Loading...
HomeMy WebLinkAboutB07-0011 Plans pages 1-50N M L O O A4.40 706 4 5 6 7 - A4.40 ;t A�4 8 <4�)46 1 6.9 9 10 2 2 A4.70 A4.50 A4.50 1 12 13 1 is 480 Ak 80 1 4�80 A4� A. 16 18 1920 21 V!-1 137 main street, suite G004 box 5055 edwards, colorado 81632 970.926.2622 rkd@rkdarch.com U) W z UJ W > �o U) z Uj �a QO J 0 W N W Q 3 Q Uo > issue date Permit set 01.29.07 Const. set 04.20.07 Al I Revised Permit 12.14.07 1& sheet title 5TH FLOOR RCP sheet number A2.51 j ob number 04070 issue date Permit set 01.29.07 Const. set 04.20.07 Al I Revised Permit 12.14.07 1& sheet title 5TH FLOOR RCP sheet number A2.51 t; v 0 a w 0 3 r 4 FLOOR PLAN KEYNOTES: / 1 ALL COLUMN WRAPS PED 2 (CB) 2HR EXCEPT WHERE SUPPORTING; ROOF WHI IS IHR - UND. - RE: 950, RE:NOTE 6 2 SCUPPER - RE: Di VAl 7 3 GUTTER 4 DOWNSPOUT 5 EXISTING: 4 HOUR CMU WALL TO EXISTING'; ROOF. W2 ABOVE ROOF. 6 COLUMNS WRAPPED WITH CBI SUPPORTING ROOF ONLY, SEE GENERAL NOTE 12 BELOW. 1 EXISTING: STRUCTURAL COLUMN TO BE FIRE -RATED ACCORDING: TO CE1 AT LEVELS 1,1 t 3, AND ACCORDING TO CEl AT LEVEL 4 WHERE SUPPORTING ROOF ONLY, 8 EXISTING: STRUCTURAL COLUMN WITH EXISTING 2 -HOUR RATMG PER IBC. TABLE 12151(5) - VJF. S EXISTING PRIMARY STRUCTURE. BEAMS INDICATED ALL SUPPORT NO MORE THAN 2 FLOORS OR 1 FLOOR AND 1 ROOF, PER IBC 1142. EXISTING: FLOOR ASSEMBLY, INCLUDING; THESE EXISTING BEAMS, ARE CONSTRUCTED ACCORDING; TO U.L. DESIGN 6523 FOR A 2 - HOUR ASSEMBLY. VIP. 10 WINDOWS SPRINKLERED BOTH SIDE TO AC14EIVE A 1 HR ASSN. IL EXISTING: CORRIDOR TO HAVE WOOD FINISH REMOVED THROUGHOUT, INCLUDING: TO EXISTING: SOUTHWEST ELEVATOR WALLS TO BE RJRRED AS REQUIRED AND A LAYER OF GYP BD APPLIED AND FINISHED. 12. EXISTING: CORRIDOR WALLS TO BE FURRED AS REQUIRED AND A LAYER OF GYP BD APPLIED AND FINISHED. __._ U13 WATERFEATURE: PROVIDE WATERPROOFING BEHIND TILE WITHIN 2 FEET OF RJ55L.E TILE VERTICAL CHANNEL AND WITHIN 1 FEET OF EDGE OF POOL. POOL TO CONSIST OF WATERPROOFING: UNDER SHOTCRETE OR GUNITE WITH TILE FINISH. PROVIDE A 2 LEVEL FLOOR DRAM AT POOL BOTTOM. PROVIDE SPLASH FREE WATER FALL M VERTICAL CHANNEL FROM ABOUT 5TH LEVEL. /9X14. PROVIDE AUTOMATIC, SELF- RESETTMG, OVERHEAD COIL SMOKE SEAL WIT RECESSED M CEILWa �. [gK iLga gwlwzglLJgMA • L THE CONTRACTOR SHALL REPORT ANY DISCREPANCIES CONTAINED WITHIN THESE CONSTRUCTION DOCI1'1ENTS MMEDIATELY TO THE ARCHITECT. 2. DO NOT SCALE DRAWINGS. ANY DISCREPANCIES M DIMENSIONS SHALL BE POINTED OUT TO THE ARCHITECT AND RESOLVED PRIOR TO C 11ENCEMENT OF WORK 3. ALL DOORS HAVE 4' RETIRN OR ARE CENTERED WITHIN WALLS, UND. 4. ALL DIMENSIONS ARE FROM FACE OF STUD, FACE OF CONCRETE, OR CENTERLINE OF GRID, UND. 5. PROVIDE ALL NECESSARY BLOCKING; M STUD WALLS AND CEILINGS FOR BUT NOT LIMITED TO, FHA BATHROOM TOILETS, BATH ACCESSORIES, CEILING: AND WALL MOUNTED ELECTRICAL FIXTURES, SHELVES, CLOSET RODS, CABNETRr, BUILT -NS, AND CONNTERTOPS. 6. ALL UNITS HAVE TWO (1) FHA SPECIFICATION TYPE 'B' BATHROOMS (ONE (1) POWDER ROOM AND ONE (U MASTER BATHROOM) AND ACCESSIBILITY FOR KITCHENS AND LAUNDRY APPLIANCES. 1. ALL FHA BATHROOMS HAVE REMOVABLE CABINETRY AT SINKS FOR KNEE CLEARANCES. 8. PROVIDE 6' STUD WALLS AT ALL POCKET DOORS, PLUMBING WALLS, AND AS SPECIFIED BY ARCHITECTURAL OR STRUCTURAL DRAWINGS. 9. REFERENCE DOOR AND WINDOW SCHEDULES ON SHEETS ASM THR1J ASO4 FOR SPECIFIED SIZES, TYPES, MATERIALS, AND FIRE RATINGS. 10. REFERENCE BLSG SECTIONS FOR SYSTEM NOTES IL REFERENCE ENLARGE PLANS FOR MORE EXTENSIVE INTERIOR WALL TAGS 12. ALL COLUMNS WRAPPED WITH FIRE RATED ASSEMBLIES. RE: A95- SHEETS FOR DETAILS. C52 UND. ON ALL FLOORS EXCEPT 5TH WHICH HAS CBI - IHR THROUGHOUT AND N GARAGE WHICH HAS C53. B. OCCUPANCY IS NOT PERMITTED N THE EXISTING PORTIONS OF THE BUILDING DURING CONSTRUCTION AND DEMOLITION, EXCEPT AS APPROVED BY PHASING: PLAN. 14. ALL EXT WALL W2- NON -RATED UND. ALL NT WIT WALLS W4- NON -RATED UNTO. "�� —�-� 15. ALL FLASHING TO MEET OR EXCEED SMACNA STANDARDS. PLAN LEGEND 1 EXISTING; TO REMAIN - NJ:C. EXCEPT AS NOTED OR PATCHED AS REQUIRED NEW WALL TNT ---./' WIT INTERIOR WALL, W4, TO EXTEND UP TO UNDERSIDE OF STRUCTURAL DECK ABOVE EXISTING WALL TO REMAN SH011N LIGHTER DROPPED SOFFIT FOR MEC 4 - Cl FAI 19 RESIDENTIACWITS, LOCATE DROPPED CEIILINGS AS HIGH POSSIBLE AFTER ACC,OMOCAl TONGUE AND GROOVE CEILING - C2. HT NOTED ON PLANS STANDING SEAM MTL ROOFING - 12:12 SLOPE UND. D OO R Cl ALL DOM -SEE SHEETS AWO-AW AN D WINDO :a RED O WINDOW TAG -SEE SHEETS AWO-AS3§ --EK] WALL, ROOF, FLOOR ASSEMBLY TAGS -SEE SHEET A4.10 FOR ASSM 2 _ i _ A4.40 A4.40 A4.70 �1 3 4 a S 7 0 E s I � t { { 2 1 2 A4.70 A4 A4.50 It X12 �1 �3 X14 { A4.80 A4.80 A4.60 A4.60 71 o � { 30 Kom t on n Top of deck Elev. +152' -2" Scale: 1/8' = IV 137 main street, suite G004 box 5055 edwards, Colorado 81632 970.926.2622 rkd @rkdarch.com V I 1 Z W T Q .i LL . U) W r M • STAMP OF RECORD: Ak job number 04070 issue date Permit set 01.29.07 Const. set 04.20.07 Al add 7 09.10.07 Revised Permit 12.14.07 sheet We ROOF PLAN sheet number W L .J II III III III III III III III � III III II III III III III I!I III III III III II III III III III III III III III III �--- EXISTING 2 HR SOFFIT EXISTING V- SHAPED PIER -- GIRDER — SLAB ON MTL DECK EXISTING WINDOWS IN FOREGROUND. INFILL WINDOWS WITHIN 10' -0' OF BRIDGE CONNECTION WITH 2 HR RATED SHAFT WALL BEHIND WINDOWS, SPA 0 i NEW BRIDGE CONNECTION 45 min DOOR IN NEW 2 HR WALL INFILL IN 2HR CONC WALL. INFILL GARAGE OPENING WITH 2 HR CMU AND STUCCO TO MATCH EX ON OUTSIDE FADE EXISTING SPA LOBBYI &!4e g Section _ 2HR FIRE SEPERATION WITHIN 10' -0' OF BRIDGE IN ALL DIRECTIONS CASCADE RESIDENCES T/0 CONC O IL 0 2ND FLR _ ELEV.- III' -9' T/O CONC e 1St FLR. ELEV.- 100' -0' _ 5/0 SOFFIT ELEV.- 123' -6 L/2' ' EXISTING CASCADE SPA ' T/O CONC ELEV.= 112' -6 1/2' ELEV.- 115' -6 1/2' T/0 CONC ELEV.- 112' -6 1/2' SHAFT WALL INFILLED BEHIND WINDOWS WITHIN 10' OF BRIDGE STANDING SEAM ALUM STOREFRONT TO MATCH CASCADE STUCCO RESIDENCES LINE OF 2HR FIRE RATING CLEARANCE SIGN - -- v > CONCRETE PIER -- EXP JT COVER -' EXISTING V- SHARD -- CONCRETE PIER BEYOND ROADWAY - ' EXISTING ' PARKING GARAGE ELEV.= 123' -6 1/2' id qe Elevatio O SHAFT WALL IifILLED BEHIND WINDOWS WITHIN 10' OF BRIDGE ELEV.- 123' -6 V2' EXISTING CASCADE SPA T/O CONC / STUC e CASCADE RES. ELEv.- 111' -9' - EXISTING PARKING GARAGE -- — - -- -- CONCRETE PIER EXISTING V- SHAPED CONCRETE PIER — SPA ENTRY BEYOND GRADE BEYOND -- -- DRIVEWAY STANDING SEAM MTL ROOF CASCADE RESIDENCES STOREFRONT TO MATCH CASCADE RESIDENCES p p ii & _ �e levation E EXISTING STANDING SEAM METAL ROOF -— — LINE OF 2 R ATING AT - - - - -- -- __ - _ _ WALLS FLOOF�5 SPA 3RD OPENINGS, AND EXISTING WINDOWS - -- - -- 0 LEVEL EX 2HR RATED WALL TO EXISTING SOFFIT - — -__ -- -- - -- - -_ BE VERIFIED IN FIELD r OIL B/O SOFFIT _ f - NEW NON RATED WALL TO ALIGN ELEV.= 123' -b 1/2' ' - - - -- WITH EX WALL ABOVE. SPA I WINDOWS TO MATCH SPA WINDOWS. I ¢ - } FURRING TO COVER BEAM 0 I ,7 I EXIST PIER TO REMAIN � EL CONC ELEV.= 112' -6 1/1' SPA GAkACsE ' ' EXISTING EXISTING OPN'G TO BE FILLED IN CONCRETE PIER - - -- ^� WITH 2 HR CMU AND STUCCO TO CONCRETE _ MATCH EX ON OUTSIDE FACE, PIER RES IST FLR Bridge Connection Partial Sec tion Swe:11r =1b' WALLS WITHIN THIS BOUNDARY ON EXISTING STRUCTURE MUST BE RATED 2 HOURS. EXISTING WINDOWS AND OPENINGS FILLED IN WITH 2 HR RATED IWILL 1 A211 dge Ele�ion I (�)�!. 8'= 1D' tp on� I RE5IDENGE5 I I I FR OF BRIO FF, OF 2ND 'TETAL DECK 3TL P,ENT FURL IN 'iIQDER CONCRETE ON "IETAL DEGK Scale: 1 /4' =,b' 1 137 main street, suite G004 box 5055 edwards, Colorado 81632 970.926.2622 rkd @rkdarch.com Uj U z LU Ljj >_ �oo w Qo =o WNW Q V o> , M v/ � Q U STAMP OF RECORD: issue date Permit set 01.29.07 Const. set 04.20.07 A Revised Permit 12.14.07 sheet title BRIDGE DRAWINGS sheet number A2,70 Dimensions at Bent 0 0 0 a` w v 4 FLOOR EXPANSION JOINT COVER W/ NECESSARY MATERIAL FOR 2 14R RATING WALL EXPANSION JOINT COVER W/ NECESSARY MATERIAL FOR 2 HR RATING r W 3 5/8' _ LOW WALL BELOW COVERING BEAM Bridge Slip DIU w ; 1 1. -' 1 6! Column Window Dtl aSHING BELOW TRIM BELOW CKERROD AND SEALANT -F ADHERING MBRANE TO EXTEND ER PAW FLASHING SIDE MS -F ADHERING SILL MBRANE TO EXTEND 9M UNDER PAN k5HING OUT TO FACE OF ICCO, DOWN FACE OF ICCO BEHIND FLASHING 2UCT BENT 916' ZINC SHEET >HERED AND SCREWED STRUCTURE UM STOREFRONT U Scale: 3' =1.T PANEL CLIP W/ FASTENERS PER MANUFACTURER SEALANT TO CLOSE END OF PANEL CUT AND FIELD BEND PANE SAM. OVER FLASHING 2' STANDING SEAM FASCIA WITH TRANSITION DETAIL AND FLASHING PER ROOFING MFG GYP BD SHEATHING (2) LAYERS BUILDING WRAP DRIP EDGE DETAIL PER MFG EXT GYP SHEATHING I SOFFIT VENT I BACKERROD AND SEALANT, TYP SUSPENDED G.B. CEILING (p 4 ! .3- ave DU at Bidge T.0.G.e = r� EL 120'-6 RIDGE VENT PER MTL ROOFING MANUFACTURER -- - 2' STAND ING SEAM MTL ROOF (CLASS A) ON HIGH TEMPERATURE MODIFIED BITUMEN MEMBRANE (GRACE ULTRA OR EQUIVALENT) ON 1/2' DENS DECK. ON 1 1/2 MTL DECK ON STL FRAMING. STRUCTURAL STEEL FRAME, 1 � 4 / ° - SNOW BRAKES: SPACING PER A2•11 100 0, SMACNA REQUIREMENTS. •.� - — __ SUSPENDED GB. CEILING W/ R -30 BATT INSULATION AND VAPOR � BARRIER ABOVE G.B. � ' i y \ y 1 ` - - SOFFIT VENT IN EXT GYP SHEATHING. S.A.M. OVER FRAMING AND UNDER PAN FLASHING AND SILL FLASHING - DRIP EDGE DETAIL PER MFG SILL FLASHING W/ DRIP _ EDGE TO MATCH WDWe ``�- -�_ 2' STANDING SEAM FASCIA WITH TRANSITION DETAIL PER WOW W/ SIDE AND END ROOFING MFG DAM PAN FLASHING - S.AM. OVER DAMS AND INTO PAN FLASHING AT SIDES N WD TRIM a2 tl R -21 BATT INSULATION Wl VAPOR BARRIER ON INSIDE OF GB. P -LAM ON 1/2' GATT ALUM STOREFRONT WDWS INSULATION CONNECT STUDS WITH 3 5/8' MTL STUD AT EA AND PROVIDE 3 BLOCKING UNDER ,x211 PLYWOOD AND WDW _ ' -_- WD TRIM Scale: 3' = V-V I ZINC BASE -- -- - GIRDER - - -- — I : V2'x1' WD TRIM - -- I � CARPET FLASHING AND STUCCO. BOTTOM WEEP SCREED. 2 LAYERS OF BLDG WRAP (WRB) OVER WEEP SCREED AND FLASHING i' BENT STEEL PLATE; BRIDGE EDGE TRIM i . r P V Bridge Edge DU gw",. , = 14 r- � �• N T .O. C EL 112' -6J' , l 2ND i FLR 2 a2il �, STRUCT GIRDERS R -21 BATT INSULATION W/ VAPOR BARRIER ON INSIDE OF GB. Y- P -LAM ON 1/2' PARTICLE BD SUBSTRATE ZINC BASE FIN FLR f _.% ti`s V .0 U) W U z UJ UJ >_ �oo U) w� � QO z0 UJ N U Q � Q Vo > r^ M vJ r' Q U job number 04070 issue date P - �,4+ { ;M1 r E r iTl �t .r .Lis' �s } / CONC ON MTL DECKING — - -- I' STUCCO ON 2 LAYERS OF BLDG PAPER (WRB) ON 5/8' EXT GYP I SHEATHING 2 I/2' MTL STUD FRAMING W/ RIDGID _ — -- _ Revised Permit 12.14.07 INSULATION 00,111,111111111 11000001wwttw,44141� BENT STEEL PLATE, BRIDGE EDGE TRIM /13\ sheet OW BRIDGE DRAWINGS sheet number Bridge Section A r1 Wdw Sill at Bridge 137 main street, suite G004 box 5055 edwards, colorado 81632 970.926.2622 rkd @rkdarch.com u n 0 v 0 3 m Q 00 N 01 O 0 N 7 N 0 0 I s 0 CL 0 Z z h ?A. i2oo Aed 6th Floor 4th Floor 132' -9' 3rd Floor 122' -3' Garden L � eve — Lower Garcia 82' -0' ELEVATION KEYNOTES: 1. PRE - FINISHED STANDING SEAM MTL ROOFING 2. PRE - FINISHED MTL. COPING AND FLASHING 3. ZINC COL TRIM 4. WOOD TRIM 5. ALUM CLAD WOOD WINDOWS 6. ALUM CLAD WOOD SLIDING DOOR 7. ALUM CLAD WOOD FRENCH DOOR 8. STUCCO 9. ALUM STOREFRONT 10. CUT STONE 11. MTL RAILING 12. GUTTER AND DOWNSPOUTS, TYP. AT ALL SLOPED MTL ROOFS 13. RELOCATED BRIDGE (RE. A2.70) 14, EXISTING BRIDGE TO REMAIN 15. GRADE 16. NEW CMU SITE WALLS W/ CUSTOM STEEL GATES 17. LOUVER 18. OVERHEAD DOOR 19. EXISTING OVERHEAD DOOR TO REMAIN 20. CUSTOM METAL GATE 21. WALL SCONCE 22. DECK LIGHTS ARE BEHIND LOW WALL, TYP. 23. SKYLIGHTS 24. OVERFLOW SCUPPER 25. SLIP / EXPANSION JOINT AT BEAMS, CJ AT OTHER 26. CONTROL JOINT O L TD. Roof Deck 152' -2' 5th Floor 142' -9' 4th Floor 132' -9' OL 3rd Floor 122' -3' Ind Floor 111' -9' p o Garden Leve OL Lower Garde 82' -0' GYIC Tn PGMAW Scale: 1W =17 North Elevation scale: 1/8' =17 137 main street, suite G004 box 5055 edwards, colorado 81632 970.926.2622 rkd @rkdarch.com 0 Uj U z Uj Uj >_ Quo _o U)Z� UjQo =o W NW Q W J o > 0 T r^ M V! TM U job number 04070 issue date Permit set 01.29.07 Const. set 04.20.07 Al Revised Permit 12.14.07A9 A___ sheet title ELEVATIONS sheet number A3.1 0 M U O a v w 0 3 m s a 0 0 0 N V' N 0 0 a` v a 0 t v Q r a N Q Y ELEVATION KEYNOTES: 1. PRE - FINISHED STANDING SEAM MTL ROOFING 2. PRE - FINISHED MTL. COPING AND FLASHING 3. ZINC COL TRIM 4. WOOD TRIM 5. ALUM CLAD WOOD WINDOWS 6. ALUM CLAD WOOD SLIDING DOOR 7. ALUM CLAD WOOD FRENCH DOOR - 8. STUCCO 9. ALUM STOREFRONT 10. CUT STONE 11. MTL RAILING - 12. GUTTER AND DOWNSPOUTS, TYP. AT ALL SLOPED MTL ROOFS 13. RELOCATED BRIDGE (RE. A2.70) 14. EXISTING BRIDGE TO REMAIN 15. GRADE 16. NEW CMU SITE WALLS W/ CUSTOM STEEL GATES 17. LOUVER 18. OVERHEAD DOOR 19. EXISTING OVERHEAD DOOR TO REMAIN 20. CUSTOM METAL GATE 21. WALL SCONCE 22. DECK LIGHTS ARE BEHIND LOW WALL, TYP. 23. SKYLIGHTS 24. OVERFLOW SCUPPER 25. SLIP / EXPANSION JOINT AT BEAMS, CJ AT OTHER 26. CONTROL JOINT - I EVIOU5 INEUJ c� .i 3n Level 2 West Elevation Scale:1 /8' =1 nD e� w w v 137 main street, suite G004 box 5055 edwards, Colorado 81632 970.926.2622 rkd @rkdarch.com co UJ 0 z LU UJ > . 0� • • UJ UJ • 1 ' • UJ U 0 U) 0 • M job issue date Permit set 01.29.07 Const. set 04.20.07 Al Revised Permit 12.14.07 Lg `j sheet tide i ELEVATIONS sheet number A3,20 u 0 CD CL m O LL L 01 r v Q 10 11 I I 3' -6' YoND SRW RESISTANT METAL :S WT IN SEALANT E TO RBUN CLEAR . VStER A SIDE OF 3 -518' MtL Sill detail at Garden Level Lobby Scale: T= 1'-0' Col detail at Covered Walkwal ZINC CLADDING ON SAM. SAM. OVER SILL FLASHING, STOP AT SEALANT STONE CAP: • ON FLASHING • ON SUPPORT ANGLE STONE VENEER BELOW STONE CAP: • 1' AIR SPACE • 2 LAYERS W.R.B. UNDER SUPPORT ANGLE • 5/8' GYP SHEATHING • STUD FRAMING 7 - 1 & used STONE CAP BELOW STONE VENEER BELOW STONE CAP: • I' AIR SPACE • 2 LAYERS W.RB. • 5/8' GYP SHEATHING • STUD FRAMING ZINC CLADDING ALUM STOREFRONT TUBE FRAMING (DASHED ABOVE, LIGHT ABOVE t BELOW) ATTACH AS RER'D TO ZINC CLAD COLUMN, STUCCO PIER AND GYP SHEATHING LID. SAM. OVER GYP SHEATHING ON MTL STUD FRAMING Col Wrap at Covered Walkwa 7 NW Partial Elevation Scale: 114' =1b' SOFFIT - ° 1 SIGN CONNECTION TO SOFFIT COPPER PANEL SIGN ___ _ _ _. _.- .. _ -__ 8X12 ZINC -CLAD COLUMN IN FOREGROUND ,I II I STUCCO OR STONE VENEER COL BEYOND (SEE 1/A330 FOR LOC OF 4 STONE VENEER COLS. I ( _._- r STUCCO WALL BEYOND — _. _ STONE VENEER € I CONG PLINTH- �1 Walkway Elevation l %) STOREFRONT WINDOWS 12 13 14 15 16 17 18 19 20 21 2 3 24 25 27 28 29 30 31 32 ZINC -GLAD COLUMN ✓ I x I I STONE CAP SIGN BEYOND ✓ ✓ i i. _ ' ✓ I E STUCCO I I cn : k i 1 ! f ti m ! � I f € € - i I _ - y-~ COPPER CLAD PANEL !'g___ - i _- -� � � �" - ERG SPACE 1 _ GONM .. • ..___.__ -._._ _. ....... t.... t SIGN STORE FRONt COPPER CLAD PANEL I .... , . _ 8X10 ZINC -CLAD j R L COLUMN ...^ iT , I .; ::: i CoPPE CAD � � _ _� !__ � f , �� ! _ /'- _ 8x12 RGIAL SPADE SIC-AN ZINC -CLAD COLUMN i _, , - PANEL _ COPPER GLAD ! �__- _-_-_. ____ GLAD ! STONE . ...:....:.:.... COLUMN PANEL MAIN 6 -4 - 8X12 ZINC ; N SIGN 771 1 : -.: :. - ;.:'::, "•�.' � � _ Btl LDING SIGN VENEER f I r - ALUM FTd 1'G _ �___ - SNP a33o STUCCO CLAD ALUMINUM FRAME TO HATCHE - :' MATCH STOREFRONT - - -� STONE JOINT .:.... COPPER CLAD .:.;.,: COLUMNS � I ! € ! 5T CAP - -- WINDOWS ONE - - - -- I _ ; ._: "��:- PANEL MAIN - -- - - -- - - -- BU LD GN •�� _ - STONE VENEER 3' -T 5 ' -10' 8 ' � 5' -10' 3' -0' 3' -6' Z' -9' S' -10' 2' -9' 3' -(, ' i 2'-31' F7 2'-21' & Arcade Elevation lw 114' =1'0• 137 main street, suite G004 box 5055 edwards, Colorado 81632 970.926.2622 rkd @rkdarch.com UJ U z LU UJ >_ pro _o U) w �a WQo �zo Wye Q3a V o > '^ M V� � Q U STAMP OF RECORD: job number 04070 issue date Revised Permit 12.14.07 sheet title ENLARGED ELEVATIONS sheet number 7 A3.30 Garden Level Lobby Entrance