Loading...
HomeMy WebLinkAboutB07-0260 E07-0224: Entries for Item:190 - ELEC-Final 12:09 07/02/2013 Action Comments By Date Unique_ Ke CR ABOVE COUNTER KITCHEN RECEPT TO SHAHN 12/17I2007 4880109 BE GFI. RELOCATE SOUTH EXIT TO BE VISIBLE. REPLACE DEFECTIVE EXIT IN KITCHEN. AP shahn 12/1812007 A000109 566 Total Rows:2 Page 1 . i P07-0169: Entries for Item:290 - PLMB-Final 12:10 07/02/2013 Action Comments By Date Unique_ Ke PA CAULK ALL FIXTURES IN KITCHEN GCD 12/17/2007 4900109 AP GCD 12/20/2007 A000109 995 Total Rows: 2 Page 1 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT COMM BUILD PERMT Permit # B07-0260 Project# PRJ07-0365 Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.......: ARRABELLE HOTEL Applied .. . : 08/07/2007 Parcel No....: 210106325001 Issued . . . : 09/07/2007 Expires.....: 03/OS/2008 OWNER ARRABELLE AT VAIL SQUARE LLC08/07/2007 �J�_` �^C� �V UL{ -�3C�J PO BOX 7 --� 1 VAIL CO 81658 APPLICANT TCD, INC. OS/07/2007 Phone: (970) 453-3959 PO BOX 4564 BRECKENRIDGE �� �J 3 COLORADO 80424 S--c( License: 353-A �``� 4 CONTR.ACTOR TCD, INC. 08/07/2007 Phone: (970) 453-3959 ` M��`� PO BOX 4564 �� ` BRECKENRIDGE COLORADO 80424 License: 353-A ! v� �c�d��--� Desciption: TENANT FINISH WORK FOR THE BLUE MOOSE AT ARRABELLE Occupancy: A-2 Type Construction: I-B Valuation: $491,510.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 ******�*****:r***x*r*►*****+*►�*t**r**r******sr*****r*****s�s**r*�*�* FEE SUMMARY *****r*r***************r*a**�*�****��**+**�***t**tt**��****+ Building------> $3,18B.95 Restuarant Plan Review--> $�5.oo Total Calculated Fees--> $5,339.77 Plan Check---> $2,o�2.8 z Recreation Fee--------------> $o.o o Additional Fees----------> $o.o 0 Investigation-> $o.o o T07'AL FEES-------------> $5,3 3 9.�7 Total Permit Fee---------> $5,3 3 9.�� Will CaII-----> $3.0 0 Payments-------------------> $5,3 3 9.7 7 BALANCE DUE---------> $o.o 0 ***�*�►*a+**stsx***r*e****t�tt**:+t*****�r*�***s*�***�:+s**«ts«��**�****a►+►r****r***r�**�*******�*�**►�*****�sss**�:vsx*r**+****t***►*r**�*►**�*�* Approvals: Item: 05100 BUILDING DEPARTMENT 08/30/2007 cgunion Action: CR plan review comments sent F: \cdev\CHRIS\PERMIT.COMMENTS\B07-0260\B07-026U .DOC 09/05/2007 cgunion Action: AP approved resubmitted plans addressing code comments. Item: 05400 PLANNING DEPARTMENT 09/06/2007 George Action: AP Item: 05600 FIRE DEPARTMENT 08/17/2007 JJR Action: AP Approved as noted: Exititng plan conflicts with E300. Furniture is shown blocking claimed exit doors . Provide adequate exit signage. Item: 05500 PUBLIC WORKS 09/05/2007 tk Action: NA � *:*****,��,......::.:*******.*.«*►.*�.�:*..�..*�*:**.*.+�**..*.�+.*.�+..**�.****+:*,»:*s*.***+*:*�**.****.�.*�*�.*..*.*.�*.*.*****.�:.�.*�.:...+� See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN A VANCE BY T PHON T 479-2149 OR AT OUR OFFICE FROM 8:00 AM� 4 PM. r 7 S��'' O�— S TURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNER ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B07-0260 as of 09-07-2007 Status: ISSUED ******************************************************************************************************** Permit Type: ADD/ALT COMM BUILD PERMT Applied: 08/07/2007 Applicant: TCD, INC. Issued: 09/07/2007 (970)453-3959 To Expire: 03/OS/2008 Job Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Parcel No: 210106325001 Description: TENANT FINISH WORK FOR THE BLUE MOOSE AT ARRABELLE ***********************************************Conditions:************************************************ Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ***********************************************+***********+******************************** TOWN OF VAIL, COLORADOCopy Reprinted on 09-07-2007 at 10:39:11 09/07/2007 Statement **+********�***+****�******+***********�****++*****��*******************************+*****�* Statement Number: R070001786 Amount: $2, 864.77 09/07/200709:44 AM Payment Method: Check Init: DDG Notation: Catskill Place Restaurant Co. 1501 ----------------------------------------------------------------------------- Permit No: B07-0260 Type: ADD/ALT COMM BUILD PERMT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $5, 339.77 This Payment: $2, 864.77 Total ALL Pmts: $5,339.77 Balance: $0. 00 *********************************************+******************************************++** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 2, 861.77 WC 00100003112800 WILL CALL INSPECTION FEE 3 .00 ----------------------------------------------------------------------------- � t ` � APPI.fi;AT10N WILL NOT BE ACCEPTED IF INCOMPLETE NSIGI �� ,,,\ Pr t�� ,����-_ � � Bu g 1�erm�#; _r' � � �' 97 � -2149 (Inspe tions) � '�4�iV 0�'Y�'I.' ` Q . v ' �I !'t�,G�C��. Fronta e Rd. � I 75 S. g ,,,�� Vail, Colorado 81657 TOWN OF VAIL BUILDING PERMIT A �1D1'm�� i/AIL Separate Permits are required for electrical, plumbing, mechanica , e c.. CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact Person and Phone#'s: TCD, Inc. 352-A Jim Anderson, 970.445.7245 Email address: janderson@tcdsummit.com Fax#: 970.453.3980 Contractor ignature j �' 2 Aug 2007 COMPLETE VALUATIONS FOR BUILDING PERMIT Labor& Materials ILDING: $ N/A ELECTRICAL: $ 92,225 OTHER: $ 209,260 PLUMBING: $ 55,225 MECHANICAL: $ 134,800 TOTAL: $ 491,510 For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com Parcel # Job Name: Blue Moose Job Address: 675 Lionshead Place #P170, Vail, CO Legal Description Lot: Block: Filing: Subdivision: Owners Name: Vail Blue Moose, Address: PO Box 5549, Beaver Creek, CO 81620 Phone: 970.845.0545 Brian Nolan Architect/Designer: Cahen Address: 7535 E. Hampden Ave#425, Denver, Phone: 303.743.0002 Architecture Group PC CO 80231 Engineer: KVA Consulting Address: 1100 W. Littleton Blvd #400, Littleton, Phone: 720.283.3018 CO 80120 Detailed description of work: Tenant Finish - Restaurant Work Class: New( X ) Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( ) Work Type: Interior(X ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( X ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family(X ) Commercial(X ) Restaurant( X) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( ) No ( X ) Does a Fire Sprinkler System Exist: Yes ( X ) No ( ) ***********************�:�*******************FOR OF FIC E US E ON LY�:��`*******'�'`�"`�"'"r�*'�`�"'`��*****'��**�'�"�� Date Received: Received By: C:\!TCD\Vail\building_permit_4-17-2007 moose.doc Page 1 of 4 04/17/2007 . - , � . 0 .' TOWNOF YAII,`. ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION • I have included the asbestos test and report with my building permit application applicant signature date OR • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be verified during plan review, and will delay your project if found to be inaccurate) applicant signature date OR • The building as con tructe after October 12, 1988. The date of construction was _ to be com lete Dece er 00 original construction date 2 2007 applicant signature date C:\!TCD\Vail\building_permit_4-17-2007 moose.doc Page 3 of 4 04/17/2007 424o Architecture Inc chicago denver 4240 July 31, 2007 Mr. Charlie Davis Town of Vail Chief Building Official Department of Community Development 75 South Frontage Road Vail, CO 81657 Re: The Arrabelle Building - Retail Tenant Improvements: "Blue Moose Pizza". Produced by Cahen Architectural Group P.C., 7535 East Hampton Ave., Suite 425, Denver, CO, and dated July 20, 2007. Dear Charlie: Pursuant to 2003 IBC Section 106.3.4, this is to inform you that 4240 Architecture, as the registered architectural design professional in responsible charge for the Arrabelle Project, has reviewed the above referenced proposed retail tenant improvement construction documents. To the best of our knowiedge, we find these documents compatible with the approved construction documents for the Arrabeile Project, with the exception of several issues requiring additional documentation by the tenant's architect as follows: • A 3"thick floor topping is required to meet finish grade at the entrance doors. The allowable load of the topping is limited to approximately 25 psf. The retail tenant architect should provide an addendum to the drawings providing a description of the proposed topping that falls within the load requirement. Options for this topping include, but are not limited to:: 1.) 3" `gyperete' or light weight concrete; or, 2.) 1 '/z" normal weight concrete on 1 �/2" rigid insulation. • Plumbing fixtures must be shown in Toilet Room 110. • Compliance with the minimum plumbing fixture count and fixture accessibility should be verified. Please do not hesitate to call should you have any questions. Sincerely, �.:°� ��,� '�J"� ���,S �i`:�'f ~�"�� . �;'� . 'k.,,"�„y'^°°r�++���Y! ��.� `.;. /�G.... ,y-'9'� � '� i ,� � � , � � �P ��ry.�� ` ; � 4..�. / ��.. `, 1 e; ? a. tr i,.�t `�.`�r+�'� � ' � �t� � �=-� :� E..:.� y;....' i E. Randal Johnson, AIA �'�;�'�?,ay Principal �,n:�`� ".°� .,` .s�' � r t ''"� Y �`:. � '� 4°��.1 ��j � �� � . - t62i Eighteenth Street Suite 20o Denver,Colorado 8ozoz T 303 29z 33$$ F 303 zgz 3ii3 W 4z4oarchitecture.corri **************************************************************�**************+************** TOWN OF VAIL, COLORADO Statement ***********+*************************************************************************�****** Statement Number: R070001456 Amount: $2,400.00 08/07/200703:06 PM Payment Method: Check Init: JS Notation: 1475/CATSKILL PLACE RESTAURANT CO LLC ----------------------------------------------------------------------------- Permit No: B07-0260 Type: ADD/ALT CONIM BUILD PERMT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $5,264.77 This Payment: $2,400.00 Total ALL Pmts: $2,400.00 Balance: $2,864.7'7 ******************************************************************************************** ACCOLJNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 327.18 PF 00100003112300 PLAN CHECK FEES 2,072.82 ----------------------------------------------------------------------------- � COMcheck Software Version 3.4.1 Lighting Compliance Certificate 2003 IECC Report Date:07/12/07 Data filename:\\Kvafs\kVA Consulting\Projects�2007-139Wdmin\Schedules\20031ECC-BlueMoose07-139.cck Section 1: Project Information Project Title: Blue Moose Pizza Construction Site: Owner/Agent: Designer/Contractor: The Arrabelle at Vail Square Carl Fretwell Vail,CO 81657 kVA Consulting 19590 East Main Street Parker,CO 80138 (303)646-4770 ca rf @ kva cons u Iti ng.net Section 2: General Information Building Use Description by: Project Type: New Construction Buildinq Tvne Floor Area Restaurant 4515 Section 3: Requirements Checklist Interior Lighting: � 1. Total actual watts must be less than or equal to total allowed watts. Allowed Watts Actual Watts Complies 7224 7184 YES � 2. Exit signs 5 Watts or less per side. Exterior Lighting: � 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings;signage;safety or security lighting;low-voltage landscape lighting. Controls, Switching, and Wiring: � 4. Independent controls for each space(switch/occupancy sensor). O Exceptions: Q•••••' . s� Areas designated as security or emergency areas that must be continuously illuminated. �;��• �'' F (�':'Q Lighting in stairways or corridors that are elements of the means of egress. r Q ��-m � 5. Master switch at entry to hotel/motel guest room. c�. 34235 r: v � 6. Individual dwelling units separately metered. � �� /� ��'... 1�(�;���c/ � 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. .(��:.,�'1 ;G�1 Exceptions: s ���""""'���J S��IVA�E Only one luminaire in space; An occupant-sensing device controls the area; The area is a corridor,storeroom,restroom,public lobby or guest room; Page 1 of 3 COMcheck Software Version 3.4.1 � Lighting Application Worksheet 2003 IECC Report Date: Data filename:\\Kvafs\kVA Consulting\Projects�2007-139Wdmin\Schedules\20031ECC-BlueMoose07-139.cck Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Watts I ft2 Restaurant 4515 1.6 7224 Total Allowed Watts= 7224 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Restaurant(4515 sq.ft.) Linear Fluorescent 1:A:2x4/48"T8 32W/Electronic 3 15 96 1440 Linear Fluorescent 2:A1:2x2/24"TS 17W/Electronic 3 1 54 54 Compact Fluorescent 1:D,D1:CF Downlight/Triple 4-pin 32W/Electronic 1 82 32 2624 Incandescent 1 copy 6:C:Decorative Pendant/Incandescent 150W 1 2 150 300 Incandescent 1 copy 1:F:Decorative Pendant/Incandescent 100W 1 12 100 1200 Incandescent 1 copy 2:P1:Decorative Pendant/Incandescent 100W 1 4 100 400 Incandescent 1 copy 2:P2:Decorative Pendant/Incandescent 50W 1 7 50 350 Incandescent 1 copy 3:T:Decorative Pendant/Incandescent 150W 1 4 150 600 Compact Fluorescent 2:WS:Decorative Wall Sconce/Triple 4-pin 18W/ 1 12 18 216 Electronic Total Actual Watts= 7184 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies. Total Allowed Watts= 7224 Total Actual Watts= 7184 Project Compliance= 40 . ^ p0 R ..FR /s►�F ��:m �'•� 34235 �' v �►��:. �`,��.:� �SS��V/VAI.ENG� Page 3 of 3 � � (�. ,� t�-- � ,�v� �,� � � �� �� � . � ���� '�� �, �" August 14,2007 � � Cahen Architecturai Group ; 7076 South Alton Way, Bviiding A ��'�� Centenniat, Coiorado,80112 Phone: 303.743.0002 Ft�x: 3�i.996A640 �"7� Q C��Q V Atht: Chad Wo�icrnorf Re: aiue Moos+e Pizza ��� The�IRCibeMe Bu�tg Qeor Chctd, Please note the following responses ta fihe review comments provided by the base building MEP engineer. �MIECHANICAL l,t Fhe make-up a�tiow rate in ttre ve�nti�rtiorr Schedule on FS 1 A tofic�ts 4152 CFM. The Mechonicarl Numbered nates on M2.0 totaf arnother�50 CFM of make-up aA►: The to#oi from both sheei�is 7.202 C�M. fi�base bu�ding de�gn a!located 6,200 CFM of mcike-�p a�to#his space. The makeup air unit serving 81ve Moose Pizua►also served oi`her tenantx in the builatFng,. It is nc�t accep�able to reduce c�flow fio it�e ofher#enon#s. fi+e rnc�keup oufffow Pate to the Bive M�Pizacr spc�ce sho�nc�t exc�d tttg attocc�ted 6,200 CFM. /ssue an crddendum ta adjust the moke-up c�f/ow rarte occardrngty►. Response: The venfiiatit�n schedule on sh�et FS i A is inctxrect and witl be modified to matd�the mechcynical drawings. The tota!rnake-up air tha# wiN be used for the sp(ace is 5.900 GFM. 1.2 Sheet fS6 strows f+��o up-E�ast fons and a m�ulce-up c�unit �e kitchen exhac�st fans ond marke-up a�unit a�e pravicied in ft�e base bu�ding systems Qnd do not need to be fumished by fhe tenvnt. Response:'fhe exhoust#ons and make-up air unit witl be removed from the kitchen a�ipmen#su�lier dre�wing s+�t. 1.3 Sheet M 1.t7 shaws o wart�r coofed conderuing vr�t prpiryg ctetc� The detoii indicates thot the piping to the conden�sing uniis wr�rvn wr�cl. Th�s is ncst accepi�a#�e. !�wa�teesr ccxrled candensing ur�fs ryre us�d d solenoid vc�lve confrol�ed by ffie condensing ur�t shall be installed to regulote flow to ecrch conder�ing unit. if the t�nant connec�s to the bas+e bui�ding 1l590 E�st AA�S�t.+l209 : Px�t�.Cc�tc�r,�r�o a0'i 3� : MMO�343.613.47Ta : �iR�t 3i13.4it.�Sb2� chilled woter system he shalt fwnish BFU meters on fhe chr�Ied water pipir� serving the condensing units. The food service plaru indicate that the watk in co+olers anri ice machines conder�sing urriis are o�-cooled. The discreperncy between fhe food service drawings and mechanical plans needs to be resolved. issve an addendum to m�fy the pla!ns acc+�rdingiy. Response: The sofenoid vc�tve to control the water flow to the condensing vni#s has been added to#he pfans. Sheet M1.0 dated 7-3i-07 shows this volve. The Icitchen equipmen#supplier clrawings w�t be reviseti#o mQtch the mecha�ical plans. 1.4 Sheet P2.0 has o note sfc�ting i�hot o i" 140 deg F domest�c�t woter iine wr11 be�xovided by the landtord. According to fhe Vai1 Resoris Development Compony the tandtord/tenont agreement does not state thQt i 40 deg F hof wvter wn7�be fumished to the sperce. The tenant shatt provide a boosfer hectter for the dishwasher to roise �lU deg F water to I�dsg F. �sue an cyddendum to adjust the pions vccor�aling�y. Response: A iarger baoster heater v�rt'N be specfied for th�c�shwa�her, and o ta�kiess electric water heater v�n't!be c�dded fcx the 3-compartment si�k#o accommodate the e�asting cond'rtions. Et,ECTRiCAL ].�4 E I OO:Indicc�te cvnduif and conductor s'rzes raeqv�ed fc�r the prim�y Qnd secondcay feeds of the tran�ormers. Response: The conduit and canductcx sizes wiN be ctec�rly identified in the Feeder and Transfc�rmer Schedules. l.5 F 1 U0:On the fe$der schedule, indicote oMy#he feeders being used. lt oppears only the new transfcxrner feeders wc71 be u�ed_ Response: Only fi�ansformer feeders ore�uRently used,th�s wiU be noted on the plans. l.6 E I.UO: Indicate only ths firansformer sizes t�ing used on fhe plar�s. Response: C?niy transfarmer used wiif be noted on the plans. 1.7 E2.U0: Fenant's con.sultant/eontracta�shcY/1 provide connecfion fvr(41 tan cor7 uniis per#he base bu+k�ing ele��ricoi documenfs. 7he fan coA units were installed by the base bviiding mechaRical confractor.. Refer to attached pian. i 4S9Q Ensr M�St�.#�Q9 : Pn�u�e,Cotot�oo 8t113Q: P�3Q3.+646.47T0 : F�ut 3�.6AdYS62S Response: �rowing will be revised to indicafe new connections as required once attached plan is received.Attoched pian was not included.lf possibie can you please send the missing attachment directly to cari@kvaconsultin .c� net.Thank you. 1959'0 E�sr IIM�Sn�#209 : P�t�Caow►oo s013a : Px�3ti3.blb.47T0 : F�c 303.br16.56?.3 i + CATOR,RU]VIA �7 ASSOC IATES, CO. ra�NC,PnLS CONSULTING MECHANICAL�ELECTRICAL ENGINEERS MICHAELA.MEINTS JouN A.HuctiFs BRUCEE.APPEL JAMES R.L�IZZERI MARCUSA.VAL[RIUS SENIOR AStiOCtATE MARK V.JELINSKE August 1�GOO/ ASSOCIATES SEAN I�.CONVERI' GER.4RD W.O'BRII;N DENNIS F.RUDKO W.�IYNEA.�I�RADER Mr. Charlie Davis Town of Vail Chief Building Official Department of Community Development 75 South Frontage Road Vail, CO 81657 RE: The Arrabelle Building: Blue Moose Pizza Cahen Architectural Group P.C. Permit Set dated 7/20/07 Mechanical/ElectricaUPlumbing Infrastructure Coordination Review CRA Project No. 2006-276 Dear Mr. Davis: Pursuant to 2003 IBC Section 106.3.4, this is to inform you that Cator, Ruma and Associates, as the registered design professional in responsible charge of the Mechanical, Electrical, and Plumbing design for the base building at Arrabelle, has reviewed the proposed remodeling of Unit 484/584 being submitted for a revision to the approved construction documents. To the best of our knowledge, we find the proposed revisions compatible with the approved construction documents with the exception of the items listed in the mechanical and electrical review comments attached to this letter. Please call if you have any questions or concerns. ������i,�;...,,, `��� "'•-. �• QO RE(ajs,'� Sincerely, `��� ��,, ...U,�. �'�'•. ��` � �.�� �y�' ATOR RUMA&ASSOCIATES, CO. � ;v0 t� �rs.�=�:_ ���� �E��s� , _ � 8 �_ ���.�,o��GLAS j°"F'QF� - �� 'w; ��' � 1�^ � • � • �.� ���� ��%��t���' �.�... '���� .s ,��,��,,����' ss•• , ���''� ��NAL��`'� �����•'� �ii������i� ���`1����` o,�.�,�, ,. ,\� A. Hughes, P.E. Hal Yoder, P.E. ELECTf�iICAL �'S;; , ' 'ncipal Mechanical Engineer M L HDY P:�.Amabelle�2007-146 Retail Tenan[Review Proposal\Sup\Docs\blue moose btdg dept ltr 080107.doc Cc: Steve Roberts—42/40 Architecture 1550 DOVER STREET•SUITE 2�LAKEWOOD,COLORADO 80215-3132 � PHONE(303)232-6200�FAX(303)233-3701 •E-MAIL:cra@catorruma.com Arabelle—Blue Moose Pizza Mechanical Peer Review Report CRA#2007-146 August 1, 2007 Cator, Ruma&Associates performed a peer review of the mechanical drawings completed by the owner's MEP engineer who will be providing their PE stamp on the drawings. The following review comments are intended to notify the owner of possible base building conflicts and impacts, as well as provide the Tenant Finish Engineer with a general review of their design. Note that the building deparhnent should review the drawings for code conformance. MECHANICAL l.l The make-up air flow rate in the Ventilation Schedule on FSIA totals 4152 CFM. The Mechanical Numbered Notes on M2.0 total another 3050 CFM of make-up air. The total from both sheets is 7202 CFM. The base building design allocated 6200 CFM of make-up air to this space. The makeup air unit serving Blue Moose Pizza also served other tenants in the building. It is not acceptable to reduce the airflow to the other tenants. The makeup airflow rate to Blue Moose Pizza shall not exceed the allocated 6200 CFM. Issue an addendum to adjust the makeup airflow rate accordingly. 1.2 Sheet FS6 shows two up-blast exhaust fans and a makeup air unit. The kitchen exhaust fans and makeup air unit are provided in the base building systems and do not need to be furnished by the tenant. 1.3 Sheet M1.0 shows a water cooled condensing unit piping detail. The detail indicates that the piping to the condensing units will run wild. This is not acceptable. If water cooled condensing units are used a solenoid valve controlled by the condensing unit shall be installed to regulate water flow to each condensing unit. If the tenant connects to the base building chilled water system he shall furnish and install BTU meters on the chilled water piping serving the condensing units. The food service plans indicate that the walk in coolers and ice machine condensing units are air cooled. The discrepancy between the food service and mechanical plans needs to be resolved. Issue an addendum to modify the plans accordingly 1.4 Sheet P2.0 has a note stating that a 1" 140 deg F domestic hot water line will be provided by the landlord. According to Vail Resorts Development Company the landlord/tenant agreement does not state that 140 deg F water will be furnished to the space. The tenant shall provide a booster heater for the dishwasher to raise 110 deg F water to 180 deg F. Issue an addendum to adjust the plans accordingly. HDY P:\Arrabelle�2007-146 Retail Tenant Review Proposal\Sup\Docs\Arrabelle blue moose PeerReview-mech 0801]07.doc Arabelle—Blue Moose Piza Electrical Peer Review Report CRA#2007-146 August l, 2007 Cator, Ruma&Associates performed a peer review of the electrical drawings completed by the owner's MEP engineer who will be providing their PE stamp on the drawings. The following review comments are intended to notify the owner of possible base building conflicts and impacts, as well as provide the Tenant Finish Engineer with a general review of their design. Note that the building department should review the drawings for code conformance. GENERAL: 1.1 In general, it appears there is a substantial amount of information missing that would be required by the building department. We have indicated some but not all missing information or required clarification on the electrical drawings, sheets E100, E200, and E300. 1.2 The drawings were reviewed for impacts on the base building electrical distribution system. 1.3 Refer to most current base building documents for requirements. ELECTRICAL 1.4 E 100: Indicate conduit and conductor sizes required for the primary and secondary feeds of the transformers. 1.5 E 100: On the feeder schedule, indicate only the feeders being used. It appears only the new transformer feeders will be used(see item#1.3). 1.6 E100: Indicate only the transformer sizes being used on the plans. 1.7 E200: Tenant's consultant/contractor shall provide connection for(4) fan coil units per the base building electrical documents. The fan coil units were installed by the base building mechanical contractor. Refer to attached plan. JAH/jah P:�Arrabelle�2007-146 Retail Tenant Review Proposal\Sup�Docs�Arrabelle blue moose PeerReview-Elec.0801.07.doc C:HRiSTOPHEf�1��ENG�S 17(l0 W. LittEeton Blvd.,su�te aQ� LiYtleton, Cotorado 80120 ENGINEEl��,INC. Ph(72D}283-3U18 Fax(720)283-5253 www.mengeseng.com � ,���,��,�;�..,.�..-'���.: Decemb�r 21,2007 ;-- . � Ntr.Sil!Ga�ison .��L_�;��. � ,° Envi�nmer�ta!Heaith C3tiicer, Planner TQwn of Vail : . . Vail,CO 81657 -� �ear Mr.Garison: T1ne purpose of this leiter is to verify ihe waier i�ea�er sizing f�r the alue Mc3ose an€�Cf�op Hause Restaurants aE ihe Arrabelte Buifding in Vail,CO. Each space is suppfied �vith water at 110 c�egrees �, therefore, the items that require 'i40 d2gree F �va�er (dishwashin�operations}are supplied thraug�an eiec;tric wafer heatcr t�at raises the temper�ut'e 3Q degr�e.s F_ The ca�culated�o�water i�ad��the Chap Ho�se restaurar�t dishwashing operatic�n is'I6t7.5 GPH,ca[culafed per the Golorada Re[ail Foad Establishment Ruies ar� Regulatiqns. The power reqr�ireci tc� r�ise the tem��rat�sre 30 ciegrees of tt�s flow rate of water is 40;091 Btu;hr. The specified electric water F�eater is Rhees�rr�odel E�-50-12-G; uvt�ich has a recovery capacity of 4�;944 Btu/t�r('f2 kW}. The derr�anci is g8% Qf the water heater capa��#y, so the specified tivater hea#er is suffieient f�r this ap�aEicat"ran. The calcutated hot water€oad forihe 81ue Moose restaurar�t disf�washing aperaiian is 12Q.5�PN, calc�lated per the Col�rada Retaii Foed Estabtishmenf Rules an� REgulatians. The power required to €ai5e the temperature 30 dQgre�s far this fl�w rate of water is 30,094�tu/hr. The speeifte�i electric water heater is Rh�ecn model ES-5(?-12-G, �,vhi�h ha5 a recovery capaaty of 40,944 Btu/hr(�2 kW). The derriand is 74%4f the water heater capacity, so the speci�ied water heater is sufficier�t for this ap�lication. Sincerely, f��"�`---'" Z''�� o G . �. Ch�is#apiter Menges Pr�sident TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT ?5 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A07-Ol 14 Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: ARRABELLE HOTEL-Blue Moose Applied . . : 10/OS/2007 Parcel No...: 210106325001 Issued . . . 10/11/2007 Project No : Expires . .: 04/08/2008 OWNER ARRABELLE AT VAIL SQUARE LLC10/05/2007 PO BOX 7 VAIL CO 81658 APPLICANT COMMERCIAL SPECIALISTS OF 10/05/2007 Phone: 970-513-'7100 WESTERN COLORADO, LLC P.O. BOX 1572 SILVERTHORNE CO 80498 License: 161-5 CONTRACTOR COMMERCIAL SPECIALISTS OF 10/05/2007 Phone: 970-513-'7100 WESTERN COLORADO, LLC P.O. BOX 1572 SILVERTHORNE CO 80498 License: 161-5 Desciption: BLUE MOOSE AT ARRABELLE- Installation of smoke detectors, heat detectors, strobes and speakers strobes Valuation: $12,201.00 +**+��+***��**+►+*�*��*►��***��:+*►**a***s*�*►r*:r+*��*+*******��***** FEE S UMMARY ****�*+as***�x��«�:******rts*r*r***+*****�►*+*****r*+►**+r�*+ Electrical---------> $0.0 0 Totai Calculated Fees--> $6 8 9.54 DRB Fee---------> $o.00 Additional Fees----------> $0.00 lnvestigation----> $o.oo Total Permit Fee--------> $689.54 W ill Call---------> $o.0 0 Payments------------------> $6 8 9.5 4 TOTAL FEES--> $6 8 9.54 BALANCE DUE--------> $o.o 0 .r**r+rs+r******++**+++*+sr****+►►*►*�**►*►�**s��.�r*.�*�s►r*:**++**�+*r*r***�*►*r+***+**r*�*�*►+��+*�*�***s**+�*s**«r�r*+*****�+*�+�:*a***.***rxas Approvals: Item: 05600 FIRE DEPARTMENT 10/08/2007 mcgee Action: AP Add manual pull station in kitchen. *�.*.**.******.*.*.***.*...***.**.�...�..*...�.«*:***�*****.*.**....*.**�.*..*.*.*.*...*.*:.�..*...�.*.***.*.*�*,:.*.*.��.*.*s.*.�.*��..�*.*,*.�,:* CONDITIONS OF APPROVAL .���****.*�**.*�.�,.*.��*.*......�.........*.*.*.*.*.***..*****,...�.*.*.**.*.*,:�*�*«*�******.*.�*.*.*.***.*.��*,:.**.,*,**�*****.*.**.�.******.*. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-Z135 FROM 8:00 AM-5 PM. \��"vJ �\�-�-�---�-_ .`_ C-C��'`% � . � � *+*****************************************+**************************************+********* TOWN OF VAIL, COLORADO Statement *****************************+***********************************+**************�*********** Statement Number: R070002175 Amount: $689.54 10/11/200708:37 .AM Payment Method: Check Init: DDG Notation: Commercial Specialists 10825 ----------------------------------------------------------------------------- Permit No: A07-0114 Type: ALARM PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL - Blue Moose Total Fees: $689.54 This Payment: $689.54 Total ALL Pmts: $689.54 Balance: $0.00 ******************+************************************************************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 FIRE ALARM PERMIT FEES 457.54 PF 00100003112300 PLAN CHECK FEES 232.00 ----------------------------------------------------------------------------- TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E07-0224 �; �1 -02� U Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: BLUE MOOSE @ ARRABELLE HOTEL Applied . . : 09/14/2007 Parcel No...: 210106325001 Issued . . . 09/14/2007 Legal Description: S.�-s.�S� � _v �J Expires . .: 03/12/2008 Project No : OWNER ARRABELLE AT VAIL SQUARE LLC09/14/2007 PO BOX 7 VAIL CO 81658 APPLICANT DESIGN ELECTRICAL CONTR.ACTOR09/14/2007 Phone: (970) 468-5330 7193 S. DILLON COURT ENGLEWOOD CO 80112 License: 352-E CONTR.ACTOR DESIGN ELECTRICAL CONTR.ACTOR09/14/2007 Phone: (970) 468-5330 7193 S. DILLON COURT ' ENGLEWOOD CO 80112 License: 352-E - --�..,'� Desciption: ELECTRICAL F R BLUE MOOSE AT A ABELLE Valuation: $80,000.00 --� quare feet: 0 ******************************************************************* FEE SUMMARY ******************�*******************s********************� Electrical---------> $1,713.50 Tota1 Calculated Fees--> $1,717.50 Invesdgation----> $0.00 Additional Fees----------> $0.00 Will Call---------> $4.00 Total Permit Fee--------> $1,�17.50 TOTAL FEES--> $1,717.50 Payments------------------> $1,717.50 BALANCE DUE--------> $o.o0 ***�****************************�*a:*�***�*************************�**********s****************************�**�:*********************************** Approvals: Item: 06000 ELECTRICAL DEPARTMENT 09/14/2007 shahn Action: AP ******�:****************************************�******�*«************��:*�***�*****************************************�************************* CONDITIONS OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *********************************************************************�***********************************************************************�*** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. ' . � ��, , ,, � � . SIGN T OF OWN R ONTRACTOR FOR HIMSELF AND OWNEF **************************************�***************************************************** TOWN OF VAIL, COLORADOCopy Reprinted on 03-23-2009 at 13:23:35 03/23/2009 Statement ******************************************************************************************** Statement Number: R070001864 Amount: $1,717.50 09/14/200702:37 PM Payment Method: Check Init: JS Notation: 28816/DEC ----------------------------------------------------------------------------- Permit No: E07-0224 Type: ELECTRICAL PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: BLUE MOOSE @ ARRABELLE HOTEL Total Fees: $1,717.50 This Payment: $1,717.50 Total ALL Pmts: $1,717.50 Balance: $0.00 ******************************************************************************�x************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 1,713 .50 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UN �� _ V �� � Project#: Building Permit � � � � 7 � _ � ��i" ��� � �"� Electrical Permit#: � - " � ���'�'"'��� ' 970-479-2149 (Inspe �ons 75 S.Frontage Rd. Vail,Colorado 81657 �T WN OF VAIL ELECTRICAL PERMIT APPLICATION � � � � l � � CONTRACTOR INFORMATION �lectrical Contrs� or:_. Town of Vail Reg. No.: Contact Per n and Phone #'s: : '��I�d � ��' ��,�y-- � �' / ' � � ! I` �,�► ) E-Ma Address: Fax#: � Co tra�c�c�r Signatu�e: �' �� _ �i � � � / �� / O�PLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor&Materials) AMOUNT OF SQ Ff IN STRUCTURE: ELECTRICAL VALUATION: $ �} } 1 � ��(� Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www,ea le-coun ,com fo�Parce/# Parcel # Job Name: �' �/ ���'�f�' �� Job Address: !1� f�.,��� ^�, Legal Description Lot: Block: Filing: � Subdivision: Owners Name: Address: Phone: Engineer: Address: Phone: � Detailed description o�work: � ��,�`i f��`���"�°v������'� TI' Work Class: Ne Addition ( ) Remodel ( ) Repair( ) Temp Power( ) Other( ) • Work Type: Interio Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family( ) Duple�c( ) Multi-family( ) Commercial( ) Restaura Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes( ) No( ) (� �G �:,r, �u� r_ �l � �� . �� �*��������**�*��������*���***��**����**FOR OFFICE USE ONLY��� �*�*���*���*�*������r�r �r��*�*� SEP 13 2007 �.�iier..Fe�»..��. �s _Da�Received .— E�RB$ "'� ' ,: AaG� �B � Rg- :�� �>�s. ' � Al�. �►ar�n+en,�i rt-o�F. ..a_.._r � F:\cdev\FORMS\PERMITS\Building\electical�ermit 11-23-2005.DOC Page 1 of 2 11/23/2005 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F07-0139 Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: ARRABELLE HOTEL Applied . . : 10/18/2007 Parcel No...: 210106325001 Issued . . . 12/06/2007 Project No : Expires . .: OWNER ARRABELLE AT VAIL SQUARE LLC10/18/2007 PO BOX 7 VAIL CO 81658 APPLICANT TRI COUNTY FIRE PROTECTION 10/18/2007 Phone: cell 303-591-3111 PO BOX 309 RIFLE CO 81650 License: 727-S CONTRACTOR TRI COUNTY FIRE PROTECTION 10/18/2007 Phone: cell 303-591-3111 PO BOX 309 RIFLE CO 81650 License: 727-5 Desciption: INSTALLATION OF KITCHEN HOOD FIRE SUPPRESSION SYSTEM FOR THE BLUE MOOSE AT ARRABELLE Valuation: $2,650.00 s*s**rr*a�*�+******�*++����*���*+**+*�******«*r*t+*►r►*+«**+**�+*r*• FEE S UMMARY **:t*rs*s*r�****�********sx**v***s*****+r+r*****+****��sr�**a Mechanical---> $0.oo Restuarant Plan Review--> $o.00 Total Calculated Fees---> $462.63 Pian Check---> $3 5 0.o o DRB Fee---------------------> $o.0 0 Additional Fees-----------> $o.0 0 Investigation-> $o.oo TOTAL FEES--------------> $462.63 Total Permit Fee----------> $462.63 Will Call-----> $0.D 0 Payments-------------------> $4 6 2.6 3 BALANCE DUE---------> $o.o 0 +***.**�**►+�*�+.�.**++r:«*.**r■***.*�.*.***s.s**��+.»»*�*s**.*■.■.*:*.�:.***.*..*.■��.s*�►.***s.►**«�*�s��r*■�*s*+*+**.*.*.*.**►+►*�st�+�++*s***+� Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 10/25/2007 mvaughan Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *.**.**��.****���********:.****r�***�.**��..*.:►*«*:�******.+.�,:.**+*.*...«�*�►***��*.,*+«�*.**�*.*���*+*�*.�*�....+�*.**�.*.*****«**+*:�....*�.* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FO, fJU S I ADVANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM. ' ` � G SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ********************************************++*************************************+******** TOWN OF VAIL, COLORADO Statement **************++**�**********************�**�*********************+*****+*********+********* Statement Number: R070002659 Amount: $462 .63 12/06/200709:50 AN[ Payment Method: Check Init: DDG Notation: Tri County Fire Protection 505 ----------------------------------------------------------------------------- Permit No: F07-0139 Type: SPRINKLER PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $462 .63 This Payment: $462 .63 Total ALL Pmts: $462 .63 Balance: $0.00 ************************************************�******�+�******�*�***************�********* ACCOUNT ITEM LIST: Account Code Description Curi-ent Pmts -------------------- ------------------------------ --�--�-------- BP 00100003111100 SPRINKLER PERMIT FEES 112.63 PF 00100003112300 PLAN CHECK FEES 350.00 ----------------------------------------------------------------------------- . TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMF;S SPRINKLER PERMIT Permit #: F07-0116 �G � - C�.�taU Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: ARRABELLE HOTEL Applied . . : 09/26/2007 Parcel No...: 210106325001 Issued . . . 10/08/2007 Project No : �-��j� -G;j�� Expires . .: OWNER ARRABELLE AT VAIL SQUARE LLC09/26/2007 PO BOX 7 VAIL CO 81658 APPLICANT ALL STATE FIRE PROTECTION, I09/26/2007 Phone: 303-288-3901 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370-S CONTRACTOR ALL STATE FIRE PROTECTION, I09/26/2007 Phone: 303-288-3��01 6045 E 76TH #12 COMMERCE CITY CO 80022 License: 370-5 Desciption: BLUE MOOSE AT ARRABELLE-INSTALL FIRE SPRINKLER SYSTEM Valuation: $13,000.00 ****��*****�***��:*******s*a***�**********+*+�****+�*****a***�****+*■ FEE SUMMARY �*�*�***«****�*r****t***t***,�************�****+***r*�***t*** Mechanical---> $0.00 Restuarant Plan Review--> $0.0 0 Total Calculated Fees---> $902.5 0 Plan Check---> $3 50.o o DRB Fee---------------------> $0.0 0 Additional Fees-----------> $0.0 0 Investigation-> $0.00 TOTAL FEES--------------> $902.50 Total Permit Fee----•-----> $902.50 WiIlCall-----> $0.00 Payments-------------------> $902.50 BALANCE DUE---------> S o.o 0 +***�:+**trr**�*r*****t***�***»�*►**�**�**t***s►*t*�*t*�*t*��r******v**rt**+**+****s+**�+r******«**+*********�***+****�:**�+*rx�*r********�s**�+*** Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 10/04/2007 DRhoades Action: AP Approved as noted: 1 . Location tor control valve tor this space must be approved by Vail Fire prior 1 installation. CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE;. ***■**■*.****.***«**......:*«.«*.*,�+*.**.*.*■�.*■*.*:*.*.+*..:..*********»**.****..*.*■*■*■:■**■*.s*.*�******�.*.*.*..*�...***..**.*.*�■*.*.*■*:� DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, com��leted an accurate plot plan, and state that all the infarmation as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable tlhereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV NCE B T �EPHONE AT 479-2135 FROM 8:00 AM-5 PM. . ��' �, -...' SIG ATURE OF OWNER O ' ONTRACTOR.FOR HIMSELF AND OWNER ******************************************************************************************** TOWN OF VAIL, COLORADO Statement *******************************************************************************�************ Statement Number: R070002126 Amount: $902 .50 10/08/200712 :45 Pb1 Payment Method: Check Init: LT Notation: All State / ck 15825 ----------------------------------------------------------------�-- ----------- Permit No: F07-0116 Type: SPRINKLER PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $902 .50 This Payment: $902.50 Total ALL Pmts: $902 .50 salance: $0.00 ***************************************+***************************************�************ ACCOUNT ITEM LIST: Account Code Description Cur��ent Pmts -------------------- ------------------------------ -�--�--------- BP 00100003111100 SPRINKLER PERMIT FEES 552 .50 PF 00100003112300 PLAN CHECK FEES 350.00 ------------------------------------------------------------------ ----------- APPLICATION WILL NOT BE ACCEPT D IF INCOMPLETE OR UNSI ���_`,�,�� � Project#: Building Permit#: _ � Sprinkler Permit;�: ,� 970-479-213 !ns tio s `' TOWN OF VAIL FIRE SPRINKLER PERMIT APPLJCATION TUWNOFYAIL Fire Sprinkler shop drawings are required at time of permit siabmittal and 75 S. Frontage Rd. must include the followi�g. Permit application will not be ac�;epted Vail, Colorado 81 without this information: • A Colorado Registered Engineer's stamp or N.I.C.E.T.. Level Iil (min) stamp, • Equipment cut sheets of materials. )%� • Hydraulic calculations. � • A State of Colorado Plan Registration form. • Plans must be submitted by a Registered Fire Proxecl:ion Contractor. CONTRACTOR INFORMATION �„ �ire Sprinkler Contractor: Town of Vail Reg. No.: Contact and Phone#'s:� � � �1°��; ._� ��i�—�'. �i'�Li:�Tr�! ti<-`': `�C��?'Y.�>�'->F'e �4 E-Mail Address: i'1���1�� �l 1 S+e:�-��r�`"ro�trCfr�c;�'� �'`�"� -----------��_W..�� 7� Contractor Signature: r ,(� �f�,� , i '�� ,�-1C,t�2,�d�< ��C2���:��l.a� __�_.�J COMPLETE VALUA710NS FOR ALARM PERMIT (Labor& Materials) Fire Sprinkler:$ �,� ���• �.�J Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea !e-counf .com for Parcel# €�arcel # � Job Name:;� }^ t � y /� /�� Job Address �,���' a�,,/� j/�7�:,�t)� `�!`• ��� ¢�' ' � �Z��ti+C���C. � �LZ�� �� �•^�rG(�JC�Iy� 1Y/' tl� f ...�✓,. S/ � ' � _��-__'_ __��A` Legal Description Lot: Biock: Filing: Subdivisior: T�__ � _M_.__�_.��-�i �wners Name: i�,, �� Address:�� �: � ��, � CO �;t��� Phane:...����' � l�� _G�.j�-`'_V_.�..�i -± �.CY � '" _� Engineer: Address: Phnne: �._...�. _ ---�-=�-—�� Detailed Location of work: (i.e.,floor, unit#, bldg.#) �� 1�"- � f ls5 . . —_—_. .. - .-.;-�i Detailed description of work: � �� �'���tid d �1i� e �J`J6'�a:'?���+'r _ e �j � --- -----._._------''-,:�i a� �Nork Ciass: New( ) Addition ( ) Remodel ( ) Repair( ) Retro-fit( ) Other( ) � ___ ^ �j 7ype of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( } Restaurant( ) Other( }� �� No. of Existing Dwefling Units in this building: No.of Accommodation Units in this building: 1 Does a Fire Alarm Exist: Yes( ) No ( ) Does a Fire Sprinkler System Ex�st: Yes ( ) No( ) *::**********�***�*****,�***�************FOR OFFICE USE ONLY*****************�k******��*�x*:r�*�*** �.Other F�es, ' � k ��� F,ub�cr . ����er .�ft��e���s� � �:;:�� � � , F , �w. . � n�:, �O�ct� anc ��ou �' � �'s ��� �� � ,��= ` � � P Y` P� \��'ait\data\cdev\FORMS\PERMITS\SPRKPERM.DOC --_ ����4�7iI�'lLV"L,����xY�� '�'�C .��.(�'��.�.1�,�:�.�r'��.o...�a.....n,_.e..e.a....._�..�._,. D�te: _�.�fl-DY-D'7 �...�.�.�.�v..�:�.. TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M07-0256 Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: ARRABELLE HOTEL Applied . . : 10/02/2007 Parcel No...: 210106325001 Issued . . . 10/04/2007 Legal Description: Expires . .: 04/O1/2008 Project No : OWNER ARRABELLE AT VAIL SQUARE LLC10/02/2007 PO BOX 7 VAIL CO 81658 APPLICANT COMMERCIAL DESIGN ENGINEERINIO/02/2007 Phone: 970-245-0595 PO BOX 2440 COLORADO SPRINGS CO 80901 License: 192-M CONTRACTOR COMMERCIAL DESIGN ENGINEERINIO/02/2007 Phone: 970-245-0595 PO BOX 2440 COLORADO SPRINGS CO 80901 License: 192-M Desciption: BLUE MOOSE AT ARRABELLE TENANT FINISH Valuation: $9,750.00 Fireplace Information:Restricted: #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0 ���*�s******r**►*****a�+****�*�**r**+�*+*r*+*a****�+*+*�**�**t***r*r FEE S UMMARY •*�***swt*�**************►***�*�**v**+***+****►***�:++�***r�+ Mechanical---> $200.00 Restuarant Plan Review--> $o.00 Total Calculated Fees---> $254.00 Plan Check---> $5 0.o o TOTAL FEES--------------> $2 s 4.o o Additional Fees-----------> S o.o 0 Investigation-> $o.o o Total Permit Fee----------> $2 5 e.o 0 W ill Call-----> $4.0 0 Payments-------------------> $2 5 4.o 0 BALANCE DUE---------> $0.00 *�*v*s+*«►*******s***►s*******r****+****r***�*s**�r*�*****■**«****r►+�r*t+►w+****r*►+**��►****��**r*sr+*«�*+**a**„.*+*�*r**�*******s*s++�*****��*+ Item: 05100 BUILDING DEPARTMENT 10/02/2007 cgunion Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG. ) : COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AN:D SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. � Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCI'IONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF �HE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. . Cond: 31 (BLDG. ) : BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONS�. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG. ) : PERMIT, PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHE3R APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 . 6 . *+*».*+�.+s...*.***:**.*.*.*►**.*.*+*+.**...+..►*.*.*�+*..«...*.*.***.*.��.*.*�*�**.***.****►*.*�.*++.+*..*.*.».*.�+s.******.*rs***:+�.*.�*:.**.* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, connpleted an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordi nces of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVA E B TELEP AT 79-2149 OR A7 OUR OFFICE FROM 8:00 AM-4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER *++****+************************�*********************************************************** T0�1VN OF VAIL, COLORADO Statement ***************************************+*+************************************************** Statement Number: R070002079 Amount: $254 .00 10/04/200708 : 18 .AM Payment Method: Check Init: DDG Notation: Commercial Design Engineering 095470 ----------------------------------------------------------------------------- Permit No: M07-0256 Type: MECHANICAL PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $254.00 This Payment: $254 .00 Total ALL Pmts: $254 .00 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 200.00 PF 00100003112300 PLAN CHECK FEES 50.00 WC 00100003112800 WILL CALL INSPECTION FEE 4 .00 ----------------------------------------------------------------------------- 10/Ol/2007 11:35 FAT 9702451015 �006/006 APPLICATION WILL NdT BE ACCEPTED IF INCOMPLETE OR UNSIG �f ��? �3�� TOV Project#: "V Building Permit #: Y ;• � b Mechanical Permit#: � � � � 970-479-21�49 Ins ections ����� ( P ) TOWN OF VAIL MECHANICAL PERMIT APPLICATION �5 s. Frontage Rd. Permit will not be accepted without the following: vaiy Colorado 81657 Provide Mechanital Room Layout drawn to scale to include: / o Mechanical Room Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue,Vent and Gas Line Size and Location � o Heat Loss Calcs. o Equipment Cut/Spec Sheets CONTRACTOR INFORMATION Mechanical Contractor: Town of Vail Reg: No.: Contact Person and Phone#'s: co — �9 z � c �9 4qz- E-Mai1 Address: Fa�c#: Contractor Sigr�ture: COMPLETE VALUATION FOR MECHANICAL PERMIT Labor&Materials MECHANICAL: � SD Contact Ea /e Coun Asse�sors�Ce at 7 -328- 640 or visit www,ea le-coun ,com fnr Parrce/�# Parcel # 210/O Job Name: Job Address: �t !.0 E Mao.s�. �0 7 �.io he l% ��� Legal Description Lot: Block: Filing: Subdivision: owners Name• �G�k / Addrass:b�5 L�onsfic lQ . P/3 Pf1On�'7o 32 I� Engineer: Address: Phone: Detailed description of work: rENR�r.►-l' �/1�3{� work Class: New ( ) Addition ( ) Alteration�[) Repair( ) Other( ) Boiler Location: Interior( ) Exterior( ) Other( ) Does an EHU exist at this location: Yes ( ) No( ) Type of Bldg: Single-family( ) Duplex( ) Multi-family( ) Commercial( ) Restaurant( ) Other( ) No. of Fxisting Dwelling Units in this building: No.of Accommodation Units in this building: No of Fire aces Existin : Gas A liances Gas L s Wood Pellet Wood Burnin No/Type of Fireplaces Proposed: Gas Appliances( ) Gas Logs( ) Wood/Pellet( ) Wood Burning(NOTALLOWED) Ls this a conversion from a wood buming fireplace to an EPA Phase II device? Yes ( ) No ( ) ************************FOR OFFICE USE ONLY*********************'� : ...._...... ........... .. .. ...._......._:::.�::;:�� �p I� �O e+.:.. ; . � -.. .Cy�iai?:Rec�iVi�::�::�:i�;�:����:�:::'-=?:�:: !s ..:#h:..:�r:_�ees;;>;;�_<:�:::'=>'�:�';;::=:_:::::�:................._........._........._................_......__-............. '��'::: G, � � \v� _........:....:.�,:..._..................................................::::::-_:::.::r:�.::::��.._... L. ::::::�::::::::::.::::::::::�-_,_-:,,�:::�:::-.::�... ......._............_................................. .............._....,._........,... :,::,., ::.:: :.,::.-:,.-. _...:..:::::::.::::::.-:.:.:::.:....:......_..............._...,., , .. ........._.;.....:.: ...._._:..::::. .::::::::...::.:.:..::...::..:::::::::.::::.::::::��:::�,:.Ac�� ,�,it;B. ._::-�:::s:�'::;:;;:;;:;::�::�:::::::;:.;:;,::;.s:: .. ,. . . ::.�::::;::�;�;.:.:..:.::::::: .:::."=°''�:::t;:s;:;::s;:::_:::-;:'::.::-s�:-::::�:�a:;::::-:.�:�.::-:t�:;;:;;::::;;::;�;;;t::':::> -:_.: ��� �� 1 Z�fl� F:\cdev\FORMS�Permits\Building\mechanical_permit_il-Z3-2Q�5.DOC � 11/23/2005 S TOWN OF VAIL TEST, ADJIJST A►ND BALANCE REPORT PROJECT BLUE MOOSE PIZZA ELLE VAIL, CO PREPA�RED FOR CDE MEC�:[��.NICAL REPORT ISSIJE DATE 12/27/2007 PREPA►_R.ED B� H-VAC P O. BOX �123 VAIL, CO 81658 PHONE: 970-331-1095 FAX: 970-926-9406 � H-VAC TEST.ADJUST AND BALAN�E REPaRT THE DATA PRESENTED IN THIS REPORT LS AN EXACT RECORD OF S�STEM PERI�ORMANCE AND WAS OB'I`AINED IN COMPLIANCE WITH NEBB PROCEDURAL STANDARDS. ANY VARIANCES FROM THE DESIGN REQUIREMENTS ARE NOTED THRQUGHOUT THIS REPORT. THE RESULTS SHOWN AND INFORMATION PRESENTEU IN THIS REPORT LS CERTIFIED TO BE ACCURATE AND COMPLETE,TO THE EXTENT POSSIBLE BY EQUIPMENT AND PR4CEDURES USED THR4UGH- OUT THIS SURVEY. THE FINAL AIIt DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NEBB PROCEDURAL STANDARDS FOR TESTING, A.DdiJSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY: _ DATE: �—��� THE FINAL HYDROI�IIC DISTRIBUTION SYSTEM MEASUREMEIV'TS ARE Il�T COMPLIANCE WITH NEBB PRUCEDURAL STANDARUS FOR TESTII�tG,ADUSTIl�TG AND BALANCIl�tG OF ENVIKONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY• DATE• H-VAC WARRNATS THAT TI-�AIR AND HyDROAIIC SYSTEM EVALUATED DURING THIS SURVEY IS OPERATIl+iG AT THE SPECIFIED LEVELS AS SHOWN WITHIN THIS REPORT,AT AND ONLY AT THIS TIME. H-VAC MAKES NO OTI�R WARitANTIES,STATED�R IMPLIED,CONCERNiNG THE CONfIUED PERFORMANCE,OPERATION OR SAFETY IN THE USE OF THIS EQIJIPMENT PASS THIS TIME. �.�/4� T•A•�• Page: I co��a a . �'�iqa �.,t,a4Q H-\/AC nvs�xvMErrr CALIBRATION REPORT PROJECT: �v�a�3F1... INSTRUMENT/SERIAL# APPLICATIQN DATE OF USE CALIBRATION DATE SHORTRIDGE ADM-870/M91519 AIR FLOW READINGS 12/27/0� 4-27-07 SHORTRIDGE I�M-300/WO1115 WATER PRES.READTNGS 427-07 SHORTRID('E FLOW HOOD AIF FLOW READINGS 12/27/07 * PITOT TUBE 18" PRES.READiNt3S NA PITOT TUBE 24" PRE�.READINGS NA PITOT TUBE 36" PRES.READINGS NA SHIMPO TACHOMET'ER/B54139Q 18 RPM READINGS 12/Z7107 4/18/07 FLiJKE 32/52t01005 VOLT/AMP i2/27/07 4-25-07 DAVIS LCA 6000 AIItFL.OW READINGS 12l2710? 425-2007 TEST GAGE 0-S LBS WATER PRES.READINGS * TEST GAGE 0-20 LBS WATER PRES.READINGS * TEST GAGE 0-68 LBS WATER PRES.READINGS * FLLlKE 62 INFARED TI�RM. TEMP.READINGS 3-20-07 'CHECK6D TO CAWBRATED METER REMARKS: ALL READIIJGS WITH SHORTRIDGE INSTRUMEIVTS ARE CORR�GTED F�R TEMPERATURE AND ALTiTUDE. PAGE: H-V�4►C I�TCHEN HQUD T�EST REPUIt.T REPORT: BT.T iF M CF pT7.7 A LOCATI�N: pT77 A nVFNS DATE: _�'�����m , TYPE: CLIENT: t�nF�,rFrI-iA�iICAL MFG: �APTLYF nTUF ADDRESS'ARR AR�'T T F.—VAiT t''t� SERIAI.: C�E"i�4 ND-� ATTN: EQUIP ID_ GREAS� FILTER INTAKE VELOCITY READINGS 143 220 148 165 i62 155 151 166 ��IRFLOW DATA AVERA(iE C3REASE FILTER VELOCITY 164 GREASE FILTER AREA FACTOR 10.7 MEASLTREI3 TOTAL EXHAUST CFM 1754 DESIGN T�TAL EXHAUST CFM �gpp MEASURED TOTAL MAKE UP AIR CFM 917 DESIGN'ii0Tt1L MAKE UP AIlt CFM 9QQ SMOKE TEST RCSIILTS PASSED MANUFACTURER MODEL TEST'PROBE SHORTRIDGE ADM 870 VELGRID PAGE: I ����� KITCHEN �I40D TEST REPUR�' REPORT: Rt.{TF M['N)�F Pi77 A LOCATION: xi'rru�N t.TNF DATE: ��?���� . TYPE: CLIENT: .S'I�MEC.N�iIICAi MFG: CAPTIVE AIFtE ADDRESS� ARRABET LF SERIAL: �4�4 NU-� ATTN: EQUIP ID: GREASE FILTER INTAKE VELOCITY READINGS 216 193 202 192 1'I8 186 202 188 201 194 ow n Ta AVERAGE GREASE FII,1ER VELOCiTY 196 GREASE FILTER AREA FACTOR 16A MEASURED TOTAL EXHAUST CFM 3136 DESIGN TOTAL EXHAUST CFM 3200 MEASURED TOTAL MAKE UP AIR CFM 1577 DESIGN TOTAL MAKE UP AIR CFM 1600 SMOKE TEST �..sUL1's PASSED MANUEACTURER MUDEL TEST PROBE SHORTRIDC',�E ADM 870 VELGRID PAGE:2 � H-�AC AIR APPARATUS TEST REPORT PRQJECT:BIUE MOOSE PIZZA ARRAREL.LE UNiT: D'!-01 AIR HANDLER UNtT DATA MUTOR NAMEPLATE DATA MANUFACTURER IEC MANUFACTURER BALDt�R MODEL HBC1200051645 HP R.P.M. 1/2 1725 SERIAI_ 961455-10-2 PHASE FRAME 1 56 FAN TYPE CENTRIFUGAL S.F. TYPE 1.25 NG RI4TING 1000 CFM VOLTS AMPS 115 l 230 8.4/4.2 MIN OSA 700 CFM THERMALLY PROTECTED YES STARTER DATA DRIVE DATA MANUFACTURER NC1NE MOT�t ORNE '! VP 325"4D MODEL MOTOR B4RE 1/2" Sie!E/THERMAL NO. FAN DRtYE 1 AK 54 RANGE FAN BORE 3i4" SET AT(AMPS} .BELTS�SIZE 1 �A25 REQ.THERMAL ROTATIt�N CORRECT RATING(AMPSj DRNE CHANGE AIRFLOW DATA TEST DATA lNIT1AL FINAL SUPPLY CFM 107& FqN R,p�. g� OSA CFM 721 VOLTAGE �2p RETURN CFM 355 AMPERAGE 7.9 ATMOS FILTER COIL -0.41" r� �12„ NOTES: PAGE: � H-a/AC AIR APPARATUS TEST REPORT PROJECT:BLUE MOOSE PIZZA ARRABEILE UNIT: D1-03 , I41R HANDLER UNtT DATA MOTQR NAMEPWTE DATA MANUFACTURER IEC MANUFACTURER BALDOR MODEL HBC200005i648 HP R.P.M. 1 1725 SERIAL 961455-50-2 PHASE FRAME 1 56H FAN TYPE CENTRIFUGAL S.F. TYPE 1.15 NG RATING 20q0 CFM VOLTS AMPS 115/230 13.4/6.7 THERMAi.LY PROTECTED YES STARTER DATA ORNE DATA MANUFACTURER NONE INOTOR ORNE 1 VP 3.25"O� MODEL MOTOR BORE 5/8" ' SIZEITHERMAL NO. FAN DRNE 9 AK 54 RANGE FAN BORE 3/4" SET AT{AMPS} .BEi.TS 8�SIZE 1 �i A28 REQ.THERMAL ROTATlON CORRECT RATING(AMPS) DRNE CHANGE - I AIRFLOW DATA TEST OATA INITIAi. FINAL SUPPLY CFM 2Q47 FAN R.P.M. 897 OSA CFM 0 VOLTAGE 120 RETURN CFM 2047 AMPERAGE g.1 ATMOS FILTER COIL -0.48" rJ �09„ NOTES: PAGE:2 H•VA►C A!R APPARATUS TEST I�EPORT PROJECT:BLUE M4QSE PIZZA ARRABELLE UNIT: D'!-05 AIR HANDLER UNtT DATA MOTOR NAMEPLATE DATA MANUFACTURER IEC MANUFACTURER BALDC>R MC)DEL HBC2000051648 HP R.P.M. 1 i 725 SERiAL 969455-50-3 PHASE FRAME 1 56/56H FAN TYPE CEW7RIFUGAL S.F. TYPE 1.15 NG RATING 1990 CFM VOLT3 AMPS 115/2'3p 13.4/6.7 THERMALLY PROTECTEO YES STARTER DATA DRNE DATA MANUFACTURER NONE MOTOR DRNE 1 VP 3_25"OD MODEL MOTOR BORE 5/8" SiZElTHERMAL NO. FAN DRNE i AK 54 RANGE FAN BQRE 314" SET AT�AMPS) .�1TS 8 SLZE 1 �A28 REQ.THERMAL ROTAT10itl CORRECT RATING(AMPS} DRNE CHANGE AlRFlAW DATA TEST DATA INITIAL. F�NqL SUPPLY CFM 2079 FAN R.P.M. 919 OSA CFM 0 VOLTAGE 121 RETURN CFM - 2079 q�pERq� 5$ ATMOS FtLTER COIL -Q.41" rJ 0.16" NOTES: PAGE:3 � H-VQG AIR APPARATUS TEST REPURT PROJECT:BLUE MOOSE PIZZA ARRABELLE UNIT: D1-13 AIR HANDL.ER UNlT DATA MOTOR NAMEPLATE DATA I MANUFACTURER IEC MANUFACTURER BAt.D�R MODEL HBC3400063261 HP R.P.M. 2 1725 SERIAL 199531-10-2 PHASE FRAME 3 56H �AN TYPE CENTRIFUGAL S.F. iYPE 1.15 NG RATING 3100 CFM VOLTS AMPS 208-23U/46fl 6.2-f�.0/3.0 THERlIAALLY PROTECTED YES STARTER DATA DRIVE DATA � MANU�ACTURER NONE MOTOR ORNE 1 VP 4.A"OD � MODEL MOTOR BORE 518" � SIZE/THERNIAL NO. FAN DRIVE 1 FP 5.U"OD RaNGE FAN BORE 1" SET AT tAMPSj .BELTS 8 S2E 1 �A32 REQ.THERMAI. ROTATION CORRECT RATfNG{AMPSj DRIVE CH/�NGE AiRFLt7W DATA TEST DATA INITIAL FlIVqL SUPPLY CFM 3157 FAN R.P.M. 1380 OSA CFM Q VOLTAGE 483-485-482 RETURN CFM 3157 AMpERpGE 2.� _2_� _�.g ATMOS FILTER COIL -0.33" fJ 0.07" NOTES: PAGE:4 . H-VAG AIR TERMINAL TEST REPORT PR4JECT: B�uE M4osE P¢zA-�R�� SYSTEM: FCU pi-��,as,os SYSTEM TERMINAL DESIGN INiT1AL FlNAL NOTES NO TYPE SIZE AK VEL CFM VEL CFM VEL CFM D1-01 1 CD 24x24 4pp 4g7 2 CD 24XZ4 4pp ,�p 3 CD 24X24 200 p� �� 1076 TOTAL D7-03 1 SL 48x6 254 257 2 SL 4sxs 250 --- �� 3 SL 48x6 250 Zg0 4 �- �� 2� 253 5 SL 48x6 250 260 6 SL 48x6 250 261 � s� asxs zsa 2s4 8 SL 48x6 250 251 � 2�47 TOTAL D1-05 1 CD 24�Q4 7p 82 2 GD 24X24 40Q q.'p 3 CO 24x24 400 414 4 CD 24x24 40Q 423 5 CD 24x24 gp 94 6 CD 24X24 23p �g 7 CD 24x24 4pp q,1? �'� 2479 TOTAL N4TES PAGE:�¢,�' �H-VAC AiR TERMINAL TEST REPI�RT PROJECT: eu�MoosE P�a-aRRd��� F SYSTEM: FCU D1 13 SYSTEM TERMINAL DESIGN INiT1AL FtNAL NOTE�3� ND TYPE SIZE AK VEL CFM VEL CFM VEl CFM D1-13 ! SL 48x8 25Q 28p ' � 2 SL 48�c6 250 �7 3 SL 48x6 250 259 4 SL 48x6 250 �,5p 5 SL 48x6 175 180 '� 6 SL 48x6 175 173 — 7 SL 48x6 175 173 � 8 SL 48x6 175 178 9 SL 48x6 175 180 I i 10 SL 48x6 175 185 � 11 SL 48x6 175 172 ; 12 S� 48x6 175 164 ,' 13 SL 48x6 175 173 i � 14 SL 48�t6 9 75 184 l 15 Sl 48x6 175 189 � 16 SL 48x6 175 �gg 3140 3157 TQTAL ' � �-�� OPEN 10x10 .69 797 5�0 811 559 ' � ( . II�_. . _� NOTES PAGE:�6 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Permit #: P07-0169 Job Address: 675 LIONSHEAD PL VAIL Status . . . : ISSUED Location.....: ARRABELLE HOTEL Applied . . : 10/02/2007 Parcel No...: 210106325001 Issued . . . 10/04/2007 Legal Description: Expires . .: 04/O1/2008 Project No : OWNER ARRABELLE AT VAIL SQUARE LLC10/02/2007 PO BOX 7 VAIL CO 81658 APPLICANT COMMERCIAL DESIGN ENGINEERINIO/02/2007 Phone: 970-245-0595 PO BOX 2440 COLORADO SPRINGS CO 80901 License: 228-P CONTRACTOR COMMERCIAL DESIGN ENGINEERINIO/02/2007 Phone: 970-245-0595 PO BOX 2440 COLORADO SPRINGS CO 80901 License: 228-P Desciption: BLUE MOOSE AT ARRABELLE TENANT FINISH Valuation: $9,500.00 Fireplace lnformation:Restricted:?? #of Gas Appliances: ?? #of Gas Logs: ?? #of Wood Pallet: ?? *�***t*****+s****sr+*t***►*strvrt**t+*�*t***►++****�+**t*+r**+******* FEE S UMMARY **********�+****+*+******************+�******ar*******t***�* Plumbing---> $150.0 0 Restuarant Plan Review--> $o.o o Total Calculated Fees---> $191.5 0 Plan Check---> $3 7.5 0 TOTAL FEES--------------> $191.5 0 Additional Fees-----------> $o.o 0 Investigation-> $o.o o Total Permit Fee----------> $191.5 0 Will Call-----> $4.oo Payments-------------------> $191.50 BALANCE DUE---------> $o.o 0 *r****a*s+****+*******************+*******�*****s�s********►**+�***+*�****�aa***�**���*�a***�:+***���**�:���*�►+��*►�**+«a*�*s*****+►**��+�r**+*r* Item: 05100 BUILDING DEPARTMENT 10/02/2007 cgunion Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANC'E. +�,:*...*.*.�**+***.*�*******�..*■*►��.*�++.*.�:++•+:�++.*.�.*�*+»*■��.*.��.+«*.*��.■***********�***********x**�*******.***.*.*■*.*****�..*.***..� DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordin nces of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV BY ELEPH A 79-2149 R AT'OUR OFFICE FROM 8:00 AM-4 PM. SIGNAT RE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER ****************************************************************************+***�*********** TOWN OF VAIL, COLORADO Statement ********�*******++*************************************************************************� Statement Number: R070002078 Amount: $191.50 10/04/200708:17 :�M Payment Method: Check Init: DDG Notation: Commercial Design Engineering 095470 ----------------------------------------------------------------------------- Permit No: P07-0169 Type: PLUMBING PERMIT Parcel No: 2101-063-2500-1 Site Address: 675 LIONSHEAD PL VAIL Location: ARRABELLE HOTEL Total Fees: $191.50 This Payment: $191.50 Total ALL Pmts: $191.50 Balance: $0.00 ***********�*****************************************************+*+************�k*********** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 37.50 PP 00100003111100 PLUMBING PERMIT FEES 150.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ---------------------------------------------------------------- ------------- 10/O1/2007 11:35 FA1 9702451015 �005/006 APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNS����6� Project#: Building Permit#: � �" � Plumbing Permit#: �'�'��`�' ' • 970-479-2149 (Inspections) 75 S. Frontage Rd. Vail,Colorado 81657 TOWN OF VAIL PLUMBING PERMIT APPLICATION q • CONTRACTOR INFORMATION Plumbing Contractor: Town of Vail R No.: Contact Person and Phone#'s: � ' � ' 22� � �c�r �vbGu�.s �i9 �5/92-788� E-Mail Address: '� ���Q Fax#: Contractor Signature: COMPLETE VALUATION FOR PLUMBING PERMIT(Labor&Materials) PLUMBING: � 950� Contac�t Ea /e Coun Assessors O�ce at 970 328 8640 or visit yvww ea /e-coun .com for Parc�e/# Parce) # 2 �O�p� S O Job Name:� Job Address: - I hc luc�1on�� (o�5 L.ic�Sh� P,(ac� ��I3 Legal Description Lot: Block: Filing: Subdivision: Owners Name: `� Address�?5� �/ '� � Phone'99a 3Z Engineer: Address: Phone: Detailed description of work: �l nitSh Work Class: New ( ) Addition( ) Alteration(X) Repair( ) Other( ) Type of Bldg.: Single-family( ) Duplex( ) Multi-family( ) Commerdal(�y Restaurant( ) Other( ) No.of Existing Dwelling Units in this building: No.of Accommodation Units in this building: �**********�****�,��x***fi**************,�FOR OFFICE USE ONLY**�*********,�*��*******�****�*x****** ......- - _ ,.:..... ..,.. ..:: .:.::.: O�Iie;��F�e�s.:=::_:�;.: �:::;:::::;::_;.::�::s:::::;:.Da�e�Re±�eivei�::.:;:::::::;�:::=::::'::.'::;.:.:- .. . �C'c�!_. ......;;B-:"::>=�::::.::::.:::.``;';°,;;:;. ":..`:::; I� � � � � � D � ��;� o � 2007 F:�cdev\FORMS\PERMITS\Building\plumbing_permit_11-23-2005.dot Page 1 of 1 il/23/2005 TOWN OF VAIL «......r 04-23-2008 Inspection Request Reporting / Page 15 4:10 pm Vail, CO - Ci�Of ���'U��'f' Requested Inspect Date: Thursday,April 24, 2008 Inspection Area: CG Site Address: 675 LIONSHEAD PL VAIL ARRABELLE HOTEL A/P/D Information Activity: 607-0260 Type: A-COMM Sub Type: ACOM Status: ISSUED Const Type: Occu�pancy: see plan Use: I-B Insp Area: CG Owner: ARRABELLE AT VAIL SQUARE LLC Contractor: TCD, INC. Phone: (970)453-3959 Description: TENANT FINISH WORK FOR THE BLUE MOOSE AT ARRABELLE Requested Inspection(s) � �/l �� _O � �,�F- � Item: 540 BLDG-Final C/O Requested Tf'me: 04:0 PM Requestor: TCD, INC. --JIM Phone: (970)453-3959 Comments: FINAL MECH/FINAL CO UNIT P111;REQUESTS 1 PM INSPECTION-HAS TO ARRANGE FOR R EST. OP EN�970-445-7245 Assigned To: JMONDRAG�N Entered By: SBELLM K Action: Time Exp: �L/� 1� / i!'�Z%�� � �-� �.� .U°�--� ,�v� �Z- z -� -a � / � �'�� � Inspection Historv Item: 501 PW-Temp.access/draina e Item: 10 BLDG-Footings/Steel+ U�R grd Item: 20 BLDG-Foundation/Steel Item: 30 BLDG-Framing ""Approved"" 10/19/07 Inspector: dplace Action: PA PARTIAL APPROVAL Comment: blue moose-ok to drywall walls. placed a hold on short wall w-3 for elec. inspection and bathroom w-5 for sound insulation. 11/15/07 Inspector: GCD Action: COND APPROVED/CONDITIONS Comment: 12/14/07 Inspector: GCD Action: AP APPROVED Comment: Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail **Approved"* 10/31/07 Inspector: dplace Action: APCR APPROVED/CORRECTION REQD Comment: nail cdx backing so FRP can be applied. 11/21/07 Inspector: GCD Action: AP APPROVED Comment: Item: 70 BLDG-Misc. Item: 90 BLDG-Final "*App roved"" 12/20/07 Inspector: GCD Action: PA PARTIAL APPROVAL Comment: OK FOR TCO 1.RAMP THREASHOLD AT MAIN ENTRY 2.PANIC HARDWARE REQD AT SECONDARY EXIT 3.PLUMBING CORRECTIONS APPR Item: 532 PW-TEMP. C/O Item: 533 PLAN-TEMP. C/O Item: 530 BLDG-Temp. C/O `"Approved"` 12/20/07 Inspector: GCD Action: AP APPROVED Comment: Item: 539 PW-FINAL C/O Item: 537 PLAN-FINAL C/O REPT131 Run Id: 7906 � _ . 04-24-2008 Inspection Request Reporting Page 1 1:14 pm Vail, CO - Citv Of Requested Inspect Date: Thursday,April 24, 2008 Assigned To: CGUNION Inspection Type: MECH Inspection Area: CG Site Address: 675 LIONSHEAD PL VAIL ARRABELLE HOTEL A/P/D Information Activity: M07-0256 Type: B-MECH Sub Type: NCOM Status: ISSUED Const Type: Occu�pancy: Use: Insp Area: CG Owner: ARRABELLE AT VAIL SQUARE LLC Contractor: COMMERCIAL DESIGN ENGINEERING LTD Phone: 970-245-0595 Description: BLUE MOOSE AT ARRABELLE TENANT FINISH Requested Inspection(s) /� /� '� L�-/�` � C./ ( � o`_" Item: 390 MECH-Final Requested Time: 11:30 AM Requestor: COMMERCIAL DESIGN ENGINEERING LTD Phone: 970-245-0595 Assigned To: CGUNION Entered By: DGOLDEN K Action: Time Exp: Comment: CTIONS FOR WR . L ACCESS DOOR COVERS PFR INSTRUCTIONS. Comment: canceled by contractor Comment: 1.HOOD ABOVE CEILING REQD TO BE COVERED WITH DUCT WRAP. 2.LOCATE AND LABEL CLEANOUT AND LOW POINT ON CEILING. 3.PRELIMINARY BALANCE REPORT RECEIVED. CAPTURE TEST APPR. • � Inspection Historv Item: 200 MECH-Rough ""Approved"" 11/07/OT Inspector: GCD Action: CR CORRECTION REQUIRED Comment: 1.ADD 6"SUPPLY IN OFFICE AND RETURN OR DOOR UNDERCUT. 2.SUPPLY NEAR DISHWASHER REQD TO BE SEALED AND INSULATED. GREASE DUCT CONNECTION TO HOOD AND AND MUA REQD OSA AND MUA SUPPLY AND RETURN FOR FCU APPR. 11/20/07 Insp ector: GCD Action: PA PARTIAL APPROVAL Comment: LIGHT TEST FOR GREAS DUCT CONNECTION TO HOOD. Item: 310 MECH-Heating Item: 315 PLMB-Gas Piping ""Approved"" 11/02/07 lnspector: GCD Action: AP APPROVED Comment: 27psi TEST Item: 320 MECH-Exhaust Hoods Item: 330 MECH-Supply Air "Approved"* 10/16/07 Inspector: dpsafe Action: PA PARTIAL APPROVAL Comment: 4 feeds from four fan coils. Item: 340 MECH-Misc. "`Approved*" 10/18/07 Inspector: SB Action: AP APPROVED Comment: GREASE DUCK COMPLETE--LIGHT TEST APPROVED 11/20/07 Inspector: GCD Action: AP APPROVED Comment: SEE ROUGH Item: 390 MECH-Final ""A�pproved"' 11/30/07 Inspector: GCD Action: CR CORRECTION REQUIRED REPT131 Run Id: 7910