Loading...
HomeMy WebLinkAboutDraft Chapters 4, 5, 6 - Plan submittal 061208i j~ I II i I ly I ~y ~I, I I44II I phi y( II I 'II ~ '0 AOL f a ` "tam • Vim" "~1 p. a~l.aea ^ try iJa5 4w I 07caw 4 &*T "Community participants expressed a strong preference for a locally relevant development serving the local community as well as destination visitors " &0&7% 4 Lionshead Redevelopment Master Plan 5.1.2 OPRA F r 6 •t2-o8 The Open Hospitality Partners & Hillwood Capital [Open I Hillwood] Partnership The Town of Vail Conference Center The Vail Conference Center will be designed in a way to ensure that it will be similar to or better than the following facilities in terms of quality of design, materials, finishes, furnishings, and equipment: Banff Centre, Monterey Conference Center, Snowmass Conference Center, Telluride Conference Center, Keystone Conference Center, and Whistler Conference Center. The quality of the finishes incorporated into the Ballroom will be appropriate for the Town's finest formal dinners and social functions. The entire space will have an attractive and durable carpet and appear like a high-end ballroom instead of less attractive exhibit space. The movable partitions will be high quality, providing excellent sound attenuation between partitioned spaces. The space will be outfitted with sophisticated sound and audio-visual systems. The Town of Vail Conference Center facilities program has been created to maximize flexibility in order to be in a position to accommodate the widest range of types and sizes of events while continuing to limit the size of the facility to 34,000 as contemplated in the Development Agreement. The centerpiece of the facility is a 16,000 SF ballroom that will be divisible into a number of different configurations, including 4,000 SF and 8,000 SF meeting and banquet spaces, as well as eight separate 1,000 SF breakout spaces. The Conference Center facility will also include a 3,500 SF, 200-seat auditorium that will include fixed, raked seating, and a sound and projection booth. Additionally, the Conference Center will include three, approximately 800 SF dedicated hard-walled meeting rooms. If an event requires more breakout space than is provided within the Conference Center, additional meeting space in the two hotels can easily accessed from the Conference Center. The St. Regis Hotel function space, located a short walk away and on the same level as the main Conference Center ballroom, includes a 3,600 SF ballroom which will be divisible into three 1,200 SF rooms plus two approximately 800 SF meeting rooms, and another approximately 600 SF meeting room. The W Hotel function space, located a short distance away and one level above the main Conference Center ballroom, includes a 3,300 SF ballroom which will be divisible into three 1,100 SF rooms plus three approximately 800 SF meeting rooms, a 1,500 SF screening room, and another approximately 600 SF meeting room. By augmenting the approximately 3,000 SF of dedicated Conference Center breakout space with additional hotel meeting space that is easily accessed directly from the Conference Center, we are able to include both the 16,000 SF ballroom and the 3,500 SF Auditorium, continue to limit the total square footage of the Conference Center to 34,000 SF, and be able to provide for events that might require up to another 16,000 SF of breakout space which is separate and distinct from the main ballroom. The main St. Regis Hotel Kitchen has been enlarged to nearly 8,000 SF in order that it can function as the main hotel kitchen and as the banquet kitchen on those occasions that food will be served at the conference center. There is access from the kitchen by means of a back of house corridor, enabling servers to access the ballroom and meeting rooms without going out into the public pre-function or circulation space. Additionally, a 1,500 SF warming kitchen has been located immediately adjacent to the main ballroom in order to facilitate final preparation of plates prior to delivery to the guests. DR,477 664mace n~ - e 04 LionsHead Parking Structure Redevelopment The Open Hillwood Partnership page " W: 4240 Froject Plan Submittal Level G1 (seepage 13 for Conference Program Summary) LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership ToV Conf. ; St. Regis LEGEND 0 BACK OF HOUSE Q CIRCULATION CIRCULATION-VERTICAL Q RESIDENTIAL UNIT Z);Z+707 page 2 Q FRACTIONALS Q HOTEL Q W SUITES Q PUBLIC Q PARKING - HOTEL/CONDO/VALET Q PARKING -PUBLIC Q PARKING -SPEED RAMP Q PARKING - SERVICE TRUCK/ECO BUS 0 RETAIL Q TRANSIT HUB Q TOV CONFERENCE 0- 32' 64' 4240 Project Plan Submittal y 4V Loading : ToV Conf. Parking Area Floor Plate Elevation: 8,154' All Other Floor Nate Elewtions: 8,157' Garage Level a Level G2 (see page 13 for Conference Program Summary) LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership LEGEND ToV Conf. ; St. Regis Q BACK OF HOUSE Q FRACTIONALS Q CIRCULATION Q HOTEL CIRCULATION-VERTICAL 0 WSUITES 0 RESIDENTIAL UNIT 0 PUBLIC V;Z.4~77 page 3 0 PARKING - HOTEL/CONDO/VALET Q PARKING -PUBLIC Q PARKING-SPEED RAMP 0 PARKING - SERVICE TRUCK/ECO BUS Q RETAIL 0 TRANSIT HUB 0 TOV CONFERENCE p 321 641 w -7- 4240 Project Plan Submittal ToV Conf. St. Regis W : ToV Conf. AA ToV Storage/ Cont. Mgmt. Torn ~f Vail ballroom EL = 8154' I ~r t, Board Center Room { :LJ30W St. Regis Kitchen EL = 8173' Upper Retail Street EL = 8155' • 9n Conference - Level G1 (see page 13 for Conference Program Summary) The Open Hillwood Partnership Z);Z+77 page 4 EL = 8171' St. Regis Lower Terrace BB 1, 66apwwe 6ewt - 6&Vth 04 ' 4240 Project Plan Submittal ToV Conf. ; St. Regis BB, St. Regis'. B. 0. H. St. Regis B.O.H. .ecture Ballroom kl all EL = 8154' St. RE is Meeting Rooms Pre-fun ublic parking _ do_wn -_top' . . H,tir hNri~hpp hA pp YYrr BOH Retail &*wow &Mtm - &A&rm 04 4240 Project Plan Submittal Section `AA' Looking Through Town of Vail Conference 2);Z477 Lions) lead Par~l„y Struciure Redzve opmenll. The Open I Hillwood Partnership page 6 4240 & 0~ 04 Project Plan Submittal Section through Conference and Transit Center LionsHead Parking Structure Redevelopment The Open Hillwood Partnership The Transit Center serves as a connection between the Conference Center and the public pedestrian and vehicular circulation... 'It will be important that the civic facilities complex be connected to all three circulation networks in Lionshead vehicular, pedestrian, and public transit." Lionshead Redevelopment Master Plan 5.1.3.1 Z);Z+77 page 7 &*team &Arm 4240 &aA&n p¢ Project Plan Submittal 47, ■ ■ l 1 - I - _ To Town of Vail From Porte Conference Public Circulation Z);Z477 LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership page 8 III ' i I' M~ III 'I I j I I I I Ij I 1 ; u I i From Porte i . II' `r I III 4 I ~ ~j III i III 41 i ~ ; l ~ i ~ ~I I Cochere lI!° I I I II I 1 1 I I i 1•~ ~ _ I - -e _ III I I I ( I ' ~ of ' II, 11 1 ~ I I i l ~ i t r"'. 1,1 14 III ' I III III { ; I U~ ■ I III i III III II ! it 4, 1 pl 11111 I I ~ I I+ . I iJ i I ■ ~i _ I III I III III ICI ! I III X11 1 I , ~ Ili III III I i I I Ni i I I li~l ■ ~ i l i I I of ~ o , . I ~ I . III I I !T ■ ~ i I To Upper m~ I y hi , , i I II III I I I'' ' ; Terrace, Pre- " ■ 4 41 I iI i V ■ function + ~ I Porte I, I I ;i III I i I 1' I Cochere I I~I - ii I~ I I C I Ir t i yl I~,T,~-v . 1. I I I I 6 I 11 I II { I I j I I { I I I ~ 1 1 I I I I I 1 it " 11 - 1 1~ ,yr Retail i To Upper Terrace + re-function • , tillage, Retail and Dobson Arena X04 4240 " roject Plan Submittal From Loading / Receiving Service CoMO' Bat LionsHead Parking Structure Redevelopment The Open ( Hillwood Partnership %);Z4707 page 9 4240 6lr~ p¢ Project Plan Submittal Service Circulation - Level G2 Entry from Pre-function Level uonsHeaa Larking Stru~iure Redeve opnrien The Open Hillwood Partnership V;Z.4~77 page 10 , iPI 604 4240 "roject Plan Submittal I Iki (-r 24' there is agrowing need for additional conference space in Lionshead, especially as the local economy seeks to diversify and provide a wider range of destination resort activities in addition to skiing, " Lionshead Redevelopment Master Plan 3.2.4 Town of Vail Conference - Main Ballroom Z);Z4;77 LionsHead Parking Structure Redeveiopmeni The Open Hillwood Partnership page 11 y 1 t " 04 - 4240 roject Plan Submittal From Town of Vail Pre-Function LionsHead Parking Structure Redevelopment The Open Hillwood Partnership Z);Z,4;77 page 12 4240 - 6&sA&4 04 Project Plan Submittal Town of Vail Conference Center Program Comparison Description Program Dated 03.24.08 Current Plan Ballroom 16,000 16,005 Meeting Space A 1,000 815 Meeting Space B 1,000 815 Meeting Space C 1,000 815 Meeting Space D 1,000 0 Pre-Function Space 4,750 5,350 Storage 2,000 2,000 AN Storage 500 240 Warming Kitchen 1,530 Auditorium 3,500 3,465 Pre-Function 875 1,690 Storage 400 400 AN Storage 250 240 Restrooms 1,000 1,100 Business Center 500 600 Conference Manager 600 440 Board Room 500 Circulation 5,891 Total 34,375 41,896 Breakout Spaces St. Regis Hotel Breakout Space Meeting Room #1 795 Meeting Room #2 795 Meeting Room #3 620 Board Room 500 Subtotal 2,710 W Hotel Breakout Space Studio #1 800 Studio #2 800 Studio #3 800 Screening Room 1,500 Board Room 600 Subtotal 4,500 ToV Breakout Space 2,445 Total Available Breakout Space 9,655 Ballroom Capacity Standing Room Only Lecture Banquet Program Summary Development Agreement September 2007 Project Plan Jul 2008 Ballroom 17,500 16,005 Auditorium 3,465 Pre-function / Breakout 8,000 9,985 General Circulation included 5,891 Back of House / Support 8,590 6,550 Total 34,090 41,896 2);Z+707 66o4awwe &a&n - j?AaA&t 04T 13 REL. 4240 Project Plan Submittal LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership page 4 •7rr„ fWMMM, l M ~ tl a sC ' s. . ! i ~ $f Y e" c "The structure is conveniently located between the civic center on the east and the main portal to the Lionshead pedestrian mall on the west, No other location offers visitors such 65 ease of access " LRMP 4.8.3.3 e&A&I't DRAfT 6•n•og The Open Hospitality Partners & Hillwood Capital [Open I Hillwood] Partnership f. y 1 1 low l rr 1 I I I I 4 I I a y ~l 1.70 R.O.W. south frontage road I I ' I r ~I /j garage access plan ru , r , The Open Hillwood Partnership residences / hotel valet operations public parking high bay service and delivery page 4240 project Plan Submittal 1 %.1 use diagram LionsHead Parking Structure Redevelopment The Open Hillwood Partnership onto OD;Z+77 paj&.,~ & page 2 y' 4240 Project Plan Submittal parking count level G2- loading and bus only level G3- 386 private stalls 160 short term stalls level G4- 571 long term stalls level G5- 665 long term stalls level G6- 369 long term stalls Description Number of Units Parking Requirements per Unit Number of Spaces Required Number of Spaces Provided Additional Information Private Parking Required by Zoning Hotel Uses 240 keys .7 per 1 key 168 160 W + 80 SR Dwelling Units 111 units 1.4 per 1 unit 155 53 W+ 58 SR Fraction Fee Units (25 fractionals) 22 units .7 per 1 unit 16 22 SR Employee Housing Units 0 Private Meeting Space 11,885 sf 1 per 330 sf 36 6085 W + 5800 SR - hotel conf spaces Spas 17,960 sf 1.3 per 1,000 sf 41 7500 W + 10,460 SR - hotel spas Total Private Parking 417 Parking Reduction 17.50% 73 per 12-10.12 for 701.800 parking spaces Total Private Parking After Reduction 344 386 Public Parking Required by Zoning Retail 75,000 sf 2.3 per 1,000 sf 173 private stalls in public garage Restaurants 13,210 sf 1 per 250 sf 53 (1770+2450+2400+3700+2890) within hotels Civic Center 22,990 sf 1 per 165 sf 139 (3940+15930+3120) Not-Far-Profit Office Space 3,000 sf 2.3 per 1,000 sf 7 public stalls Information Center 2,400 sf 2.3 per 1,000 sf 5 public stalls Vail Recreation District Space 2,500 sf 2.3 per 1,000 sf 5 public stalls Total Required by Zoning 382 Parking Reduction 17.50% 67 per 12-10-12 for 701-800 parking spaces Total Required by Zoning After Reduction 315 315 Replacement Longterm 1,290 1,290 Short term 160 160 Total Replacement Stalls 1,450 1,450 1150 replacement, 300 Gin to Town Total Public Parking 1,765 1,765 Grand Total Parking (Public+ Private) 2,109 2,151 VR477 ;V41&V sr4uc~ / zQa~ & orl&" - &A&&4 5 LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership page 3 RE i 4240 Project Plan Submittal Entn Access to G3 level Access to G4 level speed ramp diagram u ; ctn. F - r~ ~r The Open I Hillwood Partnership Access to G5 level y I and I' G6 Level page 4 4240 Project Plan Submittal I"1NVGJJ lV G5 level Entry from Frontage Road (East) level 01-Porte Cochere -2 hotel shuttle drop-off residences I hotel valet operations ~ M' 01 level - flow diagram LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership pedestrian stairway to retail level and Conference Center Z);Z.477 page 5 4240 - eltoth 5 Project Plan Submittal level G2 -5 loading/delivery bays -5 eco-bus drop-off stalls -3 hotel shuttle drop-off Valet to hotels above Freight elevator Down to G3 - shuttle parking loading dock s transit long term exit/entry shoes x~ntry eco bus G2 level - flow diagram LionsHead Parking Structure Redevelopment The Open Hillwood Partnership pedestrian exit to upper retail ZMP~? page 6 south frontal proposed derpass sly term ®n ! . Retail loading dock Vy exit eco bus exit residences / hotel valet operations public parking high bay service and delivery 4240 Project Plan Submittal valet parking entrance level G3 -386 valet stalls -160 short term stalls eXlk vatetpa~K r Freight elevator .r Down from G2 o'~teCm sr rr11 ~ rr rrr rs rr As s ■ evov\ 9~ ycramp exltIef 0,0 c ,n i l { rl ~r pedestrian exit to lower retail 1 retail delivery spy e pedestrian exit to lower retail G3 level - flow diagram LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership ~ ~ 1~ - ~VIIONaw VR477 page 7 L~ pedestrian exit to lower retail residences / hotel valet operations public parking high bay service and delivery 4240 Project Plan Submittal level G4 -571 public parking stalls G4 level - flow diagram The Open Hillwood Partnership V;Z.4~77 page 8 4240 Project Plan Submittal level G5 -665 public parking stalls e~tr t Lwes r a r • exit est exit from G6 ramp to ° r'~ Gro r • entN to G6 r .y O residences / hotel valet operations public parking high bay service and delivery G5 level - flow diagram LionsHead Parking Structure Redevelopment The Open ( Hillwood Partnership Z);z4;77 page 9 4240 Project Plan Submittal level G6 -369 public parking stalls a to am . r from G6 level - flow diagram The Open I HiIIwood Partnership midences I hotel valet operations page 10 4240 Project Plan Submittal VALETRAMPZ4 a a o 0 WPURCHASING/ RECEIVING 1-71 LL V - TI SERV K r 4 L DOCK Docx L I ~ a rn t ' LL 1 SKIER IL SHORT TERM EMIT y 7►-~ y SKIER ENTRY _ _ _ SHOITTTERM ENTRY TOWN OFVAIL ' _ - CONFERENCE 1EL-hs4' - - -i _ -------Rr fCO AUS/HO7Fl SHUTiIE -"a_ RCP OFF CAFE TRANSITSTAT10N , W-SPA 4.M ST EL-3,s4' RETAIL Lo IY .c.." WB-65 truck at entry VALET RAMP- I o a a 0 W-PURCHASING/ RECEIVING 1 I r- Ti 11`U'II L L TI SfAY TRUCK ~ Lr L DOCK 4 O y SKIER A, SHORT E- \ TEAM DIR y y SKIER ENTRY y \y SHORT TERM ENTRY - c y w-sPA RETAIL WIRY - - a TOWN OF VAIL CONFERENCE fi S.F. EL-hs4' - - - -1 ROPOFF nuiiu - - CAR TRANSIT STATION , 4.M SF. EL•RFS4' WB-65 truck at second bay loading dock - truck maneuvering _ w 4 ~a arr The Open I Hillwood Partnership DR477 page 11 W-PURCHASING/ RECEIVING VALET RAMPS T o a 0 0 -n -L TI SERVICE TRUCK L DOCK s' TOWN OF MAIL J CONFERENCE 16." S F- i El•hs4' 4~J 0 Ya Jll~- y . SKIER &SHORT TEAM EMIT E- \ y y ? y % F WS RE7AIL W-PURCHASING/ RECEIVING CAFE TRANSIT STATION , M.SA S.F. EL•hs4' P WB-40 truck at first bay VALET RAMP-) L3 a a U 4 ~ II a y SKIER&SHORT TEAM EMIT F- \ y y y TO.OFVAIL s ' - J CONFERENCE FER i EL-SIKH CAFE TRANSIT STATION , 4.sosSF. I ~~pj~•.Q] EL-8111 I\ 1 WB-65 truck at fourth bay 4240 Project Plan Submittal MEMORANDUM LEVEL OF SERVICE APPROACH TO PARKING DESIGN WALKER MEMORANDUM WALKER LEVEL OF SERVICE APPROACH TO PARKING DESIGN PAGE 1 PAGE 2 5350 S. Roslyn Street, Suite 220 DATE: May 19, 2008 Greenwood Village, CO 80111 To Louis Bieker AIA V i 694 303 6622 The goal for the Vail Lionshead project, with a large population of skier parking in the winter and visitor : , . o ce: . Fax: 303.694.6667 and shopper parking in the summer, should be LOS B. Understanding the desire of our client to provide COMPANY: 4240 Architecture Inc www.walkerparking.com a higher than average level of service, we strived for a design closer to LOS B+ or A% We have ADDRESS: 3003 Lorimer Street achieved this for most of the design criteria and exceeded it for some key elements, like the flow capacity CITY/STATE: Denver, CO 80205 of the system or the speed with which people are able to enter and exit the facility. Let's review the CC: Benjamin Gray - 4240 Architecture individual components. HARD COPY TO FOLLOW: Yes Parking stalls in the public areas are typically 9'-0" wide by 18'-0" deep, and the two-way drive aisles FROM: Larry W. Hofmockel are 24'-0" wide. All stalls are "full size"; there are no "compact only" parking stalls. This equates to an PROJECT NAME: Vail Lionshead Redevelopment overall parking module of 60'-0". WPC's LOS A is 61'-6", and LOS B is 59'-9", so this design is about an LOS B+ for parking geometry. PROJECT NUMBER: 23.7076.00 SUBJECT: Level of Service Design The following memo addresses recent questions raised about the overall level of service provided by our proposed design of the parking areas associated with the Vail Lionshead Redevelopment project. In 1989 Walker Parking Consultants (WPC) pioneered an approach to parking design termed the "Level of Service" (LOS) approach. Prior to this time parking designers used a number of "rules of thumb" for various elements of functional design. The LOS approach recognizes that different types of users (employees, visitors, patients, shoppers, residents, etc.) have varying needs related to their parking experience, and a more customized approach to parking design better serves the needs of an owner's specific clientele at an appropriate cost to the owner. Along the some lines as a traffic engineer's approach to roadway and intersection design, WPC developed four levels of service (LOS A to D, high to low) for a host of key design parameters essential to good parking planning. LOS B generally applies to facilities used by infrequent porkers unfamiliar with the particular venue they're attending (visitors, patients, shoppers, etc.) and where parking spaces turn over multiple times throughout the day (short-term parking). LOS C applies where people frequent the some facility on a regular basis (employees, residents, etc.) and where spaces may be occupied by the some vehicle all day long (long-term parking). LOS A might be considered by a few owners wanting to provide a very high level of service for their clientele, such as casinos, theme parks, high end condos, etc. LOS D is generally not recommended, but is sometimes used by developers needing to achieve a high parking count at a low cost or by an owner whose property just is not of a size to allow more comfortable parking design. LOS design parameters include such things as stall width, clear height, ramp slope, walking distances, lighting levels and a host of other criteria. Each of these can individually be categorized into LOS A, B, C or D. While the owner and parking designer's overall goal will be a certain level of service, it is rare that any facility will or can achieve the same LOS for each design parameter. For example, an airport may provide an LOS A or B design for almost all criteria, but it may not be economically feasible to provide a large enough toll plaza with enough staffed exit lanes to limit the wait time to an LOS A or B level. M:\21014 • Vail Lionshead Park ing\Received\WaIkerPorking\20080521 \MEM051908-Vail Lionshead LOS Approach.doc parking report By using the express ramp concept to circulate between parking floors, all parking stalls are on "flat" (except for gentle slopes for drainage) floors. LOS A is 90% on the flat, so this project is LOS A+ from that perspective. The number of spaces per floor in an express ramp design is an indication of the time it will take to search for and find an available parking space. Parking Level G4 contains about 600 stalls, Level G5 about 700 and level G6 about 400. LOS B is 500 stalls for 90 degree parking, and LOS C is 750, so this project is about an LOS B- or C+ on the two larger floors and an LOS B+ on Level G6. Long uninterrupted rows of parking are a more efficient use of space, but they tend to increase the time to search for available parking and also the time to circulate back to the exit. Parking rows longer than 400' should contain a "crossover" to be able to "short circuit" the drive between parking rows. The north/south parking rows in our design are typically about 270' long on Levels G4 and G5. LOS A is 250', and LOS B is 300', so we are at LOS B+. The two east/west parking rows on level G6 are nearly 500' long, and we should consider adding a crossover at this level. The floor-to-floor height between parking levels is 11'-0". Depending on the final structural design, that should result in an internal clear height of about 8'-6" to 9'-0". A minimum of 8'-2" is required to accommodate accessible van parking. LOS A clear height is 9'-0", and LOS B is 8'-4". Our design is again in the LOS B+ range. The slope of the express ramps from the street to the first parking level and between the parking levels is in the range of 14%. LOS C is 13.3 a/o-, and LOS D is 16%, so this design is about LOS C- for ramp slope. The ramp is a little steeper than we would prefer, be we are limited by the length of the garage available to achieve the straight cascading ramp concept that is desired to most efficiently move the large volume of vehicles expected. To achieve an LOS B ramp slope of 10.67% would require changing to a "stacked" system of express ramps where ramps between levels are stacked over top of each other and drivers must circulate each floor to get back to the next ramp up or down. Another alternative could be a spiral helix concept similar to what is seen at some large airport parking structures. The straight cascading express ramp is superior to these other alternatives in terms of quickly moving vehicles in and out, and it's my opinion that an LOS C- slope is a minor inconvenience to achieve this superior design. M:\21014 • Vail Lionshead Park ing\Received\WolkerParking\20080521 \MEM051908-Vail Lionshead LOS Approach.doc Z);Z+77 ;Va7&r y spz ~ / zm&lf & no-" tt': 4240 Project Plan Submittal page 12 LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership t1111 MEMORANDUM WALKER LEVEL OF SERVICE APPROACH TO PARKING DESIGN PAGE 3 The current design incorporates two separate express ramps, one from the east and one from the west. Both ramps have one inbound and one outbound lane. The flow capacity of an unobstructed straight express ramp is 1,850 vehicles per hour (vph). The total public parking count is about 1,800 stalls on levels G3 (short-term) and G4/5/6 (long-term). The Kimley-Horn traffic study projected the highest volume condition as 775 vehicles entering from the east in the peak hour. Clearly our express ramp concept can easily accommodate this volume. The flow capacity of the primary ramp system is LOS A. When partial level G6 was recently added to increase the total parking stall count, we did have to use a stacked ramp concept between G5 and G6 because there was not enough space to continue the cascading ramp. We have provided as short a circuit as possible to get off on Level G5 and circulate around to the express ramp down to G6. This will increase the travel time slightly for patrons who park on G6, however G6 likely will be the last parking stalls to get used and only when the garage is at or near full capacity. People who park on Level G6 probably have an LOS B experience in terms of their travel time in their vehicle, where people parked on G4 or G5 have an LOS A experience. Our design uses a pay-on-foot operation where the long-term public porkers will pull a ticket at one of the entrance lanes before proceeding to park on levels G4/5/6. After a day of skiing or shopping and prior to returning to their car, patrons pay for their parking at one of several pay stations conveniently located throughout the development. Then the validated ticket is used at one of the exit lanes to open the exit gate and let you onto the express ramp out. Enough entrance and exit lanes are provided at the various levels such that the queue of vehicles waiting in line at peak times does not exceed six vehicles, and the average queue throughout the day is two vehicles or less. Ticket verifying machines at the exits have a processing rate of 360 vph or six per minute. The longest anyone should have to wait in line to process through an exit gate and get onto the express ramp is a minute or two. The entering and exiting process is an LOS A as currently planned. There are several banks of elevators spaced throughout the parking floors. A walking distance of 300' from anywhere in the garage to an elevator equates to an LOS A, and 600' is LOS B. I estimate about 90% of the parking area is within 300' of an elevator bank, and 100% is within 350'. 1 believe this criterion qualifies as LOS A% The final design parameter presented here is the lighting level inside the garage. For safety and security reasons and for the overall comfort level of the patrons, we plan to provide LOS A lighting in the typical parking areas, which is 4 foot-candles minimum illuminance and 10 foot-candles average illuminance, with higher levels used at other key locations like entry/exits, pedestrian towers, pedestrian cross walks and the like. So these are the primary design criteria, and as one can see, most fall into the range of LOS A to LOS B+. The two exceptions are the number of parking stalls on Level G5 and the express ramp slope, both of which are in the LOS C range. None of the design parameters are LOS D. To sum it all up and give the parking an overall rating, it's my opinion that this project overall rates LOS B+. M:\21014 • Vail lionshead Parking\Received\WalkerParking\20080521 \MEM051908-Vail lionshead LOS Approach.doc parking report MEMORANDUM WALKER TRUCK DOCK REVIEW PAGE 1 5350 S. Roslyn Street, Suite 220 DATE: May 21, 2008 Greenwood Village, CO 80111 TO: Louis Bieker, AIA Voice: 303.694.6622 COMPANY: 4240 Architecture Inc : 303 667 Fax www.walkerpararkinking.com ADDRESS: 3003 Larimer Street CITY/STATE: Denver, CO 80205 CC: Benjamin Gray - 4240 Architecture HARD COPY TO FOLLOW: Yes FROM: Larry W. Hofmockel PROJECT NAME: Vail lionshead Redevelopment PROJECT NUMBER: 23.7076.00 SUBJECT: Truck Dock Concept Design Per your request, we reviewed the concept level plan prepared by 4240 Architecture of the truck dock area located north of the west vehicular entry/exit portal on level G2. While we do not consider ourselves truck dock experts, and we recommend you eventually have this reviewed by another consultant more experienced in this field, Walker Parking Consultants (WPC) does have a commercial software package called "AutoTurn" by Transoft Solutions that contains the ability to check turning maneuvers for all kinds of vehicles, including various sizes of trucks. We emailed to Ben on May 5 some visual representations of truck maneuvers in and out of the proposed loading dock area. A hard copy of those is attached. There are six truck bays proposed in the current dock configuration. For purposes of this memo, I will label those 1 to 6, south to north. It appears that a semi tractor trailer as large as a WB65 (73.5' length) should be able to maneuver in and out of Bay 2 if there is a smaller truck in Bay 1 and a large truck in Bay 3. A WB65 should be able to maneuver in and out of Bays 3, 4 and 5 even if there are large trucks in the adjacent bays. A WB65 should be able to maneuver in and out of Bay 6 if there is a small truck in Bay 5. Bay 1 will be limited to smaller trucks, WB40 (45.5' length) or shorter, due to the lack of maneuvering room next to the automobile exit ramp. We did identify a minor issue with the truck entry ramp from the west. It appears as currently laid out, the curve in the ramp is too tight and too narrow to allow a WB65 truck. However, it appears that a slight adjustment in the layout of the auto and truck ramps at the west portal can be made to allow more maneuvering room. M:\21014 -Vail lionshead Pork ing\Received\WalkerParking\20080521 \MEM052108-Vail Lionshead Truck Maneuvers.doc V R.9#77 13 L R1-I 4240 rroject Plan Submittal LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership page ~ Kimley-Horn Mr. Greg Hall, Town of Vail, May 5, 2003, Page 2 ~ Kimley-Horn and Associates, Inc. and Associates, Inc. Technical Memorandum To: Greg Hall, P.E. Town of Vail From: Curtis Rowe, P.E., PTOE Kimley-Horn and Associates, Inc. Date: May 5, 2008 Subject: Lionshead Parking Structure Redevelopment Project Porte Cochere Traffic Analysis The Lionshead Parking Structure Redevelopment Project is a proposed mixed- use development located along the south side of the South Frontage Road at the existing Lionshead Parking Structure site in Vail, Colorado. The redevelopment project would include replacement of the existing parking structure with a new parking structure below grade and new development above. The redevelopment project is proposed to include two (2) hotels with 120 rooms each, 146 units of condominiums, approximately 75,000 square feet of retail space, and a 42,000 square foot community center. In addition, public skier drop-off, buses, and delivery vehicles would be accommodated below grade as part of the parking structure improvements. The purpose of this technical memorandum is to evaluate the adequacy of the proposed porte cochere for the Lionshead Parking Structure Redevelopment Project to determine its ability to accommodate arriving/departing vehicles. The porte-cochere will be used by the hotel and condominium guests for registration/check-in and check-out. Peak hour of the generator trip generation calculations were conducted for these two uses to determine the peak traffic volume anticipated at the porte-cochere during the peak hour. Based on the ITE Trip Generation equations (calculations attached), the hotel and condominium uses are anticipated to generate 218 trips during the peak hour of the generator, in which 120 vehicles would be entering and 98 exiting. Since there will be effectively two porte-cochere operations occurring, the entering traffic was divided equally for each hotel porte-cochere. Studies and observations were conducted at porte cocheres within Las Vegas, Nevada at resort hotel and timeshare condominiums. It was found that the average check-in/registration time was 2 minutes and 40 seconds at these port. cochere analysis VR477 facilities. For purposes of this evaluation, average wait times within the registration/check-in area was assumed to be three minutes. Based on an average registration/check-in time of 3 minutes, the 60 vehicles per hour entering each porte cochere were found to require 75 feet of vehicles storage (3 passenger cars). Therefore, the proposed approximate 100 feet of storage for each hotel porte cochere is believed to be adequate to serve the hotel and condominium guest demand. In fact, as long as the registration/check-in time average is less than 4 minutes, the amount of storage proposed on site is expected to be adequate. This analysis resulted in the following recommendations: Since separate porte cochere operations are proposed for each hotel, it is important that the areas be well designated and signed for the arriving guests. Average wait times for vehicles at registration/check-in should be minimized with a goal of providing service within an average of 3 minutes. As identified, an average wait time of less than 4 minutes is anticipated to be sufficient service for adequate operations of the porte cochere. The access in from the eastbound left turn along the South Frontage Road and the left turn out should be configured so that they are in close proximity to each other to facilitate improved operations and vehicle movements at the proposed access along the South Frontage Road. The proposed porte cochere configuration is shown on the attached exhibit. Pai&q Srh ~ / Zaa&,ej~ & Z)&~zeV ~7 - &A&4n 5 page 14 LionsHead Parking Structure Redevelopment The Open Hillwood Partnership 424 Project Plan Submittal M / 1 and Associates, Inc. Project _ Subject _ Designed b3 Checked by Lionshead Peak Hour king Structure Redevelopment Porte Cochere Generator for Residential Condominiu CDR Sheet No. 1 of 1 TRIP GENERATION MANUAL TECHNIQUES ITE Trip Generation Manual 7th Edition, Average Rate Equations Land Use Code - Residential Condominium/Townhouse (230) Independant Variable - Dwelling Units (X) X = 146 T = Average Vehicle Trip Ends Peak Hour of Generator, Weekday PM Peak (page 371) Directional Distribution: 64% ent. 36% exit. T = 0.52' X T = 76 Average Vehicle Trip Ends T = 0.52 ` 146.0 49 entering 27 exiting 49 + 27 = 76 Land Use Code - Resort Hotel (330) Independant Variable - Occupied Rooms (X) X = 240 T = Average Vehicle Trip Ends Peak Hour of Generator, Weekday PM Peak (page 371) Directional Distribution: 50% ent. 50% exit. T = 0.59 ` X T = 142 Average Vehicle Trip Ends T = 0.59' 146.0 71 entering 71 exiting 71 + 71 = 142 Total Peak Hour of Generator Trip Generation Through Porte Cochere In Out Total 146 Condominiums 49 27 76 240 Hotel Rooms 71 71 142 Total 120 98 218 porte cochere analysis LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership Z);ZA?;77 page 15 4240 .-roject Plan Submittal P,q,.49r (04PIZOP08 &40~ 6 The Open Hospitality Partners & Hillwood Capital [Open I Hillwood] Partnership view from public square IF LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership DR,477 page 1 ? - &A&rm 06 4240 -'roject Plan Submittal / / LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership VRW77 page 2 Ca .10 ?gat - &O&t 06 - - 4240 Project Plan Submittal visitors and employees coming to lionshead by regional bus will arrive at a defined portal instead of the current "back door" on Lionshead Place" Lionshead Redevelopment Master Plan 4.5.2.1 - - - - - - - - - ' /1 ~eco-bus shuttle drop-off -I F-71 L_ C' rill a, U 0 M W stair/elevator servicing parking below RETAIL - ~1 To Mountain and Retail user flow / plan adjacencies LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership Z);ZO?7? page 3 sµ~ elevator servicing porte cochere level to G3 (short-term parking RETAIL ut Reteffl and Dobson Arena PEDESTRIAN MOVEMENT 06 4240 !project Plan Subrnittal M circulation to/from transit station LionsHead Parking Structure Pedeveloprnenr The Open Hillwood Partnership V;Z.4707 page 4 a ~ 4 d 1- PORTE ~pp,~~ ♦ COcHERE A I A91 CONFERENCE ?uada &x~ - &4#rm 06 4240 Project Plan Submittal sectional view / circulation core V;Z477 &14A~ od LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership page 5 1 y11~ 4240 Project Plan Submittal Feature wall to introduce natural daylight and texture to the lower levels of the parking garage I ossible feature wall elements feature wall LionSHead Parking Structure Ptedeveiopmen The Open I Hillwood Partnership Z);Z.477 page 6 06 4240 -'roject Plan Submittal !j -The Transit Station will be clean and simple, utilizing white subway the walls similar to traditional train and-- bus stations throughout Europe and the United States. -Natural light will penetrate through the storefront glazing in the Cafe and waiting area. -Ventilation systems will be designed to eliminate exhaust and fumes from the station. transit arrival Bus and ho tel van drop-o f f is in tegra ted into the below grade parking garage in order to alle via to vehicular traffic in the pedestrian oriented areas of Lionshead... "The congested and confused main Lionshead pedestrian portal is the most in need of corrective action... vehicular traffic, skier drop-off, local and regional shuttle vans, and service and delivery vehicles should be removed from this location" Lionshead Redevelopment Master Plan 4.6.3.3 LionsHead Parking Structure Redevelopment The Open I Hillwood Partnership r);Zj?;7? page 7 - 06 - ' 4240 Project Plan Submittal Glass block floor above to allow light to penetrate Transit Station..: ib~ I L " r L view to eco-bus drop-off beyond LionsHead Parking Structure Redevelopment The Open Hillwood Partnership V;Z4577 page 8 ti ?uuja &,arm - &40t,Qti 06 LL.Kt, ` M %v,! k" ul 4240 Project Plan Submittal LionsHead Parking Structure Redevelopment The Open Hillwood Partnership f);ZW?;7? page 9 4240 &WZm 06 Project Plan Submittal view to main plaza and mountain beyond