Loading...
HomeMy WebLinkAboutB04-0281 PlansPROJECT DATA CO3 L ADDRESS v 501 N, FRONTAGE RD, WEST VAIL, CO ,JURISDICTION 1 2 ! SOLAR EXISTING BUILDING VAJL ZONING CLASSIFICATION R -1 CONSTRUCTION TYPE OCCUPANCY HEIGHT 28'-19'+/- NQ STORIES 3 GROSS BUILDING AREA 16,038 + /- SQ, FT, ALLOWABLE AREA OCCUPANT LOAD ! a ! 1 • Ak CONSTRUCTION TYPE OCCUPANCY HEIGHT EQUIPMENT ROOM HEIGHT ANTENNAS 10' -6" ABOVE ROOF NO. STORIES GROSS BUILDING AREA TOTAL AREA ALLOWABLE AREA OCCUPANT LOAD rA 411 k ]AWTA SM a ML 1. IT 15 THE CONTRACTORv RESPONSIBLITY TO VISIT THE SITE AND NOTIFY THE ARCHITECT OF ANY DISCREPENCIES BETWEEN THE DOCUMENTS AND ACTUAL CONDITIONS. 2. FOR INFORMATION REGARDING THIS SITE, CONTACT: JERRY BELL, PM2, VERIZON WIRELESS AT 303- 534- fOW - 1. 3. CONTRACTOR TO COORDINATE CONSTRUCTION WITH THE BUILDING MANAGER IN ORDER TO IMPACT BUILDING USER AS LITTLE AS POSSIBLE. 4. ALL INTERRUPTED SYSTEMS TO BE RESTORED TO ORIGINAL CONDITION AND OPERATION. 5. ALL DEMOLISHED ITEMS ARE TO BE REMOVED COMPLETELY FROM THE SITE. 6. PATCH AND REPAIR ANY DAMAGED ITEMS TO MATCH ORIGINAL CONDITIONS. - 1. CONTRACTOR TO PROVIDE 2" DIA. CONDUIT FROM EQUIPMENT ROOM TO TELEPHONE ROOM FOR TELCO. COORDINATE LOCATION WITH LARRY DAHL. S Ah P.O. BOX 19.707 IRVINE, CA 92623 -9707 I hik ummium Nth. Im= 0 layme) s Mi ON SITE IMPROVEMENTS FOR A TELEPHONE CELL SITE FOR VERIZON WIRELESS, KNOWN AS "CO3- VAIL.," ALL WORK INCLUDES MOVING AND RAISING (4) EXISTING WHIP ANTENNAS, INSTALLING (8) 4' -0" PANEL ANTENNAS IN (1) EXISTING AND (1) NEW FALSE CHIMNEY, AND RUNNING ALL REQUIRED POWER AND COAXIAL CABLE FROM THE EQUIPMENT ROOM TO THE ANTENNAS. a , 7 = 0 THIS SPACE IS RESERVED FOR SIGNATURES OF INVOLVED PARTIES TO INDICATE THAT THEY HAVE REVIEWED THE ACCOMPANYING DOCUMENTS AND HAVE APPROVED THEM, CHANGES INITIATED AFTER APPROVALS HAVE BEEN GIVEN MAY RESULT IN ADDITIONAL DESIGN OR CONSTRUCTION COSTS, Owner date Jerry Bell, PM2 - Project Manager, Verizon Wireless date COAX LENGTHS M � (E) WHIP ANTENNAS ON TRIANGLE MOUNT (E) ROOFTOP BOX W/ (4) PANEL ANTENNAS MOUNTED ON OUTSIDE 1 NEW LOCATION OF (E) WHIP ANTENNAS. ANTENNA MOUNTS ATTACHED TO OUTSIDE OF WALL AND S.O. ANTENNA RADOME TO BE `i' -O" ABOVE ROOF. MAINTAIN (E) SPACING. T.O. (E) ANTENNAS 440-1 1 - '1111 T.O. ANTENNAS Vr 38' -4° TO. (E) R Vr 33' -"t" (825239 (E) MICROWAVE C (E) EQUIPMENT SHELTER ;, '1= ---1 NEW FALSE CHIMNEY TO MATC CHIMNEY ON WEST WALL. TOP PORTION TO BE fir- TRANSPARENT MATERIAL AND HOUSE (4) PANEL / ANTENNAS / •PORTION OF RETAINING WALL REMOVED FOR CLARITY* a 1 /8 " = 1' -o" (E) FALSE CHIMNEY TO BE COMPLETELY REMOVED AND NEW LARGER CHIMNEY TO BE BUILT. (E) MW DISHES TO REMAIN IN W (E) FALSE CHIMNEY TO BE EMOVED AND NEW rY TO BE BUILT. 70 REMAIN IN TION. TOP PORTION 3PARENT AS WELL )NT OF MW DISHES. NEW T.O._A (E) ROOFTOP BOX W/ 44 " -I" (82b @8') (4) PANEL ANTENNAS Art/$ n.r =r, roi iv Iran -.r- I(f- 30� ,./—(E) VERTICAL CABLE CHASE 4'- e(�� lodI, ' �--- NEW LOCATION OF (E) WHIP ANTENNAS. ----/ I ANTENNA MOUNT$ ATTACHED TO OUTSIDE OF WALL. B.O. ANTENNA RADOME TO BE .�,, �" ABOVE ROOF. MAINTAIN (E) 000 SPACING. 0000 0000' 0000 (P C''� ---- (E) WHIP ANTENNAS ON 0000 TRIANGLE MOUNT ' i y ' r-1 r-r r >/, •/' I n r' 0000 ---ra7 !! II Lj if -0 It ""'"► rah 11 1 /'~ � 00000 ! � � rah •�" SOLAR VAIL BUILDING 00000 501 OF (E) WH A NTENNAS NEW ROOFTOP CABLE 00000 501 N. FRONTAGE ROAD WEST TRAY � ,.s '" VAIL, CO 5E MOVED TO 5ACK OF AN R A15ED SO THAT ''"'"' .•f RADOME 15 ABOVE ROOF T- I t/ 000" (2) (E) PANEL (E) FALSE CHIMNEY TO BE pK+ ANTENNAS COMPLETELY REMOVED AND NEW (E) ROOFTOP BOX W/ LAMER CHIMNEY TO BE BUILT. p (4) PANEL ANTENNAS (E) MW DISHES TO REMAIN M MOUNTED ON OUTSIDE ORIGINAL LOCATION. TOP PORTION TO BE RF TRANSPARENT AS WELL (E) ROOFTOP AS AREA IN FRONT OF MW DISHES. BOX \I NEW FALSE CHIMNEY TO MATCH CHIMNEY ON WEST WALL. TOP PORTION TO BE RF- TRANSPARENT MATERIAL A11- I IN I-- 1 r 4 - - - NEW FALSE CHIMNEY TO MATCH CHIMNEY ON WEST WALL. TOP PORTION TO SE RF— TRANSPARENT MATERIAL AND HOUSE (4) PANEL ANTENNAS RE: STRUCT. � r �ziMur (E) EQUIPMENT SHELTER . /1 WEST ELEVATION �n� ve".r -o• (4) NEW PANEL ANTENNAS MOUNTED TO 2 —%" PIPES ATTACHED TO "LEVEL 2" JOISTS SEE STRUCT. FOR JOIST LAYOUT FIBERGLASS TS THIS CORNER ONLY RE: STRUCT. NORTH WEST CHIMNEY ALL COMPONENTS OF CHIMNEY TO BE FIRE RETARDANT MATERIAL. SIDING TO MATCH STYLE AND BE FIRE RESISTANT (HARDIE OR SIMILAR). RE: STRUCT. <C W EDGE OF WALL SHEATHING LVI FA '4 W SHEATHING FiBEW -sLASS NORTH E AST CHIMNEY il PAINT TOP TRIM TO MATCH (E) TRIM (E) C44IMNEY TO BE COMPLETELY REMOVED AND NEW CHIMNEY BUILT AT NAME LOCATION. (E) MICROWAVE DISHES. LOCATE OPENINGS IN CHIMNEY TO LJI. W/ DISHES. OPENINGS TO BE COVEREI W/ FIBERGLASS PANEL TO MATCH SIDING. CONTRACTOR TO VERIFY MW LOCATION AND NOTIFY ARCHITECT OF ANY CONFLICTS. APPLY "HARDIE" FIRE RETARDANT SIDING OR EQUAL OVER SHEATHING MATCH STYLE AND SIZE. ALIGN W/ (E) SIDING. PAINT TO MATCH (E) BLDG. PAINT TOP TRIM TO MATCH (E) TRIM. (4) NEW PANEL ANTENNAS MOUNTED TO 2 —%" PIPES ATTACHED TO "LEVEL 2" JOISTS SEE STRUCT. FOR JOIST LAYOUT 1/2" =1' -0" SHT. MTL. FIBERGLASS TS THIS RISER RATED COAX. CORNER ONLY CABLES RE: STRUCT. 16" LADDER RUNGS SPACED AS READ. 1=1126 UNISTRUT PLATE FITTING OR EQUIV. AS REQD. P2012A UNISTRUT OR EQUIV. W/ HILTI BOLTS AS READ. NNIN ICI 6 " SIDE RAILS EA. SIDE HOLD DOWN CLAMPS EA. SIDE P1000 CONC. PAVER ON °V BUILDING; FELT - I• MEMBRA •I ol RACEWAY DEPICTED •— :. r► «: CABLE TRAY 1 1/2 "■ 1'_O" ._Ni /1 WEST CHIMNEY F- Z wo MW D W V) 0. - >1 - '.,. �, P �� iE �i 0�: Z 00 �- 0 ZO 0 W Ul - Q� V) a. 0 to F, _,J W W0<UJW 0 w 3: W ZMa W RUJ = W 0 5 (r) 0 ,0< ,0 0- 0 0 o x =) Z N 00- V W >_ w Z W , < (J) qw(n 0: W W 0 E: U. :Z X ,_ WoOD3: _J WSW ' W, : W Wf_ Z UJ W WMZ I— =) Q D W o _J �7 M W 0 F- W Z Z C W W a. Z :2 00 OW (.)=W f.-WX < W1. O,Zq�: 012 In 0W M " W W 'a 0� 2 " � 6 W,: W W2 ' �- = C, Zwo - 0 a W Q. i ,c) �w ZV) '0 0 , C Z L, Z WW WW 5) 0� W _J M d �05 M ,0 U, �gz �wv)Q(n W ZO C> go W M < LLJ F- D 0 F Z 0 0�Oujw� 0QZM:EM 08 :>>=> H0 f Ld Z 0Z 1 T L, :j mo r2L­J t ,00�� 5W 0 fu= 13: >- 0 :c Z <§O M Z L ' . L, Oa ( n =)Zo(> 3:0 a < < La N Ld O� Z M 0 Q: 0-(j4 MiE 9 �i ow m_jw Z0:3 =) .�a (Y W Z . :gu� =>=)Z < Z 0 0::) (L) 0:: 0 Fl Z o HOZ W - XM t. 0- _0 0 ZZ Z Z 0 E 05 L ,WZ LL 0 LJ 0 Ld I- 1< M 3:2 Z 1 LJ - 1 Z 3: 0 0 a. LLJ > __J0 ir Z O<C)(/> ZLU _ 40 < 110 U _ w (f) Q) 0 (/)UJ6 Z. D 0 � Z . - OU500 t; N tZ D RL , < 0 0 n In 0 ZZ 0 < Lb 0 U: D U) Or 1 0-8 D 5E Z D OZ L'i Z CL < o z o w 0 OD w I— Z , 65 U . 00 5 5 < !Eom w?,) wo L .. a-r z wnt= o 0:6� (3 i+ U_ Z 0 to 8 ; i �E wo�d 3: < W 0 0 �Z Z o :-:> p OPO 005w wc) 6 o I.-OZ (n 0: �icM 0 , W W O W, Z & o 1 o af .0 M RON 0 0 X W =, , o L ,no 0 O W N N Z 0 t­ , Z=8 EL CCD 0 < 0:� M a: (L W Ld lox¢ @ FRAMING NOTES: 1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO START OF WORK. 2. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCH/ENG. IMMEDIDATELY FOR ADDITIONAL DIRECTION. 3. THESE PRANIN(55 SHALL BE COORDINATED WITH THE ARCH PLANS. 5. FIBER 6LA55 PANEL. 50REN AT ANTENNAS: !/2" F.B. PER ARCH. ATTACH TO FRAMING vil 5 46"4h x 3" LAG BOLTS @ 12" oc. IN PRE-DRILLED HOLES. (USE STANDARD NA5HER5, TYP) n1 1 PfInP I M/Fl 2x SILL PLATE YV HILTI .158 X-ZF 5HOTFIN5 @ e0 O.C. SCALE : 1/2 (E) CONC WALL I IQ Q) X (I 4x6 BEAM N/ SIMPSON HUC4 HANGER EA END 4x8 BEAJ TYPICAL (5 PLACES) y 5IMP50N 5T&256 STRAP FROM TYP BEAM TO BEAM (2 PLACES) Q� TYP TYF 5IMP50N HU HANGER EA END, TYP 5IMP50N ST6256 STRAP FROM BEAM TO BEAM (2 PLACES) 5 -2 TYP L5x3x!/4 2x& J015T 4x6 BEAM W 5IMP50N ­HUC+AN6M FA END T V JUE T R I NOTE: TYPICAL PLYWOOD SHEAR PANEL: 3 /6 "" CVX FLYI`1001? P.I.:20/0 ED&E NAILING (EN), e>d @ 6" O.C. FIELD NAILING (F.N.): 5d @ 1:2" O.C. BLOCK ALL E1?6E5 SIMP50N H2 TIE @ 12" O.C., TYP EXTENT OF 1/2" THICK FIBER6LA55 SHEATHING (2 51VE5) AS 5HOIAIN COORDINATE N/ ARCH I ZP4X r`1CCJ- - NOTE: TUBE COLUMN BY EXTRW5TRON61AIELL ROOF SHEATHING: ek" THICK COX P'LY'WOOD f1l:=52/16 SUPPLIER SHALL DESt&N-AND -BOU OAR'r NAILIN6 BN): 10d -0 --&" -0. . STRUCTURAL FIBER6LA55 P05T EDGE - NAILING (E.N.): 10d @ 6" O.C. (I PLACE) FIELD NAILIN6 (FN.)-. lod @ 12" 0-.0. OF PLAN C3) 2x BLOCKINC, W (1) 5IMP50N A54 ANCHOR PER BLK TO PLATE 2x6 HEM-FIR STUDS @ 16" O.C. LAP J015T A5V AND BLK'& BLN K/ 3-16d NAILS 2x6 HEM-FIR 5TUL @ 16" O.C. 2x BLOCKING, TYP 2x P.T.D.F. PLATE K/ $/V(P (A56) THRDV R005 IN HILTI HIT HY-150 ANCHORS @ 16" O.C. 2x LEDGER, TYP (E) CONC WALL 4x4 FULL HEIGHT P05T N/ e/ "'4> (A36) THRD'D ROV5 IN HILTI HIT HY-150 ANCHORS @ 12" O.C. 2x BLK'& TYP. TYP (E) CONC. WALL STEEL FRAME/ (2 PLACE5) LEVEL l +11 a " - T - RODS ,L3x3x!4 .DIAGONAL 2X& LEDGER 4 A30 +*ZEAT�-ED IN 14IL 141T W-150 AVRA"ORS DL. EA KAY VV Y4 FILLET NTO,00t�-RE-TE) YZ10 TO AT., TYP -4 4. 4 SCALE: 1/2"=1'-O" GENERAL REOTTMIEMENTS CONTINUED 14. Where no details are shown, constructionshall conform to similar work on the project. Typical details iway not necessarily be cut on the plans but apply unless otherwise noted. Where discrepancies occur between plans, details, elevations or specifications, the contractor sliall assume the greater requirement governs and coordinate the work as required. 15. The contractor shall be responsible for verification of all dimensions and details with the architectu drawings prior to construction. All discrepancies must be resolved prior to fabrication or installation. GENERAL NOTES GOVERNING -IC Code- - C4-of Vail, Colorado 1997 JJuilonnBuilding Code Win& -SO,4aph 4 00r. 400 P-SF (iAus SRow, DnitiRg -wbere AWhcAlo) 4x4 D.F. P05T this project has been based on the following code or specification, as appropriate, for each 4istod 4natetial. Wood .............................. Structural Steel ............ ............ ........ AISC Specifications for Structural Steel - 43ttilding& (A 8D -or FULL HT. 4x4 P05T K/ 3 /W'4' (A56) THRD'0 RODS IN HILTI HIT HY-150 ADH. ANCHORS @ 12" O.C. (6V2" EMEBED INTO CONC) 2x4 INFILL STUD BETWEEN LEVELS TO FRAME OPENIN65, TYPICAL FULL HEIGHT 4x4 POST EACH CORNER (4 TOTAL) FULL HEIGHT 4X4 P05T EACH CORNER (4 TOTAL) NOTE: I. FLOOR SHEATHING: %" THICK UNDERLAYMENT r5RAVE PLYWOOD (67ROLIP 2) BOUNDARY NAILING (5N): 10d @ 6' O.C. 117CE1VA1L1N& (EN.): 10d @ FIELD NAILING (FN): 10d -@ 12" O.C. USE ­RtWv SHANK - OR SCREN I - GLUE - 1r - FRAMN& 2. CONTRACTOR SHALL RECONSTRUCT OPENIN65 TOR E­INSTALL ­EX15TINC, - 5ATELLITE - V1544ES AND ANTENNA - MATCH T:W INS LOCATIONS IN PLAN AND ELEVATION. 'EX19TM--OFE-NNr;75 - 514ALL OTHERWISE, LVqERt"S REPLACED IN-KIND. 5. CONTRACTOR SHALL VERIFY LOCATIONS OF NEN CHIMNEYS KITH ARCHICTI)RAL DRANIN&S. THE EXt!5TIN6_CHIMNEY:5HALL_BE DEMOLISHED AND REPLACED AS 5HONN IN THESE DRANIN65. 4. REUSE -EXIST IN& HARDWARE FROM HN5W AG 55 DOOR A10 - !XV.V!ER5 5. DESIGN ASSUMES EX15TIN6 MICROWAVE 015HE5 ARE MOUNTED DIRECTLY TO - THE - EX15TIN6 Gil 'TCONDITION IS - 0T+T"S1;,-rOWACT ARCHITECT. (b. MATCH DIMENSIONS AND A.DLATION5 -OF :EA5TJN& -OFENN66. 7. ALL TIMBER AND PLYWOOD SHALL BE 'FIRE RETARD-ENT' MATERIAL. FULL HT. 4x4 -POST Yql 5 /4'4 1A ) THR D'D RODS -1A1 M I OT W-150 A -ANCHOR5 12 O.C_W/2" EMEBED INTOZONG) 2x4 INFILL STUD BETWEEN L - B - T B -OT�MEOFENIN65, TYPICAL -CENERA-L REOUfREMENTS 1. Use of lilcse -drawings +Ovtile-crnwrxst�vction - 0f - tins , PMtct - Caxries - %qti1-such use implicit-acceptance following Jr, ra, graphs. 2. The Contractor-shall be solely responsible-fbr supervising and directing - the Work, using the Contractor's best skill and attention. The Contractor shall be solely responsible for and have control over construction means, methods, techniques, sequences and procedures and for coordinating all portions of the Work under the contract. The Contractor shall be responsible for inspection of portions of Work already performed under this contract to deterniftic that such portions are in proper condition to receive subsequent Work. 3. The - Contractor shall be responsible for initiating, maintaining, and supervising all safety precautions and programs in connection with the performance of the Contract. The Contractor shall give notices and comply - with all applicable laws, ordinances, rules, regulations and lawful orders of public authorities especially OSHA bearing on safety of persons oTTmpmty - or - their - prutection from - damage, injury - or loss. The Contractor shall not load or permit any part of the construction site or construction on - thesitc - to - be loaded so as to endanger its safety. 4. - in - the event the encounters on she material - reasonably - believed to be asbestos or polychlorinated biphenyl (PCB) or other known hazardous material which bas - not - been - reri'dere- d - the Contractor shall immediately step Work in the area affected and report the condition to the Owner in writing. The Work in the affected areashall nollhereafter resumed except by written agreement of the Owner and Contractor if in fact the material is hazardous and has not been rendered liarnitess. The"Work in affected area sliall be resumed in the absence of asbestos or polychlorinated biphenyl, (PCB), or other known hazardous material, or when it has been rendered liamiless by written agreement of the Owner and Contractor. 5. In no case shall structural alterations or work affecting a structural member be made, -06100:R0 , CA4UyEWRV- unless approved by CSD in writing. A, Conforin to the following: 6. Contractor shall field verify all dimensions and existing conditions and notify CSD of I- ANSI/B 1 -L Bolts and Screws any discrepancies before proceeding with the Work. 2. ASTM A307 - Bolts 3. AWPA Book of Standards 7. Submittals sliall be sent to CSD based on the following procedure: 4. American Softwood Lumber Standard, PS 20-70. Shop Drawings - Submit a reproducible set and one set of prints for shop drawings 5. fed. Spec. FF-N-105B, Nails. specifically requested to be submitted in subsequent paragraphs of these notes Tor the various materials to CSD after review and approval by the Contractor, The B. - Use the following materials: reproducible Will be returned. 1. Lumber shall conform to Vol. Product Std. PS 20-70 with moisture content less 9 JaisL- _- nluinber-.slieatl)ingshall-occnr-over,mWoj-U unless approved aiid madhedlumber is used, in which case each piece sb0bear on at least two supports. Stagger all plywood common wire nails or approved plywood nails With 3/9" edge distance. Use 2x4 Tlatblocking of approved plywood cleats at interior supported -panel edges where indicated. 1 0. All sheathing and nailing s1fall inspected by the localbuilding official prior to the placing of coverage. D. Glued Laminated Wood 1. All fabrication and workmanship shall conform to U.B.C. Chapter 23, Division 1, ANSI/AITC Standard Al 90.1 and ASTM D 3737, A.I.T.C. 117, and the current edition of the Standard Specifications for Structural Glued Laminated Douglas Fir (Coast Region) Lumber by the West Coast Lumbermen's Association and the current edition of Timber Construction. 2, All work shall be done in the shop of an approved Type I licensed fabricator. 3. All laminations shall be 1-1/2" thick and of the width shown on the structural drawings. All laminations shall be parallel to the bottom edge of the beam. 4. All glued laminated members shall be Douglas Fir, Combination 24F with waterproof resorcinol or phenol resorcinol glue conforming to the Federal Specifications MIL-A-397B-B. Core laminations may be hem fir. Use combination 24F-V4 or 24F-V5 for simply supported beams and combination 24F-V8 or 24F-V10 for cantilevered beams. 5. A certificate of inspection for each Glu-Lam beam from an approved testing agency shall be submitted to and approved by the local Building Department and by the Engineer prior to erection. 6. All Glue Laminated wood beams shall be cambered as noted on the structural drawings. 8. The Contractor shall defend and indeninify and hold Computerized Structural Design, Inc . "), - their - agents and - emplo ves, - all costs, damages, claims, actions and proceedings (including legal fees associated with threatened or actual - lawsuits, - mediations and arbitrations) of - nature arising out of the performance of the Work, and any modifications thereto, under the teens and conditions of the Contract or arising out of, but not limited to, collapse, failure, shifting, leaning, misaligmuent, tw=isting, bending, or falling of the Work or any portion of the - work whether or not said occurrence is a result of negligence on the part of the Contractor, so that the indemnity against said claims is in the nature of a strict obligation with the one exception of proved negligence (in a court of competent jurisdiction) that CSD committed a design error which caused the collapse, failure, shifting, leaning, misalignment, twisting, bending or falling of the Work. Owner and Contractor acknowledge that CSD has no responsibility for the manner and means of construction, including bracing, and that CSD may rely on this paragraph. The indemnified claims include, without limitation, any damage to tangible property or loss of use thereof and any injury to persons including sickness, disease and death, and any fines, penalties, wages lost or cost of corrective measures sustained as a result of the Contractor's failure to comply with O.S.H.A. or any other applicable rules or regulations. 9. The Contractor shall conform to all applicable local, state and federal regulations, 10. The General Notes and Drawings contain performance standards, tolerances and material specification. It is the responsibility of die Contractor to provide a constructed-product-in conformance with these criteria. If sonic.portion of the constructed product is not in compliance with these criteria, the Contractor is r�--sponsible4o-r-epair-or.reinov-e-and replace the faulty construction at no cost to the Owner. The proposed repair is subject to the written approval of the Engineer and the 0m+c-r- and-must restore the constructed product to perfortil its intended purpose. - Unlessaft -activityordutyis specifically identified as being performed by the Project Structural Engineer of R=ordi it - wiil - not - be - perfmn , ed - by - C - S - D. ltivill curers. The only exception to-thisis of bottom chord stability plates for joists - adjaceirt to - 12. - CSD will analyze repairs, replacements or modifications to anchor rods as -required by OSHA subpart R. However, requests for these assessments inustbe initiated by the "Controlliug Contractor" or the "Steel Erector", not CSD, 13. structural drawings illustrate the structural work and are part of a -coniplementary - set of drawings includingarchitectural, mechanical, electrical, plumbing, civil, demolition, and process drawings. The contractor is responsible, for . coordinating the Nvork of other disciplines into .the structural work. than 19% when delivered to job. CSD will: 2. Blocking, cants and plates in contact with foundations, roof or subject to moisture sliall be pressure treated per AWPA Standard C2. a) review submittal information solely for conformance with the design concept 3. Studs, blocking, plates (Hem Fir) ............... .............. Stud grade. b) approve or take other appropriate action 4. - Wood Structurdl shall be identified by a registered stamp of the American c) stamp & return submittals to Contractor for appropriate distribution or resubmittal. Plywood Association, and includes veneer plywood, and matformed panels such as oriented strand board (OSB) and waferboard. The CSD of submittals will be made for the limited purposes and are subject 5. Wood Structural Panels for floor sheathing shall be underlayment grade. All the limitations and disclaimers set forth in the Contract Documents, these General wood structural panels shall be bonded by intermediate or exterior glue. All wood Notes, and the CSD Proposal to our client. CSD review does not involve or include: structural panels shall conform to U.S. product standard PS 1 latest edition. a) review of submittal dimensions and quantifies. 6. All wood structural panels shall be 5 -ply, Structural TI, CD, CC, or OSJ3 and shall b) acceptance or assumption of any responsibility to review, analyze or evaluate any be grade marked. Use wood structural pariel nails same gage as common wire submittals including shop drawings provided to CSD, or acceptance or assumption nails with lengths at least equal to one-half length of common nail required, plus of any part of Contractor's responsibilities -which include the Contractor's wood structural panel thickness. responsibilities to review and approve of submittals, whether or not the CSD review 7. Nails shall be common. Nailing shall be per 23 of the Uniform Building Code was made prior to the review and approval of the Contractor. u.n.o. on the plans or details. Holes for nails shall be pre-drilled for nails larger in c) review, evaluation or approval of project safety precautions or safety training. 8. diameter than 16d or where driving causes splitting. All metal connectors shall be Simpson Strong-Tie (galvanized) connectors (or d) review, evaluation or approval of construction means, methods, techniques, approved equal). The nails for these connectors shall be joist hanger nails as procedures or sequences. manufactured by the Simpson Company. 9. - Shot pins for interior, non-shear walls sliall'beHilti (or approved equal) type and -CSD approval of a specific item does not include or indicate or constitute approval of a ICBO approved with steel washers, or approved equal. group or an assembly of which the item is a component. C. Contractor slWl: The Contractor must notify CSD, in writing, relative to any deviation from the Contract 'l. Install all rough, caipentry including cants, plates, blocking, furring, mailers as 'Documents, -which appears in the shop drawings. Approval of the submittal containing indicated. such deviation does not constitute approval of the deviation. Approval or rejection of - 2. - All bolt'h6les wood shall - be 4/16-inch maximum larger than the bolt size. the deviation Will only be provided by CSD in a separate written communication to the Washers shall -be placed under-all nuts and- lie-ads of all bolts and lag screws. Contractor. - 3. - Installbolts With plates or washers between member and - head and nut. 4. Install lag screws as follows: Drill -lead -holeof-diameter equal to -50 percent of In the event that CSD reviews submittals (as a-courtesy to the Contractor to reduce the shank diameter and oT leng(li equal to length of screw and drill a clearance time prior to the start of fabrication) such submittals having not first been reviewed and -hole equal -to shank -diameter and-oflength equal to the length of the unthreaded 'Install approved by the Contractor, such CSD review shall not relieve the Contractor of his - 5. sbafik. lag screw turning With wrench, responsibility to perform review and approve all such submittals, nor Will it create Do-not harnmer-44g screws -of screws-into holes. - responsibility -orliability.Dn the part of -CSD -as-to the-contents, accuracy or 6. - Framing members-sliall-not-be notched, dapped -or otherwise cut or reduced in -completeness of such shop drawings except as may be specifically described in the size unless specifically - detailed or approved. --ACoutrwA-Docwn eats, these C4cneriIN6tes,-mW-tlio Submittal Tmsmittal. Contractor -is 7. -Providc-solid blocking-between-joists and rafters-at-allpoints of support. solely responsible for review and approval of shop drawinas and other submittals, and Provide approved cross-bddgiiig bet-ween at 3%0" o.c.' (ma x)" and -Cmitraetor4s solel oi -€ alI requirem of-the-workof flue contractor as -between rafters at 10'-0 "-o.c.4mm.). provided for in the Contract Documents or on the agreement with the Owner. S. "Posts and multiple studs at upper levels §101 have matching and aligned posts and -multiple studs at levels unless otherwise noted. Tight fitting, solid In the event that the Contractor chooses, at its own discretion, to create shop drawings - blocking shallbe provided betweenlevels under all such posts and multiple for use as erection drawings by using - CSD prepared Drawings or electronic files, .scuds. Blocking- shall equal-area.of post.2bove,and below and.aligned Contractor-do-es so-at its own -risk. No.guarmtee -vvlilsoeNerisgiNciibyCSDtliatCSD vertically. Drawings arc suitable for such use, 9 JaisL- _- nluinber-.slieatl)ingshall-occnr-over,mWoj-U unless approved aiid madhedlumber is used, in which case each piece sb0bear on at least two supports. Stagger all plywood common wire nails or approved plywood nails With 3/9" edge distance. Use 2x4 Tlatblocking of approved plywood cleats at interior supported -panel edges where indicated. 1 0. All sheathing and nailing s1fall inspected by the localbuilding official prior to the placing of coverage. D. Glued Laminated Wood 1. All fabrication and workmanship shall conform to U.B.C. Chapter 23, Division 1, ANSI/AITC Standard Al 90.1 and ASTM D 3737, A.I.T.C. 117, and the current edition of the Standard Specifications for Structural Glued Laminated Douglas Fir (Coast Region) Lumber by the West Coast Lumbermen's Association and the current edition of Timber Construction. 2, All work shall be done in the shop of an approved Type I licensed fabricator. 3. All laminations shall be 1-1/2" thick and of the width shown on the structural drawings. All laminations shall be parallel to the bottom edge of the beam. 4. All glued laminated members shall be Douglas Fir, Combination 24F with waterproof resorcinol or phenol resorcinol glue conforming to the Federal Specifications MIL-A-397B-B. Core laminations may be hem fir. Use combination 24F-V4 or 24F-V5 for simply supported beams and combination 24F-V8 or 24F-V10 for cantilevered beams. 5. A certificate of inspection for each Glu-Lam beam from an approved testing agency shall be submitted to and approved by the local Building Department and by the Engineer prior to erection. 6. All Glue Laminated wood beams shall be cambered as noted on the structural drawings. 8. The Contractor shall defend and indeninify and hold Computerized Structural Design, Inc . "), - their - agents and - emplo ves, - all costs, damages, claims, actions and proceedings (including legal fees associated with threatened or actual - lawsuits, - mediations and arbitrations) of - nature arising out of the performance of the Work, and any modifications thereto, under the teens and conditions of the Contract or arising out of, but not limited to, collapse, failure, shifting, leaning, misaligmuent, tw=isting, bending, or falling of the Work or any portion of the - work whether or not said occurrence is a result of negligence on the part of the Contractor, so that the indemnity against said claims is in the nature of a strict obligation with the one exception of proved negligence (in a court of competent jurisdiction) that CSD committed a design error which caused the collapse, failure, shifting, leaning, misalignment, twisting, bending or falling of the Work. Owner and Contractor acknowledge that CSD has no responsibility for the manner and means of construction, including bracing, and that CSD may rely on this paragraph. The indemnified claims include, without limitation, any damage to tangible property or loss of use thereof and any injury to persons including sickness, disease and death, and any fines, penalties, wages lost or cost of corrective measures sustained as a result of the Contractor's failure to comply with O.S.H.A. or any other applicable rules or regulations. 9. The Contractor shall conform to all applicable local, state and federal regulations, 10. The General Notes and Drawings contain performance standards, tolerances and material specification. It is the responsibility of die Contractor to provide a constructed-product-in conformance with these criteria. If sonic.portion of the constructed product is not in compliance with these criteria, the Contractor is r�--sponsible4o-r-epair-or.reinov-e-and replace the faulty construction at no cost to the Owner. The proposed repair is subject to the written approval of the Engineer and the 0m+c-r- and-must restore the constructed product to perfortil its intended purpose. - Unlessaft -activityordutyis specifically identified as being performed by the Project Structural Engineer of R=ordi it - wiil - not - be - perfmn , ed - by - C - S - D. ltivill curers. The only exception to-thisis of bottom chord stability plates for joists - adjaceirt to - 12. - CSD will analyze repairs, replacements or modifications to anchor rods as -required by OSHA subpart R. However, requests for these assessments inustbe initiated by the "Controlliug Contractor" or the "Steel Erector", not CSD, 13. structural drawings illustrate the structural work and are part of a -coniplementary - set of drawings includingarchitectural, mechanical, electrical, plumbing, civil, demolition, and process drawings. The contractor is responsible, for . coordinating the Nvork of other disciplines into .the structural work. h rwo mew O 1 > - Wh z o f - �a z owoa 0��� a W�w�w waw�H �Czz Q:!r W w J n o ww t� Q Qwv s i Z WZma T0, 1 0 _>j ` hvm�Q x o .- w �aU) c5�cn w v'nwo Q x 4 h °¢ O t'Mww ao oww (n r -iIt a L-L, oww- -w o c, u w t;0 j!Ra wh "zzUn= Ew Q wiz c o o O¢-j vw0Jz r F J ahe �hmzwo w ww, d Q � of-wa W�c 0>-ZOW gZ Q J Q z �QZt�li =,e ww�w Cw ° o J �, ZxMLlw Q a %, av_aoQ°-W 0 wt zu W -0 �� ° ?( �ao w JVJ ((y mw 1_QJ > =m s� I= ° Q�o r hu' w ° WOE ° 5or O ?CS 00Zm- Mm zF w 000 F- a. m00 rr a W w 0 J Z a�L^w o?W mo h=WJ W W o o �UIn 0 ' w rc --� "+ oozco Q� 0 �-_ Q aM "vQZ 0 c3 z °w � W W' uw =Z hhh s olxaE mzco a omo zzz`t ° w �m oW o < z zz Z V dOwz C O W L , ff/ m h {- NWZ o0Zo htnw� a O w w rwW 0�z a<Zw O < U- wU) va Oo�'z o 04 °s mb w ` r , a cn �� a w -0 O O ooam & Z o Z h N w'_ r=W o <zo `°a � n � ¢� 2 �oo� 0 J °aQ=> �>° aw >a w x Q iR z 0 0 w °0 I-Q00- W 0 z r o2 z WZ om t w a a0:: = �v� 3 u U U. z V {7 N O zd t- ¢o °o c? z rn t' <** o =)U- 0 r- zo 8 F Q (J t�a5cn o 0 81 O voz < cn U^ N z�v>- rr � e t a t-- WOSlO- � Q WO 0 0 o m til > 0oa P {- z�� � Wh 51MP5ON H2 TIE 2x BLK'G WI (3) 10d / BLK 2x J015T -5EE PLAN 2x BLK'C7 2X STUD WALL DBL 2x PLATE SHEAR PANEL -SEE ELEVATION WON SCALE : I " =i' -o"" /=I iAI A I " 2x4 HEM -FIR NO I SILL PLATE > X -ZF � 8" 00. To WT, TYI i TYP. 51DE OF WT KWIK BOLT II 'ER ANGLE TO CON gCHOR5 TOTAL) C kl i B.N. 2x RIM J015T W/ SIMP50N A54 ANCHORS @ I6 O.C. To PLATE IDE OF WT W1 R5 TO (E) CONC FULL HEIGHT P05T SEE PLAN 2x 5TUD FOR OPENIN6-5EE ARCH 2x SILI 2x Jol: TO POE SECTION SCALE : I"=I' -O" BEAM I .., . „.....,. ..- 2x BLK'G W/ (1) 51MP50N A54 ANCHOR PER BLK TO PLATE L3 W /4 FILLET WELD TO TOP F OF WT EA END 2x JO15T -5EE PLAN 2x PLATE Wf HILTI .135 X -ZF 5HOTPIN5 @ 8” O..0 To WT PLYWOOD SHEAR PANEL SEE PLAN 2x STUD F SEE ARCH �- E.N. WT STRUT -SEE ELEVATION SCALE : I "= I' -O" FULL HEIGHT -SEE PLAN 31MP5ON CORNER STRAP 3EE PLAN Nollmim 50ALE : I "' =I' -0n STUD OR P05T BEYOND --� 2x BLK "G @ W/ 3 -1041 PE 2x JOI5T -5EE PLAN 2x SILL PLATE INTERRUPT AT POST ml BEAM -5EE PLAN NOTE: NOTCH PLYWOOD AROUND CORNER POSTS. SECTION SCALE: I " =I' -O" STUD OR P05T BEYOND -� 2x .JOIST SEE PLAT` 2x SILL PLATE INTERRUPT AT P05T E.N. 2x STUD Pv ava I4 v.v. TO FULL HT. P05T PLAN VIEW 2x LEDGER ..... (E) CONIC WALL -5EE PLAN (E) CONC WALL SCALE : 1 " =I' -O " A54 ANCHOR FOR OPENING GREATER THAN 6-0" AND AT P05T5. (3 PLACES) (2) - 16d FOR 6"' DEEP HEADER. ADD (1) - 16d FOR EA. ADDITIONAL 2" IN DEPTH 16d AT 12" ox.. — PROVIDE E.N. WHERE SHEAR WALL OCCURS'` OTE: OTCH PLYWOOD AROUND POST. BEAM FAR SIDE -5EE PLAN USE (2) - 2x KING 5TUD5 FOR OPNG5. LARGER THAN V -O" DLBE 2x6 HEADER (2) - 2x CRIPPLES WHERE HEADER 15 4x10 (6xS) OR LARGER AND AT HOLDOWN5 2x WINDOW SILL W (2) - 16d T.N. EA. END BEAM -5EE PLAN DOTE: NOTCH PLYWOOD AROUND CORNER POSTS. w i NOTE: PROVIDE 2x BLOCKING BETWEEN STUDS AT 10' -0" ox - MAX. AND AT FIRE BLOCKING AT CEILING LINE. SCALE : N.T.S.