HomeMy WebLinkAboutB07-0143Community Development Department 75 South Frontage Road Vail, Colorado USA 81657 TOO OF VAR CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various ordinances of the town regulating building construction or use for the following: Name and description of project A New Single Family Residence Address of project: 4852 Meadow Lane Owner name and address: Meadow Lark Development Partners LLC IBC Edition: 2003 IBC Occupancy Group(s): R3 Type(s) of Construction: VB Permit Number(s): B07-0143 Occupant Load: NA Sprinkler System Y/N Type: 13 artin H eberle, Chief Building Official Date TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Job Address: 4852 MEADOW LN VAIL Location.....: 4852 MEADOW LANE Parcel No...: 210113104010 OWNER MEADOWLARK DEVELOPMENT PARTN05/16/2007 PO BOX 6605 TYLER TX 75711 ARCHITECT JOHN G. MARTIN, ARCHITECT LL05/16/2007 PO BOX 4701 EAGLE CO 81631 License: 0000001843 APPLICANT SINGLETRAK BUILDERS, INC. 05/16/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A CONTRACTOR SINGLETRAK BUILDERS, INC. 05/16/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A Permit B07-0143 Project PRJ07-0008 Status ISSUED Applied..: 05/16/2007 Issued . 06/21/2007 Expires.....: 07/06/2007 3\~k 1 Phone: 970-668-1200 Phone: 970-668-1200 Desciption: LOT 11-CONSTRUCTION OF ANEW DUPLEX Occupancy Type Factor Sq Feet Valuation RESIDENT/1 & 2 FAM ( ZONE 1 IA 115.72 8,458 $978,759.76 Totals... 8,458 $978,759.76* Number of Dwelling Units: 1 Town of Vail Adjusted Valuation: $978,759.76 Revision Valuation: $14,500.00 *+rr*******sr*+*r**********r*x«**********r*********t+**** FEE SUMMARY ****►*****a**r**+*x****************s*****s***+****s**** Building > $5,580.25 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $10,479.11 Plan Check $3,627.16 Recreation Fee------------ > $1,268.70 Additional Fees > $0.00 Investigation-> $0.00 TOTAL FEES > $10,479.11 Total Permit Fee-----------> $10,479.11 Will Call-----> $ 3 . 0 0 Payments > $10,479.11 BALANCE DUE--------- > $o.00 s*~*+r******~*****~*~►:**a*****r+*►***+******+**ra+*r►+•~e**a~***~*r**~~*s**~******~~**+~«a~r***a****»****s****+~+*~**s**:***sr*■+*ae+.**«•***r** Approvals: Item: 05100 BUILDING DEPARTMENT 06/14/2007 cgunion Action: COND 1) PROVIDE COMPLETE CONSTRUCTION DRAWINGS i INSPECTION REPORT FOR THE SOIL NAIL WALL REVIEWED AND APPROVED BY THE STRUCTURAL I PRIOR TO FOOTING INSPECTION. SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONST] 09/06/2007 cgunion Action: AP approved updated shoring plans 11/02/2007 jpiano Action: AP Changes to foundation approved with receipt soil nail drawings or written approval of as-built wall supporting footing Item: 05400 PLANNING DEPARTMENT 06/04/2007 RLF Action: AP 11/02/2007 RLF Action: Item: 05600 FIRE DEPARTMENT 05/17/2007 JJR Action: Submit shop drawings for sprinkle Item: 05500 PUBLIC WORKS 06/15/2007 gc Action: 06/20/2007 gc Action: AP Reviewed revisions on 11/1/07 AP See conditions. r and alarm systems. DN Provide same info required from B07-0142. AP 11/07/2007 gc Action: AP Reivions approved 11/7/07 Item: 05550 ENGINEERING CIVILS See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEP E 11T 479-2149 OR AT OUR OFFICE FROM 8:00 AM 4 PM. A" AA~ l k&cltla S NATURE OF OWNER OR CONTRA OR HI ELF AND OWNER CONDITIONS OF APPROVAL Permit B07-0143 as of 11-08-2007 Status: ISSUED Permit Type: NEW (SFR,P/S,DUP) PERMIT Applicant: SINGLETRAK BUILDERS, INC. Job Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Applied: 05/16/2007 Issued: 06/21/2007 Parcel No: 210113104010 CONDITIONS Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0008952 Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFES standards. Cond: CON0008953 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0009068 1) SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONSTRUCTION. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 34 (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED FOR. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC. TOWN OF VAIL, COLORADO Statement Statement Number: R070002483 Amount: $117.56 11/08/200703:35 PM Payment Method: Check Init: LC Notation: #1324/SINGLETRAK BUILDERS INC Permit No: B07-0143 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Total Fees: $10,479.11 This Payment: $117.56 Total ALL Pmts: $10,479.11 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 71.25 PF 00100003112300 PLAN CHECK FEES 46.31 0 A N NO A T MPLETE OR UNSIGN Buildm~ Permit ~ ~ ® C S 97q=~79~21~9..{lnspect~o~s) OViAO" WN REVISION TO TOWN OF VAIL BUILDING PERMIT Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 ***All Revision submittals must include the Field Set of approved plans. No further inspections will be performed until the revisions are approved. CONTRACTOR INFORMATION REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ . PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ For Parcel # Contact Eaale Countv Assessors Office at 970-328-8640 or visit www.eagle-county.com Parcel; 2 j0 j j j 0~ j 0 1 Job Name: *C7-2, MVJ L& Q 1 Job Address: AK?, LA~ 11 Legal Description Lot: Block: 1 1 Filing: Subdivision: Nv%PVvQtW D". 11 Address: Phone: g Address: Address: REASON FOR EVISIONS: [Work Class: New (A Addition( ) Remodel ( ) Repair ( ) Dl o ( ) Other ( ) FWork Type: Interior ( ) Exterior ( ) Both 1~ Does an EHU exist at this location: Yes( ) No~A Type of Bldg.: Single-family ( ) Two-family ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: = No. of Accommodation Units in this building: No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning No/Type of Fireplaces Proposed: Gas Appliances Gas Los Wood/Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes( ) No ( Does a Fire Sprinkler Sys %17 Ps ):,,r; wt I *************************************************FOR OFFICE USE ONLY****************************************?I II Date Received:; Permit Fee (10): PI_n'Ck Fee (80): Accepted By:" Permit Fee (11): PlanjCk Fee (81): - Outsourced Terms: ; . F:\cdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 / 7 1\.JYYIN 4/18/2007 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Permit B07-0143 Project PRJ07-0008 Job Address: 4852 MEADOW LN VAIL Location.....: 4852 MEADOW LANE Parcel No...: 210113104010 Status ISSUED Applied..: 05/16/2007 Issued. 06/21/2007 Expires.....: 07/06/2007 OWNER MEADOWLARK DEVELOPMENT PARTN05/16/2007 PO BOX 6605 TYLER TX 75711 ARCHITECT JOHN G. MARTIN, ARCHITECT LL05/16/2007 PO BOX 4701 EAGLE CO 81631 License: 0000001843 APPLICANT SINGLETRAK BUILDERS, INC. 05/16/2007 Phone: 970 -668-1200 PO BOX 4655 FRISCO CO 80443 License: 343-A CONTRACTOR SINGLETRAK BUILDERS, INC. 05/16/2007 Phone: 970- 668-1200 PO BOX 4655 FRISCO CO 80443 License: 343-A Desciption: LOT 11-CONSTRUCTION OF A NEW DUPLEX Occupancy Type Factor Sq Feet Valuation RESIDENT/1 & 2 FAM ( ZONE 1 IA 115.72 8,458 $978,759.76 Totals... 8,458 $978,759.76* Number of Dwelling Units: 1 Town of Vail Adjusted Valuation: $978,759.76 Revision Valuation: $0.00 FEE SUMMARY Building > $5,509.00 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $10,361.55 Plan Check $3,580.85 Recreation Fee------------ > $1,268.70 Additional Fees > $0.00 Investigation-> $0. 00 TOTAL FEES > $10,361.55 Total Permit Fee-----------> $10,361.55 Will Call-----> $ 3 . 0 0 Payments > $10,361.55 BALANCE DUE--------- > $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 06/14/2007 cgunion Action: COND 1) PROVIDE COMPLETE CONSTRUCTION DRAWINGS i SPECIAL INSPECTION REPORT FOR THE SOIL NAIL WALL REVIEWED AND APPROVED BY THE STRUCTURAL I PRIOR TO FOOTING INSPECTION. SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONSTI 09/06/2007 cgunion Action: AP approved updated shoring plans Item: 05400 PLANNING DEPARTMENT 06/04/2007 RLF Action: AP Item: 05600 FIRE DEPARTMENT 05/17/2007 JJR Action: AP See conditions. Submit shop drawings for sprinkler and alarm systems. Item: 05500 PUBLIC WORKS 06/15/2007 gc Action: DN Provide same info required from B07-0142. 06/20/2007 gc Action: AP Item: 05550 ENGINEERING CIVILS See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEP)4ONE AT 479-2149"OR AT OUR OFFICE FROM 8:00 AM 4 PM. SIGN TURE OF OWNER &U TRACTOR FOR HIMSELF AND OWNER CONDITIONS OF APPROVAL Permit B07-0143 as of 10-29-2007 Status: ISSUED Permit Type: NEW (SFR,P/S,DUP) PERMIT Applicant: SINGLETRAK BUILDERS, INC. Job Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Applied: 05/16/2007 Issued: 06/21/2007 Parcel No: 210113104010 CONDITIONS Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0008952 Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFES standards. Cond: CON0008953 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0009068 1) SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONSTRUCTION. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 34 (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED FOR. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC. I CATIO ILL N BE A C P E SCOMPLETE OR UNSIGNEDE,,l Building Permit # ff~~ 970=479,,,2149 (Ins#~e'~ipn) TOof REVISION TO TOWN OF VAIL BUILDING PERMIT Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 ***Ali Revision submittals must include the Field Set of approved plans. No further inspections will be preformed until the revisions are approved. NTRACTOR INFORMATION s: ATTENTION: JOE, JR, CHARLIEE"G, CHRIS Contractor Signatuke-,f)n A i ......M r•Tr- r%r•%11C II LICI MIA1 I IA-ri^KIC Cf1C Q1111 nimet PERMIT 11 ahnr P. Materials) REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ n_.._A- A........--- f%JW.-- „s 07f)_?9R_R9An nr vicif IAMIW PanlP.-rntjntv.com rV1 r-01 L.CI m VVIILQNL a_a Ir. vvu.a - - - - Job Name Job Address: ~2, Legal Description Lot: Block: IV+ Filing: Subdivision:' N Owners Name: Address: Phone: Arch itect/Designer: Address: Phone: Engineer: Address: REASON FOR REVISIONS: Work Class: New( ) Addition( ) Remodel( ) Repair ( ) Demo ( ) Ot r ) Work Type: Interior ( ) Exterior ( ) Both( ) Does an EHU exist at th ) 0( Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning No/Type e of Fire laces Proposed: Gas Appliances Gas Los Wood/Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes( ) No( ) Does a Fire Sprinkler System Exist: Yes( ) No( ) _._I.--- r•AI] ACLIl'C "CC AAII V*****~ Date Received: j Accepted By: c Permit Fee (10)v`- Permit Fee (11): Plan Ck Fee 80): Plan Ck Fee (81): _ I-/1..4ce~nrrnfl Tcrmc- F:\cdev\FORMS\Permits\Building\building_revision-4-18-2007.doc Page 1 of 1 4/18/2007 Jul 29 08 03:05p 903-939-2949 p.2 Eric Barnes Custom Builders i.1' M~dowtc~r~ July 29, 2008 City orvail Attention: Jennifer Lliuk RE: Building Pen-nits No. B07-0143 Dear Ms. F.liuk, I was contacted by our project manager in Vail regarding the changing over of the building permit to our company. The current building permit No. is B07-0143 at the address of 4852 Meadow Lane. Our builder's registration number is 26055. PleL. ~ ie, me know it 'l can help you in wiy other way. Shane Maullin's (project manager) number is 970-688-1267 if you require any other information regarding the site. 1 thank you for your efforts in making this transition possible. Regards Jeff Bourke Accounting Services 'tefP~~i:'ericl~~trn~scu5t~~mbuilders.coir Nov Pfi 07 10:25a Bedrock Post Office 970-859-7319 p.2 F GeoSolutions International, LL(! 95b Pmatacntte dnve Fruita, Colorado 81521 Phone: 970-985-1066 Fax: 970-314-%07 To: Singletrak Builders, Inc. (Contractor) James March P.O. Boa 4655 Frisco, CO 80443 Phone: 970-668-1200 Mobile: 970-389-8242 Fax: 970468-1201 From: Cameron Lobate, P.E. RE: Lot 11 and Lot 12 East Meadows Lane, Vail, Colorado.. Completion Proposal #2007-320 James, Q off-- ~ ~3 pt;y o*~ CXa 3 v Completion Letter November 2, 2007 1 i TOWN OF VAIL I have periodically observed and directed the installation of the permanent "f stabilization system at Lots 1 i and 12, East Meadows, Vail, Colorado. The design intent has been accomplished to my satisfaction, and will serve as both temporary shoring for the project as well as permanent stabilization. Monitoring by visual inspection of the stabilized highwalls should continue throughout the continued construction of the foundation elements of this project. Sincerely, Cameron Lo , P. . GeoSolutions International, LLC CAL: cal ~PpO UCE,I, f .S A. . 36 i~ 00 000 00010 ~~~FSS/ 0000 wn of Vail OFFICE COPY Nov Of 07 10:25a Bedrock Post Office 970-859-7319 p.3 Subject ~-cT 119 l e t µ ~t A~oU~ Project No. _ gM7- _S r,_ By , ► Checked By Task No. G'ow2~~ F~-~- - File No. Date - O Date Sheet of Nov O¢ 07 10:26a Bedrock Post Office 970-859-7319 p.4 Nm+. 02 07 02:37p GeoSolutions Int I, LLC 9703149607 P.1 Oct. 31. YUQJ 1U: RAM SINULLIKAII UUlL M IR6 no. a,42t r• Subject L.CT 1 I YZ El1T M>r Ai5 9205 Project No. Chedced BY BY -----•~=-tnl---- Task No. " File No, Date p•~~-d~ Gate Sheet of MR 1 L ct° t „ADO U A. • 3 :C SS~ONA- r G S J&K, INC. November 7, 2007 Greg Amsden AMS Development 500 South Frontage Road Vail, CO 81657 RE: Concrete Site Wall Design Residences at Lots I I and 12, Block 7, Bighorn Subdivision Filing 5 JK Job # EA07050 Mr. Greg Amsden: In response to the Town of Vail's request for calculations regarding the upper site concrete wall, I have enclosed a copy of the wall calculation. This wall is a non-load bearing wall required to step the back yard and minimize the exposure of the adjacent soil nail wall to six feet in accordance with the Town of Vail regulations. The soil nail wall serves as a pressure relief wall and eliminates soil pressure on the concrete wall in question. The footing for the concrete wall is to be placed on the bedrock bench at the elevations noted on the foundation plan. The void between the back of the concrete wall and the front of the soil nail wall is to be filled with GeoFoam, a product consisting of polystyrene blocks. These blocks support their own weight and do not transmit loads to the concrete wall. The soil nail retaining wall was designed and constructed by GeoSolutions International, LLC. A design booklet for the soil nail wall has been prepared with calculations and has been submitted to the Town for review under a separate submittal. Please contact me if you have any questions regarding this matter. Sincerely, W. Sean Kerrigan, P.E. Cc: John Martin - Architect James March - Single Trak Builders George Challberg -Town of Vail INTEGRITY FROM THE GROUND UP" P 970 328 6368 F 970 328 1035 POST OFFICE BOX 409 1286 CHAMBERS AVENUE, SUITE 200 EAGLE, COLORADO 81631 )K-INC.COM r ~o, EAD/705-0 l-0 5 It { lZ ME,&C0,64 LA JOHNSON, KUNKEL & ASSOCIATES, INC. SHEET No. ! OF l P.O. Box 409 Eagle, CO 81631 CALCULATED BY- , DATE (970) 328-6368 CHECKED BY DATE scA~ STS [Z.CL Lod' Go NG~ vJ1.4; l . lb Lrv~ I.oe.r~ _-.ir_ (Ea h~fK e I ~ X A4 5 pG ~ L L - Ig'Z.°) t ZtVn J Z~ PLC' Sd~~- PAS - r 21 2c~ !'LF ~~~'D psFao~ I's ' 47e ,~rrl1 ~ ' r4rn1 c~~ f A Harz, 5 S Con/T, -LZ MOmXT 204.1 Isin~k SJws)ZV iNdd dl TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Job Address: 4852 MEADOW LN VAIL Location.....: 4852 MEADOW LANE Parcel No...: 210113104010 OWNER MEADOWLARK DEVELOPMENT PARTN05/16/2007 PO BOX 6605 TYLER TX 75711 ARCHITECT JOHN G. MARTIN, ARCHITECT LL0.5/16/2007 PO BOX 4701 EAGLE CO 81631 License: C000001843 APPLICANT SINGLETRAK BUILDERS, INC. 05/16/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A CONTRACTOR SINGLETRAK BUILDERS, INC. 05/16/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A Permit B07-0143 Project PRJ07-0008 Status ISSUED Applied..: 05/16/2007 Issued . 06/21/2007 Expires.....: 12/18/2007 Phone: 970-668-1200 Phone: 970-668-1200 Desciption: LOT I I-CONSTRUCTION OF ANEW DUPLEX Occupancy Type Factor Sq Feet Valuation RESIDENT/1 & 2 FAM ( ZONE 1 IA 115.72 8,458 $978,759.76 Totals... 8,458 $978,759.76* Number of Dwelling Units: 1 Town of Vail Adjusted Valuation: $978,759.76 Revision Valuation: $0.00 FEE SUMMARY Building > $5,509.00 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $10,361.55 Plan Check $3 , 580. 85 Recreation Fee------------ > $1, 268. 70 Additional Fees > $0.00 Investigation-> $0.00 TOTAL FEES > $10,361.55 Total Permit Fee-----------> $10,361.55 Will Call-----> $ 3 . 0 0 Payments > $10,361.55 BALANCE DUE--------- > $0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 06/14/2007 cgunion Action: COND 1) PROVIDE COMPLETE CONSTRUCTION DRAWINGS i INSPECTION REPORT FOR THE SOIL NAIL WALL REVIEWED AND APPROVED BY THE STRUCTURAL ] PRIOR TO FOOTING INSPECTION. SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONST] Item: 05400 PLANNING DEPARTMENT 06/04/2007 RLF Action: AP Item: 05600 FIRE DEPARTMENT 05/17/2007 JJR Action: AP See conditions. Submit shop drawings for sprinkler and alarm systems. Item: 05500 PUBLIC WORKS 06/15/2007 gc Action: DN Provide same info required from B07-0142. 06/20/2007 gc Action: AP Item: 05550 ENGINEERING CIVILS See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFI ROM 8:00 AM 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER CONDITIONS OF APPROVAL Permit B07-0143 as of 06-21-2007 Status: ISSUED Permit Type: NEW (SFR,P/S,DUP) PERMIT Applicant: SINGLETRAK BUILDERS, INC. Job Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Applied: 05/16/2007 Issued: 06/21/2007 Parcel No: 210113104010 CONDITIONS Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0008952 Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFES standards. Cond: CON0008953 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0009068 1) PROVIDE COMPLETE CONSTRUCTION DRAWINGS AND SPECIAL INSPECTION REPORT FOR THE SOIL NAIL WALL REVIEWED AND APPROVED BY THE STRUCTURAL ENGINEER PRIOR TO FOOTING INSPECTION. SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONSTRUCTION. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 34 (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED FOR. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC. TOWN OF VAIL, COLORADO Statement Statement Number: R070001044 Amount: $6,961.55 06/21/200711:57 AM Payment Method: Check Init: DDG Notation: Meadowlark Devel. Partners LLC 1050 Permit No: B07-0143 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Total Fees: $10,361.55 This Payment: $6,961.55 Total ALL Pmts: $10,361.55 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 5,509.00 PF 00100003112300 PLAN CHECK FEES 180.85 RF 11100003112700 RECREATION FEES 1,268.70 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 TOWN OF VAIL, COLORADO Statement Statement Number: R070000727 Amount: $3,400.00 05/16/200710:48 AM Payment Method: Check Init: JS Notation: 1187/SINGLETRAK BUILDERS, INC. Permit No: B07-0143 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW IN VAIL Location: 4852 MEADOW LANE Total Fees: $8,865.56 This Payment: $3,400.00 Total ALL Pmts: $3,400.00 Balance: $5,465.56 ACCOUNT ITEM LIST: Account Code Description Current Pmts PF 00100003112300 PLAN CHECK FEES 3,400.00 71 1, 7F V ' I' t APPLICATION WILL NOT BE Af.' PTED IF INCOMPLETEib UNSIG i t # I YiAY 1 1 200' 7 Pr~ r Bu 1. g Permit # ' 2149 ns actions I ~ r ' WNOF WKl OF `AIL 75 S. Frontage R • O 1 Vail Colorado 816 Tvms~ TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! CONTRACTOR INFORMATION 11 rPnPrnl rnntrar•.tnr Town of Vail Req. No.: Contact Person and Phone #'s: Email address: (:;1M(p [8Qu Fax G t7(p~jg ~I nnanr% r E T A /AI I IATInAIC CnD 01111 nltdr DFRMIT 11 nhnr R Materials) BUILDING: $ ELECTRICAL: $Vd OTHER: $ PLUMBING: $ OW MECHANICAL: $ 4,0 00 0 -1 1 TOTAL: $ G j6 0 A_ nsr.- s n7n_12172-ORd/1 nr vicif 1nnnnn1 Pan1P-cnijntV-0017] rv► r"AI(.C~ tt vvuaa~.a a-w .c vvu..a Parcel 210 I N04-010 Job Name: r Or I~ ftnW I A* {r - - - - - - - Job Address: 4ya Nr"7'am L'kje Legal Description Lot: J Block: Filing: Subdivision: A *tt2 VA<<L Co Ph b AV ArJV ~6 11 r 01 wco V~ Ir7J~ A-1 -11 VXM L 26r2&2~ AVJ 60 IN Ph ne: . Detailed Ascription ofCCwork' ~ kI V ~ l\ Work Class: New ( Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( ) Work Type: Interior ( ) Exterior ( ) Both ( Does an EHU exist at this location: Yes ( ) No ) Type of Bldg.: Single-family ( ) Two-family (Multi-family ( ) Commercial ( ) Restaurant ( ) Other( No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning No/T e of Fireplaces Proposed: Gas A liances Gas Los Wood/Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes( ) No( ) ) Does a Fire Sprinkler System Exist: Yes( ) No( FOR OFFICE USE ONLY FDate Received: Received By: F:\cdev\FORMS\Permits\Building\buildi ng_permit_4-17-2007.DOC Page 1 of 7 04/17/2007 I WORK ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION s I have included the asbestostest and report with my building permit application Jq. V 0r signature date • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature OR date • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date 05f10/2007 16:22 9702485412 GRAND WEST KIA >JUDY PAGE 02/08 A & D Asbestos Testing and Consulting John R. Peterman P_O. Box 1230 Clifton, CO. 81520-1230 Cell 970-270-3689 Home Phone 970-464-5265 INSPECTION REPORT PREPARED FOR: Singletrak Builders, Inc. P.O. Box 4655 Frisco, CO. 80443 LOCATION: The Residence 4852 Meadow Lane Vail, CO. REPORT PREPARED BY: John R. Peterman Inspector Manager Certificate No. 6601 2 F- d dnp : {,n ,n n T Rew 05110/2007 16:22 9702485412 GRAND WEST KIA >JUDY PAGE 03/08 A & D Asbestos Testing and Consulting John R. Peterman Asbestos Testing, Project Design, and Consulting INTRODUCTION: On May 7th, 2007 an inspection/survey was conducted and 11 bulk samples were collected from: The Residence 4852 Meadow Lane Vail., CO. The purpose of the inspection/survey was to locate and sample suspected Asbestos containing materials that might be present in the house that is planned for demolition. The inspection was made, and the samples were collected by John R. Peterman, an A.H.E.R.A. and State of Colorado Certified Asbestos Inspector. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation far unseen conditions or stored items. All samples were analyzed by DCM Science Lab in Wheatridge, CO. This laboratory is deemed "Proficient" in the E.P.A.Quality Assurance (QA) program. for the determination of asbestos in bulk materials, and is accredited by the American Hygiene Association (ARA). SAMPLING PROTOCOL: A random sampling scheme was used to sample the suspect materials that were discovered. If during any future demolition or renovation work, suspect material is discovered that hasn't been sampled and would be disturbed, work should be halted until the material has been tested. 4.•d e4n7-l.n Jn nT CZ FP 1A 05/10/2007 16:22 9702485412 GRAND WEST KIA >JUDY PAGE 04/08 A & D Asbestos Testing and Consulting John R. Peterlman AshestosTesting, Prgject Design, and Consulting The Residence 4852 Meadow Lane Vail, CO. BUILDING DESCRI.PTION: The Residence at 4852 Meadow Lane is planned for demolition.. The building is a three-story, A-frame type, with a wood shake shingle roof. The soffits are exposed wood. The exterior walls are covered with wood siding, and brick. The interior walls are covered in sheetrock with a texture applied to it, and wood siding. The ceilings are covered in sheetrock with a spray-0n texture, and sheetrock like the walls. The floors are covered with carpet, 12"x12" floor tiles, and sheet vinyl flooring. The heating is provided by a fireplace, and a base board heating system. No suspect materials were visible on the heating system. NOTE: The .12"x12" floor tile was not sampled during this inspection at the request of the client. The light fixtures in the kitchen area should be disposed of as Asbestos waste. CONCLUSIONS & RECOMMENDATIONS: Laboratory analysis of the bulk samples indicates that Asbestos was detected in all of the bulk samples collected. The sheet vinyl flooring #006 contains Asbestos that is in excess of the Regulatory Limit (Greater than 1% Asbestos). The sheet vinyl will need to be removed as per Colo. Reg. #8 prior to disturbance of this material. The remaining samples contain Asbestos that is less than the Regulatory Limit. The Asbestos content of the positive samples was verified by the .required. Point Count Analysis. 4 c-A AT7:J.n in nT r,L-1J 05/10/2007 16:22 O U W d C J O d N to v d V C 41 O fq N ~ A Ma i 'm o~ 4 Q U 0 a rn 9702485412 W OWWMWt z zo Z, z z LWUI W UI z>. U. 7 3 ~ 3 7 W d d m 1--NF F~ ~ 3 i 3 3 ~ m d m~ 7 3 7 3 ~ 49 -14 -V x Ad r- O V Gi V tx m Ci 41 Z L Q c C c c Q Uf fp ~ t/l fJ? LL d d at d « m~ a~p~ ~C~c)UUU a W O a O O O C O CL CL CL w EEEEE~EWLu 2 w o o v o of Q. a CL CL CL 4 0 0 c.)QUfIaW00 0 N/ 2 1- O cc c m u m > o _ v E E Q . ~ 0 U O w to O O a C m- a CL 2 .w o IIW mO0 E y~ pC36~ amC~~ ~ o o C ro a o i Q U. 0 a~pi C C G C } 0 p ~ L 4 O O aC SCC~~ a 4 7=3 700 u14 D::i a m .-NNO~~Qsy ~n~cncooa~c~ m CS CS o °o c] Q a G z mm~~mmmmm~m -wj n. . ~ veQ~a~4~av~ GRAND WEST KIA >JUDY PAGE 05/08 --A AT:W:.6n in nT ReW 05/10/2007 16:22 9702485412 GRAND WEST KIA >JUDY PAGE 06/06 ssa~dCi pCGOcdNQOGOG m a N CLM96&a>.aoMMMM It m m U[iC=?UUUVUVUU 0 U .Z m C R J O V c{T N 'a N n L ~ e v 7 3 7 7 7 V v r. FF6F-FF 3 3 3 3>> a ~e x ~e sc ~e ~ rx Tc L"c Sc U O V p S1 GI Ci O 6! d ~ p C C= C C Z p ~ _ W co U) VJ N o v a► m m E o v v a V V C} ( 3 V rx Z a r. G C G C i c p $ p a>00000 a y ~ ; U a aML- . ; . _ % T . : 0 0 0 0 ` La U a.c. = O.aa U0 VUgnca f)fANV! 0 fm CP 4 a O C j v S o 0 z mcmmmto Mmin mmm NN NN NN N y NNN'N v v -w 'T Y b ~j aD drr ~Q v ruQ~q U V O o z } d va. z / 'aI dT7:4n in nT ReW 05/10/2007 16:22 V to 3 v m q CD U) C3 0 CC4 s h ~ ca ~ q D J CAD z O Q G~ QI 9702465412 W (s u- u- 12 p 0 W 0. t F ~ o°8o°S°oSoaOCS~g odc►dodcoa^o M wo 0 0 0 0 0 0 0 0 0 0 0 a ZZZZZZZZZWZ ~d 0 z 0 0 z 0 U 000000000-0 000000000 m 00000000C)R Lu O a tu I to fnfANNh~fndf U~(A~ m N LL 0 w a Q w ~v °ouTo~oISSCoQ=Qoo Z J M M O M M O M M M O M i3q"rll GRAND WEST KIA >JUDY D C 0 c v ~ W t m ~ N~q m Y PAGE 07/06 dT2:i O GO DI ReW 8 •d 05/10(2007 16:22 9702485412 GRAND WEST KIA >JUDY PAGE 08/08 V d G O v N V C N ~ 0 0 d ~ ~ J V ~Q H (Sr z 0 E c d a G O O c ~ o a O D. ~lO C a O C~ c~ Cho C } c ~ o ~ O. 'O O L E 3 z d a 00000000000 zzzzzzzzzzz 00000000000 J -1 J -1 J -1 -A _j -I -I J 00000000000 J J .J J J J J J J J .l zzxxxxxzxxx C3 CS(~t3C'it7L7(7C7t3C7 ====i'szzszz cA t!f U? ~ Ui rn fn tlf f!) to N W W tit ILI 111 4J 111 !11 W W W r s 0 " C3 9 ° O O OO 8 O 1- mmmmmma~mmmm N N N N N N N N N N N WIT g•d daa:.Io GO of Few tray ID 07 09:32a DCM Science Laboratory 303-463-9267 P•3 DCM SCIENCE LABORATORY, INC. 12421 W_ 49TH AVENUE, UNIT #6 WHEAT RIDGE, CO 80033 (303) 40-6270 DRAir BULK ASBESTOS ANALYSIS - POINT COUNT METHOD PAGE 1 OF 3 CLIENT: ANALYSIS DATE: 5-1 A&D ASBESTOS TESTING REPORTING DATE: 5-10-07 653 36 114 ROAD RECEIPT DATE: 5-9-07 PALISADE, CO 81526 CLIENT JOB NO.: RESIDENCE PROJECT TITLE: 4852 MEADOW LN- - VAIL DCMSL PROJECT: ADAT362 CROSS REFERENCE: ADA7360 PERCENTAGE COMPOSITION BY AREA/VOLUME DCM LAB NO.: -IR -2R -3R -4R -5R SAMPLE DATE: 5-7-D7 5-7-07 5-7-07 5-7-07 5-7-07 % OF TOTAL SAMPLE: 3.0°/, 4.01/6 4.0% 3.D% 3.0% CLIENT NO.., 4852-13-001 4852-13-002 4852-13-003 4852-B-004 4852-B-005 PART B PART B PART B PART B PART B ASBESTIFORM MINERAL, FIBERS: CHRYSOTILE 0.50% 0.500/0 1.00% 1.25% 1.00% AMOSITE ND ND ND ND ND CROCIDOLITE ND ND ND ND ND TREMOLITE-ACTINOLITE ND ND ND ND ND ANTHOPHYLLITE ND ND ND ND ND TOTAL ASBESTOS COUNTED 0,50% 0.501/0 1.00% 1.251/6 1.00% TOTAL ASBESTOS IN LAYER 0,500/0 0.50% 1.00% 1-25% 1,00% TOTAL ASBESTOS IN SAMPLE 0.02% 0.02% 0.04% 0.04% 0.03% NOTES: SAMPLES NO. IR AND 2R ARE WHITE AND TAN DRYWALL MUD. SAMPLES NO. 3R - 5R ARE WHITE DRYWALL N ND - NONE DETECTED TOTAL ASBESTOS COUNTED = TOTAL ASBESTOS IN LAYER = TOTAL ASBESTOS IN SAMPLE DEFINITIONS THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED AS A PERCENT. THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED EXPRESSED AS A PERCENT. THE PERCENT OF TOTAL SAMP LE (FROM PLM/SM ANALYSIS) TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN OTHER LAYERS). d2O:t O GO OT ReW DT'd May 10 07 09:32a DCM Science Laboratory 303-463-9267 p-4 A DCM SCIENCE LABORATORY, INC. 12421 W. 49TH A VENUE, UNIT #6 ~ WHEAT RIDGE, CO 80033 (303) 463-8270 BULK ASBESTOS ANALYSIS - POINT COUNT METHOD DRAFT PAGE 2 OF 3 CLIENT: ANALYSIS DATE: 5-0 A&D ASBESTOS TESTING REPORTING DATE: G53 36 1 r4 ROAD RECEIPT DATE: 5-9-07 PALISADE, CO 81526 CLIENT JOB NO.: RESIDENCE PROJECT TITLE: 4852 MEADOW LN. - VAIL DCMSL PROJECT: ADAT362 CROSS REFERENCE: ADAT360 PERCENTAGE COMPOSITION BY AREANOLUME DCM LAB NO.: -6R -7R -811 -9R -IOR SAMPLE DATE: 5-7-07 5-7.07 5-7-07 5-7-07 5-7-07 OF TOTAL SAMPLE: 80.0% 80.0% 80.0% 80.0% 85.0% CLIENT NO.: 4852-B-OD7 4852-B-008 4852-B-009 4852-B-010 4852-3-011 PART B PART B PART B PART B PART B ASBESTIFORM MINERAL FIBERS: CHRYSOTILE 0.25% 0.75% 1.D0% 0.75% 0.75% AMOSITE ND ND ND ND ND CROCIDOLITE ND ND ND ND ND TREMOLITE-ACTINOLITE ND ND ND ND NO ANTHOPHYLLITE ND ND ND NO NO TOTAL ASBESTOS COUNTED 0.25% 0.75% 1.000/0 0.75% D.75°/ TOTAL ASBESTOS IN LAYER 0.25% 0.75% 1.00% 0.75% 0.75% TOTAL ASBESTOS IN SAMPLE 0100/. 0.60% 0.80% 0,60% 0.64% NOTES: SAMPLE NO. 6R IS TAN FOAMY CEILING TEXTURE. SAMPLE NO. 7R IS WHITE FOAMY CEILING TEXTURE. SAMPLES NO. 8R - I OR ARE TAN FOAMY CEILI NG TEXTURE. ND - NONE DETECTED DEFINITIONS TOTAL ASBESTOS COUNTED = THE AMOUNT OF ASBESTOS PRESENT IN THE SAMPLE EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN LAYER = THE PERCENT OF SAMPLE REMAINING TIMES ASBESTOS COUNTED EXPRESSED AS A PERCENT. TOTAL ASBESTOS IN SAMPLE = THE PERCENT OF TOTAL SAMPLE (FROM PLMISM ANALYSIS) TIMES THE TOTAL ASBESTOS IN LAYER (IF NO ASBESTOS IN OTHER LAYERS). I I- Cl daa : ib0 GO o l Rew u, May OS 07 11:56a DCM Scien ce Laboratory 303-463-8267 p.2 ut y v~ o o g o c 0 0 0 0 o 0 0 0 0 c o 0 0 0 o c c o o u o 0 o c o o n c o 0 0 C p p pp O O 8 o 0 0 o O v o 0 0o 0 0 o O oo O o ° 0 0 2 0 0 Q E :E - OF ~ A E ~+rn ❑ o~no0 0~noo + : 0~?00 G o n 0000 o c c ' 0.000 ' 00 0 C c~ c. o a o o oc~ a o orn rn . c oa c o c o a o~ a v c ro a G z o j f z o . j Fy o 0 o c 0 0 0 0 ~ 0 0 0 0 0 o 0 0 0 0 0 o 0 0 o q c o 0 c o r o O Z O o C- 00 - o 00 - C. 0 _ C y a O U a ❑ o ^ o _ v _ a N 3 Q F o o o2 - w mLUSmG Z G Z Z Zz z Z Z ZZ 7 ZZ ^ Z A-A dA < i Q LU a) o p W W U F< y w u) u y Ow > ui y 009-o x ~LLI t o o O o < d ` = < a c s d c z O '•a ~ U O~ ti u l < U V o t ;n ~ 2 z x x LU F- U a Ici LUQ oa a zw W v <W WUw0 o a L: v U Z °n a % 0 w e e x$ g- e e g e o e qy~ o~ gz e C o w e o o yy S U .-4 M. 0 0 O C. 0 0 0 ^J. C O N 0 ~ C. ' ; 0 0 0 V 0 0 /V W N 1.1 Ci N1 Q N r M1 N e'f II 1 C . f'^ N OO Z c 3 z o ~ ca ~ z z y } L w y a W a < F ~ F ~ N ~ ~ ~ i ❑ z ❑ Z . ❑ .-7 ..i . ' v i r N 3 L:4 F ti 3 N 3 h 3 3¢< o z ' ° o c z zec z a Oz zmac Zaoa M 0 0-:4-a E- mo 1 ; 3 I l-~ I.. t ZZ F- . W F F 5 ! U 7 x z ¢ Y ~ Q T j S Q" j C S x; Z I r F- i F F 3 c. i F S r 3 3 O U , I C c~ U ❑ Q m Ci < Ci ❑ < O U a < C] U ❑ ¢ 3~ w ' r r ~ F a o 0 0 0 o c < rz n r r b ^ D `n N vi h F v i O CS °O F < C ~ G U x Cl Ld 'A IT e o $ 0 00 0 12 0 a l y @ O , ❑ m m p, W q td fA C] C ~o a. U ra ,Z l e v c c v v Z cn s. m I N ~ a v~ ~ J C < c nZ 21 'd dza=.0 GO OT Rew May 09 07 11:57a DCM Science Laboratory 303-463-8267 y O o O o 0 0 0 0 O 0 0 o o Q O C S C p 0 0 0 O C W ~ O U W ~ rn y I a Z o o a o o o: o h o oc+ o 0 o° a o v~ °o rn O o a oa ul x Z z } 0 0 oc 0 0 o0 o c 000 00 ~ c o C A C ~ F Y y W O H ..i C U : 6 7 m v z o Cl 1 .Q 0 o a F ; 2 8 y 1 o i z ,°o yz ~ w ~ 4 w v, CLn ❑n ❑r, o oo oQ n F"' d o Z o zo Z~ Z- Z .&d,oo~u~❑ Z2 ,A v, a Q a r w - N ao y w - - - r O C cG F- Q LLI O t7] U Q > N w.t La w O G O O a Z y L7 OmF C cn v'°" O O y L. y F O y Y r E-- < Z 5 Q G DSO W y0 . l ~ z n wC`L Qa CA 2 U s U U U u ik U tzi U w Q a V Z u.~ .:a Lti U ❑ ~U O aL ~ z V p h a dcX :a W > a° a o 0 0 0 < O F.~ 00 ov, 00 00 00 ~ U W C) N m rv~ W h rv F J W L.1 ~ V N N a U = ca d y C' t il F -1-1 t a w i ❑ s Z C w V s z`- F U F V W N 0 Q yO C v D ❑ ~ y < e a u v w w E5 w C Lz C-1 _1 F u X X O J o X F w F ~7 V F - C1 F U 0 c J z ~ z ? Lp ❑ V U F C F- F- U O a 4 oQ. w i 6 y< c G U ❑ w0 wm Fr wo F'z W~ F' u~•°_ L=z h a z o Z z ~ z o < c < ci d o ¢ m ¢ o z 'J a w I A p r7 J O A O n O h C , w y W Y c m o A 0 O 0 0 w F- '.l m ~ CI IN O 9 N F- ¢ `t f h N U v: z Q 4 v Q 0. ua m o _ < v A n Z p.3 ET'd J6a:bO GO OT Rew 41/k -1:7 l S~ LC Uk( Gl:lt~ ~G1 f G1 S ' 21,,'Lcuel t.~Q `t 1 t 5= t tv, s4- Le I c}~~xt ~ ~>I ~ r~ 1 t 2n~ (U~ v~► d = 521 c C',L~ F- 4 r IC d 4 3(e 4 ~ll I L~~ c 11 Elements of Glazing Performance 'T'ECHNICAL INFORMATION Sierra Pacific 0 A Division of X. Sierra Pacific Industries Sierra Pacific Windows offers the following high performance spectrally-selective glass from Cardinal. LoE2 -172 Glass All Climate, All Season Window Class The clear choice, no matter where you live. MUnlike many glass products on the market today, Cardinal LoE2-172 is the one clear choice. With patented coatings and superior energy ratings, LOE2-172 delivers the clearest, highest performing glass available today. Because LoE2-172 glass blocks most of the sun's damaging ultraviolet rays, it will help curtains, carpets, furniture and wall coverings stay beautiful for years to come. Window glass that can control the weather. Although windows provide beautiful views and wonderful natural light, they can also account for up to 30 percent of the annual energy consumed in a home. Cardinal LoE2-172 glass is designed to provide year-round savings and comfort by optimizing both the sun's heat and the home's heating and cooling systems. In the summer, LoE2-172 keeps the home cool and comfortable by rejecting the sun's heat and damaging rays. In the winter, LoE2-172 helps the home stay warm and cozy by reflecting heat back into the room. Think of it as invisible insulation. Cardinal's LoE2-172 blocks 84 percent of the sun's harmful ultraviolet rays and delivers a remarkable 96 percent performance improvement in winter nighttime insulation (R-value) compared to non-coated air- filled insulating glass. However, it is virtually invisible to the eye - just like looking through clear glass. In fact, LoE2-172 is the clearest, highest performing glass on the market; there's no haze or bluish cast to mar the view. LoE2-172 even outperforms the tinted glass often used in warm, sunny climates. You see out and the light shines in, with no heavy bronze or smoke-colored tints to darken the personality of the home. All around comfort, all year long. If you live in a climate controlled by heating and air conditioning, Cardinal LoE2-172 is the best available glazing option. It provides unhindered views, substantial savings on both heating and cooling bills and year-round comfort. In addition, many utility companies are now offering rebates for energy efficient window products like LoE2-172. • 7/2/2004 NOTE: Sierra Pacific Windows reserves the right to change specifications without notice. 25 R-VALUE I Salar Heat Shading I Visible Liaht PRODUCT GLAZING OPTION RES. NONRES. RES. NONRES. RES. NONRES. RES. NONRES. Clad CasMMOrench Casement/ Dualpane 0.55 0.54 1.82 1.85 0.55 0.54 55% 59% Eyebrow Casement (CC, CFC, CCE) LoE Argon 0.39 0.37 2.56 2.70 0.31 0.31 48% 51% Residential frame size: 24'x 60' LoE Air 0.42 0.40 2.38 2.50 0.31 0.31 48% 51% Nonresidential frame size: 30' x 60' Dualpane SOL w/bar 0.57 0.56 1.75 1.79 0.50 0.50 50% 52% LoE Argon SOL w/bar 0.38 0.36 2.63 2.78 0.28 0.28 44% 45% LoE Air SDL w/bar 0.41 0.40 2.44 2.50 0.28 0.28 44% 45% Printed Casement/ read Casement/ Dualpane 0.48 0,48 2.08 2.08 0.54 0.54 55% 59% Eyebrow Casement (CW, WFC, CWE) LoE Argon 0.32 0.31 3.13 3.23 0.26 0.28 47% 5011/0 Residential frame size: 24x 48' LoE Air 0.35 0.34 2.86 2.94 0.26 0.28 47% 50% Nonresidential frame size: 30' x 60' Clad Awning (AC) Residential frame size: 48' x 24' Dualpane LoE Argon 0.54 0.39 0.53 036 1.85 2.56 1.89 2.78 0.55 030 0.54 0.31 55% 48% 59% 51.% Nonresidential frame size: 40'x 40' LoE Air 0.42 0.42 2.38 2.38 0.30 0.31 48% 51% Dualpane SOL w/Sar 0.56 0.56 1.79 1.79 0.50 0.50 49% 54% LoE Argot SOL w/Bar 0.38 0.36 2.63 2.78 0.28 0.29 431/6 47% LoE Air SDL w/Bar 0.41 0.40 2.44 2.50 0.28 0.29 43% 47% Primed Awning (AW) Dualpane 0.48 0.48 2.08 2.08 0.54 0.54 55% 59% Residential frame size: 48' x 24' LoE Argon 0.32 0.31 3.13 3.23 0.30 0.31 48% 51% Nonresidential frame size: 40' x 40' LoE Air 0.35 0.34 2.86 2.94 0.30 0.31 48% 51% Clad Dalbte Hung (OCS) Dualpane 0.53 0.52 1.89 1.92 0.54 0.54 55% 59% Residential frame sae: 36' x 60' Dualpane w/Storm & Screen Combo. 0.35 0.35 2.86 2.86 0.48 0,47 50% 53% Nonresidential frame sae: 48' x 72' LoE Argon 0.37 0.35 2.70 2.86 0.26 0.28 47% 50% WE Argon w/Storm & Screen Combo. 0.26 0.24 3.85 4.17 0.28 0.30 43% 45% WE Air 0.40 0.38 2.50 2.63 0.26 0.28 47% 50% WE Air w/Stom & Screen Combo. 0.28 0.27 3.57 3.70 0.28 0.30 42% 45% Duaipane SDL w/Bar 0.54 0.54 1.85 1.85 0.49 0.49 49% 530/0 DoaW SDL w1k w/Storm & Screen Combo. LoE Argon SDL w/Bar 0.34 0.37 0.34 0.36 2.94 2.70 2.94 2.78 0.26 0.26 0.27 0.27 38% 38% 40% 40% Pritriad us" tpmg (OW) Dualpane 0.49 0.50 2.04 200 0.52 0.48 54% 58% Residential frame sae: 36x 60' Dualpane wlStorm & Screen Combo. 0.30 0.31 3.33 3.23 0.47 0.46 49% 52% Nonresidential frame size: 48' x 77 LoE Argon 0.33 0.32 3.03 3.13 0.25 0.27 46% 49% LoE Argon w/Storm & Screen Combo. 0.22 0.21 4.55 4.76 0.27 0.29 42% 44% LoE Air 0.37 0.35 2.70 2.86 0.25 0.27 46% 49% WE Air w/Storm & Screen Combo. 0.25 0.25 4.00 4.00 0.27 0.29 42% 44% Clad Glider (GC, GCP) Duaipane 0.53 0.53 1.89 1.89 0.54 0.54 55% 53% Residential frame sae: 60' x 36' Dualpane w/Storm & Screen Combo. 0.36 0.35 218 2.86 0.49 0.47 50% 53% Nonresidential frame size: 72x 48' LoE Argon 0.37 0.35 2.70 2.86 0.26 028 47% 500/0 OE Argon w/Storm & Screen Combo 0.27 0.25 3.70 4.00 0.28 0.30 43% 45% LoE Air 0.41 0.39 2.44 2.56 0.26 0.28 47% 47% LoE Air w/Storm & Screen Combo. 0.29 0.28 3.45 3.57 0.28 0.30 43% 45% Wired GDder (6111, GWP) Duaipane 0.50 0.50 2.00 2.00 0.53 0.54 55% 59% Residential frame size: 60'x 36' Duaipane w/Storm & Screen Combo. 0.30 0.31 3.33 3.23 0.48 0.47 51% 53% Nonresidential frame sae: 72x 48' LoE Argon 0.34 0.32 2.94 3.13 0.26 0.28 47% 50% WE Argon w/Storm & Screen Combo 0.22 0.21 4.55 4.76 0.28 0.29 43% 45% Dualpane LoE Air 0.37 0.36 2.70 2.78 0.26 0.28 47% 50% LoE Air w/Storm & Screen Combo. 0.22 0.21 4.55 4.76 0.28 0.29 43% 45% tiMNWI1 PD) Residential frame size: 38'x 82' Dualpane LoE Argon 0.47 0.33 2.13 3.03 0.49 0.21 .45 0.21 49% 33% 48% 32% WE Air 0.36 2.78 0.24 0.24 42% 40% Primed VWan13 Swbtging Deer (VM) Dualpane 0.48 2.08 Residential frame size: 38'x 82' LoE Argon 0.32 3.13 LoE Air 0.35 2.86 IDad fnm* Sw Doff (CFD) Dualpane 0.47 2.13 0.49 0.44 49% 48% Residential frame sae: 38'x 82' LoE Argon 0.33 3.03 0.24 0.24 42% 41% WE Air 0.36 2.78 0.24 0.24 42% 41% Printed French SO" Door (WFD) Dualpane 0.46 2.17 0.48 0.45 49% 4 % Residential frame size: 38' x 82' LoE Argon 0.32 3.13 0.27 0.22 41% 0 40% LoE Air 0.35 2.86 0.32 0.26 41% 40% Clad Oft Patio Deer (CPO) Dualpane 0.55 0.65 1.82 1.82 0.64 0.66 66% 65%° Residential frame size: 72"x 82' LoE Argon 0.35 0.85 2.86 2.86 0.31 0.31 56%° 55% Nonresidential frame size 72' x 96' LoE Air 0.38 0.38 2.63 263 0.31 0.31 56% 55% Primed Sliding Patio Door (LPO) Dualpane 0.51 0.51 1.96 1.96 0.63 0.59 66% 58% Residential frame sae: 72' x 82' LoE Argon 0.31 0.31 3.23 3.23 0.31 0.31 56% 50% Nonresidential frame size 72'x 96' WE Air 0.35 0.35 2.86 2.86 0.31 0.31 56%° 500/0 Clad Frond Slating Patio Deer (CFSD) Dualpane 0.52 0.49 1.92 2.04 0.52 0.49 52% 52% Residential frame size: 72'x 82' LoE Argon 0.36 0.35 2.78 2.86 0.26 0.27 44% 44% Nonresidential frame sae 72' x 96' LoE Air 0.39 0.38 2.56 2.63 0.26 0.27 44% 44 0 PrW Frd Sliding Patio Doer WWI Dualpane 0.49 0.49 2.04 2.04 0.51 0.49 52% 520/0 Residential frame size: 72° x 82' LoE Argon 0.32 0.32 3.13 3.13 0.25 0.26 44% 44% Nonresidential frame size 72'x96' LoE Air 0.35 0.35 2.86 2.86 0.25 0.26 44% 44% U-Factor data published in this catalog was calculated in accordance wim the Nauonar renestraaon mating t)uocri rest procedure Nrtiu iuu. NFRC ratings are determined for a fixed set of environmental conditions and specific product saes and may not be appropriate for directly determining seasonal energy performance. The inverse of the U-Factor is calculated and reported as the R-Value. 'GLAZING OPTION NOTES: Only the more popular glazing options have been fisted. There are many options and possible combinations of options that may adjust the U-Factor of a product. Some of these options include: internal grid, SOL spacer bar, glass tinting, breather tube, LoE, LoE Sun 145, Argon gas, combo storm and screen, energy panel, and ADL cut-lites. AN dualpane LoE options are Argon gas filled (95% Argon, 5% air) with the exception being high aftitude applications (over 5000 feet), which have an air filled cavity with a breather tube installed. This table is to be used as a reference guide only, and not as a direct determination on how your speMc product will be NFRC rated or labeled. Consult with Semco at 1-800-933-2206 for more detailed U-Factor data or specific NFRC U-factor labeling information. i n n C7 M CA C03 O M C02 O CD M law, Serra Pftift Windows Glazing T C YPe typendows asement Wi Sash CPA U-factor SHGC V, CR 0C SG/WD 001 0.79 0.48 0.49 11 SG/NR SG/WD 001 0.79 0.53 0.54 11 WC WNR 001 0.80 0.48 0.49 11 001 0.80 0 53 0 54 WC SG WC IG/WD . , 11 001 0.80 0.58 0.60 11 WC IG/NR 001 0.43 0.43 0.45 45 001 0.43 0 48 0 50 WC WC IG IG/WD/LE . . 45 001 0.43 0.52 0.55 45 001 WC IG/NR/LE 0.32 0.23 039 56 001 0.32 0.26 0 44 56 WC DC IG/LE IDL . 001 0.32 0.28 0.48 56 DC Il)t/U 001 0.45 0.43 0.45 45 001 0 36 DC ML/EE . 0.23 0.39 56 001 WC IG/WD/EE 036 0.15 0.22 56 001 0.32 0.15 0 22 56 WC WC IG/NR/EE IG/EE . 001 032 0.16 0.24 56 001 032 0.18 0.27 56 Casement Half Round Windows DCH DCH SG/WD SG/NR 001 0.79 0.48 0.49 11 001 0 79 0 53 CH CH SG/WD . . 0.54 11 001 0.80 0.48 0.49 11 CH SG/NR SG 001 0.80 0.53 0.54 11 CH IC/WD 001 0.80 0.58 0.60 11 001 0.43 0 43 0 45 CH CH IG IG NR . . 45 001 0.43 0.48 0.50 45 CH IGjWD/LE 001 0.43 0.52 0.55 45 001 0.32 0.23 0 39 56 CH CH IG/NR/LE IG/LE . 001 0.32 0.26 0.44 56 001 0.32 0 28 0 DCH DCH IDL IDL/LE . .48 56 001 0.45 0.43 0.45 45 DCH IDL/EE 001 036 0.23 039 56 CH 1G/WD EE 001 0.36 0.15 0.22 56 CH / IG/NR EE 001 0.32 0.15 0.22 56 CH / IG/EE 001 0.32 0.16 0.24 56 001 0 32 0 18 Radiu s Casement win . . 0.27 56 dows DRC DRC SG/WD SG/NR 001 0.79 0.48 0.49 11 RC SG/WD 001 0.79 0.53 0.54 11 001 0.80 0.48 0 49 11 RC RC SG/NR SG . 001 0.80 0.53 0.54 11 RC IG/WD 001 0.80 0.58 0.60 11 001 0.43 0 43 0 45 C IG/NR . . 45 001 0.43 0.48 0.50 45 C RC IG IG 001 0.43 0.52 0.55 45 RC /WD/LE IG/NR 001 0.32 0.23 0.39 56 RC /LE IG/LE 001 032 0.26 0.44 56 001 0.32 0.28 0 48 56 DRC DRC IDL ML/LE . 001 0.45 0.43 0.45 45 001 DRC TWEE 0.36 0.23 039 56 001 0.36 0.15 0 22 56 RC RC IG/WD/EE IG/NR EE . 001 0.32 0.15 0.22 56 RC / IG/EE 001 0.32 0.16 0.24 56 001 0 32 0 18 French Casement Wind . . 0.27 56 ows DFC DFC SGJWD SG/NR 001 0.79 0.48 0.49 11 001 0 79 0 53 FC FC SG/WD . . 0.54 11 DOI 0.80 0.48 0.49 11 FC SG/NR SG 001 0.80 0.53 0.54 11 FC IG/WD 001 0.80 0.58 0.60 11 001 0 43 0 43 FC FC 1G/NR . . 0.45 45 001 0.43 0.48 0.50 45 FC IG IG/WD LE 001 0.43 0.52 0.55 45 FC / IG/NR LE 001 032 0.23 039 56 FC / 1G/LE 001 032 0,26 0.44 56 001 0.32 0 28 0 48 DFC DFC IDL MULE . . 56 001 0.45 0.43 0.45 45 DFC ML/EE 001 036 0.23 039 56 001 0.36 0.15 0 22 56 FC PC IG/W1+D/EE IG/NR E . 001 032 0.15 0.22 56 FC / E 1G/EE 001 0.32 0.16 0.24 56 001 032 0 18 0 27 . . 56 sedona Casement Windows SC SC SG/WD SG/NR 001 0.80 0.48 0.49 11 SC SG 001 0.80 0.53 0.54 11 SC IG/WD 001 0.80 0.58 0.60 11 001 0 43 0 43 SC SC IC/NR . . 0.45 45 001 0.43 0.48 0.50 45 SC IG IG/WD/LE 001 0.43 0.52 0.55 45 001 0.32 0,23 039 56 SC SC 1G/NR/LE MILE 001 0.32 0.26 0.44 56 SC IG/WD/EE 001 032 0.28 0.48 56 001 0.32 0.15 0 22 56 SC C IG/NR/EE . 001 0.32 0.16 0.24 56 IG/EE 001 032 0.18 0.27 S6 Thermal Performance Data uPdated: 10-4-05 Woad Casement Window Wood Casement Window Single glaze Clear Wide grid bar Wood Casement Window Single glaze Clear Narrow grid bar Wood Casement Window Single glaze Clear Wide grid bar Wood Casement Window Single glaze Clear Narrow grid bar Woad Casement Window S Single glaze Clear Wood Casement Window Insulated lass Clear 9 Wide grid bar Wood Casement Window Insulated glass Clear Narrow grid bar Wood Casement Window Insulated glass Clear Wood Casement Window Insulated glass LoE2 Wide grid bar Woad Casement Window Insulated glass LoE2 Narrow grid bar Woad Casement Window Insulated glass LoE2 WWOOd Casement Window Wood C Insulated glass Clear Wide grid bar Insulated glass LOE2 Wid id asement Window Woad Casement Window e gr bar Insulated glass EE EE 1 140 Wide grid bar Wood Casement Window Insulated glass EE 140 Wide grid bar Woad Casement Window Insulated glass EE 140 Narrow grid bar Insulated glass EE 140 Wood Casement Wood Casement Half Round Window Half Round Window Single glaze Clear Wide grid bar asement Wood Casement alf Round Window Single glaze Clear Narrow g rid bar Single glaze Clear Wide r wg bar Wood Casement Half Round Window Half Round Window Single 9~e Clear Narrow grid bar Wood Casement Wood Casement Half Round Window Simile glaze Clear Insulated glass Clear Wide grid bar Wood Casement Half Raid Window Half Rood Window Iri glass Nairrow bai ~ed Wo od Casement WOW Casement alf Round Window g lass Cl ear lrh Insulated glass LoE2 Wide grid bar Wood Casement H Half Round Window alf Round Window Insulated glass LoE2 Narrow grid bar Wood Casement Wood Casement Half Round Window Insulate glass IM Insulated LoE2 glass C IM Wide grid bar Wood Casement Half Round Widow Half Round Widow Insulated glass LaE2 Wide grid liar WWI Casement Wood Casement Half Round Window Insulated glass EE 140 Wide grid bar Insulated glass EE 140 Wide grid bar wood Casement Half Raul Window Half Round Window Insulated glass EE 140 Narrow grid bar Insulated glass EE 140 W Radius Ca od W Raditis sement Widow Case t W Single glaze Clear Wide grid bar Wald Radius men indow Casem t w Single glaze Clear Narrow grid bar Woad Radius en indow Ca Single glaze Clear Wide gW bar Wood Radius sement Window Cas W Single glaze Clear Narrow grid bar Wald Rates ement indow Ca Single 9L- Clear Wald Radius sement win'dow Casem t W i Insulated glass Clow Wide grid bar Wad Radius en Casement Wi d Insulate glass Clear Narrow grid bar Wood Radius n ow C Insulated glass Clear Ward Radius asement Window Ca Insulated glass LoE2 Wide grid bar Wood Raduu sement window Case t Insulated glass WE2 Narrow grid bar Wood Radius men Window Ca Insulated gds Lou Wood Radius Window Case t W Insulated glass Clear Wide grid bar Wood Radius men indow Case t Lo E2 Insulated glass Wide grid bar Wood Radius men Window Ca EE 1 Insulated glass EE 140 Wide grid bar Wood Res sement Window Ca Insulated glass EE 140 wide grid bar Wood Radius sement Window Case t W Insulaited glass EE 140 Narrow grid bar men indow Insulated glass EE 140 Wood French Wo od French Casement Window C Single glaze Clear Wide grid bar WOW French asement Window C Single glaze Clear Narrow grid bar Wood Frer ich asement Window Cas Single glaze Clear Wide grid bar wood Frer ement window Casem t Wi Single glaze Clear Narrow grid bar Wand French en ndow Single glaze Clear C Wood French C asement Window as Insulated glass Clear grid bar Wig Wood French C ement Window a Insulated glass ear Narrow grid bar WOW French C sement Window as Cl Insulated glaiss Wood French C ement Window ase t W Insulated glass LoE2 Wide grid bar Wood French C men wdow as t Insulated glass LoE2 Narrow grid bar Wood French C emen Window Insulated glass LoE2 Wood French asement Window Insulated glass Clear Wide grid bar Wood French C Window a Insulated glass LoE2 Wide grid bar Wood French C sement as W E E 1 Insulated glass EE 140 Wide grid bar Wood French C ement indow asem t W Insulated EE 140 Wicle grid bar ~ g Wo od French C en rdow as W In sulated g la ss EE 140 Narrow grid bar ement indow Insulated glass EE 140 Wood Sedona Wood Sedona Ca Ca sement Widow Sri* glaze Clear wide grid bar Woad Sedona C sement Window asem t W Single glaze Clear Narrow grid bar Wood Sedona C en indow Single glaze Clear a Wood Sedona Ca sement Window s t W glass Clear Wide grid ba Wood Sedans Ca emen indow s d Insulated glass Clear Narrow Wood Sedona Ca ement WKKIOW Clear ed glass Wood Sedona C sement Window Insula E2 Wide "bar mss LO a Wood Ca sement Window Insulated glass LoE2 Narrow grid bar Wood Sedalia Ca sement Window Insulated glass LoE2 Wood Sedalia Ca sement Window Insulated glass EE 140 Wide grid bar Wood Sedona Ca sement Window se t Intsubted glass EE 140 Narrow grid bar men Window In sulated glass EE 140 Page t of 22 Glazing er Door Sidelights (narrow stifes) G/WD 047 0.77 0.42 0.43 12 Wood Patio Slider Door Sid~te Single glaze Clear Wide grid bar G/NR 047 0.75 0.47 0.49 12 Wood Patio Slider Door Sidelite Single glaze Clear Narrow grid bar SG/WD, 047 0.77 0.42 0.43 12 Wood Patio Slider Door Sideite Single daze Clear Wide grid bar r G/NR 047 0.77 0.47 0.49 12 Wood Patio Slide Door Sideite Single glaze Clear Narrow grid bar G 047 0.77 0.53 0.55 12 Wood Patio Sly Door Sideite Single gaze Clear 1G,/WD 047 0.44 0.38 039 45 Wood Patio Sider Door Sideite Insulated Mass Clear Wide grid bar GJNR 047 0.44 0.43 0.45 45 Wood Patio Slider Door Suleike Insulated glass Clear Narrow grid bar pSS G 047 0.44 0.48 0.50 45 Wood Patio Slider Door Sidelite Insulated glass Clear PSS IG/WD/LE 047 0.34 0.21 0.34 58 Woad Patio Slider Door Sideite Insulated glass LoE2 Wide grid bar PSS IGJNRJLE 047 0.34 0.23 0.39 58 Wood Patio Slider Door Sideite Insulated glass LoE2 Narrow grid bar PSS IgLE 047 034 0.26 0.44 58 Wood Patio Slider Door Sidelite Insulated glass LoE2 PS5 IG/WD/EE 047 0.34 0.13 0.19 57 Wood Patio Slider Door Sdeite Insulated glass EE 140 Wide grid bar PS5 IG/NRJEE 047 0.34 0.15 0.22 S7 Wood Patio Slider Door Sidelde Insulated glass EE 140 Narrow grid bar PSS IG/EE 047 034 0.16 0.24 57 Wood Patio Slider Door Sideite Insulated glass EE 140 DPSS IDL 047 0.46 0.38 0.39 45 Wood Patio Slider Door Sdeite Insulated glass Gear Wide grid bar DPSS IDL/LE 047 037 0.21 0.34 57 Wood Pates Slider Door SideAe Insulated glass LoE2 Wide grid bar DPSS IDLJEE 047 0.38 0.13 0.19 57 Wood Patio Sider Door SkleGte Insulated glass EE 140 Wide grid bar Patio Slider Door Transoms (narrow stiles) DPST SGJWD 049 0.85 0.48 0.49 12 Wood Patio Siklar Door Transom Single glaze Clear Wide grid bar DPST SG/NR 049 0.87 0.S4 0.55 12 Wood Patio Skier Door Transom Single glaze Gear Narrow grid bar PST SG/WD 049 0.88 0.48 0.49 12 Wood Patio Sider Doan Transom Slagle glaze Clear Wide grid bar PST SG/NR 049 0.88 0.54 0.55 12 Wood Patio SWw Door Transom Slagle glaze Clear Narrow grid bar PST SG 049 0.88 0.59 0.62 12 Wood Patio Slims Door Transom Single glaze Clear PST IGJWD 049 0.45 0.44 0.45 45 Wood Patio Slider Door Transom Insulated glass Clear Wide grid bar PST IGJNR 049 0.45 0.48 0.51 45 Wood Patio Slider Door Transom Insulated glass Gear Narrow grid bar PST IG 049 0.45 0.54 0.57 45 Wood PailO Sider Door Transom Iawlated glass Clear PST IG/WD/LE 049 0.33 0.24 0.40 55 Wood Patio Slider Door Transom Insulated glass LoE2 Wide grid bar PST IG/NRJLE 049 0.33 0.26 0.44 55 Wood Patio Slider Door Transom Insulated glass LoE2 Narrow grid bar PST IG/LE 049 0.33 0.29 0.50 55 Wood Patio Slider Door Transom Insulated glass LoE2 PST IG/WD/EE 049 0.33 0.15 0.22 55 Wood Patio Slider Door Transom Insulated glass EE 140 Wide grid bar PST IG/NRJEE 049 033 0.17 0.25 55 Wood Patio Slider Door Transom Insulated glass EE 140 Narrow grid bar PST IGJEE 049 0.33 0.18 0.28 55 Wood Patio Slider Door Transom Insiiated glass EE 140 DPST IDL 049 0.46 0.44 0.45 45 Wood Patio Slider Dow Transom Insulated glass Clear Wide grid bar DPST MILE 049 036 0.24 0.40 55 Wood Patio Slider Door Transom Insulated glass LoE2 Wide grid bar DPST IDL/EE 049 0.37 0.15 0.22 55 Wood Patio Slider Door Transom Insulated glass EE 140 Wide grid bar Inswin DID g Doors SG/WD 009 0.75 038 0.39 12 Wood Inswing Door Single gaze Gear Wide grid bar DID SG/NR 009 0.75 0.45 0.46 12 Wood inswing Door Slagle gaze Clear Narrow grid bar ID SG/WD 009 0.72 0.38 0.39 12 Wood Inswing Door Single glaze Clear Wide grid bar ID SGJNR 009 0.74 0.45 0.46 12 Wood Inswing Door Single glaze Clear Narrow grid bar ID SG 099 0.75 0.52 8.54 12 Wood Inswing Door Single glaze Char ID 1G/WD 0D9 0.44 0.35 0.36 46 Wood Inswing Door insulated glass Clear Wide grid bar ID 1G/NR OD9 0.44 0.41 0.42 46 Wood Inswing Door Insulated glass Gear Narrow grid bar ID IG OD9 0.44 0.47 0.49 46 Wood Inswing Door Insulated glass Gear rid bar s LoE2 Wide l I t d l ID IG/WDJLE 009 0.33 0.19 031 58 Wood Inswing Door g g nsu e as a TD IGJNR/LE 009 033 012 037 58 Wood Inswing Door hmAted yiass LoE2 Narrow grid bar ,D IGJLE 009 033 0.25 0.43 58 Wood Inswirg Door Insulated glass LoE2 w~Ip IG/WDJEE 009 0.33 0.12 0.17 58 Wuxi Inswing Door Insulated glass EE 140 Wide grid bar ID IG/NRJEE 009 0.33 0.16 014 58 Wood Inswing Door Insulated glass EE 140 Narrow grid bar ID IG/EE 009 0.33 0.16 3 0.24 0 36 58 46 Wood Inswing Door Door Wood Iasaia Insulated glass EE 140 Insulated 96" Clear Wide grid bar DID DID IDL IDLJLE 009 009 0.46 0.38 5 0. 0.19 . 0.31 56 g Wood Inswing Door Insulated glass LoE2 Wide grid bar DID IDL/EE 009 0.38 0.12 0.17 56 Wood Inswing Door Insulated glass EE 140 Wide grid bar Radius Inswing Doors DRID SGJWD 009 0.75 0.38 0.39 12 Wood Radius Inswing Door Single glaze Clear Wide grid bar DRID SG/NR 0D9 0.75 0.45 0.46 12 Wood Radius Inswing Door Single gaze Clear Narrow grid bar RID SGJWD 009 0.72 038 0.39 12 Wood Radius Inswing Door' Single glaze Clear Wide grid char RID SG/NR 009 0.74 0.45 0.46 12 Wood Radius Inswing Door Single glaze Clear Narrow grid bar RID SG 009 0.75 0.52 0.54 12 Wood Radius inswing Door Single gaze Clear RID IG/WD 009 0.44 0.35 036 46 Wood Radius inswing Door Insulated glass Clear Wide grid bar RID IG/NR 009 0.44 0.41 0.42 46 Wood Radius Inswing Door Insulated glass Clear Narrow grid bar RID IG 009 0.44 0.47 0.49 46 Wood Radius Inswing Door Insulated glass Clear RID IG/WD/LE 009 033 0.19 031 58 Wood Radius Inswing Door Insulated glass LoE2 Wide grid bar RID IG/NRJLE 0D9 0.33 0.22 0.37 58 Wood Radius Inswing Door Insulated glass LoE2 Marrow grid bar RID IGJLE 009 0.33 0.25 0.43 58 Wood Radius Inswing Door Insulated glass LOE2 RID IG/WD/EE 009 0.33 0.12 0.17 58 Wood Radius Inswing Door Insulated glass EE 140 Wide grid bar RID IG/NR/EE 009 0.33 0.16 0.24 58 Wood Radius Inswing Door insulated glass EE 140 Narrow grid bar RID IG/EE 009 0.33 0.16 0.24 58 Wood Radix Inswing Door Insulated glass EE 140 DRID IDL 009 0.46 0.35 0.36 46 Wood Radius Inswing Door Insulated glass Gear Wide grid bar DRiD IDL/LE 009 0.38 0.19 0.31 56 Wood Radius Inswing Door Insulated glass LoE2 Wide grid bar DRID IDLJEE 009 038 0.12 0.17 56 Wood Radius Inswing Door Insulated glass EE 140 Wide grid bar Inswi DLS ng Door Sidelights SG/WD 010 0.75 0.40 0.41 12 Wood Inswing Door Scieft Single.' gaze Clear Wide grid bar DS SGJNR 010 0.75 0.47 0.48 12 Wood Inswing Door Sidette Single gaze clear Narrow grid bar i5 SG/WD 010 0.74 0.40 0.41 12 Wood Inswing Door Sdeite Single glaze Clear Wide grid bar is SGJNR 010 0.75 0.47 0.48 12 Wood Inswing Door Sideite Single glaze Cleat' Narrow grid bar is SG 010 0.75 0.54 056 12 Wood Irrsanring Door Sideite Single glaze Clear is IG/WD 010 0.44 0.36 0.38 45 Wood Inswing Door Sdeite Insulated Sass Clear Wide grid bar is IG/NR 010 0.41 0.43 0.44 45 Wood Inswing Door Sidelite Insulated glass Clear Narrow grid bar is IG 010 0.44 0.49 0.51 45 Wood Inswing Door Sideiite Insulated glass Clear is IGJWD/LE 010 033 0.20 0.33 58 Wood Inswing Door Sdelite Insulated glass LoE2 Wide grid bar i5 IG/NR/LE 010 033 0.23 0.39 58 Wood Inswing Door Sidelite Insulated glass LoE2 Narrow grid bar 35 IG/LE 016 0.33 0.26 0.45 58 Wood Inswing Door Sdeite insulalied glass LoE2 is IG/WDJEE 010 033 0.13 0.18 57 Wood Inswing Door Sdelite Insulated glass EE 140 Wide grid blr is IG/NR/EE 010 033 0.15 0.22 57 Wood Inswing Door Sideite Insulated glass EE 140 Narrow grid bar is IG/EE 010 033 0.17 0.25 57 Wood Inswing Door Sideite Insulated glass EE 140 aIS IDL 010 0.45 0.36 038 45 Wood Inswing Door Sideite Insulated glass Clear Wide grid bar S `I IDL/LE 010 0.37 030 033 57 Wood Irsnwing Door Sidelite Insulated glass LOU Wide grid bar A ; IDL IEE 010 0.37 0.13 0.18 57 Wood Inswing Door Sidelite Insulated glass EE 140 Wide grid bar Page 11 of 22 Design Review Board ACTION FORM A Department of Community Development T 0 M f onffrVA I' 75 South Frontage Road, Vail, Colorado 81657 te1:970.479.2139 fax: 970.479.2452 "rrc a ftT web: www.vailgov.com Project Name: MEADOWLARK NEW PRIMARY SECONDARY UNIT DRB Number: DRB070033 Project Description: Participants: FINAL APPROVAL FOR NEW CONSTRUCTION OF A PRIMARY SECONDARY UNIT OWNER MEADOWLARK DEVELOPMENT PARTN01/29/2007 PO BOX 6605 TYLER TX 75711 APPLICANT JOHN G. MARTIN, ARCHITECT LL01/29/2007 PO BOX 4701 EAGLE CO 81631 License: 0000001843 ARCHITECT JOHN G. MARTIN, ARCHITECT LL01/29/2007 PO BOX 4701 EAGLE CO 81631 License: 0000001843 Project Address: 4852 MEADOW LN VAIL Location: 4852/4856 MEADOW LANE Legal Description: Lot: 11 Block: 7 Subdivision: BIGHORN 5TH ADDITION Parcel Number: 2101-131-0401-0 Comments: SEE CONDITIONS BOARD/STAFF ACTION Motion By: Dantas Action: APPROVED Second By: Dunning Vote: 3-0-0 Date of Approval: 03/21/2007 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Entry: 02/13/2007 By: DRhoades Action: COND Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFES standards. Entry: 02/13/2007 By: DRhoac Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Entry: 03/21/2007 By: 1. The applicant shall revise all grading and site plans to ensure that grade does not exceed 2:1. 2. The applicant shall work with the Fire Department to resolve all remaining concerns. 3. The applicant shall return to the DRB for review and approval of trim paint colors before submittal of application for building permits. Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond:201 DRB approval shall not become valid for 20 days following the date of approval. Cond:202 Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is commenced and is diligently pursued toward completion. Cond:113 All development applications submitted to the Town after the effective date of Ordinance 26, Series 2006 shall be subject to the pending employee housing regulations in whatever form they are finally adopted; provided, however, that if the Town fails to adopt the pending employee housing regulations by April 15, 2007, this Ordinance shall not apply to such development applications. Planner: RACHEL FRIEDE DRB Fee Paid: $650.00 LJ REScheck Software Version 4.0.1 Compliance Certificate Project Title: Meadows Lot 11 Duplex Report Date: 05102/07 Data filename: C:\Program Files\Check\REScheck\lot 11.rck Energy Code: 2003 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 23% Heating Degree Days: 9248 Construction Site: 4852 Meadow Lane (Lot 11, Block 7, Bighorn 5th) Vail, CO 81657 Owner/Agent: Greg Amsden AMS Development 500 S Frontage Rd Su 112 Vail, CO 81657 970-476-8610 amsden@vail.net Designer/Contractor: John Martin John G Martin, Architect, LLC PO Box 4701 Eagle, CO 81631 970-328-0592 john.martin@centurytel.net Ceiling 1: Flat Ceiling or Scissor Truss: asU oo.U - Ceiling 2: Cathedral Ceiling (no attic): 2104 38.0 0.0 57 Wail 1: Wood Frame, 16" o.c.: 1418 21.0 0.0 66 Window 1: Wood Frame:Double Pane with Low-E: 125 0.360 45 95 0.500 48 Door 1: Solid: 40 0.360 14 Door 2: Glass: " 2078 21.0 0.0 81 o.c.: Wall 2: Wood Frame, 16 360 0 190 Window 2: Wood Frame:Double Pane with Low-E: . 529 136 0.360 49 Door 3: Glass: " 2060 21.0 0.0 92 o.c.: Wall 3: Wood Frame, 16 360 0 130 Window 3: Wood Frame:Double Pane with Low-E: . 362 87 0.360 31 Door 4: Glass: Basement Wall 1: Solid Concrete or Masonry: 1688 11.0 0.0 88 Wan height 10.0' Depth below grade: 10.0' Insulation depth: 10.0' 76 Floor 1: Slab-On-Grade:Heated: 112 11.0 Insulation depth: 4.0' 24 Floor 2: All-Wood Joist/Truss:Over Unconditioned Space: 915 38.0 0.0 Boiler 1: Other (Except Gas-Fired Steam): 92 AFUE osed building design described here is consistent with the building plans, specifications, Th t and other e prop : Compliance Statemen calculations submitted with the permit application. The proposed building has been designed to meet the 2003 IECC requirements in REScheck Version 4.0.1 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. 4,ki?,T, rJ 4'4>J G- .1 ~ 3 -0 7 - Name - Title Signature Date Meadows Lot 11 Duplex Page 1 of 5 ~ln r. . . , c N j Date: 05/02/07 REScheck Software Version 4.0.1 Inspection Checklist Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 cavity insulation L;ommerns: ❑ Ceiling 2: Cathedral Ceiling (no attic), R-38..0 cavity insulation Comments: Above-Grade Wails: ❑ Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 3: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Basement Walls: ❑ Basement Wall 1: Solid concrete or masonry, 10.0' ht 110.01 bg / 10.0' insul, R-11.0 cavity insulation Comments: Windows: ❑ Window 1: Wood Frame:Double Pane with Low-E, U-factor. 0.360 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2: Wood Frame:Double Pane with Low-E, U-factor: 0.360 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3: Wood Frame:Double Pane with Low-E. U-factor. 0.360 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1: Solid, U-factor. 0.500 Comments: ❑ Door 2: Glass, U-factor 0.360 Comments: ❑ Door 3: Glass, U-factor. 0.360 Comments: ❑ Door 4: Glass, U-factor: 0.360 Comments: Floors: Meadows Lot 11 Duplex Page 2 of 5 ❑ Floor 1: Slab-On-Grade:Heated, 4.0' insulation depth, R-11.0 continuous insulation Comments: Slab insulation extends down from the top of the slab to at least 4.0 ft. OR down to at least the bottom of the slab then horizontally for a total distance of 4.0 ft. Exterior insulation has a rigid, opaque, weather-resistant protective covering that covers the exposed (above-grade) insulation and extends at least 6 in. below grade. ❑ Floor 2: All-Wood Joistlfruss:Over Unconditioned Space, R-38.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Boiler 1: Other (Except Gas-Fired Steam): 92 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rafted, fixtures are installed with a 3" clearance from insulation. Skylights: ❑ Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: ❑ Installed on the warm4n- winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency are dearly marked on the building plans or specifications. ❑ Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: ❑ Supply ducts in unconditioned attics or outside the building are insulated to R-11. ❑ Retum duds in unconditioned attics or outside the building are insulated to R-6. ❑ Supply ducts in unconditioned spaces are insulated to R-11. ❑ Return ducts in unconditioned spaces (except basements) are insulated to R-2. Insulation is not required on return ducts in basements. ❑ Where exterior walls are used as plenums, the wall is insulated to R-11. Duct Construction: ❑ Dud connections to flanges of air distribution system equipment are sealed and mechanically fastened. ❑ All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on duds operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: ❑ Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: El Circulating hot water pipes are insulated to the levels in Table 1. Meadows Lot 11 Duplex Page 3 of 5 Swimming Pools: LI All heated swimming pools have an ontoff heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time dock. Heating and Cooling Piping Insulation: Ll HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Meadows Lot 11 Duplex Page 4 of 5 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Saes Non-Circulating Runouts Circulating Mains and Runouts Heated Water ' Up to 1" Up to 1.25" 1.5' to 2.0" Over 2" F) Temperature ( 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Saes Piping System Types Fluid Temp. . Range("F) 2' Runouts 1" and Less _ 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressurerremperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 106-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Meadows Lot 11 Duplex Page 5 of 5 k~ a ~I ~I r' m m, rI r I I 0 I I ( I i II I( I II I ~I I I I ° Fol II m O Z v m m r D r r R F-01 0 I , I a~ v~ CI m' r) rI r , ( , I~ I° II II I ( II II I I , 00 00 op T r m rn r Z m n O Z v m m r 'D z v r m m r Z 0 0 -o n z N TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Job Address: 4852 MEADOW LN VAIL Location.....: 4852 MEADOW LANE Parcel No...: 210113104010 OWNER MEADOWLARK DEVELOPMENT PARTN 05/16/2007 PO BOX 6605 TYLER TX 75711 CONTRACTOR ERIC BARNES BUILDERS COLORAD 08/05/2008 120 W. 5TH STREET, SUITE 210 TYLER TEXAS 75701 License: 365-A ARCHITECT JOHN G. MARTIN, ARCHITECT LL 05/16/2007 PO BOX 4701 EAGLE CO 81631 License: 0000001843 APPLICANT SINGLETRAK BUILDERS, INC. 05/16/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A Permit B07-0143 Project PRJ07-0008 Status . . . : ISSUED Applied..: 05/16/2007 Issued . 06/21/2007 Expires.....: 07/06/2007 Phone: (903) 581-4100 Phone: 970-668-1200 Desciption: LOT I I-CONSTRUCTION OF ANEW DUPLEX Occupancy Type Factor Sq Feet Valuation RESIDENT/1 & 2 FAM ( ZONE 1 IA 115.72 8,458 $978,759.76 Totals... 8,458 $988,259.76* Number of Dwelling Units: 1 Town of Vail Adjusted Valuation: $988,259.76 Revision Valuation: $14,500.00 ssaaasssssaa*+**ssasass*+**+►*►**+ss*****sss+►****+** FEE SUMMARY *****saasa*aa*aasasa*asasa***as**.asasa:*.*sasaaassssasa Building > $5,619.70 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $10,874 .21 Plan Check $3,652.81 Recreation Fee------------ > $1,268 . 70 Additional Fees > $0.00 Investigation-> $0.00 TOTAL FEES > $10, 874 .21 Total Permit Fee-----------> $10,874.21 Will Call-----> $3 . 0 0 Payments > $10, 874.21 BALANCE DUE--------- > $0.00 ssa~+**+»**********sss****.**+.**~******+*+*~sas***sass****saaasasassasasas~+ssasaass~**sssssaa*assasasa*asassa~*+***+*asasa«**asaas******sa+*~~: Approvals: Item: 05100 BUILDING DEPARTMENT 06/14/2007 cgunion Action: COND 1) PROVIDE COMPLETE CONSTRUCTION DRAWINGS i INSPECTION REPORT FOR THE SOIL NAIL WALL REVIEWED AND APPROVED BY THE STRUCTURAL I PRIOR TO FOOTING INSPECTION. SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONST] 09/06/2007 cgunion Action: AP approved updated shoring plans 11/02/2007 jpiano Action: AP Changes to foundation approved with receipt soil nail drawings or written approval of as-built wall supporting footing 06/13/2008 cgunion Action: AP APPROVED REVISED ARCHITECTURAL AND STRUCTU] SHEETS DATED 3/31/08 AND 4/1/08 Item: 05400 PLANNING DEPARTMENT 06/04/2007 RLF Action: AP 11/02/2007 RLF Action: AP Reviewed revisions on 11/1/07 06/13/2008 RLF Action: AP Approved revisions dated 3/31/08 and 4/1/0 Item: 05600 FIRE DEPARTMENT 05/17/2007 JJR Action: AP See conditions. Submit shop drawings for sprinkler and alarm systems. Item: 05500 PUBLIC WORKS 06/15/2007 gc Action: DN Provide same info required from B07-0142. 06/20/2007 gc Action: AP 11/07/2007 gc Action: AP Reivions approved 11/7/07 06/25/2008 cdelles Action: CR Sent comments to architect 01/09/2009 cdelles Action: AP Approved retaining wall revisions DRB080086 See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN/'~DVANC~ BY TELy rNE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM 4 PM. r'! f// r SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER CONDITIONS OF APPROVAL Permit B07-0143 as of 01-13-2009 Status: ISSUED Permit Type: NEW (SFR,P/S,DUP) PERMIT Applicant: SINGLETRAK BUILDERS, INC. Job Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Applied: 05/16/2007 Issued: 06/21/2007 Parcel No: 210113104010 CONDITIONS Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0008952 Fire sprinkler system required and shall comply with NFPA 13R(2002) and VFES standards. Cond: CON0008953 Monitored fire alarm system required and shall comply with NFPA 72(2002) and VFES standards. Cond: CON0009068 1) SPECIAL INSPECTION REQURIED FOR SOIL NAIL WALL CONSTRUCTION. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 34 (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED FOR. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC. TOWN OF VAIL, COLORADO Statement Statement Number: R090000036 Amount: $395.10 01/13/200912:16 PM Payment Method:Credit Crd Init: SAB Notation: MC-ERIC BARNES CUSTOME BUILDERS Permit No: B07-0143 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: 4852 MEADOW LANE Total Fees: $10,874.21 This Payment: $395.10 Total ALL Pmts: $10,874.21 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 39.45 PF 00100003112300 PLAN CHECK FEES 355.65 0 TO W N 0t ViAPPLICATION WILL NOT BE CJEOD IF INCOMPLETE OR UNSIGNED Building Permit th H3 970-479-2149 (Inspections) REVI N O OWN OF VAIL BUILDING PERMIT Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 ***All Revision submittals must include the Field Set of approved plans. No further inspections will be performed until the revisions are approved. C 3/a CONTRACTOR INFORMATION Ge-neral Contractor: Town of Vail Reg. No.: e Contact and Phone #'s: ATTENTION: JOE, JR, CHARLIE, REG, CHRIS Contrac 0 S)g /~i d. 4 Y k 4 atre: t Y t y `'J COMPLETE REVISION.R FVni I IATInNC Fr-1R RI III nlAl/r CS=DeAIT It Q_ ne..~,._:..~..~ REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ 77 7_7 For Parcel # Contact Eaale Cnunty d csPCCnr_c r) irp of Q7n_49R_R1qdn nr iiicif lnnenni o~n►o_1+.,,,.~f„ Rarcel`# Job Name:`'` Job Address: Legal Description Lot: r I Block: [Filing: t Subdivision fi i _ R - t, _ Owners Name: Address'? ei = Phone: ~I Architect/.Desi ner: Addres t7 j 1 ; [Phone:, Engineer: Address: Phone: - -f z REASON FOR REVISIONS: - . 1 _ Work Class: New Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( ) Work Type: Interior ( ) Exterior ( ) Both `.J Does an EHU exist at this location: Yes( ) No( ) Type of Bldg.: Single-family ( ) Two-family Multi-family ( ) Commercial( ) Restaurant( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning No/Type of Fireplaces Proposed: Gas Appliances Gas Los Wood/Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes( ) No Does a Fire Sprinkler System Exist: Yes( ) No ) *************************************************FOR OFFICE USE ONI Y********************************************** Date Received: Permit Fee (110): PlarrCk Fee' (80): Accepted By: Permit Fee (11): Plan Ck Fee (81)`. Outsourced Terms: Z,e', (~,-W 6"; )~~S 1 D V 1( e (s l t C l U n F:\cdev\FO R MS\Pe rm its\Bu i Iding\building_revision 18-2007.doc Page 1 of 1 4/18/2007 Design Review Board ACTION FORM TOWN Y Od5 %UNiFY [)ESELtlPMW Department of Community Development 75 South Frontage Road, Vail, Colorado 61657 te1:970.479.2139 fax: 970.479.2452 Web: www.vailgov.com Project Name: MEADOWLARK-NEW DECK DRB Number: DRB080086 Project Description: Participants: NEW DECK OWNER MEADOWLARK DEVELOPMENT PARTN 04/03/2008 PO BOX 6605 TYLER TX 75711 APPLICANT JOHN G. MARTIN, ARCHITECT LL 04/03/2008 PO BOX 4701 EAGLE CO 81631 License: 0000001843 ARCHITECT JOHN G. MARTIN, ARCHITECT LL 04/03/2008 PO BOX 4701 EAGLE CO 81631 License: 0000001843 Project Address: 4852 MEADOW LN VAIL 4852 MEADOW LANE Location: Legal Description: Lot: 11 Block: 7 Subdivision: BIGHORN 5TH ADDITION Parcel Number: 2101-131-0401-0 Comments: BOARD/STAFF ACTION Motion By: Action: STAFFAPP Second By: Vote: Date of Approval: 05/22/2008 Conditions: Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 (PLAN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Planner: RACHEL FRIEDE DRB Fee Paid: $20.00 Record Nninber: 1 1191 lit Ie APCD Representative 5~ PARTY WALL AGREEMENT AND DECLARATION OF COVENANTS, CONDITIONS AND RESERVATIONS FOR LOTS 11 A AND I IB, A RESUBDIVISION OF LOT 11, BLOCK 7, BIGHORN 5TH ADDITION TOWN OF VAIL, COUNTY OF EAGLE, STATE OF COLORADO 1. RECITALS Meadowlark Development Partners, LLC ("Declarant") is the Owner in fee simple of the real property situate in the Town of Vail, County of Eagle, State of Colorado, described as a Resubdivision of Lot 11, Bock 7, Bighorn 5th Addition. Lot 11 is a duplex lot. Declarant has constructed on said Lot I1 certain improvements, intended for use and occupancy as residential dwelling Units and which consist of two dwelling Units to be designated hereafter as "Lot 11 A" and "Lot i 1 B" or collectively as "sots". Said Lot 11 has been subdivided into Lot 11 A which shall contain 4852 Meadow Lane East Half and may be designated as such herein, and Lot 1113, which shall contain 4852 Meadow Lane West Half and may be designated as such herein. II. DECLARATION Declarant does hereby publish and declare that the following terms, covenants, conditions, easements, restrictions, uses, reservations, limitations and obligations shall be deemed to run with the land described herein, shall be a burden and a benefit to Declarant, their personal representatives, heirs, successors and assigns, and to any person acquiring or owning an interest in the real property which is described herein, and improvements built thereon, their grantees, personal representatives, heirs, successors and assigns. 1. Definitions Unless the context shall expressly provide otherwise, the following terms shall have the following meanings: (a) "The Properties" shall mean all of the real estate legally described as Lots 11 A and 11 B, and also known as 4852 Meadow Lane East Half and 4852 Meadow Lane West Half respectively, a resubdivision of Lot 11, Block 7, Bighorn 5th Addition, Town of Vail, Eagle County, Colorado, according to the Final Plat Map thereof recorded in Book , Page Reception Number R200709528 Map 4-13-07 of the records of the Clerk and Recorder of Eagle County, Colorado. (b) "Lot" or "Parcel" means Lot 11A and 11B as shown on the Map together with all easements, encumbrances, appurtenances, and improvements, including the Units. Gordon/Party Wall Agreement and Declaration of Covenants 7/20/2009 (c) "Duplex" or "Building" shall mean the structure containing (2) contiguous dwelling Units (i.e. each dwelling being one-half of a duplex) constructed upon the Lots. (d) "Unit" shall mean any one of the (2) two dwellings comprising the "Duplex" or "Building" constructed upon the Lots pursuant to the Map, including the Lots. (e) "Common Access Easement" shall mean any such non-exclusive, reciprocal easement and right of way for ingress, and egress, appurtenant to each Lot, for the use of each owner, over, across and through that part of the other Owner's Lot, as indicated on the Map. (f) "Owner" shall mean a person, persons, firm, corporation, partnership or association, other legal entity, or any combination thereof, owning an interest in the Properties. (g) "Map" shall mean the Final Plat of the Properties prepared by , depicting and locating with specificity thereon the Lots, Units and other improvements, the easements and setbacks, such land and improvements being hereby submitted to this Declaration. Such Map shall be recorded in the office of the Eagle County Clerk and Recorder together with the recordation of this Declaration. (h) "Assessment' 'means any periodic or one time charge to cover the cost of any expense or charge that becomes due and owing by virtue of this declaration. 2. DESCRIPTION AND RESERVATION. Every Contract of Sale, Deed, Lease, Mortgage, Trust, Deed, Will or other instrument may legally describe a Unit or real property interest therein as follows: Lots 11A or 11B (as the case may be), according to the recorded Final Plat Map thereof and according to the Party Wall Agreement and Declaration of Covenants, Conditions and Restrictions for Lot 11A and 11B, a resubdivision of Lot 11, Block 7, Bighorn 5th Addition, Town of Vail, recorded in Book at Page , as Reception No. R200709528 Map 4-13-07 of the records of the Clerk and Recorder of Eagle County, Colorado. Every such description shall be good and sufficient for all purposes to sell, convey, transfer, encumber or otherwise affect the improvements, Lots, Units, and all appurtenant rights, benefits and burdens thereto, as created by the provisions of this Declaration, and each such description shall be so construed. This provision shall apply to the Properties as said term ("the Properties") is defined in this Declaration. PROPERTY DIVISION. (a) Declarant hereby subdivides Lot l 1 into two (2) parcels for ownership in fee simple by the individual and separate owners of Lot I IA and Lot 11B as more particularly Gordon/Party Wall Agreement and 2 Declaration of Covenants 7/20/2009 described on the Map thereof Each Lot shall be subject to the easements and setbacks noted on the Map and those set forth herein, as well as in the Declaration. (b) Lot 11 A and Lot 11 B shall have appurtenant thereto a non-exclusive reciprocal easement and right-of-way for ingress and egress, which shall be inseparable from Unit I IA and Unit 11 B. (c) No Owner shall bring any action for partition or division of Lot I IA and Lot 11 B. (d) In the event Lot 11 A and Lot 11 B are owned by the same entities, the doctrine of merger shall not apply. (e) The parties, if more than one, having the ownership of each lot, shall agree among themselves how to share the rights and obligations of such ownership; provided, however, that if a corporation, partnership, association or other legal entity shall become an Owner of a Lot, or if more than one shall have the concurrent ownership of a Lot, then such entity or concurrent Owners shall from time to time designate one individual who shall represent such entity or concurrent Owners in all matters concerning all rights and obligations pursuant to this Declaration. (f) Any such entity or concurrent Owner shall give written notice to the other Owner designating the individual to act on its or their behalf, and such notice shall be effective until revoked in writing by such entity or Owners. Any act or omission by such designated individual shall be binding on the entity or Owners having designated him in favor of the other Owner or any person who may rely thereupon. (g) Each Unit and Lot together shall be considered a separate parcel of real property and shall be separately assessed and taxes. 4. ENCROACHMENTS. If any portion of Unit IIA or Unit IIB now encroaches upon the other Lot as a result of the construction of any building, or if any such encroachment shall occur hereafter as a result of settling or shifting of any building, a valid easement for this encroachment and for the maintenance of the same so long as the building stands, shall exist. In the event any Unit shall be partially or totally destroyed as a result of fire or other casualty or as a result of condemnation or eminent domain proceedings and then rebuilt, encroachments of parts of the Unit on the other parcel due to such rebuilding, shall be permitted, so long as such encroachments are of not greater extent than those previously existing, and valid easements for such encroachments and the maintenance thereof shall exist so long as the building shall stand. 5. PARTY WALL. (a) The common wall placed equally divided on the common boundary separating Lot 1 IA and Lot I IB, the footings underlying, and the portion of roof (if applicable) over such wall are collectively referred to herein as the "Party Wall". Gordon/Party Wall Agreement and 3 Declaration of Covenants 7rzonol>9 (b) To the extent not inconsistent with this Declaration, the general rules of law regarding party walls and liability for damage due to negligence, willful acts or omissions shall apply to the Party Wall. (c) The Owners of each Lot shall have a perpetual easement in and to that part of the other Unit on which the Party Wall is located, for party wall purposes, including inspection, mutual support, maintenance, repair, replacement, and reconstruction. In the event of damage to or destruction of the Party Wall from any cause, then the Owners shall at joint expense, inspect, maintain, repair, or rebuild said Party Wall, and each Owner shall have the right to the full use of said Party Wall so repaired and rebuilt. Notwithstanding anything contained above to the contrary, if the negligence, willful act or omission of any Owner, his family, agent, guest, tenant or invitee, shall cause damage to, or destruction of, the Party Wall, such Owner shall bear the entire cost of repair, maintenance, or reconstruction, and an Owner shall bear the entire cost of investigation, maintenance, repair, or reconstruction, and an Owner who by his negligent or willful act causes the Party Wall to be exposed to the elements shall bear the full costs of furnishing the necessary protection against such elements. 6. LANDSCAPING, COMMON UTILITIESAND PARKING. (a) The Owners from time to time shall undertake such landscaping and general outdoor improvements including, but not limited to, driveway and parking areas, as they may mutually and unanimously deem proper for the harmonious improvement of both Lots in a common theme, and, except for any expense or liability cause through the negligence or willful act of an Owner, his family, agent, guest, tenant, licensee or invitee, which shall be borne solely by such Owner. Each Owner shall share all expenses, liabilities and general upkeep responsibilities with respect to such landscaping, exterior maintenance, (except painting as described below) and outdoor improvements including driveways, parking areas, walkways, and paving. However, it is understood and agreed to between the parties that each party shall be solely responsible for the general upkeep of their respective yards and landscaping on their Lots and shall bear said costs individually. (b) Common utility or service connections or lines, common facilities or other equipment and property located in or on either of the Units but used in common with the other Unit, if any, shall be owned as tenants in common of an equal undivided one-half (1/2) interest by the Owners of each Unit and, except for any expense or liability caused through the negligence or willful act of any Owner, his family, agent, tenant, guest, licensee or invitee, which shall be borne solely by such Owner, all expenses and liabilities concerned with such property shall be shared proportionately with such ownership. The Owner of the Unit on which such property is not located shall have perpetual easement in and to that part of such other Unit containing such property as is reasonably necessary for purposes of maintenance, repair and inspection. (c) It is expected that the common access easement and parking area will be provided on a portion of each of the Lots. There is hereby created a non-exclusive reciprocal easement and right-of-way for each Owner over, across and through that part of the other Owner's Lot as provided on the Map. The Owners shall have equal right to the use of such Gordon/Party Wall Agreement and 4 Declaration of Covenants 7/24/2009 access easement and no Owner shall hinder or permit his guests, tenants, invitees or others to hinder reasonable access by the other Owner and his invitees, guests or tenants to the other Owner's Unit or Lot, or park or permit his guests, tenants or invitees to park any vehicle in the access easement without the consent of the other Owner. It is presumed that snowplowing will be required from time to time and the costs of which will be shared equally by the Owners. Other maintenance, repair, or improvement of the parking access easement may be required from time to time, and the same shall be undertaken upon the unanimous agreement of the Owners who shall share all expenses, equally. (d) Certain water and sewer line easements, and utility and drainage easements contained on the Map are covered by the provisions of this agreement concerning access and financial obligations for repair, maintenance and replacement. 7. ALTERATION. MAINTENANCE, REPLACEMENT, AND REPAIRS. (a) In addition to maintenance provided for in paragraph 6, the Owners shall pay their proportionate share as allocated in paragraph 8 of the total cost allocated to each parcel, in order to provide exterior maintenance, exterior repair, and replacement upon the Units and all portions of the parcel upon which each Unit is located including, but not limited to the exterior of the Building, driveway, walkways, paving, and the roof of the building housing the Units (provided, however, that if the condition requiring repair or replacement only affects one of the Units, the Owner of that Unit shall bear the entire cost thereof). Repair, replacement or cleaning of exterior window glass shall be considered interior maintenance. If the need for repair is caused through the negligence or willful act of any Owner, his family, agent, guest, tenant, licensee or invitee, such Owner shall bear the entire cost of such repair or reconstruction (to the extent that such damage is not covered by insurance). Both Units shall be painted on the exterior at the same time and with the same materials, in the same color and brand, and quality of paint and stain and no exterior modifications shall be made to the exterior or color of the Building or Units without unanimous written approval of both parties and the Town of Vail and/or such other entity having regulatory control over such actions. All repairs at the joinder point of the respective roofs shall be borne equally by the parties; irrespective of which Unit, or which side of the party wall, the actual point of damage or failure necessitating the repair is located. (b) In the event an Owner fails to maintain, preserve, and replace as needed, the Unit, driveway, trees, shrubs and grass ("landscaping") within the property boundaries of his Lot commensurate with the standards set by this document and the Town of Vail Design Review Committee, or such other entity having regulatory control over such actions, the other Owner may, after fifteen (15) days written notice to that Owner (if within said time the Owner has failed to make a good faith effort to bring his landscaping into substantial conformity with the requirements of this document or the Town of Vail, contract with responsible parties to bring to standard the offending Owner's deficiencies and charge the Owner therefore with such cost shall be added to and become a part of the assessment to which such Lot is subject. The Owner hereby grants to the other Owner, its agents and assigns, an irrevocable easement to perform the aforesaid work. Gordon/Party Wall Agreement and Declaration of Covenants 7/20/2009 (c) Each Owner shall be solely responsible for maintenance and repair of the inside of his Unit including fixtures and improvements and all utility lines and equipment located herein and serving such Unit only; and window glass and frames shall be deemed interior maintenance. In performing such maintenance and repair, or in improving or altering this Unit, no Owner shall do any act or work which impairs the structural soundness of either Unit or the Parry Wall or which interferes with any easement granted or reserved herein, or he/she shall be liable for damages. (d) Utility or service connections or lines, facilities or other utility equipment and property located in, on or upon either of the Units or Lots, which are used solely to supply a service or utility to one Unit shall be owned by the Owner of the Unit using such utility or service and all expenses and liabilities for repair and maintenance shall be borne solely by the Owner of such Unit, which shall have a perpetual easement in and to that part of such other Lot or Unit containing such property as is reasonably necessary for purposes of maintenance, repair or inspection. (e) No Owner shall make or suffer any structural or design change (including a color scheme change), either permanent or temporary, and of any type or nature whatsoever to the exterior of his Unit, or construct any additional building or structure of any type or nature whatsoever upon any part of his lot without first obtaining the prior written consent thereto from the other Owner and any applicable governmental, Owner's association, or design and review committee. In case of damage or destruction of any Unit or any part thereof by any cause whatsoever, the Owner of such Unit shall cause with due diligence the Unit to be repaired and restored, applying the proceeds of insurance, if any, for that purpose. Such Unit shall be restored to a condition comparable to that prior to the damage, and in a harmonious manner, to promote the common theme of both Units. However, either Owner may without the previous written consent of the other add or enlarge their windows if approved by the applicable design and review committee; or the Town of Vail. (f) Snow shoveling and general maintenance of the common driveway access including paving and sealing shall be borne by the parties equally. 8. ALLOCATION OF EXPENSES. Common costs and common expenses of landscaping, paving, painting, alteration, maintenance, repairs and replacement, except as modified herein or as caused by the negligence or willful act of an Owner, shall be allocated in the following proportions: Lot 11A 50.0% Lot 11B 50.0% 9. MECHANIC'S LIENS.- INDEMNIFICATION. (a) Except for item(s) incurred as a common expense as provided for herein, if any Owner shall cause any material to be furnished to his Lot or Unit thereon or any labor to be performed therein or thereon, the other Owner shall not under any circumstance be liable for the Gordon/Party Wail Agreement and Declaration of Covenants 7/20/2004 payment of any expense incurred or for the value of any work done or material furnished; all such work shall be at the expense of the Owner causing it to be done, and such Owner shall be solely responsible to contractors, laborers, materialmen, suppliers and other persons furnishing labor or materials to his Unit or any improvements therein or thereon; nothing herein contained shall authorize either Owner or any person dealing through, with or under either Owner to charge the encumbrance whatever; and, on the contrary (and notice is hereby given) the right and power to charge any lien encumbrance of any kind against one Owner or against one Owner's Unit for work done or material furnished to the other Owner's Unit is hereby expressly denied. (b) Except as provided for below, if, because of any act or omission of any Owner, any mechanic's or other lien or order for the payment of money shall be filed against the other Owner's Lot, Unit or any improvements therein or thereon, or against any other Owner (whether or not such lien or order is valid or enforceable as such), the Owner whose act or omission forms the basis for such lien or other shall at his own cost and expense cause the same to be cancelled and discharged of record by posting a letter of credit, paying cash or obtaining a bond by a surety company reasonably acceptable to such other Owner, within twenty (20) days after the date of filing thereof, and further shall indemnify and save the other Owner harmless from and against any all costs, expenses, claims, losses or damages, including reasonable attorney's fees, costs, and expert witness fees resulting therefrom. 10. INSUR4NCE. (a) Each Owner shall keep his Unit and all improvements and fixtures insured against loss or damage by fire and extended coverage perils (including vandalism and malicious mischief) for the maximum replacement value thereof. (b) Each Owner shall provide and keep in force, for the protection of himself, general liability and property damage insurance against claims for bodily injury or death or property damage occurring in, on or upon, his Lot and the improvements thereon, in a limit of not less than $1,000,000.00 irrespective of bodily injury or death to any number of persons arising out of one accident or disaster, or for damage to property, and if possible against tort liability, such higher limits shall be carried. (c) Each Owner shall deliver to the other Owner certificates evidencing all insurance required to be carried under this paragraph, each containing agreements by the insurers not to cancel or modify the policies without giving the other Owner written notice of at least thirty (30) days. Each Owner shall have the right to inspect and copy all such insurance policies of the other Owner and require evidence of the payment of premiums thereon. (d) Nothing provided in this paragraph shall prevent the Owners from jointly acquiring a single policy to cover any one or more of the hazards required in this paragraph to be separately insured against by each Owner. Gordon/Party Wall Agreement and 7 Declaration of Covenants 7/20/2009 11. DESTRUCTION OF IMPROVEMENTS. (a) In the event of damage or destruction to a Unit by fire, flood, avalanche, or other disaster, the insurance proceeds, if sufficient to reconstruct the Unit, shall be deposited into a bank account which requires, for withdrawals, the signatures of both the Owners. The Owner shall then promptly authorize the necessary repair and reconstruction work and the insurance proceeds will be applied by the Owner to defray the costs thereof. "Repair and reconstruction" of the Units, as used herein, means restoring the improvements to substantially the same condition in which they existed prior to the damage with each Unit having the same boundaries as before. (b) If the insurance proceeds are insufficient to repair and reconstruct any damaged Unit, such damage or destruction shall be promptly repaired and reconstructed by the Owner using the insurance proceeds and the proceeds of a special assessment against the Owner of the damaged Unit. Any such assessments shall be equal to the amount by which the cost of reconstruction or repair of the Unit exceeds the sum of the insurance proceeds allocable to such Unit. Such assessment shall be due and payable not sooner than thirty (30) days after written notices thereof. The special assessment provided for herein shall be a debt of the Owner and a lien on his Lot and the improvements thereon and may be enforced and collected by foreclosure proceedings in the courts. (c) Notwithstanding the above, the Owners and first mortgagees of any or all of the destroyed or damaged Units may agree that the destroyed or damaged Units shall forthwith be demolished and all debris and rubble caused by such demolition be removed and the Lot(s) regarded and landscaped. The cost of such landscaping and demolition work shall be paid for by any and all insurance proceeds available. Any excess insurance proceeds shall then be disbursed to such Owners and their first mortgagees jointly. 12. RIGHT TO LIEN. (a) If an Owner, at any time, shall neglect or refuse to perform or pay his share of any obligation required hereunder, the other Owner may, but shall not be obligated to, after twenty (20) day's written notice, unless the circumstances require immediate action, make such payment, on behalf of such other Owner, expend such sum as may be necessary to perform such obligation including, but not limited to, the payment of any insurance premiums required hereunder or the undertaking of any work required hereunder for repair, restoration or maintenance, and such other Owner shall have an easement in or to the part of such defaulting Owner's Unit as is reasonably necessary for such work, repair, restoration or maintenance. (b) All sums so paid expended by an Owner, with interest thereon at the rate of eighteen percent (18%) per annum from the date of such payment or expenditure, shall be payable by the Owner so failing to perform (the "defaulting Owner") upon demand of the other Owner. (c) All sums so demanded but unpaid by the defaulting Owner shall constitute a lien on the Unit of the defaulting Owner in favor of the other Owner prior to all other liens and Gordon/Party Wall Agreement and 8 Declaration of Covenants 7/24/2009 encumbrances, except: (i) liens for taxes and special assessment; and (ii) the lien of any first mortgage or first deed of trust of record encumbering such Unit. The lien shall attach from the date when the unpaid sum shall become due and may be foreclosed in like manner as a mortgage on real property upon the recording of a notice or claim thereof executed by the non-defaulting Owner setting forth the amount of the unpaid indebtedness, the name of the defaulting Owner, and a description of the Unit. In any such foreclosure the defaulting Owner shall be required to pay the costs and expenses of such proceedings, including reasonable attorney's fees and costs. (d) The lien provided for herein shall be subordinate to the lien of any first mortgage or deed of trust, including all additional advances thereon. Sale or transfer of any Unit as the result of court foreclosure of a mortgage, foreclosure through the Public Trustee, or any proceeding in lieu of foreclosure shall extinguish the lien of such assessments as to payments thereof which become due prior to such sale or transfer, but shall not relieve any former Owner of personal liability therefore. The mortgagee of such Unit who acquires title by way of foreclosure or the taking of a deed in lieu thereof, shall not, however, be liable for future assessments on the date it becomes the Owner of such Unit. No sale or transfer shall relieve such Unit from lien thereof. In the event of the sale or transfer of a Unit with respect to which sums shall be unpaid by a defaulting Owner, except transfer to a first mortgagee in connection with a foreclosure of its lien or a deed in lieu thereof, the purchaser or other transferee of an interest in such Unit shall be jointly and severally liable with the seller or transferor thereof for any such unpaid sums. (e) Upon written request of any Owner, mortgagee, prospective mortgagee, purchaser or other prospective transferee of a Unit, the Owner of the other Unit shall issue a written statement setting forth the amount he is owed under this paragraph, if any, with respect to such Unit. Such statement is binding upon the executing Owner in favor of any person who may rely thereon in good faith. Unless a request for such statement shall be complied with within fifteen (15) days after receipt thereof, all unpaid sums which became due prior to the date of making such request shall be subordinated to the lien or other interest of the person requesting such statement. 13. ADMINISTRATION AND MANAGEMENT. Both Lot Owners shall be equally responsible for the administration and management of the obligations created hereunder. However, in the event that both Owners cannot agree when a decision is required by this Declaration, the impasse shall be resolved as follows: (a) Decision required in year 2000 and every even numbered year thereafter: Lot 1 I A Owner's decision is binding. (b) Decision required in year 2000 and every odd numbered year thereafter: Lot 11 B Owner's decision is binding. 14. OVERRIDE. In the event any Owner believes, based on the standard of the reasonable person, (i) that an impasse decision has been made incorrectly or contrary to the Declaration as (ii) that the Owner in ultimate control is guilty of mis-, mal-, or nonfeasance with respect to this Declaration then the aggrieved Owner, after first attempting non-binding Gordon/Party Wall Agreement and 9 Declaration of Covenants 7/10/2009 mediation upon written demand by the other Owner, and if the dispute is not resolved with 75 days, the parties may proceed to litigation, or arbitration, may petition the Combined Courts of Eagle County, Colorado for a judicial determination of the controversy which decision shall be binding upon both Owners. The Court shall assess costs and any reasonable attorney's fees as may have been incurred by the parties based upon the merits of the case, and award the prevailing party their costs and reasonable attorney fees. 15. USE RESTRICTIONS. (a) Each Unit shall be restricted to a residential dwelling as a permitted use, and to such uses, as well as conditional and accessory uses as shall be allowed by the Town of Vail Land Use Regulations as well as all covenants, declarations, restrictions, rules, P.U.D. Guide and all documents related to The town of Vail, Bighorn 5a' Addition Subdivision. (b) No exterior mounted radio, shortwave, television or other type of antenna, whatsoever, or tank of any kind, either elevated or buried, or clothesline or incinerator of any kind whatsoever or outside storage of any personal property shall be permitted or maintained on either Unit without the prior written approval of the other Owner. (c) No animals shall be kept or maintained in, on or upon either Lot or Unit, except that each Owner may keep and maintain within his Unit two domesticated dogs and/or two domesticated cats; provided, however, that such domesticated animals are kept under control at all times, do not present a nuisance to the Owner and are kept controlled in strict compliance with all Town of Vail ordinances that may apply to such animals, and in compliance all documents of record pertaining to and any rules and regulations for the Town of Vail, Bighorn 5'6' Addition Subdivision, as amended from time to time. (d) In addition to the parking restrictions set forth in paragraph b above, each Owner may keep no more than three (3) automobile vehicles permanently on his or her Lot. Parking of boats, trailers, campers, motor homes, ATVs or recreational vehicles on either Lot is expressly prohibited unless contained within the garage. Obstructing the common Access easement and parking area is expressly prohibited. lb. NOTICE. Each Owner shall register its mailing address with the other Owner and all notices or demands intended to be served upon Owners shall be sent by certified mail, postage prepaid, addressed in the name of the Owner at such registered mailing address. In the alternative, notices may be delivered if in writing, personally to Owners. 17. DURATION OF DECLARATION. Each provision contained in this Declaration which is subject to the laws or rules sometimes referred to as the rule against perpetuities or the rule prohibiting unreasonable restraints on alienation shall continue and remain in full force and effect for the period of twenty-one (21) years following the death of the last survivor of President Barack Obama or until this Declaration is terminated as hereinafter provided, whichever first occurs. All other provisions contained in this Declaration shall continue and remain in full force and effect until January 1, 2040 A.D., and thereafter for successive periods of ten (10) year extended duration, or this Declaration is terminated by recorded instrument directing Gordon/Party Wall Agreement and 10 Declaration of Covenants 7/20/2009 termination, signed by all Owners and all lienors holding a mortgage or deed of trust of record on any portion of Lot 11A and of Lot 11B. 18. AMENDMENT OR REVOCATION. This Declaration may be amended or revoked only (i) by Declarant so long as Declarant owns both Unit 11A and Unit 11B; or (ii) upon unanimous written approval in recordable form of all Owners and all lienors holding a mortgage or deed of trust of record on any portion of Unit 11 A or Unit 11 B. 19. EFFECT OF PROVISIONS OF DECLARATION. Each provision of this Declaration, and agreement, promise, covenant and undertaking to comply with each provision of this Declaration in good faith, and any necessary exception or reservation or grant of title, estate, right or interest to effectuate any provisions of this Declaration; (i) shall be deemed incorporated in each deed of or other instrument by which any right, title or interest in any portion of Lot 11A or Lot 11B, is granted, devised or conveyed, whether or not set forth or referred to in such deed of other instrument; (ii) shall, by virtue of acceptance of any right, title or interest in any portion of Lot 11A or Lot 11B, by an Owner, be deemed accepted, ratified, adopted and declared as a personal covenant of such Owner and his heirs, personal representatives, successors and assigns; and, shall be deemed a personal covenant to, with and for the benefit of each Owner of any portion of Lot 11 A or Lot I 1 B; and (iii) shall be deemed a real covenant by Declarant, for themselves, their heirs, personal representatives, successors and assigns, and also and equitable servitude, running, in each case, as a burden with and upon the title to each and every portion of Lot 11A and Lot 11B. 20. ENFORCEMENT AND REMEDIES. (a) Each provision of this Declaration shall be enforceable by any Owner in a proceeding for a temporary/preliminary or mandatory injunction or by a suit or action to recover damages. If court proceedings are instituted in connection with the rights of enforcement and remedies provided in this Declaration, the prevailing party shall be entitled to recover its costs and expenses in connection therewith, including reasonable attorney's fees. (b) Each Owner hereby agrees that any and all actions in equity or at law which are instituted to enforce any provision hereunder shall be brought in and only in the Combined Courts of Eagle County, State of Colorado. (c) Failure to enforce any provision of this Declaration shall not operate as a waiver of any such provision, the right to enforce such provision thereafter, or of any other provision of this Declaration. 21. EXERCISE OF RIGHTS. Any exercise of any right granted hereunder by one Owner with respect to the other Owner's Unit, including, but not limited to, the use of any easement granted herein shall be exercised in a manner which shall not unreasonably hinder, impede or impose upon such other Owner's use of his Unit. Gordon/Parry Wall Agreement and I 1 Declaration of Covenants 7/20/2009 22. SUCCESSORS AND ASSIGNS. Except as otherwise provided herein, this Declaration shall be binding upon and shall inure to the benefit of Declarant and each Owner and the heirs, personal representatives, successors and assigns of each. 23. SEVERABILITY. Invalidity or unenforceability of any provisions of this Declaration in whole or in part shall not effect the validity or enforceable part of a provision of this Declaration. 24. CAPTIONS. The captions and heading in this instrument are for convenience only and shall not be considered in construing any provisions of this Declaration. 25. CONSTRUCTION. When necessary for proper construction, the masculine of any word used in this Declaration shall include the feminine or neutral gender, and the singular the plural and vice versa. IN WITNESS WHEREOF, Declarant has executed this Declaration this day of , 2008. Meadowlark Development Partners, LLC a Colorado limited liability company By: /Z Its: Declarant `rex4s STATE OF CQ~,4A ) S ew ; K ) ss. COUNTY OF 1 •AGT= ) Subscribed and sworn to before me this 1fday of 2 1,,,,~ , 2009,rby ajg'-z Cc,4jc~ and Witness my hand and official seal. My commission expires: ti t 3 c I I C, [SEAL] Notary Public _~O~pP1 PVB4~~ LINDA B COOPER Notary Public, State of Texas My Commission Expires October 30, 2010 Gordon/Party Wall Agreement and 12 Declaration of Covenants x/202004 Consent By: Its: STATE OF COLORADO ) ) ss. COUNTY OF EAGLE ) Subscribed and sworn to before me this _ day of , 2008, by and Witness my hand and official seal. My commission expires: [SEAL] Notary Public Gordon/Party Walt Agreement and 13 Declaration of Covenants 7/20@009 "'7 F G nJ r i M , v v 2 C~ O /1HDI3H 2/1HDI3H - ~i ZI XVW .0-;9 1H9I3H S ?aJ r ~ fX N~ ~W J L'7 CuXL 1 fir. _ ED LL Q--L 4 r-. ~4Q ..J 2 W Wi '",Sr t= W L J W iJ W F SJ L LJ2 ,S..u-~ J 1-•-: O iJ O W3 L J a 4r F-.J J.K t C i r Sd Ll ;2 ~q1 7'-' 'LL p O<J ' L q H H~ w wr LAW viZ ~LL r Jr V'? a ? w u < !,J6 M L . S,~W Jed. TGw Jr~- (4 0 JL, SL V,LJ 47 < _ u J -u r r _ NJ Ww '~~?.Z.._ ;dal 2t~ Do z 2W Lid LJ C:v^J:'a =11L'C~: ' CL:J,=-W r Wes. L...7 -r l J ~Z ~S ~ J d Q ~ Q Tf LJ 5 -O L L7 S Q Wj Qfl: ~-Q . - MLj N w y y H J J Wr3 raw ~~LL ~rL Xt"W c ~w° LrC c ce 'r L Q O O N o + -I W f~ nnn~ u ~ J LL O 0 i Z I. ! L Isk 3 o I F- LjLn u 0 i i; K 0 L as ~ l! 1 LU lu "Z- 0) t,) TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES t~-a ('-c ALARM PERMIT Permit Status Applied : Issued . . Expires. A08-0109,-:WS01 _000 ISSUED 11/28/2008 01/06/2009 07/05/2009 Job Address: 4852 MEADOW LN VAIL Location.....: EAST UNIT Parcel No...: 210113104010 Project No OWNER MEADOWLARK DEVELOPMENT PARTN 11/28/2008 PO BOX 6605 TYLER TX 75711 APPLICANT PEAK FIRE & SECURITY 11/28/2008 14244 TERN DRIVE COLORADO SPRINGS COLORADO 80921 License: 855-S CONTRACTOR PEAK FIRE & SECURITY 11/28/2008 14244 TERN DRIVE COLORADO SPRINGS COLORADO 80921 License: 855-S Phone: (970) 518-1431 Phone: (970) 518-1431 Desciption: PRE-WIRE & FINAL FINISH OF LOW VOLTAGE FIRE ALARM SYSTEM (EAST UNIT) Valuation: $3,000.00 FEE SUMMARY Electrical > $0.00 Total Calculated Fees--> $344. 50 DRB Fee--------- > $0.00 Additional Fees > $0 .00 Investigation > $0.00 Total Permit Fee--------> $344 .50 Will Call > $0. 00 Payments > $344 . 50 TOTAL FEES--> $344 .50 BALANCE DUE--------> $0.00 Approvals: Item: 05600 FIRE DEPARTMENT 12/02/2008 drhoades Action: DN 1. Three sets of plans submitted. Since the duplex, three sets for each side are required (6 total) 2. Rate of rise heat detectors not allowed. Please submit with fixed temp detector 3. No reflected ceiling plans shown. 4. Sprinkler system is required contrary to plan note. 5. NFPA 72 2007 edition is incorrect. Please use NFPA 72 2002 edition. Robert Daly, Peak Fire & Security, was advised and will resubmit new drawings oni, 01/05/2009 drhoades Action: AP Approved as noted on plans. CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Tovyaa applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOgRS IN A Weft NE AT 970-479-2252 FROM 8:00 AM - 5 PM. CONTRACTOR FOR HIMSELF AND OWNER TOWN OF VAIL, COLORADO Statement Statement Number: R090000005 Amount: $344.50 01/06/200909:14 AM Payment Method:Credit Crd Init: DDG Notation: Peak Fire/Robert Daly Permit No: A08-0109 Type: ALARM PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: EAST UNIT Total Fees: $344.50 This Payment: $344.50 Total ALL Pmts: $344.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 FIRE ALARM PERMIT FEES 112.50 PF 00100003112300 PLAN CHECK FEES 232.00 Project/Street Address Contractor Inf ation: E Company: - Company Address: City: C.S Stat__ n~ Contact Name: Contact Ph: 770 5~481VD Town of Vail ntra /z __ZA~ Building/Complex Name: Value of Fire Alarm: (Labor & Materials) h Work Class: New < Addition( Remodel ) ( ) Retro-Fit ( ) Repair ( ) Other( ) i Work Type: Interior Exterior ( ) Both( ) Type of Building: Single-Family ( ) Duplex K) Multi-Family ( ) Commercial( ) Restaurant( ) Other( ) i Owner Name: j (For parcel contact Eagle County Assessors Office at 970-328-8640 or visit 1J www.eaglecouty.us/patie) Does a Fire Alarm Exist? Yes ( ) No( ) Doe Ap 0",_~"ffn Title: _F$E)=, date: ~~-t~S_~ Project 1 IcJ 0 1 U()U`Building Permit c 1 ,0 1-42 Alarm Permit HT9 -0 1 O 'F► r~00 F, %Sok- df InL" v]L - f tm i 1 (use additional sheet if necessary) ion No.: Z.~' -Z5 - 'J s~ Date Received: M NOV 26 2008 T0M_,N .QF 1L TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit Status Applied : Issued . . Expires. ~jp1-Ofy3 A08-0110 ISSUED 1 1 /28/2008 01/06/2009 07/05/2009 Job Address: 4852 MEADOW LN VAIL Location.....: WEST UNIT Parcel No...: 210113104010 Project No OWNER MEADOWLARK DEVELOPMENT PARTN 11/28/2008 PO BOX 6605 TYLER TX 75711 APPLICANT PEAK FIRE & SECURITY 11/28/2008 14244 TERN DRIVE COLORADO SPRINGS COLORADO 80921 License: 855-S CONTRACTOR PEAK FIRE & SECURITY 11/28/2008 14244 TERN DRIVE COLORADO SPRINGS COLORADO 80921 License: 855-S Phone: (970) 518-1431 Phone: (970) 518-1431 Desciption: PREWIRE & FINAL FINISH OF LOW VOLTAGE FIRE ALARM SYSTEM (WEST UNIT) Valuation: $3,000.00 FEE SUMMARY Electrical > $0. 00 Total Calculated Fees--> $344 .50 DRB Fee--------- > $0. 00 Additional Fees > $0.00 Investigation > $0 . 00 Total Permit Fee--------> $344 . 50 Will Call > $0 . 00 Payments > $344 . 50 TOTAL FEES--> $ 344 .50 BALANCE DUE--------> $o. 00 Approvals: Item: 05600 FIRE DEPARTMENT 12/02/2008 drhoades Action: DN 1. Three sets of plans submitted. Since the duplex, three sets for each side are required (6 total) 2. Rate of rise heat detectors not allowed. Please submit with tixed temp detecto: 3. No reflected ceiling plans shown. 4. Sprinkler system is required contrary to plan note. 5. NFPA 72 2007 edition is incorrect. Please use NFPA 72 2002 edition. Robert Daly, Peak Fire & Security, was advised and will resubmit new drawings onl• 01/05/2009 drhoades Action: AP Approved as noted on plans. CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town~pplicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOUR$ IN AD_1 U.)FTELEPHOI(E J(T 970-479-2252 FROM 8:00 AM - 5 PM. FOR HIMSELF AND OWNER TOWN OF VAIL, COLORADO Statement Statement Number: R090000006 Amount: $344.50 01/06/200909:16 AM Payment Method:Credit Crd Init: DDG Notation: Peak Fire/Robert Daly Permit No: A08-0110 Type: ALARM PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: WEST UNIT Total Fees: $344.50 This Payment: $344.50 Total ALL Pmts: $344.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 FIRE ALARM PERMIT FEES 112.50 PF 00100003112300 PLAN CHECK FEES 232.00 ~ Project/Street Address L,,~ ` ~ Q Project U U '0 Building Permit 1 1) 1 Contractor Inf atton: C O b 1 Company: z q7 % ~ i Alarm Permit ~ Company Address: tion of Work d Descri t il D City: S State: L-2) Zip: ngz--l I p e a e Contact Name: ~ ~ ~ Contact Ph: 7 76 L ` j E-Mail /e l1 (use additional sheet if necessary) Town of Vail Contra d Regi ation No.: S i X - - Value of Fire Alarm: $ 1 (Labor & Materials) Contr ctor nat equired) w,_.._ -._l...._..-..._._._..._., _.v__....- -I Work Class. Property Information New 04 Addition( ) Remodel( ) Retro-Fit ( ) Parcel a) d f 3 ~`i a I ) Repair ( ) Other( Legal Description: Lot* Block Work Type: Interior ~K) Exterior ( ) Both ( ) i ( . on: Subdivis s ~ Type of Building: Building/Complex Name: Single-Family ( ) Duplex Multi-Family ( ) Owner Name: ) Commercial( ) Restaurant( ) Other( (For parcel contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecouty.us/patie) W~ No( ) Does a Fire Alarm Exist? Yes O Date Received: ) . Does a Sprinkler System Exist? Yes ( ) No( as 3"I►~2TM~lV1 at MMed ~1 ~ D~ ( KJ_ NOY 2 6 2008 lltle: FlgC 1A)5-~-cm,c ~~N OF AI ~r a Este: 1 S_ n9 L )WN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT S. FRONTAGE ROAD /AIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES DEMO. OF PART/ALL BLDG. Permit # D07-0006 Project # Job Address: 4852 MEADOW LN VAIL Status ISSUED Location.......: 4852/4856 MEADOW LANE Applied...: 06/13/2007 Parcel No....: 210113104010 Issued 06/19/2007 --v b -I - a60 Expires.....: 12/16/2007 OWNER MEADOWLARK DEVELOPMENT PARTN06/13/2007 PO BOX 6605 TYLER TX 75711 APPLICANT SINGLETRAK BUILDERS, INC. 06/13/2007 PO BOX 4655 FRISCO CO 80443 License: 343-A CONTRACTOR SINGLETRAK BUILDERS, INC. 06/13/2007 PO BOX 4655 FRISCO I CO 80443 License: 343-A Desciption: DEMOLITION OF EXISTING STRUCTURE Occupancy: Type Construction: Phone: 970-668-1200 Phone: 970-668-1200 Valuation: $15,000.00 Revision Valuation: Total Sq Ft Added: 0 ***::**+r*r++s**********+a**+* s**a****+***s***s+**«*•*****►+***+►+►*****a*s***«***t*«* FEE SUMMARY ***+*#«*a+***++**++# Building > $251.25 Restuarant Plan Review--> $0. 00 Total Calculated Fees--> $417.56 Plan Check $163 .31 Recreation Fee--------------> $0 . 00 Additional Fees > $0.00 Investigation-> $0. 00 TOTAL FEES > $417.56 Total Permit Fee--------- > $417.56 Will Call-----> $3 . 00 Payments > $417.56 BALANCE DU1--------- > $0. 00 *~+**~*~*►**a**s***x***►*x*~**sr*****r►*s**►t*r►~*~~+*~r+r*.***+~*a*+#**~*+~.*a*s***r+*r~**r+****+*~*■+***+:**+.■.**.*****+.+**.~+**rr*~*~*.:*.+* Approvals: Item: 05100 BUILDING DEPARTMENT 06/18/2007 JS Action: AP Item: 05400 PLANNING DEPARTMENT 06/19/2007 RLF Action: AP Item: 05600 FIRE DEPARTMENT 06/15/2007 DRhoades Action: AP Approved as submitted. Asbestos abatement done by Hudpeth & Associates. Item: 05500 PUBLIC WORKS 06/14/2007 gc Action: COND See conditions. See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE 479-2149 OR AT OUR OFFICE FROM 8:00 AM 4 PM. TURE OF OWNER Or, CONTRACTOR FOR HIMSELF AND OWNER CONDITIONS OF APPROVAL Permit D07-0006 as of 06-19-2007 Status: ISSUED Permit Type: DEMO. OF PART/ALL BLDG. Applied: 06/13/2007 Applicant: SINGLETRAK BUILDERS, INC. Issued: 06/19/2007 970-668-1200 To Expire: 12/16/2007 Job Address: 4852 MEADOW LN VAIL Location: 4852/4856 MEADOW LANE Parcel No: 210113104010 Description: DEMOLITION OF EXISTING STRUCTURE ***********************************************Conditions:************************************************ Cond: 38 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479-2250. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0009066 No staging in the Right of Way. Entry: 06/14/2007 By: gc Action: AP TOWN OF VAIL, COLORADO Statement Statement Number: R070001014 Amount: $417.56 06/19/200701:18 PM Payment Method: Check Init: LT Notation: Singletrak Builders / ck 1212 Permit No: D07-0006 Type: DEMO. OF PART/ALL BLDG. Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: 4852/4856 MEADOW LANE Total Fees: $417.56 This Payment: $417.56 To tal ALL Pmts: $417.56 Balance: $0.00 ACCOUNT ITEM LIST: Account Code - Description Current Pmts - BP 00100003111100 BUILDING PERMIT FEES 251.25 PF 00100003112300 PLAN CHECK FEES 163.31 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 Separate Permits are CON' or electrical, plumbing, mechanical, etc.! INFORMATION COMPLETE VALUATIONS FOR BUILDING PERMIT (Labor & Materials) $ . C;er P ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ TOTAL: $ I tj~+,'~ pQ For Parcel # Contact Eagle County Assessors Office at 970-328-8640 or visit www. ea-We-count Parcel # okv11 Job Name: 0PA PO , 1 w L V-, Job Address:4fWV_ , r I t . Legal Description Lot:` ~Z Block: Filing: CIS Subdivision: p>1 ] ress: yAjL CO Phon!!b2AC9 ZfiA'5 Ar~hi ff i er: Tiq Vim Address: Phone.47O 1 I E ' Address: Gp Phone:: Detailed descriptio of work: L'elwvurlcu ISTI L~ 2E&!~~T-U~ze Work Class: New Addition ( ) Remodel ( ) Repair ( ) Demo f,A Other ( ) Work Type: Interior ( ) Exterior ( ) Both Does an EHU exist at this location: Yes( ) No ) Type of Bldg.: Single-family (A Two-family ( ) Multi-family ( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: ` No. of Accommodation Units in this building: No/T a of Fireplaces Existin : Gas Ap pliances Gas Los Wood/Pellet Wood Burning No/Type of Fire laces Proposed: Gas Ap pliances Gas Los Wood/Pellet Wood Burning NOT ALLOWED Does a Fire Alarm Exist: Yes( ) No ) 11 Does a Fire Sprinkler System Exist: Yes( ) No *****k**************************************FOR OFFICE USE ONLY***************************************************** Date Received: ` Received By: F JUN 1 2007 J F:\cdev\FORMS\Permits\Building\building_permit 4-17-2007.DOC Page 1 of 7 Huds h Associates, 16C, 4775 S. Smira Fe Circle Englewood, CO 80110 (303) 791-5562 www. hadspedihiz. net May 21, 2007 10 James March Singletrak Builders, Inc 701 Granite Street Suite #210 Frisco, CO 80443 (LI N~ Re: Request for Closeout for (4852 Meadow Lane ) Town of Vail OFFICE COPY This letter is to inform you that the aforementioned project has been completed in accordance to the contract. Hudspeth & Associates, Inc. removed and disposed of 32 SQ Feet of asbestos sheet flooring. This project was less than 160 sq feet and 260 linear feet, according to Colorado regulation #8 no permit is required for this project. The waste for this project will be disposed at a certified land fill and the original waste manifest will be sent to the owner. Enclosed you will find the following: Copy of General Abatement Certificate it is Hudspeth and Associates, Inc. (H&A's) understanding that this aforementioned list is conclusive and that all of the items that are contractually required to close this project are provided herein. If there is any discrepancy in the contractual items that are identified in the aforementioned list and provided herein, please provide a written correspondence via email, fax, or mail, no later than (May 29, 2007). If H&A does not receive a written correspondence by the aforementioned date than H&A will assume that the report is in accordance to the contract and will submit the final invoice. If you have any questions or require additional info-nation, please contact me at (303) 791-5562. Sincerely, Hudspeth and Associates, Inc. Jeffrey Kn v \ ight Director of Abatement Services Ob Zia WN 11 I~ JUN 19 2007 U I 0'v v "iii >r 'viA{L Remediation and Restoration Services / / s ' \ + \ `d \ n ZA is=~ /i/ i \ \ 10, --A ~'°y,~ 005 \ / / oa 5 \ / / / \ t\ a5 \ 0 OD Oc O OOx ~ ~ GZ]f=*i~f~Ti Amzm m r0 E^m N~nD c m zA P Zo X0z ZDZo u o zmtm z Dm0o j M z n nSZ; w u 'M -OZ m r. C o0Nzo v C, >ZXm OO~p. r ~ ~ N X zN.T_l O m O M Y O M D M D A 7 m 0 ; v O m Z m O Om cl \ \ No r \ \ \ \ mU O D W \ \ \ \ 02 :EM \ \ rN ~oc> mN O \ \ \ Oaa \ \ f -A m \ \ \ z N \ a\ \ \ % \ \ ° \ \ \ cE \ \ \ pm \ \ \ zo \ \ z> c m ixz ~ca im~ o:. oz V O r c) < f*1 cZi~;W mDDn Zm Z~ \ \ 0 U, pj a °m DO \ \ ll Z n m z p m m ~ Z D m z - °z \ \ Z ln ~ °~;U>0 CpDO m> C_ ]O om-{{ m0C 00 D~ \ \ m D A m O S 0 Z M O z m r O p \ \ F1 5~ ;U P Lon 5~ 1-< '0 00 MK z~yy M-ZM, mp-Z M 00 mm A\m O Ofm*IO Z~ O_vzi 0-,4 / \ \ r / NOA 0-D.'l~l m2MO> jD r~ (((2 m m 1 / / ~~Z yZZ lm7N OZ'rN p / Ac~ Zmor non(.-- mg z / ~ 9L mm m a~oF wo mm O~--1 > a 1 " 1 =1 ~ C to ~ ; C y O r~ 1 O O ~C mA m <Z m m m m lzz Z~*IZA-mi 0 m 0 fi7 Q Z (7 r- p mzm =vpm oa°-<o - m 0, d G LjTQI p D (C/! y m 0 m C:~A ' m 3 o0- O y m m Z 11 DC'S' 1 xm x M A Z w mE c Nzo 0~D '0. R o ° O N U r N mom oo.H!D Z N (A °'$D~ msf ?i-< ~ 1 O A CA N Lmo 0DN mgm S m D (J1 V O .p O ZO j 2' M 'p (T S m \ \ \ \ \ N t" t„ O 'O m 00 D m i ~f N / v O ■ °O m z Nd m o r,,A n N 0 'U O r F, w(010 ~ 0 M ~c M z m III z M r R UD p U Z J Z -o N mm ou IlVIPROVEMENT LOCATION CERTIFICATE Gore Range ~Br Se DAM' s/zs/zoos LOTS 11 & 12 , BLOCK 7, _ surveying, LLC XEV Or SE V,A„M M: 06-J47ilc BIGHORN SUBDIVISION FIFTH ADDITION P.0 (970) 479-'S8698 . fax (970) 479.0055 NO.: 06-J47 ' ` ' ' TOWN OF VAIL, EAGLE COUNTY, COLORADO a~nO, CO 816 X15 20 II JUN 13 2007 ,u Eu) TOWN OF VIGIL \ 0°5 ~ r \ O \ \ O 0 \ \ c \ m~ \ F z \ Zo \ ad)\ \ lr \ \ \ \ m~ \ w O \ \ mz \ m \ \ .°0. o i \ m A Z, m~ \ z A i / STATE OF COL Colorado Department of Public Health ; , and Environment .~:%//%s:. Air Pollution Control Division . . , ' C ctor ntra General Abatement This certifies that Hudspeth Associa,es, Inc GAC No: 84-1488347 has met the certification requirements of 25-7-507,C.R.S. andAir Quality Control Commission Regulation No. 8,Part B, and is hereby erform asbestos abatement activities in the state of authorized to ;...vv,,; p Colorado . Issued: 8119/2006 ` • ~ 8/19/2009 ires oit Ex • ~ ~ • p Record Number: 11191 \\\\~Z:• . lit ~e APCD RcpiescnPativc ,.,~1j~>•, =~Z~~%• SE HuV*d I Associatel,~ 100, r 4775 S. Santa Fe Circle 000 Englewood, CO 80110 ~♦,/j (303) 791-5562 www. hudspethbiz. net May 21, 2007 James March Singletrak Builders, Inc 701 Granite Street Suite #210 Frisco, CO 80443 Re: Request for Closeout for (4852 Meadow Lane) AP(>-"e -Jo -1 -v 3 This letter is to inform you that the aforementioned and disposed of 32 completed in of asbestos sheet the contract. Hudspeth & Associates, Inc. flooring. This project was less than 160 sq feet and 260 linear feet, according to Colorado regulation #8 no permit is required for this project. The waste for this project will be disposed at a certified land fill and the original waste manifest will be sent to the owner. Enclosed you will find the following: Copy of General Abatement Certificate it is Hudspeth and Associates, Inc. (H&A's) understanding that this aforementioned list is conclusive and that all of the items that are contractually required to close this project are provided herein. If there is any discrepancy in the contractual items that are identified in the aforementioned list and provided herein, please provide a written correspondence via email, fax, or mail, no later than (May 29, 2007). If H&A does not receive a written correspondence by the aforementioned date than H&A will assume that the report is in accordance to the contract and will submit the final invoice. If you have any questions or require additional inforimation, please contact me at (303) 791-5562. Sincerely, Hudspeth and Associates, Inc. Jeffrey Knight Director of Abatement Services JUN 19 2007 0 Remediation and Restoration Services TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit E07-0139 ~b6"1 -6 (_t3 Job Address: 4852 MEADOW LN VAIL Status ISSUED Location.....: 4852/4856 MEADOW LANE Applied..: 07/25/2007 Parcel No...: 210113104010 Issued . 08/09/2007 Project No i~b 1 -boi5 Expires. 02/05/2008 OWNER MEADOWLARK DEVELOPMENT PARTN07/25/2007 PO BOX 6605 TYLER TX 75711 CONTRACTOR BIG BEAR ELECTRIC, INC. 07/25/2007 Phone: 970-390-9221 P. 0. BOX 474 LEADVILLE CO 80461 License: 291-E APPLICANT MEADOWLARK DEVELOPMENT PARTN07/25/2007 PO BOX 6605 TYLER TX 75711 Desciption: RELOCATE COMMON LOT LINE BETWEEN LOT 11 AND LOT 12, BLOCK 7, BIGHORN 5TH ADDITION Valuation: $0.00 Square feet: 100 *#**#*##########k***#*##*###*#######k*#k*******##*#####**###*###### FEE SUMMARY Electrical > $51.75 Total Calculated Fees--> $54.75 DRB Fee--------- > $0.00 Additional Fees > $0.00 Investigation > $0.00 Total Permit Fee--------> $54.75 Will Call > $3.00 Payments > $54.75 TOTAL FEES--> $54 .7 5 BALANCE DUE--------> $0.00 Approvals: Item: 06000 ELECTRICAL DEPARTMENT 07/25/2007 shahn Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. TOWN OF VAIL, COLORADO Statement Statement Number: R070001474 Amount: $54.75 08/09/200701:10 PM Payment Method: Check Init: LT Notation: Big Bear Electric / ck 5722 Permit No: E07-0139 Type: ELECTRICAL PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: 4852/4856 MEADOW LANE Total Fees: $54.75 This Payment: $54.75 Total ALL Pmts: $54.75 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts EP 00100003111100 ELECTRICAL PERMIT FEES 51.75 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED ' O p~ Project ®1O~ O Building Permit Electrical Permit T *V& 970-479-2149 (Inspections). 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL ELECTRICAL PERMIT APPLICATION CONTRACTOR INFORMATION ectrical ritractor: J Town of Vail Reg. No.: 11 Contact Person and Phone #'s: VA f Z' ~ P, I pGT-i;?j 2°I I - 0niv ftizTtr.»2 M09'2-Z I E-MailAddress! blolblPAt'~lef_4narthlioK ntct Fax#: 111 ..40& Contractor Signature: 0A. A f a A `A . COMPLETE SQ.Y00TAGE FOR AREA "ORK AND VALUATION OF WORK (Labor & Materials) AMOUNT OF SQ FT IN STRUCTURE: ./C' 0 ELECTRICAL VALUATION: $ Jw Contact Eagle County Assessors Office at 970-328-8640 or visit www. eagle-county com for Parcel # Parcel # 1-1 `•p Job Name: AOCV, M~APow-' L4_1v: Job Address:413c,-Z tU Vwl..' Legal Description Lot: Block: Filing: Subdivision: Ad T AVI 2,&05'-1 Engi r• . Detailed description of work: l T-AWI TME aw Q T Work Class: New Addition ( ) Remodel ( ) Repair ( ) Temp Power ( Other ( ) Work Type: Interior ( ) Exterior ) Both( ) Does an EHU exist at this location: Yes( ) No ) Type of Bldg.: Single-family ( ) Duplex ( ) Multi-famil ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building:.. 2 No. of Accommodation Units irrthl building:, Is this permit for a hot tub: Yes No Does a Fire Alarm Exist: Yes( ) No Does a Fire Sprinkler System Exist: Yes( ) No *********************FOR OFFICE USE ONLY******* '****~**5*~~*****,~ ~I • Other Fees: Date Received: DRB.Fees: Accepted B Planner Sign-off: f F:\cdev\FORMS\PERMITS\Building\elecbcal-permit 11-23-2005.DOC Page 1 of 2 F VAIL 11/23/2005 To e 0 ~r * A Amendment to the 2002 N.E.C. Town of Vail Ordinance 4, Series of 2005 ❑ Overhead services are not allowed in the Town of Vail. ❑ • Undefgrouli services shf begin copdu t (PVC) from the utility transformer to the• electri_~ meter,, main ciNcepnec~t switdh, bnJ toathe Yl& Nedtrtical distribUti©n circuit breaker pameL ❑ The main disc0Fi'ta'4 t s*(4 shall, * readily.#&e0101 e, b~ Cq kA tq t ejffte ►ch Uhe exterior wall of the structure. All underground Conduits are required to be inVected before back-frlling1he trench. ❑ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are exempt. ' ❑ NM Cable (Romex) can be used only in single and multi-family dwellings net exceeding 3 stories Type NM cannot be used in any building mixed with Type A,B•E,F,H,I,M &5 occupancies ❑ Aluminum condwtorssmaller than size #8 are not permitted with the Town of Vail. TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES ❑ All installations of exterior hot tubs or spa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if;appiicle); ; ❑ If this permit is for installation of an exterior hot tub or spa on• a new elevated platform or deck over • At"aUo*4 4rade;"rau,rA~~t also}`obtain a building permit; ' ' ~ f ! • - ❑ If thisoVriii< is for-tn~tallation of an exterior hbrtub or spa on any existing deck or elevated platform, a str ral bngineer must review the existin6 Condition and verify that, it will support the added concentrafda1ba"d; ~Plaas4•opoll te' , jai'p, of., *OL4tu aengineers, ~toMpbd I erloi cdrfti'dg with this agpl_ir,6 ododel ih in ❑ ' a &ati-f~milR buitdi`r~i •~witK8 hbtrieo ®rs assocta~'idni rater of )3emission If this is a rert~ from the association is required. ❑ If this p ~"mit is f rya comm rci ,sp~c~;,~tv~o'(2~ yj of atafnped c ra in~s-are reg fired.; lac fipl one-line and panel sc~iAdi •ard required if load is added or d rstributioin is altered . , I . I have read and unde tand the above. Signature Date Signed If you have any ques ns regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can be reached on Monday thru Friday mornings between the hours of Sam and 9am. You may also leave a voice maii and the inspector will call you back. Y R F:\cdev\FORMS\PERMTTS\Building\electical-permit_11-23-2005.DOC Page 2 of 2 11/23/2005 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MR*VE' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit E09-0001 NDUP Job Address: 4852 MEADOW LN VAIL Location.....: UNITS A & B Parcel No...: 210113104010 OWNER MEADOWLARK DEVELOPMENT PARTN 01/05/2009 PO BOX 6605 TYLER TX 75711 APPLICANT BIG BEAR ELECTRIC, INC. 01/05/2009 Phone: 970-390-9221 P. O. BOX 474 LEADVILLE CO 80461 License: 291-E CONTRACTOR BIG BEAR ELECTRIC, INC. 01/05/2009 Phone: 970-390-9221 P. O. BOX 474 LEADVILLE CO 80461 License: 291-E Desciption: INSTALL 200 AMP SERVICES, WIRING AND LIGHTING FOR NEW TWO-FAMILY DWELLING Valuation: $0.00 Square feet: 7000 Project E 09-0001- Status ISSUED Applied..: 01/05/2009 Issued. 01105/2009 Expires. 07/04/2009 FEE SUMMARY Electrical Permit Fee--------- > $316.25 Total Calculated Fees--> $320.25 Investigation Fee--------------> $0.00 Additional Fees > $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee------------------- > $0.00 TOTAL PERMIT FEE---> $320.25 Total Calculated Fees > $320.25 Payments-----------------> $320.25 BALANCE DUE---------- > $0.00 APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 01/05/2009 JLE Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR ~e gal Date Print Name elec_prm_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090000001 Amount: $320.25 01/05/200903:47 PM Payment Method: Check Init: DDG Notation: Big Bear 6498 Permit No: E09-0001 Type: ELECTRICAL PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: UNITS A & B Total Fees: $320.25 This Payment: $320.25 Total ALL Pmts: $320.25 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts EP 00100003111100 ELECTRICAL PERMIT FEES 316.25 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ELECTRICAL PERMIT APPLICATION Project Address vw ~.rme V J-6 A Q Contractor Information Company: 9P0~r ~ "v I J ~'J 7~ Company Address: City: M-, of J) State: v1 Zip: Contact Name: ~_VJA4 n Contact Ph: Ce S / 9,a ~zz E-Mail: i 15 Town of Wil Contractor Registration No. I)-?/- Contractor ftnature ( Property Information Parcel 240 y0~ 7 L,- Legal Description: Lot # Blk # Subdivision Job Name: L t[P/„r1(I [Al (~J,_)E.(L (7V 1,L~ Owner Name: ~ (4r1( Mailing Address: li _ CL1g& ll9Os 7 .5217// (For Parcel # Contact Eagle County assessors Office at 970428-8640 or visit www.eaglecou nty. us/patie) Architect Designer ( ) Name: Engineer ( ) ins Detailed Description of Work: v 45 4'Q;_4'AU (Use additional sneet a necessary COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Material) Amount of SQ Ft 5 Electrical $ Work Class: New/ Addition ( ) Remodel ( ) Repair ( ) Other ( ) Building Type: Single-Family ( ) Two-Family w Multi-Family ( ) Commercial( ) Townhome ( ) Other( ) Date Received: 4mo~32o,2s JAN -5 2009 _ ,.0VVN cal= SAIL TOWNOF9AIL' Amendment to the 2002 N.E.C. Town of Vail Ordinance 4 Series of 2005 ❑ Overhead services are not allowed in the Town of Vail. ❑ Underground services shall be in conduit (PVC) from the utility transformer to the electric meter, main disconnect switch, and to the first electrical distribution circuit breaker panel. ❑ The main disconnect switch shall be readily accessible, and located next to the meter on the exterior wall of the structure. All underground conduits are required to be inspected before back-filling the trench. ❑ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are exempt. ❑ NM Cable (Romex) can be used only in single and multi-family dwellings. Type NM cannot be used in any building mixed with Type A,B.E,F,H,I,M &S occupancies. ❑ Aluminum conductors smaller than size #8 are not permitted. TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES ❑ All installations of exterior hot tubs or spa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if applicable). ❑ If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30" above grade, you must also obtain a building permit. ❑ If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and verify that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. ❑ If this is a remodel in a multi-family building with a homeowners association, a letter of permission from the association is required. ❑ If this permit is for a commercial space, two (2) sets of stamped drawings are required. Electrical one-line and panel schedules are required if load is added or distribution is altered. I have read and understand the above. tefdatUre- Date Signed If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can be reached on Monday thru Friday mornings between the hours of 8am and 9am. You may also leave a voice mail and the inspector will call you back. TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES (Y SPRINKLER PERMIT Permit F08-0109 Job Address: 4852 MEADOW LN VAIL Status ISSUED Location.....: UNIT B Applied..: 12/09/2008 Parcel No...: 210113104010 Issued . 12/16/2008 Project No Expires . OWNER MEADOWLARK DEVELOPMENT PARTN 12/09/2008 PO BOX 6605 TYLER TX 75711 APPLICANT CASTLE FIRE SPRINKLERS INC. 12/09/2008 Phone: (970) 688-0789 PO BOX 3878 AVON COLORADO 81620 License: 735-S CONTRACTOR CASTLE FIRE SPRINKLERS INC. 12/09/2008 Phone: (970) 688-0789 PO BOX 3878 AVON COLORADO 81620 License: 735-S Desciption: INSTALL FIRE SPRINKLER SYSTEM IN UNIT B Valuation: $12,000.00 FEE SUMMARY Mechanical $0.00 Restuarant Plan Review--> $0. 00 Total Calculated Fees $860.00 Plan Check $350. 00 DRB Fee--------------------- > $0. 00 Additional Fees-----------> $0. 00 Investigation-> $ 0 .00 TOTAL FEES--------------> $860 . 00 Total Permit F'ee---------- > $860. 00 Will Call-----> $0.00 Payments > $860. 00 BALANCE DUE--------- > $0.00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 12/16/2008 drhoades Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE DE SEVEN - URS IN ADVANCE BY TELEPHONE AT 970-479-2252 TOWN OF VAIL, COLORADO Statement Statement Number: R080002370 Amount: $860.00 12/16/200802:41 PM Payment Method: Check Init: DDG Notation: Castle Fire Sprinkler 1326 Permit No: F08-0109 Type: SPRINKLER PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: UNIT B Total Fees: $860.00 This Payment: $860.00 Total ALL Pmts: $860.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts - BP 00100003111100 SPRINKLER PERMIT FEES 510.00 PF 00100003112300 PLAN CHECK FEES 350.00 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES -j~0 -7 _ o SPRINKLER PERMIT Permit Job Address: 4852 MEADOW LN VAIL Status : Location.....: UNIT A Applied : Parcel No...: 210113104010 Issued. . Project No Expires. F09-0001 ISSUED 01/15/2009 01/22/2009 OWNER MEADOWLARK DEVELOPMENT PARTN 01/15/2009 PO BOX 6605 TYLER TX 75711 APPLICANT CASTLE FIRE SPRINKLERS INC. 01/15/2009 Phone: (970) 688-0789 PO BOX 3878 AVON COLORADO 81620 License: 735-S CONTRACTOR CASTLE FIRE SPRINKLERS INC. 01/15/2009 Phone: (970) 688-0789 PO BOX 3878 AVON COLORADO 81620 License: 735-S Desciption: INSTALL FIRE SPRINKLER SYSTEM IN UNIT A Valuation: $12,000.00 FEE SUMMARY Mechanical $0.00 Restuarant Plan Review--> $0.00 Total Calculated Fees $860 . 00 Plan Check $350.00 DRB Fee--------------------- > $0.00 Additional Fees-----------> $0 .00 Investigation-> $0.00 TOTAL FEES--------------> $860.00 Total Permit Fee > $860 .00 Will Call > $0.00 Payments > $860 . 00 BALANCE DUE--------- > $0 .00 Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 01/21/2009 drhoades Action: AP Approved as noted on plans. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM - 5 PM. 7l SIGNATURE OF OWNER OR CONTRACThR FOR HIMSELF AND OWNER TOWN OF VAIL, COLORADO Statement Statement Number: R090000057 Amount: $860.00 01/22/200910:05 AM Payment Method: Check Init: SAB Notation: 1327 CASTLE FIRE SPRINKLERS Permit No: F09-0001 Type: SPRINKLER PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: UNIT A Total Fees: $860.00 This Payment: $860.00 Total ALL Pmts: $860.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 SPRINKLER PERMIT FEES 510.00 PF 00100003112300 PLAN CHECK FEES 350.00 Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: • A Colorado Registered Engineer's stamp or N.I.C.E.T. level III (min) stamp • Equipment cut sheets of materials • Hydraulic calculations • A State of Colorado Plan Registration form • Plans must be submitted by a Registered Fire Protection Contractor Pr ec Street Ad ress: Office Use: -1 Q Project a 1 000 9 (Number) (Street) (Sui e Building Permit P;J 1 Building/Complex Name: Lb Sprinkler Permit Contractor Information- qq + IDA :Company: f e /V I i Detailed Description of Work:\ i Company Address: 1 i g vt -U t a--~I I , City: State: Zip. i F Contact Nam ✓ ^1 (use additional sheet if necessary) Contact P 970 O(S Cell: la ~v7 f i 1 Detailed Location of Work: ( E-Mail har7.C Town of Vail Co tractor Registra on N 73 5 j (use additional sheet if necessary) ;v ; Contractor Signature (required) Does a Fire Alarm Exist? Yes ( ) No Property Information Parcel -zt o l t 31 (For parcel contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecouty.us/patie) Tenant Name: Owner Name: Cie c 61"A e5 C~S~b"'1 t l e✓S Value of Fire SpTfA (Labor & Materials) Does a Sprinkler System Exist? Yes ( ) No Work Class: New,kAddition ( } Remodel ( ) Retro-Fit ( ) Repair ( ) Other ( ) Type of Building: i Family ( ) DuplexKMulti-Family ( ) Commercial restaurant ( ) Other - ' Date Received: J I r g~~ L lln= ~ ~'Yf1al~(O'~J Bir. O N" Oats: W -M -09 FIRE SPRINKLER PERMIT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT M1WO V= Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit M08-0081 ADUP Project PRJ07-6930 Job Address: 4856 MEADOW LN VAIL Status ISSUED ~ff Location.....: 4856 MEADOW LANE Applied..: 04/25/2008 Parcel No...: 210113104011 Issued . 04/25/2008 Expires . 10/22/2008 OWNER MEADOWLARK DEVELOPMENT PARTN 04/25/2008 PO BOX 6605 TYLER TX 75711 APPLICANT ALL TEMP CONTROL, LLC 04/25/2008 Phone: 970-668-0281 PO BOX 134 101 W MAIN ST FRISCO CO 80443 License: 389-M CONTRACTOR ALL TEMP CONTROL, LLC 04/25/2008 Phone: 970-668-0281 PO BOX 134 101 W MAIN ST FRISCO CO 80443 License: 389-M Desciption: TO ROUGH HEAT. HEAT SYSTEM TO INCLUDE 98%a EFFICIENT BUDERUS SMART 80 TANK, TO INCLUDE ALL LABOR AND MATERIALS. SNOWMELT AND 188,000 btU BOILER Valuation: $79,750.00 FEE SUMMARY Mechanical Permit Fee---> $1,600.00 Will Call $4.00 Total Calculated Fees--> $2,004.00 Plan Check > $400.00 Use Tax Fee------ > $0.00 Additional Fees--------> $0.00 Investigation > $0.00 TOTAL PERMIT FEE---> $2,004.00 Total Calculated Fees--> $2,004.00 Payments $2,004.00 BALANCE DUE---- $0.00 Item: 05100 BUILDING DEPARTMENT 04/25/2008 rlf Action: AP APPROVALS Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR ALL TIMES m ech ca n i ca I_p a rm i t_041908 TO AN INSPECTION REQUEST. Corid: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. Signature of Owner or Contractor Print Name y Dy e m echcanical_perm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080000537 Amount: $2,004.00 04/25/200802:49 PM Payment Method: Check Init: RLF Notation: 1842 ALL TEMP CONTROL LLC Permit No: M08-0081 Type: MECHANICAL PERMIT Parcel No: 2101-131-0401-1 Site Address: 4856 MEADOW LN VAIL Location: 4856 MEADOW LANE Total Fees: $2,004.00 This Payment: $2,004.00 Total ALL Pmts: $2,004.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts MP 00100003111100 MECHANICAL PERMIT FEES 1,600.00 PF 00100003112300 PLAN CHECK FEES 400.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 l APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNVMV TOV Project Z/ Building Permit -i* Mechanical Permit r t ir,~ 970-479-2149 (Inspections) 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL MECHANICAL PERMIT APPLICATION Permit will not be accepted without the following: I Room ut o ~m Dim n include: p g-i C) `0008 oict e L ti P -6 076 a Gas Li s. :/Spec Sheets CONTRACTOR INFORMATION LUMFLt i t VALUAI ION FOR MECHANICAL PERMIT Labor & Materials MECHANICAL: $ "15 d Contact Faa/P_ Cnrinty AccAoccnrc nfti-A at 47n_ 2~R_R~an .~r visit 1AJI-Al o~rrlo_l ~•.r~fi. ~s Parcel a 10 1 10 '4 Q ca Cf F Name: "C'Prh0 LAD 1--Y-~.1-L J- Q - - - _ Job Address: Legal Description 11 Lot: Block: Filing: Subdivision S tti1 Owners Name: q~ ddress:Soo s• A A ,tc. a5F Phone: n6 _1 I Address: Engineer,,)",.,',, Ty, 11 -Phone: 170--32$ _OS S Detaill tiop of,wprk: To row-Sln -t'~'~ ~C, i0 - 6% a ~.C~ ~c~. ek 5NS c~ v- I!-tom.. x.15. Srorvdr~l }~Y q~ oO Work Class: New Addition( ) Alteration ( ) Repair ( ) Other ( ) Boiler Location: Interior ( ) Exterior ( ) Other ( ) Does an EHU exist at this location: Yes( ) No( ) I Type of Bldg: Single-family( ) Duplex) Multi-family( ) Commercial( ) Restaurant( ) Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/Type of Fireplaces Existin : Gas Appliances Gas Los Wood/Pellet Wood Burning No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No ************************FOR OFFICE USE ONLY*********** Other Fees: Date Received: I Accepted By: F: \cdev\FORMS\Permits\Building\mechanical_permit_11-23-2005. DOC RSA... i ii ~ II+ I` 11/23/2005 s TQ V A y, NOTE: THIS PERMIT MUST BE POSTED ON JOBSI TE A T MWN*V Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 ;iZ p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT NDUP Job Address: 4852 MEADOW LN VAIL Location.....: Parcel No...: 210113104010 OWNER MEADOWLARK DEVELOPMENT PARTN 10/01/2008 RO BOX 6605 TYLER TX 75711 APPLICANT WESTERN FIREPLACE SUPPLY, IN 10/01/2008 Phone: 668-3760 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323-M CONTRACTOR WESTERN FIREPLACE SUPPLY, IN 10/01/2008 Phone: 668-3760 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323-M Desciption: INSTALL TWO TOP VENT AND TWO DIRECT VENT GAS FIREPLACES Valuation: $15,641.12 ALL TIMES Permit M08-0250 Project PRJ07-0008 Status ISSUED Applied..: 10/01/2008 Issued . 10/10/2008 Expires. 04/08/2009 .«.,.«.,....«.......,««......>,«.......«.......«««««„»..«...«««««......««`*«««««FEE SUMMARY«**,..«.««..««««........«..........«...«...»««....,««..«a..«...........«............ Mechanical Permit Fee---> $320.00 Will Call > $4.00 Total Calculated Fees---> $404.00 Plan Check > $80.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $0 $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $404.00 Total Calculated Fees--> $404.00 Payments-----------------> $404.00 BALANCE DUE--------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 10/01/2008 JLE Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUEST R INSPECTIO,t~I SHALL MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 Pfi~ or Contractor 16) Ll 6 & Date mechca nical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080001917 Amount: $404.00 10/10/200802:03 PM Payment Method: Check Init: SAB Notation: 2125 WESTERN FIREPLACE Permit No: M08-0250 Type: MECHANICAL PERMIT Parcel No: 2101-131-0401-0 Site Address: 4852 MEADOW LN VAIL Location: Total Fees: $404.00 This Payment: $404.00 Total ALL Pmts: $404.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Curre nt Pmts MP 00100003111100 MECHANICAL PERMIT FEES 320.00 PF 00100003112300 PLAN CHECK FEES 80.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 j> hantaat goi j„avout damn to R~to ctude, _ Mechancce Room Dimensions - Camhus lon fir Duct Size and Location r^ius, Vent and Gas Line Size and Location ilea; oaa Calculations Equipment Cut I Speedo Sheets Proact Rddtsss ~ ~ ~ ~ I fd i Aroject f L/ X) 0 _._...__,_......-,.._w.._.--...~._:._..~ Building Pemilt i Contractor Information ` t Mechanical Permit +v` 't'c'. I Company, Detailed Description of Work' -9ca ,114 rurvR 1^F ~1 1' Company Address; f City; State_ 1p 1! d ion Oey%~ a,,-,A 4A _b~-e_C' Contact Name, (111~ilx ~:.9 Contact Ph; .QUO-lJ t _ Ceil E-Mail: ~1 1 (Use additional sheet H necessary) - + Y 4 Town of Vail Contra Registrallon No; !`.Complete Valuation for Mechanical Parml!. h yy X Mechanical $ Contractor Signature (required) ` Property information Work Ctasa: Parcocl ir; d j©1 i t t New M Addition ( ) Remodel ( ) Repair ( ) Other goiter Location: ~i Legal C3exs4¢tkan:?o4# BtktF 2 Interlor ( ) Exterior ( ) Other ( ) Subdivislo r: _L c -sly E~._._.._.. _ _ l"1 _t►_ y_lr_--- No/Type Existing Fireplaces; .Iota Namo: ' I f Gas Appliances( ) Gas Lops ( ) Wood/Pellet { Owner tda, u If r ^ r~ LC NoRypa Proposed Ftnplaae: 1 F W) `Y "~~r r TA' j ,'7 i l Gas Appliances() Gas Lofts ( ) Wood/Pellet ( ) 1 Mailing Addre6r (F* ~r Ps^5el coital-It amts urr') sslaR3ors Od°ICS t >t Wr 0 -229.8640 or visit w,vwN.:snQlarounty r.ts'patis) ~ Building Type: Single-Faintly ( ) Two-Family (NI) Multi-Famlly ( ) Arctrltr;pct ( )ilpner engineer( Commercial ( ) Townhome ( ) Other Name. Phcne: Date Received: Fix. E-Mali: q0q,cf6 800;''700 3: 'r-id38I3 N831S3Ut 7 8417806 ~ VJ 70:1,1 8007!08;''60 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWWO Vy Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 PLUMBING PERMIT ADUP Permit Project Status Applied : Issued . Expires . P08-0025 PRJ07 -AWL 0002 ISSUED 04/25/2008 04/25/2008 10/22/2008 Job Address: 4856 MEADOW LN VAIL Location.....: 4856 MEADOW LANE Parcel No...: 210113104011 OWNER MEADOWLARK DEVELOPMENT PARTN 04/25/2008 PO BOX 6605 TYLER TX 75711 APPLICANT ALL TEMP CONTROL, LLC 04/25/2008 Phone: 970-668-0281 PO BOX 134 101 W MAIN ST FRISCO CO 80443 License: 381-P CONTRACTOR ALL TEMP CONTROL, LLC 04/25/2008 Phone: 970-668-0281 PO BOX 134 101 W MAIN ST FRISCO CO 80443 License: 381-P Desciption: TO ROUGH PLUMBING THROUGH SETTING FIXTURES TO INCLUDE ALL MATERIALS AND LABOR. Valuation: $35,250.00 FEE SUMMARY Plumbing Permit Fee---> $540.00 Will Call > $4.00 Total Calculated Fees $679.00 Plan Check > $135.00 Use Tax Fee---------- > $0.00 Additional Fees-----------> $0.00 Investigation---------> $0.00 TOTAL PERMIT FEES--> $679.00 Total Calculated Fees--> $679.00 Payments--------------> $679.00 BALANCE DUE-----------> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 04/25/2008 Of Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:01 AM - 4 PM. Signature of Owner or Contractor Print Name Date plmbpermt1_041908 TOWN OF VAIL, COLORADO Statement Statement Number: 8080000538 Amount: $679.00 04/25/200802:52 PM Payment Method: Check Init: RLF Notation: 1842 ALL TEMP CONTROL LLC Permit No: P08-0025 Type: PLUMBING PERMIT Parcel No: 2101-131-0401-1 Site Address: 4856 MEADOW LN VAIL Location: 4856 MEADOW LANE Total Fees: $679.00 This Payment: $679.00 Total ALL Pmts: $679.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts PF 00100003112300 PLAN CHECK FEES 135.00 PP 00100003111100 PLUMBING PERMIT FEES 540.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI Project Building Permit # `V Plumbing Permit f ~k r 970-_ 79-2149 (Inspections) 75 S. Frontage Rd. Q b~ ^O 06-g Vail, Colorado 81657 TOWN OF VAIL PLUMBING PERMIT APPLICATION 4 CONTRACTOR INFORMATION Plumbing Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:_`6$ H ~.i'Vl ~iNb 1,L4 - Dtt1J kejSoolpft •y85- 33`j1 E- D04 Rc. or' 0~e/• Cam Fax #:q-Xj-~1 Contractor.Signatu COMPLETE VALUATION FOR PLUMBING PERMIT (Labor & Materials) PLUMBING: $ SC5I a rj O Contact Ea0/P_ r_h.-i tv dccacc rc t)ffio`A Af' 07/i-?"__QXAA ~ viciF IA/I-A! f 12....i 1 .K Parcel # a I p 3 p 2-2 Job Name: Q" C-?vO0LC~ Job Address: 4A SZ MEwt OovJ LtF} N&- Legal Description [Lot:~~M[Block: [Filing: S Ste` Owners Name: 11 Address: 'S t t2. Phone Engineer: Address: "h5oh, Phone: 770- 3z-~s- 051, Detailed description of work: j 6 roi ~h ~1"-vnb.r•~ ^I.►iC_ I%.c.ct2 Cc11 ►xw•4eXi'a9,kS Work Class: New Addition ( ) Alteration( ) Repair ( ) Other ( ) Type of Bldg.: Single-family ( ) Duplex) Multi-family ( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: a No. of Accommodation Units in this building: ,~********,~>~***********FOR OFFICE USE ONLY********* ~,~*****x*****x*xx**x*~ 11 - 1n F:\cdev\FORMS\PERMITS\Building\plumbing_permit_11-23-2005.doc Page 1 of 1 11/23/2005 b ~o o ~ g (D b U) • O A o o O R 1.+ N N K O O V~`I N z c~ m o o QIA r N~`+C~00JO\CAA W N~-` H nnr~r~ d o s ~ ~ ~ f~D ~ A V°i y < < ~ ° a tD ~ ~ A fD Uj C~ K M ~ O 'AY A~ c m~~ C C Cn 0 n n B O A m n A7 a a~~ sy ~ ~ C J o a ^COYm v, r w .o a• n a A Z A M O N (b lp (D ; a a cl) CO 0 CD 0, ~y.~.e a o, o E X11 O rA ell a a O o W cn ~ m .l :3 a Q r-f rr CD (b =3 0 0 T1 z =3 ~ a CO) ~ o CAD 0 :3 M M3 fb C= o Q 0 ® n 00 UR n .Z O .P, O 0 (j) CA -O W N O p O K v O Un .P W N - D O m CD ' r- El j = n 0 5 Z -0 < U O n O c s 0 sv D, U o °O C v o 0 o. o° o Q ai rn =3 m Z ::r 0 0 CL :3 CD 0 ca o 0) -0 c 0) a- N @ N Z = co CA 0 ° O w co N Z O Z O n° CD 0) T o Ch :3 n~ 3 v sv C--0 CD CD CD n s m m w CD a = G S 0. m o 3 r (D 0) w to (D 0 CL K - 0 + ) CO CA cn 0 :3 CD 0 ED G) CD _ CD CD _ CD fD D6 :3 W u C7 O (D < cr N N 0 0) tD fD v (~~D O CD -w O X N CA M cn 'a Q X fD = 00.. a- CD cn Z II FP O O 0 2. Er Sv -0 CD co Q. Q• C II W O = CL m O 0 CD :3 C n fl? p lD .n. O O 0 07 O 11 -o to (D cc O 5 O 0 CD ° O 7 N O O-N N. S N fl S O cfl a m (D ° CD a O p p (D CD V+ Cf) CD Q O a O C o -0 O ? ID m N 0 0 n I 7 C 5' N S Q :3 0 y O O y C) CD CD II II II 11 m O sv CD co co (D C (D -0 _ -0 (A @ N. N cn (D C s $ CD O CD N C N C X a -0 CL N C (D _ co Co 9- cr CD 0 CL r j C p O W O O 0 0 C (D O to v Q N N N 0 'a 9D Q 0 CD N -p o Q N ? p a a O= 0 N, '0 a E. N 7 Q- O n om,, N m (D (O O 0 O S K CL CD ° CD S CD C 0 (fl 0 -0 ~ 0 n O N X O y 0 (D < CD CD 0 a) S C CD - O 3 3' N n C sZ N m :3 =r CD m co m CD m a co ° ° CL C7 a) ::r CD O c° o 5, X a m m CD CD 0) o ° M (D 0 5. CL CL :3 'a CL :3 M :3 (2. o :3 0) 0 0 CD --ft C~ CD CD < =r CD W CD 0 CL CL :3 0 0 CL 2:3 -a 0 CL - CD ) o o D O a _ o N N =r CD =r 0 CD o CD CD -a CD 0 0 ::r 7 0 CL N 3 CD O S 7 (D c v T n< N G) 0) CD 'a a) -0 W a) 6' CD m Q Q) N m - O (D =r l< -v Q $ z n O ca CD S N CD 0 0 O _ :E CD CD U) ::3 CL CD - 0 Q) 3 CL m a) =r 0 ° v o v o CD =r o a m = 5) < m< ° s a) m 3 cQ o co m m a R on CD =r (D 0 :T < (D CL CD =r O CD m y m co ca m cn o 0 m N o v CD 0 3 co v 0 (nn N n m 0 CD ~ cD O rA-► O 3 0 0 ~ O S -N ~ fn _0 3 CD 7 0 N $ 7 N - CD (D O O 7 a II 11 11 II a O ~ 0 Q Q c G CL (n tJ~ Vi 00 O W O C) to O (D 0 O 7 0 0 N tJ p 0 O o 0 ~ - TI 7 0 C0 « O ! < 0 CD N 0 O CL N = S CL n 0 m N ° o D m a Cs CD a < Cn CD o v O 0 S = n 0 CD CD :3 0 CD Q cn _ cn Q CD i ° z 4 O n r A W N J X o M. (D ( - m ~ m •o a n V cn CL 0 r z N co (n O p z 3 O sZ c C O = Z N W 'A O o N O Z O a 7 0 U) J y (D - W (!Q 3 • ;7 N rt. O cn =3 0 =3 O c :3 00 CD a O rt N _0 0 N S "O S -4 4h- 0 U) O O ^ m o O N 1! J ri) 0 Z OD 0 o m 0 m N) U) 3 JO O DO 0 C Q c m z 0 Z m 0 U) W C _.L I C rn 0 :3 CD O y 0 n 0 O_ O A~ I- o co r L n O Cf) . o o n \r,_ n (Ar tea-- ~ ~ I fl D Cf) 00 CD I r+ I ~ I i zz D m Rl~rF 5 1 -I CL - i ~ N 12 1 - I - _ - - :Icn CD T T . v Z ~ t I~ C) J _ - - - -r - D Gl7 T, .11 ° I CD O N 00 co C° CD _1 0 C) o I I I I u Lt f I I d) Q \ r-F Cs7 t . t P O W CL - - CD o-)~ 0 r -P ~9,~~ _ 00 A m l N O 7 r ~ O A M y g A C Q Q_ ❑ ❑ ❑ n Q_ O n Q O ° L s fD (n N Q rrl Q ❑ :3 X CL 0 O S 5x A rn Q < -1 ❑ s c ~ Q Q z 3 ° C<D C) 0 S U) D o ❑ O O `Q ❑ IX D r. rn ~ oD Q (D o r Q O c O_ o ~ O ~.r n ■ ■ ■ C ~ Q° O : fD ■ N • b • ■ N , or 0 DCD :3 ■ ■ Q D ■ z o M • D (D • Q ' r 0 ■ D ■ cn o cn o I I I i ■ ■ OZ> -4 S a Z o Z o Z o Z o 0 0 0 o a • • $ s ZK~ ■ ■ Z p o D 0 0 0 00-0 ~ o ' (D m Q ■ ■ N G7 G7 G7 n fi (D CD 0 ■ O (D Q Q 7 Q ■ 01 (J1 U1 cl1 > 0 o o o o ~ D • ■ ■ -N Q I n Z G) -Q -0 -a -0 Q' CD N • Q Q C Q n Q Q n C Q n tQ TI (D Q 0 N ~ 3 Q Q - 1 ; ■ / O O 7 (Q!1 W1, p ■ 0 o Q Q_ O7 a n a o 3 o o 3 CD Q_ O Q Q + ■ ~ =r ~ ~ O O O Q 0 ■ O N G) --,CL ~ ~p 00 CD 0 ; CD : w CD Q N O Q O O Z Q = O = N d7 Z U Q Q I I I Q _ -4- Q - U r-r ■ CO p W O p:3 (n p D;a IN I W Q C - :3 p N n 0 CD - ~F CD t O Q ■ ILO M n - CD 0 O I - o ~ ° 1 9 C N ~ o Sv ■ I O 0 r ■ L Jm co r .A, C1 0 4-11 00 A ~ N S O O J • i I i i i v : N I M. ~ M v (1 , p A on ❑ ■ V N A S s ❑ ■ O J ❑ ■ n V ! p (D ❑ ■ s g (D Q v s \ ❑ ■ O O y ❑ ■ O Ui o CD U) I I I I :3 Z Z Z 0 O O Z O 0 O ❑ ■ _ 7 z 0 _00 ~ 0 _00 ❑ ■ no n G) G7 G) G~ ❑ ■ Ul U1 U1 U7 v ° v • o N O ~ O O O ❑ ■ m m m -0 -a _0 m ~ ❑ ■ C c c c Q Q Q c Q N ~ CJ v O O c C Q . I m m ❑ ■ o (D ~ Q Q Q Q ❑ ■ 0 0 -Q o ❑ ■ S co D D ■ - O (DD ❑ ■ y N ° ❑ ■ r p ~ O ■ D ■ ~n v ° ~ ■ o o ❑ ■ A O ° ■ N o ooa~ ■ N Q ~ ~ (A Z G p p r+p ■ O (D \ x ~Q ■ (D (D 0 (D:3 D ■ 00 D Q I CD ■ C) Z C D G) O tQ m (D Q ' ■ 00 G) -u 1 (n (D p ~ O N co lp CD U 3 CD N ■ 00 UN W Q r r - ■ C) O O o C: CF) Q _ 0 O O G) :3 O (n 3 U O CD CA) ■ ■ C- : p O ~ O 0 CD _ ■ ■ 0) 0 ° 0 w Z Q v ' Q ■ o =3 0 o r 00 r ■ C n o ■ ■ ■ co A ~ S b y o ~ ■ 0 0 ■ W ZK6 ° o o ■ rn -I m Q o 03(D Q Q ■ O _0 rn =3 ■ Q _ -M' D (1) W Cf) D o ■ ~ n Z G) A (D Q 0 C ■ o vi cD O Q o m m Q 13 - ■ 3 0 (D N. Q i o O ■ v • O O O' O (D Q 4 ■ ■ 0 0 o CD CD U) 0 ■ ■ a 2. Q m . - ■ ■ Z Q i S o = ■ ■ s r4 r o c f N (D ■ ll r ~ / 0 . O `y" a \ CD ■ ■ < C ■ Q ❑ ■ O O ■ ■ m E - Q - N N cl 0 Ut W O ■ , CL T _ W co I I I cD 0 + N 0 Q CD 0 0 0 n N r+ o 0 0 0 r O ■ cn cr cr cn ■ ■ 0 o o o m m m m ■ 0 0 0 s ~ a s . - c c c Q Q o - c 0 ■ ■ Z w ° w v o o ■ o r~ M o o m Q ■ ■ 0 3 ? O CD ■ Z cD 0 (D a t i~ ❑ Q Q fi 0) o ❑ - n co ^ SJ J O o O N O rrl (n N OD C71 N 0 Q X Q Q 0- ❑ :10 o 0 o o = N ❑ ❑ 0) Q C: ° o ❑ ❑ ❑ Q M o =3 QO 0 ° ❑ ❑ . ~ ~ W lI~ 0 (J) o L CD v a) . O 0 0 0 ~ CD cD D r (.0 D C) :3 t°rno n O cD a o = o n~ - o r j cn ^ m M n 0 OD A G ~ N O A ' 7 O Z n p N A ❑ 00 t p m ❑ O ❑ ■ O O ° g N O 0 O ❑ O I w m. r+ 1 I I E3 3 o CAD OZ Z Z O O Z O ❑ E3 < S i U) 0' O O O ❑ ■ v 0 v v Cn (r 0 v 0 ❑ ■ 0 I O o o I -,I -,I o -1 ❑ ■ M m m m n ❑ ■ 0 o c c Q o 0 c 0 o 3 :3 r~ CD ❑ ■ N O O IQ I M m ❑ ■ o o Q N z ❑ ■ to Q ❑ ■ C to D' < ❑ ■ a n v s - C T rn ❑ ■ ❑ ■ r p o ❑ ■ ❑ ■ ❑ ■ v, p v ~ZD o 0 a? ❑ ■ a w zK: U, . 0 ❑ ■ 0 0 0 r o o m A tJ ~ m Q X -i + ❑ ■ O ~ CD 0 (D 0 71 ~ D~ ❑ ■ W a N 00DN 00 U) p ■ D I •z :3n(D C) m ❑ ■ ~n m m ~ U rn ~ ❑ ■ 3 0 CD N W Q ❑ ■ O o o 3 O) fD : a O ❑ ■ -4 oo O N 0 0 O ■ (p (p -Ti d m CO n c N O U) m ❑ ■ C) o 0 w Z 0 rn Q o = ❑ ■ z o ❑ ■ o Q w C _ :3 o o CD 1` c o Q 0 2 c~ O W o :3 0 73 vi iJl 11 vi J! u CL cD m r' E0 00 r C7 0 0 OD a 0 N a ~O 0 M c o x co V I O A O s V , n V (D z g• (D m ~ o ° ;;J 3 (D S U. c O. n 0 v ~ ° o 0 r m N ~ O ~ O O N ~ ~ ~ o I c O S9 ~ , r S ` 0 r0^ 1 y VJ 0 a o D M W (A -n A N -s I Z C I O n !2,-+ • O ' 3 In0 h<+31G 0 Z . 3 VI o(o SZ 3rA A3 3 O A C hNf 000<+3Z \ All z +hQb0 o r D _ 3~ OG n ° 3 pf-' AA3 p3 - 7K s m Q + D s u I, '9 o Psm r (n Ln 31+ 3 'i ~ X h N m S h C+ 0 SV MM 3, P N X -U '9 ZU' n Q n <A+- M ei N , ' NA 3 - 3 <+<Or O. 3 Z h2N 7FA v o N n D ~ :3 + to (11 p lp Z f1 0 S h h Q 3 P f P m z N O S Q f0 0 O p A O Q 1 Vh ) chi 3 e n 3 n ro n N 0 n5 P m3 st 7 sm ro h p -i p J X N 0 3 N ~ A m ~ .s O n -0d 30 Q NA f00 _ Z 3 n - O 0 Q w A3 y N O 0 Q h n U A h 3 -0 V/ O N 00 T CD OD 0 C7l U) N CD 0 Q.._ (O O _W Q C- c CD A O v ~ n O O ~ O CL r OD r n 0 A , ODD N v S 0 0 o 7 N Q O ~ O Q1 V ~ v # o 0 V V g g CD m ~ a• o ~ v S U. z O o a S ~ 0 N - o O , o O M ^ 1 - ~ fD l J `t1 0 V! $ C/) t o ' (D , c O o 1 n 1 ` 1 1 1 P C" , A d CO fD1 NO 3(n3 _9 -9 C AI O m \ t Sm. W O m3 ,+~3`c - 33 ~22G13A x Q~A-030=p3N eP+N E N N .+3 ry .Zl N l -h:3 :3 •D 5 n 3 Q Oxo ZP Q 9-d0 NP 3-q~ _ 0p P ^330 ,13 y) a 0 ° Q. 0 in x Q.ha m O n v +9 T, ~o z O O P 3 Q C O P UIN N Z IF ll:5 C ip O VJ ~ m 7 -tf 4 .3+ 3- UI ~ w o z I `G Q 7 "3 h< P N p n m 'l A C e,F n p N,. Lr- bcl N` p ~ fP1 3 O eF < 0 Q. 3 h (D 36 ~v Qan 04 =l aQ IEro CD N v0 h `Z y to O 3 o Q 3 to P n ~ n_ W h n Q :3 CL 3 (D P P 3 3 7 e} P 4 N 0 O N -1 e+ Q j O 4 N d = 3 3 P 3 V i0 70 o) 4 00 O N ~i VI Us ~i Ul ui J U U U (b cfl CD W 0 N U) o ap 0 O )o C Q_ ~G) O 0 CA CA) Q C- r+ cm :3 CCD rn0 o ° vP o ~ o 0 r OD r ~ C7 0 z O V) 0 0 CD i s 3 57 C g 3 x 0 0 U) R 3 3 g (D (D o r+ m ~ (D U) O 0 N Z O_ N 7 n O fD r w D g l0 JF 51 s ~:;~s: O ~d A O _O vi D Q+ C 4 z Z n f ~ ~ ~ 3 a-F H (D S 11= cn CD r ~ 7 -_I N N I'l N O c+ O 3 $ o c o f ~I \ to 0 C N a W ~ N ~ v N) O !D W (D x CF) G7 x °a ~ (D pC- o rn sfl V) C N 0 N N h (vjt (~D t0 O O 0 x 0 v z -u CD - 1,3 C 0 Q O 0 TI cp 'D 0) e 0 z CD a- CO ~ N N O O 1 \I 00 C7 O 00 0-~ O N 0 2 c0 CO CD -ni p 0D 3 CO 0 _0 CD CD cn N Cn (D 0 O o rn rn Q E_. O o u) w Q ~ C- CD rn0 o = :3 o C7 2 - 0 Al CL r 00 r Ul C7 0 Z O U) n O (D 0 Cn g CD CD a r+ v ZJ lrnV O U 0 A 7 A O a m g o ~ 0 ` o O f9 3v O r}. CD -TI n v Q n n t n ~ r ~ rt z ° z ° C.) ~ N° • O O J W N ~ O _0 O) (D 4~k. ao O ^ GJ N CO Cfl (D 00 N 0 U) o:10 0 O w C: O ~ N _W Q 0 CD O =:h O 1 v ~ C7 0 O =3 O 0 co r L n 0 N p 3 N 3 r0 to S E n O p L TI x I N ~,D x N ~,D x .p N ~D x N I,D p 3 r0 3 rD tA S N 1 I N h Z 1 -3 O rD W a+ CD ro bd r p O 3 3 Ul (D C") Z O O 3 3 ~ td O p C Z LA Ln N 3 n p x `I N x N ~D O7 _3 N O7 I ro Z 3 o ~ r bd to S i I O C+ z UI n ro S p n `D n o X m p ~ O to to x N ~D x N N I ,D W N C) p 3 r ~o O 3 3 r0 Z Ul 0 S .A w p 3 0 C r0 3 c+ n p Z O n fl CD v 0 n g CD CD o r+ m ~ CD U) O D n 0 0 a IT, o v 0 o o O " ~r H+ C °C ~ N N ~ O ~ Q m C7 Z a O O v ' q O ~ ° Cf) D IT Q m r s a S a w o z p o 0 w 0 1- -0 ~ (D-P.- O l+ i N b o CD c 00 O N U) 0o O (:Y) o Q _ O o W Cn wn C- I ~ c , CD rn ~ o o v P ¢1 0 O o -1 o CL r 0 r C n 0 0 m 0 ^ l ) 0 KT V (0 V/ m Z7 D z FTI ~JJ 0 _D F- l~ ~7DDco 0 D C) 0 fir- D x (n z~~-9 m o ;;U D D D r <zz O m O -P O 7 z O C M m O D D O z m D D_ Z ZC7G) D Z O D ~ n n m O Z O(D 70 ~ O z Wm (n ( m o O m x Z D Z O m cn ;;u m i I Cl) CC) m I- 1 O O r z O D m r- cn C/) = O n m m B07 -0143 : Entries for Item:540 - BLDG -Final C/O 15:56 01/29/2013 Action Comments By Date Unique_ Key CR A08- 0109,A08- 0110.F08 -0001, P08 -0025. SHAHN 08/27/2009 A000126 NOT FINALED. 926 GARAGE SEPARATION DOOR NEEDS. SHOWER TRIM IN BATH TUB ENCLOSURE MISSING THE LENS. AP martin 09/18/2009 A000127 1 709 Total Rows: 2 Page 1 E07 -0139: Entries for Item: 190 - ELEC -Final 15:58 01/29/2013 Action Comments By Date Unique_ Key AP shahn 08/13/2007 A000103 605 Total Rows: 1 Page 1 E09 -0001: Entries for Item :190 - ELEC -Final 15:58 01/29/2013 Action Comments By Date Unique_ Key CR spa tubs require acess. shahn 07/23/2009 A000125 bond across water meters. 995 provide gfci receptacles in master bath, medicine cab recepts alone not compliant. provide the 30ma trip circuit breakers for ice melt. note that the TV receptacle in the bath tub enclose has been removed as required by NEC. PA APPORVED FOR TCO. shahn 07/29/2009 A000126 ADDITIONAL CORRECTIONS: 112 ARC FAULT CIRCUIT BREAKERS ARE REQUIRED FOR ALL 120 VOLT OUTLETS PER NEC 2008 210.12. THE RECEPTACLE IN RECESSED COFFEE POT SHALL BE GFCI. ALL RECEPTACLES IN GARAGE INCLUDING OPENER TO BE GFCI. AP spa tub motors require permanant access. Still shahn 07/31/2009 A000126 did not test tubs. All else approved both sides 207 Total Rows: 3 Page 1 M08 -0081: Entries for Item-390 - MECH -Final 15:58 01/29/2013 Action Comments By Date Unique_ _ Key AP JRM 08/21/2009 A000126 751 Total Rows: 1 Page 1 M08 -0250: Entries for Item:390 - MECH -Final 15:59 01/29/2013 Action Comments By Date Unique_ Key CR NOT READY JRM 07/23/2009 A000126 004 AP shahn 07/29/2009 A000126 113 Total Rows: 2 Page 1 PO8 -0025: Entries for Item:29O - PLMB -Final 15:59 01/29/2013 Action Comments By Date Unique_ Key CR BOTH SIDES: shahn 07/20/2009 A000125 GAS RANGES NOT WORKING. 848 DW AIRGAP MISSING PER STATE OC COLORADO PLUMBING REQUIREMENTS. EAST SIDE LL BATH TOILET MISSING FLUSH CHAIN. MASTER TUB NOT INSTALLED. PAINT EXTERIOR GAS PIPE PER IPC CHAPTER 4. WEST SIDE BATHTUBS BOTH LOW FLOW. CR APPROVED FOR TCO. shahn 07/29/2009 A000126 WATER NOT WORKING. 114 ADDITIONAL CORRECTIONS: WATER SERVICE REGULATOR IN WRONG LOCATION PER ERWD. NO STILL REQUIRE AIR GAPS AT KITCHENS JRM 08/21/2009 A000126 ON THE DUPLEX 750 CR SNOW MELT NOT CONNECTED IN MECH SHAHN 08/27/2009 A000126 ROOM. 927 OTHER CORRECTIONS HAVE BEEN APPROVED. AP Martin 09/22/2009 A000127 759 Total Rows: 5 Page 1 CASH DEPOSIT FORMAT Receipt funnds to: Legal Description: Lot 11-f I'a ,Block M iling Address: J J Address: 4856 07 ne. V0 Q 4 7 Developer: a ^e, .� er. 11 Permit Number: 0'7-01y 0 "1 -OI Project Number: - O -0070 Improvement Completion Date: DEVELOPER IMPROVEMENT AGREEMENT THIS AGREEMENT, mad gg and eqtered into this 31 day of JJ11 , 20-91 by and among MArn. lissrf (the "Developer"), and the Town of Vail (the "Town "). 4 . WHEREAS, the Developer, as a condition of approval of the Temporary Certificate incv for '185al -? 1-185& AdalAwLaae, Ld4s )I -# la, 81k-7, 19.kr„ Sul S (address, legal description, and project number) wishes to enter into a Developer Improvement Agreement; and WHEREAS, the Developer is obligated to provide sec ' or collateral sufficient in the judgement of O,he ma <renable r for n certain improvements set forth in the attat in a nce with pp v ans ands cifications filed in the offs mm velopme �artme t' WHERveloper wishes to provide collateral to guarantee performance of this Agreement, including com ion of the all improvements referred to in this Agreement, by means of the following: 2 � W' The Developer agrees to establish a cash deposit account wl tie Town of Vail, as escrow agent, in the amount of $ 13,150 - oc) as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. NOW THEREFORE, in consideration of the following mutual covenants and agreements, the Developer and the Town agree as follows: 1. The Developer agrees, at its sole cost and expense, to furnish all equipment and materials necessary to perform and complete all improvements referred to in this Agreement. The Developer agrees to complete all improvements referred to in this Agreement on or before the 31 day of ce!ifeM r , 200 . The Developer shall complete, in a good workmanlike manner, all improvements referred to in this Agreement, in accordance with all approved plans and specifications filed in the office of the Community Development Department of the Town of Vail, and to do all work incidental thereto according to and in compliance with the following: a. All said work shall be done under the inspection of, and to the satisfaction of, the Town Planner, the Town Engineer, the Town Building Official, or other official from the Town of Vail, as affected by special districts or service districts, as their respective interest may appear, and shall not be deemed F: kxlev AFORMSAPermits\Planning Wdministrative_AdionslDlA cash format 5-1 E2007.doc Page 1 of 5 complete until approved and accepted as completed by the Community Development Department and Public Works Department of the Town of Vail. 2. To secure and guarantee performance of the obligations as set forth herein, the Developer agrees to provide collateral as follows: A cash deposit account with the Town of Vail, as escrow agent, in the amount of $ 13,-7.50- oo as collateral for the completion of all improvements referred to in this Agreement, in the event there is a default under this Agreement by the Developer. 3. The Developer may at any time substitute the collateral originally set forth above for another form of security or collateral acceptable to the Town to guarantee the faithful completion of those improvements referred to herein in this Agreement and the performance of the terms of this Agreement. Such acceptance by the Town of alternative security or collateral shall be at the Town's sole discretion. 4. The Town shall not, nor shall any officer or employee thereof, be liable or responsible for any accident, loss or damage happening or occurring to the work specified in this Agreement prior to the completion and acceptance of the same, nor shall the Town, nor any officer or employee thereof, be liable for any persons or property injured by reason of the nature of said work, but all of said liabilities shall be and are hereby assumed by the Developer. The Developer hereby agteos to.indemnify pi1d,told hatmless the Town, awd any of its officers, agen apd empjoyee�,.against any losses, claims, dama s, or, liabilities to which the Town or any fi!it�s, f ice '>agents or employees shay become subject to, insofar as any such losses, claims, damages or liabilities (or actions ifr reepect thereof) arise Aut of gr..are based upon any performance by the Developer hereunder; and the Developer shall reimburse the Town for any and all legal or other expensgs reasonabv incurred �b they Town in connection with investigating or defendeng any such`. loss, claim, darMige, lia�iri% or -' action. This indemnity provision shall be in addiWrt 0 6he other liability *ich the D`evelfoper my have. 5. It is mutually agreed that the Developer may apply for and the Town may authorize a partial release of the collateral deposited with the Town for each category of improvement after the subject improvement is constructed in compliance with all plans and specifications as referenced hereunder and accepted by the Town. Under no condition shall the dollar amount of the collateral that is being held by the Town be reduced below the dollar amount necessary to complete all uncompleted improvements referred to in this Agreement. 6. If the Town determines, at its sole discretion, that any of the improvements referred to in this Agreement are not constructed in compliance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vail or not accepted by the Town as complete on or before the date set forth in Paragraph 1 of this Agreement, the Town may, but shall not be required to, draw upon the security referred to in this Agreement and complete the uncompleted improvements referred to in this Agreement. Pursuant to Section 12 -11 -8, Vail Town Code, the Temporary Certificate of Occupancy referred to in this Agreement may be revoked until all improvements referred to herein are completed by the Developer or the Town in accordance with this Agreement. F: \cdev\ FORMS\ Permits \Planning\Administrative _Actions \DIA cash form at_5- 16- 2007.doc Page 2 of 5 If the costs of completing the uncompleted improvements referred to in this Agreement exceed the dollar amount of the deposit, the excess, together with interest at twelve percent (12 %) per annum, shall be a lien against the property and may be collected by civil suit or may be certified to the treasurer,of Eagle,County to be collected in the same manner as delinquent ad valorem taxes levied against such property. If the Developer fails or refuses to complete the improvements referred to in this Agreement, such failure or refusal shall be considered a violation of Title 12 (Zoning Regulations), of the Vail Town Code, and the Developer shall be subject to penalties pursuant to Section 12 -3-10 (Violations: Penalties) and Chapter 1-4 (General Penalty), of the Vail Town Code. 7. The Developer shall warranty the work and materials of all improvements referred to in this Agreement located on Town property or within a Town right -of -way, pursuant to Chapter 8-3, of the Vail Town Code, for a period of two years after the Town's acceptance of said improvements. 8. The parties hereto mutually agree that this Agreement may be amended from time to time, provided that such amendments be in writing and executed by all parties hereto. F:\ cdev\FORMS\Permits \Planning'Administrative Actions\D1A cash format 5- 16- 2007.doc Page 3 of 5 Dated the day and year first above written. • �i~aw2 �au t �,1v1 eveloper STATE OF COLORADO ) ) ss. COUNTY OF EAGLE ) The foregoing Developer Improvement Agreement was acknowledged before me this Day of JU W 20AIJ_ by. 016 -11 t; n Witness my hand and official seal. My commission expires �D /� �Cl, do /o 0I I I I I I III/I i N z �01AR}' c = CZ _ Pu6���' 'Q4, OF STATE OF COLORADO COUNTY OF EAGLE MAI V6/� �J, Town Planner )ss. The foregoing Developer Improvement Agreement was acknowledged before me this 31 Day of 20L by -,( 0. h. - Witness my hand and official seal. My commission expires: 1, ! 15 )ol0 `\�\NtuuuNq��i tary Pu We 0%— WP80MS\ Permits\ Planning \Administrative_Actions \DIA cash format_5- 16- 2007.doc Page 4 of 5 -;s • l i` L_ ATTACHED COPIES OF THE ESTIMATED BID(S) P ev \,at"n n VI 5'capi n lace- ve✓-�S ' ne- ((-6+;aAs ' �rts, me*rs, rn aY4 S , j -- -$ i X on F:\cdev\ FORMS\ Pennits\Planning\Administrative Actions\DIA cash fonnat_5- 16- 2007.doc Page 5 of 5 Oc7 PREPARED 8/21/09, 10:00:37 DEPOSIT REFUND REPORT- UPDATE. PAGE 1 PROGRAM MR415U Town of Vail ------------------------------------------------------------------------------------------------------------------------------------ CUST-ID CUSTOMER NAME TYPE CHARGE DEPOSIT DEPOSIT -ADJ ADJUSTMENT AFTER- REFUND CODE DESCRIPTION TX -DATE AJ -DATE AMOUNT AMOUNT AMOUNT AMOUNT ----------------------------------------------------------------------------------------------------- --- --- ------- ------ --- --- - - - --- 2894 MORNINGSTAR ASSET MANAGEMENT D2 DEP10 Dep- Developer Imp Agrmts 8/03/09 8/21/09 13750.00 13750.00 13750.00- .00 ------ - ------ ---- --- - - - --- -- ---- ----- -- ------- -- - --- TOTAL FOR CUSTOMER TYPE: D2 13750.00 13750.00 13750.00- .00 ------ --- - - -- ------ - - - -- -- ------ -- - - - -- ----- --- - - --- ------------- -- ----- ---- -- ----- --- -- - -- --- ---- - ---'- GRAND TOTAL: 13750.00 13750.00 13750.00- .00 DEPOSIT COUNT: 1 G/L BATCH CREATED: BATCH -02352 2009/08 USERID - JLOVATO AP HELD COUNT- .00 AMOUNT- 13,750.00 dun -�u�. 20.�y2007 3.,4 „2PM� OF SINGLETRAK, BU.ILDER,S INC pTpapp2462 No. ,203 IRREVOCABLE LETTER OF CREDIT FORMAT Legal DescripNort: Lots 11 and 12, Block 7 subdfvisiow Born loth Address: 4852 Meadow Lane Developer. Meadowlark Deveoopment Partners, U.0 Project Number. PRJ07 -0008 Permit Number: D07-0006 Improvement Completion Date: September 15, 2007 Letter of Credit apiration Date: June 20, 2008 f ELOPER IMPROVEMENT AGREEMENT THIS AGREEMENT, made and entmed into this 2& day of June, 2007 by and among Meadowlark Development Partners(the "Developer"), and the Town of Vail (the "Town ") and ;A474 k (the `Bank'). . Developer, as a condition of approval of the Demolition Permit for 4852 S and 12, Block 7, Bighom a Addition, PRJ07 -0008, wishes to enter into a meat Agreement and WHEREAS, the Developer is obligated to provide security or collateral sufficient in the judgement of the Town to make reasonable provisions for completion of certain improvements set forth in the attached estimated bid(s) in accordance with the approved plans and specifications filed in the office of the Community Development Department of the Town of Vall; and WHEREAS, the Developer wishes to provide security to guarantee performance of this Agreement, including completion of all improvements referred to in this Agreement, by means of the following: The Developer agrees to establish an Irrevocable letter of credit # I Z$ in the amocrd of $4375 with American National Bank as the security for the completion of all improvements referred th in this Agreement, in the event there is a default under this Agreement by the Developer. NOW THEREFORE, in consideration of the follo Ang mutual covenants and agreements, the Developer and the Town agree as follows: 1. The Devekgw agrees, at its sole cost and expense, to furnish all equipment and materials necessary to perform and complete all improvements referred to In this Agreement. The Developer agrees to complete all improvements referred to in this Agreement on or before the 15'h day of September, 2007. The Developer shah complete, in a good workmanlike manner, all improvements referred to in this Agreement, In accordance with all approved plans and specifications filed in the office of the Community Development Department of the Town of Vafl, and to do all work incidental thereto according to and in compliance with the foUewing: a. all said work shall be done under the Inspection of, and to the satisfaction of, the Town Planner, the Town Engineer, the Town Budding Off clal, or other offKM from the Town of Vail, as affected by special districts or service districts, as their respecdve Interest may appear, acrd shall not be deemed complete until approved and accepted as completed by the Community Development Department and Public Works Department of the Town of Vail. 2. To secure and guarantee performence of the obligations as set forth herein, the Developer agrees to provide security as fellows: Page 2 of 4 Jun -2 Jun. 20 0 2007 3; 43PI1� OF `SINGLETRAK BUILDERS INC OT04TIZ45Z T-572 No, 203905 P ' _3J Irrevocable letter of credit # ( 21 in the amount of 54376 (126% of the total costs of the affected estimated bid with Long's Excavation as the security for the - completion of as improvements referred to in this Agreement, in the event there is a. default under this Agreement by the Developer. 3. The Developer may at any time substitute the security originally set forth above for another form of sectirdy or collateral exceptable to the Town to guarantee the faithful cum pletlon of those improvements referred to in this Agreement and the performance of the temps of this Agreement. Such acceptance by the Town of altemative security or collateral shall be at the Town's sole discretion. 4. The Town Mall not, nor.shall any officer or employee thereof, be table or responsible for any accident, loss or damage happening or occurring to the work specified in this Agreement prior to the completion and acceptance of the same, nor shall the Town, nor any officer or employee thereof, be liable for any persons or property Injured by reason of the nature of said work, but all of said liabilities shall and are hereby assumed by the Developer. The Developer hereby agrees to indemnify and hold harmless the Town, and any of Its officers, agents and employees against any losses, claims, damages, or liabilities to which the Town or any of its officers, agents or employees may become subject too, insofar as any such losses, claims, damages or liabilities (or actions in respect them that arise out of or are based upon any performance by the Developer hereunder, and the Developer sM1 reimburse the Town for any and all legal or other expenses reasonably incurred by the Town in connection with investigating or defending any such loss, claim, damage, liability or action. This indemnity provision shall be in addition to any other liability which the Developer my have. 5. it Is mutually agreed that the Developer may apply for and the Town may authorize a partial release of the security provided to the Town for each category of Improvement at such time as such improvernents are constructed in compliance with all plans and specifications as referenced hereunder and accepted by the Town. Under no condition shall the dollar amount of the security provided to the Town be reduced below the dollar amount necessary to complete all uncompleted improvements referred to in this Agreement. 6_ If the Town determines, at Its sole discretion, that any of the improvements referred to in this Agreement are not constructed In compliance with the approved plans and specifications filed in the office of the Community Development Deparhywd of the Town of Vail or not accepted by the Town as complete on or before the date set forth In Paragraphl of this Agreement, the Town may, but spas not be required to, draw upon the security referred to In this Agreement and complete the uncompleted Improvements referred to in this Agreement Pursuant to Section 12 -11-8, Vail Town Code, the Temporary Cwrtlficate of Occupancy referred to in this Agreement may be revoked until all improvements referred to herein are completed by the Developer or the Town in accordance with this Agreement• if the costs of completing the uncompleted improvements referred to, in this Agreement exceed the dollar amount of the security provided to the Torn, the excess, together with irdemst at twelve percent (12%) per annum, shall be a lien against the property) and may be collected by civil suit or may be certified to the treasurer of Eagle County to be collected In the same manner as delinquent ad valorem tames levied against such property. 0 the Developer falls or refuses to complete the Improvements referred to in this Agreemient, such fallure or refusal shall be considered a violation of Title 12 (Zoning Regulations), of the Vail Town Code, and the Developer shall ba subject to penalties pursuant to Section 12-3-10 (Violations: penalties) and Chapter 1-4 (General Penalty), Vag Town Code. Pop 3 of 4 Jun -2Jun. 20. 2007 3r i 43% SINGLETRAK BUILDERS INC eT04Ti2452 T- 5T9No; 2039105 P; t4J 1� �111V VV�wIVI \111 V1.t LLVI M►Itl t��• 7. The Developer shalt warranty the work and materials of all improvements referred to in ft Agr+aement located on Town property or within a Town right -4 -w3y, Pursuant to Chapter 8-3, of the vail Town Code. for a period of two yms after the Town's acceptance Of aaW improvements. S. The patties hamto nxau -dl agree that this Agreement may be amended from time to dme, provided that such amendments be in writing and executed by all parties hereto. Dated the day and y above AMS DevelopmeM Inc - Pr*d Manager STATE OF S C j ) ss. COUNTY OF D ) The foregoing Developer trtlpmve<nent Agreement was adknowledged before me this 21°` Day of June, 2007 by Gregory M. Amsden, President of AMS Development, Inc. Witness my hand and official seal. My commission expires 8 a' `{ jaw 0 Pd�U.l, A - Tn e h, Notary Public STATE OF COLORADO ) )ss. COUNTY OF EAGLE ) The foregoN Developer Improvement Agreement was acknowledged before me this pay of u y 007, by Rachel Friede, Town Planner_ witness my hand and offldai seal. wAWA "Rift My Commission expires: A4 L( Gl Notary P bflo Paps 4 d 4 y ;NE C,4 Q4, --*N 0 lam; %, ,c';, � � •;;aP�� Jun- 2lun.. 20._ 2001 3.;42 A uF �SINGLETRAK BUILDERS INC I .......... qvi :41W Community Development 75 South Frontage Road Vail, CO 81657 9704792452 T -579 No. 2 0 3 905 P- _ �J LETTER OF CREDIT DEVELOPER IMPROVEMENT AGREEMENT Instructions: This page should be given to your lenderMank and returned with your letter of credit. Project Name: Meadowlark Development Partners, LLC Project Number. PRJ07 -0008 Permit Number: D07 -0006, Planner. Rachel Friede r 2g Letter of Credit Number. Issuing Bank: American National Bank Pops 104 AmericanNationalBan Member Sturm Financial Group LETTER OF CREDIT #128 JUL 06 2007 IU TOWN OF VAIL BENEFICIARY: DATE: June 26, 2007 Town of Vail EXPIRY DATE: June 20, 2008 75 S Frontage Rd Vail, CO 81657 COP IRREVOCABLE STANDBY LETTER OF CREDIT To Whom It May Concern: We hereby open our Irrevocable Letter of Credit in your favor available by draft at sight draw on the American National Bank for any sum or sums not exceeding in total the sum of $4,375.00 for the account of Meadowlark Development Partners, LLC, A Colorado Limited Liability Company, Lots 11 & 12, Block 7, Bighorn 5h Addition, Vail, CO. For the purpose of guaranteeing construction of public improvements required by Town of Vail pursuant to that certain Developer Improvement Agreement between Town of Vail relative to Meadowlark Development Partners, LLC. Each draft drawn on American National Bank sight shall be endorsed on the reverse side of this Letter of Credit and bear upon its face Drawn under Letter of Credit Number 128, dated June 26, 2007, and shall be accompanied by a resolution of the Town of Vail, 1) That there has been a default under the Developer Improvement Agreement, and 2) That a sum certain is required to remedy the default. The American National Bank agrees with the drawers, endorsers and bonafide holders of drafts drawn and negotiated in compliance with the terms of this Letter of Credit that such draft will be duly honored upon due presentation at the county of this bank. American National Bank represents and warrants to the Town of Vail that it has the full authority and power to issue this Letter of Credit to the Town of Vail in the total amount and for the period of time stated herein; said authority being pursuant to the laws of the United States, or the State of territory which governs the establishment and regulation of American National Bank charter, by -laws and other applicable rules and regulations adopted pursuant thereto. Should it be necessary for the Town of Vail to file suite in an effort to enforce the Irrevocable Letter of Credit, American National Bank hereby waives all venue right and submits to the jurisdiction of the District Court in and for the Town of Vail. All drafts hereunder must be drawn on or before June 20, 2008. This letter of credit is also governed by the Uniform Customs and Practice for Documentary Credit, International Chamber of Commerce Publication No. 500 (the UPC), which shall in all respects be deemed a part hereof as if incorporated herein. Aspen Fruits ■ ■ Boulder s Carbondale s Colorado Springs ® Denver ■ Eagle ■ Edwards Glenwood Springs ■ Grand Junction s Greeley a Mountain Village ■ Rifle C Telluride www.anbbank.com ■ Member FDIC Very Truly Yours AMERICAN NATIONAL BANK Dillon B. DeMore, Vice President Attest• l 2�� A TOWN OF YE Department of Community Development 75 South Frontage Road Vail, Colorado 81657 970- 479 -2138 FAX 970- 479 -2452 www.vailgov.com August 15, 2007 Meadowlark Development Partners, LLC P.O. Box 6605 Tyler, TX 75711 Re: Developer Improvement Agreement, letter of credit #128 To Whom It May Concern: Enclosed you will find the original letter of credit #128 from American National Bank for 4852 Meadow Lane, Vail, Colorado. This letter would have been returned to the bank but there was no address on their letter of credit. Feel free to contact me with any questions at 970 - 479 -2150. Sincerely, Lynne Campbell Office Manager Enclosure: American National Bank, letter of credit #128 40 RECYCLED PAPER