Loading...
HomeMy WebLinkAboutM09-0096 E09-0179NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWW0FVA Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970 - 479 -2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ACOM Job Address: 241 E MEADOW DR VAIL Location.....: VAIL TRANSP. CENTER Parcel No...: 210108227002 OWNER TOWN OF VAIL 06/23/2009 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 APPLICANT R & H MECHANICAL LLC PO BOX 810 EAGLE CO 81631 License: 184 -M CONTRACTOR R & H MECHANICAL LLC PO BOX 810 EAGLE CO 81631 License: 184 -M 06/23/2009 Phone: (970) 328 -2699 06/23/2009 Phone: (970) 328 -2699 Desciption: REPLACE BOILER WITH TWO BOILERS Valuation: $142,910.00 J Mechanical Permit Fee - -> $2,860.00 Will Call------ - - - - -> $4.00 Total Calculated Fees --- > $6,237.20 Plan Check — ----------------- > $715.00 Use Tax Fee - - ---> $2,658.20 Additional Fees ------- - - -> $6,237.20) Investigation------------ - - - - -> $0.00 TOTAL PERMIT FEE --- > $0.00 Total Calculated Fees - -> $6,237.20 Payments------------ - - - - -> $0.00 BALANCE DUE --------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 06/25/2009 JRM Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. ALL TIMES Permit #: M09 -0096 Project #: PRJ09 -0264 Status ...: ISSUED Applied..: 06/23/2009 Issued . .: 09121/2009 Expires . .: 03/20/2010 mechcan ical_pe rmit_041908 DECLARATIONS I hereb )t acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS F 4AL MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.4 9.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. 1UV# rnd1aw6f Owner Wr Contractor Date mechcanical_pe rm it_041908 4 Department of Community Development 75 South Frontage Road Vail, Colorado 81657 Tel: 970 - 479 - 212:8 Fax: 970- 479 -2452 Web: www.vailgov.com Development Review Coordinator MECHANICAL PERMIT Boiler /Furnace Applications MUST include: Mechanical Room Layout /Plan with Dimensions Combustion Air Duct Size and Location r Flue or Vent Size 2 Gas Piping Plan (if applicable) ❑ Heat Loss Calculations* n I(t S e Equipment Cut Sheets for Boiler /Furnace * Not required for same size (BTU) boiler replacement with no system changes, or snow melt P oiect Street Addr (Number) (Street) (Suite #) Building /Complex Name: Contractor lqo�mation: p � Company: `Tr l UL L AAA LLL Company Address: Pt FyY X City: / State: C O Zip: Contact Name: �� contact Phone: (1 � p � E -Mail V I�i��i�' I i& Town o Vail Contra or Registration No.: f�i'R g � x� i�,a . ti Contractor,& ( J n4ture (required) Property Information /1 Parcel #: -) J C' / — (, - ° 00 (For parcel #, contact Eagle County Assessors Office at 970- 328 -8640 or visit www.eaglecouty.us /patie) Tenant Name: Commerci I Pr perti s) Owner Name: �U% �(�- Complete Valuation for Mechanical Pq it: Mechanical $: / � 10 L Fireplace Applications MUST include: ❑ Equipment Cut Sheets for Fireplaces /Log Sets (Manufacturer's info showing make, model & approval listing) \U k 1 Office Use: A Project #: Building Permit #: Mechanical Permit #: 10q — 11 Oq U_ _ Lot #: Block Subdivision ~ (.� 1 V I W t Detailed Descripti n of Work: bbi F-4 ,---�� LZ � s lac► �� AA f (use additional sheet if necessary) ❑ Gas Piping Included ❑ Gas Piping by Others ❑ Wood to Gas Fireplace Conversion Boiler Location. Interior (X Exterior ( ) Other ( ) Number of Existing Fireplaces: 1 I A _ Gas Appliances ( ) Gas Logs ( ) Wood / ( ) Number of Proposed Fireplaces: j I � Gas Appliances ( ) Gas Logs ( ) Wood /Pellet ( ) Type of Building: Single - Family ( ) Duplex ( ) Multi - Family ( ) CommercialA) Restaurant ( ) Other Date Rece i Ep El GAS PIPING ADDED INSULATE ALL NEW PIPING WITH WHITE FlIBERGLA65 PIPING INSULATION. MATCH EXISTING THICKNESS. N.C. HW& N.C. 41; N.C. N.o. g (E) HE-2 H LUU,6 4 E NOTES: 1. ALL VALVES 4 APPURTENANCES ARE NOT SHOWN. PROVIDE AS REQUIRED FOR PROPER INSTALLATION AND MAINTENANCE. (E) E><F=-4 2. (E) = EXISTING 3. (R) = EXISTING RELOCATED 411 HWS 311, 11 1 le HW& TO BLDG. f CE) A5_4 (E) f= - (o (E) P - MIN. 24" FROM SURF RIFICATION (R) I:z -I I - Q (R) AS-3 f Ll (R) 3 11 4 4 _k- &"4) RETURN WITH BOILER. 5 T 5-4b T 3 1 —(E) EXTEND 3 MG To 50ILER5 AND DROP WITH 1 MG TO GA; TRAIN(6) ro"-P SUPPLY HEADER FURNISHED WITH 50ILEF_' NOTE; ELECTRICAL CONTRACTOR TO VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S INSTRUCTIONS. FLUE GAS OUTLET WITH MIN 2"0 REDUCTION EXIT CONE (NOZZLE) TO INCREASE VELOCITY TO DISCHARGE MOIST FLUE GASES UP AND AWAY FROM BUILDING. CONSULT WITH 5UDEf;RU!5 MANUFACTURER'S REP. (KILLAM GAS BURNER) ON BOILER VENTING. - - - - - - - - - - - - - - -------- - - - - -- C-4MNEY CAF/F,00t- (E) C.A. LOUVER W r BOILER VENT C.A. ROOM 4 g 4 < 4 I 1 BAROMETRIC DAMPER CONTROL BY OTHERS, 1 MATERIAL CHANGE I 14 ALL VENTING MATERIAL SHALL BE P& FLUE, RATED FOR PRESSURIZED APPLICATIONS, DOUBLE WALL, 304 STAINLESS STEEL INNER LINER AND ALUMINIZED STEEL OUTER WALL PER UPDATED INFORMATION FROM BOILER MANUFACTURER, 5-4a 5-4b 15 �—AROMETRIC DAMPER 4 CONTROL BY OTHERS, L EXISTING C.A. INLET TO (E) 5'x3' C.A. OPENING 5E REUSED, TO BE REUSED. 5AROMETRIC, DAMPER CONTROL BY OTHERS. SLOPE BACK TO D 50ILER MIN. I/4 JUN 2 2 2009 NEW 4" HIGH HOUSEKEEPING ------- V­_ - A - --- - -11 -- T6WN OF VAIL 50ILEF� &C�4EDULE ACCESSORIES I - RIELLO 5UFNER RS-120/m SIZED FOR OUTPUT 0 81E0' 2 - ASMIE RATED (H-STAMP) 3 - C60-1 CONTROLS 4 - 30% Pj3. 5 - NOT USED SYM. (SERVES) TYPE 6-L, INPUT M514 ALT OUTPUT M5H FUEL DELTA T ELEC. MANUFACTURER 4 MODEL AFUE ACCESSORIES PRESSURE/TEMPERATURE TEST FORT CHECK VALVE Ge POINT OF DISCONNECTION N.C. 5-4a 44b CAST [RON 2k­10 2,242 NAT, GAS 30 1 10 q� \t I V\� ro 4013 5.1 A 5UDERU5 G&15/10 MG 1,2,3,4 Fut 6CHEDULE ACCESSORIES/ NOTES SYM. GPM TDH HP VOLT/PH MANUFACTURER DESCRIPTION z 4 MODEL NO. P-11 (R)i 15a 15 1 4aO/3 BELL 4 G056ETT 1150 RPM MOTOR ao 3X3X Sequence of Operation 1. B-4a & B-4b Boilers a. Provide a two-stage modulating boiler control (MiniMOD or equal) which shall stage boilers in a "sequential modulation" arrangement to maintain HWS setpoint at temperature sensor. b. Boilers shall be rotated for equal run times. c. Include interface with existing DDC system. Items to be monitored shall include boiler command & status, pump command & status, boiler alarm, and heating water supply & return temperatures. Contact Long Building Intelligence for control assistance. 2. P -1 Boiler Pumps a. P -1 boiler pumps shall run whenever associated boiler is firing. �ENEi�AL LE r_--�ENID T TEMPERATURE SENSOR BALL VALVE C.A. COMBUSTION AIR BUTTERFLY VALVE PRESSURE/TEMPERATURE TEST FORT CHECK VALVE Ge POINT OF DISCONNECTION N.C. NORMALLY CLOSED POINT OF NEW CONNECTION N.O. NORMALLY OPEN MG MEDIUM PRESSURE GAS (2 Po"l) Cx LOW PRESSURE GAS (0- P61) NOTE: FREFAIFRI ALL LEA<,15 INTO 50ILEFR fROO�l FFP,10" TO IN&TALLATION OF NEW 150ILEF�5. NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWxO Vy Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E09 -0179 ACOM Project #: PRJ09 -0264 Job Address: 241 E MEADOW DR VAIL Status ...: ISSUED Location.....: VAIL TRANSP. CENTER Applied..: 09/23/2009 Parcel No...: 210108227002 Issued. .. 09123/2009 Expires. .: 03/22/2010 OWNER TOWN OF VAIL 09/23/2009 C/O FINANCE DEPT 75 S FRONTAGE RD VAIL CO 81657 APPLICANT DAVE PETERSON ELECTRIC P.O. BOX 711 EDWARDS CO 81632 License: 119 -E CONTRACTOR DAVE PETERSON ELECTRIC P.O. BOX 711 EDWARDS CO 81632 License: 119 -E Desciption: HOOK -UP TWO BOILERS Valuation: $1,000.00 Square feet: ...***.,..........«......*.**«.... . *. *..... * * «„ *....... «..... « *.. FEE SUMMARY *.*..«......,«*««*..*.........«*«...,*... . «.. «......... *. * *... «....,..,. Electrical Permit Fee --------- > $57.50 Total Calculated Fees - -> $61.50 Investigation Fee--------- - - - - -> $0.00 Additional Fees ---------- > ($61.50) Will Call Fee--------------- - - - - -> $4.00 Use Tax Fee ------------------- > $0.00 TOTAL PERMIT FEE --- > $0.00 Total Calculated Fees ------- > $61.50 Payments------------ - - - - -> $0.00 BALANCE DUE ---------- > $0.00 APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 09/23/2009 JLE Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. EATS FOR INSPECTIO E ROM 8:00 AM - 4 PI Signature of BE MADE TWENTY -FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR or Contractor Print Name 09/23/2009 Phone: 970-926-4140 09/23/2009 Phone: 970-926-4140 -,, Date elec_prm_041908 Sep-22. 2009 10:41AM No. 1021 P. 1 ELECTRICAL PERMIT Project Street Address: DY, (Numbel n (Street) (Suite X) :13uilding/Complex Name: XU-L\ - W VAU m ElectricalParmfi#: Contractor Information: :Company, Lot &-- Block 5 \1W VvalAt Company Address; P0 Apy, - III Detailed Description of Work: Ano� 7, City; —Ej"dLvd State: CC) zip:81(0'-�)2— z —T7— Contact Name: T2)0..\Jt Qe+tYSQ1(\ Contact Phone: 4111)) E-Ma e-PekjaJWeA&t)QC I r7c (Ow-t. (use additional sheet if necessary) TJ n of ail 7Contractv Regisp No Work Class: X Repai New Addition Addi Remodel Other r Co rector Signature (required) ... . .............. Type of Building: . ...... Duplex( Multi - Family (. Property Information Parcel A 'It o (Fbr parcel #, contact Eagle County Assessor m 01171%;cs ,t 970-328-8640 or visit ~.eaglecounty.us/palie) Date Paceived: Office Use: t Pro'ec 4Lba-- P7,e cvc B MW& it #- Tenant Name; Owner Name: f COMPLETE SQ. FOOTAGE FOR AREA OF VALU,11- '0105K AND VALUA, 'TION OF WORK (Labor & Material) 11 AND Amount of SQ Ft.: rnSEP 2 2 2009 L Electrical . ... ....... .. .... . . ................ ................... TOWN 0 TOWN o k/4 I L n Ve 29-May-09 l Z . I zqr U!J_Z0_ZUW1 Inspection Request Reporting Page 13 5:03 pm Vail , CC) _City Of Requested Inspect Date: Tuesday, September 29, 2009 Inspection Area: SH Site Address: 241 E MEADOW DR VAIL VAIL TRANSP. CENTER A/P /D Information Activity: E09 -0179 Type: B -ELEC Const Type: Occupancy: Owner: TOWN OF VAIL Contractor: DAVE PETERSON ELECTRIC Description: HOOK -UP TWO BOILERS Sub Type: ACOM Use: Phone: 970- 926 -4140 Status: ISSUED Insp Area: SH Reauested Inspection(s Item: 190 ELEC -Final Requestor: DAVE PETERSON ELECTRIC Assigned To: GDENCKLA Action: Time Exp: �a0l Requested Time: 02:00 PM Phone: 970 - 926 -4140 -or- cell 904- 6369 Entered By: JMONDRAGON K qlbij -135y Inspection History Item: 110 ELEC - Service Item: 120 ELEC -Rough Item: 130 ELEC - Conduit Item: 140 ELEC -Misc. Item: 190 ELEC -Final REPT131 Run Id: 10342 M09 -0096 : Entries for Item:390 - MECH -Final 09:18 01/17/2013 Action Comments By Date Unique_ Key AP corrections made and revised plans on site. NSC 12/17/2009 A000130 652 Total Rows: 1 Page 1