Loading...
HomeMy WebLinkAboutE09-0173NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MnO Vv Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit E09-0173 ACOM Project PRJ09-0419 Job Address: 174 E GORE CREEK DR VAIL Status ISSUED Location.....: POOL, LODGE AT VAIL Applied. . : 09/14/2009 Parcel No...: 210108281001 Issued . 09/18/2009 Expires. 03/17/2010 OWNER LODGE PROPERTIES INC 09/14/2009 Phone: 81657 IN CARE OF C/O FIXED ASSETS DEPT 390 INTERLOCKEN CRESCENT STE 1000 BROOMFIELD CO 80021 APPLICANT TOLIN MECHANICAL SYSTEMS COM 09/14/2009 Phone: (303) 455-2825 12005 E. 45TH AVENUE DENVER COLORADO 80239 License: 412-E CONTRACTOR TOLIN MECHANICAL SYSTEMS COM 09/14/2009 Phone: (303) 455-2825 12005 E. 45TH AVENUE DENVER COLORADO 80239 License: 412-E Desciption: COMMON ELEMENT: INSTALL BREAKER PANEL, CIRCUITS TO POWER NEW BOILERS AND EQUIPMENT IN POOL MECHANICAL ROOM Valuation: $5,000.00 Square feet: 0 FEE SUMMARY .***.,**,*.*«*...****„*,..**..,***...**.<.***«,..*«*.w.**,..*«**.. Electrical Permit Fee--------- > $109.25 Total Calculated Fees--> $113.25 Investigation Fee--------------> $0.00 Additional Fees > $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee------------------- > $0.00 TOTAL PERMIT FEE---> $113.25 Total Calculated Fees > $113.25 Payments-----------------> $113.25 BALANCE DUE---------- > $0 00 . APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 09/16/2009 Martin Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM _ n re dfigWne ntractor ate elec_prm_041 TOWN OF VAIL COLORADO , Statement Statement Number: R090001252 Amount: $113.25 09/18/200912:00 PM Payment Method:Credit Crd Init: SAB Notation: MC-MIKE CLEMENT Permit No: E09-0173 Type: ELECTRICAL PERMIT Parcel No: 2101-082-8100-1 Site Address: 174 E GORE CREEK DR VAIL Location: POOL, LODGE AT VAIL Total Fees: $113.25 This Payment: $113.25 Total ALL Pmts: $113.25 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts EP 00100003111100 ELECTRICAL PERMIT FEES 109 25 WC 00100003112800 WILL CALL INSPECTION FEE . 4.00 ti Department, of Community Development 75 South Frontage Road t. Vail,Colorado:.81~57'' q s :Tel 970 479-212 ti* r, .w Fax 570 479; 452 Web- www.vailgov"torr).y Development Review Cogrdinatof, ELECTRICAL PERMIT Project Street Address: (Number) (Street) (Suite Building/Complex Name: a~ 424 1 Contractor Informs on: Company: / ] Q,,- /7,,_2 i'l (~'q Office Use: Q~ Project ( o Building Permit r l V ~ - o C-0 C Ele trical Permit O I aj C Lot Block # 5 Subdivision:kWi Vi( I Company Address::2Y,-' '2 Detailed Description of Work- City: State: Zip: 3 1 Contact Name: j#///L0_ m~ Contact Phone: E-Mail O~ 711 ~ use additional sheet if ecessary; 6~~ t Town of Vail Contractor Registration No.: ~ Work Class. i X New ( ) Addition ( ) Remodel ) Repair ( ) Other ( Arp ) E Contract Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial Property Information Restaurant( ) Other( ) Parcel (For parcel contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Date Received: Tenant Name: Owner Name: b'- ? COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUA- TION OF WORK (Labor & Material) Amount of SQ Ft.: Electrical D ~ JL Com- rtzg GxPr"ed - 1. ~nl SEP 09 2009 w- NOTE: THIS PERMIT MUST BE POSTED ON JOBS/ TE A T MWNO VVAII Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ACOM Job Address: 174 E GORE CREEK DR VAIL Location.....: POOL, LODGE AT VAIL Parcel No...: 210108281001 OWNER LODGE PROPERTIES INC 09/02/2009 Phone: 81657 IN CARE OF C/O FIXED ASSETS DEPT 390 INTERLOCKEN CRESCENT STE 1000 BROOMFIELD CO 80021 APPLICANT TOLIN MECHANICAL SYSTEMS CO. 09/02/2009 Phone: 303-455-2825 ATTN:SHE'JACKSON 12005 E. 45TH AVE. DENVER CO 80239 License: 221-M CONTRACTOR TOLIN MECHANICAL SYSTEMS CO. 09/02/2009 Phone: 303-455-2825 ATTN:SHE'JACKSON 12005 E. 45TH AVE. DENVER CO 80239 License: 221-M Desciption: COMMON ELEMENT: REPLACE BOILER FOR SWIMMING POOL Valuation: $170,000.00 ALL TIMES Permit M09-0164 Project PRJ09-0419 Status . . . : ISSUED Applied 09/02/2009 Issued. 09/09/2009 Expires . 03/08/2010 wwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwewwwwFEE SUMMARY***www*www****w******w******wwww*wwwww*wwwwwwwwwwwww*w*www**wwwwwwwwwwwwwwwwwwwwwwwww Mechanical Permit Fee---> $3,400.00 Will Call > $4.00 Total Calculated Fees $7,454.00 Plan Check > $850.00 Use Tax Fee------ > $3,200.00 Additional Fees-----------> $0.00 Investigation-----------------> $0.00 TOTAL PERMIT FEE---> $7,454.00 Total Calculated Fees--> $7,454.00 Payments-----------------> $7,454.00 BALANCE DUE--------- > $0.00 w+wwwwwwwwwwwwwwwwwwwwwwewwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwewwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww*wwwwww*wwwwwww*wwwwwwww*w***wwwww*x*wwww**w*ww*ww**wwwwwwwwwwwwwwwwwwwwwwwwwwwww Item: 05100 BUILDING DEPARTMENT APPROVALS 09/04/2009 cg Action: AP wwwwwwwwwwwwwwwxwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwxwwwwwwwwwwwwwwwwwwwrwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwwww►ewwwweewwwwwwww**ww*www****www*ww**wwwww*www*wwwww*wwwxwwwwwwwwwww CONDITION OF APPROVAL Cond:12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED mechcanical_permit_041908 MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM -ADM ate mechcan ical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090001169 Amount: $7,454.00 09/09/200903:51 PM Payment Method: Check Init: SAB Notation: 53876 TOLIN MECHANICAL Permit No: M09-0164 Type: MECHANICAL PERMIT Parcel No: 2101-082-8100-1 Site Address: 174 E GORE CREEK DR VAIL Location: POOL, LODGE AT VAIL Total Fees: $7,454.00 This Payment: $7,454.00 Total ALL Pmts: $7,454.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts MP 00100003111100 MECHANICAL PERMIT FEES 3,400.00 PF 00100003112300 PLAN CHECK FEES 850.00 UT 11000003106000 USE TAX 4°s 3,200.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ~Y 1 1.- Department of Community Development. 75 South Frontage Road Vail,;Coloradox.a-t47,' x- ."Tel:', 970-479 2'i FaX 9704~~ X452 Web vvww vailgov~W, ~ Development. Review r✓oordi'nbto xx MECHANICAL PERMIT Boiler/Furnace Applications MUST include: Fireplace Applications MUST include: ❑ Mechanical Room Layout/Plan with Dimensions ❑ Equipment Cut Sheets for Fireplaces/Log Sets ❑ Combustion Air Duct Size and Location (Manufacturer's info showing make, model & approval listing) ❑ Flue or Vent Size ❑ Gas Piping Plan (if applicable) ❑ Heat Loss Calculations* ❑ Equipment Cut Sheets for Boiler/Furnace * Not required for same size (BTU) boiler replacement with no system changes, or snow melt Project Street Ad ress: (Number) (Street) VA (Suite Building/Complex Name: / e _ ark I I Contractor Information: Company: Company Address: V % ,__r/'/.YW ft on r City: rr,_/State:Zi Contact Name: _ ~KlNS/ /~/iMl/ Contact Phone: hOh - 1l&-167 E-Mail Town of Vail Contractor Rdgistration No. Property Info tion Parcel Z10 0 (For parcel contact Eagle Coun visit www.eaglecounty.us/patie) Tenant Name: -bid. at 970-328-8640 or (Commercial Properties) Owner Name: Complete Valuation for Mechanical Permit: Mechanical $ X70. DOD 1-.----- Office Use: Project FW-J 0q-0 q-'q / Building Permit M apical Permit Vi ~a Lot Block #✓L.- Subdivision: t 1 Detailed Description of Work: a ne r Le n l s 1 i I (use additional sheet if necessary) 4 Gas Piping Included Gas Piping by Others ❑ Wood to Gas Fireplace Conversion Boiler Location: s Interior I-) Exterior ( ) Other ( ) Number of Existing Fireplaces: Gas Appliances Gas Logs Wood/Pellet Number of Proposed Fireplaces: Gas Appliances Gas Logs Wood/Pellet Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial W), Restaurant( ) Othe n _ Date Received: AUG 3 1 2009 TOWN OF VAIL V~~ N tO tUALkUJAY I 1~~ 8 35 2.. I tD POOL SNOlUM1=Lt Afi~E~45. SNOtUM~Lt A12~A. 3 MANI~OLpS UJIt~{ 4 LOOPS, I MANIFOLD lUI1'N ~ 5i8" tI~BINC~. 1 MANIFOLp Wlt+~ ~ LOOPS, viz" tU~INC~. 5 LOOPS, ~~e" tUBINC~. v~~ ~ ~ ~ I ,t}2 z I A AGGESSORIES I I ~I I~ z ? ~ ~ ~ ~ ~ 2 - ~a10~ GLYGOLE KIT ~ -NOT u91=DAME RATED ~ ~ 1 z z ~ ~ 3 - ASME RATED lN-STAMP) ~ -NOT USED ~ lr iJ ~ -1 I_ ~Q.. SYM, tYPE ~.L. INPUt ALt OUtPUt DUEL DELTA ELEC, MANUI=AGtURIrR A~IJE AGGESSORIEB V I~ zl 1~3=RYESJ MB+ MBN t ~ ~ M4P~L ~ O ~Iu ilk za ~z * ~-`~X w -I I- ALI~MINI~M N,4`C. ~ 12/1 ~'K MAGN I, ~ <C z c~l ~ I~ B 8-1 ~ 2 G©ND~N5INC~ 1,~5~1 ~~13,9 CxAS 3~ ~ ~ S A G-1~~Q~ 91iQ ~ ~ ~ ~ XI I X !u lU U11Z ZIU.C w _ u~ MY-1 M ~ A3 A AI GLOS>=L1' SPAGI=D t~~5 NX-1 ~ P AS-1 ~~t A ~ ~ 1-IU..JS z~~2,~ ~ 0 ~ o c SYM. GAPAGITY' SIDE I (N4t) SIDS 2 (GOLD) MANU~AGtUR1=R ~ ~ ~ ~ ~ l5~ 3.. 2i,~ ISERYEB) IMBN) 1`LUID EWt LWt FLOW P.D. FLUID EWT Luri' I;LOW P.D. MOp1=L NUMBER ~I" ~ - NUR (GPM) l~T) l°I=) (GPM) (~T) ~ ~ ~ ~ ~ 1=ROt"1 P00~. 1 I ~ s 2~~2~~ 2iz~~ I- I lP (uXvl) 1,235 ~'O~° 1~Q~ 11 D 92 FOOL 8~ 11~ 83 3.3 CxE,4 i ~ ~ PooL PCx ~U,4t5R MPN10X20L-~O12% MP~'~ ~ NO' NOTE; ELEGTRONIG GNLORINE GENERATORS THAT uT1LIZE SALT (NaGU ARE N07 SUITA6LE I'OR IISE WITH TNfB NEAT EXGNANGER Seal ~ z 11= SUGN A SYSTEM IS TO BE USED, IMMEDIATELY GONTAGT ENGINEER 1=0R RE-SPEGI~IGATION OF NEAT EXGNANGER ~ w~ N l'~ ~ ~ Z iL ~ ~ 8-1 ~-2 0~- - ~z 4, ~ ~ y 59 ~ ~ 59 ~ ~ S ~ ~ ~Q z +451= BIB ~ ~ ltd' ~ ~ P.I z u~ U~ i }-ai P / _ P _ __I S~~' BOI~~RS UN G NSAI` DU N A 18" tALJ_ S~'AND, ROI~TE BOf~.~R OND~ E 7NR C~ l,l~ I A I© A 0 ISGNA N~ RA1. ~ N B .SIN PRIaR 7 D RC~~ NQ SGA~E IN~0I=LOOK DRAIN WI~'N AIR CHAP. 1 r 12 ~ Y~N1' ~'O ROOI~. MfNAl' UJI~'N 1;ASNSEAL DauaL~ U1A~L Y~Nt ~©R ~R ~ ~ASNS A AIN GA . GA~'~C~OR~' i11 AP1~LIANG~. AL29-4G ~ L R p ~ St IN S ~ fNN~R ~UALL, 3~1 A ~~S OI~tER IUALL. 12"'~ 12°~ VEND' i" EXISTINCx 32x1 O~1VE , R A OXIMA~' 1`" ~~°ro PF'R 12"~ 12"~ GA FREE AREA. ~ ~ _ _ I~~ ~ - - s ~ ~ ~ ~ASNS A AIN 1=1~' I t ~ ~ DR NCB. RO1~ ~ 5F AIN ~`4 A N Ut A I AtION ~ DR E R ~ x TO1 _ _ i BASIN PRIOR 7'O DISGI~ARC~E ! ! I I i INtO 1~ DO AIN. (5 M1.ID/A) ~ R DR EE 1 I I I ~ ~ANS~AL 8 ~ Bl~AS~t C~A~'E 1 1 I I ASSEMBLE' (PRO~~GN I I I I S~'S~'EMS). 1 ! 1 I 1 I I I I I~ I I~ 1 1 I ~I`L I ~I`L Q, _ y y ~ d ~ ~ y w 1Gl U„J Q B 1 B-2 8 4 TO ~ ~ REDUCER 1=0R - , ~ 15~ 0~~ BOILER CONN~GtION ~T~'p.) ml0 B SEA' BOILERS ON CD 18" BALL SCAN , D E NO SCALE ti t5~1 N f P~ (O~ NO1  u %J Project No. Scale. z 4 51 5YM. C-4PM TDB{ Hf=1 VOLT/PH MANUFACTURER DE5CRIPTION } lY z 9026.00 NO 5CALE 6 o~ 4 MODEL NO. q Drawn 5y: Checked By: ~ -q uu F, F-142 53 12 1/2 115/1 GRUNDF05 5OILI=R PuMPB JWC JDR W z 0 f OPl (OPTION UF5 40-80/4 2 Q z ~ P POOL HEAT EXCHANGER ml 0 ~ 0- CxRl~ND1=05 P-4 92 2ro 1-1/2 208/3 PUMP 2 u w 0 f OP7 (OPTION) UP5 50-1&012 • } L1 U zz -4(g N N l~ ati n 1$. All equipment shown on this plan is new, except where noted. General Mechanical S ec c a s Sequence of C}perations ~ ~ ~ 19. All removed i in , ductwork, e ui ment, etc. are to be dis ased of by contractor unless noted General ppg q p p l. B-1 & B-2 Boilers 111 ~ otherwise. a. Boilers shall be controlled by Heat-Timer Boiler Contralsthat that will stage and modulate the boilers. ~ ~ ~ 1. Immediately notify the engineer of any discrepancies. Insulation Boilers shall be stated for equal run times. Boilers shall have a 5 minute minimum off time to prevent r-- shortcycling, Coordinate additional control functionality with owner. ~ ~ 6? 2, Da not scale drawings. Verify dimensions in field prior to commencement of work. , 20, Insulate all new heating water with U.L. approved, white, all service, glass fiber, snap-an, l thick an b. Bailers shall be staged in "parallel modulation"' arrangement and modulate to maintain HWS setpoint at ~ a aquastat Al of 144°F (adj.} when there is a call for heat. ~ mains and ~/Z" thick an runouts, pipe insulation. Insulate fittings with glass fiber blanket insulation and 3. It is the intent of these drawings and specifications to establish a standard of quality. The engineer c. P-1 and/or P-2 pumps shall run whenever associated boiler is firing. ~ ~ z premolded PVC covers. reserves the right to take exceptions to approve methods and materials net reflected herein. 2. P-3 Snowmelt Pump ~ ~ ~ uzi 21. Insulation for all types of piping shall be carried fu11 size through pipe hangers. 4. Failure to artier, or release order, for materials and/or equipment will net be accepted as a reason to a. Snowmelo system shall run continuously during open pool hours while the outside air temperature is ~ ~ ~ ~ substitute alternate materials, equipment, or installation methods. below 3$ F (adj.} and shall run based on demand while pool is closed. Provide Heat Timer SMC ~ ~ ~ ~ ~ Pi in Snowmelt Controller or equivalent, time-clock and moisture/ temperature sensor (location to be ~ ~ ~ 5. Work sha11 be performed in a workmanlike manner to the satisfaction of the owner & the engineer. , determined based on field condifrons}. Bailers shall be enabled while Snowmelt system is running, , 22. Heating Water piping -For non-buried piping, type M copper, wrought capper fittings, and no lead soldex. Provide alternate rice for PBX Lubin with ax en diffusion barrier . All i e sizes on fans are p g~ Yg ) pP p b.Upon acall for snowmelting from time clock ormoisture/ temperature sensor, P-3 Snowmelt pump ~ ~ ~ ~ 6. Labor, materials, and equipment shall conform to the latest applicable editions of local, State of Colorado, for copper pipe. and National Caries and ordinances. If conflict between those publications exists, the mast stringent r uirement shall a 1 . . ~ pp y 23, Condensing Bailer Condensate shall be neutralized via a neutralization basin before discharge into i' buildin drama e s stem. Condensate i in shall be PVC ar other a roved material suitable far H 7. The drawin s show the intent of the mechanical s stems but da not show all details re aired. It is the g g y ppg pp p g Y q levels of 3. responsibility of the contractors to install complete & operable systems, which conform to the manufacturers' installations instructions & Indus standards. 24. Gas Piping -Schedule 40 black steel pipe, ISO lb. malleable iron screwed fittings on above ground i e welded fittin s with all i in coated and wra ed on buried i e, S~jstems shall be tested for ro era eratian. If tests show work is defective contractor shall make p p ~ g ppg pp p p J P p p corrections necessary at na cost to owner. 25. Gas Valves -Lubricated plug. valve 175 lb. W.O.G. iron screwed or flanged. . I i he c ntractors' and manufacturers'res onsibili to assure themselvesthatthe codeauthorities 9 t s t o p tY 26: Copper pipe Valves and Specialties: will approve any product to be installed on the pralect. Gate Valves: Bronze Glass 125 2001b. W.O.G. IO. Provide necessary trenching, backfill, excavation, supports, piping, i~sulatiaii, saw cutting and . ~ _ „ o Ball Valves: Bronze, Class 125, 2001b. W.O.G. patching, concrete/paving, etc., as requn~ed. Backfill trenches m 6 layers and to 90 /o compaction and Check Valves: Bronze, Class 125, 200 Ib. W.O.G. patch to match existing grade, BalancingValves: 125 psig w.p,for 250E service tight shut-off, Illinois dual- cur ose balancin r/shut-off val vc Hoffman Sarca are uivalent. 11. S stems shall be rafessionall labeled. Pi in shall be labeledwith color coded commercial ~7rade 1 p ~ q Y p y pg b la el indicaten i in service and flaw direction. Pum s and valves shall be labeled with engraved b s gpP g p e ~ 3„ 2'1. Grade and valve all heatmgwater prpm~ with f4 base end valves to permit drainage of the system. plastic or metal tags and a pumplvalve schedule shall be provided and mounted on the mecliamcal,room Vent alllaigh points in egiti~ment rooms as necessary with automatic aix vents piped to convenient drain. wall. Equipment shall be labeled with engraved plastic ar metal tags.. All highpoints iirsystem outside of equipment rooms with manual air vents as required to relieve air in the s stein. 12. Offset i in ductwork etc. as necess to accommodate structure, beams, columns, and existin y p p g~ s ~`Y g e iii meat. q p Gl col Solutions Shop Drawings o 0 2$. Fill heating water system with 50 /o propylene glyco11501o water solution. 13. Submit entire sho drawin submittal data at one time. Submittal to tae bound in three-rin binders, p g g Controls indexed in a neat and orderly manner. Partial submittals will not be accepted. Submittals shall . ent um s i in valves and bailers. , include, but net be limited to. equipm , p p , p p g, 29, See Sequence of Operation far additional control information. Remodel & Demolition - , clu e in the bid costs re aired to make work meet 14. Visit site prier to bid and verify the conditions. In d q e i tin con itions whether indicated or nat. xs g d , 'cal demolition re aired. Visit site rior to bid to determine extent of work involved. I5. Provide mecham q p materials as re aired to maintain and/or restage continui of service to existin Provide labor and q ty g s stems. y a r it that certain assum bans be mad 16. In as much as design for remodel and/or rehabilitation.. aqu es p e ca e some of these`assum Lions cannot be verified without regarding existing conditions and be us p . ~ f e buildin . The en ineer cannot assure the destroying otherwise adequate ar serviceable portzons o th g g 1 'n se ice herein cncom ass all contin envies. owner or the contractor that the professional Gansu ti g rv s p g t' ` im erative ontractorsbiddin this workmustmake Field caordmation dunng construe ion is p . C g e or unseen conditions, reasonable allowanc s f t 1 i tin i in e ui ment ductwork etc. 17. Field verify locations of all ex s gpp g, q p , ~ I c -_I i J 'P f f i Project No. 5ca le. Z 902ro.00 NO 6CALE o d p Drawn By: Checked By: Q z 1 N JWC JDR I-- W:!= zz UW0 m 1.1 *)q- d / SL 5 - 10 -14 -2009 Inspection Request Reporting Page 20 4:20 nm Vail C[) - Cifv of 1 Requested Inspect Date: Thursday, October 15, 2009 Inspection Area: SH Site Address: 174 E GORE CREEK DR VAIL POOL, LODGE AT VAIL A/P /D Information Activity: E09 -0173 Type: B -ELEC Sub Type: ACOM Status: ISSUED Const Type: Occ ancy: Use: Insp Area: SH Owner: LODGE PROPERTIES INF Phone: 81657 Contractor: TOLIN MECHANICAL SYSTEMS COMPANY Phone: (303) 455 -2825 Description: COMMON ELEMENT: INSTALL BREAKER PANEL, CIRCUITS TO POWER NEW BOILERS AND EQUIPMENT IN POOL MECHANICAL ROOM Requested Inspection(s) Item: 190 ELEC -Final Requestor: TOLIN MECHANICAL SYSTEMS COMPANY Assigned To: MDENNEY Action: Time Exp: S / Inspection History Item: 120 ELEC -Rough Item: 130 ELEC - Conduit Item: 140 ELEC -Misc. Item: 190 ELEC -Final Requested Time: 09:00 AM Phone: (303) 455 -2825 Entered By: JMONDRAGON K 57o 13 REPT131 Run Id: 10481 M09 -0164 : Entries for Item:390 - MECH -Final 15:22 01/16/2013 Action Comments By Date Unique_ Key AP INCLUDES GAS PIPING C9 11/19/2009 A000129 837 Total Rows: 1 Page 1