Loading...
HomeMy WebLinkAboutM09-0158NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT TOWNOFYAII, Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT AMF Job Address: 4630 VAIL RACQUET CLUB DR VAIL Location.....: UNIT 3, VAIL RACQUET CLUB Parcel No...: 210112406003 OWNER LINDA ROOSEVELT LAMBERSON RE 08/25/2009 2642 C S XANADU WY AURORA CO 80014 APPLICANT BLACK DIAMOND FIREPLACE LLC 08/25/2009 Phone: (719) 293-0481 PO BOX 7 LEADVILLE CO 80461 License: 410-M CONTRACTOR BLACK DIAMOND FIREPLACE LLC 08/25/2009 Phone: (719) 293-0481 PO BOX 7 LEADVILLE CO 80461 License: 410-M Desciption: INSTALL GAS FIREPLACE AND FLUE PIPE Valuation: $1,312.00 ALL TIMES Permit M09-0158 Project PRJ09-0386 Status ISSUED Applied 08/2512009 Issued . 08/31/2009 Expires . 02/27/2010 *,.,.....~,....~...*.......~*~*~...,~.<............*.....**~*~,....,*..~.~*>*......:**FEE SUMMARY.~~...~.**~~«*..****~....**......».~~~.,.,~.,...*....,........~«.*«~.....*~~.,.«.......... Mechanical Permit Fee---> $40.00 Will Call > $4.00 Total Calculated Fees $54.00 Plan Check > $10.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $54.00 Total Calculated Fees--> $54.00 Payments-----------------> $54.00 BALANCE DUE--------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 08/28/2009 JRM Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS mechcanica I_permit_041908 I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUEST O INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4P Z ignatu of Owner Contractor -r Dater Print Name mechcan ical_perm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001105 Amount: $54.00 08/31/200909:58 AM Payment Method: Cash Init: SAB Notation: CASH Permit No: M09-0158 Type: MECHANICAL PERMIT Parcel No: 2101-124-0600-3 Site Address: 4630 VAIL RACQUET CLUB DR VAIL Location: UNIT 3, VAIL RACQUET CLUB This Payment: ACCOUNT ITEM LIST: Account Code MP 00100003111100 PF 00100003112300 WC 00100003112800 Total Fees: $54.00 $54.00 Total ALL Pmts: $54.00 Balance: $0.00 Description Current Pmts MECHANICAL PERMIT FEES 40.00 PLAN CHECK FEES 10.00 WILL CALL INSPECTION FEE 4.00 The following items MUST be attached to this Permit application Mechanical Room Laygul drawn to scale to include: _ Mechanical Room Dimensions _ Combustion Air Duct Size and Location Flue, Vent and Gas Line Size and Location Heat Loss Calculations Equipment Cut / Spec Sheets Protect Address 11 f P J0 _(g 2- ~t X J Project - Building Permit M Contractor Information ( # H Company: Company A~dress: P City: , t71~► ~l . State_ : zip: __;!Xl_.!e[___ Contact Name: (216 te 6.0eal q ~1 Contact Ph: Cell: E-Mail: 1011042 Town of Vail ontractor Registration No YJ .-in / Contractor 319naturiii (required) Property Information Parcel 4 / o Wy0,6Q a Legal Description: Lot # Blk # Subdivision: qunif~ 3 411 paw...1 Job Name: 9✓r -6 F 81"7 17 Owner Name: 012 Mailing Address: ~GV~ L S..rl t ftrltr' ! (For Parcel 0 Contada-County sors Office 970-328.8640 or Visit www.eaglecounty.us/pa ie) /~v rvo- Co . kv v r Y Mechanical Permit . Detailed Description of Work: ,1 &kil f aKd I (Use additional sheet If necessary) Complete Valuation for Mechanical Permit: 00 Mechanical $ ~TC ?&2 Work Class: New ( Addition ( ) Remodel Repair ( ) Other ( ) S'YIARiMd~.~1tC:~::l ~ fL '3lI:~F~:~R^1'JC4.::~1^...':r.~.~~ ~VBS:S'~~59.::.'J:l./~~..:. "~Z'.~~r••_~C~'siL:l::•.:..:: ' Boller Location: Interior ( ) Exterior ( ) Other ( ) No/Type Existing Fireplaces: Gas Appliances( Gas Logs ( ) Wood/Pellet ( ) NofType Proposed Fireplaces: ti Gas Applianoes(tX) Gas Logs ( ) Wood/Pellet ( ) w Building Type: Single-Family ( ) Two-Family Commercial Townhome ( ) Architect( ) Designer( ) Engineer( Name: Phone 1 Fax: E-Mall: Date Received: 1 i Multi-Family ( ) ) Other( TOWN OF VAIL [E' F H w IE AUG 2 4 2099 2009-08-24 11;39 Black Diamond Firepl 719-293-0481 9704792452 P 114 2009-08-24 11:39 Black Diamond Firepl 719-293-0481 9704792452 P 414 Gmail - Fwd: P324/325 B vent Page 1 of I Gmjii Charles Ooerdt <blackdlamondtimplsce@gmall.com> Fwd: P3241325 B vent 1 message Michael Esta1 <mssteil@fmiproducts.com> Fri, Aug 14, 2009 at 9:27 AM To: blackdiamondfireplace®gmall,com Tillie, This Is the correspondence between the engineer and myself in regards to transitioning from 6" to 7" on the vent pipe. Thanks, Mike Michael Estell --Original Memage,- From: Ilitonjva®fmiproducts.com [mallto:llitonjua@fmiproducts.com) Sent: Thursday, August 13, 200811:25 AM To: IMIchni Este Subject Re: P3241325 8 vent Mike, I don't see any problem doing this. This needs to be approved by local code or inspector Leo L. -Original Message---- From: Michael Estell [mailto:mestell@fmiproducts.comj Sent: Thursday, August 13, 2008 06:08 AM To. 'Litonjua, Leo' Subject: P3241325 8 vent Leo, I have a customer who wants to increase the vent size from 6" to 7" using a listed transition adaptor. Do you see any proble with doing this? I know you cant decrease from the original diameter. Thanks, Mike htip://mail.google.com/maill?ui-2&ik=daceaed3O6&view:mDt&lgearrh=inhnyR.+t,=t 7'3 h no A n,. . 2009-08-24 11:39 Black Diamond Firepl 719-293-0481 9704792452 P 2/4 22 jA ' 20 31e• For Uee With B-1 - Vent Pipe 1A'li /r HEAR7NAREA Onl 1 16311' 7- 17 91i" ' t3 314 •~l f OIMENSIOPIS I, T 1 .27'12* 3`'Is' _ 2T 7' mtemets Gas . WITH REFRACTORY Supply Inlbl 1 _~Si.._ ..~5... .t if i. 36 lie is Ife! 321/4' 1 j _ _ _!i I • • - 6 Tle- t0'Iz' I . 8 X14' 1 l 3'I' 8 9le- 1 rl2- 1 .r._ 329 5 2" 2 t le ` 7 °le 2 b: ~13t1:_ 106/ - 16 314, Figure 1- Applienca Dlmonslons 5 wwwAsestech-Coat 100660.OIF sonnuCT sPECIFICATION 2009-08-24 11;39 Black Diamond Firept 719-293-0481 Example 1 shows the minimum allowable system height and lateral offset for a 60° or greater inclination. Code specifies that offsets at 600 or greater are considered horizontal and must follow the 75% rule for lateral to lotal vertical system height. Codes also al- lows only one offset in the total System when at 60' or greater, The io(al vertical height In this example represents the minimum height of 8 feet and therefore the allowable lateral Is 6 feet when the 75% rule applies. If the lateral length must exceed 75% then the system must be sized In accordance with the Category 1 venting tables. Example 2 shows a multiple offset each at 45' of Inclination. Multiple offsets are permuted If they do not exceed 45° of inclination. The total lengths of th two offsets are not required to meet the 75°6 allowable rule, Example 3 shows a single o!fsel at 45° of Inclination and therefore the lateral length at 10 feet of offset does not ha' 10 meet the 75% rule. In each case the offsele must, be supported and flrest0p3 must be positioped wherever the vent must pass through a subiloor, ceil- ing joist or an attlc overhang, The vent pipe must terminate vertically Into a rated type vent cap and extend a sufficient height through an approved roof Mashing, roof jack or a roof thimble. At all points the listed clearances must be maintained, Vent terminations must be Ipcaled In ac- cordance with height and proximity rules of WWII Vent cep j Maintain 1 teU1 Listed 10 NFPA No, 54, These rules apply to vents at 12' diameter or less and require a minimum height In accordance with the roof pitch and a minimum of 8 feel distance from a vertical wall or obstruction (see Figure 10), If venting horizontally through a side wall be- a«nss necessary, a listed thimble approved for use with B-type vent must be used. Cheek wlth your local codes before venting through a side wall, Listed vein coo Frain Roof Real Pltcn X/12 Elated Clearenea Flat l0 6/12 8112 l0 7/12 1,0 - 0.30 Over 7/12 to 8/12 1.25 1 5 0.38 Over 8/12 to 9112 . 2.0 0.46 0 61 Over 9/12 to 10/12 2,5 , 0 76 Over 10/12 to 11112 3.25 . 0 99 Over 11/12 to 12112 4.0 , 1 22 Over 12112 to 14/12 5.0 , 1 52 Over 14/12101 8/12 6.0 . 1 83 Over 16/12 to 18/12 7.0 , 2 13 Over 18/12 to 20/12 7,5 . 2 27 Over 20/12 to 21117 0 . _ . . Figure 10 - B-Vanr Tarmin- Ncns Usted Vent Cap EXAMPLE -2 F/ga►e 9.7yplcal t3-Vent Corrllgurallon I www.dnrateoh,oonr 9704792452 VENTING INSTALLATION Continued l1 Ft. EXAMPLE 3 12 Min. 100860.01 F P 3/4