HomeMy WebLinkAboutB07-0254 PlansARRABELLE ACTIVITIE.S DESK VAI I CO ORADO AUGUST 30,2007 111 illli ijq� iii 0 A VaI Resorts Develop %.- Companv, M E L IC K A S S 0 C I A T E S I N C. SYMBOL DEVICE DESCRIPTION FACP Fire Alarm Control Panel EEI LCD Annunciator NEI Booster Power Supply U Manual Pull Station Op Photoelectric Smoke Detector Heat Detector (fixed) RT �- Duct Detector w/Test Switch 93 Horn /Strobe, wall mount C 33 Horn /Strobe, ceiling mount Strobe (candela specified) Horn Only %3 Weatherproof Horn /Strobe }- V -{ Sprinkler Waterflow Switch Sprinkler Value Tamper Switch cR Control Relay ® Single Monitor Module SECTION 15010 GENERAL PROVISIONS 1.1 GENERAL: A. ALL BIDDERS SHALL BECOME FAMILIAR WITH SITE CONDITIONS PRIOR TO SUBMITTING BIDS, B. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH LOCAL AND STATE CODES. C. EQUIPMENT SCHEDULES ESTABLISH A QUALITY AND DESIGN STANDARD. SUBSTITUTIONS MUST BE EQUIVALENT IN PERFORMANCE, MATERIAL, SPACE, AND CONFIGURATION REQUIREMENTS. THE PROJECT ENGINEER OR ARCHITECT'S DECISION WILL BE FINAL AND MAY BE BASED ON BOTH CERTIFIED TEST DATA AND SUBJECTIVE REASONING. 1.2 EXAMINATION OF BIDDING DOCUMENTS: A. EXAMINE THE BIDDING DOCUMENTS CAREFULLY, NOT LATER THAN SEVEN DAYS PRIOR TO THE DATE OF RECEIPT OF BIDS, WRITTEN REQUEST FOR INTERPRETATIONS OR CORRECTIONS OF ANY PERCEIVED DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS DISCOVERED SHALL BE SUBMITTED TO THE ARCHITECT. ANY INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ARCHITECT. ONLY A WRITTEN INTERPRETATION OR CORRECTION BY ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GIVEN BY ANY OTHER METHOD. IF DISCREPANCIES, AMBIGUITIES, INCONSISTENCIES, OR ERRORS ARE NOT COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, INCLUDE IN THE BID LABOR, MATERIALS, AND METH0°1S OF CONSTRUCTION RESULTING IN HIGHER COST. AFTER AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE DUE TO FAILURE OF MAKING THE WRITTEN REQUESTS AS DESCRIBED ABOVE. B. BE RESPONSIBLE FOR ITS PROMPT DELIVER OF REQUEST. FAILURE TO SO REQUEST CLARIFICATION OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE RESPONSIBILITY OF DOING SO. THE SIGNING OF THE CONTRACT WILL BE CONSIDERED AS IMPLICITLY DENOTING A THROUGH COMPREHENSION OF THE FULL INTENT AND SCOPE OF THE WORKING DRAWINGS AND SPECIFICATIONS. SIGNING OF THE CONTRACT INDICATES AGREEMENT TO ALL OF THE CONDITIONS IN THIS SPECIFICATION. 1.3 MECHANICAL INSTALLATIONS: A. DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT NECESSARILY INDICATE EVERY REQUIRED OFFSET, VALVE, FITTING, ETC. B. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. C. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. WHATEVER IS CALLED FOR IN EITHER IS BINDING AS THOUGH CALLED FOR IN BOTH. D. BEFORE ANY WORK IS INSTALLED, DETERMINE THAT EQUIPMENT WILL PROPERLY FIT THE SPACE; THAT REQUIRED PIPING GRADES CAN BE MAINTAINED AND THAT DUCTWORK CAN BE RUN AS CONTEMPLATED WITHOUT INTERFERENCES BETWEEN SYSTEMS, WITH STRUCTURAL ELEMENTS OR WITH THE WORK OF OTHER TRADES. E. COORDINATE THE INSTALLATION OF MECHANICAL MATERIALS AND EQUIPMENT WITH ALL TRADES. F. COORDINATE THE CUTTING AND PATCHING OF BUILDING COMPONENTS TO ACCOMMODATE THE INSTALLATION OF MECHANICAL EQUIPMENT AND MATERIALS. G. INSTALL MECHANICAL EQUIPMENT TO FACILITATE MAINTENANCE AND REPAIR OR REPLACEMENT OF EQUIPMENT COMPONENTS. AS MUCH AS PRACTICAL, CONNECT EQUIPMENT FOR EASE OF DISCONNECTING, WITH MINIMUM OF INTERFERENCE WITH OTHER INSTALLATIONS. H. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FEES, INSPECTIONS AND PERMITS, 1.4 REMODEL PROJECTS: A. IN AS MUCH AS DESIGN FOR REMODEL AND /OR REHABILITATION REQUIRES THAT CERTAIN ASSUMPTIONS BE MADE REGARDING EXISTING CONDITIONS, AND BECAUSE SOME OF THESE ASSUMPTIONS CANNOT BE VERIFIED WITHOUT DESTROYING OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE BUILDING, THE ENGINEER CANNOT ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL CONSULTING SERVICES HEREIN ENCOMPASS AL CONTINGENCIES. FIELD COORDINATION DURING CONSTRUCTION IS IMPERATIVE. MAKE REASONABLE ALLOWANCES FOR UNSEEN CONDITIONS. B. BE RESPONSIBLE TO FIELD VERIFY EXISTING EQUIPMENT OR DUCTWORK REMAINING TO BE RECONNECTED TO NEW OR EXISTING SYSTEMS. PROVIDE DUCTWORK, PIPING, CONTROLS, DIFFUSERS, ETC., AS REQUIRED TO RESTORE CONTINUITY OF SYSTEMS(S), OR TO MAKE NEW WORK MEET EXISTING CONDITIONS, WHETHER INDICATED OR NOT. C. PROVIDE MECHANICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTING FIXTURES, MECHANICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER. DISPOSE OF ALL REMOVED PIPING, DUCTWORK, ETC. UNLESS NOTED OTHERWISE. D. COORDINATE ALL PENETRATIONS OF THE FLOOR SLAB PRIOR TO COMMENCING WORK. UTILIZE X -RAY AND VISUAL INVESTIGATION OF EXISTING CONDITIONS AS REQUIRED PRIOR TO DRILLING OR CUTTING. 1.5 MECHANICAL SUBMITTALS: A. THE MANUFACTURERS MATERIAL OR EQUIPMENT LISTED IN THE SCHEDULE OR IDENTIFIED BY NAME ON THE DRAWINGS ARE THE TYPES TO BE PROVIDED FOR THE ESTABLISHMENT OF SIZE, CAPACITY, GRADE AND QUALITY. IF ALTERNATES ARE USED IN LIEU OF THE SCHEDULED NAMES, THE COST OF ANY CHANGES IN CONSTRUCTION REQUIRED BY THEIR USE SHALL BE BORNE BY CONTRACTOR. B. BEFORE STARTING WORK, PREPARE AND SUBMIT TO THE ARCHITECT /ENGINEER SHOP DRAWINGS AND DESCRIPTIVE DATA FOR MECHANICAL EQUIPMENT AND MATERIALS REQUIRED FOR THE PROJECT. SUBMIT ON: CABINET UNIT HEATERS, 1.6 RECORD DOCUMENTS: A. CONTRACTOR SHALL KEEP A COMPLETE SET OF RED -LINED a RECORD DOCUMENT PRINTS IN CUSTODY DURING ENTIRE PERIOD OF CONSTRUCTION AT THE CONSTRUCTION SITE. ONE (1) SET OF RECORD DOCUMENTS SHALL BE PROVIDED TO THE ENGINEER INDICATING FINAL PROJECT CONDITIONS AFTER COMPLETION OF WORK, 1.7 OPERATION AND MAINTENANCE DATA: A. CONTRACTOR SHALL PREPARE TWO (2) SETS OF MAINTENANCE MANUALS AND SHALL INSTRUCT OWNER ON OPERATION OF SYSTEMS. MAINTENANCE MANUALS SHALL INCLUDE ALL MECHANICAL WARRANTIES. B. THE TESTING AND BALANCING REPORT SHALL BE SUBMITTED AND RECEIVED BY THE ENGINEER AT LEAST FIFTEEN CALENDAR DAYS PRIOR TO THE CONTRACTOR'S REQUEST FOR FINAL OBSERVATION TIME FRAME REQUIREMENTS, AND SHALL BE INCLUDED IN THE 0 & M MANUAL. 1.8 WARRANTY: A. THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY LICENSEE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WOK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP, END OF SECTION 1.3 PIPING TESTS: A. GENERAL: PROVIDE TEMPORARY EQUIPMENT FOR TESTING, INCLUDING PUMP AND GAGES, TEST PIPING SYSTEM BEFORE INSULATION IS INSTALLED WHEREVER FEASIBLE, AND REMOVE CONTROL DEVICES BEFORE TESTING. TEST EACH NATURAL SECTION OF EACH PIPING SYSTEM INDEPENDENTLY BUT DO NOT USE PIPING SYSTEM VALVES TO ISOLATE SECTIONS WHERE TEST PRESSURE EXCEEDS VALVE PRESSURE RATING. FILL EACH SECTION WITH WATER AND PRESSURIZE FOR INDICATED PRESSURE AND TIME. B. TEST ALL PIPING SYSTEMS AS SPECIFIED. CORRECT LEAKS BY REMAKING JOINTS. REMOVE EQUIPMENT NOT ABLE TO WITHSTAND TEST PROCEDURE DURING TEST. C. SYSTEM TESTS 1. HYDROSTATIC TEST: THE TEST SHALL BE ACCOMPLISHED BY HAND PUMPING THE SYSTEM TO THE SPECIFIED WATER PRESSURE, AND MAINTAINING THAT PRESSURE UNTIL THE ENTIRE SYSTEM HAS BEEN INSPECTED FOR LEAKS, BUT IN NO CASE FOR A TIME PERIOD OF LESS THAN FOUR HOURS. a. HYDRONIC AND DOMESTIC WATER SYSTEMS: 100 PSIG TEST PRESSURE. b. WASTE, DRAIN AND VENT SYSTEMS: WATER TEST WITH SYSTEM FILLED TO HIGHEST POINT OF OVERFLOW. MINIMUM 10 FOOT HEAD. r• • SECTION 15100 VALVES 1.1 GENERAL: A. ALL MECHANICAL COMPONENTS SHALL BE PROVIDED WITH VALVES AND UNIONS FOR SERVICES AND REMOVAL. B. ALL VALVES SHALL COMPLY WITH MSS SP -92, MSS VALVE USER GUIDE. C. PROVIDE STEM EXTENSIONS FOR INSULATED SYSTEMS, 1.2 PRODUCTS: A. BALL VALVES 2" AND SMALLER: ANSI B16.34, CLASS 150 WSP, 600 WOG, RATED FOR 150 PSI AT 3500F, TWO PIECE END ENTRY BODY STYLE, BRONZE BODY CONFORMING TO ASTM B584, SINGLE FULL PORT, STAINLESS STEEL BALL AND STEM OF ASTM A276 TYPE 316, 15% GLASS REINFORCED PTFE SEATS, PTFE PACKING AND BLOW OUT PROOF STEM, VINYL COATED STEEL HANDLE. MANUFACTURERS: CONBRACO (APOLLO), CRANE, STOCKHAM, NIBCO. 1.3 INSTALLATION: A. PROVIDE VALVES WHERE INDICATED ON PLANS AND AS NECESSARY FOR PROPER SYSTEM OPERATION AND COMPONENT ISOLATION, INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. END OF SECTION SECTION 15140 SUPPORTS, ANCHORS AND SEALS 1.1 GENERAL A. ALL PIPE HANGERS SHALL BE THREADED ROD WITH CLEVIS OR TRAPEZE SUPPORTS. 1. INSULATED PIPING: COMPLY WITH THE FOLLOWING INSTALLATION REQUIREMENTS. 2. SHIELDS: PROVIDE PROTECTIVE SHEET SHIELDS, MSS TYPE 40 ON COLD PIPING 2" AND LESS. SHIELDS SHALL SPAN AN ARC OF 180 DEGREES AND SHALL BE MINIMUM 8" LONG. B. ALL DUCT HANGERS SHALL BE SHEET METAL STRAP OR ANGLE IRON IN COMPLIANCE WITH SMACNA GUIDELINES. END OF SECTION SECTION 15250 INSULATION 1.1 PIPING INSULATION A. FIBERGLASS PIPING INSULATION: ASTM C547, CLASS 1, "K" FACTOR SHALL BE MAXIMUM 0.24 AT 750F. AND ALL PURPOSE JACKETING, ASTM C921 UNLESS SPECIFIED OTHERWISE AND HAVE RATINGS OF 25 OR LESS FLAME SPREAD AND 50 OR LESS SMOKE DEVELOPMENT. B. PIPING INSULATION APPLICATION 1. HEATING WATER PIPING: 1 -112" THICK. 1.2 DUCTWORK INSULATION A. FLEXIBLE FIBERGLASS DUCTWORK INSULATION: ASTM 0553, TYPE 1, 3/4 LBS PER CU. FT. DENSITY. "K" VALUE SHALL BE MAXIMUM 0.31 AT 75?F MEAN TEMPERATURE, 250DEG F TEMPERATURE LIMIT, VAPOR TRANSMISSION RATING SHALL NOT EXCEED 0.02 PERMS, FACING OF .7 MIL FOIL REINFORCED WITH GLAS MESH AND LAMINATED TO 40 L.B. KRAFT. B. DUCTWORK INSULATION APPLICATION: 1. SUPPLY DUCTS: 1-1/2" FLEXIBLE FIBERGLASS. 2. DO NOT INSULATE DUCTS INDICATED TO BE INTERNALLY LINED. END OF SECTION SECTION 15830 0 TERMINAL UNITS 1.1 GENERAL A. PROVIDE TERMINAL UNITS BY THE FOLLOWING MANUFACTURER: 1. TRANE 1.2 PRODUCTS A. CABINET UNIT HEATERS: 1. GENERAL: PROVIDE HOT WATER CABINET HEATERS HAVING CABINET SIZES AND IN LOCATIONS AS INDICATED, AND OF CAPACITIES, STYLE, AND HAVING ACCESSORIES AS SCHEDULED. INCLUDE IN BASIC UNIT CHASSIS, COIL, FANBOARD, FAN WHEELS, HOUSINGS, MOTOR, AND INSULATION. 2. CHASSIS: GALVANIZED STEEL WRAPOAROUND STRUCTURAL FRAME WITH EDGES FLANGED. 3. INSULATION: FACED, HEAVY DENSITY GLASS FIBER, 4. CABINET: 160GA REMOVABLE FRONT PANEL,180GA TOP AND SIDE PANELS. INSULATE FRONT PANEL OVER ENTIRE COIL SECTION. PROVIDE ACCESS DOOR ON COIL CONNECTION SIDE. CLEAN CABINET PARTS, BONDERIZE, PHOSPHATIZE, AND FLOW DCOAT. 5. WATER COILS: CONSTRUCT OF 5/8" SEAMLESS COPPER TUBES MECHANICALLY BONDED TO CONFIGURATED ALUMINUM FINS. DESIGN FOR 300 PSI AND LEAK TEST AT 300 PSI UNDER WATER. PROVIDE SAME END CONNECTIONS FOR SUPPLY AND RETURN. 6. FANS: PROVIDE CENTRIFUGAL, FORWARD CURVED DOUBLE WIDTH FAN WHEELS CONSTRUCTED OF NONOCORROSIVE, MOLDED, FIBERGLASSO REINFORCED THERMOOPLASTIC MATERIAL. CONSTRUCT FAN SCROLLS OF GALVANIZED STEEL. 7. MOTORS: PROVIDE SHADED POLE MOTORS WITH INTEGRAL THERMAL OVEROLOAD PROTECTION, AND MOTOR CORDS FOR PLUGOIN TO JUNCTION BOX IN UNIT. 8. FILTERS: PROVIDE 1" THICK THROWAWAY TYPE FILTERS IN FIBERBOARD FRAMES. A. ALL DUCTWORK SHALL BE GALVANIZED STEEL, LOCKFORMING QUALITY, FABRICATED IN ACCORDANCE WITH THE 1955 SMACNA AND DUCT CONSTRUCTION STANDARDS. B. ROUND DUCT: SPIRAL SEAM, GALVANIZED STEEL. DIE STAMPED OR 5 GORE ELBOWS. "SNAP - LOCK", LONGITUDINAL SEAM DUCT, OR ADJUSTABLE FITTINGS ARE ACCEPTABLE ON INDIVIDUAL GRILLE/DIFFUSER RUNOUTS ONLY. C. INSULATED FLEXDUCT SHALL BE USED FROM SUPPLY DUCT TO AIR DIFFUSERS. DIFFUSERS ABOVE LAY -IN CEILINGS ONLY. ABOVE HARD CEILING SHALL BE HARD DUCTED. 1. ALL FLEXIBLE DUCT SHALL BE RATED FOR SOUND ATTENUATION a. FLEXMASTER TYPE 8M 2. FLEXIBLE DUCT SHALL NOT EXCEED 6' -0" IN LENGTH. D. PROVIDE SPIN -IN FITTINGS WITH LOCKING DAMPER BEARINGS AT ALL FLEXIBLE OR ROUND SHEET METAL DUCT TAKE -OFFS. E. PROVIDE WHERE INDICATED, 1" THICK, 1 -112" LB DENSITY, BLACK MATTE COATED, FIBERGLASS DUCT LINER MEETING ASTM C1071 TYPE 1, UL 181, NFPA 90A AND 90B AND TIMA (AHC -101) WITH MINIMUM NRC (NOISE REDUCTION COEFFICIENT) OF 0.70 AS TESTED PER ASTM C 4323 USING AN "A" MOUNTING WITH MINIMUM "K" FACTOR OF 0.25. INSTALL IN ACCORDANCE WITH SMACNA "DUCT CONSTRUCTION STANDARDS ". PROVIDE SHEET METAL NOSING WHEREVER LINER BEGINS OR ENDS. 1. LINE ALL RECTANGULAR SUPPLY AND RETURN DUCTS. 1.2 DUCT SEALING A, SEAL ALL LONGITUDINAL AND TRANSVERSE JOINTS WITH NON - HARDENING, NON - MIGRATING MASTIC OR LIQUID ELASTIC SEALANT OF A TYPE RECOMMENDED BY THE MANUFACTURER FOR SEALING JOINTS AND SEAMS IN SHEET METAL DUCTWORK. COVER ALL FIELD JOINTS AROUND SPIN -IN FITTINGS AND FASTENING SCREWS WITH MASTIC. END OF SECTION SECTION 15060 PIPE AND FITTINGS 1.1 GENERAL: A. HEATING, COOLING AND DRAIN PIPING SHALL BE BLACK STEEL PIPE, ASTM A53, SCHEDULE 40 OR HARD DRAWN TEMPER COPPER TUBING, ASTM B88, TYPE L. 1.2 PIPING INSTALLATION: A. INSTALL PIPES AND PIPE FITTINGS IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES WHICH WILL ACHIEVE PERMANENTLYOLEAKPROOF PIPING SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED SERVICE WITHOUT PIPING FAILURE. INSTALL EACH RUN WITH MINIMUM JOINTS AND COUPLINGS, BUT WITH ADEQUATE AND ACCESSIBLE UNIONS FOR DISASSEMBLY AND MAINTENANCE /REPLACEMENT OF VALVES AND EQUIPMENT. 1. USE FITTINGS FOR ALL CHANGES IN DIRECTION AND ALL BRANCH CONNECTIONS. 2. INSTALL PIPING AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE NOT PERMITTED, UNLESS EXPRESSLY INDICATED. Na r • # SECTION 15890 DUCTWORK 1.1 GENERAL SECTION 15931 AIR DEVICES 1.1 GENERAL A. AIR DEVICES SHALL BE PROVIDED TO DISTRIBUTE SUPPLY AND RETURN AIR WITHIN INDIVIDUAL AREAS OF THE BUILDING. THEY SHALL INCLUDE REGISTERS, GRILLES, AND DIFFUSERS, AS SCHEDULED. END OF SECTION SECTION 15975 CONTROLS 1.1 GENERAL A. PROVIDE CONTROL SYSTEMS CONSISTING OF THERMOSTATS, CONTROL VALVES, OPERATORS, INDICATING DEVICES, INTERFACE EQUIPMENT, AND OTHER APPARATUS REQUIRED TO OPERATED MECHANICAL SYSTEM AND TO PERFORM FUNCTIONS SPECIFIED. B. PROVIDE NECESSARY MATERIALS AND FIELD WORK NECESSARY TO CONNECT CONTROL COMPONENTS FACTORY SUPPLIED AS PART OF EQUIPMENT CONTROLLED, UNLESS SPECIFIED OTHERWISE. END OF SECTION D SECTION 15991 TESTING AND BALANCING 1.1 DESCRIPTION OF WORK A. THIS SECTION COVERS TESTING AND BALANCING OF ENVIRONMENTAL SYSTEMS INCLUDING BUT NOT LIMITED TO AIR DISTRIBUTION SYSTEMS, HYDRONIC DISTRIBUTION SYSTEMS, AND THE EQUIPMENT AND APPARATUS CONNECTED THERETO. 1.2 QUALIFICATIONS OF CONTRACTOR A. THE CONTRACTOR SHALL PROCURE THE SERVICES OF AN AABC OR NEBB CERTIFIED, INDEPENDENT TESTING AND BALANCING AGENCY SPECIALIZING IN THE TESTING, ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS TO PERFORM THE ABOVE MENTIONED WORK, 1.3 CODES AND STANDARDS A, NEBB: "PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS." B. ASHRAE: ASHRAE HANDBOOK, 1987 SYSTEMS VOLUME, CHAPTER 57, TESTING, ADJUSTING, AND BALANCING, 1.4 PROJECT CONDITIONS A. AIR AND WATER TESTING AND BALANCING SHALL NOT BEGIN UNTIL THE SYSTEM HAS BEEN COMPLETED AND IS IN FULL WORKING ORDER. B. PUT ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS AND EQUIPMENT INTO FULL OPERATION AND CONTINUE OPERATION OF SAME DURING EACH WORKING DAY OF TESTING AND BALANCING. 1.5 TEMPERATURE CONTROLS A. OPERATE ALL TEMPERATURE CONTROL SYSTEMS WITH THE TEMPERATURE CONTROL CONTRACTOR'S REPRESENTATIVE FOR PROPER SEQUENCE OF OPERATION AND CALIBRATION. REPORT IN WRITING ANY DEFIDCIENCIES TO THE ENGINEER IMMEDIATELY. 1.6 REQUIREMENTS OF WORK A. BALANCING PROCEDURE SHALL BE IN ACCORDANCE WITH NEBB OR AABC GUIDELINES FOR PROPORTIONAL BALANCE. SUBMIT REPORT ON STANDARD NEVV FORMS OR SUBMIT FORMS FOR REVIEW PRIOR TO BALANCING. MEASUREMENTS SHALL INCLUDE ALL MOTOR AMPERAGE AND VOLTAGE READINGS; MOTOR AND FAN RPMS; STATIC PRESSURE AT INLET AND OUTLET OF ALL PACKAGED EQUIPMENT, FANS, COILS, AND FILTERS; PITOT TUBE MEASUREMENT OF SUPPLY, EXHAUST, RETURN, AND OUTSIDE AIR MAIN DUCTS; AIR INLET AND OUTLETS; WATER FLOW AT ALL FLOW MEASUREMENT STATIONS; INLET AND OUTLET PRESSURE AT PUMPS WITH FLOW CALCULATED FROM THE PUMP CURVE; WATER FLOW, AND PRESSURE DROP AT ALL COILS. B. PROVIDE BELTS AND SHEAVES AS REQUIRED FOR DRIVE CHANGES TO ADJUST FAN SPEED. C. ADJUST FLOWS TO WITHIN 10% OF REQUIRED QUANTITY. IF ACTUAL QUANTITY IS LESS THAN 90 %, INVESTIGATE CAUSE, ATTEMPT TO RECTIFY AND NOTIFY ENGINEER. SUBMITTAL OF BALANCE REPORT WITH LESS THAN REQUIRED FLOWS WITHOUT EXPLANATION IS CAUSE FOR REJECTION OF REPORT. 1.7 REPORT OF WORK A. THE TESTING & BALANCING CONTRACTOR SHALL SUBMIT SIX (6) BOUND COPIES OF THE FINAL TESTING AND BALANCING REPORT AT LEAST 15 CALENDAR DAYS PRIOR TO THE MECHANICAL CONTRACTOR'S REQUEST FOR FINAL OBSERVATION. ALL DATA SHALL BE RECORDED ON APPLICABLE REPORTING FORMS. THE REPORT SHALL INCLUDE ALL OPERATING DATA, A LIST OF ALL EQUIPMENT USED IN THE TESTING AND BALANCING WORK, AND SHALL BE SIGNED BY THE SUPERVISING ENGINEER AND AFFIXED WITH HIS CERTIFICAOTION SEAL. FINAL ACCEPTANCE OF THIS PROJECT WILL NOT TAKE PLACE UNTIL A SATISFACTORY REPORT IS RECEIVED. 1.8 GUARANTEE OF WORK A, THE TESTING & BALANCING CONTRACTOR SHALL GUARANTEE THE ACCURACY OF THE TESTS AND BALANCE FOR A PERIOD OF 90 DAYS FROM DATE OF FINAL ACCEPTANCE OF THE TEST AND BALANCE REPORT. DURING THIS PERIOD, THE TESTING & BALANCING CONTRACTOR SHALL MAKE PERSONNEL AVAILABLE AT NO COST TO THE OWNER TO CORRECT DEFICIENCIES THAT MAY BECOME APPARENT IN THE SYSTEM BALANCE. END OF SECTION r� CWS/ HWS/ C O N D D IN AIR DEVICE S HEDULE DESIG. MFR. MODEL TYPE FRAME MATERIAL FINISH DAMPER FACE SIZE REMARKS TYPE A TITUS LINEAR SLOT ML -39 SURFACE 2A ALUMINUM WHITE NOTE 1 NOTE 2 B TITUS LOUVERED FACE TMS LAY -IN STEEL WHITE N/A 24x24 C TITUS PERFORATED PAR LAY -IN STEEL WHITE N/A 24x12 RETURN D TITUS PERFORATED RETURN PAR SURFACE STEEL WHITE N/A 24x24 NOTES: 1. PATTERN CONTROLLER SHALL ALSO SERVE AS DAMPER. 2.4' -6" LONG, (1)1" SLOT. 711312007 10:54 PAArrabelle\ 2007 -113 Activities Desk\CadlMech\Mschedulesi[M- 2007- 113.xlsIS932 -1 Air Dvc rr rrrrr. 7 r� i Ir U `L i t ii i i LJ a 4 M Z S G M 0 0 R C z `_' K a F r (_:.r~��rm, Rt. NIA E �VSSQ(lkns, Co. C'C)h5F1tTItiC ". rFCFFANFCA :IELR - _- tTCAF. k".+ GIR IFERS 16.O Diver Sireot. Su to Two . Laxo:vc d. 2� K215 3132 3QJ242.6200. Fax 0 CravCatornama,COm.wmv:.a!or ma.com A2 # 1 07130107 PERMIT 07/13/07 ISSUED FOR: DATE: _ , t ♦y N i 1 `11.� t % .+ 1: IVA THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY ` IORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDIT'ONS SHOWN BY THESE DRAWINGS, I ��I Cator, Ruma & Assoc. FILENAME: P: \ARRABELLE \2007 -113 ACTIVITIES DESK \CAD \MECH \P- HV1.DWG - M101 PLOT DATE: 09/06/2007 0 1:32pm REV: 09/06/2007 CAD: HYoder XREF. clgl.dwg bgl.dwg hvl.dwg tb.dwg Cator, O il 1 lill'' k OR 1. MAKE ALL FINAL ELECTRICAL CONNECTIONS TO EQUIPMENT REQUIRING ELECTRICAL CONNECTION. THIS SHALL INCLUDE BUT NOT BE LIMITED TO ALL MECHANICAL AND OTHER EQUIPMENT INCLUDED IN THIS PROJECT. 2. PROVIDE FUSES SIZED PER EQUIPMENT MANUFACTURER'S REQUIREMENTS. 3. DISCONNECT SWITCH LOCATIONS ARE SHOWN DIAGRAMMATICALLY AND SHALL BE INSTALLED IN ACCESSIBLE LOCATIONS TO SUiT EQUIPMENT AND SPACE. DISCONNECT SWITCHES SHALL BE WITHIN SIGHT OF THE EQUIPMENT THEY SERVE AND MOUNTED AT 6' -3 ", MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE REQUIREMENTS. 4. RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNTER ARE TO BE MOUNTED HORIZONTALLY 6" ABOVE COUNTER. 5. PROVIDE 4' SQUARE OUTLET BOX, SINGLE GANG MUD RING AND BLANK SINGLE GANG COVER PLATE FOR ALL INDIVIDUAL TELEPHONE, DATA, COMBINATION TELE /DATA AND TELEVISION OUTLETS. PROVIDE 3 /4 "C. FROM INDIVIDUAL TELEPHONE, DATA, COMBINATION TELE /DATA AND TELEVISION OUTLETS TO HEAD END EQUIPMENT BACKBOARD. PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. 6. COORDINATE AND VERIFY EXACT MOUNTING LOCATIONS OF WALL AND FLOOR DEVICES WITH ARCHITECTURAL ELEVATIONS, AND ANY FURNITURE OR SPECIALTY EQUIPMENT SUPPLIER DRAWINGS PRIOR TO ROUGH -IN. 7. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN. 8. NO RECEPTACLES SHALL BE MOUNTED BELOW +18" AFF. 9. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SIX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. BRANCH CIRCUITS ARE 2 #12, #12G, 3/4 "C UNLESS OTHERWISE INDICATED. 10. DEMO ALL EXISTING CORE /SHELL WIRING DEVICES UNLESS EQUIPMENT IS SHOWN AS EXISTING TO REMAIN. 1. REFER TO ARCHITECTURAL ELEVATIONS AND REFLECTED CEILING PLANS FOR EXACT MOUNTING LOCATIONS OF DEVICES AND LUMINAIRES. 2. COORDINATE LUMINAIRE LOCATIONS WITH MECHANICAL PIPING, DUCTWORK, ETC., TO AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINATION REQUIREMENTS. 3 • DEMO CORE /SHELL LIGHTING AND BRANCH CIRCUITING BACK TO PANELBOARD. 4. CIRCUITS MAY BE COMBINED INTO HOMERUNS OF UP TO SiX (6) CURRENT CARRYING CONDUCTORS, INCLUDING NEUTRALS, UNLESS OTHERWISE INDICATED. J I r r r r r r r r r r r r 1. WORK INCLUDED IN THE CONIT= it CT IS DENOTED IN BOLD. EXISTING CONDITIONS TO REMAIN ARE DENOTED LIGHTLY. 2. PROTECT STRUCTURE AND OWNER EQUIPMENT FROM DAMAGE. IMMEDIATELY REPLACE OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONTRACTOR WHETHER EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN AUTHORIZATION FROM THE OWNER INDICATED OTHERWISE. PREPARE LISTING OF ALL EXISTING DAMAGED ITEMS AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. 3. INSTALL CONDUIT CONCEALED IN FINISHED AREAS. DO NOT ROUTE CONDUIT WITHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS SPECIFICALLY NOTED OTHERWISE AND WRITTEN APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 4. FIRE SEAL ALL FIRE RATED WALL AND FLOOR PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALLS. 5. COORDINATE EXACT REQUIREMENTS AND LOCATIONS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN AND ORDERING MATERIALS OR EQUIPMENT. 6. A DETAILED WRITTEN METHOD OF PROCEDURE IS REQUIRED WHEN A CONSTRUCTION AC11VITY OR AN OUTAGE AFFECTS THE SAFETY OF OCCUPANTS, TELEPHONE /DATA /FIRE ALARM EQUIPMENT OR COMPONENTS OF ANY SYSTEM WHICH SUPPORTS THIS EQUIPMENT OR ESSENTIALLY AFFECTS THE BUILDING MANAGEMENT, OPERATIONS OR SECURITY. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. • j> CIRCUIT NIGHTUGHT /EM LIGHT AND EXIT LIGHT AHEAD OF SWITCHLEG. <: > SWITCHED EMERGENCY LIGHT. REFER TO WIRING DIAGRAM ON E1.O. '�✓ LUTRON DIVA SERIES SWITCHES: PADDLE SWITCH ( "a ", "c ", "e " }, #CAIPSH, MAGNETIC LOW VOLTAGE PRESET PADDLE DIMMER ( "b), #DVLV -600, ELECTRONIC LOW VOLTAGE PRESET PADDLE DIMMER ( "d "), #DVELV -300P. SWITCHES SHALL NOT BE GANGED. FACEPLATE AND SWITCH TO BE WHITE. �4 PROVIDE 3- CHANNEL ASTRONOMICAL TIME CLOCK # 7200ZL WITH REMOTE SWITCH OVERRIDE. CIRCUIT TO NE3 -9. PROVIDE 120V MASTER OVERRIDE SWITCH AT CASH COUNT DOORWAY FOR EACH CHANNEL UTILIZED. PROVIDE DUAL TECHNOLOGY OCCUPANCY SENSOR WITH OVERRIDE SWITCH - MANUFACTURER AND MODEL TO MATCH BASE BUILDING. COORDINATE WITH ENGINEER PRIOR TO ORDERING. < �6 > PROVIDE 2' X 2' PLYWOOD BACKBOARD MOUNTED AT 7' -0" ABOVE FINISHED FLOOR, PAINTED WHITE, FOR LOW VOLTAGE SYSTEMS EQUIPMENT. PROVIDE 2 "C WITH PULLCORD TO BASE BUILDING TELECOM ROOM "TRG2A" - SEE KEY PLAN, THIS SHEET. ROUTE CONDUIT THROUGH BASE BUILDING TELECOM ROOMS. �>7 RELOCATED PANELBOARD. MOUNT FLUSH IN WALL. EXTEND FEEDER CONDUIT AS REQUIRED. 8` COORDINATE MOUNTING HEIGHT OF WIRING DEVICE WITH TV SCREEN. COORDINATE CABLING REQT WITH OWNER. < �9 > SECURITY CAMERA - FLEXIDOME -XT +COLOR NTSC540WL. COORDINATE CABLING REQUIREMENTS WITH OWNER (MOUNTAIN OPS). PROVIDE HEAD END EQUIPMENT BOSCH VDC- 455VO3 -20S AND 12VDC /24VAC 60HZ 2.6- 6MMF1.4 V/F WHT SMB - LOCATiON TBD. PROVIDE 120V BRANCH CIRCUIT TO "NE3 ". CIRCUIT TO PANEL "NE3" w r 1 NE3 -6 T 9 -. I LEVEL G2 - T'RG2A LOCATION SCALE: 1/16"=l'-O" ST FLR ABOVE) AREA "L LINE AREA A GENERAL SCOPE THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK. PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T &B FLAMESAFE OR OTHER APPROVED METHOD. CONDUCTORS AND TERMINATIONS SITE EXAMINATION THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. STANDARDS EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE TO EACH INDIVIDUAL UNIT OR ASSEMBLY. CODES ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT BETWEEN THE DRAWINGS /SPECIFICATIONS AND THE CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD VaITHQUT ANY EXTRA COST TO LICENSEE. PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY LICENSEE AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED iN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. COORDINATION THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. TESTING ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. TEMPORARY POWER THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL WIRING FOR CONSTRUCTION. THE TEMPORARY SERVICE SHALL BE A MINIMUM OF 60 AMPS, SINGLE PHASE, THREE WIRE, 120/208 VOLTS FUSED AT MAIN DISCONNECT. ALL RECEPTACLES ON THIS TEMPORARY SERVICE SHALL BE PROTECTED BY A GFi BREAKER. MECHANICAL EQUIPMENT ALL FINAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. EXISTING SYSTEMS DEMOLITION THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WiLL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. POWER OUTAGES THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE, UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:OOPM AND 5:OOAM. BASIC MATERIALS AND METHODS MATERIALS PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED AND LABELED, OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE LOCAL JURISDICTION, FOR THE PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION TO MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. CUTTING AND FITTING PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THiS SECTION. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE LICENSEE AND LANDLORD. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES, AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT AND COPPER CONDUCTORS, OR MC CABLE FOR MECHANICAL EQUIPMENT, LIGH NG A T1 AND POWER, CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORROSION- RESISTANT FITTINGS. SCHEDULE 40 PVC IS ACCEPTABLE WHERE PERMITTED BY CODE AND FOR UNDERGROUND RUNS OR CONCRETE ENCASEMENT WHERE NOT EXPOSED TO PHYSICAL DAMAGE. THE MINIMUM SIZE OF CONDUIT SHALL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT RUNS CONCEALED IN CONCRETE SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED, CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. RIGID CONDUIT SHALL BE HOT DIPPED GALVANIZED. BRANCH CIRCUIT WORK CHASED INTO EXISTING CONSTRUCTION FOR CONCEALMENT UNDER PATCHED FINISHES SHALL BE INSTALLED IN RIGID CONDUIT, OR EMT. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRING. CONDUCTORS CONDUCTORS SHALL BE COPPER, INSULATED FOR 60OV. TYPE THWN /THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUIT, WIRING, AND SAFETY SWITCHES FOR ALL MOTORS, AND OTHER ELECTRICAL EQUIPMENT , EVEN THOUGH THE MOTORS AND ELECTRICAL EQUIPMENT MAY BE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS REQUIRED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. THE ELECTRICAL EQUIPMENT MAY INCLUDE BUT NOT BE LIMITED TO SUCH ITEMS AS GRILLE MOTORS AND INTERLOCKS, STOREFRONT AND INTERIOR SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS AND STEREO SYSTEMS. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE SUPPLYING THE EQUIPMENT BEFORE INSTALLING THE CONDUIT OR OUTLETS. SWITCHES AND RECEPTACLES SWITCHES SLATER NO. 2770 -WH OR APPROVED EQUAL WITH MATCHING COVERPLATES. INCANDESCENT DIMMERS LUTRON NOVA T SERIES WITH MATCHING COVERPLATES, 1500 WATT MAXIMUM, AS REQUIRED FOR FIXTURE QUANTITIES SHOWN ON THE LIGHTING PLAN. RECEPTACLES LUTRON NOVA T SERIES NTH MATCHING COVERPLATES, 1500 WATT MAXIMUM, AS REQUIRED FOR FIXTURE QUANTITIES SHOWN ON THE LIGHTING PLAN. SLATER NO. 6242SWH OR APPROVED EQUAL WITH MATCHING COVERPLATES. INSTALL RECEPTACLES WiTH GROUND PiN UP AT +15" UNLESS OTHERWISE NOTED. AT BACKBAR MOUNT AT +10" ABOVE COUNTERTOP UNLESS OTHERWISE NOTED, PROVIDE GFCI TYPE WHERE INDICATED. OCCUPANCY SENSORS WATTSTOPPER #WA- 100 -WHITE FOR USE IN ALL TOILET ROOMS. DISCONNECTS AND FUSED SWITCHES FUSED SWITCHES HEAVY DUTY TYPE, HORSEPOWER RATED WiTH INTERLOCKING COVER. NEMA 1 TYPICAL. OUTDOOR AND WET LOCATION SWITCHES SHAT L BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600 AMPERES OR LESS SHALL BE UL CLASS RK1 DUAL - ELEMENT, TIME- DELAY, CURRENT LIMITING FUSES. FUSES iN CIRCUITS RATED AT 601 AMPERES OR LARGER SHALL BE UL CLASS L TIME - DELAY, CURRENT LIMITING FUSES. NAMEPLATES PROVIDE PERMANENT NAMEPLATE LABELING ON ALL DISCONNECTS. INCLUDE LOAD SERVED, VOLTAGE, PHASE, HORSEPOWER, FUSE SIZE, AND TYPE. MOUNTING MOUNT INDEPENDENT OF THE MECHANICAL UNIT HOUSING UNLESS SPECIFICALLY ACCEPTED BY THE LOCAL CODE AUTHORITY. PROVIDE UNISTRUT SUPPORT CHANNELS MOUNTED IN COORDINATION WITH ROOF PENETRATION AND PATCHING WORK. COORDINATE WITH GENERAL CONTRACTOR. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS AS PROVIDING GROUND CONTINUITY. PANELBOARDS PROVIDE BRANCH CIRCUIT PANELBOARD(S) AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. PANELBOARDS SHALL HAVE PLUG -IN BREAKERS AND MAIN LUGS ONLY OR MAIN BREAKERS AS REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 TYPE HOUSING AS MANUFACTURED BY "SQUARE D ", "ITE ", OR EQUAL. ENCLOSURE(S) SHALL BE COMPLETE WiTH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED DIRECTORY UNDER PLASTIC COVER IN EACH PANEL DOOR, ALL MULTIPLE POLE BREAKERS SHALL HAVE A COMMON TRIP HANDLE. LIGHTING PROVIDE A NEW LIGHTING SYSTEM COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND UL LISTING REQUIREMENTS, CLEAN ALL FIXTURES AT TIME OF JOB COMPLETION UTILIZING MANUFACTURERS APPROVED OR RECOMMENDED CLEANING SOLUTIONS. ALL FIXTURES AND LAMPS ARE SELECTED AND PROVIDED BY STARBUCKS AS SCHEDULED ON SHEET SC.2 UNLESS NOTED OTHERWISE. TELEPHONE SYSTEM TELEPHONE WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -IN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. SECURITY SYSTEM NOTES SECURITY WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -IN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. POS / DATA LINE NOTES P.O.S. WIRING AND SYSTEM PROVIDED BY LICENSEE. VERIFY SYSTEM REQUIREMENTS AND ROUGH -iN LOCATIONS WITH LICENSEE PRIOR TO START OF CONSTRUCTION. t Aj i �I ti i i t I N U z � a 0 Y r x x C O W o � 4 � O o, W � a ul CArm Rul'vlA 6 Ass ocim'Es, Co. CONSIILTINNG Ps,S:C.HAN7C A:Jf[EC-- lUC:AL EWGP F.ER.i 1650 ,7s.'VSx $!Met r SU to Two . LWwvo.+d. 0O 8, 5162 3"1_24200 Y Faf 303f23a.s,0 Ctd:[}"Cii?6r"JXfl$.C6`Ii • 1YiN4,:9.:P"li,lYid.:4i1 �oiMT���i 07/30/07 07/13/07 DATE: YY f� Y 4't C7� 7 1 � THESE DRAWINGS AND SPECIFICATIONS ANh THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT" WITH THESE DRAWINGS OR SPECIFICATIC SHALT. CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALE. HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITiONS SHOWN BY THESE DRAWINGS. FIRST FLOOR LIGHTING AND POWER PLANS E2.1 Catar, Ruma &Assoc. FILENAME: P: �ARRABELLE \2007 -113 ACTIVITIES DESK \CAD \ELEC�P- ELECI.DWG _ E2.1 PLOT: O9 f 06 f 2007 � 10: 33am REV: 09/06 /2007 CAD: HYader XREF: bgl,dwg clgl.dwg pwrl.dwg tb.dwg bg- g2.dwg a- fp- g2.dwg S- GRID- MATCHLINE.dwg A- CL- G2.dwg A- CR- G2.dwg G2- RAMP.dwg s- grid- garage.dwg MATERIALS KEY GRAPHICS KEY SYSTEM NOTES: PROJECT DATA: DRAWING INDEX: ELEVATION SYMBOL WALL TYPES I CLIENT: FIRE ALARM: SHEET NO. DESCRIPTION SCALE IN SECTION UNLESS OTHERWISE NOTED III - III -I1 EARTH POROUS FILL /GRAVEL CAST IN PLACE CONCRETE PRE -CAST CONCRETE t A5.1 t Ab.t B2 A6.4 BUILDING SECTION WALL SECTION SECTION DETAIL TYPE DESCRIPTION WALL TYPE DIAGRAM VAIL RESORTS DEVELOPMENT COMPANY i SHANER LIFE SAFETY P.O. BOX 1073 137 BENCHMARK ROAD FRISCO, CO 80443 AVON, COLORADO PHONE 970 - 409 -9082 (970) 845 -2355 FAX (970) 845 -2358 FAX 720 - 294 -9849 I i ARCHITECT: FIRE PROTECTION: � MELICK ASSOCIATES, INC. CHIP MELICK I ALLSTATE FIRE PROTECTION, INC. 355 SOUTH TELLER STREET, SUITE 370 6045 EAST 76TH AVEUE #12 ARCHITECTURAL - A0.1 A2.1 A7.1 A8.1 A10.1 MECHANICAL COVER SHEET PROJECT NO SCALE INFORMATION /INDEX OUTLINE NO SCALE FLOOR PLAN / REFLECTED CEILING PLANS 1 /2 " = l' -0" INTERIOR ELEVATIONS 1/2 = 1' -0 "' MILLWORK DETAILS / PLAN DETAILS VARIES SCHEDULES VARIES r. F� 1 LAYER OF 5/8 GYP. BD. EACH SIDE Wt OF 3 5/8" METAL STUDS @16" O.C. � - NOT USED ` LIGHT WEIGHT CONCRETE e BRICK FACE CONCRETE MASONRY UNIT STRUCTURAL TILE STEEL ALUMINUM BRASS /BRONZE FINISH WOOD WOOD SHIM ROUGH WOOD /BLOCKING A D 1 A7.1 B c _GROU FLOOR ' -O° �` EL - too CE) D2oi �� W2t31 0 CD PT PT1 INTERIOR ELEVATION SYMBOL FLOOR ELEVATION SYMBOL CEILING HEIGHT KEY WINDOW FRAME KEY WALL TYPE KEY DOOR NUMBER KEY WINDOW NUMBER KEY LOUVER LABEL KEY KEYNOTE TOILET ACCESSORY KEY PAINT FINISH KEY LAKEWOOD, COLORADO 80226 I COMMERCE CITY, CO 80022 (303) 534 -1930 FAX (303) 534 -1931 1 C ELEC./ MECH./ PLUMB. ENG CATOR, RUMA AND ASSOCIATES - 1550 DOVER STREET, SUITE 2 LAKEWOOD, COLORADO 80215 (303) 232 -6200 - FAX (303) 233 -3701 M101 ELECTRICAL E 1.0 E2.1 FIRE ALARM FA1.1 FPl .1 FIRST FLOOR MECHANICAL PLAN 1/4" = l' -0" ELECTRICAL LEGENDS AND SCHEDULES NO SCALE FIRST FLOOR LIGHTING AND POWER PLAN 1/16" = 1 i " TENANT FIRE ALARM 1/4 — 1 -0 FIRE PROTECTION 1/4 = 1' -0" ~ )"� "'Cl � 4 C) W }� J� � Q P4 Fri .t WALL HEIGHT TO UNDERSIDE OF STRUCTURE .2 WALL HEIGHT TO 4" ABOVE CEILING CEILING TYPES TYPE DESCRIPTION DIAGRAM cJ 2'x2' ARMSTRONG ULTIMA CEILING PANELS W/ 9/16 BEVELED TEGULAR GRID N FROM EXISTING ROS STRU ABOVE. CODE REVIEW LOCATION: ARRABELLE AT VAIL SQUARE 450 EAST LIONSHEAD CIRCLE VAIL, COLORADO 81657 �� (1) LAYER 5 /$" GYPSUM BOARD ON $' HAT CHANNELS ON 1 2 BLACK IRON SUSPENDED FROM EXISTING STRUCTURE ABOVE. _ "� - _ � - '��'��� '� ���� � ' � NOTE: PER IMC 602.2.1 ANY EXPOSED MATERIAL IN THE PLENUM SPACE SHALL AVE A FLAME SPREAD INDEX OF NOT MORE THAN 25, AND A SMOKE - DEVELOPED INDEX PLYWOOD NORTH ARROW PLI CABLE CODES: GLASS LARGE SCALE GLASS SMALL SCALE BATT INSULATION RIGID INSULATION ROOM NAME a0t ® F ROOM NAME / NUMBER KEY ALIGN FACE OF FINISH CENTER LINE OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. t 2003 INTERNATIONAL BUILDING CODE TOWN OF VAIL AMENDMENTS TO THE 2003 IBC 1 2003 fNTERNATIONAL PLUMBING CODE/ T.Q.V. AMENDMENTS 2003 INTERNATIONAL MECHANICAL CODE/ T.O.V. AMENDMENTS 2005 NATIONAL ELECTRICAL CODE/ T.O.V. AMENDMENTS 2003 INTERNATIONAL FIRE CODE/ T.O.V. AMENDMENTS M z a p M w U N z V ° ° - _ x U a ° _° Q � V � Z •n y w z a PROPOSED: SPRAY ON FIREPROOFING VI CINITY MAP: CONSTRUCTION TYPE: 1 B - FULLY SPRINKLERED OCCUPANCY TYPE: M - WITHIN A NON - SEPARATED MIXED USE - S -1 MOST STRICT WITHIN BUILDING ACOUSTICAL CEILING TILE CARPET *. «. LOCATION OF (N) LANDMARK ACTIVITIES DESK - RETAIL LIFT HOUSE 0 ✓r�l! « • * '� . •+•Z '� LODGE � FIRE SEPARATIONS: FIRE SEPARATIONS ARE NOT REQUIRED BETWEEN USES PER IBC 302.3.1 -- -- F 7 • `• �'` EXTERIOR GYPSUM SHEATHING GYPSUM BOARD METAL LATH AND PLASTER EXTERIOR INSULATED FINISH SYSTEM (EIFS) �� MEDIUM DENSITY FIBERBOARD SAND, GROUT SHEET METAL, STEEL ANGLES, ETC. STONE RUBBER / FLEXIBLE MATERIAL ARRABELLE @ VAIL SQUAR CONCERT ' ` ?� ' MONTANEROS � o *•' "' �-*-� � ._ .. � • .__... -_ � s • NSOUAR n NORT • ; �i vAR . "� I • ', .. ,� U � A H R EAD ° ° +� a 1 . - LIONSHEAD CENTRE - ► ,��,.._..,.- � _ , k - ` . ._ ._.........,._.....,..... -.__ -; 110.414..111.. / --- �ra'ee*boe R I R F"T / BARN #8"` OD ONDOLA UMME _ -• _ �-'' `. WI TER z � � "'— s ^� " "' °-- •..,�. ^ f OCCUPANCY LOAD: AREA: 739 S.F. LOAD FACTOR: 30 OCCUPANT LOAD: 25 PLAN REVIEW RESPONSE $ - 30 - 07 HEIGHTS: ALLOWABLE: FOR MOST RESTRICTIVE USE ( S -1 ) 1 1 STORIES + 1 48,000 S.F. AREA - PER IBC TABLE 503 ACTUAL: 1ST STORY OF 7 STORIES 15,850 S.F. ENTIRE BUILDING FOOTPRINT PERMIT 7 -1 3 -07 IS sUED FOR: PLUMBING FIXTURES: RESTROOMS M OCCUPANCY: WATER CLOSETS - 739 / 500 = 2, 1 MALE, 1 FEMALE; LAVATORIES 739 / 750 = 1 EXISTING PUBLIC RESTROOMS LOCATED ON LEVEL ONE = FEMALE - 3 W.C. 2 LAV.; MALE = 1 W.C., 2 URINALS, 2 LAV. ,�,,� 4� '' ° ° " �� - • �� '�"„ ', e? 11 - Llixf 1 R. +'`•- � `' ° °`,` EXITS: MAXIMUM OCCUPANCY FOR SPACES WITH ONE MEANS OF EGRESS PER IBC TABLE 1014.1: FOR M OCCUPANCY = OCCUPANT LOAD OF 50. ACTUAL OCCUPANT LOAD = 25 THESE DRAWINGS AND SPECIFICATIONS AND THE DE REPRESENTED HEREBY ARE SWINGE AND REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO ABBREVIATIONS OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS, WRITTEN ABV ABOVE CIR AFF ABOVE FINISHED FLOOR CLR CIRCLE EXIST, (E) CLEARANCE) EXT EXISTING EXTERIOR FUR FURRED(ING) GA GAGE, GAUGE INS, INSUL INSULATE(D)(ING) INT INTERIOR MAX MAXIMUM PVC POLYVINYL CHLORIDE RO MECH MECHANIC(AL) PTC POST - TENSIONED CONCRETE RB ROUGH OPENING TOS RUBBER BASE TOW TOP OF STEEL TOP OF WALL DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND HIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS M CONDITIONS F SOOWN " BY D THESE S DR N AWINGS.. ACT ACOUSTICAL CEILING TILE COL COLUMN FB FACE BRICK GALV GALVANIZED JAN JANITOR MDF MEDIUM DENSITY FIBERBOARD PSF POUNDS PER SQUARE FEET SCHED SCHEDULE TEX TEXTURE ALT ALTERNATE COMB COMBUSTIBLE FOC FACE OF CONCRETE /CURB GC GENERAL CONTRACT(OR) JC JANITOR CLOSET MTL METAL PSI POUNDS PER SQUARE INCH SHT SHEET T TREAD ARCH ARCHITECTURAL) CONC CONCRETE FOF FACE OF FINISH GL GLASS, GLAZING JT JOINT MIN MINIMUM PC PRECAST CONCRETE SV SHEET VINYL TYP TYPICAL AD AREA DRAIN CMU @ AT CJ CONCRETE MASONRY UNIT FOM CONTROL JOINT FOS FACE OF MASONRY FACE OF STUD GT GROUT GYP BD GYPSUM BOARD KPL KICKPLATE KIT KITCHEN MISC MISCELLANEOUS PFN PREFINISHED SIM MLD MOLDING, MOULDING PL PROPERTY LINE SC SIMILAR UNO SOLID CORE VIF UNLESS NOTED OTHERWISE VERIFY IN FIELD PROJECT INFORMATION AUTO AUTOMATIC DEMO DEMOLISH, DEMOLITION FIN FINISH(ED) GWB GYPSUM WALL BOARD KO KNOCKOUT (N) NEW QT QUARRY TILE S SOUTH VERT VERTICAL AVG AVERAGE DIM DIMENSION FFE FINISHED FLOOR ELEVATION HDW HARDWARE LAM LAMINATE(D) N NORTH RAD RADIUS SPKR SPEAKER VB VINYL BASE BD BOARD DW DISHWASHER FFL FINISHED FLOOR LINE HDR HEADER LAV LAVATORY NIC NOT IN CONTRACT RE: REFER TO, REFERENCE SF SQUARE FOOT VCT VINYL COMPOSITION TILE BSMT BASEMENT DR DOOR FE FIRE EXTINGUISHER HTG HEATING LH LEFT HAND NTS NOT TO SCALE RCP REFLECTED CEILING PLAN STD STANDARD VF VINYL FABRIC BM BENCHMARK DN DOWN FEC FIRE EXTINGUISHER CABINET HVAC HEATING, VENTILATION, AIR CONDITIONING L LENGTH OC ON CENTER(S) REF REFRIGERATOR STL STEEL VWC VINYL WALL COVERING B.O. BY OWNER DWG DRAWING FPL FIREPLACE HT HEIGHT LT LIGHT OPG OPENING REQ'D REQUIRED STOR STORAGE WC WATER CLOSET BLDG BUILDING DF DRINKING FOUNTAIN FP FIREPROOF HDF HIGH DENSITY FIBERBOARD LTG LIGHTING OPP OPPOSITE RA RETURN AIR STRUC STRUCTURAL WP WATERPROOFING) CPT CARPET(ED) EA EACH FLR FLOOR HC HOLLOW CORE LTL LINTEL OD OUTSIDE DIAMETER RAG RETURN AIR GRILL SYS SYSTEM W WEST AO. 1 CIP CAST -IN -PLACE E EAST FD FLOOR DRAIN HM HOLLOW METAL LVR LOUVER PT PAINT REV REVISION(S), REVISED TEL TELEPHONE WIN WINDOW CK CAULK(ING) ELEC ELECTRIC(AL) FLUOR FLUORESCENT HORIZ HORIZONTAL MFR MANUFACTURE(D) PTD PAINT(ED) RH RIGHT HAND TV TELEVISION W/ WITH VERIFY FIRESTOPS AT FLOOR AT MECH. PIPES MICRO SKI RACKS A8.1 UC REF. r I N ALL I >: 0 ALL L-L J SAFE 4'-0% V.I.F. A L BELOW L -- - - - - - Fl OFFICE 0 1 1 0 A j 2 B A8.1 11 _1� 8'-0 5/8" 0 3 A8.1 A 00 I- Lo 1 Fl r A7.1 OE CASH COUNT COAT HOOKS E__ --------------- J BOX + 12" 1 J BOX + 11 2" TV 4 CLEAR 4 F 1 A8.1 A8.1 3'-1 1/2" it1111 15-1 1/2• A ----------- 4 A71 B El I +34 0 0 t34 01 T LD48 FLOOR 1 +42 1 ADA COUNTER — — — — — — — — 5 A8.1 A — — - 3 A7.1 B C F2 F2 W SALES CUE _j ACTIVITIES MECCO SHADES @ F)I:Qv EAST WINDOWS 4", CLEAR BROCHURE RACK BENCH WATER 5 A10.1 FLOOR PLAN. SCALE: 1/2" = 1'-0" SUMMER WINTER REFLECTED CEILING PLAN SCALE: 1/2" = I'*' SYSTEM NOTES WALLS Vyl 3 5/8" MTL. STUDS @ 16 " O.C. WITH ONE LAYER 5/8" G.W.B. EACH SIDE W/ 3-1/2" ACOUSTICAL INSULATION BETWEEN STUDS <s (E) DEMISING WALL - REQUIRED 2 HOUR SEPARATION - V.I.F., SEE > SHEET A0.1 ,0 - RE: DETAIL FOR HEIGHT .I - TO UNDERSIDE OF DECK .2 - TO CEILING .3 - TO 4" ABOVE CEILING .4 - INFILL CEILINGS/FLOORS PAINTED 5/8" G.W.B. ON MTL. STUD FRAMING < 8 C2 - (N) ACOUSTICAL CEILING TILE CEILING 1 �> Ft -3" GYPCRETE TOPPING OVER EXIST. STRUCTURE TO F.F LEVEL 8132'. - CPT 102 INSTALLED ON FIN. FLOOR < s813 2'. -31 GYPCRETE TOPPING OVER EXIST. STRUCTURE TO F.F LEVEL > , ACCENT CPT INSTALLED PER INTERIOR DESIGNER, NERAL OTE : 1. UNLESS OTHERWISE NOTED OR DETAILED, ALL INTERIOR WALLS AND PARTITIONS SHALL BE CONSTRUCTED FULL HEIGHT TO THE UNDERSIDE OF STRUCTURAL DECK ABOVE. 2. VERIFY LOCATIONS OF EXIST COLUMNS INSIDE GYP BID. WRAP, NOTIFY ARCHITECT OF ANY DISCREPANTCY. 3. GYP. BD, INSTALLED IN "WET" LOCATIONS SHALL BE MOISTURE-RESISTANT. 4. DIMENSIONS ARE TO FACE OF STUD AT NEW WALLS, AND TO FACE OF EXIST. WALLS. UNLESS OTHERWISE NOTED. 5. DIMENSIONS TO DOWNLIGHTS & PENDANTS ARE TO qOF FIXTURE, TYPICAL U.O.N. 6. VERIFY ALL EXISTING. CONDITIONS. NOTIFY ARCHITECT OF ANY DISCRPANTCIES. 1:1 - 2x2, 2x4 FLUORESCENT TROFFER 0 0 III I Q RECESSED WALL WASHER + PENDANT FIXTURE f�71 Al RETURN AIR GRILLE EXHAUST LINEAR SLOT DIFFUSERS SUSPENDED GYPSUM BOARD (PAINTED U.O.N.) ------ FLUORESCENT STRIP FIXTURE nc - SECURITY CAMERA v SUMMER WINTER REFLECTED CEILING PLAN SCALE: 1/2" = I'*' SYSTEM NOTES WALLS Vyl 3 5/8" MTL. STUDS @ 16 " O.C. WITH ONE LAYER 5/8" G.W.B. EACH SIDE W/ 3-1/2" ACOUSTICAL INSULATION BETWEEN STUDS <s (E) DEMISING WALL - REQUIRED 2 HOUR SEPARATION - V.I.F., SEE > SHEET A0.1 ,0 - RE: DETAIL FOR HEIGHT .I - TO UNDERSIDE OF DECK .2 - TO CEILING .3 - TO 4" ABOVE CEILING .4 - INFILL CEILINGS/FLOORS PAINTED 5/8" G.W.B. ON MTL. STUD FRAMING < 8 C2 - (N) ACOUSTICAL CEILING TILE CEILING 1 �> Ft -3" GYPCRETE TOPPING OVER EXIST. STRUCTURE TO F.F LEVEL 8132'. - CPT 102 INSTALLED ON FIN. FLOOR < s813 2'. -31 GYPCRETE TOPPING OVER EXIST. STRUCTURE TO F.F LEVEL > , ACCENT CPT INSTALLED PER INTERIOR DESIGNER, NERAL OTE : 1. UNLESS OTHERWISE NOTED OR DETAILED, ALL INTERIOR WALLS AND PARTITIONS SHALL BE CONSTRUCTED FULL HEIGHT TO THE UNDERSIDE OF STRUCTURAL DECK ABOVE. 2. VERIFY LOCATIONS OF EXIST COLUMNS INSIDE GYP BID. WRAP, NOTIFY ARCHITECT OF ANY DISCREPANTCY. 3. GYP. BD, INSTALLED IN "WET" LOCATIONS SHALL BE MOISTURE-RESISTANT. 4. DIMENSIONS ARE TO FACE OF STUD AT NEW WALLS, AND TO FACE OF EXIST. WALLS. UNLESS OTHERWISE NOTED. 5. DIMENSIONS TO DOWNLIGHTS & PENDANTS ARE TO qOF FIXTURE, TYPICAL U.O.N. 6. VERIFY ALL EXISTING. CONDITIONS. NOTIFY ARCHITECT OF ANY DISCRPANTCIES. 1:1 - 2x2, 2x4 FLUORESCENT TROFFER 0 0 RECESSED DOWN LIGHT; GYP. BD. , ACT Q RECESSED WALL WASHER + PENDANT FIXTURE f�71 SUPPLY AIR DIFFUSER/GRILLE RETURN AIR GRILLE EXHAUST LINEAR SLOT DIFFUSERS SUSPENDED GYPSUM BOARD (PAINTED U.O.N.) ------ FLUORESCENT STRIP FIXTURE nc - SECURITY CAMERA CORBEL, SEE ELEVATIONS AND 3/A10.1 r-'l �14 � o c C) U z Z 0 o u 0 Z2 O Z - < z < ADDENDUM #1 8-30-07 - PLAN REVIEW 8-30-07 PERMIT 7-13-07 ISSUED FOR: DM" ' ( ......... AZ MEL, JR. THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. FLOOR PLAN I kEFLECTED CEILING PLAN M % I AKI M 1= Ll- ELEVATION KEY NOTES: O P,LAM COUNTERTOP 11 REFRIGERATOR - PROVIDED BY lb �'_ �v_� == ��,�'� - -�. -�_ _ _,�__� ��� -_; -�.�- OWNER, VERIFY SIZE. CD GRANITE COUNTERTOP MICROWAVE - PROVIDED BY 7 SKI RACKS OWNER, VERIFY SIZE. CD PAINTED METAL COPY MACHINE, BY OWNER, DOOR/WINDOW FRAME -------- VERIFY SIZE C? (D PAINT WD PANELED HALF HEIGHT 0 60 ao CD 1 80 DOOR, RE: DOOR SCHEDULE Eo 19 (D GYP BD. SOFFIT, PAINT CID — r 4 CD WOOD PANELED MILLWORK (]DWD CORBEL C? (D P.LAM CABINETS 6" WOOD BASE, STAINED z) 17 VINYL WALL COVERING ( D STAINED WOOD CROWN MOULDING C 10 C? 0 RUBBER BASE SEE SHEET Al 0. 1 FOR FINISH SPECIFICATIONS P-LAM COUNTERTOPS, SEE SHEET L A8,1 A B � � CASH COUNT OFFICE u SCALE: 1/2" 1' - O" SCALE: 1/2" l'-O" > (:D� 0 CD] i ► c) f I k \- ----' '� 15 2 2 C:D > CD zo c� z 6 0 CD 7 0 cl 4 ACTIVITIES DESK SCALE: 1/2" = P-0" 31-10" CD j�i r ---------- - - - - - PLAN REVIEW 8-30-07 PERMIT 7-13-07 BROCHURE" C? ISSUED FOR: DATE, 19 011 60 RACKS L ---------------- j - 0 olp 0 C= THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO 1$ OTHERS OR USED IN CONNECTION WITH ANY . . . . . . . . . . . . 3 (E) '-6 3/8" , l'-6 3/8" L L -J L - - J L J L - - --- - -i L 0 0 7 F L CN L J L - - - - - - - L TV 131-911 1 1 z ---------- --------------- ���;; T -- --IT CD F F ------------- --------------- ------ 0, ............ ------ ---- -------------- - --- -------- --------------- - ------------ 1 1 1 t I I 1 ---- Ll ' 3/8" 1'-6 3/8 1'-6 3/8fl V-6 3/8' l'-6 3/8 (E) '-6 3/8" , l'-6 3/8" L L -J L - - J L J L - - --- - -i L 0 0 7 F L CN L J L - - - - - - - L WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 60 INTERIOR ELEVATIONS r `0 ;o co A7.1 0 z ---------- --------------- ���;; T -- --IT CD F F ------------- --------------- ------ 0, ............ ------ ---- -------------- - --- -------- --------------- - ------------ 1 1 1 t I I 1 ---- Ll WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. 60 INTERIOR ELEVATIONS r `0 ;o co A7.1 0 SEALANT, TYP. BLOCK A3K8QQ _— P-LAM WRAP ALL EXPOSED SURFACES, VERIFY SELECTION WY OWNER/INTERIOR DESIGNER. \/2" PLYWOOD SUPPORT FIN ZCONTINUOUS WD COUNTER SUPPORT AS cy) 1 9 GRAN &BACKSPbASH, STAINED WOOD FLUSH RN DRAWERS AND D' 3/4"AD]USTAE kXEU MELAMINE INTERIOR SURFACES ( AND SHELVE ��/�T|��k] � SECTION |\_�|� \��� BUILT DESKS SCALE ] 1/2 ,= ]L0 DOK DECORATIVE PANELS: �DDDY k»DF FENEERON k»DF 0[T|ONF|T �J SNEDWD 8LUETO PERELEVAT(] PARTITION WALL & STA HARDWOOD ANGLE. 2x4 WD DIEY P|ANDH|NGE,TYP. VENEER PLYWOOD (}R COUNTER PER WOOD VENEER DNMDF. 3/4 SIDE FRICTION FIT & GLUE TD PARTITION WALL. MITER @ CLEAR FOR CASH DRAWER ABA � mUv^r i 4;-9 -----' STUD WALL: STA 3/4 VENEER PLYWOOD DN2x4 STUDS TURNED SIDEWAYS. OPT: WOOD VENEER MDF TRANSACTION COUNTER TYP. TICKETING DESK PROVIDE GROMET AS REQD. = rr .~ _ TYPICAL INDOOR TICKETING PLAN A& 1 PARTIT WALL BEYOND, RE: 8/A8.1 FOR CNTR DETAILS, COUNTER SECTION SC/\[E: ]n == lL0 STA WOOD CAP l/ BLACK REVEAL, TYP ` STAINED HARDWOOD VENEER 3/4"PLYWOOD ------ ON2x4STUDS TURNED FLAT. GRANITE COUNTER PER SPECS DRAWER MVPULL HARDWARE PER SPECS 3/4" ADJUSTABLE SHELF Wy MELAMINE FINISH PER SPECS FLUSH WOOD FRAME, DOORS AND DRAWER FRONTPERSPECS ---�-- �| ^ PARTITION WALL: 3/4" PLYWOOD ON2x4STUDS TURNED SIDEWAYS. STAIN. 2U GA. ANGLE. MITER ATPANEL CORNERS. ATTACH TD PARTITION WALL. Lu � _> ce P.LAMATNlEXPOSEDFACBOF[A0|NB DRAWERS AND DOORS AS INDICATED 3/4" ADJUSTABLE SHELF WyMELAMINE FINISH METAL PULL P.LAW WRAPPED 8A[KSPLASHAND COUNTERTOP � CD���^ p[�OOD � )& LYW STAINED H�D� P OO �DDD' � o 10 10 P.LAWATAL EXP{}SEDFACESOFCAB|NET DK4WERSANDDDDRS4S|ND�/TED 3/4"ADJUSTABLESHELFWyy�ELAM|NE--_� F|N|SH MELAMINE �|NE F|N|SH ATALL |NTER|OR SUKFACESOFDR/ANERSANDSHELYES 3 � �~rt��||�x_ | /��D|k]�T ���—T|��kJ ^J�_�~ | |\_/| SCALE: P P-101" H�RDYY OOD3/4 GRANRE[O� DOK CLOSED POSITION �DDDY k»DF FENEERON k»DF 0[T|ONF|T �J SNEDWD 8LUETO PERELEVAT(] PARTITION WALL & GRANITE ANGLE. 2x4 WD DIEY P|ANDH|NGE,TYP. � _ � � ^ ` — _T � � � _ SC/\[E: ]o == ]-O FINGER SLOTS _ /t — SERVICE COUNTER SECTION BLOCKING AS REQD. FOR BROCHURE RACK AU y L BLOCKING AS REQD. cp ER ` C? BROCHURE RACK FRONT ELEVATION \ SIDE 8EY(]ND ~ \ _ � � GRANO &BA[KSPbA3H, STAINED WOOD FLUSH PA| ORAWERS, Oat MELAMINE INTERIOR SURFACES < AND SHELVE � Lu ui � 2z COUNTER SECTION A LOST D FOUND DRAWERS SC/\[E: 3" = l GRANITE COUNTER N0BLKGASREQU|RI 2x4 WD DIE WALL— Lu STAINED HARDWOOD PLYWOOD OR WOOD Lu ce YENEERMDF 10 _ — CLOSED POSITION OPEN POSITION GRANITE STORAGE SHELF, TYP. P|ANDH|NGE,TYP. COUNTER PER 3/4 SIDE CLEAR FOR CASH DRAWER SPECS CASH DRAWER Lu TVYOFOiD'DOYVN [OPEN SUPPORT AS REQD. ROW DOORS PER ROW HARDWARE PER SPECS — 3/4" ADJUSTABLE SHELF W/ z' BOCA CPU MELAMINE FINISH PRINTER PER SPECS LAMINATE FRAME, Zu ' r DOORS AND m EPSON DRAWER FRONT PRINTER PER SPECS -~^ ER ` C? BROCHURE RACK FRONT ELEVATION \ SIDE 8EY(]ND ~ \ _ � � GRANO &BA[KSPbA3H, STAINED WOOD FLUSH PA| ORAWERS, Oat MELAMINE INTERIOR SURFACES < AND SHELVE � Lu ui � 2z COUNTER SECTION A LOST D FOUND DRAWERS SC/\[E: 3" = l GRANITE COUNTER N0BLKGASREQU|RI 2x4 WD DIE WALL— Lu STAINED HARDWOOD PLYWOOD OR WOOD Lu ce YENEERMDF 10 _ — ADATRANSACTION COUNTER SECTION SC/\[E: ] 1/2 == ]L0 _-_-----BUMPER CLOSED POSITION OPEN POSITION STORAGE SHELF, TYP. P|ANDH|NGE,TYP. SUPPORT AS REQD. ADATRANSACTION COUNTER SECTION SC/\[E: ] 1/2 == ]L0 _-_-----BUMPER CLOSED POSITION OPEN POSITION STORAGE SHELF, TYP. P|ANDH|NGE,TYP. STAINED WOOD 00 � w _ _ _ -. _ u z 5 �� "� ~ � 0 0 � a� � o ��< < o ~ � ^ o=� v - - -~` � �-^� U ~ ~`-~ U PLAN REVIEW 8-30-07 PERMIT 7-13-07 ISSUED FOR: ELI �--. "3V'23 THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAJN PROPERTY Of THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITHANY WORKORPROJECT FOR WHICH THEY HAVE BEEN PREPAREDWITHOUT THE WRITTEN CONSENTOF THEARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY ACCEPTANCE OF THESE RESTRICTIONS, WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. MILLWORK DETAILS DOOR SCHEDULE: R OOM FINISH SCHEDULE. REMARKS RM NO. • ROOM NAME DOOR FRAME FIRE HDW FLOOR N. WALL E. WALL S. WALL W. WALL CEILING W HT T TYPE MAT FIN HEAD JAMB THRESH. TYPE MAT FIN RATE NO. NO. MAT. FIN. BASE MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. MAT. FIN. D 100E (E) (E) - (E) - - - (E) 1 /Al 0.1 (E) - - 4 - 100 ACTIVITIES DESK (E) CONC. CPT 6" WD VWC GYP. PT GYP. PT GYP. PT GYP PT D100 31 -0" 3-0" 1 5/8" D2 WD STAIN - - /A8.1 - 1 - 101 CASH COUNT (E) CONC. CPT 6" RB GYP, PT GYP. PT GYP. PT GYP. PT ACT D101 3' - 7' - 0 " 1 3/4" Dl WD STAIN 2/A10.1 - F1 MET I PAINT 2 102 OFFICE (E) CONC. CPT 6 "RB GYP. PT GYP. PT GYP. PT GYP. PT ACT D102 3' - 0 " 7' - 0 " 1 3/4" D l WD STAIN 2/A10.1 - F 1 MET PAI NT 3 DOORS: F H ACOUSTICAL CEILING TILE: Cabinet Hardware Pendant Lights 9 Manufacturer: Baldwin Manufacturer: Tech Lighting ACT: (N) ARMSTRONG ULTIMA 2 X 2 ACOUSTIC CEILING TILE IN (N) T9-6` Item: Cabinet Knob Model: Echo SUPRAFINE GRID; REFER TO CEILING PLAN FOR ACTUAL LOCATIONS. Style: .625 Diameter Classic Knob Finish: Antique Bronze SKU: 4700 Shade: Amber 2" 2" Carpet - CPT 102 Finish: Oil Rubbed Bronze Size: 11.4" Height x 8.9" Diameter HARDWARE TYPE 1: Manufacturer: Interface Location: All cabinet doors /drawers 1 PAIR DOUBLE ACTING PIVOT HINGES Source: Spaces Lamp: T4 with El I minicandelabra base, MAGNETIC CATCH LATCH Contact: Cody 303 - 471 -4334 Pyrex glass shade. Max 60 watt, Carpet Tile 120 volt. � 2 WAIL STOPS Product: Coat Hooks Material: Nylon Manufacturer: Baldwin Y Location: Room 100 HARDWARE TYPE 2: Pattern: 124I6 Item: Coat Hook Quantity: 3 over activities desk 1 1/2 PAIR BUTT HINGES Color: 6834 Watson Collection: Cecina Contemporary 3 ` d` 1 LEVER - CLASSROOM FUNCTION Size: 19.69" x 19.69" Finish: Oil Rubbed Bronze Note: Room 101 and 102 to have ceiling tile with fluorescent fixture. 1 CLOSER W/ OVERHEAD STOP Construction: Tufted Texture Loop Location: Side wall Room 101 Tile and fixture size 2'x 2'. Selection of fixture by electrical contractor. HOLD OPEN Stitches per inch: 9/ inch as shown on floorplan SILENCERS Finished Pile Thickness: .149 Door Stops Gauge: 5/32 inch Manufacturer: Baldwin HARDWARE TYPE 3: Style: o Total Weight: 24 oz. per sq. yd. tY Wall Flush Bummper 4015 or 1 1/2 PAIR BUTT HINGES Primary Backing: alf Dome Bumper 4000 CN 1 LEVER - CLASSROOM FUNCTION Bonding Agent: Per manufacturer Finish: Oil Rubbed Bronze 102 WALL STOP Installation: Set tiles square Rubber Base Interior Door Hardware Testing Information: ASTM E -64$, ASTM Inter Manufacturer: Roppe D -662 Note: Match interior door hardware in adjacent spaces if possible. Style: No Toe Base D t D2 HARDWARE TYPE 4: AATCCI6 -E, AATCC -134 Alternate Selection (if needed): Size: 4" height Note: Only one pattern used due to small size of space. Use in all rooms Manufacturer: Baldwin Color: 110 Brown FLUSH WOOD DOOR 3 F1 (E) HARDWARE TO REMAIN FLUSH WOOD DOOR - 2 LAYERS 4 INSTALLATION OF N FLOORING Contemporary Location: Room 101, 102 '° 100, 101, 102 Series: PLYWOOD APPLIED WOOD PANELS, PAINTED METAL FRAME VERIFY (E) THRESHOLD IS ORI N COMPLIANT FOR Style Number: 5137 STAINED () ORIG Countertop - ST 100 Finish: Oil Rubbed Bronze Plastic Laminate Countertops - PLAM Source: Capco Note: Door locking systems are to be reviewed and specified by the Project Manufacturer: Wilsonart Contact: Pat Gooch 979 -513 -7901 Manager per operational needs. Pattern: Hunter Nebula Material: Slab Granite Color: 4627 -60 Color: Pine Green Doors and Half Hcight Swinging Door Edge Detail: Square cut laminate Size: 3 cm Stain Grade Door and 4" Casing - Specification by Architect Backsplash: 4" height square Edge Detail: Eased edge top and bottom Finish: WD 100 Location: Room 101 Location: Activities Desk Counter top Hinges: Oil Rubbed Bronze Desk Surface for Room 102 (work surface & customer if built in. surface - both heights) Paint - PT 107 Note: Color to be confirmed. Manufacturer: Benjamin Moore Note: Color to be confirmed. Color Number: 1045 Color Name: Lady Finger Cabinets Wood /Stahl - WD 100 Finish: Eggshell Source: Home Depot or Other Manufacturer: N/A Application: 2 coats rolled over prime coat Manufacturer: Contractor to select Description: Millwork Location: Room 100, 101, 102 Door Style: Flat Panel/Contemporary Species: White Oak Note: Wall paint ceiling inside of coffers., full height walls Rooms 100, 101 and Wood: White Oak Cut: Clear grain, no knots 102. Back wall (behind transaction counter of Room 100 to have accent Finish: Stain to match Wood 101 Color /Stain: N/A wallcovering)• Location: Room 101 Size: Refer to architectural Note: Order standard cabinets unfinished in White Oak is possible, stain to Elevations and details Paint - PT 108 match Finish: Match wood finish at Manufacturer: Sherwin Williams WD -101 Arabelle Mountain Ops. Color Number: 6126 Project Manager to obtain Color Name: Navajo White Microwave stained sample from job site to Finish: Eggshell Source: Home Depot match. Application: 2 coats rolled over prime coat. Manufacturer: General Electric Sheen: 40% Location: Drywall ceilings. Model Number: Profile JES2251SJ Location: Custom millwork Room 100 Wall Covering - WC 101 Style: Cabinet Inset wood panels on front Manufacturer: Luxe Surfaces Finish: Stainless Steel of transaction counter. Pattern: Findley Size: Width 24 ", Height 13.78" Collection: Opus Depth: 19.41" Wood/Stain- WD 101 Color: LXO- OPS -07 Manufacturer: N/A Type: Type lI Undercounter Refrigerator Description: Millwork Width: 52 "/54" Source: Home Depot Species: White Oak Location: Wall covering back wall Room 100 Manufacturer: General Electric Cut: Clear grin, no knots (behind activities desk counter) Model Number: GMR04HASCS Color /Stain: N/A Style: Cabinet Size: Refer to architectural Ceiling Lights Finish: Stainless Steel /Clean Finish Elevations and details Manufacturer: CP Lighting Size: Width 20.50" Height 32.75" Finish: Match wood finish at Contact: Christopher Poehlmann Depth 21" Arabelle Mountain Ops. 866 -597 -4800 Project Manager to obtain Model: Custom Pendant Light fixture stained sample from job site to with match. Acrylic drum and diffusers Sheen: 40% Finish: Bronze Location: Custom millwork Room 100 Shade Color: Neutral Tan or Taupe Base and (Crown, base, chair rail, Burnt Umber Edges corbels, window casing, Size: 20" diameter, 10" height Front of transaction counter. Lamp: (3) PLT- 26W /SPX27 /4P /ALTO Door stain/casing to match) lamps Location: Over activities counter Quantity: 4 (E) STOREFRONT SYSTEM BEYOND INTERIOR (N) ALUMINUM DOOR TO MATCH I 4 1 (E) (N) THRESHOLD; I I MATCH WIDTH OF CARPET (E) STOREFRONT SYSTEM; SET s THRESHOLD IN (E) CONCRETE SEALANT BED FLOOR € 3 (E) EXTERIOR WALK ! , L SCALE: 3" = P -0" a 2 X BLOCKING 3 -PIECE PAINTED METAL FRAME SCHEDULED DOOR SEALANT, TYP. BOTH SIDES TYPICAL INTERIOR JAMB DETAIL SCALE: 3" = P -0" 3 CORBEL PLAN 4 A10.1 SCALE: 1 1/2" = 1' - 0 " A10.1 CV 10 IVA i ! X01 a — 111110111 SCALE: 1 1/2" = P -0" $" GYP. BD ' WATER LINE, RE: MECH. 1 5/8" MTL STUD, HOLD FROM WALL AS REQD FOR WATER LINE ACCESS CONTINUOUS ELASTIC SEALANT, TYP. EXIST. EXTERIOR WALL • ° s s .. 11 NJ a FA K SCALE: 3 " = P -0" ii i • • 1 i a • r/ Z � Q 0 M O O O � w V O M H � « P a o z V _ z W V THESE DRAWINGS AND SPECIFICATIONS AND THE IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN PROPERTY OF THE ARCHITECT, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT FOR WHICH THEY HAVE BEEN PREPARED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS, WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB, AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SCHEDULES