Loading...
HomeMy WebLinkAboutB08-0348NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES 7MOF VE ' Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139, f. 970.479.2452, inpsections 970.479.2149 ADD/ALT COMM BUILD PERMT Permit Project Status : Applied Issued Expires B08-0348 Job Address: 841 VAIL VALLEY DR VAIL Location......: BETTY FORD ALPINE GARDENS Parcel No....: 210108100002 OWNER TOWN OF VAIL C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 APPLICANT NIKI WOODWORKING PO BOX 5581 EAGLE COLORADO 81637 License: 970-B CONTRACTOR NIKI WOODWORKING PO BOX 5581 EAGLE COLORADO 81637 License: 970-B 09/29/2008 09/29/2008 Phone: (970) 376-6562 ISSUED 09/29/2008 10/22/2008 04/20/2009 09/29/2008 Phone: (970) 376-6562 Description: REPLACE THREE PEDESTRIAN BRIDGES Occupancy: Type Construction: Valuation: $45,000.00 Total Sq Ft Added: 0 FEE SUMMARY Building Permit Fee------ > $593.25 Will Cal Fee--------------------- > $4.00 Total Calculated Fees > $1,682.86 Plan Check--------------------> $385.61 Use Tax Fee--------------------- > $700.00 Additional Fees-----------------------> $1,682.86) Add'I Plan Check Hours-> $0.00 Restuarant Plan Review-----> $0.00 TOTAL PERMIT FEES--------------> $0.00 Investigation-----------------> $0.00 Recreation Fee-----------------> $0.00 Payments > $0.00 Total Calculated Fees--------> $1,682.86 BALANCE DUE------------------------ > $0.00 DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4:00 PM. Signature of Owner or Contractor Date Print Name bld_alt_construction_permit_041908 APPROVALS Permit B08-0348 as of 10-22-2008 Status: ISSUED Item: 05100 BUILDING DEPARTMENT 10/09/2008 jplano Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0348\B08-0348. DOC 10/16/2008 jplano Action: AP corrections addressed Item: 05400 PLANNING DEPARTMENT 10/07/2008 RLF Action: AP Item: 05500 PUBLIC WORKS 10/03/2008 tk Action: AP See the Conditions section of this Document for any that may apply. bld_alt_construction_permit_041908 CONDITIONS OF APPROVAL Permit B08-0348 as of 10-22-2008 Status: ISSUED Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. bld_a It-co nstruction_pe rm it_041908 Development Review Coordinator "r! Of Vail 75 South Frontage Road n Vail, CO 81657 e PAL' 4 L Phone; 970-479-2128 Fax: 970-479-2.172 Inspections: 970-4.79_-2149 BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, fireplace, etc Project Address 't~,e4i j l ()e- G~,rc&ns Project c- PGL r ) Vol~~ DRB# D 30 L13 Contractor Information Building Permit Company: N I K' w0eo(worKk~n ayld T rn ~+,5 LLG Detailed Description of Work: Company Address: 3D X J g I ;ep~Q.C~ 3 d, r 1 a City: ' I State: CO Zip: g I ~e 3 I Contact Name: , ~lI 0 kl~- a 0.►2~ p Contact Ph: 3 (,p CP 55 a Cell: :5a Wf -l e- E-Mail: kA t k 1 1- (PI C__ (fvr h Town of Vail Contractor Registration No: X~ Contractor t ature required) Property Information Parcel A 10 10 e I OC OC Legal Description: Lot # I n -e_ (Use additional sheet if necessary) Architect Designer( ) Engineer( ) Phone: Fax: E-Mail: Work Class: yt~yti-~- New ( ) Addition ( ) Remodel ( ) Repair ( ) Other ( ) Blk # Work Type: Subdivision: T~) rc~ Pet y- k UVI I q ~?G+ Interior ( ) Exterior (,~o Both ( ) II ff~I FO ('i~ t n Gc~ Building Type: $ri d e_ ~~p lace d Job Name: [32fT"1 f 7 I °L C'a r tPlaCe' S ni gle-Famr4y-f--) am> l ( ) Multi-Family ( ) Owner Name:?) e I ~ rJ I P I ~ ~ V~115 Commercial ( ) Townhome ( ) Other Va~`1, CO Mailing Address: pr. $1 /a 5 # & hype of Existing Fireplaces: Gas Appliance ) (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or Gas Lbg_( ) Wood/Pellet ( ) Wood Bur r>g ( ) visit www.eaglecounty.us/patie) Valuations (Labor & Material) & Type of Propo-, ed Fireplaces: GGa Appliances ( ) ~ Ups Gas Log ( )Wood/P~~t ( Wood Burning ( ) Building $ Plumbing $ Electrical $ Mechanical $ Does a Fire Alarm Exi : es ( ) No ) Monitored AZprinklerSystern es ( ) No( Does a Fire Exist: Yes ( ) No ( ) Date Received Total $~_d d A J Ctn n e b'e 9fy ~►c(ct I N~ ne'_9 a rL~Yl5 , e i''C Ph" 1-f la Ot 0 3 x~ Revision Submittals: 1. "Field Set" of approved plans MUST accompany revisions 2. No further inspections will be performed until the revisions are approved & the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour (2 hour minimum), and are due upon issuance. Revisions Permit ##(s) information applies to: Attention: ~~C." CAS ~ ~ 3 J ~'-1 Project Address: Response to Correction Letter r -attached copy of correction letter t C ~L O Deferred Submittal Other C ~ ~ ~ t ~ ! if ~ e.--c.~ t~~ v`-~_ Contact Information t Company: _ ft L y' I I r C~~( zGC'~V Company Ph: i+1 4- Gi ) Fax: Contact Name: A t IV 1 VU V_ Y 01 Contact Ph: V ' 010 3 ~ (e, Cell: 619 E-Mail: Cd h r~% k>E'~lZj~c'FC~cz~ p,r~{rZ'I~(~75. ~r~ Town of Vail Contractor Registration No: Signature (required) Revised ADDITIONAL Valuations (Labor & Materials) (DO NOT include original valuation) Building $ Plumbing $ Electrical $ Mechanical $ Fire Sprinkler/Alarm $ Total $ Description / List of Changes: 1 i Dc f~ c^ (,(aF r^ -Ce v- G4 (Use additional sheet if necessary) Date Received: OCT 1 11 2008 J TOWN OF VAIL Transmittal Form L - t50boyle engineering, inc. 16 e. llridge unit c-4 D fa vail, colorado 81657 (970) 476-4170 fax (970) 476-4383 September 22, 2008 Ann Kurronen Betty Ford Alpine Gardens 183 Gore Creek Drive Vail, Colorado 81657 Subject: Footbridge Concrete Abutments Betty Ford Alpine Gardens Vail, Colorado Dear Ann: At your request I have made a physical inspection of the existing concrete abutments for the footbridges at the Betty Ford Alpine Gardens. Specifically, I studied the three bridge locations at the primary water feature in the gardens. The bridge has been removed at the longest span over the pond, but the other two short bridges are still in place over the cascade above this pond. Cast-in-place concrete abutments have supported all three of these bridges. I scrutinized two abutments at all three of these bridge locations during this inspection. The purpose of this investigation was to determine if these abutments have the structural integrity to support new bridges at all three locations. I was unable to visually assess 100% of these concrete structures during this inspection due to stone and wood that was partially covering the concrete. However, I was able to observe enough of the concrete at all six of the locations to arrive at a reasonable assessment of their structural condition. Based upon what I observed, I am 99% certain that the concrete in all of these abutments is structurally sound and that they will be capable of supporting the new bridge structures. Since this conclusion is based upon a partial observation of these structures, it may be prudent for me to make one more visit to the site once the existing bridges are removed and I can view all of the exposed concrete in these abutments. Feel free to give me a call if you have any questions or comments on this PO f 6IS X41, Sincerely00, e, .yo •M~cF+gFf /I 1 A / v lti'r ~o T. M. Boyll0 N AV TMB/dn i Western Wood Structures, Inc. PO Box 130 Tualatin, Oregon 97062 Voice: (503) 692-6900 Fax: (503) 692-6434 N D OCT 14 zoos D TOWN OF VAIL Structural Design Calculations For: BRIDGES Designer: JB Alpine Bridge Repairs -11' & 17' Vail, Colorado WWSI Job No. 084041 October 10, 2008 30 REd,'hill 34423 1, / The attached calculations ( 21 Sheets) show the span and loading conditions and product design/selection for the above referenced project. The engineer's stamp is to confirm that these products are designed in accordance with published manufacturer's specifications or standard engineering practices. If the loads, spans, or spacings are incorrect or incomplete, notify Western Wood Structures, Inc. immediately. Neither engineer nor Western Wood Structures, Inc. can be responsible for the design or manufacture of these products if altered or used in any other manner not shown specifically on these calculations nor are they responsible for any other portion of the supporting structure unless noted otherwise. WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET ~2 OF _ JOB NO. 084041 ALPINE BRIDGE REPAIRS -11' BRIDGE VAIL, COLORADO DESIGN CRITERIA BRIDGE SPAN: 11.00 FT. - OUT TO OUT GIRDERS DESIGN SPAN: 10.50 FT. - C.L. TO C.L. BEARINGS DESIGN WIDTH: 6.00 FT. - OUT TO OUT GIRDERS LIVE LOAD: 100.00 PSF. ALLOWABLE LIVE LOAD DEFLECTION: L/ 360 WIND LOAD: WIND SPEED = 90MPH. - EXPOSURE C I SEISMIC SE S1 Ss I Rw 1.0 LOAD: ISMIC SITE CLASS D = 0.068 = 0.285 1.0 3 USE 0 DIAPHRAGMS AT 11.00 FT. O/C. ADDITIONAL NOTES: WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET OF JOB NO. 084041 ALPINE BRIDGE REPAIRS -11' BRIDGE VAIL, COLORADO DECK DESIGN USE 2.500 IN. - COMB. 2 GLULAM DECK. USE WET STRESSES FOR DECK S = 11.72 IN.' A = 30.00 IN.2 I = 15.63 IN.4 CLEAR SPAN = 5.146 FT. DESIGN SPAN = CLEAR SPAN + 1/2 GIRDER WIDTH - (AASHTO 3.25.1.2) 5.3542 FT. WDL = 10.42 PLF. WLL = 100.00 PLF. MDL = 37.33 FT. -LBS. MLL = 358.34 FT. -LBS. fb = (MDL + MLL) *12/S = 405.16 PSI. Fb = 1,800.00 PSI. Cm = 0.80 Cf = 1.00 Cfu = 1.19 F'b = Fb * Cm * Cf * Cfu = 1,713.60 PSI. VDL = WDL * (L/2 - d/12) = 25.72 LBS. VLL = WLL * (L/2 - d/12) = 246.88 LBS. fv = 3* (VDL + VLL) / (2*A) = 13.63 PSI. Fv = 230.00 PSI. Cm = 0.88 F', = Fv * Cm = 201.25 PSI. L.L. DEFL = 0.084 IN. = L/ 769.12 WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET OF _ JOB NO. 084041 ALPINE BRIDGE REPAIRS -11' BRIDGE VAIL, COLORADO GIRDER DESIGN USE 3.125 IN. X 9.0 IN. - 24F-V4 GLULAM GIRDERS. USE WET STRESSES FOR GIRDERS S = 42.19 IN.3 A = 28.13 IN.2 I = 189.84 IN.' GIRDER DEAD LOAD MISC. = 27.32 PLF. DECK = 31.25 PLF. GIRDER = 9.77 PLF. WDL = 6 8 . 3 3 PLF. MDL = WDL * L2/ 8 = 941.72 FT. LBS. WLL = 100.00 PSF. * 2.82 FT. = 282.29 PLF. MLL = WLL * L2/8 = 3, 8 9 0 . 3 3 FT. LBS. fb = (MDL + MIL) *12/S = 1,374.45 PSI. Fb = 2,400.00 PSI. Cm = 0.80 Cv = 1.1590 Cl = 0.9517 - CONTROLS F'b = Fb * Cm * Cl = 1,827.26 PSI. VDL = WDL * (L/2 - d/12) = 307.50 LBS. VLL = WLL * (L/2 - d/12) = 1,270.31 LBS. f, = 3* (VDI + VLL) / (2 *A) = 84.15 PSI. F, = 265.00 PSI. Cm = 0.88 F' = F„ * Cm = 231.88 PSI. L.L. DEFL = 0.271 IN. = L/ 465 GIRDER BEARING LENGTH DEAD LOAD REACTION = 375.83 LBS. LIVE LOAD REACTION = 1,552.60 LBS. FC(PERP) = 650.00 PSI. CM = 0.53 REQUIRED BEARING LENGTH = 1.79 IN. BEARING LENGTH PROVIDED = 6.00 IN. JOB NO. 084041 ALPINE BRIDGE REPAIRS -11' BRIDGE VAIL, COLORADO LATERAL LOAD RESISTING DESIGN WIND LOADING PROJECTED HEIGHT = 36.85 IN. SEISMIC LOADING WEIGHT = 136.67 PLF. Western Wood Structures, Inc. P.O. Box 130 - Tualatin, Oregon 97062 July 31, 2008 (503) 692-6900 Alpine Birdge Repairs - 11' Bridge Vail, CO Job Number: 084041 LATERAL LOAD DESIGN: Width of Bridge = Wind Speed V3S= 90 mph Height of Bridge = Exposure = C Weight of Bridge (per foot): W = KZ = 0.85 (ASCE 7-05 Table 6-3) Length of Bridge = KZ, = 1.00 (ASCE 7-05 Sec 6.5.7.2 & Fig. 6-4) Span of Bridge: L = Kd = 0.85 (ASCE 7-05 Sec 6.5.4.4 & Table 6-4) Girder Spacing: s = I = 1.00 (ASCE7-05 Sec 6.5.5 & Table 6-1) Velocity Pressure: qZ = 0.00256 * KZ * KZ, * Kd * V' 4` I Ext. Girder Width: be = Velocity Pressure: qz = 14.98 Ext. Girder Depth: de = G = 0.85 Cf= 130 (Figure 6-20) Wind Pressure: F/Af = q2 * G * C f Wind Pressure: F/A f = 16.6 psf EY = Projected Height: H = 36.85 in. C,,, _ E'Y = Wind Load = F/Af * H / 12 Wind Load = 50.84 plf a Controls Page ~ of 6.0 ft. 10.0 ft. 137 PLF 11.0 ft. 10.5 ft. 68.88 in. 3.125 in. 9.0 in. 1600000 psi 0.833 1332800 psi ****Seismic Site Class = D SMs = 0.4560 Seismic Use Group = I SDS = 0.3040 R = 3 (Ordinary Steel Concentrically Braced Frame) SMI = 0.1632 SS = 0.285 (See attached) SD, = 0.1088 S, = 0.068 (See attached) TS = 0.3579 I = 1.000 (ASCE7-05 Sec 11.5.1 & Table 11.5-1) TL = 6 Fa = 1.600 (ASCE7-05 Sec 11.4.3 & Table 11.4-1) Fv = 2.400 (ASCE7-05 Sec 11.43 & Table 11.4-2) Seismic Design Category = D (ASCE7-05 Sec 11.6 & Tables 11.6-1 & 11.6-2) Mass of Bridge: m = W / ((L * 12) * 32.2 * 12) m = 0.0294751 lb*sec^2/in^2 Ieff= 2 * de * be^3 / 12 (for deflection calcs.) Ieff= 46 in.-4 leff-com = 2 * [de * be^3 / 12 + de * be * (s/2)^2] (for period calc.) p leff-comp = 66755 in.^4 Period of Bridge: T = 2 / pi * [(E' *Ieff) / (m * L4)] 1/2) (Structural Dynamics, Mario Paz) T = 0.0058 sec. Western Wood Structures, Inc. P.O. Box 130 - Tualatin, Oregon 97062 July 31, 2008 (503) 692-6900 Alpine Bridge Repairs - 11' Bridge Vail, CO Job Number: 084041 LATERAL LOAD DESIGN: (Continued) E= /)*QE=p*V 1.3 V= C,*W/L C,= SDS/(R/I) CS = 0.101 If T < TL, Cs need not be greater than: C,=SDI/[T*(R/I)] C, = 6.234 If T > TL, Cs need not be greater than: C, = SD, *TL / [ T- * (R/ I)] C, = Does not apply (ASCE 7-05 Eq 12.4.3) (ASCE 7-05 Sec. 12.3.4) (ASCE 7-05 Eq 12.8-1) (ASCE 7-05 Eq 12.8-2) (ASCE 7-05 Eq 12.8-3) (ASCE 7-05 Eq 12.8-4) Cs shall not be less than: CS = 0.010 If S, > 0.6g, Cs shall not be less than C, = 0.5*S, / (R / 1) Cs = Does not apply Cs= 0.101 V = 13.85 plf E=p* V= 18.00 Of Seismic Load = E/1.4 = 12.86 plf Wind Load Controls Lateral Load Design. (2006 IBC Section 1605.3.2 Eq. 16-18) Lateral Load Deflection = 0.282 in. L / 447 < L/180 OK Rod Bracing System Is Not Required. (ASCE 7-05 Eq 12.8-5) (ASCE 7-05 Eq 12.8-6) Page of Conterminous 48 States 2006 International Building Code Latitude = 39.6278 Longitude = -106.3827 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 0.285 (Ss, Site Class B) 1.0 0.068 (S1, Site Class B) D WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET q OF JOB NO. 084041 ALPINE BRIDGE REPAIRS - 17' BRIDGE VAIL, COLORADO DESIGN CRITERIA BRIDGE SPAN: 17.00 FT. - OUT TO OUT GIRDERS DESIGN SPAN: 16.50 FT. - C.L. TO C.L. BEARINGS DESIGN WIDTH: 6.00 FT. - OUT TO OUT GIRDERS LIVE LOAD: 100.00 PSF. ALLOWABLE LIVE LOAD DEFLECTION: L/ 360 WIND LOAD: WIND SPEED = 90MPH. - EXPOSURE C I SEISMIC SE S1 Ss I Rw 1.0 LOAD: ISMIC SITE CLASS D = 0.068 = 0.285 1.0 = 3 USE 0 DIAPHRAGMS AT 17.00 FT. O/C. ADDITIONAL NOTES: WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET jo OF JOB NO. 084041 ALPINE BRIDGE REPAIRS - 17' BRIDGE VAIL, COLORADO DECK DESIGN USE 2.500 IN. - COMB. 2 GLULAM DECK. USE WET STRESSES FOR DECK S = 11.72 IN.3 A = 30.00 IN.2 I = 15.63 IN.4 CLEAR SPAN = 5.146 FT. DESIGN SPAN = CLEAR SPAN + DECK THICKNESS - (AASHTO 3.25.1.2) 5.3542 FT. WDL = 10.42 PLF. WLL = 100.00 PLF. MDL = 37.33 FT. -LBS. MLL = 358.34 FT. -LBS. fb = (MDL + MIL) *12/S = 405.16 PSI. Fb = 1,800.00 PSI. Cm = 0.80 Cf = 1.00 Cfu = 1.19 F'b = Fb * Cm * Cf * Cfu = 1,713.60 PSI. VDL = WDL * (L/2 - d/12) = 25.72 LBS. VLL = WLL * (L/2 - d/12) = 246.88 LBS. f„ = 3* (VDL + VLL) / (2*A) = 13 .63 PSI. F" = 230.00 PSI. Cm = 0.88 F'v = Fv * Cm = 201.25 PSI. L.L. DEFL = 0.084 IN. = L/ 769.12 WESTERN WOOD STRUCTURES, INC. PBRIDGE - Version 2.00 - Copyright 1992 - All Rights Reserved P.O. BOX 130 - TUALATIN, OREGON 97062 JUL. 31, 2008 503/692-6900 SHEET l~ OF JOB NO. 084041 ALPINE BRIDGE REPAIRS - 17' BRIDGE VAIL, COLORADO GIRDER DESIGN USE 5.125 IN. X 12.0 IN. - 24F-V4 GLULAM GIRDERS. USE WET STRESSES FOR GIRDERS S = 123.00 IN.' A = 61.50 IN.2 I = 738.00 IN.4 GIRDER DEAD LOAD MISC. = 25.10 PLF. DECK = 31.25 PLF. GIRDER = 21.35 PLF. WDL = 77.70 PLF. MDL - WDL * L2/8 = 2,644.38 FT. LBS. WLL = 100.00 PSF. * 2.82 FT. = 282.29 PLF. MLL - WLL * L2/8 = 9,606.74 FT. LBS. fb = (MDL + MLL) *12/S = 1,195.23 PSI. Fb = 2,400.00 PSI. Cm = 0.80 Cv = 1.0244 C1 = 0.9687 - CONTROLS F'b = Fb * Cm * C1 = 1,859.84 PSI. VDL = WDL * (L/2 - d/12) = 563.36 LBS. VLL = WLL * (L/2 - d/12) = 2,046.61 LBS. fv = 3* (VDL + VLL) / (2 *A) = 63.66 PSI. Fv = 265.00 PSI. Cm = 0.88 F' = Fv * Cm = 231.88 PSI. L.L. DEFL = 0.425 IN. = L/ 466 GIRDER BEARING LENGTH DEAD LOAD REACTION = 660.49 LBS. LIVE LOAD REACTION = 2,399.48 LBS. FC(PERP) = 650.00 PSI. CM = 0.53 REQUIRED BEARING LENGTH = 1.73 IN. BEARING LENGTH PROVIDED = 6.00 IN. JOB NO. 084041 ALPINE BRIDGE REPAIRS - 17' BRIDGE VAIL, COLORADO LATERAL LOAD RESISTING DESIGN WIND LOADING PROJECTED HEIGHT = 39.54 IN. SEISMIC LOADING WEIGHT = 155.41 PLF. Western Wood Structures, Inc. P.O. Box 130 - Tualatin, Oregon 97062 July 31, 2008 (503) 692-6900 Page IS of Alpine Budge Repairs - 17' Bridge Vail, CO Job Number: 084041 LATERAL LOAD DESIGN: Width of Bridge = 6.0 ft. Wind Speed V3S= 90 mph Height of Bridge = 10.0 ft. Exposure = C Weight of Bridge (per foot): W = 155 PLF KZ = 0.85 (ASCE 7-05 Table 6-3) Length of Bridge = 17.0 ft. KZ, = 1.00 (ASCE 7-05 Sec 6.5.7.2 & Fig. 6-4) Span of Bridge: L = 16.5 ft. Kd = 0.85 (ASCE 7-05 Sec 6.5.4.4 & Table 6-4) Girder Spacing: s = 68.88 in. I = 1.00 (ASCE7-05 Sec 6.5.5 & Table 6-1) Velocity Pressure: qZ = 0.00256 * KZ * KZt * Kd * V' 4:1 Ext. Girder Width: be = 5.125 in. Velocity Pressure: qZ = 14.98 Ext. Girder Depth: de = 12.0 in. G = 0.85 Cf = 130 (Figure 6-20) Wind Pressure: F/Af= qZ * G * Cf Wind Pressure: F/Af = 16.6 psf Ey = 1600000 psi Projected Height: H = 39.54 in. C,,, = 0.833 E'y = 1332800 psi Wind Load = F/Af * H / 12 Wind Load = 54.55 plf G Controls ****Seismic Site Class = D SMs = 0.4560 Seismic Use Group = I SDS = 0.3040 R = 3 (Ordinary Steel Concentrically Braced Frame) SMt = 0.1632 SS = 0.285 (See attached) SDI = 0.1088 S, = 0.068 (See attached) TS = 0.3579 I = 1.000 (ASCE7-05 Sec 11.5.1 & Table 11.5-1) TL = 6 Fa = 1.600 (ASCE7-05 Sec 11.4.3 & Table 11.4-1) F = 2.400 (ASCE7-05 Sec 11.4.3 & Table 11.4-2) Seismic Design Category = D (ASCE7-05 Sec 11.6 & Tables 11.6-1 & 11.6-2) Mass of Bridge: m = W / ((L * 12) * 32.2 * 12) m = 0.03351661b*sec^2/in^2 Ieff= 2 * de * be^3 / 12 (for deflection calcs.) Ieff = 269 in.^4 Ieff-co,»p = 2 * [de * be^3 / 12 + de * be * (s/2)^2] (for period calc.) Ieff-comp = 146140 in.^4 Period of Bridge: T = 2 / {pi * [(E' * Teff) / (m * L4)]1/2} (Structural Dynamics, Mario Paz) T = 0.0 104 sec. Western Wood Structures, Inc. P.O. Box 130 - Tualatin, Oregon 97062 July 31, 2008 (503) 692-6900 Alpine Birdge Repairs - 17' Bridge Vail, CO Job Number: 084041 LATERAL LOAD DESIGN: (Continued) E= /)*QE=/)*V 1.3 V= C,*W/L C, = SDS / (R / I) CS = 0.101 If T < TL, Cs need not be greater than: C, = Sp, / [ T * (R / I)] C, = 3.503 If T > TL, Cs need not be greater than: C, = Sp, *TL / [ T' * (R / 1)] C, = Does not apply (ASCE 7-05 Eq 12.4.3) (ASCE 7-05 Sec. 12.3.4) (ASCE 7-05 Eq 12.8-1) (ASCE 7-05 Eq 12.8-2) (ASCE 7-05 Eq 12.8-3) (ASCE 7-05 Eq 12.8-4) Cs shall not be less than: CS = 0.010 If S, > 0.6g, Cs shall not be less than CS= 0.5*Sl /(R/1) Cs = Does not apply Cs= 0.101 V = 15.75 plf E = p * V = 20.47 plf Seismic Load = E/1.4 = 14.62 plf Wind Load Controls Lateral Load Design. (2006 IBC Section 1605.3.2 Eq. 16-18) Lateral Load Deflection = 0.254 in. L / 781 < L/180 OK Rod Bracing System Is Not Required. (ASCE 7-05 Eq 12.8-5) (ASCE 7-05 Eq 12.8-6) Page /y of DATE WESTERN WOOD STRUCTURES, INC. PROJECT r-INf n t,,,, R 4 S LOCATION cocgLlAt)0 P.O. BOX 130, TUALATIN, OREGON 97062 SHEET 503/692-6900 FAX 503/692-6434 JOB NO. ~A f4~u~r BY S3 /,r OF ~NEGk S ozx C~3 v FA/ f co,gq CJ Fc e- L' y Irsfb.v M x S SEAnVtyS poo (+t 3 ~b S-OH TD b._ wN£Ct I_b - /AAK G- in ova Og s r 6,~/ a~ ~ ~ s~~ SRS r I sic ArrAc.kr,y Doti ~AceucArinvs 10 COMPANY PROJECT ~i Western Wood Structures, Inc. WoodWorks PO Box 130 Tualatin, OR 97062 s[>rrunar roe wood ne.uc:n 503-692-6900 Oct. 10, 2008 10:05 11'&17'Deck.wwb Design Check Calculation Sheet Sizer 7.1 LOADS ( ibs, psf, or plf ) Load Type Distribution Magnitude Location [ftj Units Start End Start End Loadl Dead Full UDL 13.0 plf Load4 Live Point 2000 0.29 lbs Load3 Live Point 2000 5.29 lbs MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : 0' 5' Dead 36 36 Live 2000 2000 Total 2036 2036 Bearing: Load Comb #2 #2 Length 2.74 2.74 Glulam-Unif., West Species, 2 (DF L2), 2-1/2x15" Service: wet; Lateral support: top= at supports, bottom= at supports; Oblique angle: 90.0 [deg]; WARNING: this CUSTOM SIZE is not in the database. Refer to online help. Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: Criterion Analysis Value Desi n Value Analysis/Design Shear x-x fv = 0 Fv' = 241 fv/Fv' = 0.00 y-y fv = 81 Fv' = 211 fv/Fv' = 0.38 Biaxial fvx / Fvx' + fvy / Fvy' = 0.38 Bending(+) x-x fb = 0 Fb' = 1467 fb/Fb' = 0.00 y-y fb = 479 Fb' = 1971 fb/Fb' = 0.24 Biaxial 3.9-3: fbl/Fbl' fb2/Fb2 '/(1-(fbl FbE)^2) = 0.24 Live Defl'n -0.15 = L/454 0.19 = L/360 0.79 Total Defl'n -0.16 = L/409 0.28 = L/240 0.59 l-7 ADDITIONAL DATA: FACTORS: F/E CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# Fv' 240 1.15 0.88 1.00 - - - - 1.00 1.00 1.00 2 Fvy' 210 1.15 0.88 1.00 - - - - 1.00 1.00 - 2 Fb'+ 1700 1.15 0.80 1.00 0.938 1.000 1.00 1.00 1.00 1.00 - 2 Fby' 1800 1.15 0.80 1.00 1.000 1.000 1.19 1.00 1.00 1.00 - Fcp' 560 - 0.53 1.00 - - - - 1.00 - - - E' 1.6 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - Ey' 1.6 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - 2 Custom duration factor for Live load = 1.15 Shear : LC #2 = D+L, V = 2036, V design = 2034 lbs Bending(+): LC #2 = D+L, M = 623 lbs-ft Deflection: LC #2 = D+L EI= 1125e06 lb-in2 EIy= 31e06 lb-in2 Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow w=wind I=impact C=construction CLd=concentrated) (All LC's are listed in the Analysis output) Load combinations: ICC-IBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSUAITC A190.1-1992 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). !d) COMPANY PROJECT Western Wood Structures, Inc. WoodWorks 't PO Box 130 Tualatin, O R 97062 503-692-6900 Oct. 10, 2008 10:05 11'&17'Deck.wwb Design Check Calculation Sheet Sizer 7.1 LOADS (Ibs, psf, or plf ) Load Type Distribution Magnitude Location [ft] Units Start End Start End Loadl Dead Full UDL 13.0 plf Load4 Live Point 2000 0.00 lbs Load3 Live Point 2000 5.00 lbs MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : Dead 36 36 Live 2206 1794 Total 2242 1831 Bearin : g Load Comb #2 #2 Length 3.02 2.47 Glulam-Unif., West Species, 2 (DF 1-2), 2-1/2x15" Service: wet; Lateral support: top= at supports, bottom= at supports; Oblique angle: 90.0 [deg]; WARNING: this CUSTOM SIZE is not in the database. Refer to online help. Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: Criterion Analysis Value Design Value Analysis/Design Shear x-x fv = 0 Fv' = 241 fv/Fv' = 0.00 y-y fv = 73 Fv' = 211 fv/Fv' = 0.35 Biaxial fvx / Fvx' + fvy / Fvy' = 0.35 Bending(+) x-x fb = 0 Fb' = 1467 fb/Fb' = 0.00 y-y fb = 804 Fb' = 1971 fb/Fb' = 0.41 Biaxial 3.9-3: fbl/Fbl' fb2/Fb2 '/(1-(fbl FbE)^2) = 0.41 Live Defl'n -0.15 = L/459 0.19 = L/360 0.78 Total Defl'n -0.16 = L/413 0.28 = L/240 0.58 Ig ADDITIONAL DATA: FACTORS: F/E CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# Fv' 240 1.15 0.88 1.00 - - - - 1.00 1.00 1.00 2 Fvy' 210 1.15 0.88 1.00 - - - - 1.00 1.00 - 2 Fb'+ 1700 1.15 0.80 1.00 0.938 1.000 1.00 1.00 1.00 1.00 - 2 Fby' 1800 1.15 0.80 1.00 1.000 1.000 1.19 1.00 1.00 1.00 - 2 Fcp' 560 - 0.53 1.00 - - - - 1.00 - - - E' 1.6 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - 2 Ey' 1.6 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - 2 Custom duration factor for Live load = 1.15 Shear : LC #2 = D+L, V = 1831, V design = 1828 lbs Bending(+): LC #2 = D+L, M = 1047 lbs-ft Deflection: LC #2 = D+L EI= 1125e06 lb-in-2 EIy= 31e06 lb-in2 Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrat ed) (All LC's are listed in the Analysis output) Load combinations: !CC-IBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordan ce with ANSUAITC A190.1-1992 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). ` t' F + WoodWork COMPANY Western Wood Structures, Inc. PO B 130 PROJECT J s:3rrssaurruuWOOD t> csrc; Tualatin, , OR 97062 . 503-692-6900 Oct. 10, 2008 09:30 11'Girder.wwb Design Check Calculation Sheet Sizer 7.1 LOADS ( Ibs, psf, or plf ) Magnitude I Start End Start End G LENGTHS (in) : 10' 10'-6'i Fv' 265 1.15 0.88 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 2400 1.15 0.80 1.00 0.947 1.000 1.00 1.00 1.00 1.00 - 2 Fcp' 650 - 0.53 1.00 - - - - 1.00 - - - E' 1.8 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - 2 Custom duration factor for Live load = 1.15 Shear : LC #2 = D+L, V = 1307, V design = 1264 lbs Bending(+): LC #2 = D+L, M = 6057 lbs-ft Deflection: LC #2 = D+L EI= 342e06 lb-in2 Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. (D=dead L=live S=snow W=wind I=impact C=construction CLd=concentrated) (All LC's are listed in the Analysis output) Load combinations: ICC-IBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSUAITC A190.1-1992 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). Load Type Dist ribution Location [ft] Units Loadl Dead Full UDL 58. 6 plf Load2 Live Point 2000 5.25 lbs MAXIMUM REACTIONS (Ibs) and BEARIN Dead 307 307 Live 1000 1000 Total 1307 1307 Bearin : g Load Comb #2 #2 Leng th 1.2 1 .21 Glulam-Unbal., West Species, 24F-1.8E WS, 3-118x9" Service: wet; Lateral support: top= at supports, bottom= at supports; Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005 : ADDITIONAL DATA: CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# 1 FACTORS: F/E CD Criterion Analysis Value Design Value Anal sis/Desi n Shear fv = 67 Fv' = 267 fv/Fv' = 0.25 Bending(+) fb = 1723 Fb' = 2091 fb/Fb' = 0.82 Live Defl'n 0.29 = L/930 0.35 = L/360 0.84 Total Defl'n 0.38 = L/339 0.52 = L/240 0.72 21 COMPANY PROJECT Wood Works Western Wood Structures, Inc. PO Box 130 Tualatin, OR 97062 r503-692-6900 Oct. 10, 2008 10:29 17'Girder.wwb Design Check Calculation Sheet Sizer 7.1 LOADS ( Ibs, psf, or plf ) Load Type Distribution Magnitude Location [ft] Units Start End Start End Loadl Dead Full UDL 58.6 plf Load2 Live Point 2000 7.45 lbs Load3 Live Point 500 15.45 lbs MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : Dead 483 483 Live 1129 1371 Total 1612 1854 Bearin : g Load Comb #2 #2 Length 0.91 1.05 Glulam-Unbal., West Species, 24F-1.8E WS, 5-1/8x12" Service: wet; Lateral support: top= at supports, bottom= at supports: Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: Criterion Analysis Value Design Value Analysis/Design Shear Bending(+) Live Defl'n Total Defl'n fv = 44 fb = 1013 0.30 = L/655 0.43 = L/455 Fv' = 267 Fb' = 2132 0.55 = L/360 0.83 = L/240 fv/Fv' = 0.16 fb/Fb' = 0.48 0.55 0.53 ADDITIONAL DATA: FACTORS: F/E CD CM Ct CL CV Cfu Cr Cfrt Notes Cn LC# Fv' 265 1.15 0.88 1.00 - - - - 1.00 1.00 1.00 2 Fb'+ 2400 1.15 0.80 1.00 0.965 1.000 1.00 1.00 1.00 1.00 - 2 Fcp' 650 - 0.53 1.00 - - - - 1.00 - - - E' 1.8 million 0.83 1.00 - - - - 1.00 - - 2 Emin' 0.85 million 0.83 1.00 - - - - 1.00 - - 2 Custom durati on fact or for Live load = 1.15 Shear : LC #2 = D+L, V = 1854, V design = 1796 lbs Bending(+): LC #2 = D+L, M = 10384 lbs-ft Deflection: LC #2 = D+L EI= 1328e06 lb-in2 Total Deflection = 1.50(De ad Load Deflection) + Live Load Deflection. (D=dead L =live S=snow w=wind I=impact C=construction CLd=concentrat ed) (All LC's are lis ted in the Analysis output) Load combinations: ICC-IBC DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application. 2. Glulam design values are for materials conforming to AITC 117-2001 and manufactured in accordance with ANSI/AITC A190.1-1992 3. GLULAM: bxd = actual breadth x actual depth. 4. Glulam Beams shall be laterally supported according to the provisions of NDS Clause 3.3.3. 5. GLULAM: bearing length based on smaller of Fcp(tension), Fcp(comp'n). B08 -0348 : Entries for Item-90 - BLDG -Final 09:38 01/23/2013 Action Comments % By Date Unique_ Key AP 3 pedestrian bridges ok _ NSC 09/14/2009 A000127 450 Total Rows: 1 Page 1