r1 1"rt~af-}+t74; ,1 Y 0M4,ഀ iഀ X®rഀ Yla rt , < rar n y I. , t t ~t r 1.K ) S 1 : !ഀ r f _ r t fr~ T I#~t 1i~ t~ j r r;. t t Nഀ o t M ~~~~URl fq ~ciVU,ഀ j x u~'~ i ~ MiXB(1 $OIIfCCS ~ ~ + ,1. .rt cI Y r r t .'~,i ,i 1.ഀ ) t PAP ~ sI K ~ .«n, •„ye w,rH... ai ~ ~ ~ t ~ , I Hjl~ Ellഀ near e . i ING,tQ~ll pഀ rw ea. K i, 1' tഀ FSC wmn. src wsmoanm `fiA,N~IN pA~a ~OOkkll U~'i ,Fഀ . _ ~I:AKE'~CItYf:'~l~ SM1tHKlf"I,R~,PA _ t,ഀ ta>q~ഀ H U N T E R P A N E L S S i P/ W D F A S T E N E Rഀ STAR / SFഀ DRIVE Hഀ (FREE DRIVER IN Iഀ 3/16" SHANKഀ . DIAMETERഀ MADE OF HEഀ TREATED STEELഀ DRAMATICAIഀ INCREASE[ഀ STRENGTH Aഀ DRIVABILITഀ ULTRA COATEDഀ UNMATCHED Cഀ ROSION REST'ഀ ANCEഀ The Hunter Panels SIP/WD Fastener is intended to mechanically attachഀ H-Shield NB, Cool-Vent and Cool-Vent ll to woad substrates. The Hunter Panels SIPADഀ Fastener has the following features:ഀ • FM APPROVED PLATES NOT REQUIREDഀ • WAFER HEAD ELIMINATES NEED FOR WASHER AND OFFERSഀ DRAMATICALLY INCREASED PULL-OUT VALUEഀ • 100% AMERICAN MADEഀ • FAST, ONE-STEP INSTALLATIONഀ • NO PRE-DRILLINGഀ • MULTIPLE BITS INCLUDED IN EACH PAILഀ TEST DESCRIPTION TYPICAL VALUEഀ Pull-through (lbs) 630ഀ a OSP,ഀ , W-Aഀ Pull-out (lbs).ഀ Spurഀ 1/2" plywood 442ഀ "ഀ 150ഀ 5/8" plywood 459ഀ _ഀ Boardഀ 3/4" plywood 710ഀ Douglas Fir (1" pen.) 768ഀ L 5,d su7(cഀ Fasteners should never be struck with a hammer during instaflatlon.ഀ Wx_jഀ PHYSICAL FASTENERഀ DATA LENGTH.ഀ THREAD DIAMETER:ഀ .240ഀ SHANK DIAMETER:ഀ .190ഀ 13"ഀ 14ഀ •b?ഀ H U N T E R P A N E L S S I P/ S D F A S T E N E Rഀ The Hunter Panels SIP/SD Fastener is intended to mechanically attach H-Shield NB,ഀ Cool-Vent and Cool-Vent it to corrugated metal decking. The Hunter Panels SIP/SD Fastener has theഀ following features:ഀ • FM APPROVED - PLATES NOT REQUIRED STAR ! SPIDERഀ • PULL OUT VALUES FOR METAL (FREE DRIVER IN HEADഀ eox)ഀ • WAFER HEAD ELIMINATES NEED FOR WASHER AND OFFERSഀ DRAMATICALLY INCREASED PULL-OUT VALUEഀ • MULTIPLE BITS INCLUDED IN EACH PAIL 3/ 16" SHANKഀ • 3 THREAD LENGTH - LARGEST IN THE INDUSTRYഀ • 100% AMERICAN MADEഀ • FAST, ONE-STEP INSTALLATIONഀ • NO PRE-DRILLINGഀ MADE OF HEATഀ TREATED STEEL FORഀ DRAMATICALLYഀ INCREASEDഀ STRENGTH ANDഀ 1~ TEST DESCRIPTIONഀ TYPICAL VALUEഀ DRIVABIEITYഀ ti,'1"Ni Pull-through 0bs)ഀ 630ഀ _ Poll-out (lbs):ഀ ISCIഀ 13oant 22 gauge metalഀ 510ഀ - - 18 gauge metalഀ 920ഀ ULTRA COATED FORഀ UNMATCHEDഀ rat t. Fasteners should never be struck with a hammer during installation.ഀ CORROSIONഀ RESISTANCEഀ Metalഀ PHYSICAL FASTENER THREAD 3" OF THREADഀ DATA LENGTH LENGTH WITH 1/4' MAJORഀ DIAMETERഀ THREAD DIAMETER:ഀ ,240ഀ SHANK DIAMETER: 51 2" 3" SPADE POINT FORഀ 190 6" 3° / FAST DRILLINGഀ 61/2" 3• oഀ 14•ഀ <_97ഀ 4ഀ INDEPENDENT TESTING &ഀ INSPECTION SERVICES INC.ഀ 12084 VASEEN CT. ,ഀ CONIFER, COLORADO 80433ഀ 303-674-7560ഀ FAX 303-674-7560ഀ Town of Vailഀ OFFICE Page 1 of 3ഀ COPYഀ OBSERVATION REPORTഀ Client: George Shaeffer Construction Co. ITIS Job No. 091108 Date: 9-11-08ഀ Project:ഀ Dayton Residenceഀ Location: COഀ Inspector:ഀ David L. Sturgeonഀ This report package contains information concerning specific tests and inspections of structural steelഀ welding, structural bolting, structural sprayed fireproofing, and/or nondestructive testing.ഀ The specific criteria utilized in judging the degree of conformance for each area of inspection areഀ contained on each individual inspection form.ഀ Also included may be ITIS' "List of Outstanding Discrepancies" (O.D. List). The O.D. List will beഀ consecutively numbered for each page issued throughout the duration of the project. Each individualഀ item listed will also be consecutively numbered.ഀ If there are any questions regarding the content of this report, please feel free to contact ITIS at yourഀ convenience.ഀ David L. Sturgeon jഀ Presidentഀ ICBO Certified Inspector X1138247-85ഀ AWS QC-1 #82122691ഀ Resident Level IIIഀ 4.ഀ INDEPENDENT TESTING &ഀ INSPECTION SERVICES INC.ഀ 12084 VASEEN CT.ഀ CONIFER, COLORADO 80433ഀ 3034747560ഀ FAX 303-6747560ഀ Page 2 of _ 3 _ഀ FIELD INSPECTION REPORT FORMഀ INITIAL VISUAL INSPECTION OF WELDINGഀ Inspector: David L. Sturgeon MS Job No. 091108 Date: 9-11-08ഀ Field Made Welds: R Shop Made Welds:ഀ Type of Weld Inspected: Fillet .X Groove Otherഀ Type of Component (ie: column, beam, girder, moment welds, etc.) As Recordedഀ Applicable Code or Standard: AWS. IBC and Project Standardsഀ AREAS OF INSPECTIONഀ Level or Elevation: Main Level 3 of S205- Bolted Connectionsഀ Grid Line Location(s) encompassing the area(s) inspected/tested: A-C/North:~,of 1-lineഀ Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copyഀ of the O.D. List if applicable. The bgam to--girder, beam to beAM and column to beam con-ഀ nections were found conforming to snug-tight, A-325N criterial.ഀ Level or Elevation: Main Level Bolted Connectionsഀ Grid Line Location(s) encompassing the area(s) inspected/tested: 1-5/D-Gഀ Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copyഀ of the O.D. List if applicable. The beam to beam and column to beam connections wereഀ found confomring to snug-tight A-325N criteriaഀ Level or Elevation: Main and Upper Levels 7 of S204 Welded Bracingഀ Grid Line Location(s) encompassing the area(s) inspected/tested: E and .4.ഀ Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copyഀ of the O.D. List ifapplicable. The field welded connections were found of conforming sizeഀ and AWS quality.ഀ INDEPENDENT TESTING &ഀ INSPECTION SERVICES INC.ഀ 12084 VASEEN CT.ഀ CONIFER, COLORADO 80433ഀ 303-674-7560ഀ FAX 303474-7560ഀ Page 3 of 3ഀ FIELD INSPECTION REPORT FORMഀ INITIAL VISUAL INSPECTION OF WELDINGഀ Inspector: David L. Sturgeon TTIS Job No. 091108 Date: 9-11-08ഀ Field Made Welds: Y_ Shop Made Welds:ഀ Type of Weld Inspected: Fillet X Groove Otherഀ Type of Component (ie: column, beam, girder, moment welds, etc.) As Recordedഀ Applicable Code or Standard: AWS, IBC and Proi ect Standardsഀ AREAS OF INSPECTIONഀ Level or Elevation: Level One SSX 6 and 7 Cantileversഀ Grid Line Location(s) encompassing the area(s) inspected/tested: Garage, East and West Wallsഀ Provide information re: conditions of nonconformance. Include the Q.D. item number and attach a copyഀ of the O.D. List if applicable. The modified top of wall connections shown in the referencedഀ SSK's have been completed and were found conformingഀ Level or Elevation: Foundation Column Base Connectionsഀ Grid Line Location(s) encompassing the area(s) inspected/tested: Crawl Space Areaഀ Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copyഀ of the O.D. List if applicable. The column base anchorages were _found conforming whereഀ viewed, X-bracing included.ഀ Level or Elevation: Level ONe SSK05 Beam Pocket Connectionsഀ Grid Line Location(s) encompassing the area(s) inspected/tested: East Garage Wallഀ Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copyഀ of the O.D. List if-applicable. The pocket connection was found complete.ഀ 1ഀ Tarn of Vailഀ OFFICE COPYഀ d;ഀ eഀ iഀ Monroe & Newellഀ Engineers, Inc.ഀ Vail, Coloradoഀ Denver, Coloradoഀ Frisco, Coloradoഀ September 11, 2008ഀ Zഀ K. H. Webb Architectsഀ 710 West Lionshead Circleഀ Vail, CO 81657ഀ Attn: Ms. Millie Aldrichഀ Re: Dayton Residence inspection items (M&N #7291)ഀ Dear Millie,ഀ Monroe & Newell Engineers, Inc. has received a copy of the inspection report onഀ the framing inspection for the Dayton Residence by the Town of Vail Buildingഀ Department dated September 10, 2008. The following list addresses specificഀ structural items from that report as requested by George Schaeffer Construction.ഀ Items on the report not noted here will be addressed by the contractor.ഀ Item #1: The (3) 14" LVL beam noted on sheet S105 along gridline 4 fromഀ C to D may be replaced with (3) 11 7/8" LVL since the roof willഀ not have the stone pavers originally specified for the project.ഀ Item #5: The detail 1/S104 was not provided since the stringer for theഀ custom stair (designed by others) has not been finalized. Theഀ detail will be provided once the stringer information can beഀ provided to us.ഀ Item #6: Anchor bolts at shear walls must be provided as noted on theഀ shear wall schedule. Post-installed anchors may be 1/2" diameter xഀ 4" embedment expansion anchors in lieu of the diameterഀ anchor bolts specified.ഀ Coloradoഀ A Component of The American Institute of Architectsഀ Platinum Sponsorഀ 15 Consecutive Yearsഀ 619 Main Street • Suite 7 • P.O. Box 295 • Frisco, Colorado 80443ഀ (970) 668-3776 • FAX (970) 668-3789 • email frisco@monroe-newell.comഀ 4ഀ Item #7: The "D" shear wall shown near grids 2B on sheet S203 will needഀ %2" plywood each side as noted in the shear wall schedule or as aഀ contractor's alternate could have 5/8" plywood sheathing appliedഀ to one side of the wall to doubled up 2 x studs at l'-4" spacingഀ fastened together with two rows of 16d nails at 12". If this optionഀ is chosen, the sheathing fasteners should be at 2" spacing at panelഀ edges, staggered to avoid splitting the studs. Fasteners not atഀ panel edges may be spaced at 12"ഀ Item #9: Section 13/5203 was not deleted and the framing in this areaഀ appears to be installed in substantial conformance with theഀ construction documents. The comment from the inspector isഀ unclear. We will address any issues in this area once we receiveഀ clarification.ഀ Item 410: Attached are details SSK-1 through SSK-9 issued during theഀ course of construction. The last full plan issuance was delta 5ഀ dated October 22, 2007. The attached details reference the planഀ sheets from the last issuance of construction documents.ഀ If you have any questions or comments, please call.ഀ Very truly yours,ഀ MONROE & NEWELL ENGINEERS INC.ഀ Mark Gee, P.E.ഀ Associate Principalഀ Monroe & Newell Engineers, Inc. 2 Dayton Residenceഀ September 11, 2008 (M&N# 7291)ഀ 14. RE: ARCHITECTURAL DR/ഀ s 103 FRAMING DETAILS.ഀ ~7ti`~1'nN 15. ALL EXTERIOR kqALLSഀ FLOOR TO FLOOR OR FLഀ - - t1 L L-FL- 04R--JO4-ST5ഀ I1/8" BCI/9m. UNLEഀ NOTED OTHERJJI5E.ഀ ഀ q dBldJ6'1~, ~ iഀ ~ i 20ഀ 20 Q,, aഀ w II 7/8" LVLഀ RIOR ----1------------- UP--ONL---Y-- -t~------------------1-------ഀ ABOVEഀ KOX26ഀ - - - - - - - - - -ഀ 2X8 o,Lഀ xഀ <3)-2X8ഀ H55 4X4XI/4 (3)-2X8ഀ d (2)-11 -7/8" BGIഀ AT 1'-4"ഀ 1/4" STEEL SADDLE IIഀ OIL Ia8'-3" WELDED TO BEAM EB 20ഀ ~UP ONLYഀ Xഀ 0 _ഀ (3)-11 7/5 LVLഀ 4ഀ r F-ഀ _ Iഀ 20 - Q (~)-2X6 UP, 7771717ഀ 11* /ഀ HSS 4X4XI14 DOWN -ഀ ~:C = Qഀ S i P-'IPSON-ഀ 8 UP HU HANOERഀ HSS 4X4X3/8 ONLYഀ Up 20 HSS 4X4X318 i Jഀ ONLY IOX___ 30 LVLഀ - - - - J.ഀ LLI 0 r hഀ Y a O' DUNG vET 5LA8 / i ; t wഀ LLJ,ഀ I f WITH 45 AT- I- EAGH I I iഀ Xഀ I Y, TOP s1D- TOM % 1 I Wഀ C"Oഀ JN L~J 4'(. (~lLUFxl -ഀ -ഀ p <1a8'r0 rte-ഀ YdIOX22 ( NT NUOUS) - - - = `tഀ 3X3X1/4 -ഀ -HS513X5X114 H55ഀ I/2"ഀ 3 m UP ONLYഀ 20 I- (3)-II 'U8'LVLഀ - Sഀ JOB '72--uഀ Monroe & Newellഀ Engineers, Inc. SHEET NO. OF ~qഀ CALCULATED BY DATEഀ CHECKED BY DATEഀ iഀ Monroe & Newell JOBഀ Engineers, Inc. SHEET NO. _ OFഀ CALCULATED BY DATE J' oഀ CHECKED BY DATEഀ cr.Al Fഀ Monroe & Newellഀ Engineers, Inc.ഀ JOB 12ഀ SHEET NO. / OFഀ CALCULATED BY DATE (9 -1ഀ CHECKED BY DATEഀ crniഀ ._.w.. K'" ©3'ഀ G I n 2 I'-nA 'Cഀ Ek -h"ഀ Monroe & Newellഀ Engineers, Inc.ഀ JOB ` 2.°Eഀ SHEET NO.ഀ CALCULATED BYഀ CHECKED BYഀ OFഀ DATE --Dr~ 1 -0 1 p Lഀ DATEഀ Monroe & Newellഀ Engineers, Inc.ഀ JOBഀ SHEET NO.ഀ `l 2-R lഀ OFഀ CALCULATED BY A " DATE 1 ©.11 9!,v7ഀ CHECKED BYഀ SC:AI Fഀ DATEഀ t C3~~~ Qഀ A wഀ Monroe & Newellഀ Engineers, Inc.ഀ JOB 7Zഀ SHEET NO.ഀ OFഀ CALCULATED BY- im A- DATE :3 N/ Q Sഀ CHECKED BYഀ crni Fഀ DATEഀ LQ~-ഀ eഀ ഀ I LAഀ V-41.ഀ 4AIഀ S~vt_6Ot~1 LooiG- ~0ഀ 6 1:6ഀ S 1 3ഀ ct(~~®, l_ഀ Mdഀ s Q 7ഀ nഀ PAM IM 904-11Ci-Ch.-l--i tp,-iഀ A Monroe & Newellഀ Engineers, Inc.ഀ JOBഀ SHEET NO. OF /ഀ CALCULATED BY DATE 1 ~~aഀ CHECKED BY DATEഀ ccni rഀ LKP : Engineering, Inc.ഀ CIVIL/GEOTECHNICALഀ SOIL AND FOUNDATION INVESTIGATIONഀ FOR THEഀ PROPOSED DAYTON ADDITIONഀ LOT 10, BLOCK 2, VAIL VILLAGE, 3RD FILINGഀ 344 BEAVER DAM ROADഀ TOWN OF VAILഀ EAGLE COUNTY, COLORADOഀ PROJECT NO. 05153ഀ SEPTEMBER 19, 2005ഀ ~ഀ ഀ CMDഀ Wഀ 29526 -ഀ Vt4ഀ 4ഀ fA6~ ~ഀ "ഀ ~~~~~A~ddtlAFi4VSha'a4M'~~`6~ഀ PREPARED FOR:ഀ MR. KYLE WEBBഀ KH WEBB ARCHITECTS, PCഀ 953 S. FRONTAGE ROAD WEST, SUITE 216ഀ VAIL, CO 81657ഀ P.O. Box 2837, Edwards, CO 81632, (970) 926-9088 Tel, (970) 926-9089 Faxഀ TABLE OF CONTENTSഀ EXECUTIVE SUMMARY 2ഀ SCOPE OF STUDY 2ഀ SITE DESCRIPTION 3ഀ PROPOSED CONSTRUCTION 3ഀ FIELD INVESTIGATION 3ഀ SUBSURFACE SOIL AND GROUNDWATER CONDITION 4ഀ FOUNDATION RECOMMENDATIONS 4ഀ SLAB CONSTRUCTION 6ഀ RETAINING WALLS 7ഀ UNDERDRAIN SYSTEM 7ഀ SITE GRADING AND DRAINAGE 8ഀ LAWN IRRIGATION 8ഀ LIMITATION 9ഀ FIGURESഀ LOCATION SKETCH DRAWING NO. 1ഀ SUBSURFACE EXPLORATION LOGS FIGURE NO'S 1 & 2ഀ SWELL/CONSOLIDATION RESULTS FIGURE NO'S 3 - 5ഀ PERIMETER DRAIN FIGURE NO. 6ഀ 2ഀ EXECUTIVE SUMMARYഀ Ground water dewatering will be necessary for the construction ofഀ the proposed addition.ഀ 2. The proposed addition should be supported with conventionalഀ type spread footings, designed for an allowable soil bearingഀ pressure of 2500 psf. They should construct the footings on theഀ undisturbed, clayey-gravelly soil and/or bedrock, below all fill andഀ topsoil. See Foundation Recommendations for otherഀ alternatives.ഀ SCOPE OF STUDYഀ This report presents the results of a subsurface Soil and Foundation Investigationഀ for the proposed Dayton Addition, Lot 10, Block 2, Vail Village 3rd Filing, Town of Vail,ഀ Eagle County, Colorado. The purpose of the subsurface soil and foundation investigationഀ was to determine the engineering characteristics of the foundation soil and to provideഀ recommendations for the foundation design, grading, and drainage.ഀ LKP Engineering, Inc.ഀ SITE DESCRIPTIONഀ Lot 10 is a 0.4724-acre lot, at 344 Beaver Dam Road, in the Town of Vail, Eagleഀ County, Colorado. The topography is moderate to steep. Drainage is to the north andഀ northwest. Vegetation on the lot consisted of pines, grass and serviceberries. To the northഀ of the existing residence there is a pond, wet areas and small stream, and thick, wetlandഀ type of vegetation. The lot has an existing residence and a gravel surfaced driveway.ഀ PROPOSED CONSTRUCTIONഀ We understand that the proposed residence will consist of a wood frameഀ construction addition, on a concrete foundation. The proposed addition will be on the eastഀ and north sides of the existing building. Loads are anticipated to be light, typical ofഀ residential construction.ഀ If the finalized plans differ significantly from the above understanding, they shouldഀ notify us to reevaluate the recommendations of this report.ഀ FIELD INVESTIGATIONഀ The field investigation conducted on August 10, 2005, consisted of boring,ഀ logging and sampling two test borings. The test boring locations are shown on Drawingഀ No. 1. Drilling of the test borings was done with a 4-inch diameter, continuous flight, aഀ power auger, on a truck mounted drill rig. We show the soil profiles of the test borings onഀ LKP Engineering, Inc.ഀ 4ഀ the Subsurface Exploration Logs, Figure No's one through three. Soil samples forഀ laboratory soil analysis and observation were taken at selected intervals by advancingഀ Standard Split Spoon and California Samplers with a 140-pound hammer, falling 30ഀ inches.ഀ SUBSURFACE SOIL AND GROUNDWATER CONDITIONഀ The soil profiles encountered in the test borings were fairly uniform. Boring No. 1ഀ consisted of five feet of fill over eight feet of brown, gravelly, sandy clay over two feet ofഀ weathered bedrock over five feet of claystone bedrock. Boring No. 2 had three feet of fillഀ over three feet of gravelly clay over 12 feet of reddish brown, clayey, gravelly sand overഀ two feet of claystone bedrock. Ground water was encountered at 11 feet in both borings.ഀ We sampled the soil in the test borings at random intervals. The soil samples wereഀ brought to our laboratory for observation and analysis. They were tested for natural dryഀ density, natural moisture content and swell/consolidation. The results can be seen onഀ Figure No.'s 3-5.ഀ FOUNDATION RECOMMENDATIONSഀ Due to the high ground water elevation extreme care should be taken during theഀ design and the construction stages on this lot. Ground water and softer soils wereഀ encountered in Test Boring No. 1. One alternative for the proposed addition is to beഀ supported with strait shaft piers, designed for an allowable end bearing pressure of 10,000ഀ psf. The piers should be imbedded for a minimum of twice the pier diameter into firm,ഀ bedrock. Due to the high ground water level, the piers would have to be incased withഀ LKP Engineering, Inc.ഀ 5ഀ inspected by the undersigned engineer, prior to concrete placement.ഀ Another alternative for the proposed addition is to be supported with conventionalഀ type spread footings, designed for a maximum allowable soil bearing pressure of 2500 psf.ഀ The footings should be placed on the undisturbed, clayey-gravelly soil and/or bedrock. Forഀ this alternative, ground water dewatering and improvement of the foundation subgradeഀ might be necessary. The ground water elevation can vary, and it is possible it will rise asഀ high as the proposed foundation. A minimum of two feet of separation should beഀ maintained between the ground water and the bottom of the footings.ഀ The high ground water elevation can impact the foundation bearing soils. Groundഀ water dewatering will be necessary. We recommend an underdrain behind every step inഀ the foundation.ഀ We also recommend two feet of gravel under the slab on grade areas. The gravelഀ should be connected with the perimeter drain. More detailed recommendations for theഀ underdrain system can be provided once the foundation and grading plans are completed.ഀ We recommend minimum width of 16 inches for the continuous footings and 2ഀ feet for the isolated footing pads. Continuous foundation walls should be reinforced topഀ and bottom to span an unsupported length of at least 10 feet.ഀ We recommend a minimum of 48 inches of backfill cover for frost protection ofഀ the footing subsoils. The foundation excavation should be observed by the undersignedഀ engineer to verify that the soil conditions encountered during construction are asഀ anticipated in this report. The foundation excavation should be free from excavationഀ spoils, frost, organics and standing water. We recommend proof-rolling of the foundationഀ excavation with light equipment on tracks. Heavy equipment can bring up the moistureഀ from the underlaying soils and create a soft and unsuitable base for the foundation. Softഀ spots detected during the proof-rolling, should be removed by overexcavation. Anyഀ overexcavation within the proposed foundation, should be backfilled, in 8 inches looseഀ level lifts and compacted to 100% of the maximum dry density and within 2 percent of theഀ LKP Engineering, Inc.ഀ 6ഀ level lifts and compacted to 100% of the maximum dry density and within 2 percent of theഀ optimum moisture content as determined in a laboratory from a Standard Proctor testഀ (ASTM D-698). A structural fill, placed under footings should be tested by the engineer orഀ her representatives on regular basis. As an alternative, the structural fill can be replacedഀ with clean, crushed rock.ഀ SLAB CONSTRUCTIONഀ The natural, on-site soils, exclusive of fill, topsoil and organics, are suitable toഀ support lightly loaded slab-on-grade construction. However the high ground water levelഀ should be considered, when determining the slab on grade elevation. Based on theഀ findings from the soil and foundation investigation, a structural fill will be needed toഀ provide a minimum separation of two feet between the high ground water table and theഀ bottom of the proposed slab on grade. An underdrain system might also be necessary forഀ the slab on grade areas. The subgrade for the slab-on-grade construction should be proofഀ compacted to detect and remove soft spots. They should backfill overexcavated soft spotsഀ and other underslab fill with suitable material, compacted to a minimum of 95 percent ofഀ the maximum standard Proctor density (ASTM D-698). Suitable material should be freeഀ from topsoil, organics and rock fragments greater than 3 inches.ഀ The concrete slab should be constructed over a 24-inch layer of clean gravelഀ consisting of -3/4 inch gravel with at least 50% retained on the No. 4 sieve and less than 3ഀ percent passing the No. 200 sieve.ഀ They should reinforce the concrete slab-on-grade and score control jointsഀ according to the American Concrete Institute requirements and per the recommendationsഀ of the designer to reduce damage due to shrinkage. The concrete slab should be separatedഀ from the foundation walls and columns with expansion joints to allow for independentഀ LKP Engineering, Inc.ഀ 7ഀ movement without causing damage.ഀ RETAINING WALLSഀ They should design foundation walls retaining earth and retaining structures thatഀ are laterally supported to resist an equivalent fluid density of 60 pcf for an "at-rest"ഀ condition. Laterally unrestrained structures retaining the on-site earth should be designedഀ to resist an equivalent fluid density of 40 pcf for the "active" case.ഀ The above design recommendations assume drained backfill conditions and aഀ horizontal backfill surface. Surcharge loading due to adjacent structures, weight ofഀ temporary stored construction materials and equipment, inclined backfill and hydrostaticഀ pressure due to undrained backfill should be incorporated in the design. They should try toഀ prevent the buildup of hydrostatic pressure behind the retaining wall.ഀ UNDERDRAIN SYSTEMഀ To reduce the risk of surface water infiltrating the foundation subsoil, theഀ installation of a foundation perimeter drain is recommended. The foundation perimeterഀ drain should consist of a 4-inch diameter perforated pipe sloped to a suitable gravityഀ outlet. The drain should slope at 1/4 inch per foot if flexible or at 1/8 of an inch if rigidഀ pipe is used. The drain pipe should be covered with a minimum of 6 inches of -3/4 inchഀ free-draining granular material. Geotextile (Mirafi 140N or equivalent) should be used toഀ cover the free-draining gravel to prevent siltation and clogging of the drain. The backfillഀ above the drain should be granular material to within 2 feet of the ground surface toഀ prevent a buildup of hydrostatic pressure. The top one foot of the backfill material shouldഀ LKP Engineering, Inc.ഀ 8ഀ consist of a relatively impervious fill. The backfill should be sloping away from theഀ building. It is very likely that the recommendations for the underdrain system will beഀ modified to include ground water dewatering, once the plans are more complete, and atഀ the time of construction.ഀ SITE GRADING AND DRAINAGEഀ A grading plan was not available for our review. The following recommendationsഀ are general. The site surrounding the building structure should slope away from theഀ building in all directions. A minimum of 12 inches in the first 10 feet is recommended inഀ unpaved areas, and three inches in the first 10 feet in paved areas. The top of the granularഀ foundation backfill should be covered with a minimum of 1 foot of relatively imperviousഀ fill to reduce the potential of surface water infiltrating the foundation subsoils.ഀ Surface water naturally draining toward the proposed building site or permanentഀ cuts, should be diverted around and away from it by means of drainage swales or otherഀ approved methods. The roof drains and downspouts should extend and discharge beyondഀ the limits of the backfill. Exterior backfill should be compacted at or near the optimumഀ moisture content to at least 95% of the maximum standard Proctor density underഀ pavement, sidewalk and patio areas and to at least 90% of the maximum standard Proctorഀ density under landscaped areas. Mechanical methods of compaction should be used. Doഀ not puddle the foundation excavation.ഀ LAWN IRRIGATIONഀ It is not recommended to introduce excess water to the foundation soils byഀ installing sprinkler systems next to the building. The installation of the sprinkler headsഀ LKP Engineering, Inc.ഀ 9ഀ should insure that the spray from the heads will not fall within 10 feet of foundation walls,ഀ porches or patio slabs. Lawn irrigation must be controlled.ഀ LIMITATIONഀ This report has been prepared according to locally accepted Professionalഀ Geotechnical Engineering standards for similar methods of testing and soil conditions atഀ this time. There is no other warranty either expressed or implied.ഀ The findings and recommendations of this report are based on field exploration,ഀ laboratory testing of samples obtained at the specific locations shown on the Locationഀ Sketch, Drawing No.I and on assumptions stated in the report. Soil conditions at otherഀ locations may vary, which may not become evident until the foundation excavation isഀ completed. If soil or water conditions seem different from those described in this reportഀ we should be contacted immediately to reevaluate the recommendations of this report.ഀ This report has been prepared for the exclusive use Mr. Kyle Webb, KH Webbഀ Architects, PC, for the specific application to the proposed Dayton Addition, Lot 10,ഀ Block 2, Vail Village, 3`d Filing, 344 Beaver Dam Road, Town of Vail, Eagle County,ഀ Colorado.ഀ Sincerely,ഀ LKP ENGINEERING, INC. % (Zt*) Tഀ Luiza Petrovska, PEഀ Presidentഀ JAWP 12-LKP\05153c1y-gw.rpt.wpdഀ 29526 s,ഀ LKP Engineering, Inc.ഀ BEAVERഀ DAMഀ ROഀ a Aഀ x >vഀ rs~ u[ഀ R~IA76'ഀ r iഀ T-M77ഀ rxeഀ xഀ xഀ Boringഀ xഀ # 2ഀ aഀ ഀ xഀ rr.r ~mrr .orഀ Nm rmഀ `ഀ ~ n.sm a,ഀ ..evre.c us>ഀ rra rഀ m ami xanr siuഀ w ~ 4ഀ Boring # 1ഀ r..,iഀ LOT 9ഀ as :o* wut.:.ഀ Mഀ lഀ LOTഀ 9ഀ 1ഀ BLOCK 7ഀ \V~ഀ fഀ Tഀ VAIL VILLAGEഀ FIRST FILINGഀ 10ഀ x LOഀ 0.4724-ACRESഀ ഀ 034 ~ഀ ,ഀ im ruഀ xഀ xഀ Mഀ !Cഀ I.sഀ 11t xl • r Mഀ ~i~u [ V'4SI7ഀ ~iഀ LOT I rrഀ `"~"'rഀ s: ~~nrrഀ LOT 18ഀ rഀ NOTE- S17E PLAN PROVIDED BY OTHERSഀ LOCATION SKETCHഀ CIAI./GEOTECIiNICALഀ F'ROIECT Na:ഀ Lഀ OT 10, BLOCK 2, VAIL NLLAGE, 3rd FILINGഀ 05153ഀ LKP Engineering, In c.ഀ 344 BEAKER DAM ROADഀ SCALEഀ 'ഀ - 1 20ഀ TOWN OF VAILഀ P.0. Box 2837 Edwards, CO 81632ഀ tel (970) 926-9088 fax (970) 926-9089ഀ EAGLE COUNTY, COLORADOഀ DRAWING Na:ഀ 1ഀ DATE OBSERVED: August 10, 2005 BORING NO. 1ഀ ELEVATION:ഀ Sഀ Sഀ Yഀ Aഀ DEPTHഀ FEETഀ BLOWSഀ PER FT.ഀ Mഀ Bഀ Mഀ Pഀ DESCRIP71ON OF MATERIALഀ AND SAMPLE LOCA71ONഀ LABOARTORYഀ TEST RESUL7Sഀ REMARKSഀ 0ഀ Lഀ Lഀ Eഀ -ഀ Fill, consisting of clay, gravelഀ -ഀ and some topsoilഀ -ഀ 7/12ഀ ❑ഀ 5ഀ -ഀ 10ഀ 14112ഀ ❑ഀ Gravelly, sandy clayഀ DD= 112.2 pcfഀ MC= 15.8'ഀ Ground Waterഀ @ഀ -ഀ 30112ഀ ഀ ❑ഀ Weathered bedrockഀ 15ഀ Claystone bedrockഀ 5015ഀ ❑ഀ DD= 125.9 pcfഀ MC= 11.4%ഀ zoഀ Bottom of Boring ® 20 feetഀ LEGEND:ഀ ❑ - 2-inch O.D. California Liner Sampleഀ ■ - Split Spoonഀ 24112 - Drive sample blow count. Indicates that 24 blowsഀ of a 140-pound hammer falling 30 inches wereഀ required to drive the California or the Split Spoonഀ Sampler 12 inches.ഀ DD - Natural Dry Density (pcf)ഀ MC - Natural Moisture Contentഀ -200 - Percent Passing No. 200 Sieveഀ LL - Liquid Limitഀ Pl - Plasticity Indexഀ GW - Ground waterഀ Uഀ Uഀ Eഀ PROZCT Na: 05153ഀ LKP ENGINEERING, INC.ഀ Sഀ BSഀ RFACഀ EXPLORATION LOGഀ nGURLE Na: 1ഀ DATE OBSERVED: August 10, 2005 BORING NO. 2ഀ ELEVATION:ഀ Sഀ Sഀ Yഀ Aഀ DEPTHഀ BLOWSഀ Mഀ Mഀ DESCRIP77ON OF MATERIALഀ LABOARTORYഀ REMARKSഀ FEETഀ PER FT.ഀ Bഀ Pഀ AND SAMPLE LOCA77ONഀ TEST RESULTSഀ 0ഀ Lഀ Lഀ Eഀ -ഀ Fill, consisting of clay, gravelഀ -ഀ and some topsoilഀ -ഀ 3112ഀ ❑ഀ DD= 97.3 pcfഀ Gravelly clayഀ MC= 25.2%ഀ 5ഀ -ഀ 12112ഀ tiഀ ❑ഀ DD= 114.1 pcfഀ MC= 11.9%ഀ Ground Waterഀ - 10ഀ @ 11'ഀ -ഀ 50110ഀ ❑ഀ Reddish brown, clayey, gravellyഀ sandഀ 75ഀ -ഀ 5018ഀ ❑ഀ Claystone bedrockഀ DD= 120.8 pcfഀ MC= 15.9%ഀ 20ഀ Bottom of Boring @ 20 feetഀ LEGEND:ഀ ❑ - 2-inch O.D. California Liner Sampleഀ ■ - Split Spoonഀ 24112 - Drive sample blow count. Indicates that 24 blowsഀ of a 140-pound hammer falling 30 inches wereഀ required to drive the California or the Split Spoonഀ Sampler 12 inches.ഀ DD - Natural Dry Density (pcf)ഀ MC - Natural Moisture Contentഀ -200 - Percent Passing No. 200 Sieveഀ LL - Liquid Limitഀ Pl - Plasticity Indexഀ GW - Ground waterഀ PRQECT NQ:ഀ 05153ഀ SUBSURFACE EXPLORഀ Nഀ Tഀ LKP ENGINEERING, INC.ഀ Aഀ IOഀ LOGഀ nay Na:ഀ 2ഀ 1ഀ 0ഀ cഀ -1ഀ cഀ 0ഀ kഀ Wഀ -2ഀ -3ഀ cഀ 0ഀ -4ഀ a~ഀ iഀ 4ഀ Oഀ v -5ഀ -6ഀ 1ഀ 0ഀ cഀ yഀ cഀ 0ഀ Wxഀ -2ഀ -3ഀ cഀ 0ഀ -4ഀ 4ഀ Oഀ v -5ഀ -6ഀ 0.1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of- Gravelly, sandy clay from: Boring No. 1 ® 9 feetഀ Natural Dry Unit Weight = 112.2 pcfഀ Natural Moisture Content = 15.8 percentഀ 0.1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of Claystone from:Boring No. 1 ® 19 feetഀ Natural Dry Unit Weight = 125.9 pcfഀ Natural Moisture Content = 11.4 percent 0.5% swell ® 1.3 ksf Swell Pressureഀ PROXCT Na:ഀ KP Englneering, Inc. Swell/Consolidation Test Results RaW M: 0515'ഀ 3ഀ 1ഀ 0ഀ cഀ cഀ 0ഀ kഀ Wഀ -2ഀ -3ഀ cഀ 0ഀ y -4ഀ a~ഀ 4ഀ Oഀ U -5ഀ -6ഀ 1ഀ 0ഀ cഀ -1ഀ yഀ cഀ Oഀ kഀ Wഀ -2ഀ -.jഀ Cഀ Oഀ -4ഀ o_ഀ 0ഀ -6ഀ Iഀ Iഀ 0.1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of Gravelly clay from: Boring No. 2 ® 4 feetഀ Natural Dry Unit Weight = 97.3 pcfഀ Natural Moisture Content = 25.2 percentഀ 0.1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of- Clayey, gravelly sand from: Boring No. 2 ® 9 feetഀ Natural Dry Unit Weight = 114.1 pcfഀ Natural Moisture Content = 11.9 percentഀ PRMCT Na:ഀ 0515.'ഀ KP Engineering, Inc. Swell/Consolidation Test Results FIGURE Na: 4ഀ cഀ -1ഀ cഀ 0ഀ Wkഀ -2ഀ -3ഀ cഀ 0ഀ -4ഀ ~ഀ aഀ 4ഀ Eഀ Oഀ v -5ഀ -6ഀ iഀ 0.1 1.0 10 100ഀ APPLIED PRESSURE - ksfഀ Sample of : Shale & claystone from: Boring No. 2 ® 19 feetഀ Natural Dry Unit Weight = 120.8 pcfഀ Natural Moisture Content = 15.9 percent 0.3% swell ® 1.0 ksf swell pressureഀ PRAECT Na:ഀ 05153ഀ LKP Engineering, inc. Swell - Consolidation Test Results FIGURE Na: 5ഀ COVER BACKFILL WI7H ONE FOOT OFഀ RELATIVELY IMPERVIOUS SOILഀ SWALEഀ 12ഀ DRS INഀ 78ഀ -ഀ -ഀ 1RST10ഀ _ഀ -ഀ FEETഀ ഀ ഀ - - - - - - - - - -ഀ WATERPROOFINGഀ o • -ഀ '-M/RADRVN '6000ഀ J .ഀ ' OR 30 MIL POND :LINERഀ 10ഀ .ഀ . ►ഀ • Dഀ M~ഀ FILLഀ --Gഀ Mഀ ►ഀ ഀ /ഀ ~ഀ COMPACTED TO 90.5 OF THEഀ •ഀ Q ► Dഀ ഀ ഀ MAXIMUM DRY DENSITYഀ ,ഀ _ഀ ഀ RIL TER FABRICഀ • ~Dഀ : ABOVEഀ SEEPAGE LINEഀ ► : D ' FOO77NG COARSE GRAVEL, 314 INCH DIAM,ഀ • WTH LESS THAN 5X FTNESഀ IMPERVIOUS MOISTUREഀ BARRIER GLUED TO THE MINഀ FOUNDA 170N WALLഀ FILTER FABRIC UNDER THE DRAINഀ 4-INCH DIAMETER, RIGID, PERFORATED PIPEഀ SLOPED TO A DAYLIGHT OR TO A SUMP LOCATIONഀ AT A 114-INCH PER FOOT.ഀ CIVIL/GEOTECHNICALഀ LKP Engin a ering, In c.ഀ P.O. Box 2837 Edwards, CO 81632ഀ tsl (970) 928-9088 fox (970) 926-9089ഀ PERIMETERഀ LOT 10, BLOCK Z VAlL NILLAGE; 3rd RUNGഀ 344 BMW? DAM ROADഀ 7010N OF VAILഀ EAGLE COUNTY, COLORADOഀ ATERINGഀ PRG,WT N0.: 05153ഀ N. TS.ഀ 6ഀ HE RRO W Enterprises USA, Inc.ഀ Asbestos*Lead Paint*Mold*Hazardous Materialsഀ f30 6/fLoഀ Phone (303) 763 9639ഀ Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Website www.HERRON-En*rprises.comഀ ASBESTOS SERVICESഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duran I 40YOKVഀ Order No.: Verbal ~ഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657 T°1~/n Of Vailഀ Date of Assignment: 10/03-04/06 OFF IrCt Copyഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON" Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SUMMARY OF WORKഀ Per Client request, and under the guidelines defined, HERRON' Enterprises USA, Inc. has concluded the Environmentalഀ Consultation/Asbestos Service for friable and/or non-friable Asbestos Containing Material(s) at the aforementioned propertyഀ Our Environmental Consultation/Asbestos Service report may include a Limited Asbestos Building Inspection, descriptions ofഀ Bulk, Dust, and/or Air Monitoring samples, their locations and analyses data, which have been obtained and analysesഀ performed in accordance with local, state, and/or federal regulations.ഀ For Calculation purposes of samples obtained by HERRON', all results are expressed basis actual sampling duration, withഀ courtesy 8 hours time weighted average calculations, based on the actual sampling duration. For Calculation purposes ofഀ samples submitted to HERRON", all results are expressed basis actual sampling duration, as submitted by the Client.ഀ HERRON" implies no warranty to the accuracy of the information or the samples submitted by the Client. In order to makeഀ exact determinations, the employer should calculate exact times based on containment sign-in/out sheets for TWA's, inഀ accordance with current OSHA regulations.ഀ All Miscellaneous Provisions, Terms and Conditions apply to all services provided as indicated in HERRON" current Termsഀ of Services.ഀ Information and data which has been generated as a result of this Environmental Consultation/Asbestos Service will remainഀ confidential and will not be released to any party without prior written authorization from Client(s) (refer to authorizedഀ distribution).ഀ We appreciate the confidence which has been demonstrated by your continued patronage, and look forward to assisting youഀ and your group should you have future needs of Environmental Consultation/Asbestos Services.ഀ Sincerely,ഀ Jamie L. Herron-Johnsonഀ Supervisorഀ HERRON'Enterprises USA, Inc.ഀ Distribution:ഀ Noneഀ Page 1 of 7ഀ 46ഀ H E R RO N ® Enterprises USA, Inc. Phone (303) 763 9639ഀ Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Asbestos*Lead''P'WnVMold*Hazardous Materials Website www.HERRON-Enterprises.comഀ EnMironmentalgServic *Industrial Hygienists 7261 W. Hampden Ave., Lakewood, CO 80227-5305ഀ FIELD REPORT & OBSERVATIONSഀ Client: ;4 Colora o Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON' Project No.: 0927063ഀ Date of Report: 10/04/06ഀ DATE TIME SUMMARY OF EVENTSഀ 10/03/06 Requested to perform Final Visual Containment(s) Inspection(s), Final Clearanceഀ (MARL/OSHA) Air Monitoring for Gross and Component removal of approximately 192 SF ofഀ Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ 1300 Completed Final Visual Containment Inspection-2nd Floor Level, Full Enclosure Area appearsഀ to meet the scope of work, regulatory requirements, where visible/accessible after final detailഀ cleaningഀ 1320 Commenced (MARL/OSHA) Air Monitoringഀ 1345 Completed Final Visual Containment Inspection-1st Floor Level, Full Enclosure Area appearsഀ to meet the scope of work, regulatory requirements, where visible/accessible after final detailഀ cleaningഀ 1547 Completed (MAAL/OSHA) Air Monitoringഀ PM Completed (MARL/OSHA) Air Monitoring PCM analysis-All Work Area samples below AQCCഀ MARL, <=0.01 f/cc/OSHA 1926.1101, EL <1.0 f/cc, PEL <0.10 f/cc, where regulated, unlessഀ otherwise noted as follows: NAഀ Advised resultsഀ 10/04/06 AM Field documentation completed and report distributed (refer to distribution)ഀ Page 2 of 7ഀ 1 H E R N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lonnie. Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*lndu trial Hygienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ ASBESTOS AIR SAMPLING DATA/NIOSH 7400 FIBER COUNT ANALYSISഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SAMPLEഀ TIMEഀ FLOW RATEഀ FIBERഀ NO. ANDഀ PUMP ON OFF TOTഀ (LPM) (LPM)ഀ VOL PARTICULATE FIBER FIELD DENSITY LOD FIBERSഀ DESC.ഀ NO HR MIN HR MIN MINഀ ON OFFഀ (L) LOADING COUNT COUNT (F/MM2) (F/CC) (F/CC)ഀ 100306-1 131 13 20 15 12 112 13.50 13.50 1512 L 5.0 100 6.369 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 1 of 5ഀ 100306-2 134 13 20 15 12 112 13.50 13.50 1512 L 3.0 100 3.822 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 2 of 5ഀ 100306-3 122 13 20 15 12 112 13.50 13.50 1512 L 8.0 100 10.191 0.002 0.003ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 3 of 5ഀ 100306-4 133 13 20 15 12 112 13.50 13.50 1512 L 6.0 100 7.643 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 4 of 5ഀ 100306-5 135 13 20 15 12 112 13.50 13.50 1512 L 7.0 100 8.917 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 5 of 5ഀ 100306-6 135 13 20 15 12 112 13.50 13.50 1512 L 7.0 100 8.917 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 1 of 5ഀ 100306-7 130 14 0 15 47 107 13.50 13.50 1445 L 14.0 100 17.834 0.002 0.005ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 2 of 5ഀ Page 3 of 7ഀ 1 H E R N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Service *lndustrial H ienists 7261 W. Hampden Ave. Lakewood C 80227-5305ഀ ASBESTOS AIR SAMPLING DATA/NIOSH 7400 FIBER COUNT ANALYSISഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON" Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SAMPLE TIME FLOW RATE FIBERഀ NO. AND PUMP ON OFF TOT (LPM) (LPM) VOL PARTICULATE FIBER FIELD DENSITY LOD FIBERSഀ DESC. NO HR MIN HR MIN MIN ON OFF (L) LOADING COUNT COUNT (F/MM2) (F/CC) (F/CC)ഀ 100306-8 112 14 2 15 47 105 13.50 13.50 1418 L 12.0 100 15.287 0.002 0.004ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1 st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheettlooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 3 of 5ഀ 100306-9 156 14 4 15 47 103 13.50 13.50 1391 L 3.0 100 3.822 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 4 of 5ഀ 100306-10 142 14 5 15 47 102 13.50 13.50 1377 L 15.0 100 19.108 0.002 0.005ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 5 of 5ഀ 100306-B1 Blank VL 0.0 100ഀ 100306-B2 Blank VL 0.0 100 FPഀ Note: .8p, 25mm MCE Filter Cassettes -Note: IWA =Inside Work Area, OWA =Outside Work Area, BDL =Below Detection Limit -Note: VL = VeryLight,ഀ L = Light, M = Moderate, H = Heavy, VH = Very Heavy, CBR = Cannot Be Read - Note: Proficiency Analytical Testing (PAT) Programഀ Page 4 of 7ഀ 00 H E RRO N" PhFax 7763 9639ഀ 63 9686ഀ Enterprises USA, Inc. (303 )ഀ E-Mall Lannie.Herron@comcast.netഀ b!~shed1 Asbestos*Lead Palnt*Mold*Hazardous Materials Website www.HERRON-Enterprlses.comഀ Environmental Services*Industrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227.5305ഀ CERTIFICATION OF VISUAL INSPECTION(S)ഀ 34qഀ Buildingഀ Work Area/Contalnnientഀ Material(s)ഀ Quantity(tes)ഀ FulUMini/ഀ Regulated Areaഀ Asbestos Abatement Contractor Certificationഀ In accordance with local, state, federal regulations, and the Asbestos Abatement Summary of Work, the Asbestos Abatement Contractor herebyഀ certifies that he or she has visually inspected the Work Area (all surfaces including pipes, beams, ledges, walls, ceiling and floor, Decontaminationഀ Uni s , sheet plastic, etc. and has found no dust, debris or residue.ഀ Asbestos Abatement Contractorഀ Datefrimeഀ Certiflcation No,ഀ Printed Nameഀ Titleഀ Passഀ Fallഀ Si natureഀ Finalഀ Visualഀ AA _ഀ ,ഀ fns aഀ •°~a~aഀ 16- 3ഀ 123ഀ Ji.r , .+hc~ A -ഀ ;Edഀ e 1ഀ 0'ഀ I _ഀ ' . Air Monitoring Specialist/Asbestos Project Manager Certification 'ഀ The Air Monitoring Specialist/Asbestos Project Manager hereby certifies that he or she has accompanied the Asbestos Abatement Contractor on thisഀ visual inspection and verifies that these visual inspection(s), as indicated, have been thorough where visible/accessible, and to the best of his or herഀ Imowledge and belief, the Asbestos Abatement Contractor's Certification above as indicated and where applicable, is a true and honest one.ഀ Air Monitojrbi&Specialist/Asbestosഀ DatellYme'ഀ Certification No.ഀ Printed Nameഀ Titleഀ Passഀ . Fail.ഀ Project Managerഀ Final Visualഀ _ഀ InspecHoഀ innഀ Comments:ഀ Desi er/Pro ect Administrator Certificationഀ The Designer/Project Administrator hereby certifies that he or she has reviewed the Asbestos Abatement Contractor, Air Monitoringഀ Specialist/Asbestos Project Manager Certification on completion of this final visual inspection and believes that this final visual inspection has beenഀ thorough where visible/accessible, and to the best of his or her knowledge and belief; the Asbestos Abatement Contractor's and Air Monitoringഀ Specialist's/Asbestos Project Manager's Certification's above are true and honest ones.ഀ Designerഀ Date/Timeഀ Certification No.,ഀ Printed Nameഀ Titleഀ Si am,ഀ eഀ -ഀ Project Administratorഀ `ഀ Date/Timeഀ Certification No.ഀ Printed Nameഀ Titleഀ Siഀ atureഀ C Phone (303) 763 9639ഀ H E R ROn' 1 ~1® Enterprises USA, Inc. Fax (303) 763 9686ഀ c E-Mall LPHerron@aol.comഀ -`~bllshed1 Asbestos*Lead Based Paint*Hazardous Materials P.O. Box 620694, Littleton, Colorado 80162-0694ഀ Environmental Services*lndustrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 50227ഀ CERTIFICATION OF PRE-ABATEMENT VISUAL INSPECTION(S)ഀ Buildingഀ Work Area/Containmentഀ 1Vlaterl i1(s) QuanHty~tes) ' " Full/11tnii/ഀ Area;ഀ A~,estosbtetnelnt"ontrne. 4C.'ertaficatiiiii•ഀ 'ഀ _ഀ _ _ഀ state, , federal regulations, and the Asbestos Abatement Summary of Work, the Asbestos Abatement Contractor herebyഀ In accordance with localഀ certifies that he or she has properly prepared and has visually inspected the Work Area (all posting of permits and certifications, installation and properഀ operation or implementation of all work practices, decontamination units, waste load out areas, pre-cleaning of surfaces, manometers, disposalഀ containers, integrity of enclosures, water, surfactants, equipment, materials, protective clothing, respiratory protection, etc.) and that the Asbestosഀ Abatement Contractor is ready to proceed with active abatement.ഀ AybestoSAbatement-Contractor D~terrlnle CeettficattpnNoഀ S,'nature."ഀ rintedName Tile, y+ Pa s/Pail T:ഀ _ഀ Finalഀ ,ഀ _ഀ ഀ wഀ 'ഀ `ഀ 'ഀ ~ഀ r'1 Sഀ P 5ഀ 'ഀ i1ഀ u 1u ;1VIomഀ `ഀ tdrin S euahst/tf`sliഀ t8sഀ l?roഀ l iഀ s "ഀ , ~r„ഀ 1 fifth, itb'p _ഀ The Air Monitoring Specialist/Asbestos Project Manager hereby certifies that he or she has accompanied the Asbestos Abatement Contractor on thisഀ visual inspection and verifies that this visual inspection has been thorough where visible/accessible, and to the best of his or her knowledge and belief,ഀ the Asbestos Abatement Contractor's Certification above is a true and honest one.ഀ l)91e~1'17111. ~FTJIM, ' ~'15~~'All'Iഀ !ഀ ~ഀ I ~ r•,. iഀ Y. Eഀ 'ഀ SJഀ ~yrഀ ~Aഀ adഀ ~ഀ ~ഀ 'Lഀ .ഀ ,ഀ LLഀ ഀ ഀ tഀ ~ഀ fഀ Finalഀ C2ഀ l~Jഀ Comments:ഀ The Designer/Project Administrator hereby certifies that he or she has reviewed the Asbestos Abatement Contractor, Air Monitoringഀ Specialist/Asbestos Project Manager Certification on completion of this final visual inspection and believes that this final visual inspection has beenഀ thorough where visible/accessible, and to the best of his or her knowledge and belief, the Asbestos Abatement Contractor's and Air Monitoringഀ above are true and honest ones.ഀ Specialist s s estos Project Manager's Certification'sഀ -,mot * a ~ഀ -ഀ "Mime < ttGc-ativn i 1'~ J L 4ഀ tഀ ഀ y jഀ ru ±ഀ ~xu''n$ഀ ഀ ASഀ 'ഀ 'ഀ ~ 'ഀ rഀ S}ഀ eഀ Iഀ x,t.. Jഀ (ഀ Hഀ . dഀ F• ...J in`tz .,'~iJiഀ -ഀ 77ഀ 7777 -7Ccrhficateon [ uuP;~ഀ puAje~tAl lt$ Atorvഀ late i1 ~uicഀ $ pt ~}ts. ~ru,t k y. i s `ഀ ~ഀ ~ഀ yr~Y. i r ~ • - Y "~5,. aഀ ~i ~ tഀ 4~- .~Igl~a~nxe'~ c t, ~:~~.n t.';k~'W~tഀ (01/25/2007) John Plano - Dayton Remodel Page 1ഀ From: John Planoഀ To: millie@khwebb.comഀ Date: 01/25/2007 12:06:21 PMഀ Subject: Dayton Remodelഀ Millie,ഀ I did the original plan review for this project. I did a site visit on 1/25/07, 1 could only view the site from theഀ road, as it was taped off with warning tape and no one was on site.ഀ I have some concerns/requirements listed below.ഀ For the new floor plan change,ഀ 1) Submit a new building permit application and DRB permit application for DRB, Planning, Fireഀ department, Building Department and Public Works approval for the tear-down/rebuild.ഀ For the removal of the framing and installing shoring for the existing foundation walls.ഀ 1) If any framing is left, provide a letter from the structural engineer that it is adequate to sustain the snowഀ loads and lateral forces or his recommendations for bracing.ഀ 2) Provide an engineer stamped shoring plan for the existing foundation walls.ഀ 3) Provide a drainage and erosion control plan for the site.ഀ 4) Indicate how the exposed foundation will be protected from frost heave.ഀ 5) Provide a revised DRB permit to demo, include bond to restore the site to a natural state.ഀ 6) Apply for a demo permit, this can be concurrent with the DRB application.ഀ John Planoഀ Plan Examinerഀ Town of Vailഀ Cell, 977-6278ഀ CC: bgibson@vailgov.com; cdavis@vailgov.com; cgunion@vail.gov;ഀ mccgee@vailgov.com; mitchs@gsconco.comഀ (01/25/2007) John Plano - TOV letter 1.24.07.pdfഀ Arxrary 24, 2005ഀ Tarn of Vailഀ BII CIbem- Ramaഀ Bailing Cpartmartഀ Are Dpertrshtഀ 75 lb Ra#e Ridഀ \il, mlaado81857ഀ It Doh Fire Ibodohഀ Id 1Q Bads 2 \At MIEga31 Flirgഀ 344 BAC Dm\AI, ctlaabഀ Page 1ഀ go - EGOSഀ -ഀ DH BIIഀ arirg dmdlcn of the Do reddErm n efiah, the stutire resorted more dhd nA 'ഀ taxies in keying the edsting structre V1b arseഀ au re going in to the rehaefion that the edoia Hells me all 2xt m l&Ldm and the floors woe franad Hith 200 and 1 Aഀ hmm * in std of plywood. VVhat He we rut awe of Res the poor soils used as back fill along the south of the propaiy. %ഀ had a m-&u cbm rrAng Wth BII CIMII and Mich 3hrde Hith Gage 3aaAr (bhdru cbm Q M)eny, Um Rkadca Wth 1-19ഀ ErxjnEffing 'uEr Plc in Wth 3rucUral tad (d, di Q and Ted bthnsm .ith Eduerds r-H I kV 'd that soiufixh wallഀ gi ng. sat ateഀ be b rarne the fill and rglaoad it Wth &Ldral fill for s ppating the rhea bundation, the second option is b use hdical pers. If TCഀ we t83i hdical piers we world not be able b propaly Hrsfcproof the a4sting fou>d cn which arreitly has rroistire oaring thraghഀ the am txrhdation Hell. The emabr slid that he mold not Ivethe mouth side ad dg b the edsting tooting daetion due to the 6S Colഀ proamity of the rear propaty line and the utility masarerht lie final mnduEion fran the rrAng was to disam v& the mwഀ renxing the edsfirg house and more the bogorint b the north 3. Vb would lewe the edsling soulh tarxiatim Hell and use it as aഀ shoring well. Ttis Hold allay us b par ar rev footings and propalyHelirproof the farxta m veil that beck-fill bd&w the revഀ and edsling bundatim Hells with ga\d.ഀ % are arrehtly naing bnwad A the approW fooghrint The dint node it \ay dear that he doe; not went to rededgn theഀ entire house W he would like us b fix morns of the aess m we Raking arand as a rerrodd such as the 24 walls; the arumഀ wells on the Iona lad, lancing the attire hose so the driv ay is not as sit, Et V1b are not emadng hdght lints orഀ m3dnang A but the south west corns of the edsting hale is in@ side;etbac. If we use the awing bopxint and more theഀ horse b the north 3 fEEt m Hill still be in the sidesdtladc, but He are not changing folk or mass V )b are reducing the mass in theഀ side stack by &enging the roof from the edsting gable b a flat roof.ഀ As this red®gh will take m-nefine to renork, the prge3 is arreitly on hold. The client doe; riot vat the suet 43le of the haleഀ to be an eyesore in the reftorhood and the otaclor dons nut Rent it to be an unsafe structure The struckral Onffഀ reran xW snoring all tarring and using sl ad spoons for the mullh farxlalim well. VVxk He be allonei to rase the fraying,ഀ sane the jab A, ad lad this spring / early srmu build the appraed bolprint that has ban m3A 3 fed to the north?ഀ Rm m vArm on the direction m should proomJ.ഀ Thank P~ഀ Mllie Aldrich, AAA A Bonഀ k.h. with achlt & paഀ 1)70.477.299( ow~w.khuwhb rnmഀ 3~g_atg5ഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ ADD/ALT SFR BUILD PERMIT Permit B06-0321ഀ Project # PRJ06-0162ഀ Job Address: 344 BEAVER DAM RD VAIL Status ISSUEDഀ Location.....: 344 BEAVER DAM RD Applied 10/17/2006ഀ Parcel No...: 210107113012 Issued 11/16/2006ഀ Expires 05/15/2007ഀ OWNERഀ DAYTON, JOHN W.ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANTഀ GEORGE SHAEFFERഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ CONTRACTORഀ GEORGE SHAEFFERഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ ARCHITECTഀ K.H. WEBB ARCHI'ഀ 710 WEST LIOJഀ VAILഀ CO 81657ഀ License: C00000:ഀ Description:ഀ REMODEL/ADDITION TO SFRഀ Occupancy: R-3ഀ Type Construction: VBഀ & ARLENE J. 10/17/2006ഀ CONSTRUCTION10/17/2006 Phone: 845-5656ഀ CONSTRUCTION10/17/ dr neഀ ECTS 0/ 2006 honeഀ AD CI UNIഀ 56ഀ -477-2990ഀ Valuation: 1,500,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 2100ഀ *****************+****************************a~***************** FEE SUMMARYഀ Building > $7,433.75 Restuarant Plan Review--> $0.00 Total Calculated Fees--> $12,583.69ഀ Plan Check > $4,831.94 Recreation Fee--------------> $315.00 Additional Fees > $0.00ഀ Investigation—> $0.00 TOTAL FEES--------------> $12,583.69 Total Permit Fee--------> $12,583.69ഀ Will Call > $3.00 Payments-----------------> $12,583.69ഀ BALANCE DUE------- > $0.00ഀ Approvals:ഀ Item: 05100 BUILDING DEPARTMENTഀ 11/02/2006 jplano Action: DN correctionsഀ requiredഀ F:\cdev\CHRIS\PERMIT.COMMENTS\B06-0321\B06-0321.DOCഀ 11/16/2006 jplano Action: AP correctionsഀ receivedഀ Item: 05400 PLANNING DEPARTMENTഀ 10/23/2006 bgibson Action: APഀ Item: 05600 FIRE DEPARTMENTഀ 11/01/2006 JJRഀ alarm system requiredഀ licensed by TOV.ഀ Fire sprinkler systemഀ Item: 05500 PUBLIC WORKSഀ 10/26/2006 gcഀ Action: AP Monitored fireഀ Submit shop drawings by contractorഀ recommended.ഀ Action: DNഀ 11/16/2006 CSALLI Action: AP PUBLIC WAY PERMITഀ REQUIREDഀ See the Conditions section of this Document for any that may apply.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plotഀ plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to complyഀ with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, designഀ review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00ഀ AM - 4 PM.ഀ ATURE)9F-'DWNER OR CONTRACTOR FOR HIMSELF AND OWNERഀ CONDITIONS OF APPROVALഀ Permit B06-0321 as of 11-16-2006 Status: ISSUEDഀ Permit Type: ADD/ALT SFR BUILD PERMIT Applied: 10/17/2006ഀ Applicant: GEORGE SHAEFFER CONSTRUCTION Issued: 11/16/2006ഀ 845-5656 To Expire: 05/15/2007ഀ Job Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Parcel No: 210107113012ഀ Description:ഀ REMODEL/ADDITION TO SFRഀ Conditions x**~ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODEഀ COMPLIANCE.ഀ Cond: CON0008539ഀ Monitored fire alarm required and shall comply with NFPAഀ 72(2002) and VFES standards.ഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R060001735 Amount: $4,831.94 10/17/200601:43 PMഀ Payment Method: Check Init: JSഀ Notation: 86619/GEORGEഀ SHAEFFER CONST COഀ ഀ Permit No: B06-0321 Type: ADD/ALT SFR BUILD PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ .Location: 344 BEAVER DAM RDഀ Total Fees: $12,268.69ഀ This Payment: $4,831.94 Total ALL Pmts: $4,831.94ഀ Balance: $7,436.75ഀ k;k;k**#kk;kk##;kk**##**#**;k*;k**;tkk*#k***#><###~>::k#~#~#~k#**x*k*#;k####*****k#$;k;k#;k***#k;k#####k*k;kഀ ACCOUNTITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ PF 00100003112300 PLAN CHECK FEES 4,831.94ഀ TOWN OF VAIL, COLORADOCopy Reprinted on 09-11-2007 at 16:30:20 09/11/2007ഀ Statementഀ Statement Number: R060001998 Amount: $7,751.75 11/16/200604:39 PMഀ Payment Method: Check Init: DDGഀ Notation: Georgeഀ Shaeffer 87059ഀ ഀ Permit No: B06-0321 Type: ADD/ALT SFR BUILD PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $12,583.69ഀ This Payment: $7,751.75 Total ALL Pmts: $12,583.69ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ BP 00100003111100 BUILDING PERMIT FEES 7,433.75ഀ RF 11100003112700 RECREATION FEES 315.00ഀ WC 00100003112800 WILL CALL INSPECTION FEE 3.00ഀ r qjcj~6~ഀ * (9 , z Lp'~ഀ 0ഀ gഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR?UNLNഀ its(ഀ Projectഀ s O Building Permitഀ 970-479-2149 (inspectionഀ MOOFV& TOWN OF VAIL BUILDING PERMIT APPLICATIONഀ Separate Permits are required for electrical, plumbing, mechanical, etc.!ഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ CONTRACTOR INFORMATIONഀ General Contractor: Town of V it Re No.: JIഀ Contact Person and Phone Xs:ഀ GEORGE SHAEFFER CONSTRUC ION - Mitch Sturde 970-390-5605ഀ Email address: mitchs@qsconco.com Fax 970-84507013ഀ Contractor Signature:ഀ COMPLETE VAI HAT1ONR FOR Rl1II r)INr. PFRMIT 11 nhnr X Mnforiniaഀ BUILDING: $ 1,500, 000.ഀ ELECTRICAL: $ഀ OTHER: $ഀ PLUMBING: $ഀ MECHANICAL: $ഀ TOTAL: $ഀ For Parcel # ContactEaale CouafvAssessois Ofifice at 970-32X-B8JII nr vicif r vww Pan/P-~n1,,nfv rnmഀ Parcel # 21 01 0 7113012ഀ Job Name: Dayton Residenceഀ Job Address: 344 BEaver Dam Rd.ഀ I Legal Description Lot: 1 jjl Block: 2 Filing: 3rd Subdivision:ഀ Owners Name: John Dayton Address2703 Routh St Dallas PXഀ Phone:ഀ Architect/Designer: Address:ഀ Phone:ഀ 970-479-2990ഀ Engineer:ഀ 13 Solu ionress: PO Box 2494 Avon CO 81 6ഀ Ohon70-949-7100ഀ Detailed description of wor :ഀ Work Class: New( ) Addition( ) Remodel (X) Repair ( ) Demo ( ) Other ( )ഀ Work Type: Interior ( ) Exterior ( ) Both i X Does an EHU exist at this location: Yes( ) No (X)ഀ Type of Bldg.: Single-family (X) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )ഀ No. of Existing Dwelling Units in this building: n /a No. of Accommodation Units in this building: n /aഀ No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning Xഀ No/Type of Fireplaces Proposed: Gas Appliances Gas Los Wood/Pellet Wood Burning NOT ALLOWEDഀ Does a Fire Alarm Exist: Yes( ) No k ) 11 Does a Fire Sprinkler System Exist: Yes( ) No( 3ഀ *****************************************FOR OFFICE USE ONLY***********************************************ഀ Type of Construction: vഀ Occupancy Group: Accepted By:ഀ F:\cdev\FORMS\Permits\Building\building_permit_4-21-06.DOC Page 1 of 16 04/21/2006ഀ PI328Lഀ PAGE: 1ഀ F P O Eഀ N T R Yഀ /ഀ R E C E I V I N G R E P O R Tഀ ഀ FPO NUMBERഀ ഀ F30610ഀ ഀ ഀ DATE RECEIVED: 9/11/07ഀ REMARKSഀ PARTIAL REFUND ON VOIDED BUILDING PERMITഀ RECEIVED BY: LCഀ ENTERED: 9/11/07 16:41 BY: LCAMPBELLഀ VENDOR: 000000ഀ 1 - GEORGEഀ SHAEFFER CONSTRUCTIONഀ INVOICE NUMBER:ഀ B06-0321ഀ INVOICE DATE: 9/11/07ഀ INVOICE POSTED:ഀ 9/11/07ഀ 16:41 BY: LCAMPBELLഀ PAYMENT DUE:ഀ 9/21/07ഀ AMOUNT: $ 6265.00ഀ ACCOUNT#ഀ ഀ PROJ#ഀ AMOUNT ITEM DESCRIPTIONഀ 00100003111100ഀ ഀ ഀ $ഀ ഀ 5947.00 80% OF BLDG PERMIT FEEഀ 11100003112700ഀ $ഀ 315.00 1000 REC FEEഀ 00100003112800ഀ $ഀ 3.00 1000 WILL CALL FEEഀ TOWN OF Vidഀ Department of Community Developmentഀ Building Safety and Inspection Servicesഀ 75 South Frontage Roadഀ Vail, Colorado 81657ഀ 970-479-2138ഀ FAX 970-479-2452ഀ www. vailgovcomഀ BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS:ഀ TO: Contractor/Applicantഀ George Shafferഀ Architectഀ Webbഀ FAX/Email (970)845-7013ഀ NUMBER OF PAGES:ഀ FROM:ഀ DATE:ഀ BUILDING PERMITഀ OWNERS NAME:ഀ SITE ADDRESS:ഀ OCCUPANCY GROUP:ഀ TYPE OF CONSTRUCTION:ഀ NUMBER OF STORIES:ഀ BUILDING AREA:ഀ (970)477-2965ഀ 3ഀ John Plano, Building Plans Examinerഀ 11/01/2006ഀ B06-0321ഀ Daytonഀ 344 Beaver Dam Roadഀ R-3ഀ VBഀ 2ഀ The documents submitted for this project have been reviewed for compliance with the 2003ഀ International Building Code, 2003 International Residential Code, 2003 International Mechanicalഀ Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 Internationalഀ Energy Conservation Code and 2002 National Electrical Code as modified and adopted by the Town ofഀ Vail.ഀ The following comments will need to be addressed prior to issuance of a building permit;ഀ For processing.ഀ • Please submit four complete sets of revised construction documents containing the requestedഀ information with all plan revision items clouded or otherwise identified.ഀ • Please respond in writing to each comment by marking the attached list or creating a responseഀ letter. Indicate which plan sheet, detail, specification, or calculation shows the requestedഀ information. Please send revisions to the attention of the plans examiner with the buildingഀ permit application number noted.ഀ • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, signature,ഀ registration number and date on the cover page of any structural calculations, all structuralഀ details and structural sheets of the plans. For commercial or multi-family projects all sheets ofഀ the plans must be stamped.ഀ /Building Department Comments:ഀ Y On A100 the garage drains are indicated connected to the sewer. Garage drains are not allowed to beഀ connected to public sewer. Please address accordingly.ഀ There is a mechanical room shown accessed off the new garage. This mechanical room is at a lowerഀ level than the garage floor. Elevation of ignition source of 18" above the garage floor is required. Theഀ NEC requires that outlets are to be elevated also. Indicate how this is to be maintained or provideഀ alternative assess to the area.ഀ `3! Provide a 36" landing in front of the operable leaf of door W1 from the Media Room.ഀ 4" Provide a detail for water proofing the decks that are over occupiable space or crawlspace.ഀ 'Srr Provide detail 3/500 parapet detail.ഀ Ge Change the mechanical access to the new mechanical area under the floor of bedroom #1 so it isഀ large enough to remove the equipment.ഀ The Town of Vail's amendments require fire sprinklers be installed if equipment is installed in aഀ crawlspace. Indicate on the plans that the house is sprinklered.ഀ =-8 Provide civil engineer stamped drawings for the dewatering system.ഀ L9' Indicate on the structural drawings that the dewatering drawings have been reviewed and theഀ footings maintain a minimum of two feet separation from ground water as required by theഀ geotechnical engineer. Otherwise design the foundation utilizing strait shaft piers as stated in theഀ soils report.ഀ 4k0 The slab areas are indicating 4" of gravel beneath. The soils report is recommending two feet ofഀ gravel under slabs and connecting the gravel to the perimeter drain. Indicate the geotechnicalഀ engineer's recommendations on the structural drawings.ഀ - V !1 Have the civil engineer make a recommendation if an under slab drainage system is required, per theഀ soils report.ഀ v41 Show on the plans how the crawlspaces are to be ventilated.ഀ 1--?3 Provide the installation instructions for the new boiler to verify it can be installed in a 5'tall space.ഀ Indicate on the structural drawings the minimum thickness of the glass for the glazing in the floor.ഀ Verify and indicate that it meets the design criteria indicated in IBC 2409.ഀ Public Work's Department Comments:ഀ 15 Call out height of retaining wall 3/S6. Town of Vail requirements require 6' or less.ഀ 16 Detail on the bar grate to show how it is supported.ഀ 17 The architectural drawings need to match the Civil Engineer's drawings.ഀ 18 Remove the light out of the right of way.ഀ 19 Call out 4' pan, 2" invert and no heat in pan.ഀ 20 Separate zone of heat in the right of way.ഀ 21 Slope 2:1 in back of site.ഀ Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance ofഀ a permit, please check all requested information is included with the resubmitted plans. Please submitഀ revised plans as a complete set. Partial plan resubmittals will not be reviewed.ഀ John Planoഀ I.C.C. Plans Examinerഀ Town of Vail Building Safety and Inspection Servicesഀ 970.479.2140ഀ jplano@vailgov.comഀ George Calbergഀ Public Works Construction Inspectorഀ 970.479.2166ഀ gcalberg@vailgov.comഀ F:\cdev\CHRIS\PERMIT.COMMENTS\B06-0321\B06-0321 DOCഀ P. 1ഀ COMMUNICATION RESULT REPORT ( NOV. 2.2006 4:57PM ) * ~ ~ഀ TTIഀ FILE MODE OPTION ADDRESS (GROUP) RESULT PAGEഀ ഀ 561 MEMORY TX 98457013 OK P. 3:'3ഀ REASON FOR ERRORഀ E-1) HANG UP OR LINE FAILഀ E-3) NO ANSWERഀ E-2) BUSYഀ E-4) NO FACSIMILE CONNECTIONഀ NfffPA~LB:~'ഀ Department ofCommunity LL-velopmentഀ Building Safety and rnsp&-bon Servicesഀ 75 South Frontage Roadഀ Bail, Colorado 81657ഀ 970-979-2138ഀ FAX 97079-2452ഀ www. vailgov, comഀ BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS:ഀ TO: Contractor/Applicantഀ George Shafferഀ Architഀ Webbഀ FAX/Email (970)8457013ഀ NUMBER OF PACES:ഀ FROM:ഀ DATE:ഀ BUILDING PERMITഀ OWNERS NAME;ഀ SITE ADDRESS:ഀ OCCUPANCY Ir.Rn::o!ഀ (970)477-2965ഀ 3ഀ John Plano, Building Plans Examinerഀ 11/01./2006ഀ B06-0321ഀ Daytonഀ 344 Beaver Dam Roadഀ 0-1ഀ November 10, 2006ഀ cഀ Wഀ Town of Vailഀ Attn: John Plano - Examinerഀ 75 South frontage Roadഀ Vail, Colorado 81657ഀ Re: Dayton Residenceഀ 344 Beaver Dam Roadഀ Vail COഀ B06-0321ഀ Dear John -ഀ Please review the attached four sets of drawings and accompanying letters from UP Engineering, inc. and SDS, inc. in response to your plan comments.ഀ Building Department Comments:ഀ vK, Garage drains to daylight. See revision A100ഀ Any type of ignition source (outlets, relay, etc) must be 18" above garage floor. See revision A100ഀ Changed operable leaf of door WI to provide a 36" landing. See revision A101ഀ i~ See detail 4 on A500 - waterproof decks over living space.ഀ vY See detail 3 on A500 - parapet detailഀ %b: No mechanical under bedroom #1 crawl space. See revision A100ഀ V No mechanical under bedroom #1 crawl space. See revision A100ഀ See letter from UP engineeringഀ See letter from LKP engineering and SDS engineeringഀ 6fr See letter from SDS engineering, and revision S2ഀ 'qf.. See letter from UP engineeringഀ See revision A100ഀ ~,,13. No mechanical under bedroom #1 crawl space. See revision A100, boiler is located in mechanical room #118 See revision A101ഀ See letter from SDS engineering, and revision S4ഀ Public Work's Department Comments:ഀ 1e See letter from SDS engineering, and revision 3/S6ഀ '16. No bar grate on drive, see revision A001ഀ ,a.--'see revision A001ഀ `(O' Relocated landscape light out of the right of way, see revision A003ഀ See letter from UP engineeringഀ See revision A001ഀ ~~1. See letter from UP engineeringഀ Please call if you have any questions.ഀ Thank you,ഀ tഀ Millie Aldrich, AIA Assoc.ഀ k.h. webb architects pc.ഀ vഀ 953 SOUTH FRONTAGE ROAD WEST STE 216 VAIL COLORADO 81657ഀ 970.477.2990 970.477. 2965( F) www.khwebb.comഀ A9FM8ER OF THE AMERICAN INSTITUTE OF ARCHITECTSഀ 9ഀ 1 ng neering, Inaഀ CMI-t.1.rM Et.'.HNI Lഀ November 7,, 22006ഀ -IS. Millie Aldrichഀ K.H. Webb Ar-hitcct4ഀ 710 W Lionshe-ad Circleഀ 'Fail, C 81657ഀ T ear ill.icഀ RE; TOV Building PerInill +COMMIC ,tsഀ Dayton 'Ressiden-reഀ Lot 10. Block Z, Vail ''Yra.l[age, Filing 3ഀ 744 Beaver Dom Road, Vailഀ Eagle CC)ur-A)', CQJJ+ r. oഀ Project No, 5l 53ഀ We have rev evved the comments you circled on the OV cornaxmcats:, namely eommcntഀ numbers, 8, 9, 11. 19 and 1_ p"&Hom iag is our reply-.ഀ +C' .,mnicn1s. - We have rot prcpar l dra Mugs for a dew term systc7xt at this time. uTഀ into.%T can : tct prepare ale at.riq draw i.n ;s, if it is found n.ccmn-, ai~er ~~c have observedഀ theഀ so l and rr,~t~nd uver conditions within the xcavation for die rop,~se cl r ttiodcl'add.itioiഀ Cumnicm 4 - Due to the Iit iced cccss to the site dining our original soil and fouatlationഀ invescit Ctzon, voc would not lest or ohsenr the soil and round water conditions; in areas outerഀ lien the drive-v av The recommendation of the soil's report for a convention. I q ,c of fmidationഀ with spread Rx'11ings supported on the undiitnrbed clayey-gm- velly coil ac War bedrock. beto%a, anyഀ fill or topsoiI should ti observed, undI of en hot obscrvation.ഀ Comment l 1 - Dctc.rmination for the aced of an ul d`rdiuin system Under the stab onഀ ua, Je areas witl be made at the bane of °rt hula olirscri t:ion,ഀ Comment 4,11? -The civil draWir labeled C-1, 9nd dated eptenAver '6, 2006. is Labeledഀ ,%ith .a note ca find For a 4-foot pars ti.nd the ecinc:rete fan is Cabclcd with spot el-rvaOrmi at theഀ utiddle top. of* the concrcit pats (t th sides and in alit invert.ഀ Comment 11 -The 4.toi at the hack: of t;h .site is 2A until it ants the existing grade,ഀ k0ii:li varic% from about 1-1 to about -Si I.ഀ I!' u a L ti any que-.-bons, please do nig hesitate t gall,ഀ i~ccc:ly,ഀ LKP Engineering, I'nc.ഀ rഀ Luiza PeE37k ska. PEഀ Presidentഀ One cop scanned and c-mailed to: mdli.sti:khwcl bxornഀ P.O. Box 2$: ,l , C() 8 163 2, (97 0) 26-x` ,88 Tel, (97'0'1926-9(189 Faxഀ 71utions inCഀ E N G I N E E R I N Gഀ November 9, 2006,ഀ Recordഀ Proiiect: Dayton Remodel #0107-06ഀ P. O. BOX 2494ഀ AVON.CO 81620ഀ PH970.949.7100ഀ m970.949.3377ഀ We have reviewed the plan review comments from the Town of Vail dated 11/1/06. This record addresses theഀ comments regarding the structural design, specifically items 9, 10, 14 and 15:ഀ Comment #9 -ഀ It is our understanding that a dewatering system has not been designed by the geotechnical engineer. Atഀ the time of excavation, LKP Engineering, inc. will determine if a dewatering system is necessary, and weഀ will revise the foundation design and drawings based on their recommendations.ഀ Comment #10 -ഀ We have revised the slab plan notes to refer to the recommendations of the geotechnical engineer forഀ the depth of gravel beneath the slab.ഀ Comment #14 -ഀ The fully tempered glass floor panel must be a minimum thickness of/" for the dimensions shown on theഀ architectural drawings. We have added this requirement to sheet S4.ഀ Comment #15 -ഀ The height of the site retaining walls is indicated on plan. We have revised detail 3/S6 to indicate theഀ maximum 6-0 exposed wall height.ഀ Tyler F elddchഀ Viceഀ Jeffrey P. Leonardo, Pഀ 0ഀ Aഀ TOW[ OF VKഀ ASBESTOS TESTING REQUIREMENTSഀ THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTINGഀ ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED.ഀ AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDINGഀ MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVEഀ NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT.ഀ A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ • I have included the asbestos test and report with my building permit applicationഀ f 0114(14 eഀ applicantഀ ORഀ dateഀ • I certify my project will not disturb or remove more than 160 s.f. of building material. The constructionഀ plans submitted with my application clearly indicate this information. (This will be verified during planഀ review, and will delay your project if found to be inaccurate)ഀ applicant signatureഀ ORഀ dateഀ • The building was constructed after October 12, 1988. The date of construction wasഀ applicant signatureഀ dateഀ original construction dateഀ F:\cdev\FORMS\Permits\Building\building_permit_4-21-06.DOC Page 4 of 16 04/21/2006ഀ H E R R O N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*lndustrial H ienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ ASBESTOS SERVICESഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SUMMARY OF WORKഀ Per Client request, and under the guidelines defined, HERRON® Enterprises USA, Inc. has concluded the Environmentalഀ Consultation/Asbestos Service for friable and/or non-friable Asbestos Containing Material(s) at the aforementioned property.ഀ Our Environmental Consultation/Asbestos Service report may include a Limited Asbestos Building Inspection, descriptions ofഀ Bulk, Dust, and/or Air Monitoring samples, their locations and analyses data, which have been obtained and analysesഀ performed in accordance with local, state, and/or federal regulations.ഀ For Calculation purposes of samples obtained by HERRON®, all results are expressed basis actual sampling duration, withഀ courtesy 8 hours time weighted average calculations, based on the actual sampling duration. For Calculation purposes ofഀ samples submitted to HERRON®, all results are expressed basis actual sampling duration, as submitted by the Client.ഀ HERRON® implies no warranty to the accuracy of the information or the samples submitted by the Client. In order to makeഀ exact determinations, the employer should calculate exact times based on containment sign-in/out sheets for TWA's, inഀ accordance with current OSHA regulations.ഀ All Miscellaneous Provisions, Terms and Conditions apply to all services provided as indicated in HERRON® current Termsഀ of Services.ഀ Information and data which has been generated as a result of this Environmental Consultation/Asbestos Service will remainഀ confidential and will not be released to any party without prior written authorization from Client(s) (refer to authorizedഀ distribution).ഀ We appreciate the confidence which has been demonstrated by your continued patronage, and look forward to assisting youഀ and your group should you have future needs of Environmental Consultation/Asbestos Services.ഀ Sincerely,ഀ CT`K*ഀ Jamie L. Herron-Johnsonഀ Supervisorഀ HERRON" Enterprises USA, Inc.ഀ Distribution:ഀ Noneഀ Page 1 of 7ഀ H E R R O N Phone (303) 763 9639ഀ -Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*lndustrial Hygienists 7261 W. Hampden Ave., Lakewood, CO 80227-5305ഀ FIELD REPORT & OBSERVATIONSഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact:ഀ James Duranഀ Order No.:ഀ Verbalഀ Job Location:ഀ Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment:ഀ 10/03-04/06ഀ Assignment:ഀ Environmental Consultation/Asbestos Air Monitoringഀ HERRON" Project No.:ഀ 0927063ഀ Date of Report:ഀ 10/04/06ഀ 10/03/06 Requested to perform Final Visual Containment(s) Inspection(s), Final Clearanceഀ (MAAL/OSHA) Air Monitoring for Gross and Component removal of approximately 192 SF ofഀ Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ 1300 Completed Final Visual Containment Inspection-2nd Floor Level, Full Enclosure Area appearsഀ to meet the scope of work, regulatory requirements, where visible/accessible after final detailഀ cleaningഀ 1320 Commenced (MAAL/OSHA) Air Monitoringഀ 1345 Completed Final Visual Containment Inspection-1st Floor Level, Full Enclosure Area appearsഀ to meet the scope of work, regulatory requirements, where visible/accessible after final detailഀ cleaningഀ 1547 Completed (MAAUOSHA) Air Monitoringഀ PM Completed (MAAUOSHA) Air Monitoring PCM analysis-All Work Area samples below AQCCഀ MARL, -0.01 f/cc/OSHA 1926.1101, EL <1.0 f/cc, PEL <0.10 f/cc, where regulated, unlessഀ otherwise noted as follows: NAഀ Advised resultsഀ 10/04/06 AM Field documentation completed and report distributed (refer to distribution)ഀ Page 2 of 7ഀ H E R R O N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Fierron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services *Industrial H ienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ ASBESTOS AIR SAMPLING DATA/NIOSH 7400 FIBER COUNT ANALYSISഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SAMPLE TIME FLOW RATE FIBERഀ NO. AND PUMP ON OFF TOT (LPM) (LPM) VOL PARTICULATE FIBER FIELD DENSITY LOD FIBERSഀ DESC. NO HR MIN HR MIN MIN ON OFF (L) LOADING COUNT COUNT (F/MM2) (F/CC) (F/CC)ഀ 100306-1 131 13 20 15 12 112 13.50 13.50 1512 L 5.0 100 6.369 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 1 of 5ഀ 100306-2 134 13 20 15 12 112 13.50 13.50 1512 L 3.0 100 3.822 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 2 of 5ഀ 100306-3 122 13 20 15 12 112 13.50 13.50 1512 L 8.0 100 10.191 0.002 0.003ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 3 of 5ഀ 100306-4 133 13 20 15 12 112 13.50 13.50 1512 L 6.0 100 7.643 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 4 of 5ഀ 100306-5 135 13 20 15 12 112 13.50 13.50 1512 L 7.0 100 8.917 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 2nd Floor Level, Gross removal of approximately 63 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 5 of 5ഀ 100306-6 135 13 20 15 12 112 13.50 13.50 1512 L 7.0 100 8.917 0.002 0.002ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 1 st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 1 of 5ഀ 100306-7 130 14 0 15 47 107 13.50 13.50 1445 L 14.0 100 17.834 0.002 0.005ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MAAL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 2 of 5ഀ Page 3 of 7ഀ H E R R O N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services *Industrial Hygienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ ASBESTOS AIR SAMPLING DATA/NIOSH 7400 FIBER COUNT ANALYSISഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ SAMPLE TIME FLOW RATE FIBERഀ NO. AND PUMP ON OFF TOT (LPM) (LPM) VOL PARTICULATE FIBER FIELD DENSITY LOD FIBERSഀ DESC. NO HR MIN HR MIN MIN ON OFF (L) LOADING COUNT COUNT (F/MM2ഀ (F/CC) (F/CC)ഀ 1 UU11Ub-t$ 11Z 14 2 15 47 105 13.50 13.50 1418 L 12.0 100 15.287 0.002 0.004ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 3 of 5ഀ 100306-9 156 14 4 15 47 103 13.50 13.50 1391 L 3.0 100 3.822 0.002 BDLഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1 st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 4 of 5ഀ 100306-10 142 14 5 15 47 102 13.50 13.50 1377 L 15.0 100 19.108 0.002 0.005ഀ Final Clearance, 0 0 0 0 0 0.00 0.00ഀ (MARL) Air Monitoring, 1 st Floor Level, Component removal of approximately 129 SF of Friable ACM Sheetflooring on Wood Substrate as indicated within Full Enclosure Area(s)ഀ IWA, Sample 5 of 5ഀ 100306-B1 Blank VL 0.0 100ഀ 100306-B2 Blank VL 0.0 100 FPഀ Note: .8u, 25mm MCE Filter Cassettes -Note: IWA = Inside Work Area, OWA =Outside Work Area, BDL =Below Detection Limit -Note: VL = VeryLight,ഀ L = Light, M = Moderate, H = Heavy, VH = Very Heavy, CBR = Cannot Be Read - Note: Proficiency Analytical Testing (PAT) Programഀ Page 4 of 7ഀ H E R R O N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennie.Fierron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*lndustrial Hygienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ FLOOR PLANS/SITE PHOTOGRAPHSഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON' Project No.: 0927063ഀ Date of Report: 10/04/06ഀ Final Visual Containment Inspection, 2nd Floor Level (Pass), 10/03/06ഀ Page 5 of 7ഀ 1 H E R R O N® Enterprises USA, Inc.ഀ Asbestos*Lead Paint*Mold*Hazardous Materialsഀ Phone (303) 763 9639ഀ Fax (303) 763 9686ഀ E-Mail Lennie.Herron@comcast.netഀ Website www.HERRON-Enterprises.comഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ Final Visual Containment Inspection, 1ഀ Page 6 of 7ഀ H E R R O N Phone (303) 763 9639ഀ ®Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mail Lennio.Herron@comcast.netഀ Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*lndustrial Hygienists 7261 W. Hampden Ave. Lakewood CO 80227-5305ഀ FLOOR PLANS/SITE PHOTOGRAPHSഀ Client: Colorado Environmental Services, LTD.ഀ Client Contact: James Duranഀ Order No.: Verbalഀ Job Location: Single Family Dwelling', 344 Beaver Dam., Vail, CO 81657ഀ Date of Assignment: 10/03-04/06ഀ Assignment: Environmental Consultation/Asbestos Air Monitoringഀ HERRON® Project No.: 0927063ഀ Date of Report: 10/04/06ഀ Page 7 of 7ഀ ERRO H E N® Phone (303) 763 9639ഀ Gr" . Enterprises USA, Inc. Fax (303) 763 9686ഀ E-Mall Lennla.Henron@comcast.notഀ b/lshedl Asbestos*Lead Paint*Mold*Hazardous Materials Website www.HERRON-Enterprises.comഀ Environmental Services*Industrial Hygienists 7261 W Hampden Ave Lakewood, Colorado 80227-5305ഀ CERTIFICATION OF VISUAL INSPECTION(S)ഀ 34 t.lഀ Buildingഀ Work Area/Containmentഀ Material(s)ഀ Quantity(ies)ഀ FuWMini/ഀ Re ated Areaഀ QA Vlekഀ OA,-,4ഀ Asbestos Abatement Contractor Certificationഀ In accordance with local, state, federal regulations, and the Asbestos Abatement Summary of Work, the Asbestos Abatement Contractor herebyഀ certifies that he or she has visually inspected the Work Area (all surfaces including pipes, beams, ledges, walls, ceiling and floor, Decontaminationഀ Unit(s), sheet plastic, etc. and has found no dust, debris or residue.ഀ Asbestos Abatement Contractorഀ Date/Timeഀ Certification No.ഀ Printed Nameഀ Titleഀ Passഀ Failഀ Signatureഀ Final Visualഀ Inspectionഀ - _11P6ഀ 27ഀ 4ഀ ~Ji \ a ra f}c7 Aഀ -ഀ 0ഀ d e r d 4ഀ Air Monitoring Specialist/Asbestos Project Manager Certificationഀ The Air Monitoring Specialist/Asbestos Project Manager hereby certifies that he or she has accompanied the Asbestos Abatement Contractor on thisഀ visual inspection and verifies that these visual inspection(s), as indicated, have been thorough where visible/accessible, and to the best of his or herഀ knowledge and belief the Asbestos Abatement Contractor's Certification above, as indicated and where applicable, is a true and honest one.ഀ Air Monitoring Speciallst/Asbestotഀ Datellrimeഀ Certification No.ഀ Printed Nameഀ Titleഀ Passഀ Failഀ Project Managerഀ Si n~tur@ :ഀ Final visualഀ Inspectionഀ yഀ Comments:ഀ Des er/Pro ect Administrator Certificationഀ The Designer/Project Administrator hereby certifies that he or she has reviewed the Asbestos Abatement Contractor, Air Monitoringഀ Specialist/Asbestos Project Manager Certification on completion of this final visual inspection and believes that this final visual inspection has beenഀ thorough where visible/accessible, and to the best of his or her knowledge and belief; the Asbestos Abatement Contractor's and Air Monitoringഀ ecialist's/Asbestos Project Manager's Certification's above are true and honest ones.ഀ Designerഀ Date/11meഀ Certification No.ഀ Printed Nameഀ Titleഀ Signatureഀ Project Administratorഀ Date/1'imeഀ Certification No.ഀ Printed Nameഀ Title 'ഀ Signatureഀ Fax ((303) 763 9639ഀ H E R R O W Enterprises USA, Inc. Phoneഀ 303) 763 9686ഀ E-Mall LPHerron@aol.comഀ bgshAsbestos•Lead Based Paint"Hazardous Materials P.O. Box 620694, Littleton, Colorado 80162-0694ഀ Environmental Services1ndustrial Hygienists 7261 W. Hampden Ave., Lakewood, Colorado 80227ഀ CERTIFICATION OF PRE-ABATEMENT VISUAL INSPECTION(S)ഀ Building Work Area/Containmentഀ Mater iAl(s)ഀ Quanfity(tes) Fu1111VIrnr/ഀ RegulatedArca`ഀ 30 BeAvoL b- -I It _-4ഀ Asbestos Abateuent Contractor Ccrtfication~ഀ ~tഀ _ഀ In accordance with local, state, federal regulations, and the Asbestos Abatement Summary of Work, the Asbestos Abatement Contractor herebyഀ certifies that he or she has properly prepared and has visually inspected the Work Area (all posting of permits and certifications, installation and properഀ operation or implementation of all work practices, decontamination units, waste load out areas, pre-cleaning of surfaces, manometers, disposal iഀ containers, integrity of enclosures, water, surfactants, equipment, materials, protective clothing, respiratory protection, etc.) and that the Asbestosഀ Abatement Contractor is ready to proceed with active abatement.ഀ i Asbestos Abatement (ontraclor DatelTinre Cet tification No.ഀ - Printed Name Title, Passlhaif .ഀ ~ഀ _Signature ~ഀ 1 -ഀ Final Xഀ .ഀ ~~(,~,`Iഀ ഀ ഀ Au• Monitor•un. spec ahst/Asbestos P_ra'ect ManaicrVertification, .ഀ The Zr Monitoring Specialist/Asbestos Project Manager hereby certifies that he or she has accompanied the Asbestos Abatement Contractor on this iഀ visual inspection and verifies that this visual inspection has been thorough where visible/accessible, and to the best of his or her knowledge and belief,ഀ the Asbestos Abatement Contractor's Certification above is a true and honest one.ഀ Air.Munnlqu irt,Speeralist/Asbestas Date/1'MR, ('citdi< ihonNo =Printed Name Titic P~ss/Failഀ Pro~ecGManagc rഀ Si nature``. _ഀ Finalഀ Comments:ഀ - -ഀ ഀ -ഀ - - -ഀ -ഀ -ഀ Deli er(1'ro~ject ALnun►strator CerfACahotഀ -ഀ -ഀ _ഀ _ഀ The Designer/Project Administrator hereby certifies that he or she has reviewed the Asbestos Abatement Contractor, Air Monitoringഀ Specialist/Asbestos Project Manager Certification on completion of this final visual inspection and believes that this final visual inspection has beenഀ thorough where visible/accessible, and to the best of his or her knowledge and belief, the Asbestos Abatement Contractor's and Air Monitoringഀ S ecialist s/Asbestos Project Managers Certification's above are true and honest onesഀ -ഀ - 1'it[eഀ 1~e5~gvei Datefliuie C -frcatron Prnnterl Name: ~7ഀ PxojectAdr iimstratoc Date/Time C errificatron No. Yririted Nar/ne 1 Titleഀ „ _ഀ Si akoie'ഀ TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2135ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ ALARM PERMITഀ Permit A08-0049ഀ Job Address: 344 BEAVER DAM RD VAIL Status ISSUEDഀ Location.....: Applied..: 06/11/2008ഀ Parcel No...: 210107113012 Issued . 07/09/2008ഀ Project No Expires. 01/05/2009ഀ OWNER DAYTON, JOHN W. & ARLENE J. 06/11/2008ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT THUL ELECTRONIC SYSTEMSഀ P 0 BOX 534ഀ AVONഀ CO 81620ഀ License: 112-Sഀ CONTRACTOR THUL ELECTRONIC SYSTEMSഀ P 0 BOX 534ഀ AVONഀ CO 81620ഀ License: 112-Sഀ Desciption: NEW FIRE ALARM SYSTEMഀ Valuation: $1,800.00ഀ 06/11/2008 Phone: 970-949-4638ഀ 06/11/2008 Phone: 970-949-4638ഀ FEEഀ SUMMARYഀ Electrical >ഀ $0.00ഀ Total Calculated Fees-->ഀ $299.50ഀ DRB Fee--------- >ഀ $0.00ഀ Additional Fees >ഀ $ o . 0 0ഀ Investigation >ഀ $0.00ഀ Total Permit Fee-------->ഀ $299.50ഀ Will Call >ഀ $0.00ഀ Payments >ഀ $299.50ഀ TOTAL FEES-->ഀ $299.50ഀ BALANCE DUE-------->ഀ $0.00ഀ Approvals:ഀ Item: 05600 FIRE DEPARTMENTഀ 06/13/2008 JJRഀ Action: APഀ ഀ ഀ CONDITIONS OF APPROVALഀ ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply th the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according t t towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other or In ces pf the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN JOYANC/C B/Y TELEPHONE AT 970-479-2252 FROM 8:00 AM - 5 PM.ഀ TURE OFഀ OR CONTRACTOR FOR HIMSELF AND OWNERഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R080001116 Amount: $299.50 07/09/200801:50 PMഀ Payment Method: Check Init: DDGഀ Notation: Thulഀ Electronics 17127ഀ ഀ Permit No: A08-0049 Type: ALARM PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location:ഀ Total Fees: $299.50ഀ This Payment: $299.50 Total ALL Pmts: $299.50ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ BP 00100003111100 FIRE ALARM PERMIT FEES 67.50ഀ PF 00100003112300 PLAN CHECK FEES 232.00ഀ ഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNEDഀ Project 'FR Wq _0231ഀ Building Permitഀ Alarm Permit A0$ -00 411ഀ 970-479-2135 (Inspectionsഀ lഀ TOWN'Opy~ TOWN OF VAIL FIRE ALARM PERMIT APPLICATIONഀ Commercial & Residential Fire Alarm shop drawings are required at time of 75 S.ഀ Frontage Rd. application submittal and must include information listed on the Vail, Coloradoഀ 81657 2nd page of this form. Application will not be accepted without thisഀ information.ഀ CONTRACTOR INFORMATIONഀ Fire Alarm Contractor: Town of Vail Reg. No.: I Contact and Phone Xs: ~ Iഀ - 5 1'Vl i K~ i d1 ~,t L -ഀ Lr~ rRo N IC 5 1~ഀ E-Mail Address: J -j-Q ~tti t`Yl~.t L o }ഀ Contractor Signature: sഀ IDIEVAPTAഀ COMPLETE VALUATIONS FOR ALARM PERMIT (LabrW81ഀ p ~yഀ .N fC , /1P A1~ rLഀ ` .ഀ Fire Alarrn: $ഀ e~ LTo"_ഀ Date: E 3ഀ Cnnfact Eanle Cnunty dsspssnrs Cff ce at 970-328-8940 nr visit www-Paa1P-cnunty-cnm for Parcel #ഀ Parcel # o j o 3 0~ഀ Job Name: Iഀ L:344 oAddress: E 2 bA-A P-b . VAfLAഀ Legal Description Lot: D Block: Filing: 3 Subdivision: V((I Vd((f92 11ഀ O ers Nameഀ ,4 - bA Ton!ഀ dregs:ഀ c ~o► '5Tഀ E meer:ഀ Si~~a rv€ഀ dre s: Ph nഀ o. a I b~l rsto G~.ga ~~b- ~fof - 9e8 a-ഀ Detailed Location of work: (i.e., floor, unit bldg.ഀ ~1 ~ 1l: ~ GU~ Yl ~ 4lഀ Detailed description] of work: nഀ Work Class: New Addition ( ) Remodel( ) Repair ( ) Retro-fit ( ) Other ( )ഀ )ഀ Type of Bldg.: Single-family Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant( ) Other(ഀ No. of Existing Dwelling Units in this building: i No_ of Accommodation units in this building:ഀ Does a Fire Alarm Exist: Yes ( ) No ) Does a Fire Sprinkler System Exist: Yes ( ) Noഀ ******************~r******x*******FOR OFFICE USE ONLY*************************************ഀ Other Fees:ഀ Date Received:ഀ Public Way Permit Fee:ഀ Accepted B :ഀ M F9ഀ Occupancy Group:ഀ \\Vail\datakedev\FORMS\PERMITS\ALRMPERM.DOCഀ [E11Vഀ JUN 09 2008ഀ 07/24/2002ഀ TOWN OF VAILഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ ASBESTOSഀ Job Address:ഀ Location.......:ഀ Parcel No....:ഀ Legal Description:ഀ Project No . :ഀ 344 BEAVER DAM RD VAILഀ 344 BEAVER DAM RDഀ 210107113012ഀ f "0 iQ U i ~_c -L-ഀ OWNER DAYTON, JOHN W. & ARLENE J. 09/22/2006ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT COLORADO ENVIRONMENTAL SERVI09/22/2006ഀ 2331 W.HAMPDEN AVE-SUITE 137ഀ SHERIDANഀ CO 80110ഀ License: 160-Sഀ CONTRACTOR COLORADO ENVIRONMENTAL SERVI09/22/2006ഀ 2331 W.HAMPDEN AVE-SUITE 137ഀ SHERIDANഀ CO 80110ഀ License: 160-Sഀ Desciption:ഀ REMOVAL AND DISPOSAL OF ASBESTOSഀ Permit ASB06-0024ഀ Status .ഀ Appliedഀ Issued .ഀ Expiresഀ ISSUEDഀ 09/22/2006ഀ 09/25/2006ഀ 03/24/2007ഀ Phone: 303-789-4901ഀ Phone: 303-789-4901ഀ Occupancy:ഀ Type Construction:ഀ Type Occupancy:ഀ Valuation: $11,360.00 Add Sq Ft: 0ഀ Fireplace Information: Restricted: # of Gas Appliances: 0 # of Gas Logs: 0ഀ # of wood Pellet: 0ഀ FEE SUMMARYഀ Building > $58.00 Total Calculated Fees--> $116.00ഀ Plan Check $58.00 Additional Fees > $0.00ഀ Investigation-> $0.00 Total Permit Fee > $116.00ഀ Payments------------------- > $116.00ഀ TOTAL FEES > $116.00 BALANCE DUE--------- > $0.00ഀ Approvals:ഀ Item: 05100 BUILDING DEPARTMENTഀ Item: 05600 FIRE DEPARTMENTഀ 09/22/2006 mvaughan Action: APഀ See page 2 of this Document for any conditions that may apply to this permit.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plotഀ plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to complyഀ with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, designഀ review approved, International Building and Residentail Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE FORTY-EIGHT HOX IN ADVANCE BY TELEPHONE AT 970-4F9-2135 OR 970-479-2252ഀ ATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEFഀ PAGE 2ഀ CONDITIONS OF APPROVALഀ Permit ASB06-0024 as of 09-25-2006 Status: ISSUEDഀ Permit Type:ഀ Applicant:ഀ 09/25/2006ഀ Job Address:ഀ Location:ഀ Parcel No:ഀ ASBESTOSഀ COLORADO ENVIRONMENTAL SERVICESഀ 303-789-4901ഀ 344 BEAVER DAM RD VAILഀ 344 BEAVER DAM RDഀ 210107113012ഀ Applied: 09/22/2006ഀ Issued:ഀ To Expire: 03/24/2007ഀ Description:ഀ REMOVAL AND DISPOSAL OF ASBESTOSഀ Conditions:ഀ Cond: 38ഀ (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY.ഀ AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREEഀ FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORKഀ OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACTഀ THE VAIL FIRE DEPARTMENT AT 479-2250.ഀ Cond: 1ഀ (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANYഀ WORK CAN BE STARTED.ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODEഀ COMPLIANCE.ഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R060001528 Amount: $116.00 09/25/200610:45 AMഀ Payment Method:Credit Crd Init: LTഀ Notation: CREDIT CARDഀ TKSOO JUNG, COLORADO ENVIRONMENTAL SERVICESഀ ഀ Permit No: ASB06-0024 Type: ASBESTOSഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $116.00ഀ This Payment: $116.00 Total ALL Pmts: $116.00ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ BP 00100003111100 BUILDING PERMIT FEES 58.00ഀ PF 00100003112300 PLAN CHECK FEES 58.00ഀ APPLICATION WI N BE ACCEPTED IF INCOMPLETE OR UNSIGF ` • Cഀ Projectഀ Building Permitഀ a Asbestos Permitഀ T"'r1r Y.'11L .ഀ OW V IL ASBESTOS ABATEMENT PERMIT AP LICATIONഀ Vqect per Ordinance No. 19, Series of 1998ഀ 75 S. Frontage Rd. Permit atio'~ will not be accepted without the following:ഀ Vail, Colorado 81657 1. Copies of GeneraLAbatement Certificate and State of Colorado Certificationഀ 2. A copy of written arrangements with the facility operators for any temporary disabling of theഀ air handling systems" fire sprinkler system, and alarm systems with the names and contactഀ phone numbers of these individuals.ഀ 3. Site plan with details addressing: waste container storage location. waste load out areaഀ location. entry and exiting details of abatement area. details of entry and exiting plans for theഀ occupants of the structure in unaffected areas.ഀ CONTRACTOR -INFORMATIONഀ On Site Abatement Contractor: Town of Vail Reg. No.: Contact and Phone #'s:ഀ E-Mail Address: j9fzn f ~JS~ ~°lഀ PLETE VALUATION FOR ASBESTOS ABATEMENT PERMIT (Labor & Materials)ഀ Asbestos Abatement: $ഀ Arlo _a n,7n_790_QCAIV vich* WiAhAl 0an1P-r1711f7t`V-r.")M for Parcel #ഀ contact Eagle GOUn A55 55013 LF111&C ac 7/ V-.~w-VVTV • • - _ _ _ .ഀ Parcel # 2.p L - 13d 1 - 2,ഀ Job Name: ' Job Address:ഀ ~ ! +CYA iഀ -D,._.aഀ Legal Description Lot: Block: Filing: Subdivision:ഀ Nam dress Proje Manager: dress, Phon Z-7-7- ~ 4ഀ `1 _mp_ o I x'11 Cb -ഀ Address: i Phone•ഀ P o ect Designer:ഀ fഀ Air Monitorin S ecialist: Address: L~ Phone:ഀ Y \ഀ Detailed description of work: -Pm,per 1-C L:vraA. QLrNCX dQE~~Posz,® `r' zest t `ഀ ~ttLE~ C.r -_~5ILACV% C,GACa_V, 61,&e* k-LC;CV irc~ 1 6V se~5Vn \n Z.IGGഀ ,ഀ L Start Date: Cl l23rzc End Date: is VX3 Start Time: `1,C)C. o,.cyN 11QuitTime:J5*ഀ Amount of Asbestos: Linear Feet: Square Feet: ? 55/Gal Drums: N /Nഀ Work Class: New Addition( ) Remodel Repair ( ) Demo ( ) Other ( )ഀ )ഀ Work Type: Interior ( Exterior ( ) Both(ഀ Type of Bldg.: Sin le-famil Two-family Mu r t herഀ Does a Fire Alarm Exist: 'Yes( ) No ( Do ) No )ഀ *************************************FOILOFFICEഀ Other Fees:ഀ Public Wayഀ C:\Documents and Settings\Ryan Jung\Local Settings\Temporary Internet.Files\Q.JXZ9\asbestos-perm_12-5 05.DOC Page 1 of 2 .11, 1ഀ 12/05/2005ഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ DEMO. OF PART/ALL BLDGഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.......: 344 BEAVER DAM RDഀ Parcel No....: 210107113012ഀ OWNER DAYTON, JOHN W. & ARLENE J. 07/02/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT GEORGE SHAEFFER CONSTRUCTION07/02/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ CONTRACTOR GEORGE SHAEFFER CONSTRUCTION07/02/2007ഀ PO BOX 373ഀ VAILഀ CO 81657ഀ License: 302-Aഀ Desciption:ഀ DEMOഀ Occupancy:ഀ Type Construction:ഀ Permit # D07-0007 k ct 2,ഀ Project #ഀ Statusഀ ISSUEDഀ Applied...:ഀ 07/02/2007ഀ Issuedഀ 07/11/2007ഀ Expires.....:ഀ 01/07/2008ഀ Phone: 845-5656ഀ Phone: 845-5656ഀ Valuation:ഀ $40,500.00ഀ Revision Valuation:ഀ Total Sq Ft Added: 0ഀ ഀ FEE SUMMARYഀ ഀ Building >ഀ $552.85ഀ Restuarant Plan Review-->ഀ $0.00 Total Calculated Fees-->ഀ $915.20ഀ Plan Checkഀ $359.35ഀ Recreation Fee-------------->ഀ $0.00 Additional Fees >ഀ $0.00ഀ Investigation->ഀ $0.00ഀ TOTAL FEES >ഀ $915.20 Total Permit Fee--------- >ഀ $915.20ഀ Will Call----->ഀ $3 .0 0ഀ Payments >ഀ $915.20ഀ BALANCE DUE--------- >ഀ $0.00ഀ ഀ Approvals:ഀ Item: 05100 BUILDING DEPARTMENTഀ 07/06/2007 JRM Action: APഀ Item: 05400 PLANNING DEPARTMENTഀ 07/03/2007 bgibson Action: AP DIA received.ഀ office set routed to Joe Sutherഀ See the Conditions section of this Document for any conditions that may apply to this permit.ഀ ഀ CONDITIONS OF APPROVALഀ Permit D07-0007 as of 07-11-2007 Status: ISSUEDഀ ഀ Permit Type:ഀ DEMO. OF PART/ALL BLDG.ഀ Applied:ഀ 07/02/2007ഀ Applicant:ഀ GEORGE SHAEFFER CONSTRUCTIONഀ Issued: 07/11/2007ഀ 845-5656ഀ To Expire:ഀ 01/07/2008ഀ Job Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Parcel No: 210107113012ഀ Description:ഀ DEMOഀ ***********************************************Conditions:************************************************ഀ Cond: 38ഀ (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY.ഀ AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREEഀ FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORKഀ OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACTഀ THE VAIL FIRE DEPARTMENT AT 479-2250.ഀ Cond: 1ഀ (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANYഀ WORK CAN BE STARTED.ഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODEഀ COMPLIANCE.ഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R070001214 Amount: $915.20 07/11/200704:09 PMഀ Payment Method: Check Init: DDGഀ Notation: George Shaefferഀ 89660ഀ Permit No: D07-0007 Type: DEMO. OF PART/ALL BLDG.ഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $915.20ഀ This Payment: $915.20 Total ALL Pmts: $915.20ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ BP 00100003111100 BUILDING PERMIT FEES 552.85ഀ PF 00100003112300 PLAN CHECK FEES 359.35ഀ WC 00100003112800 WILL CALL INSPECTION FEE 3.00ഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED Pr2(~ ~Vഀ Projectഀ Building Permit:ഀ i X70-479-2149(Iruspsctiorw) ~o 06ഀ T0i~OY~ ` TOWN OF VAIL BUILDING PERMIT APPUCATION Vഀ 75 S. Frontage Rd. Separate Permits are required for electrical, plumbing, mechanical, etc.l S .10ഀ Vail, Colorado 81657ഀ CONTRACTOR INFORMATIONഀ GEORGE SHAEFFER CONSTRUC ON Mitch Sturde 970-390-5605ഀ Email address: mitchs sconco. com Fax9: 970-84507013ഀ Contractor Signature:ഀ COMPLETE VALUATIONS FOR BUILDING PERMIT Labor & Materialsഀ BUILDING: $ 4omo.oo ELECTRICAL. $ OTHER: $ഀ PLUMBING: $ MECHANICAL: $ TOTAL. $ഀ FthrAIVIcei/ fCentaciE'ail/eCetinty.elasacs~snlWfW f9711,?21 3~OerriiaH wwwar~vr6~rnrinfvirn.ഀ Parcel 21010 7113 012ഀ Job Name: Dayton Residenceഀ EbAddress: J 344 BEaver Dam Rdഀ Legal Description Lot: 10ഀ 1 etodc: =Fffing: 3rd Subdivision:ഀ Owners Name- John Da ton Address2703 Routh St Dallas TX P 'ഀ Arohiteat/Designer. Address:ഀ fഀ M e-479-2990ഀ 479-2990ഀ eഀ F~gmeer Soluഀ ons` O B9Aഀ -ഀ Z494 Avon CO 1 U 97D-949-7 QOഀ Detailed description of worFc Remove all wood framingഀ Worts Class: New Addition ( ) Remodel Repair O Demo (X) Other ( )ഀ Work Type: Interior Exterior Barth 1 Xഀ Does an EHU exist at this location: Yes ( ) No (x)ഀ Type of Mg.: Sir gie-famfly (g) Two4amily MU114arnily ( }ഀ Commercial Redaurant ( ) Other ( }ഀ No. of Existing Dwetting Units in this building: nഀ No. of Amommodation Units in this building: n /aഀ No/Type of Fireplaces Exists : Gas Appliances Gas Loഀ gs Wood/Pellet Wood Burning (X)ഀ No/T of FI aces Pro : Gas Appliances Gas Lഀ ogs Wood/Pellet Wood Bum OT ALLOWEDഀ flഀ Does a Fire Alarm Exist: Yes ( ) No jf)ഀ Does a Fire Sprinkler System Exist: Yes ( ) No (ഀ FOR OFFICE USE ONLY****ഀ Town of Vailഀ . Two of 5ars6uction• R eveഀ Occupancy Group: Acce ed By: n FFICEഀ V COPYഀ w 4zi-o6.oocഀ (ICAഀ •ഀ Page 1ഀ 4 IEഀ TOWN OF VAILഀ OKഀ TWASBESTOS TESTING REQUIREMENTSഀ THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTINGഀ ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED.ഀ AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE. SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDINGഀ MATERIALS THAT MAY CONTAIN ASBESTOS.. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVEഀ NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT.ഀ A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATIONഀ • I have included the asbestos test and report with my building permit application tഀ ~c~ vv~rഀ 6c"e- ©~P f n a o 1 bii ;2ഀ • I certify my project will not disturb or remove more than 160 s' f. of building material. The constructionഀ plans-submitted with my application clearly indicate this information. (This will be verified during planഀ review, and will delay your project if found to be inaccurate)ഀ applicant signature dateഀ ORഀ • The building was constructed after October 12, 1988. The date of construction wasഀ orww mnstnKbm dateഀ a~ dateഀ F:~~1rt DOC Page 4 of 16 02/09/2005ഀ ORഀ January 24, 2005ഀ Town of Vailഀ Bill Gibson- Plannerഀ Building Departmentഀ Fire Departmentഀ 15 South Frontage Roadഀ Vail, Colorado 81651ഀ Re: Dayton Residence Renovationഀ Lot 10, Block 2, Vail Village 3AD Filingഀ 344 Beaver Dam Vail, Coloradoഀ Dear Bill -ഀ Fj~ fCOPyഀ n1f Vailഀ x*a R Fnഀ During demolition of the Dayton residence renovation, the structure revealed more challenges in keeping the existing structure. We wereഀ aware going in to the renovation that the exterior walls were all 2x4 construction and the floors were framed with 2x10 and Iഀ homasote in stead of plywood. What we were not aware of was the poor soils used as back fill along the south of the property. Weഀ had a construction meeting with Bill O'Neill and Mitch Sturde with George Shaeffer Construction Company, luiza Petrovska with UPഀ Engineering, Tyler Aldrich with Structural Design Solutions, and Ted Johnson with Edwards Excavating. UP said that one solution wouldഀ be to remove the fill and replaced it with structural fill for supporting the new foundation, the second option is to use helical piers. Ifഀ we used helical piers, we would not be able to properly waterproof the existing foundation which currently has moisture coming throughഀ the cmu foundation wall. The excavator said that he could not shore the south side and dig to the existing footing elevation due to theഀ proximity of the rear property line and the utility easement. The final conclusion from the meeting was to discuss with the ownerഀ removing the existing house and move the footprint to the north 3'. We would leave the existing south foundation wall and use it as aഀ shoring wall. This would allow us to pour our new footings and properly waterproof the foundation wall then back-fill between the newഀ and existing foundation walls with gravel.ഀ We are currently moving forward with the approved footprint. The client made it very dear that he does not want to redesign theഀ entire house, but he would like us to fix some of the areas we were working around as a remodel such as the 2x4 walls, the curvedഀ walls on the lower level, lowering the entire house so the driveway is not as steep, etc We are not exceeding height limits orഀ maximizing grfa, but the south west corner of the existing house is in a side setback. If we use the existing footprint and move theഀ house to the north 3 feet we will still be in the side setback, but we are not changing bulk or mass. We are reducing the mass in theഀ side setback by changing the roof from the existing gable to a flat roof.ഀ As this redesign will take some time to rework, the project is currently on hold. The client does not want the current state of the houseഀ to be an eye-sore in the neighborhood and the contractor does not want it to be an unsafe structure. The structural engineerഀ 4W recommended removing all framing and using steel supports for the south foundation wall. Would we be allowed to remove the framing,ഀ secure the job site, and later this spring / early summer build the approved footprint that has been moved 3 feet to the north?ഀ Please confirm on the direction we should proceed.ഀ Thank you,ഀ Zഀ Millie Aldrich, AIA Assoc.ഀ k.h. webb architects pc.ഀ D 10ഀ JAN 24 2001ഀ TOWN OF VAILഀ 953 SOUTH FRONTAGE ROAD WEST STE 216 VAIL COLORADO 81657ഀ 970.477.2990 970.477.2965( F) www.khwehh.tomഀ Charlie Davis - Re: Dayton Remodel Page 1ഀ From: Charlie Davisഀ To: John Plano; millie@khwebb.com / a3~1ഀ Date: 01/29/2007 2:26:04 PM 0(ഀ Subject: Re: Dayton Remodelഀ John,ഀ Good job communicating the items that are required for consideration to put this project on hold.ഀ Millie,ഀ This is the way to proceed from the Town of Vail's Building Safety and Inspections Services team'sഀ perspective.ഀ Does any other information need to be communicated? Let me know and I will provide any and allഀ information requestedഀ Best Regards,ഀ Charlie Davisഀ Chief BuildingOffciialഀ Town of Vailഀ 970-479-2142ഀ cdavis@vailgov.comഀ John Plano 01/25/07 3:14 PMഀ Millie,ഀ I did the original plan review for this project. I did a site visit on 1/25/07, 1 could only view the site from theഀ road, as it was taped off with warning tape and no one was on site.ഀ I have some concerns/requirements listed below.ഀ For the new floor plan change,ഀ 1) Submit a new building permit application and DRB permit application for DRB, Planning, Fireഀ department, Building Department and Public Works approval for the tear-down/rebuild.ഀ For the removal of the framing and installing shoring for the existing foundation walls.ഀ 1) If any framing is left, provide a letter from the structural engineer that it is adequate to sustain the snowഀ loads and lateral forces or his recommendations for bracing.ഀ 2) Provide an engineer stamped shoring plan for the existing foundation walls.ഀ 3) Provide a drainage and erosion control plan for the site.ഀ 4) Indicate how the exposed foundation will be protected from frost heave.ഀ 5) Provide a revised DRB permit to demo, include bond to restore the site to a natural state.ഀ 6) Apply for a demo permit, this can be concurrent with the DRB application.ഀ John Planoഀ Plan Examinerഀ Town of Vailഀ Cell, 977-6278ഀ CC: Bill Gibson; cgunion@vail.gov; mccgee@vailgov.com; mitchs@gsconco.comഀ FROM :SHAW ELECTRIC FAX NO. :9709263358ഀ 814A A/' ELECTRIC, INC.ഀ PO. 80X 1451 AVON, CO 81620ഀ 970-926-3358 6,-Co r-z~-ഀ PH.ഀ iഀ a~fഀ V""ഀ iഀ /foഀ X07 a~ഀ c-ഀ r~r ~utl~~ഀ ~t~e~~~rc~►~ andഀ 6 Lt)ഀ 1 vr, c.~d s ~.rvUtഀ ou"' SPA`'ഀ ~/U 2 tom'~ tax,ഀ cc rokഀ zALk.ഀ been c'e s sal ~ m . -Col (erഀ M,,.~. ~aഀ ~\Ce Pte- Jഀ ari(Lഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ ELECTRICAL PERMITഀ & ARLENE J. 11/14/2006ഀ o(o -0-~> 4ഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ \Ca 2-ഀ Project No : -)60G - C)ഀ OWNER DAYTON, JOHN W.ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT SHAW ELECTRICഀ P O BOX 1451ഀ AVON COഀ CO 81620ഀ License: 106-Eഀ CONTRACTOR SHAW ELECTRICഀ P O BOX 1451ഀ AVON COഀ CO 81620ഀ License: 106-Eഀ Permit E06-0245ഀ Statusഀ ISSUEDഀ Appliedഀ 11/14/2006ഀ Issued .ഀ 11/16/2006ഀ Expires .ഀ 05/15/2007ഀ 11/14/2006 Phone: 970-926-3358ഀ 11/14/2006 Phone: 970-926-3358ഀ Desciption: TEMPORARY POWER FOR A REMODEL/ADDITION TO SFRഀ Valuation: $1,200.00 Square feet: 50ഀ FEE SUMMARYഀ Electrical >ഀ $51.75ഀ Total Calculated Fees-->ഀ $54.75ഀ DRB Fee >ഀ $0.00ഀ Additional Fees >ഀ $0.00ഀ Investigation >ഀ $0.00ഀ Total Permit Fee-------->ഀ $54.75ഀ Will Call >ഀ $3.00ഀ Payments >ഀ $54.75ഀ TOTAL FEES-->ഀ $54.75ഀ BALANCE DUE-------->ഀ $0.00ഀ Approvals:ഀ Item: 06000 ELECTRICALഀ DEPARTMENTഀ 11/14/2006 shahnഀ Action: APഀ Item: 05600 FIRE DEPARTMENTഀ CONDITIONS OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plotഀ plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to complyഀ with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, designഀ review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAI~E BY TELEPHONE AT-479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4ഀ PM. / ` lഀ ATURE OF 1OWNER OR CONTRACTOR FOR HIMSELF AND OWNEFഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R060001993 Amount: $54.75 11/16/200602:24 PMഀ Payment Method: Check Init: DDGഀ Notation: Shaw 14600ഀ ഀ Permit No: E06-0245 Type: ELECTRICAL PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $54.75ഀ This Payment: $54.75 Total ALL Pmts: $54.75ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ EP 00100003111100 ELECTRICAL PERMIT FEES 51.75ഀ WC 00100003112800 WILL CALL INSPECTION FEE 3.00ഀ FROM :SHAW ELECTRIC FAX NO. :9709263358 Nov. 14 2006 08:57AM P1ഀ T0WN OF YK T~ഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ Electrical Contractor:ഀ Cnntractor Sionature: i iഀ AMOUNT OF SQ FT IN STRUCTURE:ഀ Town of Vail Reg.ഀ e- 1D (119ഀ andഀ Project `j • vഀ pN;, 9Buildiug Permitഀ Electrical Permit ,ഀ pRMATIONഀ C=/ nd Phone #'s: olz(oഀ ~*v.&kero 37(p -lowz-ഀ ELECTRICAL VALUAT ION: $ (L6Zjഀ *,e*****x*e.,wW~~***,,•.*.*,**sert~******FOROFFICE USEONLY**«*****~e,e•«~**#~.•****~,~.«***#*R,~ഀ Y/ഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ ELECTRICAL PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ Legal Description: " t~ 3 CbG~ ' ti Coഀ Project Noഀ OWNER DAYTON, JOHN W. & ARLENE J. 10/04/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT SHAW ELECTRICഀ P O BOX 1451ഀ AVON COഀ CO 81620ഀ License: 106-Eഀ CONTRACTOR SHAW ELECTRICഀ P O BOX 1451ഀ AVON COഀ CO 81620ഀ License: 106-Eഀ Permit E07-0254ഀ _1'0(:~-0~&~ t ~'~o Iഀ Statusഀ ISSUEDഀ Applied..:ഀ 10/04/2007ഀ Issued.ഀ 10/05/2007ഀ Expires .ഀ 04/02/2008ഀ 10/04/2007 Phone: 970-926-3358ഀ 10/04/2007 Phone: 970-926-3358ഀ Desciption: ELECTRICAL FOR REMODEL/ADDITION TO SFRഀ Valuation: $0.00 Square feet: 8200ഀ a«zഀ FEE SUMMARYഀ Electrical >ഀ $371.45ഀ Total Calculated Fees-->ഀ $375.45ഀ Investigation >ഀ $0.00ഀ Additional Fees >ഀ $0.00ഀ Will Call >ഀ $4.00ഀ Total Permit Fee-------->ഀ $375.45ഀ TOTAL FEES-->ഀ $375.45ഀ Payments >ഀ $375.45ഀ BALANCE DUE-------->ഀ $0.00ഀ ഀ ഀ ഀ Approvals:ഀ Item: 06000 ELECTRICAL DEPARTMENTഀ 10/04/2007 shahn Action: APഀ ഀ CONDITIONS OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town'ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV NCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.ഀ i ~ 1ഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R070002117 Amount: $375.45 10/05/200702:18 PMഀ Payment Method: Check Init: LCഀ Notation: #15393/SHAWഀ ELECTRICഀ ഀ Permit No: E07-0254 Type: ELECTRICAL PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $375.45ഀ This Payment: $375.45 Total ALL Pmts: $375.45ഀ Balance: $0.00ഀ ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ EP 00100003111100 ELECTRICAL PERMIT FEES 371.45ഀ WC 00100003112800 WILL CALL INSPECTION FEE 4.00ഀ ഀ FROM :SHAW ELECTRICഀ rഀ rഀ iഀ FAX NO. :9709263358ഀ Oct. 04 2007 07:27AM P1ഀ r ~ vJwr ts-.ഀ Building Permit E07. 045v~ഀ flettrical Permitഀ TOWN OF VAIL TOഀ 75 S. Fron age Rd.ഀ Vail, Colada 81657ഀ CONTRACTOR INFORMATIONഀ Electrical Contractor: Town of Vail Reg. No,,. Co ct and Phone Vs: 37& - [ d3 Z-ഀ Contractor Sianature: iiഀ AMOUNT OF SQ FT IN Sf'ftUCTURE:ഀ 1ഀ Job Name:ഀ Legal Description lot: Block:ഀ Owners Name:ഀ d VALUATIONS FOR ALL 0THERS h bor & Melterialഀ Z a~ ELECTRICAL VALUA ti 1014: $ 10 a cxs. ~ഀ Job Address: 3- { 3 eaLVA ~cc m.ഀ Filing: Subdivision:ഀ Uf. + , Phone:ഀ Engineer: r►oaress: _ഀ Detailed Ioescriptibn of work:ഀ )ഀ Wo Class: New ) Addition ( ) Remodel { ) Repair ( ) Tamp Power( ) Other(ഀ Work Type: Interior ( ) Exterior ( Both ( ) Does an EHU exist at this location: Yes (No ( )ഀ Type of Bldg.: Single-family ) Duplex ( ) Multi-family ( ) Commerdai { ) Restaurant { ) Other ( )ഀ F. of Existing Dwelling Un~ s in this building: No. of Accommodation Units. in this building.ഀ S this ermit far a hot tub: Yt Naഀ netac a Fire Snrinkler System E}C9 Yes( ) No ( )ഀ YYRAt rE##*##****akR 4t YEA#*#***RR7tiR###***YeaA## OFFICE USEഀ ~3~y4Sഀ P:/everyone/fnrms/elec"rmഀ t.~ y 0 3 20D 1ഀ TOWN OF VAIL .ഀ TOWN OF VAILഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTEഀ ELECTRICAL PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ Legal Description: 4rp _ bഀ Project No :ഀ OWNER DAYTON, JOHN W.ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT MD MOLLER COഀ PO BOX 1508ഀ EDWARDSഀ CO 81632ഀ License: 355-Eഀ CONTRACTOR MD MOLLER COഀ PO BOX 1508ഀ EDWARDSഀ CO 81632ഀ License: 355-Eഀ Desciption: New electricalഀ Valuation: $200,000.00ഀ & ARLENE J. 03/24/2008ഀ Permit E08-0035ഀ &-C)Sഀ Statusഀ ISSUEDഀ Applied..:ഀ 03/24/2008ഀ Issued .ഀ 03/26/2008ഀ Expires.ഀ 09/22/2008ഀ 03/24/2008 Phone: (970) 569-3913ഀ 03/24/2008 Phone: (970) 569-3913ഀ Square feet: 8200ഀ FEEഀ SUMMARYഀ Electrical >ഀ $371.45ഀ Total Calculated Fees-->ഀ $375.45ഀ Investigation >ഀ $ 0 .00ഀ Additional Fees >ഀ $0.00ഀ Will Call >ഀ $4.00ഀ Total Permit Fee-------->ഀ $375.45ഀ TOTAL FEES-->ഀ $375.4Sഀ Payments >ഀ $375.45ഀ BALANCE DUE-------->ഀ $0.00ഀ ഀ ഀ ഀ Approvals:ഀ Item: 06000 ELECTRICALഀ DEPARTMENTഀ 03/25/2008 shahnഀ Action: APഀ Item: 05600 FIRE DEPARTMENTഀ CONDITIONS OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.ഀ DEPARTMENT OF COMMUNITY DEVELOPMENTഀ THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV4NCE I\Y/F> hEPUONE AT 479,-2149 OR AT OUR OFYICE FROM 8:90 AM - 4 PM.ഀ SIGNATURI'OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNERഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R080000344 Amount: $375.45 03/26/200801:48 PMഀ Payment Method: Check Init: DDGഀ Notation: MD Mollerഀ Company Inc. 8044ഀ ഀ Permit No: E08-0035 Type: ELECTRICAL PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $375.45ഀ This Payment: $375.45 Total ALL Pmts: $375.45ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ EP 00100003111100 ELECTRICAL PERMIT FEES 371.45ഀ WC 00100003112800 WILL CALL INSPECTION FEE 4.00ഀ ഀ FROM 03 21 2008 13:49/ST.13:48 P002ഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UN IGN Dഀ Project 2..ഀ Building Permitഀ *Y'Aal Electrical Permit #1M- n01ഀ Iu1FC~Y NsFik 970-479-2149 (Inspections)ഀ 75 S. Frontage Rd.ഀ Vail, Colorado 81657ഀ TOWN OF VAIL ELECTRICAL PERMIT APPLICATIONഀ CONTRACTOR INFORMATIONഀ Electrical Contracto L Town of Vail Reg. No.: ntact P rson a Phone #'s:ഀ 2-)C- - E - 1(ഀ iഀ (IKഀ E-Mail Address: Fax#: S'.ഀ Contractor Signature: I-V49/0ALഀ COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials)ഀ AMOUNT OF SQ FT IN STRUCTURE: ELECTRICAL VALUATION: $ഀ Contact Fan/a rnnnty dccaccnrr of a at 97n.".q-J? dD nr vicif www,oan1P-rnrinh1 t-Am &P Dared! fEഀ Parcel # I C) i C57 1'~ n .ഀ Job Name:ഀ Job Address:ഀ Legal Descriptionഀ Lot:ഀ Block:ഀ Filing:ഀ [Subdivision;ഀ Own s Na e:J A" a L)ഀ e_ഀ Phone:ഀ Engineer: Address:ഀ Phone:ഀ Detailed description of work: , ` V I~. _ •ഀ Work Gass: New Addition ( ) Remodel ( )ഀ Repair ( ) Temp Power ( ) Other ( )ഀ Work Type: Interior ( ) Exterior ( ) Both ' )ഀ Does an EHU exist at this location: Yes( ) Nഀ Type of Bldg.: Single-family Duplex ( ) Multifamily ( )ഀ Commercial ( ) Restaurant ( ) Other ( )ഀ F No. of Existing Dwelling Units In this building:ഀ No. of Accommodation Units in this building:ഀ Is this permit for a hot tub: Yes Noഀ Does a Fire Alarm Exist: Yes( ) Noഀ Does a Fire Sprinkler System Exist: Yes(ഀ ) Noഀ ****wwwww><**wwwwwwwwwrwxwwxM,r**sc*x****FOR OFFICE USE ONLY**""k*******xഀ Other Fees:........:..:,.;.:.:.::.:.:...ഀ Date Recefyed:..:. .ഀ : DRB Fees:..ഀ : AcCe ted B , .ഀ • Planner Si n-off:..ഀ ഀ F: \cdev\FORMS\Permits\Buildi ng\elecdcal-permit_11.23-2005-DOCഀ 1ഀ C F 0~Eഀ MAR 2 1 ZgPJ8ഀ cl~ Page 1 of 2ഀ N OF VAIIഀ 11/23/2005ഀ FROM 03 21 2008 13:49/ST.13:48 P003ഀ MiW Aഀ Amendment to the 2002 N.E.C. Town of Vail Ordinance 4 Series of 2005ഀ ❑ overhead services are not allowed in the Town of Vail.ഀ ❑ Underground services shall be in conduit (PVC) from the utility transformer to the electric meter, mainഀ disconnect switch, and to the first electrical distribution circuit breaker panel.ഀ ❑ The main disconnect switch shall be readilyaccessible, andlocated next to the meter on the exterior wall ofഀ the structure. All underground conduits are required to be inspected before back-filling the trench.ഀ ❑ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Commonഀ walls and spaces are exempt.ഀ ❑ NM Cable (Romex) can be used only in single and mull-famify dwellings not erreeding 3 storiesഀ Type NM cannot be used in any building mixed with T)pe A.B.E,FH,I,M &S occupandes.ഀ ❑ Aluminum conductors smaller than size #8 are not permitted.ഀ TOWN F VAIL ELECTRICAL PERMIT GUIDELINESഀ ❑ All installations of exterior hot tubs or spa's require a DRB approval from planning. This application willഀ not be accepted without a copy of the DRB approval form attached (if applicable).ഀ ❑ If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck overഀ 30" above grade, you must also obtain a building permit.ഀ ❑ If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform,ഀ a structural engineer must review the existing condition and verify that it will support the addedഀ concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawingഀ with this application.ഀ ❑ If this is a remodel in a multi-family building with a homeowners association, a letter of permissionഀ from the association is required.ഀ ❑ If this permit is for a commercial space, two (2) sets of stamped drawings are required. Electricalഀ one line and panel schedules are required if load is added or distribution is altered.ഀ I have read and understand the above.ഀ ff'ഀ ?4J- 0ഀ 9igt'rtature Date Signedഀ If you have any questions rega ii.~g the above information or have additional questions,ഀ please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can beഀ reached on Monday thru Friday mornings between the hours of Barn and 9am. You may alsoഀ leave a voice mail and the inspector will call you back.ഀ r-,Vdcv\FORMS\Permits\Building\elecdcal-permiL11.23-2005.DOC Page 2 of 2 11123/2005ഀ FROMഀ 03 21 2008 13:49/ST.13:48 P001ഀ M.D. Moller COഀ ELECTRICAL CONTRACTINGഀ P.O. Box 1508 Edwards, CO 81632 (970) 845-6039 (970) 845-8029 FAXഀ FAX TRANSMITTAL SHEETഀ COMPANY NAME: Town of Vailഀ ATTENTION: Community Developmentഀ FAX NUMBER: 970-479-2452ഀ FROM: Deidreഀ DATE: 3/21/08ഀ TOTAL PAGES INCLUDING COVER: 3ഀ COMMENTS:ഀ Electrical Permit Applicationഀ Please call with any questions.ഀ Thank you,ഀ DeLdre Romeroഀ M.D. Moller Companyഀ TOWN OF VAILഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTEഀ MECHANICAL PERMITഀ Permitഀ Status :ഀ Applied :ഀ Issued . . .ഀ Expires.ഀ M08-0005ഀ 03"~ _7 - O 1~tഀ ISSUEDഀ 01/03/2008ഀ 01/16/2008ഀ 07/14/2008ഀ Job Address:ഀ 344 BEAVER DAM RD VAILഀ Location.....:ഀ 344 BEAVER DAM RDഀ Parcel No...:ഀ 210107113012ഀ Legal Description:ഀ . ~ s o oഀ Project No :ഀ OWNER DAYTON, JOHN W. & ARLENE J. 01/03/2008ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT KAIBAB PLUMBING INC.ഀ P.O. BOX 1451ഀ EAGLEഀ CO 81631ഀ License: 249-Mഀ CONTRACTOR KAIBAB PLUMBING INC.ഀ P.O. BOX 1451ഀ EAGLEഀ CO 81631ഀ License: 249-Mഀ 01/03/2008 Phone: 970-390-7735ഀ 01/03/2008 Phone: 970-390-7735ഀ Desciption: INSTALL INFLOOR HEAT, SNOWMELT, SPA HEAT SUPPLY ANDഀ HYDRONIC CONTROLSഀ Valuation: $89,200.00ഀ Fireplace Information: Restricted: # of Gas Appliances: 0 # of Gas Logs: 0 # of Wood Pellet: 0ഀ FEE SUMMARYഀ Mechanical $1, 800. 00 Restuarant Plan Review--> $0.00 Total Calculated Feesഀ $2,254.00ഀ Plan Check $450.00 TOTAL FEES-------------->ഀ $2,254.00 Additional Fees-----------> $0.00ഀ Investigation-> $0. 00 Total Permit Fee---------- >ഀ $2,254.00ഀ Will Call-----> $4 .0 0 Payments > $2,254.00ഀ BALANCE DUE--------- > $ 0 . 00ഀ ഀ Item: 05100 BUILDING DEPARTMENTഀ 01/03/2008 cgunion Action: APഀ CONDITION OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ Cond: 22ഀ (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTIONഀ 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.ഀ Cond: 23ഀ (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS ANDഀ CHAPTER 10 OF THE 2003 IMC.ഀ Cond: 25ഀ DEPARTMENT OF COMMUNITY DEVELOPMENTഀ THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.ഀ Cond: 29ഀ (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003ഀ IMC AND CHAPTER 3 OF THE 2003 IFGC..ഀ Cond: 31ഀ (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESSഀ LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.ഀ Cond: 32ഀ (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIORഀ TO AN INSPECTION REQUEST.ഀ Cond: 30ഀ (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVEDഀ MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zon and subdivision codes, design reviewഀ approved, International Building and Residential Codes and other orditrpnses of t own applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANC'B JIPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM.ഀ SIGNA-FW OF Q'WNER~OR CONTRACTOR FOR HIMSELF AND OWNERഀ TOWN OF VAIL, COLORADO Statementഀ Statement Number: R080000062 Amount: $2,254.00 01/16/200810:54 AMഀ Payment Method: Check Init: DDGഀ Notation: Kaibab 3233ഀ ഀ Permit No: M08-0005 Type: MECHANICAL PERMITഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location: 344 BEAVER DAM RDഀ Total Fees: $2,254.00ഀ This Payment: $2,254.00 Total ALL Pmts: $2,254.00ഀ Balance: $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Current Pmtsഀ ഀ MP 00100003111100 MECHANICAL PERMIT FEES 1,800.00ഀ PF 00100003112300 PLAN CHECK FEES 450.00ഀ WC 00100003112800 WILL CALL INSPECTION FEE 4.00ഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN ii~ ~lഀ TOV Project cJഀ 00 Building Permitഀ Mechanical Permitഀ TOWN 16 0 swmo~ 970-479-2149 (Inspections)ഀ IM TOഀ WN OF VAIL MECHANICAL PERMIT APPLICATIONഀ 75 S. Frontage Rd. Permit will not be accepted without the following:ഀ Vail, Colorado 81657ഀ / Provide Mechanical Room Layout drawn to scale to include:ഀ P-- Mechanical Room Dimensions eN P14-75ഀ u, Combustion Air Duct Size and Location 8`/ orhh-V Sഀ /J c?- Flue, Vent and Gas Line Size and Location aN ~s/ ~s~~ SPsഀ u,- Heat Loss Calcs.ഀ v- Equipment Cut/Spec Sheetsഀ CONTRACTOR INFORMATIONഀ Mechanical Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:ഀ 1,016* 11 1 .1 vi 5 v n4ex tk" p 9 70 396 7 7 3,_ഀ E-Mail Address: a~ h 4,,0 4 e_ M; yA Fax#: ?70 326 773 12-ഀ 1 Aഀ VALUATION FOR MECHANICAL PERMIT (Labor & Materialsഀ II MECHANICAL: $ 6?, Zap ~ IIഀ Contact Eaale County dSSecsnrc nmrp at 97n- 37R-RF,4n nr vicit unenei awn/a_i nhi i-nm 0^r Dm.• l vVഀ Parcel # 210107113o/2ഀ Job Name: P. KRAJ Ar 5/10FN,::~-Eഀ Job Address: 3vy - ~ .46ഀ Legal Description Lot:ഀ D I Block: Filing: Subdivision:ഀ Owners Name: T*4W /aRN Eഀ Phഀ Address: 2703 ~WrH STNF 7 5 11ഀ 7ഀ Engineer: Address: hഀ Detailed description of work: SivalwM67; 6,-,A yRAr SaepLY, oLSJ,A 3 2096ഀ Work Class: New Addition( ) Alteration ( ) Repair ( ) Other( ) OF \/AILഀ Boiler Location: Interior (>4) Exterior ( ) Other ( ) Does an EHU exist is ovation: Yes( ) No ( )ഀ Type of Bldg: Single-family 9C) Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( )ഀ No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:ഀ No /Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burninഀ [No ype of Fireplaces Proposed: Gas Appliances (s~) Gas Logs Wood/Pellet ( ) Wood Burning (NOT ALLOWED)ഀ Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No ~e)ഀ ************************FOR OFFICE USE ONLY*****************************ഀ F:\cdev\BUI1DING\APPLICATIONS\MECHPERM2005.DOC 06/08/2005ഀ rC6 4,631 -,,7vtv7ഀ KAIBAB'PLUMBINGഀ ANDഀ JUFERGU11111S..ONഀ Wഀ Hydronicsഀ THE DAYTONഀ RESIDENCEഀ HYDRONIC SYSTEM DESIGNഀ ANDഀ MECHANICAL PRODUCT SUBMITTALഀ + joi-rkoL 5u,6,i4117?qf-ഀ VAAഀ TAY-`am I~,s)oENcjഀ Bain R S►ഀ Iഀ spyഀ H X.3ഀ s~ഀ Qഀ 13dPoo arvഀ DHw P6ഀ IRഀ KSN Soo,cC0ഀ BP, 460#464ഀ Xg sENrഀ rഀ TSഀ BPzഀ Bot La 2ഀ IBM 606)OWഀ euurrഀ P3ഀ e.m f4ഀ HYD•ഀ XT- Iഀ SPA P7ഀ SKOWMELrഀ 1A - 1ഀ 4 25,Eഀ 67Dഀ .S.M.ഀ kr. 2ഀ .TFH p;ഀ Pbh K d /z "ഀ M4) Neiഀ W~VVഀ t s'o,OCO Bruഀ ~ഀ rഀ aഀ SMPSഀ S'razRar~t~ഀ iഀ Pump # Location Designationഀ GPMഀ Ft./ Hd. Flange size Main sizeഀ 1 Boiler 1 UP 43-110ഀ 47ഀ 23 1 1/2" 1 1/2"ഀ 2 Builer 2 UP43-110ഀ 47ഀ 23 1 1/2" 1 1/2"ഀ 3 Main Circ. UPS 50-40ഀ 120ഀ 5 1 1/2'x 3" 3"ഀ 4 Snowmelt UPS 43-44ഀ 38ഀ 1 1/2"x2" 2"ഀ heatഀ 5 Snowmelt UPS 43-44ഀ 38ഀ 6.1 11/2"x21/2" 2 1/2"ഀ circഀ 6 Radiant UPS26-99ഀ 16.5ഀ 4.8 1 1/2" 1 1/2"ഀ supplyഀ 7 Spa H-X UPS26-99ഀ 25ഀ 10 1 1/2" 1 1/2"ഀ 8 Pump St. 1 UPS 15-58ഀ 5.9ഀ 4.8 1 1/2" 1 1/2"ഀ 9 Pump St. 2 UPS 15-58ഀ 4.7ഀ 2.2 1 1/4" 1 1/4"ഀ 10 Pump St. 3 UPS 15-58ഀ 5.7ഀ 3.7 1 112" 1 1/2"ഀ Other Mechanical equipmentഀ Boilersഀ Lochinvar KBN-500ഀ DHW Sidearm tanksഀ Triangle Tube Smart 120 (2ea)ഀ Snowmelt Heat exchangerഀ Carlson 10.0 1 1/4" boiler side 1 1/2" service siഀ Radiant mixing valveഀ Tekmar 4-way Model #722 1 1/4"ഀ Hydronic Air"Separatorഀ Spirovent Jr. 3" IPS connectionഀ Snowmelt Air Separatorഀ Spirovent Jr. 2 1/2" IPS connectionഀ Hydronic Expansion tankഀ Amtrolഀ Snowmelt expansion tankഀ Amtrolഀ Domestic hot water expansion tankഀ Amtrolഀ All pumpsഀ manufacturedഀ by Grundfossഀ All pumpsഀ with integralഀ check valvesഀ where availableഀ Nഀ Nഀ 5ഀ r ~ { {ഀ k jj ~ (tF ;ഀ } ~ k i Iഀ i {ഀ {ഀ 3ഀ }ഀ 1ഀ t ~ Q €ഀ ✓ Fഀ VN c~..-ഀ Radiant Works 2002.07 Zone List 06-13-2007ഀ Project Informationഀ Project Name: DAYTON SNOWMELTഀ Project Number: Project Quote:ഀ Designed For: KAIBAB PLUMBINGഀ Phone Number:ഀ Fax Number:ഀ Notes:ഀ ALL MEASUREMENTS PER PLANS. VERIFY.ഀ Contact Informationഀ Designed By: JAKE FEARഀ Company Name: FERGUSONഀ Phone Number: 303.320.4833ഀ Fax Number: 303.355.0408ഀ ALL SLAB ASSUMED TO HAVE ATLEAST.5" INSULATION. VERIFY.ഀ ALL SLAB PERIMETER ASSUMED INSULATED. VERIFY.ഀ ALL SUPPLY AND RETURN LENGTHS ASSUMED, VERIFY.ഀ MUST USE NO-BURST ALUMINUM SAFE GLYCOL WITH THIS BOILER.ഀ ~/1IGU/iuAZI'ഀ Zone 1 (Snowmelt) V2ഀ Room Soecificafionsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ [in]ഀ [ft2lഀ Btu/hഀ Btu/hഀ Btulhഀ SM 1- DRIVEWAYഀ 10ഀ -ഀ -ഀ 135.3ഀ 326,969ഀ 471,151ഀ (Zone Specificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 108ഀ 30ഀ 24.7ഀ 8.2ഀ 337,789ഀ 5/8"ഀ 200ഀ 16ഀ RadiantPEഀ Xഀ _rഀ Pump Specs & Radiant Panel Loan are calculated on the smauer ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 2 (Snowmelt)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ lഀ tensityഀ Heatഀ Capacityഀ ~nഀ inഀ u/hഀ Btu/hഀ Btu/hഀ SM 2- LOWERഀ 10ഀ 643ഀ -ഀ -ഀ 135.3ഀ 86,984ഀ 125,443ഀ DECKഀ SM 2- STAIRSഀ 10ഀ 165ഀ -ഀ -ഀ 135.3ഀ 22,321ഀ 32,21-6-ഀ COOഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 1ഀ Radiant Works 2002.07 Zone Listഀ Zone Specificationsഀ 06-13-2007ഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid rF]ഀ [°F]ഀ Ift]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ [Stu/hlഀ 108ഀ 30ഀ 8.2ഀ 5.8ഀ 112,322ഀ 5/8"ഀ 175ഀ 6ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 3 (Snowmelt)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ tingഀ Tഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ jIntഀ eഀ nsItyഀ Heatഀ Capacityഀ inഀ inഀ ft$ഀ /ഀ hഀ Btulhഀ tu/hഀ SM 3- MASTERഀ 10ഀ 117ഀ -ഀ -ഀ 135.3ഀ 15,828ഀ 18,023ഀ DECKഀ Iഀ ഀ 5M 3- ROOF #1ഀ 10ഀ -ഀ -ഀ 135.3ഀ 17,316ഀ 17,324ഀ Iഀ Zone Specificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ INഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ tu/hഀ 108ഀ 30ഀ 2.5ഀ 4.9ഀ 33,911ഀ 5/8"ഀ 175ഀ 2ഀ RadlantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 4 (Snowmelt)ഀ Rnnm RnAnifinationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ [in]ഀ [ft2jഀ inഀ Btulhഀ Stu/hഀ Btuihഀ SM 4- NORTHഀ 10ഀ JW-ഀ -ഀ -ഀ 135.3ഀ 26,515ഀ 30,192ഀ GAME DECKഀ 7nna Gnmr_ifinnfinnsഀ supplyഀ Delta Tഀ GPMഀ ~vHeadഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ Ift]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ tu/hഀ 108ഀ 30ഀ 2.0ഀ 2.4ഀ 27,110ഀ 5/8"ഀ 125ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Loan are catcwateu un ME; srijauc viഀ DAYTON SM.rad Copyright(c) Watts Radiantഀ Page 2ഀ Radiant Works 2002.07 Zone Listഀ Required Heat or Radiant Capacity back and edge losses)ഀ 06-13-2007ഀ Zone 5 (Snowmelt)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ On]ഀ [in)ഀ [ft2lഀ Btulh ftjഀ Btulhഀ Stulhഀ SM 5- SOUTHഀ 10ഀ ABTഀ -ഀ -ഀ 135.3ഀ 65,340ഀ 74,250ഀ GAME DECKഀ 160ഀ Zone Spec'lficafionsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tuneഀ No. ofഀ Fluid [°F]ഀ CFIഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ [Bt!;/hlഀ 108ഀ 30ഀ 5.0ഀ 4.9ഀ 67,617ഀ 518"ഀ 175ഀ 4ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 6 (Snowmelt) ALഀ Room Specificafionsഀ Room Naഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ _JRAidtfintഀ acingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Ham'ഀ Capaartyഀ Inഀ inഀ Btulhഀ tulhഀ Btulhഀ SM 6- ROOF #2ഀ 10ഀ -ഀ ഀ 29,356ഀ 33,393ഀ Zone So, c onsഀ Supplyഀ Delta Tഀ GPMഀ Hand-ഀ Radiantഀ -.productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ ഀ [ft]ഀ Panelഀ Type.,--ഀ Length [ft]ഀ Circuitsഀ Loadഀ tulhഀ 4ഀ 108ഀ 0ഀ 2.2ഀ 3.5ഀ 30,309ഀ 51W'ഀ 150ഀ 2ഀ RadiantPEഀ Xഀ _rഀ a.ഀ Pump Specs & Radiant Panel Load are caicuiateo on the smatter orഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 7 (Snowmelt)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ inഀ B#dhഀ tulhഀ tu/hഀ SM 7- LOFT DECKഀ 10ഀ 128ഀ -ഀ -ഀ 135.3ഀ 17,316ഀ 19,697ഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 3ഀ Radiant Works 2002.07 Zone Listഀ Zone Specificationsഀ 06-13-2007ഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ [Btu/hlഀ 108ഀ 30ഀ 1.3ഀ 5.4ഀ 17,825ഀ Wഀ 175ഀ 1ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Project Totalsഀ Radiant System Pumping Specs: 45.9 GPM at 8.2 feet of head. (excluding Supply & Return piping.)ഀ Radiant System Boiler Load: 626883 Btu/h (excluding Supply & Return piping losses and Aux. Heat,ഀ if required)ഀ 6025' of 5/8" RadlantPEXഀ * Report not valid unless Assumption Report has been verified.ഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 4ഀ Radiant Works 2002.07 Assumption Report 06-13-2007ഀ Project Informationഀ Project Name: DAYTON SNOWMELTഀ Project Number. Project Quote:ഀ Designed For: KAIBAB PLUMBINGഀ Contact Informationഀ Designed By: JAKE FEARഀ Company Name: FERGUSONഀ Phone Number: 303.320.4833ഀ Fax Number: 303.355.0408ഀ Phone Number:ഀ Fax Number:ഀ ALL MEASUREMENTS PER PLANS. VERIFY.ഀ Notes:ഀ ALL SLAB ASSUMED TO HAVE ATLEAST.5" INSULATION. VERIFY.ഀ ALL SLAB PERIMETER ASSUMED INSULATED. VERIFY.ഀ ALL SUPPLY AND RETURN LENGTHS ASSUMED, VERIFY.ഀ MUST USE NO-BURST ALUMINUM SAFE GLYCOL WITH THIS BOILER.ഀ Project Assumptionsഀ OutsideTeഀ Elevationഀ Windഀ Glycolഀ Job Typeഀ Systemഀ mp rF]ഀ [ft]ഀ Speedഀ Chemicalsഀ [mph]ഀ -20ഀ 8500ഀ 10ഀ Propyleneഀ Residentialഀ Noഀ 50%ഀ Zone 1 (Snowmeit) [5/8" RadiantPE qഀ Min Tube Length:ഀ 20 ftഀ Max Tube Length:ഀ 200 ftഀ Circuit Roundin :ഀ 25 ftഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 Fഀ Manifold Distance:ഀ 0 ftഀ Tem :ഀ Thickness Belowഀ 2 inഀ Thickness Aboveഀ 2 inഀ Slab Conductivity:ഀ 0.81 Btu/h ftഀ Tube:ഀ Tube:ഀ Fഀ SM 1- DRIVEWAYഀ Rnnm r-nnstructien Parameters:ഀ Area:ഀ 2417 ft2ഀ Perimeter.ഀ 262 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ft Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab insulationഀ 2417 ftzഀ Area:ഀ Horizontalഀ 0.5 in"ഀ Exposed Slabഀ 262 ft Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeterഀ Btu/h ftaഀ Thickness:ഀ Slab Perimeterഀ 262 ftഀ Perimeterഀ 4 ft Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Intensi Area:ഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 1ഀ Radiant Works 2002.07 Assumption Reportഀ 06-13-2007ഀ Zone 2 (Snowmelt) [5/8" RadiantPEX]ഀ Min Tube Length:ഀ 20 itഀ Max Tube Length:ഀ 200 ftഀ Circuit Rounding:ഀ 25 itഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 Fഀ Manifold Distance:ഀ 0 ftഀ Tem :ഀ Thickness Belowഀ 2 inഀ Thickness Aboveഀ 2 inഀ Slab Conductivity:ഀ 0.81 Btu/h-ftഀ Tube:ഀ Tube:ഀ Fഀ * Please verify the indicated items for accuracyഀ SM 2- LOWER DECKഀ Room Construction Parameters:ഀ Area:ഀ 643 ft'ഀ Perimeter.ഀ 142 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheiiding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab Insulationഀ 643 1`12ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 73 itഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter.ഀ Btu/h ft2ഀ Thickness:ഀ Slab Perimeterഀ 73 itഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Iഀ lntensi Area:ഀ SM 2- STAIRSഀ Room Construction Parameters:ഀ Area:ഀ 165 ft2ഀ Perimeter.ഀ 54 itഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheiiding:ഀ 1ഀ Ground:ഀ .Class:ഀ 2ഀ Space Below:ഀ Slab 'Insulationഀ 165 ft2ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 54 itഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter:ഀ Btu/h ft2ഀ Thickness:ഀ Slab Perimeterഀ 54 ftഀ Perimeterഀ 4 itഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 it-ഀ Intensity Area:ഀ Zone 3 (Snowmelt) [5/8" RadiantPE)qഀ Min Tube Len th:ഀ 20 itഀ Max Tube Length:ഀ 200 ftഀ Circuit Rounding:ഀ 25 ftഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 Fഀ Manifold Distance:ഀ 0 ftഀ Temp:.ഀ Thickness Belowഀ 2 inഀ Thickness Aboveഀ 2 inഀ Slab Conductivity:ഀ 0.81 Btulh-ftഀ Tube:ഀ Tube:ഀ Fഀ * Please verify the indicated items tar accuracyഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 2ഀ Radiant Works 2002.07 Assumption Reportഀ SM 3- MASTER DECKഀ Room Construction Parameters:ഀ 06-13-2007ഀ Area:ഀ 117 ft2ഀ Perimeter:ഀ 54 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab Insulationഀ 117 ft2ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 28 Itഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter.ഀ Btu/h ft2ഀ Thickness:ഀ Slab Perimeterഀ 28 Itഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Intensity Area:ഀ 1 st Layerഀ 0.75 inഀ Conductivity:ഀ 1.07 Btu/h-ftഀ Thickness:ഀ F*ഀ SM 3- ROOF #1ഀ Room Construction Parameters:ഀ Area:ഀ 128 ft2ഀ Perimeter:ഀ 47 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab insulationഀ 128 ft2ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 21 ftഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter:ഀ Btu/h ft2ഀ Thickness:ഀ Slab Perimeterഀ 21 ftഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 fFഀ Intensity Area:ഀ 1 st Layerഀ 0.75 inഀ Conductivity:ഀ tu/h-ftഀ 0.638ഀ Thickness:ഀ F*ഀ Zone 4 (Snowmelt) [518" RadiantPEX]ഀ Min Tube Len th:ഀ 20 ftഀ Max Tube Len th:ഀ 200 ftഀ Circuit Roundin :ഀ 25 ftഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 F.ഀ Manifold Distance:ഀ 0 ftഀ Tem :ഀ Thickness Belowഀ 2inഀ Thickness Aboveഀ 2 inഀ Slab Conductivity:ഀ 0.81 Btu/h-ftഀ Tube:ഀ Tube:ഀ Fഀ * Please verify the Indicated memo Tor accuracyഀ SM 4- NORTH GAME DECKഀ f?nnm r`nna- - rrsctinn Parameters.ഀ Area:ഀ 196 f#2ഀ Perimeter. ~ഀ 57 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheilding:ഀ 1ഀ Ground:ഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 3ഀ Radiant Works 2002.07 Assumption Reportഀ Room Construction Parameters:ഀ 06-13-2007ഀ Area:ഀ 217 ft2ഀ Perimeter.ഀ 64 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 Itഀ Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab Insulationഀ 217 It'ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 64 Itഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeterഀ Btu/h f12ഀ Thickness:ഀ Slab Perimeterഀ 64 ftഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Intensity Area:ഀ 1 st Layerഀ 0.75 inഀ Conductivity:ഀ 1.07 Btu/h-f1ഀ Thicknessഀ F*ഀ Zone 7 (Snowmelt) [518" RadiantPEX]ഀ Min Tube Length:ഀ 20 Itഀ Max Tube Length:ഀ 200 Itഀ Circuit Roundin :ഀ 25 ftഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 Fഀ Manifold Distance:ഀ 0 ftഀ Tem :ഀ Thickness Belowഀ 2 in .ഀ Thickness Aboveഀ 2 inഀ Slab Conductivity:ഀ 0.81 Btu/h-ftഀ Tube:ഀ Tube:ഀ Fഀ * Please verify the indicated items for accuracyഀ SM 7- LOFT DECKഀ Rnnm (Inn-Oninffnn Parameters:ഀ Area:ഀ 128 ft-2ഀ Perimeter:ഀ 47 Itഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 itഀ Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab Insulationഀ 47 ft2ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 35 Itഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter:ഀ Btu/h 1112ഀ Thickness:ഀ Slab Perimeterഀ 35 Itഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Intensity Area:ഀ 1st Layerഀ 0.75 inഀ Conductivity:ഀ 1.07 Btu/h-ftഀ Thickness:ഀ Signature:ഀ DAYTON SM.rad Copyright(c) Watts Radiantഀ Date:ഀ Page 5ഀ vഀ Z v~ഀ ue_ഀ k og/- I velഀ xഀ ocഀ kഀ C4ഀ -9 o ttd►ഀ No 4ഀ zz~ഀ nഀ Qഀ 70ഀ sഀ IX 1 37ഀ IA iഀ INSഀ Itoഀ Cry E fiat "--J O ! ~1'l - f O `y,} V~ഀ mow..ഀ ,D r - E w "00ഀ ,ഀ tഀ ra N Nഀ Tഀ g Cഀ f Cഀ Qഀ 77ഀ °'tഀ rഀ tdvഀ ~ഀ eഀ .~..tL.aഀ Radiant Works 2002.07 Assumption Reportഀ 2 l Space Below:ഀ Area:ഀ 06-13-2007ഀ 196 ft'ഀ Horizontalഀ 0.5 in*.ഀ Exposed Slabഀ 31 ftഀ Heating Intensity:ഀ 135.28ഀ Insulationഀ Perimeter:ഀ Btu/h ft2ഀ Thickness:ഀ Slab Perimeterഀ 31 ftഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ft2ഀ Intensi Area:ഀ 1 st Layerഀ 0.75 inഀ Conductivity:ഀ 1.07 Btu/h ft-ഀ Thickness:ഀ F*ഀ Zone 6 (Snowmelt) [!N" RadiantPEX}ഀ Min Tube Len th:ഀ 20 ftഀ Max Tube Len th:ഀ 200 ftഀ Circuit Roundin :ഀ 25 ftഀ Supply Waterഀ 108 Fഀ Delta T:ഀ 30 Fഀ Manifold Distance:ഀ 0 ftഀ Tem :ഀ Thickness Belowഀ 2 inഀ Thickness Aboveഀ 2 inഀ Slab Conductivity.ഀ 0.81 Btu/h-ftഀ Tube:ഀ Tube:ഀ Fഀ * Please verify the indicated items for accuracyഀ SM 6- SOUTH GAME DECKഀ a....... A....~f...nflnn Dmrnmatar c.ഀ Area:ഀ 483 ft2ഀ I~VV/11 yY..VY 4v..vഀ Perimeter.ഀ ~ഀ 163 ftഀ Max Snowfall:ഀ 24 in/day*ഀ Height Aboveഀ 0 ftഀ Sheilding:ഀ 1ഀ Ground:ഀ Class:ഀ 2ഀ Space Below:ഀ Slab Insulationഀ 483 ft'ഀ Area:ഀ Horizontalഀ 0.5 in*ഀ Exposed Slabഀ 90 ftഀ Heating Intensity:ഀ hഀ Btuഀ Insulationഀ Perimeter:ഀ /ഀ Wഀ Thickness:ഀ Slab Perimeterഀ 90 ftഀ Perimeterഀ 4 ftഀ Perimeterഀ 2 inഀ Insulation Length:ഀ Insulation Depth:ഀ Insulationഀ Thickness:ഀ 2ഀ Tube Spacing:ഀ 10 inഀ High Heatingഀ 0 ftഀ lntens1 Area:ഀ Aഀ 1st Layerഀ 0.75 inഀ Conductivity:ഀ Btu/h-ftഀ 1.07ഀ *ഀ Thickness:ഀ Fഀ Zone 6 (Snowmelt) [!M" RadiantPEXjഀ Min Tube Len th:ഀ 20 ftഀ supply Waterഀ 108 Fഀ Tempiഀ Thickness Belowഀ 2 inഀ Tube:ഀ Delta T: {30ഀ * Please verify the indicated Itemsഀ accuracyഀ SM 6- ROOF #2ഀ 0ഀ DAYTON SM.rad Copyright(c) Watts Radiant Page 4ഀ Radiant Works 2002.07 Zone List 06-13-2007ഀ Project Informationഀ Project Name: DAYTON RESIDENCEഀ Project Number: Project Quote:ഀ Designed For: KAIBAB PLUMBINGഀ Phone Number:ഀ Fax Number:ഀ Contact Informationഀ Designed By. JAKE FEARഀ Company Name: FERGUSONഀ Phone Number. 303.320.4833ഀ Fax Number: 303.355.0408ഀ Notes:ഀ ALL DIMENSIONS PER PLANS, VERIFY.ഀ ALL FLOOR COVERINGS PER PLANS/CONTRACTOR. VERIFY. ANY CHANGES TOഀ COVERINGS WILL VOID DESIGN AND HEAT LOSS. NOTIFY FEI OF CHANGES ASAP.ഀ ALL SLAB ASSUMED TO HAVE ATLEAT.5" INSULATION.ഀ ALL WALLS ASSUMED R19.ഀ v ~ഀ ALL CEILINGS ASSUMED R-54ഀ Zone 01 (Slab Application)ഀ Rnnm ~narifiratinncഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ Finഀ inഀ 11Aഀ Btu/hഀ to/hഀ GARAGEഀ 18ഀ 639ഀ -ഀ -ഀ 30.7ഀ 19,586ഀ 24,893ഀ Supply Delta Tഀ Fluid [°F] [°F]ഀ Zone Sഀ GPM ~Headഀ ln]ഀ Radiantഀ Panelഀ Loadഀ Typeഀ Tube No. ofഀ Length [ft] Circuitsഀ 2.4ഀ Pump Specs RRadiant Panel Load are calculated on the sm:ഀ Required Heat or Radiant Capacity back and edge losses)ഀ 1/2"ഀ RadiantPEഀ Xഀ ofഀ 2ഀ Zone 02 (Thin Slab Applicationഀ Room S ecificationsഀ Room Name Primary Primary Banded Banded Heating Required Radiantഀ Spacing Area Spacing Area Intensity Heat Capacityഀ rrsa.. it. am Mfgdhl rBtu hiഀ 12ഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 1ഀ Radiant Works 2002.07 Zone Listഀ 7nna -Rnanifinniinnsഀ 06-13-2007ഀ Supplyഀ Delta Tഀ tഀ Rഀ Productഀ Fluid [°F]ഀ [°F]ഀ 7:ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ [ഀ 7ഀ Loadഀ Btuthഀ 120ഀ 20ഀ 1.1ഀ 2.2ഀ 11,170ഀ 1/2"ഀ 175ഀ .2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 03 (Thin Slab Application)ഀ Rnnm .Rnpc-ifirationsഀ Room Nameഀ Primaryഀ Primaryഀ ~Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ capacityഀ [in]ഀ [inഀ [in]ഀ [inഀ Btu/h ft2lഀ tu/hഀ Btu/hഀ BUNK ROOMഀ 12ഀ 171ഀ ഀ ഀ 12.8ഀ 2,181ഀ 3,926ഀ BUNKഀ 12ഀ 39ഀ -ഀ -ഀ 9.3ഀ 364ഀ 1,564ഀ BATHROOMഀ Zone S ecificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ n i tഀ RPഀ Pഀ Tubeഀ No. ofഀ Fluid [°F7ഀ CF]ഀ aഀ Typeഀ th [ft]ഀ Lengഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.4ഀ 1.5ഀ 3,582ഀ 1/2°ഀ 250ഀ 1ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 04 (Thin Slab Application)ഀ Rnnm GnPr-ifir gfinnsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ capacityഀ inഀ inഀ [Btulhഀ Btu/hഀ [Btu/hlഀ BEDROOM #4ഀ 12ഀ 166ഀ -ഀ -ഀ 12.9ഀ 2,149ഀ 4,001ഀ BATHROOM #4ഀ 12ഀ 38ഀ ഀ -ഀ 9.4ഀ 358ഀ 1,528ഀ Zone Snec cationsഀ supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ [Btulhഀ 120ഀ 20ഀ 0.3ഀ 1.3ഀ 3,495ഀ 1/2"ഀ 225ഀ 1ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are cair-watua un u+rs sinciple, v,ഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 2ഀ Radiant Works 2002.07 Zone List 06-13-2007ഀ 7nno Cnar-ifiratinncഀ Supply -ഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ (°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btulhഀ 120ഀ 20ഀ 0.5ഀ 0.4ഀ 4,829ഀ 112"ഀ 150ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs cc mauiant rw 112 LVdu 421vഀ Required Heat or Radiant Capacity back and edge fosses)ഀ Zone 08 (Thin Slab Application)ഀ Room Nameഀ Primaryഀ Primaryഀ vBanded!ഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ nഀ mഀ Btu/h fthഀ Btu/hഀ tu/hഀ BEDROOM #2ഀ 12ഀ 188ഀ -ഀ -ഀ 17.0ഀ 3,190ഀ 4,513ഀ BATHROOM #2ഀ 12ഀ 50ഀ -ഀ -ഀ 8.7ഀ 436ഀ 2,000ഀ 7....e Qnenifvn~~inneഀ Supplyഀ Delta Tഀ GPMഀ wwHeadഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.5ഀ 0.5ഀ 4,845ഀ 1/2"ഀ 150ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Mawarn rurirn Luau a.a.,o..,.......,.....ഀ Required Heat or Radiant Capacity back and edge fosses)ഀ ഀ Zone 09 (Thin Slab Application)ഀ Room S ecificationsഀ dഀ tinഀ Hഀ Requiredഀ Radiantഀ Room Nameഀ Primaryഀ Spacingഀ nഀ Primaryഀ Areaഀ Bandedഀ Spacingഀ [in]ഀ Bandeഀ Areaഀ [f t2lഀ gഀ eaഀ Intensityഀ Btu/hഀ Heatഀ ni28ഀ Capacityഀ tuihഀ 8 806ഀ ROOM 1ഀ F-9 -ഀ 12ഀ 3,196ഀ Zone Specificationഀ Supply Deity T GPM Head Radiantഀ Fluid [°F] rn [ft] Panelഀ Loadഀ tulhഀ ~n 20 1.0 2.7 10,292ഀ Type Length [ft] I Circuitsഀ RadiantPEഀ Pump specs & Radiant Panel Load are caicuiated on the smaner viഀ Required Heat or Radiant Capacity back and edge losses)ഀ DAYTON RES.rad Copyright(c) Watts Radiantഀ Page 4ഀ Radiant Works 2002.07 . Zone Listഀ Required Heat or Radiant Capacity back and edge losses)ഀ 06-13-2007ഀ Zone 06 (Thin Slab Application)ഀ Rnnm Rnc-cificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ an]ഀ [ft2lഀ Btu/h ft2lഀ tu/hഀ [Btu/ഀ ROD`S ROOMഀ 12ഀ 91ഀ -ഀ -ഀ 21.5ഀ 1,953ഀ 2,103ഀ 7r-.n= Cncreifinotinncഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid rF]ഀ rF]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.2ഀ 0.3ഀ 2,473ഀ 112"ഀ 100ഀ 1ഀ RadiantPEഀ •ഀ Xഀ _Lഀ Pump tipecs & Kamant Yane1 Luau w t; t:aiuatatau v,, u isഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 06 (Thin Slab Application)ഀ D,,.,r" Cncrifir-z%nnQഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ On]ഀ inഀ 1ഀ Btu1hഀ [Btu/hlഀ tu/hഀ MEDIA ROOMഀ 12ഀ 490ഀ -ഀ -ഀ 13.5ഀ 16ഀ 8ഀ 6 604ഀ 898ഀ 1ഀ 11,838ഀ 939ഀ 4ഀ KITCHENETTEഀ 12ഀ 113ഀ -ഀ -ഀ .ഀ ,ഀ ,ഀ tഀ dഀ Pഀ ubഀ Noഀ ofഀ Supplyഀ Fluid rF]ഀ Delta Tഀ rF]ഀ GPMഀ Headഀ [ft]ഀ Radiantഀ Panelഀ Loadഀ ucഀ roഀ Typeഀ L~ഀ gthഀ .ഀ uitsഀ Cirഀ cഀ 120ഀ 20ഀ 1.1ഀ 1.4ഀ Btu/hഀ 11,366ഀ Rad antPEഀ Jഀ 22ഀ 3ഀ Xഀ _ ,ഀ _ ...i..~..,tഀ thn emaEtഀ ar ofഀ Pump specs o« r%aumin vQ~ti•ഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 07 (Thin Slab Application)ഀ Roam S ecificationsഀ Room Name Primary Primary Banded Banded Heating Required Radiantഀ Intensity Heat Capacityഀ Spacing Area Spacing Areaഀ rna..n. sm rR+nlh7 ratumഀ 2ഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 3ഀ Radiant Works 2002.07 Zone List 06-13-2007ഀ Zone 10 (Thin Slab Application)ഀ Do-rv% Cnorifir*~tinncഀ Room Nameഀ Primaryഀ Primaryഀ Banded Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacing Areaഀ Intensityഀ Heatഀ Capacityഀ [in]ഀ Inഀ Stulhഀ tulhഀ tuihഀ MASTERഀ 6ഀ 582ഀ - -ഀ 33.2ഀ 19,310ഀ 15,842ഀ BEDROOMഀ 1110 M19WOU [wV1110 1110Y JcMuac cwunmo.Yഀ 7nnc Qnianifinnfinmഀ Supplyഀ Delta Tഀ GPMഀ - -ഀ Headഀ -ഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 1.8ഀ 1.4ഀ 17,553ഀ 1/2"ഀ 250ഀ 5ഀ RadiantPEഀ Xഀ Pump specs & Kaoiant ranee Loaa are caloulaMU vl i U IV W 1101101 viഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 11 (Thin Slab Application)ഀ Room S ecabonsഀ Room Name Primary Primary Banded Banded Heating Required Radiantഀ Spacing Area Spacing Area intensity Heat_ Capacityഀ 72 -----T-28.4 2,048 2,914ഀ BATHROOMഀ 7nnra Anar_'ifiratinn-Qഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.2ഀ 0.3ഀ 2,187ഀ 1/2"ഀ 100ഀ 1ഀ RadiantPEഀ Xഀ Pump specs & Kamant vanel Laaa are c:U1UU1dU!U U11 tim; ail,auGi viഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 12 (Thin Slab Application)ഀ Rnnm gnarifiratinnsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Banded'ഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ On]ഀ [in]ഀ Mഀ Btu/h Tഀ tu/hഀ Btu/hഀ MASTER CLOSETഀ 12ഀ 209ഀ -ഀ -ഀ 18.1ഀ 3,782ഀ 4,638ഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 5ഀ Radiant Works 2002.07 Zone Listഀ 7nna Sner-ificafinnsഀ 06-13-2007ഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.8ഀ 1.5ഀ 8,174ഀ 1/2"ഀ 200ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smauer orഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 13 (Thin Slab Application)ഀ Rnnm Snecificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ mഀ mഀ tulhഀ tufhഀ LAUNDRY/HALLWഀ 12ഀ 216ഀ -ഀ -ഀ 20.9ഀ 4,522ഀ 7,537ഀ AYഀ POWDER ROOMഀ 12ഀ 28ഀ -ഀ -ഀ 10.8ഀ 302ഀ 1,139ഀ 7nne Specificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ . Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 0.5ഀ 0.5ഀ 5,159ഀ 112"ഀ 150ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smauer oTഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 14 (Thin Slab Application)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ nഀ ft Bഀ tuth ft2jഀ tulhഀ Btu/hഀ KITCHENഀ 12ഀ 166ഀ ഀ ഀ 27.3ഀ 4,536ഀ 5.874ഀ Zone S ecificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ . Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ tu/hഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 6ഀ Radiant Works 2002.07 Zone Listഀ 06-13-2007ഀ 120ഀ 20ഀ 0.5ഀ 0.5ഀ 4,980ഀ 1/2" 150ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel t.oao are caicuiateo on Lne s~na~se~ ~sഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 15 (Thin Slab Application)ഀ Rnnm Snacifcationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ [in]ഀ [ft2lഀ Btu/hഀ [Btu/hiഀ Btu/hഀ OFFICEഀ , 12ഀ 101ഀ ഀ ഀ 24.1ഀ 2,431ഀ 3,382ഀ Zone S cationsഀ Suppyഀ Dena Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ rF]ഀ [ft)ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btuthഀ 120ഀ 20ഀ 0.3ഀ 0.4ഀ 2,589ഀ 112"ഀ 125ഀ 1ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are ca►cuiateo on me smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 16 (Thin Slab Application)ഀ Rnnm Rnacificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ nഀ nഀ Btum ffl_ഀ Btu/hഀ Btuthഀ LIVING ROOMഀ 12ഀ 787ഀ -ഀ -ഀ 29.4ഀ 23,112ഀ 28,714ഀ Zone Soecificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ rF]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 2.5ഀ 3.7ഀ 24,563ഀ 1/2"ഀ 250ഀ 4ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 17 (Thin Slab Application)ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ mഀ fin]ഀ Iftlഀ Btu/hഀ Btu/hഀ tu/hഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 7ഀ Radiant Works 2002.07 Zone Listഀ rooms mayഀ 7nna Gnpe..ifif-ationsഀ 0613-2007ഀ Supplyഀ Delta Tഀ GPMഀ yvHeadഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ [°F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ Btu/hഀ 120ഀ 20ഀ 1.2ഀ 2.4ഀ 11,896ഀ 1/2"ഀ 175ഀ 2ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Zone 18 (Thin Slab Application) -ഀ Room Specificationsഀ Room Nameഀ Primaryഀ Primaryഀ Bandedഀ Bandedഀ Heatingഀ Requiredഀ Radiantഀ Spacingഀ Areaഀ Spacingഀ Areaഀ Intensityഀ Heatഀ Capacityഀ inഀ [in]ഀ M9ഀ Btu/h ftlഀ Btu/hഀ tu/hഀ LOFTഀ 9ഀ 367ഀ -ഀ -ഀ 25.6ഀ 9,400ഀ 9,400ഀ Zone Specificationsഀ Supplyഀ Delta Tഀ GPMഀ Headഀ Radiantഀ Productഀ Tubeഀ No. ofഀ Fluid [°F]ഀ ["F]ഀ [ft]ഀ Panelഀ Typeഀ Length [ft]ഀ Circuitsഀ Loadഀ [Btu/hlഀ 120ഀ 20ഀ 1.0ഀ 0.9ഀ 10,246ഀ 1/2"ഀ 175ഀ 3ഀ RadiantPEഀ Xഀ Pump Specs & Radiant Panel Load are calculated on the smaller ofഀ Required Heat or Radiant Capacity back and edge losses)ഀ Thermostat should be located in the room in which the radiant capacity is closest to the requiredഀ heat.ഀ Project Totalsഀ Radiant System Pumping Specs: 16.3 GPM at 10.3 feet of head. (excluding Supply & Returnഀ piping.)ഀ Radiant System Boiler Load: 162959 Btu/h (excluding Supply & Return piping losses and Aux. Heat,ഀ if required)ഀ 7500' of 1/2* RadiantPEXഀ * Report not valid unless Assumption Report has been verified.ഀ DAYTON RES.rad Copyright(c) Watts Radiant Page 8ഀ cഀ xഀ aഀ nഀ bഀ bഀ mഀ F+ഀ Cഀ xഀ mഀ P.ഀ nഀ Oഀ bഀ O'ഀ aഀ bഀ wഀ mഀ Nഀ mഀ Cf~1 P_ഀ m 20 ~ Z aഀ Nഀ °a Milഀ mഀ Elmഀ pഀ -iഀ aഀ K-0ഀ Oil!ഀ ~a oഀ Nഀ Oഀ Oഀ Jഀ Oഀ Nഀ Oഀ Nഀ Oഀ vഀ Oഀ 7ഀ "Oഀ Oഀ Rഀ Fഀ Mഀ pNഀ 4ഀ Jഀ S,ഀ Sഀ dഀ Oഀ zഀ aഀ nഀ Oഀ K3ഀ F~ഀ aഀ bഀ ~D1ഀ 6ഀ Wഀ toഀ ~xyഀ lam!ഀ mഀ CLഀ Aഀ 0ഀ Ctഀ aഀ ►dഀ mഀ a6ഀ Zഀ ~Oഀ Oഀ wഀ Oഀ Oഀ Oഀ 3ഀ Iഀ Cഀ aCഀ Oഀ 0ഀ sഀ Cfഀ Jഀ Gഀ bഀ 0ഀ dഀ 0ഀ 0ഀ Nഀ Qഀ Oഀ Vഀ O.ഀ pഀ Oഀ 7ഀ Nഀ Dഀ Nഀ Oഀ vഀ rഀ Gഀ bഀ 0ഀ dഀ 0ഀ tv us J!ഀ mill I<Lഀ 3ഀ 1!°i ~i 3N Nഀ N IVA mrt tagഀ •fഀ torഀ R' ~ Vഀ 3 Hഀ Q. c ic N o o aഀ 5 Jഀ uഀ r I_ഀ T• a0 ~Q ° O ~i1y~ N Wഀ 0 -cഀ I WAഀ o, D tg.ഀ S a $ e(Aഀ oഀ oഀ m s m m 3 Jഀ aഀ o W ~ A ~ N Wഀ a ~ഀ eഀ 0ഀ » x milliഀ aഀ eum 5 qഀ aഀ ligഀ 3ഀ in mഀ I oഀ lieഀ o~ഀ ~ cW ado ~ ~ j nag g eഀ oഀ m ~ഀ vഀ 3ഀ $ u m 8 ar pNഀ c I E 3 n $ഀ D $ Nഀ m Sഀ a ry~ഀ a C)ഀ lowഀ bഀ mഀ Mഀ C < 3 ~ഀ O O~~p e Cഀ b 1 101ഀ p' WiW • J Nഀ 00ഀ sഀ 1ഀ Oഀ Nഀ Oഀ wഀ iഀ 21ഀ -Wഀ f$ഀ wഀ mpmഀ Olഀ hഀ oഀ "n oഀ "yഀ trഀ Iഀ Cഀ Nഀ QQഀ aഀ Tഀ Nഀ aഀ oഀ tഀ gഀ ollഀ ഀ Qഀ Cഀ pഀ Icഀ oഀ 3.ഀ 1 iഀ nഀ Zഀ y~ഀ Tഀ Iഀ °ഀ Aഀ Siഀ Sഀ S'ഀ 40ഀ wഀ bഀ ilഀ aഀ ~ •ഀ fS'ഀ w doഀ ~ °ഀ fl!ഀ mഀ bഀ oഀ ~ഀ Nഀ -aഀ llഀ ~ഀ .'Pഀ ~ഀ Nഀ o.ഀ 0ഀ mഀ 7ഀ Iഀ sgഀ Nഀ ~ഀ r~ഀ 0ഀ 1Sഀ rഀ ,ഀ pഀ 3ഀ $ഀ cmഀ Nഀ Nഀ Oഀ ~ഀ Oഀ 'dഀ • O j Nഀ ^Vl m O rഀ W fഀ a SG p,ഀ 0ഀ n -aഀ bഀ 'Pig a mഀ 00 p r, O W 3 O 0000 j.,ഀ OO,, ~ 5xഀ Zഀ pigഀ ~~rr g o n ,oഀ ~ p aഀ y 10 0 IT I wഀ z ~ഀ W u ml T a y oഀ A "nഀ s gഀ 177 , ~ ..C~ n 6 ^J OCഀ dഀ A o a o G o 0 IQഀ o mഀ oഀ lഀ fillഀ Iഀ I'd We 13ഀ a mഀ Tഀ .trഀ ~ഀ ~ yഀ ~ഀ Sഀ iഀ sഀ sഀ mഀ ~ഀ ~Jഀ pഀ Vഀ vഀ ~ഀ ~ഀ aഀ ~ഀ ഀ ~yഀ ~ഀ pഀ sഀ yIഀ 0ഀ aഀ Nഀ gഀ sഀ ഀ 3ഀ Sഀ nഀ yഀ Tഀ ~ഀ Nഀ ~ഀ Oഀ Nഀ ഀ yഀ mഀ Tഀ ♦ഀ }ഀ Oഀ ഀ Nqഀ Oഀ ~ഀ 01ഀ ~ഀ ►dഀ oqഀ cഀ }ഀ yഀ Wഀ ~ഀ 3ഀ aഀ g' 60 ~iഀ Oഀ wഀ oഀ ~ aഀ ~ aഀ wഀ yഀ roഀ Tഀ ~ഀ •Oഀ ~ഀ iഀ $ഀ 3ഀ ~ഀ ►yഀ ~ഀ y,ഀ a oഀ N ~ഀ m ~ഀ ~ഀ Oഀ Oഀ NOR Of i f it killഀ -n -mഀ b, eഀ aഀ 0ഀ e O Cഀ aഀ oo~ P o 0 0-~ wഀ VIA.ഀ i v~ഀ F q ~7ഀ 8ഀ a "n is CAഀ W Sgt y Nഀ Oഀ O Jഀ o mഀ Z- > "ITഀ rt -i Ell Oഀ 1 fill bpdഀ pQ 1ഀ 4ഀ >pro 0ഀ S, •fih Npഀ Sഀ O~1 ~ ~ഀ R s 9 # iഀ zഀ ^ ° co toഀ m m m J °ഀ o a $ 4 0ഀ I "n _0ഀ aഀ ? aഀ lay' Q • ~ q, If Iഀ Q'ഀ ov 4-Aഀ aഀ m oഀ 31ഀ WWI iഀ 9 aഀ allഀ 9ഀ C7ഀ n ~ഀ m oഀ 6ഀ IRISH 1ഀ aഀ 0ഀ N ~ Vഀ ODഀ iഀ • ~ ~ mgr O aഀ aq cowlഀ m a D fNഀ OOഀ ~J in m ~ nഀ b ~ o~ oഀ m ~ oഀ LLLI -1 --1ഀ L$ it `7ഀ m ~ oഀ t3. Nഀ nഀ dഀ Tഀ o eഀ aഀ o + y~ aഀ QC 1ഀ 4 pഀ a Oഀ N ~ഀ Oഀ Page I of 1ഀ Hഀ Irn)ഀ uഀ UPഀ 60 Hzഀ 10-ഀ 7-ഀ 6-ഀ 5-ഀ 4-ഀ 2-ഀ 0 15 20 30 40 60 BO 100 150ഀ 0 (us GPM)ഀ 3 s 5 6 7 S 9 10 20 wഀ Q Im31hlഀ P-Dഀ UP 53-~5ഀ gam, pie R~ ,~iMPsഀ ~p 43 -hDഀ 40ഀ 30ഀ 20ഀ 15ഀ A3-110__..ഀ 53-4roഀ 53.45'iഀ 1(ഀ Page 1 of 1ഀ H Hഀ fml tttlഀ 2060ഀ 50ഀ 40ഀ ioഀ g 30ഀ 6ഀ 6 20ഀ 5ഀ 15ഀ 4-ഀ 2-ഀ UPSഀ 60 Hzഀ I 40.240ഀ 32•x601 44160 W160 W-160ഀ 7~-5i3ഀ 40.80:2 Saഀ 32.80 40 90/4 BO-80ഀ 3240 40-40 ~SO 40 80-40 10() 40ഀ 0 15 20 30 40 W 80 100 150 2ഀ 0 [US 00 ~'P 3Wഀ 3 4 5 6 7 8 0 10 20 30 40 50 60ഀ Q (m'fh]ഀ P-3ഀ i%~iMnRV GRc qOA~uPഀ Series UP Circulators - closed systemsഀ Heating & Air conditioningഀ homeഀ ' Backഀ Page I of 1ഀ Prinഀ Series UP Circulators - closed systemsഀ Industries highest quality and quietest operating HIGHLIGHTSഀ heating circulators SuperBrute._a new standardഀ < Rotate - > Play animation • Unmatched flexibility - 3 speed m,ഀ technology for easy adaptability.ഀ • Highest reliability - patented ED utഀ unmatched starting torque.ഀ • Top performance - removable,ഀ integrated check valve doesn't inhibi-ഀ water flow.ഀ > Where to purchaseഀ click left or right arrow to rotate each frameഀ FEATURESഀ • Built-in motor protection for long lifeഀ • Multiple accessories for a variety of applicationsഀ • Whisper-quiet operation for sound sensitiveഀ installationsഀ PERFORMANCEഀ Performance chart is shown for reference only.ഀ Download the submittal data sheet for exact performance.ഀ CLOSED SYSTEMS 60HZഀ APPLICATIONSഀ • Hydronic heatingഀ • Fan coil heatingഀ • Solar heatingഀ • Radiant heating systemsഀ 35 O UP26-1'6Fഀ UP26-99Fഀ 30 UP 43- 75 F:` UP 50- 75 Fഀ UP 26-96 Fഀ 25 UP 26- 64 Fഀ UP15-42FBM EDഀ 20 UPS 15 - SSFIFC (Spd 3)ഀ UP 15-10 RIFRഀ 15 UP 15-100Fഀ T UP26-120Uഀ 34ഀ -ഀ Yഀ 0 5 10 15 20 25 30 35 40 45 50ഀ Flow (gpm)ഀ TECHNICAL DATA GRUNDFOS SERIES UPഀ UPS 15-58FC/FRC SUPERBRUTEഀ 20ഀ Iഀ Without Check Valveഀ 18ഀ rഀ ♦ഀ ഀ ഀ ഀ With Check Valveഀ 16ഀ ഀ ♦ഀ -ഀ Iഀ 12ഀ ഀ - -ഀ vഀ 10ഀ -ഀ -ഀ - ! ♦ഀ ഀ j -ഀ Iഀ 6ഀ -4-ഀ `ഀ ♦ I Iഀ 2 -ഀ -ഀ =ഀ 1` - -ഀ ഀ -ഀ 0ഀ 0ഀ 2 4ഀ 6ഀ 8 10ഀ 12ഀ 14 16 18ഀ Flow (GPM)ഀ Flow range:ഀ 0 - 17.5 U.S. GPMഀ Head range:ഀ 0 - 19 FEETഀ Motors:ഀ 2 Pole, Single Phaseഀ Maximum fluid temperature:ഀ 230°F (110°C)ഀ Min. fluid temperature:ഀ 36°F (2°C)ഀ Maximum working pressure:ഀ 145 PSIഀ UPS15-58FC/FRCഀ AMPSഀ WATTSഀ HPഀ CAPACITORഀ S pd. 3ഀ 115V Sd. 2ഀ 0.75ഀ 0.66ഀ - 87ഀ 80ഀ 1/25ഀ 1125ഀ lOmF/180Vഀ lOmF/180Vഀ L Spd. lഀ 0.55 xഀ _60ഀ 1/25ഀ lOmF/180Vഀ Eഀ D Fഀ Model Typeഀ Aഀ Bഀ Cഀ Dഀ Eഀ Fഀ Connection Type and Sizeഀ Shippingഀ Wt. (Lb.)ഀ UPS15-58FC/FRCഀ 61/2ഀ 51/4ഀ 4ഀ 4 3/16ഀ 3ഀ 3 5/32ഀ GF 15/26 Flange - (2) 1/2" Dia. Bolt Holesഀ 71/4ഀ 34 ~RUNO~os•Nഀ GENERAL DATA GRUNDFOS SERIES UPഀ UPS 26-99FC/BFC SUPERBRUTEഀ 30ഀ Without Check Valveഀ ഀ 25 - ` With Check Valveഀ -ഀ 20ഀ ~ 15 i - i ~ഀ i `ഀ - -ഀ 10ഀ ♦ ♦ *44.ഀ 5 ~ഀ 0ഀ 15 20 25 30 35ഀ 10ഀ D 5ഀ Flow (GPM)ഀ Flow range: 0 - 34 U.S. GPMഀ Head range: 0 - 30 FEETഀ Motors: 2 Pole, Single Phaseഀ Maximum fluid temperature: 230°F (110°C)ഀ Min. fluid temperature: 36°F (2°C)ഀ Maximum working pressure: 145 PSIഀ MODELഀ VOLTSഀ AMPSഀ WATTSഀ HPഀ CAPACITORഀ -ഀ ഀ Iഀ Spd. 3ഀ 1.8ഀ 197ഀ 1/6 jഀ 20mF/180Vഀ Iഀ 115Vഀ Spd_2ഀ -ഀ 1.5ഀ 179ഀ 1/6ഀ 20mF/180V~ഀ Spd. 1ഀ 1.3ഀ _ 150ഀ 1/6ഀ 20mF/180V Iഀ -ഀ _ഀ 230Vഀ Spd.3ഀ Spd.2ഀ 0.9ഀ 0.8ഀ 196ഀ 179ഀ 1/6ഀ 1/6ഀ 5mF/400Vഀ 1ഀ 5mF/400Vഀ _ഀ Sid 1ഀ _ഀ 07 _ഀ 150ഀ 1/6 _ഀ I -5mF/400V---ഀ Iഀ lEഀ D Fഀ FFഀ - -ഀ Iഀ Model Type i A Bഀ -ഀ ഀ (ഀ Cഀ ഀ D _ Eഀ _Fഀ _Connection Type and Sizeഀ "ഀ Approximateഀ Shipping Wt.ഀ - (ibs)ഀ ~UPS25-99FC/BFC61/2 1ഀ 6ഀ 47/8ഀ 3 1/2 3 7/16ഀ 3 5/32ഀ Dia. Bolt Holesഀ GF 15/26 Flange (2) 1/2ഀ 10.3ഀ GRUN~FOS`:;ഀ 44ഀ GENERAL DATA GRUNDFOS SERIES UPഀ UPS 43-44FC/BFC SUPERBRUTEഀ 16ഀ 14ഀ 12ഀ 10ഀ 8ഀ 0ഀ 6ഀ 4ഀ 2ഀ 0ഀ 0ഀ 10ഀ 20 30 40ഀ 50 60ഀ Flow (GPM)ഀ Flow range: 0 - 64 U.S. GPMഀ Head range: 0 - 14 FEETഀ Motors: 2 Pole, Single Phaseഀ Maximum fluid temperature: 230°F (110°C)ഀ Min. fluid temperature: 32°F (0°C)ഀ Maximum working pressure: 145 PSIഀ UPS43-WFGBFCCഀ S 3ഀ AMPSഀ 1.8ഀ WATTSഀ 203ഀ HP -ഀ 1/6ഀ CAPACITORഀ 20mF/180Vഀ 11SVഀ 5 .2ഀ 1.7ഀ 189ഀ 1/6ഀ 20mF/180Vഀ 5 .1ഀ 1.4ഀ 157ഀ 1/6_ഀ 20mF/180Vഀ Spd 3ഀ 0.9ഀ 203ഀ 1/6ഀ 5mF/400Vഀ 230Vഀ Spd. 2~ഀ - 0.8ഀ 190ഀ 1/6ഀ 5mF/400Vഀ Spd.1ഀ 0.7ഀ 157ഀ 1/6ഀ 5mF/400Vഀ Eഀ D Iഀ I L41 7ഀ iഀ rox'unateഀ Aഀ Iഀ ppഀ Shimft Wtഀ ModelTypeഀ Aഀ B I _C_ _ഀ D ~ഀ - E-ഀ I. _ Connection Type and Sizeഀ "ഀ -ഀ UP543-44FUBFCഀ 8112ഀ 1ഀ b11/ഀ 16 51/8ഀ -ഀ 43/4 I,ഀ 3 3/161ഀ Dia. Bolt Holes I 13.6ഀ 1 GF 40/43 Flange - (2) 1/2ഀ 3 7/16ഀ Without Check Valveഀ With Check Valveഀ ;ഀ iഀ ~ഀ Iഀ GRUNOFOS"V% 49ഀ Technical Dataഀ 'ഀ 720ഀ lഀ 724 Bഀ vesഀ 4-Way Mixing Vaഀ rassഀ -ഀ Literatureഀ - D720ഀ Acceptable Fluid Media - Chilled and hot water with antifreezeഀ Maximum Operating Pressureഀ - 146 psi (10 bar)ഀ (max. 600/6), consisting of ethylene glycol,ഀ Operating Temperature Rangeഀ - -20 to 248°F (-28 to 1201C)ഀ propylene glycol, methanol, ethanol, iso-ഀ propanol, and anticorrosive compounds.ഀ Valve Body and Vaneഀ - CW 617N - EN 12165 Brassഀ Shaft Sealഀ - EPDM Perioxide "O" ringഀ Not for use with fluids that contain mineralഀ Main Sealഀ - EPDM Perioxide "O" ringഀ oil or chlorinated pool water.ഀ uI.ഀ 1.5ഀ 3-ഀ 1ഀ s2ഀ p aഀ 1 0.5ഀ 0 0ഀ Wഀ Typeഀ 720ഀ ഀ Sizeഀ 3/4"ഀ CV Valuഀ 7ഀ Dimensionഀ eഀ 3" (76 mm)ഀ Dimensionഀ 3" (76 mm)ഀ Packaged Weightഀ 2.2 lbs (980 g)ഀ 721ഀ 1"ഀ 14ഀ 3" (76 mm)ഀ 3" (76 mm)ഀ 1.8 Ibs (800 g)ഀ 722ഀ 1-1/4"ഀ 21ഀ 3-1/4" (82 mm)ഀ 3-1/4" (82 mm)ഀ 2.2 ibs (980 g)ഀ 723ഀ 1-1/2"ഀ 32ഀ 4-3/8"(111 mm)ഀ 4-3/8" (111 mm)ഀ 7.3lbs (3320 g)ഀ 724ഀ 2"ഀ 51ഀ 4-5/8" (119 mm)ഀ 4-5/8" (119 mm)ഀ 5.8 ibs (2640 g)ഀ Valve Performance 720, 721ഀ m'fiഀ 0 1 2 3 4ഀ j 7201 721ഀ iഀ iഀ NoLaiഀ Operatingഀ Range Iഀ 1ഀ 3-ഀ 0.8ഀ ~ wഀ 0.6 L =2-ഀ 0 0ഀ 0.4 1ഀ 0.2ഀ 0 0ഀ 0 2 4 6 8 10 12 14 16 18 20ഀ US Gal/minഀ 0 3 6 9 12 15 1Eഀ 1.5 -ഀ 722 723 i 724.ഀ n m3/hഀ 1 Normal ;ഀ Operatingഀ a Range j {ഀ 0.5-ഀ 1ഀ 0.8ഀ -oഀ 0.6ഀ 0.4 Eഀ 0.2ഀ 0ഀ 0 10 20 30 40 50 60 70 80ഀ US Gal/minഀ Limited Warranty and Product Return Or.ഀ Limited Warranty The liability of tekmar under this warranty is limited. Theഀ Purchaser, by taking receipt of any tekmar product ("Product'] acknowl-ഀ edges the terms of the Limited Warranty in effect at the time of such Productഀ sale and acknowledges that it has read and understands same.ഀ The tekmar Limited Warranty to the Purchaser on the Products sold hereunderഀ Is a manufacturer's pass-through warranty which the Purchaser is authorizedഀ to pass through to its customers. Under the Limited Warranty, each tekmarഀ Product is warranted against defects in workmanship and materials if the Prod-ഀ uct Is installed and used in compliance with tekmar's instructions, ordinaryഀ wear and tear excepted. The pass-through warranty period is for a period ofഀ twenty-four (24) months from the production date If the Product Is not installedഀ during that period, or twelve (12) months from the documented date of installa-ഀ tion 0 Installed within twenty-four (24) months from the production date.ഀ The liability of tekmar under the Limited Warranty shall be limited to, at tekmar'sഀ sole discretion: the cost of parts and labor provided by tekmar to repair defects inഀ materials and/or workmanship of the defective product; or to the exchange of theഀ defective product for a warranty replacement product; or to the granting of creditഀ limited to the original cost of the defective product, and such repair, exchange orഀ credit shall be the sole remedy available from tekmar, and, without limiting theഀ foregoing in any way, tekmar is not responsible, in contract, tort or strict prod-ഀ uct liability, for any other losses, costs, expenses, inconveniences, or damages,ഀ whether direct, indirect, special, secondary, incidental or consequential, arisingഀ from ownership or use of the product, or from defects in workmanship or materials,ഀ including any liability for fundamental breach of contract.ഀ The pass-through Limited Warranty applies only to those defective Productsഀ returned to tekmar during the warranty period. This Limited Warranty does notഀ cover the cost of the parts or labor to remove or transport the defective Product, orഀ to reinstall the repaired or replacement Product, all such costs and expenses beingഀ subject to Purchaser's agreement and warranty with its customers.ഀ Any representations or warranties about the Products made by Purchaser to itsഀ customers which are different from or in excess of the tekmar Limited Warranty areഀ Valve Performance 722, 723, 724ഀ the Purchaser's sole responsibility and obligation. Purchaser shall indemnify andഀ hold tekmar harmless from and against any and all claims, liabilities and damagesഀ of any kind or nature which arise out of or are related to any such representationsഀ or warranties by Purchaser to its customers.ഀ The pass-through Limited Warranty does not apply if the returned Product hasഀ been damaged by negligence by persons other than tekmar, accident, fire, Actഀ of God, abuse or misuse; or has been damaged by modifications, alterations orഀ attachments made subsequent to purchase which have not been authorized byഀ tekmar; or if the Product was not installed in compliance with tekmar's instructionsഀ and/or the local codes and ordinances; or if due to defective installation of theഀ Product; or if the Product was not used in compliance with tekmar's instructions.ഀ THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS ORഀ IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTU-ഀ ALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OFഀ MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABIL-ഀ ITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANYഀ RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-ഀ VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEG-ഀ ISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRAC-ഀ TUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYONDഀ TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENTഀ THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.ഀ Product Warranty Return Procedure All Products that are believed to haveഀ defects in workmanship or materials must be returned, together with a writtenഀ description of the defect, to the tekmar Representative assigned to the territory inഀ which such Product is located. If tekmar receives an inquiry from someone otherഀ than a tekmar Representative, including an inquiry from Purchaser (if not a tekmarഀ Representative) or Purchaser's customers, regarding a potential warranty claim,ഀ tekmar's sole obligation shall be to provide the address and other contact informa-ഀ tion regarding the appropriate Representative.ഀ ® tekmar Control Systems Ltd., Canadaഀ telmr tekmar Control Systems, Inc., U.S.A.ഀ Control Systems Head Office: 5100 Silver Star Roadഀ Vernon, B.C. Canada V1B 3K4ഀ (250) 545-7749 Fax. (250) 545-0650ഀ Web Site: www.tekmarcontrols.comഀ Product design, software and literature are Copyright @ 2007 by: 2 of 2 All specifications are subject to change without notice. 4%r-ഀ 'tekmar Control Systems ltd. and tekmar Control Systems. Inc. Printed in Canada. D720 - 05/07.ഀ D720ഀ 05/07ഀ The 4-Way Brass Mixing Valves 720, 721, 722, 723, and 724 are used to mix supply water fromഀ a heat source with water returning from a system. They are designed for use in either closedഀ loop or open loop hydronic systems. All valves have standard female NPT threads. The valveഀ provides a maximum leak through rate of 1 % to allow for water expansion during temperatureഀ changes. The valve position can be manually set using the handle. An Actuating Motor 741 canഀ be used to automatically operate the valve.ഀ Sequence of Operationഀ When the flap is in the fully closed position,ഀ 100% of the boiler supply water is returnedഀ to the boiler and 100% of the heating systemഀ return water is supplied to the system. Whenഀ the valve flap is in the fully open position,ഀ 100% of the boiler supply water enters theഀ heating system and 100% of the heatingഀ system return water returns to the boiler.ഀ Mixing of the water takes place when the valveഀ flap is in an intermediate position.ഀ Valve in closed position Valve 500/6 position Valve fully openഀ Installation - F `ഀ STEP ONE GETTING READYഀ Check the contents of the package. If any of the items listed below are missing or damaged, please refer to the Limited Warrantyഀ and Product Return Procedure on the back of this brochure and contact your wholesaler or local tekmar representative.ഀ Types 720 - 724 include -One Mixing Valve & One Data Brochure D 720ഀ STEP TWO MOUNTINGഀ Clockwise to Openഀ Counter Clockwise to Openഀ valve to systemഀ Valveഀ to systemഀ Closed 4ഀ Closedഀ Tilഀ Remove the "C" clip from theഀ As delivered, noഀ shaft. Turn over the indicatorഀ Is changes required.ഀ ~"ti rഀ plate in order to reverse theഀ from fromഀ 'ഀ fromഀ fromഀ ilഀ scale. Re-install the indicatorഀ systemഀ boilerഀ systemഀ boഀ erഀ plate, "C" clip and handle.ഀ (components shown below)ഀ ®ഀ to boilerഀ to boilerഀ Replacement Partsഀ The Mixing Valve Handle Kit M3047 contains a replacementഀ manual valve handle, a brass screw, a "C" clip, and a positionഀ indicator plate.ഀ 1 of 2ഀ o :3 5 ~S~ഀ oഀ Oഀ brassഀ screwഀ "C" clipഀ handleഀ indicator plateഀ © 2007 ftIun D 720 - 05/07ഀ Water Heater Specifications A Trion Tubeഀ Nat Watu f 'ഀ C,ഀ Thermostatഀ & Cover Plateഀ Air Ventഀ Cold Waterഀ Inlet 0ഀ Fഀ Eഀ Top Viewഀ Hot Waterഀ Outletഀ Auxiliaryഀ Connectionഀ B<ഀ Reഀ Boileഀ Supplഀ Rear Viewഀ Waterഀ detഀ Modelഀ Smart 20ഀ Smart 30ഀ Smart 40ഀ Smart 50ഀ Smart 60ഀ Smart 80ഀ Smart 100ഀ Smart 120ഀ Capacityഀ Gal.ഀ Domesticഀ 22ഀ 28ഀ 36ഀ 46ഀ 56ഀ 70ഀ 95ഀ 119ഀ Boilerഀ 5ഀ 5ഀ 6ഀ 8ഀ 8ഀ 14ഀ 25ഀ 30ഀ Heating surfaceഀ Sq. Ft.ഀ 11ഀ 13ഀ 16ഀ 20ഀ 24ഀ 29ഀ 36ഀ 40ഀ Boiler head loss at minimum flowഀ Ft.ഀ 3/4ഀ 314ഀ 1ഀ 11/4ഀ 11/2ഀ 2ഀ 2ഀ 21/2ഀ Piping connectionsഀ Inchesഀ Domesticഀ 0ഀ 3/4ഀ 3/4ഀ 3/4ഀ 3/4ഀ 3/4ഀ 11/2ഀ 11/2ഀ 11/2ഀ Boilerഀ 0ഀ 1ഀ 1ഀ 1ഀ 11/4ഀ 11/4ഀ 1 1/2ഀ 1 1/2ഀ 2ഀ Auxiliaryഀ 0ഀ 3/4ഀ 3/4ഀ 3/4ഀ 3/4ഀ 3/4ഀ 11/2ഀ 11/2ഀ 11/2ഀ Dimensionsഀ Inchesഀ Aഀ 32ഀ 38ഀ 46ഀ 57ഀ 66ഀ 61ഀ 78ഀ 72ഀ Bഀ 9ഀ 9ഀ 9ഀ 9ഀ 9ഀ 10ഀ 10ഀ 10ഀ Cഀ 24ഀ 30ഀ 38ഀ 49ഀ 58ഀ 501/2ഀ 501/2ഀ 64ഀ Dഀ 22ഀ 22ഀ 22ഀ 22ഀ 22ഀ 26ഀ 26ഀ 32ഀ Eഀ 14ഀ 14ഀ 14ഀ 14ഀ 14ഀ 101/2ഀ 10 1/2ഀ 101/2ഀ Fഀ 6ഀ 6ഀ 6ഀ 6ഀ 6ഀ 101/2ഀ 10 1/2ഀ 5ഀ Drywell lengthഀ Inchesഀ 14ഀ 25ഀ 29ഀ 37ഀ 47ഀ 47ഀ 51ഀ 51ഀ Empty weightഀ Lbs.ഀ 100ഀ 115ഀ 135ഀ 165ഀ 190ഀ 315ഀ 390ഀ 524ഀ Auxiliaryഀ Performances A TriongleTubsഀ ~t W~~ J trഀ Modelഀ Boiler Heatingഀ Capacity MBHഀ Peak Flowഀ Gal./ 10 min.ഀ 1st Hour Flowഀ Gal./Hourഀ Continuous Flowഀ Gal./Hourഀ Circulatorഀ Min. GPMഀ SMART 20ഀ 70ഀ 35ഀ 110ഀ 95ഀ 5ഀ SMART 30ഀ 76ഀ 40ഀ 125ഀ 100ഀ 5ഀ SMART 40ഀ 106ഀ 50ഀ 170ഀ 140ഀ 7ഀ SMART 50ഀ 121ഀ 65ഀ 200ഀ 160ഀ 8ഀ SMART 60ഀ 243ഀ 100ഀ 370ഀ 325ഀ 16ഀ SMART 80ഀ 285ഀ 120ഀ 435ഀ 380ഀ 18ഀ SMART 100ഀ 337ഀ 150ഀ 525ഀ 450ഀ 25ഀ SMART 120ഀ 420ഀ 190ഀ 650ഀ 560ഀ 28ഀ Conditions: 50° F Domestic Cold Water Inlet Temperatureഀ 140°F Domestic Hot water Outlet Temperatureഀ 200°F Boiler Water Supply Temperatureഀ Modelഀ Boiler Heatingഀ Capacity MBHഀ Peak Flowഀ Gal./10 min.ഀ 1 st Hour Flowഀ Gal./Hourഀ Continuous Flowഀ Gal./Hourഀ Circulatorഀ Min. GPMഀ SMART 20ഀ 95ഀ 50ഀ 195ഀ 175ഀ 6ഀ SMART 30ഀ 115ഀ 60ഀ 235ഀ 210ഀ 8ഀ SMART 40ഀ 130ഀ 70ഀ 270ഀ 240ഀ 9ഀ SMART 50ഀ 180ഀ 95ഀ 370ഀ 330ഀ 12ഀ SMART 60ഀ 320ഀ 145ഀ 635ഀ 590ഀ 21ഀ SMART 80ഀ 340ഀ 165ഀ 690ഀ 630ഀ 24ഀ SMART 100ഀ 380ഀ 185ഀ 775ഀ 700ഀ 26ഀ SMART 120ഀ 445ഀ 235ഀ 915ഀ 820ഀ 30ഀ Conditions: 50° F Domestic Cold Water Inlet Temperatureഀ 115°F Domestic Hot water Outlet Temperatureഀ 200°F Boiler Water Supply Temperatureഀ uioo•esnenienal tpRpaJ'ALM ► OOZL"698"666 •OLOL"696"666 .plഀ 089Z6 v3'lswo.4 elIel . suel Aau86aa 00902 3AIVA 31JHM-03Uഀ Z'Sഀ L'Zഀ ' lഀ b' Lഀ 6'ഀ 9'ഀ sql -'LMഀ Lbഀ OEഀ 6Lഀ tlLഀ TLഀ TVഀ Aoഀ lL'9ഀ LVt,ഀ 6'£ഀ WEഀ LS'Zഀ 9£'Zഀ Llഀ 89'Lഀ £'9ഀ Z£'9ഀ ES'tiഀ t6'Eഀ 9l'£ഀ lഀ 9L'tlഀ L'Eഀ EZ'Eഀ 9L'Zഀ Z£'Zഀ £6' Lഀ Hഀ SZ' Lഀ 0' lഀ 9L'ഀ SL'ഀ S'ഀ 9L£'ഀ £Pഀ EE L'Zഀ EE9' lഀ ME' Lഀ Ml Lഀ l88'ഀ LE9'ഀ xelry opഀ 8Z L'Zഀ 9Z9' Lഀ 8LE' Lഀ SZ l' Lഀ LL8'ഀ LZ9'ഀ UM OPഀ L6' Lഀ 89' Lഀ 9Z' Lഀ 86'ഀ 6L'ഀ 69'ഀ LPഀ Zഀ Z/L-Lഀ V/L-Lഀ Lഀ V/Eഀ anഀ azlSഀ elea aAIeA'8 (•sql-S040ul) s;yfiiayM `suoisuawlaഀ -ഀ laogS passaidwooഀ LaiIse!oഀ bഀ t,0E-oi7zvഀ IooLS SSalulelSഀ uaalogഀ Eഀ 009E80-Z9sഀ azuoig 4sa0ഀ deoഀ Zഀ 009£8o-Z9aഀ ezuojg lseoഀ Apogഀ Lഀ uolleal;loadgഀ lelaalewഀ uolidlioseaഀ wallഀ suoi}eoilioodS V slelieloWഀ 09 lഀ 9L Lഀ OOZഀ 093ഀ (VIS6 OPw6ഀ 00Zഀ OSZഀ OOEഀ 00Zഀ Z£g W1Sb)ഀ 9LZഀ 09Eഀ OObഀ 09Lഀ Auowlluyഀ 00£ഀ OOt,ഀ 009ഀ 00 Lഀ Ull 9-96ഀ X-24-Zഀ wZ-.ti/VLഀ J-,.8/Eഀ =1 -6opഀ slulo!ഀ (ISd) ainssald 6u!Njom wnwlxeihlഀ dwal 6uiNjoMഀ u! pasn aaplosഀ ajnssaad uhPoM uoഀ ;oauu03ഀ 08-dS-SSW •ഀ lno uealo ql!m deo papeaayl .ഀ uaaaos gsen 02; laals ssalulelS •ഀ spu3 JOPioS .ഀ Apoe azuae .ഀ JOM #006 / dSM #09lഀ sainjeej Ionpoadഀ U;-«Z/0 aaulealS aaploS ozuoa8 AMഀ 8L8£ # ein6i jഀ 6£ 109 11 's}4619H alepualo `anlad uopueJ8 41JON 9Z ' Oul 'Lwa4loa!ds 90OZഀ (Aluo eouaialai 101 suoisuawi(I)ഀ MOOഀ IN1091ഀ W19Z1ഀ W1001ഀ 1:I9L0ഀ -UrA 'oN lapolNഀ .ഀ ovഀ OEഀ 91ഀ Mഀ oaf}ഀ w moldഀ 9'8ഀ 9'17ഀ 017ഀ 9'Eഀ 0'£ഀ sql 14 !aMഀ ZKഀ ഀ Z/►ഀ `d/Nഀ sa40ul aഀ Z'9ഀ TEഀ 9'Eഀ 9'£ഀ i7eഀ sa4ou 1ഀ £'Zഀ 91ഀ 91ഀ 8'0ഀ sa43ul 14ഀ 8'01ഀ V6ഀ 8'Lഀ 0'Lഀ 0'9ഀ s24oul 1Hഀ 0'bഀ 9'Zഀ 9'Zഀ 9'Zഀ 9 Zഀ sa4oul 0ഀ Jഀ "WEഀ 1dN azlg a ld pഀ :saIoNഀ -AoOLZ ain}eja uaal ugeia o -xelNഀ is 091 ainssaad u1)ljoM -RUINഀ Ja oo wrnpaVy ulosal o5ഀ uo}!n u!a oഀ uo3!n le sഀ snojja:j-uoN 1801-ഀ ssei8 peaH 3uanഀ sseae Po8ഀ :suoijeogpeasഀ ..Zഀ uolleool ezls MOIJ lepovy e1ഀ :am je}uasaada~jഀ :iopealuooഀ :jaau16u3ഀ :aweN qofഀ aoleulwII3 v,alggngoaoiw aoiunr ®MuanoJidSഀ s barnഀ elea le:glwgnS (,)wa3HJ IIdSഀ RWVഀ Product Featuresഀ • 150#WSP / 600# WOGഀ • Forged Brass Bodyഀ • Full Portഀ • Adjustable Packingഀ • Solder Endsഀ • Blowout Proof Stemഀ • NSF 1/2"-2"ഀ Figure # 5595Fഀ Brass Ball Valve (1/2"-2")ഀ Pressure/Temperature Ratingsഀ 600 PSI from 15F to 160E 150 PSI MAX at 366Fഀ Connectഀ ion Working Pressureഀ Solder used inഀ Working Tempഀ Maximum working pressure (PSI)ഀ jointsഀ deg. Fഀ 3/8'1 "ഀ 1-114"-2"ഀ 2-1/2"-3"ഀ 95-5 Tinഀ 100ഀ 500ഀ 400ഀ 300ഀ Antimonyഀ 150ഀ 400ഀ 350ഀ 275ഀ (ASTM B32ഀ 200ഀ 300ഀ 250ഀ 200ഀ grade 957A)ഀ 250ഀ 200ഀ 175ഀ 150ഀ Materials & Specificationsഀ Itemഀ Descriptionഀ Materialഀ Specificationഀ 1ഀ Bodyഀ Brassഀ B283 C37700ഀ 2ഀ End Pieceഀ Brassഀ B283 C37700ഀ 3ഀ Baliഀ Brass/Chrome Platedഀ B283 C37700ഀ 4ഀ Seatഀ PTFEഀ PTFEഀ 5ഀ Stemഀ Brassഀ B124 C37700ഀ 6ഀ Packingഀ PTFEഀ PTFEഀ 7ഀ Packing Nutഀ Brassഀ B124 C37700ഀ 8ഀ Handleഀ Zinc plated steelഀ A36 Dacrometഀ 9ഀ Handle Nutഀ Zinc plated steelഀ A36 Dacrometഀ 10ഀ I.D. Informationഀ N/Aഀ N/Aഀ Dimensions, Weights (inches-lbs.) & Valve Dataഀ Sizeഀ 1/2ഀ 314ഀ 1ഀ 1-1/4ഀ 1-1/2ഀ 2ഀ Aഀ 627-ഀ .631ഀ .877-ഀ .881ഀ 1.128-ഀ 1.131ഀ 1.378-ഀ 1.381ഀ 1.628-ഀ 1.632ഀ 2.128-ഀ 2.132ഀ Cഀ .51ഀ .75ഀ .91ഀ .97ഀ 1.09ഀ 1.34ഀ Hഀ 2.13ഀ 2.26ഀ 2.57ഀ 2.79ഀ 3.28ഀ 3.58ഀ Lഀ 3.60ഀ 3.60ഀ 4.98ഀ 4.98ഀ 5.57ഀ 5.57ഀ Pഀ .59ഀ .79ഀ .98ഀ 1.26ഀ 1.57ഀ 1.97ഀ Cvഀ 15ഀ 30ഀ 60ഀ 110ഀ 130ഀ 360ഀ Wt.- lbs.ഀ .4ഀ .6ഀ 1ഀ 1.4ഀ 2.4ഀ 3.4ഀ 9ഀ 8ഀ Lഀ at,I - A .ഀ Cഀ RW RED-WHITE VALVE 20600 Regency Lane • lake Forest, CA 92630ഀ tel: 949.859.1010 • fax: 949.859.7200 • www.redwhkevalveuss.comഀ 2 3 A ` 5ഀ Aഀ KAIBAB PLUMBING INC.ഀ CUSTOM PLUMPING / HEATING / SNOWMELT SYSTEMSഀ August 4, 2V-V7ഀ Dayton Residence gas systemഀ The natural gas system consists of Sched 40 Black iron pipe, with a run of yellow poly to an outdoorഀ fire pit.ഀ There will be a 2# delivery pressure to (2)regulators.ഀ R-1 will serve the two Lochinvar KBN 500 boilers in mechanical room.ഀ R-2 will serve the remaining fixtures in the residence-ഀ One fireplace, one cook top, one BBQ, one fire pit, one patio heater, and two clothes dryers.ഀ Regulators 1 & 2- Maxitrol Mdl.325-7Lഀ Total house load is 2,335 MBHഀ Gas value is 808 BTU/Cult.ഀ Total adjusted system demand is 2,889CFHഀ Sizing completed per I.F.G.C.2003ഀ Med. Pressure per chart #402.4(3)ഀ Low Pressure per chart #402.4(2)ഀ Please see attached schematic for specific line sizing and approximate install lengths.ഀ Thank you,ഀ J.W. Sutherlandഀ P.O.BOX 1451 EAGLE COLORADO 81631 (970)390-7735 (970)328-7732(F)ഀ Jഀ Fഀ gഀ VNഀ ofഀ 70ഀ i°ഀ ഀ eഀ 1ഀ ~ഀ iഀ lഀ 46ഀ xഀ y:ഀ 1ഀ to rഀ 3ഀ iഀ '7►ഀ $w~ in"""s.ഀ iഀ ,,.rteഀ ഀ \ഀ ~ഀ ~ഀ KAIBAB PLUMBING INC.ഀ CUSTOM PLUMBING / HEATING / SNOWMELT SYSTEMSഀ P.O.I OX 1451 EAGLE COLORADO 81631 (970)390-7735 (970)328-773L(F)ഀ Dayton Residence Control Packageഀ The following is an outline of the proposed Tekmar control system for the boiler and heating systems.ഀ As outlined, the Teknet 4 system controls modulation of both boilers simultaneously. Although the designഀ requirements of the system now require the boilers to provide primarily outlet and return temperatures outside theഀ condensing range of the boilers, some adjustments are allowable to maintain a lower supply temperature duringഀ radiant heat calls with no other boiler requests.ഀ All thermostats are Pulse Width Modulation models with Two stage units in the Master bedroom and Game room.ഀ Temperature control of the following zones will be via remote mounted thermostats with Room Temperature Unitsഀ mounted in the rooms. This will prevent guests from over adjusting the thermostats in common areas.ഀ Zone #2-ഀ Entryഀ Zone#13-ഀ laundry, powder, hall, pantryഀ Zone#14-ഀ Kitchenഀ Zone#16-ഀ Living room, Dining roomഀ Zone#17-ഀ Game roomഀ Zone#18-ഀ Loftഀ Unoccupied settings will setback house temperature, setback or interrupt domestic hot water production, andഀ interrupt snowmelt operation (if desired). Setback of spa temperature is possible, but requires co-ordination withഀ the spa contractor in order to integrate into their control system.ഀ Material and component cost for the system outlined will be $7,490.00.ഀ Wiring and programming costs will be $3,200.00ഀ Total cost of DDC system as outlined $10,690.00ഀ Thank you,ഀ J.W.Sutherlandഀ Kaibab Plumbing Inc.ഀ Zഀ Oഀ c: Cp -iഀ Qഀ ✓ CD 0ഀ 0ഀ s/, rഀ CD Wഀ CDഀ r^ ~ഀ CD 401 CDഀ Oഀ 0 (nഀ 2 CDഀ C3 nഀ ~ഀ Qഀ ഀ Zഀ 0ഀ .-rഀ Tഀ N "7CD CDഀ CD ~ ~ഀ "Sഀ -CDIഀ CL aഀ 0 -41ഀ CD 0ഀ Lഀ Cഀ c >~zഀ nഀ Y !C ~ rഀ Vഀ 3 coഀ Zഀ v coഀ zഀ ഀ ഀ yJuഀ R6.-ഀ tഀ Lഀ g ; ~ awrrഀ z x gam,ഀ Oഀ 7'ഀ Qഀ Mഀ 'L cഀ R Rഀ ~I a=ഀ E y rഀ F4 'ഀ iv D, R2ഀ R ~f * s a + aഀ x x r_ W2ഀ 4ഀ zr nഀ F-ഀ Oഀ Zഀ R~ഀ 7C5ഀ Oഀ a~ഀ \ഀ fഀ Sഀ hഀ 1QV`ഀ Zഀ !aഀ ~ഀ -ഀ X ~ഀ .;aഀ FAV!ഀ aഀ .ഀ 9ഀ aഀ . i is-xഀ aഀ =9 _ sഀ i } ~ t g S d <ഀ a a'alഀ a xഀ 4 tlaഀ • j35 3 r aeaഀ a .Sec Sz aഀ t -ഀ aഀ aiഀ a YI~~} X E~ aഀ 'firഀ D. t~sa p~ .3ഀ itഀ ^a ~ ~ ~ {aഀ f ~aഀ a t u {aഀ is aഀ ®tlഀ ~a,j `txaaxeaxaxx~.g ;ഀ Nഀ 0ഀ ZI%ഀ 77Zഀ Cഀ 1 1ഀ Qഀ Oഀ fnഀ CDഀ CA C3 ~ഀ ~ nഀ Oഀ CZ 3 ct?ഀ p Nഀ --nഀ =r CDഀ O :ഀ CD 0 Cnഀ 3 Nഀ CD O CDഀ -0ഀ Cഀ -0 0ഀ Cnഀ C7 Oഀ 0 =ഀ to zഀ Oഀ CD CDഀ m mഀ aഀ :lzഀ cnഀ z zഀ 19ഀ N.ഀ t"~ഀ :nഀ s ~ഀ -1 7ഀ Mഀ mഀ Rഀ Vഀ Zഀ Oഀ CD CDഀ cCഀ caഀ 41ഀ C ~ഀ Oഀ ~ iഀ Oഀ 3ഀ vonഀ 'ഀ :ഀ ,ഀ .ഀ CD 0ഀ Oഀ Nഀ ` cഀ r~ ^ഀ (D CD V/ഀ ഀ CDഀ CD Oഀ O Oഀ f)ഀ ഀ ഀ n (ഀ ഀ ഀ .°-rsഀ nഀ Oഀ Q :3ഀ O CDഀ oഀ CDഀ CDഀ 2)ഀ 0)ഀ CDഀ Z)ഀ Cഀ rഀ Oഀ Qഀ C-Nഀ Dഀ V Jഀ x ~ഀ aYഀ v 4ഀ aTJ aഀ Mഀ LLഀ ~ ~vsഀ s~ഀ NOഀ I Iഀ jr nഀ P ¢ E r~ഀ i0ഀ mഀ saIഀ "WAഀ IVA68ഀ ttഀ liltഀ Nഀ vഀ 0ഀ Kഀ 'ഀ - ~zഀ C 1ഀ _l fഀ Zഀ v CDഀ CDഀ c cnഀ 0mg-ഀ cn CL. ~ഀ 0ഀ Oഀ CL 3 caഀ 0ഀ oഀ ഀ CD 2)ഀ CDഀ < Gഀ CD O CDഀ ~ r *3ഀ cnഀ 5.0ഀ 0 oഀ 0 CDഀ Zഀ Oഀ 5'ഀ ~ -0 mഀ svഀ CL Qഀ 71ഀ RSഀ ZINഀ 4ഀ h~ഀ Cnഀ _Y-ഀ t~t a=mഀ ELMഀ ~cഀ `zഀ 'ഀ Cഀ ~ഀ ~ഀ sഀ tഀ EIഀ tഀ sഀ Es aഀ ~{S~ SCR. ggL.~ ♦~7ഀ 4p _ e p,~ b riMiഀ it it D ; vഀ mഀ w m.' 4 Oഀ ® § Iseഀ & =~§1ഀ ° glഀ 3 > rഀ g 43 3ഀ tie;ഀ Fഀ Oഀ Qഀ yഀ nഀ Iii^4ഀ zഀ 0ഀ C Nഀ 03ഀ c inഀ =ഀ in CLഀ Oഀ g. 3ഀ 0ഀ =r CDഀ O 3ഀ = toഀ ro Wഀ Cഀ CD o rnഀ vഀ c' gj toഀ 1. CDഀ Vi M wഀ Q. n Oഀ 0ഀ 'Gഀ 0 CDഀ CA zഀ 0ഀ CD o CDഀ CD ~ Oഀ aഀ oഀ rt ~ഀ ACT ~ഀ 41ഀ N~ഀ s F~ ? _ഀ rഀ r x~ഀ ~~Y3ഀ Y~ഀ i~Y=ഀ 3ഀ Nഀ Oഀ 0ഀ ഀ sax .cഀ zഀ 0ഀ ~ Cf1ഀ CD fl.ഀ cn Cഀ 0ഀ a340ഀ ci) 0ഀ 0ഀ =r CD Oഀ 0 :ഀ rM Nഀ CD M chഀ CDഀ ::r CDഀ CD 0 CDഀ ~ rഀ o oഀ cn' U)ഀ 0.0 0ഀ O CADഀ (n zഀ 0 -U -aഀ Xഀ ~CDഀ CD O)ഀ CD CD C-D%ഀ : Q C1ഀ m 0ഀ Qഀ Oഀ zഀ 9ഀ 1ഀ ~Gഀ 3ഀ rഀ vഀ Oഀ C~ഀ =tഀ Xഀ Cഀ vഀ °ഀ r~ഀ °ഀ 1ഀ 1ഀ 1 qഀ 1ഀ rഀ 1ഀ iഀ 1 ~ഀ ~;'l Oഀ 1ഀ 1ഀ ~ \yഀ Z /ഀ 1ഀ 1ഀ 1ഀ yഀ 7CSഀ 1ഀ vഀ 'ഀ 1ഀ ~ഀ q Oഀ tഀ 1ഀ fഀ 7~ഀ 1ഀ fഀ \;1ഀ ~ഀ 1ഀ 1ഀ 1ഀ lഀ ,ഀ zഀ 3ഀ Nഀ r Wഀ P chഀ ~ Vഀ g coഀ ,ഀ - -ഀ ~ഀ Nഀ / C } tഀ 1ഀ 1ഀ 1 1ഀ b14ഀ f 1ഀ 1 , N 1ഀ a , t 1ഀ a 1ഀ , , f 1ഀ , 1 1 1ഀ 1 } 1 e l~-ഀ ® , 8 8ഀ ഀ 9.;--------------w-.--..-.-.........i...w.................~ tഀ .................l.........ഀ #ഀ Aഀ 1 1 # ,ഀ o f O t iഀ # / ~ 1 1ഀ 1ഀ }ഀ 1ഀ # 1 ~ ~ 1 1ഀ 1 ,ഀ i °ഀ lipഀ tഀ 1ഀ y~ = 1ഀ 1ഀ R~ X 1 1ഀ 7SS ~ ~.~11.~~ 1 ,ഀ 1ഀ -CS w 8ഀ 1ഀ ഀ vഀ ~ഀ Wഀ 'Eഀ Nഀ t 1ഀ 1ഀ ; 1ഀ ഀ 1ഀ Cഀ ഀ Gഀ ;ഀ )ഀ Dഀ ~ Nഀ Wഀ Vഀ Zഀ C CD•ഀ CDഀ sv zഀ ~ cnഀ (Dഀ CL vഀ Oഀ a ~ cQഀ O Oഀ ? CD Oഀ Oഀ c`ഀ (n"ഀ Nഀ < ? Cഀ C O VOiഀ fA Nഀ O` 0 Oഀ O ,C,D^ `!Cഀ VI Zഀ Oഀ V Vഀ CD cD CDഀ CD CDഀ ~ cz, ca.ഀ 3Kഀ ~R 77ഀ }ഀ i"tfഀ 91,ഀ Vഀ rnഀ iഀ 7ഀ 7ഀ \1ഀ 8ഀ xഀ L-_ഀ M i rഀ L'ഀ Y rഀ L ; e~ wഀ iഀ 3 E ~ഀ 4 Y ~Y1ഀ F~ഀ d?fi sഀ mooഀ Pr *4 TRaiഀ iഀ 12ഀ r S-ell ® litഀ L9 Y F 3Z s.ഀ Y Oഀ SAY aഀ Lax Y dn: t y & ~ഀ L a prarrr.F~:~ q-ഀ uഀ P=:ഀ ~ 8s ?ഀ f-ഀ sഀ Oഀ : Oഀ 5ഀ Zഀ r3ഀ 7CSഀ saഀ Yഀ tഀ ഀ =ഀ g gaഀ •ഀ i j§yAf}ഀ iiഀ <ഀ .aഀ 2ഀ ~ t 5 Sixഀ ' iഀ aഀ qY S d F? t if aഀ tldഀ i 4ഀ Lt_ L At}ഀ iഀ ~2ഀ S~ Sf fj~ഀ s''ഀ Ps~y S{ഀ ~ഀ faഀ zഀ c4ഀ iഀ qഀ ഀ 1 liftഀ cRഀ Yaഀ a p ~f'aഀ _gഀ Aഀ ` E 2 j[2#ഀ Oഀ tഀ E}ഀ 3•ഀ tഀ gഀ Sഀ a nഀ x f ~ഀ Rഀ ~Iഀ .ഀ rfiഀ 21ഀ _ -ഀ gഀ 77ഀ / Vഀ Zഀ zഀ 1~33ഀ oഀ CDഀ C Cഀ Dഀ .ഀ c CDഀ 777ഀ sv -0ഀ C v,ഀ CDഀ 3ഀ ZRഀ aഀ ccഀ v 0ഀ cnഀ =r CDഀ rrtഀ Gഀ ~ഀ S ' Xഀ f a ~ zഀ f1ഀ Cc Lഀ -ഀ CD Q) (nഀ 7zഀ -ഀ R 4ഀ CDഀ yഀ sഀ = aഀ Nഀ <ഀ ®iഀ cഀ Oഀ CD O CDഀ Cഀ oഀ r- 0ഀ 0ഀ Oഀ jഀ xഀ Zഀ oഀ 2) CDഀ Wഀ 0.0 0ഀ CLഀ s~ഀ cn Zഀ yഀ zഀ ~ഀ Qഀ Oഀ zഀ CD CD CDഀ (Uഀ Qഀ .ഀ Qഀ cr Oഀ 4ഀ ഀ 7Mഀ zഀ VNNഀ zഀ Cഀ zഀ itt ~ഀ ~ഀ 2ഀ Wഀ \1ഀ sഀ gഀ Nഀ rഀ Nഀ mഀ 0ഀ Cഀ xഀ {ഀ cഀ 0ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE ATഀ MWA*VE'ഀ Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657ഀ p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149ഀ MECHANICAL PERMITഀ NSFRഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ OWNER DAYTON, JOHN W. & ARLENE J. 07/17/2008ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT VIERECK FIREPLACE SALES, INC 07/17/2008 Phone: (952) 440-5620ഀ 16151 MAIN AVENUE 5Eഀ PRIOR LAKEഀ MINNESOTA 55372ഀ License: 397-Mഀ CONTRACTOR VIERECK FIREPLACE SALES, INC 07/17/2008 Phone: (952) 440-5620ഀ 16151 MAIN AVENUE 5Eഀ PRIOR LAKEഀ MINNESOTA 55372ഀ License: 397-Mഀ Desciption: INSTALL INDOOR GAS FIREPLACE AND OUTDOOR FIREPITഀ Valuation: $12,000.00ഀ ALL TIMESഀ Permit M08-0170 <<~~ഀ Projectഀ Statusഀ Appliedഀ Issued. . .ഀ Expires .ഀ PRJ06-0162ഀ ISSUEDഀ 07/17/2008ഀ 10/31/2008ഀ 04/29/2009ഀ ..................~~.~,k.~.....~~~x~....~~~.......~.FEE SUMMARY~~~~.....~~~~,~x..~..,..,~~~.,.~,~...x...,,.,....~........,t....~.,...,~....««.,................ഀ Mechanical Permit Fee---> $240.00 Will Call > $4.00 Total Calculated Fees $304.00ഀ Plan Check > $60.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $0.00ഀ Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $304.00ഀ Total Calculated Fees--> $304.00 Payments-----------------> $304.00ഀ BALANCE DUE--------- > $0.00ഀ APPROVALSഀ Item: 05100 BUILDING DEPARTMENTഀ 07/18/2008 GCD Action: DN OUTDOOR FIRE FEATURES REQUIRE DRB APPLICATION ANDഀ APROVAL. SUBMIT INSTALLTION INSTRUCTIONS; FOR BURNER, CONTROLS, AND PLAN SHOWING DETAIL FORഀ CONSTRUCTION.ഀ 10/28/2008 GCD Action: APഀ CONDITION OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ Cond: 25ഀ (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informationഀ as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structureഀ according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Townഀ applicable thereto.ഀ REQUESTS - 4 FOR j~JS rCJN .5t"LL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(ഀ ~00ഀ Dateഀ Nameഀ m e ch ca n ica I_pe rm it_041908ഀ kO'TE: THIS PERMIT MUST BE POSTED ON JOBSITE ATഀ MWO Vv .ഀ Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657ഀ p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149ഀ ALL TIMESഀ MECHANICAL PERMITഀ NSFRഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....:ഀ Parcel No...: 210107113012ഀ OWNER DAYTON, JOHN W. & ARLENE J. 09/04/2008ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT SKYLINE MECHANICALഀ P.O. BOX 1258ഀ GYPSUMഀ CO 81637ഀ License: 121-Mഀ CONTRACTOR SKYLINE MECHANICALഀ P.O. BOX 1258ഀ GYPSUMഀ CO 81637ഀ License: 121-Mഀ 09/04/2008 Phone: 970-524-6809ഀ 09/04/2008 Phone: 970-524-6809ഀ Desciption: NEW SINGLE FAMILY RESIDENCE (SFR): INSTALL VENTILATION, AIRഀ CONDITIONING AND HUMIDIFICATION SYSTEMS.ഀ Valuation: $30,000.00ഀ Permit M08-0220 X01 ?ഀ Projectഀ Statusഀ Appliedഀ Issued. . .ഀ Expires,ഀ ഀ PRJ06-0162ഀ ISSUEDഀ 09/04/2008ഀ 09/04/2008ഀ 03/03/2009ഀ ............................t. ********•*****"*******FEE SUMMARY......*..«*.......«.....*****............,.*.................+..........««..ഀ Mechanical Permit Fee---> $600.00 Will Call > $4.00 Total Calculated Fees $754.00ഀ Plan Check > $150.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $55.00ഀ Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $809.00ഀ Total Calculated Fees--> $754.00 Payments-----------------> $809.00ഀ BALANCE DUE--------- > $0.00ഀ APPROVALSഀ Item: 05100 BUILDING DEPARTMENTഀ 09/04/2008 JLE Action: APഀ CONDITION OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the informationഀ as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structureഀ according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Townഀ applicable thereto.ഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY -BUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0(ഀ AM - 4 PM.ഀ Signature of Owner or Contractorഀ Print Nameഀ / / ~ Cഀ ateഀ mechcan ical_perm it_041908ഀ Fഀ TOWN OF VAIL, COLORADOഀ Statementഀ Statement Number: R080001545 Amount: $809.00 09/04/200804:38 PMഀ Payment Method: Check Init: SABഀ Notation: 13538ഀ skylineഀ mechanicalഀ ഀ Permit No: M08-0220 Type: MECHANICAL PERMITഀ ഀ Parcel No: 2101-071-1301-2ഀ Site Address: 344 BEAVER DAM RD VAILഀ Location:ഀ Total Fees:ഀ $809.00ഀ This Payment: $809.00 Total ALL Pmts:ഀ $809.00ഀ Balance:ഀ $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Code Description Curreഀ ഀ nt Pmtsഀ ഀ CL 00100003123000 CONTRACTOR LICENSESഀ ഀ 55.00ഀ MP 00100003111100 MECHANICAL PERMIT FEESഀ 600.00ഀ PF 00100003112300 PLAN CHECK FEESഀ 150.00ഀ WC 00100003112800 WILL CALL INSPECTION FEEഀ 4.00ഀ Sep 04 2008 10:50AM Skyline Mechanical INC. 970-524-6810ഀ p.1ഀ 4 794ഀ - 1? Yjഀ Mechanical Room Lavout drawn to scalp to include:ഀ Mechanical Room Dimensionsഀ Combustion Air Duct Size and Locationഀ Flue, Vent and Gas Line Size and Locationഀ Hest Lose Calculationsഀ Equipment Cut / Spec Sheetsഀ Project Addressഀ ( L Project Vഀ _.......J......._'.V..'eo ~/~e Bullding Permit R^7-_0/2gഀ Contractor Information 1%ഀ 'Mechanical Permit#: Mഀ Company: nCLQ 2 D-oഀ Company Address rഀ Detailed Description of Work: P~,r le! 14 Lഀ c:ty:1T l~Gr t staters-sz zip: 7 •6 l f~'1'~ tഀ a..'Vഀ Contact Name: rKഀ Contact Ph: _S [f'.-~~f~a 9 Cell:ഀ E-Mail: jftdO C•1~i4•V/ Lഀ a se additional sheet If necessary)ഀ i • Town of Vail Contractor Registration No: Complete Valuation for Mechanical Permit:ഀ ~t MechanicaI$ %0 47~ Q®0ഀ onttacthor Si naturo (ro ulred)ഀ 9 qഀ Property Informationഀ Work Class:ഀ Parcelഀ 210(Q211 '3 dഀ New Y) Addition ( ) Remodelഀ "wഀ Legal Oescriptio : Lot # _ o 3_, Bilk #__,2 _ഀ Boller Location:ഀ bഀ iഀ iഀ iഀ Ira/ 1ഀ Interior ( ) Exterior ( )ഀ vഀ %ഀ Suഀ dഀ sഀ on:ഀ No/Type Existing Fireplaces:ഀ Aഀ Job Name: nn v Aഀ YAo --f/ Ae rഀ Gas Appliances( ) Gas Logs (ഀ Jഀ Owner Name: Q A~T"y TO 1~it/ of l~ P.r/eഀ Nam ype Proposed Fireplaces:ഀ Nlailtrio Address:E2B3 [h! t& S~ Oil ajjS.M Appliances( ) Gas Logs (ഀ (For Pa: cel f Contia Eagle County assessors Office at 870-328-8840 or v sit rഀ ~ഀ Buildinഀ Tഀ e;ഀ www.eaglecounty.us/patie)ഀ gഀ ypഀ Single-Family Two-Familyഀ Architect( ) Designer( ) Engineer( )ഀ Commercial( ) Townhome (ഀ )ഀ Name:ഀ Phone:ഀ Fax:ഀ E-Mail:ഀ Date Received:ഀ Repair ( )Other(ഀ )ഀ Other ( )ഀ Wood/Pellet ( )ഀ Wood/Pellet ( )ഀ Multi-Family ( )ഀ Other( )ഀ LA Cbഀ TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENTഀ 75 S. FRONTAGE ROADഀ VAIL, CO 81657ഀ 970-479-2138ഀ NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMESഀ PLUMBING PERMITഀ Job Address: 344 BEAVER DAM RD VAILഀ Location.....: 344 BEAVER DAM RDഀ Parcel No...: 210107113012ഀ Legal Description: .yam _pഀ Project No :ഀ OWNER DAYTON, JOHN W. & ARLENE J. 08/14/2007ഀ 2703 ROUTH STNEഀ DALLASഀ TX 75201ഀ APPLICANT KAIBAB PLUMBING INCഀ P.O. BOX 1451ഀ EAGLEഀ CO 81631ഀ License: 282-Pഀ CONTRACTOR KAIBAB PLUMBING INCഀ P.O. BOX 1451ഀ EAGLEഀ CO 81631ഀ License: 282-Pഀ Permit P07-0121ഀ _t06' 0S~t I -ZO -GkRഀ Statusഀ ISSUEDഀ Applied..:ഀ 08/14/2007ഀ Issued .ഀ 08/31/2007ഀ Expires.ഀ 02/27/2008ഀ 08/14/2007 Phone: 970-390-7735ഀ 08/14/2007 Phone: 970-390-7735ഀ Desciption: ROUGH PLUMBING, ROOF DRAINAGE, NATURAL GAS SYSTEMഀ Valuation: $82,855.00ഀ Fireplace Information: Restricted: # of Gas Appliances: # of Gas Logs: # of Wood Pallet:ഀ FEE SUMMARYഀ Plumbing $1,245.00 Restuarant Plan Review-->ഀ $0.00 Total Calculated Fees $1,559.25ഀ Plan Check $311.25 TOTAL FEES--------------> $1,559.25 Additional Fees-----------> $0.00ഀ Investigation-> $0.00 Total Permit Fee---------- > $1, 559.25ഀ Will Call-----> $3 .0 0 Payments > $1,559.25ഀ BALANCE DUE--------- > $0. 00ഀ Item: 05100 BUILDING DEPARTMENTഀ 08/14/2007 cgunion Action: APഀ Item: 05600 FIRE DEPARTMENTഀ CONDITION OF APPROVALഀ Cond: 12ഀ (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.ഀ ഀ DECLARATIONSഀ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,ഀ and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with allഀ Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design reviewഀ approved, International Building and Residential Codes and otherഀ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS INഀ of the Twan applicablഀ ANCE Bl' ;VELYPHONE\AT 479-2149 OR ATഀ FROM 8:00 AM - 4 PM.ഀ SIGPATURE4WOW-NER OR VONTRACTOR FOR HIMSELF AND OWNERഀ TOWN OF VAIL, COLORADOഀ Statementഀ Statement Number:ഀ R070001741 Amount: $1,559.25 08/31/200710:28 AMഀ Payment Method:ഀ Check Init: LTഀ Notation: Tempഀ Bank Check /ഀ ഀ Permit No:ഀ ഀ P07-0121 Type: PLUMBING PERMITഀ ഀ Parcel No:ഀ 2101-071-1301-2ഀ Site Address:ഀ 344 BEAVER DAM RD VAILഀ Location:ഀ 344 BEAVER DAM RDഀ Total Fees:ഀ $1,559.25ഀ This Payment:ഀ $1,559.25 Total ALL Pmts:ഀ $1,559.25ഀ Balance:ഀ $0.00ഀ ACCOUNT ITEM LIST:ഀ Account Codeഀ ഀ Descriptionഀ ഀ Current Pmtsഀ PF 00100003112300ഀ ഀ PLAN CHECK FEESഀ ഀ 311.25ഀ PP 00100003111100ഀ PLUMBING PERMIT FEESഀ 1,245.00ഀ WC 00100003112800ഀ ഀ WILL CALL INSPECTION FEEഀ ഀ 3.00ഀ ഀ Jkഀ TOi~' O'Vഀ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNS bഀ Project Vഀ Building Permitഀ Plumbing Permit 6: ~A7 -ഀ (I sped nsഀ 970-479-2149ഀ lഀ 75 S. Frontage Rd. C . Zഀ Vail, Colorado 81657 I Tഀ TOWN OF "IL PLUMBING PERMIT APPLICATIONഀ CONTRACTOR INFORMATIONഀ Plumbing Co tr or: Town of Vail Reg. No.: ILI-W ontact Person and Phone #'s:ഀ PA 1- Ig b/u 2e2 -P .ഀ E-Mail Address: a~ Jj v~ b~~v JAG ,q ov Fax 170 3Z~5 '7-132_ഀ Co act S' na re:ഀ / L_CO~PLETE VALUATION FOR PLUMBING PERMIT (Labor & Materials)ഀ PLUMBING: $ 6 2-e6S Oഀ le'^HN&V Ac~nccneC nfti/'o ~t 07n_ ~7R_RRQA nr vicit mlww PA/71P-lniin}V f nm fnr Par! Plഀ Parcel #ഀ Job Name: rl~lS Ls5/Ncഀ Job Address: 3~ Bഀ Legal Description Lot: Ib 11 Block: 21 Filing:ഀ _ഀ Subdivision:ഀ Owners Name: DA-YTpl,'J Address:ഀ Phone:ഀ Engineer: ~ vor Address:ഀ Phone:ഀ Detailed description of work: RC)Q M 61 t~'3yഀ N A E?ഀ Work Class: New Addition( ) Alteration ( )ഀ Repair ( )ഀ Other ( )ഀ Type of Bldg.: Single-family Duplex ( ) Multi-family ( )ഀ Commercial(ഀ ) Restaurant( ) Other(ഀ )ഀ No. of Existing Dwelling Units in this building:ഀ No. of Accommodation Units in this building:ഀ **************************FOR OFFICE USE ONLY*********************************ഀ F:\cdev\FORMS\PERMITS\Building\plumbing_permit_11-23-2005.doc Page 1 of 1 11/23/2005ഀ 07-01-2009 Inspection Request Reporting Page 15ഀ 4:00 pm Vail, CO - City Ofഀ Requested Inspect Date: Thursday, July 02, 2009ഀ Inspection Area: CGഀ Site Address: 344 BEAVER DAM RD VAILഀ 344 BEAVER DAM RDഀ A/P/D Informationഀ Activity: M08-0005 Type: B-MECH Sub Type: ASFR Status: ISSUEDഀ Const Type: Occupancy: Use: Insp Area: CGഀ Owner: DAYTON, JOHN W. & ARLENE J.ഀ Contractor: KAIBAB PLUMBING INC. Phone: 970-390-7735ഀ Description: INSTALL INFL HEAT, I,OWMELT, SPA HEAT SUPPLY AND HYDRONIC CONTROLSഀ ,Peg Item: 90 MECH-Final Requested Time: 04:30 PMഀ Requestor: KAIBAB PLUMBING IN / JW Phone: 970-390-7735, JWഀ Comments: FINAL INFLOOR HE , SPA, MECH RMഀ Assigned To: JMONDRAGON Entered By: LCAMPBELL Kഀ Action: Time Exp:ഀ tiഀ Inspection History Cഀ Item: 200 MECH-Roughഀ Item: 310 MECH-Heafing Approvedഀ 03/04/08 Inspector: JRM Action: PA PARTIAL APPROVALഀ Comment: IN FLOOR HEAT OF GARGAE ONLY 100 # AIR TESTഀ 07/30/08 Inspector: JGG Action: AP APPROVEDഀ Comment: Wirsbo pressure tested at 90psi. OK.ഀ 03/17/09 Inspector: JRM Action: AP APPROVEDഀ Comment: ALL INFLOOR HEAT COMPLETE 100 # AIR TESTഀ Item:ഀ 315 PLMB-Gas Pipingഀ Item:ഀ 320 MECH-Exhaust Hoodsഀ Item:ഀ 330 MECH-Supply Airഀ Item:ഀ 340 MECH-Misc.ഀ Item:ഀ 390 MECH-Finalഀ REPT131ഀ 11ഀ Run Id: 9940ഀ 07-15-2009 Inspection Request Reporting Page 16ഀ 8:05 am Vail, CO - City 0fഀ Requested Inspect Date: Wednesday, July 15, 2009ഀ Inspection Area: GRGഀ Site Address: 344 BEAVER DAM RD VAILഀ 344 BEAVER DAM RDഀ A/P/D Informationഀ Activity: M08-0170 Type: B-MECH Sub Type: NSFR Status: ISSUEDഀ Const Type: Occupancy: Use: Insp Area: GRGഀ Owner: DAYTON, JOHN W. & ARLENE J.ഀ Contractor: VIERECK FIREPLACE SALES, INC. Phone: (952) 440-5620ഀ Description: INSTALL INDOOR GAS FIREPLACE AND OUTDOOR FIREPITഀ Requested Inspeഀ Item:ഀ Requestor:ഀ Comments:ഀ Assigned To:ഀ Action-ഀ Comment.:ഀ Comment:ഀ ction sഀ 390 MECH-Finalഀ FIREPLACE MITCHഀ JMONDRAGONഀ Time Exp:ഀ u oor ire pi was OK, in operation.ഀ Trim to be installed later.ഀ Indor fireplace roughed in OK, ue Siഀ installed on Lutron system pri to js;ഀ Requested Time: 02:00 PMഀ Phone:ഀ Entered By: SHAHN Kഀ w/ s ut-off valve and long key shut-off on left side.ഀ ratin (auto-damper). Key pad controls to beഀ Inspection Historyഀ Item:ഀ 200 MECH-Rough Approvedഀ 11/10/08ഀ Inspector: GCD Actiഀ Comment:ഀ Item:ഀ 315 PLMB-Gas Pഀ ipingഀ Item:ഀ 340 MECH-Misc.ഀ 09/24/08ഀ Inspector: GCD Action: DN DENIEDഀ Comment:ഀ PERMIT IN DENIED STATUSഀ Item:ഀ 390 MECH-Finalഀ Approvedഀ 01/22/09ഀ Comment:ഀ Inspector: JGG Action: AP APPROVEDഀ Outdoor fire pit was OK, in operation. AGA regulator w/ shut-off valve and long key shut-off on leftഀ side. Trim to be installed later.ഀ 01/22/09ഀ Inspector: JGG Action: AP APPROVEDഀ Comment:ഀ Indor fireplace roughed in OK, flue Sentinel was operating (auto-damper). Key pad controls to beഀ installed on Lutron system prior to issuance of C of O.ഀ REPT131 Run Id: 10019ഀ 07-01-2009 Inspection Request Re orting Page 16ഀ 4:00 pm Vail, CO - City Ofഀ Requested Inspect Date: Thursday, July 02, 2009ഀ Inspection Area: JRMഀ Site Address: 344 BEAVER DAM RD VAILഀ A/P/D Informationഀ Activity: M08-0220 Type: B-MECH Sub Type: NSFR Status: ISSUEDഀ Const Type: Occupancy: Use: Insp Area: JRMഀ Owner: DAYTON, JOHN W. & ARLENE J.ഀ Contractor: SKYLINE MECHANICAL Phone: 970-524-6809ഀ Description: NEW SINGLE FAMILY RESIDENCE (SFR): INSTALL VENTILATION, AIR CONDITIONING ANDഀ HUMIDIFICATION SYSTEMS.ഀ Requested Inspecti,ഀ m: 0 MECH-Final Requested Time: 02:00 PMഀ R uestor: S YLINE MECHANICAL Phone: 970-524-6809ഀ mments: 524-6809ഀ signed To: JMONDRAG Entered By: JMONDRAGON Kഀ Action: Time Exp:ഀ Inspection Historyഀ Item: 200 MECH-Roughഀ 09/05/08 Inspector:ഀ Comment: HVAC DUഀ PROVIDEഀ PROVIDEഀ Item: 310 MECH-Heatingഀ Item: 340 MECH-Misc.ഀ Item: 390 MECH-Finalഀ REPT131ഀ Run Id: 9940ഀ ~(L~oഀ 07-01-2009 Inspection Request Reporting Page 19ഀ 4:00 pm Vail, C_. 0fഀ Requested Inspect Date: Thursday, July 02, 2009ഀ Inspection Area: cഀ Site Address: 324 BEAVER DAM RD VAILഀ 344 BEAVER DAM RDഀ A/P/D Informationഀ Activity: P07-0121 Type: B-PLMB Sub Type: NSFR Status: ISSUEDഀ Const Type: Occupancy: Use: Insp Area: cgഀ Owner: DAYTON, JOHN W. & ARLENE J.ഀ Contractor: KAIBAB PLUMBING INC Phone: 970-390-7735ഀ Description: ROUGFLPഀ _LU,MffrIWk ROOF DRAINAGE, NATURAL GAS SYSTEMഀ Ite : 290 LMB-Finalഀ Reques r: KAI PLUMBIഀ Comme ts: FINISH, MAYBഀ Assigned. o: JMONDRAGഀ Inspection History Vഀ Item: 210 PLMB-Undergroundഀ 09/04/07 Inspector:ഀ Comment: UNDERGFഀ PARTIAL Iഀ REINSPE(ഀ COMPLETഀ Requested Time: 04:00 PMഀ INC / JW Phone: 970-390-7735, JWഀ ROOF DRAIN; TOILET NOT INSTALLED DUE TO LACK OF FINALഀ NE FOR INSPഀ cdaviഀ )UNDഀ Fഀ Entered By: LCAMPBELL Kഀ Action: PI PARTIAL INSPECTIONഀ )F DRAINS.ഀ 4 SEPARATE BRANCH LINES ALL TESTED WITH 5# AIRTESTഀ 0 DRAINGAGE WILL BE REQUESTED WHEN SYSTEM ISഀ SPENT 30MIN GOING OVER ALL ROOF DRAIN SIZE CALCULATION WITH PLUMBER OFഀ RECORD = APPROVED.ഀ 09/11/07ഀ Inspector: JRM Action: PI PARTIAL INSPECTIONഀ Comment:ഀ PARTIAL UNDERGRD DRAIN ROOF DRAIN 5 # AIRഀ 11/21/07ഀ Inspector: GCD Action: CR CORRECTION REQUIREDഀ Comment:ഀ TEST PRESSURE DROPPED, LAYOUT OKഀ 02/22/08ഀ Inspector: GCD Action: PA PARTIAL APPROVALഀ Comment:ഀ GARAGE FLOOR DRAINS 5 psi TESTഀ BOILER AND SPA EQUIPMENT ROOM DRAINS 5 psi TESTഀ LOWER LEVEL LAഀ NDഀ "ഀ Uഀ RY ROOM 5psi TEST CHANGE BRANCH OR DRAINAGE STACK TO 3ഀ .ഀ Item:ഀ 220 PLMB-Rou h/D.W.V. Approvedഀ 09/04/08ഀ Inspector: JGG Action: PA PARTIAL APPROVALഀ Comment:ഀ 0ഀ /0ഀ /ഀ Some DWV inspected today, not completed.ഀ Iഀ Gഀ 9ഀ 5ഀ 08ഀ nspector:ഀ CD Action: NO NOTIFIEDഀ Comment:ഀ CANCELED BY CONTRACTORഀ 09/08/08ഀ Inspector: JGG Action: AP APPROVEDഀ Comment:ഀ All DWV tested with water column. Repaired small leak on site.ഀ Item:ഀ 230 PLMB-Rough/Water Approvedഀ 09/04/08ഀ Inspector: JGG Action: AP APPROVEDഀ Comment:ഀ Domestic water is OK.ഀ 11/18/08ഀ Inspector: GCD Action: AP APPROVEDഀ Comment:ഀ TUB/SHOWER VALVES INSTALLED STREET PRESSUREഀ Item:ഀ 240 PLMB-Gas Piping Approvedഀ 09/05/08ഀ Inspector: GCD Action: CR CORRECTION REQUIREDഀ Comment:ഀ CSST REQS NAIL PLATES NO TESTഀ 09/08/08ഀ Inspector: JGG Action: AP APPROVEDഀ Comment:ഀ 11/18/08ഀ All interior gas-tight runs OK. Properly protected w/ nail plates.ഀ Iഀ tഀ GCഀ Aഀ AP APഀ Oഀ nspecഀ or:ഀ Dഀ ction:ഀ PRഀ VEDഀ Comment:ഀ FIREPIT CSST AND BIP AND EPOXY COATED GSAPIPE 30psi TESTഀ Item:ഀ 250 PLMB-Pool/Hot Tubഀ Time Exp:ഀ Approvedഀ REPT131 Run Id: 9940ഀ M08 -0170: Entries for Item:390 - MECH -Final 13:47 02/08/2013 Action Comments By Date Unique_ Key AP Outdoor fire pit was OK, in operation. AGA JGG 01/22/2009 A000122 regulator w/ shut -off valve and long key shut- 188 off on left side. Trim to be installed later. AP Indor fireplace roughed in OK, flue Sentinel JGG 01/22/2009 A000122 was operating (auto- damper). Key pad 189 controls to be installed on Lutron system prior to issuance of C of O. AP JRM 07/17/2009 A000125 790 Total Rows: 3 Page 1 E08 -0035: Entries for Item: 190 - ELEC -Final 13:46 02/08/2013 Action Comments By Date Unique_ Key PA GARAGE GFIC DEFECTIVE shahn 07/07/2009 A000125 PROVIDE PERMANENT NAMEPLATE 581 "SERVICE DISCONNECT". SPA AND RELATED MECH ROOM SPA BONDING NOT READY. PA spa bonding approved. shahn 07/20/2009 A000125 847 Total Rows: 2 Page 1 E06 -0245: Entries for Item: 190 - ELEC -Final 13:45 02/08/2013 Action Comments By Date Unique_ Key AP shahn 04/01/2008 A000112 215 Total Rows: 1 Page 1 B07 -0192: Entries for Item-.90 - BLDG -Final 13:45 02/08/2013 Action Comments By Date Unique_ Ke AP Martin 10/22/2009 A000128 934 Total Rows: 1 Page 1 w a w Q F 0 0 0 0 0 0 w O IX w F w a F F W £ Q N N N F H 4 n a W W W h rl ti A a I II ~ h F ~ lfl I N I Ln N N a N I N I N aD Q F E ~ H ~ N H a W 00 W rl n ti H Q H I H I N a w a F4 E. I I I a a a, F F a 5 H In u1 In W W N N N x N £ 00 a~ El O W Q m l m I m a a El w a o W W m ~ o a F I o p a . \ a F a o h H rl V1 O I a \ ~ q H w x w w o w w m o F o a \ A N m N O X \ \ F r m W w N o o ~ Q N F F 11 E O U m a a E H S4 M v ei z a CN O O N N r o F a ~ v a > x H I W N U rl W a I w Ca F £ U I w W H a a w v r w z a a Q I x Q F m w a m 0 W W o W q o I O p w l P, £ W \ a o O w ° 0 5 n b xu I wca V] 4 w mw u a u q N w' H u x Q H m O O U w w m w F H F N a w 0 3 u H 0 0 4 a QS o: O O a' w \ wwF F L7 Q U IL, 'j 3G q19A`l Receipt funds to: Name: J v13. V,, ~avJ•~ Majling_ Add regs: f ] / Sv ;;~n S ~.c 2s//sj T- 7-1 2 Z y CASH DEPOSIT FORMAT Legal Description: Lot /0 Block Subdivision: , 3 Address: `r 1 Developer: e Permit Number: $o-7- 01-72 Project Number: f! P-1 n& - Cl 16 2 Improvement Completion Date: l - c~ DEVELOPER IMPROVEMENT AGREEMENT THIS AGR EMENT, madeI and tered into this l ~a day of 20_Q by and among 0- oc& 3Z SLID r I;'~. r (the "Developer"), a d the Town of Vail (the `Town"). I-J WHEREAS, the Dev toper, as a condition of approval of the Temporary Certificate of Occupancy for / A eSv* 3 h2 1 jVa c lc 2 (address, legal description, and project number) wishes to enter into a Developer Improvement Agreement; and WHEREAS, the Developer is obligated to provide security or collateral sufficient in the judgement of the Town to make reasonable provisions for completion of certain improvements set forth in the attached estimated bid(s) in accordance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vail; and WHEREAS, the Developer wishes to provide collateral to guarantee performance of this Agreement, including completion of the all improvements referred to in this Agreement, by means of the following: The Developer agrees to establish a cash deposit account with the Town of Vail, as escrow agent, in the amount of $ / 4 as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. NOW THEREFORE, in consideration of the following mutual covenants and agreements, the Developer and the Town agree as follows: 1. The Developer agrees, at its sole cost and expense, to furnish all equipment and materials necessary to perform and complete all improvements referred to in this Agreement. The Developer agrees to complete all improvements referred to in this Agreement on or before the day of ~v , 200 . The Developer shall complete, in a good workmanlike manner, all im rovements referred to in this Agreement, in accordance with all approved plans and specifications filed in the office of the Community Development Department of the Town of Vail, and to do all work incidental thereto according to and in compliance with the following: a. All said work shall be done under the inspection of, and to the satisfaction of, the Town Planner, the Town Engineer, the Town Building Official, or other official from the Town of Vail, as affected by special districts or service districts, as their respective interest may appear, and shall not be deemed F:\cdev\FORMS\Permits\Planning\Administrative-Actions\DIA cash format_5-16-2007.doc Page 1 of 5 complete until approved and accepted as completed by the Community Development Department and Public Works Department of the Town of Vail. 2. To secure and guarantee performance of the obligations as set forth herein, the Developer agrees to provide collateral as follows: A cash deposit account with the Town of Vail, as escrow agent, in the amount of $ 1 / <2 t, Z 57 as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. 3. The Developer may at any time substitute the collateral originally set forth above for another form of security or collateral acceptable to the Town to guarantee the faithful completion of those improvements referred to herein in this Agreement and the performance of the terms of this Agreement. Such acceptance by the Town of alternative security or collateral shall be at the Town's sole discretion. 4. The Town shall not, nor shall any officer or employee thereof, be liable or responsible for any accident, loss or damage happening or occurring to the work specified in this Agreement prior to the completion and acceptance of the same, nor shall the Town, nor any officer or employee thereof, be liable for any persons or property injured by reason of the nature of said work, but all of said liabilities shall be and are hereby assumed by the Developer. The Developer hereby agrees to indemnify and hold harmless the Town, and any of its officers, agents and employees against any losses, claims, damages, or liabilities to which the Town or any of its officers, agents or employees may become subject to, insofar as any such losses, claims, damages or liabilities (or actions in respect thereof) arise out of or are based upon any performance by the Developer hereunder; and the Developer shall reimburse the Town for any and all legal or other expenses reasonably incurred by the Town in connection with investigating or defending any such loss, claim, damage, liability or action. This indemnity provision shall be in addition to any other liability which the Developer my have. 5. It is mutually agreed that the Developer may apply for and the Town may authorize a partial release of the collateral deposited with the Town for each category of improvement after the subject improvement is constructed in compliance with all plans and specifications as referenced hereunder and accepted by the Town. Under no condition shall the dollar amount of the collateral that is being held by the Town be reduced below the dollar amount necessary to complete all uncompleted improvements referred to in this Agreement. 6. If the Town determines, at its sole discretion, that any of the improvements referred to in this Agreement are not constructed in compliance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vail or not accepted by the Town as complete on or before the date set forth in Paragraph 1 of this Agreement, the Town may, but shall not be required to, draw upon the security referred to in this Agreement and complete the uncompleted improvements referred to in this Agreement. Pursuant to Section 12-11-8, Vail Town Code, the Temporary Certificate of Occupancy referred to in this Agreement may be revoked until all improvements referred to herein are completed by the Developer or the Town in accordance with this Agreement. F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 2 of 5 If the costs of completing the uncompleted improvements referred to in this Agreement exceed the dollar amount of the deposit, the excess, together with interest at twelve percent (12%) per annum, shall be a lien against the property and may be collected by civil suit or may be certified to the treasurer of Eagle County to be collected in the same manner as delinque6t ad valorem taxes levied against such property. If the Developer fails or refuses to complete the improvements referred to in this Agreement, such failure or refusal shall be considered a violation of Title 12 (Zoning Regulations), of the Vail Town Code, and the Developer shall be subject to penalties pursuant to Section 12-3-10 (Violations: Penalties) and Chapter 1-4 (General Penalty), of the Vail Town Code. 7. The Developer shall warranty the work and materials of all improvements referred to in this Agreement located on Town property or within a Town right-of-way, pursuant to Chapter 8-3, of the Vail Town Code, for a period of two years after the Town's acceptance of said improvements. 8. The parties hereto mutually agree that this Agreement may be amended from time to time, provided that such amendments be in writing and executed by all parties hereto. F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 3 of 5 Dated the day and year first above written. Developer STATE OF COLORADO ) ) ss. COUNTY OF EAGLE ) The foregoing Developer Improvement Agreement was acknowled e before me this 16 Day of.Tv , 200 ' by t Witness my hand and official seal. My commission expires 7 ~j Town Planner STATE OF COLORADO ) )ss. COUNTY OF EAGLE ) Th foregoing Developer Improvement Agreement was acknowledged before me this i Day of _ 20L by (-o Witness my hand and official seal. My commission expires: t Notary Public ?v'N0TAq 1 a:•pV :y BLICA F:\cdev\FORMS\Permits\PlanningWdministrative-Actions\DIA cash format_5-16-2007.doc Page 4 of 5 ATTACHED COPIES OF THE ESTIMATED BID(S) F:\cdev\FORMS\Perrnits\Planning\Administrative_Actions\DIA cash form at_5-16-2007.doc Page 5 of 5 Town of Vail Department of Community Development 75 S. Frontage Road Vail, CO 81657 Name: a.cs-c~c SL4A~w Receipt No. QO Address: $cry RC45eLcr P',' Project: tie?' lli!gZ Date 7 / U / a4 Please make checks payable to the TOWN OF VAIL Account No. Item No. Code # Cost Each Total 001 0000 314 1110 Address Maps ZA $5.00 * 001 0000 314 1110 Zonin Maps ZA $20.00 * 001 0000 319 4400 Custom Maps 001 0000 314 1112 Other Code Books CB 001 0000 314 1211 Blue Prints/M lar Cop Fees BF $7.00 * 001 0000 314 1111 Xerox Copies XC $0.25 * 001 0000 314 1111 Master Plan MS 001 0000 314 1111 Studies, Master Plans, etc. MS 001 0000 312 3000 Contractors License Fees CL 001 0000 312 3000 Contractors License Fees - RENEWAL CL 001 0000 240 3300 Developer Improvement Agreement Deposit D2-DEP10 AD t 001 0000 312 1000 Restaurant License fee TOV RL 001 0000 230 2000 Spec. Assess.-Restaurant Fee to Co.Dept.Rev. SA 110 0000 314 1115 Resale Commission MS Other - MS Other - MS Other - MS Other - MS Other - MS 001 0000 201 1000 Taxable 4.4% State - Tax payable TP 001 0000 310 1200 Taxable 4% Town - Retail Sales Tax T7 TOTAL: t I S! • ZS' . all items charged tax Comments: Cash Money Order # Check # 09782s/ Received )3G_ Credit Card: Visa / MC Last 4 CC #'s Auth Name on CC f/cdev/forms/admin/sales action form 2007 1/5/06 Town of Vail CUSTOMER RECEIPT fv Oper: AJANUSZ Type: F8 Drawer: 1 Date: 7/22/09 01 Receipt no: 10580 Customer Location Nave Amount 2892 2903 A07-0192 GEORGE SHAE AD AR-DEPOSITS GEORGE SHAEFFER $1181.25 PERMIT$807-0192 Tender detail CK CHECK 97824 $1181.25 Total tendered $1181.25 Total payment $1181.25 Trans date: 7/22/09 Time: 10:15:05 THANK YOU FOR YOUR PAYMENT! n o 7 m m n o ~ x M ro n n n M O 3 m o m S M m ~ ~O d < m o w rt o r n O S n m n z m O Z 0 d m n a ~A 1O m H 1 n O z C o 0 ? ° 0 3 O N ~I ro Z o 0 0 ~ c H a r Z n 0 N F, r N °J r O r ~ N N ~ rt A (D rt w r- a o ~ o m b r- n O G U) M rt w 0 m O ~ r r rt ~ D 3 2 r r O 0 ~ Z N N `m N rt z m O o CO U M 2 OD F 6 N c J~- w 0 a a 4 a Q F a O a W a ❑ W IX F H W O Q N M c m 0 o O H N ❑ W w a o a 0 C W O 3 x04 0 aaF Cl F n n W O aid a F w a zz w5 H0 5 r] Q a Q z a 00 F £ W a ° 0 ~z O O wed ❑ F a 7 a W F A X F T4 F z O F a ~ U z w ❑ a w O 0 W F a❑ a OU W u u Q H F N U 0 0 0 0 0 0 0 0 oio 0 0 N N N N ~ 1 N 0 0 0 0 o i o N N N N N ~ oio 0 0 0 0 0 0 N N N N m 0 0 H m m 0 r r N Q N l~ l t71 a Oa E H ~4 N a O N N v Q W p, a v Q F z o o a F W ~a o Q W F h Q tD U fk ~ O co W N 0 0 F 0 0 0 o 0 0 N N 0 0 i N N 0 0 0 N N I F a O O F H ❑ U) O W 0 0 N ❑ a S a F a ~ O ~d 0 F 0 o o a h Q a W m 0 0 N F 0 U ri N 0 x U a m Q H a a u x U W a r +c tze,1&4e G 9/9/09\Q~~^ CASH DEPOSIT FORMAT Receipt funds to: Legal Description: Lot l~ Block_~)_ Name: hv. Subdivision: , / Mailing Address: Address: r _ 2 D 927 2 4u Takla V-%-7574-7-0 Developer: 7.S'a 2 O Permit Number. Project Number: G` - D L Improvement Completion Date: ! DEVELOPER IMPROVEMENT AGREEMENT THIS AGREEMENT, made and entered into this _LL t~day of J 20 09, by and among GeQ,( e ~'~kgle (the "Developer"), and the Town of Vail (the `Town"). WHEREAS, the Developer, as a condition of approval of the Temporary Certificate of Occupancy for 3 5' Y He fe < 0,, v,, tQ Q) Go i' icy J/~C-k /Z (address, legal description, and project number) wishes to enter into a Developer Improvement Agreement; and WHEREAS, the Developer is obligated to provide security or collateral sufficient in the judgement of the Town to make reasonable provisions for completion of certain improvements set forth in the attached estimated bid(s) in accordance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vail; and WHEREAS, the Developer wishes to provide collateral to guarantee performance of this Agreement, including completion of the all improvements referred to in this Agreement, by means of the following: The Developer agrees to establish a cash deposit account with the Town of Vail, as escrow agent, in the amount of $ C . 0, 0 J as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. NOW THEREFORE, in consideration of the following mutual covenants and agreements, the Developer and the Town agree as follows: 1. The Developer agrees, at its sole cost and expense, to furnish all equipment and materials necessary to perform and complete all improvements referred to in this Agreement. The Developer agrees to complete all improvements referred to in this Agreement on or before the _ day of y' - - O 2 20 . The Developer shall complete, in a good workmanlike manner, all improvements referred to in this Agreement, in accordance with all approved plans and specifications filed in the office of the Community Development Department of the Town of Vail, and to do all work incidental thereto according to and in compliance with the following: a. All said work shall be done under the inspection of, and to the satisfaction of, the Town Planner, the Town Engineer, the Town Building Official, or other official from the Town of Vail, as affected by special districts or service districts, as their respective interest may appear, and shall not be deemed F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 1 of 5 complete until approved and accepted as completed by the Community Development Department and Public Works Department of the Town of Vail. 2. To secure and guarantee performance of the obligations as set forth herein, the Developer agrees to provide collateral as follows: A cash deposit account with the Town of Vail, as escrow agent, in the amount of $ ~~~Sv~ • c,ci as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. 3. The Developer may at any time substitute the collateral originally set forth above for another form of security or collateral acceptable to the Town to guarantee the faithful completion of those improvements referred to herein in this Agreement and the performance of the terms of this Agreement. Such acceptance by the Town of alternative security or collateral shall be at the Town's sole discretion. 4. The Town shall not, nor shall any officer or employee thereof, be liable or responsible for any accident, loss or damage happening or occurring to the work specified in this Agreement prior to the completion and acceptance of the same, nor shall the Town, nor any officer or employee thereof, be liable for any persons or property injured by reason of the nature of said work, but all of said liabilities shall be and are hereby assumed by the Developer. The Developer hereby agrees to indemnify and hold harmless the Town, and any of its officers, agents and employees against any losses, claims, damages, or liabilities to which the Town or any of its officers, agents or employees may become subject to, insofar as any such losses, claims, damages or liabilities (or actions in respect thereof) arise out of or are based upon any performance by the Developer hereunder; and the Developer shall reimburse the Town for any and all legal or other expenses reasonably incurred by the Town in connection with investigating or defending any such loss, claim, damage, liability or action. This indemnity provision shall be in addition to any other liability which the Developer my have. 5. It is mutually agreed that the Developer may apply for and the Town may authorize a partial release of the collateral deposited with the Town for each category of improvement after the subject improvement is constructed in compliance with all plans and specifications as referenced hereunder and accepted by the Town. Under no condition shall the dollar amount of the collateral that is being held by the Town be reduced below the dollar amount necessary to complete all uncompleted improvements referred to in this Agreement. 6. If the Town determines, at its sole discretion, that any of the improvements referred to in this Agreement are not constructed in compliance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vail or not accepted by the Town as complete on or before the date set forth in Paragraph 1 of this Agreement, the Town may, but shall not be required to, draw upon the security referred to in this Agreement and complete the uncompleted improvements referred to in this Agreement. Pursuant to Section 12-11-8, Vail Town Code, the Temporary Certificate of Occupancy referred to in this Agreement may be revoked until all improvements referred to herein are completed by the Developer or the Town in accordance with this Agreement. F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash form at_5-16-2007.doc Page 2 of 5 If the costs of completing the uncompleted improvements referred to in this Agreement exceed the dollar amount of the deposit, the excess, together with interest at twelve percent (12%) per annum, shall be a lien against the property and may be collected by civil suit or may be certified to the treasurer of Eagle County to be collected in the same manner as delinquent ad valorem taxes levied against such property. If the Developer fails or refuses to complete the improvements referred to in this Agreement, such failure or refusal shall be considered a violation of Title 12 (Zoning Regulations), of the Vail Town Code, and the Developer shall be subject to penalties pursuant to Section 12-3-10 (Violations: Penalties) and Chapter 1-4 (General Penalty), of the Vail Town Code. 7. The Developer shall warranty the work and materials of all improvements referred to in this Agreement located on Town property or within a Town right-of-way, pursuant to Chapter 8-3, of the Vail Town Code, for a period of two years after the Town's acceptance of said improvements. 8. The parties hereto mutually agree that this Agreement may be amended from time to time, provided that such amendments be in writing and executed by all parties hereto. F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 3 of 5 Dated the day and year first above written. X A/11/2,~ Developer STATE OF COLORADO ) ) ss. COUNTY OF EAGLE ) The foregoing Developer Improvement Agreement wazm~~w me this Day of 20,21 by x Witness my hand and official seal. My commission expire0- :z &jQ / Notaryublic Town Planner STATE OF COLORADO ) )ss. COUNTY OF EAGLE ) The foregoing Develo er Improvement Agreement was acknowledged before me this _CC Day of~ 20 ~~by Witness my hand and official seal. My commission expires: (2~ (I 19, '2-b t ( `;'NOTAR-IN PIJ ~1• Notary- Public 'T F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 4 of 5 ATTACHED COPIES OF THE ESTIMATED BID(S) /S (D! 0 0 ) Y ~ F:\cdev\FORMS\Permits\Planning\Administrative_Actions\DIA cash format_5-16-2007.doc Page 5 of 5 J Town of Vail Department of Community Development 75 S. Frontage Road Vail, CO 81657 Name: ZoL~ 6"A'r'.' rs"' SI &-A'r Receipt No. /0(6 Address: 3 yy l3~r. u 2aQd Project: Bo7- 0191 Date _7 / /4 Please make checks payable to the TOWN OF VAIL Account No. Item No. Code # Cost Each Total 001 0000 314 1110 Address Maps ZA $5.00 * 001 0000 314 1110 Zoning Maps ZA $20.00 * 001 0000 319 4400 Custom Maps 001 0000.314 1112 Other Code Books CB 001 0000 314 1211 Blue Prints/M lar Cop Fees BF $7.00 * 001 0000 314 1111 Xerox Copies XC $0.25 * 001 0000 314 1111 Master Plan MS 001 0000 314 1111 Studies, Master Plans, etc. MS 001 0000 312 3000 Contractors License Fees CL 001 0000 312 3000 Contractors License Fees - RENEWAL CL 001 0000 240 3300 Developer Improvement Agreement Deposit D2-DEP10 AD 215-00 • co 001 0000 312 1000 Restaurant License fee TOV RL 001 0000 230 2000 Sec. Assess.-Restaurant Fee to Co.Dept.Rev. SA 110 0000 314 1115 Resale Commission MS Other - MS Other - MS Other - MS Other - MS Other - MS 001 0000 201 1000 Taxable ft_ 4.4% State - Tax payable TP 001 0000 310 1200 Taxable 4% Town - Retail Sales Tax T7 TOTAL: G2 sc~ • ~ * all items charged tax Comments: Cash Money Order # Check # 92 77s Received QG Credit Card: Visa/MC Last 4 CC #'s Auth Name on CC f/cdev/forms/admin/sales action form 2007 /5/06 Town of Vail * CUSTOMER RECEIPT Oper: AJANUSZ Type: F8 Drawer: 1 Date: 7/17/05 01 Receipt no: 10072 Customer Location Name Amount 2891 290 8U7-0192 J.DAYTON/6. AD AR-DEPOSITS $62500.00 JOHN DAYTON/6 SHAEFFER PERMIT007-0192 Tender detail CK CHECK 97795 $62500.00 Total tendered $62500.00 Total payment $6600.08 Trans date: 7/17/09 Time: 9:1:,:47 THANK YOU FOR YOUR PAYMENT!