NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ADD/ALTMFBUILDPERMIT Permit #: 807-0269 (u- -64(5-
Project #: ??
Job Address.: 174 GORE CREEK DR VAIL
Location......: THE LODGE APT CONDOS #530
ParcelNo....: 210108221074??sor 'afi
ohrNER TYTEL, HOWARD & SANDRA 08/17/2007
1OO OYSTER BAY RD
MILLNECK
Nv 11755
APPLICANT BECK BUILDING COMPANY 08/17/2007 phone: 970-949-1800
P.O. BOX 4030
VAILco 8L658
License: 117 -A
CONTRACTOR BECK BUILDTNG COMPANY 08/77/2007 Phone: 97O-949-L8O0
P.O. BOX 4030
VAIIJ
co 81658
License : l-l-7 -A
Desciption:
INTERIOR TRIM, STAIR TREADS AND RISERS, PLUMBING FIXTURES,
ELECTRICAL FXTURES. PAINTING AND CARPET
Occupancy:
Type Construction:
Valuation: $50,000.00 Revision Valuation: ?? Total Sq Ft Added: 0
*:l 't t,|,t** **'l'| *a*:l*
Building--> 9643 . ?5 Restuarsnt Plan Revi€w-> So . 00 Total Calculated Fees-> 91, 065 . 19
Plan Check-> $418.44 R€crealion F€€-t $O.OO Addilional Fees--.--> $0.00
tnvestigalion-> 50.00 TOTAL FEES - > $1,065.19 Toial Permit F€e-> S1,05s.19
Willcall-> 93.00 Payments > 91,05s.19
BALANCE DUE-> 50.00
+r lralt*t *:l* * * *t i + + * f * l * ll a'l *t *'l *:*
Approvals:. Item: 05100 BUII-,,DING DEPARTMENT
08/t7/2007 jplano Action: AP
Item: 05400 PL,ANNING DEPARTMENT
08/17 /2007 warren Action: AP
Status.....: ISSUED
Applied...: 08/17/2007
Issued ...: 0E/20/2007
Expires...: 02/16/2008
See Conditions page of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this stucture according to the towns zoning and subdivision codes, desigr review
approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto.
NEQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOT'R EOT,RSI tN ADVANC
4 PM.
EPf,ONE AT 479.2t49 ouR orT'rcE InoM &00 AM.
SIGNATIJRE OF OWNER FOR HIMSELF AND OWNER
Ir
****'|*+*'|+!i+++'|t**'i**'**:*'|'|,|''|,|'*'*:t,}:|t*'}*****{'t*'t+*****i******{t't,}'t'},}{.'}'|l'}*'}'t***'}||**
Permit#: 807-0269
CONDITIONS OF APPROVAL
as of08-20-2007 Status: ISSUED
****+*'|*+'+'|+*+**'t'}****'|l'{''|''t,}'}:|''|,t*'}'}**'.''t'l*'|'}*+++****i********'|***lt*'t*'t'}**'|t{t,|{t{ti**'**'|*'t**+***************
Permit Type: ADD/ALT MF BUILD PERMIT
Applicant BECK BUILDING COMPANY
970-949-1800
Job Address: 174 GORE CREEK DRVAIL
Location: TI{E LODGE APT CONDOS #530
ParcefNo: 210108221074
Description:
INTERIOR TRIM, STAIR TREADS AND RISERS, PLUMBING FIXTURES,
ELECTRICAL FXTURES. PAINTING AND CARPET
Applied: 08117/2007
Issued: OE/20/2007
To Expire: 02/16/2008
****** *********!F** 't**** * **{"t'}'t**** ***** * * * ** ***Conditions.:1.**'lr'* 'i '1.,1.:* *!*{r '}'}:lr*** **** *** ** * * *** ** dr'*** {. * '* '}'}'1.*
Cond: l2
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLTANCE.
Cond: l4
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: I
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE AI.TY
WORKCANBE STARTED.
Cond:40
(BLDG): (MFR/COMM) FIRE ALARM REQUIRED PERNFPA 72.
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR
F VAIL LDING
Separate Permits are requi e plumbing, mechanical, etc.!
GONTRACTOR I N FORMATION
-s
Vail. Colorado 81657
Bo?.oaag'ffi
PLICATION
Qro-Q..tQ - \go
own of Vail Reg, No.:riuit, hbn\c
COMPLETE VALUATIONS FOR BUILDING PERMIT & Materials
BUTLDTNG:$ 114,000 -ELECTRICAL: S bO) -OTHER: $
PLUMBTNG:$5000-MECHANICAL,$ 6d)'TorAL: g 50,000 -
For Parcel # Contact il""E.S%ffiA' 'F*^\or visit
Fi*Hls zl o I b$ zzlo-1{n U
JobName: Tltt\ fl.trnodc \TOWN OF y61gro.;-*,to'ot,
ftiu H f' $; grc Lr'l*
Legal Description Lot:Block:Filing:subdivision: l,odftt Ap+ 6ndou*j.l
owners Nuru,4n,nd,f TU ft Address: 100 eskr BAl,f lQ ,tvlitlNtcb,Nt Phone:911r- be{_ 0tzO
ArchitecuDesisn"'l fimr DirJ. nrcl Address:pg6o {1zc). Auo'n,[-o B||,brr, ll "non"'rt1D- qq-?bz
Engineer: l.t | 0 Address:Phone:
ry- , t'rk.Tr irvt ,6ttk 'trcads lf\eu<, Ptun^h,v5 fi$.;ra< ,E\ccR'*t.rrrs, Pninhvul , t\xoc* ' '
WorkClass: New() Addition( ) nemoOel t{) Repair( ) Demo( ) Other( )
Work Type: Interior fi) Exterior ( ) Both ( )Does an EHU exist at this location: Yes ( ) No (X)
Type of Bldg.: Single-family ( ) Twojamily ( ) Multi-family 1l; Commercial () Restaurant ( ) Other ( )
No. of Existing Dwelling Units in this building:No. of Accommodation Units in this building:
No/Type of Fireplaces Existing: Gas Appliances ( ) Gas t-ogs /) Wood/Pellql{ ) Wgod Burning (
No/Tvpe of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wqod Burninq (NOT ALL
Does a Fire Alarm Exist: Yes ( ) No (Does a Fire Sprinkler System Exist: Yes fi) No (
*********************************#******t*FOR OFFICE USE ONLY*****s*t**t*rr*********:r**+H:l**i***!r:}************.*
V r a€5.5
http://www.vailgov.com/docs/dl-forms/buildinqjermit-+17-2007.DOC Page 1 of 7 041t712007
li
NinaTimm
Housing Coordinator
Town of Vail
Town of Vail
OFFICE COPY
May 16,2007
Howard and Sandra Tytel
100 Oyster Bay Road
Millneck, NY I1765
Dear Mr. and Mrs. Tytel,
Enclosed you will find a 'till" for your employee housing requirement under the Town
of Vail's inclusionary zoning ordinance. Copies of the ordinance as well as the
associated resolution have also been included. Additionally, a copy ofthe Design
Review Board Action Form has been included for your project. It states that *all
development applications submitted to the Town after the effective date of Ordinnce26,
Series 2006 shall be subject to the pending employee housing regulations in whatever
form they are finally adopted." The Vail Town Council unanimously adopted Ordinance
8, Series 2007 onApril3,2007.
Payment of the fee-in-lieu is required prior to the issuance of a Certificate of Occupancy
for the project
Ifyou have any questions please feel free to contact me at970/479-2144.
Sincerely, ,
tt
Ff*.n'#iipy
Tytel Interior Conversion
Legal Description: Lot A, the Lodge Apt. Condominiums
DRB 07-0005
I. Net New GRFA for Tytel Residence
A. Residential Increase: Inclusionary Zoning
Increase in GRFA : I 10 sq fi increase
Inclusionary Zoning requirement = 10 percent ofnet new residential sq ft
110 sq ft x l0 o/o: 1l sq ft required deed restricted employee housing
B. Possible Method of Mitigation for Inclusionary Zonng
1. Fee-in-Lieu
i. Provide a fee-inlieu payl.ent to ths Town of Vail of
I I sq ft x $236.65 / sq ft: $2,603.15
II. Payment of the Fee'in-Lieu
A. Payment of the fee-inlieu of $2,603.15 must be made prior to the final
inspections for the addition
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S.FRONTAGEROAD
VAIL. CO 816s7
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ADD/ALT MF BUILD PERMIT PETMit #: BO7-0015
hoject#: ?'fpR: O-l -oooF
Job Address.: 174 GORE CREEK DR VAIL Status.....: ISSUED
[,ocation......: THE LODGE AIrI CONDOS #530 Applied...: 0210812W7
Parcel No....: 210108221074 Issued ...: 03/Ul2m7
Expires...: Ogl29l2W7
olrtNER TYTEL, HOWARD & SANDRA 02/O8/2OO7
1OO OYSTER BAY RD
MIIJIJNECK
NY LT755
ARCHITECT I-,ARRY DECKARD, ARCHITECT 02/08/2007 PhONC: 970.559-3102
PO BOX 725
AVON
co 8l_620
License: C000001796
APPLICAIiM WALKER BUILDING COMPANY 02/08/2OO7 PhONC: 970-328-9362
1"052 MESA DRIVE
P.O. BOX r-r.38
EAGI,Eco 81531License: 882 -B
CoMRACTOR WATTKER BUILDTNG COMPAI{Y 02/Oe/20O7 Phone: 970-328-9362
1052 MESA DRIVE
P.O. BOX 1138
EAGI,Eco 81631
I-,icense: 882-B
Desciption:
ADD ONE EXTERIOR WINDOW AND DOOR AT WEST ELEVATION AND IlO
SQ FT OF GRFA IN LIVING ROOM TO MAKE INTO MASTER BATH
Occupancy: R2 Rl
TypeConstruction: III-A
Valuation: $178,000.00 Revision Valuation: ?? Total Sq Ft Added: 0
Investigation- >
will cdl----- >
so. oo ToTAL FEES------------- >
$3.00
Building----> 51,430.55 Res$arant Plan Review->PlanCheck--> i929.85 Recreation Fee-------- >
FEE SUMMARY :i,t'hr*:tr.'i**.t****:******{.****'l.a**r*****!.d,:t*:r:1.:r+,i:F**,},**,****'***{.**
S0 . 00 Toal Calculated Fees- > S2 , 363 .41
$0-00 Additional Fees----- > 50.00$2,363.41 Total Permit Fee----- > $2,363.41
Paynents-----------..- > 52,363 -4I
BALANCE DUE--------- >s0.00
Approvals:Item: 05100 BUILDING DEPARTMENT
o3/o2/20o7 JRNL Action: AP
ftem: 05400 PIJANNING DEPARTMENT
02/08/2007 warren Action: AP Elevations of the
remodel not included. The elevati-ons shall be
reconstructed per the approved DRB application.
Iten: 05500 PIRB DEPARTI{ENT
Item: 05500 PITBLIC woRKS
See Conditions page of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge ttnt I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to cornply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this stnrcture according to the towns zoning ard subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQTJESTS F1OR INSPECTION SHALL BE MADE TWENTY.FOUR IIOTJRS IN ADVAI\ICE BY TELEPTIONE AT {I92I49
AM-4PM.
ORCONTRACTOR FOR HIMSELF AND OWNEF
'**:*****!**'f *******i(*******!t,t'*'*'t!*'t******1.***!t**'r't****************'t*'t******!*****'+{r**'l***'k**!t***:r*'+:lr'lr:*,***!8**
CONDITIONS OF APPROVAL
Permit#: 807-0015 a6ofO3-U2-ZUJ7 Status: APPROVED
{.'f*'|.**'r!N:f't*{.i****'t*************!t*{.**{.{<{.*1.*****'t**,|t'F'i't**'N*,t't**:F*,}*t***:t***,t*******'|*'}'F'|!*:|.********
Permit Type: ADD/ALT MF BIJILD PERMIT Applied: A2l08l2m7
Applicant: WALKER BIIILDING COMPANY Issued:nU328-9362 To Expire:
Job Address: 174 GORE CREEK DR VAIL
location: THE LODGE APT CONDOS #530
Parcel No: 210108221W4
Description:
ADD ONE EXTERIOR WINDOW AND DOOR AT WEST ELEVATION AND 110
SQ FT OF GRFA IN LMNG ROOM TO MAKE INTO MASTER BATH
*****1.***r(:r***********,t{.'lr*:tr********************conditions, {.!r:ir.**:***{.********:*r.'t***********'1.*{r**********
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE.
Cord:14
(BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO
BE SEALED WITH AN APPROVED FIRE MATERIAL.
Cond: I
(FIRE): FIRE DEPARTMENT APPROVAL IS REQI.NRED BEFORE ANY
WORK CAN BE STARTED.
Cord:,()
(BLDG): (MFR/COMM) FIRE ALARM REQLIRED PER NFPA 72.
Mu{
APPLICATION vv|LL NOT BE ACCEPTED IF INCOMPLETE OR UNSI
L
Separate are required for ng, mechanical, etc.l
Project #:
F:ltCine-F,e
75 S. Frontage Rd.
Vail, Colorado 81657
CONTRACTOR INFORMATION
COMPLETE VALUATIONS FOR BUILDING PERMIT
BUILDING: $
For Parcel # Contact Assessorc Otrice at 970-328-8640 or visit
WorkClass: New() Addition( ) Remodet |fl Repair( ) Demo( ) Other( )
WorkType: Interior( ) Exterior( ) Both Does an EHU exist at this location: Yes ( ) No
Type of Bldg.: single'family ( ) Two-famity ( ) Mutti-tumity ff commerciat ( ) Restaurant ( ) other( )
No. of Existing Dwelling Units in this building:No. of Accommodation Units in this building:
GasAppliances( ) GasLoqs( ) Wood/Pellet( ) Wood
: Gas Appliances ( ) Gas Loss ( ) Wood/Pellet ( ) Wood Burninq (NOT ALLOWED
FOR OFFICE USE ONLY
F:\devwRtvls\Permib\Building\buildrU_.f rntt.DOC
il \v/ t5
200t
_VAILOF
lfi) E-G
/'1/ FEB
Towrv
0awa0f5Ege r of 16
..€.
RocrRssonrs
January 4,2007
Mrs. Sandra Tytel
174 E. Gore Creek fhive
Vail CO 81658
Dear Mrs. Tytel:
The Board of Managers for Lodge Apartrnent Condominium Association has received
your request to remodel your condominium. The construction will include the following
projects:
1. Remodel the entire kitchen.
2. Remove all flooring and replace.
3. Remove all bathroom fixtures and replace.
4. Moving walls to facilitate bathroom remodels.
5. Additional ll0 square feet offloor space.
6. Electrical upgrades.
7. Replacement of all windows to match existing.
8. Addition ofa window and reconfiguration ofthe balcony door.
Subject to the following conditions the Board of Managers hereby approves of the
proposed plans:
l. An approved condominium construction document is signed and all conditions are
adhered to.2. All required permits are obtained from the Town of Vail.
We wish you well in your endeavor.
Sincerely,
\/zvo
V. Charles Viola
Managing Agent
Lodge Apartraent Condominium Association
174 East Gore Creek Drive. Vail, Colorado 81657, USA
Telephone (970) 476-5011 Facsimile (970) 476-7425
www.rockresorts.com %fu:
oa(ff.ffirY ElEInFr€ir
Design Review Board
ACTION FORM
Department of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 lax'. 97O.479,2457
web: www.vailgov,corn
Project Name: TYTEL RES. ADDffiON
Project Description:
Pafticipants:
Project Address:
Legal DescripUon:
Parcel Number:
Comments:
Location: THE LODGEAPTCONDOS #530
LODGE AFr CONDO (THE)
DRB Number: DR8070005
Request for an interior conversion of 110 square feet. Includes the addition of one new window
and a window to be replaced by a french door.
OWNER TYTEL, HOWARD & SANDM OIIOBI2OOT
1OO OYSTER BAY RD
MILLNECK
NY 11765
APPLICANT WALKER BUILDING COMPANY OUO8|ZOO7 Phone: 970-328-9362
1052 MESA DRIVE
P.O. BOX 1138
EAGLE
co 81631
License: 882-8
CONTMCTOR WALKER BUILDING COMPANY 0t10812007 Phone: 970-328-9362
1052 MESA DRIVE
P.O. BOX 1138
EAGLE
co 81631
License: 882-8
174 GORE CREEK DR VAIL
Lot A Block Subdivision:
2LOL482-2|074
See Condiitons
Motion By:
Second By:
Vote:
Gonditions:
BOARD/STAFF ACTION
ACtiON: STAFFAPR
Date of Approval: 01/10/2007
Cond:8
(n qN): No changes to these plans may be made without the written consent of Town of
Vdil staff and/or the appropriate review mmmittee(s).
Cond:0
(P|-AN): DRB approval does not constitute a permit for building. Please consult with
Town of Vall Building personnel prior to construction activities.
Cond: 201
"i ol
DRB approval shall not become valid for 20 days following the date of approval.'Cond: 202
Approval of this proJect shall lapse and become void one (1) year following the date
of final approval, unless a building permit is issued and construcflon is commenced
and is diligenfly punued toward completion.
Cond: 113
All dwelopment applicaUons submitted to the Town after the effectit/e date of
Ordinance 26, Series 2006 shall be subject to the pending employee housing
regulations in whatener form they arc flnally adopted; provided, howaner, that if
the Town fails b adopt the pending employee housing regulations by April 75,2007,
this Ordinance shall not apply to sudr development applicatlons.
@nd: CON0008619
The applicant shall reconsbuct the o<terior of the building In a manner which does
make it evident where windows were removed or added. This may entail replacing more
siding than just patching locations where windows were removed. Under no
circumstance should it be distingulshable were old and new materials meet.
@nd: CONffi08520
The applicant shall makh all windows, dmrs, siding, and colors to those o<isting
'cunently on the structure.
Ptanner: Wanen Campbell onS ree paii: g3oo.oo
gLl8612g67 il: el 5L69222748
..F
".tgn ti4 oz oa:asp 61ry g' welk*
PAGE €I
9?0 328 70{6 P,z
*ffi Addltions-RecHential or Conmetcial
Appllcation for Decftln Review
rErnmefit of &ilm'nq DetteloFtr|ert
zs soin Fontage nor4 \r.1, Colorab 81657
tck gtoftgJtlE * 970-479'2f9
rdt rflil.n[gsYcoftt
G.nar.l DtlbnFauolG
Al Ororrct3 rquirttg ddgn t€lrrcr mld r€elE 4rord P|fr to $ht|thg a br$tng Arnit npdiefen' Plese rrE to
ti-s-ri:umiuf--rhurtmris O rnc pl,ira|ar rpiinar d* is t€qresllrt' -rn fdicaton tsroElgt .RtF Gff+-I
*idJ u"tr 6f,-1aqr1g rnnormaUq, s rccEtt d Dry 6c Consnunni oet1g6p?tpnt D.perttplt' Th' goln maY cro nGed
iid'circ;brt[ra,"c",ffi;;4#ltaEni"rs-rrl'illlu;r'r"mt-qryg-11g1151'Prtlt'dl'pc'l;"Hil;iLfi;F'fri ;" *r.d eicorur..trrn connrqrccr rltrn qrc v*d tlr.prrc1a1
tiqrtption of t'he RcquctG
Locrtlon of the f)l!Pos* Lot!--Bl6k:- SuHMslf|:
phr*drdd,*ra: /?u f<<+f. r t 2.*Ah,;/6a' 8' 1-
parcef ilo.! HhlOSTl tOZy.- (coilrct E eh co. r5scsorrt e F32E€5{o til oarel no')
Zoolng:
ilrm{r} of olrnc(i):
ilallingtdll]erc
Orrmrtc) Sign tr€(s):
ilame of Applhantr
r*.iltng Add]Esi:
E-rnafl Addr.s6:
. )hcfrypGof Rdicn-dtr Signs l$ Plllsfl.m prqtarclbotdtotrldgn ft1
No FeeCo(rFdnel,hr
ileflCooruudrt
Adddar
t{nor Abnrgon
(multi{r milyrcomnHci.l)
lftorAbattor
(ningbhnily/dudcO
ChrrErs b Afrovcd Plans
s€fandoo R*ucd
lEsotxlo
s250
tr
tr
F
o
For @1$uc0m of r flsf ltttdhg or derm/r€hld.
For an ddison wherc rquaE foo@e ls adfu b rny rc$tlenthl or
conmadal ilflding fn fiftt 250 addltirs e itmlta csw.erdons]
For mlnor dlragca tr arflngE and Ctr imF6rEms,rts, $ch .s,
rgrbofhe, Finting, wlt|(bt, Udfions, lan6caplng, ftnes and tttnning
wall+ !tc.
for nrr,oi aarEcr b hffhos ard rfte impov:nrcnb, s-dr s,
r€-mof/qg, gdnrrg, wtr*nr .ddto|q la&caplng, tiaas and nithingt20
o
o
wollt !tr.3:10 hr rcrtlons b pb|E dre.dy rppro,ed by nanning Sldlt or tie DrCannrr,h{ld.ib Fr
tue ftittl
-i--
chcdr ts.:- ey:t
ASBESTOS TESTTNG REQUTREMENTS
THE TOWN OF VAIL AND SrATE OF COLOMDO DEPARTMENT OF PUBUC HEALTH REQUTRE ASBESTOS TESnNG
ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL vyILL BE DISTURBED OR REMOVED.
AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPUCATION
FOR ALL REMODEL ADDMON OR OTHER PROJECTS INVOLVING ANY DEMOUTION OR REMOVAL OF BUILDING
MATERI.ALS THAT MAY CONTAIN ASBESTOS. BUITDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE
NO ASBESTOS CONTAINING MATERI,ALS ARE EffMPT.
A COPY OF fiE REPORT MUST BE SUBMTTTED VVTH YOUR BUILDING PERMII- APPLICA]ION
o I have included the asbestos test and report with my building permit applicauon
o I certifo my project will not disturb or remove more than 160 s.f. of building
plans submitted with my application clearly indicate this information. (t-his will
review, and will delay your project if found to be inaccurate)
material. The construction
be verified during plan
applicant signabrre
OR
date
o The building was constructed after October 12, 1988. The date of construction was
original @nstsuction date
applicant ggnatire
F:\cdev\FORMS\FenniE\BUlldng\bulldngJremit. DOC
date
Page 4 of 16 021o}.12005
llEC I t 2OOB l1:29R]{ BOULDER EilvIROltl{ElrTRL r (966) 699-+121 p.3
MMht
Boulder Environmentel Management, Inc,' SDc.rTtrilndDorldcr,GOlB@
Ptore Sm;a91115 Frr: t ([6Q691]{(ll
Deccmbcrll,Zlx|6
Watkcr Building Company
Mr. Gay Walker
P,O. Box ll3t
Eagle, CO 81631
RE: Bnlksanplingofsuspcrfeita$estos-cominingmanrials
Thc Lodge ar Veil, Udl53& Ydl Cclorrdo
DerMr. Walker:
Attactred is tp report for lhe asbcstos survey md bulk rynpling of suspecEd asbestos-
conainingbuildiry mEterisls atThLodgc rtVd[ Itria 53O,Yrfl Cobrrdo
This iwtstigatimwas coducted onbebalf of nd for tre enchsive use of Stdkcr
Building Conpruy (clieol), solely fsrxe ina limited asbcstos srwy of thcpropty.
ThirEportudtbe findflnphcrehqhdr pg inq,ho! uinpa! bc dis*minedc
convqpdio ay othcr party, mr uscrl by my other pa'ty, inu,*rolc or in part without
prior writta crrcent of Bortdcr Environmcnlal ManagcncnL
Thc rcmlfs ofrlri-r srlwy sp lini1ql15 neqidrrh4 wrc rersablc end fucseeablo.
Additionelmmials may ais bchind bsd sufrccs Prtsmd knowlcdgcable of
asbeos cutaining maerids should alwayr ovprsce dcmolitiq activitics. Danolitim
u,ork shild bc bttod and rqling pafrmrcd by a crtc of Cohndo licosd hrildiryiryclor if additional rrafcridA wldrfi arc nxpctcd of oontaining asbcOq re
reotmered-
If you havc any $rctiu reguding ts conte"rfs of tis rcporq plcrre do ld biEe to
conlact us-
SiFEly,
C,L/I
Cluis Maron
nojctMnrgcr
*ArbcrtorrldrlEdufhf llyEi.ocrSdcty.Find Air TcrtingrrHcdil end $fcty Tnldlg.
DEC II 2OOG ll:29R]'l EOULIIER EllvIRONllEltTRL I (AGCI 599-.+l2l
Boulder Environmental Management Inc.
5Ih€rTrail RodBonl&, CO t03@
PhodE: (303)'14$1175 Fn; t (166)699{12l
BULKSAIUIPLINGREPORT
Thc tadgc et VrL Unft $q Yril Cebrrdo
Iniroductirn:
On Deceobcr 5, 2m6, Boulder Envimnmcubl Umagpmcnt, Inc.'s building inryector,
Cra[ Rcu" coducned bulk samnling of srsueed asbagtos.oonfid4ips naEriEls tmder
tbe diredion ofour clie,nt.
SenpEng:
Duing the sampling Flocess, srspcct ACM was scporaed info three EPA categorics.Tb c*egodo are thcrmal systcm insulaion (TSI), srrfacirg ACIIA ad mirccllmeous
ACM. TSI incMes all rqahrirls us€d to trevcd H los c g8in or xlalcr cofusrtion
on rchurical syseins. Bxmptcs of TSI re pipe mvcrbgs, boiler insulatioo, dnct
wrry, d mud pacted fining mcot Surfrcing ACM inchdes all ACM thst is sprayed,
trurcll€d, or othaurise applicd to a slufacc. Tbcr rpplicnbns rre most commonly used
in fingoofiag, dccoriati\re ad ror(ical Aplicdios. lvfisccUroeous dcrhh imlud€
all ACMmt li#d in trcthermd sysEn insul*ion ote!ficiagcategorieg such as
linolan, viryl asbcstoc flociry rrd criling tilc.
Boildtr Envftomcolal },fasgEetd, Ioc- folloxrcd EPA rtcqrcded qlhg
guidclincs for identification of asbcstm in bulk nroiccs. A sst of th,cc (3), ftrc (5), or
scvco (l) sanples nqe collc@d fcerch nmiel typc adsnalfed by Polariad Light
tvtluoropy @IJvfI F{Eh s1qryrb $t EsJptemg[icrly Edfa{ tho dcmiUbn
that a sample in a set comid asbcstoc, Esb6is of 6c rcmshing sunplcs in thc sct was
discoutimcd. If m asbcsma *rs dccctcd duing th ulys, fu sspcc* maUial was
dctcmined to bc rcgtive for asbestos contcot
rArbcils'LcldrlndffilEy3irc AfoTcdiryr*Hcelh eld Sefcty Treinhg*
P.'f
Boulder Environmental lvlanagcment, Inc.
Rcmlt:
The following mdcrials urcre amlfrad ad daetmid to bc asbcsoecontaining utilizjng
poladzcd [ght microccopy (PIM).
compositc porccntage drywall system is one percent rsbestos or
Rcgulrtay agmcits comider dr5rrnlt md joir coupouod e fnish rysfro lhat is e compocits of
both building mrtcrhb. Thc two s|tbFrts, drJrsrall sDd joint oomipund arc anlji'zd sqan0ely
for rcboe. If e rnbport conAinr asbestoc, th@ thc ovErdl .$bcstos ooteot of the comtinoa -
$rb-Fr$ b u$d to d€fiormirc fu hrad cbssification of &y*rll and jcint conpound as a
sys&E-
Tho Ervhoncntal Mion Agacy ud ttrc *c of Colmdo Dc4artnart of hrblic Hcalth rnd
Ewironnoat do not rwulttc drywdl ard ioint ccupound thd hevc ra ovcrall asbcdos cotout ofl7r s lcss. Howevcr, OccupafioDrl srfctlr rnd Horfh Adninistntioo rqul*iw epply to*oterr hrndlin8 thc mricrial
Tbc following mrtcrials rrcrG amlred md daernincd to bc trace a$cstoecooiaioing
utilizing polrizcd ligbt Eicroscopy eLM).
TRACE ASEESTO$C{)NTAINING MATERIALS
The follcrring maHials wErc aDslrred md daernid to bc nm cbcstos.cmtrining
sfi lizing poluizrd li glrt microsopy (PLM).
NON
'Arbertorrleedrlnfusbid Ilgirocrsrfcty*Fird Air Tcrting*rllcdtt rndSddyTnhhg:
ASMMATEnIALII
MATERIAL SAMPLELOCATION SAMPLEII'CONTNNT
Drywall joint
compound
Ivlaster bedroom -north wall l2-6-CR-03A|,3% Chrysotile
rThs ovorall of asbestos
MATERIAL LOCATION SAMPLE II'
Windowglazing Westwindows t2-6-CR-07C
r2-6-CR-08C
l2-6-CR-09C
AININGMATARHI.S
MATERIAL LOCATION SA"I}IPLE ID
Mastic lo floor bathroorn
ld floor bathroom
l* floor bathroom
l2+cR-048
l2+cR-058
t2-GCR{58
DEC ll 2OOG l1:30f,ll BoULIIER El{vIROniEtlTFL r (AGGI 69S-+121 p.6
Boulder Environmental Managemeirt, Inc.
tu* i,BlH'H'd "*Hfiffi ,-n, r,
DisculEior:
Sanple analyscs tesults are rqnrted in per,ccatrges of destq ad nm-asbestc
conponc,nts. The EPA defines rny mderial thd,codains greater than one perccnt (l7o)
asbcstog uili-ing PLM, as being m asbe*os containirry mauial. Miterials that are
idcotified as bn deac.tcd" arc specifu rs lot contaidtg r$cstos.
Cone.lqrion:
Thc joint conpornd on th dqmdl jointconpond rylicil ud thcrindcr 3|uirgcontdnr one pcncctrt sbcrtor or lcss.
.The deurolition r€qdres OSHA catcCry 2 asbesbs r@oval wuk practices. It is
rcconmended ftata li;cdasbcstos abatcocu couFrtabc rctaincd fq t[is
demolition to omply with osHA roquircments regrrding the dcmolition of asbestos
oonaining materisls that conlain lesr tha l% asbcsbs.
The OSHA rcgulation 29 CFR 1926.1l0lfuXlxii) and (;ii), ar urell rs rccord-&ecping
rcquirocnfr under 29 CFR 1926.1 lOl(n) thet ue arsocirfed with tbe cgative exposure
asscssmenl ryply so long as ncilhr asbcstos pcrmissibh cxposurc limit (PEL) it
cr(occded or Eight be exoccdcd-
29 cTR 1926rl0l(gxl)Qi) rcAdrcs:
"Vct methods, or nn{ting agents, to contol eorployce Expo$.trel during rbestos
hNndlin& mixin& rcmoval, o{ting qdlc*ion, andclcanri, cxc€ptc,tere employerc
dcnmstrde th"t tbp usc of wct mctbods is idcasible dw to for exrnplc, fu crcatiqr of
elccicd hazrds, cquipm.ot rnlfimio, rn4 in roofing, orccpnasprwfub in parrgrryh
GXt)Gi) qf this stiur;"
@d 29 CFR 1 926. 1 l0l(gxlxiii) r€qutu€s
'?rompt chaarry sDd dispost of vnstcs md dcbris coilininatcd with a*cstos in leak-tighcffiincrs qccpt inrcofingopcr*ior, uhcrc tb gocedus ryodfied inpurgr4h
GX8)Gi) of this wdm qrply.'
The reulrs of this survey pe*tain orly to nitcrials tcstod- Thc labofioryrcpqts
sryputingthc findingc at atlachcd Appficablc stab. fcdcrrl, ndlocal cnviromenlal
rqulaims stipulme th* mly a licecd arbcstos rbo!€mcnt coruactor sbuld disMb
sbcrtos cortridlg Eeilk
*Arbcrtocrlad.hdrrtirl Eytlac.Sdcty*Fild Ah TstbSt*EcftudSftyTrftirg'
DEC 11 eOoB I 1:3ORll BOULITER EtlvIROlltlEltTBL
:
I (AA6! 699-+la1
Boulder Environmental lvlamgcment Inc*[ffi,X'*hf,ff*no,
Please mdact Boulder Enviromental Mmgerrcd, hc. with any qncstiurs or crrrccms
rcguding thir report
Sinccretn
Chisli&ron
ProjectMaryFr
' rArbgtoc*Lcrdrlndurthl EghcrSefctyrFiul Air Tcting**Ilaf,h rnd SddyTnhing'
?.?
DEC l l 2OOG l 1:3OFl'l BOULIIER ElMROt'lt'lEttTRL I (466t 699-{121
Craig Renz
S Detr fteiil Roe4 Borldcr CO 80:f{t3
he n+er&lb conpletd thc EPlt Col*do Apowd IIIELA
ASBESTOS BUILDING INSPECTOR
INITIAL COUR$E
For prpoeas of rccridit tton r€Cuu€d rrndar S*otioo 206 of the Toxic Subit*oscs Cqtrol Act (fSCA)
And tlrc Colorrdo Dcpnmant of Public lleahh srd Environrwff Rcguhion #t-
Conduaed $,
MISER$ INSPECTION & TRANTYTNG, INC.
lE25 West BakerAve. - Englewood, Colorado tOl l0
(303) v22-8E21 Ofilce (303) e22-0124 Far
Course lhe: $eptemher 2S.?7, 2006
Tbis sour$ has becn
granGd approvol by:
EPA Rcgioni VIII
The $tate of: Colorudo
ABIT43469-{X
(,l*tifbutc N smb€t
$eptcmber27'-2W7
Expirur on abovc Dac
trtmo
N
oo
td(rt!3
tdoc
Erflxt
|l|z
ttoz3mz
Dt-
ooo
o
ao
@
II
N
!
@
DEC 1l 2OOB I 1:34H){ BOULIIER ENVIROII}IEI]TFL
ion$.gl0f,oi*F!R$T
GOLISCTED*}:
RTfiE||tilDSY:
r rs66) 6s9-4121 P. ro
RESERVOIRS EI{VIRONTENTAL, INC.
l'lVLAP AEs!f,ed L*orrbry t lOl8SA
TDH Lbnted Labo.rbry, 30i'l:15
TABLE PLTI BULK AI{ALYSIS, PERCEIfTAGE COI'POSITION BY VOLUTE
Pqe2ol2
trtm
Noc'o
IJ{t3
RES Job Number:
Cllcnt:
Clent Prcjecf Numbcr / P.O.:
Client Pmjecl Dero.lplion:
Dal,e Sampleo Recslv.d:
Analysb Type:
Tumaround:
D|teAnalfred:
RE8 tt3glr-l
BouHcr Envlrcnmadrl rrn gcrnent
Itlono Glwn
Lodgc rt vr[, Unh !i10, Vrll
D.c.mbrr 6, 2006
PLI, Shoil Rrpoil
24 Hour
Deocmber !, 2O06
Andyrt RSU'
t!
r
mF
fiz
lino23mz+!r
ooo'
otto(o
Ia
N
ttW
=:--hq !
N
A
Y
E
I SubPhysical I PadDescriplion | (%)
t2s4R{{A
124€R-0:tA
lr{€R{tA
la84R{/tB EM 699097
6eeogE
699099
899100
699t0r
699i02
A
B
c
A
B
AI
c
A
A
A
A
A
A
\Mrib plaster
vhit€rssam plast€r
TanArfiite dmrall
whlt€/cream plasbl
TarJVirib d4nlall
lMrilo plrrter
Vuhrcrcreem plsEr
TanArltritc drywai
Gray gr.nular pla3lar
Gray grailIar pbst€r
Gray gmnular phsbl
Cream glara w bEu,n palnt
Cream gbze w/ brovrn painl
Crcam glaze d brown painl
30
35
35
15
E5
33
33
34
100
100
100
100
100
1m
ND - No.. Ddrclod
Tl - Trs, < l!6 Vinsl Errinub T|E||},Ad. Trlr\dlc'^de|o|b
DEC r I zOoE I 1:3681'l BOULITER El{vIRO?{I.IENTFL I (456) 6S9-+l2l P.lr
P.gc I ot2
2059 Brrlnt SL Danvar, CO 8021'l
(crs) 90+19S6 Fsx (fu) 1714275 Toll Fr€e (066) RESLETW
Ilsnbar8.2ffi
Crui!Marcn
Eonldcr Eruttmmenid Menagsnent
5 DeerTril Road
BorIdsCO8Gm
Deer Cusb|rEr,
Re6ervd6 Envirmmental, Inc. ls an analytkal lebordry acctcdiEd for the amlysis of lrtsttotid Hydene
and Envtronm€ntal metrlces by lhe Nationd Voluntary bborebry Acct€clfiion Ptogram (NV|-AP), Lab
codc | 101696 and the Ameft5n In(tl8tial Hygiene As3ociatbn (AIHA). l€b ]D 101533 - Accreditrtion
Cen|ficalc tt0tt. Thic laDoEto.y b ciltl€.tty ptdrdefit ln bdt Plddency Tes{ng and PAT prcgrams
Espcdlvsly.
Ressnoitr Ervilqmcntal. fr. hl ru|;.ld Up ftilorilE srCG for etolb oonbnt a Fr lotr
|!qu.d. I|! rnrlllsh hs bsr odacC h g€n rd .@fltnca rilr tt€ dppropdatc mclhodology as
drlrd httefrdred erShfifr.Thctlsrb haF b€Gn a.omitHbyouroffE.
RESltll981-l lsthejobnumberGsignedtoUisltudy. Thlsr3pdtisconsldor€dhighlyconfidentisl
and he sdc prcperty of tre orstomer. Rererudr EnvironnEnhl, lrrc. will nd discil$ ary pen of tlls strdy
u,ith p€rsonnelofter han thos6 of the client. Tho r€sults d€scribcd In tfils rEport only apply lo the sampl€s
anatyz€d. Thls Eport mud not bc u!.d b claim cndorsemont of produdt or analy,ti.al lgsunB by I{vlAP or
any'ryncy oI 111e U.S. C;overnment. Thb report *ratl not be repmduced excepl in lull, wilhout wrlten
apilrovat lionr Ree€rvairc Envircnmentsl, lnc, Sampl€s will be disposed ot atler sixty day€ tr|l9ts longcr
sia6ge is rsqucted. lf you have any qrnstions about thb t€po4 plcete f€€l tree b call 30996t1-1985.
Sincercfy,
Jeanne Spenccr Orr
Pr6ddent
Aoaly*(s):
l,.Donbrt cod.r
Srtconorct llufib.n
bborr[ory Rcpott
ftoJ.ct Drcnpuo||:
RE3
XA
RE8lt3ell-l
ffoor Onur
t'o|h. rtvrl tlrlt D!0,
Yrll
Paul D. LoScalzo
Paul F. Kn.ppe
MifidScdct
\ilbnlong Liu
REh Ylbgrzytl
Bil To
\t'alkcr Building Conpo, y
Gry Walkcr
P.O. Box I l3t
Eaglc, CO t 163l
Date Invdcc #
tu)m6 4531
Sl*p To
Walkcr Building Corqmy
Gary f,ralker
P.O. Box I l3t
Eaglc, CO 81631
PO. Number TemB Rep Ship Via F.O.B.Prqed
Not 30 tU9./m05 lodgc al vail #530, VEil
Quantity Item Coite Descdp0on Pdce Eadr Atmunt
I
9
ritc visit S200
Bu&acbcsbs
Sitc vicit by I strte cfColorado c,atifiod arbestor hryector,
incMcr building daaarrizarion, npqt writing, tavcl to hb
hrlt sarplcs andyzcd by polrizad light mlroacopy, EpA
Mcftod 6(X)iR-Elll l5
300.00
25.00
300.00
n5.00
Wo now scccpt crsdit crdt Total ts2s.m
Floor Live Lood 40 psfFloor Deod Lood i5 osfWind (3 Second Gust) ---- 90 mph (Exp. B)
le'smi.c..Design Cotegory --- EXEMPT lieC rOr+.r.r;IBC Edition --- 20Oj : '
STRUCTURAL WOOD FRAMING:
o. Except where noted otherwise, oll 2" nominol lumber, except studs, sholl be DouglosFir-Lorch ff2 ond better.b. Studs sholl be Stud grode ond better Douglos Fir-Lorch or Hem Fir.c. Built-up posts sholl consist of Douglos Fir-Lorch or Hem Fir fi2 or better 2x4 or 2x6studs per plon ond sholl be noiled together with 2 rows of 16d noils @ 6" on centerolong eoch stud.
f.
Built-up beoms consisting of multiple 2x members sholl be noiled togeiher with two rowsof 16d noils spoced ol 12" on center, or with two rows of 1 /2" diometer thru-boltsspoced of 24" on cenrer.
Ledgers ottoched to mosonry wolls sholl be treoted Hem Fir #2, or if LVL moteriol isused, sholl hove o continuous woterproof membrone between ihe concrete ond the wood.Lominoted veneer lumber (LVL) sholl hove the following minimum properties:1. Flexurol stress ---- --------- 2600 psi2. Modulus of elosticity - ],9OO,OOO psi3. Tension porollel to groin j E5O osi4. Compression porollel to groin --- 2Jl O osi
? Compression perpendiculor to groin (porollel to glue line) --------- 750 psi6. Horizontol sheor ---- ------'--- 2g5 bsi
7. Connection of multiple-member beoms:A. Side- looded beomsi) For two or three member beoms, noil eoch member to the next with 3 rowsof 16d noits ot 12' o.c.ii) For four member beoms, bolt through with 2 rows of 1/2" diomeler bolts ot12" o.c.
Aff f umber used in construction sholl hove o moximum moisture content oI 19%.1. Floor Construct ion:
A. Provide 3/4" thick APA roted Sturdifloor roted of 24" o.c., tongue ond groove,
exposure 1. Glue ond noil ponels to oll supports with 8d noils spoced ot 6" olongponel edges ond o_t 12" olong intermediote supports. lnstoll sheothing with longdimension perpendiculor to joists ond end joints stoggered.
GENERAL REOUIREMENTS:
o. Structurol erection ond brocing: The structurol drowings illustrote the completed structurewith oll elements in their finol positions, properly supported ond broced. The controctor,in the proper sequence, sholl provide shoring ond brocing os moy be required duringconstruction to ochieve the finol completed structure. iontoct itructurol engineer iorconsultotion (not in controct) os required.b. Existing structures: Controctor sholi be responsible for verifying dimensions, elevotions,froming, foundotion ond onything else thot moy offect the w'orti shown on the drowings.Underpinning, shoring ond brocing of existing siructures sholl be the responsibility of thecontroctor.c. Dimensions: Check oll dimensions ogoinst orchitecturol drowings prior to construction. Donot scole drowings.
d. Construction proctices: Generol controctor is responsible for meons, methods, techniques,
sequences ond procidures for construction of this project. Notify structurol engineer of
omissions or conflicts between the working drowings ond existing conditions. Coordinote
requirements for mech onic ol /eleclricol /plu mbing penetrotions through structurol elements
with structurol engineer. Jobsite sofety is the sole responsibility of the controctor. All
methods used for construction sholl be in occordonce with the lotest editions of the
tBcltRc.e. Detoils not specificolly shown on the drowings sholl be constructed in o monner similor to
the detoils thot ore shown for like conditions. These items sholl be brought to the
ottention of the structurol engineer os soon os possible for opprovol. Approvol sholl be
f.
ob toin ed orior to instollotion.It is the responsibility of the controctor to contoct the structurol engineer of the
oppropriote time to perform site observotion visits. Observotion visits to the jobsite by the
engineer ore for determinotion of generol conformonce with the construction documents ond
sholl not be construed os inspection.
Though every effort is mode to provide o complete ond cleor set of construction
documents, discreponcies or omissions moy occur. Releose of these drowings onticipotes
cooperotion ond continued communicotion between the controctor, orchitect ond engineer to
provide the best possible structure. These drowings hove been prepored for the use of o
quolified controctor experienced in the construction techniques ond systems depicted.
Town of Vail
oFpnr* qflPY
9.
d.
9-
E
@I(\|I
Nool\l
tt)(\I
v,
N
x
!{
cn
=EFvr
t\lv,
FIoot\o
ctrcEo
=ltlofflIttr*
(g
(uE!
J
Ctrrct
ot\ov)IL
=19
=o
- odl
JAN 2 5 2007
JL 4x4x1/4 w/
(3)-1/4"6x2 1/4
SIMPSON TITEN
SCREWS IN EA.
ANGLE
EDGE OF NEW
OPENING
CMU HEADER FOR NEW DOORS (3'-O MAX WIDTH)
t3I :$::dii
3;EAi,
;! E !
8E::iJt!.
oaE
-A-v-Ho,-rFO.'-. ;'l 6l( !' t<bv>H;
.O(J(U:j
F'dOH>I aotr1
I o\
&cacd byJE--
cor,r ry ---4!-d.ttd bt
-
isad
PER'r'tl 01/23/01
*'=,-
JoB 10701-03
PLAN
NORTHSEONDooRfRAMING PLAN
PLAN NOTES:
1 l99ls-B^+o_w_(_oRlG!NArtNG FROM THrs LEVEL oR ABovE) ARE TNDTGATED: tSINGLE STUD TRIMMERS THAT DO NOT REQUIRE ELOCXINd EELOW INE rI,rbrCFrCO. I2. ALL COLUMNS ARE LABELLED AT THE TOP.
3 (ryL.IlO9B SH-EATHING IS 3/4'' TONGUE AND GROOVE APA STURDIFLOOR, EXP.I, SPANRATING 24 O.C.
4. WOOD BEAMS AT THIS LEVEL,EXCEPT HEADERS, ARE FLUSH WTH FLOOR JOISTSuNLEss NorED (DRoppED).
S. "O" INDICATES coNNEcTIoN TYPE _ REF. SI FoR SCHEDULE.
6. ALL (N) FLOOR JOISTS ARE 2xE's @ 16" O.C.
(E) REFERS
(N) REFERS
TO EXISTING CoNSTRUCT|ON (* - - - - - ),TO NEw (
NOTE: (N) HEADERS FOR INTERNAL AND
EXTERNAL NON LOAD BEARING WALLS
SHALL BE (2)-2x10's w/ (t)-2x+ TRTMMER
AND (1)-2xa KING STUD @ EA. END.
SCALE: 1
2xE LEDGER, FASTEN
T0 cMU WALL W/
1/4"o x 21/4" IfiEN
MASONRY SCREWS,
TYP.
1/s1
JAN 2 5 ?007
NEW
CMU
OPENING IN
WALL, SEE
8" CMU WALL
(vERtFY)
=
Itt
Ft
F{
l\ooa\l
Itta\
({vl
T\x
d3E'FU'
(\v,
(a1oot\o
E'r.Exo
tnoFIto+
IE
ru(uolEoJ
Oro
oottt|cL
=I
=o
tf--r;--:\--n11 ti '\\ pl
'rl -L'- - -!: l-]
[:
tl_---.r-|
tl--tt
t:
N
l-
IGl rN
EEE
I
I
ltN
),
i
I
'ENI
)v.E)VE
I
-j=-r-
,tiNEWiOP
WALL (ABOi'litil
::lT --\-
;\qMU +
1,/s1 ,ti
:iT I
Ih-l'l
mllr -
lg-
tltl
riF
ll'itrrL'-li-ir
-f
I_r
I-T-
alFl
ol]_al-lr
IJ-
II
s
lr,-"'....'1..{
ir'/7,q1 i\!l
J)
+
r\x*
r.)
c\o
i---L----.':---r-- !--CONNECTION SCHEDULE
@ SIMPSON LUS28
@ STMPSON HcU57.25l8
o SIMPSON LUS46
o SIMPSON HU48 w/ (8) l/+xt 3/+TITEN MASONRY SCREWS
ii*Sidlt
r;ggg
5g?i
!iii
Ocrq.rL() -:thxHo
'-rF!.- ;'! 6n(v irA>trr:-.t3
Ei,;
rE*
QOEI
qx
drdgrd b;JEl-
corr ty -.J9!-.n .bd bt
-
bt ait
??evtl d f23lo7
S2
Joa ro70r -o3
TowN o. voir FIRE DEPARTMENT
75 S. FRONTAGEROAD
VAIL, CO 81657
970479-2135
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT
Job Address: 174 GORE CREEK DR VAIL
Location.....: THE LODGE APT CONDOS #530
Parcel No...: 2lOlQ822lO74
Project No, -7RTO 1 - OOOCT.
Permit #:
Status . .
Applied .
Issued.
Expires .
AO7-Cr,32 3O1- od t5
. : ISSLIED.: 0412712W7.: 05lIU2m7.: ll/O7l2W7
OWNER TYTEL, HOWARD & SANDRA
lOO OYSTER BAY RD
MII.,LIiIECK
NY 1_L7 65
AppLreANT STMPLEX TrME RECORDER COMPAIIo4/27/2007 Phone: (303) 355-0500
6240 SMITH ROAD
DEI{VER
coI_,oRADO 80216
Lricense:105-S
CONTRACTOR SIMPIJEX TIME RECORDER COMPANO4/27/2007 PhONE: (303) 355-O5OO
6240 SMITH ROAD
DEN\TER
coLoRADO 80216L,icense: L05 -S
Desciption: ALARM REMODEL OF UNIT 530
Valuation: 32.800.00
FEE SUMMARY *rt*tr*t'r*'l'l***+l.**'***r.':'r******'r'r***'***x.'r*i.*t(*:r*'.**)i***rtr.'t****
04/27 /2007
Elecrrical----- >
DRB Fee---- '>
Investigation--- >
Will Call----- >
TOTAL FEES-- >
$0.00
s0 .00
s0 .00
$0.00
9337.00
$337.00
s0. 00
s337 - oo
s33?.00
to. oo
Total Calculated Fees- >
Additional Fees------ >
Total Permit Fee---- >
Paynrents----*----- >
BALANCE DUE-----.-. >
Approvals:
Item: 05600 FIRE DEPARTMEIflT
O5/O3/20o7 DRhoades Action: APPR Approved as noted:L. one set of stamped, approved plans must remain on-site.2. I-,ocation of smoke detectors on second level, in relation to slope of ceiling,
may need tobe changed. tunount of slope not noted on plans.
CONDITIONS OF APPROVAL
|*'|:l**+***'|'}******'|***:}*:|****'t*|,l**ti*|.*t++**l.{.**{.{.*l.{.l.|+|t+**ti|l+****|i.**:|***t****:|***+***|.++******
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto.
AM-5PM.REQUESTS FOR INSPECTION SHALL Bf, MADE TWENTY.FOUR HOURS IN
CTOR FOR HIMSELF AND OWNET
APPUCATION VYILL NOT BE ACCEPTED IF I]{COMPLETE OR
Project #:k*e3a Building
Alarm Permlt #:
75 S. Frontage Rd.
Vail, Colorado 81657
COMPLETE VALUATIONS FOR AIARM PERMIT (tabor & Materiats)
FireAlarm:$ Jtf.,f;
Fire Ala rm C.ontractor:
),,rlo lt r /r ^....,.r,rii,
Fax#: ].., i. ?Sl -L)L,, t:
Asrewrc Offrce at 970-329-9640 or visit for Parcel #
Job Name: ,
c,cl1e G"l- y'.-ri I vn, f SJ c)
Job Address:ll'l Ltc..r CreeV-D.
Legal Description ll Lot: ll Btock ll rning:Subdivision:
Owners Name:Address: vAf|. F|pc UEDAQrAaENT
Engineer:Addressr H'rgl!3*tr
Detailed Location of work: (i.e., floor\tii i t.- loova ro,-; t \
Detailed description of worlC
fe,n;J(, t r.q U,r,' f 53 C W. flqt r'a, Armn
WorkClass: New() Addition( ) RemodelM Repair( ) Retro-fit( ) Other( )
Typeof Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Otherf{
No. of Fxisting Dwelling Units in this building:No. of Accommodation units in this building:
Does a Fire Alarm Exist: Ves (.() No (Does a Fire Sprinkler System Exist: Yes K) No ( )
***************************************FOR OFFICE USE ONLY*************************************
t t. Y rarir r Lr-tr.
-: -L,' liPublac:WaViPennitFiiie:,*,:]i,ri*F*r1 A*oa"OBv!.+;;,-+:.,^,1ffif.','- t li rl
2 J PR zo 2007 lU,
I'
&(; ie il tV t- fr,r1 ll ii;IAPR 26 2007 ll /ilullt 2-- aJ
F:\cdev\FORJT|S\PERl4m\Fire\alarmJerm-12{5-05.doc pagelofs i IOW IL
tqca SIMPLEXGRINNELL
5240 snith Rd,
Denver, CoLorado 802L6
www. s i.mtr>l-exgrinnel-7 . com
TeTe: 303-355-0500
Fax: 303-355-0675
Fire &
Security
SimpIexGrinneII
Lodge at Vail
Unit 530
174 Gore Greek Drive
Vail, Colorado 81657
VAIL nAE DCpAnT,f{tNr
htn
uh
r llrtfbl o
TYPE:
$implex@rinneII
6240 Smith Rd
Denver, CO 80401
Sales: (303) 355-0500
Service: (303) 355-0500
Fax: (303) 355-0615
DESCRIPTIONT
4098-9714 Photo Sensor
4098-9733 Thermal Sensor
4098-9794 Sensor Base with Sounder
4905.9942 Sklrt for existing speakers
S,Simplex
UL, ULC Listed;FM, CSFM,
and MEA (NYC) Approved-
TrueAlarm@ Analog Sensing
Sounder Base 4098-97941or use with
TrueAlarm Photoelectric, lonization, and Heat Sensors
E@
Modular TrueAlarm sensor base with built-in
electronlc alarm sounder:
r Piezoelectric sounder provides high output (88 dBA)
with low cunent requirements (20 mA)o For use with interchangeable TrueAlarm sensors;
photoelectric, heat, or ionization (ordered separately)
Sounder operation can be:
V . Po*"rrd from 24 VDC or lrom a compatible' Notification Appliance Circuit [NAC). Synchronized via communications** or by the NAC,
if NAC powered
. Manually activated from the control panel
TrueAlarm analog sensing operation:
o Analog sensor information is digitallJ communicated
to the conhol panel via MAPNET II. or IDNetrM,
two-wire conununications-
. Sensor information is processed by the control panel
to determine sensor status
For use with Slmplex@ control panels model
4010, 4020, 410!, 4100U, 4120, and Universal
Transoonders \.\
Functional and architecturally styled enclosure
for ceiling or wall mountlng:
r Sound louvers exit both fiont and side for high output
sound
e Smoke sensor louver design directs air flow to
chamber, enhancing smoke capture
o Built-in magnetic test featurc
Optional accessories:
r Remote alarm LED indicator on single gang plate
o Alarm LED tracking relay
UL listing status:
r Sensor and sounder operation is listed to UL
Standard 268
. Sounder operation is also listed to UL Standard 464
as an audible notification appliance
'R6turlopage4furULClblingstatus.nispDducthasbeenapprwedby0ECalbniaSfrFiE
Marshal (CSFM) Frsuant lo Seclion '13114.1 ol he Califomia Healh and Sahty Cod€. Se€ CSFM
Li;li4$ R00{0m:217 and 7?l{)026:El ltr alo'vable vdues 8rrd/o. co.dbnr ccpeflirg
maledal pGenled i!4 ftb doqmsnt lt b sutiecl b rF€xanimtbn, D!ki4 ard pocsfih
cancalalbn. Accepl6d br use - CiV o{ Nfl Yod( Depatnent ot Buidils - ME Bt93E.
Addilbnal llstrlgE may b€ apphabh, conlrl ]o!.1@l Sirder podrrt $lppf,€r b ho hbsl
sbtu. Lisliqgs and apgwab under Sinplex Ttre Reoder Co. a.s he Flpody 0l TIto Saht
Prcducb Wssbnhsler.
" Total quantity ot soonder bas€s a\slaue br aiding on he sam€ communaalims channd may \4ry
wih parBl appliulion and a,aiablily ol NAC po{er Refer to specilic conh }rnel reqiremenE.
t TrueAlam anahg seascrs atr Foted€d by ono or mfe of t|€ bloNLro U.S. Pabnb: 5,155,4{i8;
5,1n,663; 5,400014; 5,543,77: 5,710,541; 0983,407; D388,352: m92,573. IIAPNET ll a{
lDllet addEssable c{rnmunic"lim designs a|9 gotedod by U.S. Pabflt tlo, 1J96,021
TrueAlarm Pholoeleclric Sensor Mounted in
Sounder Base 4098-9794
Sounder bases combine an audible notification appliance
and a TrueAlarm analog sensor to provide:
Digital Communlcation of Analog Senslng.
Sensors provide an analog measurement that is digitally
communicated to the confol panel where it is analyzed
and an average value is determined and stored. An alarm
or other abnormal condition is determined by comparing
the sensor's present value against its average value.
Intelllgent Data Evaluatlon. Monitoring each sensor's
average value provides a software filtering averaging
process that compensates for environmental factors (dust,
dirt, etc.) and component aging, providing an accurate
reference for evaluating new activity. The result is a
significant reduction in the probability offalse or
nuisance alarms caused by shifts in sensitivity, either up
or down.
Control Panel Selection. Peak activity per sensor is
slored to assist in evaluating specific locations. The alarm
set point for each TrueAlarm sensor is deterrnined at the
control panel, selectable as more or less sensitive as the
individual application requires.
Timed/Multl.Stage Selection. Alann set points can be
prograrnmed for timed automatic sensitivity selection
(such as more s€nsitive at night, less sensitive during
day). Control panel progamming can also provide
multi-stage operation per sensor. For example, a 0.2%
level may cause a warning to prompt investigation while a
2.5%o Ievel may initiate an alarm.
Sensor Alarm and Trouble LED Indication. Each
sensor base's LED pulses to indicate communications
with the panel. If the control panel detennines that a
sensor is in alarm, or that it is dirty or has some other type
of trouble, the details are annunciated at the control panel
and that sensor base's LED will be turned on steadily.
During a system alarm, the control panel will control the
LEDs such that an LED indicating a trouble will return to
pulsing to help identify the alarmed sensors.
s4098-0028-3 9/2003
ffi
Base mounted address selection allows the address
to remain with its programmed location when the sensor
is removed for service or type chenge. Access is from the
front under the removable sensor.
Automatic sensor type identification provides
default sensitivity when substituting sensor types.
Different sensor types can be easily interchanged to meet
specific localion requirements. This feature also allows
intentional sensor substitution during building
construction. When conditions are temporarily dusty,
instead of covering the smoke sensors (causing them to be
disabled), heat sensors may be installed without
reprogramming the control panel.
lntegral red LED indicates power-on by pulsing, or
alarm or trouble when steady on. The exact status is
annunciated at the fire alarm control panel.
Flre alarm control panel operatlon features
include:
o Individual sensitivity selection for each sensor
o Sensitivity monitoring that satisfies NFPA 72@
sensitivity testing requirements
o Peak value logging allowing accurate analysis for
sensitiviqr selection
r Automatic, once per minute individual sensor
calibration check verifies sensor integrity
. Automatic environmentalcompensation
. Display ofsensitivity directly in percent per foot
. Multi-stage alarm operation
o Ability to display and print detailed sensor information
in plain English language
Et'ElE6f,!il
4098-9822, LED Annunciation Relay activates when
base LED is on steady, indicating a local alarm or trouble.
Contacts are DPDT, nted2 A@3DYDC; l/2 A@
120 VAC for transient suppressed loads (requires external
24 VDC coil power).
2098-9808, Remote red LED Alarm Indicator mounts on
a single gang box to provide status indications where the
sensor location mav not be readilv visible.
tilttilrF,fiEEllJ*l
Electrlcal Box Requlrem.nls: (boxes are by others)
Wlthoutlglay: 4' octagonal or 4" square, 1-112" deep: single gang,
2' deeD
lIilhlglal : 4' octagonal or 4' square, 1-'l12' deep, wit\ l1n"
extension ring
4" (102 mm) Octagonal Box
Flush mounl reterance, mount even wilh linal
surface, or wilh up to 1,/4" (6.4 mm) maximum recess
Ootlonal 4098-9822 Rolav
(Mounts in base electrical box
and requires additional
volums, see notes below)
Nolo: Single gang
adapter plals (RACO
No. 787 or equal) is
IgquilelLM€n using 4'
square box (by others)
4098-9832 Adapter Plale, reouir€d for mounting
to g[fa@ mounted box€s (mounts inveied)
L-szi6. (164 mm)-----J-r-
1-1t8'
(29 mml-.s
(Photoelectric s€nsor shown for reference)
NOTES:
1. R€visw actualwire size, wire counl, box type, and whether
4098-9822 relay is used before determining box size.
2. Mounting to flush mounted box also lits single gang handy box,
2-118' (51 mm) doep if wiring allows. (Not applicable if 4098-9822
r€lay is us€d.)
3. For surfac€ mount€d boxss, use 4'squar€ box wilh single gang
adapler plate (RACO No. 787 or equal, by others) or 4' octagonal
box, both require 409&9832 Adapter Plale.
4. Whsn 409&9822 relay is us€d, mount relay in elecldcal box and use
1-ll2'extension ring (by othsrs) on 4' squar€ or octagonal box of'l-112'or 2-118'depth as required.
5. R€ter to Installatlon lnstructions 574-707 for additional infomation.gSlr'rpb
o
2098-9808 Remote LED Alarm lndicator
s4098-0028-3 9/2003
Sealed against rear air flow entry
Electronics are EMI/RFI shielded
Heat sensors:
o Selectable rate compensated, fixed temperature sensing
with or without rate-of-rise operation
. Spacing distance between heat sensors:
Smoke sensors:
o Photoelectric or ionization technology sensing
o 360o smoke entry for optimum response
r Built-in insect screens
TrueAlarm heat sensors are self-restoring and provide rate
compensated, fixed temperature sensing, selectable with
or without rate-of-rise temperature sensing. Due to its
small thermal mass, the sensor accurately and quickly
mea.siures the local temperatue for analysis at the fire
alarm control panel.
Rate-of-rise temperature detection is selectable at the
control panel for either 15' F (8.3' C) or 20" F (l |.1' C)
per minute. Fixed temperature scnsing is independent of
rate-of-rise sensing and programmable to operate at
135" F (57.2" C) or l55o F (68" C). ln a slow developing
fire, the temperature may not increase rapidly enough to
operate the rate-of-rise feature. However, an alarm will be
initiated when the tempcrature reaches its rated fixed
temperature setting.
TrueAlarm heat sensors can be programmed as a utility
device to monitor for temperature exhemes in the range
from 32" F to 155' F (0' C to 68'C). This feature can
provide freeze wamings or alert to HVAC syslem
problems. (Refer to specific panels for availability.)
6.7/16.664 mm)----J
WARNING: ln most fires, hazardous levels of smoke
and toxic gas can build up before a heat detection
device would Initiate an alarm. In cases where Llfe
Safety is a factor, the use of smoke detection is highly
recommended,
ffi
TrueAlarm photoelectric sensors use a stable, pulsed
infrared LED light source and a silicon photodiode
receiver to provid€ consistent and accurate low power
smoke sensing. Seven levels of sensitivity are available
for each individual sensor, ranging from 0.2% to 3.7o/o per
foot of smoke obscuration. Sensitivity is selected and
monitored at the fire alarm control panel.
The sensor head design provides 360' smoke entry for
optimum smoke r€sponse. Due to its photoelectric
operation, air velocity is not normally a factor, except for
impact on area smoke flow.
6-Z1 6' (1 64 mm)---=--+l
4098-9714 Photoelectric Sensor with Sounder Base
ffi
TrueAlarm ionization sensors use a single radioactive
source with an outer sampling ionization chamber and an
inner reference ionization chamber to provide stable
operation under fluctuations in envhonmsntal conditions
such as temperature and humidity. Smoke and invisible
combustion gases can freely penetrate the outer chamber.
With both chambers ionized by a small radioactive source
[Am 241 (Americium)], a very small current flows in the
circuit. The presence ofparticles ofcombustion will cause
a change in the voltage ratio between chambers. This
difference is measured by the electronics in the sensor
base and digitally transmitted back to the control panel for
processing.
Three levels ofsensitivity are available for each sensor:
0.5, 0.9, and 1.3% per foot ofsmoke obscuration.
6'7116- (164 mm)--
-l
4098-9717 lonization Sensor with Sounder Base
EtttEftffiElllfit
Sensor locations should be determined after careful
consideration of the physical layout and contents of the
area to be protected. Refer to NFPA 72,the National Fire
Alarm Code@. On smooth ceilings, smoke sensor spacing
of30 ft (9.1 m) may be used as a guide. For detailed
application information, refer to 4098 Detectors, Sensors,
and Bases Application Manual, Part Number 574-709.
135' F (5i.2'C)
15 fi x 15 ff (4.6 m) fixed
temperalure only;
30nx30fr(9.2m)fxed60 fl (18.3 m)
4098-9733 Heat Sensor with 4098-9794 Sounder Base
s4098-002&3 9/2003
TrueAlarm Sounder Base'
Optlons: 2098-9808 remote LED alarm
Model
4098-9794 (C)
Model
4098-9733 (C)
4098-9717 (C)
Sounder Base
Description
Sounder Base with
connections for Remote LED
Alarm lndicator or
Unsupervised Relay
14 (c)Photoelectric Smoke Sensor
Accessories (ordered separately if required)
Description
Adapter Plate, requir6d for surface mounted 4" electrical boxes
Compatibility
Sensors: 4098-9714. -9717. or -9733
Description
Mounting Requlrsmsnts
Refer to page 2, mounting reference
Mounting Requirements
Refer to page 2, mounting reference
Mounting Requlrements
Refer to page 2, mounting reference
Model
4098-9832
2098.9808 Single gang box, 1-1/2" minimum depth
4098-9822 (C)Mounts in base electrical box (requires 1-1l2'
sxtension on 4'square or octagonal box)
' Rafer lo data sheet S4098-0019 for other compatible bases. Refer to Installation Instructions 574-707 and Application Manual 57/t709 for
additional information. ULC listed model numbers are designated by (C)and require a 'C'suffix such as 4098-9794C.
El!?rm+rftiE
General Operating Specifications
Communicalions and Sensor Supervisory Power MAPNET ll or lDNei, auto-select, 24-40 VDC ddata,400 tA typical,
1 address psr base, supplied by conirol panel
Communicalions and Sounder Power Connections Screw terminals for in/out 18 lo 14 AWG
Remote LED Alarm lndicator Cunenl 1 mA typical supplied trom communications, no impacl to alarm current
LED Connections Color coded wire leads, 18 AWG
uL Listed T 32' F to 100' F (0' C to 38' C)
Operating
Temperature Range
With 4098-9717 or 4098-9733 32" F to 122" F (0" C to 50" C
wirh 4098-9714 15" F to 122" F (-9' C lo 50' C)
Humidity Range 10 to 957o RH
Smoke Sensor
Ambient Ratings
4098-9714. Photoelectric Sensor Air is 0-2000 ff/min m/min)
4098-9717. lonization Sensor Air vslocity is 0-400 fr/min (0-122 m/min); Altilude is up to 8000 fr (2.4 km
Housing Color
Sounder Operatlon
Sounder Voltage
Alarm Cuffent (Sounder On)
Sounder Output
Sounder Power Supervision
(Selectable)
NAC Powered Ooeration
4098-9E22 Unsupervised Relay Option
Externally Supplied Relay Voltage
Frost White
18 to 32 VDC from steady external source or from NAC
20 mA @ 24 VDC, 24 mA maximum @ 32 VDC
88 dBA minimum @ 10 fr (3 m) per UL Standard 464, Aud,Dle Signaling
Applianc$ and UL Standard 268, Smoke Detectors for Fire Ptotective
Signa/ing Systefis
Supervised Seloct for continuous 24 VDC power, loss of power is communicated to panel
Unsupervised Selecl whon connected lo NAC for sounder power, NAC provides supervision
When in alarm, willsound when NAC is in alarm, allowing synchronized
pattern (Tsmporal or March Time, etc.) controlled by the NAC
18-32 VDC, steady source recommended (wires to remote LED l€ads)
Alarm Current 13 mA from 24 VDC supply
Contact Ralings, DPDT contacts for
resistive/suppressed loads
Power limited rating: 2 A @ 30 VDC
Non-power limited rating: 1/2 A @ 120 VAC
Operation Tracks base LED status, relay is on with trouble or alarm at the base
Tyo, Sinpl$, the Simpler logo, TrueAlarm, MAPNET ll, ond lDNet are trodenark of TNo Inrernational Senites tG or its alliliate: in rhe U.S. and/or other countries.
NFPA 72 and Norionul Fire Alarm Code arc rcgistered trodemur*s ofthe Notional Fire Protection Associolion (NFPA).
Tyco Safety Ptoduds tryasfm,nsfar . WestminsteL MA. 01441-0001 . USA
www.ty co s af e ty p r od u c t s- u s a-w m. c o m
s4098-0028-3 9/2003S,Simplex
TrueAlarm Sensors (ordered separately)
Remote red LED Alarm Indicator on single gang
stainless steel olate
Relay, tracks base LED slalus (unsupervised, to be
mounled only in base electrical box)
@ 2m3 TW Salety Pto<ttctt Wesminster All righlt reserwl. All speciftotiors .otd ohet inlongtion thown wr .7tfa1t $ of&rlhenl
S,Simplen
UL, ULC Listed; FM, CSFM
and MEA (NYC) Approved*
Multi-Application Peripherals
Audible Notifi cation Appliances
Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount
Eiltlllfll
Fire alarm speakers with models for ceiling or
wall mount:
r UL listed to Standard 1480
o Four inch cone ( I 02 mm) provides high quality tone and
voice reproduction
o Multi-tapped design provides output power of l/4, l/2,
l, or 2 W with either 25 or 70.7 VRMS input
r In/out wiring terminals for 18 AWG to t 2 AWC
. Mounts to 4" squar€ outlet box, l-l/2" deep with l-ll2"
deep box extension
r Capacitor input for connection to supervised notification
appliance circuits
. Rugged, high impact, flame retardant thermoplastic
housings
Rectangular housing models feature:
. Appearance that complements TrueAlerto strobes and
speaker/strobes
o Red or white housings with "FIRE' lettering for surface
or semi-flush wall mount
. Optional matching adapter skirts for covering surface
mounted electrical boxes
. Optional red wire guard
Round housing models feature:
. Off-white color (no lettering) for flush mount on ceiling
or wall
Simplex@ 4902 Series speakers provide high quality sound
for emergency fire alarm use as well as for background
music. The moisture-repellent speaker is designed for
smooth frequency response with minimal distortion.
The multi-tapped speaker transformer accommodates
either 25 or 70.7 VRMS and provides an output of from
1/4 to 2 W to provide flexibility for satisfring the
requirements of the installed conditions.
Rectangular housing models are for surface or semi-flush
wall mount applications. Round housing models are
typically for ceiling applications but can be wall mounted
ifdesired. The rectangular housing speakers are designed
to compliment the TrueAlert family of strobes and
speaker/strobes, providing conventional, non-addressable
speaker operation.
' Reler to page 2 fo{ guard listhg. Tlis poduct has been app@ved by fi€ Califonh Slale
Fire Ma6hal {CSFM) purslanl lo Sectioo 13114.1 ol ho Calihmia Hodh and Safely Codo.
Ss€ CSFM Usling 732Hm26:242 lor altow?ble values and/or conditims conc€ming
maleaial presenled In his docunenl. lt is subiect lo re€xaminalion, rovision, and poslible
canc€llation. Addibnal lislings may b6 appkable; co0lacl your localSinpl€x produci
slpplbr fo. he labsl sl8tus. [islius and applovsls unds Simpler nrc Recordor Co. are
the prop€rly ot lyro Salety Prcduds Weshinsl€r.
Rectangular Wall Mount Speakers are Available
as Red with White "Fire" Lettering and
White with Red 'Fire' Lettering
Round Speakers are Available in Off-White (no lettering)
E@@6
Housing Dimensions
Depth into Box
Dlmensions, Round Housings
Housing Dimensions
2-314' (70 mm)
7-112' Diameter, 1/2" 0
Depth into Box
General Specificatlons
. Compatible with optional tile bridge 2905-9946
@ffid
ffiVI
Dimensions, Reclangular Wall Mount Housings
5-1/8'Hx5"Wx1-1/2'D
(130 mm x 127 mm x 38 mm)
(191 mm x 13 mm)
2-314" (70 mm)
25 or 70.7 VRMS
.82 mm2 to 3.31 mmz
125lo 12kHz
32' to 100' F (0' to 38"
10% lo 95% RH from 32' to
122' F (0' to 50"
s4902-0003-5 8/2005
tit?JmEEGtt*rf,lltl
4902-9717(CA)
4902-9721 (CA)
' ULC listed model are designated with a CA suffix.
Mounting Adapters
Descrlplion
Red speaker cover wlth white 'FlRE" lettering
4905-9989
4905-9999
Speakers
Model'
4902-9716(CA)
Model
4905-9988
Doscription
Rectangular housing, wall mounl
speaKer
Red wilh white "FlRE" lettsring
Interchangeable with
TrueAlert horns
Dimensions
5-118"Hx5"Wx1-1/2'D
(130 mm x 127 mm x 38 mm)
7 -1 12' Diameter x I 12" D
(191 mm x 13 mm)
Dlmensions
5-1/8"Hx5'Wx1-1/2'D
(130 mm x 127 mm x 38 mm)
6-1/16' H x 6-1/16" Wx 3-1/8' D
( l54 mm x 154 mm x 79 mm)
White ,niih red "FIRE" lettering
Model
4905-9941 Red
Description
I Use to cover surface mounted| 1-112' deep box wilh l-1l2"Surface mount adaDtar skirl II deep extension external to
I wall (see diagram on page 3)
Dimenslong
5-3/8' H x 5-114" W x 3-3/16' D
(136 mm x 133 mm x 81 mm)
Total surface deoth with
speaker = 4-518" (117 mm)4905-9942 White
2905-9946 Tila bridge for 4902-9721 Speaker See diagram on page 3
4905-9931 Adapter Plate, red, for mounting to 2975-9145 box (typically for retroflt,
may be mounted vertical or horizontal)
8-5/ 16' x 5-3i4" x 0.060' Thick
(211 mm x 146 mm x 1.5 mm)
297 5-9145 Red mounting box, requires Adapter Plate 4905-9931 7-718' x *118" x 2-314' D
(200 mm x 130 mm x 70 mm)
Covers and Guard
Whits speaker cover with red "FIRE' lettering
Red wire guard with mounting plate; compatible wilh semi-flush or surface
mounted boxes: for use with 4" square elecuical box mounting hole
patterns only (UL listed by Space Age Electronics Inc.)
Mounting requires a 4" (102 mm) square
box, 'll/2" (38 mm) deep, with a 4" box
extension, 1-112" deep, by others
Speaker assembly
Wiring input terminals and sp€aker lap
selection are accessible ftom rear of
speaker housing
Transparent speaker
houslng
Romovable cover
(tool required)
,
t
t
rJ
,
t
s4902-0003-5 8/2005
4" square, 1-112' deep box
with 'l-'1/2" €xtension (by others)
Wiring input terminals and speaker
taD selection are accessible
rear of speaker housing
ffi
1t2'
(13 mm)
2311/16'(602 fln)
4" (102 mm) square box, 1-1/2" (38 mm) deep
with conduit shown for reference
4' (102 mm) square box
extension, l-1i2' (38 mm) deep
ODtional 4905-9999 Wire Guard
Surface mount adapl€r skirt, 3-3/16" deep:
4905-9941, Red: 490s9942, whito
3-3i/4' (95 mm) squaro 0.024' thick sheet
metal, iolded with
1/2 llp each sid€cutout. cent€red on plat6\
| /-a--'.1
\*"or"..r",rod L--rl
611/'t6'
('170 mm)
s4902400$5 8/2005
,
Sound Output Ratings @ 10 ft (3 m) per UL 1480 Reverberant Chamber Testlng
Model
4902-9716
4902-9717
Type
Rectangular Housing
Input Voltage
25 VRMS
Selected T
1l4W
80 dBA
1t2W
83 dBA
1W
85 dBA
2W
88 dBA
70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA
4go2-9721 Round Housing either 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA
Sound Output Ratings @ l0 ft (3 m) pe. ULC 5-541 Testlng and per Anechoic Chamber Testing
Model
4902-97 16 , 4902-97 't7 , & 4902-9721 i
with either 25 VRMS or 70.7 VRMS
Test
Output Tesl per ULC 5-541
Sslected T
1t4W
78 dBA
1t2W
8I dBA
1W
84 dBA
2W
87 dBA
Anechoic Chamber, 1 kHz input, on-axis'87 dBA 90 dBA 93 dBA 96 dBA
. Anechoic speaker output ratings are typically more representative of actual installed sound oulput.
85
;84
o
882
'o 81
o--
oJo79
a--
oLtt
5,.o
-2kHz -
4kJlz
s0 80 70 60 50 40 30 20 10 01020 30 40 50 60 70 80 90
Angular Displacement (Degroes) on Horizontal Axls
4905-9931 Adapter Plate
4905-9999 Optional
Wire Guard
(shown hero for
reference only, can
be used on other
mounting options)
Speaker assembly
Tyro, Sinple\, lhe Sinplet lo8o, ond Truellerl, are lro.leno s ofTlL'o lnternalio al Senices AG or its onilialer in the U.S. and/or olher co ntries.
FIRE
490S9931 Adaoter Plate
S.Simplex Tyco Satety Producls Westminster Westminster, MA. 01441-0001 . USA
ww w. ty co s af e ty p rod u ct s- u sa -w m. co m
s4902-0003-5 8/2005
@ 2005 Tlro Wty hofcts Wpttmins@. All rEhts tsoa'ed. All slreilitdio$ od oher inlon nrion show tEre dnott .\t ofd61lnent revision .lote
TowN op verl
75 S. FRONTAGEROAD
VAIL, CO 81657
970479-2138
Job Address:
l,ocation.....:
Parcel No...:
Project No :
ELECTRICAL PERMIT
174 GORE CREEK DR VAIL
THE LODGE APT CONDOS #530
2t010822t074
??lo1 - 6ooQ
s57. s0
$0. 00
$0.00
Permit #:
Status. .
Applied.
Issued .
Expires .
03 /20/2007
03/20/2007 Phoner 376-L846
03/20/2007 Phone: 376-L846
Total Calcularcd Fees- >
Additional Fees----- >
Total Pernit Fee---- >
w7-m28
Go1 -Oo(.S-
: ISSUED: O3l20l2OO7: 04lO2l2N7.: 09/2912007
DEPARTMENT OF COMMUNITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
OI'INER TYTEI,, HOWARD & SANDRJA
1OO OYSTER BAY RD
MILI,NECKlw LL75s
APPI,ICAIiN PTARMIGA}T ELECTRIC INE.
License:373-E
CONTRACTOR PTARMIGAI.I ELECTRIC INC.
I-,icense: 373-E
Desciption: AADDINGNEW LIGHTING AND ELECTRICAL FOR NEW MASTERBATHValuation: $0.00 Square feet: llm
'tt'l,i**{.,t:llrt:lrt:|.*t:t
Electrical-*--- >
DRB Fee*---- >
Investigation-- >
03/26/2oo7 SHAHN
Item: 05500 I'IRE DEPARTMENT
$60.50
s0.00
$50. s0
Will Call-----> $3.00 Payments----------- > $60.50
TOTAI FEES- > $50.50 BALANCE DI'E------ > S0. o0
Approvals:rtem: 05000 ELECTRICAIJ DEPARTMEMfAction: AP
CONDITIONS OF APPROVAL
Cond: 12(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAI{CE.
Cond: CON0008799
MAINTAIN FIRE RATING OF 1 HOI'R
Cond: CON0008800
REPI'ACE EXPOSED TYPE NM CABLE
Cond: CON0008801
ARC FAI[-,T PROTECTION REQUIRED FOR BEDROOMS IF WAIJI-,S ARE OPENED DITRING PRO.]ECT.
DECLARATIONS
I hereby acknowledge ttrat I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and suMivision codes, design
review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto.
REQTJESTS FOR INSPECTION SHALL BE MADE TWENTY-FOI,JR HOTJRS IN OFFICE FROM 8:00 AM - 4
FIJOOR/CEIIJING ASSEMBLIES .
WITH APPROVED CABLE/COI{DUIT.
PM.
VANCE BY TELEPHONE AT 479.2149 OR AT
AND OWNEtr
APPLICATIOI{ WILI IIOT BE AGCEPTED IF I1{CO}IPI-ETE OR UIISI
Prcjtxt #:- ooo
75 S. X'rontage Rd.
Vail, Gololado 81657
6s]. oe)Zg Building Perm
Electrical Permit #:
97 O-47 9-2149 (Inspections)
TOWN OF VAII ELECTRICAL PER}IIT APPUCATION
COT{TRACTOR IIIFORIIATIOI{
Electrica I C.ontractor:
?not?rAt/n o,\ F, F.r'r? |c
Town of Vail Reg. No.:373- e Contact Person and Phone #3:Kvzr 3?a - tBya
E-ilail Addr€ss: ,3 Fax#:
Crntractor Signafure:(n A--
COMPTETE SQ. Fd)TAGE FOR AREA OF WORK Al{D VAIUATIOI{ OF WORK (rabor & lrlatedals)
AMOUNT OF SQ FT IN STRUCTURE:ELECTRICALVALUATION: $ /O DOO
Offieetg #Par ,# Z, Ot O,C3Z? t O? 4
JobName: Lorrte ,+, l/er- H sg JobAddress: r?/ cxrzn Cunu, pz
tegal lt€cription I LoE I Blodr: I riting:Snbdlvlsion:
owners Name: 7" Teq I Address: tfr| 3!::1P^y,lt:.- | Pt'one:
Englneer:Address:Phone:
Debifed description of work: COurro f?eno ec,-_ . F'i".-t^ "rc,-l , .,rs-, etL B,a.rr{ .
A o r> ,n,rt N e,--t z- r G Fr i r;) L->
WorkOass: New() {!g!ju"(l rqrd"l(2Q Repair( ) Temppower( ) Other( )
Work Type: Interior ()0 Exterior ( ) Bo$ ( )Does an EHU exist at this location: Yes ( ) No ( )
Typeof BHg.: single-famiv( ) Drpbx( ) MuftFfamity0o oornrnercftil ( ) Restaurant( ) odrer( )
No. of Existing Dwelling Units ln this building:No. of Accommodation Unhs in this buildtng:
Is this permit for a hot tub: Yes ( ) No ( )0
Does a Fire Alarm Exist: Yes (V No ( )Does a Fire Sprinkler g6tem Exisil Yes ( X No ( )
********!r********FOR OFFICE USE ONt eceeIv/E* ********* * ********
F:\cd6AFORIlrS\Fermits\Eif&U\ffiJermtt-1r-232$5.DOC / r-, **rn,9u tu23,nm6
TOWN OF VAIL FIRE DEPARTMENT
75 S. FRONTAGEROAD
VAIL, CO 81657
97M79-2135
VAIL FIRE DEPARTMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT
Job Address: 174 CORE CREEK DR VAIL
Location.....: THE LODGE APT CONDOS #530
Parcel No...: 210108221074
ProjectNo : -?T(f 01-600Q
OT{NER TYTEI.,, HOWARD & SANDRJA
1OO OYSTER BAY RD
MIIJI,IiIECK
NY T1765
APPI-,rCANI ALL STATE FrRE PROTECTTON, LO4/25/2007 Phone: 303-288-3901
504s E 76TH #L2
COMMERCE CITYco 80022
L,icense:370-S
coMtRAcToR Ar,r-, STATE FIRE PROTECTTON, r04/25/2007 Phone: 303-288-3901
604s E 76TH #L2
COMMERCE CITYco aoo22
L,icense: 370-S
Desciption: ADD/RELOCATE SPRINKLER HEADS
Valuation: $1.000.00
FEE SUMMARY
F07-0023
ISSUED
04/25t2007
05/ut2007
04/2s/20o7
Mcchanical-->
Plan Check--- >
lnvesigation->
Will Call--->
$o - oo Resruarant Plan Review->
$350 - 00 DRB Fee-----
$o . oo TOTAL FELS-->
s0-00
so. oo Total Calculated Fees-->
$0.00 Additional Fees---.----- >
$392.50 Total Permit Fe!----->
Payments------.------- >
BALANCE DUE-:__->
$392.50
50. 0o
$392.50
s392. s0
s0. 00
Item: 05100 BUII-,DING DEPARTMEI{:rItem: 05600 FIRE DEPARTMEICI
os/o2/2oo7 JJP* Action: AP
CONDITION OF APPROVAL
Cond: L2
(BI-,DG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAI{CE.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivisioo codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SIIALL BE MADE TWENTY-T'OUR HOT]RS IN ADVAI{CE BY TELEPHONE AT 479-2135
FROM 8:00 AM - 5 PM.
SIGNATURE OF OR CONTRACTOR FOR HIMSELF AND OWNET
??f 61-ooo 6
owNER TyrEL, HowARD & SAIIDRA o3/Ls/20o7
1OO OYSTER BAY RD
MILLNECK
NY 17-765
APPTICANT CONCEPT MECHANICAI,
PO BOX 1155
AVON
coLoRADO 8L620
License:314-M
coNrRAcroR coNcEPT MECrrANrCArr 03/t5/2O07 phone: (970) 949-0200
PO BOX 1155
AVON
COIJORADO 8l-520
I-,icense : 314 -M
Desciption: ROUGH IN AND SET TWO FLOOR VECTORS AND ON PIECE OF
BASEBOARD. ROUGH IN AND SET TWO WALL MOUNTED A.C. UNITS
Valuation: $12.500.00
Fireplac€ Information: Restsicted:# of Gas Applianc€s: 0 # of Gas Logs: 0 # of Wood Peller 0
't***rat :t*:*)*+a+t**'t'i.t,|**:t+,tt**'ll.'|:t***'t++:t **'tt t**:i:*aa+*t:i'lr,lr,t**'i:t+'ia't*rii FEE SUMMARY
Mechanicsl-- > 5250.00 Resoarant Plan Rcview- >S0. 00 Total Calculaed Fee.s-> $328 . 00
Plan Check--> S65.00 TOTAL FEES-----> S328.00 Additional Fees------ >
TOWN OF VAIL DEPARTMENT OF COMMT'NITY DEVELOPMENT
75 S.FRONTAGEROAD
vArL, co 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT Permit #: M07-0031
Job Address: 174 GORE CREEK DR VAIL
Location.....: THE LODGE APT CONDOS #530ParcelNo...: 210108221074
361- 6o t5-
Status...: ISSLIED
Applied. . : 03115/2W7
Issued. . : Mll0/2W7
Expires . .: l0lU7l2ffi7Lrgal Description:
Project No :
03/t5/2OO7 Phone: (97o) 949-0200
InvestigatioD- >
Will CaIl--->$0.00
$3.00
s0. 00
Total Permit Fee-----> $328.00Paym€nts-------- > g328. oo
+f+it*+**+|*+|+||t,t*'**||*ti||'t***t*|t+t.|+'l|'it'lt!*|||+|+||ti!*.|ttt+:t:fj}'+'||l't:|!.*:i:ttf+|+*'*
Item: 05100 BUIIJDING DEPARTT'{ENT
o4/09/2oo7 JRII Action: AP
Item: 05500 FIRE DEPARTMEMT
CONDITION OF APPROVAL
Cond: 12(BLDG.): PIETD INSPECTIONS ARE REQUIRED TO CIIECK FOR CODE COMPIJIAIICE.
Cond: 22
(BLDG. ) : COHBUSTION AIR IS REQUIRED PER CHAPTER 7 OF TIIE 2003 IMC AlilD SECTION
304 OF THE 2OO3 IFGC AS MODIFIED BY TOWN OF VAIIJ.
Cond: 23(BLDG.): BOIILER INSTAITLATION MUST CONFORI'{ TO MANUFACTURER'S INSTRUCTIONS A}ID
CHAPTER 10 OF TITE 2OO3 TMC.
Cond: 25
(BI-,DG.): GAS APPIJINiICES SIIALL BE VEIITED ACCORDfNG TO CHAPTER 5 OF TIIE 2003 IFGC.
Cond: 29
(BLDG. ) : ACCESS TO MECHANICAL EQUIPMENI MUST COMPITY WrTII CHAPTER 3 OF TIIE 2003
IME AND CIIAPTER 3 OF TITE 2OO3 IFGC..
Cond: 31
(BLDG. ) : BOILERS SHAIL BE MOIINTED ON FLOORS OF NONCOUBUSTIBLE CONST. UITITESS
IJISTED FOR MOIINTING OII COMBUSTfBLE FIJOORIIIG.
Cond: 32(BLDG.): PERMIT,PI-,ANS AND CODE AIIA].rYSTS MUST BE POSTED IN MECIIANICAIJ ROOM PRrOR
TO AN INSPECTION RSQI'EST.
Cond: 30
(BLDG. ) : BOILER ROOMS SIIAIJI-, BE EQUIPPPED WIfg A FIJOOR DRArN OR OTIIER APPROVED
MEANS FOR DISPOSING OF I,IQUID WASTE PER SECTION 1004.6.
DECLARATIONS
I hereby acknowledge that I have read this application, frlled out in full the information required, completed an accurate plot
plan, and state ttnt all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this sfructure according to the lowns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordhances of the Town applicable thereto.
REQT ESTS FOR INSPECTION SIIALL BE MADE TWENTY-FOIJR HOIJRS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OIJR OFFICE FROM 8:00 AM - 4
PM.
TURE OF OWNER OR CTOR FOR HIMSELF AND OWNEF
APPLICATIOI{ WIIL ilOT BE ACCEPTED IF I]{COilPT"ETE OR,(P.o\o 6
75 S. Frontage Rd.
Vail, Golorado 81657
TOV Project #:
Building Permit
Mechanical Permit #:
97 V 47 9-2149 (Inspecdons)
*:t**{.**:r.*K*r,F*
*"
l\07--oos I
Provlde l{edranical Room lryoutdrawn to scaleb Indude:n l.ledranical Room Dimen3ions Al/h , ,o Cornbustion Afr Drrt 9ze amll-wtion l{[*o Ffue, Vent and Gas Llnc Slze and trrcail,{n Nlt
ll€at Loee C.lcs,
Equlpmcnt Cut/Spoc Sh€ets
:r * * * * + 8,r FoR oFFICE USE OI{LY* * t * * * l.'r :r * * * *'r * * * * * * * * * * * :r * * *
OdprFs:D.bn drd:
leafird Dy:
s-
I
Permft will not be acoepted without the following:
CONTRACTOR INFORMATION
Medpnical C.onbactor:
Conccpl f\<-cL....-^1, ,u) 7'tt
Town ofVail Req. No.: .t& 6rr{_/Vl
Contact Person and Phone #'s:
T^ /o s.n ?/? -o ta o
E-ilaff Addi€ss.bzt-czl' ,rnd a,...,'zJ€ Fax#: E//E.-O ?.ia
cont"ctor slsna*,.' fr;;hq6/ ; v. p / ;;:frU* "
MECMNICAL: $/45@":
Job Mdress: U4; tJobName: +-+-t / r
Oie Jzice-e- o 'ou4h inseboan sef ,.t'tantt4l,1 l 11 Q €e+
'aa-{ars Qr(dlato tu ol l- ua tt (+/ a. e.
workClass: Ner'r() Addltion( ) Alteration(y') Repair( ) Other( )
Boller LocaHon: Interlor ( ) Exterior ( ) Other (Does an EHU o{st at this location: Yes ( ) No (-il
Type of BHg: Single-famlly ( ) niphx ( ) Mufti-family ( r).4estaurant ( ) O$er ( )
No. of Existing Dwelling Units in thls buildlng:No. of Amrnmodation Units in this building:
of
Nofiypeof FlreplaesProposed:@sApdlane( ) Gastoss( ) Wood/Pellet( ) WdBuming(NOTAI.IOWED)
Is this a @nversion from a to an EPA Phase II device? Yes ( ) No
F:\delr\FoR}'ls\Fenn'ts\EulldirEvnedEnkaurendlf f -23-2m5. DOC rv3,nm5
rl
TOWN OF VAIL
75 S.FRONTAGEROAD
VAIL. CO 81657
970479-2138
Job Address:
L,ocation.. ... :
Parcel No...:
Legal Description:
Project No :
PLUMBING PERMIT
174 GORE CREEK DR VAIL
THE LODGE APT CONDOS #530
210108221074
?ql or <f oG
Status . ,
Applied.
Issued .
Expires .
03/L5/2Oo7
03/L5/2007 Phone: 970-949-o2oo
03/L5/2007 Phone: 970-949-02OO
# of Gas Logs: 2'l
So. o0 Toal Calculated Fees-- >
$255.50 AdditionelFees---->
ToAl Pemft Fee--*- >PaYnrnts--------- I
BALANCE DUE.---.---- >
DEPARTMENT OF COMMI.]NITY DEVELOPMENT
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
Permit #: P0f-Wzl
OWNER TYTEI,, HOWARD & SA}IDRA
1OO OYSTER BAY RD
MII.,L}IECKNY LL765
APPLICANI CONCEPT MECHAIIICAIJ, INC
P.O. BOX 1155
AVON
co 81520
License: 189-P
EONTR,ACTOR CONCEPT MECHANICAIJ, TNC
P.O. BOX 1165
AVONco 81-620IJicense: 189-P
Jo r -60(t
ISSUED
03/t5tzw
Mtrct2w
rutu/2007
# of Wood Pallet: ??
$26s. so'$0.00
$265.50
$25s.50
$0.00
Descipion: ROUGH IN DWV AND WATER TO NEW FIXTURE LOY OUT. SET AND TRIM
FIXTI.JRES
Valuation: $13.500.00
Fireplac€ Information: Restricted: ?2 # ofGas Appliances: ??
+!lttt***++t+'rtr.:t!t**tt:i{.,r*'rd(***?+{.i!*l**'t**i+**'r'ltd.*t*:r:r+,r***'}**'r:f :r+r*** FEE SUMMARY
Plumbing--- >
Plan Check-- >
Invesdgation- >
Will Cdl-- >
5210. 00 Restuarant Plan Review- >
$s2. so TOTALFEES- >
$0. 00
s3.00
Item: 05100 BUILDING DEPARTIIEIII
o4/09/2oo7 JRr4 Action: AP
Item: 05500 FIRE DEPARI'l,tEllT
CONDITION OF APPROVAL
Cond: 12
(BI-,DG.): FIEL,D INSPECTIONS ARE REQUIRED TO CIIECK FOR CODE COMPLIAIICE.
'|****l||**'|+i+ttt|t****ii+|*|t***'|.i|+||'|t***'|||+|ttti||ia|||t**
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in firll the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances ard stat€ laws, ard to build this structure according to the towns zoning and suHivision codes, design
review approved, International Buildhg and Residential Codes and other ordirunces ofthe Town applicable thereto.
TOWNOFVAIL, COLORADO
Statement Nuniber:
Palment Method:
Mechanical / ck LO6o2
R070000445 Amount !
check
Statement
$25s.s0 04/ro/20071-1 :28 AMInit: LTlilotation: Concept
Permit. No:Parcel No:Site Address:Location:
This Payment:
ACCOT]NT ITEM IIST:
Account Code
P07- 0021 TI4)E: PLT,MBING PERMIT
+++*******+*****'t**i++l'******++*+'i******+*+t****t*++*'f*****++*******t++**************++*****
2IOL-O82-2107 -4
174 GORE CREEK DR VAIL
THE LODGE APT CONDOS #530
s26s . s0
Description
Tota1 Fees:Total ALL Pnts:
Balance:
$265 .50
$255.50
90.00
Current Pmts
PF 00100003112300
PP 00100003111100
wc 00100003112800
PIJAN CIIECK FEES
PIJ]MBING PERMIT FEES
WIIJIJ CA].'L INSPEMION FEE
52.50
210. O0
3 .00
APPLICATIOI{ WIII.]IOT BE AOCEPTED IF IIICOHPI"ETE OR
ProJect #:o7qooA
Building
Plumbing Permit #:
9ro-479-2l.49
TOWN OF VAIL PLUMBING PERTTIIT APPTICATION
?b7. sqle/r-f_z-l
75 S. Frontags R||.
Yail, Colondo 81657
Torrn of Vall Reg. No.:
) v.P. /s
COIIPLETE VAIUATIOIT FOR PtUttlBIl{G PERIIIT (labor & t{aterials)
PLUMBTNG: t 19,500"-'
Otuat9
Paref * R./O/ OK Z -21074
robName: 7y fa/ R* s i/*, e<-
l.€gEl Decqiption I Loft | Blodr: I Filing:SubdMdon:
W-ylwi .. 4^i^ rt /.- tl'ffiry'?,"- 9rr?uP,,r frJool*n'
Pa at I 2-Phone:q 4 o o
work:eulht?i'rn in Dlura.Cvfztrts,ktek, zb ne*t 6'xt7tre.aqpa*,eta ' ) Herud./Work0ass: Neur() Mdltion( ) Alteraton(y') Repatr( ) Odter(
TypedBfdg.: Singfefamlly( ) Dupfer( ) Muld;tardlV?t{Conrmercial glf n*unrf'( ) Oilrer( )
N,o. of Edsting Dwellirg Units in this buildlng:7 l'lo. of Accommodation Units In this bultding: 7
rl*!:.*******r***f*r**************rtr****FOR OFFIGE USE OtlLY.*****tl****rt****tt*******t*********
F:WaAFORIIS\PERI{[S\edHing\drnit tg.JsflrLl 1-23-2@5.da PagE I of 1 flf,3nm/s
^ .l
Sub Tvoe: AMFU'se: lll A Status: ISSUEDInsp Area: JRM
Phone: 970-949'1800AND RISERS, PLUMBING FIXTURES, ELECTRICAL FIXTURES,
Requested Time: 08:30 AM' Phone: 90.1-1283
Entered By: DGOLDEN K
. NOTIFICATION
Action: AP APPROVED
lz*-lt3ooz lnspec$LT Fe,{tu??t n8Porting eage 0t
Requested lnsp€ct Date: llonday, Decombor 17,2007' Insoection Area: JRll
Site Address: I74 GORE GREEK DR VAIL
THE LODGE APT CONDOS #530
WA,
14^
Item: 226Item: 30Item: 50Item: 60
Item: 70Item: 90
Roouosted Inspection(s)
Item: 90 BLDG.FinalRequestor: BECK BUILDING COMPANYConiments: will call 904-1283Assioned To: SHAHN" Action: Time Exo:
Insoection Historv
** Approved *
: SHAHN.
: 807-0269
REPT131 Run Id: 7396
lz*-ltSooz lnspec$$l
FedlyF?t
neeorting eage oz
Requested Inspect Date: ilonday, Dscembor 17, 2007' Inspectlon Area: JRM
Slte Address: 174 GORE CREEK DR VAIL
THE LODGE APT CONDOS #530
A/P/D Information
Activitv: M07-0031
Const Tvp6:Ofier: TYTEL. HContractor: CONCEPT IDescription: fi?tsn#ifi
Reouested lnsoectaon(s)
Inspection Historv
Item: 200
Item:310Item: 315Item: 320Item: 330Item: 340Item: 390
,lfiAonroved
*
Action: AP APPROVED
Type: B-MECH Sub Type: AMF Status: IS-SUEDcqp_ahby: U'se: Insp Area: JRMIDRA -
,L Phone: (970) 949-0200
I/O FLOOR VECTORS AND ON PIECE OF BASEBOARD. ROUGH IN AND SET
A.C. UNITS
Requestod Tlme: 09:30 AItl' Phone: (970) 949-0200
Entered By: DGOLDEN K
REPT131
t.
Run Id: 7396
.. ,
A/P/D lnformatlon
Conkactor:Description:
Inspoctlon Historv
Item: 220
Item: 230
Item:Item:
Activitv: P07-0021Const Tvo6:O\,ltien TYTEL. H
Requested Inspect Date:' Inspec{ion Area:Site Address:
ID.W.V. * Aoproved **
Inspector: JRM
ilonday, Decombert 7, 2007JRM
174 GORE CREEK DR VAIL
THE LODGE APT CONDOS #530
TO NEW FIXTURE LOY OUT. SET AND TRIM FIXTURES
Status: ISSUED
Insp Area: JRM
Requestod Tlme: 03:00 PM' Phone: 970-949-0200 -or- 331-4508
Entered By: DGOLOEN K
SubTgOe: AMF
Phone: 970-949-0200
Action: AP APPROVED
Action: APAPPROVED
240260
290
Water * Aooroved "Insoector: JRMSTREET PRESSURE
lffnroveO *
Insoector: JRVENTING APPVENTING APPROVED* APProved *
lnsoector: JRM'Insoector: JRM' Action:
1 SATH AND KITCHEN COMPLETE
APAPPROVED
PA PARTIAL APPROVAL
- Action: Time Exp:Comment: -T-FATFANLFKITCHEN COMPLETE
REPTl31 Run Id: 7396
OOTITi|TYEIELOFIE}{I
Design Review Board
ACTION FORII
Department of Community Development
75 South Frontage Road, Vail, Colorado 81657
tel: 970.479.2139 tax. 970.479,2452
web: www.vailgov.com
PrcJeCt Name: TYTEL RES, ADDMON
Project Descrlption:
Participants:
1052 MESA DRIVE
P.O. BOX 1138
EAGLE
co 81631
License: 882-8
Prcject Address: 174 GORE CREEK DR VAIL
Legal Description: lot: A Block Subdivision:
Partel Number= 2LO1-082-2L074
Comments: See@ndiitons
DRB ]{umber: DR8070005
Request for an interior conversion of 110 square feet. Includes the addition of one new window
and a window to be replaced by a french door.
owNER TYTEI-, HOWARD & SANDM 0Ll08l2OO7
1OO OYSTER BAY RD
MILTNECK
NY 11755
APPLICANT WALKER BUILDING COMPANY 0L10812007 Phone: 970-328-9362
1052 MESA DRIVE
P.O. BOX 1138
EAGLE
co 81631
License: 882-8
CONTMCTOR WALKER BUII-DING COMPANY OUA8,|?:OOT Phone: 970-328-9362
LocaUon: THE LODGE APTCONDOS #530
LODGE APT CONDO (TlrE)
Mouon By:
Second By:
Vote:
Gonditions:
BOARD/STAFF ACTION
AcIiOn: STAFFAPR
Date of Apprcva l= OLI LOl2007
Cond:8
(PLAN): No changes to these plans may be made without the written @nsent of Town of
Vail staff and/or the appropriate review committee(s).
Cond:0
(PLAN): DRB approval does not constitute a permit for building. Please consult with
Town of Vail Building personnel prior to @nstruction activities.
C.ond:201
' DRB approual shall not beome ralid for 20 days follodng the date of approval.
Cond: 202
Approral of this project shall hpse and become void one (1) yer following the date
of final approval, unless a building permit is issued and onstructlon is commenced
and is diligendy pursued to,vard completion.
@ndr 113
All developrnent applicaUons submitted to the Town after the effective date of
Ordinance 26, Series 2006 shall be subject to the pending employee housing
regulaUons in whatarer form they are finally adopt€d; prodded, however, that if
the Town fails to adopt the pending employee housing regulaBons by April 15, 2W7,
this Ordinance shall not apply to such dwelopment applications.
Cond: CON0@8619
The applicant shall reconstruct the aderior of the building in a manner which does
make it evident where wlndows were removed or added. This may entail replacing more
siding than just patching locations where windows were removed. Under no
circumstanae should it be distinguishable were old and new materials meet.
Cond: CON0008620
The applicant shall match all windows, doors, siding, and @lors to those existing
cunendy on the s&ucture.
Planner: Wanen Campbell DRB Fee Pald: t3qr.O0
allilsl26E7 2lt6r -5169222748
Jen 04 07 04:,l5p GilY D. WrI€r
I |{ta-p2
970 32B 7016
*ffi AdfiEons-nedqqtel or Gornmqdal*iffiil"n for Dc.lgn n:vlar
.ffi*?u|fi!ffis-
S:rtr'*P'4dn
i.i"frr'i'c';ietd,.|E*1figffiffiffi38ffi.?.Hfff,il1";;a*' "'--;i5;m * T- t f t,
LorzdonoftletFed t b-4och-SuHfYbHri' ---'.-'--
*a r-t @(ffi Egile co' rrs'dr !t go-3zs{glo b oarcd no')
tJ
nl
wo
{ooo(lttr
trr
tr
tirrtptur Ctlrc RtrilrG
Zoolng:
il6rm(t)ofm(i}
lnllhgllrc
o'nrtalCgl|il|fqt}
r|arnedlplhanG
lhifingAdcps
E-nrflAddrcrr:
itlDG af R.lrid
tl Si$E
Co.GFdferhr
I|ew@Fu&rAtffil
I'tnF Alhirtlon(ilrt{amffytcctrrrtdD
tttrAltsrrtigt(dry:firffidc)
o grrlErrte Atrordl PlilE
tt SrF doo RnuGt
lasfl0ll
f2$
. frct
lso gtlltlfi|F?$Erlffidu4nJt''
Itlo Fe!
For Gorguctlqt d t tFl hfltE a &nE ilhld.
Fir; ddfid| ut-t {tl''l lboalll is &b tr*lcrfia[
qm#l hrfino Fuunl 2!0 dtii''s I qFrnnnordrmgerEhng[d+irgldtg, p* tgr ffi l|ffils, F@FE|frncr fli.l tttatnh9
r*r.B
|QO iailotarcgcrbhffrgsed JtcinFo'stlcnl$ ldl'r
;Jd!;Fftto; *iodi auu h&capl'R' ffi nd nirrthe
rds, tle3!0 hr ilf*t5 to pb.E ll|r ltt .Deil,€d bt tlatrft|g stF a $t Dtshn
Rt||!3dt|.
ltbFF
/rtf
{30
/odS. /7 Uu/
January 4,2007
Mrs. Sandra Tytel
174 E. Gore Creek Drive
Vail CO 81658
Dear Mrs. Tytel:
The Board of Managers for Lodge Apartment Condominium Association has received
your request to remodel your condominium. The construction will include the following
projects:
1. Remodel the entire kitchen.
2. Remove all flooring and replace.
3. Remove all batbroom fixtures and replace.
4. Moving walls to facilitate bathroom remodels.
5. Additional I l0 square feet offloor space.
6. Ele.ctricalupgrades.
7. Replacement of all windows to match existing.
8. Addition of a window and reconfiguration of the balcony door.
Subject to the following conditions the Board of Managers hereby approves of the
proposed plans:
l. An approved condominium construction document is signed and all conditions are
adhered to.
2. All required permits are obtained from the Town of Vail.
We wish you well in your endeavor.
Sincerely,
\/Bva
V. Charles Viola
Managing Agent
Lodge Aparment Condominium Association
\*€a*h 174 East Gore Creek Drive, Vail, Colorado 81652 USA
Telephone (y70) 47C50t7 Facsirnile (970) 476-7425
www.rockresorts.comRocrRssoRrs
PROPOSED MATERIAU;
TVoe of MaterialBuildino l4aterials
F: \odaAFoRMs\PERMm\Pbnning\drb-a&ition-l 1-23-2005.doc
Color
Roof
Siding
Other Wall Materials
Fascia
Soffits
Windows
Window Trim
Doors
Door Trim
q
Hand or Deck Rails
Flues
Flashing
Chimneys
Trash Enclosures
Greenhouses'
Retaining Walls
Exterior Lighting
Other
ilotes:
\
a
Please speciff'the manufacture/s name, the color name and number and attach a color chip.
a, O', 'sj ,- r r4Jtr'J 3 6r ' Y
P?4,e7 of14 rLlz3l2m5
PROPOSED TANDSCAPING
Botanical Name Common Name Ouantitv Size
PROPOSED TREES
AND SHRUBS
DCSTING TREES
TO BE REMOVED
MinimumRequirementsforLandscapins: ffifJ:[Iffi:ilffI|!il
Shrubs - 5 Gal.
Tvpe Souare Footaoe
GROUND COVER
soD
SEED
IRRIGATION
TYPE OF EROSION CONTROL
Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.)
F:\cdev\FoRMs\PERMm\Planning\drb-addition-11-23-2005.doc Page I of 14 IU23.P005
Tr,'l*t
Hr
,tri (
{90
/
u/y/ ?rf
j(l-b
;Jj I.tii
i
oz
ts
=eluo-
ooo
(\t
FI
o
(\I
c)oo
(o
ooo
c)<\l
(r,
UJ
IJJl!L
=E[!o-
Gl,l,t----- -g tlcg/s
1,/.,/sb#.1YD
tuJIF
lo
-, aoot 6
r.r,l (o
\\.cor co
6Es,Eol--r-
8rF.io;=+tltJ+r;o gt6l.*t-di=e
t6
ruF
F
FIz
o
z2
oulFozo,26'!
d!
.6
o
=2
ooo
c.!(ug
!c,P+,0,
oo
o(,
ltJ
1Uoz
EffiSErei
; EErg!
; le Eg:
=iE;'=*rs
igEi.#'.E
j-oc
a E;*c
EEg;I
:g'-siFn
o1.()
osf
rJ)$l
ot\
oo
rJ)(O
e
o
-S
co
c
c1t':
r.clt\
|r)ror.()
E
=uJcozo
5o
Y,
uJ
oz
J
J
I
UJJIJJ
oz
=f
J
9z
ouI
=
uJuJt!zo
F
IJJ
u/
;uJ
urez
6|lJ
F
atoo-llJ
z
ul
o
x
Fl!
<t)
tn
uJ
UJt!
ts
=
UJo
J
FoF
oz oc
uJJqJ
(9z
ao-
JC
=I
gJ-
NO|lVn]V
!'Eo
=2 ZtLo ootr ^ 6zg 5 =9F9 OE
tnoE6d f<)zxl!<oq {oEq trEE5 =E.io.i 6g
i9o!)ur S
=(ON
\t z
tr
J
{
Eo
eo
uJ
F
c
uJE,
)
z
Eoo
x
z
tr
qJFJ
=uJz
tllltltl
<,,tzlzOaEur<oo<
=Hx 'r-X.i<z
=z,
9z
-iF
do}E
t_l|lll
t-lll
t]lcclloltoltJlI lrl
UJ
J-)
oau,lzY9
r!
F
z
tr
oz
aJ
3
F
uJ
ooo3
a
i
JI<ltrl2l
zl
.. >l
uloulutzo
=
t!
J
zst =Fo
c}
zY
(7)
Id.
Ls
l-l
@
r{
C\,1c)o
UJ
Eooo-zo
EulV
IIJooFF
E
IJJo-lro
o-oo
I
I!Foz
z
oPz<oo
=z
o- u-
:fi+
=Hg
E
uJ
lt
E9E<al€aE9?L
5E9't*
= IJJ :-E E=o dtrE =*E 56E irE X>e q-
€=
uldtoF
$l
.-1
IIJF
o
E
=Elrlo-zoF()fEFazoo nnn
l-
| (f,ltr)l*
t,"J'Ed=€(d
(Ug)EoJ
(9z
J
I
FoJ
o(7)
LO
J
F
Ld(5ooJ
ui
=z
o-)I
*lFlrlJv,
a
(5
tt1
t-e,UJo
uJ
z
J
U'
=(uJ
lr'(\l
@
oln
UJeoo
=
NrjtoFl
(?,strOltlrb-
(\.t
!c,
o
Eo
ol.Fl
EINI
(|tut!-o
PP(U
=(ust-
=tr
Ed,
-v!
<!t-l
tna
IJJe
T
(t!.
c
=o{J
.:zc(uD
F6
(l,,.:Z
a,an
{JU'
=
=dl!
I
tJ)(\,o-l
^l>l
oluJlq
<liloz3i
FI
<ft\(r)sl'
IrOF\<f
t!
uF
(J
F(J
u.tJL.t
J
L
=tr
UJ
I(\Ior-{
z
oul
=
t!
z3oF
q4
cA
==JCL
lalJJ
J
=tr
o.t.
oz
etUJ
.E
-t
t!oz3oF
uJJ
uJF tr
oz
ciuJ
t!qz
=I =g
oz
ouJ
J
ttoz3oF
uiJ'
UJ
tLuz
=o
F
uJ
=7ot
E
<FGC)
IJJ <zELtI F.42o
JG<o()F
fr3q!troI
z
co
=Jc
x,
=
dE
=3E6
(r
t-r.b
=+E Fo2oC)
<o(4 u)rir llJ:o
I,
A
EED
IA
IJJulu-F
=tuJo-
I
I
I
I
I
I
I
I
tto
ulcclF
zIU'
.93goc)
!6 9.€:oq,l,!
-(E6.9'6E'; a'
€(q.oc3;!1,, o1'F
FE
ED--cOCaod)NCI
-l,8ceetF\q6
P=oo
oDcc(u
E€oo3oooD
:i'5f(D
att c
.e -E
EJ
Eeq9'o-EO.CG
"3di q)i=-sE
j-{,
E6E'=oqt
g8E
c.6 ut
=xYE5E
O YEc-o
9cs
=EPd'5 =c9d
EEE
E E-FbOO
-'E ()
E;9tq! i.Y- do.o o.sFtg,- cLE*e
E6:EE EQr(5=
EE H- o..:rr C(! 0'-5ae
$tf-9R'
'5>.O G:c-=I:E8ia
.i5 s9E o6tr9).r- O ED
-or!
an
uJIuu-F
EG
uJ
F
F
-
=ZZU-o ootr ^ 6zi p
=E.tgc
9C)!4.J2XtL <(c)(LJHA E-8 ;d (\t (,
-
tu
z
tr
8z
F-
uJF
.. >l
lu
lll
IJJzo!
u,o.
J
z
E
o
trFt
E
G.uro.|r
EE2ZE<cLf€8E9=,Lie'EE
=>E dEE b=o dE; >[E 8aE irE ;TEr{€i
utooF
t-'e)
a)(-o
Y
o'2
-.--)
.G.
I X,J
| {-.fi1=\zrE
.=
zo9
=eCDO
=zd8
J
C)z
?
C)ul
=!
{zd
9555o r.u
KE
I
H
:'c-l
t$TFl-4Jtz.t--ei
0{0nrf
t-
25
'ii=z
-
:t
_J'to
a
rll
nNoc
at,-uJE,o
=
IHlu;l\J
lE*lN{
lo.In<t-I\Ilsteolrl<l>
l()
A
5N
14
N-[-'b
JYll,rflr-l
=
I
Irl"t\I
L .,rtsf
Isr
ananul
q-q
-l
=
ldttnf'-x
tK*f"l
fcF\<
sEI
rU-1
Fo
o
INqIo
ur
1l
<l>l
Itlql
zl3l
Fl
\
I\I
I\
.)
sh
g
UJ
J
E
E
E
IlLlllrlNllql--"1
,o2
llJl
JI-l->lttl
zl3lolFI
U
t\\
ric\
t{
0-
Ia0
z
oul
Ja
IIoz;IF
Irf,I
$!
s
=Etr
ci
ouJ
5l<l>l
l!l
zl
=lotH
ll
IF
=tr
.l-l
oluJl
:l
al>llllolzl3lolFI
UJJulF
(r
LlJz3
FC)uJ
=
E
-rO<FE(JuJ<zd,UJF.42
C)
JE<oc)F
F3
S?F',2f
E9P
e3fFd5
C)
6F
F3g6
of. ir
=+tFt-o2 oC)
<c)
Eg
PERMIT NUMBE F PROJECT
o
INSPECTIONTOWN OF
t,lr-t /
r
it'':i t,;JOB NAME
WED THUR
REQUEST
VAIL
r@ eM
DATE
READY FOR
LOCATION:
INSPECTION:
CALLER
TUES FRI
BUILDING:
D FOOTINGS / STEEL
PLUMBING:
O FOUNDATION / STEEL
tr UNDERGROUND
tr ROUGH / D.W.V.
tr ROUGH / WATERtr FRAMING
n ROOF & SHEEB" PLYWOOD NAILING tr GAS PIPING
O INSULATION O POOL / H. TUB
tr SHEETROCK NAIL tr
o tr
tr FINAL tr FINAL
ELECTRICAL:
tr TEMP. POWER
MECHANICAL:
tr HEATING
tr
tr
tr
ROUGH tr EXHAUST HOODS
CONDUIT tr SUPPLY AIR
tr
tr FINAL tr FINAL
frAeeaoveo i:C
bonnecrroru6,.
-
tr DISAPPROVED tr REINSPECTION REQUIRED
DAIE ,,' o. ,, ,'. .' INSPECTOR
/l'-) l-1 {.-- | /U
F PROJECT
READY FOR
LOCATION:
PERMIT NUMBER O
INSPECTION:
JOB NAME
CALLER
TUES
^,
-,.!{"
-INSPECTION REQUEST
VAILTOWN OFp {30
WED THUR FRI 3:od xa @
BUILDING:
tr FOOTINGS / STEEL
PL
tr
:{4
tr
tr
n
UMBING:
UNDERGROUND
tr FOUNDATION / STEEL ROUGH / D.W,V.
{rnnrurruc ROUGH / WATER
rr ROOF & SHEER" PLYWOOD NAILING GAS PIPING
tr INSULATION
tr SHEETROCK
TI
POOL / H. TUB
NAIL
tr FINAL tr FINAL
ELECTRICAL:MECHANICAL:
tr
tr
tr
n
TEMP. POWER tr HEATING
tr EXHAUSTROUGH HOODS
CONDUIT tr SUPPLY AIR
TI
tr FINAL tr FINAL
PROVED tr DISAPPROVED O REINSPECTION REOUIRED
CORRECTIONS:
INSPECTOR
PERM
DATE
BT
/;
I
UM
b
'()I/l
N
I.^l
./l IN
rl
OF
,'1,/,
)
SPECTIONTOWN OF
REQUEST
VAILPROJECT
INSPECTION:
JOB NAME
MON
CALLER
READY FOR
LOCATION:
f-tTUES ,/ WEq, THUR
BI
tr
tr
tr
tr
tr
bdt\tr
ILDING:PLUMBING:
FOOTINGS / STEEL tr UNDERGROUND
tr ROUGH / D.W.V.
tr ROUGH / WATER
FOUNDATION / STEEL
FRAMING
ROOF & SHEER
PLYWOOD NAILING tr GAS PIPING
INSULATION tr POOL / H, TUB
SHEETROCK NAIL o
tr FINAL tr FINAL
ELECTRICAL:
tr TEMP. POWER
MECHANICAL:
tr HEATING
tr
tr
tr
ROUGH N EXHAUST HOODS
CONDUIT tr SUPPLY AIR
D
tr
^^L
O FINAL
./l OVED tr DISAPPROVED tr REINSPECTION REQUIRED
, CORRECTIONS:
,",/''
DATE INSPECTOR
I
SPE
,,1
WED THUR FRI ',
IN CTION REQUEST
TOWN OF VAILPERMITNUMBER OF PROJECT
DATE i ,i :;'t ,loB NAME
INSPECTION:MON
CALLER
TUES PMAMREADY FOR
LOCATION:
BU!LDING:
tr FOOTINGS / STEEL
PLUMBING:
O UNDERGROUND
tr ROUGH / D.W.V.
tr ROUGH / WATER
tr FOUNDATION / STEEL
tr FRAMING
,..' ROOF & SHEER" PLYWOOD NAILING tr GAS PIPING
tr INSULATION tr POOL / H. TUB
tr SHEETROCK NAIL tr
trtr
tr FINAL tr FINAL
ELECTRIGAL:
tr TEMP. POWER
MEGHANICAL:
tr
tr
tr
tr
HEATING
tr
tr
tr
ROUGH EXHAUST HOODS
CONDUIT SUPPLY AIR
FINAL tr FINAL
tr APPROVED
CORRECTIONS:
tr DISAPPROVED tr.REINSPECTION REQUIRED
DATE INSPECTOR
I
SPE CTIONTOWN OF
REQUEST
VAILPERMIT NUMBER OF PROJECT //NAME
--
t t'
IN
t-l ;'/
./
READY FOR
LOCATION:
AM igl-):'' .t' /L/
BUILDING:
tr FOOTINGS / STEEL
PLUMBING:
tr UNDERGROUND
T] ROUGH / D.W.V.
tr ROUGH / WATER
tr FOUNDATION / STEEL
tr FRAMING
ROOF & SHEER
PLYWOOD NAILING tr GAS PIPING
INSULATION tr POOL / H. TUB
tr SHEETROCK NAIL
tr FINAL
tr HEATING
tr ROUGH tr EXHAUST HOODS
tr CONDUIT tr SUPPLY AIR
tr DISAPPROVED tr BEINSPECTION REQUIRED
, CORRECTIONS:
t
DATE INSPECTOR
Rusty Spike Enterpriser .c.
Box l5l7
vAtL, coLoRADO 81657
Home 476.1331 Eusiness: 476-4974
tl! rTI -,rrl.. G -)'i-1.'l
, L-l .l ^i)ra
t, rt n )lJ
ila, l.
'rlj- I r.l
r'
.;l::5
,l r,L
-..'"'i." I,Il
,.- I , j, ,i)
. i -ti\ '1r-
: ,' ' : ,' .. i;. il-;l r.r L l .-:^,
1\- r ,'
-:. 1 _r
EIGNEDN PLEASE REPLY J ilo REPLY NECESAARY
PERMTT
Tr,r"T.
oF lRoJEcr
CTION REQUEST
TOWN OF VAIL
e
SPE
,:- jJ
l
JOB NAME
CALLER
MON TUES THUR / FRI
IN
READY FOR INSPECTION: I:.1ll
LOCATION:
WED
tr FOUNDATION / STEEL
PLUMBING:
tr UNDERGROUND
tr ROUGH / D.W.V.
tr ROUGH / WATERtr FRAMING
r-1 ROOF & SHEER" PLYWOOD NAILING tr GAS PIPING
tr INSULATION
tr SHEETROCK
tr POOL / H. TUB
MEGHANICAL:
tr TEMP. POWER tr HEATING
tr ROUGH tr EXHAUST HOODS
tr coNoutr tr SUPPLY AIR
,APPROVED
CORRECTIONS:
tr DISAPPROVED tr REINSPECTION REQUIRED
DATE INSPECTOR
Gary
Town of Vail Building Dept.Vail, Colo 81657
Gary: Enclosed is the letter of variancefrom the owner of the Lodqe at Vail unit
ENTERPRISES
p. o. box 1517
vail, colorado 81658
L2/22/8s
l_r
/"4
ested
this is not adequate please let me know and I will do
whatever else you require. If you would like to speakwith the owner directly I can either set that up for
you or the owner can be reached at the Lodge. His
name is Bert Kl-ett.
Regarcling the matter of the spacing of the balustersin this unit (+530), I measured those is unit 11527,at the Lodge at Vail-,and found them to be as much aseight inches between the balusters (this is not 8"
on center but 8" between) .
Thank you for your cooperation regarding inspection ofthis unit.
,4.'h'/ /' .//#Ki,4ffi*-
n (h$
fuw" N6N
la
L2/22/8s
Building Department
Town of VailVail, Colo 81557
To Whom It May Concern:
I reepeetfully requeat a variance to the present staircode for the redesign of two steps. These steps arein the stairway of my unit #530, The Lodge at Vail .By redesigning theEe two steps, I have matched them toother existing steps of this winding unit. This changemaintains a continuity with the rest of the stairway.This change improves the flow between the leve1s in the unit.Thank yorlF_(eBert Klett
August 21" 1985
To Whom it May Concern:
In my capacity of Director of Propert ies I have examinedthe plans of renovation/decoration of unit 530 at the Lodgeat Vail.
These pl ans
i mprovements
S incqrel y
su
Assistant Manaqer
CVB:k1g
are approved and we I ook forward to seei ng the
proposed by the owner - Mr" Burt Klett.
174 &r^st C,ore C.."tO.* \hil, Orlorado 81657 303-476-54 Telex 45-0375