HomeMy WebLinkAboutB20-0420_approved plans_1611352926137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Cover
A0.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1 Approach
2 From the NorthWest
1469 GREENHILL COURT
VAIL COLORADO
LOT 11 GLEN LYON
SUBDIVISION
CONTACTS
VICINITY
TABLE OF CONTENTS
Sheet Number Sheet Name
A0.0 Cover
A1.0 Site
A2.0 ENTRY EAST
A2.1 GUEST EAST
A2.2 LIVING EAST
A2.3 ROOF EAST
A2.4 ENTRY WEST
A2.5 GUEST WEST
A2.6 LIVING WEST
A2.7 ROOF WEST
A3.1 Elevations
A3.2 Elevations
A4.0 Sections
A4.1 Sections
A4.2 Sections
A5.0 Wall Sections
A6.0 Stairs
A6.1 Fire Places
A7.0 Details
A8.0 Schedules
C001 Cover & Notes
C002 Driveway Grading Plan
C003 Excavation Plan
C004 Erosion Control Plan
C005 Construction Details
EL0.1 legend/note/schedule
EL1.0 Lighting Entry East
EL1.1 Lighting Guest East
EL1.2 Lighting Living East
El1.3 Lighting Entry West
EL1.4 Lighting Guest West
EL1.5 Lighting Living West
LA1.1 Landscape
LA5.1 Details & Precedents
S1.0 General Notes
S2.0 Foundation Plan- East
S2.1 Guest Floor Framing - East
S2.2 Living Level Framing - East
S2.3 Roof Level Framing - East
S2.4 Foundation Plan- West
S2.5 Guest Floor Framing - West
S2.6 Living Level Framing - West
S2.7 Roof Level Framing - West
S3.1 Foundation Details
S3.2 Foundation Details
S4.1 Framing Details
S4.2 Framing Details
S5.1 Roof Framing Details
TOV 1.0 GRFA
TOV 1.1 Site Cover/Landscp
TOV 1.2 Hgt 1
TOV 1.3 Hgt 2
TOV 1.4 Slope
LANDSCAPE DESIGN
LANDSCAPE TECHNOLOGY
GROUP
CONTACT Rick Leeman
970 524 0138
INFO@LANDSCAPETECHNOLO
GYGROUP.COM
STRUCTURAL ENGINEER
IMEG
CONTACT Hannes Spaeh
970 390 8910
hannes.p.spaeh@imegcorp.com
CIVIL ENGINEERING
MARCIN ENGINEERING
CONTACT Tim Thompson
970 748 0274
Tim@MarcinEngineering.com
ARCHITECT
RKD ARCHITECTS
CONTACT JACK SNOW
970 926 2622
SNOW@rkdarch.com
GENERAL CONTRACTOR
Sentry Construction
CONTACT Mike Young
970 376 2020
mikeyoung2020@mac.com
ZONING
SUMMARY
ZONING: P/S
LAND USE: LOW DENSITY RESIDENTIAL
LOT SIZE 30.753.46 SF
.706 ACRE
LOW DENSITY RESIDENTIAL ZONING
LOT SIZE 43,560 x .706= 30,753.36 SF
GRFA= 4,600 FIRST 10,000
1,900 10,001 - 15,000X.38
1,950 15,001 -30,000 X .13
753.36 30,001+ X .06
YIELD 8,450 GRFA
SEE SHEETS TOV1.0 &TOV1.1 FOR
ADDITIONAL INFORMATION
GRFA:
TOTAL GRFA 8,450 ALLOWED
Allowed 3,380 40% East
5,070 60% West
Proposed
3,187 East
4,785 West
7,972 TOTAL Proposed
SITE COVERAGE PERMITED:
20% OF LOT= 6,151 MAX
5,623 PROPOSED
LANDSCAPE MINIMUM REQUIREMENT:
60% OF LOT= 18,452 REQUIRED
23,070 PROPOSED
HEIGHT: MAX SLOPED: 33'-0"
MAX PROPOSED: 32'=5 1/4"
SETBACKS: FRONT 20'; REAR AND SIDES 15'
PROPOSED STRUCTURE COMPLIES
PARKING: REQ'D 7-(3) FOR EAST AND (4) FOR WEST
PROPOSED: 8 TOTAL
4 COVERED 4(+) OUTSIDE
PROJECT
INFORMATION
NEW DUPLEX ON AN UNDEVELOPED LOT
OWNER: DEAD DRIFT DEVELOPMENT LLC
1628 14TH ST
APT 4A
DENVER CO 80202
PARCEL # 2103 124 03 021
FIRE DEPT. SUMMARY
SMOKE DETECTORS AND CARBON
MONOXIDE
ALARMS TO BE INSTALLED IN ALL DWELLING
UNITS
PER 2018 IFC AND VFES FIRE ALARM
INSTALLATION
STANDARDS
AN AUTOMATIC FIRE SPRINKLER SYSTEM
AND MONITERED
FIRE ALARM TO BE INSTALLED PER TOWN
OF VAIL
FIRE DEPARTMENT REQUIREMENTS
CODE SUMMARY
P/S
LOT SIZE 30.753.46 SF
.706 ACRE
LOW DENSITY RESIDENTIAL ZONING
JURSIDICTION:
TOV DRB
TOC BUILDING DEPARTMENT
TOV MUNICIPAL CODE INC ADOPTED AMENDMENTS
IRC: 2018
NEC: 2017
IECC: 2018
IPC, IMC, IFGC: 2018
PROJECT
NARRATIVE
PROPOSED STRUCTURE IS A NEW SPECULATIVE
DUPLEX ON A PREVIOUSLY UNDEVELOPED LOT
THE STYLE IS MOUNTAIN MODERN
THE SITE HAS MODERATE DEBRIS FLOW
THE SITE GENERALLY BETWEEN 30% TO 40% SLOPE
Lighting Design
White Lighting
CONTACT Kevin White
303 463 6661
kevin@whitelightingdesign.com
1
Revisions
1 Perm. Resp. 10/5/2020
1
reduced GRFA
Please see Primary side permit for all
Plan Review notes
01/22/21
8122 ' 8124' 8126' 8128'
8130'
8132'
81 34'
8136'
8138'
8 14 0 '
81 4 2 ' 81 4 4' 814 6 ' 8148 ' 8150 ' 8 15 2 ' 81 5 4' 8156' 8 1 2 0 ' 8 1 22' 81 24 ' 81 2 6' 8 1 28' 81 3 0 ' 81 32'
81 34'
8 13 6 ' 8 1 38 ' 81 40'
8142' 8 1 4 4 ' 8146'
8148'
815
0
'
815 2 '
8 1 5 4'
8156'
8158'
8 1 60'
8162'
8 1 64'
8 1 66 ' 8 16 8 ' 8 17 0 '
8172'
8174'
8176'
8178'
8139' - 0 1/2"
8170' - 2"
GREENHILL COURT
4'
pan -
NO
HEA
T
8%
11%
8%
9%
4%
SNOW STORAGE
SNOW STORAGE
SNOW STORAGE
SETBACK
SETBACK
SETBACK
PL
PL
EDGE
OF
ROAD
10
15.4
17
22
23'6
29.2
35
34
28
28
26
24
22
20
30
32
8156' - 1"
59
56
62
64
70
72
78
WATER FEATURE2" / 1'-0"2" / 1'-0"[No Slope]2" / 1'-0"[No Slope] 2" / 1'-0"8170' - 2"
8166' - 5"
8170' - 8 5/8"
8155' - 2 1/8"
8167' - 6"
8173' - 2 7/8"
8173' - 2 7/8"
8173' - 2"
8179' - 6"
8162' - 0"
8172' - 0 3/4"
44
48
CONCRETE DRIVE
HEATED
METERS
1' - 7 3/4"
ROOF AND DECK
1' - 9 3/4"
ROOF ONLY
15' - 0"
15' - 0"15' - 0"1 2 4 3
5 6 8
A
C
D
E
F
B
97
H
I
J
M
N
OP
K
L
Q8177' - 2"
8179' - 6 3/4"
8147' - 4 3/4"
8145' - 0"
Area of heated
drive in ROW
To have
seperate zone -
Mark manifold
box
and coordinate
final location
w/ TOV in field
Manifold Box
VIF- Coord w/
TOV and final
Landscape
Design
(2) 9x18 parking
(note under 2' OH)
(2) 9x19 parking
(note under 6" OH)
SEE A2.0
for
covered
parking
spaces SEE A2.0
for
covered
parking
spacesMATCHLINE
MATCHLINE137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Site
A1.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1" = 10'-0" 1 Site
N
true
Revisions
01/22/21
UP
DN
1
A4.0
Garage
Mech
8128' - 11 5/8"
8129' - 6"
8132' - 6"
8129' - 6"
Coat
ENTRY
Mud/Storage
1 2 43
A
C
D
B
6' - 8" 16' - 0 1/4" 9' - 5 3/4"6"8132' - 0"
8131' - 6" 8129' - 6"
8130' - 6"
8129' - 0" 4' - 0"6' - 4" 4' - 0" 6' - 4" 1
A4.1
(2) 8x19 spaces shown
Mech Chase above -
Drop Clg as needed
5' - 6" 3 1/2" 15' - 9 3/4" 5 1/2" 10' - 10"
guard rail
and grip
provide 2 hr rating
30 min fire
rate w/ sel f
closer
4 1/4" 15' - 0" 5 1/2" 26' - 10 3/4"
3 1/2"5 1/2" 22' - 11 1/4" 5 1/2" 7' - 3 3/4"2%5 1/2"2' - 0"E01
E03
E02
E04
Floor
Sink
vif
Drain vif
3' - 0"1
Entry door system and
sidelites - safety glazed
PASSIVE SLAB DEPRESSURIZATION
FOR RADON MITIGATION: 3" PVC PIPE
EMBEDDED INTO GRAVEL BELOW SLAB
AND EXTENDING 12" ABOVE ROOF LEVEL.
PROVIDE 'T' FITTING AT BASE TO ENSURE
OPENING RESIDES IN GRAVEL LAYER.
(ONE FOR EACH SLAB LEVEL)137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
ENTRY EAST
A2.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Entry - EAST Dependent
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
DN
1
A4.0
Family
OFF/BR #2
Bath #2Laundy
provid
e
floor
drain
Bath #3
CL 2
CL 3
BR #4
CL4
Bath 4
Deck
Bar
Bed #3
UP
Elev
1 2 43
9' - 6" 14' - 0" 24' - 0"
47' - 6"
A
C
D
E
F
B
H
I
5' - 0" 3 1/2" 3' - 0" 3 1/2" 5' - 1 1/2" 3 1/2" 19' - 6 3/4"8' - 8 1/2"5 1/2" 4' - 9" 5 1/2" 11' - 6 1/2" 12' - 2" 5 1/2" 6' - 0" 5 1/2" 12' - 11 1/2" 5 1/2" 12' - 0"5 1/2"
11' - 8 1/2"
3 1/2"2' - 0"
5 1/2"3' - 11" 3 1/2" 8' - 10 3/4"
5' - 7 1/2" 5 1/2" 13' - 5 3/4"
2' - 0"3 1/2" 13' - 8"
1
A4.2
1
A4.1
7' - 10 1/2" 5 1/2" 5' - 4 3/4"7' - 6"4' - 6"6' - 8" 5 1/2"2' - 6 3/4" 8' - 10 1/2" 2' - 6 1/2" 7' - 4 1/2" 9' - 0" 6 1/4"
16' - 2" 14' - 5 1/2" 16' - 10 1/2"
47' - 6" 4' - 10 1/4"5' - 3" 3' - 7 3/4"1' - 4"E201 E202
E208
E209
E207
E204
E203
E205
E206
E210
E211
EA 4' - 10 1/4"3 1/2" 3' - 7" shwr
shwr ben
shwrben
E215
E216
E217
Drop Clg
provide shade
and duct space abv
Direct -Set Window
System - Provide Safety
Glazing at Lower Tier
PASSIVE SLAB DEPRESSURIZATION
FOR RADON MITIGATION: 3" PVC PIPE
EMBEDDED INTO GRAVEL BELOW SLAB
AND EXTENDING 12" ABOVE ROOF LEVEL.
PROVIDE 'T' FITTING AT BASE TO ENSURE
OPENING RESIDES IN GRAVEL LAYER.
(ONE FOR EACH SLAB LEVEL)
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
GUEST EAST
A2.11469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Guest -EAST Dependent
Revisions
01/22/21
1
A4.0
TOV 1.0
3
TOV 1.0 8
A3.2 32' - 7"3 1/2" 6' - 7 1/4"5 1/2" 9' - 3" 5 1/2" 5 1/2" 5' - 11"
3 1/2" 6' - 0 3/4"
5 1/2"1' - 10 3/4" 5' - 0" 6' - 8" 5 1/2" 10' - 4 1/2" 5 1/2" 5' - 7 1/2" 5 1/2" 6' - 2"14' - 5 3/4" 9' - 6"5 1/2"4' - 11 1/2" 5 1/2" 3' - 9 3/4"20' - 5 1/2"20' - 8"Kitchen
M Bth
Dine
Pow
Master
M Closet
Living
Patio
Eating bar
Dining
FP
Elev
DN
1
1
2
2
4
4
3
3
A
C
D
E
F 6' - 8" 16' - 0 1/4" 9' - 5 3/4" 11' - 6" 15' - 2"B 2' - 6" 1' - 6"35' - 0 1/2"5' - 6 1/2"24' - 0"
H
I
TOV 1.3 2
1
A4.2
1
A4.1
10' - 4 1/2" 9' - 9 1/2" 5 1/2"
5 1/2" 5' - 3" 5 1/2" 3' - 7 1/2" 5 1/2" 6' - 2"
Bar
offset vents
from below8' - 7" 3' - 6"3' - 6"4' - 4 1/4"5 1/2" 6" 15' - 0 1/2" 1' - 0"
16' - 7 1/2" 14' - 0" 16' - 10 1/2"
1' - 6" 11' - 9 1/4" 8 3/4" 3' - 9" 11' - 9 1/4" 1' - 4 1/4"3' - 0"1' - 4 1/4" 2' - 1"
2"
2' - 0 1/2" 15' - 9 1/4" 3' - 7 3/4" 2' - 8 3/4"
2' - 6 1/2"3' - 0" 2' - 0 3/4" 5' - 5 1/2" 11' - 9 1/4" 3' - 5 1/4"1' - 1 1/2" 11' - 9 1/4" 1' - 1 1/4" 6' - 0"3' - 0" 3' - 2 1/2"3' - 8"EI
EG
EF
ED
E302
E303
E304
E301
E305
EH
A6.0
1
A6.1 1
A6.1
3
dw dw
triple sink
w/ disposal
cook top
hood
ovens/
micro
ref
frzr
Pre -manufactured
Masonry Fireplace
with gas log insert:
Masonlite MFP 49
ben
1
1
add GRFA
See TOV 1.0
1
remove GRFA
inc landing above
see TOV 1.O
1' - 0"
2' - 11"1 -hour
walls
1 -hour wall
1
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
LIVING EAST
A2.21469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Living - EAST Dependent
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
8167' - 6"2" / 1'-0"2" / 1'-0"2" / 1'-0"Deck
1 2 4 3
A
C
D
E
F
B
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
ROOF EAST
A2.31469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0" 1 ASPEN FALLS Roof - EAST Dependent
Revisions
01/22/21
DN
8135' - 6"
8135' - 0"
Covered Entry
Entry
Garage
CL
Mud
Mech
8138' - 0"
5 6
H
I I
J J
M
4' - 6" 9' - 0" K
L
4' - 6"28' - 0"Q Q
2
A4.0
1
A4.2
1
A4.1
(2) 8x19 spaces shown
chase abv
note
slight
offsets
may be
required
17' - 3 3/4" 5 1/2" 28' - 5 3/4"
17' - 3 3/4" 5 1/2" 15' - 6 1/4" 3 1/2" 12' - 8"23' - 2"5 1/2"3' - 6" 3 1/2"3' - 6"provide 2 hr rating
30 min fire
rate w/ sel f
closer
W01
W02 W03
W04
UP 4 6" RISERS
UP 2 6" RISERS
Floor
Sink
vif Drain vif
7' - 3 1/2"Entry door system and
sidelites - safety glazed
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
ENTRY WEST
A2.41469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Entry - WEST Dependent
Revisions
01/22/21
Family
Laundry
Linen
5 shelves
Pow
Bath 2
Bed 2
CL 2 His
Bed #3
Bath 3
CL 3 Hers
Bed #4
CL 4
Bath 4
Deck
Deck
Elev
UP
DN
Bar
5 6 8
18' - 6" 36' - 0" 7' - 6"
97
H
I
J
M
N
O
P
K
L2' - 0"9' - 0" 8' - 0" 8' - 6" 6' - 0" 13' - 6" Q6"2
A4.0
1
A4.2
1
A4.1
14' - 7 1/4" 4' - 1 3/4" 4' - 0 3/4" 5 1/2" 6' - 0"
6' - 7 1/2" 5 1/2" 3' - 8" 8' - 0" 5 1/2" 3' - 7 1/4" 5 1/2" 5' - 4 3/4"
5 1/2"
12' - 9 1/2"
28' - 7" 5 1/2" 7' - 0" 5 1/2" 6' - 0" 5 1/2" 9' - 2 1/2"14' - 9" 5 1/2"1' - 4 1/4" 6' - 10 1/4"14' - 0" 5 1/2" 8' - 8 1/2" 5 1/2" 8' - 3" 5 1/2"14' - 0" 5 1/2" 7' - 5 3/4" 5 1/2"7' - 6 1/4" 5 1/2" 1' - 6"5 1/2" 4' - 0" 3 1/2" 7' - 11"3 1/2"2' - 6 1/4" 2' - 6"14' - 2"5 1/2"4' - 9 3/4"5 1/2"20' - 2 1/4" 2' - 0"CL 2
2' - 3 1/2" 14' - 7 1/4" 1' - 7 1/4" 3' - 2 1/4" 8' - 10 1/2" 2' - 11 3/4"1' - 10 1/2" 9' - 0" 4' - 3"
18' - 6" 15' - 0 3/4" 15' - 1 1/2" 13' - 3 3/4"
62' - 0"
1' - 0" 11' - 2 1/4" 1' - 1 1/2"4' - 0"6" W201
W205
W204
W214
W208
W207
W206
W209
W210
W212
W211
W213
W202
5
A7.0
WB
WA
WC
shwr ben
provide flr
drain
shwr
shwr ben
W221
W218
W219
Direct -Set Window
System - Provide Safety
Glazing at Lower Tier
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
GUEST WEST
A2.51469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans1/4" = 1'-0"1 ASPEN FALLS Guest - WEST Dependent
Revisions
01/22/21
TOV 1.0
5
TOV 1.06
TOV 1.0
7
TOV 1.0 8
A3.1 3
A3.2 3
Dining
Kitchen
Pantry
Lib
His
CL
Master
Master Bath
FP
Patio
Elev
DN
Living
4
5
5
6
6
8
8
14' - 10" 18' - 6" 19' - 0" 17' - 0" 7' - 6"
54' - 6"
54' - 6"
9
97
H
I
J J
M
N
O
P
2' - 0"9' - 0" 8' - 0" 28' - 0" 4' - 6"9' - 0" K
L13' - 0" 5' - 0"Q Q7' - 0" 8' - 0" TOV 1.3 4
TOV 1.3 2
2
A4.0
1
A4.2
1
A4.1
5 1/2"13' - 10" 5 1/2" 16' - 0 1/2"17' - 4 1/2" 18' - 0 1/2" 16' - 3 1/2"
5 1/2"
3' - 4"
5 1/2"
15' - 0" 5 1/2" 7' - 0 1/2"
5 1/2" 4' - 3" 5 1/2" 11' - 1 1/2" 5 1/2" 5' - 6 1/2" 5 1/2" 3' - 2"
5 1/2"
9' - 2"5 1/2"2' - 9 1/2"5 1/2"5' - 9 1/2" Sealed gas appliance
Town & Country
WS 54
TV
TV 7' - 4 1/2" 5' - 11 3/4" 4' - 0" 2' - 0"2' - 0" 4' - 6" 7' - 6" 9' - 6" 4' - 9 1/2" 12' - 2 1/4" 6' - 4 1/4"2' - 1"
2"
12' - 0" 2' - 8"
2' - 8 3/4" 12' - 0" 2' - 8"
1' - 5" 15' - 9 1/4" 1' - 3 3/4"
1' - 7 1/2"
15' - 9 1/4"
1' - 7 1/4"
3' - 1" 11' - 5 1/4" 2' - 6"
2' - 6 1/2"4' - 0"6" 1' - 8 1/4" 4' - 0" 6 3/4" 2' - 0 3/4" 7' - 7 1/4" 1' - 6" 5' - 6"5' - 0 1/2"5' - 6" 8' - 10 1/2" 2' - 11 1/4" 3' - 0" 2' - 1" 3' - 0" 5' - 7 3/4" 4' - 0" 6" 3' - 0" 4' - 0" 6"
18' - 6" 36' - 0" 7' - 6"
5
A7.0
WE
WG
WH
WI
WF
W301
W303 W304
W305
W307 W308
W309
W306
A6.1
3
ben
cook top
hood
ovens/
micro
ref
frzr
dw dw
triple sink
w/ disposal
pow
Deck
W302
high high
Pre-manufactured
Masonry Fireplace with
gas log insert:
Masonlite MFP 49
1
1
add GRFA
See TOV 1.0
1
remove GRFA
inc landing
above
see TOV 1.O
1' - 0"
2' - 11"
1 -hour wall
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
LIVING WEST
A2.61469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Living - WEST Dependent
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
[No Slope]2" / 1'-0"2" / 1'-0"Deck
4
5 6 8 97
H
I
J
M
N
O
P
K
L
Q
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
ROOF WEST
A2.71469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 ASPEN FALLS Roof - WEST Dependent
Revisions
01/22/21
AF Entry W
8138' - 0"
AF Guest W
8150' - 0"
AF Living W
8162' - 0"
EAST AF Entry
8132' - 6"
EAST AF Guest
8144' - 6"
EAST AF Living
8156' - 6"
Stone
Standing Seam Metal Roof
Fascia to match roof
Blackened metal facia on decks and
flat roofs
Wood Siding
wood and metal rail
tube steel column
MAX HEIGHT
1 2
4 3 5 6 8 97
1A
1B
E04
EA
EFED
W04
WA 8A 8B WC
20E 20F 20G
20A 20B 20C 20D
WF
11 12
13A
13B 13C 15B 15C
15A
Chimney Cap
1
1
Direct -Set Clad
Window System -
Safety Glazing at
Lower Tier
Direct -Set Clad
Window System -
Safety Glazing at
Lower Tier
1
1 2' - 0"EAST AF Entry
8132' - 6"
EAST AF Guest
8144' - 6"
EAST AF Living
8156' - 6"most restrictive point from proposed grade31' - 2"2" / 1'-0"
2" / 1'-0"
EXISTING GRADE25' - 5"EH
7
Direct -Set Window
System - Provide Safety
Glazing at Lower Tier
1
AF Entry W
8138' - 0"
AF Guest W
8150' - 0"
AF Living W
8162' - 0"
EAST AF Entry
8132' - 6"
HI J M N O P Q
existing grade 32' - 2"A5.0
2
WB
Storefront
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Elevations
A3.11469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/8" = 1'-0"1 AF North
1/8" = 1'-0"2 AF East
1/8" = 1'-0"3 AF West Unit from Falls
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
AF Entry W
8138' - 0"
AF Guest W
8150' - 0"
AF Living W
8162' - 0"
TRELLIS
9A 9B 9C
10B 10C
10A
14B14C 16B 16C
16A14A WE
AF Living W
8162' - 0"
EAST AF Living
8156' - 6"
12
4
35 6 8 9 7 2
A4.0
EG
6B 6C
EI
6A
17A 17B 17C 18A 18B
WG WH
WI
19E 19F 19G
19A 19B 19C 19D
18C
2' - 0"AF Entry W
8138' - 0"
EAST AF Entry
8132' - 6"
EAST AF Guest
8144' - 6"
EAST AF Living
8156' - 6"
A C D E FB
existing grade
2A 2B 3A 3B 3C 4A 4B
5
6
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Elevations
A3.21469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/8" = 1'-0"1 AF West
1/8" = 1'-0"2 AF South
1/8" = 1'-0"3 AF East Unit from Falls
SEE 1/A3.1 FOR MATERIALS
DINING
WEST UNIT
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
AF Living W
8162' - 0"
AF Roof Terrace W
8172' - 0"
EAST AF Living
8156' - 6"
EAST AF Roof
Terrace
8167' - 6"
A C D E F B
14' - 1 3/4"Garage Mech
Family Bedroom Bedroom
Bedroom Living RoomKitchen
1
A4.2
1
A4.1
A7.0
6
A7.0
4
A5.0
1
Slab per Structural on 3" Rigid
Insulation (R-15) on 4" Gravel per
soils report
2" Rigid Insulation (R-10) to
48" below grade, typ. (3/4"
protection board below 48")
Drainage Fabric and
foundation drain per Soils
report at each level of
backfill.
1
Ceiling Finish with NO vapor barrier
3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
1
AF Entry W
8138' - 0"
AF Guest W
8150' - 0"
AF Living W
8162' - 0"
AF Roof Terrace W
8172' - 0"
AF Roof W
8184' - 0"
EAST AF Guest
8144' - 6"
EAST AF Living
8156' - 6"
EAST AF Roof
Terrace
8167' - 6"
EAST AF Roof
8178' - 6"
H I J M N O PQ 12' - 9"15' - 10 3/4"Garage
BR
Great Room
Dining Beyond
BR
Mud
1
A4.2
1
A4.1
Drop Clg to flush out
Typical exterior wall system
- 5/8" type X drywall
NO vapor barrier
- 2x6 framing
- 1" Closed Cell Spray Foam Insul.
- Fill remaining cavity with Batt
or BIBS insulation to achieve
R-20 in cavity .
- 1/2" sheating (re struct)
- 1 1/2" polyisocyanurate
insulation to achieve R-5 min.
contin .
- Exterior Finish (Siding or
Metal)
on Obdyke (or equal) rain screen
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Sections
A4.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 East Unit 1
1/4" = 1'-0"2 West Unit 1
Revisions
1 Perm. Resp. 10/5/2020
1
01/22/21
1
A4.0
1 2
4 3 5 6 8 97 2
A4.0 6' - 0"Garage
Mud
Bath
BR
Stair
Elev
Kitchen
EAST
WEST
Square footage in this region
is factored See TOV 1.0 GRFA
5
A7.0
Mech
Stair
BR
Master BathLiving
beyond
Kitch bey
Slab per Structural on 3" Rigid
Insulation (R-15) on 4" Gravel per
soils report
Drainage Fabric and
foundation drain per Soils
report at each level of
backfill.
Ceiling Finish with NO vapor barrier
3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Sections
A4.11469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 Longitudinal Section 1
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
1
A4.0
12
4 35 6 8 9 2
A4.0
Cl Master
Living
Kitchen
Dine
BR Family
Living
EASTWEST
A7.0
3
Cl
mech chase
A5.0
3
1
Slab per Structural on 3" Rigid
Insulation (R-15) on 4" Gravel per
soils report
2" Rigid Insulation (R-10) to
48" below grade, typ. (3/4"
protection board below 48")
Drainage Fabric and
foundation drain per Soils
report at each level of
backfill.
Ceiling Finish with NO vapor barrier
3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
1
1 -hour party wall
continuous to top of
parapet
11
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Sections
A4.21469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/4" = 1'-0"1 Longitudinal Section 2
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
AF Living W
8162' - 0"
EAST AF Living
8156' - 6"
A7.0
2
Typical Exterior wall
See 2/A5.0
provide Steel frame
per structural
Slope away at 1/4:"/ft
provide cut stone kick/riser
5"stone patio on conc slab
Typical Sloped Roof System
- 5/8" type X drywall NO vapor barrier
- Roof framing re struct
- 3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
- Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
- Framing and sheating (re struct)
- Roofing to be Standing Seam metal Roof
on full waterproofing membrane.
Slab per Structural on 3" Rigid
Insulation (R-15) on 4" Gravel per
soils report
2" Rigid Insulation (R-10) to
48" below grade, typ. (3/4"
protection board below 48")
1
1
Drainage Fabric and
foundation drain per Soils
report
Fluid-applied 180 -mil
waterproofing membrane
AF Living W
8162' - 0"
A7.0
1
Typical exterior wall system
- 5/8" type X drywall
NO vapor barrier
- 2x6 framing
- 1" Closed Cell Spray Foam Insul.
- Fill remaining cavity with Batt
or BIBS insulation to achieve
R-20 in cavity .
- 1/2" sheating (re struct)
- 1 1/2" polyisocyanurate
insulation to achieve R-5 min.
contin .
- Exterior Finish (Siding or
Metal)
on Obdyke (or equal) rain screen
Typical Floor system
- 1 1/2" total Fin Floor system
- 1 1/2" Gypdrete w/ In floor
heat
- 3/4" Ply
- Structure --varies re struct
- BIBs or Batt Insulation to
achieve R-30 min.1 1/2"1 1/2"3/4" 1' - 0" Typical Flat Roof System
- 5/8" type X drywall NO vapor barrier
- Roof framing re struct
- 3" Closed Cell Spray Foam Insul.
Installed against sheathing
- Fill remaining cavity with Batt or BIBS
insulation to achieve R-50 min .
- (14" structure)
- sheating (re struct)
- Tapered rigid insulation slope to drain
(provide overflow scuppers
- Roofing to be single ply 60 mil epdm
roof membrane
provide cant strips and counter flashing
flash all parapets
1
20F
20C
1
1
AF Living W
8162' - 0"
EAST AF Living
8156' - 6"
Typical Flat Roof -
See 2/A5.0
Typical Sloped Roof -
See 1/A5.0
3 1/2"
5 1/2"
1"
5 1/2"
1
3-1/2" sound wall w/
full insulation
2x6 structural wall
2x6 wall with 5/8"
type 'x' gyp. bd. ea.
side. Continuous up
to parapet. Firetaped.
Parapet Flashing
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Wall Sections
A5.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1" = 1'-0"1 Wall Section
1" = 1'-0"2 Wall Section 2
Revisions
1 Perm. Resp. 10/5/2020
1" = 1'-0"3 Section at Common Wall
01/22/21
1 2
C
B
2
A6.0
3
A6.0
ts 6x6
col
pnuem.
tube
elevator
TYP.
1' - 0"
TYP. NOSING
1"
1
EAST AF Entry
8132' - 6"
EAST AF Guest
8144' - 6"
EAST AF Living
8156' - 6"
1 2
3
A6.0
21 R. @ 6-7/8" =12' - 0"21 R. @ 6-7/8" =12' - 0"1' - 0"
4' - 2 3/4"
6 TR. @ 12" =
6' - 0"
1
AF Guest W
8150' - 0"
C B H
2
A6.0
RAILING SEE 6/a7.0 SIM
(PROVIDE GRIPABLE HAND RAIL)
2 1/2" 4' - 2"
6 TR. @ 12" =
6' - 0" 4' - 2" 1 3/4"
TYP. NOSING
1"3" - 3-1/4"MAX GAP3 3/4"1
1
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Stairs
A6.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/2" = 1'-0"1 ASPEN FALLS Stair
1/2" = 1'-0" 2 Stair 1
1/2" = 1'-0"3 Stair 2
NOTE
WEST UNIT SHOWN
EAST UNIT SIM
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
AF Living W
8162' - 0"
EAST AF Living
8156' - 6"
EAST AF Roof
Terrace
8167' - 6"
2
A6.1
2' - 2 1/4"5 1/2"6" 10 3/4" Masonlite FP 49
EAST AF Living
8156' - 6"
2' - 6 1/2"
2'6" provides 2"
clearance per Mason -lite
specs
Non - Comb construction
18" abv box
MIN
3' - 0"A6.1 1
2
A6.1
1' - 7 3/4"
2' - 6"
1' - 0"6' - 0"2' - 6 1/2"
Maintain 2" Air space
all sides
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Fire Places
A6.11469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1/2" = 1'-0"1 FP Living Room
1/2" = 1'-0"2 FP Section 1
1/2" = 1'-0" 3 FIRE PLACE Living
Revisions
01/22/21
AF Living W
8162' - 0"
AF Roof Terrace W
8172' - 0"
F
9
C15x
1"HSS 4x5
Flashing
EPDM Roofing on tapered
insulation. Wrap membrane
over parapet edge
T&G Soffit on 5/8" Type 'x'
gyp. bd. fireproofing - firetape
5/8" type X drywall NO vapor barrier on
Roof framing re struct w/
3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
1
A
T&G Soffit on 5/8" Type 'x'
gyp. bd. fireproofing - firetape
RS 2x8
2x blocking
Flashing to match roof
9"
9"
1/4"
Full bithithane waterproofing
standing seam roof 1"5/8" type X drywall NO vapor barrier on
Roof framing re struct w/
3" Closed Cell Spray Foam Insul. Installed
against sheathing R-26 min.
Fill remaining cavity with Batt or BIBS
insulation to achieve a total of R-50 min .
AF Guest W
8150' - 0"
IJ
Q
3x12 exposed timber
Framing - re: Struct.
Exposed steel beam - re:
Struct.
Ballast on EPDM membrane roofing on
tapered insulation to drain
Exposed steel channel fascia
ENTRY
full closed cell spray foam, impermeable
insulation applied directly to roof
sheathing. R-50 min.
1' - 0"
C channel 7x4
15" HSS
HSS 4x2
1"x1" bar
HSS 4x2
HSS 4x2
2x6 wood top rail
ease edge
1 1/2"4" 3 1/2" 1" 4" 1" 4" 1" 4" 1" 4" 4" 3" 3' - 0"137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Details
A7.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
1 1/2" = 1'-0" 1 Sill
1 1/2" = 1'-0"2 Head
1 1/2" = 1'-0"3 Fascia Flat Roof
1 1/2" = 1'-0"4 Fascia
3/4" = 1'-0"5 Entry Roof
1 1/2" = 1'-0"6 Deck /Railing
Revisions
1 Perm. Resp. 10/5/2020
01/22/21
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 19020
10/10/2020
Schedules
A8.01469 Greenhill CourtVail CO 81658Lot 11 Glen Lyon SubdivisionAmend Approved
Plans
Revisions
1 Perm. Resp. 10/5/2020
2 Revision 2 11/3/2020
1
3. Direct -Set Clad Window Systems at both stairways are to be field -measured and shop drawings are
to be provided prior to manufacturing. Note that the Guest Level panels, as well as the lower tier
of the Living Level panels are to contain safety glazing.
.30
2
01/22/21
Thomas
A. Printz
Digitally signed by Thomas A. Printz
DN: cn=Thomas A. Printz
gn=Thomas A. Printz c=US United
States l=US United States o=Printz
Engineering Services, LLC
e=tprintz@printzengineeringservices
.com
Reason: I am the author of this
document
Location:
Date: 2020-12-04 12:13-07:00
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. ROOF PITCH 4:12 OR STEEPER 80 PSF
B. ROOF PITCH LESS THAN 4:12 100 PSF
C. TYPICAL FLOOR 40 PSF
D. EXTERIOR DECK 100 PSF
E. RISK CATEGORY II
SEISMIC FACTOR IE 1.0
SNOW FACTOR IS 1.0
F. WIND
WIND SPEED, Vult 115 MPH (ULTIMATE)
WIND SPEED, Vasd 89 MPH (ASD)
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT (GCpi) +/- 0.18
G. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
H. CODE USED IN DESIGN: INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION.
2. DEFERRED SUBMITTAL
A. DEFERRED SUBMITTALS PER SECTION 107.3.4.1 SHALL BE SUBMITTED TO THE BUILDING
OFFICIAL AND THE DESIGN PROFESSIONALS AND REVIEWED PRIOR TO INSTALLATION.
B. DEFERRED SUBMITTALS ARE:
1. STRUCTURAL STEEL SHOP DRAWINGS.
C. ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE
LICENSED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE PREPARATION OF THESE
DOCUMENTS.
3. TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. SOIL PREPARATION
a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL
AND IN-PLACE DRY DENSITY OF THE COMPACTED FILL FOR
CONFORMANCE WITH THE APPROVED REPORT.
2. CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL AND PLACEMENT.
b. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
c. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
d. CONTINUOUS INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
e. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
3. STEEL CONSTRUCTION - COMPLY WITH AISC 360, CHAPTER N.
a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION
EXCEPT THE FOLLOWING:
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
ACCORDANCE WITH AISC 360, CHAPTER N.
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE
MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
WELDING.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.
2. WELDING OF STAIRS AND RAILING SYSTEMS.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. PERIODIC INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE
WITH THE DETAILS SHOWN ON THE APPROVED CONSTRUCTION
DOCUMENTS SUCH AS BRACING, STIFFENING, MEMBER LOCATIONS AND
PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION.
e. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
f. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS
FOR CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OF
COMPLIANCE.
g. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGH
STRENGTH BOLTS.
1. WHILE THE WORK IS IN PROGRESS, THE SPECIAL INSPECTOR
SHALL DETERMINE THAT THE REQUIREMENTS FOR BOLTS, NUTS,
WASHERS AND PAINT, BOLTED PARTS AND INSTALLATION AND
TIGHTENING IN SUCH STANDARDS ARE MET. FOR BOLTS
REQUIRING PRETENSIONING, THE SPECIAL INSPECTOR SHALL
OBSERVE THE PREINSTALLATION TESTING AND CALIBRATION
PROCEDURES WHEN SUCH PROCEDURES ARE REQUIRED BY THE
INSTALLATION METHOD OR BY PROJECT PLANS OR
SPECIFICATIONS; DETERMINE THAT ALL PLIES OF CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED AND MONITOR THE INSTALLATION OF BOLTS TO VERIFY
THAT THE SELECTED PROCEDURE FOR INSTALLATION IS
PROPERLY USED TO TIGHTEN BOLTS. FOR JOINTS REQUIRED TO
BE TIGHTENED ONLY TO THE SNUG-TIGHT CONDITION, THE
SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED.
2. MONITORING OF BOLT INSTALLATION FOR PRETENSIONING IS
PERMITTED TO BE PERFORMED ON A PERIODIC BASIS WHEN
USING THE TURN-OF-NUT METHOD WITH MATCHMARKING
TECHNIQUES, THE DIRECT TENSION INDICATOR METHOD OR THE
ALTERNATE DESIGN FASTENER (TWIST-OFF BOLT) METHOD.
JOINTS DESIGNATED AS SNUG TIGHT NEED TO BE INSPECTED
ONLY ON A PERIODIC BASIS.
4. FOUNDATIONS
A. MAXIMUM SOIL DESIGN PRESSURE 2000 PSF
B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT NO. 19-7-170
BY KUMAR & ASSOCIATES DATED JULY 12, 2019.
C. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING
ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY
CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS
SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.
D. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR
PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL
SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ASTM
D1557 UNLESS OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS ARE
ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOIL
REPORT FOR DESCRIPTION OF BEARING SOIL).
E. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12
INCH MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFER
TO SOILS REPORT FOR BACKFILL MATERIAL.
F. NO BACKFILLING SHALL BE PLACED AGAINST LOWER LEVEL WALLS UNTIL THE LOWER
LEVEL FLOOR AND MAIN LEVEL FLOOR ARE IN PLACE AND PROPERLY ANCHORED.
CONCRETE SLABS SHALL BE PROPERLY CURED.
G. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES UNLESS NOTED
OTHERWISE ON PLANS.
H. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTED
FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE.
I. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY
BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
J. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS.
5. CONCRETE
A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
FOOTINGS 3000 psi STD --- ---
FOUNDATION WALLS (RESIDENTIAL) 3000 psi STD --- ---
ARCHITECTURALLY EXPOSED
EXTERIOR CONCRETE WALLS 4500 psi STD 0.45 6%-8%
GRADE BEAMS (*) 4000 psi STD --- ---
INTERIOR SLABS ON GRADE (RESIDENTIAL) 4000 psi STD 0.50 ---
EXTERIOR CONCRETE (++) 4500 psi STD 0.45 6%-8%
+FOR ALL CONCRETE SUBJECT TO SULFATE ATTACK OR POSSIBLE CONTACT WITH ROAD
SALTS W/C RATIO SHALL NOT EXCEED 0.4.
++MAXIMUM SLUMP SHALL NOT EXCEED 4".
B. THE MODULUS OF ELASTICITY OF ALL CONCRETE SHALL EXCEED WC1.5 33 ?F'C (OR
57,000 ?F'C NORMAL WEIGHT CONCRETE). GENERAL CONTRACTOR TO PROVIDE THE
ENGINEER OF RECORD WITH MODULUS OF ELASTICITY TEST RESULT.
C. CALCIUM CHLORIDE SHALL NOT BE USED. FLYASH (CLASS C) SHALL NOT BE USED.
POZZOLANS SHALL NOT BE USED WITHOUT PRIOR APPROVAL BY ENGINEER OF
RECORD. IF APPROVED, POZZOLANS SHALL BE LIMITED TO (25) % OF CEMENT CONTENT
BY WEIGHT IN ALL STRUCTURAL ELEMENTS. IF CONCRETE SUPPLIER PROPOSES USE OF
POZZOLANS HE SHALL PROVIDE OWNER WITH LETTER INDICATING COST REDUCTION AT
TIME OF BID.
D. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTS
SHALL BE SPACED AT 12 FEET MAXIMUM AND NOT EXCEEDING 144 SQUARE FEET.
SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16" WIDE WITHIN 12 HOURS AFTER
POURING. CARRY ALL SLAB REINFORCEMENT THROUGH JOINT. CONTRACTOR TO
COORDINATE EXACT JOINT LAYOUT WITH ARCHITECT OF RECORD.
E. SLABS, TOPPING, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF
SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE
SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE
ENGINEER.
F. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
6. REINFORCEMENT
A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE
LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER.
C. REINFORCEMENT CLEAR COVER PROTECTION MILDLY REINFORCED UNLESS NOTED
OTHERWISE:
1. CONCRETE POURED AGAINST EARTH 3"
2. CONCRETE POURED ON VOID FORM 2"
3. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH)
BARS #5 AND SMALLER 1-1/2"
BARS LARGER THAN #5 2"
4. COLUMNS AND BEAMS (TIE BARS) 1-1/2"
5. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4"
D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
OF ACI 318, LATEST EDITION.
E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL
BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE A
MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTED
OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN
CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT
EACH CORNER.
G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS
FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS.
H. PLACE (3)-#5 VERTICALLY FULL HEIGHT OF CONCRETE WALLS AT HIGH SIDE OF ALL
WALL STEPS GREATER THAN 4'-0", IN ADDITIONAL TO WALL REINFORCING SHOWN ON
PLANS.
7. POST-INSTALLED ANCHORAGES
A. ALL POST-INSTALLED ANCHORS AND BOLTS SHALL MEET ICC-ES COMPLIANCE FOR
EACH TYPE OF APPLICATION.
B. ALL CONCRETE MUST BE A MINIMUM OF 14 DAYS OLD AND ACHIEVED 100% OF f'c PRIOR
TO INSTALLATION OF ANCHORS.
C. GENERAL CONTRACTOR TO SUBMIT ALL POST-INSTALLED PRODUCT DATA FOR REVIEW.
D. POST-INSTALLED ANCHORAGES SHALL BE INSTALLED ACCORDING TO THE
MANUFACTURES REQUIREMENTS, INCLUDING THE PREPARATION AND CLEANING OUT
OF DRILLED HOLES.
E. THE FOLLOWING ARE THE ACCEPTABLE POST-INSTALLED ANCHORAGES AS
MANUFACTURED BY SIMPSON STRONG-TIE.
1. ADHESIVE ANCHORS IN CONCRETE SHALL BE SET-XP OR AT-XP
2. ADHESIVE ANCHORS IN SOLID GROUTED CMU SHALL BE SET-XP OR ET-HP
3. ADHESIVE ANCHORS IN HOLLOW CMU SHALL BE SET-XP
4. MECHANICAL ANCHORS IN CONCRETE SHALL BE STRONG-BOLT 2 OR TITEN HD
5. MECHANICAL ANCHORS IN CONCRETE ON METAL DECK SHALL BE STRONG-BOLT
2 OR TITEN HD
6. MECHANICAL ANCHORS IN SOLID GROUTED CMU SHALL BE STRONG-BOLT 2 OR
TITEN HD
7. MECHANICAL ANCHORS IN HOLLOW CMU SHALL BE TITEN OR TITEN HD.
F. ALTERNATES MUST BE REVIEWED BY THE ENGINEER OF RECORD PRIOR TO
INSTALLATION. GENERAL CONTRACTOR TO SUBMIT PRODUCT AND TESTING DATA,
INCLUDING MANUFACTURER'S INFORMATION AS WELL AS ICC EVALUATION SERVICES
REPORT.
8. STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS
WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH
SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATEST
EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
MISCELLANEOUS STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 UNLESS
NOTED OTHERWISE. MISCELLANEOUS EMBEDDED STEEL ITEMS SHALL BE A36 STEEL
UNLESS NOTED OTHERWISE.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GR. 36 UNLESS
NOTED OTHERWISE.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL
CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A
AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED
EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN
LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM
LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM
AND SPAN FOR NON-COMPOSITE MEMBERS.
SUBMIT DESIGN CALCULATIONS, BEARING THE STAMP AND SIGNATURE OF THE
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO, AND EMPLOYED BY
THE STEEL FABRICATOR, FOR ALL CONNECTIONS NOT COMPLETELY DETAILED ON THE
STRUCTURAL DRAWINGS AND FOR ANY PROPOSED ALTERNATE CONNECTION DETAILS.
E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1.
F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT
SLOTS IN CONNECTION MEMBER ONLY (WT-SECTIONS, ANGLES OR SHEAR PLATES).
H. STRUCTURAL STEEL SUPPLIER TO FURNISH LINTELS FOR ALL MASONRY OPENINGS PER
LOOSE LINTEL SCHEDULE OR AS SHOWN OTHERWISE ON STRUCTURAL DRAWINGS. ONE
END OF THE LINTEL SHALL BE FREE TO MOVE HORIZONTALLY TO ALLOW FOR
ELONGATION AND SHORTENING.
I. THE TERMINOLOGY "CONTINUOUS" MEANS QUANTITY. PROVIDE THE NECESSARY JOINT
DETAILS TO ALLOW FOR BUILDING MOVEMENTS. COORDINATE LOCATIONS WITH
ARCHITECTURAL CONTROL AND EXPANSION JOINTS.
J. PROVIDE ANCHOR BOLTS FOR BEAMS BEARING ON CONCRETE UNLESS OTHERWISE
NOTED.
K. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALL
STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR
LATERAL LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT
LATERAL SYSTEMS AND DECKS ARE IN PLACE.
L. STEEL FABRICATOR SHALL NOT RECEIVE ADDITIONAL COMPENSATION FOR SHOP
DRAWING TIME FOR ANY REVISIONS TO ERECTION DRAWINGS NOR FOR ANY REVISIONS
TO PIECE DRAWINGS PRIOR TO ENGINEER'S APPROVAL OF ERECTION DRAWINGS.
M. UNLESS NOTED OTHERWISE, WHENEVER MASONRY RESTS ON STEEL BEAMS WITH
FLANGES NARROWER THAN ACTUAL MASONRY THICKNESS, WELD 1/4" THICK
CONTINUOUS PLATE TO BEAM FLANGE. WIDTH OF PLATE TO BE 1/2" NARROWER THAN
MASONRY THICKNESS.
9. NON-SHRINK GROUT
A. NON-SHRINK GROUT SHALL BE PROVIDED:
1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS.
2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY
SUPPORTS.
3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.
10. WOOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSI
5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITIVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. ALL LUMBER IN CONTACT WITH CONCRETE, MASONRY, WITHIN 8 INCHES FROM
EXPOSED EARTH OR EXPOSED TO EXTERIOR ELEMENTS SHALL BE PRESERVATIVE
TREATED LUMBER IN ACCORDANCE WITH AWPA U1 WITH A SERVICE CONDITION AS
REQUIRED FOR USE OR NATURALLY DURABLE WOOD PER IBC2304.
C. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS.
SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS
IS REQUIRED.
E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304.10.1 UNLESS NOTED OTHERWISE.
F. NOTCHES AND BORED HOLE PENETRATIONS IN WOOD STUD WALLS SHALL CONFORM
TO SECTION 2308 OF THE INTERNATIONAL BUILDING CODE.
G. LAMINATED BEAMS
1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT
LESS THAN 12 PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL
SIZES SHOWN ARE NET.
2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF
STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC.
3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS
MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.
MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE
CLEARLY STAMPED ON EACH MEMBER. (IF LAMINATED COLUMNS ARE USED,
SPECIFY ACCORDINGLY, GRADE "DF L2)
H. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
4. FOR ROOF USE 5/8" (40/20 SPAN RATING) EXPOSURE I SHEATHING NAILED
WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d (OR 10d) NAILS AT 6" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
I. WOOD DECK
WOOD DECKING SHALL BE 2x T&G DOUGLAS-FIR LARCH (E=1,700,000 PSI, Fb=1450 PSI).
PLANKS SHALL BE SPLICED AT CENTER OF SUPPORT MEMBERS WITH ADJACENT
PLANKS SPLICED AT ALTERNATE SUPPORT MEMBERS. EACH DECK PLANK SHALL BE
SLANT-NAILED TO THE TONGUE OF THE ADJOINING COURSE WITH 8d NAILS AT 24" ON
CENTER WITH ALTERNATE PLANK NAILING OFFSET 12". NAIL EACH PLANK TO EACH
SUPPORT WITH (2)-16d NAILS-1 STRAIGHT, 1 SLANTED. WOOD DECKING SHALL BE GLUED
IN THE GROOVE JOINT WITH 40% GLUE COVERAGE.
J. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND
SHALL BE "BCI-JOIST" AS MANUFACTURED BY BOISE CASCADE. ALTERNATES SHALL BE
REVIEWED BY THE ENGINEER. TO BE CONSIDERED, ALTERNATES SHALL HAVE A LOAD
CAPACITY IN BENDING, SHEAR AND DEFLECTION EQUAL TO OR GREATER THAN THE
SIZE SHOWN ON THE DRAWINGS. WEB BLOCKING AND BRIDGING TO BE AS REQUIRED
BY THE JOIST MANUFACTURER.
K. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS
CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UP
MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR
5 1/4" WIDE MEMBERS.
L. ALL SOLID SAWN, LAMINATED VENEER LUMBER, AND PREFABRICATED WOOD MEMBER
HANGERS ARE TO BE INSTALLED USING THE MAXIMUM NUMBER OF FASTENERS AS
SPECIFIED BY THE HANGER MANUFACTURER, UNLESS NOTED OTHERWISE.
M. ALL WOOD HANGERS ARE TO BE THE TYPE NOTED ON THE DRAWINGS AND SHALL BE
MANUFACTURED BY SIMPSON STRONG-TIE. ALTERNATES SHALL HAVE EQUAL OR
GREATER CAPACITY.
11. NON-STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
12. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND
ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND
REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.
C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER
ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS
AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON
ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR
SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF
HIS ITEMS.
D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED
ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED
BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36.
E. PROVIDE ASPHALTIC MASTIC-COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.
F. SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL
STRUCTURAL STEEL. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO
WRITTEN REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE
CONTRACTOR. SHOP DRAWINGS NOT REVIEWED AND STAMPED BY CONTRACTOR
PRIOR TO SUBMITTING WILL BE RETURNED AND NOT REVIEWED.
G. WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
H. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR
WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.
I. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS AND ARCHITECTURAL DRAWINGS.
J. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER. (FOR RENOVATIONS OR
ADDITIONS)
K. PRE-MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL
HAVE ALL ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND
SHALL BE SUBMITTED FOR ARCHITECTS REVIEW BEARING THE SEAL OF A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. STAIRS SHALL
BE DESIGNED TO SUPPORT A LIVE LOAD OF 100 PSF. SEE ARCHITECTURAL DRAWINGS
FOR ADDITIONAL REQUIREMENTS AND CRITERIA.
L. ALL HOUSEKEEPING PAD LOCATIONS AND EXTENTS SHALL BE COORDINATED WITH
ARCHITECTURAL AND MECHANICAL DRAWINGS.6'-0" MAXIMUM3'-0" MINIMUM 1'-0" MIN.
SECTION 1
3/4" = 1'-0"
NOTES:
1. FILL BEHIND BOULDERS SHALL BE SELF COMPACTING, FREE-DRAINING GRAVEL.
2, ALL BOULDERS SHALL BE RECTANGULAR SHAPED, WITH FLAT CONTACT SURFACES.
3. BOULDER JOINTS SHALL BE OFFSET ALONG LENGTH OF WALL.
4. CONTACT SURFACES BETWEEN BOULDERS SHALL BE GROUTED OR HAVE SANDBED.
GRADE
BOULDER WALL
PERMANENT SHORING
WALL
SHEAR WALL SCHEDULE
MATERIAL ATTACHMENTS AND VALUE PER THE 2018 IBC
PLAN MARK ANCHOR BOLTS AT
FOUNDATION OR
STRUCTURAL SLAB
BLOCKING / RIM
ATTACHMENT TO WALL
PLATES
SW1
XX
WALL SHEATHING
AND ATTACHMENT
7/16" OSB SHEATHING WITH
8d COMMONS 6" O.C.
EDGES, 12" O.C. FIELD
FRAMING MEMBERS
AT ABUTTING
PANEL EDGES
2X
SILL PLATE CONNECTION TO
BLOCKING / RIM AT FRAMED FLOORS
(USE SHEAR WALL MARK BELOW FLOOR)
16d COMMON NAILS AT 5" O.C. INTO
SOLID BLOCKING OR SDS 1/4" X 4 1/2"
WOOD SCREWS AT 9" OR SIMPSON A35
AT 1'-9" MAX.
1/2"Ø X 10" A.B. OR
5/8" X 6 1/2" TITEN HD
AT 2'-6" O.C.
SIMPSON A35 OR
LTP4 AT 1'-9" MAX.
HOLDOWN SCHEDULE
SIMPSON HOLDOWN
FLOOR TO FLOOR ALTERNATE HOLDOWNSIMPSON HOLDOWN
AT CONCRETEMARK
A HDU2.5-SDS2.5
ANCHOR BOLT
5/8"Ø EPOXY
ANCHOR WITH 5"
EMBED INTO
CONCRETE
BOUNDARY COLUMN
(2)-2X6
(2)-HDU2-SDS2.5 WITH
5/8"Ø THREADED ROD
THRU FLOOR
ASSEMBLY
MSTC40
(36)-19d COMMON
B (2)-2X6
(2)-HDU2-SDS2.5 WITH
5/8"Ø THREADED ROD
THRU FLOOR
ASSEMBLY
HDU5-SDS2.5
NOTES:
1. ALL PLYWOOD PANEL EDGES SHALL BE BLOCKED. BLOCKING SHALL MATCH THE STUDS AT ADJOINING PANEL EDGES.
2. NAIL SPACING AT 12" O.C. ALONG INTERMEDIATE FRAMING MEMBERS.
3. STAGGER ALL SHEATHING JOINT AND SILL PLATE NAILING.
4. NAILS SHALL BE COMMON OR GALVANIZED BOX IN PLYWOOD SHEAR WALLS.
5. ALL PLYWOOD PANELS SHALL BE APA RATED EXPOSURE 1 SHEATHING, UNLESS NOTED OTHERWISE.
6. EXTENT OF SHEAR WALL INDICATED BY ON PLAN.
7. ALL EXTERIOR WALLS SHALL BE TYPE U.N.O.
NOTES:
1. SIMPSON HOLDOWNS SHALL BE AS NOTED ON PLAN AND INSTALLED PER MANUFACTURER.
2. SIMPSON FLOOR TO FLOOR HOLDOWN STRAPS SHALL BE AS NOTED ON PLANS. HOLDOWNS ARE CALLED OUT AT THE BOTTOM
OF THE SHEAR WALL ON PLAN, AND SHALL BE INSTALLED AT EACH END OF THE WALL.
3. MINIMUM HOLDOWN COLUMN AT EACH END SHALL BE (2)-2X6 FASTENED TOGETHER WITH NAILING EQUIVALENT TO THE PANEL EDGE NAILING.
4. ANCHOR BOLTS SHALL BE INSTALLED WITH A HEAVY HEX NUT, TIGHTEN PER HOLDOWN MANUFACTURER RECOMMENDATION,
SNUG TIGHT AND TURN 1/3 TURN (MINIMUM).
5. SEE DETAIL 7/S4.2 FOR HOLDOWN ANCHOR BOLT CONNECTION TO STEEL.
SW1
S#X
INDICATES HOLDOWN
TYPE AT EACH END OF WALL
INDICATES
SHEAR WALL TYPE
5/8"Ø EPOXY
ANCHOR WITH 5"
EMBED INTO
CONCRETE
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
GENERAL NOTES
S1.01469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
( 8136' - 10" )
( 8134' - 0" )
( 8128' - 10" )
( 8131' - 6" )
( 8125' - 0" )
( 8128' - 4" )
[ 8131' - 10" ]
[ 8142' - 8 1/2" ]
[ 8156' - 3" ]
[ 8155' - 9 1/4" ]( 8140' - 10" ) ( 8144' - 10" )FOOTING
STEP
FOOTING
STEP
( 8140' - 10" ) ( 8144' - 10" )FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
[ 8155' - 9 1/4" ][ 8145' - 6" ] WALL
STEP
TOP OF SLAB
TOP OF SLAB
8156' - 5 1/4"
TOP OF SLAB
8144' - 5 1/4"
TOP OF SLAB
8129' - 6"
8132' - 3"
TOP OF SLAB .SLOPERE: ARCH8" CONCRETE SLAB ON GRADE
WITH #5 AT 10" EACH WAY
5" CONCRETE SLAB ON GRADE
WITH 6X6 W2.1XW2.1 W.W.F.
WALL
STEP
WALL
STEP[ 8155' - 9 1/4" ][ 8155' - 9 1/4" ][ 8143' - 3 1/8" ] [ 8144' - 3" ] [ 8146' - 6" ]( 8125' - 0" ) ( 8128' - 4" ) ( 8132' - 10" ) ( 8136' - 10" )( 8126' - 6" )( 8128' - 4" ) FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
[ 8155' - 9 1/4" ]
FOOTING
STEP
1' - 10" 1' - 6"3' - 0"
10"1' - 0" 1' - 0" 2' - 4"10"2' - 10"1' - 0" 3' - 10"10"1' - 6"1' - 0" 8"1' - 6"1' - 6"
8"
2' - 3"
1' - 1"
10"
10" 1' - 6"10" 2" 8"
2' - 0"
2' - 4"
8"
4' - 0"
[ 8141' - 0" ]1' - 6"8"8" 1' - 0"8"BEAM POCKET
RE: 8/S4.1
5'-6" X 5'-6" X 1'-0"
CONCRETE FOOTING
WITH (6)-#5 EACH WAY
WALL
STEP
WALL
STEP
4'-0" X 4'-0" X 1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY( 8128' - 4" )[ 8131' - 7" ]4' - 0"2' - 0"2' - 0"
WALL
STEP
WALL
STEP
WALL
STEP
[ 8132' - 2" ][ 8132' - 2" ]
8156' - 5 1/4"
8" CONCRETE SLAB ON GRADE
WITH #5 AT 10" EACH WAY
2' - 0"
WALL
STEP
WALL
STEP
NOTE: BACKFILLING OF FOUNDATION
SHALL CONSIST OF A MINIMUM HORIZONTAL
WIDTH OF 2'-0" OF GEO-FOAM BACKFILL
MATERIAL PLACED AGAINST FOUNDATION WALL,
EXTENDING FROM FOOTING TO 18"
BELOW FINAL GRADING
8
S3.1
1
S3.1
5
S3.1
6
S3.1
2
S3.1
3
S3.1
4
S3.1
PERMANENT SHORING WALL
BY OTHERS
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"9' - 6" 14' - 0" 21' - 7 1/2"15' - 11 1/2"5' - 1 7/8" 5' - 6 1/8" 9' - 3 1/2" 22' - 4" 12' - 0 3/8" 17' - 11 1/4"
20' - 0 3/8" 18' - 0" 5' - 9 5/8"3' - 9"59' - 4" 15' - 1 1/2" 8' - 0" 4' - 0" 6' - 0" 12' - 10 1/4" 3' - 10 1/4" 3' - 6" 6' - 10" 2' - 2" 4' - 10 1/4" 7' - 3 1/4" 13' - 7 3/4"8' - 6 1/2"WALL
STEP
7 1/2"
4 1/2"3' - 6 1/4" 1' - 0"10" 2"6' - 10 1/2"
8" 5"
1' - 1"8"6" 7"
[ 8143' - 5 3/4" ]
[ 8144' - 3" ]
[8165'-10"]
WALL
STEP
[ 8143' - 9 1/4" ]
WALL
STEP
WALL
STEP
{ 8129' - 0" }{ 8129' - 0" }
[ 8128' - 4" ]1' - 0"S2.0
2
[ 8142' - 10 7/8" ]
FOOTING
STEP
[ 8142' - 10 7/8" ]
( 8131' - 6" )
RE: S2.1 FOR CONCRETE
WALL ABOVE FRAMING
TOW = 8165'-10"
BOW = 8143'-5 3/4"
8" CONCRETE
RE: S2.2
1' - 0" 3' - 5"1' - 0"
WALL
STEP 1' - 5 3/8" 2' - 8 3/4"EMBED PLATE
RE: 19/S4.1 (SIM.)
EMBED PLATE
RE: 19/S4.1 (SIM.)
1' - 6 7/8" 13' - 3 5/8" 2' - 8"
8131' - 6"
T.O.CONC
8
S3.2
5
S3.2
3
S3.2
RE: NOTE 17
8129' - 6"
T.O.CONC
8129' - 0"
T.O.CONC ( 8128' - 10" ) BEAM POCKET
4
S3.2
6 1/2" 1' - 8"7
S3.2 10"2' - 0"10"BEAM POCKET6' - 5 1/2"5' - 8" ( 8148' - 10" )
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
( 8128' - 4" )( 8131' - 6" )
FOOTING
STEP
FOOTING
STEP
( 8131' - 6" )FOOTING
STEP 5' - 6 3/4"[ 8143' - 0" ] [ 8156' - 3" ]11 5/8"
[ 8160' - 9 1/8" ]
WALL STEP
7' - 1 1/4"
FOUNDATION NOTES:
1. INDICATES ELEVATION OF TOP OF FLOOR SHEATHING OR TOP OF
CONCRETE SLAB.
2. ALL SLAB-ON-GRADES ARE 4” THICK WITH 6x6-W2.1 x W2.1 W.W.F, U.N.O.
3. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND DETAILS WITH
ARCHITECTURAL DRAWINGS.
4. [XXX’-XX”] INDICATES TOP OF FOUNDATION WALL (GRADE BEAM) ELEVATION.
5. (XXX’-XX”) INDICATES TOP OF FOOTING ELEVATION.
6. {XXX’-XX”} INDICATES TOP OF LEDGE ELEVATION.
7. GENERAL CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS LISTED IN SOILS
REPORT.
8. INDICATES TOP OF SLAB STEP.
9. ALL CONCRETE WALLS ARE 8" THICK, U.N.O.
10. CONTRACTOR TO PLACE (3)-#5 VERTICALLY FULL HEIGHT OF WALL AT HIGH SIDE OF
ALL WALL STEPS GREATER THAN 4’-0” IN ADDITION TO WALL REINFORCING SHOWN
OTHERWISE.
11. FOOTING ELEVATIONS SHOWN ARE MAXIMUMS AND MAY NEED TO BE LOWERED DUE
TO SOIL CONDITIONS. VERIFY CHANGES WITH STRUCTURAL ENGINEER OF
RECORD PRIOR TO CONSTRUCTION.
12. PROVIDE CONTROL JOINTS OR CONSTRUCTION JOINTS PER GENERAL NOTES.
MAXIMUM SIZE OF EACH AREA SHALL NOT EXCEED 144 SQUARE FEET.
CONTRACTOR TO COORDINATE JOINT LAYOUT WITH ARCHITECT.
13. ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER ARCHITECTURAL
LANDSCAPE PLANS, DETAILS, AND ELEVATIONS. SITE WALLS SHALL NOT BE
CONNECTED TO THE BUILDING UNLESS NOTED OTHERWISE.
14. GEO-FOAM BACK FILL MATERIAL SHALL BE CONTROL GEO-FOAM 12 AS
MANUFACTURED BY R-CONTROL. ALTERNATIVE SHALL MEET ASTM D6817
AND SHALL BE OF EQUAL DENSITY AND MODULES OF ELASTICITY AND
COMPRESSIVE RESISTANCE.
15. PROVIDE 1/2"X8"X8" EMBED PLATES WITH (4)-1/2"Ø X 4" H.A.S. AT 2'-0" FOR COLUMN
ATTACHMENT, RE:9/S3.2. (PLATES REQUIRED ABOVE ELEVATION = 8144'-3")
3 3.9
A
[ 8142' - 8 1/2" ][ 8143' - 3 1/8" ]
[ 8142' - 7 5/8" ]
STEP
BOW
STEP
BOW
( 8137' - 0" )
WALL
STEP
WALL
STEP
= BOW 10"6 1/2"2' - 9 5/8" 6' - 9 3/4" 1' - 1" 7' - 3 5/8" 5' - 9 5/8"
6 1/2" 6 1/2"
T.O.BEAM POCKET
18' - 0"
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT ENTRY
FOUNDATION PLAN
S2.01469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT ENTRY FOUNDATION PLANM ATCH LINE M ATC HLIN E1/4" = 1'-0"2
EAST UNIT ENTRY FOUNDATION
PLAN - TOP OF WALL
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
(2)-9 1/4" LVL
(2)-11 7/8" LVL (2)-11 7/8" LVLAT ROOF
AT STOREFRONT
(2)-9 1/4" LVL9 1/4" LVLAT 1'-4"9 1/4" LVL
AT 1'-4"
2X10
AT 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
UP ONLY UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
STAIR AND
ELEVATOR
TOP OF
CONCRETE
8144' - 5 1/4"
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
RE: S2.0
BEAM POCKET
HSS 5X5X3/8
8143'-8"
TOP OF
PLYWOOD
(3)-2X6
UP
ONLY
(3)-2X6 8144'-5 1/4"
TOP OF
PLYWOOD
8
S4.1
6
S4.1
12
S4.1
3
S4.1
7
S4.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"EMBED.
PLATE, TYP.
EMBED.
PLATE, TYP.W10X22< 8144' - 3" >W18X86< 8144' - 3" >W16X31
< 8144' - 3" >W10X26< 8144' - 3" > W10X26
< 8144' - 3" >W10X26< 8144' - 3" >W10X26< 8144' - 3" >2
S3.1
3
S3.1
1
S3.1
2X6 AT 1'-4" BEARING WALL 8143'-10 3/4"
TOP OF
PLYWOOD HSS16X4X1/4< 8144' - 5 1/4" >HSS16X4X1/4< 8144' - 5 1/4" >HSS16X4X1/4< 8144' - 5 1/4" >HSS 6X6X1/4
UP ONLY 6" CL SPLICEW10X30
< 8142' - 11 1/4" >
HSS12X8X1/4
< 8146' - 0" >
20
S4.1
HSS 6X6X1/4
UP AND
DOWN
HSS 6X6X1/4
UP AND
DOWN
5
S4.2
W8X31
< 8143' - 5 3/4" >W8X31< 8143' - 5 3/4" >16
S4.1
2
S4.2
4
S3.2
WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT GUEST
FLOOR FRAMING PLAN
S2.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT GUEST FLOOR FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
UP
ONLY
(3)-11 7/8" LVL
(3)-11 7/8" LVL2X10
AT 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
(2)-11 7/8" LVL
2X10
AT 1'-4"
UP
ONLY
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
8" CONCRETE SLAB-ON-GRAD
WITH #5 AT 10" EACH WAY
RE: S2.0
11 7/8" BCI-6000
AT 1'-4"
HSS 4X4X3/8
HSS 4X4X3/8
UP
ONLY
8" CONCRETE SLAB-ON-GRAD
WITH #5 AT 10" EACH WAY
RE: S2.0
8156' - 5 1/4"
TOP OF
CONCRETE
HSS 4X4X1/4
(3)-2X10(3)-2X10 HSS 4X4X1/4 (3)-9 1/4" LVL (3)-9 1/4" LVL 8156'-5 1/4"
TOP OF
PLYWOOD 6" CL SPLICEHSS 4X4X1/4
HSS 4X4X1/4
HSS 4X4X1/4 8155'-8"
TOP OF
PLYWOOD
(3)-2X6
HSS 4X4X1/4
(3)-2X6
2X6 AT 1'-4"
BEARING STUD WALL
2X6 AT 1'-4"
BEARING STUD WALL
(3)-2X6
HSS 8X8X1/4
UP AND DOWN
HSS 8X8X1/4
UP AND DOWN
STAIR AND
ELEVATOR
11
S4.1
6
S4.1
9
S4.1
4
S4.1
10
S4.1
4
S3.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"(3)-11 7/8" LVL HSS16X4X1/4< 8156' - 5" >W10X22< 8156' - 3" >HSS 6X6X1/4
UP AND DOWN
W14X43
< 8156' - 3" >W12X22< 8153' - 5 3/4" >HSS16X4X1/4< 8156' - 5" >HSS16X4X1/4< 8156' - 5" >SW1
SW1A
8156' - 5 1/4"
TOP OF
CONCRETE
8
S4.1SIM.W10X60< 8156' - 3" >W10X39
< 8156' - 3" >W10X26< 8156' - 3" >W10X54
< 8156' - 3" >1 3/4" X 11 7/8" LVL RIM 1 3/4" X 11 7/8" LVL RIMBEAM POCKET
RE: 8/S4.1 (SIM.)
BEAM POCKET
RE: 8/S4.1 (SIM.)
4
S3.2
HSS 6X6X1/4
UP AND DOWN
HSS 6X6X1/4
UP AND DOWN
5
S4.2
HSS4X4X1/4
3
S4.2
8
S3.1
UP
ONLY
UP
ONLY
SIMPSON HUC HANGER
WITH TITEN 1/4"ØX1 3/4"
SCREWS INTO CONCRETE
WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT LIVING
FLOOR FRAMING PLAN
S2.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT LIVING FLOOR FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
(3)-14" LVL(3)-16" LVL
14" LVL
SUB FASCIA
SUB FASCIA
14" LVL
SUB FASCIA
SUB FASCIA14" LVL (3)-14" LVL14" LVL SUB FASCIA14" LVL
(2)-14" LVL 0"14" LVL
AT 2'-0"(3)-16" LVL14" BCI60
AT 1'-0"
14" BCI60
AT 1'-4"
6' - 0"
5' - 0"(3)-14" LVL14" LVL SUB FASCIA14" LVL SUB FASCIA(3)-14" LVL(2)-14" LVLHSS8X6X3/814" LVL 14" LVL
14" LVL SUB FASCIASUB FASCIA
SUB FASCIA (2)-14" LVL14" LVL
AT 2'-0" 14" BCI60
AT 1'-4"
14" LVL
AT 2'-0"SLOPE SLOPESLOPE14" BCI60
AT 1'-4"
14" BCI60
AT 1'-0"
14" LVL
AT 2'-0"
14" LVL
14" LVL
SUB FASCIA
SUB FASCIA
2X6 AT 1'-4" BEARING WALL
14" LVL
AT 2'-0"
(2)-14" LVL
14" BCI60
AT 1'-0" 0"HSS 8X6X3/8HSS 8X6X3/8 (2)-14" LVLHSS 4X4X1/4
(3)-2X6
STUB COLUMN
6" SPLICEHSS 4X4X3/8
HSS 8X8X1/4HSS 8X8X1/4 2
S5.1
6
S5.1
3
S5.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"HSS 5X5X1/2HSS 5X5X1/2
10
S4.1 SIM.HSS 6X6X1/4 SW1SW1 SW1SW1SW1A
SW1ASW1A SW1A8167'-0 7/8"
TOP OF
PLYWOOD
RE: X/SX
(2)-14" LVL
HSS18X6X5/8
< 8172' - 1 5/8" >
HSS18X6X3/8
< 8165' - 6" >
W16X26
< 8167' - 4" >
W18X35
< 8167' - 6" >
W14X22
< 8165' - 9 3/4" >
W14X22
< 8165' - 3 5/8" >WALL ABOVEHSS8X6X3/8
< 8169' - 2 5/8" >
RE: S2.7 FOR WEST
UNIT ROOF FRAMING
RE: S2.7 FOR WEST
UNIT ROOF FRAMING
HSS 6X6X1/4
HSS 6X6X1/4 (2)-9 1/2" LVL (2)-9 1/2" LVL(2)-14" LVL(3)-9 1/2" LVL 13
S5.1
10
S5.1
WOOD ROOF FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURED BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CASCADE. ALTERNATES
SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X8 AT 2X6 WALLS OR (2)-2X8 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET S1.0
FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. RE: ARCHITECT FIR CHIMNEY SIZES AND LOCATIONS NOT NOTED ON STRUCTURAL PLANS.
21. OVERFRAMING SHALL BE 2X6 MINIMUM AND SHALL BE POSTED DOWN TO MAIN FRAMING ON
A GRID NOT TO EXCEED 4'-0" X 4'-0" (16FT2).
22. RE: ARCHITECTURAL DRAWINGS FOR ALL OVERLOW SCUPPER LOCATIONS.
23 INDICATES MONENT CONNECTION.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT ROOF
FRAMING PLAN
S2.31469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT ROOF FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
5 6 7 8 9
P
O
N
M
L
K
Q
J
I
H
( 8149' - 1" )
[ 8161' - 9" ][ 8161' - 9" ]( 8146' - 10" )( 8142' - 10" ) ( 8146' - 10" )( 8149' - 1" ) [ 8149' - 3 1/4" ] ( 8138' - 11 1/2" )
[ 8149' - 3 1/4" ]
( 8134' - 10" )( 8131' - 0" ) [ 8149' - 9" ][ 8149' - 3 1/4" ]
( 8134' - 10" )
[ 8149' - 9" ][ 8149' - 9" ] ( 8132' - 6" ) [ 8149' - 8 1/4" ] [ 8137' - 1" ]( 8134' - 4" ) ( 8132' - 6" )
[ 8137' - 1" ]
[ 8137' - 2" ]
( 8128' - 0" )( 8149' - 1" )[ 8161' - 9" ]( 8145' - 4" ) ( 8141' - 4" ) ( 8137' - 4" ) ( 8137' - 4" )( 8136' - 2" )( 8132' - 6" )( 8128' - 0" )[ 8149' - 9" ][ 8137' - 2" ]FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP FOOTING
STEP
WALL
STEP
FOOTING
STEP
FOOTING
STEP
( 8137' - 4" )
FOOTING
STEP
WALL
STEP
WALL
STEP 10"10"3' - 10 3/4"4' - 0"4' - 0" 2' - 6" 6' - 6" 10"2' - 0" TOP OF SLAB
.SLOPERE: ARCH5" CONCRETE SLAB ON GRADE
WITH 6X6 W2.1XW2.1 W.W.F.
FOOTING
STEP( 8134' - 10" )8149' - 3 1/4"2' - 0" 10" 4' - 0"2' - 0" 4' - 0"10" 2' - 0" 10" 4' - 0"8" 1' - 0"
10"
8" 1' - 0"
10"2' - 0" 5' - 0"10"( 8134' - 10" )[ 8149' - 3 1/4" ]1' - 0" 1' - 6"2' - 0"10"10"
1' - 0" 2' - 0"1' - 8"8"8"
1' - 0"
1' - 6" 1' - 6"
2' - 0"
10"2' - 3"2' - 3" 8"8" 1' - 0"8"PERMANENT SHORING WALL
BY OTHERS
1
S3.1
5
S3.1
6
S3.1
1
S3.1
2
S3.1
7
S3.1
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
NOTE: BACKFILLING OF FOUNDATION
SHALL CONSIST OF A MINIMUM HORIZONTAL
WIDTH OF 2'-0" OF GEO-FOAM BACKFILL
MATERIAL PLACED AGAINST FOUNDATION WALL,
EXTENDING FROM FOOTING TO 18"
BELOW FINAL GRADING
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" 18' - 6" 18' - 7 1/2" 17' - 4 1/2" 7' - 6"2' - 6"6' - 6" 18' - 6" 24' - 0" 9' - 4 7/8" 3' - 8"1' - 0 7/8"
4' - 2"8' - 10 1/4"WALL
STEP
( 8137' - 0" )
TOP OF SLAB
8137' - 9"1' - 8" 1' - 6" 1' - 8" 2"10" [ 8134' - 4" ]
{ 8135' - 0" }
FOOTING
STEP
8135' - 6"
1
S3.2
2
S3.2
10"Ø CONC. PIER WITH
28"Ø BELLED FOOTING
(BIGFOOT OR EQUAL)8"( 8137' - 4" )
2"
S2.4
2
5'-6"X5'-6"X1'-0"
CONCRETE FOOTING
WITH (6)-#5 EACH WAY
BEAM
POCKET
8'-0"X8'-0"X1'-0" CONCRETE
FOOTING WITH #5 AT 1'-0"
EACH WAY
8137' - 0"
T.O.CONC
8
S3.2
8135'- 6"
T.O.CONC
8135' - 6"
T.O.CONC
8135' - 0"
T.O.CONC
4'-0"X4'-0"X1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY
4'-0"X4'-0"X1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY
17' - 9 1/2" 30' - 1 1/4" 13' - 5 1/4"
5' - 11 1/4" 18' - 0"6' - 2"
( 8131' - 0" )
6
S3.2
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.5 5' - 4 3/4" 7 1/4" 7 1/4"
7 1/4" 15' - 8 1/4" 1' - 3 1/4" 2' - 6 1/8"11' - 4 3/4"4' - 5" 13' - 11 1/4"1 3/4"EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
WALL
STEP
4"8 1/2"{ 8135' - 0" }4' - 1 5/8"[ 8134' - 4" ]3'-0" X 6'-2"
OPENING
(VERIFY WITH ARCH.)
FOUNDATION NOTES:
1. INDICATES ELEVATION OF TOP OF FLOOR SHEATHING OR TOP OF
CONCRETE SLAB.
2. ALL SLAB-ON-GRADES ARE 4” THICK WITH 6x6-W2.1 x W2.1 W.W.F, U.N.O.
3. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND DETAILS WITH
ARCHITECTURAL DRAWINGS.
4. [XXX’-XX”] INDICATES TOP OF FOUNDATION WALL (GRADE BEAM) ELEVATION.
5. (XXX’-XX”) INDICATES TOP OF FOOTING ELEVATION.
6. {XXX’-XX”} INDICATES TOP OF LEDGE ELEVATION.
7. GENERAL CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS LISTED IN SOILS
REPORT.
8. INDICATES TOP OF SLAB STEP.
9. ALL CONCRETE WALLS ARE 8" THICK, U.N.O.
10. CONTRACTOR TO PLACE (3)-#5 VERTICALLY FULL HEIGHT OF WALL AT HIGH SIDE OF
ALL WALL STEPS GREATER THAN 4’-0” IN ADDITION TO WALL REINFORCING SHOWN
OTHERWISE.
11. FOOTING ELEVATIONS SHOWN ARE MAXIMUMS AND MAY NEED TO BE LOWERED DUE
TO SOIL CONDITIONS. VERIFY CHANGES WITH STRUCTURAL ENGINEER OF
RECORD PRIOR TO CONSTRUCTION.
12. PROVIDE CONTROL JOINTS OR CONSTRUCTION JOINTS PER GENERAL NOTES.
MAXIMUM SIZE OF EACH AREA SHALL NOT EXCEED 144 SQUARE FEET.
CONTRACTOR TO COORDINATE JOINT LAYOUT WITH ARCHITECT.
13. ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER ARCHITECTURAL
LANDSCAPE PLANS, DETAILS, AND ELEVATIONS. SITE WALLS SHALL NOT BE
CONNECTED TO THE BUILDING UNLESS NOTED OTHERWISE.
14. GEO-FOAM BACK FILL MATERIAL SHALL BE CONTROL GEO-FOAM 12 AS
MANUFACTURED BY R-CONTROL. ALTERNATIVE SHALL MEET ASTM D6817
AND SHALL BE OF EQUAL DENSITY AND MODULES OF ELASTICITY AND
COMPRESSIVE RESISTANCE.
15. PROVIDE 1/2"X8"X8" EMBED PLATES WITH (4)-1/2"Ø X 4" H.A.S. AT 2'-0" FOR COLUMN
ATTACHMENT, RE:9/S3.2. (PLATES REQUIRED ABOVE ELEVATION = 8144'-3")
J
I
STEP
BOW
STEP
BOW
[ 8149' - 6 3/4" ]
( 8143' - 0" )
18' - 0" 5' - 4"
BEAM
POCKET
[ 8143' - 0" ]B.O.W.9' - 4 3/4"
1' - 2"
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT ENTRY
FOUNDATION PLAN
S2.41469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT ENTRY FOUNDATION PLANMATC HLI NE MATC HLI NE1/4" = 1'-0"2
WEST UNIT ENTRY FOUNDATION
PLAN - TOP OF WALL
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
5 6 7 8 9
P
O
N
M
L
K
Q
J
I
H
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
2X10
AT 1'-6"
(TREATED)
6X6 POST(2)-11 7/8" LVLUP
ONLY
UP
ONLY
HSS 4X4X3/8
1/4" PLATE
STEEL SADDLE
11 7/8" BCI-6000
AT 1'-4"11 7/8" BCI-6000
AT 1'-4"
UP
ONLY
UP
ONLY
2X10
AT 1'-6"
(TREATED)
HSS 4X4X1/4
UP AND DOWN
2X6 AT 1'-4"
BEARING STUD WALL
HSS 5X5X3/8 DOWN
HSS 5X5X1/4 UP
(3)-2X6
HSS 4X4X1/4
HSS6X6X1/4
UP ONLY
UP
ONLY
HSS12X8X1/4
OVER (3)-16" LVL AT ROOF LEVEL
EXTERIOR GLASS
WALL ABOVE
9 1/4" LVL
AT 1'-4"(2)-9 1/4" LVL9 1/4" LVL
AT 1'-4"
HSS 4X4X3/16 HSS 4X4X3/16
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
STAIR AND
ELEVATOR
8149'-11 1/4"
TOP OF
CONCRETE
8149'-11 1/4"
TOP OF
PLYWOOD
8149'-2"
TOP OF
PLYWOOD
HSS 4X4X1/4
7
S3.1
2
S3.1
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" (2)-2X10(2)-2X10
8149'-6"
TOP OF
DECKING
W18X86< 8149' - 9" >W16X26
< 8149' - 9" >
W10X30
< 8148' - 5 1/4" >
8149'-4 3/4"
TOP OF
PLYWOOD
2X6 AT 1'-4" BRG. WALL
HSS16X4X1/4< 8149' - 10 1/2" >HSS16X4X1/4< 8149' - 10 1/2" >HSS16X4X1/4< 8149' - 10 1/2" >HSS4X4X1/4
(2)-11 7/8" LVL
15
S4.1
16
S4.1
14
S4.1
BEAM POCKET
WITH C9X15
EMBED PLATE
RE: 19/S4.1 (SIM.)
8
S4.1
4
S4.2
5
S4.2
1
S3.2
1
S4.2
6
S3.2
HSS6X6X1/4
UP AND DOWN
HSS6X6X1/4
UP AND DOWN
2
S3.2
(2)-11 7/8" LVLWOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT GUEST
FLOOR FRAMING PLAN
S2.51469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT GUEST FLOOR FRAMING PLANMATC HLI NE MATC HLI NERevisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
3.9 4
5 6 7 8 9
E
D
C
P
O
N
M
L
K
Q
J
I
H
HSS 4X4X1/4
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY2 3/4"2 3/4"2 3/4"HSS 5X5X3/8
(2)-11 7/8" LVL
HSS 6X6X1/4
UP AND DOWN
(3)-11 7/8" LVL
(3)-2X6
2X6 AT 1'-4"
BEARING WALL
STONE VENEER
ABOVE
STONE VENEER
ABOVE
HSS 5X5X1/4 UP
ONLY
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
HSS 4X4X1/4
HSS 4X4X3/8
11 7/8" BCI-60
AT 1'-4"
9 1/2" BCI-6000
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
EXTERIOR
STUD WALL ABOVE
EXTERIOR
STUD WALL ABOVE
2X6 AT 1'-4"
BEARING STUD WALL
11 7/8" BCI-60
AT 1'-4"(2)-11 7/8" LVLSTAIR AND
ELEVATOR
8161'-11 1/4"
TOP OF
PLYWOOD
5
S4.1 SIM.4
S3.1
7
S3.1
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" W10X15< 8160' - 11 3/4" >W8X21
< 8160' - 11 3/4" >
W10X39
< 8160' - 11 3/4" >
8161'-2"
TOP OF
PLYWOOD W10X88 < 8161' - 9" >W16X31
< 8161' - 9" >
W12X35
< 8161' - 9" >
W10X22
< 8161' - 9" >W10X45< 8161' - 9" >W10X45
< 8161' - 9" >
W10X22
< 8161' - 9" > W10X39< 8161' - 9" >W10X39< 8161' - 9" >(2)-11 7/8" LVL
< 8161' - 9" >W10X22< 8161' - 9" >11 7/8" BCI-60AT 1'-4"W10X19
< 8161' - 9" >
W10X19
< 8161' - 9" >
HSS4X4X1/4
(2)-11 7/8" LVL W16X26
EMBED PLATE
RE: 19/S4.1
EMBED PLATE
RE: 19/S4.1
19
S4.1
1
S4.1
5
S4.1
HSS8X8X1/4HSS8X8X1/4 HSS16X4X1/4< 8161' - 10 1/2" >HSS16X4X1/4< 8161' - 10 1/2" >HSS16X4X1/4< 8161' - 10 1/2" >HSS8X6X5/8
UP
HSS4X4X1/4
DOWN
EMBED PLATE
RE: 19/S4.1
9 1/2" BCI-6000
AT 1'-4"
(3)-11 7/8" LVL
HSS4X4X1/4
1
S4.1
EMBED PLATE
RE: 19/S4.1
EMBED PLATE
RE: 19/S4.1
HSS 6X6X1/4
UP AND DOWN
HSS 6X6X1/4
UP AND DOWN
5
S4.2 (2)-9 1/2" LVL2
S3.2
1
S3.2
HSS4X4X1/4
UP
ONLY
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
7
S3.1
(SIM.)UP
ONLY
UP
ONLY
2X6 AT 1'-4" BEARING WALL
6
S4.2
UP
ONLY
UP
ONLY WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT LIVING
FLOOR FRAMING PLAN
S2.61469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT LIVING FLOOR FRAMING PLANMATC HLI NE MATC HLI NERevisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
3.9 4
5 6 7 8 9
E
D
C
P
O
N
M
L
K
Q
J
I
H
OR W14X22
(2)-14" LVL(2)-14" LVL(2)-14" LVL
HSS20X8X5/8 (2)-9 1/2" LVL
(2)-9 1/2" LVL (2)-9 1/2" LVL(2)-9 1/2" LVL DOUBLE 14" BCI-90
AT 2'-0"
DOUBLE 14" BCI-90
AT 2'-0"
9 1/2" LVL
AT 2'-0"
9 1/2" LVL
AT 2'-0"
9 1/2" BCI-6000
AT 1'-4"(2)-14" LVL (3)-9 1/2" LVL (2)-9 1/2" LVL (3)-9 1/2" LVL (3)-9 1/2" LVL
HSS 4X4X1/4HSS 4X4X1/4
(2)-14" LVL 0"14" LVL
AT 2'-0"
14" BCI-90
AT 2'-0"
STUB COLUMN
14" LVL
AT 2'-0"
DOUBLE 14" BCI-90
AT 2'-0"(2)-14" LVL(2)-14" LVLHSS 8X8X1/4 HSS 8X8X1/4
14" BCI-90
AT 2'-0"
14" LVL
AT 2'-0"
(3)-2X6
2X6 AT 1'-4" BRG. WALL
14" LVL
AT 2'-0"
(3)-2X6 (3)-2X6
(3)-2X6 (3)-2X6
DOUBLE 16" BCI-90
AT 2'-0" 0"AT TRANSOM 0"AT TRANSOM
HSS 10X6X3/8
HSS 10X6X3/8
(3)-11 7/8" LVL(3)-11 7/8" LVL 0" 0"4
S5.1
2 3/8"2 3/8"18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" (3)-16" LVL
(3)-16" LVL
(2)-14" LVL (2)-14" LVL
HSS 8X6X5/8
HSS 5X5X1/2
8173'-5 1/2"
TOP OF
PLYWOOD
(3)-11 7/8" LVL (3)-11 7/8" LVLSW1 SW1SW1ASW12/129 1/2" LVL
SUBFASCIA
8171'-11 1/4"
TOP OF
PLYWOOD
9 1/2" LVL
SUBFASCIA SW1(2)-9 1/2" LVL 0"
18
S4.1
7
S5.1
8
S5.1
W18X40
< 8177' - 6 3/8" >
HSS8X6X3/8
< 8171' - 0" >
HSS8X6X3/8
< 8171' - 0" >
W14X22
< 8177' - 1 3/8" >WALL ABOVEHSS8X6X3/8
< 8176' - 2 5/8" >
W12X26
< 8173' - 4 3/4" >
W12X26
< 8175' - 8 7/8" >
W12X30
< 8175' - 8 7/8" >
W12X26
< 8175' - 8 7/8" >
W18X40
< 8171' - 11 7/8" >2:12HSS4X4X3/8
HSS8X6X5/8
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
12
S5.1
(3)-9 1/2" LVL(3)-11 7/8" LVL STUB
COLUMNSW1ASW1A5
S5.1
(2)-14" LVL(2)-14" LVL13
S5.1
5
S5.1
11
S5.1
10
S5.1
9
S5.1
WOOD ROOF FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURED BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CASCADE. ALTERNATES
SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X8 AT 2X6 WALLS OR (2)-2X8 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET S1.0
FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. RE: ARCHITECT FIR CHIMNEY SIZES AND LOCATIONS NOT NOTED ON STRUCTURAL PLANS.
21. OVERFRAMING SHALL BE 2X6 MINIMUM AND SHALL BE POSTED DOWN TO MAIN FRAMING ON
A GRID NOT TO EXCEED 4'-0" X 4'-0" (16FT2).
22. RE: ARCHITECTURAL DRAWINGS FOR ALL OVERLOW SCUPPER LOCATIONS.
23 INDICATES MONENT CONNECTION.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT ROOF
FRAMING PLAN
S2.71469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT ROOF FRAMING PLANMATC HLI NE MATC HLI NERevisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
RE: PLAN
RE: PLAN
2"3"CLR.RE: PLAN3" CLR.2" CLR.
RE: PLAN 1'-0" 7"
1'-1"2'-6"10"10"RE:PLAN
1'-0"10"RE: PLAN8"1'-0"
RE: PLAN1'-0"2" CLR.
10"1'-0"1'-0"1'-0" 1'-0"RE: PLAN
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL
AND HORIZONTAL
RE: PLAN
TOP OF
PLYWOOD
1 1/2" CONCRETE
TOPPING
EXTERIOR STUD WALL WITH
SHEATHING
2X TREATED PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
EXPOSED CONCRETE
FINISH RE: ARCH.
[XXX'-XX"]
RE: PLAN
(XXX'-XX")
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
#5 AT 1'-4" X 2'-6"1'-0"
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4 EACH WAY TOP
(2)-#5
RE: PLAN
(XXX'-XX")
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
#5 AT 1'-4" X 4'-0" 1'-6"
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4 EACH WAY TOP
(2)-#5
[XXX'-XX"]
RE: PLAN
TOP OF
CONCRETE
(2)-#5 TOP AND BOTTOM
FLOOR JOIST RE: PLAN
TREATED 2X10 WITH
1/2" Ø X 5" TITEN HD
CONCRETE SCREW ANCHOR
AT 2'-0"
#5 AT 1'-0" VERTICAL AND
HORIZONTAL
1 1/2" CONCRETE TOPPING
#5 AT 2'-0" X
2'-0"2'-0"8" CONCRETE SLAB-ON
GRADE
[XXX'-XX"]
RE: PLAN
TOP OF
CONCRETE
(2)-#5 TOP AND BOTTOM
FLOOR JOIST RE: PLAN
TREATED 2X10 WITH
1/2" Ø X 5" TITEN HD
CONCRETE SCREW ANCHOR
AT 2'-0"
#5 AT 1'-0" VERTICAL AND
HORIZONTAL
1 1/2" CONCRETE TOPPING
#5 AT 2'-0" X
2'-0"2'-0"8" CONCRETE SLAB-ON
GRADE
(XXX'-XX")
#5 AT 8" X 4'-0"1'-6"
#5 AT 1'-4 EACH WAY TOP
(2)-#5
5/8" Ø THREADED INSERT
AT 2'-0"
5/8" Ø X 2'-6" THREADED
ROD AT 2'-0"
8" CONCRETE SLAB
RE: PLAN
RE: PLAN
(XXX'-XX")
PARTY WALL RE: ARCH.
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR
BOLTS AT 2'-6"
RE: PLANRE: PLAN
TOP OF SLAB
{XXX'-XX"}
8" SLAB
RE: PLAN
#5 AT 1'-4" VERTICAL AND
HORIZONTAL EACH FACE
#5 AT 1'-4" X
EACH FACE 2'-6"1'-0"
2X4 FURRING WALL
TREATED 2X4 PLATE WITH
1/2" Ø X 10" ANCHOR BOLT
AT 2'-6"
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
SLOPE
#5 AT 1'-4" EACH WAY
(2)-#5 TOP AND
BOTTOM
DRIVEWAY BY
OTHERS
[XXX'-XX"]
CONSTRUCTION
JOINT
#5 AT 1'-4" HORIZONTAL
EACH FACE
#5 AT 1'-4" X
FULL HEIGHT1'-2"
#5 AT 1'-4" X
AS SHOWN1'-2"
(XXX'-XX")
#5 CONT.
DRIVEWAY BY
OTHERS
[XXX'-XX"]
#5 AT 1'-4" EACH FACE
#5 AT 2'-0" X
#5 AT 1'-4" X
EACH FACE
(XXX'-XX")
2'-0"2'-0"FULL HEIGHT1'-0"
SLAB-ON-GRADE
RE: PLAN
SLOPE
RE: ARCH.
(XXX'-XX")
5/8" Ø THREADED INSERT
AT 2'-0"
5/8" Ø X 2'-6" THREADED
ROD AT 2'-0"
8" CONCRETE SLAB
RE: PLAN
RE: PLAN
#5 AT 8" X
#5 AT 1'-0" TRANSVERSE
#5 AT 1'-4" LONGITUDINAL4'-0"2'-6"
(2)-#5
CONT.
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
RE: PLAN
TOP OF
PLYWOOD
1 1/2" CONCRETE
TOPPING
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
[XXX'-XX"]
2X TREATED PLATE WITH
1/2" Ø X 10" ANCHOR BOLT AT 2'-6"
WATERPROOFING AND FLASHING
RE: ARCH.
CONCRETE PATIO RE: ARCH.
(2)-#5 TOP AND BOTTOM
EXTERIOR WALL WITH
SHEATHING
SECTION 8
3/4" = 1'-0"
RE: PLAN
TOP OF
CONCRETE
[XXX'-XX"]
8" CONCRETE SLAB
RE: PLAN
FINISH FLOOR
RE: ARCH.
2X6 TREATED PLATE WITH
1/2" Ø ANCHOR BOLTS AT 2'-6"
PATIO RE: ARCH.
(XXX'-XX")
#5 AT 1'-4" HORIZONTAL
#5 AT 1'-0" VERTICAL
#5 AT 1'-0" X 2'-6"1'-2"
#5 AT 1'-4"
(2)-#5 TOP AND BOTTOM
(5)-#5 CONT.
RIGID INSULATION
.
.
.
.
.
.
.
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FOUNDATION
SECTIONS
S3.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
RE: PLAN1'-0"2'-0" (MIN.)
GEOFOAM BACKFILL
RE: PLAN
2" CLR.1'-6" MIN.RE: PLAN1'-0" 2'-0" (MIN.)
GEOFOAM BACKFILL
RE: PLAN1'-6" MIN. 2" CLR.3/4"3/4" 1'-3" 1'-1" 1'-8"1'-0"8"3/4"RE: PLAN1'-0"2"
CLR.10"2'-0"
1" MAX. OFFSET
(CENTERLINE OF COLUMN-
CENTERLINE OF PIER)4'-0" MIN.8"MIN.1'-6" MIN.8" MIN.3"MIN.9"1'-0"8" MIN.1 1/2"5" 1 1/2" 5"
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
EXTERIOR WALL WITH
SHEATHING
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"RE: PLAN
TOP OF
CONCRETE
FINISH FLOOR
RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(XXX'-XX")
[XXX'-XX"]
#5 AT 1'-4" X
2'-0"2'-0"
#5 AT 1'-4" VERTICAL
AND HORIZONTAL
(2)-#5 TOP AND BOTTOM
(5)-#5 CONT.
#5 AT 1'-4" X 2'-6"1'-2"
#5 AT 1'-4"
(XXX'-XX")
(5)-#5 CONT.
RE: PLAN
TOP OF
CONCRETE
EXTERIOR WALL WITH
SHEATHING
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
RE: PLAN
TOP OF
PLYWOOD
FLOOR SHEATHING
FINISH FLOOR
RE: ARCH.
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
FINISH FLOOR
RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(2)-#5 TOP AND BOTTOM
5/8" Ø X 2'-6" THREADED ROD
AT 2'-0"
5/8" Ø THREADED INSERT
AT 2'-0"#5 AT 1'-4" X
#5 AT 1'-4"2'-6"1'-2"
RE: PLAN
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
TOP OF
CONCRETE
(XXX'-XX")
{XXX'-XX"}
CONSTRICTION JOINT
ACCEPTABLE AT THIS
ELEVATION
[XXX'-XX"]
#5 AT 1'-0" VERTICAL
AND HORIZONTAL
(2)-#5 TOP AND BOTTOM
RE: PLAN
TOP OF PLYWOOD
FLOOR JOIST RE: PLAN WITH
SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL AND
HORIZONTAL EACH FACE
VARIES
TOP OF CONCRETE
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
#5 AT 1'-4"
(4)-#5 CONT.
2X TOP PLATE WITH 1/2" Ø X 10"
ANCHOR BOLTS AT 2'-6"
#5 X 4'-0" DOWEL AT 1'-0"
SECTION 4
3/4" = 1'-0"
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
FINISH FLOOR RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
#5 AT 1'-4" X
2'-0"2'-0"
(XXX'-XX") #5 AT 1'-4"
(5)-#5
#5 AT 1'-4" X 2'-6" 1'-6"
WATERPROOFING
AND DRAINBOARD
RE: ARCH.
SLIP JOINT
PATIO RE: ARCH.
2X6 BEARING WALL
RE: PLAN
#5 AT 2'-0" X
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
VARIES
TOP OF
CONCRETE2'-0"2'-0"
3" CONCRETE TOPPING
SLAB WITH 6X6 W2.1XW2.1
W.W.F. (RE: ARCH. FOR
CONTROL JOINT LAYOUT)
SLAB-ON-GRADE
RE: PLAN
RE: PLAN
(2)-#5 TOP AND BOTTOM
#5 AT MID-HEIGHT
#5 AT 1'-4" X
(ALTERNATE
HOOK)FULL HGT.8"
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN
10" Ø CONCRETE PIER WITH
28" Ø BIGFOOT FOOTING
SIMPSON ABA66
6X6 COLUMN (NOTCH FOR
(2)-2X10 BEARING) WITH
(2)-1/2" Ø THRU-BOLTS
#3 TIES AT TOP, MID-HEIGHT
AND BOTTOM
(4)-#5 X
FULL HGT.6"
3" STONE AND GROUT
RE: ARCH.
5" SLAB-ON-GRADE
RE: PLAN VERIFY WATERPROOFING,
DRAINBOARD AND TREAD/
RISER DIMENSIONS WITH
ARCHITECT.
#4 AT EACH NOSE
DRIVEWAY BY OTHERS
#5 AT 1'-0"
EACH WAY
RE: PLAN
TOP OF
CONCRETE
RE: PLAN
TOP OF CONCRETE
FOOTING RE: PLAN FOR SIZE
AND REINFORCING AT ELEVATOR
3" CONCRETE TOPPING SLAB
WITH 6X6 W2.1XW2.1 W.W.F.
(RE: ARCH. FOR CONTROL JOINT
LAYOUT)
SLAB-ON-GRADE
RE: PLAN
6"
HSS COLUMN RE: PLAN
1/2" X 8" X 8" EMBED
PLATE AT 2'-0"
CONCRETE WALL RE: 3/S3.2
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FOUNDATION
SECTIONS
S3.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1'-0"
6 1/2"1 1/2"1 1/2"3" 3"3 1/2"
6"5 3/4"10"1'-0"5 3/4"6 1/4"3 1/2"
6" 1 1/2"CLR.1 1/2"
CLR.2"2 1/2" 2 1/2" 2 1/2"
10" 1 1/2"1 1/2"3/4"3"3/4"4"6" 2" 2" 4" 2"3/4"4 3/4"
6 1/2"
A
A
B
B
A
SECTION 20
3/4" = 1'-0"
SECTION 19
3/4" = 1'-0"
SECTION 18
3/4" = 1'-0"
SECTION 17
3/4" = 1'-0"
SECTION 15
3/4" = 1'-0"
SECTION 14
3/4" = 1'-0"
SECTION 13
3/4" = 1'-0"
SECTION 12
3/4" = 1'-0"
SECTION 11
3/4" = 1'-0"
SECTION 10
3/4" = 1'-0"
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
1/4
3/4" X 5 3/4" X 10 1/4"
END PLATE WITH (4)-
3/4" Ø BOLTS
3/4" END PLATE
(2)-1/2" Ø X 10" ANCHOR
BOLT AND NON-SHRINK
GROUT
STEEL BEAM RE: PLAN
3/8" X 2 1/2" HORIZONTAL
STIFFENER EACH SIDE OF WEB
(ALIGN WITH BOTTOM FLANGE
OF W10 BEAM)
FOUNDATION WALL
RE: 12/S4.1
14KIP BOLT PRETENSION
REQUIRED FOR END PLATE
CONNECTION BOLTS
1/4
BOTH
SIDES
2X TOP PLATE WITH 1/2" Ø THRU-
BOLTS AT 2'-0"
CJP
CJP TOP
AND BOTTOM
RE: PLAN
TOP OF
PLYWOOD
EXTERIOR WALL WITH
SHEATHING
LVL BEAM RE: PLAN
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. STONE AND
GROUT
FLOOR JOIST RE: PLAN
WITH SIMPSON IUT HANGER
RE: PLAN
TOP OF
PLYWOOD
RE: PLAN
TOP OF
PLYWOOD
EXTERIOR WALL WITH
SHEATHING
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. STONE AND
GROUT ON TAPERED
FLOOR JOIST RE: PLAN
WITH SIMPSON IUT HANGER
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN WITH 2X
TOP PLATE WITH 1/2" Ø BOLTS AT
2'-0" AND SOLID WEB PACK WITH
1/2" Ø THRU-BOLTS AT 1'-4"
STAGGER TOP AND BOTTOM
(2)-1/2" Ø X 10" ANCHOR BOLTS
WITH SHIM AND GROUT
STEEL BEAM RE: PLAN
3/8" WEB STIFFENER
(2)-1/2" Ø X 10" ANCHOR
BOLTS WITH SHIM AND
GROUT
SECTION A-A
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6" WITH SLOTTED HOLES
IN BOTTOM FLANGE OF BEAM
RE: PLAN
TOP OF
PLYWOOD
<XXX'-XX">
[XXX'-XX"]
<XXX'-XX">
(2)-L4X3 1/2X5 1/2" WITH
(2)-3/4" Ø BOLTS EACH LEG
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø THRU-
BOLTS AT 2'-0" STAGGER
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS
HANGER
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
(2)-1/2" Ø X 10" ANCHOR
BOLTS
FOUNDATION WALL
RE: XXXXX
8" CONCRETE SLAB RE: PLAN<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
[XXX'-XX"]
SECTION B-B
[XXX'-XX"]
SHIM AND GROUT
1/2" X 5" X 9" CAP PLATE
HSS COLUMN RE: PLAN
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT
2'-0" STAGGER
<XXX'-XX">
FLOOR SHEATHING
RE: PLAN
TOP OF PLYWOOD
3/8" WEB STIFFENER EACH SIDE
1/4 2"BOTH SIDES
1/2" X 5" X 9" CAP PLATE
HSS COLUMN RE: PLAN
(2)-L4X3 1/2X3/8 X 5 1/2" WITH
(2)-3/4" Ø BOLTS EACH LEG
3/8" END PLATE
3/8" WEB STIFFENER
STEEL BEAM RE: PLAN
1/2" X 6" X 1'-4" HORIZONTAL
STIFFENER WITH (2)-3/4" Ø
BOLTS SLOTTED FOR WEB
L4X4X1/4 X 5"
<XXX'-XX">
1/4 2"
<XXX'-XX">
1/4 BOTH SIDES
RE: PLAN
TOP OF
PLYWOOD
3/8" WEB STIFFENER
FLOOR SHEATHING
1/4 2" AT 6"BOTH SIDES
FLOOR SHEATHING
FLOOR JOIST RE: PLAN
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
#6 AT 1'-0" EACH FACE
RE: PLAN
TOP OF
PLYWOOD
[XXX'-XX"]
(4)-#6 TOP
SOLID BLOCKING BETWEEN
JOISTS
(XXX'-XX")
(6)-#6 BOTTOM
#3 STIRRUPS AT 1'-0"
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
HSS COLUMN RE: PLAN
3/8" X 4" X 8 1/2" SHEAR PLATE
WITH (3)-3/4" Ø BOLTS
CJP TOP AND
BOTTOM FLANGE
HSS COLUMN RE: PLAN
1/2" X 6" X 10" BASE PLATE
WITH (4)-3/4" Ø BOLTS
STEEL BEAM RE: PLAN
LVL BEAM RE: PLAN
HSS BEAM RE: PLAN
3/8" X 8" X 10" PLATE
WITH (4)-3/4" Ø THRU-BOLTS
1/4
BOTH
SIDES 2 1/2"4" SECTION 16
3/4" = 1'-0"
EXTERIOR WALL WITH
SHEATHING
FINISH FLOOR RE: ARCH.
FLOOR JOIST RE: PLAN
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0" AND
SOLID WEB BLOCKING WITH
(2)-1/2" Ø THRU-BOLTS AT 1'-4"
RE: PLAN
TOP OF
PLYWOOD
WATERPROOFING
AND DRAINBOARD
RE: ARCH.
3" MAX. TILE AND GROUT
ON TAPERED INSULATION
RE: ARCH.
DECK JOIST RE: PLAN
WITH SIMPSON LUS HANGER
1/2" Ø THREADED STUDS AT
2'-0" (STAGGER) FOR 2X NAILER
AT TOP, BOTTOM AND SIDES
OF FRAME MEMBERS
CJP
RE: PLAN FOR
FRAME SIZES
RE: PLAN FOR BEAM SIZES
HSS COLUMN RE: PLAN
3/8" X 4" X 8 1/2" SHEAR PLATE
WITH (3)-3/4" Ø BOLTS
3/16
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
STAGGER
3/8" X 4" X 6" SHEAR PLATE
WITH (2)-3/4" Ø BOLTS
3/4" X 8" X 1'-0" EMBED
PLATE WITH (4)-5/8" Ø
WITH 5" EMBED
<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
FINISH FLOOR RE: ARCH.
FLOOR SHEATHING
1/4
[XXX'-XX"]
PATIO RE: ARCH.
FOUNDATION WALL
RE: 7/S3.1
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0"
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
FLOOR FINISH RE: ARCH.
FLOOR SHEATHING
LVL BEAM RE: PLAN
WITH (4)-3/4" Ø BOLTS
WEB BLOCKING AS
REQUIRED
[XXX'-XX"]
<XXX'-XX">
3" MAX. STONE AND GROUT
WATERPROOFING AND
DRAINBOARD RE: ARCH. ON
TAPERED INSULATION
3/4" DECK SHEATHING
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN
WALL BEYOND
FOUNDATION WALL RE: 12/S4.1
RE: PLAN
TOP OF
PLYWOOD
FLAT ROOF WATERPROOFING
AND DRAINBOARD RE: ARCH.
3" MAX. GRAVEL BALLAST
5/8" ROOF SHEATHING
ROOF JOIST
RE: PLAN
TREATED 2X6 WITH 1/2" Ø X 10"
ANCHOR BOLTS AT 2'-6"
WALL BEYOND
[XXX'-XX"]
INSULATION RE: ARCH.
C SPLICEL
.
.
.
.
.
.
.
.
.
.
.
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FLOOR FRAMING
SECTIONS
S4.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
3"3 1/4" 3" 1 1/2"4 1/2" 2"1 1/2"1 1/2" 3" 2 5/8" 2 7/8"
3" TYP.EQ.EQ. A A
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN WITH
SIMPSON LUS HANGER
WOOD BEAM WITH CHANNEL
WITH (2)-1/2" Ø THRU-BOLTS
AT 1'-4"
2X DECKING RE: ARCH.
RE: PLAN
TOP OF
PLYWOOD
DECK JOIST RE: PLANSTEEL BEAM RE: PLAN WITH 1/2" Ø X 6"
H.A.S. AT 6"
3" MAX. STONE AND GROUT
RE: ARCH.
WATERPROOFING AND
DRAINBOARD RE: ARCH.
ON TAPERED INSULATION
8" CONCRETE WALL
WITH #5 AT 1'-4"
VERTICAL AND
HORIZONTAL
(2)-#5 TOP AND BOTTOM
HSS BEAM RE: PLAN WITH
1/4" END PLATE EACH END TYP.
HSS COLUMN RE: PLAN
3/8" X 3" X 1'-0"
WITH (3)-3/4" Ø BOLTS
1/4
FRAMING AT ELEVATOR
SECTION A-A
DECK FRAMING RE: PLAN
1/4" X 6" X 8" PLATE WITH
(2)-1/2" Ø THRU-BOLTS
HSS COLUMN RE: PLAN
WATERPROOFING AND
DRAINBOARD ON TAPERED
INSULATION RE: ARCH.
3" MAX. TILE AND GROUT
LVL BEAM RE: PLAN
3/8" X 5 1/2" X 6"
BEARING PLATE
ROOF JOIST RE: PLAN
WITH SIMPSON LUS
HANGER
LVL BEAM RE: PLAN
3" MAX GRAVEL BALLAST
WATERPROOFING AND
DRAINBOARD RE: ARCH.
SECTION 6
3/4" = 1'-0"
RE: PLAN
TOP OF
CONCRETE
FINISH FLOOR RE: ARCH.
SLAB-ON-GRADE RE: PLAN
#5 AT 2'-0" X 2'-0"2'-0"
FOUNDATION WALL
RE: 1/S3.2
DECK JOIST
RE: PLAN
TREATED 2X10 LEDGER
WITH 5/8" Ø EPOXY ANCHORS
WITH 5" EMBEDMENT AT 2'-8"
STAGGER TOP AND BOTTOM
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
SECTION 7
1 1/2" = 1'-0"
SECTION 8
1 1/2" = 1'-0"
HSS COLUMN RE: PLAN
1/2" X 6" X 1'-0"
(2)-3/4" Ø BOLTS
STEEL BEAM RE: PLAN WITH 2X
TOP PLATE
3/8" STIFFENER ALIGN WITH
COLUMN ABOVE
HSS COLUMN RE: PLAN
1/4 6"
1/2" X 6" X 8" CAP PLATE WITH
(2)-3/4" Ø BOLTS
SHEAR WALL RE: PLAN
HOLD-DOWN RE: SCHEDULE
WITH 5/8" Ø THRU-BOLT
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0"
STAGGER
STEEL BEAM RE: PLAN
SECTION 9
3/4" = 1'-0"
HSS COLUMN RE: PLAN
FOUNDATION WALL
RE: 7/S3.1
1/2" BASE PLATE WITH (4)-1/2" Ø
THREADED STUDS WELDED TO
EMBED PLATE
5/8" X 6" X 1'-6" EMBED PLATE
WITH (6)-#5 X 2'-0"
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FLOOR FRAMING
SECTIONS
S4.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
2
12
2
12
2
12
2
12
EQUAL
(UNLESS NOTED ON PLAN) EQUAL
RE: ARCH.
8" 6"2"4" 4" A
A
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
LVL RE: PLAN
SIMPSON H3
EXTERIOR WALL WITH SHEATHING
SUB-FASCIA
RE: PLAN WITH (4)-10d NAILS
SOLID BLOCKING BETWEEN
JOISTS
SOLID BLOCKING BETWEEN
JOISTS
ROOF JOIST RE: PLAN
(2)-SDS25350 SCREWS
STEEL BEAM RE: PLAN WITH
(2)-2X6 BEVELED TOP PLATE
WITH 1/2" Ø THRU-BOLTS AT
2'-0"
ROOF SHEATHING
ROOF SHEATHING
SUB-FASCIA RE: PLAN
ROOF JOIST RE: PLAN
(2)-SDS25500 SCREWS
LSTA15 AT 4'-0"
LVL BEAM RE: PLAN
ROOF SHEATHING
SOLID WEB PACK WITH
1/2" Ø THRU-BOLTS AT
1'-4" STAGGER
STEEL BEAM RE: PLAN
WITH BEVELED TOP PLATE
WITH 1/2" Ø THRU-BOLTS
AT 2'-0"
ROOF JOIST RE: PLAN
WITH SIMPSON LSSU
HANGER
WEB BLOCKING AS REQUIRED
RE: MANUFACTURER
SECTION 4
3/4" = 1'-0"
ROOF SHEATHING
ROOF JOIST RE: PLAN
SOLID BLOCKING BETWEEN
JOISTS
EXTERIOR WALL WITH
SHEATHING(2)-SDS25500 SCREWS
EXTERIOR WALL WITH SHEATHING FLASHING AND WATERPROOFING
RE: ARCH.
ROOF SHEATHING
ROOF FRAMING RE: PLAN
STEEL BEAM RE: PLAN WITH
SOLID WEB PACK BLOCKING
WITH 1/2" Ø THRU-BOLTS
AT 1'-4" STAGGER AND 2X TOP
PLATE WITH 1/2" Ø THRU-BOLTS
AT 1'-4"
EXTERIOR WALL WITH SHEATHING FLASHING AND WATERPROOFING
RE: ARCH.
ROOF SHEATHING
ROOF FRAMING RE: PLAN
WITH SIMPSON IUS HANGER
AND WEB BLOCKING AS
REQUIRED
CONTINUOUS SHEATHING
ACROSS ROOF/PARAPET
(NO HORIZONTAL SEAMS)
LVL BEAM RE: PLAN
WINDOW RE:ARCH.ROOF JOIST RE: PLAN
WITH SIMPSON ITS HANGER
WATERPROOFING
AND DRAINAGE
RE: ARCH.
SIMPSON LSTA21
AT 2'-8"
3" MAX. GRAVEL
BALLAST
CJP
3/8" X 4" X 1'-2 1/2"
SHEAR PLATE WITH
(5)-3/4" Ø BOLTS
STEEL BEAM
RE: PLAN
CJP
1/4" 2" AT 4"
HSS BEAM RE: PLAN
HSS COLUMN RE: PLAN
CJP
BOTH
SIDES
CJP
SECTION A-A
SECTION 13
3/4" = 1'-0"
SECTION 12
3/4" = 1'-0"
SECTION 11
3/4" = 1'-0"
SECTION 10
3/4" = 1'-0"
STEEL BEAM RE: PLAN
3/8" X 4" X 11 1/2" SHEAR
PLATE WITH (4)-3/4" Ø BOLTS
HSS COLUMN RE: PLAN
3/16
CJP TOP AND
BOTTOM FLANGES
HSS COLUMN RE: PLAN
3/8" X 4" X 11 1/2" SHEAR
PLATE WITH (4)-3/4" Ø BOLTSSTEEL BEAM
RE: PLAN
1/2" X 6" X 6" MOMENT
PLATE TOP AND BOTTOM
1/4 6"
TOP AND BOTTOM
FLANGE
CJP TOP
AND BOTTOM
ROOF JOIST RE: PLAN
SOLID BLOCKING BETWEEN
JOISTS
EXTERIOR STUD WALL
WITH SHEATHING
WEB BLOCKING AS
REQUIRED
SIMPSON H3
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. GRAVEL
BALLAST
ROOF SHEATHING
1/4" X 3" X 10" PLATE WITH
(2)-1/2" Ø THRU-BOLTS
LVL BEAM RE: PLAN
HSS COLUMN RE: PLAN
1/4
.
.
.
.
.
.
.
.
.
. .
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
ROOF FRAMING
SECTIONS
S5.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
MARCIN ENGINEERING LLCVICINITY MAP
PROPOSED PROJECT
LOCATION
APPROXIMATE SCALE: 1"=1,000'
TABLE OF CONTENTS
C001 COVER SHEET AND NOTES
C002 DRIVEWAY GRADING PLAN
C003 EXCAVATION PLAN
C004 EROSION CONTROL PLAN
C005 CONSTRUCTION DETAILS
LOT 12
LOT 10B
10/8/20
01/22/21
0+00
1+002+0 0
2+01
8130
8128.00
8133.59
8133.78
8131.98
8128.64
8124.61
8119.56
8119.56
8125.79
2:1
3:1
2.5 :1
2.5:12.5:13:12.5:1812081308
1
4
0
815081608170818081908
2
0
081228124812681288132813481
3
6
8
1
38 81428
1
4
4 814681488152815481568158816281648
1
6
6 816881728
1
7
4
8
1
7
6 817881828184818681888
1
9
2
81
94
8
1
9
6
8
1
9
8
82
02 820482068
1
9
0
8
1
8
2
8
1
8
4 818681888
1
9
2
81608170
81
8
0
8162816481668168
8172
817
4
817
6
8
1
7
8
81308
1
4
0 815081608170812481268128813281348
1
3
6
8
1
3
8 8142814481468148815281548156815881628164816681688172817481768110
8
1
0
6
8108
8
1
1
2
8114
81
1
6
2:12.5:1
2.5:1
8122
8124
812
6
8128
813281348120
813081408150812081108120 81408
1
5
0
8
1
6
02.5:13 :14:12.5:13 :1
2.5:12.5:181608129.00
8135.00
3:18120.00
8116.00 2.5:12.5:12:18130
3:1
BW: 8177.00
TW: 8169.00
8163.00
BW: 8170.00
8169.00 8177.00
BW: 8156.00
TW: 8162.00
8163.00
TW: 8182.00
8177.00
TW: 8162.00
BW: 8160.00
TW: 8176.00
TW: 8183.00
8183.00
8170.008164.00
TW: 8169.00
BW: 8163.00
8170.00
8120.00
8122.00
BW: 8124.33
TW: 8128.00
BW: 8127.40
BW: 8124.00
TW: 8129.28
TW: 8154.00
BW: 8150.00
BW: 8144.00
TW: 8148.00
TW: 8126.00
BW: 8120.00
BW: 8117.00
TW: 8122.00
TW: 8130.00
BW: 8124.00
TW: 8132.00
TW: 8124.00
BW: 8120.00
TW: 8120.00BW: 8114.00
TW: 8124.00
BW: 8118.00
TW: 8112.00
BW: 8108.00
TW: 8114.00
BW: 8110.00
TW: 8122.00
BW: 8116.00
8140.00
8144.00
8144.00
8147.90
BW: 8126.00
BW: 8156.00
TW: 8162.00
TW: 8162.00
BW: 8156.00
TW: 8169.00
BW: 8163.00
BW: 8158.00
TW: 8162.00
TW: 8176.00
BW: 8170.00
TW: 8131.20
8147.34
TW: 8128.00BW: 8122.00
TW: 8118.00
BW: 8112.00
8132.00
8134.00
8138.00 81408178.00
BW: 8163.00
BW: 8170.08
2 .5:12.5:1TW: 8176.00
2.5:12.5:1
2.5:1
TW: 8142.00
BW: 8136.00
BW: 8150.00
TW: 8155.77
2:1
TW: 8177.00
8176.00
8127.60
BW: 8136.50
TW: 8140.00 MARCIN ENGINEERING LLCGRAPHIC SCALE
(IN FEET)
1 inch = 10 ft.
12/04/20
01/22/21
8170818 0
8190
82 00
816 4
8166816 8
81728174817681788182
8184818681888 1 9 2
8 1 9 4
8196
81988202820481108120813
0
81408150
8160
8170
8 1 06
8108811281148116811881228124812681288132
8134
8136
8 1 3 8
8142814481 46
8148
8 152
8154
81 56
8 1 5 8
816 2
816 4
816681 68
817217481408 150
81608134813681388142814481468148
8 15 2
81 54
81 56
815 8
8 1 6 2
8130812881328 12 68128
8150
8144
8146
8148
8
1
3
0
8
1
4
0
8
1
3
2
8
1
3
4
8
1
3
6
8
1
3
8
8
1
4
2
8130
8 1 3 2
8134
813 0
TW-FG: 8162.00
TW-FG: 8162.00
TW: 8160.00
TW: 8160.00
TW: 8157.27
BW: 8147.83
BW: 8148.08
BW: 8148.08
BW: 8148.08
BW: 8148.08
TW: 8143.83
BW: 8135.83
BW: 8135.83
TW: 8143.83
TW: 8148.08
BW: 8133.83
TW: 8148.08
BW: 8133.83
TW: 8144.33
BW: 8140.33
TW: 8143.83
BW: 8139.83
8147.83
BW: 8130.50
BW-FG: 8136.00
TW: 8142.00
8139.00
TW: 8158.71
TW: 8146.52
BW: 8133.00
BW: 8133.00 TW: 8162.41
813 2
8 134
81 36
8 138
81708180MARCIN ENGINEERING LLCGRAPHIC SCALE
(IN FEET)
1 inch = 10 ft.
12/04/20
01/22/21
8
1
3
0
8132
8
1
2
8
81248122
8 13 4 816081708160814081208150818081708170816081308110MARCIN ENGINEERING LLCGRAPHIC SCALE
(IN FEET)
1 inch = 10 ft.
UNIT A
UNIT B
10/8/20
01/22/21
RECP Apron
RECP Apron
Backfill
Sediment
Control
Log
Drain
Grate
6'
3'
3
1
3
1
6" CDOT
CLASS 6 ROAD BASE
3 1
2" ASPHALT
FILL AREA
CUT AREA
4.0%2.0%2.0%4.0%
4.5'4.5'
1
2
4" TOP SOILGRAVEL SHOULDER3
1
6'
1'GRAVEL SHOULDER1.5'
NATIVE COMPACTED SOIL
ASSUMED TO BE LEADVILLE
SANDY LOAM.
TO BE VERIFIED PRIOR TO
CONSTRUCTION
NOTE: DESIGN TO BE VERIFIED BY
GEOTECHNICAL ENGINEER'S REPORT
PRIOR TO CONSTRUCTION.MARCIN ENGINEERING LLC12/04/20
01/22/21
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
GENERAL NOTES,
LEGEND AND
SCHEDULES
EL0.1
LEGEND
A SURFACE MOUNTED DECORATIVE FIXTURE
B WALL MOUNTED DECORATIVE FIXTURE
RECESSED FIXTURE
IN-GRADE WELL LIGHT
SURFACE MOUNTED FLUORESCENT FIXTURE
FLUORESCENT CLOSET STRIP WITH SIZE
RECESSED STEP LIGHT
LINEAR LOW VOLTAGE STRIP
ROPE LIGHT (LOW OR LINE VOLTAGE)
TRACK WITH HEADS
ILL. FIBER OPTICS ILLUMINATOR
FIBER OPTICS FIXTURE LENS
JB
FP
S SWITCH
S 3 3-WAY SWITCH
S 4 4-WAY SWITCH
S D DIMMER SWITCH
S DS DOOR SWITCH
S D3 3-WAY DIMMER SWITCH
##LIGHTING CONTROL KEYPAD (WITH TWO-DIGIT ADDRESS)
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
GFI DUPLEX RECEPTACLE WITH GROUND FAULT
DUPLEX RECEPTACLE (WEATHER PROOF)WP
GFI
GD GARAGE DOOR OPENER RECEPTACLE
HALF-SWITCHED DUPLEX RECEPTACLE
FULLY-SWITCHED DUPLEX RECEPTACLE
SWITCHED SIMPLEX RECEPTACLE
FLOOR RECEPTACLE (SEE INSTALLATION NOTES FOR SPEC)
HALF-SWITCHED FLOOR RECEPTACLE (SEE INSTALLATION NOTES)
FULLY-SWITCHED FLOOR RECEPTACLE (SEE INSTALLATION NOTES)
CLOCK RECEPTACLE
EXHAUST FAN
LIGHTING CONTROL LOAD NUMBER
DRAPERY MOTOR
DISPOSAL
MOTION SENSOR (MOUNT ON WALL UNLESS NOTED OTHERWISE)MS
TELEPHONE OUTLET
NETWORK PORT
TELEVISION OUTLETTV
CEILING SPEAKER
WALL SPEAKER
SMOKE & CARBON MONOXIDE DETECTORSD
#XXX
XX
XX
(REFER TO DECORATIVE LIGHTING FIXTURE SCHEDULE)
(REFER TO DECORATIVE LIGHTING FIXTURE SCHEDULE)
OTHER WALL MOUNTED FIXTURE
OTHER SURFACE MOUNTED FIXTURE
48"
RECESSED FIXTURE WITH LAMP AND LENS SPECIFICATIONEXT
CLEAR
JUNCTION BOX
FIREPLACE IGNITION
LIGHTING FIXTURE SCHEDULE
ASPEN FALLS WHITE LIGHTING DESIGN
1469 GREENHILL COURT, VAIL CO 81657 2328 S. ORCHARD WAY
19-XXX LAKEWOOD, CO 80228
MARK DESCRIPTION MANUFACTURER CATALOGUE NUMBER LAMP NOTES VOLT.
A CEILING MOUNTED FIXTURE SEE DECORATIVE SCHEDULE
B WALL MOUNTED FIXTURE SEE DECORATIVE SCHEDULE
C1 RECESSED ACCENTS - S / ROUND PINHOLE / FLANGED / I.C. JUNO ACULUX # AX3A - 12LM - 27K - 90CRI - 12D - FPC - 120 - ICAT / 3DPIN-BS-WHSF 17 WATT INTEGRAL LED
C2 RECESSED ACCENTS - N / ROUND PINHOLE / FLANGED / I.C. JUNO ACULUX # AX3A - 12LM - 27K - 90CRI - 24D - FPC - 120 - ICAT / 3DPIN-BS-WHSF 17 WATT INTEGRAL LED
C3 RECESSED ACCENTS - F / ROUND PINHOLE / FLANGED / I.C. JUNO ACULUX # AX3A - 12LM - 27K - 90CRI - 36D - FPC - 120 - ICAT / 3DPIN-BS-WHSF 17 WATT INTEGRAL LED
C4 RECESSED WALL WASH / ROUND PINHOLE / FLANGED / I.C. JUNO ACULUX
C5 NOT USED
D1 NOT USED
D2 NOT USED
D4 NOT USED
E1 RECESSED DOWNLIGHTS / ROUND HYPERBOLE / FLANGED / I.C. JUNO # IC20LEDG4 - 14L - 27K - 90CRI - 120 - FRPC / 204HYP3 - HZ - WH 17 WATT INTEGRAL LED
E2 RECESSED LENSED DOWNLIGHTS JUNO # IC20LEDG4 - 14L - 27K - 90CRI - 120 - FRPC / 210N-WH
J1 LINEAR UNDER-CABINET LED OMNILIGHT 'GENISIS' # GEN - 27 - SHO - 16 / OCH - SCS - 2M - FR 5.3 W/FT. REMOTE POWER SUPPLY
J3 LINEAR LED IN CLOSET OMNILIGHT 'GENISIS' # GEN - 27 - HO - 16 / OCH - SCS - 2M - FR 3.5 W/FT. REMOTE POWER SUPPLY
K CLOSET FIXTURE ( SEE FIXTURE ON PLAN FOR SPECIFIC LENGTH ) GM LIGHTING # SLCB - XX - 30 - WH VARIES
L2 LINEAR LED / COVE LIGHTING OMNILIGHT 'GENISIS' # GEN - 27 - UHO - 16 / OCH - SCS - 2M - FR 6.6 W/FT. REMOTE POWER SUPPLY
L4 LINEAR LED / WET LOCATION OMNILIGHT 'GENISIS' # GENWL - 27 - HO - 16 3.5 W/FT. REMOTE POWER SUPPLY
M RECESSED SHOWER JUNO # IC44N / 441 - WWH 7 WATT SORRA LED-MR16
P EXTERIOR HEATER INFRA TECH # SL - 3024 3000 WATTS - 240 VOLTS
Q MINI ACCENTS IN CABINET JUNO # MDL1G2 - 27K - NFL - WH 5 WATT INTEGRAL LED REMOTE POWER SUPPLY
U1 GARAGE SURFACE MOUNTS CREE # LS4 - 40L - 35K - 10V 44 WATT INTEGRAL LED
U2 STORAGE SURFACE MOUNTS CREE # LS4 - 25L - 35K - 10V 23 WATT INTEGRAL LED
R1 LINEAR LED LIGHTING / VERTICAL CABINETRY OMNILIGHT 'GENISIS' # GEN - 27 - HO - 16 3.5 W/FT. REMOTE POWER SUPPLY
R2 LINEAR TOE-KICK / LED LIGHT OMNILIGHT 'GENISIS' # GEN - 27 - SO - 16 1.8 W/FT. REMOTE POWER SUPPLY
S STEP LIGHT WAC # WL - LED100 - C - BZ 3.9 WALL LED
T SECURITY LIGHTING T.B.D.
V RECESSED LINEAR LED NULITE "REGOLO 2" # RF2 - 09 - L30 - 120 - D3 - 1C - FR - WH - 4' 7.8 W/FT. 0-10 VOLT DIMMING
W WELL LIGHT VISION III # IG2A - BN - STD - PC - 0 - 0 - 0 - H1 7 WATT SORRA LED-MR16 REMOTE TRANSFORMER
Z EXTERIOR MONOPOINT B-K LIGHTING "DELTA STAR" # DS-MR - 0 - BZP - 9 - 11 - A / # BC7 - BZP 7 WATT SORRA LED-MR16 REMOTE TRANSFORMER
DECORATIVE FIXTURE SCHEDULE
ASPEN FALLS WHITE LIGHTING DESIGN
1469 GREENHILL COURT, VAIL CO 81657 2328 S. ORCHARD WAY
19-XXX LAKEWOOD, CO 80228
MARK QTY. DESCRIPTION MANUFACTURER CATALOGUE NUMBER LAMP NOTES VOLT.
A1 1 HER BATH
A2 UTILITY CEILING MOUNTS
A3 3 WINE ROOM PENDANTS
A4 - NOT USED
A5 1 MEDIA VESTIBULE PENDANT
A6 4 HALLWAY AND VESTIBULE PENDANTS
A7 2 DINING TABLE CHANDELIERS
A8 1 PACKAGE STORAGE CEILING MOUNT
A9 1 LIVING ROOM CHANDELIER
A10 3 HIS STUDY CHANDELIERS
A11 2 FAMILY ROOM CHANDELIERS
A12 1 BREAKFAST ROOM CHANDELIER
A13 3 KITCHEN ISLAND PENDANTS
A14 4 ELEVATOR HALL PENDANTS
A15 1 MOLLY'S OFFICE PENDANT
A16 1 PANTRY PENDANT
A17 3 HER CLOSET CEILING MOUNT
A18 1 UPPER HALL PENDANT
A19 - NOT USED
A20 1 STAIRCASE PENDANT
A21 1 MAIN STAIR CHANDELIER
A22 1 MASTER VESTIBULE PENDANT
A23 1 GUEST BATH VESTIBULE PENDANT
A24 1 MASTER BEDROOM PENDANT
A25 3 GAS LANTERNS ON ENTRY PORCH
A26 3 MUD HALL PENDANTS
A27 1 HIS CLOSET PENDANT
B1 2 BASEMENT BATH SCONCES
B2 2 BASEMENT LIVING SCONCES
B3 6 MEDIA SCONCES
B4 2 POWDER ROOM 3 SCONCES
B5 2 DINING ROOM SCONCES
B6 2 POWDER ROOM 2 SCONCES
B7 2 POWDER ROOM 1 SCONCES
B8 EXTERIOR WALL SCONCES
B9 2 LOWER GALLERY WALL SCONCES
B10 2 BATH 4 SCONCES
B11 2 HIS VANITY SCONCES
B12 2 HER VANITY SCONCES
B13 2 BATH 1 SCONCES
B14 2 BATH 2 SCONCES
B15 2 LIVING ROOM SCONCES
B16 4 GUEST BATH SCONCES
B17 2 BATH 3 SCONCES
B18 6 HIS STUDY WALL SCONCES
B19 2 HER CLOSET DRESSING MIRROR
B20 2 GAS LANTERNS AT GATE
CONFLICTS OR SUBSTITUTIONS:
· ELECTRICAL AND GENERAL CONTRACTORS ARE TO CONTACT WHITE LIGHTING DESIGN IF ANY
CONFLICTS ARISE OUT OF FIXTURES SPECIFIED AND THEIR AVAILABILITY.
· NO SUBSTITUTION FOR SPECIFIED FIXTURES IS PERMITTED WITHOUT PRIOR APPROVAL FROM WHITE
LIGHTING DESIGN.
LAMPING:
· CONTRACTOR SHALL INSTALL HONEYCOMB LOUVRES, CLEAR LENSES OR SPREAD LENSES WHERE
SPECIFIED. IF NO INDICATION IS MADE, THE LENS PROVIDED BY THE MANUFACTURER SHALL BE
LEFT IN PLACE.
ELECTRICAL:
· ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ELECTRICAL NEEDS FOR ALL APPLIANCES.
· ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL NATIONAL AND LOCAL ELECTRICAL CODES
ARE FOLLOWED, INCLUDING BUT NOT LIMITED TO CONVENIENCE OUTLET PLACEMENT AND WIRE
TERMINATIONS.
· CONTRACTOR TO RUN SEPARATE CONDUIT FOR TELEPHONE, LOW VOLTAGE LIGHTING
CONTROL, OR A/V CONTROL WIRE WHERE INDICATED. MAINTAIN AT LEAST 12" SEPARATION
BETWEEN ANY PARALLEL RUNS OF LINE AND LOW VOLTAGE WIRE.
OUTLETS:
· WALL OUTLETS IN PRIMARY ROOMS SHALL BE HORIZONTAL IN BASEBOARDS, DECORA STYLE. [[
VERIFIED.]]
WALL OUTLETS IN SECONDARY ROOMS SHALL BE VERTICAL, 16" A.F.F. TO TOP OF BOX, DECORA
STYLE. [[VERIFIED.]]
· BATHROOM GFI OUTLETS SHALL BE HORIZONTAL IN THE BACKSPLASH. [[NOT VERIFIED.]]
· KITCHEN OUTLETS TO BE VERTICAL IN THE BACKSPLASH. [[NOT VERIFIED.]]
· CONTRACTOR TO VERIFY ALL POWER REQUIREMENTS WITH OWNER PRIOR TO ROUGH-IN.
· CONTRACTOR TO VERIFY COLOR OF ALL WALL AND FLOOR BOX DEVICES WITH OWNER PRIOR
TO ROUGH-IN.
· CONTRACTOR TO VERIFY EXACT LOCATION AND STYLE OF FLOOR PLUGS WITH OWNER PRIOR
TO ROUGH-IN.
· USE STEEL CITY #664/664-CST-BRN WHERE FLOOR BOXES ARE TO BE INSTALLED UNDER FURNITURE
OR WHERE A FLOOR MOUNTED TELEPHONE JACK IS REQUIRED. USE LEW #RCFB-1 WHERE
FLOOR BOXES ARE VISIBLE SUCH AS PERIMETER WALLS.
LIGHTING CONTROLS:
· LIGHTING CONTROL SYSTEM SHALL BE A LUTRON HOMEWORKS SYSTEM, WITH SEETOUCH
DESIGNER PLATES WITH MATTE FINISH. ELECTRICAL CONTRACTOR SHALL FOLLOW ALL
MANUFACTURER GUIDELINES AND SPECIFICATIONS WITHOUT EXCEPTION.
· CONTROL DEVICES TO BE INSTALLED 48" A.F.F. TO BOTTOM OF BOX, UNLESS OTHERWISE NOTED.
[[NOT VERIFIED.]]
· LIGHTING CONTROL DEVICES AT BEDSIDES TO BE INSTALLED 34" A.F.F. TO BOTTOM OF BOX.
[[NOT VERIFIED.]]
· MOTION SENSORS SHALL BE WALL MOUNTED WHERE POSSIBLE, USE WATT STOPPER #RS-150U.
DECORATIVE "A/B" FIXTURES:
· VERIFY MOUNTING HEIGHTS OF WALL SCONCES WITH OWNER PRIOR TO ROUGH-IN. LEAVE 24"
WHIP TO ALL WALL MOUNTED FIXTURES.
· USE MAXIMUM ALLOWABLE WATTAGE IN ALL DECORATIVE FIXTURES.
INSTALLATION NOTES
CONSTRUCTION ADMINISTRATION:
· ELECTRICAL CONTRACTOR SHALL HAVE ALL BOX LOCATIONS APPROVED BY WLD AND OWNER
IN A ROUGH-IN WALK THROUGH PRIOR TO RUNNING WIRE.
LIGHTING CONTROL SYSTEM:
· IN THE EVENT THAT A TOTAL OR PARTIAL LIGHTING CONTROL SYSTEM IS SPECIFIED, THE
ELECTRICAL CONTRACTOR (IN CONJUNCTION WITH CONTROLS DEALER, IF NOT THE
CONTRACTOR) SHALL BE RESPONSIBLE FOR SCHEDULING THE "START UP" OF THE LIGHTING
CONTROL SYSTEM, INCLUDING BUT NOT LIMITED TO:
· CONFIRMING THAT ALL EQUIPMENT IS AS SPECIFIED AND LOCATED/ADDRESSED CORRECTLY, AS
PER PANEL SCHEDULES
·VERIFYING ALL WIRING TERMINATIONS AND LOW VOLTAGE COMMUNICATION
·CHECKING FOR SHORTS
·VERIFYING THAT EACH LOAD IS LANDED AS SPECIFIED PER PANEL SCHEDULES AND IS
FUNCTIONING PROPERLY
· VERIFYING THAT EACH KEYPAD AND/OR DIMMER IS COMMUNICATING AND FUNCTIONING
PROPERLY
· WHITE LIGHTING DESIGN SHALL SPECIFY, DESIGN AND PROGRAM THE LIGHTING CONTROL
SYSTEM BUT SHALL NOT PROVIDE ANY EQUIPMENT OR WARRANTY FOR THE SYSTEM.
· IT IS NOT CONSIDERED TO BE IN WHITE LIGHTING DESIGN'S SCOPE OF WORK TO TROUBLESHOOT,
ISOLATE, OR OTHERWISE DIAGNOSE WIRING OR EQUIPMENT PROBLEMS.
TRIM-OUT AND MOVE-IN PHASE:
· WLD WILL SUPPLY A SET OF DRAWINGS THAT WILL DETAIL ALL MR16 LAMPING AND LENSING
INFORMATION TO BE INSTALLED BY ELECTRICAL CONTRACTOR AT THE TIME OF TRIM-OUT.
TEMPORARY LAMPING MAY BE INSTALLED UNTIL THAT TIME.
· WLD WILL REQUEST ASSISTANCE FROM ELECTRICAL CONTRACTOR DURING FINAL AIMING. THIS
WILL INCLUDE TIME FROM 2-3 ELECTRICIANS AS WELL AS THE USE OF LADDERS TO REACH ALL
ADJUSTABLE ACCENT FIXTURES. THIS MAY BE DIVIDED INTO SEPARATE VISITS DEPENDING ON
OWNER'S MOVE-IN SCHEDULE.
BID NOTES
01/22/21
B
UP
DN
Mech
Coat
ENTRY
Mud/Storage
1 2 4 3
A
C
D
B
B C C
E
E
E
E
E
E E
S
S
S
MS
A
KEYLESS
WP
GFI
3
3
GARAGE
OPENER
4
3
S
U
U
U
U
TO SWITCH ABOVE
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
ENTRY EAST LIGHTING PLAN1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
ENTRY EAST
LIGHTING PLAN
EL1.0
SEE SHEET EL1.3 FOR CONTINUATION
01/22/21
DN
Family
OFF/BR #2
Bath #2
Laund
y
Bath #3
CL 3
BR #4
Bath 4
Deck
Bar
Bed #3
UP
Elev
1 2 43
A
C
D
E
F
B
H
I
CC
B
B
GFI
GFI
3
3
GFI 3
C C
CC
43 4
EE
E
E
4
3
3
SS
TO STEP LIGHTS
3 3
TO STEP LIGHTS
BELOW
E
B B
GFI
A
C
C
3
3
DS
GFI
B
K
K
DS
CC
E
E
3
3
B B
GFI
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
GUEST EAST LIGHTING PLAN1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
GUEST EAST
LIGHTING PLAN
EL1.1
SEE SHEET EL1.4 FOR CONTINUATION
01/22/21
Kitchen
M Bth
Dine
Pow
Master
M Closet
Living
Patio
Eating bar
Dining
FP
Elev
UP
DN
1
1
2
2
4
4
3
3
A
C
D
E
F
B
H
I
Bar
offset vents
from below
C
C
C
E
E
M
M
E
B
B
GFI
GFI
E
E
E
3
A
C
C
3
3
SS
SS
3
A
C
C
C
GFI
A
A
E E
E
E
S
S
S
S
BELOW LIGHTS
ABOVE
MS A
B
B
GFI
WP
3
B GFI
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
LIVING EAST LIGHTING PLAN1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
LIVING EAST
LIGHTING PLAN
EL1.2
SEE SHEET EL1.5 FOR CONTINUATION
01/22/21
DN
Covered Entry
Entry
Garage
CL
Mud
Mech
5 6
H
I I
J J
M
K
L
Q Q
UP 4 6" RISERS
BB
CC
E
E
E
E
E E
S
MS
A
KEYLESS
WP
GFI
3
GARAGE
OPENER
4
3
S
DS
K
S
S
3
U
U
U
U
TO SWITCH ABOVE
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
ENTRY WEST LIGHTING PLAN1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
ENTRY WEST
LIGHTING PLAN
EL1.3
SEE SHEET EL1.0 FOR CONTINUATION
01/22/21
Family
Laundry
Linen
Pow
Bath 2
Bed 2
CL 2 His
Bed #3
Bath 3
CL 3 Hers
Bed #4
CL 4
Bath 4
Deck
Deck
Elev
UP
DN
Bar
5 6 8 9 7
H
I
J
M
N
O
P
K
L
Q
CL 2
CC
3
EE
B
GFI
WP
GFI
A
MS
A
3
MS
A
B
GFI
MS
E
E
GFI
C
C C
3
A
3
3
E E
3
4
3
E
E
E
E
C
C
3
DS
K
3
B
3
WP
GFI
C
C
3
E
E
MS
A M
B
GFI
E
E
E
3 3
3
S S
S
TO LIGHTS ABOVE
TO LIGHTS BELOW
3
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
GUEST WEST LIGHTING PLAN1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
GUEST WEST
LIGHTING PLAN
EL1.4
SEE SHEET EL1.1 FOR CONTINUATION
01/22/21
Dining
Kitchen
Pantry
Lib
His
CL
Master
Master Bath
FP
Patio
Elev
UP
DN
Living
4
5
5
6
6
8
8
9
97
H
I
J J
M
N
O
P
K
L
Q Q
FP
TV
TV
C
C
C C
A
GFI
GFI
E E E
E
E
A
3
C
E
E
3
S
S
TO LIGHTS BELOW
3
B BB
GFI
WP
GFI
3
B
GFI
MS
A
E
M
B BGFI GFI
DS
K
DS
E
E
E
3
MS
A
MS
A
3
C
C
3
E
E
E
33
TO LIGHTS ABOVE
SCALE: 1/4" = 1'-0"
1' 2' 4' 8' 16' 0
LIVING WEST LIGHTING PLAN 1
N
KEYNOTES
NOTES
4
3
2
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job #1469 Greenhill Crt9/1/2019Lot 11 Glen Lyon Subdivision ColoradoLot 11 Glen Lyon SubdivisionProject Status
Building Permit
Revisions
WHITE LIGHTING DESIGN
2328 South Orchard Way
Lakewood, Colorado 80228
303-463-6661 phone
www.whitelightingdesign.com
LIVING WEST
LIGHTING PLAN
EL1.5
SEE SHEET EL1.2 FOR CONTINUATION
01/22/21
01/22/21
01/22/21
GENERAL NOTES
1. LIVE LOADS USED IN DESIGN:
A. ROOF PITCH 4:12 OR STEEPER 80 PSF
B. ROOF PITCH LESS THAN 4:12 100 PSF
C. TYPICAL FLOOR 40 PSF
D. EXTERIOR DECK 100 PSF
E. RISK CATEGORY II
SEISMIC FACTOR IE 1.0
SNOW FACTOR IS 1.0
F. WIND
WIND SPEED, Vult 115 MPH (ULTIMATE)
WIND SPEED, Vasd 89 MPH (ASD)
EXPOSURE B
INTERNAL PRESSURE COEFFICIENT (GCpi) +/- 0.18
G. LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.
H. CODE USED IN DESIGN: INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION.
2. DEFERRED SUBMITTAL
A. DEFERRED SUBMITTALS PER SECTION 107.3.4.1 SHALL BE SUBMITTED TO THE BUILDING
OFFICIAL AND THE DESIGN PROFESSIONALS AND REVIEWED PRIOR TO INSTALLATION.
B. DEFERRED SUBMITTALS ARE:
1. STRUCTURAL STEEL SHOP DRAWINGS.
C. ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE
LICENSED PROFESSIONAL ENGINEER RESPONSIBLE FOR THE PREPARATION OF THESE
DOCUMENTS.
3. TESTING, INSPECTIONS AND OBSERVATIONS:
A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.
STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THE
CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIRED
INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIAL
INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL
BUILDING CODE.
B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESS
SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.
1. SOIL PREPARATION
a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILL
AND IN-PLACE DRY DENSITY OF THE COMPACTED FILL FOR
CONFORMANCE WITH THE APPROVED REPORT.
2. CONCRETE CONSTRUCTION
a. PERIODIC INSPECTION OF REINFORCING STEEL AND PLACEMENT.
b. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.
c. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED
TO FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND
AIR CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE
CONCRETE.
d. CONTINUOUS INSPECTION OF CONCRETE PLACEMENT FOR PROPER
APPLICATION TECHNIQUES.
e. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING
TEMPERATURE AND TECHNIQUES.
3. STEEL CONSTRUCTION - COMPLY WITH AISC 360, CHAPTER N.
a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTION
EXCEPT THE FOLLOWING:
1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN
ACCORDANCE WITH AISC 360, CHAPTER N.
b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENT
DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,
WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS ARE
VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS ARE
MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDS
IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOP
WELDING.
1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.
2. WELDING OF STAIRS AND RAILING SYSTEMS.
c. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS
AND MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.
d. PERIODIC INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE
WITH THE DETAILS SHOWN ON THE APPROVED CONSTRUCTION
DOCUMENTS SUCH AS BRACING, STIFFENING, MEMBER LOCATIONS AND
PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION.
e. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDS
SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS AND
MANUFACTURER'S CERTIFIED MILL TEST REPORTS.
f. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS
FOR CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVED
CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OF
COMPLIANCE.
g. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGH
STRENGTH BOLTS.
1. WHILE THE WORK IS IN PROGRESS, THE SPECIAL INSPECTOR
SHALL DETERMINE THAT THE REQUIREMENTS FOR BOLTS, NUTS,
WASHERS AND PAINT, BOLTED PARTS AND INSTALLATION AND
TIGHTENING IN SUCH STANDARDS ARE MET. FOR BOLTS
REQUIRING PRETENSIONING, THE SPECIAL INSPECTOR SHALL
OBSERVE THE PREINSTALLATION TESTING AND CALIBRATION
PROCEDURES WHEN SUCH PROCEDURES ARE REQUIRED BY THE
INSTALLATION METHOD OR BY PROJECT PLANS OR
SPECIFICATIONS; DETERMINE THAT ALL PLIES OF CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED AND MONITOR THE INSTALLATION OF BOLTS TO VERIFY
THAT THE SELECTED PROCEDURE FOR INSTALLATION IS
PROPERLY USED TO TIGHTEN BOLTS. FOR JOINTS REQUIRED TO
BE TIGHTENED ONLY TO THE SNUG-TIGHT CONDITION, THE
SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTED
MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY
SNUGGED.
2. MONITORING OF BOLT INSTALLATION FOR PRETENSIONING IS
PERMITTED TO BE PERFORMED ON A PERIODIC BASIS WHEN
USING THE TURN-OF-NUT METHOD WITH MATCHMARKING
TECHNIQUES, THE DIRECT TENSION INDICATOR METHOD OR THE
ALTERNATE DESIGN FASTENER (TWIST-OFF BOLT) METHOD.
JOINTS DESIGNATED AS SNUG TIGHT NEED TO BE INSPECTED
ONLY ON A PERIODIC BASIS.
4. FOUNDATIONS
A. MAXIMUM SOIL DESIGN PRESSURE 2000 PSF
B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT NO. 19-7-170
BY KUMAR & ASSOCIATES DATED JULY 12, 2019.
C. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARING
ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BY
CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGS
SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.
D. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL OR
PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILL
SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ASTM
D1557 UNLESS OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS ARE
ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOIL
REPORT FOR DESCRIPTION OF BEARING SOIL).
E. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12
INCH MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFER
TO SOILS REPORT FOR BACKFILL MATERIAL.
F. NO BACKFILLING SHALL BE PLACED AGAINST LOWER LEVEL WALLS UNTIL THE LOWER
LEVEL FLOOR AND MAIN LEVEL FLOOR ARE IN PLACE AND PROPERLY ANCHORED.
CONCRETE SLABS SHALL BE PROPERLY CURED.
G. CENTER ALL FOOTINGS UNDER WALLS, COLUMNS OR GRID LINES UNLESS NOTED
OTHERWISE ON PLANS.
H. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTED
FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE.
I. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAY
BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.
J. FOR SOIL DRAINAGE REQUIREMENTS REFER TO SOILS REPORT AND CIVIL DRAWINGS.
5. CONCRETE
A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT,
STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:
CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.
FOOTINGS 3000 psi STD --- ---
FOUNDATION WALLS (RESIDENTIAL) 3000 psi STD --- ---
ARCHITECTURALLY EXPOSED
EXTERIOR CONCRETE WALLS 4500 psi STD 0.45 6%-8%
GRADE BEAMS (*) 4000 psi STD --- ---
INTERIOR SLABS ON GRADE (RESIDENTIAL) 4000 psi STD 0.50 ---
EXTERIOR CONCRETE (++) 4500 psi STD 0.45 6%-8%
+FOR ALL CONCRETE SUBJECT TO SULFATE ATTACK OR POSSIBLE CONTACT WITH ROAD
SALTS W/C RATIO SHALL NOT EXCEED 0.4.
++MAXIMUM SLUMP SHALL NOT EXCEED 4".
B. THE MODULUS OF ELASTICITY OF ALL CONCRETE SHALL EXCEED WC1.5 33 ?F'C (OR
57,000 ?F'C NORMAL WEIGHT CONCRETE). GENERAL CONTRACTOR TO PROVIDE THE
ENGINEER OF RECORD WITH MODULUS OF ELASTICITY TEST RESULT.
C. CALCIUM CHLORIDE SHALL NOT BE USED. FLYASH (CLASS C) SHALL NOT BE USED.
POZZOLANS SHALL NOT BE USED WITHOUT PRIOR APPROVAL BY ENGINEER OF
RECORD. IF APPROVED, POZZOLANS SHALL BE LIMITED TO (25) % OF CEMENT CONTENT
BY WEIGHT IN ALL STRUCTURAL ELEMENTS. IF CONCRETE SUPPLIER PROPOSES USE OF
POZZOLANS HE SHALL PROVIDE OWNER WITH LETTER INDICATING COST REDUCTION AT
TIME OF BID.
D. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTS
SHALL BE SPACED AT 12 FEET MAXIMUM AND NOT EXCEEDING 144 SQUARE FEET.
SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16" WIDE WITHIN 12 HOURS AFTER
POURING. CARRY ALL SLAB REINFORCEMENT THROUGH JOINT. CONTRACTOR TO
COORDINATE EXACT JOINT LAYOUT WITH ARCHITECT OF RECORD.
E. SLABS, TOPPING, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A
HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF
SPAN WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE
SHOWN. ALL CONSTRUCTION JOINTS SHALL BE AS DETAILED OR AS REVIEWED BY THE
ENGINEER.
F. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE
WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USE
STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OF
CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.
6. REINFORCEMENT
A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM
A615, GRADE 60 EXCEPT TIES, STIRRUPS AND PLATE ANCHORS WHICH SHALL BE
DEFORMED BARS, ASTM DESIGNATION A615, GRADE 40 OR ASTM A706 GRADE 60.
B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BE
LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER.
C. REINFORCEMENT CLEAR COVER PROTECTION MILDLY REINFORCED UNLESS NOTED
OTHERWISE:
1. CONCRETE POURED AGAINST EARTH 3"
2. CONCRETE POURED ON VOID FORM 2"
3. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH)
BARS #5 AND SMALLER 1-1/2"
BARS LARGER THAN #5 2"
4. COLUMNS AND BEAMS (TIE BARS) 1-1/2"
5. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4"
D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH
OF ACI 318, LATEST EDITION.
E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR
AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALL
BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE A
MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTED
OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.
F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS IN
CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY AT
EACH CORNER.
G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED AS
FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS.
H. PLACE (3)-#5 VERTICALLY FULL HEIGHT OF CONCRETE WALLS AT HIGH SIDE OF ALL
WALL STEPS GREATER THAN 4'-0", IN ADDITIONAL TO WALL REINFORCING SHOWN ON
PLANS.
7. POST-INSTALLED ANCHORAGES
A. ALL POST-INSTALLED ANCHORS AND BOLTS SHALL MEET ICC-ES COMPLIANCE FOR
EACH TYPE OF APPLICATION.
B. ALL CONCRETE MUST BE A MINIMUM OF 14 DAYS OLD AND ACHIEVED 100% OF f'c PRIOR
TO INSTALLATION OF ANCHORS.
C. GENERAL CONTRACTOR TO SUBMIT ALL POST-INSTALLED PRODUCT DATA FOR REVIEW.
D. POST-INSTALLED ANCHORAGES SHALL BE INSTALLED ACCORDING TO THE
MANUFACTURES REQUIREMENTS, INCLUDING THE PREPARATION AND CLEANING OUT
OF DRILLED HOLES.
E. THE FOLLOWING ARE THE ACCEPTABLE POST-INSTALLED ANCHORAGES AS
MANUFACTURED BY SIMPSON STRONG-TIE.
1. ADHESIVE ANCHORS IN CONCRETE SHALL BE SET-XP OR AT-XP
2. ADHESIVE ANCHORS IN SOLID GROUTED CMU SHALL BE SET-XP OR ET-HP
3. ADHESIVE ANCHORS IN HOLLOW CMU SHALL BE SET-XP
4. MECHANICAL ANCHORS IN CONCRETE SHALL BE STRONG-BOLT 2 OR TITEN HD
5. MECHANICAL ANCHORS IN CONCRETE ON METAL DECK SHALL BE STRONG-BOLT
2 OR TITEN HD
6. MECHANICAL ANCHORS IN SOLID GROUTED CMU SHALL BE STRONG-BOLT 2 OR
TITEN HD
7. MECHANICAL ANCHORS IN HOLLOW CMU SHALL BE TITEN OR TITEN HD.
F. ALTERNATES MUST BE REVIEWED BY THE ENGINEER OF RECORD PRIOR TO
INSTALLATION. GENERAL CONTRACTOR TO SUBMIT PRODUCT AND TESTING DATA,
INCLUDING MANUFACTURER'S INFORMATION AS WELL AS ICC EVALUATION SERVICES
REPORT.
8. STRUCTURAL STEEL
A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMS
WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICH
SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATEST
EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.
MISCELLANEOUS STRUCTURAL STEEL SHAPES SHALL CONFORM TO ASTM A36 UNLESS
NOTED OTHERWISE. MISCELLANEOUS EMBEDDED STEEL ITEMS SHALL BE A36 STEEL
UNLESS NOTED OTHERWISE.
B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHT
CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM F1554, GR. 36 UNLESS
NOTED OTHERWISE.
C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE
LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."
D. EXCEPT WHERE DETAILED OTHERWISE, FABRICATOR SHALL SELECT STEEL
CONNECTIONS PER AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A
AND/OR AISC "SIMPLE SHEAR CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED
EQUIVALENT) TO SUPPORT LOADS INDICATED ON THE STRUCTURAL DRAWINGS. WHEN
LOADS ARE NOT SHOWN, SELECT CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM
LOAD CAPACITY PER AISC "MANUAL OF STEEL CONSTRUCTION" FOR EACH GIVEN BEAM
AND SPAN FOR NON-COMPOSITE MEMBERS.
SUBMIT DESIGN CALCULATIONS, BEARING THE STAMP AND SIGNATURE OF THE
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO, AND EMPLOYED BY
THE STEEL FABRICATOR, FOR ALL CONNECTIONS NOT COMPLETELY DETAILED ON THE
STRUCTURAL DRAWINGS AND FOR ANY PROPOSED ALTERNATE CONNECTION DETAILS.
E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY
STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1.
F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16" CONTINUOUS
FILLET UNLESS NOTED OTHERWISE.
G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORT
SLOTS IN CONNECTION MEMBER ONLY (WT-SECTIONS, ANGLES OR SHEAR PLATES).
H. STRUCTURAL STEEL SUPPLIER TO FURNISH LINTELS FOR ALL MASONRY OPENINGS PER
LOOSE LINTEL SCHEDULE OR AS SHOWN OTHERWISE ON STRUCTURAL DRAWINGS. ONE
END OF THE LINTEL SHALL BE FREE TO MOVE HORIZONTALLY TO ALLOW FOR
ELONGATION AND SHORTENING.
I. THE TERMINOLOGY "CONTINUOUS" MEANS QUANTITY. PROVIDE THE NECESSARY JOINT
DETAILS TO ALLOW FOR BUILDING MOVEMENTS. COORDINATE LOCATIONS WITH
ARCHITECTURAL CONTROL AND EXPANSION JOINTS.
J. PROVIDE ANCHOR BOLTS FOR BEAMS BEARING ON CONCRETE UNLESS OTHERWISE
NOTED.
K. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALL
STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR
LATERAL LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT
LATERAL SYSTEMS AND DECKS ARE IN PLACE.
L. STEEL FABRICATOR SHALL NOT RECEIVE ADDITIONAL COMPENSATION FOR SHOP
DRAWING TIME FOR ANY REVISIONS TO ERECTION DRAWINGS NOR FOR ANY REVISIONS
TO PIECE DRAWINGS PRIOR TO ENGINEER'S APPROVAL OF ERECTION DRAWINGS.
M. UNLESS NOTED OTHERWISE, WHENEVER MASONRY RESTS ON STEEL BEAMS WITH
FLANGES NARROWER THAN ACTUAL MASONRY THICKNESS, WELD 1/4" THICK
CONTINUOUS PLATE TO BEAM FLANGE. WIDTH OF PLATE TO BE 1/2" NARROWER THAN
MASONRY THICKNESS.
9. NON-SHRINK GROUT
A. NON-SHRINK GROUT SHALL BE PROVIDED:
1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS.
2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRY
SUPPORTS.
3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTH
OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.
10. WOOD
A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BY
WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL
BUILDING CODE AS FOLLOWS:
2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSI
2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSI
5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSI
NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITIVE USES PRIOR
TO ALLOWABLE STRESS INCREASES.
B. ALL LUMBER IN CONTACT WITH CONCRETE, MASONRY, WITHIN 8 INCHES FROM
EXPOSED EARTH OR EXPOSED TO EXTERIOR ELEMENTS SHALL BE PRESERVATIVE
TREATED LUMBER IN ACCORDANCE WITH AWPA U1 WITH A SERVICE CONDITION AS
REQUIRED FOR USE OR NATURALLY DURABLE WOOD PER IBC2304.
C. WHEN PRESERVATIVE TREATED LUMBER IS REQUIRED BY CODE ALL CONNECTIONS AND
NAILING SHALL BE ADEQUATELY GALVANIZED (DOUBLE DIPPED OR BETTER).
D. PROVIDE METAL CROSS BRIDGING NOT OVER 8' ON CENTER FOR ALL 2X WOOD JOISTS.
SOLID BLOCKING BETWEEN ALL JOISTS AT ALL SUPPORTS AND ENDS OF CANTILEVERS
IS REQUIRED.
E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULE
TABLE 2304.10.1 UNLESS NOTED OTHERWISE.
F. NOTCHES AND BORED HOLE PENETRATIONS IN WOOD STUD WALLS SHALL CONFORM
TO SECTION 2308 OF THE INTERNATIONAL BUILDING CODE.
G. LAMINATED BEAMS
1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH AT
LESS THAN 12 PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL
SIZES SHOWN ARE NET.
2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCE
WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF
STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC.
3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUS
MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.
MEMBERS SHALL BE DESIGNED WITH ZERO CAMBER WITH TOP SURFACE
CLEARLY STAMPED ON EACH MEMBER. (IF LAMINATED COLUMNS ARE USED,
SPECIFY ACCORDINGLY, GRADE "DF L2)
H. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.
1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL
BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE
AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF
U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS
WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THE
WEATHER SHALL BE OF THE EXTERIOR TYPE.
3. FOR FLOORING USE 3/4" T&G STURD-I-FLOOR SHEATHING GLUED AND NAILED
WITH 10D NAILS AT 6" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
4. FOR ROOF USE 5/8" (40/20 SPAN RATING) EXPOSURE I SHEATHING NAILED
WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES AND AT 12" ALONG
INTERMEDIATE SUPPORTS.
5. EXTERIOR WALLS SHALL HAVE ONE LAYER OF 1/2" EXPOSURE I PLYWOOD OR
OSB SHEATHING NAILED WITH 8d (OR 10d) NAILS AT 6" ON CENTER ALONG PANEL
EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS. ALL PANEL EDGES
SHALL BE BLOCKED.
6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN
PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.
7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE AND
GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.
I. WOOD DECK
WOOD DECKING SHALL BE 2x T&G DOUGLAS-FIR LARCH (E=1,700,000 PSI, Fb=1450 PSI).
PLANKS SHALL BE SPLICED AT CENTER OF SUPPORT MEMBERS WITH ADJACENT
PLANKS SPLICED AT ALTERNATE SUPPORT MEMBERS. EACH DECK PLANK SHALL BE
SLANT-NAILED TO THE TONGUE OF THE ADJOINING COURSE WITH 8d NAILS AT 24" ON
CENTER WITH ALTERNATE PLANK NAILING OFFSET 12". NAIL EACH PLANK TO EACH
SUPPORT WITH (2)-16d NAILS-1 STRAIGHT, 1 SLANTED. WOOD DECKING SHALL BE GLUED
IN THE GROOVE JOINT WITH 40% GLUE COVERAGE.
J. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS AND
SHALL BE "BCI-JOIST" AS MANUFACTURED BY BOISE CASCADE. ALTERNATES SHALL BE
REVIEWED BY THE ENGINEER. TO BE CONSIDERED, ALTERNATES SHALL HAVE A LOAD
CAPACITY IN BENDING, SHEAR AND DEFLECTION EQUAL TO OR GREATER THAN THE
SIZE SHOWN ON THE DRAWINGS. WEB BLOCKING AND BRIDGING TO BE AS REQUIRED
BY THE JOIST MANUFACTURER.
K. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESS
CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UP
MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS'
RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" OR
5 1/4" WIDE MEMBERS.
L. ALL SOLID SAWN, LAMINATED VENEER LUMBER, AND PREFABRICATED WOOD MEMBER
HANGERS ARE TO BE INSTALLED USING THE MAXIMUM NUMBER OF FASTENERS AS
SPECIFIED BY THE HANGER MANUFACTURER, UNLESS NOTED OTHERWISE.
M. ALL WOOD HANGERS ARE TO BE THE TYPE NOTED ON THE DRAWINGS AND SHALL BE
MANUFACTURED BY SIMPSON STRONG-TIE. ALTERNATES SHALL HAVE EQUAL OR
GREATER CAPACITY.
11. NON-STRUCTURAL ELEMENTS
A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR
SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND
OTHER STRUCTURAL MOVEMENTS.
B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEET
ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THE
ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDERED
UNRESTRAINED UNLESS NOTED OTHERWISE.
12. GENERAL
A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.
B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL AND
ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS AND
REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.
C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHER
ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONS
AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ON
ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTOR
SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OF
HIS ITEMS.
D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL,
MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDED
ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLED
BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36.
E. PROVIDE ASPHALTIC MASTIC-COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.
F. SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL
STRUCTURAL STEEL. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TO
WRITTEN REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE
CONTRACTOR. SHOP DRAWINGS NOT REVIEWED AND STAMPED BY CONTRACTOR
PRIOR TO SUBMITTING WILL BE RETURNED AND NOT REVIEWED.
G. WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THE
ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.
H. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIOR
WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.
I. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD
CONDITIONS AND ARCHITECTURAL DRAWINGS.
J. CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONS
ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER. (FOR RENOVATIONS OR
ADDITIONS)
K. PRE-MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL
HAVE ALL ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND
SHALL BE SUBMITTED FOR ARCHITECTS REVIEW BEARING THE SEAL OF A
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF COLORADO. STAIRS SHALL
BE DESIGNED TO SUPPORT A LIVE LOAD OF 100 PSF. SEE ARCHITECTURAL DRAWINGS
FOR ADDITIONAL REQUIREMENTS AND CRITERIA.
L. ALL HOUSEKEEPING PAD LOCATIONS AND EXTENTS SHALL BE COORDINATED WITH
ARCHITECTURAL AND MECHANICAL DRAWINGS.6'-0" MAXIMUM3'-0" MINIMUM 1'-0" MIN.
SECTION 1
3/4" = 1'-0"
NOTES:
1. FILL BEHIND BOULDERS SHALL BE SELF COMPACTING, FREE-DRAINING GRAVEL.
2, ALL BOULDERS SHALL BE RECTANGULAR SHAPED, WITH FLAT CONTACT SURFACES.
3. BOULDER JOINTS SHALL BE OFFSET ALONG LENGTH OF WALL.
4. CONTACT SURFACES BETWEEN BOULDERS SHALL BE GROUTED OR HAVE SANDBED.
GRADE
BOULDER WALL
PERMANENT SHORING
WALL
SHEAR WALL SCHEDULE
MATERIAL ATTACHMENTS AND VALUE PER THE 2018 IBC
PLAN MARK ANCHOR BOLTS AT
FOUNDATION OR
STRUCTURAL SLAB
BLOCKING / RIM
ATTACHMENT TO WALL
PLATES
SW1
XX
WALL SHEATHING
AND ATTACHMENT
7/16" OSB SHEATHING WITH
8d COMMONS 6" O.C.
EDGES, 12" O.C. FIELD
FRAMING MEMBERS
AT ABUTTING
PANEL EDGES
2X
SILL PLATE CONNECTION TO
BLOCKING / RIM AT FRAMED FLOORS
(USE SHEAR WALL MARK BELOW FLOOR)
16d COMMON NAILS AT 5" O.C. INTO
SOLID BLOCKING OR SDS 1/4" X 4 1/2"
WOOD SCREWS AT 9" OR SIMPSON A35
AT 1'-9" MAX.
1/2"Ø X 10" A.B. OR
5/8" X 6 1/2" TITEN HD
AT 2'-6" O.C.
SIMPSON A35 OR
LTP4 AT 1'-9" MAX.
HOLDOWN SCHEDULE
SIMPSON HOLDOWN
FLOOR TO FLOOR ALTERNATE HOLDOWNSIMPSON HOLDOWN
AT CONCRETEMARK
A HDU2.5-SDS2.5
ANCHOR BOLT
5/8"Ø EPOXY
ANCHOR WITH 5"
EMBED INTO
CONCRETE
BOUNDARY COLUMN
(2)-2X6
(2)-HDU2-SDS2.5 WITH
5/8"Ø THREADED ROD
THRU FLOOR
ASSEMBLY
MSTC40
(36)-19d COMMON
B (2)-2X6
(2)-HDU2-SDS2.5 WITH
5/8"Ø THREADED ROD
THRU FLOOR
ASSEMBLY
HDU5-SDS2.5
NOTES:
1. ALL PLYWOOD PANEL EDGES SHALL BE BLOCKED. BLOCKING SHALL MATCH THE STUDS AT ADJOINING PANEL EDGES.
2. NAIL SPACING AT 12" O.C. ALONG INTERMEDIATE FRAMING MEMBERS.
3. STAGGER ALL SHEATHING JOINT AND SILL PLATE NAILING.
4. NAILS SHALL BE COMMON OR GALVANIZED BOX IN PLYWOOD SHEAR WALLS.
5. ALL PLYWOOD PANELS SHALL BE APA RATED EXPOSURE 1 SHEATHING, UNLESS NOTED OTHERWISE.
6. EXTENT OF SHEAR WALL INDICATED BY ON PLAN.
7. ALL EXTERIOR WALLS SHALL BE TYPE U.N.O.
NOTES:
1. SIMPSON HOLDOWNS SHALL BE AS NOTED ON PLAN AND INSTALLED PER MANUFACTURER.
2. SIMPSON FLOOR TO FLOOR HOLDOWN STRAPS SHALL BE AS NOTED ON PLANS. HOLDOWNS ARE CALLED OUT AT THE BOTTOM
OF THE SHEAR WALL ON PLAN, AND SHALL BE INSTALLED AT EACH END OF THE WALL.
3. MINIMUM HOLDOWN COLUMN AT EACH END SHALL BE (2)-2X6 FASTENED TOGETHER WITH NAILING EQUIVALENT TO THE PANEL EDGE NAILING.
4. ANCHOR BOLTS SHALL BE INSTALLED WITH A HEAVY HEX NUT, TIGHTEN PER HOLDOWN MANUFACTURER RECOMMENDATION,
SNUG TIGHT AND TURN 1/3 TURN (MINIMUM).
5. SEE DETAIL 7/S4.2 FOR HOLDOWN ANCHOR BOLT CONNECTION TO STEEL.
SW1
S#X
INDICATES HOLDOWN
TYPE AT EACH END OF WALL
INDICATES
SHEAR WALL TYPE
5/8"Ø EPOXY
ANCHOR WITH 5"
EMBED INTO
CONCRETE
1
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
GENERAL NOTES
S1.01469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
1 REVISED 11/19/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
( 8136' - 10" )
( 8134' - 0" )
( 8128' - 10" )
( 8131' - 6" )
( 8125' - 0" )
( 8128' - 4" )
[ 8131' - 10" ]
[ 8142' - 8 1/2" ]
[ 8156' - 3" ]
[ 8155' - 9 1/4" ]( 8140' - 10" ) ( 8144' - 10" )FOOTING
STEP
FOOTING
STEP
( 8140' - 10" ) ( 8144' - 10" )FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
[ 8155' - 9 1/4" ][ 8145' - 6" ] WALL
STEP
TOP OF SLAB
TOP OF SLAB
8156' - 5 1/4"
TOP OF SLAB
8144' - 5 1/4"
TOP OF SLAB
8129' - 6"
8132' - 3"
TOP OF SLAB .SLOPERE: ARCH8" CONCRETE SLAB ON GRADE
WITH #5 AT 10" EACH WAY
5" CONCRETE SLAB ON GRADE
WITH 6X6 W2.1XW2.1 W.W.F.
WALL
STEP
WALL
STEP[ 8155' - 9 1/4" ][ 8155' - 9 1/4" ][ 8143' - 3 1/8" ] [ 8144' - 3" ] [ 8146' - 6" ]( 8125' - 0" ) ( 8128' - 4" ) ( 8132' - 10" ) ( 8136' - 10" )( 8126' - 6" )( 8128' - 4" ) FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
[ 8155' - 9 1/4" ]
FOOTING
STEP
1' - 10" 1' - 6"3' - 0"
10"1' - 0" 1' - 0" 2' - 4"10"2' - 10"1' - 0" 3' - 10"10"1' - 6"1' - 0" 8"1' - 6"1' - 6"
8"
2' - 3"
1' - 1"
10"
10" 1' - 6"10" 2" 8"
2' - 0"
2' - 4"
8"
4' - 0"
[ 8141' - 0" ]1' - 6"8"8" 1' - 0"8"BEAM POCKET
RE: 8/S4.1
5'-6" X 5'-6" X 1'-0"
CONCRETE FOOTING
WITH (6)-#5 EACH WAY
WALL
STEP
WALL
STEP
4'-0" X 4'-0" X 1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY( 8128' - 4" )[ 8131' - 7" ]4' - 0"2' - 0"2' - 0"
WALL
STEP
WALL
STEP
WALL
STEP
[ 8132' - 2" ][ 8132' - 2" ]
8156' - 5 1/4"
8" CONCRETE SLAB ON GRADE
WITH #5 AT 10" EACH WAY
2' - 0"
WALL
STEP
WALL
STEP
NOTE: BACKFILLING OF FOUNDATION
SHALL CONSIST OF A MINIMUM HORIZONTAL
WIDTH OF 2'-0" OF GEO-FOAM BACKFILL
MATERIAL PLACED AGAINST FOUNDATION WALL,
EXTENDING FROM FOOTING TO 18"
BELOW FINAL GRADING
8
S3.1
1
S3.1
5
S3.1
6
S3.1
2
S3.1
3
S3.1
4
S3.1
PERMANENT SHORING WALL
BY OTHERS
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"9' - 6" 14' - 0" 21' - 7 1/2"15' - 11 1/2"5' - 1 7/8" 5' - 6 1/8" 9' - 3 1/2" 22' - 4" 12' - 0 3/8" 17' - 11 1/4"
20' - 0 3/8" 18' - 0" 5' - 9 5/8"3' - 9"59' - 4" 15' - 1 1/2" 8' - 0" 4' - 0" 6' - 0" 12' - 10 1/4" 3' - 10 1/4" 3' - 6" 6' - 10" 2' - 2" 4' - 10 1/4" 7' - 3 1/4" 13' - 7 3/4"8' - 6 1/2"WALL
STEP
7 1/2"
4 1/2"3' - 6 1/4" 1' - 0"10" 2"6' - 10 1/2"
8" 5"
1' - 1"8"6" 7"
[ 8143' - 5 3/4" ]
[ 8144' - 3" ]
[8165'-10"]
WALL
STEP
[ 8143' - 9 1/4" ]
WALL
STEP
WALL
STEP
{ 8129' - 0" }{ 8129' - 0" }
[ 8128' - 4" ]1' - 0"S2.0
2
[ 8142' - 10 7/8" ]
FOOTING
STEP
[ 8142' - 10 7/8" ]
( 8131' - 6" )
RE: S2.1 FOR CONCRETE
WALL ABOVE FRAMING
TOW = 8165'-10"
BOW = 8143'-5 3/4"
8" CONCRETE
RE: S2.2
1' - 0" 3' - 5"1' - 0"
WALL
STEP 1' - 5 3/8" 2' - 8 3/4"EMBED PLATE
RE: 19/S4.1 (SIM.)
EMBED PLATE
RE: 19/S4.1 (SIM.)
1' - 6 7/8" 13' - 3 5/8" 2' - 8"
8131' - 6"
T.O.CONC
8
S3.2
5
S3.2
3
S3.2
RE: NOTE 17
8129' - 6"
T.O.CONC
8129' - 0"
T.O.CONC ( 8128' - 10" ) BEAM POCKET
4
S3.2
6 1/2" 1' - 8"7
S3.2 10"2' - 0"10"BEAM POCKET6' - 5 1/2"5' - 8" ( 8148' - 10" )
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
( 8128' - 4" )( 8131' - 6" )
FOOTING
STEP
FOOTING
STEP
( 8131' - 6" )FOOTING
STEP 5' - 6 3/4"[ 8143' - 0" ] [ 8156' - 3" ]11 5/8"
[ 8160' - 9 1/8" ]
WALL STEP
7' - 1 1/4"
FOUNDATION NOTES:
1. INDICATES ELEVATION OF TOP OF FLOOR SHEATHING OR TOP OF
CONCRETE SLAB.
2. ALL SLAB-ON-GRADES ARE 4” THICK WITH 6x6-W2.1 x W2.1 W.W.F, U.N.O.
3. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND DETAILS WITH
ARCHITECTURAL DRAWINGS.
4. [XXX’-XX”] INDICATES TOP OF FOUNDATION WALL (GRADE BEAM) ELEVATION.
5. (XXX’-XX”) INDICATES TOP OF FOOTING ELEVATION.
6. {XXX’-XX”} INDICATES TOP OF LEDGE ELEVATION.
7. GENERAL CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS LISTED IN SOILS
REPORT.
8. INDICATES TOP OF SLAB STEP.
9. ALL CONCRETE WALLS ARE 8" THICK, U.N.O.
10. CONTRACTOR TO PLACE (3)-#5 VERTICALLY FULL HEIGHT OF WALL AT HIGH SIDE OF
ALL WALL STEPS GREATER THAN 4’-0” IN ADDITION TO WALL REINFORCING SHOWN
OTHERWISE.
11. FOOTING ELEVATIONS SHOWN ARE MAXIMUMS AND MAY NEED TO BE LOWERED DUE
TO SOIL CONDITIONS. VERIFY CHANGES WITH STRUCTURAL ENGINEER OF
RECORD PRIOR TO CONSTRUCTION.
12. PROVIDE CONTROL JOINTS OR CONSTRUCTION JOINTS PER GENERAL NOTES.
MAXIMUM SIZE OF EACH AREA SHALL NOT EXCEED 144 SQUARE FEET.
CONTRACTOR TO COORDINATE JOINT LAYOUT WITH ARCHITECT.
13. ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER ARCHITECTURAL
LANDSCAPE PLANS, DETAILS, AND ELEVATIONS. SITE WALLS SHALL NOT BE
CONNECTED TO THE BUILDING UNLESS NOTED OTHERWISE.
14. GEO-FOAM BACK FILL MATERIAL SHALL BE CONTROL GEO-FOAM 12 AS
MANUFACTURED BY R-CONTROL. ALTERNATIVE SHALL MEET ASTM D6817
AND SHALL BE OF EQUAL DENSITY AND MODULES OF ELASTICITY AND
COMPRESSIVE RESISTANCE.
15. PROVIDE 1/2"X8"X8" EMBED PLATES WITH (4)-1/2"Ø X 4" H.A.S. AT 2'-0" FOR COLUMN
ATTACHMENT, RE:9/S3.2. (PLATES REQUIRED ABOVE ELEVATION = 8144'-3")
3 3.9
A
[ 8142' - 8 1/2" ][ 8143' - 3 1/8" ]
[ 8142' - 7 5/8" ]
STEP
BOW
STEP
BOW
( 8137' - 0" )
WALL
STEP
WALL
STEP
= BOW 10"6 1/2"2' - 9 5/8" 6' - 9 3/4" 1' - 1" 7' - 3 5/8" 5' - 9 5/8"
6 1/2" 6 1/2"
T.O.BEAM POCKET
18' - 0"
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT ENTRY
FOUNDATION PLAN
S2.01469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT ENTRY FOUNDATION PLANMATCHLINE MATCHLINE1/4" = 1'-0"2
EAST UNIT ENTRY FOUNDATION
PLAN - TOP OF WALL
Revisions
PERMIT 9/15/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
(2)-9 1/4" LVL
(2)-11 7/8" LVL (2)-11 7/8" LVLAT ROOF
AT STOREFRONT
(2)-9 1/4" LVL9 1/4" LVLAT 1'-4"9 1/4" LVL
AT 1'-4"
2X10
AT 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
UP ONLY UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
STAIR AND
ELEVATOR
TOP OF
CONCRETE
8144' - 5 1/4"
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
RE: S2.0
BEAM POCKET
HSS 5X5X3/8
8143'-8"
TOP OF
PLYWOOD
(3)-2X6
UP
ONLY
(3)-2X6 8144'-5 1/4"
TOP OF
PLYWOOD
8
S4.1
6
S4.1
12
S4.1
3
S4.1
7
S4.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"EMBED.
PLATE, TYP.
EMBED.
PLATE, TYP.W10X22< 8144' - 3" >W18X86< 8144' - 3" >W16X31
< 8144' - 3" >W10X26< 8144' - 3" > W10X26
< 8144' - 3" >W10X26< 8144' - 3" >W10X26< 8144' - 3" >2
S3.1
3
S3.1
1
S3.1
2X6 AT 1'-4" BEARING WALL 8143'-10 3/4"
TOP OF
PLYWOOD HSS16X4X1/4< 8144' - 5 1/4" >HSS16X4X1/4< 8144' - 5 1/4" >HSS16X4X1/4< 8144' - 5 1/4" >HSS 6X6X1/4
UP ONLY 6" CL SPLICEW10X30
< 8142' - 11 1/4" >
HSS12X8X1/4
< 8146' - 0" >
20
S4.1
HSS 6X6X1/4
UP AND
DOWN
HSS 6X6X1/4
UP AND
DOWN
5
S4.2
W8X31
< 8143' - 5 3/4" >W8X31< 8143' - 5 3/4" >16
S4.1
2
S4.2
4
S3.2
WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT GUEST
FLOOR FRAMING PLAN
S2.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT GUEST FLOOR FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
UP
ONLY
(3)-11 7/8" LVL
(3)-11 7/8" LVL2X10
AT 1'-4"
UP
ONLY
UP
ONLY
UP
ONLY
(2)-11 7/8" LVL
2X10
AT 1'-4"
UP
ONLY
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
8" CONCRETE SLAB-ON-GRAD
WITH #5 AT 10" EACH WAY
RE: S2.0
11 7/8" BCI-6000
AT 1'-4"
HSS 4X4X3/8
HSS 4X4X3/8
UP
ONLY
8" CONCRETE SLAB-ON-GRAD
WITH #5 AT 10" EACH WAY
RE: S2.0
8156' - 5 1/4"
TOP OF
CONCRETE
HSS 4X4X1/4
(3)-2X10(3)-2X10 HSS 4X4X1/4 (3)-9 1/4" LVL (3)-9 1/4" LVL 8156'-5 1/4"
TOP OF
PLYWOOD 6" CL SPLICEHSS 4X4X1/4
HSS 4X4X1/4
HSS 4X4X1/4 8155'-8"
TOP OF
PLYWOOD
(3)-2X6
HSS 4X4X1/4
(3)-2X6
2X6 AT 1'-4"
BEARING STUD WALL
2X6 AT 1'-4"
BEARING STUD WALL
(3)-2X6
HSS 8X8X1/4
UP AND DOWN
HSS 8X8X1/4
UP AND DOWN
STAIR AND
ELEVATOR
11
S4.1
6
S4.1
9
S4.1
4
S4.1
10
S4.1
4
S3.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"(3)-11 7/8" LVL HSS16X4X1/4
< 8156' - 5" >W10X22< 8156' - 3" >HSS 6X6X1/4
UP AND DOWN
W14X43
< 8156' - 3" >W12X22< 8153' - 5 3/4" >HSS16X4X1/4
< 8156' - 5" >HSS16X4X1/4
< 8156' - 5" >SW1
SW1A
8156' - 5 1/4"
TOP OF
CONCRETE
8
S4.1SIM.W10X60< 8156' - 3" >W10X39
< 8156' - 3" >W10X26< 8156' - 3" >W10X54
< 8156' - 3" >1 3/4" X 11 7/8" LVL RIM 1 3/4" X 11 7/8" LVL RIMBEAM POCKET
RE: 8/S4.1 (SIM.)
BEAM POCKET
RE: 8/S4.1 (SIM.)
4
S3.2
HSS 6X6X1/4
UP AND DOWN
HSS 6X6X1/4
UP AND DOWN
5
S4.2
HSS4X4X1/4
3
S4.2
8
S3.1
UP
ONLY
UP
ONLY
SIMPSON HUC HANGER
WITH TITEN 1/4"ØX1 3/4"
SCREWS INTO CONCRETE
WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT LIVING
FLOOR FRAMING PLAN
S2.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT LIVING FLOOR FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
01/22/21
1 2 3 3.9 4
F
E
D
C
B
A
I
H
(3)-14" LVL(3)-16" LVL
14" LVL
SUB FASCIA
SUB FASCIA
14" LVL
SUB FASCIA
SUB FASCIA14" LVL (3)-14" LVL14" LVL SUB FASCIA14" LVL
(2)-14" LVL 0"14" LVL
AT 2'-0"(3)-16" LVL14" BCI60
AT 1'-0"
14" BCI60
AT 1'-4"
6' - 0"
5' - 0"(3)-14" LVL14" LVL SUB FASCIA14" LVL SUB FASCIA(3)-14" LVL(2)-14" LVLHSS8X6X3/814" LVL 14" LVL
14" LVL SUB FASCIASUB FASCIA
SUB FASCIA (2)-14" LVL14" LVL
AT 2'-0" 14" BCI60
AT 1'-4"
14" LVL
AT 2'-0"SLOPE SLOPESLOPE14" BCI60
AT 1'-4"
14" BCI60
AT 1'-0"
14" LVL
AT 2'-0"
14" LVL
14" LVL
SUB FASCIA
SUB FASCIA
2X6 AT 1'-4" BEARING WALL
14" LVL
AT 2'-0"
(2)-14" LVL
14" BCI60
AT 1'-0" 0"HSS 8X6X3/8HSS 8X6X3/8 (2)-14" LVLHSS 4X4X1/4
(3)-2X6
STUB COLUMN
6" SPLICEHSS 4X4X3/8
HSS 8X8X1/4HSS 8X8X1/4 2
S5.1
6
S5.1
3
S5.1
9' - 6" 14' - 0" 21' - 0" 3' - 0"6' - 8" 16' - 2 1/2" 9' - 3 1/2" 11' - 6" 15' - 2"HSS 5X5X1/2HSS 5X5X1/2
10
S4.1 SIM.HSS 6X6X1/4 SW1SW1 SW1SW1SW1A
SW1ASW1A SW1A8167'-0 7/8"
TOP OF
PLYWOOD
RE: X/SX
(2)-14" LVL
HSS18X6X5/8
< 8172' - 1 5/8" >
HSS18X6X3/8
< 8165' - 6" >
W16X26
< 8167' - 4" >
W18X35
< 8167' - 6" >
W14X22
< 8165' - 9 3/4" >
W14X22
< 8165' - 3 5/8" >WALL ABOVEHSS8X6X3/8
< 8169' - 2 5/8" >
RE: S2.7 FOR WEST
UNIT ROOF FRAMING
RE: S2.7 FOR WEST
UNIT ROOF FRAMING
HSS 6X6X1/4
HSS 6X6X1/4 (2)-9 1/2" LVL (2)-9 1/2" LVL(2)-14" LVL(3)-9 1/2" LVL 13
S5.1
10
S5.1
WOOD ROOF FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURED BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CASCADE. ALTERNATES
SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X8 AT 2X6 WALLS OR (2)-2X8 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET S1.0
FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. RE: ARCHITECT FIR CHIMNEY SIZES AND LOCATIONS NOT NOTED ON STRUCTURAL PLANS.
21. OVERFRAMING SHALL BE 2X6 MINIMUM AND SHALL BE POSTED DOWN TO MAIN FRAMING ON
A GRID NOT TO EXCEED 4'-0" X 4'-0" (16FT2).
22. RE: ARCHITECTURAL DRAWINGS FOR ALL OVERLOW SCUPPER LOCATIONS.
23 INDICATES MONENT CONNECTION.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
EAST UNIT ROOF
FRAMING PLAN
S2.31469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
EAST UNIT ROOF FRAMING PLANMATCHLINE Revisions
PERMIT 9/15/2020
01/22/21
5 6 7 8 9
P
O
N
M
L
K
Q
J
I
H
( 8149' - 1" )
[ 8161' - 9" ][ 8161' - 9" ]( 8146' - 10" )( 8142' - 10" ) ( 8146' - 10" )( 8149' - 1" ) [ 8149' - 3 1/4" ] ( 8138' - 11 1/2" )
[ 8149' - 3 1/4" ]
( 8134' - 10" )( 8131' - 0" ) [ 8149' - 9" ][ 8149' - 3 1/4" ]
( 8134' - 10" )
[ 8149' - 9" ][ 8149' - 9" ] ( 8132' - 6" ) [ 8149' - 8 1/4" ] [ 8137' - 1" ]( 8134' - 4" ) ( 8132' - 6" )
[ 8137' - 1" ]
[ 8137' - 2" ]
( 8128' - 0" )( 8149' - 1" )[ 8161' - 9" ]( 8145' - 4" ) ( 8141' - 4" ) ( 8137' - 4" ) ( 8137' - 4" )( 8136' - 2" )( 8132' - 6" )( 8128' - 0" )[ 8149' - 9" ][ 8137' - 2" ]FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP
FOOTING
STEP FOOTING
STEP
WALL
STEP
FOOTING
STEP
FOOTING
STEP
( 8137' - 4" )
FOOTING
STEP
WALL
STEP
WALL
STEP 10"10"3' - 10 3/4"4' - 0"4' - 0" 2' - 6" 6' - 6" 10"2' - 0" TOP OF SLAB
.SLOPERE: ARCH5" CONCRETE SLAB ON GRADE
WITH 6X6 W2.1XW2.1 W.W.F.
FOOTING
STEP( 8134' - 10" )8149' - 3 1/4"2' - 0" 10" 4' - 0"2' - 0" 4' - 0"10" 2' - 0" 10" 4' - 0"8" 1' - 0"
10"
8" 1' - 0"
10"2' - 0" 5' - 0"10"( 8134' - 10" )[ 8149' - 3 1/4" ]1' - 0" 1' - 6"2' - 0"10"10"
1' - 0" 2' - 0"1' - 8"8"8"
1' - 0"
1' - 6" 1' - 6"
2' - 0"
10"2' - 3"2' - 3" 8"8" 1' - 0"8"PERMANENT SHORING WALL
BY OTHERS
1
S3.1
5
S3.1
6
S3.1
1
S3.1
2
S3.1
7
S3.1
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
NOTE: BACKFILLING OF FOUNDATION
SHALL CONSIST OF A MINIMUM HORIZONTAL
WIDTH OF 2'-0" OF GEO-FOAM BACKFILL
MATERIAL PLACED AGAINST FOUNDATION WALL,
EXTENDING FROM FOOTING TO 18"
BELOW FINAL GRADING
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" 18' - 6" 18' - 7 1/2" 17' - 4 1/2" 7' - 6"2' - 6"6' - 6" 18' - 6" 24' - 0" 9' - 4 7/8" 3' - 8"1' - 0 7/8"
4' - 2"8' - 10 1/4"WALL
STEP
( 8137' - 0" )
TOP OF SLAB
8137' - 9"1' - 8" 1' - 6" 1' - 8" 2"10" [ 8134' - 4" ]
{ 8135' - 0" }
FOOTING
STEP
8135' - 6"
1
S3.2
2
S3.2
10"Ø CONC. PIER WITH
28"Ø BELLED FOOTING
(BIGFOOT OR EQUAL)8"( 8137' - 4" )
2"
S2.4
2
5'-6"X5'-6"X1'-0"
CONCRETE FOOTING
WITH (6)-#5 EACH WAY
BEAM
POCKET
8'-0"X8'-0"X1'-0" CONCRETE
FOOTING WITH #5 AT 1'-0"
EACH WAY
8137' - 0"
T.O.CONC
8
S3.2
8135' - 6"
T.O.CONC
8135' - 6"
T.O.CONC
8135' - 0"
T.O.CONC
4'-0"X4'-0"X1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY
4'-0"X4'-0"X1'-0"
CONCRETE FOOTING
WITH (5)-#5 EACH WAY
17' - 9 1/2" 30' - 1 1/4" 13' - 5 1/4"
5' - 11 1/4" 18' - 0"6' - 2"
( 8131' - 0" )
6
S3.2
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.6
EMBED PLATE
RE: S2.5 5' - 4 3/4" 7 1/4" 7 1/4"
7 1/4" 15' - 8 1/4" 1' - 3 1/4" 2' - 6 1/8"11' - 4 3/4"4' - 5" 13' - 11 1/4"1 3/4"EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
WALL
STEP
4"8 1/2"{ 8135' - 0" }4' - 1 5/8"[ 8134' - 4" ]3'-0" X 6'-2"
OPENING
(VERIFY WITH ARCH.)
FOUNDATION NOTES:
1. INDICATES ELEVATION OF TOP OF FLOOR SHEATHING OR TOP OF
CONCRETE SLAB.
2. ALL SLAB-ON-GRADES ARE 4” THICK WITH 6x6-W2.1 x W2.1 W.W.F, U.N.O.
3. CONTRACTOR TO COORDINATE ALL DIMENSIONS AND DETAILS WITH
ARCHITECTURAL DRAWINGS.
4. [XXX’-XX”] INDICATES TOP OF FOUNDATION WALL (GRADE BEAM) ELEVATION.
5. (XXX’-XX”) INDICATES TOP OF FOOTING ELEVATION.
6. {XXX’-XX”} INDICATES TOP OF LEDGE ELEVATION.
7. GENERAL CONTRACTOR SHALL FOLLOW ALL REQUIREMENTS LISTED IN SOILS
REPORT.
8. INDICATES TOP OF SLAB STEP.
9. ALL CONCRETE WALLS ARE 8" THICK, U.N.O.
10. CONTRACTOR TO PLACE (3)-#5 VERTICALLY FULL HEIGHT OF WALL AT HIGH SIDE OF
ALL WALL STEPS GREATER THAN 4’-0” IN ADDITION TO WALL REINFORCING SHOWN
OTHERWISE.
11. FOOTING ELEVATIONS SHOWN ARE MAXIMUMS AND MAY NEED TO BE LOWERED DUE
TO SOIL CONDITIONS. VERIFY CHANGES WITH STRUCTURAL ENGINEER OF
RECORD PRIOR TO CONSTRUCTION.
12. PROVIDE CONTROL JOINTS OR CONSTRUCTION JOINTS PER GENERAL NOTES.
MAXIMUM SIZE OF EACH AREA SHALL NOT EXCEED 144 SQUARE FEET.
CONTRACTOR TO COORDINATE JOINT LAYOUT WITH ARCHITECT.
13. ALL SITE WALLS NOT SHOWN ON THIS PLAN SHALL BE BUILT PER ARCHITECTURAL
LANDSCAPE PLANS, DETAILS, AND ELEVATIONS. SITE WALLS SHALL NOT BE
CONNECTED TO THE BUILDING UNLESS NOTED OTHERWISE.
14. GEO-FOAM BACK FILL MATERIAL SHALL BE CONTROL GEO-FOAM 12 AS
MANUFACTURED BY R-CONTROL. ALTERNATIVE SHALL MEET ASTM D6817
AND SHALL BE OF EQUAL DENSITY AND MODULES OF ELASTICITY AND
COMPRESSIVE RESISTANCE.
15. PROVIDE 1/2"X8"X8" EMBED PLATES WITH (4)-1/2"Ø X 4" H.A.S. AT 2'-0" FOR COLUMN
ATTACHMENT, RE:9/S3.2. (PLATES REQUIRED ABOVE ELEVATION = 8144'-3")
J
I
STEP
BOW
STEP
BOW
[ 8149' - 6 3/4" ]
( 8143' - 0" )
18' - 0" 5' - 4"
BEAM
POCKET
[ 8143' - 0" ]B.O.W.9' - 4 3/4"
1' - 2"
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT ENTRY
FOUNDATION PLAN
S2.41469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT ENTRY FOUNDATION PLANMATC HLI NE MATC HLI NE1/4" = 1'-0"2
WEST UNIT ENTRY FOUNDATION
PLAN - TOP OF WALL
Revisions
PERMIT 9/15/2020
01/22/21
5 6 7 8 9
P
O
N
M
L
K
Q
J
I
H
8" CONCRETE SLAB-ON-GRADE
WITH #5 AT 10" EACH WAY
2X10
AT 1'-6"
(TREATED)
6X6 POST(2)-11 7/8" LVLUP
ONLY
UP
ONLY
HSS 4X4X3/8
1/4" PLATE
STEEL SADDLE
11 7/8" BCI-6000
AT 1'-4"11 7/8" BCI-6000
AT 1'-4"
UP
ONLY
UP
ONLY
2X10
AT 1'-6"
(TREATED)
HSS 4X4X1/4
UP AND DOWN
2X6 AT 1'-4"
BEARING STUD WALL
HSS 5X5X3/8 DOWN
HSS 5X5X1/4 UP
(3)-2X6
HSS 4X4X1/4
HSS6X6X1/4
UP ONLY
UP
ONLY
HSS12X8X1/4
OVER (3)-16" LVL AT ROOF LEVEL
EXTERIOR GLASS
WALL ABOVE
9 1/4" LVL
AT 1'-4"(2)-9 1/4" LVL9 1/4" LVL
AT 1'-4"
HSS 4X4X3/16 HSS 4X4X3/16
11 7/8" BCI-6000
AT 1'-4"
11 7/8" BCI-6000
AT 1'-4"
STAIR AND
ELEVATOR
8149'-11 1/4"
TOP OF
CONCRETE
8149'-11 1/4"
TOP OF
PLYWOOD
8149'-2"
TOP OF
PLYWOOD
HSS 4X4X1/4
7
S3.1
2
S3.1
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" (2)-2X10(2)-2X10
8149'-6"
TOP OF
DECKING
W18X86< 8149' - 9" >W16X26
< 8149' - 9" >
W10X30
< 8148' - 5 1/4" >
8149'-4 3/4"
TOP OF
PLYWOOD
2X6 AT 1'-4" BRG. WALL
HSS16X4X1/4< 8149' - 10 1/2" >HSS16X4X1/4< 8149' - 10 1/2" >HSS16X4X1/4< 8149' - 10 1/2" >HSS4X4X1/4
(2)-11 7/8" LVL
15
S4.1
16
S4.1
14
S4.1
BEAM POCKET
WITH C9X15
EMBED PLATE
RE: 19/S4.1 (SIM.)
8
S4.1
4
S4.2
5
S4.2
1
S3.2
1
S4.2
6
S3.2
HSS6X6X1/4
UP AND DOWN
HSS6X6X1/4
UP AND DOWN
2
S3.2
(2)-11 7/8" LVLWOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT GUEST
FLOOR FRAMING PLAN
S2.51469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT GUEST FLOOR FRAMING PLANMATC HLI NE MATC HLI NERevisions
PERMIT 9/15/2020
01/22/21
3.9 4
5 6 7 8 9
E
D
C
P
O
N
M
L
K
Q
J
I
H
HSS 4X4X1/4
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY
UP
ONLY2 3/4"2 3/4"2 3/4"HSS 5X5X3/8
(2)-11 7/8" LVL
HSS 6X6X1/4
UP AND DOWN
(3)-11 7/8" LVL
(3)-2X6
2X6 AT 1'-4"
BEARING WALL
STONE VENEER
ABOVE
STONE VENEER
ABOVE
HSS 5X5X1/4 UP
ONLY
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
HSS 4X4X1/4
HSS 4X4X3/8
11 7/8" BCI-60
AT 1'-4"
9 1/2" BCI-6000
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
11 7/8" BCI-60
AT 1'-4"
EXTERIOR
STUD WALL ABOVE
EXTERIOR
STUD WALL ABOVE
2X6 AT 1'-4"
BEARING STUD WALL
11 7/8" BCI-60
AT 1'-4"(2)-11 7/8" LVLSTAIR AND
ELEVATOR
8161'-11 1/4"
TOP OF
PLYWOOD
5
S4.1 SIM.4
S3.1
7
S3.1
18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" W10X15< 8160' - 11 3/4" >W8X21
< 8160' - 11 3/4" >
W10X39
< 8160' - 11 3/4" >
8161'-2"
TOP OF
PLYWOOD W10X88 < 8161' - 9" >W16X31
< 8161' - 9" >
W12X35
< 8161' - 9" >
W10X22
< 8161' - 9" >W10X45< 8161' - 9" >W10X45
< 8161' - 9" >
W10X22
< 8161' - 9" > W10X39< 8161' - 9" >W10X39< 8161' - 9" >(2)-11 7/8" LVL
< 8161' - 9" >W10X22< 8161' - 9" >11 7/8" BCI-60AT 1'-4"W10X19
< 8161' - 9" >
W10X19
< 8161' - 9" >
HSS4X4X1/4
(2)-11 7/8" LVL W16X26
EMBED PLATE
RE: 19/S4.1
EMBED PLATE
RE: 19/S4.1
19
S4.1
1
S4.1
5
S4.1
HSS8X8X1/4HSS8X8X1/4 HSS16X4X1/4< 8161' - 10 1/2" >HSS16X4X1/4< 8161' - 10 1/2" >HSS16X4X1/4< 8161' - 10 1/2" >HSS8X6X5/8
UP
HSS4X4X1/4
DOWN
EMBED PLATE
RE: 19/S4.1
9 1/2" BCI-6000
AT 1'-4"
(3)-11 7/8" LVL
HSS4X4X1/4
1
S4.1
EMBED PLATE
RE: 19/S4.1
EMBED PLATE
RE: 19/S4.1
HSS 6X6X1/4
UP AND DOWN
HSS 6X6X1/4
UP AND DOWN
5
S4.2 (2)-9 1/2" LVL2
S3.2
1
S3.2
HSS4X4X1/4
UP
ONLY
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
EMBED PLATE
COLUMN CONNECTION
RE: 8/S4.2
7
S3.1
(SIM.)UP
ONLY
UP
ONLY
2X6 AT 1'-4" BEARING WALL
6
S4.2
UP
ONLY
UP
ONLY WOOD FLOOR FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURER BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURER BY BOISE CASCADE.
ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE
STRUCTURAL GENERAL NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X10 AT 2X6 WALLS OR (2)-2X10 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH
SIMPSON STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET
S1.0 FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. PROVIDE 3/8” X 2” X 2” STEEL PLATE WASHER BETWEEN THE SILL PLATE AND NUT AT ALL
ANCHOR BOLTS IN EXTERIOR WALLS AND DESIGNATED SHEAR WALLS.
21. INDICATES MOMENT CONNECTION SEE DETAIL FOR REQUIREMENTS.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT LIVING
FLOOR FRAMING PLAN
S2.61469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT LIVING FLOOR FRAMING PLANMATC HLI NE MATC HLI NERevisions
PERMIT 9/15/2020
01/22/21
3.9 4
5 6 7 8 9
E
D
C
P
O
N
M
L
K
Q
J
I
H
OR W14X22
(2)-14" LVL(2)-14" LVL(2)-14" LVL
HSS20X8X5/8 (2)-9 1/2" LVL
(2)-9 1/2" LVL (2)-9 1/2" LVL(2)-9 1/2" LVL DOUBLE 14" BCI-90
AT 2'-0"
DOUBLE 14" BCI-90
AT 2'-0"
9 1/2" LVL
AT 2'-0"
9 1/2" LVL
AT 2'-0"
9 1/2" BCI-6000
AT 1'-4"(2)-14" LVL (3)-9 1/2" LVL (2)-9 1/2" LVL (3)-9 1/2" LVL (3)-9 1/2" LVL
HSS 4X4X1/4HSS 4X4X1/4
(2)-14" LVL 0"14" LVL
AT 2'-0"
14" BCI-90
AT 2'-0"
STUB COLUMN
14" LVL
AT 2'-0"
DOUBLE 14" BCI-90
AT 2'-0"(2)-14" LVL(2)-14" LVLHSS 8X8X1/4 HSS 8X8X1/4
14" BCI-90
AT 2'-0"
14" LVL
AT 2'-0"
(3)-2X6
2X6 AT 1'-4" BRG. WALL
14" LVL
AT 2'-0"
(3)-2X6 (3)-2X6
(3)-2X6 (3)-2X6
DOUBLE 16" BCI-90
AT 2'-0" 0"AT TRANSOM 0"AT TRANSOM
HSS 10X6X3/8
HSS 10X6X3/8
(3)-11 7/8" LVL(3)-11 7/8" LVL 0" 0"4
S5.1
2 3/8"2 3/8"18' - 6" 19' - 0" 17' - 0" 7' - 6"2' - 0"7' - 0" 9' - 7 3/4" 8' - 10 1/4" 6' - 0" 5' - 6" 8' - 0" 4' - 6" 9' - 0" (3)-16" LVL
(3)-16" LVL
(2)-14" LVL (2)-14" LVL
HSS 8X6X5/8
HSS 5X5X1/2
8173'-5 1/2"
TOP OF
PLYWOOD
(3)-11 7/8" LVL (3)-11 7/8" LVLSW1 SW1SW1ASW12/129 1/2" LVL
SUBFASCIA
8171'-11 1/4"
TOP OF
PLYWOOD
9 1/2" LVL
SUBFASCIA SW1(2)-9 1/2" LVL 0"
18
S4.1
7
S5.1
8
S5.1
W18X40
< 8177' - 6 3/8" >
HSS8X6X3/8
< 8171' - 0" >
HSS8X6X3/8
< 8171' - 0" >
W14X22
< 8177' - 1 3/8" >WALL ABOVEHSS8X6X3/8
< 8176' - 2 5/8" >
W12X26
< 8173' - 4 3/4" >
W12X26
< 8175' - 8 7/8" >
W12X30
< 8175' - 8 7/8" >
W12X26
< 8175' - 8 7/8" >
W18X40
< 8171' - 11 7/8" >2:12HSS4X4X3/8
HSS8X6X5/8
HSS6X6X1/4
HSS6X6X1/4
HSS6X6X1/4
12
S5.1
(3)-9 1/2" LVL(3)-11 7/8" LVL STUB
COLUMNSW1ASW1A5
S5.1
(2)-14" LVL(2)-14" LVL13
S5.1
5
S5.1
11
S5.1
10
S5.1
9
S5.1
WOOD ROOF FRAMING NOTES:
1. ALL WOOD FRAMING JOISTS SHALL BE BCI TYPE JOISTS AS MANUFACTURED BY BOISE
CASCADE. ALTERNATES SHALL HAVE EQUAL OR GREATER CAPACITY AND SHALL BE
REVIEWED BY THE ENGINEER OF RECORD.
2. “LVL” INDICATES VERSA-LAM BEAMS, AS MANUFACTURED BY BOISE CASCADE. ALTERNATES
SHALL HAVE EQUAL OR GREATER CAPACITY AS LISTED IN THE STRUCTURAL GENERAL
NOTES.
3. INDICATES COLUMN DOWN ONLY. MULTIPLE 2X FRAMING NOTED ON PLANS.
4. INDICATES COLUMN UP AND DOWN UNLESS IT BEARS ON CONCRETE WALL OR
FOOTING BELOW, OR IS LABELED AS UP ONLY.
5. <XXX’-XX”> INDICATES TOP OF BEAM ELEVATION OR WALL PLATE HEIGHT ELEVATION.
6. INDICATES TOP OF STRUCTURAL FLOOR SHEATHING ELEVATION.
7. INDICATES INTERIOR BEARING WALLS. FLOOR JOIST BEARING
LOCATIONS SHALL LINE UP WITH STUDS BELOW.
8. HEADERS SHALL BE (3)-2X8 AT 2X6 WALLS OR (2)-2X8 AT 2X4 WALLS UNLESS NOTED
OTHERWISE. ALL HEADERS SHALL BE BUILT OUT TO 5 ½” OR 3 ½” WIDTH BY ADDING
PLYWOOD OR INSULATION SPACERS AS REQUIRED.
9. ALL COLUMNS SHALL BE (3)-2X6 AT 2X6 WALLS OR (3)-2X4 AT 2X4 WALLS UNLESS NOTED
OTHERWISE.
10. WOOD COLUMNS SHALL BE CONTINUOUS FROM FLOOR TO FLOOR OR FLOOR TO ROOF.
TRIMMERS SHALL BE ADDED TO NOTED COLUMN SIZES AS REQUIRED.
11. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED USING 2X6 STUDS. ALL EXTERIOR WALLS
SHALL HAVE CONTINUOUS STUDS FROM FLOOR TO FLOOR OR FLOOR TO ROOF
(INCLUDING RAKE WALLS).
12. ALL BEAM-TO-BEAM AND BEAM-TO-COLUMN CONNECTIONS SHALL BE MADE WITH SIMPSON
STEEL PLATE CONNECTORS UNLESS NOTED OTHERWISE.
13. RE: ARCHITECTURAL DRAWINGS FOR LOCATIONS AND SIZE OF ROUGH OPENINGS IN
WOOD STUD WALLS.
14. RE: ARCHITECTURAL DRAWINGS FOR HANDRAIL AND STAIR FRAMING DETAILS.
15. EXTENT OF WOOD SHEAR WALL BELOW DENOTED BY , RE: SHEET S1.0
FOR SHEAR WALL AND HOLD DOWN SCHEDULE.
16. FASTEN BOTTOM PLATES OF SHEAR WALLS TO FLOOR SHEATHING WITH (3)-ROWS OF 16d
NAILS AT 8” WHERE SHEAR WALLS DO NOT ALIGN VERTICALLY.
17. HOLD DOWNS OR STRAPS ARE CALLED OUT ON PLAN AT BOTTOM OF SHEAR WALL
WHERE REQUIRED. MINIMUM HOLD DOWN COLUMN SHALL BE (2)-2X6 AT WALL ENDS, OR
AS REQUIRED BY SHEAR WALL SCHEDULE.
18. STAGGER ALL SHEATHING JOINTS AND SILL PLATE NAILING.
19. NAIL HEADS SHALL NOT PENETRATE PLYWOOD.
20. RE: ARCHITECT FIR CHIMNEY SIZES AND LOCATIONS NOT NOTED ON STRUCTURAL PLANS.
21. OVERFRAMING SHALL BE 2X6 MINIMUM AND SHALL BE POSTED DOWN TO MAIN FRAMING ON
A GRID NOT TO EXCEED 4'-0" X 4'-0" (16FT2).
22. RE: ARCHITECTURAL DRAWINGS FOR ALL OVERLOW SCUPPER LOCATIONS.
23 INDICATES MONENT CONNECTION.
S#X
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
WEST UNIT ROOF
FRAMING PLAN
S2.71469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
1/4" = 1'-0"
WEST UNIT ROOF FRAMING PLANMATCHLINE MATCHLINERevisions
PERMIT 9/15/2020
01/22/21
RE: PLAN
RE: PLAN
2"3"CLR.RE: PLAN3" CLR.2" CLR.
RE: PLAN 1'-0" 7"
1'-1"2'-6"10"10"RE:PLAN
1'-0"10"RE: PLAN8"1'-0"
RE: PLAN1'-0"2" CLR.
10"1'-0"1'-0"1'-0" 1'-0"RE: PLAN
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL
AND HORIZONTAL
RE: PLAN
TOP OF
PLYWOOD
1 1/2" CONCRETE
TOPPING
EXTERIOR STUD WALL WITH
SHEATHING
2X TREATED PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
EXPOSED CONCRETE
FINISH RE: ARCH.
[XXX'-XX"]
RE: PLAN
(XXX'-XX")
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
#5 AT 1'-4" X 2'-6"1'-0"
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4 EACH WAY TOP
(2)-#5
RE: PLAN
(XXX'-XX")
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
#5 AT 1'-4" X 4'-0" 1'-6"
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4 EACH WAY TOP
(2)-#5
[XXX'-XX"]
RE: PLAN
TOP OF
CONCRETE
(2)-#5 TOP AND BOTTOM
FLOOR JOIST RE: PLAN
TREATED 2X10 WITH
1/2" Ø X 5" TITEN HD
CONCRETE SCREW ANCHOR
AT 2'-0"
#5 AT 1'-0" VERTICAL AND
HORIZONTAL
1 1/2" CONCRETE TOPPING
#5 AT 2'-0" X
2'-0"2'-0"8" CONCRETE SLAB-ON
GRADE
[XXX'-XX"]
RE: PLAN
TOP OF
CONCRETE
(2)-#5 TOP AND BOTTOM
FLOOR JOIST RE: PLAN
TREATED 2X10 WITH
1/2" Ø X 5" TITEN HD
CONCRETE SCREW ANCHOR
AT 2'-0"
#5 AT 1'-0" VERTICAL AND
HORIZONTAL
1 1/2" CONCRETE TOPPING
#5 AT 2'-0" X
2'-0"2'-0"8" CONCRETE SLAB-ON
GRADE
(XXX'-XX")
#5 AT 8" X 4'-0"1'-6"
#5 AT 1'-4 EACH WAY TOP
(2)-#5
5/8" Ø THREADED INSERT
AT 2'-0"
5/8" Ø X 2'-6" THREADED
ROD AT 2'-0"
8" CONCRETE SLAB
RE: PLAN
RE: PLAN
(XXX'-XX")
PARTY WALL RE: ARCH.
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR
BOLTS AT 2'-6"
RE: PLANRE: PLAN
TOP OF SLAB
{XXX'-XX"}
8" SLAB
RE: PLAN
#5 AT 1'-4" VERTICAL AND
HORIZONTAL EACH FACE
#5 AT 1'-4" X
EACH FACE 2'-6"1'-0"
2X4 FURRING WALL
TREATED 2X4 PLATE WITH
1/2" Ø X 10" ANCHOR BOLT
AT 2'-6"
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
SLOPE
#5 AT 1'-4" EACH WAY
(2)-#5 TOP AND
BOTTOM
DRIVEWAY BY
OTHERS
[XXX'-XX"]
CONSTRUCTION
JOINT
#5 AT 1'-4" HORIZONTAL
EACH FACE
#5 AT 1'-4" X
FULL HEIGHT1'-2"
#5 AT 1'-4" X
AS SHOWN1'-2"
(XXX'-XX")
#5 CONT.
DRIVEWAY BY
OTHERS
[XXX'-XX"]
#5 AT 1'-4" EACH FACE
#5 AT 2'-0" X
#5 AT 1'-4" X
EACH FACE
(XXX'-XX")
2'-0"2'-0"FULL HEIGHT1'-0"
SLAB-ON-GRADE
RE: PLAN
SLOPE
RE: ARCH.
(XXX'-XX")
5/8" Ø THREADED INSERT
AT 2'-0"
5/8" Ø X 2'-6" THREADED
ROD AT 2'-0"
8" CONCRETE SLAB
RE: PLAN
RE: PLAN
#5 AT 8" X
#5 AT 1'-0" TRANSVERSE
#5 AT 1'-4" LONGITUDINAL4'-0"2'-6"
(2)-#5
CONT.
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
RE: PLAN
TOP OF
PLYWOOD
1 1/2" CONCRETE
TOPPING
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
[XXX'-XX"]
2X TREATED PLATE WITH
1/2" Ø X 10" ANCHOR BOLT AT 2'-6"
WATERPROOFING AND FLASHING
RE: ARCH.
CONCRETE PATIO RE: ARCH.
(2)-#5 TOP AND BOTTOM
EXTERIOR WALL WITH
SHEATHING
SECTION 8
3/4" = 1'-0"
RE: PLAN
TOP OF
CONCRETE
[XXX'-XX"]
8" CONCRETE SLAB
RE: PLAN
FINISH FLOOR
RE: ARCH.
2X6 TREATED PLATE WITH
1/2" Ø ANCHOR BOLTS AT 2'-6"
PATIO RE: ARCH.
(XXX'-XX")
#5 AT 1'-4" HORIZONTAL
#5 AT 1'-0" VERTICAL
#5 AT 1'-0" X 2'-6"1'-2"
#5 AT 1'-4"
(2)-#5 TOP AND BOTTOM
(5)-#5 CONT.
RIGID INSULATION
.
.
.
.
.
.
.
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FOUNDATION
SECTIONS
S3.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
01/22/21
RE: PLAN1'-0"2'-0" (MIN.)
GEOFOAM BACKFILL
RE: PLAN
2" CLR.1'-6" MIN.RE: PLAN1'-0" 2'-0" (MIN.)
GEOFOAM BACKFILL
RE: PLAN1'-6" MIN. 2" CLR.3/4"3/4" 1'-3" 1'-1" 1'-8"1'-0"8"3/4"RE: PLAN1'-0"2"
CLR.10"2'-0"
1" MAX. OFFSET
(CENTERLINE OF COLUMN-
CENTERLINE OF PIER)4'-0" MIN.8"MIN.1'-6" MIN.8" MIN.3"MIN.9"1'-0"8" MIN.1 1/2"5" 1 1/2" 5"
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
EXTERIOR WALL WITH
SHEATHING
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"RE: PLAN
TOP OF
CONCRETE
FINISH FLOOR
RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(XXX'-XX")
[XXX'-XX"]
#5 AT 1'-4" X
2'-0"2'-0"
#5 AT 1'-4" VERTICAL
AND HORIZONTAL
(2)-#5 TOP AND BOTTOM
(5)-#5 CONT.
#5 AT 1'-4" X 2'-6"1'-2"
#5 AT 1'-4"
(XXX'-XX")
(5)-#5 CONT.
RE: PLAN
TOP OF
CONCRETE
EXTERIOR WALL WITH
SHEATHING
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
RE: PLAN
TOP OF
PLYWOOD
FLOOR SHEATHING
FINISH FLOOR
RE: ARCH.
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
FINISH FLOOR
RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(2)-#5 TOP AND BOTTOM
5/8" Ø X 2'-6" THREADED ROD
AT 2'-0"
5/8" Ø THREADED INSERT
AT 2'-0"#5 AT 1'-4" X
#5 AT 1'-4"2'-6"1'-2"
RE: PLAN
SLIP JOINT
SLAB-ON-GRADE
RE: PLAN
TOP OF
CONCRETE
(XXX'-XX")
{XXX'-XX"}
CONSTRICTION JOINT
ACCEPTABLE AT THIS
ELEVATION
[XXX'-XX"]
#5 AT 1'-0" VERTICAL
AND HORIZONTAL
(2)-#5 TOP AND BOTTOM
RE: PLAN
TOP OF PLYWOOD
FLOOR JOIST RE: PLAN WITH
SIMPSON ITS HANGER
#5 AT 1'-4" VERTICAL AND
HORIZONTAL EACH FACE
VARIES
TOP OF CONCRETE
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
#5 AT 1'-4"
(4)-#5 CONT.
2X TOP PLATE WITH 1/2" Ø X 10"
ANCHOR BOLTS AT 2'-6"
#5 X 4'-0" DOWEL AT 1'-0"
SECTION 4
3/4" = 1'-0"
TREATED 2X6 PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
FINISH FLOOR RE: ARCH.
8" SLAB-ON-GRADE
RE: PLAN
(2)-#5 TOP AND BOTTOM
#5 AT 1'-4" VERTICAL AND
HORIZONTAL
#5 AT 1'-4" X
2'-0"2'-0"
(XXX'-XX") #5 AT 1'-4"
(5)-#5
#5 AT 1'-4" X 2'-6" 1'-6"
WATERPROOFING
AND DRAINBOARD
RE: ARCH.
SLIP JOINT
PATIO RE: ARCH.
2X6 BEARING WALL
RE: PLAN
#5 AT 2'-0" X
SLIP JOINT
SLAB-ON-GRADE RE: PLAN
VARIES
TOP OF
CONCRETE2'-0"2'-0"
3" CONCRETE TOPPING
SLAB WITH 6X6 W2.1XW2.1
W.W.F. (RE: ARCH. FOR
CONTROL JOINT LAYOUT)
SLAB-ON-GRADE
RE: PLAN
RE: PLAN
(2)-#5 TOP AND BOTTOM
#5 AT MID-HEIGHT
#5 AT 1'-4" X
(ALTERNATE
HOOK)FULL HGT.8"
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN
10" Ø CONCRETE PIER WITH
28" Ø BIGFOOT FOOTING
SIMPSON ABA66
6X6 COLUMN (NOTCH FOR
(2)-2X10 BEARING) WITH
(2)-1/2" Ø THRU-BOLTS
#3 TIES AT TOP, MID-HEIGHT
AND BOTTOM
(4)-#5 X
FULL HGT.6"
3" STONE AND GROUT
RE: ARCH.
5" SLAB-ON-GRADE
RE: PLAN VERIFY WATERPROOFING,
DRAINBOARD AND TREAD/
RISER DIMENSIONS WITH
ARCHITECT.
#4 AT EACH NOSE
DRIVEWAY BY OTHERS
#5 AT 1'-0"
EACH WAY
RE: PLAN
TOP OF
CONCRETE
RE: PLAN
TOP OF CONCRETE
FOOTING RE: PLAN FOR SIZE
AND REINFORCING AT ELEVATOR
3" CONCRETE TOPPING SLAB
WITH 6X6 W2.1XW2.1 W.W.F.
(RE: ARCH. FOR CONTROL JOINT
LAYOUT)
SLAB-ON-GRADE
RE: PLAN
6"
HSS COLUMN RE: PLAN
1/2" X 8" X 8" EMBED
PLATE AT 2'-0"
CONCRETE WALL RE: 3/S3.2
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FOUNDATION
SECTIONS
S3.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
01/22/21
1'-0"
6 1/2"1 1/2"1 1/2"3" 3"3 1/2"
6"5 3/4"10"1'-0"5 3/4"6 1/4"3 1/2"
6" 1 1/2"CLR.1 1/2"
CLR.2"2 1/2" 2 1/2" 2 1/2"
10" 1 1/2"1 1/2"3/4"3"3/4"4"6" 2" 2" 4" 2"3/4"4 3/4"
6 1/2"
A
A
B
B
A
SECTION 20
3/4" = 1'-0"
SECTION 19
3/4" = 1'-0"
SECTION 18
3/4" = 1'-0"
SECTION 17
3/4" = 1'-0"
SECTION 15
3/4" = 1'-0"
SECTION 14
3/4" = 1'-0"
SECTION 13
3/4" = 1'-0"
SECTION 12
3/4" = 1'-0"
SECTION 11
3/4" = 1'-0"
SECTION 10
3/4" = 1'-0"
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
1/4
3/4" X 5 3/4" X 10 1/4"
END PLATE WITH (4)-
3/4" Ø BOLTS
3/4" END PLATE
(2)-1/2" Ø X 10" ANCHOR
BOLT AND NON-SHRINK
GROUT
STEEL BEAM RE: PLAN
3/8" X 2 1/2" HORIZONTAL
STIFFENER EACH SIDE OF WEB
(ALIGN WITH BOTTOM FLANGE
OF W10 BEAM)
FOUNDATION WALL
RE: 12/S4.1
14KIP BOLT PRETENSION
REQUIRED FOR END PLATE
CONNECTION BOLTS
1/4
BOTH
SIDES
2X TOP PLATE WITH 1/2" Ø THRU-
BOLTS AT 2'-0"
CJP
CJP TOP
AND BOTTOM
RE: PLAN
TOP OF
PLYWOOD
EXTERIOR WALL WITH
SHEATHING
LVL BEAM RE: PLAN
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. STONE AND
GROUT
FLOOR JOIST RE: PLAN
WITH SIMPSON IUT HANGER
RE: PLAN
TOP OF
PLYWOOD
RE: PLAN
TOP OF
PLYWOOD
EXTERIOR WALL WITH
SHEATHING
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. STONE AND
GROUT ON TAPERED
FLOOR JOIST RE: PLAN
WITH SIMPSON IUT HANGER
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN WITH 2X
TOP PLATE WITH 1/2" Ø BOLTS AT
2'-0" AND SOLID WEB PACK WITH
1/2" Ø THRU-BOLTS AT 1'-4"
STAGGER TOP AND BOTTOM
(2)-1/2" Ø X 10" ANCHOR BOLTS
WITH SHIM AND GROUT
STEEL BEAM RE: PLAN
3/8" WEB STIFFENER
(2)-1/2" Ø X 10" ANCHOR
BOLTS WITH SHIM AND
GROUT
SECTION A-A
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6" WITH SLOTTED HOLES
IN BOTTOM FLANGE OF BEAM
RE: PLAN
TOP OF
PLYWOOD
<XXX'-XX">
[XXX'-XX"]
<XXX'-XX">
(2)-L4X3 1/2X5 1/2" WITH
(2)-3/4" Ø BOLTS EACH LEG
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø THRU-
BOLTS AT 2'-0" STAGGER
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS
HANGER
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
(2)-1/2" Ø X 10" ANCHOR
BOLTS
FOUNDATION WALL
RE: XXXXX
8" CONCRETE SLAB RE: PLAN<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
[XXX'-XX"]
SECTION B-B
[XXX'-XX"]
SHIM AND GROUT
1/2" X 5" X 9" CAP PLATE
HSS COLUMN RE: PLAN
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT
2'-0" STAGGER
<XXX'-XX">
FLOOR SHEATHING
RE: PLAN
TOP OF PLYWOOD
3/8" WEB STIFFENER EACH SIDE
1/4 2"BOTH SIDES
1/2" X 5" X 9" CAP PLATE
HSS COLUMN RE: PLAN
(2)-L4X3 1/2X3/8 X 5 1/2" WITH
(2)-3/4" Ø BOLTS EACH LEG
3/8" END PLATE
3/8" WEB STIFFENER
STEEL BEAM RE: PLAN
1/2" X 6" X 1'-4" HORIZONTAL
STIFFENER WITH (2)-3/4" Ø
BOLTS SLOTTED FOR WEB
L4X4X1/4 X 5"
<XXX'-XX">
1/4 2"
<XXX'-XX">
1/4 BOTH SIDES
RE: PLAN
TOP OF
PLYWOOD
3/8" WEB STIFFENER
FLOOR SHEATHING
1/4 2" AT 6"BOTH SIDES
FLOOR SHEATHING
FLOOR JOIST RE: PLAN
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
#6 AT 1'-0" EACH FACE
RE: PLAN
TOP OF
PLYWOOD
[XXX'-XX"]
(4)-#6 TOP
SOLID BLOCKING BETWEEN
JOISTS
(XXX'-XX")
(6)-#6 BOTTOM
#3 STIRRUPS AT 1'-0"
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
HSS COLUMN RE: PLAN
3/8" X 4" X 8 1/2" SHEAR PLATE
WITH (3)-3/4" Ø BOLTS
CJP TOP AND
BOTTOM FLANGE
HSS COLUMN RE: PLAN
1/2" X 6" X 10" BASE PLATE
WITH (4)-3/4" Ø BOLTS
STEEL BEAM RE: PLAN
LVL BEAM RE: PLAN
HSS BEAM RE: PLAN
3/8" X 8" X 10" PLATE
WITH (4)-3/4" Ø THRU-BOLTS
1/4
BOTH
SIDES 2 1/2"4" SECTION 16
3/4" = 1'-0"
EXTERIOR WALL WITH
SHEATHING
FINISH FLOOR RE: ARCH.
FLOOR JOIST RE: PLAN
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0" AND
SOLID WEB BLOCKING WITH
(2)-1/2" Ø THRU-BOLTS AT 1'-4"
RE: PLAN
TOP OF
PLYWOOD
WATERPROOFING
AND DRAINBOARD
RE: ARCH.
3" MAX. TILE AND GROUT
ON TAPERED INSULATION
RE: ARCH.
DECK JOIST RE: PLAN
WITH SIMPSON LUS HANGER
1/2" Ø THREADED STUDS AT
2'-0" (STAGGER) FOR 2X NAILER
AT TOP, BOTTOM AND SIDES
OF FRAME MEMBERS
CJP
RE: PLAN FOR
FRAME SIZES
RE: PLAN FOR BEAM SIZES
HSS COLUMN RE: PLAN
3/8" X 4" X 8 1/2" SHEAR PLATE
WITH (3)-3/4" Ø BOLTS
3/16
STEEL BEAM RE: PLAN
WITH 2X TOP PLATE WITH
1/2" Ø THRU-BOLTS AT 2'-0"
STAGGER
3/8" X 4" X 6" SHEAR PLATE
WITH (2)-3/4" Ø BOLTS
3/4" X 8" X 1'-0" EMBED
PLATE WITH (4)-5/8" Ø
WITH 5" EMBED
<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
FINISH FLOOR RE: ARCH.
FLOOR SHEATHING
1/4
[XXX'-XX"]
PATIO RE: ARCH.
FOUNDATION WALL
RE: 7/S3.1
RE: PLAN
TOP OF
PLYWOOD
STEEL BEAM RE: PLAN WITH
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0"
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
<XXX'-XX">
RE: PLAN
TOP OF
PLYWOOD
FLOOR JOIST RE: PLAN
WITH SIMPSON ITS HANGER
FLOOR FINISH RE: ARCH.
FLOOR SHEATHING
LVL BEAM RE: PLAN
WITH (4)-3/4" Ø BOLTS
WEB BLOCKING AS
REQUIRED
[XXX'-XX"]
<XXX'-XX">
3" MAX. STONE AND GROUT
WATERPROOFING AND
DRAINBOARD RE: ARCH. ON
TAPERED INSULATION
3/4" DECK SHEATHING
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN
WALL BEYOND
FOUNDATION WALL RE: 12/S4.1
RE: PLAN
TOP OF
PLYWOOD
FLAT ROOF WATERPROOFING
AND DRAINBOARD RE: ARCH.
3" MAX. GRAVEL BALLAST
5/8" ROOF SHEATHING
ROOF JOIST
RE: PLAN
TREATED 2X6 WITH 1/2" Ø X 10"
ANCHOR BOLTS AT 2'-6"
WALL BEYOND
[XXX'-XX"]
INSULATION RE: ARCH.
C SPLICEL
.
.
.
.
.
.
.
.
.
.
.
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FLOOR FRAMING
SECTIONS
S4.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
01/22/21
3"3 1/4" 3" 1 1/2"4 1/2" 2"1 1/2"1 1/2" 3" 2 5/8" 2 7/8"
3" TYP.EQ.EQ. A A
SECTION 4
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
RE: PLAN
TOP OF DECKING
DECK JOIST RE: PLAN WITH
SIMPSON LUS HANGER
WOOD BEAM WITH CHANNEL
WITH (2)-1/2" Ø THRU-BOLTS
AT 1'-4"
2X DECKING RE: ARCH.
RE: PLAN
TOP OF
PLYWOOD
DECK JOIST RE: PLANSTEEL BEAM RE: PLAN WITH 1/2" Ø X 6"
H.A.S. AT 6"
3" MAX. STONE AND GROUT
RE: ARCH.
WATERPROOFING AND
DRAINBOARD RE: ARCH.
ON TAPERED INSULATION
8" CONCRETE WALL
WITH #5 AT 1'-4"
VERTICAL AND
HORIZONTAL
(2)-#5 TOP AND BOTTOM
HSS BEAM RE: PLAN WITH
1/4" END PLATE EACH END TYP.
HSS COLUMN RE: PLAN
3/8" X 3" X 1'-0"
WITH (3)-3/4" Ø BOLTS
1/4
FRAMING AT ELEVATOR
SECTION A-A
DECK FRAMING RE: PLAN
1/4" X 6" X 8" PLATE WITH
(2)-1/2" Ø THRU-BOLTS
HSS COLUMN RE: PLAN
WATERPROOFING AND
DRAINBOARD ON TAPERED
INSULATION RE: ARCH.
3" MAX. TILE AND GROUT
LVL BEAM RE: PLAN
3/8" X 5 1/2" X 6"
BEARING PLATE
ROOF JOIST RE: PLAN
WITH SIMPSON LUS
HANGER
LVL BEAM RE: PLAN
3" MAX GRAVEL BALLAST
WATERPROOFING AND
DRAINBOARD RE: ARCH.
SECTION 6
3/4" = 1'-0"
RE: PLAN
TOP OF
CONCRETE
FINISH FLOOR RE: ARCH.
SLAB-ON-GRADE RE: PLAN
#5 AT 2'-0" X 2'-0"2'-0"
FOUNDATION WALL
RE: 1/S3.2
DECK JOIST
RE: PLAN
TREATED 2X10 LEDGER
WITH 5/8" Ø EPOXY ANCHORS
WITH 5" EMBEDMENT AT 2'-8"
STAGGER TOP AND BOTTOM
TREATED 2X PLATE WITH
1/2" Ø X 10" ANCHOR BOLTS
AT 2'-6"
SECTION 7
1 1/2" = 1'-0"
SECTION 8
1 1/2" = 1'-0"
HSS COLUMN RE: PLAN
1/2" X 6" X 1'-0"
(2)-3/4" Ø BOLTS
STEEL BEAM RE: PLAN WITH 2X
TOP PLATE
3/8" STIFFENER ALIGN WITH
COLUMN ABOVE
HSS COLUMN RE: PLAN
1/4 6"
1/2" X 6" X 8" CAP PLATE WITH
(2)-3/4" Ø BOLTS
SHEAR WALL RE: PLAN
HOLD-DOWN RE: SCHEDULE
WITH 5/8" Ø THRU-BOLT
2X TOP PLATE WITH 1/2" Ø
THRU-BOLTS AT 2'-0"
STAGGER
STEEL BEAM RE: PLAN
SECTION 9
3/4" = 1'-0"
HSS COLUMN RE: PLAN
FOUNDATION WALL
RE: 7/S3.1
1/2" BASE PLATE WITH (4)-1/2" Ø
THREADED STUDS WELDED TO
EMBED PLATE
5/8" X 6" X 1'-6" EMBED PLATE
WITH (6)-#5 X 2'-0"
.
.
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
FLOOR FRAMING
SECTIONS
S4.21469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
01/22/21
2
12
2
12
2
12
2
12
EQUAL
(UNLESS NOTED ON PLAN) EQUAL
RE: ARCH.
8" 6"2"4" 4" A
A
SECTION 9
3/4" = 1'-0"
SECTION 8
3/4" = 1'-0"
SECTION 7
3/4" = 1'-0"
SECTION 6
3/4" = 1'-0"
SECTION 5
3/4" = 1'-0"
SECTION 3
3/4" = 1'-0"
SECTION 2
3/4" = 1'-0"
SECTION 1
3/4" = 1'-0"
LVL RE: PLAN
SIMPSON H3
EXTERIOR WALL WITH SHEATHING
SUB-FASCIA
RE: PLAN WITH (4)-10d NAILS
SOLID BLOCKING BETWEEN
JOISTS
SOLID BLOCKING BETWEEN
JOISTS
ROOF JOIST RE: PLAN
(2)-SDS25350 SCREWS
STEEL BEAM RE: PLAN WITH
(2)-2X6 BEVELED TOP PLATE
WITH 1/2" Ø THRU-BOLTS AT
2'-0"
ROOF SHEATHING
ROOF SHEATHING
SUB-FASCIA RE: PLAN
ROOF JOIST RE: PLAN
(2)-SDS25500 SCREWS
LSTA15 AT 4'-0"
LVL BEAM RE: PLAN
ROOF SHEATHING
SOLID WEB PACK WITH
1/2" Ø THRU-BOLTS AT
1'-4" STAGGER
STEEL BEAM RE: PLAN
WITH BEVELED TOP PLATE
WITH 1/2" Ø THRU-BOLTS
AT 2'-0"
ROOF JOIST RE: PLAN
WITH SIMPSON LSSU
HANGER
WEB BLOCKING AS REQUIRED
RE: MANUFACTURER
SECTION 4
3/4" = 1'-0"
ROOF SHEATHING
ROOF JOIST RE: PLAN
SOLID BLOCKING BETWEEN
JOISTS
EXTERIOR WALL WITH
SHEATHING(2)-SDS25500 SCREWS
EXTERIOR WALL WITH SHEATHING FLASHING AND WATERPROOFING
RE: ARCH.
ROOF SHEATHING
ROOF FRAMING RE: PLAN
STEEL BEAM RE: PLAN WITH
SOLID WEB PACK BLOCKING
WITH 1/2" Ø THRU-BOLTS
AT 1'-4" STAGGER AND 2X TOP
PLATE WITH 1/2" Ø THRU-BOLTS
AT 1'-4"
EXTERIOR WALL WITH SHEATHING FLASHING AND WATERPROOFING
RE: ARCH.
ROOF SHEATHING
ROOF FRAMING RE: PLAN
WITH SIMPSON IUS HANGER
AND WEB BLOCKING AS
REQUIRED
CONTINUOUS SHEATHING
ACROSS ROOF/PARAPET
(NO HORIZONTAL SEAMS)
LVL BEAM RE: PLAN
WINDOW RE:ARCH.ROOF JOIST RE: PLAN
WITH SIMPSON ITS HANGER
WATERPROOFING
AND DRAINAGE
RE: ARCH.
SIMPSON LSTA21
AT 2'-8"
3" MAX. GRAVEL
BALLAST
CJP
3/8" X 4" X 1'-2 1/2"
SHEAR PLATE WITH
(5)-3/4" Ø BOLTS
STEEL BEAM
RE: PLAN
CJP
1/4" 2" AT 4"
HSS BEAM RE: PLAN
HSS COLUMN RE: PLAN
CJP
BOTH
SIDES
CJP
SECTION A-A
SECTION 13
3/4" = 1'-0"
SECTION 12
3/4" = 1'-0"
SECTION 11
3/4" = 1'-0"
SECTION 10
3/4" = 1'-0"
STEEL BEAM RE: PLAN
3/8" X 4" X 11 1/2" SHEAR
PLATE WITH (4)-3/4" Ø BOLTS
HSS COLUMN RE: PLAN
3/16
CJP TOP AND
BOTTOM FLANGES
HSS COLUMN RE: PLAN
3/8" X 4" X 11 1/2" SHEAR
PLATE WITH (4)-3/4" Ø BOLTSSTEEL BEAM
RE: PLAN
1/2" X 6" X 6" MOMENT
PLATE TOP AND BOTTOM
1/4 6"
TOP AND BOTTOM
FLANGE
CJP TOP
AND BOTTOM
ROOF JOIST RE: PLAN
SOLID BLOCKING BETWEEN
JOISTS
EXTERIOR STUD WALL
WITH SHEATHING
WEB BLOCKING AS
REQUIRED
SIMPSON H3
WATERPROOFING AND
DRAINBOARD RE: ARCH.
3" MAX. GRAVEL
BALLAST
ROOF SHEATHING
1/4" X 3" X 10" PLATE WITH
(2)-1/2" Ø THRU-BOLTS
LVL BEAM RE: PLAN
HSS COLUMN RE: PLAN
1/4
.
.
.
.
.
.
.
.
.
. .
137 main street, suite G004
box 5055
edwards, colorado 81632
970.926.2622
snow@rkdarch.com
www.rkdarch.com
job # 12122
5/22/2020
ROOF FRAMING
SECTIONS
S5.11469 Greenhill CrtLot 11 Glen Lyon SubdivisionVail, COProject Status
development
Revisions
PERMIT 9/15/2020
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21
01/22/21