Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B06-0015 - Structural Engineering Calcs
1 lഀ Monroe & Newellഀ Engineers, Inc.ഀ STRUCTURAL ENGINEERING CALCULATIONSഀ For:ഀ Vail's Front Doorഀ Building "B"ഀ Spa and Guestroom Suite Additionഀ Vail, Coloradoഀ M&N # 5500.02ഀ 1%111#91601111 .4ഀ KAWഀ O~ഀ •r'~~'~~a'~ONAIEN+G~Q•~~ Oഀ ftctoo,•••~ i (0ഀ These drawings and calculations are the property of Monroe & Newell Engineers, Inc. Any use orഀ reproductions of these calculations without the expressed written permission of Monroe & Newellഀ Engineers, Inc. is strictly prohibited.ഀ Vail, Coloradoഀ Denver, Coloradoഀ Dillon, Coloradoഀ **P.E. stamp on sheet applies to the following calculation pages and indicates that have been reviewed.ഀ This includes all sheets attached to this cover.ഀ January 10, 2006ഀ 2005 Platinum Sponsorഀ I he Colorado Chaptcr ofഀ The 1A111eriaul Institute ol',\rchilcctsഀ www.monroe-newell.comഀ 1701 Wynkoop Street * Suite 200 • Denver, Colorado 80202ഀ (303) 623-4927 * FAX (303) 623-6602 • email: denver@monroe-newell cnmഀ MONROE & NEWELL ENGINEERS, INC.ഀ DESIGN CRITERIA-COMMERCIALഀ Project Name: Vail's Front Door Building B Date: January 2006ഀ Spa and Guestroom Suite Additionഀ Location: Vail, Colorado Project#: 5500.02ഀ Building Department: Town of Vail, Colorado Phone:ഀ Contact: Building Code/Year: 2003 IBCഀ Live Loads:ഀ See Attached General Notesഀ Wind:ഀ Speed 100 MPH Exposure Bഀ Seismic Zone: See Attached General Notes Frost depth: 48 inchesഀ Foundation Criteria:ഀ Soils Engineer: Koechlein Consulting Engineers, Inc. Report 03-015ഀ Report Date: August 19, 2003ഀ Foundation Design Criteria:ഀ Allowable bearing (DL+LL) 5000 psf on soilsഀ 20000 psf on bedrockഀ Wall span required 10 FTഀ Soil modulus (vertical) 200 PCIഀ Lateral:ഀ Active (unrestrained) 40 PCF (on-site soils) 35 PCF (imported gravel)ഀ At rest (restrained) 55 PCF (on-site soils) 45 PCF (imported gravel)ഀ Passive 300 PCF (on-site soils) 350 PCF (imported gravel)ഀ Sliding friction coefficient 0.4ഀ PROJECT: VAIL'S FRONT DOORഀ M&N 5500.02ഀ DATE: JANUARY 04, 2006ഀ GENERAL NOTESഀ NOTE:ഀ THESE GENERAL NOTES INCLUDE THE REQUIREMENTS FOR ALL BUILDINGSഀ OF THE VAIL'S FRONT DOOR PROJECT. THEREFORE NOT ALL SECTIONS OFഀ THE NOTES MAY APPLY TO EACH BUILDING.ഀ 1. LIVE LOADS USED IN DESIGN:ഀ A.ഀ PARKING GARAGE AND TUNNELഀ 1. ROOF (SNOW)ഀ 100 PSFഀ 2. ROOF (TRUCK TRAFFIC)ഀ AASHTO HS-20ഀ 3. UPPER LEVEL PARKINGഀ 40 PSFഀ 4. MID-LEVEL PARKINGഀ 40 PSFഀ 5. MID-LEVEL TUNNELഀ AASHTO HS-20ഀ 6. POOL (5'-0" DEPTH MAX)ഀ 320 PSFഀ B.ഀ SPAഀ 1. ROOF (SNOW)ഀ 100 PSFഀ 2. RESIDENCE LEVELഀ 40 PSFഀ 3. SPA LEVELSഀ 100 PSFഀ C.ഀ SKI CLUBഀ 1. ROOF (SNOW)ഀ 80 PSFഀ 2. GROUND LEVEL FLOORഀ 100 PSFഀ 3. MID LEVEL FLOORഀ 125 PSFഀ D.ഀ SKIER SERVICESഀ 1. ROOF(SNOW) 4/12 & GREATER'SLOPEഀ 80 PSFഀ 2. ROOF SNOW LESS THAN 4/12 SLOPEഀ 100 PSFഀ 3. GROUND LEVEL FLOORഀ 100 PSFഀ 4. LOWER LEVELഀ 125 PSFഀ E.ഀ RESIDENCE'S PARKING GARAGEഀ 1. ROOF (SNOW)ഀ 100 PSFഀ 2. MECHANICAL AND STORAGE LEVELഀ 125 PSFഀ F.ഀ RESIDENCESഀ 1. ROOF (SNOW)ഀ 80 PSFഀ 2. FLOORSഀ 40 PSFഀ 3. EXTERIOR DECKS (SNOW)ഀ 100 PSFഀ G.ഀ IMPORTANCE FACTORSഀ CATEGORYഀ IIഀ SEISMIC FACTOR IEഀ 1.0ഀ SNOW FACTOR ISഀ toഀ WIND FACTOR I,,vഀ 1.0ഀ 1ഀ H. WINDഀ 3 SECOND GUST 100 MPHഀ FASTEST MILE 80 MPHഀ EXPOSURE Bഀ SEISMICഀ a. PARKING GARAGE & TUNNEL/SITE CLASSഀ SITE CLASS Dഀ CATEGORY Bഀ SS 0.284ഀ S, 0.068ഀ SpS 0.298ഀ Spy 0.045ഀ BASIC SEISMIC FORCE RESISTING SYSTEM IS CONCRETE SHEAR WALLSഀ SEISMIC RESPONSE COEFFICIENTS CS 0.066ഀ RESPONSE MODIFICATION FACTOR 4.0ഀ ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCEഀ SEISMICഀ b. SPAഀ SITE CLASS Dഀ CATEGORY Bഀ SS 0.284ഀ S, 0.068ഀ SOS 0.298ഀ SDI 0.045ഀ BASIC SEISMIC FORCE RESISTING SYSTEM IS MASONRY SHEAR WALLSഀ SEISMIC RESPONSE COEFFICIENTS CS 0.066ഀ RESPONSE MODIFICATION FACTOR 2.0ഀ ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCEഀ C. SKI CLUBഀ SITE CLASS Dഀ CATEGORY Bഀ SS 0.284ഀ S, 0.068ഀ SpS 0.298ഀ SDI 0.045ഀ BASIC SEISMIC FORCE RESISTING SYSTEM IS CONCRETE SHEAR WALLSഀ SEISMIC RESPONSE COEFFICIENTS CS 0.066ഀ RESPONSE MODIFICATION FACTOR 4.5ഀ ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCEഀ d. SKIER SERVICESഀ SITE CLASS Dഀ CATEGORY Bഀ SS 0.284ഀ S, 0.068ഀ SpS 0.298ഀ SDI 0.045ഀ BASIC SEISMIC FORCE RESISTING SYSTEM IS CONCRETE SHEAR WALLSഀ SEISMIC RESPONSE COEFFICIENTS CS 0.066ഀ RESPONSE MODIFICATION FACTOR 4.0ഀ ANALYSIS PROCEDURE USED EQUIVALENT LATERAL FORCEഀ e. RESIDENCE AND GARAGEഀ SITE CLASSഀ CATEGORYഀ SSഀ S,ഀ SDSഀ SD1ഀ BASIC SEISMIC FORCE RESISTING SYSTEM ISഀ SEISMIC RESPONSE COEFFICIENTS CSഀ RESPONSE MODIFICATION FACTORഀ ANALYSIS PROCEDURE USEDഀ Bഀ Bഀ 0.35ഀ 0.08ഀ 0.23ഀ 0.053ഀ LIGHT FRAME SHEAR WALLSഀ 0.058ഀ 4ഀ EQUIVALENT LATERAL FRAMEഀ LIVE LOADS ARE REDUCED PER CODE IF APPLICABLE.ഀ DEFERRED SUBMITTALഀ A. DEFERRED SUBMITTALS PER SECTION 1063.4.1 SHALL BE SUBMITTED TO THE BUILDINGഀ OFFICIAL AND THE DESIGN PROFESSIONALS AND REVIEWED PRIOR TO INSTALLATION.ഀ B. DEFERRED. SUBMITTALS ARE:ഀ PREFABRICATED FLOOR TRUSSES/JOISTSഀ C. ALL DEFERRED SUBMITTALS SHALL BEAR THE STAMP AND SIGNATURE OF THE LICENSEDഀ PROFESSIONAL ENGINEER RESPONSIBLE FOR THE PREPARATION OF THESE DOCUMENTS.ഀ TESTING INSPECTIONS AND OBSERVATIONS:ഀ A. THE STRUCTURAL ENGINEER DOES NOT PROVIDE INSPECTIONS OF CONSTRUCTION.ഀ STRUCTURAL ENGINEER MAY MAKE PERIODIC OBSERVATIONS OF THEഀ CONSTRUCTION; SUCH OBSERVATIONS SHALL NOT REPLACE REQUIREDഀ INSPECTIONS BY THE GOVERNING AUTHORITIES OR SERVE AS "SPECIALഀ INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONALഀ BUILDING CODE.ഀ B. THE FOLLOWING WORK SHALL BE INSPECTED BY THE SPECIAL INSPECTOR UNLESSഀ SPECIFICALLY WAIVED BY THE BUILDING OFFICIAL.ഀ SOIL PREPARATIONഀ a. EARTHWORK EXCAVATION, PLACEMENT AND COMPACTION OF FILLഀ AND IN-PLACE DRY DENSITY OF THE COMPACTED FILL FOR CONFORMANCEഀ WITH THE APPROVED REPORT.ഀ 2. CONCRETE CONSTRUCTIONഀ a. PERIODIC INSPECTION OF REINFORCING STEEL, INCLUDING POST-TENSIONINGഀ TENDONS AND PLACEMENT.ഀ b. CONTINUOUS INSPECTION OF PLACEMENT OF SHEAR REINFORCEMENT.ഀ C. PERIODIC VERIFICATION OF WELDABILITY OF REINFORCING STEEL OTHERഀ THAN ASTM A706.ഀ d. CONTINUOUS INSPECTION OF REINFORCING STEEL-RESISTING FLEXURAL ANDഀ AXIAL FORCES IN INTERMEDIATE AND SPECIAL MOMENT FRAMES, AND BOUNDARYഀ ELEMENTS OF SPECIAL REINFORCED CONCRETE SHEAR WALLS AND SHEARഀ REINFORCEMENT.ഀ e. CONTINUOUS INSPECTION OF BOLTS TO BE INSTALLED IN CONCRETE PRIORഀ TO AND DURING PLACEMENT OF CONCRETE.ഀ f. PERIODIC VERIFICATION OF USE OF REQUIRED DESIGN MIX.ഀ g. CONTINUOUS INSPECTION AT THE TIME FRESH CONCRETE IS SAMPLED TOഀ FABRICATE SPECIMANS FOR STRENGTH TESTS, PERFORM SLUMP AND AIRഀ CONTENT TESTS AND DETERMINE THE TEMPERATURE OF THE CONCRETE.ഀ h. CONTINUOUS INSPECTION OF CONCRETE AND SHOTCRETE PLACEMENT FORഀ PROPER APPLICATION TECHNIQUES.ഀ i. PERIODIC INSPECTION FOR MAINTENANCE OF SPECIFIED CURING TEMPERATUREഀ AND TECHNIQUES.ഀ j. CONTINUOUS INSPECTION OF APPLICATION OF POST-TENSIONING FORCES.ഀ k. PERIODIC VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO STRESSINGഀ OF TENDONS IN POST TENSIONED CONCRETE AND PRIOR TO REMOVAL OFഀ SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS.ഀ STEEL CONSTRUCTIONഀ a. ALL WELDING SHALL RECEIVE CONTINUOUS SPECIAL INSPECTIONഀ EXCEPT THE FOLLOWING:ഀ 1. WELDING DONE IN AN APPROVED FABRICATOR'S SHOP INഀ ACCORDANCE WITH SECTION 1704.3.ഀ b. THE SPECIAL INSPECTOR NEED NOT BE CONTINUOUSLY PRESENTഀ DURING WELDING OF THE FOLLOWING ITEMS, PROVIDED THE MATERIALS,ഀ WELDING PROCEDURES AND QUALIFICATIONS OF WELDERS AREഀ VERIFIED PRIOR TO THE START OF WORK; PERIODIC INSPECTIONS AREഀ MADE OF WORK IN PROGRESS; AND A VISUAL INSPECTION OF ALL WELDSഀ IS MADE PRIOR TO COMPLETION OR PRIOR TO SHIPMENT OF SHOPഀ WELDING.ഀ 1. SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE.ഀ 2. FLOOR AND ROOF DECK WELDING.ഀ 3. WELDED STUDS WHEN USED FOR STRUCTURAL DIAPHRAGM.ഀ 4. WELDED SHEET STEEL FOR COLD FORMED STEEL FRAMINGഀ MEMBERS SUCH AS STUDS AND JOISTS.ഀ 5. WELDING OF STAIRS AND RAILING SYSTEMS.ഀ C. VERIFY WELD FILLER MATERIALS CONFORM TO AWS SPECIFICATIONS ANDഀ MANUFACTURER'S CERTIFICATE OF COMPLIANCE IS REQUIRED.ഀ d. PERIODIC INSPECTION OF THE STEEL FRAME TO VERIFY COMPLIANCE WITHഀ THE DETAILS SHOWN ON THE APPROVED CONSTRUCTION DOCUMENTS SUCHഀ AS BRACING, STIFFENING, MEMBER LOCATIONS AND PROPER APPLICATION OFഀ JOINT DETAILS AT EACH CONNECTION.ഀ e. VERIFY STRUCTURAL STEEL MATERIAL CONFORMS TO ASTM STANDARDSഀ SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS ANDഀ MANUFACTURER'S CERTIFIED MILL TEST REPORTS.ഀ f. PERIODIC VERIFICATION OF HIGH STRENGTH BOLTS, NUTS AND WASHERS FORഀ CONFORMANCE TO ASTM STANDARDS SPECIFIED IN THE APPROVEDഀ CONSTRUCTION DOCUMENTS AND MANUFACTURER'S CERTIFICATE OFഀ COMPLIANCE.ഀ g. CONTINUOUS INSPECTION OF SLIP-CRITICAL CONNECTION WITH HIGH STRENGTHഀ BOLTS. PERIODIC INSPECTION OF BEARING TYPE CONNECTORS WITH HIGHഀ STRENGTH BOLTS.ഀ WHILE THE WORK IS IN PROGRESS, THE SPECIAL INSPECTOR SHALLഀ DETERMINE THAT THE REQUIREMENTS FOR BOLTS, NUTS, WASHERS ANDഀ PAINT, BOLTED PARTS AND INSTALLATION AND TIGHTENING IN SUCHഀ STANDARDS ARE MET. FOR BOLTS REQUIRING PRETENSIONING, THEഀ SPECIAL INSPECTOR SHALL OBSERVE THE PREINSTALLATION TESTING ANDഀ CALIBRATION PROCEDURES WHEN SUCH PROCEDURES ARE REQUIRED BYഀ 4ഀ THE INSTALLATION METHOD OR BY PROJECT PLANS OR SPECIFICATIONS;ഀ DETERMINE THAT ALL PLIES OF CONNECTED MATERIALS HAVE BEENഀ DRAWN TOGETHER AND PROPERLY SNUGGED AND MONITOR THEഀ INSTALLATION OF BOLTS TO VERIFY THAT THE SELECTED PROCEDURE FORഀ INSTALLATION IS PROPERLY USED TO TIGHTEN BOLTS. FOR JOINTSഀ REQUIRED TO BE TIGHTENED ONLY TO THE SNUG-TIGHT CONDITION, THEഀ SPECIAL INSPECTOR NEED ONLY VERIFY THAT THE CONNECTEDഀ MATERIALS HAVE BEEN DRAWN TOGETHER AND PROPERLY SNUGGED.ഀ MONITORING OF BOLT INSTALLATION FOR PRETENSIONING IS PERMITTEDഀ TO BE PERFORMED ON A PERIODIC BASIS WHEN USING THE TURN-OF-NUTഀ METHOD WITH MATCHMARKING TECHNIQUES, THE DIRECT TENSIONഀ INDICATOR METHOD OR THE ALTERNATE DESIGN FASTENER (TWIST-OFFഀ BOLT) METHOD. JOINTS DESIGNATED AS SNUG TIGHT NEED TO BEഀ INSPECTED ONLY ON A PERIODIC BASIS.ഀ 4. MASONRY CONSTRUCTIONഀ a. THE MINIMUM SPECIAL INSPECTION PROGRAM FOR MASONRY SHALL BE ASഀ FOLLOWS:ഀ FROM THE BEGINNING OF MASONRY CONSTRUCTION, THE FOLLOWINGഀ SHALL BE VERIFIED TO ENSURE COMPLIANCE:ഀ a. PROPORTIONS OF SITE-PREPARED MORTAR AND GROUT.ഀ (PERIODICALLY)ഀ b. PLACEMENT OF MASONRY UNITS AND CONSTRUCTION OF MORTARഀ JOINTS. (PERIODICALLY)ഀ c. PLACEMENT OF REINFORCEMENT, CONNECTORS AND ANCHORAGESഀ (PERIODICALLY)ഀ d. GROUT SPACE PRIOR TO GROUTING. (CONTINUOUSLY)ഀ e. PLACEMENT OF GROUT. (CONTINUOUSLY)ഀ 2. THE INSPECTION PROGRAM SHALL VERIFY:ഀ a. SIZE AND LOCATION OF STRUCTURAL ELEMENTS. (PERIODICALLY)ഀ b. TYPE, SIZE AND LOCATIIN OF ANCHORS, INCLUDING OTHERഀ DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS,ഀ FRAMES OR OTHER CONSTRUCTION. (CONTINUOUSLY)ഀ C. SPECIFIED SIZE, GRADE AND TYPE OF REINFORCEMENT.ഀ (PERIODICALLY)ഀ d. WELDING OF REINFORCEMENT. (PERIODICALLY)ഀ e. PROTECTION OF MASONRY DURING COLD WEATHER (TEMPERATUREഀ BELOW 40 DEGREES F) OR HOT WEATHER (TEMPERATURE ABOVE 90ഀ DEGREES F).ഀ (PERIODICALLY)ഀ 3. PREPARATION OF ANY REQURED GROUT SPECIMENS, MORTAR SPECIMENSഀ AND/OR PRISMS SHALL BE OBSERVED. (CONTINUOUSLY)ഀ 4. COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF THEഀ CONSTRUCTION DOCUMENTS AND THE APPROVED SUBMITTALS SHALL BEഀ VERIFIED. (PERIODICALLY)ഀ 4. FOUNDATIONSഀ A. MAXIMUM SOIL DESIGN PRESSUREഀ BED ROCKഀ SOILഀ 20,000 PSFഀ 5,000 PSFഀ B. CONTRACTOR TO FOLLOW ALL RECOMMENDATIONS IN SOILS REPORT NO. 03-015ഀ BY KOECHLEIN CONSULTING ENGINEERS, INC. DATED 19 AUGUST 2003.ഀ C. ALL FOOTING BEARING ELEVATIONS SHOWN ARE ASSUMED. EXACT BEARINGഀ ELEVATIONS SHALL BE VERIFIED IN THE FIELD WITH ACTUAL CONDITIONS BYഀ CONTRACTOR WITH APPROVAL OF SOILS ENGINEER AND ALL BOTTOMS OF FOOTINGSഀ SHALL BE A MINIMUM OF 48" BELOW EXTERIOR GRADE.ഀ D. ALL FOOTINGS ARE TO BE PLACED ON FIRM, UNDISTURBED, NATURAL SOIL ORഀ PROPERLY COMPACTED BACKFILL, APPROVED BY THE SOILS ENGINEER. BACKFILLഀ SHALL BE COMPACTED TO 95% (MINIMUM) MODIFIED PROCTOR DENSITY PER ASTMഀ D1557 UNLESS OTHERWISE RECOMMENDED IN THE SOILS REPORT. IF SOFT SPOTS AREഀ ENCOUNTERED REMOVE SOIL AND RECOMPACT WITH APPROVED FILL (RE: SOILഀ REPORT FOR DESCRIPTION OF BEARING SOIL).ഀ E. CONTRACTOR SHALL BACKFILL EQUALLY ON EACH SIDE OF FOUNDATION WALLS IN 12ഀ INCH MAXIMUM VERTICAL LIFTS OR AS RECOMMENDED IN THE SOILS REPORT. REFERഀ TO SOILS REPORT FOR BACKFILL MATERIAL.ഀ F. NO BACKFILLING SHALL BE PLACED AGAINST LOWER LEVEL WALLS UNTIL THE LOWERഀ LEVEL FLOOR AND MAIN LEVEL FLOOR ARE IN PLACE AND PROPERLY ANCHORED.ഀ CONCRETE SLABS SHALL BE PROPERLY CURED.ഀ G. CENTER ALL FOOTINGS, ON COLUMNS OR GRID LINES UNLESS NOTED OTHERWISEഀ ON PLANS.ഀ H. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TESTS ON COMPACTEDഀ FILL UNDER FOOTINGS AND INTERIOR SLABS-ON-GRADE.ഀ NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPLETED SO THAT CONDITIONS MAYഀ BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE.ഀ 5. SLAB ON GRADEഀ A. THE PREPARATION OF THE SUBGRADE FOR THE SLAB ON GRADE SHALL BE IN STRICTഀ ACCORDANCE WITH THE PROJECT SOILS REPORT REFERENCED ABOVE. THEഀ CONTRACTOR SHALL DIRECT QUESTIONS REGARDING THE SUBGRADE PREPARATIONഀ REQUIREMENTS TO THE GEOTECHNICAL ENGINEER.ഀ B. MOVEMENT OF THE SLAB ON GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTEDഀ TO BOTH THE SLAB AND OTHER PORTIONS OF THE SUPERSTRUCTURE. ISOLATIONഀ DETAILS FOR PARTITION WALLS, BASEBOARDS, PIPING AND OTHER ITEMS MAY BEഀ REQUIRED. REFER TO THE APPROPRIATE DRAWINGS OR CONSULT WITH THEഀ RESPONSIBLE MEMBER OF THE DESIGN TEAM PRIOR TO CONNECTING ITEMS TO BOTHഀ THE SLAB ON GRADE AND OTHER PORTIONS OF THE SUPERSTRUCTURE.ഀ & CONCRETEഀ A. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE 1/11 PORTLAND CEMENT,ഀ STONE AGGREGATE AND SHALL SATISFY THE FOLLOWING REQUIREMENTS:ഀ CONCRETE ITEM F'C MIX TYPE MAX W/C RATIO % AIR REQ.ഀ 6ഀ FOOTINGS &FOUNDATION WALLSഀ INTERIOR SLABS ON GRADEഀ INTERIOR STRUCTURAL SLABS,ഀ BEAMS, WALLBEAMS AND COLUMഀ SLABS ON METAL DECKഀ EXTERIOR CONCRETEഀ 4000 psi STDഀ 4000 psi STD 0.50ഀ NS 5000 psi STD 0.50ഀ 3500 psi STD 0.50ഀ 4000 psi STD 0.45 6%-8%ഀ MAXIMUM SLUMP SHALL NOT EXCEED 4"ഀ B. IF CONCRETE SUPPLIER PROPOSES USE OF FLYASH HE SHALL PROVIDE OWNER WITHഀ LETTER INDICATING COST REDUCTION AT TIME OF BID. THE MODULUS OF ELASTICITYഀ OF ALL CONCRETE SHALL EXCEED WC1.5 33 ~ F'C (OR 57,000 ~ F'C NORMAL WEIGHTഀ CONCRETE).ഀ C. CONTRACTOR SHALL SAWCUT OR TROWELCUT JOINTS IN SLABS ON GRADE. JOINTSഀ SHALL BE SPACED 15'-0 FEET MAXIMUM AND SAWCUT OR TROWELCUT 1/4 OF SLAB DEPTH X 3/16"ഀ WIDE WITHIN 12 HOURS AFTER POURING. CARRY ALL SLAB REINFORCEMENT THROUGHഀ JOINT.ഀ D. SLABS, FOOTINGS, BEAMS AND WALLS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANYഀ STOP IN CONCRETE WORK MUST BE MADE AT THIRD POINT OF SPAN WITH VERTICAL BULKHEADSഀ AND HORIZONTAL SHEAR KEYS UNLESS OTHERWISE SHOWN. ALL CONSTRUCTION JOINTS SHALLഀ BE AS DETAILED OR AS REVIEWED BY THE ENGINEER.ഀ E. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCEഀ WITH ACI BUILDING CODE 318 LATEST EDITION, UNLESS NOTED OTHERWISE. USEഀ STANDARD HOOKS FOR DOWELS UNLESS NOTED OTHERWISE. ALL EXPOSED EDGES OFഀ CONCRETE WORK SHALL HAVE 3/4 INCH CHAMFER.ഀ REINFORCEMENTഀ A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTMഀ A615, GRADE 60 EXCEPT TIES.ഀ B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 GRADE 65 AND SHALL BEഀ LAPPED ONE FULL MESH AT SIDE AND END SPLICES AND WIRED TOGETHER.ഀ C. REINFORCEMENT PROTECTION UNLESS NOTED OTHERWISE-ഀ 1 . CONCRETE POURED AGAINST EARTH 3"ഀ 2. CONCRETE POURED IN FORMS (EXPOSED TO WEATHER OR EARTH) 2"ഀ 3. COLUMNS AND BEAMS (TIE BARS) 1-1/2"ഀ 4. SLABS AND WALLS (NOT EXPOSED TO WEATHER) 3/4"ഀ D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITHഀ SECTIONS 7.5, 7.6 AND 7.7 OF ACI 318, LATEST EDITION.ഀ E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED ORഀ AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES, WHERE PERMITTED, SHALLഀ BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER AND SHALL BE Aഀ MINIMUM OF 80 BAR DIAMETERS FOR #7 AND #8 REINFORCEMENT UNLESS NOTEDഀ OTHERWISE. MAKE ALL BARS CONTINUOUS AROUND CORNERS.ഀ F. PLACE TWO #5 (PER 8" THICKNESS) WITH 2'-0" PROJECTION AROUND ALL OPENINGS INഀ CONCRETE WALLS, SLABS, AND BEAMS. ALSO PROVIDE TWO #5 X 4'-0" DIAGONALLY ATഀ EACH CORNER.ഀ 7ഀ G. CONTINUOUS TOP AND BOTTOM BARS IN WALLS AND BEAMS SHALL BE SPLICED ASഀ FOLLOWS: TOP BARS AT MIDSPAN, BOTTOM BARS OVER SUPPORTS.ഀ POST-TENSIONINGഀ A. TENDONS FOR POST-TENSIONING SHALL BE UNCOATED SEVEN WIRE STRESS RELIEVEDഀ STEEL STRAND HAVING AN ULTIMATE STRENGTH OF 270 KSI AND SHALL MEET ASTMഀ STANDARDS A416. OIL TEMPERED WIRES SHALL NOT BE USED. STRAND SHALL BE COATEDഀ WITH A RUST PREVENTATIVE GREASE AND ENCLOSED IN AN EXTRUDED PLASTIC SLIPPAGEഀ SHEATHING.ഀ B. COUPLINGS SHALL BE USED ONLY AT LOCATIONS INDICATED AND/OR AS REVIEWED BYഀ THE STRUCTURAL ENGINEER.ഀ C. POST-TENSIONING OPERATION SHALL NOT COMMENCE UNTIL CONCRETE CYLINDERS,ഀ CURED UNDER JOB-SITE CONDITIONS, HAVE BEEN TESTED AND INDICATED 3000 PSIഀ COMPRESSIVE STRENGTH.ഀ D. CALCIUM CHLORIDE AND FLYASH SHALL NOT BE USED.ഀ E. ALL REINFORCING AND POST-TENSIONING TENDONS SHALL BE FIRMLY SECURED TOഀ PREVENT DISPLACEMENT DURING POURING OF CONCRETE. STAPLE ALL CHAIRSഀ MINIMUM TWO STAPLES EACH.ഀ POST-TENSIONING TENDON SUPPLIER TO INCREASE FORCES SHOWN AS NECESSARYഀ TO OVERCOME FRICTION FORCES AS PER LATEST POST-TENSIONING DESIGNഀ INSTITUTE RECOMMENDATIONS. ALL FORCES SHOWN ARE FINAL EFFECTIVE.ഀ G. ALL POST-TENSIONING TENDONS SHALL BE NO LESS THAN 4" FROM ANY OPENING.ഀ H. ALL POST-TENSIONING TENDONS TO BE BENT AROUND OPENING SHALL EXTEND Aഀ MINIMUM OF 2'-0" PAST THE OPENING BEFORE STARTING CURVE.ഀ I. HORIZONTAL SLOPE OF POST-TENSIONING TENDONS SHALL BE LIMITED TO 1:6.ഀ J. UNIFORM TENDONS SHALL BE STRESSED PRIOR TO BANDED TENDONS. STRESS SLABഀ TENDONS BEFORE STRESSING BEAM TENDONS.ഀ K. IT SHALL BE CONTRACTOR'S RESPONSIBILITY TO VERIFY BY APPLICABLE METHODS,ഀ LOCATIONS OF TENDONS PRIOR TO INSTALLATION OF ANY SLAB PENETRATIONSഀ GREATER THAN 3/4" DEEP.ഀ L. ALL JACKING OF TENDONS SHALL BE DONE WITH AN AUTOMATIC POWER SEATING JACK.ഀ M. NOTIFY ENGINEER AT LEAST 72 HOURS IN ADVANCE OF CONCRETE POUR SO THATഀ STEEL AND TENDON PLACEMENT MAY BE OBSERVED PRIOR TO CONCRETE POUR.ഀ N. PROVIDE 244 BACKUP BARS AT ALL TENDON ANCHORAGES. BARS SHALL EXTENDഀ MINIMUM 2'-0 EACH SIDE OF ANCHORAGE.ഀ 0. TENSILE STRESS IN PRESTRESSING TENDONS SHALL NOT EXCEED THE FOLLOWING:ഀ 1. DUE TO TENDON JACKING FORCE 0.94 fpy BUT NOT GREATER THAN 0.85 fpu ORഀ MAXIMUM VALUE RECOMMENDED BY MANUFACTURERS OF PRESTRESSINGഀ TENDONS OR ANCHORAGES.ഀ 2. IMMEDIATELY AFTER PRESTRESS TRANSFER 0.82 fpy BUT NOT GREATER THANഀ 8ഀ 0.74 fpu.ഀ 3. POST-TENSIONING TENDONS, AT ANCHORAGES AND COUPLERS IMMEDIATELYഀ AFTER TENDON ANCHORAGE 0.70 fpu.ഀ P. RECORDS OF ALL TENDON JACKING FORCES AND ELONGATION SHALL BE SUBMITTEDഀ TO THE STRUCTURAL ENGINEER. ELONGATION MEASUREMENT SHALL BE OBSERVED BYഀ A PARTY INDEPENDENT OF THE COMPANY RESPONSIBLE FOR TENDON ELONGATION.ഀ MASONRYഀ A. ALL MASONRY CONSTRUCTION REQUIRES SPECIAL INSPECTIONS PER CHAPTER 17 OF THEഀ INTERNATIONAL BUILDING CODE.ഀ B. CONCRETE BLOCK UNITS SHALL CONFORM TO ASTM C90, GRADE N. BRICK SHALLഀ FULFILL ASTM C62, C216 OR C652. MORTAR SHALL BE ASTM C270 TYPE S OR M.ഀ C.' MASONRY SHALL CONSIST OF CONCRETE BLOCK WITH A MINIMUM COMPRESSIVEഀ STRENGTH OF F'n, OF 1900 PSI BASED ON NET AREA.ഀ D. WALLS SHALL BE REINFORCED HORIZONTALLY AT 16" ON CENTER WITH 9 GAGEഀ MINIMUM LADDER-TYPE REINFORCEMENT MEETING ASTM A82 MASONRY WALLഀ REINFORCEMENT. HORIZONTAL REINFORCING SHALL BE CONTINUOUS AROUNDഀ CORNERS.ഀ E. UNLESS NOTED OTHERWISE, MASONRY WALLS SHALL ALSO BE REINFORCED WITHഀ ONE #5 VERTICALLY AT WALL ENDS, CORNERS, EACH SIDE OF DOOR OR WINDOWഀ OPENINGS AND AT NOT OVER 4'-0" ON CENTER TYPICALLY. REINFORCEMENTഀ SHALL BE FULLY GROUTED IN PLACE. GROUT SHALL DEVELOP 3000 PSI IN 28 DAYS ANDഀ MEET ASTM C476.ഀ F. ALL CMU WALLS REQUIRE A MINIMUM OF 245 IN BOND BEAM ABOVE ALL DOORS ANDഀ WINDOWS, AT FLOOR AND ROOF LINES, AND TOP OF PARAPETS UNLESS OTHERWISEഀ NOTED.ഀ G. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION JOINT LOCATIONS.ഀ H. FILL ALL VOIDS AND BLOCK CELLS SOLIDLY WITH ASTM C476 GROUT FOR A DISTANCEഀ OF 24" BENEATH AND A MINIMUM OF 16" EACH SIDE OF ALL BEAM REACTIONS OR OTHERഀ CONCENTRATED LOADS UNLESS NOTED OTHERWISE.ഀ 1. CMU SHALL BE FULLY GROUTED BELOW GRADE.ഀ J. PROVIDE A THICKENED CONCRETE SLAB UNDER ALL MASONRY PARTITION WALLS. SEEഀ ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF WALLS AND FORഀ OPENINGS, ALL OF WHICH REQUIRE LINTELS. SEE LOOSE LINTEL SCHEDULE FORഀ FRAMING OVER NON-BEARING OPENINGS IF NOT SHOWN ON STRUCTURAL DRAWINGS.ഀ SEE MECHANICAL DRAWINGS FOR THOSE OPENINGS WHICH REQUIRE LINTELS.ഀ K. ALL MULTIPLE WYTHE MASONRY WALLS SHALL BE GROUTED SOLID BETWEEN EACHഀ WYTHE WITH ASTM C476 GROUT.ഀ L. WHERE MASONRY LINTELS CROSS EXPANSION CONTROL JOINTS IN MASONRY, INSTALLഀ LINTELS SO THAT THE LINTEL MAY SLIDE ON ONE END.ഀ M. PROVIDE MASONRY TIES WHERE MASONRY ABUTS CONCRETE.ഀ 10. STRUCTURAL STEELഀ A. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 EXCEPT WIDE FLANGE BEAMSഀ WHICH SHALL CONFORM TO ASTM 992, (50 KSI) AND EXCEPT PIPE COLUMNS WHICHഀ SHALL CONFORM TO ASTM A53 AND TUBE COLUMNS TO ASTM A500, GRADE B, LATESTഀ EDITIONS. STEEL SUPPLIER MAY PROVIDE ASTM A572, GRADE 50 AT HIS OPTION.ഀ MISCELLANEOUS EMBEDDED ITEMS SHALL BE A36 STEEL.ഀ B. ALL STRUCTURAL BOLTS SHALL BE A325N INSTALLED TO A MINIMUM SNUG TIGHTഀ CONDITION. ALL ANCHOR BOLTS SHALL CONFORM TO ASTM A307 UNLESS NOTEDഀ OTHERWISE.ഀ C. STRUCTURAL STEEL SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THEഀ LATEST PROVISIONS OF AISC "MANUAL OF STEEL CONSTRUCTION."ഀ D. EXCEPT WHERE DETAILED OTHERISE, FABRICATOR SHALL SELECT STEEL CONNECTIONS PERഀ AISC "MANUAL OF STEEL CONSTRUCTION" (ASD), TABLE 11-A AND/OR AISC "SIMPLE SHEARഀ CONNECTION MANUAL" WITH A325 N BOLTS (OR WELDED EQUIVALENT) TO SUPPORT LOADSഀ INDICATED ON THE STRUCTURAL DRAWINGS. WHEN LOADS ARE NOT SHOWN, SELECTഀ CONNECTION TO SUPPORT 60% THE TOTAL UNIFORM LOAD CAPACITY PER AISC "MANUAL OFഀ STEEL CONSTRUCTION" FOR EACH GIVEN BEAM AND SPAN FOR NON-COMPOSITEഀ MEMBERS. FOR COMPOSITE MEMBERS, CONNECTIONS SHALL SUPPORT 75% OF THEഀ TOTAL CAPACITY FOR EACH BEAM AND SPAN.ഀ SUBMIT DESIGN CALCULATIONS, BEARING THE STAMP AND SIGNATURE OF THE PROFESSIONALഀ ENGINEER LICENSED IN THE STATE OF COLORADO, AND EMPLOYED BY THE STEELഀ FABRICATOR, FOR ALL CONNECTIONS NOT COMPLETELY DETAILED ON THE STRUCTURALഀ DRAWINGS.AND FOR ANY PROPOSED ALTERNATE CONNECTION DETAILS.ഀ E. ALL WELDERS SHALL HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETYഀ STANDARD QUALIFICATIONS TESTS AS OUTLINED IN AWS-D1.1.ഀ F. MINIMUM WELDS TO BE PER AISC TABLE J2.4 BUT NOT LESS THAN 3/16" CONTINUOUSഀ FILLET UNLESS NOTED OTHERWISE.ഀ G. FOR ALL BEAM/COLUMN OR BEAM/BEAM CONNECTIONS, PROVIDE HORIZONTAL SHORTഀ SLOTS IN CONNECTION MEMBER ONLY (WT-SECTIONS, ANGLES OR SHEAR PLATES).ഀ H. STRUCTURAL STEEL SUPPLIER TO FURNISH LINTELS FOR ALL MASONRY OPENINGS PERഀ LOOSE LINTEL SCHEDULE OR AS SHOWN OTHERWISE ON STRUCTURAL DRAWINGS. ONEഀ END OF THE LINTEL SHALL BE FREE TO MOVE HORIZONTALLY TO ALLOW FORഀ ELONGATION AND SHORTENING.ഀ 1. THE TERMINOLOGY "CONTINUOUS" MEANS QUANTITY. PROVIDE THE NECESSARY JOINTഀ DETAILS TO ALLOW FOR BUILDING MOVEMENTS. COORDINATE LOCATIONS WITHഀ ARCHITECTURAL CONTROL AND EXPANSION JOINTS.ഀ J. PROVIDE ANCHOR BOLTS FOR BEAMS BEARING ON MASONRY UNLESS OTHERWISEഀ NOTED.ഀ K. PROVIDE TEMPORARY BRACING AND PRECAUTIONS NECESSARY TO COMPLY WITH ALLഀ STEEL ERECTION STANDARDS AND TO WITHSTAND ALL CONSTRUCTION AND/OR LATERALഀ LOADS UNTIL ALL FIELD CONNECTIONS ARE COMPLETED AND PERMANENT LATERAL SYSTEMSഀ AND DECKS ARE IN PLACE.ഀ L. STEEL FABRICATOR SHALL NOT RECEIVE ADDITIONAL COMPENSATION FOR SHOPഀ 10ഀ DRAWING TIME FOR ANY REVISIONS TO ERECTION DRAWINGS NOR FOR ANY REVISIONSഀ TO PIECE DRAWINGS PRIOR TO ENGINEER'S APPROVAL OF ERECTION DRAWINGS.ഀ M. UNLESS NOTED OTHERWISE, WHENEVER MASONRY RESTS ON STEEL BEAMS WITHഀ FLANGES NARROWER THAN ACTUAL MASONRY THICKNESS, WELD 1/4" THICKഀ CONTINUOUS PLATE TO BEAM FLANGE. WIDTH OF PLATE TO BE 1/2" NARROWER THANഀ MASONRY THICKNESS.ഀ 11. METAL DECKഀ A. UNLESS NOTED OTHERWISE, DECK SHALL BE SHOP-PAINTED STEEL, SHALL BE OFഀ THE TYPE CALLED FOR ON THE FRAMING PLANS AND SHALL BE TWO SPAN MINIMUM WHEREഀ POSSIBLE.SINGLE SPAN DECK CONDITIONS SHALL BE SHORED. DECK SUPPLIER SHALL VERIFYഀ COMPATIBILITY OF HIS DECK FINISH WITH FIRE PROOFING REQUIREMENTS.ഀ B. DECKING SHALL BE INSTALLED AND ALL OPENINGS IN DECK CUT AND REINFORCED INഀ ACCORDANCE WITH MANUFACTURER'S STANDARD DETAILS AND SPECIFICATIONS'ഀ EXCEPT AS NOTED OTHERWISE.ഀ C. WELDING REQUIREMENTS SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE ON DRAWINGS.ഀ 1. ATTACH ROOF DECK TO SUPPORT BEAMS, STEEL JOISTS OR PLATES WITH'5/8"ഀ PUDDLE WELDS AT 6" (7 WELDS PER SHEET MINIMUM).ഀ 2. LONGITUDINAL JOINTS BETWEEN ADJACENT ROOF DECK UNITS (SIDELAPS) SHALLഀ BE SCREWED PER MANUFACTURER RECOMMENDATIONS AT 3 LOCATION PER SPAN.ഀ 3. ATTACH ROOF DECK TO BEAMS OR PLATES PARALLEL TO DECK WITH 5/8"ഀ DIAMETER PUDDLE WELDS AT 12" ON CENTER.ഀ 4. ATTACH FLOOR DECK TO EACH END SUPPORT AT 12 INCHES AND TO EACHഀ INTERMEDIATE SUPPORT AT SIDE LAPS PLUS ONE INTERMEDIATE POINT WITHഀ 5/8" DIAMETER PUDDLE WELD. PROVIDE WELD WASHERS AS REQUIRED.ഀ 5. LONGITUDINAL JOINTS BETWEEN ADJACENT FLOOR DECK UNITS SHALL BEഀ FASTENED TOGETHER AT 36" MAXIMUM SPACING WITH #10 TEK SCREW FASTEN FLOORഀ DECK TO PARALLEL AND PERIMETER BEAMS AT 12"ON CENTER.ഀ 6. HEADED ANCHOR STUDS SHALL BE WELDED DIRECTLY TO STEEL BEAMSഀ THROUGH DECK.ഀ 12. LIGHT GAGE FRAMINGഀ A. LIGHT-GAGE METAL FRAMING SHALL BE THE SIZE AND GAGE SHOWN ON THEഀ DRAWINGS.ഀ B. FRAMING ROLLED FROM STEEL 18 GAGE AND LIGHTER SHALL CONFORM TO ASTM A570,ഀ LATEST EDITION, WITH A MINIMUM YIELD STRESS OF 33,000 PSI.ഀ C. FRAMING ROLLED FROM STEEL 16 GAGE AND HEAVIER SHALL CONFORM TO ASTM A570,ഀ LATEST EDITION, WITH A MINIMUM YIELD STRESS OF 50,000 PSI.ഀ D. ALL WORK SHALL CONFORM WITH THE RECOGNIZED STANDARDS AND CODES FORഀ LIGHT GAGE METAL FRAMING.ഀ 13. NON-SHRINK GROUTഀ A. NON-SHRINK GROUT SHALL BE PROVIDED:ഀ 1. BETWEEN COLUMN BASES AND CONCRETE OR MASONRY SUPPORTS.ഀ 2. BETWEEN BEAM BEARING PLATES AND CONCRETE OR MASONRYഀ SUPPORTS.ഀ 3. GROUT SHALL BE COMPLETE AND HAVE A MINIMUM COMPRESSIVE STRENGTHഀ OF 6000 PSI PRIOR TO ADDING BUILDING LOADS ABOVE.ഀ 14. WOODഀ A. ALL FRAMING AND TRUSS LUMBER SHALL BE DRY DOUGLAS FIR, LARCH, GRADED BYഀ WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO INTERNATIONAL BUILDINGഀ CODE AS FOLLOWS:ഀ 2" THICK - 4" TO 6" WIDE (WALL STUD ONLY) STUD Fb = 700 PSIഀ 2" TO 4" THICK - 6" AND WIDER NO. 2 Fb = 900 PSIഀ 5" THICK - 5" AND WIDER NO. 1 Fb = 1350 PSIഀ NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NONREPETITVE USES PRIOR TOഀ ALLOWABLE STRESS INCREASES.ഀ GLUMBER IS ALVANIZED (DOUG REQUIRED D PPEOD OR L CONNECTIONS ANDഀ B. WHEN PRESERVATIVE TREATEDഀ NAILING SHALL BE ADEQUATEഀ C. TREATED SILL PLATE LUMBER MAY BE HEM-FIR, STRUCTURAL #1 GRADE.ഀ D. PROVIDE BLOCKING BETWEEN ALL JOISTS AT ARLL BSUPPORTS AND ENDS OF CANTILEVERSഀ SOD ERSഀ IS REQUIRED.ഀ E. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS ACCORDING TO THE IBC SCHEDULEഀ TABLE 2304-9.1 UNLESS NOTED OTHERWISE.ഀ F. LAMINATED BEAMSഀ 1. ALL LAMINATED MEMBERS SHALL BE FABRICATED OF DOUGLAS FIR LARCH PERCENT MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL SIZES SHOWNഀ ARE NET.ഀ 2. LAMINATED MEMBER SHALL BE DETAILED AND FABRICATED IN ACCORDANCEഀ WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OFഀ STRUCTURAL GLUE LAMINATED TIMBER, LATEST EDITION AS PUBLISHED BY AITC.ഀ 3. PROVIDE UNITS CONFORMING TO AITC 117, 24FV8, D.F. FOR CONTINUOUSഀ MEMBERS AND CANTILEVERS AND 24FV4, D.F. FOR SIMPLE SUPPORT MEMBERS.ഀ MEMBERS SHALL BE DESIGNED WITH *ZERO CAMBER WITH TOP SURFACE CLEARLYഀ STAMPED ON EACH MEMBER.ഀ 4. RE: ARCH FOR FINISH REQUIREMENTS.ഀ G. PLYWOOD DECK AND/OR ORIENTED STRAND BOARD.ഀ AMERICAN PLYWOODഀ 1 BE PANELഀ ACCORDANCE WITH RECOMMENDATIONS O OFRTHEI LLഀ ASSOCIATION.ഀ 2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THEഀ AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OFഀ U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELSഀ WHICH HAVE ANY EDGE OR SURFACE PERMANENTLY EXPOSED TO THEഀ WEATHER SHALL BE OF THE EXTERIOR TYPE.ഀ 3 GLUED NAILEDഀ AND WITH 0D NAILS AT 6" ON CENTER ALONG PANEL EDGES AN AT 12" ALONGഀ INTERMEDIATE SUPPORTS.ഀ 4. FOR ROOF USE 5/8" (40/20 SPAN RATING)(UNLESS NOTED OTHERWISE) EXPOSURE Iഀ SHEATHING NAILED WITH 10D NAILS AT 4" ON CENTER ALONG PANEL EDGES ANDഀ AT 12" ALONG INTERMEDIATE SUPPORTS.ഀ ORഀ 5 SHEATHING WITH 8d NAILS AT LAYER 6" OF 1/2" ON CENTER ALONG PLYWOODഀ OSB EATHIING NAഀ 12ഀ EDGES AND 12" ON CENTER AT INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISEഀ AND REFER TO SHEAR WALL SCHEDULE. ALL PANEL EDGES SHALL BE BLOCKED.ഀ 6. FLOORS AND ROOF SHEATHING SHALL BE INSTALLED WITH THE FACE GRAINഀ PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED.ഀ 7. INSTALL SUITABLE EDGE SUPPORT BY USE OF PLYCLIPS, TONGUE ANDഀ GROOVE PANELS OR SOLID WOOD BLOCKING SUPPORTS.ഀ H. PREFABRICATED WOOD MEMBERS SHALL BE THE TYPE NOTED ON THE DRAWINGS ANDഀ SHALL BE "BCI-JOIST" AS MANUFACTURED BY BOISE CASCADE CORPORATION.ഀ ALTERNATES SHALL BE REVIEWED BY THE ENGINEER. TO BE CONSIDERED,ഀ ALTERNATES SHALL HAVE A LOAD CAPACITY IN BENDING, SHEAR AND DEFLECTIONഀ EQUAL TO OR GREATER THAN THE SIZE SHOWN ON THE DRAWINGS. WEB BLOCKINGഀ AND BRIDGING TO BE AS REQUIRED BY THE JOIST MANUFACTURER.ഀ 1. LAMINATED VENEER LUMBER MEMBERS SHALL HAVE THE FOLLOWING STRESSഀ CAPACITIES: FB = 2800 PSI, E = 2,000,000 PSI, FC = 750 PSI, FV = 285 PSI. BUILT UPഀ MEMBERS SHALL BE CONNECTED IN ACCORDANCE WITH MANUFACTURERS'ഀ RECOMMENDATIONS. CONTRACTOR SHALL HAVE THE OPTION OF USING 3 1/2" ORഀ 5 1/4" WIDE MEMBERS.ഀ 15. NON-STRUCTURAL ELEMENTSഀ A. ELEMENTSഀ SUPPORT E INTO ACCOUNT DEFLECTIONS ANDഀ ED BY THE STRUCTURE SHALL TAKഀ OTHER STRUCTURAL MOVEMENTS.ഀ B. FIRE PROTECTION FOR ALL STRUCTURAL PARTS SHALL BE PROVIDED AND SHALL MEETഀ ALL CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED BY THEഀ ARCHITECTURAL DRAWINGS. STRUCTURAL STEEL MEMBERS SHALL BE CONSIDEREDഀ UNRESTRAINED UNLESS NOTED OTHERWISE.ഀ 16. GENERALഀ A. ENGINEER'S ACCEPTANCE MUST BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS.ഀ B. VERIFY ALL OPENINGS THROUGH FLOORS, ROOF AND WALLS WITH MECHANICAL ANDഀ ELECTRICAL CONTRACTORS. VERIFICATION OF LOCATIONS, SIZES, LINTELS ANDഀ REQUIRED CONNECTIONS ARE CONTRACTOR'S COMPLETE RESPONSIBILITY.ഀ C. PRIOR TO INSTALLATION OF MECHANICAL AND ELECTRICAL EQUIPMENT OR OTHERഀ ITEMS TO BE ATTACHED TO THE STRUCTURE, ENGINEER'S APPROVAL OF CONNECTIONSഀ AND SUPPORTS SHALL BE OBTAINED. UNLESS SPECIFICALLY DETAILED ONഀ ARCHITECTURAL AND STRUCTURAL DRAWINGS, RESPECTIVE SUBCONTRACTORഀ SHALL FURNISH ALL HANGERS, CONNECTIONS, ETC., REQUIRED FOR INSTALLATION OFഀ HIS ITEMS.ഀ D. PROVIDE ALL EMBEDDED ITEMS IN STRUCTURE AS NOTED ON ARCHITECTURAL,ഀ MECHANICAL, ELECTRICAL AND STRUCTURAL DRAWINGS. MISCELLANEOUS EMBEDDEDഀ ITEMS AND ANCHOR BOLTS SHALL BE FURNISHED BY STEEL SUPPLIER AND INSTALLEDഀ BY CONCRETE CONTRACTOR. STEEL SHALL FULFILL ASTM A36.ഀ E. PROVIDE ASPHALTIC MASTIC-COATING ON ALL STEEL AND WOOD EXPOSED TO EARTH.ഀ SUBMIT SHOP AND ERECTION DRAWINGS TO ENGINEER FOR REVIEW OF ALL CONCRETEഀ REINFORCING, STRUCTURAL STEEL, LAMINATED WOOD FRAMING MEMBERS, WOODഀ 13ഀ JOISTS, AND METAL DECK. THE MANUFACTURING OR FABRICATION OF ANY ITEMS PRIOR TOഀ WRITTEN REVIEW OF SHOP DRAWINGS WILL BE ENTIRELY AT THE RISK OF THE CONTRACTOR.ഀ Gഀ Hഀ WATERPROOFING, VAPOR BARRIERS, WATERSTOP, ETC., SHALL BE AS SHOWN ON THEഀ ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS.ഀ ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR AND EXTERIORഀ WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE.ഀ ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST FIELD ANDഀ ARCHITECTURAL DRAWINGS.ഀ CONTRACTOR SHALL VERIFY ALL ASSUMED EXISTING CONDITIONS. IF CONDITIONSഀ ARE DIFFERENT THAN ASSUMED, NOTIFY ENGINEER.ഀ K. PRE/MANUFACTURED STAIRS, HANDRAILS, AND GUARDRAILS NOTED ON PLAN SHALL HAVE ALLഀ ENGINEERING, DESIGN AND DETAILING PROVIDED BY STAIR DESIGNER AND SHALL BE SUBMITTEDഀ FOR ARCHITECTS REVIEW BEARING THE SEAL OF A PROFESSIONAL ENGINEER REGISTERED IN THഀ STATE OF COLORADO. STAIRS SHALL BE DESIGNED TO SUPPORT ALIVE LOAD OF 100 PSF. SEEഀ ARCHITECTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS AND CRITERIA.ഀ 14ഀ Vail's Front Doorഀ Lode Addition -Spaഀ Monroe & Newell Engineers Inc. # 5500.02ഀ TABLE OF CONTENTSഀ SET-UP INFORMATIONഀ ROOF BEAM DESIGN RB I - RB47ഀ RB101 -RB141ഀ FLOOR BEAM DESIGN FBI - FB46ഀ FB 101 - FB 150ഀ COLUMN DESIGN Cl - C17ഀ MISCELLANEOUS DESIGN MI-M6ഀ Beam Designഀ 1~ Z~ ► „ ; Iഀ zn/ഀ I 1 I I p 1ഀ x l I ' NON N r Iഀ - - - - -ഀ 1 ~ I II _ (1.ഀ Iഀ I II moo,ഀ 01ഀ 61 ,ഀ I -ഀ ~►O 'ഀ c'ഀ yooഀ to y Iഀ I - ~ t CIOഀ V'bylഀ l.r-- r X Xഀ ~ rlzI tea'ഀ " MYഀ ttJJ ✓ഀ Nഀ 70ഀ io'Vഀ ,ഀ g Iഀ 12ഀ 1ഀ N Iഀ N lid OO~'~,1 ~ V~bX► 0.N jഀ W O X21 N - ~ a 'ഀ O O N cp G Z U X► ..x ' ,ഀ kjklഀ I~ W►2 ► I~`wb v 'ഀ (b 3ഀ W►a -ഀ IIA;ഀ I os, x p l p w12X►`►ഀ ,ഀ (b20Q `3) 1 N Z-~Oഀ W XI O pഀ I ~ ~ N aXx -ഀ tഀ v+ t,'ഀ JLഀ ;ഀ p ' I ec ~ N I ' _ഀ O A X I 1 `I ;1'1ഀ I rnp ~ rn~y~~0 ~ഀ - ~rn I -tx7p~-zഀ S1ഀ Monroe & Newellഀ Engineers, Inc.ഀ JOBഀ SHEET NO.ഀ CALCULATED BYഀ CHECKED BYഀ SCALEഀ ;coo il'ഀ ഀ ഀ ..Y.ഀ 2ഀ AD 5ഀ Q,ഀ rഀ L nA-0 S LUC7i `IrQ P,:;) Ca,t S~....ഀ i,ഀ 41 ~-cഀ Vat/ഀ Tഀ OFഀ DATEഀ DATEഀ sഀ C lU\JLJ~L3ഀ i _ഀ tഀ rഀ Monroe & Newellഀ Engineers, Inc.ഀ aഀ iഀ tiഀ JOB &-u - Sep,ഀ SHEET NO.ഀ CALCULATED BYഀ CHECKED BYഀ SCALEഀ S~ഀ V fi~ 3ഀ OFഀ DATEഀ DATEഀ i~ഀ tom`ഀ Lഀ 4124-ഀ VLഀ Monroe & Newellഀ Engineers, Inc.ഀ JOBഀ SHEET NO.ഀ CALCULATED BY_ഀ CHECKED BYഀ SCALEഀ 'JL <<5s UCsGrkL L.ഀ Monroe & Newellഀ Engineers, Inc.ഀ V(,J -ഀ JOBഀ SHEET NO.ഀ CALCULATED BYഀ CHECKED BYഀ SCALEഀ 3a ~ഀ ?Q 6.ഀ 73ഀ OFഀ DATEഀ DATEഀ fp~Tഀ U- 4,ഀ 111ഀ _ _ഀ ,fഀ -ഀ u~ഀ Ir? R,> Zഀ iഀ C •37ഀ PC)ഀ Monroe & Newellഀ JOBഀ Engineers, Inc.ഀ Aഀ SHEET NO. OF_ഀ CALCULATED BY DATEഀ CHECKED BY DATEഀ SCALEഀ J '9ഀ Monroe & Newell JOBഀ Engineers, Inc. SHEET NO. OFഀ 9ഀ CALCULATED BY DATE 1.2 ate! o~ഀ CHECKED BY DATEഀ SCALEഀ 157:( 9ഀ -ഀ 3sഀ ഀ ഀ k 10ഀ rഀ 1 ~ഀ Q2~ഀ ഀ Qഀ 2 1ഀ 33ഀ arcഀ 01 yoഀ _aഀ 1ഀ J-ഀ 1ഀ 00 nഀ yഀ I..ഀ LJഀ 21rഀ .ഀ 4 17ഀ ഀ ഀ L 4.0.,7 ' 7, (Nv /7'T'ഀ /ഀ --inഀ ഀ ഀ togsഀ 1. n-ഀ 2~ഀ :ഀ ഀ ഀ i A IT% A Aഀ .ഀ 1 Aഀ Y ~ 1z tiഀ 2ഀ c,~ 14 iഀ Aഀ ഀ Iഀ CA<ഀ .ഀ _ _ഀ .............3ഀ ഀ ഀ 2`~~alഀ Wഀ iഀ I'.aഀ 7ഀ Monroe & Newellഀ Engineers, Inc.ഀ Uഀ YC Cif I ~ ~ ~ iഀ `Sഀ JOBഀ SHEET NO.ഀ CALCULATED BY AA- DATE t2-!~ 1,~ഀ CHECKED BYഀ SCALEഀ tzഀ Cഀ Lഀ e3 ~'<Cxr i C~ 1C)ഀ OFഀ DATEഀ `ഀ ULഀ _ I I"ഀ -ഀ Z~.ഀ topഀ p,ഀ t 3 l .~C)ഀ 1Zഀ wr - ~,~15~3ഀ ഀ Iഀ q_zഀ Monroe & Newell JOB VS0 -S?Aഀ Engineers, Inc. SHEET NO. OFഀ q a~ഀ CALCULATED BY ~ DATE(ഀ A iഀ CHECKED BY DATEഀ SCALEഀ P, -ഀ ut `~l4 ~0 ofഀ l~~ v w tഀ I Uഀ a,ഀ 72ഀ 2,3ഀ tMonroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ i' 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, t-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ SSOO.ecw:Roof Beamsഀ Description Roof Beam - RB1ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span I_n_formationഀ Descriptionഀ Spanഀ Cantഀ Span ftഀ 11.00ഀ 3.50ഀ Steel Sectionഀ w8x10ഀ w8x10ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced•Length ftഀ 0.50ഀ 0.50ഀ Loadsഀ Live Load Used This Span ? Yes jഀ Dead Load k/ft 0.120ഀ Live Load k/ft 0.400ഀ Yesഀ 0.120ഀ 0.400ഀ LResultsഀ Mmax @ Cntrഀ k-ftഀ 6.35ഀ 0.00ഀ @ X =ഀ ftഀ 4.91ഀ 3.50ഀ Max @ Left Endഀ lo-ftഀ , 0.00ഀ -3.18ഀ Max @ Right Endഀ k-ftഀ -3.18ഀ 0.00ഀ fb : Actualഀ psiഀ 9,764.5ഀ 4,895.4ഀ Fb : Allowableഀ psiഀ 30 000.0ഀ 30,000.0ഀ fvഀ Aഀ tഀ lഀ Bending OKഀ Bending OKഀ :ഀ cഀ uaഀ psiഀ 2,348.1ഀ 1,356.9ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 2.57ഀ 1.82ഀ Shear @ Rightഀ kഀ 3.15ഀ 0.00ഀ Reactions.:.ഀ DL @ Leftഀ kഀ 0.59ഀ 1.15ഀ LL @ Leftഀ kഀ 1.98ഀ 3.82ഀ Total @ Leftഀ kഀ 2.57ഀ 4.97ഀ DL @ Rightഀ kഀ 1.15ഀ 0.00ഀ LL @ Rightഀ kഀ 3.82ഀ 0.00ഀ Total @ Rightഀ kഀ 4.97ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.145ഀ 0.097ഀ @ X =ഀ ftഀ 5.28ഀ 3.50ഀ Span/Deflection Ratioഀ 907.2ഀ 867.5ഀ Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00ഀ Shear k 2.57 1.82 0.00 0.00 0.00 0.00 0.00 0.00ഀ Moment k-ft 0.00 -3.18 0.00 0.00 0.00 0.00 0.00 0.00ഀ Max. Deflection in 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000ഀ (~~5ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ ' 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB3ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factorഀ 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Span ftഀ 6.50ഀ 2.00ഀ Steel Sectionഀ wsxloഀ wsxloഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 0.50ഀ 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ -ഀ I, SEEMഀ Head Load k/ftഀ 0.105ഀ 0.105ഀ Live Load k/ftഀ 0.350ഀ 0.350ഀ Resultsഀ Mmax @ Cntr k-ftഀ ! 1.97ഀ 0.00ഀ @ X = ftഀ 2.95ഀ 2.00ഀ Max @ Left End k-ftഀ 0.00ഀ -0.91ഀ Max @ Right End k-ftഀ -0.91ഀ 0.00ഀ fb : Actual psiഀ ! 3,027.2ഀ 1,398.7ഀ Fb : Allowable psiഀ 30,000.0ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ ! 1,206.9ഀ 678.4ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 1.34ഀ 0.91ഀ Shear @ Right kഀ 1.62ഀ 0.00ഀ Reactions...ഀ DL @ Left kഀ 0.31ഀ 0.58ഀ LL @ Left kഀ 1.03ഀ 1.95ഀ Total @ Left kഀ 1.34ഀ 2.53ഀ DL @ Right k,ഀ 0.58ഀ 0.00ഀ LL @ Right kഀ 1.95ഀ 0.00ഀ Total @ Right k,ഀ 2.53ഀ 0.00ഀ Max. Deflection inഀ -0.016ഀ 0.011ഀ @X= ftഀ 3.12ഀ 2.00ഀ Span/Deflection Ratioഀ 4,924.4ഀ 4,450.1ഀ Query Valuesഀ 6ഀ Location ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shear kഀ 1.34ഀ 0.91ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Moment k-ftഀ 0.00ഀ -0.91ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflection inഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ X61(,ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ L 303.623.4927ഀ Scopeഀ s Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ve, -Dec-2003ഀ (c)1983-2003 3 ENE ENERCALC LC Engineering g Software l'anഀ Multi-Span Steel Beam Page 1ഀ Qac ai , . 5500 ecw:Rocf Beamsഀ Description Roof Beam - RB4ഀ uenerai information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ inrormatlonഀ Descriptionഀ Span ftഀ Steel Sectionഀ End Fixityഀ Unbraced Length ftഀ Loadsഀ Live Load Used This Span ?ഀ Dead Load k/ftഀ Live Load k/ftഀ Spanഀ 6.50ഀ wsxioഀ Pin-Pinഀ 0.50ഀ -ഀ Cant - -ഀ 2.00ഀ wsx10ഀ Pin-Freeഀ 0.50ഀ Yesഀ Yesഀ 0.135ഀ 0.135ഀ 0.450ഀ 0.450ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 2.53ഀ 0.00ഀ @ X =ഀ Itഀ 2.95ഀ 2.00ഀ Max @ Left Endഀ k-ftഀ l 0.00ഀ -1.17ഀ Max @ Right Endഀ k-ftഀ i -1.17ഀ 0.00ഀ fb : Actualഀ psiഀ 3,892.1ഀ 1,798.3ഀ Fb : Allowableഀ psiഀ 30,000.0ഀ 30,000.0ഀ fv: Actualഀ Bending OKഀ Bending OKഀ psiഀ 1,551.7ഀ 872.3ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ iഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 1.72ഀ 1.17ഀ Shear @ Rightഀ kഀ 2.08ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.40ഀ 0.75ഀ LL @ Leftഀ kഀ 1.32ഀ 2.50ഀ Total @ Leftഀ kഀ 1.72ഀ 3.25ഀ DL @ Rightഀ kഀ 0.75ഀ 0.00ഀ LL @ Rightഀ kഀ 2.50ഀ 0.00ഀ Total @ Rightഀ k Iഀ 3.25ഀ 0.00ഀ Max. Deflectionഀ in;[ഀ -0.020ഀ 0.014ഀ @ X =ഀ ft'ഀ 3.12ഀ 2.00ഀ Span/Deflection Ratioഀ 3,830.1ഀ 3,461.2ഀ Query Valuesഀ Locationഀ Shearഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ Momentഀ kഀ k-ftഀ 1.72ഀ 0.00ഀ 1.17ഀ -1ഀ 17ഀ 0.00ഀ 0ഀ 00ഀ 0.00ഀ 0ഀ 00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ Max. Deflectionഀ in jഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0ഀ 0000ഀ .ഀ 0ഀ 0000ഀ 0.00ഀ 0ഀ 0000ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ .ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ -ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ 7983ഀ 20ഀ ENഀ Rഀ Page 1ഀ (c)ഀ -ഀ 03ഀ CALCഀ Eഀ Engineering Softwareഀ 5500.ecw:Roof Beamsഀ Descriptionഀ Roof Beam - RB6ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ e L-Cantഀ Spanഀ R-Cantഀ Span ftഀ 2.00ഀ 13.00ഀ 2.00ഀ Steel Sectionഀ w12x2eഀ w12x26ഀ w12X26ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 0.50ഀ 0.50ഀ 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.105ഀ 0.105ഀ 0.105ഀ Live Load k/ftഀ 0.350ഀ 0.350ഀ 0.350ഀ Point #1 DL kഀ 2.780ഀ LL kഀ 9.270ഀ @ X ftഀ 6.500ഀ Resultsഀ Mmax @ Cntr k-ftഀ 0.00ഀ 47.86ഀ 0.00ഀ @ X = ftഀ 0.00ഀ 6.50ഀ 2.00ഀ Max @ Left End k-ftഀ ' 0.00ഀ -0.91ഀ -0.91ഀ Max @ Right End k-ftഀ 0.91ഀ -0.91ഀ 0.00ഀ fb : Actual psiഀ 327.1ഀ 17,203.0ഀ 327.1ഀ Fb : Allowable psiഀ ' 33,000.0ഀ 33,000.0ഀ 33,000.0ഀ fv : Actഀ lഀ Bending OKഀ Bending OKഀ Bending OKഀ uaഀ psiഀ 323.8ഀ 3,195.9ഀ 323.8ഀ Fv : Allowable psiഀ 20,000.0ഀ Iഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 8.98ഀ 0.91ഀ Shear @ Rightഀ kഀ 0.91ഀ 8.98ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 2.28ഀ 2.28ഀ LL @ Leftഀ kഀ 0.00ഀ 7.61ഀ 7.61ഀ Total @ Leftഀ kഀ 0.00ഀ 9.89ഀ 9.89ഀ DL @ Rightഀ kഀ 2.28ഀ 2.28ഀ 0.00ഀ LL @ Rightഀ kഀ 7.61ഀ 7.61ഀ 0.00ഀ Total @ Rightഀ k Iഀ 9.89ഀ 9.89ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.095ഀ -0.205ഀ 0.095ഀ @ X =ഀ ft''ഀ 0.00ഀ 6.50ഀ 2.00ഀ Span/Deflection Ratioഀ 505.5ഀ 761.4ഀ 505.4ഀ Query Valuesഀ Location ft 0.00ഀ Shear k 0.00ഀ Moment k-ft 0.00ഀ Max. Deflection in 0.0950ഀ 0.00ഀ 0.00ഀ 8.98ഀ 0.91ഀ -0.91ഀ -0.91ഀ 0.0000ഀ 0.0000ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ rte,;ഀ T Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ i" 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Denver, CO 80202 Description : Lodge Expansionഀ z 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, 1 -Dec-2003ഀ (c)1983-2003 3 ENE NERCALC LC Engineering So Multi-Span Steel Beamഀ ~Software I" •7ഀ Description Roof Beam RB8ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ Page 1ഀ 5500.ecw:Roof Beamsഀ General Informationഀ Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy Yield Stressഀ 50.00 kslഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ UeSCflptlOnഀ I Spanഀ Cantഀ Span ftഀ 9.50ഀ 4.50ഀ Steel Sectionഀ I waxesഀ wsxlsഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ I 0.50ഀ 0.50ഀ Loadsഀ -AMMEMMഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.180ഀ 0.180ഀ Live Load k/ftഀ 0.600ഀ 0.600ഀ Point #1 DL kഀ 0.630ഀ LL kഀ 2.100ഀ @ X ftഀ 4.500ഀ Resultsഀ Mmax @ Cntr k-ftjഀ 1.60ഀ FM-ഀ 0.00ഀ @ X = ft lഀ 2.03ഀ 0.00ഀ Max @ Left End k-ftഀ 0.00ഀ -20.18ഀ Max @ Right End k-ftഀ -20.18ഀ 0.00ഀ fb : Actual psiഀ 15,924.3ഀ 15,924.3ഀ Fb : Allowable psi,ഀ 33,000.0ഀ 33,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 3,113.7ഀ 3,333.0ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 1.58ഀ 6.24ഀ Shear @ Rightഀ kഀ 5.83ഀ 2.73ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.36ഀ 2.79ഀ LL @ Leftഀ kഀ 1.22ഀ 9.28ഀ Total @ Leftഀ kഀ iഀ 1.58ഀ 12.07ഀ DL @ Rightഀ kഀ 2.79ഀ 0.00ഀ LL @ Rightഀ kഀ 9.28ഀ 0.00ഀ Total @ Rightഀ k jഀ 12.07ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.040ഀ -0.274ഀ @ X =ഀ ftഀ 6.78ഀ 4.50ഀ Span/Deflection Ratioഀ 2,876.8ഀ 394.0ഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Shearഀ kഀ 1.58ഀ 6.24ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Momentഀ Maxഀ Deflectionഀ k-ftഀ iഀ Iഀ 0.00ഀ -20.18ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ nഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Rev: 580007ഀ User: KW-0606238,ഀ (c)7983.2003 ENERഀ Descriptionഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ 5.8.0, t-DecSo Multi-Span Steel Beam Page 1ഀ C Engineering Software 5500.ecw:Roof Beamsഀ Roof Beam - RB9ഀ uenerai intormatlonഀ ..:ru:.._.._ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factorഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Spanഀ Spanഀ ftഀ 3.50ഀ 20ഀ 50ഀ Steel Sectionഀ w14x22ഀ .ഀ w14x22ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.50ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Loadഀ k/fഀ I 0.195ഀ 0.195ഀ Live Loadഀ k/ftഀ 1 0.650ഀ 0ഀ 650ഀ Point #1 DLഀ kഀ .ഀ 1ഀ 710ഀ LLഀ kഀ iഀ .ഀ 5.720ഀ @ Xഀ ftഀ 20.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 43.77ഀ OQ X =ഀ ftഀ 0.00ഀ 10.80ഀ Max @ Left Endഀ k-ftlഀ 0.00ഀ -5.18ഀ Max @ Right Endഀ k-ft l'ഀ -5.18ഀ 0.00ഀ fb : Actualഀ psiഀ 21144.1ഀ 18,132.4ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 29,568.6ഀ fv : Actualഀ Bending OKഀ Bending OKഀ Fv :Allowableഀ psiഀ psiഀ 935.9ഀ 20,000.0ഀ 4,954.6ഀ 20,000.0ഀ 1.00ഀ Shear @ Leftഀ kഀ 0.00ഀ 9ഀ 09ഀ Shear @ Rightഀ kഀ 2.96ഀ .ഀ 15.66ഀ 7ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 2ഀ 78ഀ LL @ Leftഀ kഀ 0.00ഀ .ഀ 9.27ഀ Total @ Leftഀ kഀ 0.00ഀ 12.05ഀ DL @ Rightഀ k Iഀ 2.78ഀ 3ഀ 61ഀ LL @ Rightഀ k Iഀ 9.27ഀ .ഀ 12.05ഀ Total @ Rightഀ k jഀ 12.05ഀ 15.66ഀ Max. Deflectionഀ inഀ 0.288ഀ -0.570ഀ @ X=ഀ ft;ഀ 0.00ഀ 10.39ഀ Span/Deflection Ratioഀ Iഀ 292.0ഀ 431.2ഀ query Valuesഀ Locationഀ Shearഀ Momentഀ Max. Deflectionഀ ft lഀ 0.00ഀ o.00ഀ 0.00ഀ 0.00ഀ kഀ 0.00ഀ 9.09ഀ 0.00ഀ 0.00ഀ k-ftഀ 0.00ഀ 5.18ഀ 0.00ഀ 0.00ഀ in ~ഀ 0.2877ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ 0.00 wഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 2s3~ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Aഀ thഀ Aഀ hഀ thഀ PEഀ Dഀ Job # 5500.02ഀ 10ഀ 32AMഀ 14 DEC 05ഀ Dഀ 1701 Wynkoop Street, Suite 200ഀ urഀ sഀ worഀ ,ഀ sgnr:ഀ rഀ :ഀ ,ഀ ate:ഀ Denver, CO 80202ഀ Description :Lodge Expansionഀ zഀ ~ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 11 Aഀ User: Kw-0606238, Ver5.8.0, 1-Dec-2C03 Multi-Span Steel Beamഀ Page 1ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ 5500.ecw:Roof Beamsഀ Descriptionഀ Roof Beam - RB10ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 'ഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Contiഀ nuous Over Supportsഀ Span Informationഀ Pഀ Descriptionഀ L-Cantഀ L-Spanഀ R-Spanഀ L R-Cantഀ Span ftഀ 3.50ഀ 10.50ഀ 20.00ഀ 3.50ഀ Steel Sectionഀ W34X26ഀ W14x26ഀ W14X26ഀ W14X26ഀ End Fixity .ഀ Free-Pinഀ Pin-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 3.50ഀ 5.00ഀ 5.00ഀ 3.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Yesഀ Dead Load ' k/ftഀ 0.150ഀ 0.120ഀ 0.345ഀ 0.345ഀ Live Load k/ftഀ 0.500ഀ 0.400ഀ 1.150ഀ 1.150ഀ Point #1 DL kഀ 3.610ഀ LL kഀ 12.050ഀ @ X ftഀ 6.500ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 7.73ഀ 42.91ഀ 0.00ഀ @ X =ഀ ftഀ 0.00ഀ 6.44ഀ 11.60ഀ 3.50ഀ Max @ Left Endഀ k-ft'ഀ 0.00ഀ -3.98ഀ -58.60ഀ -9.16ഀ Max @ Right Endഀ k-ftഀ -3.98ഀ -58.60ഀ -9.16ഀ 0.00ഀ fb : Actualഀ psi,ഀ 1,356.2ഀ 19,963.2ഀ 19,963.2ഀ 3,119.3ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 30,000.0ഀ 30,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 641.4ഀ 4,969.3ഀ 4,911.8ഀ 1,475.2ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions.& Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 3.49ഀ 17.42ഀ 5.23ഀ Shear @ Rightഀ kഀ 2.27ഀ 17.63ഀ 12.48ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 1.33ഀ 8.09ഀ 4.09ഀ LL @ Leftഀ kഀ 0.00ഀ 4.44ഀ 26.96ഀ 13.62ഀ Total @ Leftഀ kഀ 0.00ഀ 5.77ഀ 35.05ഀ 17.71ഀ DL @ Rightഀ kഀ 1.33ഀ 8.09ഀ 4.09ഀ 0.00ഀ LL @ Rightഀ kഀ 4.44ഀ 26.96ഀ 13.62ഀ 0.00ഀ Total @ Rightഀ kഀ 5.77ഀ 35.05ഀ 17.71ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.001ഀ 0.015ഀ -0.350ഀ 0.201ഀ @ X =ഀ ft'ഀ 0.00ഀ 8.68ഀ 10.93ഀ 3.50ഀ Span/Deflection Ratioഀ 90,995.9ഀ 8,520.9ഀ 684.9ഀ 417.9ഀ Querv Valuesഀ Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00ഀ Shear k 0.00 3.49 17.42 5.23 0.00 0.00 0.00 0.00ഀ Moment k-ft 0.00 -3.98 -58.60 -9.16 0.00 0.00 0.00 0.00ഀ Max. Deflection in -0.0009 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000ഀ U' Z1ഀ t Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ ` 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB11ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Span Itഀ 10.00ഀ 4.50ഀ Steel Sectionഀ wsxloഀ waxioഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 0.50ഀ 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Dead Load k/ftഀ Live Load k/ftഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ k-ftഀ ftഀ k-ftഀ k-ftഀ psiഀ psiഀ psiഀ psiഀ Yes Yesഀ 0.060 0.060ഀ 0.200 0.200ഀ 2.07ഀ 0.00ഀ 4.00ഀ 0.00ഀ 0.00ഀ -2.63ഀ -2.63ഀ 0.00ഀ 4,046.2ഀ 4,046.2ഀ 30,000.0ഀ 30,000.0ഀ Bending OKഀ Sending OKഀ 1,165.5ഀ 872.3ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 1.04ഀ 1.17ഀ Shear @ Rightഀ kഀ 1.56ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.24ഀ 0.63ഀ LL @ Leftഀ kഀ 0.80ഀ 2.10ഀ Total @ Leftഀ kഀ 1.04ഀ 2.73ഀ DL @ Rightഀ k,ഀ 0.63ഀ 0.00ഀ LL @ Rightഀ k'ഀ 2.10ഀ 0.00ഀ Total @ Rightഀ kഀ 2.73ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.034ഀ -0.008ഀ @ X =ഀ ftഀ 4.47ഀ 4.50ഀ Span/Deflection Ratioഀ 3,503.8ഀ 13,230.6ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 1.04ഀ 1.17ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -2.63ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 52"ഀ Monroe & Newell Engineers, Inc.ഀ r, 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Scope:ഀ nev: oouuuiഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam RB12ഀ Multi-Span Steel Beamഀ Page 1ഀ 5500.ecw:Roof Beamsഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 .ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factorഀ V1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ D2SCCIpt10nഀ Spanഀ Cantഀ Span ftഀ 3.50ഀ 3.50ഀ Steel Sectionഀ wlox12ഀ W10x12ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 3.50ഀ 3.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.195ഀ 0.195ഀ Live Load k/ftഀ 0.600ഀ 0.600ഀ Resultsഀ Mmax @ Cntr k-ftഀ 0.00ഀ 0.00ഀ @ X = ftഀ 0.00ഀ 3.50ഀ Max @ Left End k-ftഀ 0.00ഀ -4.87ഀ Max @ Right End k-ftഀ -4.87ഀ 0.00ഀ fb : Actual psiഀ 5,359.9ഀ 5,359.9ഀ Fb : Allowable psiഀ 30,000.0ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 1,483.8ഀ 1,483.8ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ @ Left kഀ 0.00ഀ 2.78ഀ @ Right kഀ 7ഀ 2.78ഀ 0.00ഀ Reactionsഀ ഀ @ Left kഀ 0.ഀ 00ഀ 136ഀ LL @ Left kഀ 0.00ഀ 4.20ഀ Total @ Left kഀ 0.00ഀ 5.56ഀ DL @ Right kഀ 1.36ഀ 0.00ഀ LL @ Right kഀ 4.20ഀ 0.00ഀ Total @ Right kഀ 5.56ഀ 0.00ഀ Max. Deflection inഀ 0.003ഀ -0.033ഀ @ X = ftഀ 2.19ഀ 3.50ഀ Span/Deflection Ratioഀ 16,146.9ഀ 2,536.4ഀ LQuery Valuesഀ Location ft jഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ 0.00ഀ Shear kഀ 0.00ഀ 2.78 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ 0.00ഀ Moment k-ft iഀ 0.00ഀ -4.87 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ 0ഀ 00ഀ Max. Deflection in 1ഀ 0.0000ഀ 0.0000 0.0000ഀ 0.0000ഀ 0.0000 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ Q a 5ഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ rഀ Fax: 303.623.6602ഀ ~ iഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ User: Kw-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Design Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 9ഀ SSOO.ecw:Roof Beamsഀ Description Roof Beam - RB13ഀ wഀ 3ummaryഀ Beam OKഀ Using: W8X10 section, Span = 5.OOft, Fy = 50.Oksiഀ Static Load Caseഀ Governs Stressഀ End Fixity = Pinned-Pinned, Luഀ = 5.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ fb : Bending Stressഀ 6.981 k-ftഀ 10.727 ksiഀ 17.788 k-ftഀ 27.332 ksiഀ Max. Deflectionഀ -0.028 inഀ fb / Fbഀ 0.392: 1ഀ Length/DL Deflഀ 8,559.3: 1ഀ Length/(DL+LL Defl)ഀ 2,130.0: 1ഀ Shearഀ 2.805 kഀ 26.826 kഀ fv : Shear Stressഀ 2.091 ksiഀ 20.000 ksiഀ fv / Fvഀ 0.105 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as notedഀ DLഀ LL LL+ST LL LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cants @ Cantsഀ Max. M + 6.98 k-ftഀ 1.73ഀ 6.98 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 2.81 kഀ 0.71ഀ 2.81 kഀ Shear @ Right 2.81 kഀ 0.71ഀ 2.81 kഀ Center Defl.ഀ -0.028 inഀ -0.007ഀ -0.028ഀ Left Cant Deftഀ 0.000inഀ 0.000ഀ 0.000ഀ Right Cant DOഀ 0.000 inഀ 0.000ഀ 0.000ഀ ...Query Defl @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ Reaction @ Left 2.81 0.71 2.81ഀ Reaction @ Rt 2.81 0.71 2.81ഀ Fa calc'd per Eq. E2-2, K'Ur > Ccഀ I Beam, Major Axis, (102,000 ` Cb / Fy)A.5 UrT (510,000' Cb / Fy)A.5 , Fbഀ Section Properties W8X10ഀ -0.028ഀ 0.000ഀ 0.000ഀ 0.000ഀ 2.81ഀ 2.81ഀ rEq. F1-6ഀ 0.000 0.000 inഀ 0.000 0.000 inഀ 0.000 0.000 inഀ 0.000 0.000 inഀ kഀ kഀ Depthഀ 7.890 inഀ Weightഀ 10.05 #/ftഀ Web Thickഀ 0.170 inഀ Ixxഀ 30.800 in4ഀ Widthഀ 3.940 inഀ lyyഀ 2.090 in4ഀ Flange Thickഀ 0.205 inഀ Sxxഀ 7.810 in3ഀ Areaഀ 2.96 in2ഀ Syyഀ 1.060 in3ഀ Rtഀ 0.990 inഀ R-xxഀ 3.220 inഀ Values for LRFD Design....ഀ R-YYഀ 0.841 inഀ Jഀ 0.040 in4ഀ Zxഀ 8.870 in3ഀ Cwഀ 30.90 in6ഀ ZYഀ 1.660 in3ഀ Kഀ 0.505 inഀ t Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ Ds nr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ 1701 Wynkoop Street, Suite 200 9ഀ Denver, CO 80202 Description :Lodge Expansionഀ 303.623.4927ഀ Scope:ഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, t-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983.2003 ENERCA~C Engineering Software - 5500.ecw:Roof Beamsഀ Description Roof Beam - RB14ഀ General Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ FYield Stress 50.00 ksc~^1Tഀ Y i Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Span ftഀ 3.50ഀ 3.50ഀ Steel Sectionഀ wsxioഀ w8x10ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 3.50ഀ 3.50ഀ Loadsഀ Live Load Used This Span ?ഀ i Yesഀ Yesഀ Dead Load Witഀ 0.158ഀ 0.158ഀ Live Load k/ftഀ 0.525ഀ 0.525ഀ Resultsഀ Mmax @ Cntr k-ftഀ ~ 0.00 1ഀ =ഀ 0.0ഀ 00ഀ -ഀ ~ഀ ഀ @ X = ftഀ 0.00ഀ 3.50ഀ Max @ Left End k-ftഀ 0.00ഀ -4.18ഀ Max @ Right End k-ftഀ ; -4.18ഀ 0.00ഀ fb : Actual psiഀ 6,429.9ഀ 6,429.9ഀ Fb : Allowable psiഀ 30,000.0ഀ 30,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 1,782.2ഀ 1,782.2ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.00ഀ 2.39ഀ Shear @ Right kഀ 2.39ഀ 0.00ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 1.11ഀ LL @ Left kഀ 0.00ഀ 3.67ഀ Total @ Left kഀ 0.00ഀ 4.78ഀ DL @ Right kഀ 1.11ഀ 0.00ഀ LL @ Right k'ഀ 3.67ഀ 0.00ഀ Total @ Right kഀ 4.78ഀ 0.00ഀ Max. Deflection inഀ lഀ 0.004ഀ -0.050ഀ @ X= ftഀ 2.19ഀ 3.50ഀ Span/Deflection Ratioഀ 10,759.8ഀ 1,690.1ഀ Query Valuesഀ Location ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Shear kഀ 0.00ഀ 2.39ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Moment k-ftഀ Maxഀ Deflection iഀ 0.00ഀ 4.18ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ n Iഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 2b zGഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Tlഀ 1701 Wynkooഀ p Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description :Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User : KW-060623 5ഀ 8, Ver.8.0, t-Dec-2003ഀ 98 se, 3ഀ Uഀ 0ഀ MUItI-Span Steel Beam Page 1ഀ (cഀ -2ഀ 03 ENERCAL Engineering Softwareഀ 5500.ecw:Roof Beamsഀ Description Roof Beam - RB16ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Consideredഀ Continuous Over Supഀ portsഀ Span Informationഀ Descriptionഀ spanഀ cantഀ Spanഀ ftഀ ' 11.00ഀ 2.00ഀ Steel Sectionഀ wioxisഀ MOMSഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Lengthഀ ftഀ 5.00ഀ 2.00ഀ Loadsഀ Live Load Used this Span ?ഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.158ഀ 0.158ഀ Live Loadഀ k/ftഀ 0.525ഀ 0.525ഀ Point #1 DLഀ kഀ 2.790ഀ LLഀ kഀ 9.280ഀ @ Xഀ ftഀ 2.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ l 1.51ഀ 0.00ഀ @ X =ഀ ftഀ 2.13ഀ 2.00ഀ Max @ Left Endഀ k-ft'ഀ 0.00ഀ -25.51ഀ Max @ Right Endഀ k-ftഀ -25.51ഀ 0.00ഀ fb : Actualഀ psi,ഀ 22,189.1ഀ 22,189.1ഀ Fb : Allowableഀ psi'ഀ 27,331.5ഀ 33,000.0ഀ fv : Actualഀ psiഀ Bending OKഀ 2,644.0ഀ Bending OKഀ 5,847.6ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 1.44ഀ 13.44ഀ Shear @ Right kഀ 6.08ഀ 12.07ഀ Reactions...ഀ DL @ Left kഀ 0.33ഀ 4.51ഀ LL @ Left kഀ 1.10ഀ 15.00ഀ Total @ Left kഀ 1.44ഀ 19.51ഀ DL @ Right kഀ 4.51ഀ 0.00ഀ LL @ Right kഀ 15.00ഀ 0.00ഀ Total @ Right k iഀ 19.51ഀ 0.00ഀ Max. Deflection- inഀ 0.067ഀ -0.126ഀ ,ഀ @ X = ftഀ 7.63ഀ 2.00ഀ Span/Deflection Ratioഀ 1,962.5ഀ 382.1ഀ Query Valuesഀ Location ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shear kഀ 1.44ഀ 13.44ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Moment k-ft'ഀ 0.00ഀ -25.51ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflection in Iഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Q • J / ;ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ Rev: 580007ഀ User: KW-0606238,ഀ Descriptionഀ 1-Dec-2003ഀ neering Softwareഀ Roof Beam - RB17ഀ Multi-Span Steel Beamഀ Page 1ഀ 5500.ecw:Roof Beamsഀ General Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Span ftഀ 11.50ഀ 9.00ഀ Steel Sectionഀ w12x22ഀ w12x22ഀ End Fixity -ഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 5.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.270ഀ 0.270ഀ Live Load k/ftഀ 0.900ഀ 0.900ഀ Point #1 DL kഀ 1.350ഀ LL kഀ 4.500ഀ @ X ftഀ 3.500ഀ _ഀ Resultsഀ Mmax @ Cntr k-ftlഀ 16.11ഀ 0.00ഀ @ X = ftഀ 3.53ഀ 0.00ഀ Max @ Left End k-ftഀ 0.00ഀ -47.38ഀ Max @ Right End k-ftഀ -47.38ഀ 0.00ഀ fb : Actual psiഀ 22,435.0ഀ 22,435.0ഀ Fb : Allowable psiഀ 27,679.4ഀ 27,679.4ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 3,945.6ഀ 3,290.0ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 6.68ഀ 10.53ഀ Shear @ Rightഀ kഀ ' 12.63ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 1.54ഀ 5.34ഀ LL @ Leftഀ kഀ 5.14ഀ 17.81ഀ Total @ Leftഀ kഀ 6.68ഀ 23.16ഀ DL @ Rightഀ kഀ 5.34ഀ 0.00ഀ LL @ Rightഀ kഀ 17.81ഀ 0.00ഀ Total @ Rightഀ kഀ 23.16ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.025ഀ -0.613ഀ @ X =ഀ ftഀ ! 9.43ഀ 9.00ഀ Span/Deflection Ratioഀ 5,551.2ഀ 352.6ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 6.68ഀ 10.53ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ -0.00ഀ -47.38ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ i 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ C-16IZ 1ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ ,;r: i<W-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ 1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB19ഀ Page 1ഀ 5500.ecw:Roof Beamsഀ General Informationഀ Code e : AISC 9th ASD 1997 UBC 2003 IBC, 2003 NFPAഀ 5000 -ഀ 'camഀ Steel Section : W12X26ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 7.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 3.00 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads. .ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ DL 0.805ഀ k/ftഀ LL 0.700ഀ k/ftഀ STഀ k/ftഀ Start Location 3.000ഀ ftഀ End Location 7.000ഀ ftഀ Point Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ Dead Load 8.090ഀ kഀ Live Load 26.960ഀ kഀ Short Termഀ kഀ Location 3.000ഀ ftഀ 7Mഀ Summaryഀ Wഀ Beam OKഀ Stഀ tiഀ Lഀ d Cഀ Gഀ Sഀ Using: Wt 2X26 section, Spanഀ = 7.00ft, Fy = 50.Oksiഀ aഀ cഀ oaഀ aseഀ overnsഀ tressഀ End Fixity = Pinned-Pinned, Lഀ u = 3.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 65.315 k-ftഀ 91.850 k-ftഀ Max. Deflectionഀ -0.080 inഀ fb : Bending Stressഀ 23.466 ksiഀ 33.000 ksiഀ Length/DL DOഀ 3,971.4: 1ഀ fb / Fbഀ 0.711 : 1ഀ Length/(DL+LL Defl)ഀ 1,052.6 :1ഀ Shearഀ 21.840 kഀ 56.212 kഀ fv : Shear Stressഀ 7.770 ksiഀ 20.000 ksiഀ fv / Fvഀ 0.389 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as notedഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 65.31 k-ftഀ 16.76ഀ 65.31ഀ k-ftഀ Max. M -ഀ -0.00ഀ -0.00ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 21.84 kഀ 5.63ഀ 21.84ഀ kഀ Shear @ Right 19.41 kഀ 5.86ഀ 19.41ഀ kഀ Center Defl. -0.080 inഀ -0.021ഀ -0.080ഀ -0.080ഀ 0.000ഀ 0.000 inഀ Left Cant DefI 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 21.84ഀ 5.63ഀ 21.84ഀ 21.84ഀ kഀ Reaction @ Rt 19.41ഀ 5.86ഀ 19.41ഀ 19.41ഀ kഀ Fa calc'd per Eq. E2-1, K'L/r < Ccഀ I Beam Passes Table B5.1, Fb per Eq. F1ഀ -1, Fb = 0.66 Fyഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Pageഀ 2ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB19ഀ Section Propertiesഀ W1 2X26ഀ Depthഀ 12.220 inഀ Weightഀ 25.98 #/ftഀ Web Thickഀ 0.230 inഀ Ixxഀ 204.000 in4ഀ Widthഀ 6.490 inഀ lyyഀ 17.300 in4ഀ Flange Thickഀ 0.380 inഀ Sxxഀ 33.400 in3ഀ Areaഀ 7.65 in2ഀ Syyഀ 5.340 in3ഀ Rtഀ 1.720 inഀ R-xxഀ 5.170 inഀ Values for LRFD Design....ഀ R-yyഀ 1.510 inഀ Jഀ 0.300 in4ഀ Zxഀ 37.200 in3ഀ Cwഀ 606.00 in6ഀ Zyഀ 8.170 in3ഀ Kഀ 0.680 inഀ (7. n c^.ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 pഀ User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB20ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Spanഀ Right Cantഀ Spanഀ ftഀ 2.00ഀ 6.00ഀ 6.00ഀ Steel Sectionഀ w12x14ഀ w12x14ഀ w12x14ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Lengthഀ ftഀ 2.00ഀ 4.00ഀ 4.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.805ഀ 0.805ഀ 0.805ഀ Live Loadഀ k/ftഀ 0.700ഀ 0.700ഀ 0.700ഀ Resultsഀ Mmax @ Cntrഀ k-ft!ഀ 0.00ഀ 0.00ഀ 0.00ഀ @ X =ഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -3.01ഀ -27.09ഀ Max @ Right Endഀ k-ftഀ -101ഀ -27.09ഀ 0.00ഀ fb : Actualഀ psiഀ 2,427.7ഀ 21,849.3ഀ 21,849.3ഀ Fb:Allowableഀ psi!ഀ 33,000.0ഀ 29,161.9ഀ 29,161.9ഀ Bending OKഀ Sending OKഀ Bending OKഀ fv : Actualഀ psiഀ 1,263.6ഀ 3,580.3ഀ 3,790.9ഀ Fv : Allowableഀ psi;ഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 0.50ഀ 9.03ഀ Shear @ Rightഀ kഀ 3.01ഀ 8.53ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 1.88ഀ 9.39ഀ LL @ Leftഀ kഀ . 0.00ഀ 1.63ഀ 8.17ഀ Total @ Leftഀ kഀ 0.00ഀ 3.51ഀ 17.56ഀ DL @ Rightഀ kഀ 1.88ഀ 9.39ഀ 0.00ഀ LL @ Rightഀ kഀ 1.63ഀ 8.17ഀ 0.00ഀ Total @ Rightഀ kഀ 3.51ഀ 17.56ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.029ഀ 0.030ഀ -0.339ഀ @ X =ഀ ftഀ 0.00ഀ 3.64ഀ 6.00ഀ Span/Deflection Ratioഀ 1,680.5ഀ 2,416.6ഀ 424.3ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 0.50ഀ 9.03ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -3.01ഀ -27.09ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in Iഀ -0.0286ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ } Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB21ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Left Spanഀ Spanഀ ftഀ 7.50ഀ 16.00ഀ Steel Sectionഀ w12X14ഀ W12x14ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 4.00ഀ 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.165ഀ 0.165ഀ Live Loadഀ k/ftഀ 0.550ഀ 0.550ഀ DL @ Leftഀ k/ftഀ DL @ Rightഀ k/ftഀ 0.135ഀ LL @ Leftഀ k/ftഀ LL @ Rightഀ k/ftഀ Startഀ ftഀ 2.000ഀ Endഀ ftഀ 16.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ l 0.00ഀ 15.87ഀ @X=ഀ ftഀ 0.00ഀ 9.71ഀ Max @ Left Endഀ k-ftഀ ' 0.00ഀ -20.11ഀ Max @ Right Endഀ k-ftഀ -20.11ഀ 0.00ഀ fb : Actualഀ psiഀ 16,219.1ഀ 16,219.1ഀ Fb : Allowableഀ psiഀ 29,161.9ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 2,251.3ഀ 3,044.7ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 7.25ഀ Shear @ Rightഀ kഀ 5.36ഀ 5.13ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 3.12ഀ LL @ Leftഀ k (ഀ 0.00ഀ 9.49ഀ Total @ Leftഀ kഀ 0.00ഀ 12.61ഀ DL @ Rightഀ kഀ 3.12ഀ 1.70ഀ LL @ Rightഀ k Iഀ 9.49ഀ 3.43ഀ Total @ Rightഀ k iഀ 12.61ഀ 5.13ഀ Max. Deflectionഀ inഀ -0.068ഀ -0.232ഀ @ X =ഀ ftഀ 0.00ഀ 8.96ഀ Span/Deflection Ratioഀ 2,658.2ഀ 828.5ഀ Query Valuesഀ Locationഀ Shearഀ Momentഀ Max. Deflectionഀ Xഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ kഀ 0.00ഀ 7.25ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ k-ftഀ 0.00ഀ -20.11ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ in;ഀ -0.0677ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Descriptionഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Roof Beam - RB22ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope:ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ General Information ,Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W12X14 Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Span 10.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 ft LL & ST Act Togetherഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 4.00 ftഀ Distributed Loads Note! Short Term Loads Are WIND Loads.ഀ #1 #2 #3 #4 #5 #6 #7ഀ DL 0.805 k/ftഀ LL 0.700 k/ftഀ ST k/ftഀ Start Location ftഀ End Location • 10.000 ftഀ Point Loads Note! Short Term Loads Are WIND Loads.ഀ #1 #2ഀ Dead Loadഀ 1.700 0.950ഀ Live Loadഀ 3.430 3.170ഀ Short Termഀ Locationഀ 7.500 8.000ഀ #3ഀ #4ഀ #5ഀ #6ഀ #7ഀ kഀ kഀ kഀ ftഀ Using: W 12X14 section, Span= 10.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 4.00ft, LDF = 1.000ഀ Actual Allowableഀ Moment 30.982 k-ft 36.209 k-ftഀ fb : Bending Stress 24.952 ksi 29.162 ksiഀ fb / Fb 0.856 : 1ഀ Shear 14.739 k 47.640 kഀ fv Shear Stress 6.188 ksi 20.000 ksiഀ fv / Fv 0.309 :1ഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.216 inഀ Length/DL Defl 1,253.1 :1ഀ Length/(DL+LL Defl) 556.2 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 30.98 k-ft 13.54 30.98 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 9.70 kഀ 4.71ഀ 9.70ഀ kഀ Shear @ Right 14.74 kഀ 6.13ഀ 14.74ഀ kഀ Center Defl. -0.216 inഀ -0.096ഀ -0.216ഀ -0.216ഀ 0.000ഀ 0.000 inഀ Left Cant DO 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 9.70ഀ 4.71ഀ 9.70ഀ 9.70ഀ kഀ Reaction @ Rt 14.74ഀ 6.13ഀ 14.74ഀ 14.74ഀ kഀ Fa calc'd per Eq. E2-2, K*L/r > Ccഀ I Beam, Major Axis, (102,000 * Cb / Fy)A.ഀ 5 L/rT (510,ഀ 000 * Cb / Fy)A.5ഀ , Fb per Eq. F1-6ഀ 2rf?,ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ tഀ 303.623.4927ഀ t:ഀ Fax: 303.623.6602 Scopeഀ Rev: 580006ഀ User: 060E38,Ver5.8.0,7-DecS of Designഀ (c)19833--22003 ENERCALC Engineeringg Software S Jteel Beam Page 2ഀ SSOO.ecw:Root Beamsഀ Description Roof Beam - RB22ഀ Section Properties W12X14ഀ Depthഀ Web Thickഀ 11.910 inഀ Weightഀ 14.13 #/ftഀ 0.200 inഀ Ixxഀ 88.600 in4ഀ Widthഀ 3.970 inഀ lyyഀ 2ഀ 360 in4ഀ Flange Thickഀ 0.225 inഀ Sxxഀ .ഀ 14ഀ 900 in3ഀ Areaഀ 4.16 in2ഀ Syyഀ .ഀ 1.190 in3ഀ Rtഀ 0.950 inഀ R-ഀ 4.620 inഀ Values for LRFD Design....ഀ R-yyഀ 0.753 inഀ Jഀ 0.070 in4ഀ Zxഀ 17.400 in3ഀ Cwഀ 80.60 in6ഀ Zyഀ 1.900 in3ഀ Kഀ 0.525 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ tlഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ R- RRnnn7ഀ Span Informationഀ Descriptionഀ Span ftഀ Steel Sectionഀ End Fixityഀ Unbraced Length ftഀ Loadsഀ Live Load Used This Span ?ഀ Dead Load k/ftഀ Live Load k/ftഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ Spanഀ Cantഀ 16.00ഀ 1.50ഀ wax21ഀ wsx21ഀ Pin-Pinഀ Pin-Freeഀ 0.50ഀ 1.50ഀ Yesഀ Yesഀ 0.120ഀ 0.120ഀ 0.400ഀ 0.400ഀ k-ftഀ Jഀ 16.35ഀ 0.00ഀ ftഀ 7.89ഀ 0.00ഀ k-ftഀ 0.00ഀ -0.58ഀ k-ftഀ -0.58ഀ 0.00ഀ psiഀ 10,786.1ഀ 386.0ഀ psiഀ ,ഀ 33,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ psiഀ 2,027.3ഀ 376.8ഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 4.12ഀ 0.78ഀ Shear @ Right kഀ 4.20ഀ 0.00ഀ Reactions...ഀ DL @ Left kഀ 0.95ഀ 1.15ഀ LL @ Left kഀ 3.17ഀ 3.83ഀ Total @ Left kഀ 4.12ഀ 4.98ഀ DL @ Right kഀ 1.15ഀ 0.00ഀ LL @ Right k Iഀ 3.83ഀ 0.00ഀ Total @ Right kഀ 4.98ഀ 0.00ഀ Max. Deflection in Iഀ in'ഀ -0.344ഀ 0.101ഀ @ X = ftഀ 8.00ഀ 1.50ഀ Span/Deflection Ratioഀ 558.6ഀ 356.7ഀ Query Valuesഀ Location ft lഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Shear kഀ 4.12ഀ 0.78ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Moment k-ftഀ -0.00ഀ -0.58ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Max. Deflection inഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ tഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ 5500.ecw:Roof Beamsഀ Description Roof Beam - RB27ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cant Spanഀ Span ftഀ 3.00 16.00ഀ Steel Sectionഀ WlOx22 W10X22ഀ End Fixityഀ Free-Pin Pin-Pinഀ Unbraced Length ftഀ 3.00 4.00ഀ Loadsഀ -ഀ Live Load Used This Span ?ഀ I Yes Yesഀ Dead Load k/ftഀ I 0.180 0.180ഀ Live Load k/ftഀ 0.600 0.600ഀ Point #1 DL k Iഀ 0.980ഀ LL kഀ 2.490ഀ @ X ftഀ 12.000ഀ Hesultsഀ MISMSEMMഀ Mmax @ Cntrഀ k-ftഀ @X=ഀ ftഀ Max @ Left Endഀ k-ftഀ Max @ Right Endഀ k-ftഀ fb : Actualഀ psiഀ Fb : Allowableഀ psiഀ fv : Actualഀ psiഀ Fv : Allowableഀ psiഀ 0.00ഀ 30.90ഀ 0.00ഀ 9.39ഀ 0.00ഀ -3.51ഀ -3.51ഀ 0.00ഀ 1,815.1ഀ 15, 980.1ഀ 33, 000.0ഀ 33, 000.0ഀ Bending OKഀ Bending OKഀ 958.7ഀ 3,532.9ഀ 20,000.0ഀ 20,000.0ഀ I-_ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 7.33ഀ Shear @ Rightഀ kഀ 2.34ഀ 8.62ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 2ഀ 28ഀ LL @ Leftഀ k~ഀ 0.00ഀ .ഀ 7.39ഀ Total @ Leftഀ kഀ 0.00ഀ 9.67ഀ DL @ Rightഀ kഀ 2.28ഀ 2.12ഀ LL @ Rightഀ k iഀ 7.39ഀ 6.50ഀ Total @ Rightഀ k !ഀ 9.67ഀ 8.62ഀ Max. Deflectionഀ in Iഀ 0.223ഀ -0.411ഀ @ X =ഀ ftഀ 0.00ഀ 8.32ഀ Span/Deflection Ratioഀ iഀ 323.6ഀ 466.9ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ R 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Shearഀ k Iഀ 0.00ഀ 7.33ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Momentഀ k-ftഀ 0.00ഀ 3.51ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Max. Deflectionഀ in jഀ 0.2225ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Denver, CO 80202 Description : Lodge Expansionഀ i - 303.623.4927ഀ Scope:ഀ Fax: 303.623.6602ഀ Rev: 580007ഀ user: KW-0606238,Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB28ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ Page 1ഀ 5500.ecw:Roof Beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Description Cant Spanഀ Span ft 3.00 16.00ഀ Steel Section w12X19 w12X19ഀ End Fixity Free-Pin Pin-Pinഀ Unbraced Length ft 3.00 4.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yes Yesഀ Dead Loadഀ k/ftഀ 0.090 0.090ഀ Live Loadഀ k/ftഀ 0.300 0.300ഀ Point #1 DLഀ k Iഀ 4.070ഀ LLഀ kഀ 6.710ഀ @ Xഀ ftഀ 12.000ഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ k-ftഀ 0.00ഀ ftഀ 'ഀ 0.00ഀ k-ftഀ 0.00ഀ k-ftഀ -1.75ഀ psiഀ 985.0ഀ psiഀ 33,000.0ഀ Bending OKഀ psiഀ 409.4ഀ psi 20,000.0ഀ 41.19ഀ 11.95ഀ -1.75ഀ 0.00ഀ 23,119.5ഀ 29,568.6ഀ Bending OKഀ 3,882.7ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 5.92ഀ Shear @ Rightഀ kഀ 1.17ഀ 11.10ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 2.03ഀ LL @ Leftഀ k~ഀ 0.00ഀ 5.06ഀ Total @ Leftഀ kഀ 0.00ഀ 7.09ഀ DL @ Rightഀ kഀ 2.03ഀ 3.75ഀ LL @ Rightഀ k Iഀ 5.06ഀ 7.35ഀ Total @ Rightഀ k Iഀ 7.09ഀ 11.10ഀ Max. Deflectionഀ in lഀ 0.224ഀ -0.433ഀ @ X =ഀ ft iഀ 0.00ഀ 8.64ഀ Span/Deflection Ratioഀ 321.8ഀ 443.4ഀ Query Valuesഀ iഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ Shearഀ k:ഀ 0.00ഀ 5.92ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -1.75ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.2238ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000 0.0000ഀ 0.0000ഀ ' Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ tഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ L 303.623.4927ഀ Scopeഀ ' Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ 5500.ecw:Roof Beamsഀ Iഀ Description Roof Beam - RB29ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 .ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Left Span Right Spanഀ Span ftഀ 7.00 7.00ഀ Steel Sectionഀ wsxlo wsxloഀ End Fixityഀ Pin-Pin Pin-Pinഀ Unbraced Length ftഀ 0.50 0.50ഀ Loadsഀ Live Load Used This Span ? Yes Yesഀ Dead Load k/ft 0.120 0.120ഀ Live Load k/ft 0.400 0.400ഀ Resultsഀ k-ftഀ 1.79ഀ 1,79ഀ ftഀ 2.61ഀ 4.39ഀ k-ftഀ 0.00ഀ -3.18ഀ k-ftഀ '-3.18ഀ 0.00ഀ psiഀ 4,895.4ഀ 4,895.4ഀ psiഀ 30,000.0ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ psiഀ 1,696.1ഀ 1,696.1ഀ psiഀ ; 20,000.0ഀ 20,000.0ഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 1.36ഀ 2.27ഀ Shear @ Rightഀ kഀ 2.27ഀ 1.36ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.31ഀ 1.05ഀ LL @ Leftഀ kഀ 1.05ഀ 3.50ഀ Total @ Leftഀ kഀ 1.36ഀ 4.55ഀ DL @ Rightഀ k iഀ 1.05ഀ 0.31ഀ LL @ Rightഀ kഀ 3.50ഀ 1.05ഀ Total @ Rightഀ kഀ 4.55ഀ 1.36ഀ Max. Deflectionഀ in Iഀ -0.013ഀ -0.013ഀ @ X =ഀ ft'ഀ 2.94ഀ 4.06ഀ Span/Deflection Ratioഀ 6,422.1ഀ 6,422.1ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 1.36ഀ 2.27ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -3.18ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in[ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Ds9nr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scope:ഀ > f' Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500-erwRnof Beamsഀ Description Roof Beam - RB30ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1ഀ 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Steel Sectionഀ End Fixityഀ Unbraced Lengthഀ Left Cantഀ ft 2.00ഀ wsxlaഀ Free-Pinഀ ft 2.00ഀ Spanഀ 6.00ഀ waxlaഀ Pin-Pinഀ 6.00ഀ Right Cantഀ 1.00ഀ wsxloഀ Pin-Freeഀ 1.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Iഀ Yes Yesഀ Dead Load k/ftഀ 0.150ഀ 0.150 0.150ഀ Live Load k/ftഀ 0.500ഀ 0.500 0.500ഀ Point #1 DL kഀ 0.300ഀ 0.300ഀ LL kഀ 1.000ഀ 1.000ഀ @ X ftഀ 1.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ jഀ 0.00ഀ 0.27ഀ 0.00ഀ @ X =ഀ ftഀ 'ഀ 0.00ഀ 3.60ഀ 1.00ഀ Max @ Left Endഀ k-ftഀ lഀ 0.00ഀ -3.90ഀ -1.62ഀ Max @ Right Endഀ k-ftഀ -3.90ഀ -1.62ഀ O.OGഀ fb : Actualഀ psiഀ 5,994.2ഀ 5,994.2ഀ 2,497.6ഀ Fb : Allowableഀ psiഀ 30,000.0ഀ 24,690.8ഀ 30,000.0ഀ fഀ Aഀ tഀ lഀ Bending OKഀ Bending OKഀ Bending OKഀ v :ഀ cഀ uaഀ psiഀ 1,938.4ഀ 1,736.5ഀ 1,453.8ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 2.33ഀ 1.95ഀ Wഀ Shear @ Rightഀ kഀ 2.60ഀ 1.57ഀ 1.30ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 1.14ഀ 0.81ഀ LL @ Leftഀ kഀ 0.00ഀ 3.79ഀ 2.71ഀ Total @ Leftഀ kഀ 0.00ഀ 4.93ഀ 3.52ഀ DL @ Rightഀ kഀ 1.14ഀ 0.81ഀ 0.00ഀ LL @ Rightഀ kഀ 3.79ഀ 2.71ഀ 0.00ഀ Total @ Rightഀ kഀ 4.93ഀ 3.52ഀ 0.00ഀ Max. Deflectionഀ in!ഀ -0.023ഀ 0.004ഀ -0.004ഀ @ X =ഀ ft Iഀ 0.00ഀ 1.48ഀ 1.00ഀ Span/Deflection Ratioഀ 1ഀ 2,083.1ഀ 17,321.4ഀ 6,827.8ഀ Query Valuesഀ aഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 2.33ഀ 1.95ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 00ഀ 0ഀ 0ഀ 00ഀ Momentഀ k-ftഀ 0.00ഀ -3.90ഀ -1.62ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ Max. Deflectionഀ in jഀ -0.0230ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ ~`ttഀ !ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ k""ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ ,ഀ 303.623.4927ഀ Scope:ഀ Yഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Page 1ഀ SSOO.ecw:Roof Beamsഀ Description Roof Beam - RB31ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Spanഀ Iഀ Span ft 2.00ഀ 6.50ഀ Steel Sectionഀ WlOX12ഀ WlOX12ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Length ftഀ I 2.00ഀ 3.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ i 0.230ഀ 0.230ഀ Live Load k/ftഀ 0.200ഀ 0.200ഀ Point #1 DL kഀ 1.150ഀ 0.810ഀ LL kഀ I 1.000ഀ 2.710ഀ @ X ftഀ 6.000ഀ Point #2 DL kഀ 1.140ഀ LL kഀ 3.790ഀ @ X ftഀ ! 1.500ഀ Resultsഀ _ഀ Mmax @ Cntr k-ftഀ @ X = ftഀ ! 0.00ഀ 0.00ഀ 1.68ഀ 5.98ഀ Max @ Left End k-ftഀ ! 0.00ഀ -7.62ഀ Max @ Right End k-ftഀ -7.62ഀ 0.00ഀ fb : Actual psiഀ 8,393.0ഀ 8,393.0ഀ Fb : Allowable psiഀ 30,000.0ഀ 30,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 4,234.0ഀ 1,852.3ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.00ഀ 2.84ഀ Shear @ Right kഀ 7.94ഀ 3.47ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 4.07ഀ LL @ Left kഀ 0.00ഀ 1ഀ 6.71ഀ Total @ Left kഀ 0.00ഀ 10.78ഀ DL @ Right kഀ 4.07ഀ 0.98ഀ LL @ Right kഀ 1ഀ 6.71ഀ 2.49ഀ Total @ Right kഀ 10.78ഀ 3.47ഀ Max. Deflection inഀ -0.030ഀ 0.009ഀ @ X = ftഀ 0.00ഀ 1.86ഀ Span/Deflection Ratioഀ 1,593.3ഀ 9,152.4ഀ Query Valuesഀ Location ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ Shear k Iഀ 0.00ഀ 2.84ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ Moment k-ftഀ 0.00ഀ -7.62ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ Max. Deflection inഀ -0.0301ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ 1?~_- zaഀ Monroe & Newell Engineers, Inc.ഀ rഀ Title : Vail's Front Door - Spaഀ Dഀ Aഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ sgnr:ഀ rthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ ' y Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Desiഀ nഀ Page 1ഀ (c)1983.2003 ENERCALC Engineerino Softwareഀ gഀ 5500.ecw:Roof Beams ;ഀ Description Roof Beam - RB33ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W1 2X30ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 15.50 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 6.50 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ DL 0.460ഀ k/ftഀ LL 0.400ഀ k/ftഀ STഀ k/ftഀ Start Location 6.500ഀ ftഀ End Location 15.500ഀ ftഀ Point Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #y6~ #7ഀ Dead Load 1.760ഀ 3.750ഀ kഀ Live Load 5.850ഀ 7.350ഀ kഀ Short Termഀ kഀ Location 6.500ഀ 9.000ഀ ftഀ summaryഀ Using: W 12X30 section, Span =ഀ 15.50ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 6.50ft, LDF = 1.000ഀ Actual Allowableഀ Momentഀ 81.031 k-ft 96.500 k-ftഀ fb : Bending Stressഀ 25.191 ksi 30.000 ksiഀ fb / Fbഀ 0.840 : 1ഀ Shear 15.361 k 64.168 kഀ fv : Shear Stress 4.788 ksi 20.000 ksiഀ fv / Fv 0.239 : 1ഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.457 inഀ Length/DL Deft 1,139.8 :1ഀ Length/(DL+LL Defl) 406.7 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+ST LLഀ LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cantsഀ @ Cantsഀ Max. M +ഀ 81.03 k-ftഀ 29.20ഀ 81.03ഀ k-ftഀ Max. M -ഀ -0.00ഀ -0.00ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Leftഀ 11.55 kഀ 4.03ഀ 11.55ഀ kഀ Shear @ Rightഀ 15.36 kഀ 6.08ഀ 15.36ഀ kഀ Center Defl. -0.457 in -0.163ഀ -0.457ഀ -0.457ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000in 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 in 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ft 0.000ഀ 0.000 -ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 11.55 4.03ഀ 11.55ഀ 11.55ഀ kഀ Reaction @ Rt 15.36 6.08ഀ 15.36ഀ 15.36ഀ kഀ Fa calc'd per Eq. E2-1, K*Ur < Ccഀ I Beam, Major Axis, UrT < (102,000 * Cb / Fy)^.5, Fb = 0.6 Fy (F3)ഀ I Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / 0 * d)ഀ 264aഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Ds9nr: Arthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ tഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ Steel Beam Desiഀ nഀ Page 2ഀ (0 983-2003 ENERCALC Eഀ sഀ naineerino Softwareഀ gഀ SSOO.ecw:Roof Beamsഀ Descriptionഀ Roof Beam - RB33ഀ Section Propertiesഀ W1 2X30ഀ Depthഀ 12.340 inഀ Weightഀ 29.86 #/ftഀ Web Thickഀ 0.260 inഀ Ixxഀ 238.000 in4ഀ Widthഀ 6.520 inഀ lyyഀ 20.300 in4ഀ Flange Thickഀ 0.440 inഀ Sxxഀ 38.600 in3ഀ Areaഀ 8.79 in2ഀ Syyഀ 6.240 in3ഀ Rtഀ 1.730 inഀ R-xxഀ 5.210 inഀ Values for LRFD Design....ഀ R-yyഀ 1.520 inഀ Jഀ 0.460 in4ഀ Zxഀ 43.100 in3ഀ Cwഀ 719.00 in6ഀ Zyഀ 9.560 in3ഀ Kഀ 0.740 inഀ F 1ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ r1 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ L 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB34ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksഀ Load Duration Factor 1.00ഀ Spans Considered Contiഀ nuous Over Suppoഀ rtsഀ Span Informationഀ Descriptionഀ Cantഀ Span W.ഀ Span ftഀ 3.00ഀ 16.00ഀ Steel Sectionഀ w12X19ഀ w12X19ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Length ftഀ 3.00ഀ 4.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.240ഀ 0.240ഀ Live Load k/ftഀ 0.800ഀ 0.800ഀ Resultsഀ _"q Wഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 30.98ഀ @ X =ഀ ftഀ 0.00ഀ 8.32ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -4.68ഀ Max @ Right Endഀ k-ftഀ iഀ -4.68ഀ 0.00ഀ fb : Actualഀ psiഀ 2,626.6ഀ 17,387.1ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 29,568.6ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 1,091.8ഀ 3,013.9ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ iഀ - - -ഀ Shear @ Left kഀ 0.00ഀ 8.61ഀ Shear @ Right kഀ 3.12ഀ 8.03ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 2.71ഀ LL @ Left kഀ 0.00ഀ 9.02ഀ Total @ Left kഀ 0.00ഀ 11.73ഀ DL @ Right kഀ 2.71ഀ 1.85ഀ LL @ Right kഀ 9.02ഀ 6.17ഀ Total @ Right kഀ 11.73ഀ 8.03ഀ Max. Deflection in iഀ 0.205ഀ -0.372ഀ @X= ftഀ 0.00ഀ 8.11ഀ Span/Deflection Ratio Iഀ 350.9ഀ 515.4ഀ Locationഀ ft lഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 8.61ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k ftഀ 0.00ഀ -4.68ഀ 0.00ഀ 0.00ഀ 0.00ഀ ax. Deflectionഀ n iഀ .2052ഀ .0000ഀ .0000ഀ .0000ഀ 0.00 0.00 0.00ഀ 0.00 0.00 0.00ഀ 0.00 0.00 0.00ഀ 0.0000 0.0000 0.0000 0.0000ഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ R- eannnaഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ User. KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 1ഀ ! (c)7983-2003 ENERCALC Engineering Software 5500.ecw:Roof Beamsഀ Description Roof Beam - RB35ഀ General Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W12X14 Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Span 6.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 It LL & ST Act Togetherഀ R;ഀ fight Cantഀ Lu : Unbraced Lengthഀ 0.00 ftഀ 6.00 ftഀ Point Loadsഀ #1ഀ Dead Load 2.710ഀ #2 #3ഀ #4ഀ Live Load 9.020ഀ Short Termഀ Location 3.000ഀ Summaryഀ Using: W12X14 section, Span=ഀ 6.00ft, Fy = 50.oksiഀ End Fixity = Pinned-Pinned, Luഀ = 6.00ft, OF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 17.659 k-ftഀ 29.735 k-ftഀ fb : Bending Stressഀ 14.222 ksiഀ 23.948 ksiഀ fb / Fbഀ 0.594 :1ഀ Shearഀ 5.907 kഀ 47.640 kഀ fv : Shear Stressഀ 2.480 ksiഀ 20.000 ksiഀ fv / Fvഀ 0.124 :1ഀ #5ഀ Note! Short Term Loads Are WIND Loads.ഀ #6 #7ഀ kഀ kഀ kഀ ftഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.036 inഀ Length/DL Defl 8,610.6: 1ഀ Length/(DL+LL Defl) 2,019.1: 1ഀ r-orce & Stress Summar,ഀ Maximumഀ Max. M +ഀ 17.66,k-ftഀ Max. M -ഀ Max. M @ Leftഀ Max. M @ Rightഀ Shear @ Leftഀ 5.91 kഀ Shear @ Rightഀ 5.91 kഀ Center Defl.ഀ -0.036 inഀ Left Cant DOഀ 0.000inഀ Right Cant Deflഀ 0.000 inഀ ...Query Defl @ഀ 0.000 ftഀ Reaction @ Leftഀ 5.91ഀ Reaction @ Rtഀ 5.91ഀ Fa calc'd per Eq. E2-2, K*L/r > Ccഀ I Beam, Major Axis, (102,000 * Cb / Fyഀ Section Propertiesഀ W12X14ഀ Depthഀ 11.910 inഀ Web Thickഀ 0.200 inഀ Widthഀ 3.970 inഀ Flange Thickഀ 0.225 inഀ Areaഀ 4.16 in2ഀ Rtഀ 0.950 inഀ Values for LRFD Design....ഀ Jഀ 0.070 in4ഀ Cwഀ 80.60 in6ഀ Theseഀ columns are Dead + Live Loadഀ placed as noted »ഀ DLഀ LLഀ LL+STഀ LLഀ LL+STഀ Onlyഀ @ Centerഀ @ Centerഀ @ Cantsഀ @ Cantsഀ 4.13ഀ 17.66ഀ k-ftഀ k-ftഀ k-ftഀ k-ftഀ 1.40ഀ 5.91ഀ kഀ 1.40ഀ 5.91ഀ kഀ -0.008ഀ -0.036ഀ -0.036ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 1.40ഀ 5.91ഀ 5.91ഀ kഀ 1.40ഀ 5.91ഀ 5.91ഀ kഀ L/rT (510,000 * Cb / Fy)A.5 , Fb per Eq. F1-6ഀ Weightഀ 14.13 #/ftഀ Ixxഀ 88.600 in4ഀ lyyഀ 2.360 in4ഀ Sxxഀ 14.900 in3ഀ SYyഀ 1.190 in3ഀ R-xxഀ 4.620 inഀ R-yyഀ 0.753 inഀ Zxഀ 17.400 in3ഀ Zyഀ 1.900 in3ഀ Kഀ 0.525 inഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ f Fax: 303.623.6602ഀ Rev: 580006ഀ User: Kw-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Desiഀ nഀ Page 1ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ gഀ SSOO.ecw:Roof Beamsഀ Description Roof Beam - RB36ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W12X19ഀ Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Spanഀ 7.00 ftഀ Bm Wt. Added to Loads Elastic Modulus 29,000.Oksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 7.00 ftഀ Point Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ Dead Load 4ഀ 090ഀ #2ഀ #3 #4 #5 #6 #7ഀ .ഀ Live Load 13.620ഀ kഀ kഀ Short Termഀ kഀ Location 3.500ഀ ftഀ rഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.058 inഀ Length/DL Defl 6,146.2 :1ഀ Length/(DL+LL Defl) 1,441.4 :1ഀ Shear 8.921 k 57.152 kഀ fv : Shear Stress 3.122 ksi 20.000 ksiഀ fv / Fv 0.156 :1ഀ Using: W 12X19 section, Span= 7.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 7.00ft, LDF = 1.000ഀ Actual Allowableഀ Momentഀ 31.108 k-ft 38.702 k-ftഀ fb :Bending Stressഀ 17.526 ksi 21.804 ksiഀ fb / Fbഀ 0.804 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+ST LL LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cants @ Cantsഀ Max. M + 31.11 k-ftഀ 7.27ഀ 31.11 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 8.92 kഀ 2,11ഀ 8.92 kഀ Shear @ Right 8.92 kഀ 2,11ഀ 8.92 kഀ Center Defl.ഀ -0.058 inഀ -0.014ഀ -0.058ഀ -0.058ഀ 0.000ഀ 0.000 inഀ Left Cant Deflഀ 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Leftഀ 8.92ഀ 2.11ഀ 8.92ഀ 8.92ഀ kഀ Reaction @ Rtഀ 8.92ഀ 2.11ഀ 8.92ഀ 8.92ഀ kഀ Fa calc'd per Eq. E2-2, K'Ur > Ccഀ I Beam, Major Axis, (102,000' Cb / Fy)A.5ഀ UrT (510,000 Cb / Fy)A.5, Fb per Eq. F1-6ഀ n Propertiesഀ ~ഀ W2X19ഀ Depthഀ 12.160 inഀ Weightഀ 18.92 #/ftഀ Web Thickഀ 0.235 inഀ Ixxഀ 130.000 in4ഀ Widthഀ 4.005 inഀ lyyഀ 3.760 in4ഀ Flange Thickഀ 0.350 inഀ Sxxഀ 21.300 in3ഀ Areaഀ 5.57 in2ഀ Syyഀ 1.880 in3ഀ Rtഀ 1.000 inഀ R-xxഀ 4.820 inഀ Values for LRFD Design....ഀ R-yyഀ 0.822 inഀ Jഀ 0.180 in4ഀ Zxഀ 24.700 in3ഀ Cwഀ 131.00 in6ഀ Zyഀ 2.980 in3ഀ Kഀ 0.650 inഀ . Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ q Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, ver 5-B.o, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering software Description Roof Beam - RB37ഀ ~ General Informationഀ Steel Section : W12X19ഀ Center Span 15.00 ftഀ Left Cant. 0.00 ftഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 4.00 ftഀ Distributed Loadsഀ #1 #2ഀ DL 0.288ഀ LL 0.200ഀ STഀ Start Locationഀ End Location 15.000ഀ ഀ Job # 5500.02ഀ Date: 10:32AM, 14 DEC 05ഀ Page 1ഀ :Roof Beamsഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy 50.00 ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ LL & ST Act Togetherഀ Point Loadsഀ #1ഀ Dead Loadഀ 1.850ഀ Live Loadഀ 6.170ഀ Short Termഀ Locationഀ 7.000ഀ #2ഀ Note! Short Term Loads Are WIND Loads.ഀ #4 #5 #6 #7ഀ kഀ kഀ kഀ ftഀ Summaryഀ Using: W 12X19 section, Spanഀ = 15.00ft, Fy = 50.Oksiഀ End Fixity = Pinned Pinned, Lഀ u = 4.00ft, LDF = 1.000ഀ Actualഀ Momentഀ 44.065 k-ftഀ fb : Bending Stressഀ 24.825 ksiഀ fb / Fbഀ 0.840 : 1ഀ Shearഀ 8.079 kഀ fv : Shear Stressഀ 2.827 ksiഀ fv / Fvഀ 0.141 : 1ഀ Beam OKഀ Static Load Case Governs Stressഀ Allowableഀ 52.484 k-ftഀ Max. Deflection -0.410 inഀ 29.569 ksiഀ Length/DL Defl 1,184.4 :1ഀ Length/(DL+LL Defl) 439.0 :1ഀ 57.152 kഀ 20.000 ksiഀ Force & Stress Summaryഀ « These columns are Deadഀ + Live Load placed as noted »ഀ DLഀ LLഀ LL+STഀ LLഀ LL+STഀ Maximumഀ Onlyഀ @ Centerഀ @ Centerഀ @ Cantsഀ @ Cantsഀ Max. M + 44.07 k-ftഀ 15.49ഀ 44.07ഀ k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 8.08 kഀ 3.29ഀ 8.08ഀ kഀ Shear @ Right 7.54 kഀ 3.17ഀ 7.54ഀ kഀ Center Defl. -0.410 inഀ -0.152ഀ -0.410ഀ -0.410ഀ 0.000ഀ 0ഀ 000 inഀ Left Cant Defl 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ .ഀ 0ഀ 000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ .ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 8.08ഀ 3.29ഀ 8.08ഀ 8.08ഀ kഀ Reaction @ Rt 7.54ഀ 3.17ഀ 7.54ഀ 7.54ഀ kഀ Fa calc'd per Eq. E2-2, K'L/r > Ccഀ I Beam, Major Axis, (102,000' Cb / Fy)A.5 UrT (510,000' Cb / Fy)A.5ഀ , Fb per Eq. F1-6ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description :Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ve, -Dec-2003ഀ o Software Steel Beam Design Page 2ഀ (c)79833--2 2003 3 ENE ENERCALC LC En Engineering SSOO.ecw:Roof Beamsഀ ZMEMEMEMMEMഀ Description Roof Beam RB37ഀ Section Propertiesഀ W12X19ഀ Depthഀ 12.160 inഀ Weightഀ 18.92 #/ftഀ Web Thickഀ 0.235 inഀ Ixxഀ 130.000 in4ഀ Widthഀ 4.005 inഀ lyyഀ 3.760 in4ഀ Flange Thickഀ 0.350 inഀ Sxxഀ 21.300 in3ഀ Areaഀ 5.57 in2ഀ Syyഀ 1.880 1n3ഀ Rtഀ 1.000 inഀ R-xxഀ 4.820 inഀ Values for LRFD Design....ഀ R-yyഀ 0.822 inഀ Jഀ 0.180 in4ഀ Zxഀ 24.700 in3ഀ Cwഀ 131.00 in6ഀ Zyഀ 2.980 in3ഀ Kഀ 0.650 inഀ Monroe & Neഀ well Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PE Dateഀ : 10:32AM, 14 DEC 05ഀ Denver, CO 8ഀ 0202ഀ Description : Lodge Expansionഀ _ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983.2003 ENERCALC Eഀ Multi-Span Steel Beamഀ Page 1ഀ ngineering Softwareഀ 5500 ecwRCOf Beamsഀ Description Roofഀ Beam RB38ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supഀ portsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Span ft 8.50ഀ 7.50ഀ Steel Sectionഀ w8x15ഀ w8x15ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 0.50ഀ 3.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load Witഀ 0.120ഀ 0.120•ഀ Live Load k/ftഀ 0.400ഀ 0.400ഀ Resultsഀ Mmax @ Cntr k-ftഀ 0.23ഀ 0.00ഀ OQ X = ftഀ 0.96ഀ 0.00ഀ Max @ Left End k-ftഀ l 0.00ഀ -14.62ഀ Max @ Right End k-ftഀ i -14.62ഀ 0.00 'ഀ fb : Actual psiഀ ' 14,826.1ഀ 14,826.1ഀ Fb : Allowable psiഀ 33,000.0ഀ 33,000.0ഀ fv : Actualഀ Bending CKഀ Bending CKഀ psiഀ 1,978.2ഀ 1,962.8ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.49 1ഀ 3.90ഀ Shear @ Right kഀ 3.93ഀ 0.00ഀ Reactions...ഀ DL @ Left kഀ 0.11ഀ 1.81ഀ LL @ Left kഀ 0.38ഀ 6.02ഀ Total @ Left kഀ 0.49ഀ 7.83ഀ DL @ Right kഀ 1.81ഀ 0.00ഀ LL @ Right kഀ 6.02ഀ 0.00ഀ Total @ Right kഀ 7.83ഀ 0.00ഀ Max. Deflection inഀ 0.043ഀ -0.518ഀ @ X = ft lഀ 5.55ഀ 7.50ഀ Span/Deflection Ratio Iഀ 2,379.5ഀ 347.3ഀ i Query Valuesഀ Location ftഀ 0.00ഀ 0.00 0.00ഀ 0.00 0.00 0.00ഀ R 0ഀ 00 0ഀ 00ഀ Shear kഀ 0.49ഀ 3.90 0.00ഀ 0.00 0.00 0.00ഀ .ഀ .ഀ 0.00 0ഀ 00ഀ Moment k-ftഀ 0.00ഀ -14.62 0.00ഀ 0.00 0.00 0.00ഀ .ഀ 0ഀ 00 0ഀ 00ഀ Max. Deflection inഀ 0.0000ഀ 0.0000 0.0000ഀ 0.0000 0.0000 0.0000ഀ .ഀ .ഀ 0.0000 0.0000ഀ r;ഀ iഀ 1ഀ User: KW-0606238, Ver 5.ഀ (c)1983-2003 ENERCALCഀ Descriptionഀ fS4'ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:32AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Fax: 303.623.6602 Scope:ഀ Aware Multi-Span Steel Beam Page 1ഀ Roof Beam - RB39ഀ 5500.ecw:Roof Beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ FY - Yield Stress 50.00 ksi Load Duration Factorഀ 1.00ഀ Sഀ pans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Iഀ Span ftഀ cantഀ Steel Sectionഀ 16.00ഀ 3.00ഀ End Fixityഀ WlOX30ഀ wlOX30ഀ Iഀ Unbraced Length ftഀ Pin-Pinഀ Pin-Freeഀ 4.00•ഀ 3.00ഀ Loadsഀ Live Load Used This Span ?ഀ Iഀ Dead d k/ftഀ Yesഀ 0ഀ 360ഀ Yesഀ -ഀ Iഀ Live Load k/ftഀ .ഀ .ഀ 1.200ഀ 0.360ഀ 1.200ഀ Resultsഀ Mmax @ Cntr k-ftiഀ 46.47ഀ 0ഀ 00ഀ @ X - ftlഀ 7.68ഀ .ഀ 0ഀ 00ഀ Mഀ Max @ Left End k-ftഀ 0.00ഀ .ഀ -7ഀ 02ഀ Max @ Right End k-ftഀ -7.02ഀ .ഀ 0.00ഀ fb : Actual psi Iഀ 17,172.2ഀ 2ഀ 594ഀ 1ഀ Fb : Allowable psiഀ 33,000.0ഀ ,ഀ .ഀ 33,000.0ഀ fv :Actualഀ Bending OKഀ Bending OKഀ Psiഀ Fv : Allowableഀ 4,112.9ഀ 1,490.0ഀ psiഀ 20,000.0ഀ 20,000.0ഀ ions & Deflectionsഀ @ Left kഀ tഀ 12.04ഀ 4 B8ഀ @ Right kഀ 12.92ഀ 0ഀ 00ഀ ons...ഀ .ഀ DL @ Left k lഀ LL @ Leftഀ 2.78ഀ 4.06ഀ kഀ Total @ Left kഀ 9.26ഀ 12ഀ 04ഀ 13.54ഀ DL @ Right kഀ .ഀ 17.60ഀ LL @ Right kഀ 4.06ഀ 0.00ഀ Total @ Right kഀ 13.54ഀ 17ഀ 60ഀ 0.00ഀ Max. Deflection iഀ .ഀ 0.00ഀ nഀ @ X = ftഀ -0.427ഀ 0.235ഀ Span/Deflection Ratioഀ 7.89ഀ 3.00ഀ 449.4ഀ 305.9ഀ Query Valuesഀ Location ftഀ Shear kഀ 0.00ഀ 12.04ഀ 0.00ഀ 4ഀ 68ഀ -ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ r -ഀ 0ഀ 00ഀ Moment k-ftഀ Max. Deflectionഀ iഀ Iഀ -0.00ഀ .ഀ -7.02ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0.00ഀ .ഀ 0.00ഀ 0.00ഀ 0.00ഀ nഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.00ഀ 00ഀ 0.00ഀ 0ഀ 0000ഀ 0.00ഀ 0.00ഀ .ഀ 0.0000ഀ 0.0000ഀ 2g1c3Zഀ _ rrഀ Mഀ `Q rഀ v rഀ ~ ~a 2~JO t ~~~ta ~.s•ഀ ~ ~ 9~~%~ ~ ~ ~ ~ . ~ ~ ~ t rte,ഀ i 4 r ---ys -Fഀ F ~ a~g ~ GP ~ ~ ~.7 ~ i 1 ~ ti,.f € PA r,~aഀ 17ഀ ~~i9~'.~tw.`~~~v fed j g ~ ~ ~Caj .a ~ഀ cei 41,ഀ Ilkഀ I ,GJ lftY2Zt-t V oഀ ! Jഀ notഀ i X318 f--ഀ Ileഀ ~rT P rf l gip lr { lZ.e tiz . s It •'i 'Pഀ O.ഀ FYI"ഀ P~Jr~~ Jt`L 2 Ail c 1! Fell* °ഀ ഀ rഀ mഀ fഀ IZ(3 I o3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ i 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238,ver 5.8.0, 1-Dec-2003 Multi all Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 1ഀ 5500 ecw8195 Beamsഀ Description Roof Beam - RB101ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC 2003 NFPA 5000ഀ Fy Yield Stress 50.00 ksl Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ r) ' t'ഀ v Ionഀ Left Cantഀ Spanഀ Spanഀ ftഀ 3.00ഀ 4.00ഀ Steel Sectionഀ waxioഀ waxioഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.00ഀ 4.00ഀ Loadsഀ Live Load Used This Span ?zI Yesഀ Dead Load k/ft 0.150ഀ Live Load k/ft 0.500ഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ Yesഀ 0.150ഀ 0.500ഀ k-ftഀ 0.00ഀ -ഀ 0.25 uഀ ftഀ 0.00ഀ 3.12ഀ k-ftഀ k-ftഀ 0.00ഀ -2.92ഀ -2.92ഀ 0.00ഀ psiഀ 41495.8ഀ 4,495.8ഀ psiiഀ 30,000.0ഀ 29,492.2ഀ Bending OKഀ Bending OKഀ psiഀ 1,453.8ഀ 1,514.4ഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 2.03ഀ Shear @ Right kഀ 1.95ഀ 0.57ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 0.92ഀ LL @ Left kഀ 0.00ഀ 3.06ഀ Total @ Left kഀ 0.00ഀ 3.98ഀ DL @ Right kഀ 0.92ഀ 0.13ഀ LL @ Right kഀ 3.06ഀ 0.44ഀ Total @ Right kഀ 3.98ഀ 0.57ഀ Max. Deflection inഀ -0.025ഀ 0.002ഀ @ X = ftഀ 0.00ഀ 1.12ഀ Span/Deflection Ratioഀ 2,853.2ഀ 24,200.3ഀ Query Valuesഀ Location Iഀ ftഀ Shearഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ -ഀ 0.00ഀ -ഀ 0.00ഀ 0ഀ 00ഀ kഀ Moment k-ftഀ 0.00ഀ 0.00ഀ 2.03ഀ -2ഀ 92ഀ 0.00ഀ 0ഀ 00ഀ 0.00ഀ 0ഀ 00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ Max. Deflection in Iഀ -0.0252ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0ഀ 0000ഀ 0.00ഀ 0ഀ 0000ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ I~)ഀ Rev: 580007ഀ User: KW-0606,ഀ (0)1983.2003 Etഀ -----r_.ഀ 5.8.0, 1-Dec-2003ഀ C Engineering Softwareഀ Roof Beam - RB102ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ General Information Code Ref: AISC 9th ASD 1997 UBC 2003 IBC 2003 NFPA 5000ഀ Fy Yield Stress 50 00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ rticn, uu~rrnailOnഀ Descriptionഀ Spanഀ Steel Sectionഀ End Fixityഀ Unbraced Lengthഀ Dead Loadഀ Live Loadഀ Thisഀ Len cantഀ Spanഀ ftഀ 1.00ഀ 4.00ഀ wsx10ഀ wsxioഀ ftഀ Free-Pinഀ 1.00ഀ Pin-Pinഀ 4.00ഀ vഀ Yesഀ Yesഀ k/ftഀ 0.150ഀ 0.150ഀ kJftഀ 0.500ഀ 0.500ഀ ncauR.7ഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 1.14ഀ @ X =ഀ ftഀ 0.00ഀ 2.13ഀ Max @ Left Endഀ k-ftഀ . 0.00ഀ -0ഀ 32ഀ Max @ Right Endഀ k-ftഀ j -0.32ഀ .ഀ 0.00ഀ fb : Actualഀ psiiഀ 499.5ഀ 1,756.1ഀ Fb : Allowableഀ psiഀ 30;000.0ഀ 29,492.2ഀ fv : Actualഀ Bending OKഀ Bending OKഀ Fv : Allowableഀ psiഀ psiഀ 484.6ഀ 20,000.0ഀ 1,029.8ഀ 20,000.0ഀ Heactions & Deflectionsഀ Shear @ Leftഀ kഀ Shear @ Rightഀ kഀ Reactions...ഀ DL @ Leftഀ kഀ LL @ Leftഀ kഀ Total @ Leftഀ kഀ DL @ Rightഀ kഀ LL @ Rightഀ kഀ Total @ Rightഀ k Iഀ Max. Deflectionഀ @ X=ഀ inഀ ftഀ Span/Deflection Ratioഀ ,ഀ 0.00ഀ 1.38ഀ 0.65ഀ 1,22ഀ 0.00ഀ 0.47ഀ 0.00ഀ 1.56ഀ 0.00ഀ 2.03ഀ 0.47ഀ 0.28ഀ 1.56ഀ 0.94ഀ 2.03ഀ 1.22ഀ 0.002ഀ -0.004ഀ 0.00ഀ 2.05ഀ 10,123.8ഀ 13,463.9ഀ query valuesഀ Locationഀ Shearഀ ftഀ 0 00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Momentഀ kഀ k-ftഀ 0.00ഀ 0ഀ 00ഀ 1.38ഀ -0ഀ 32ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ Max. Deflectionഀ inഀ .ഀ 0.0024ഀ .ഀ 0.0000ഀ 0.00ഀ 0ഀ 0000ഀ 0.00ഀ 0ഀ 0000ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.ഀ 00ഀ .ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 2f~i~4-ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Fax: 303.623.6602 Scopeഀ Multi-Span Steel Beamഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ / 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ Lഀ 303.623.4927ഀ Scopeഀ s 4' Fax: 303.623.6602ഀ Rev: 580006ഀ User: 03 EERCA -Dec-2003ഀ (c)11983-2 9834003 ENERCALC Engineering g Softwareഀ Steel Beam Design Page 1ഀ 5500.ecw:8195 Beamsഀ Description Roof Beam - RB103 Y Tഀ Center Spanഀ Left Cant.ഀ Right Cantഀ Lu : Unbraced Lengthഀ Pinned-Pinnedഀ Bm Wt. Added to Loadsഀ LL & ST Act Togetherഀ Load Duration Factorഀ Elastic Modulusഀ 1.00ഀ 29, 000.0 ksiഀ 4.00 ftഀ 0.00 ftഀ 0.00 ftഀ 4.00 ftഀ ~ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ DL 0.150ഀ #2 #3ഀ #4 -#5~ഀ #6 #7ഀ LL 0.500ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ k/ftഀ End Locationഀ ftഀ ftഀ Summaryഀ Lഀ Bem OKഀ aഀ Using: W8X10 section, Span = 4.OOft, Fy = 50.Oksiഀ Static Load Case Governsഀ Stressഀ End Fixity = Pinned-Pinned, Luഀ = 4.OOft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 1.320 k-ftഀ 19ഀ 194 k -ftഀ fb : Bending Stressഀ 2.028 ksiഀ .ഀ 29.492 ksiഀ Max. Deflection -0.004 inഀ fb / Fbഀ 0.069:1ഀ Length/DL Defl 46,506.3: 1ഀ Shearഀ 1.320 kഀ 26ഀ 826 kഀ Length/(DL+LL Defl) 11,277.1: 1ഀ fv : Shear Stressഀ 0.984 ksiഀ .ഀ 20.000 ksiഀ fv / Fvഀ 0.049 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ Maximumഀ DLഀ Onlyഀ LL LL+STഀ @ Center @ Centerഀ LL LL+STഀ @ Cants @ Cantsഀ Max. M + 1.32 k-ftഀ 0.32ഀ 1ഀ 32ഀ Max. M -ഀ .ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 1.32 kഀ 0.32ഀ 1ഀ 32ഀ k-ftഀ Shear @ Right 1.32 kഀ 0,32ഀ .ഀ 1ഀ 32ഀ kഀ .ഀ kഀ Center Defl. -0.004 inഀ Left Cant DO 0ഀ 000 inഀ -0.001ഀ -0.004ഀ -0.004ഀ 0.000ഀ 0.000 inഀ .ഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0.000 inഀ ...Qu1ery DO @ 0.000 ftഀ 0.000ഀ .ഀ 0.000ഀ .ഀ 0ഀ 000ഀ 0.000ഀ 0ഀ 00ഀ 0.000 inഀ .ഀ .ഀ 0ഀ 0.000 inഀ Reaction @ Left 1.32ഀ 0.32ഀ 1.32ഀ 1ഀ 32ഀ Reaction @ Rt 1.32ഀ 0.32ഀ 1.32ഀ .ഀ 1ഀ 32ഀ kഀ Fa calc'd per Eq. E2.2, K'Ur > Ccഀ .ഀ kഀ I Beam, Major Axis, 002,000 ` Cb / Fy)A,5ഀ UrT (510,000' Cb / Fy)A.5ഀ , Fb per Eq. F1-6ഀ Z~, roc,ഀ 1 Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Y! Fax: 303.623.6602ഀ Rev: 580006ഀ user: KW-0606238, ver 5.8.0, 1-Dec•2003 Steel Beam Designഀ (c)1983.2003 ENERCALC Engineering Software Page 2ഀ msഀ Description Roof Beam - RB103 5500.ecw:8195 Beaഀ .1c"wn rroperttesഀ W8X10ഀ Dept. hഀ 7.890 inഀ Weightഀ sഀ 10ഀ 05 #/ftഀ Web Thickഀ 0.170 inഀ Ixxഀ .ഀ 30.800 in4ഀ Widthഀ 3.940 inഀ lyyഀ 2.090 in4ഀ Flange Thickഀ 0.205 inഀ Sxxഀ 7.810 in3ഀ Areaഀ 2.96 in2ഀ Syyഀ 1.060 in3ഀ Rtഀ 0.990 inഀ 8-ഀ 3.220 inഀ Values for LRFD Design....ഀ R-yyഀ 0.841 inഀ Jഀ 0.040 in4ഀ Zxഀ 8.870 in3ഀ Cwഀ 30.90 in6ഀ Zyഀ 1.660 in3ഀ Kഀ 0.505 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ 7l Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.01 1 -Dec-2003 Steel Beam Design Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB104ഀ General Information Code Ref: AisC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W8X18 Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Span 8.00 ft BM Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 ft LL & ST Act Togetherഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 8.00 ftഀ umtrinuted Loadsഀ • #1ഀ #2 #ഀ 3ഀ DL 0.150ഀ LL 0.500ഀ STഀ Start Locationഀ End Location 8.000ഀ Sഀ ummaryഀ Using: W8X18 section, Span = 8.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 8.OOft, LDF = 1.000ഀ Actualഀ Momentഀ 5.343 k-ftഀ fb : Bending Stressഀ 4.218 ksiഀ fb / Fbഀ 0.159 : 1ഀ Shearഀ 2.671 kഀ fv : Shear Stressഀ 1.427 ksiഀ fv / Fvഀ 0.071 : 1ഀ Note! Short Term Loads Are WIND Loads.ഀ Beam OKഀ Static Load Case Governs Stressഀ Allowableഀ 33.699 k-ftഀ Max. Deflection -0ഀ 034 inഀ 26.605 ksiഀ .ഀ Length/DL Defl 11,139.5 :1ഀ Length/(DL+LL Defl) 2,799.9 :1ഀ 37.444 kഀ 20.000 ksiഀ t-orce & Stress 5umഀ These columns are Dead + Live Loadഀ placed as noted »ഀ DLഀ LLഀ LL+STഀ LLഀ LL+STഀ Maximumഀ Onlyഀ @ Centerഀ @ Centerഀ @ Cantsഀ @ Cantsഀ Max. M +ഀ 5.34 k-ftഀ 1.34ഀ 5ഀ 34ഀ Max. Mഀ .ഀ k-ftഀ Max. M @ Leftഀ k -ftഀ Max. M @ Rightഀ k-ftഀ k-ftഀ Shear @ Leftഀ 2.67 kഀ 0.67ഀ 2ഀ 67ഀ Shear @ Rightഀ 2.67 kഀ 0.67ഀ .ഀ 2ഀ 67ഀ kഀ .ഀ kഀ Center Defl.ഀ Left Cant Deflഀ -0.034 inഀ 000 inഀ 0ഀ -0.009ഀ -0.034ഀ -0.034ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ .ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0.000 inഀ .ഀ .ഀ 0.000ഀ 0.000 inഀ ...Query DO @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Leftഀ 2.67ഀ 0.67ഀ 2.67ഀ 2.67ഀ kഀ Reaction @ Rtഀ 2.67ഀ 0.67ഀ 2.67ഀ 2.67ഀ kഀ Fa calc'd per Eq. E2-2, K*Ur > Ccഀ #4'ഀ #5ഀ #6ഀ #7ഀ k/ftഀ k/ftഀ k/ftഀ ftഀ ftഀ I Beam, Major Axis, (102,000 * Cb / Fy)A.5 UrT (510,000 * Cb / Fy)A.5 , Fb per Eq. F1-6ഀ I Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / (I * d)ഀ V-r:~ !obഀ JOE) S OODU.UYഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, V -Dec-2003ഀ Steel Beam Design Page 2ഀ (c)19833--2 2003 3 ENERCALC ALC Engineering g Software 5500 ecw:8195 Beamsഀ Description Roof Beam - RB104ഀ aeciion rropertiesഀ Depthഀ Web Thickഀ Widthഀ Flange Thickഀ Areaഀ Rtഀ Values for LRFD Design....ഀ Jഀ Cwഀ W8X18ഀ ഀ -ഀ -ഀ 8.140 inഀ Weightഀ 17.87 #/ftഀ 0.230 inഀ Ixxഀ 61.900 in4ഀ 5.250 inഀ lyyഀ 7.970 in4ഀ 0.330 inഀ Sxxഀ 15.200 in3ഀ 5.26 in2ഀ Syyഀ 3.040 in3ഀ 1.390 inഀ R-xxഀ 3.430 inഀ R-yyഀ 1.230 inഀ 0.170 in4ഀ Zxഀ 17.000 in3ഀ 122.00 in6ഀ Zyഀ 4.660 in3ഀ Kഀ 0.630 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 10:14AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB105ഀ Multi-Span Steel Beamഀ _-f,ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ ueneral Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Left Cantഀ Spanഀ Spanഀ ftഀ 3.00ഀ 18.50ഀ Steel Sectionഀ w12x26ഀ w12x26ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.00ഀ 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.075ഀ 0.075ഀ Live Loadഀ k/ftഀ 0.250ഀ 0.250ഀ Point #1 DLഀ kഀ 0.920ഀ LLഀ kഀ 3.060ഀ @ Xഀ ftഀ 4.500ഀ Point #2 DLഀ kഀ 0.470ഀ LLഀ kഀ 1.560ഀ @ Xഀ ftഀ •9.000ഀ Point #3 DLഀ kഀ 0.650ഀ LLഀ k Iഀ 2.000ഀ @ Xഀ ft Iഀ 12.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 40.10ഀ @ X =ഀ ftഀ 0.00ഀ 9.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -1.46ഀ Max @ Right Endഀ k-ft lഀ -1.46ഀ 0.00ഀ fb : Actualഀ psiഀ 525.6ഀ 14,411.9ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 33,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 346.9ഀ 2,871.5ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 8.07ഀ Shear @ Rightഀ kഀ 0.97ഀ 6.60ഀ Reactions...ഀ DL @ Leftഀ k !ഀ 0.00ഀ 2.10ഀ LL @ Leftഀ k~ഀ 0.00ഀ 6.94ഀ Total @ Leftഀ k jഀ 0.00ഀ 9.05ഀ DL @ Rightഀ k iഀ 2.10ഀ 1.55ഀ LL @ Rightഀ kഀ 6.94ഀ 5.05ഀ Total @ Rightഀ kഀ 9.05ഀ 6.60ഀ Max. Deflectionഀ inഀ 0.208ഀ -0.407ഀ @ X =ഀ ftഀ 0.00ഀ 9.13ഀ Span/Deflection Ratioഀ Iഀ 345.4ഀ 545.8ഀ ouery Valuesഀ Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00ഀ Shear k 0.00 8.07 0.00 0.00 0.00 0.00 0.00 0.00ഀ Moment k-ft 0.00 -1.46 0.00 0.00 0.00 0.00 0.00 0.00ഀ Max. Deflection in ~ 0.2085 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scope :ഀ Fax: 303.623.6602ഀ RovSannn~ഀ User: -20 , Ve, -Dec-2003ഀ g So Multi-Span Steel Beam Page 1ഀ (c)19833-2003 3 ENE ENERCALC LC Engineering Software 5500.ecw:8195 Beamsഀ i -M7 Description Roof Beam - RB106ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factorഀ 1.00ഀ Spans Considered Continuous Over Suഀ pportsഀ Span Informationഀ Descriptionഀ I Left Cantഀ Spanഀ Right Cantഀ Span ftഀ 3.00ഀ 18.50ഀ 6.50ഀ Steel Sectionഀ w8x24ഀ w8x24ഀ w8x24ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 3.00ഀ 0.50ഀ 6.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.150ഀ 0.150ഀ 0.150ഀ Live Load k/ftഀ 0.500ഀ 0.500ഀ 0.500ഀ Resultsഀ Mmax @ Cntr k-ftഀ 0.00ഀ 19.74ഀ 0.00ഀ @ X = ftഀ lഀ 0.00ഀ 8.39ഀ 6.50ഀ Max @ Left End k -ftഀ 0.00ഀ -2.92ഀ -13.73ഀ Max @ Right End k-ftഀ -2.92ഀ -13.73ഀ 0.00ഀ fb : Actual psiഀ i 1,682.8ഀ 11,358.1ഀ 7,900.0ഀ Fb : Allowable psi!ഀ 33,000.0ഀ 33,000.0ഀ 30,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ Bending OKഀ psiഀ 1,003.7ഀ 3,395.3ഀ 2,174.6ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.00ഀ 5.43ഀ 4.22ഀ Shear @ Right kഀ 1.95ഀ 6.60ഀ 0.00ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 1.70ഀ 2.50ഀ LL @ Left kഀ 0.00ഀ 5.68ഀ 8.32ഀ Total @ Left kഀ 0.00ഀ 7.38ഀ 10.82ഀ DL @ Right kഀ 1.70ഀ 2.50ഀ 0.00ഀ LL @ Right k jഀ 5.68ഀ 8.32ഀ 0.00ഀ Total @ Right k Iഀ 7.38ഀ 10.82ഀ 0.00ഀ Max. Deflection inഀ 0.238ഀ -0.459ഀ 0.255ഀ @ X = ftഀ 0.00ഀ 8.88ഀ 6.50ഀ Span/Deflection Ratioഀ 302.8ഀ 483.9ഀ 612.4ഀ Query Valuesഀ Location ft j 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0ഀ 00ഀ Shear kഀ 0.00ഀ 5.43ഀ 4.22ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ .ഀ 0.00ഀ Moment k-ftഀ Maxഀ Dഀ flഀ tiഀ 0.00ഀ -2.92ഀ -13.73ഀ 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0.00ഀ .ഀ eഀ ecഀ on in!ഀ 0.2378ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Ds9nr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580017ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB107ഀ Multi-Span Steel Beamഀ -ഀ Page 1ഀ 5500.ecw:8195 Beamഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Spanഀ Span ftഀ 4.00ഀ 4.50ഀ Steel Sectionഀ wlox12ഀ Wlox12ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Length ftഀ 4.00ഀ 4.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.180ഀ 0.180ഀ Live Load k/ft Iഀ 0.600ഀ 0.600ഀ Hesui'tsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 0.09ഀ @ X =ഀ ftഀ 0.00ഀ 4.02ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -6.24ഀ Max @ Right Endഀ k-,ftഀ -6.24ഀ 0.00ഀ fb : Actualഀ psi'ഀ 6,868.6ഀ 6,868.6ഀ Fb : Allowableഀ psiഀ 29,248.4ഀ 28,163.3ഀ fv:Actualഀ Bending OKഀ Bending OKഀ psiഀ 1,663.7ഀ 1,675.3ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 3.14ഀ Shear @ Rightഀ kഀ 3.12ഀ 0.37ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 1.44ഀ LL @ Leftഀ kഀ 0.00ഀ 4.82ഀ Total @ Leftഀ kഀ ~ഀ 0.00ഀ 6.26ഀ DL @ Rightഀ kഀ 1.44ഀ 0.08ഀ LL @ Rightഀ kഀ 4.82ഀ 0.28ഀ Total @ Rightഀ kഀ 6.26ഀ 0.37ഀ Max. Deflectionഀ inഀ -0.056ഀ 0.005ഀ @ X =ഀ ft lഀ 0.00ഀ 1.56ഀ Span/Deflection Ratioഀ Iഀ 1,713.7ഀ 11,652.0ഀ Query Valuesഀ m _ x .ഀ Locationഀ ft jഀ .ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Shearഀ kഀ 0.00ഀ 3.14ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0ഀ 00ഀ Momentഀ Maഀ Dഀ flഀ iഀ k-ftഀ !ഀ 0.00ഀ -6.24ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ x.ഀ eഀ ectഀ onഀ inഀ -0.0560ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ (c)1983-2003 ENEFഀ Descriptionഀ Z.t,~ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ 5.8.0, 1-Dec-2003 Multi -Span Steel Beam Page 1ഀ C Engineering Softwareഀ 5500.ecw:8195 Beamsഀ Roof Beam - RB108ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC 2003 NFPA 5000ഀ Fy Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Deഀ Loadsഀ mmmommiagmsഀ Live Load Usedഀ Dead Loadഀ Live Loadഀ Scrip onഀ Spanഀ Cantഀ Spanഀ ftഀ 4.00ഀ 6.00ഀ Steel Sectionഀ w8x10ഀ wsxioഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 4.00.ഀ 6.00ഀ ? I Yes Yesഀ k/ft I 0.150 0.150ഀ k/ft 0.500 0.500ഀ Query Valuesഀ Location ft 0.00ഀ Shear k 0.00ഀ Moment k-ft 0.00ഀ Max. Deflection in I -0.0756ഀ rsesu Itsഀ Mmax @ Cntr k-ftഀ 0.00ഀ 0.90ഀ @ X = ftഀ 0.00ഀ 4.32ഀ Max @ Left End k-ftഀ 0.00ഀ -5.20ഀ Max @ Right End k-ftഀ ;ഀ -5.20ഀ 0.00ഀ fb : Actual psiഀ lഀ 7,992.5ഀ 7,992.5ഀ Fb : Allowable psiഀ 29,492.2ഀ 24,690.8ഀ fv :Actualഀ Bending OKഀ Bending OKഀ psiഀ 1,938.4ഀ 2,100.0ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.00ഀ 2ഀ 82ഀ Shear @ Right kഀ 2.60ഀ .ഀ 1.08ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 1.25ഀ LL @ Left kഀ 0.00ഀ 4.17ഀ Total @ Left k iഀ 0.00ഀ 5.42ഀ DL @ Right kഀ 1.25ഀ 0.25ഀ LL @ Right kഀ 4.17ഀ 0.83ഀ Total @ Right kഀ 5,42ഀ 1.08ഀ Max. Deflection in iഀ -0.076ഀ 0.005ഀ @ X = ft jഀ 0.00ഀ 1.28ഀ Span/Deflection Ratioഀ 1,269.0ഀ 15,028.1ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 2.82ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ -5.20ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ 8000fiഀ Descriptionഀ i--'b i tഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ Ver5.8.0, 1-Dec-2003ഀ CALC Engineering Softwareഀ Roof Beam - RB109ഀ General Informationഀ Steel Section : W8X10ഀ Center Spanഀ Left Cant.ഀ Right Cantഀ Lu : Unbraced Lengthഀ Distributed Loadsഀ #1ഀ DL 0.150ഀ LL 0.500ഀ STഀ Start Locationഀ End Locationഀ -ഀ Steel Beam Designഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy 50.00k siഀ Pinned-Pinned Load Duration Factor 1.00ഀ 11.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.Oksiഀ 0.00 ft LL & ST Act Togetherഀ 0.00 ftഀ 0.50 ftഀ #2 #3ഀ Using: W8X10 section, Span = 11.00ft, Fy = 50.0ksiഀ End Fixity = Pinned-Pinned, Lu = 0.50ft, LDF = 1.000ഀ Actualഀ Momentഀ 9.983 k-ftഀ fb : Bending Stressഀ 15.339 ksiഀ fb / Fbഀ 0.511 : 1ഀ Shearഀ 3.630 kഀ fv : Shear Stressഀ 2.707 ksiഀ fv / Fvഀ 0.135 : 1ഀ Force & Stress Summaഀ Note! Short Term Loads Are WIND Loads.ഀ #4 #5 #6 #7ഀ k/ftഀ k/ftഀ k/ftഀ ftഀ ftഀ Beam OKഀ Static Load Case Governs Stressഀ Allowableഀ 19.525 k-ftഀ 30.000 ksiഀ Max. Deflection -0.243 inഀ Length/DL Defl 2,236.2: 1ഀ Length/(DL+LL Defl) 542.3: 1ഀ 26.826 kഀ 20.000 ksiഀ <<-- These columns are Dead + Live Loadഀ placed as notedഀ Maximumഀ DL LLഀ Only @ Centerഀ LL+STഀ @ Centerഀ LLഀ @ Cantsഀ LL+STഀ @ Cantsഀ Max. M +ഀ 9.98 k-ftഀ 2.42ഀ 9ഀ 98ഀ Max. M -ഀ .ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Leftഀ 3.63 kഀ 0.88ഀ 3ഀ 63ഀ k-ftഀ Shear @ Rightഀ 3.63 kഀ 0.88ഀ .ഀ 3ഀ 63ഀ kഀ .ഀ kഀ Center Defl.ഀ Left Cant Deflഀ -0.243 inഀ 000inഀ 0ഀ -0.059ഀ -0.243ഀ -0.243ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ .ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0.000 inഀ ...Query DO @ഀ 0.000 ftഀ 0.000ഀ .ഀ 0.000ഀ .ഀ 0ഀ 000ഀ 0.000ഀ 0ഀ 00ഀ 0.000 inഀ .ഀ .ഀ 0ഀ 0.000 inഀ Reaction @ Leftഀ 3.63ഀ 0.88ഀ 3.63ഀ 3ഀ 63ഀ Reaction @ Rtഀ 3.63ഀ 0.88ഀ 3.63ഀ .ഀ 3ഀ 63ഀ kഀ Fa calc'd per Eq. E2-ഀ 1, K'L/r < Ccഀ .ഀ kഀ I Beam Passes Table B5.1 but Non-Compact, Fb Per Eq. F1-4ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ # 5500ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, J13 DEC 05 02ഀ z` 5 Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Fax: 303.623.6602 Scope:ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Software Steel Beam Design Page 2ഀ Description Roof Beam - RB109 ssoo.ecws,ss seamsഀ Section Properties W8X10ഀ Depthഀ Web Thickഀ 7.890 inഀ Weightഀ 10.05 #/ftഀ Widthഀ 0.170 inഀ Ixxഀ 30.800 in4ഀ Flange Thickഀ 3.940 inഀ lyyഀ 2.090 in4ഀ Areaഀ 0.205 inഀ Sxxഀ 7.810 in3ഀ Rtഀ 2.96 in2ഀ Syyഀ 1.060 in3ഀ 0.990 inഀ R-xxഀ 3.220 inഀ Values for LRFD Design....ഀ R-yyഀ 0.841 inഀ 1ഀ 0.040 in4ഀ Zxഀ 8.870 in3ഀ Cwഀ 30.90 in6ഀ Zyഀ 1.660 in3ഀ Kഀ 0.505 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ T' f Fax: 303.623.6602ഀ Rev: 580006 Page 1ഀ User: KW-0606238, ver 5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB110ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W8X18ഀ Fyഀ 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factorഀ 1.00ഀ Center Spanഀ 15.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulusഀ 29,000.Oksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 0.50 Itഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads. IIIഀ Aഀ MMMഀ #1ഀ #2ഀ #3 #4ഀ #5 #6ഀ #7ഀ DL 0.150ഀ krftഀ LL 0.500ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Locationഀ ftഀ Summaryഀ Beam OKഀ Static Load Caseഀ Governs Stressഀ Using: W8X18 section, Span =ഀ 15.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 0.50ft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 18.784 k-ftഀ 41.800 k-ftഀ Max. Deflectionഀ -0.424 inഀ fb : Bending Stressഀ 14.829 ksiഀ .33.000 ksiഀ Length/DL Deflഀ 1,689.9 :1ഀ fb / Fbഀ 0.449 : 1ഀ Length/(DL+LL Defi)ഀ 424.8 :1ഀ Shearഀ 5.009 kഀ 37.444 kഀ fv : Shear Stressഀ 2.675 ksiഀ 20.000 ksiഀ fv / Fvഀ 0.134 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as notedഀ DLഀ LL LL+ST LL LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cants @ Cantsഀ Max. M + 18.78 k-ftഀ 4.72ഀ 18.78 k-ftഀ Max. M -ഀ k-ftഀ Maxഀ M @ Leftഀ k-ftഀ .ഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 5.01 kഀ 1.26ഀ 5.01 kഀ Shear @ Right 5.01 kഀ 1.26ഀ 5.01 kഀ Center Defl. -0.424 inഀ -0.107ഀ -0.424ഀ Left Cant DefI O.000inഀ 0.000ഀ 0.000ഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ Reaction @ Left 5.01ഀ 1.26ഀ 5.01ഀ Reaction @ Rt 5.01ഀ 1.26ഀ 5.01ഀ Fa calc'd per Eq. E2-1, K'L/r < Ccഀ I Beam Passes Table B5.1, Fb per Eq.ഀ F1-1, Fb = 0.66 FYഀ -0.424ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000 inഀ 5.01ഀ kഀ 5.01ഀ kഀ A 1Uഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ f Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 2ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB110ഀ Section Propertiesഀ W8X18ഀ Depthഀ 8.140 inഀ Weightഀ 17.87 #/ftഀ Web Thickഀ 0.230 inഀ Ixxഀ 61.900 in4ഀ Widthഀ 5.250 inഀ lyyഀ 7.970 in4ഀ Flange Thickഀ 0.330 inഀ Sxxഀ 15.200 in3ഀ Areaഀ 5.26 in2ഀ Syyഀ 3.040 in3ഀ Rtഀ 1.390 inഀ R-xxഀ 3.430 inഀ Values for LRFD Design....ഀ R-yyഀ 1.230 inഀ 1ഀ 0.170 in4ഀ Zxഀ 17.000 in3ഀ Cwഀ 122.00 in6ഀ Zyഀ 4.660 in3ഀ Kഀ 0.630 inഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ i 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ Page 1ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ 5500.ecw:8195 Beamsഀ Description Roof Beam - RB111ഀ General informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W8X35ഀ Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Spanഀ 20.00 ftഀ Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 0.50 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4 #5 9rn #7ഀ DL 0.150ഀ k/ftഀ LL 0.500ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Locationഀ ftഀ Summaryഀ Iഀ Beam OKഀ Static Load Caseഀ Governs Stressഀ Using: W BX35 section, Span = 20.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 0.50ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 34.249 k-ftഀ 85.800 k-ftഀ Max. Deflectionഀ -0.670 inഀ fb : Bending Stress 13.173 ksiഀ 33.000 ksiഀ Length/DL Deflഀ 1,327.3: 1ഀ fb / Fb 0.399 : 1ഀ Length/(DL+LL Defl)ഀ 358.5: 1ഀ Shear 6.850 kഀ 50.344 kഀ fv : Shear Stress 2.721 ksiഀ 20.000 ksiഀ fv / Fv 0.136 : 1ഀ Force & Stress Summaryഀ « These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 34.25 k-ft 9.25 34.25 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 6.85 kഀ 1.85ഀ 6.85ഀ kഀ Shear @ Right 6.85 kഀ 1.85ഀ 6.85ഀ kഀ Center Defl. -0.670 inഀ -0.181ഀ -0.670ഀ -0.670ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query DO @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 6.85ഀ 1.85ഀ 6.85ഀ 6.85ഀ kഀ Reaction @ Rt 6.85ഀ 1.85ഀ 6.85ഀ 6.85ഀ kഀ Fa calc'd per Eq. E2-1, K'Ur < Ccഀ I Beam Passes Table B5.1, Fb per Eq. Fഀ 1-1, Fb = 0.66 Fyഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ fഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.ഀ 0, 1-Dec-2003 Steel Beam Designഀ Page 2ഀ (c)1983-2003 ENERCALC Eഀ ngineering Software _ഀ 5500.ecw:8195 Beamsഀ Description Roof Beam - RB111ഀ ഀ Section Propertiesഀ W8X35ഀ Depthഀ 8.120 inഀ Weightഀ 34.99 #/ftഀ Web Thickഀ 0.310 inഀ ixxഀ 127.000 in4ഀ Widthഀ 8.020 inഀ lyyഀ 42.600 in4ഀ Flange Thickഀ 0.495 inഀ Sxxഀ 31.200 in3ഀ Areaഀ 10.30 in2ഀ Syyഀ 10.600 in3ഀ Rtഀ 2.200 inഀ R-xxഀ 3.510 inഀ Values for LRFD Design....ഀ R-yyഀ 2.030 inഀ Jഀ 0.770 in4ഀ Zxഀ 34.700 in3ഀ Cwഀ 619.00 in6ഀ Zyഀ 16.100 in3ഀ Kഀ 0.889 inഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ r a;.ഀ Description Roof Beam - RB112ഀ 777ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Steel Sectionഀ End Fixityഀ Unbraced Lengthഀ Loadsഀ Live Load Used Thisഀ Dead Loadഀ Live Loadഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ ftഀ ftഀ k/ftഀ k/ftഀ k-ftഀ ftഀ k-ftഀ k-ftഀ psiഀ psiഀ psiഀ psiഀ Spanഀ cantഀ 12.00ഀ 6.50ഀ waxesഀ wsxlaഀ Pin-Pinഀ Pin-Freeഀ 12.00ഀ 6.50ഀ Yes Yesഀ 0.150 0.150ഀ 0.500 0.500ഀ 5.84ഀ 0.00ഀ 4.24ഀ 6.50ഀ 0.00ഀ -13.73ഀ -13.73ഀ 0.00ഀ 10,834.2ഀ 10,834.2ഀ 17,736.5ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ 2,694.3ഀ 2,256.7ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 2.76ഀ 4.22ഀ Shear @ Rightഀ kഀ 5.04ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.64ഀ 2.14ഀ LL @ Leftഀ kഀ 2.12ഀ 7.13ഀ Total @ Leftഀ kഀ 2.76ഀ 9.27ഀ DL @ Rightഀ kഀ 2.14ഀ 0.00ഀ LL @ Rightഀ kഀ 7.13ഀ 0.00ഀ Total @ Rightഀ kഀ 9.27ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.054ഀ -0.190ഀ @ X =ഀ ftഀ 4.72ഀ 6.50ഀ Span/Deflection Ratioഀ 2,652.0ഀ 820.0ഀ (query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 2.76ഀ 4.22ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -13.73ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 3:53PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ "ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ Page 1ഀ (c)1983-2003 ENERCALCഀ Enaineerina Softwareഀ 5500.ecw:8195 Beamsഀ Description Roof Beam - RB113ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W8X18ഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Spanഀ 4.00 ft Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ft LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 4.00 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2 #3 #4ഀ #5 #6 #7ഀ DL 0.120ഀ k/ftഀ LL 0.300ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Locationഀ ftഀ Summaryഀ Beam OKഀ Static Load Case Governs Stressഀ Using: W8X18 section, Span = 4.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 4.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 0.876 k-ftഀ 41.800 k-ftഀ Max. Deflectionഀ -0.001 inഀ fb : Bending Stress 0.691 ksiഀ 33.000 ksiഀ Length/DL DOഀ 108507.4: 1ഀ fb / Fb 0.021 : 1ഀ Length/(DL+LL Defl)ഀ 34,164.6: 1ഀ Shear 0.876 kഀ 37.444 kഀ fv : Shear Stress 0.468 ksiഀ 20.000 ksiഀ fv / Fv 0.023 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 0.88 k-ft 0.28 0.88 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 0.88 kഀ 0.28ഀ 0.88ഀ kഀ Shear @ Right 0.88 kഀ 0.28ഀ 0.88ഀ kഀ Center Defl. -0.001 inഀ -0.000ഀ -0.001ഀ -0.001ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query DO @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 0.88ഀ 0.28ഀ 0.88ഀ 0.88ഀ kഀ Reaction @ Rt 0.88ഀ 0.28ഀ 0.88ഀ 0.88ഀ kഀ Fa caldd per Eq. E2-1, K*Ur < Ccഀ I Beam Passes Table B5.1, Fb per Eq. F1-1, Fb = 0.66 Fyഀ ( gyഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:53PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Page 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB113ഀ Section Propertiesഀ W8X18ഀ Depthഀ 8.140 inഀ Weightഀ 17.87 #/ftഀ Web Thickഀ 0.230 inഀ Ixxഀ 61.900 in4ഀ Widthഀ 5.250 inഀ lyyഀ 7.970 in4ഀ Flange Thickഀ 0.330 inഀ Sxxഀ 15.200 in3ഀ Areaഀ 5.26 in2ഀ Syyഀ 3.040 in3ഀ Rtഀ 1.390 inഀ R-xxഀ 3.430 inഀ Values for LRFD Design....ഀ R-yyഀ 1.230 inഀ Jഀ 0.170 in4ഀ Zxഀ 17.000 in3ഀ Cwഀ 122.00 in6ഀ Zyഀ 4.660 in3ഀ Kഀ 0.630 inഀ 7,Y ?ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ t 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:53PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scope :ഀ Fax: 303.623.6602ഀ Rev: 580006 Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB114ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W12X40ഀ Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Spanഀ 22.00 ftഀ Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 5.00 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4 #5 #6 #7ഀ DL 0.300ഀ k/ftഀ LL 1.000ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Location 22.000ഀ ftഀ Summaryഀ Beam OKഀ ഀ Static Load Caseഀ Governs Stressഀ Using: W 12X40 section, Span = 22.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 5.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 81.075 k-ftഀ 141.625 k-ftഀ Max. Deflectionഀ -0.793 inഀ fb : Bending Stress 18.891 ksiഀ 33.000 ksiഀ Length/DL Deflഀ 1,311.3: 1ഀ fb / Fb 0.572 : 1ഀ Length/(DL+LL Defl)ഀ 332.8: 1ഀ Shear 14.741 kഀ 70.446 kഀ fv : Shear Stress 4.185 ksiഀ 20.000 ksiഀ fv / Fv 0.209 : 1ഀ LForce & Stress Summaryഀ <<- These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 81.07 k-ft 20.57 81.07 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 14.74 kഀ 3.74ഀ 14.74ഀ kഀ Shear @ Right 14.74 kഀ 3.74ഀ 14.74ഀ kഀ Center Defl. -0.793 inഀ -0.201ഀ -0.793ഀ -0.793ഀ 0.000ഀ 0.000 inഀ Left Cant DefI O.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Def! 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query DO @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 14.74ഀ 3.74ഀ 14.74ഀ 14.74ഀ kഀ Reaction @ Rt 14.74ഀ 3.74ഀ 14.74ഀ 14.74ഀ kഀ Fa calc'd per Eq. E2-1, K*Ur < Ccഀ I Beam Passes Table B5.1, Fb per Eq. Fഀ 1-1, Fb = 0.66 Fyഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 3:53PM, 13 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scope :ഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ Page 2ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ 5500.ecw:8195 Beamsഀ Descriptionഀ Roof Beam - RB114ഀ Section Propertiesഀ W12X40ഀ Depthഀ 11.940 inഀ Weightഀ 40.08 #/ftഀ Web Thickഀ 0.295 inഀ Ixxഀ 307.000 in4ഀ Widthഀ 8.005 inഀ lyyഀ 44.100 in4ഀ Flange Thickഀ 0.515 inഀ Sxxഀ 51.500 in3ഀ Areaഀ 11.80 in2ഀ Syyഀ 11.000 in3ഀ Rtഀ 2.140 inഀ R-xxഀ 5.130 inഀ Values for LRFD Design....ഀ R-yyഀ 1.940 inഀ Jഀ 0.950 in4ഀ Zxഀ 57.000 in3ഀ Cwഀ 1,440.00 in6ഀ Zyഀ 16.800 in3ഀ Kഀ 1.020 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ iഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:53PM, 13 DEC 05 Denver, CO 80202 Description Lodge Expansionഀ 303.623.4927 Scope :ഀ _ഀ Fax: 303.623.6602ഀ Rev: 580006 Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ sAIAഀ Description Roof Beam - RB115ഀ General Informationഀ Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W16X31ഀ Fyഀ 50.00ksiഀ Pinned Pinnedഀ Load Duration Factorഀ 1.00ഀ Center Spanഀ 26.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulusഀ 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 4.00 ftഀ Note! Short Term Loads Are WIND Loads.ഀ Trapezoidal Loadsഀ mm- 77ഀ ^ഀ #1 DL @ Leftഀ 0.270ഀ LL @ Leftഀ 0.900ഀ ST @ Leftഀ k/ftഀ Start ftഀ DL @ Righiഀ 0.270ഀ LL @ Rightഀ 0.900ഀ ST @ Rightഀ k/ftഀ End 7.000 ftഀ #2 DL @ Leftഀ 0.270ഀ LL @ Leftഀ 0.900ഀ ST @ Leftഀ k/ftഀ Start 7.000 ftഀ DL @ Righiഀ 0.090ഀ LL @ Rightഀ 0.300ഀ ST @ Righiഀ k/ftഀ End 26.000 ftഀ Summaryഀ Beam OKഀ -Fഀ Static Load Caseഀ Governs Stressഀ Using: W 16X31 section, Span = 26.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 4.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 80.080 k-ftഀ 129.800 k-ftഀ Max. Deflectionഀ -0.888 inഀ fb : Bending Stress 20.359 ksiഀ 33.000 ksiഀ Length/DL DOഀ 1,372.2: 1ഀ fb / Fb 0.617 : 1ഀ Length/(DL+LL Defl)ഀ 351.5: 1ഀ Shear 13.808 kഀ 87.340 kഀ fv : Shear Stress 3.162 ksiഀ 20.000 ksiഀ fv / Fv 0.158 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 80.08 k-ft 20.48 80.08 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ k-ftഀ Max. M @ Rightഀ Shear @ Leftഀ 13.81 kഀ 3.50ഀ 13.81ഀ kഀ Shear @ Rightഀ 10.01 kഀ 2.62ഀ 10.01ഀ kഀ Center Defl.ഀ -0.888 inഀ -0.227ഀ -0.888ഀ -0.888ഀ 0.000ഀ 0.000 inഀ Left Cant Deflഀ 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Leftഀ 13.81ഀ 3.50ഀ 13.81ഀ 13.81ഀ kഀ Reaction @ Rtഀ 10.01ഀ 2.62ഀ 10.01ഀ 10.01ഀ kഀ Fa calc'd per Eq. E2-1, K'Ur < Ccഀ I Beam Passes Tableഀ B5.1, Fb per Eq. F1ഀ -1, Fb = 0.66 Fyഀ Section Propertiesഀ W16X31ഀ 11 ffil"ഀ Depthഀ 15.880 inഀ Weightഀ 30.98 #/ftഀ Web Thickഀ 0.275 inഀ Ixxഀ 375.000 in4ഀ Widthഀ 5.525 inഀ lyyഀ 12.400 in4ഀ Flange Thickഀ 0.440 inഀ Sxxഀ 47.200 in3ഀ Areaഀ 9.12 in2ഀ Syyഀ 4.490 in3ഀ Rtഀ 1.390 inഀ R-xxഀ 6.410 inഀ Values for LRFD Design....ഀ R-yyഀ 1.170 inഀ 1ഀ 0.460 in4ഀ Zxഀ 54.000 in3ഀ Cwഀ 739.00 in6ഀ Zyഀ 7.030 in3ഀ Kഀ 0.842 inഀ Company Monroe & Newell Engineers, Inc. Dec 14, 2005ഀ Designer Arthur Ashworth, PE 6:41 AMഀ Job Number : 5500.02 Roof Beam - RB116 - Bent Checked By:ഀ Basic Load Casesഀ i aeaa UL - I Iഀ 9 i Gnnw I SL I i I 11 1 2 !ഀ Joint Boundary Conditionsഀ I N3 Reaction Reaction Reactionഀ Hot Rolled Steel Design Parameters -ഀ Joint Coordinates and Temperaturesഀ Labelഀ X fftഀ Y ],ftഀ Z ft Temp F Detach From Diaഀ 1 N1ഀ 6ഀ 0ഀ 0_ഀ 0ഀ 2 N2ഀ 11.5ഀ 3.916667ഀ - 0ഀ 0ഀ ഀ 3 N3ഀ 17ഀ 2.083ഀ __-0ഀ ~ഀ 0ഀ Envelope Joint Displacementsഀ 1ഀ JUII IIഀ N1ഀ maxഀ n ulഀ 0ഀ rt.ഀ 18ഀ uഀ 0ഀ ഀ 18ഀ 0ഀ ഀ 1 0 1 0ഀ ഀ 1ഀ ഀ 0ഀ 4ഀ 2`ഀ minഀ 0ഀ 4ഀ 0ഀ 4 1ഀ 0'ഀ 1 0 1 0ഀ 1ഀ 0ഀ 18ഀ 3ഀ N2ഀ maxഀ 188ഀ 4ഀ 08ഀ 181ഀ 0ഀ 1 0 1 0ഀ 1ഀ 4.459e-3ഀ 4ഀ 4ഀ minഀ .027ഀ 18ഀ -.557ഀ 4ഀ 0ഀ 1 0 1 0ഀ 1ഀ 6.368e-4ഀ 18ഀ 5ഀ N3ഀ maxഀ .373ഀ 4 1ഀ 0'ഀ 18ഀ 0ഀ 1 0 1 0ഀ 1ഀ 0ഀ 1ഀ 6ഀ minഀ .053ഀ 18ഀ 0ഀ 4ഀ 0ഀ 1 1 0 1 0ഀ 1ഀ 0ഀ 1ഀ Envelope Joint Reactions -ഀ r. ev rl, Lal I.. K A7 n. w Inഀ JUII ILഀ 1 N1ഀ maxഀ /nഀ 467ഀ wഀ 4ഀ 10.366 4 0ഀ 1ഀ 0ഀ 1 0ഀ 1ഀ 0ഀ 1ഀ 2-ഀ minഀ 28ഀ 18ഀ 1.525 18 0:ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0''ഀ 1ഀ 3 N3ഀ maxഀ 0ഀ 1ഀ 15.109 4 1 0 1ഀ -ഀ 1ഀ 0 1ഀ iഀ 0ഀ 1ഀ 0ഀ 1 1ഀ 4 iഀ min 0ഀ 1ഀ 7ഀ 2.19 ' 18 " 0 jഀ 1ഀ ,1ഀ 0 'ഀ 1ഀ 0ഀ h 1ഀ 0ഀ 1ഀ 5 1 Totals: 1ഀ max 467ഀ 4ഀ 25.475 1 4 0ഀ 1ഀ 6 1ഀ min .28ഀ 18ഀ 3.715 18 0ഀ 1ഀ Member Distributed Loads (BLC 1 • dead)ഀ 1 1 Ml Y I I~ to U Iഀ MP y -.15 -.15 { 0 0ഀ Member Distributed Loads (BLC 2: snow)ഀ RISA-3D Version 5.Od [D:\Projects\5500\Roof Beam - RB116 - Bent.r3d] Page 1ഀ Company Monroe & Newell Engineers, Inc. Dec 14, 2005ഀ Designer Arthur Ashworth, PE 6:41 AMഀ Job Number : 5500.02 Roof Beam - RB116 - Bent Checked By:ഀ Joint Loads and Enforced Displacements (BLC 1 - dead)ഀ Joint Loads and Enforced Displacements (BLC 2: snow)ഀ Member Point Loadsഀ Hot Rolled Steel Propertiesഀ ..n. aan I V7.J.UL,i1ഀ Label t Ksiഀ u KJIഀ Iluഀ 3ഀ 65ഀ 49ഀ ഀ 36ഀ 1ഀ A36 29000ഀ 11154ഀ .ഀ .ഀ .ഀ 2ഀ A572G'rade50 29000ഀ 11154ഀ .3ഀ .65 `ഀ 49ഀ 50ഀ 3ഀ A992 29000ഀ 11154ഀ .3ഀ .65ഀ .49ഀ 50ഀ 4ഀ A500 42 29000ഀ 11154ഀ 3ഀ .65ഀ .49ഀ 42ഀ 5ഀ A500 46 29000ഀ 11154ഀ .3ഀ .65ഀ .49 1ഀ 46ഀ Envelope Member Section Deflectionsഀ Memberഀ Secഀ x mഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ NCഀ 1ഀ ഀ NCഀ 1ഀ 1ഀ M1ഀ 1ഀ iഀ maxഀ `minഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ NCഀ 1ഀ NCഀ 1ഀ 2ഀ 2ഀ maxഀ 0 1ഀ 18!ഀ 044ഀ -ഀ 18ഀ 0ഀ 1 1ഀ 0 1ഀ 1 1ഀ 6491.306ഀ 18ഀ NCഀ 1ഀ 3ഀ 4ഀ Iഀ minഀ 0ഀ 4ഀ .ഀ -.305ഀ '4ഀ 0ഀ 11ഀ 0ഀ 1 1ഀ 922.251 1ഀ 4ഀ NC (ഀ 1ഀ 5ഀ 3ഀ maxഀ 0 !ഀ 18ഀ -.077ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1 1ഀ 4164.824ഀ 18ഀ NCഀ 1ഀ 6ഀ minഀ 0ഀ 4ഀ -.54ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 592.909ഀ 4' Iഀ NCഀ 1ഀ 7ഀ 4ഀ maxഀ 0ഀ 18ഀ -.093 1ഀ 18ഀ 0 1ഀ 1 1ഀ 0ഀ 1ഀ 4933.627ഀ 18ഀ NC lഀ iഀ 8ഀ minഀ -`.001ഀ 4(ഀ -.648 iഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 704.359 1ഀ 4ഀ NCഀ 1ഀ 9ഀ 1ഀ 5ഀ maxഀ 0 1ഀ 18ഀ -.085 1ഀ 18ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ NCഀ 18ഀ NCഀ 1ഀ 101ഀ minഀ -.002ഀ 4ഀ -.588ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1 1ഀ NCഀ 4ഀ NCഀ 1ഀ 11ഀ M2ഀ 1ഀ Imaxഀ .355ഀ 4ഀ -.068ഀ 181ഀ 0ഀ 1 Iഀ 0ഀ 1)ഀ NC 1ഀ 181ഀ NC 1ഀ 1ഀ 12ഀ minഀ .051ഀ 18ഀ -.469ഀ 4ഀ 0ഀ 1 'ഀ 0ഀ 1 Iഀ NCഀ 1.4ഀ NCഀ 1ഀ 13ഀ 2ഀ maxഀ .355ഀ 4ഀ -.052ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ NCഀ 18ഀ `ഀ 1 NCഀ 1ഀ 14ഀ minഀ .051ഀ 18ഀ =.363ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 1701.388ഀ 4ഀ NCഀ 1ഀ 15ഀ 3ഀ maxഀ .354ഀ 4ഀ -.032ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ NCഀ 18ഀ NCഀ 1ഀ 16ഀ Iഀ minഀ .051ഀ 18ഀ -.223ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 1472.997ഀ 4ഀ NCഀ 1ഀ 17ഀ 4ഀ maxഀ .354ഀ 4ഀ -.009ഀ 18ഀ 0ഀ 1ഀ 0ഀ 11ഀ NCഀ 18ഀ 'ഀ NCഀ 1ഀ 18ഀ minഀ .051ഀ 18ഀ -.059ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 2338.187ഀ 4ഀ NCഀ 1ഀ RISA-3D Version 5.Od [D:\Projects\5500\Roof Beam - R131 16 - Bent.r3d] Page 2ഀ Member Primary Dataഀ Member Advanced Dataഀ f /ഀ Company Monroe & Newell Engineers, Inc. Dec 14, 2005ഀ Designer Arthur Ashworth, PE 6:41 AMഀ Job Number : 5500.02 Roof Beam - RB116 - Bent Checked By:ഀ Envelope Member Section Deflections (Continued)ഀ 20 1 1 min 1 .051 1 18 1 .017 118 1 0 1 1 0 1 1 1 NC 1 181 NC 1 1ഀ Envelope Member Section Forcesഀ nn i_ _ n~ __-r1., i.. T.........n. w h nA.....n L. ~An r,+f L_f+l Irഀ 1ഀ M 1 y 1'ഀ maxഀ 3 784 1ഀ 4ഀ 9.662ഀ 4 0 1ഀ 0ഀ 1 0ഀ 1ഀ 0ഀ 1ഀ 2ഀ [ഀ minഀ .757 'ഀ 118ഀ 1 ' 1.353 'ഀ 0ഀ 1181ഀ 1ഀ 0ഀ 1 0ഀ 1ഀ 0ഀ 1ഀ 1ഀ maxഀ 3.073 1ഀ 1ഀ 4ഀ 819ഀ 4 1ഀ 0ഀ 1ഀ 0ഀ 1 0ഀ 1ഀ -3.741ഀ 18ഀ 4ഀ 2ഀ mഀ .624ഀ 8ഀ 1ഀ 1ഀ 18ഀ 1 0ഀ 1ഀ 0ഀ 1 0ഀ 1ഀ -26.547ഀ 14ഀ 5ഀ 3 Iഀ maxഀ 2.362ഀ 4ഀ 5.976ഀ 4 Iഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ -6.742ഀ 18ഀ 6ഀ I minഀ .491 'ഀ 181ഀ .866ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0 'ഀ 1ഀ -47.495ഀ 4ഀ 7ഀ 4ഀ maxഀ 1.65ഀ 4ഀ 4.132ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ -9.004ഀ 18ഀ 8ഀ minഀ l` .358 'ഀ 18ഀ .623 'ഀ 18ഀ 0ഀ 1 1ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ -62.845 +ഀ 4'ഀ 9ഀ 5ഀ max,ഀ .939ഀ 4ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ -10.527ഀ 1ഀ 81ഀ 10ഀ •ഀ minഀ ..225ഀ 18ഀ ' .38ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1 1ഀ -72.597ഀ 4ഀ 11ഀ M2ഀ 1ഀ maxഀ 3.73ഀ 4 1ഀ -1.554ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ -10.527ഀ 18ഀ 12ഀ minഀ .614 "ഀ 18ഀ -10.71ഀ 4ഀ " 0ഀ 1 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ -72.597ഀ 4ഀ 13ഀ 2ഀ maxഀ 3.992ഀ 4 11ഀ -1.685ഀ 18ഀ 0ഀ 1ഀ 0 1 1ഀ 0ഀ 1ഀ -8.18 1ഀ 18ഀ 14ഀ Lഀ minഀ .633 1ഀ 181ഀ -11.6161ഀ 4 1ഀ ' 0ഀ 1ഀ 0 1ഀ 0ഀ 1ഀ -56.417ഀ 4ഀ 15ഀ 3ഀ maxഀ 4.254 1ഀ 4 1ഀ -1.816 1ഀ 181ഀ 0 1ഀ 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ -5.643ഀ 18ഀ 16 'ഀ Iഀ minഀ .653 1ഀ 18,ഀ -12.522ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ " 0ഀ 1ഀ -.38.924ഀ 4ഀ 17ഀ 1ഀ 4 lഀ maxഀ 4.516ഀ 4ഀ -1.947ഀ 18ഀ 0 1ഀ 1 1ഀ 0 1ഀ 1ഀ 1 0ഀ 1ഀ -2.916 1ഀ 18ഀ 18ഀ Iഀ minഀ .673 1ഀ 181ഀ -13.427ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 1 0ഀ 1 1ഀ -20.118ഀ 4ഀ 19ഀ 5ഀ maxഀ 4.779ഀ 4ഀ -2.078ഀ 18ഀ 0 1ഀ 1 1ഀ 0ഀ 1 1ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ 20ഀ Iഀ minഀ .693. 1ഀ 181ഀ -14.333ഀ 4ഀ - 0 1ഀ 1ഀ - 0ഀ 1ഀ 0ഀ 1ഀ 0'ഀ 1ഀ Envelope Member Section Stressesഀ 1ഀ M1ഀ 1ഀ maxഀ .495ഀ 4 3.438 4 0ഀ 1 0ഀ 1ഀ 14 0 1ഀ 0 1ഀ 0ഀ 1ഀ 2ഀ minഀ .099ഀ .482 18! 0ഀ ( 1' 0ഀ 1ഀ 0 1ഀ 0 1ഀ 0ഀ 1ഀ 3ഀ 2ഀ max.ഀ .402ഀ 4ഀ 2.782 14ഀ 1 0ഀ 1 1ഀ 9.541ഀ 4ഀ -1.344ഀ 18ഀ 1 0ഀ 1ഀ 0ഀ 1ഀ 4ഀ minഀ 1 .082ഀ 18ഀ .395ഀ 18ഀ 0ഀ 1ഀ 1.344ഀ 18ഀ -9.541ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 5ഀ 3ഀ maxഀ .309ഀ 4ഀ 2.126ഀ 4ഀ 0ഀ 1ഀ 17.07ഀ 4ഀ .-2.423ഀ 118ഀ 0ഀ 1ഀ 0ഀ 1ഀ 6ഀ minഀ .064ഀ 18ഀ .308ഀ 118ഀ 1 0ഀ 1ഀ 2.423ഀ 18ഀ =17.07ഀ 1 4ഀ 0ഀ i 1ഀ 0ഀ 1ഀ 7ഀ 4ഀ maxഀ .216ഀ 4ഀ 1.47ഀ 4 1ഀ 0ഀ 1ഀ 22.587ഀ 4ഀ -3.236ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1 1ഀ 8ഀ !ഀ 'minഀ - O47ഀ 18ഀ 1 .222:ഀ 18ഀ 0ഀ 1ഀ -:3.236ഀ 18ഀ 2.587ഀ 14ഀ 0ഀ 1ഀ 0 :ഀ 1ഀ 9ഀ 5ഀ maxഀ .123ഀ 4ഀ .814 1ഀ 4ഀ 0ഀ 1ഀ 26.092ഀ 4 1ഀ -3.783ഀ 18ഀ 0ഀ 1ഀ 0ഀ 1ഀ 10`ഀ I minഀ .029ഀ 18ഀ .135ഀ 11`8ഀ 0ഀ 1ഀ 3.783ഀ 181ഀ -26.092ഀ 4ഀ 0ഀ 1ഀ '0ഀ 1ഀ i 11 1ഀ M2 1ഀ 1 iഀ maxഀ .488ഀ 4ഀ -.553 1ഀ 1811ഀ 0 1ഀ 1ഀ 26.092ഀ 4ഀ -3.783ഀ 181ഀ 0ഀ 1ഀ 0 1ഀ 1ഀ 12ഀ 1ഀ minഀ .08ഀ 181ഀ -3.811ഀ 4ഀ 0ഀ 1ഀ 3.783ഀ 18ഀ -26.092ഀ 4ഀ 0ഀ 1ഀ 0ഀ 1ഀ 13ഀ 2ഀ maxഀ .522 1ഀ 4 1ഀ -.599 1ഀ 18ഀ 0ഀ 1ഀ 20.277ഀ 4ഀ -2.94 1ഀ 181ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ 14ഀ minഀ .083ഀ 18ഀ -4.133ഀ 4ഀ 0ഀ 1ഀ 2.94ഀ 8ഀ . -20.277ഀ 4ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ 15ഀ 3ഀ maxഀ .556 1ഀ 4ഀ -.646 1ഀ 18ഀ 0ഀ 1ഀ 13.99ഀ 4ഀ -2.028ഀ 18ഀ 0 1ഀ 1 1ഀ 0ഀ 1ഀ 16ഀ min 1ഀ .085ഀ 18;ഀ _4.455 1ഀ 41ഀ 0ഀ 1ഀ 2.02811ഀ 181ഀ " =13.99ഀ `4 1ഀ 0ഀ 1 .ഀ 0ഀ 1ഀ 17ഀ 1ഀ 4ഀ max.ഀ .59ഀ 4ഀ -.693ഀ 181ഀ 0 1ഀ 1 1ഀ 7.231ഀ 4 1ഀ -1.048ഀ 18'ഀ 0ഀ 1ഀ 0ഀ 1ഀ 18ഀ minഀ .088ഀ 18ഀ -4.777ഀ 4`ഀ 0 Iഀ 1ഀ 1.048ഀ 18ഀ -7.231ഀ ` 4ഀ - 0-ഀ 1ഀ 0ഀ 1ഀ 19 !ഀ 5 1ഀ max 1ഀ .625 1ഀ 4ഀ -.739 1ഀ 181ഀ 0 1ഀ 1 1ഀ 0 1ഀ 1 1ഀ 0ഀ 1 1ഀ 0ഀ 1 1ഀ 0ഀ 1ഀ 20 1ഀ 'ഀ 'ഀ minഀ .091ഀ 181ഀ -5.1-ഀ 4`ഀ 0ഀ 1ഀ 0ഀ 1 1ഀ 0 1ഀ 1 1ഀ 0ഀ 1ഀ 0ഀ 1ഀ Hot Rolled Steel Section Setsഀ Label Shape Desi n List Type Material Design Rules A in2 I in4 Izz in4 J in4ഀ Li Beam I W12X26 Wide Flange Beam A992 Typical 7.65 1 17.3 204 .3 1ഀ RISA-3D Version 5.0d [D:\Projects\5500\Roof Beam - RB116 - Bent.r3d] Page 3ഀ Company Monroe & Newell Engineers, Inc. Dec 14, 2005ഀ Designer Arthur Ashworth, PE 6:41 AMഀ Job Number : 5500.02 Roof Beam - RB116 - Bent Checked By:ഀ Envelope ASD Steel Code Checksഀ RISA-3D Version 5.Od [D:\Projects\5500\Roof Beam - RB116 - Bent.r3d] Page 4ഀ i(_,t,~ „e,)ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ z' 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 Page 1ഀ User: -0606238, Multi-Span Steel Beamഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8196 Beamsഀ Description Roof Beam - RB117ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ L Cantഀ Spanഀ R Cantഀ Spanഀ ftഀ 3.50ഀ 15.00ഀ 5.00ഀ Steel Sectionഀ wax10ഀ w8x10ഀ w8x10ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Lengthഀ ftഀ 3.50ഀ 4.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.075ഀ 0.075ഀ 0.075ഀ Live Loadഀ k/ftഀ 0.250ഀ 0.250ഀ 0.250ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 6.14ഀ 0.00ഀ @ X =ഀ ftഀ 0.00ഀ 7.10ഀ 0.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -1.99ഀ -4.06ഀ Max @ Right Endഀ k-ftഀ -1.99ഀ -4.06ഀ 0.00ഀ fb : Actualഀ psiഀ 3,059.6ഀ 9,442.3ഀ 6,244.1ഀ Fb : Allowableഀ psiഀ 30,000.0ഀ 29,492.2ഀ 27,331.5ഀ Bending OKഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 848.1ഀ 1,920.2ഀ 1,211.5ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 2.30ഀ 1.62ഀ Shear @ Rightഀ kഀ 1.14ഀ 2.58ഀ 0.00ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 0.79ഀ 0.97ഀ LL @ Leftഀ kഀ 0.00ഀ 2.64ഀ 3.23ഀ Total @ Leftഀ kഀ 0.00ഀ 3.44ഀ 4.20ഀ DL @ Rightഀ kഀ 0.79ഀ 0.97ഀ 0.00ഀ LL @ Rightഀ kഀ 2.64ഀ 3.23ഀ 0.00ഀ Total @ Rightഀ kഀ 3.44ഀ 4.20ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.162ഀ -0.250ഀ 0.148ഀ @ X =ഀ ftഀ 0.00ഀ 7.30ഀ 5.00ഀ Span/Deflection Ratioഀ 518.6ഀ 720.0ഀ 812.6ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 2.30ഀ 1.62ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -1.99ഀ -4.06ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.1620ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ _ J,ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 Page 1ഀ User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983.2003 ENERCALC Engineering Software _ 5500.ecw:8195 Beamsഀ Description Roof Beam - RB118ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ L Cantഀ Spanഀ Spanഀ ftഀ 3.50ഀ 5.00ഀ Steel Sectionഀ wsx10ഀ w8x10ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.50ഀ 5.00ഀ Loadsഀ -ഀ Used This Span ?ഀ =1ഀ Yesഀ Yesഀ k/ftഀ Dead Loadഀ 0.180ഀ 0.180ഀ .ഀ Live Load k/ftഀ 0.600ഀ 0.600ഀ Resultsഀ `ഀ Mmax @ Cntr k-ftഀ 0.00ഀ 0.63ഀ @ X = ftഀ 0.00ഀ 3.73ഀ Max @ Left End k-ftഀ 0.00ഀ -4.78ഀ Max @ Right End k-ftഀ -4.78ഀ 0.00ഀ fb : Actual psiഀ 7,343.1ഀ 7,343.1ഀ Fb : Allowable psiഀ , 30,000.0ഀ 27,331.5ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 2,035.3ഀ 2,166.2ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ E eactions & Deflectionsഀ Rഀ Shear @ Left kഀ 0.00ഀ 2.91ഀ Shear @ Right kഀ 2.73ഀ 0.99ഀ Reactions...ഀ ,ഀ DL @ Left kഀ 0.00ഀ 1.30ഀ LL @ Left kഀ 0.00ഀ 4.33ഀ Total @ Left kഀ 0.00ഀ 5.64ഀ DL @ Right kഀ 1.30ഀ 0.23ഀ LL @ Right kഀ 4.33ഀ 0.76ഀ Total @ Right kഀ 5.64ഀ 0.99ഀ Max. Deflection inഀ -0.055ഀ 0.004ഀ @ X = ftഀ 0.00ഀ 1.23ഀ Span/Deflection Ratioഀ 1,530.3ഀ 15,429.4ഀ Query Valuesഀ Location ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shear kഀ 0.00ഀ 2.91ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Moment k-ftഀ 0.00ഀ -4.78ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflection inഀ j -0.0549ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ a Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - R6119ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ L Cantഀ Spanഀ R Cantഀ Spanഀ ftഀ 3.50ഀ 6.00ഀ 2.00ഀ Steel Sectionഀ wlox12ഀ WlOX12ഀ WIox12ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Freeഀ Unbraced Lengthഀ ftഀ 3.50ഀ 4.00ഀ 2.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.195ഀ 0.195ഀ 0.195ഀ Live Loadഀ k/ftഀ 0.650ഀ 0.650ഀ 0.650ഀ Point #1 DLഀ kഀ 1.480ഀ LLഀ kഀ 4.950ഀ @ Xഀ ftഀ 2.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftiഀ 0.00ഀ 0.00ഀ 0.00ഀ @ X =ഀ ft Iഀ 0.00ഀ 0.00ഀ 2.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -5.18ഀ -14.55ഀ Max @ Right Endഀ k-ft iഀ -5.18ഀ -14.55ഀ 0.00ഀ fb : Actualഀ psiഀ 5,697.0ഀ 16,015.8ഀ 16,015.8ഀ Fb : Allowableഀ psiഀ 30,000.0ഀ 29,248.4ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ Bending OKഀ fv:Actualഀ psiഀ 1,577.1ഀ 2,184.9ഀ 4,330.0ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectiഀ onsഀ Shear @ Leftഀ kഀ 0.00ഀ 0.97ഀ 8.12ഀ Shear @ Rightഀ kഀ 2.96ഀ 4.10ഀ 6.43ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 0.91ഀ 2.81ഀ LL @ Leftഀ kഀ 0.00ഀ 3.02ഀ 9.40ഀ Total @ Leftഀ kഀ 0.00ഀ 3.93ഀ 12.22ഀ DL @ Rightഀ k1ഀ 0.91ഀ 2.81ഀ 0.00ഀ LL @ Rightഀ kഀ 3.02ഀ 9.40ഀ 0.00ഀ Total @ Rightഀ kഀ 3.93ഀ 12.22ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.084ഀ 0.034ഀ -0.080ഀ @ X =ഀ ft 1ഀ 0.00ഀ 3.36ഀ 2.00ഀ Span/Deflection Ratioഀ 995.4ഀ 2,127.1ഀ 599.5ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 0.97ഀ 8.12ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -5.18ഀ -14.55ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in 1ഀ -0.0844ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:39AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ Bഀ (c)1983-2003 ENERCALC Engineering Softwareഀ 5500.ecw:8195ഀ eamsഀ Description Roof Beam - RB120ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ _ഀ ഀ Descriptionഀ L Span R Spanഀ Spanഀ ft 15.00 8.00ഀ Steel Sectionഀ waxes waxesഀ End Fixityഀ Pin-Pin Pin-Pinഀ Unbraced Lengthഀ ft 5.00 5.00ഀ Loadsഀ Live Load Used This Span ? Yes Yesഀ Dead Loadഀ k/ft 0.240 0.120ഀ Live Loadഀ k/ft 0.800 0.400ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 19.89 0.00ഀ @ X =ഀ ftഀ 6.20 8.00ഀ Max @ Left Endഀ k-ftഀ l 0.00 -20.52ഀ 0ഀ 0ഀ Max @ Right Endഀ k-ftഀ i -20.52ഀ .ഀ 0ഀ fb : Actualഀ psiഀ 16,193.0 16,193.0ഀ Fb : Allowableഀ psiഀ 30,000.0 30,000.0ഀ Sending OK Bending OKഀ fv : Actualഀ psiഀ 4,897.0 2,481.2ഀ Fv : Allowableഀ psiഀ 20,000.0 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 6.43ഀ 4.65ഀ Shear @ Rightഀ kഀ 9.17ഀ 0.49ഀ Reactions...ഀ DL @ Leftഀ kഀ 1.48ഀ 3.19ഀ LL @ Leftഀ kഀ 4.95ഀ 10.63ഀ Total @ Leftഀ kഀ 6.43ഀ 13.81ഀ DL @ Rightഀ kഀ 3.19ഀ -0.11ഀ LL @ Rightഀ kഀ 10.63ഀ -0.37ഀ Total @ Rightഀ kഀ 13.81ഀ -0.49ഀ Max. Deflectionഀ inഀ -0.386ഀ 0.056ഀ @ X =ഀ ftഀ 6.80ഀ 3.09ഀ Span/Deflection Ratioഀ 466.1ഀ 1,727.7ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 6.43ഀ 4.65ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -20.52ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ t 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Roof Beam - RB121ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W14X22ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 18.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 4.00 ftഀ Trapezoidal Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1 DL @ Left 0.345ഀ LL @ Leftഀ 1.150 ST @, Leftഀ k/ft Start itഀ DL @ Righi 0.120ഀ LL @ Rightഀ 0.400 ST @ Righiഀ k/ft End ftഀ Summaryഀ Beam OKഀ - - """~'"'--~""'B 'ഀ Static Load Caseഀ Governs Stressഀ Using: W 14X22 section, Span =ഀ 18.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 4.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 41.953 k-ftഀ 79.750 k-ftഀ Max. Deflectionഀ -0.422 inഀ fb : Bending Stressഀ 17.360 ksiഀ 33.000 ksiഀ Length/DL Deflഀ 2,072.6 :1ഀ fb / Fbഀ 0.526 : 1ഀ Length/(DL+LL Defl)ഀ 512.4: 1ഀ Shearഀ 10.728 kഀ 63.204 kഀ fv : Shear Stressഀ 3.395 ksiഀ 20.000 ksiഀ fv / Fvഀ 0.170 : 1ഀ Force & Stress Summaryഀ « - These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+STഀ LL LL+STഀ Maximumഀ Onlyഀ @ Center @ Centerഀ @ Cants @ Cantsഀ Max. M + 41.95 k-ftഀ 10.36ഀ 41.95ഀ k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 10.73 kഀ 2.63ഀ 10.73ഀ kഀ Shear @ Right 7.80 kഀ 1.95ഀ 7.80ഀ kഀ Center Defl. -0.422 inഀ -0.104ഀ -0.422ഀ -0.422ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant DO 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 10.73ഀ 2.63ഀ 10.73ഀ 10.73ഀ kഀ Reaction @ Rt 7.80ഀ 1.95ഀ 7.80ഀ 7.80ഀ kഀ Fa calc'd per Eq. E2-1, K'Ur < Ccഀ I Beam Passes Table B5.1, Fb per Eq. Fഀ 1-1, Fb = 0.66 Fyഀ Section Properties W1 4X22ഀ Depthഀ Web Thickഀ Widthഀ Flange Thickഀ Areaഀ Rtഀ 13.740 inഀ 0.230 inഀ 5.000 inഀ 0.335 inഀ 6.49 in2ഀ 1.250 inഀ Weightഀ Ixxഀ lyyഀ Sxxഀ Syyഀ R-xxഀ R-yyഀ Zxഀ Zyഀ Kഀ 22.04 #/ftഀ 199.000 in4ഀ 7.000 in4ഀ 29.000 in3ഀ 2.800 in3ഀ 5.540 inഀ 1.040 inഀ Values for LRFD Design....ഀ 1 0.210 in4ഀ Cw 314.00 in6ഀ 33.200 in3ഀ 4.390 in3ഀ 0.735 inഀ L Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street; Suite 200 Dsgnr: Arthur Ashworth, PEഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5-8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB122ഀ vഀ Job # 5500.02ഀ Date: 6:39AM, 14 DEC 05ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress rvW-_ 50.00 ksi~ WLoad Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ a L Cantഀ Spanഀ Span ftഀ 5.00ഀ 18.00ഀ Steel Sectionഀ w14x22ഀ w14x22ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Length ftഀ 5.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ DL @ Left k/ftഀ 0.120ഀ DL @ Right k/ftഀ 0.270ഀ LL @ Left k/ftഀ 0.400ഀ LL @ Right k/ftഀ 0.900ഀ Start ftഀ End ftഀ 5.000ഀ 18.000ഀ Resultsഀ - - -ഀ Mmax @ Cntr k-ftഀ 0.00ഀ 22.53ഀ @ X = ftഀ 0.00ഀ 10.80ഀ Max @ Left End k-ft ~ഀ 0.00ഀ -4.33ഀ Max @ Right End k-ft'ഀ -4.33ഀ 0.00ഀ fb : Actual psiഀ 1,795.0ഀ 9,332.3ഀ Fb : Allowable psiഀ 29,568.6ഀ 29,568.6ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 411.4ഀ 2,145.2ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 3.75ഀ Shear @ Rightഀ kഀ 1.30ഀ 6.78ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 1.17ഀ LL @ Leftഀ kഀ 0.00ഀ 3.89ഀ Total @ Leftഀ kഀ 0.00ഀ 5.05ഀ DL @ Rightഀ k!ഀ 1.17ഀ 1.56ഀ LL @ Rightഀ k,ഀ 3.89ഀ 5.21ഀ Total @ Rightഀ k!ഀ 5.05ഀ 6.78ഀ Max. Deflectionഀ inഀ 0.149ഀ -0.214ഀ @ X =ഀ ftഀ 0.00ഀ 9.48ഀ Span/Deflection Ratioഀ 804.5ഀ 1,009.1ഀ Query Valuesഀ Locationഀ ft lഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 3.75ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-1ഀ 0.00ഀ -4.33ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.1492ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ rഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ .ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:39AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ (c)1983.2003 ENERCALCഀ Engineering Softwareഀ 5500.ecw:8195 Beams -ഀ Descriptionഀ Roof Beam - 46123ഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ L Cantഀ Spanഀ Spanഀ ftഀ 3.00ഀ 8.00ഀ Steel Sectionഀ waxesഀ wsxlsഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yes Yesഀ Dead Load k/ftഀ 0.120 0.120ഀ Live Load k/ftഀ 0.400 0.400ഀ Point #1 DL kഀ 1.000ഀ LL kഀ 2.500ഀ @X ftഀ Mmax @ Cntrഀ k-ftഀ !ഀ 0.00ഀ 0.22ഀ @ X =ഀ ftഀ ;ഀ 0.00ഀ 7.09ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -12.84ഀ Max @ Right Endഀ k-ftഀ -12.84ഀ 0.00ഀ fb : Actualഀ psiഀ 10,130.7ഀ 10,130.7ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 30,000.0ഀ Bending OKഀ Bending OKഀ fv:Actualഀ psiഀ 2,702.7ഀ 1,968.3ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectiഀ onsഀ Shear @ Leftഀ kഀ 0.00ഀ 3.68ഀ Shear @ Rightഀ k :ഀ 5.06ഀ 0.48ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 2.28ഀ LL @ Leftഀ kഀ 0.00ഀ 6.46ഀ Total @ Leftഀ kഀ 0.00ഀ 8.74ഀ DL @ Rightഀ kഀ 2.28ഀ 0.04ഀ LL @ Rightഀ kഀ 6.46ഀ 0.44ഀ Total @ Rightഀ kഀ 8.74ഀ 0.48ഀ Max. Deflectionഀ inഀ -0.102ഀ 0.026ഀ @ X =ഀ ftഀ 0.00ഀ 2.72ഀ Span/Deflection Ratioഀ 706.5ഀ 3,744.2ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 0.00ഀ 3.68ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ 0.00ഀ -12.84ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.1019ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ ഀ 1701 Wynkoop Street, Suite 200 Ds9nr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ ഀ Denver, CO 80202 Description : Lodge Expansionഀ ` 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ 580006ഀ KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 1ഀ 3-2003 ENERCALC Engineering Software 5500.ecw:8195 Beams 11ഀ Description Roof Beam - RB124ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W8X10ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 8.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 4.00 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ DL 0.120ഀ k/ftഀ LL 0.400ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Location 8.000ഀ ftഀ >ummaryഀ Beam OKഀ Static Load Caseഀ Governs Stressഀ Using: W8X10 section, Span = 8.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 4.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 4.240 k-ftഀ 19.194 k-ftഀ Max. Deflectionഀ -0.055 inഀ fb : Bending Stress 6.515 ksiഀ 29.492 ksiഀ Length/DL Deflഀ 7,154.3: 1ഀ fb / Fb 0.221 : 1ഀ Length/(DL+LL Defl)ഀ 1,755.4: 1ഀ Shear 2.120 kഀ 26.826 kഀ fv : Shear Stress 1.581 ksiഀ 20.000 ksiഀ fv / Fv 0.079 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+ST LL LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cants @ Cantsഀ Max. M + 4.24 k-ftഀ 1.04ഀ 4.24 k-ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 2.12 kഀ 0.52ഀ 2.12 kഀ Shear @ Right 2.12 kഀ 0.52ഀ 2.12 kഀ Center Defl. -0.055 inഀ -0.013ഀ -0.055ഀ -0.055ഀ 0.000ഀ 0.000 inഀ Left Cant DefI 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query DO @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 2.12ഀ 0.52ഀ 2.12ഀ 2.12ഀ kഀ Reaction @ Rt 2.12ഀ 0.52ഀ 2.12ഀ 2.12ഀ kഀ Fa calc'd per Eq. E2-2, K'L/r > Ccഀ I Beam, Maior Axis, (102,000' Cb / Fy)A.ഀ 5 UrT (510,ഀ 000' Cb / Fy)A.5ഀ , Fb per Eq. F1-6ഀ r43 k-5bഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ z 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Page 2ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Software SSOO.ecw:8195 Beamsഀ Description Roof Beam - RB124ഀ Section Propertiesഀ W8X10ഀ Depthഀ 7.890 inഀ Weightഀ 10.05 #/ftഀ Web Thickഀ 0.170 inഀ Ixxഀ 30.800 in4ഀ Widthഀ 3.940 inഀ lyyഀ 2.090 in4ഀ Flange Thickഀ 0.205 inഀ Sxxഀ 7.810 in3ഀ Areaഀ 2.96 in2ഀ Syyഀ 1.060 in3ഀ Rtഀ 0.990 inഀ R-xxഀ 3.220 inഀ Values for LRFD Design....ഀ R-yyഀ 0.841 inഀ Jഀ 0.040 in4ഀ Zxഀ 8.870 in3ഀ Cwഀ 30.90 in6ഀ Zyഀ 1.660 in3ഀ Kഀ 0.505 inഀ 'K-Sr 13 "iഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:39AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ ഀ Page 1ഀ ~55510001.ecw:819556eamsഀ c)1983.2003 ENERCALC Engineering Softwaeഀ (ഀ -ഀ Descriptionഀ Roof Beam - RB125ഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ General Informationഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ L Cantഀ L Spanഀ R Spanഀ Spanഀ ftഀ 100ഀ 16.00ഀ 11.00ഀ Steel Sectionഀ W32X26ഀ W12X26ഀ W12x26ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Pin-Pinഀ thഀ Unbraced Lenഀ ftഀ 3.00ഀ 5.00ഀ 5.00ഀ gഀ Loadsഀ mഀ -ഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.360ഀ 0.285ഀ 0.150ഀ Live Loadഀ k/ftഀ 1.200ഀ 0.950ഀ 0.500ഀ Point #1 DLഀ kഀ 1.910ഀ LLഀ kഀ 6.250ഀ @ Xഀ ftഀ 10.000ഀ Resultsഀ Mmax @ Cntrഀ k -ftഀ 0.00ഀ 40.85ഀ 0.00ഀ @ X =ഀ ftഀ 0.00.ഀ 8.85ഀ 11.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -7.02ഀ -40.08ഀ Max @ Right Endഀ k-ftഀ -7.02ഀ -40.08ഀ 0.00ഀ fb : Actualഀ psiഀ 2,523.1ഀ 14,681.8ഀ 14,404.5ഀ Fb : Allowableഀ psiഀ , 33,000.0ഀ 33,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ Bending OKഀ fv:Actualഀ psiഀ 1,665.1ഀ 6,064.9ഀ 2,568.3ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 10.87ഀ 7.22ഀ Shear @ Rightഀ kഀ 4.68ഀ 17.05ഀ 0.07ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 3.60ഀ 5.62ഀ LL @ Leftഀ kഀ 0.00ഀ 11.96ഀ 18.64ഀ Total @ Leftഀ kഀ 0.00ഀ 15.55ഀ 24.26ഀ DL @ Rightഀ kഀ 3.60ഀ 5.62ഀ -0.02ഀ LL @ Rightഀ kഀ 11.96ഀ 18.64ഀ -0.05ഀ Total @ Rightഀ kഀ 15.55ഀ 24.26ഀ -0.07ഀ Max. Deflectionഀ inഀ 0.151ഀ -0.274ഀ 0.056ഀ @ X =ഀ ftഀ 0.00ഀ 7.79ഀ 4.11ഀ Span/Deflection Ratioഀ 476.2ഀ 701.2ഀ 2,340.0ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 0ഀ 00ഀ Shearഀ kഀ 0.00ഀ 10.87ഀ 02ഀ 7ഀ 7.22ഀ 08ഀ -40ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ Momentഀ Max. Deflectionഀ k-ftഀ inഀ 0.00ഀ 0.1512ഀ .ഀ -ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ k '_ft) 14-vഀ t Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:39AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beam 5500.ecw:8195 Beamsഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Roof Beam - RB126ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Spans Considered Continuous Over Supportsഀ 1.00ഀ Span Informationഀ BEEN,ഀ Descriptionഀ L Cantഀ Spanഀ Spanഀ ftഀ 100ഀ 15.00ഀ Steel Sectionഀ w8x18ഀ wsxisഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ? Iഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.180ഀ Live Loadഀ k/ftഀ 0.600ഀ DL @ Leftഀ k/ftഀ 0.270ഀ DL @ Rightഀ k/ftഀ LL @ Leftഀ k/ft ;ഀ 0.900ഀ LL @ Rightഀ k/ftഀ Startഀ ftഀ Endഀ ftഀ 15.000ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 14.90ഀ @ X =ഀ ftഀ 0.00ഀ 6.70ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -3.51ഀ Max @ Right Endഀ k-ftഀ -3.51ഀ 0.00ഀ fb : Actualഀ psiഀ 2,769.4ഀ 11,758.3ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 30,000.0ഀ Bending OKഀ 'Bending OKഀ fv : Actualഀ psiഀ 1,249.9ഀ 3,249.7ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ Shear @ Rightഀ kഀ Reactions...ഀ DL @ Leftഀ kഀ LL @ Leftഀ kഀ Total @ Leftഀ kഀ DL @ Rightഀ kഀ LL @ Rightഀ kഀ Total @ Rightഀ kഀ Max. Deflectionഀ inഀ @X=ഀ ftഀ Span/Deflection Ratioഀ Query Valuesഀ Locationഀ ftഀ Shearഀ kഀ Momentഀ k-ftഀ Max. Deflectionഀ inഀ 0.00 6.08ഀ 2.34 2.69ഀ 0.00 1.94ഀ 0.00 6.48ഀ 0.00 8.42ഀ 1.94 0.62ഀ 6.48 2.07ഀ 8.42 2.69ഀ 0.194 -0.324ഀ 0.00 7.30ഀ 370.9 555.7ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ 6.08ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ -3.51ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.1941ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:39AM, 14 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ `ഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ 5500.ecw:8195 Beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Descriptionഀ Roof Beam - RB127ഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Im"giഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cantഀ Spanഀ Spanഀ ftഀ 3.00ഀ 10.00ഀ Steel Sectionഀ W10x12ഀ wiox12ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ Unbraced Lengthഀ ftഀ 3.00ഀ 5.00ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.360ഀ Live Load k/ftഀ 1.200ഀ Dead Load k/ftഀ 0.360ഀ Live Load k/ftഀ 1.200ഀ Start ftഀ End ftഀ 3.000ഀ 4.000ഀ DL @ Left k/ftഀ 0.360ഀ DL @ Right k/ftഀ LL @ Left k/ftഀ 1.200ഀ LL @ Right k/ftഀ Start ftഀ 4.000ഀ End ftഀ 10.000ഀ Resultsഀ _ഀ k-ftഀ Mmax @ Cntrഀ 0.00ഀ 11.36ഀ @ X = ftഀ 0.00ഀ 4.93ഀ Max @ Left End k ftഀ 0.00ഀ -7.02ഀ Max @ Right End k-ft!ഀ -7.02ഀ 0.00ഀ fb : Actual psiഀ 7,727.2ഀ 12,501.6ഀ Fb : Allowable psiഀ 30,000.0ഀ 26,950.6ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 2,495.6ഀ 4,034.6ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 0.00ഀ 7.57ഀ Shear @ Right kഀ 4.68ഀ 3.35ഀ Reactions...ഀ DL @ Left kഀ 0.00ഀ 2.83ഀ LL @ Left kഀ 0.00ഀ 9.42ഀ Total @ Left kഀ 0.00ഀ 12.25ഀ DL @ Right kഀ 2.83ഀ 0.77ഀ LL @ Right kഀ 9.42ഀ 2.58ഀ Total @ Right kഀ 12.25ഀ 3.35ഀ Max. Deflection inഀ 0.075ഀ -0.121ഀ @ X = ftഀ 0.00ഀ 5.07ഀ Span/Deflection Ratioഀ 964.0ഀ 992.3ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ U.UUഀ U.UUഀ 00ഀ 0ഀ U.UUഀ 0ഀ 00ഀ V.u~ഀ 00ഀ 0ഀ Shearഀ kഀ 0.00ഀ 7.57ഀ 02ഀ 7ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ Momentഀ Max. Deflectionഀ k-ftഀ inഀ 0.00ഀ 0.0747ഀ .ഀ -ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ C' 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Ver5.8.0, 1-Dec-2003ഀ CALC Engineering Softwareഀ Description Floor Beam - FB1ഀ Composite Steel Beamഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Nameഀ W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 22.500 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab Both Sidesഀ Dead Loadsഀ (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1ഀ 0.350 k/ftഀ #1 k ftഀ Live Loadsഀ (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ aഀ Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ Summary OK Shored & Unshoredഀ Using: W12X14, Span = 22.50ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 25,842.7 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 18,584.9 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 4,081.2 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) 'Actual =ഀ 33,537.9 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual =ഀ 344.4 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MIIഀ ) / Ssഀ 44,104.5ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top' n)ഀ 595.3ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 5 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3 studs Vh @ 100% 104.00k Vh : Used 61.98 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 3.750 It , Useഀ 2 studsഀ Zone 2 fromഀ 3.750 ftഀ toഀ 7.500 ft , Useഀ 2 studsഀ Zone 3 fromഀ 7.500 ftഀ toഀ 11.250 ft , Useഀ 1 studsഀ Zone 4 fromഀ 11.250 ftഀ toഀ 15.000 ft , Useഀ 1 studsഀ Zone 5 fromഀ 15.000 ftഀ toഀ 18.750 It , Useഀ 2 studsഀ Zone 6 fromഀ 18.750 ftഀ toഀ 22.500 ft , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Composite Steel Beamഀ User: KW-0606238, Ver 5.8.0, 1 -Dec-2003ഀ Page 2ഀ 5500.ecw:8182 beamsഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Descriptionഀ Floor Beam - FB1ഀ Deflectionsഀ fഀ I :Transformedഀ 383.25 in4ഀ I : Effective 316.07in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.229 inഀ (after shores removed)ഀ 0.817 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.314 inഀ 0.314 inഀ Total Uncured Deflectionഀ 0.229 inഀ L / 1179.2ഀ 0.817 in L / 330.6ഀ Composite Deflectionഀ 0.544 inഀ L / 496.7ഀ 1.131 in L / 238.7ഀ ~i Reactionsഀ Load Combinations... bഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 4.10kഀ 4.10 kഀ Compositeഀ 5.62 kഀ 5.62 kഀ Max DL + LLഀ 9.72 kഀ 9.72 kഀ Analysis Valuesഀ Maximum Momentsഀ Dead Load Aloneഀ Dead + Constഀ Live Load Onlyഀ Dead + Liveഀ Support Shearsഀ Shear @ Leftഀ Shear @ Rightഀ 23.04 k-ftഀ Fb : Allow 33.00 psiഀ 23.04 k-ftഀ n : Strength 8.60ഀ 31.64 k-ftഀ n : Deflection 8.51ഀ 54.68 k-ftഀ 9.72 kഀ 9.72 kഀ Effective Flange Width...ഀ Based on Beam Span 5.625 Itഀ Based on Beam Spacing 5.000 ftഀ Effective Width 5.000 ftഀ Section Propertiesഀ Section Nameഀ Depthഀ Widthഀ Flange Thickഀ Web Thickഀ Areaഀ Weightഀ I-steelഀ S steel : topഀ S steel : bottomഀ W12X14ഀ 11.910 inഀ 3.970 inഀ 0.225 inഀ 0.200 inഀ 4.160 in2ഀ 14.130 #/ftഀ 88.60 in4ഀ 14.88 in3ഀ 14.88 in3ഀ Ixx : Steel Sectionഀ I transformedഀ Strans : topഀ Strans : botഀ Strans : eff @ botഀ n`Strans : Ef @ topഀ X-X Axis from Botഀ Vh @ 100%ഀ 88.60 in4ഀ 382.59 in4ഀ 128.18 in3ഀ 28.50 in3ഀ 25.39 in3ഀ 880.2 in3ഀ 13.43 inഀ 104.00 kഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ 1701 Wynkoop Street, Suite 200 Descriptionഀ Denver, CO 80202 Lodge Expansionഀ 303.623.4927ഀ Scopeഀ ;i Fax: 303.623.6602ഀ Rev: 580001 Page 1ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beam 5500.ecw:8182 beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB2ഀ -ഀ Design Inputഀ Code Ref: AI stഀ Section Nameഀ W10X12ഀ Fy 50.00 ksiഀ Beam Spanഀ 14.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ # 1 0.350 k/ftഀ Point Loads...ഀ # 1ഀ k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ftഀ # 1ഀ k ftഀ Summaryഀ OK Shored & Unshored.ഀ Using: W10X12, Span = 14.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 15,314.6 psiഀ Allowable =ഀ 33,3310 psi OKഀ Unshored DL Stress Actual = 9,763.1 psiഀ Allowable =ഀ 33,333.0 psi OKഀ Actual Shear Stress Actual = 3,217.7 psiഀ Allowable =ഀ 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 18,646.1 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 213.0 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 23,247.2 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + Mil) / (Strans:top' n) 367.2 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studsഀ Total req'd 1/2 Spanഀ Zone 1 fromഀ Zone 2 fromഀ Zone 3 fromഀ Zone 4 fromഀ Zone 5 fromഀ Zone 6 fromഀ 2 per 1/2 beam spanഀ Stud Capacityഀ 12.40 kഀ V'h : min 22.13 kഀ 2studsഀ Vh @ 100%ഀ 88.50kഀ Vh : Used 24.79 kഀ 0.000 ftഀ toഀ 2.333 ft , Useഀ 1 studsഀ 2.333 ftഀ toഀ 4.667 ft , Useഀ 1 studsഀ 4.6667 ftഀ toഀ 7.000 ft , Useഀ 0 studsഀ 7.000 ftഀ toഀ 9.333 ft , Useഀ 0 studsഀ 9.333 ftഀ toഀ 11.667ft , Useഀ 1 studsഀ 11.667 ftഀ toഀ 14.000ft , Useഀ 1 studsഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 200ഀ iഀ Sഀ Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ teഀ uഀ 1701 Wynkoop Street,ഀ iഀ iഀ ptഀ Descrഀ on : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ 623.6602ഀ Fax: 303ഀ .ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 COt71(JO$Ite Sഀ teel Bec'3111ഀ Page 2ഀ 5500.ecw:8,82 beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB2ഀ Deflectionsഀ I : Transformed 244.80 in4ഀ I : Effective 154.Kin4ഀ Shoredഀ Unshoredഀ Before 75 % Curing 0.070 in (after shores removed) 0.200 inഀ Construction Loads Only 0.000 inഀ 0.000 inഀ After 75% Curing 0.096 inഀ 0.096 inഀ Total Uncured Deflection 0.070 in L / 2412.8ഀ 0.200 in L / 838.1ഀ Composite Deflection 0.166 in L/1012-9ഀ 0.297 in L / 566.4ഀ Reactionsഀ NEW=ഀ Load Combinations... @ Leftഀ @ Rightഀ Dead + Constuction 2.53 kഀ 2.53 kഀ Composite 3.50 kഀ 3.50 kഀ Max DL + LL 6.03 kഀ 6.03 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Alone 8.87 k-ft Fb : Allowഀ 33.00 psi Based on Beam Spanഀ 3.500 ftഀ Dead + Const 8.87 k-ft n : Strengthഀ 8.60 Based on Beam Spacingഀ 5.000 ftഀ Live Load Only 12.25 k-ft n : Deflectionഀ 8.51ഀ Dead + Live 21.12 k-ftഀ Effective Widthഀ 3.500 ftഀ Support Shearsഀ Shear @ Left 6.03 kഀ Shear @ Right 6.03 kഀ section Propertiesഀ Section Name W10X12ഀ Depth 9.870 in Ixx : Steel Sectionഀ 53.80 in4ഀ Width 3.960 in I transformedഀ 244.31 in4ഀ Flange Thick 0.210 in Strans : topഀ 80.26 in3ഀ Web Thick 0.190 in Strans : botഀ 21.57 in3ഀ Area 3.540 in2 Strans : eff @ botഀ 16.55 in3ഀ Weight 12.024 #/ft n`Strans : Ef @ topഀ 409.4 in3ഀ I-steel 53.80 in4 X-X Axis from Botഀ 11.33 inഀ S steel : top 10.90 in3 Vh @ 100%ഀ 88.50 kഀ S steel : bottom 10.90 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1-11ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Rev: 580001 pഀ User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB3ഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Inഀ Section Nameഀ Beam Spanഀ Beam Spacingഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFFA bUUUഀ W12X26 Fy 50.00 ksiഀ 22.500 ft f'c 3,500.00 psiഀ 5.000 ft Concrete Density 145.00 pcfഀ Slab Thickness 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Height 1.500 inഀ Stud Height 3.000 inഀ Rib Spacing 6.000 inഀ Beam Weight Added Internallyഀ Rib Width 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ 77-ഀ Point Loads...ഀ # 1 0.350 k/ftഀ # 1 5.170 k 4.000ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ftഀ # 1 10.100 k 4.000 ftഀ OK Shored & Unshoredഀ Using: W 12X26, Span = 22.50ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spec= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beamഀ Actual = 24,114.9 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stressഀ Actual = 12,671.4 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stressഀ Actual = 7,973.4 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans)ഀ 'Actual = 27,396.3 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top)ഀ Actual = 442.0 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stressഀ Check : (Mdl + MII) / Ssഀ 32,411.3ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top " n)ഀ 723.8ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 5 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 47.81 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 191.25k Vh : Used 61.98 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.700 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 2.700 ftഀ toഀ 5.400 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 5.400 ftഀ toഀ 8.100 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 8.100 ftഀ toഀ 12.900 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 12.900 ftഀ toഀ 17.700 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 17.700 ftഀ toഀ 22.500 ftഀ , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 'ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver 5ഀ .8.0, 1-Dec-2003 Composite Steel Beamഀ Page 2ഀ 5500.ecw:8182 beamsഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Descriptionഀ Floor Beam - FB3ഀ Deflectionsഀ I : Transformedഀ 686.16 in4ഀ Shoredഀ Before 75 % Curingഀ 0.235 in (after shores removed)ഀ Construction Loads Onlyഀ 0.000 inഀ After 75% Curingഀ 0.361 inഀ Total Uncured Deflectionഀ 0.235 in L/1150.2ഀ Composite Deflectionഀ 0.596 in L / 452.8ഀ I : Effectiveഀ Unshoredഀ 0.551 inഀ 0.000 inഀ 0.361 inഀ 0.551 inഀ 0.912 inഀ L / 490.4ഀ L / 296.0ഀ n4ഀ Reactionsഀ _ W-ഀ Load Combinations...ഀ Dead + Constuctionഀ Compositeഀ Max DL + LLഀ - -:_W_ .ഀ ;ഀ @ Leftഀ @ Rightഀ 8.48 kഀ 5.15 kഀ 13.93kഀ 7.42 kഀ 22.41 kഀ 12.57 kഀ Analysis Valuesഀ Maximum Momentsഀ Dead Load Aloneഀ 35.26 k-ft Fb : Allowഀ Dead + Constഀ 35.26 k-ft n : Strengthഀ Live Load Onlyഀ 55.06 k-ft n : Deflectionഀ Dead + Liveഀ 90.18 k-ftഀ Support Shearsഀ Shear @ Leftഀ 22.41 kഀ Shear @ Rightഀ 12.57 kഀ Effective Flange Width...ഀ 33.00 psi Based on Beam Span 5.625 ftഀ 8.60 Based on Beam Spacing 5.000 ftഀ 8.51ഀ Effective Width 5.000 ftഀ Section Propertiesഀ Section Nameഀ W12X26ഀ Depthഀ 12.220 inഀ Ixx : Steel Sectionഀ 204.00 in4ഀ Widthഀ 6.490 inഀ I transformedഀ 684.65 in4ഀ Flange Thickഀ 0.380 inഀ Strans : topഀ 173.84 in3ഀ Web Thickഀ 0.230 inഀ Strans : botഀ 53.57 in3ഀ Areaഀ 7.650 in2ഀ Strains : eff @ botഀ 44.87 in3ഀ Weightഀ 25.985 #/ftഀ n'Strans : Ef @ topഀ 974.7 in3ഀ I-steelഀ 204.00 in4ഀ X-X Axis from Botഀ 12.78 inഀ S steel : topഀ 33.39 in3ഀ Vh @ 100%ഀ 191.25 kഀ S steel : bottomഀ 33.39 in3ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ "ഀ 303.623.4927ഀ Scope:ഀ °iഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ ecw:8182 beamsഀ 5500ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ .ഀ Descriptionഀ Floor Beam - FB4 - Non compഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.350ഀ 0.350ഀ Live Load k/ftഀ 0.500ഀ 0.500ഀ Point #1 DL kഀ 8.310ഀ 26.520ഀ LL kഀ 2.230ഀ 23.070ഀ @ X ftഀ 4.000ഀ 2.500ഀ Resultsഀ Mmax @ Cntr k-ftഀ 43.53ഀ 0.00ഀ @ X = . ftഀ 4.05ഀ 0.00ഀ Max @ Left End k-ft !ഀ ~ഀ 0:00ഀ -126.63ഀ 0ഀ 00ഀ Max @ Right End k-ftഀ -126.63ഀ .ഀ fb : Actual psiഀ 24,249.3ഀ 24,249.3ഀ Fb : Allowable psiഀ 33,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ fv : Actual psiഀ 4,095.8ഀ 12,412.7ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ Shear @ Rightഀ kഀ Reactions...ഀ DL @ Leftഀ kഀ LL @ Leftഀ kഀ Total @ Leftഀ kഀ DL @ Rightഀ kഀ LL @ Rightഀ kഀ Total @ Rightഀ kഀ Max. Deflectionഀ inഀ @ X=ഀ ftഀ Span/Deflection Ratioഀ 12.60ഀ 17.06ഀ 7.77ഀ 4.83ഀ 12.60ഀ 35.81ഀ 32.97ഀ 68.78ഀ 0.102ഀ 18.30ഀ 2,640.6ഀ 51.71ഀ 49.59ഀ 35.81ഀ 32.97ഀ 68.78ഀ 0.00ഀ 0.00ഀ 0.00ഀ -0.173ഀ 2.50ഀ 347.6ഀ M _ -ഀ Query Valuesഀ j - -ഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 12.60ഀ 51.71ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ft Iഀ -0.00ഀ -126.63ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in,ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003ഀ Multi-Span Steel Beamഀ Page 1ഀ 5500.ecw:8182 beams ,ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - 1`135 - Non compഀ IGeneral Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksiഀ Load Duration Factorഀ 1.00ഀ Spans Considered Continuous Over Supportsഀ an Informationഀ Descriptionഀ Spanഀ Cantഀ Span ftഀ 22.50ഀ 2.50ഀ Steel Sectionഀ W14X43ഀ W14X43ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Length ftഀ 0.50ഀ 0.20ഀ Lഀ oadsഀ Eഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Load k/ftഀ 0.350ഀ 0.350ഀ Live Load k/ftഀ 0.500ഀ 0.500ഀ Point #1 DL kഀ 14.670ഀ 7.530ഀ LL kഀ 33.790ഀ 6.690ഀ @ X ftഀ 4.000ഀ 2.500ഀ Resultsഀ Mmax @ Cntr k-ftഀ 183.83ഀ 0.00ഀ @ X = ftഀ 4.05ഀ 0.00ഀ Max @ Left End k-ftഀ 0.00ഀ -38.21ഀ Max @ Right End k-ftഀ -38.21ഀ 0-00ഀ fb : Actual psiഀ 35,202.3ഀ 7,316.3ഀ Fb : Allowable psiഀ 33,000.0ഀ 33,000.0ഀ overstressഀ Sending OKഀ fv : Actual psiഀ 11,451.2ഀ 3,923.1ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left kഀ 47.71ഀ 16.34ഀ Shear @ Right kഀ 19.88ഀ 14.22ഀ Reactions...ഀ DL @ Left kഀ 15.11ഀ 15.84ഀ LL @ Left kഀ 32.60ഀ 20.38ഀ Total @ Left kഀ 47.71ഀ 36.22ഀ DL @ Right kഀ 15.84ഀ 0.00ഀ LL @ Right kഀ 20.38ഀ 0.00ഀ Total @ Right kഀ 36.22ഀ 0.00ഀ Max. Deflection inഀ -1.064ഀ 0.272ഀ @ X = ftഀ 9.90ഀ 2.50ഀ Span/Deflection Ratioഀ 253.8ഀ 220.5ഀ Query Valuesഀ Location ftഀ 0.00ഀ 0.00 0.00 0.00ഀ 0.00 0.00 0.00 0.00ഀ Shear kഀ 47.71ഀ 16.34 0.00 0.00ഀ 0.00 0.00 0.00 0.00ഀ Moment k-ftഀ -0.00ഀ -38.21 0.00 0.00ഀ 0.00 0.00 0.00 0.00ഀ Max. Deflection inഀ 0.0000ഀ 0.0000 0.0000 0.0000ഀ 0.0000 0.0000 0.0000 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ }ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.ഀ 1111ഀ 0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ ecw:8182 beamsഀ 5500ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ .ഀ Description Floor Beam - FB6 - Non compഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Spanഀ Cantഀ Spanഀ ftഀ 22.50ഀ 2.50ഀ Steel Sectionഀ W14X30ഀ W14x30ഀ End Fixityഀ Pin-Pinഀ Pin-Freeഀ Unbraced Lengthഀ ftഀ 0.50ഀ 0.20ഀ Loadsഀ Live Load Used This Span ?ഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.350ഀ 0.350ഀ Live Loadഀ k/ftഀ 0.500ഀ 0.500ഀ Point #1 DLഀ kഀ 10.810ഀ 11.250ഀ LLഀ kഀ 15.700ഀ 9.770ഀ @ Xഀ ftഀ 4.000ഀ 2.500ഀ Resultsഀ Mmax @ Cntrഀ k-ftഀ ~ഀ 108.77ഀ 0.00ഀ @ X=ഀ ftഀ 4.05ഀ 0.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -55.21ഀ Max @ Right Endഀ k-ft iഀ -55.21ഀ 0.00ഀ fb : Actualഀ psiഀ 31,039.5ഀ 15,753.7ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 7,735.5ഀ 6,1918ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Left aഀ kഀ 28.91ഀ 23.14ഀ Shear @ Rightഀ kഀ 16.73ഀ 21.02ഀ Reactions...ഀ DL @ Leftഀ kഀ 11.53ഀ 19.28ഀ LL @ Leftഀ kഀ 17.38ഀ 20.59ഀ Total @ Leftഀ kഀ 28.91ഀ 39.87ഀ DL @ Rightഀ kഀ 19.28ഀ 0.00 .ഀ LL @ Rightഀ kഀ 20.59ഀ 0.00ഀ Total @ Rightഀ kഀ 39.87ഀ 0.00ഀ Max. Deflectionഀ inഀ -0.905ഀ 0.169ഀ @ X =ഀ ftഀ 9.60ഀ 2.50ഀ Span/Deflection Ratioഀ 298.4ഀ 354.9ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ kഀ 28.91ഀ 23.14ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ft 'sഀ -0.00ഀ -55.21ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in,ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Descriptionഀ 5.8.0, 1-Dec-2003 Composite Steel Beamഀ C Engineering Softwareഀ Floor Beam - FB7ഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W1 2X22 Fy 50.00 ksiഀ Beam Span 22.500 ft f'c 3,500.00 psiഀ Beam Spacing 5.000 ft Concrete Density 1145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Deck Rib Heightഀ 1.500 inഀ Rib Spacingഀ 6.000 inഀ Rib Widthഀ 1.750 inഀ Rib Orientationഀ Perpendicularഀ Beam Locationഀ Slab One Sideഀ Stud Diameter 0.750 inഀ Stud Height 3.000 inഀ Beam Weight Added Internallyഀ Using Partial Composite Actionഀ Elastic Modulus 29,000.00 ksiഀ I Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.210 k/ft # 1 4.640 k 7.000ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.300 k/ft # 1 6.500 k 7.000 Itഀ Summary OK Shored & Unshoredഀ Using: W 12X22, Span = 22,50ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 28,895.3 psi Allowable = 33,333.0 psi OKഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 33.47 kഀ Total req'd 1/2 Span 3 studs Vh @ 100% 133.88k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.350 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 2.350 Itഀ toഀ 4.700 Itഀ , Useഀ 2 studsഀ Zone 3 fromഀ 4.700 ftഀ toഀ 7.050 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 7.050 ftഀ toഀ 12.200 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 12.200 Itഀ toഀ 17.350 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 17.350 ftഀ toഀ 22.500 ftഀ , Useഀ 1 studsഀ Unshored DL Stress Actual = 16,542.0 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual = 4,267.7 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 33,203.3 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual = 665.0 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 39,070.1ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top' n)ഀ 1,153.4ഀ 1,575.0 psiഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ w: 580001ഀ er: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ 1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB7ഀ Page 2ഀ 5500.ecw:8182 beamsഀ Deflectionsഀ I : Transformedഀ 500.74 in4ഀ I : Effective 337.7Cin4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.295 in (after shores removed)ഀ 0.639 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.399 inഀ 0.399 inഀ Total Uncured Deflectionഀ 0.295 in L / 914.1ഀ 0.639 in L / 422.3ഀ Composite Deflectionഀ 0.695 in L / 388.6ഀ 1.039 in L / 260.0ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 5.81 kഀ 4.05 kഀ Compositeഀ 7.85 kഀ 5.40 kഀ Max DL + LLഀ 13.66 kഀ 9.45 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 34.94 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.812 ftഀ Dead + Constഀ 34.94 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 2.500 ftഀ Live Load Onlyഀ 47.58 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 82.52 k-ftഀ Effective Width 2.500 ftഀ Support Shearsഀ Shear @ Leftഀ 13.66 kഀ Shear @ Rightഀ 9.45 kഀ Section Propertiesഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 499.27 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 99.84 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 42.28 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 34.27 in3ഀ Weightഀ 22.011 9/ftഀ n'Strans : Ef @ topഀ 555.6 in3ഀ ksteelഀ 156.00 in4ഀ X-X Axis from Botഀ 11.81 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 133.88 kഀ S steel : bottomഀ 25.35 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ y~Fax: 303.623.6602ഀ Composite Steel Beamഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Descriptionഀ Floor Beam - FB8ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name ^ W10X12ഀ Fy 50.00 ksiഀ Beam Spanഀ 9.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Bothഀ Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.350 k/ftഀ #1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ Qa,ഀ Summary OK Shored & Unshoredഀ Using: W10X12, Span = 9.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spec= 6.00in, Rib Width= 1.75in w/ Slab Bഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 6,483.8 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 4,034.8 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 2,068.5 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual =ഀ 7,795.6 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual =ഀ 116.2 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MII)ഀ / Ssഀ 9,607.3ഀ 38,000.0 psiഀ Shored Concrete Stress Check. ...(Mdl + MII) /ഀ (Strans(top " n)ഀ 200.4ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 2 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 22.13 kഀ Total req'd 112 Span 2studs Vh @ 100% 88.50k Vh : Used 24.79 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.500 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 1.500 ftഀ toഀ 3.000 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 3.000 ftഀ toഀ 4.500 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 4.500 ftഀ toഀ 6.000 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 6.000 ftഀ toഀ 7.500 ftഀ , Useഀ 1 studsഀ Zone 6fromഀ 7.500 ftഀ toഀ 9.000ftഀ , Useഀ 1 studsഀ i \ഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ 33-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB8ഀ Composite Steel Beamഀ - -ഀ Page 2ഀ 5500.ecw:8182 beamsഀ Deflectionsഀ I : Transformedഀ 223.42 in4ഀ I : Effective 143.5Ein4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.013 inഀ (after shores removed) 0.034 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.018 inഀ 0.018 inഀ Total Uncured Deflectionഀ 0.013 inഀ L/8418.5ഀ 0.034 in L / 3154.5ഀ Composite Deflectioഀ n 0.031 inഀ L/3534.0ഀ 0.052 in L / 2078.7ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 1.63 kഀ 1.63 kഀ Compositeഀ 2.25 kഀ 2.25 kഀ Max DL + LLഀ 3.88 kഀ 3.88 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 3.67 k-ft Fbഀ : Allowഀ 33.00 psi Based on Beam Span 2.250 ftഀ Dead + Constഀ 3.67 k-ft n :ഀ Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 5.06 k-ft n :ഀ Deflectionഀ 8.51ഀ Dead + Liveഀ 8.73 k-ftഀ Effective Width 2.250 ftഀ Support Shearsഀ Shear @ Leftഀ 3.88 kഀ Shear @ Rightഀ 3.88 kഀ Section Propertiesഀ Section Nameഀ W10X12ഀ Depthഀ 9.870 inഀ Ixx : Steel Sectionഀ 53.80 in4ഀ Widthഀ 3.960 inഀ I transformedഀ 222.87 in4ഀ Flange Thickഀ 0.210 inഀ Strans : topഀ 60.77 in3ഀ Web Thickഀ 0.190 inഀ Strans : botഀ 20.82 in3 .ഀ Areaഀ 3.540 in2ഀ Strains : eff @ botഀ 16.15 in3ഀ Weightഀ 12.024 #/ftഀ n'Strans : Ef @ topഀ 320.7 in3ഀ I-steelഀ 53.80 in4ഀ X-X Axis from Botഀ 10.70 inഀ S steel : topഀ 10.90 in3ഀ Vh @ 100%ഀ 88.50 kഀ S steel : bottomഀ 10.90 in3ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ Lഀ 303.623.4927ഀ Scopeഀ `Iഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ Page 1ഀ 550o.ecw:8182 beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Descriptionഀ Floor Beam - F139ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 ibU, 2uua NrrH ouuuഀ Section Nameഀ W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 13.000 Itഀ f'c 3,500.00 psiഀ Beam Spacingഀ 10.000 Itഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ am .ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.700 k/ft # 1 k ft Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 1.000 k/ft # 1 k ftഀ Summary OK Shored & Unshoredഀ Using: W 12X14, Span = 13.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 21,095.4 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 12,167.6 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 4,677.5 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 24,474.3 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 468.7 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 29,205.8 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n) 803.3 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 24.93 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 99.71 k Vh : Used 26.25 kഀ Zone 1 fromഀ Zone 2 fromഀ Zone 3 fromഀ Zone 4 fromഀ Zone 5 fromഀ Zone 6 fromഀ 0.000 ftഀ toഀ 2.167 ftഀ , Useഀ 1 studsഀ 2.167 ftഀ toഀ 4.333 ftഀ , Useഀ 2 studsഀ 4.333 ftഀ toഀ 6.500 ftഀ , Useഀ 0 studsഀ 6.500 ftഀ toഀ 8.667 ftഀ , Useഀ 0 studsഀ 8.667 ftഀ toഀ 10.833 ftഀ , Useഀ 2 studsഀ 10.833 ftഀ toഀ 13.000 Itഀ , Useഀ 1 studsഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB9ഀ ഀ Page 2ഀ 5500.ecw:8182 beamsഀ Deflectionsഀ I : Transformed 302.96 in4ഀ I : Effective 198.5ein4ഀ Shoredഀ Unshoredഀ Before 75 % Curing 0.080 inഀ (after shores removed) 0.179 inഀ Construction Loads Only 0.000 inഀ 0.000 inഀ After 75% Curing 0.112 inഀ 0.112 inഀ Total Uncured Deflection 0.080 inഀ L / 1958.7ഀ 0.179 in L / 873.9ഀ Composite Deflection 0.191 inഀ L / 815.7ഀ 0.290 in L / 537.8ഀ Reactionsഀ Load Combinations... @ Leftഀ @ Rightഀ Dead + Constuction 4.64 kഀ 4.64 kഀ Composite 6.50 kഀ 6.50 kഀ Max DL + LL 11.14 kഀ 11.14 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Alone 15.09 k-ft Fbഀ : Allowഀ 33.00 psi Based on Beam Span 1.625 ftഀ Dead + Const 15.09 k-ft n :ഀ Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Only 21.12 k-ft n :ഀ Deflectionഀ 8.51ഀ Dead + Live 36.21 k-ftഀ Effective Width 1.625 ftഀ Support Shearsഀ Shear @ Leftഀ 11.14 kഀ Shear @ Rightഀ 11.14 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 302.09 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 62.90 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.03 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 20.60 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 339.8 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 11.61 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 99.71 kഀ S steel : bottomഀ 14.88 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ 'r Fax: 303.623.6602ഀ V: 580001 Page 1ഀ er: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ 1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ -Aഀ Description Floor Beam - FB10ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W14X30ഀ Fy 50.00 ksiഀ Beam Spanഀ 17.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 10.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.700 k/ftഀ #1 4.050 k 4.500ftഀ #2 k/ftഀ #2 7.060 k 4.500ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 1.000 k/ftഀ # 2 k/ftഀ # 1ഀ # 2ഀ 5.400 kഀ 6.140 kഀ 4.500 ftഀ 4.500 ftഀ iummaryഀ OK Shored & Unshoredഀ Using: W 14X30, Span = 17.00ft, Slab Thickness = 4.500in, Deck Rib Hഀ t= 1.50in, Rib Spec= 6.00in, Rib Width=ഀ 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 29,255.8 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual = 16,349.1 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual = 8,392.2 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 32,118.4 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual = 785.0 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 35,341.3ഀ 38,000.0 psiഀ Shored Concrete Stress Check (MdI + MII) / (Strans:top' n)ഀ 1,456.3ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 32.60 kഀ Total req'd 112 Span 4studs Vh @ 100% 130.39k Vh : Used 26.25 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.662 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 1.662 ftഀ toഀ 3.324 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 3.324 ftഀ toഀ 4.987 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 4.987 ftഀ toഀ 8.991 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 8.991 ftഀ toഀ 12.996ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 12.996 ftഀ toഀ 17.000 ftഀ , Useഀ 1 studsഀ ~ CJ Iഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ L 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ 580001ഀ KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ 33-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB10ഀ Deflectionsഀ I : Transformedഀ 745.62 in4ഀ I : Effective 494.98n4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.195 inഀ (after shores removed) 0.331 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.234 inഀ 0.234 inഀ Total Uncured Deflectionഀ 0.195 inഀ L / 1047.2 0.331 in L / 615.6ഀ Composite Deflectionഀ 0.429 inഀ L / 475.7 0.565 in L / 360.9ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 14.37 kഀ 9.15 kഀ Compositeഀ 16.99 kഀ 11.55 kഀ Max DL + LLഀ 31.36 kഀ 20.70 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 57.29 k-ftഀ Fb : Allowഀ 33.00 psi Based on Beam Span 2.125 ftഀ Dead + Constഀ 57.29'k-ftഀ n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 66.76 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 123.85 k-ftഀ Effective Width 2.125 ftഀ Support Shearsഀ Shear @ Leftഀ 31.36 kഀ Shear @ Rightഀ 20.70 kഀ Section Propertiesഀ Section Nameഀ W1 4X30ഀ Depthഀ 13.840 inഀ Ixx : Steel Sectionഀ 291.00 in4ഀ Widthഀ 6.730 inഀ I transformedഀ 743.28 in4ഀ Flange Thickഀ 0.385 inഀ Strans : topഀ 118.67 in3ഀ Web Thickഀ 0.270 inഀ Strans : botഀ 61.55 in3ഀ Areaഀ 8.850 in2ഀ Strains : eff @ botഀ 50.80 in3ഀ Weightഀ 30.061 #/ftഀ n'Strans : Ef @ topഀ 657.3 in3ഀ I-steelഀ 291.00 in4ഀ X-X Axis from Botഀ 12.08 inഀ S steel : topഀ 42.05 in3ഀ Vh @ 100%ഀ 130.39 kഀ S steel : bottomഀ 42.05 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 - Page 1ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB11ഀ [Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Nameഀ W12X22ഀ Fy 50.00 ksiഀ Beam Spanഀ 18.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 22.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab One Sideഀ Dead Loadsഀ (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1ഀ 0.840 k/ftഀ #1 k ftഀ Live Loadsഀ (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 1.200 k/ft # 1ഀ Summaryഀ Using: W 12X22, Span = 18.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ kഀ ftഀ OK Shored & Unshoredഀ 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 29,839.2 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 16,529.2 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 5,798.3 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual =ഀ 33,894.3 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual =ഀ 710.8 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MIIഀ ) / Ssഀ 39,539.4ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top' n)ഀ 1,221.5ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 34.51 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 138.06k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 3.000ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 3.000 ftഀ toഀ 6.000 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 6.000 ftഀ toഀ 9.000ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 9.000 ftഀ toഀ 12.000ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 12.000 ftഀ toഀ 15.000ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 15.000 ftഀ toഀ 18.000ftഀ , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scope:ഀ Fax: 303.623.6602ഀ Rev: 580001 Page 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB11ഀ Deflectionsഀ -ഀ I : Transformedഀ 489.28 in4ഀ I . Effective 323.81in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.217 in (after shores removed)ഀ 0.450 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.302 inഀ 0.302 inഀ Total Uncured Deflectionഀ 0.217 in L / 996.7ഀ 0.450 in L / 480.2ഀ Composite Deflectionഀ 0.519 in L/ 416.5ഀ 0.752 in L / 287.4ഀ Reactionsഀ __.3. _ -ഀ - -ഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 7.76 kഀ 7.76 kഀ Compositeഀ 10.80 kഀ 10.80 kഀ Max DL + LLഀ 18.56 kഀ 18.56 kഀ Analysis Valuesഀ 9: _Sഀ iഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 34.91 k-ftഀ Fb : Allowഀ 33.00 psi Based on Beam Span 2.250 ftഀ Dead + Constഀ 34.91 k-ftഀ n : Strengthഀ 8.60 Based on Beam Spacing 11.000 ftഀ Live Load Onlyഀ 48.60 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 83.51 k-ftഀ Effective Width 2.250 ftഀ Support Shearsഀ Shear @ Leftഀ 18.56 kഀ Shear @ Rightഀ 18.56 kഀ Section Propertiesഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 487.85 in4ഀ Flange Thickഀ 0.425 inഀ Strains : topഀ 95.40 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 41.71 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 33.58 in3ഀ Weightഀ 22.011 #/ftഀ n*Strans : Ef @ tooഀ 521.3 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 11.70 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 138.06 kഀ S steel : bottomഀ 25.35 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ dr Fax: 303.623.6602ഀ rഀ Rev: 580001 Pageഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB12ഀ Design Inputഀ Code Ref: RISC 9th ASD 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X22ഀ Fy 50.00 ksiഀ Beam Spanഀ 12.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 22.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.840 k/ftഀ #1 5.150 k 7.500ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 1.200 k/ft # 1 7.420 k 7.500 ftഀ Summary OK Shored & Unshoredഀ ` Using: W12X22, Span = 12.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 23.01 kഀ Total req'd 1/2 Span 3 studs Vh Q 100% 92.04k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.480 ft , Useഀ 1 studsഀ Zone 2 fromഀ 2.480 ftഀ toഀ 4.960 ft , Useഀ 2 studsഀ Zone 3 fromഀ 4.960 ftഀ toഀ 7.440 ft , Useഀ 1 studsഀ Zone 4 fromഀ 7.440 ftഀ toഀ 8.960 ft , Useഀ 1 studsഀ Zone 5 fromഀ 8.960 ftഀ toഀ 10.480 ft , Useഀ 1 studsഀ Zone 6 fromഀ 10.480 ftഀ toഀ 12.000 ft , Useഀ 2 studsഀ Q Bottom of Beam Actual =ഀ 24,438.5 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 13,726.1 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 6,320.2 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual =ഀ 28,050.2 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual =ഀ 792.2 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl +ഀ MII) / Ssഀ 33,165.3ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ° n)ഀ 1,351.6ഀ 1,575.0 psiഀ +-6 'L 1ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pageഀ 2ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB12ഀ Deflectionsഀ I : Transformedഀ 434.55 in4ഀ I : Effective 327.77in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.073 inഀ (after shores removed) 0.154 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.103 inഀ 0.103 inഀ Total Uncured Deflectionഀ 0.073 inഀ L / 1967.8 0.154 in L / 936.6ഀ Composite Deflectionഀ 0.177 inഀ L / 815.4 0.257 in L / 560.0ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 7.10kഀ 8.39 kഀ Compositeഀ 9.98 kഀ 11.84 kഀ Max DL + LLഀ 17.09 kഀ 20.23 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 28.99 k-ft. Fb : Allowഀ 33.00 psi Based on Beam Span .ഀ 1.500 ftഀ Dead + Constഀ 28.99 k-ft n : Strengthഀ 8.60 Based on Beam Spacingഀ 11.000 ftഀ Live Load Onlyഀ 41.06 k-fit n : Deflectionഀ 8.51ഀ Dead + Liveഀ 70.05 k-ftഀ Effective Widthഀ 1.500 ftഀ Support Shearsഀ Shear @ Leftഀ 17.09 kഀ Shear @ Rightഀ 20.23 kഀ Section Propertiesഀ F.ഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 433.08 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 72.32 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 40.02 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 34.40 in3ഀ Weightഀ 22.011 #/ftഀ n*Strans : Ef @ topഀ 467.1 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 10.82 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 92.04 kഀ S steel : bottomഀ 25.35 in3ഀ r i71i(iഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ ' 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983.2003 ENERCALC Enoineerina Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB13ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14 Fy 50.00 ksiഀ Beam Span 9.000 ft f'c 3,500.00 psiഀ Beam Spacing 5.000 ft Concrete Density 145.00 pcfഀ Slab Thickness 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Height 1.500 inഀ Stud Height 3.000 inഀ Rib Spacing 6.000 inഀ Beam Weight Added Internallyഀ Rib Width 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ .Point Loads...ഀ # 1 0.350 k/ftഀ # 1 k ftഀ Live Loads (applied after 75% curing)ഀ fഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ Summary OK Shored & Unshoredഀ Using: W12X14, Span = 9.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Bഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 4,532.0 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 2,973.6 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 1,632.5 psiഀ : Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 5,595.9 psiഀ MII / Strans(top) Actual= 91.7 psiഀ Alternate Unshored Stress Check : (Mdl + M11) / Ssഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n)ഀ Allowable =ഀ Allowable =ഀ 7,056.7ഀ 158.4ഀ 45,000.0 psi OKഀ 1,575.0 psi OKഀ 38,000.0 psiഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 104.00k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.500ft , Useഀ 2 studsഀ Zone 2 fromഀ 1.500 ftഀ toഀ 3.000ft , Useഀ 1 studsഀ Zone 3 fromഀ 3.000 ftഀ toഀ 4.500 ft , Useഀ 1 studsഀ Zone 4 fromഀ 4.500 ftഀ toഀ 6.000ft , Useഀ 1 studsഀ Zone 5 fromഀ 6.000 ftഀ toഀ 7.500ft , Useഀ 1 studsഀ Zone 6 fromഀ 7.500 ftഀ toഀ 9.000 ft , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pageഀ User: KW-0606238, Ve, 1-Dec-2003 Composite Steel Beam (c)19833-2003 3 ENE ENERCALC LC En Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB13ഀ Deflectionsഀ I : Transformed 327.90 in4 I : Effective 253.83in4ഀ Shored Unshoredഀ Before 75 % Curing 0.007 in (after shores removed) 0.021 inഀ Construction Loads Only 0.000 in 0.000 inഀ After 75% Curing 0.010 in 0.010 inഀ Total Uncured Deflection 0.007 in L/####.# 0.021 in L / 5164.9ഀ Composite Deflection 0.017 in L/6232.6 0.031 in L / 3491.5ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 1.64 kഀ 1.64 kഀ Compositeഀ 2.25 kഀ 2.25 kഀ Max DL + LLഀ 3.89 kഀ 3.89 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 3.69 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.250 ftഀ Dead + Constഀ 3.69 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 5.06 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 8.75 k-ftഀ Effective Width 2.250 ftഀ Support Shearsഀ Shear @ Leftഀ 3.89 kഀ Shear @ Rightഀ 3.89 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 327.06 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 77.07 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.88 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 23.17 in3ഀ Weightഀ 14.130 #/ftഀ n`Strans : Ef @ topഀ 497.3 in3ഀ [-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 12.17 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ ` Fax: 303.623.6602ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (01983-2003 ENERCALC Enqineering Softwareഀ Descriptionഀ . - - _-----A=-ഀ Beam - FB14ഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 18.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.175k/ftഀ #1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.250 k/ft # 1 k ftഀ Summary OK Shored & Unshoredഀ Using: W 12X14, Span = 18.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 9,212.3 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 6,178.0 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 1,659.2 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 11,422.6 psiഀ Allowable = 45,000.0 psi OKഀ Mill / Strans(top) Actual = 183.3 psiഀ Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 14,344.2 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top' n)ഀ 322.0 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 112 Span 3 studs Vh @ 100% 104.00k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 3.000 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 3.000 ftഀ toഀ 6.000 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 6.000 ftഀ toഀ 9.000 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 9.000 ftഀ toഀ 12.000 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 12.000 ftഀ toഀ 15.000ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 15.000 ftഀ toഀ 18.000 ftഀ , Useഀ 2 studsഀ ~ _ ~j rഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door -Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602 _ഀ Rev: 580001 Page 2ഀ User: KW-0606238, Very-8-0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB14ഀ Deflectionsഀ LEVഀ I : Transformedഀ 327.90 in4ഀ I : Effective 253.82in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.061 inഀ (alter shores removed)ഀ 0.174 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.080 inഀ 0.080 inഀ Total Uncured Deflectionഀ 0.061 inഀ L /3561.1ഀ 0.174 in L / 1243.0ഀ Composite Deflectionഀ 0.141 inഀ L / 1533.1ഀ 0.254 in L / 850.6ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 1.70 kഀ 1.70 kഀ Compositeഀ 2.25 kഀ 2.25 kഀ Max DL + LLഀ 3.95 kഀ 3.95 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 7.66 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.250 ftഀ Dead + Constഀ 7.66 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 2.500 ftഀ Live Load Onlyഀ 10.12 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 17.78 k-ftഀ Effective Width 2.250 ftഀ Support Shearsഀ Shear @ Leftഀ 3.95 kഀ Shear @ Rightഀ 3.95 kഀ Section Propertiesഀ Section Nameഀ W12X14,ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 327.06 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 77.07 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.88 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 23.17 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 497.3 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 12.17 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope:ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983.2003 ENERCALC Engineering Softwareഀ -25321MMUM SEE=ഀ Description Floor Beam - FB15ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 500019ഀ Section Name W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 10.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 15.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.525 k/ftഀ #1 1.700 k 6.000ftഀ #2 k/ftഀ #2 1.640 k 6.000ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.750 k/ft # 1 2.250 k 6.000 ftഀ # 2 k/ft # 2 2.250 k 6.000 ftഀ OK Shored & Unshoredഀ Using: W1 2X14, Span = 10.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 18,737.2 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 11,683.3 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 4,680.8 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 22,504.1 psiഀ Allowable =ഀ 45,000.0 psi OKഀ MII / Strans(top) Actual = 330.9 psiഀ Allowable =ഀ 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 27,652.9ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n)ഀ 573.0ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 104.00k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.000 ft , Useഀ 1 studsഀ Zone 2 fromഀ 2.000 ftഀ toഀ 4.000ft , Useഀ 2 studsഀ Zone 3 fromഀ 4.000 ftഀ toഀ 6.000ft , Useഀ 1 studsഀ Zone 4 fromഀ 6.000 ftഀ toഀ 7.333 ft , Useഀ 1 studsഀ Zone 5 fromഀ 7.333 ftഀ toഀ 8.667 ft , Useഀ 1 studsഀ Zone 6 fromഀ 8.667 ftഀ toഀ 10.000 ft , Useഀ 2 studsഀ Page 1ഀ 5500.ecw:8182 beamsഀ rr? I, tഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Page 2ഀ Lev5 a0?0 01ഀ W-0606238, V er 5.8.0, 1-Dec-2003 Comp„osite Steel Beamഀ 3-2003 ENERCALC Engineering Software r 5500.ecw:8182 beamsഀ Description Floor Beam - FB15ഀ Deflectionsഀ I : Transformedഀ 336.37 in4ഀ I : Effective 232.34in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.035 inഀ (after shores removed)ഀ 0.091 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.048 inഀ 0.048 inഀ Total Uncured Deflectionഀ 0.035 inഀ L/3440.8ഀ 0.091 in L / 1312.1ഀ Composite Deflectionഀ 0.083 inഀ L / 1451.5ഀ 0.139 in L / 861.9ഀ LReactionsഀ Load Combinations...ഀ @ Leftഀ @ Riqhtഀ Dead + Constuctionഀ 4.03 kഀ 4.70 kഀ Compositeഀ 5.55 kഀ 6.45 kഀ Max DL + LLഀ 9.58 kഀ 11.15 kഀ Analysis Valuesഀ iഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 14.49 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.500 ftഀ Dead + Constഀ 14.49 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 15.000 ftഀ Live Load Onlyഀ 19.80 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 34.29 k-ftഀ Effective Width 2.500 ftഀ Support Shearsഀ Shear @ Leftഀ 9.58 kഀ Shear @ Rightഀ 11.15 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 335.57 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 83.49 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 27.08 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 21.96 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 470.3 in3ഀ ]-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 12.39 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ Rev: 580007ഀ User: KW-06Cഀ (c) 1983-2003ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ 1-Dec-2003 Multi-Span Steel Beamഀ ineering Softwareഀ Descriptionഀ Floor Beam - FB16 - Non compഀ Page 1ഀ 5500.ecw:8182 beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ -ഀ -MM Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Leftഀ Rightഀ Span ftഀ 20.00ഀ 8.50ഀ Steel Sectionഀ w14x43ഀ w14x43ഀ End Fixityഀ Pin-Pinഀ Pin-Pinഀ Unbraced Length ftഀ 0.50ഀ 0.50ഀ Loadsഀ uve Load used i his span Yഀ Dead Loadഀ k/ftഀ Live Loadഀ k/ftഀ Point #1 DLഀ kഀ LLഀ kഀ @Xഀ ftഀ Point #2 DLഀ kഀ LLഀ kഀ @Xഀ ftഀ Point #3 DLഀ kഀ LLഀ kഀ @Xഀ ftഀ ഀ Yesഀ Yesഀ 0.350ഀ 0.350ഀ 0.500ഀ 0.500ഀ 14.560ഀ 5.150ഀ 25.041ഀ 7.420ഀ 14.500ഀ 2.500ഀ 4.030ഀ 5.550ഀ 2.500ഀ 4.540ഀ 6.250ഀ 5.000ഀ Resultsഀ _2-_ഀ Mmax @ Cntrഀ k-ft 1ഀ 88.63ഀ 0.00ഀ @ X =ഀ ftഀ 14.40ഀ 8.50ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -142.31ഀ Max @ Right Endഀ k-ftഀ -142.31ഀ 0.00ഀ fb : Actualഀ psiഀ 27,251.9ഀ 27,251.9ഀ Fb ; Allowableഀ psiഀ 33,000.0ഀ 33,000.0ഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 10,639.2ഀ 9,704.8ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ k~ഀ 12.27ഀ 40.43ഀ Shear @ Rightഀ kഀ 44.33ഀ 0.27ഀ Reactions...ഀ DL @ Leftഀ kഀ 4.78ഀ 33.02ഀ LL @ Leftഀ kഀ 7.49ഀ 51.74ഀ Total @ Leftഀ k'ഀ 12.27ഀ 84.76ഀ DL @ Rightഀ k,ഀ 33.02ഀ 0.45ഀ LL @ Rightഀ kഀ 51.74ഀ -0.72ഀ Total @ Rightഀ kഀ 84.76ഀ -0.27ഀ Max. Deflectionഀ in lഀ -0.433ഀ 0.037ഀ @ X =ഀ ftഀ 10.13ഀ 2.78ഀ Span/Deflection Ratioഀ 554.5ഀ 2,743.5ഀ Query Valuesഀ Locationഀ ft 1ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ k Iഀ 12.27ഀ 40.43ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Momentഀ k-ftഀ -0.00ഀ -142.31ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Max. Deflectionഀ in !ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Ds9nr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Enqineerinq Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB17ഀ Design Inputഀ Code Ref: AISC 9th ASD 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 15.000 Itഀ ft 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpenഀ dicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.350 k/ftഀ #1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ aurnrnary OK Shored & Unshoredഀ Using: W 12X14, Span = 15.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 12,206.4 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 8,260.0 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 2,720.8 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 15,322.8 psiഀ MII / Strans(top) Actual = 181.9 psiഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top ` n)ഀ Allowable = 45,000.0 psi OKഀ Allowable = 1,575.0 psi OKഀ 19,602.0 38,000.0 psiഀ 314.5 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 104.00k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.500 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 2.500 ftഀ toഀ 5.000 Itഀ , Useഀ 1 studsഀ Zone 3 fromഀ 5.000 ftഀ toഀ 7.500 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 7.500 ftഀ toഀ 10.000 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 10.000 ftഀ toഀ 12.500 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 12.500 ftഀ toഀ 15.000 ftഀ , Useഀ 2 studsഀ ~_S30ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ L 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Page 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB17ഀ Deflectionsഀ I : Transformedഀ Before 75 % Curingഀ Construction Loads Onlyഀ After 75% Curingഀ Total Uncured Deflectionഀ Composite Deflectionഀ 11ഀ - _ഀ -_N___ഀ 364.81 in4ഀ I : Effective 279.32in4ഀ Shoredഀ Unshoredഀ 0.051 in (aRershoresremoved)ഀ 0.161 inഀ 0.000 inഀ 0.000 inഀ 0.070 inഀ 0.070 inഀ 0.051 in L/3517.1ഀ 0.161 in L/ 1115.6ഀ 0.122 in L / 1481.4ഀ 0.232 in L/ 777.1ഀ Reactionsഀ Load Combinations...ഀ Dead + Constuctionഀ Compositeഀ Max DL + LLഀ @ Left @ Riohtഀ 2.73 k 2.73 kഀ 3.75 k 3.75 kഀ 6.48 kഀ 6.48 kഀ Analysis Valuesഀ Maximum Momentsഀ Dead Load Aloneഀ Dead + Constഀ Live Load Onlyഀ Dead + Liveഀ 10.24 k-ft . Fb : Allowഀ 10.24 k-ft n : Strengthഀ 14.06 k-ft n : Deflectionഀ 24.30 k-ftഀ Effective Flange Width...ഀ 33.00 psi Based on Beam Span 3.750 ftഀ 8.60 Based on Beam Spacing 5.000 ftഀ 8.51ഀ Effective Width 3.750 ftഀ Support Shearsഀ Shear @ Leftഀ 6.48 kഀ Shear @ Rightഀ 6.48 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 364.09 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 107.85 in3ഀ Web Thickഀ 0.200 inഀ Strains : botഀ 27.93 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 23.89 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 680.0 in3ഀ ]-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 13.03 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ !-('-rഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User; KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Encineerinc Software 5500.ecw:8182 beamsഀ Description Floor Beam --F518ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14 Fy 50.00 ksiഀ Beam Span 9.000 ft f'c 3,500.00 psiഀ Beam Spacing 5.000 ft Concrete Density 145.00 pcfഀ Slab Thickness 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Height 1.500 inഀ Stud Height 3.000 inഀ Rib Spacing 6.000 inഀ Beam Weight Added Internallyഀ Rib Width 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.350 k/ftഀ # 1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ 17uuuuai y OK Shored &Unshoredഀ Using: W 12X14, Span = 9.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spec= 6.00in, Rib Width= 1.75in w/ Slab Bഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 4,532.0 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 2,973.6 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 1,632.5 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 5,595.9 psiഀ Allowable =ഀ 45,000.0 psi OKഀ MII / Strans(top) Actual = 91.7 psiഀ Allowable =ഀ 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 7,056.7ഀ 38,000.0 psiഀ Shored Concrete Stress Check....(Mdl + MII) / (Strans(top ' n)ഀ 158.4ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 104.00k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.500 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 1.500 ftഀ toഀ 3.000 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 3.000 ftഀ toഀ 4.500 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 4.500 ftഀ toഀ 6.000 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 6.000 ftഀ toഀ 7.500 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 7.500 ftഀ toഀ 9.000 ftഀ , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ ' 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Y' Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - F1318ഀ Deflectionsഀ I : Transformed 327.90 in4 I : Effective 253.85in4ഀ Shored Unshoredഀ Before 75 % Curing 0.007 in (after shores removed) 0.021 inഀ Construction Loads Only 0.000 in 0.000 inഀ After 75% Curing 0.010 in 0.010 inഀ Total Uncured Deflection 0.007 in L/####.# 0.021 in L/ 5164.9ഀ Composite Deflection 0.017 in L/6232.6 0.031 in L / 3491.5ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 1.64 kഀ 1464 kഀ Compositeഀ 2425 kഀ 2.25 kഀ Max DL + LLഀ 3.89 kഀ 3.89 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 3.69 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.250 ftഀ Dead + Constഀ 3469 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 5.06 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 8.75 k-ftഀ Effective Width 2.250 ftഀ Support Shearsഀ Shear @ Leftഀ 3.89 kഀ Shear @ Rightഀ 3.89 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 327.06 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 77.07 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.88 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 23.17 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 497.3 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 12.17 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ !"1:3 5ഀ ? Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scope :ഀ Fax: 303.623.6602ഀ Rev: 580001 Page 1ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beam 5500.ecw:8182 beamsഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB19ഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Design Inputഀ Y.ഀ Section Nameഀ W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 12.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab Both Sidesഀ Dead Loadsഀ (applied before 75% curing)ഀ Full Span Uniform Loads... tഀ Point Loads...ഀ #1ഀ 0.350 k/ftഀ #1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ # 1 0.500 k/ftഀ ഀ Mm=ഀ Point Loads...ഀ #1 kഀ ftഀ Summary - OK Shored & Unshoredഀ Using: W12X14, Span = 12.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 7,913.8 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 5,286.4 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 2,176.6 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 9,865.4 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 134.3 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 12,545.3 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ` n) 232.1 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total redd 1/2 Span 3 studs Vh @ 100% 104.00k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 Itഀ toഀ 2.000ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 2.000 ftഀ toഀ 4.000ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 4.000 ftഀ toഀ 6.000 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 6.000 Itഀ toഀ 8.000ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 8.000 ftഀ toഀ 10.000 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 10.000 ftഀ toഀ 12.000 ftഀ , Useഀ 2 studsഀ 1 n .ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ Pa e 2ഀ gഀ (c)1983-2003 ENERCALC Enqineerinq Softwareഀ 5500.ecw:8182 beamsഀ Description Floor Beam - FB19ഀ Deflectionsഀ I : Transformedഀ 349.38 in4ഀ I : Effective 268.67in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.022 in (after shores removed)ഀ 0.066 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.030 inഀ 0.030 inഀ Total Uncured Deflectionഀ 0.022 in L / 6607.3ഀ 0.066 in L / 2178.9ഀ Composite Deflectionഀ 0.052 in L/2783.0ഀ 0.096 in L / 1499.8ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Riohtഀ Dead + Constuctionഀ 2.18 kഀ 2.18 kഀ Compositeഀ 3.00 kഀ 3.00 kഀ MaxDL+LLഀ 5.18kഀ 5.18kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 6.55 k-ftഀ Fb : Allow 33.00 psi Based on Beam Span 3.000 ftഀ Dead + Constഀ 6.55 k-ftഀ n : Strength 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 9.00 k-ftഀ n : Deflection 8.51ഀ Dead + Liveഀ 15.55 k-ftഀ Effective Width 3.000 ftഀ Support Shearsഀ Shear @ Leftഀ 5.18 kഀ Shear @ Rightഀ 5.18 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 348.61 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 93.50 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 27.49 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 23.59 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 594.8 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 12.68 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ t~ jcഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 6:09AM, 15 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ L 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5-8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8182 beamsഀ Description Floor Beam - FB20ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W14X22 Fy 50.00 ksiഀ Beam Span 19.000 ft f'c 3,500.00 psiഀ Beam Spacing 5.000 ft Concrete Density 145.00 pcfഀ Slab Thickness 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Height 1.500 inഀ Stud Height 3.000 inഀ Rib Spacing 6.000 inഀ Beam Weight Added Internallyഀ Rib Width 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.700 k/ftഀ #1 kഀ ftഀ Live Loads (applied after 75% curing)ഀ -ഀ -ഀ ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 1.000 k/ftഀ Summaryഀ #1 kഀ ftഀ OK Shored & Unshoredഀ Using: W 14X22, Span = 19.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 23,926.1 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 13,497.9 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 5,176.7 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 27,391.9 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 356.3 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + VIII) / Ss 32,191.9 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top " n) 613.5 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 5 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 40.56 kഀ Total req'd 1/2 Span 5studs Vh @ 100% 162.25k Vh : Used 43.75 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 3.167 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 3.167 ftഀ toഀ 6.333 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 6.333 ftഀ toഀ 9.500 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 9.500 ftഀ toഀ 12.667 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 12.667 ftഀ toഀ 15.833 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 15.833 ftഀ toഀ 19.000 ftഀ , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ User: M (-0 06238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB20ഀ Composite Steel Beamഀ 2 __-,E - &ഀ Page 2ഀ 5500.ecw:8182 beamsഀ Deflectionsഀ I : Transformedഀ 692.61 in4ഀ Iഀ : Effective 455.32in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.160 inഀ (after shores removed)ഀ 0.367 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.222 inഀ 0.222 inഀ Total Uncured Deflectionഀ 0.160 inഀ L / 1422.7ഀ 0.367 in L / 621.8ഀ Composite Deflectionഀ 0.382 inഀ L / 596.3ഀ 0.589 in L / 387.3ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 6.86 kഀ 6.86 kഀ Compositeഀ 9.50 kഀ 9.50 kഀ Max DL + LLഀ 16.36 kഀ 16.36 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 32.58 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 4.750 ftഀ Dead + Constഀ 32.58 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 45.12 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 77.71 k-ftഀ Effective Width 4.750 ftഀ Support Shearsഀ Shear @ Leftഀ 16.36 kഀ Shear @ Rightഀ 16.36 kഀ Section Propertiesഀ Section Nameഀ W14X22ഀ Depthഀ 13.740 inഀ Ixx : Steel Sectionഀ 199.00 in4ഀ Widthഀ 5.000 inഀ I transformedഀ 691.20 in4ഀ Flange Thickഀ 0.335 inഀ Strans : topഀ 176.73 in3ഀ Web Thickഀ 0.230 inഀ Strans : botഀ 48.24 in3ഀ Areaഀ 6.490 1n2ഀ Strans : eff @ botഀ 38.97 in3ഀ Weightഀ 22.045 #/ftഀ n`Strans : Ef @ topഀ 909.0 in3ഀ I-steelഀ 199.00 in4ഀ X-X Axis from Botഀ 14.33 inഀ S steel : topഀ 28.97 in3ഀ Vh @ 100%ഀ 162.25 kഀ S steel : bottomഀ 28.97 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ nev. 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB21ഀ Composite Steel Beamഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14 Fy 50.00 ksiഀ Beam Span 8.000 ft f'c 3,500.00 psiഀ Beam Spacing 10.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ Deck Rib Heightഀ Rib Spacingഀ Rib Widthഀ Rib Orientationഀ Beam Locationഀ 4.500 inഀ 1.500 inഀ 6.000 inഀ 1.750 inഀ Parallelഀ Slab One Sideഀ Stud Diameter 0.750 inഀ Stud Height 3.000 inഀ Beam Weight Added Internallyഀ Using Partial Composite Actionഀ Elastic Modulus 29,000.00 ksiഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.350 k/ft # 1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.500 k/ft # 1 k ftഀ Summaryഀ OK Shored & Unshoredഀ Using: W12X14, Span = 8.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 3,718.2 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 2,349.5 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 1,451.1 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 4,500.9 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 123.8 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 5,575.7 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n) 214.0 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacityഀ Total req'd 1/2 Span 2 studs Vh @ 100%ഀ Page 1ഀ 5500.ecw:8182 beamsഀ 8.75 k V'h : min 15.34 kഀ 61.36k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 Itഀ toഀ 1.333 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 1.333 ftഀ toഀ 2.667 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 2.667 ftഀ toഀ 4.000 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 4.000 ftഀ toഀ 5.333 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 5.333 ftഀ toഀ 6.667 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 6.667 ftഀ toഀ 8.000 ftഀ , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User KW-0606238, Verഀ (c)1983-2003 ENERCALഀ Description Floor Beam - FB21ഀ Composite Steel Beamഀ Page 2ഀ 5500.ecw:8182 beamsഀ Deflectionsഀ I : Transformedഀ 262.87 in4 Iഀ : Effectiveഀ 220.22in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.005 in (after shores removed)ഀ 0.013 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.007 inഀ 0.007 inഀ Total Uncured Deflectionഀ 0.005 in Lഀ 0.013 inഀ L / 7353.9ഀ Composite Deflectionഀ 0.012 in L /7698.9ഀ 0.020 inഀ L / 4737.0ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 1.46 kഀ 1.46 kഀ Compositeഀ 2.00 kഀ 2.00 kഀ Max DL + LLഀ 3.46 kഀ 3.46 kഀ Analysis Valuesഀ 1ഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 2.91 k-ftഀ Fb : Allow 33.00 psi Based on Beam Span 1.000 ftഀ Dead + Constഀ 2.91 k-ftഀ n : Strength 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 4.00 k-ftഀ n : Deflection 8.51ഀ Dead + Liveഀ 6.91 k-ftഀ Effective Width 1.000 ftഀ Support Shearsഀ Shear @ Leftഀ 3.46 kഀ Shear @ Rightഀ 3.46 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 261.96 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 45.07 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 24.72 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 22.31 in3ഀ Weightഀ 14.130 #/ftഀ n`Strans : Ef @ topഀ 324.0 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 10.60 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 61.36 kഀ S steel : bottomഀ 14.88 in3ഀ Title : Vail's Front Door Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ r~ r'zഀ Job # 5500.02ഀ Date: 6:09AM. 15 DEC 05ഀ r,ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500ഀ 02ഀ `ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PE Date: 6:09AM,ഀ .ഀ 15 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: "2ഀ 0ഀ 1ഀ 0ഀ 6ഀ 06238,ഀ er: K3 I ENERCALC LC Engineering V Compositeഀ (c)1983-200 ENEginneering eering Softwareഀ Steel Beamഀ Page 1ഀ 5500.ecw:8182 beamsഀ Descriptionഀ Floor Beam - FB22ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Nameഀ W14X22ഀ Fy 50.00 ksiഀ Beam Spanഀ 14.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 5.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29ഀ 000.00 ksiഀ Beam Locationഀ Slab Both Sidesഀ ,ഀ Dead Loads (applied before 75% curing)ഀ NQഀ Full Span Uniform Loads...ഀ Point Loads....ഀ # 1 0.350 k/ftഀ # 1ഀ 6.860 kഀ 5.000ftഀ # 2 k/ftഀ # 2ഀ 0.970 kഀ 6.000ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ftഀ # 1ഀ 9.500 kഀ 5.000 ftഀ # 2 k/ftഀ # 2ഀ 3.230 kഀ 6.000 ftഀ Summaryഀ OK Shored & Unshoredഀ Using: W 14X22, Span = 14.00ft, Slab Thicknessഀ = 4.500in, Deck Ribഀ Ht= 1.50in, Rib Spacഀ = 6.00in, Rib Widtഀ h= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 25,830.7 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 13,731.5 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 6,019.1 psiഀ Allowable = .ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 29,386.2 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 497.3 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 34,856.0 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top * n) 820.5 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 4 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 40.56 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 162.25k Vh : Used 49.58 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.680 ft , Useഀ 1 studsഀ Zone 2 fromഀ 1.680 ftഀ toഀ 3.360 ft , Useഀ 2 studsഀ Zone 3 fromഀ 3.360 ftഀ toഀ 5.040 ft , Useഀ 1 studsഀ Zone 4 fromഀ 5.040 ftഀ toഀ 8.027 It , Useഀ 1 studsഀ Zone 5 fromഀ 8.027 ftഀ toഀ 11.013 ft , Useഀ 1 studsഀ Zone 6 fromഀ 11.013 ftഀ toഀ 14.000 ft , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ 1983-2003ഀ Ver 5.8.0, 1-Dec-2003ഀ CALC Engineering Softwareഀ Composite Steel Beamഀ Page 2ഀ 5500.ecw:8182 beamsഀ Description Floor Beam FB22ഀ Deflectionsഀ I : Transformedഀ 649.71 in4ഀ I : Effective 448.1 Ein4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.078 inഀ (after shores removed) 0.177 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.122 inഀ 0.122 inഀ Total Uncured Deflectionഀ 0.078 inഀ L/2140.4 0.177 in L / 950.4ഀ Composite Deflectionഀ 0.200 inഀ L / 839.2 0.298 in : L / 563.0ഀ Reactionsഀ Load Combinations... @ Left @ Rightഀ .Dead + Constuction 7.57 k • 5.47 kഀ Compositeഀ 11.45 kഀ 8.28 kഀ Max DL + LLഀ 19.02 kഀ 13.75 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 33.15 k-ftഀ Fb : Allowഀ 33.00 psiഀ Based on Beam Span 3.500 ftഀ Dead + Constഀ 33.15 k-ftഀ n : Strengthഀ 8.60ഀ Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 50.99 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 84.14 k-ftഀ Effective Width 3.500 ftഀ Support Shearsഀ Shear @ Leftഀ 19.02 kഀ Shear @ Rightഀ 13.75 kഀ Section Propertiesഀ Section Nameഀ W14X22ഀ Depthഀ 13.740 inഀ Ixx : Steel Sectionഀ 199.00 in4ഀ Widthഀ 5.000 inഀ I transformedഀ 648.14 in4ഀ Flange Thickഀ 0.335 inഀ Strans : topഀ 143.08 in3ഀ Web Thickഀ 0.230 inഀ Strans : botഀ 47.27 in3ഀ Areaഀ 6.490 in2ഀ Strans : eff @ botഀ 39.09 in3ഀ Weightഀ 22.045 #/ftഀ n'Strans : Ef @ topഀ 791.6 in3ഀ I-steelഀ 199.00 in4ഀ X-X Axis from Botഀ 13.71 inഀ S steel : topഀ 28.97 in3ഀ Vh @ 100%ഀ 162.25 kഀ S steel : bottomഀ 28.97 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Scope :ഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi -Span Steel -Beamഀ (c)1983-2003 ENERCALC Engineering softwareഀ Page 1ഀ 5500.ecw:8182 beamsഀ Description Floor Beam - FB23 - Non Compഀ General Informationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Descriptionഀ Cant spanഀ Iഀ Span ft 4.00 15.00ഀ Steel Section w14x30 w14x30ഀ End Fixity Free-Pin Pin-Pinഀ Unbraced Length ft 4.00 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yes Yesഀ Dead Load k/ftഀ 0.175 0.350ഀ Live Load k/ftഀ 0.250 0.500ഀ Point #1 DL kഀ 1.460 1.140ഀ LL kഀ 2.000 3.750ഀ @ X ftഀ 1.000ഀ Point #2 DL kഀ 1.300 6.860ഀ LL kഀ 4.330 9.500ഀ @ X ftഀ 6.000ഀ Point #3 DL kഀ 2.810ഀ LL kഀ 9.400ഀ @ X ftഀ 7.000ഀ ~ Resultsഀ Mmax @ Cntrഀ k-ftഀ 0.00ഀ 103.14ഀ @ X =ഀ ftഀ 0.00ഀ 7.00ഀ Max @ Left Endഀ k-ft ~ഀ 0.00ഀ -39.76ഀ Max @ Right Endഀ k-ftഀ -39.76ഀ 0.00ഀ fb : Actualഀ psiഀ 11,345.7ഀ 29,431.8ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ 33,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ psiഀ 2,887.5ഀ 8,006.2ഀ Fv : Allowableഀ psi iഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ isഀ -ഀ -ഀ _ഀ .ഀ ഀ Shear @ Leftഀ kഀ 0.00ഀ 29.92ഀ Shear @ Rightഀ kഀ 10.79ഀ 16.29ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 13.59ഀ LL @ Leftഀ kഀ 0.00ഀ 27.11ഀ Total @ Leftഀ k;ഀ 0.00ഀ 40.71ഀ DL @ Rightഀ k jഀ 13.59ഀ 5.93ഀ LL @ Rightഀ k jഀ 27.11ഀ 10.37ഀ Total @ Rightഀ kഀ 40.71ഀ 16.29ഀ Max. Deflectionഀ inഀ 0.245ഀ -0.411ഀ @ X =ഀ ftഀ 0.00ഀ 7.40ഀ Span/Deflection Ratioഀ 392.6ഀ 437.7ഀ Query Valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0ഀ 00ഀ 0ഀ 00ഀ Shearഀ kഀ 0.00ഀ 29.92ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Momentഀ k-ftഀ 0.00ഀ -39.76ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0ഀ 00ഀ .ഀ 0ഀ 00ഀ Max. Deflectionഀ inഀ 0.2445ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 6:09AM, 15 DEC 05ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description or Beam - FB24ഀ Page 1ഀ 5500.ecw:8182 beamsഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Nameഀ W1 2X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 8.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 10.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29ഀ 000ഀ 00 ksiഀ Beam Locationഀ Slab One Sideഀ ,ഀ .ഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.350 k/ft # 1 k ftഀ Live Loadsഀ (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.500 k/ftഀ # 1ഀ kഀ ftഀ Summaryഀ _ഀ OK Shorഀ ed & Unshoredഀ Using: W 12X14, Span= 8.00ft, Slab Thickness= 4.500in, Deck Rib Hഀ t= 1.50in, Rib Spac=ഀ 6.00in, Rib Widthഀ = 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 3,396.5 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Unshored DL Stress Actual = 2,349.5 psiഀ Allowable =ഀ 33,333.0 psiഀ OKഀ Actual Shear Stress Actual = 1,451.1 psiഀ Allowable =ഀ 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 4,314.8 psiഀ Allowable =ഀ 45,000.0 psiഀ OKഀ MII / Strans(top) Actual = 128.5 psiഀ Allowable =ഀ 1,575.0 psiഀ OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 5,575.7ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top ' n)ഀ 222.1ഀ 1,575.0 psiഀ 5near Studs & Shear Transferഀ Actual # Studsഀ Total req'd 112 Spanഀ Zone 1 fromഀ Zone 2 fromഀ Zone 3 fromഀ Zone 4 fromഀ Zone 5 fromഀ Zone 6 fromഀ 4 per 1/2 beam spanഀ Stud Capacityഀ 2 studsഀ Vh @ 100%ഀ 0.000 ftഀ toഀ 1.333 ftഀ toഀ 2.667 ftഀ toഀ 4.000 ftഀ toഀ 5.333 ftഀ toഀ 6.667 ftഀ toഀ 12.40 kഀ 53.55 kഀ 1.333 ft , Useഀ 2.667 ft , Useഀ 4.000ft , Useഀ 5.333 ft , Useഀ 6.667 ft Useഀ 8.000ft , Useഀ 2 studsഀ 1 studsഀ 1 studsഀ 1 studsഀ 1 studsഀ 2 studsഀ V'h : min 13.39 kഀ Vh : Used 49.58 kഀ rഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Scope :ഀ Rev: 580001ഀ User: KW-0606238, V0, 1-Dec-2003 Composite Steel Beamഀ (c)19833-2 -2003 3 ENERCALC ALC E Engineering Softwareഀ Page 2ഀ 5500.ecw:8182 beamsഀ Descriptionഀ Floor Beam - FB24ഀ Deflectionsഀ I Transformed 260.00 in4ഀ I : Effective 253.53in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.005 in (after shores remഀ oved) 0.013 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.006 inഀ 0.006 inഀ Total Uncured Deflectionഀ 0.005 inഀ 0.013 in L / 7353.9ഀ Composite Deflectionഀ 0.011 in L/8863.4ഀ 0.019 in L / 4969.3ഀ Reactionsഀ Load Combinationsഀ 22ഀ @ Leftഀ @ Rightഀ Dead + Constuction 1.46 kഀ 1.46 kഀ Composite 2.00 kഀ 2.00 kഀ Max DL + LL 3.46 kഀ 3.46 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Alone 2.91 k-ft .ഀ Fb : Allowഀ 33.00 psi Based on Beam Span 1.000 ftഀ Dead + Const 2.91 k-ftഀ n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Only 4.00 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Live 6.91 k-ftഀ Effective Width 1.000 ftഀ Support Shearsഀ Shear @ Left 3.46 kഀ Shear @ Right 3.46 kഀ Section Propertiesഀ Section Name W12X14ഀ Depth 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Width 3.970 inഀ I transformedഀ 259.06 in4ഀ Flange Thick 0.225 inഀ Strans : topഀ 43.44 in3ഀ Web Thick 0.200 inഀ Strans : botഀ 24.80 in3ഀ Area 4.160 in2ഀ Strans : eff @ botഀ 24.42 in3ഀ Weight 14.130 #/ftഀ n'Strans : Ef @ topഀ 364.3 in3ഀ I-steel 88.60 in4ഀ X-X Axis from Botഀ 10.45 inഀ S steel : top 14.88 in3ഀ Vh @ 100%ഀ 53.55 kഀ S steel : bottom 14.88 in3ഀ Monroe & Newell Engineers, Inc.ഀ ( 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ ~annniഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ ~~,4r,-ഀ Job # 5500.02ഀ Date: 6:46AM, 15 DEC 05ഀ User: -2KW-0606238, Ver 5.8.0, -Dec-2003ഀ (c)19833-2003 3 ENE NERCALC ALC Engineering Softwareഀ g Software Composite Steel Beam Page 1ഀ 5500.ecwV82 beamsഀ Description Floor Beam - FB25ഀ Design Inputഀ Section Nameഀ Beam Spanഀ Beam Spacingഀ Slab Thicknessഀ Deck Rib Heightഀ Rib Spacingഀ Rib Widthഀ Rib Orientationഀ Beam Locationഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ W14X26ഀ Fy 50.00 ksiഀ 18.000 ftഀ f'c 3,500.00 psiഀ 16.000 ftഀ Concrete Density 145.00 pcfഀ 4.500 inഀ Stud Diameter 0.750 inഀ 1.500 inഀ Stud Height 3.000 inഀ 6.000 inഀ Beam Weight Added Internallyഀ 1.750 inഀ Using Partial Composite Actionഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Slab Both Sidesഀ veaa LOaCIS (applied before 75% curing)ഀ - -7, . .ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 1.120 k/ft # 1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads.., aഀ #1 1.600 k/ft # 1 k ftഀ r = OK Shored & Unshoredഀ Using: W14X26, Span = 18.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 28,658.7 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 15,812.4 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 6,967.8 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Checkഀ (Mdl/Ss + MII/Strans) Actual = 32,510.1 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 487.9 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 37,886.7 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top * n) 837.3 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studsഀ Total req'd 1/2 Spanഀ Zone 1 fromഀ Zone 2 fromഀ Zone 3 fromഀ Zone 4 fromഀ Zone 5 fromഀ Zone 6 fromഀ 6 per 1/2 beam spanഀ Stud Capacityഀ 6 studs Vh @ 100%ഀ 8.75 k V'h : min 48.06 kഀ 192.25k Vh : Used 52.50 kഀ 0.000 ftഀ toഀ 3.000 ft , Useഀ 2 studsഀ 3.000 ftഀ toഀ 6.000 ft , Useഀ 3 studsഀ 6.000 ftഀ toഀ 9.000 ft , Useഀ 1 studsഀ 9.000 ftഀ toഀ 12.000 ft , Useഀ 1 studsഀ 12.000 ftഀ toഀ 15.000 ft , Useഀ 3 studsഀ 15.000 ftഀ toഀ 18.000 ft , Useഀ 2 studsഀ c~ A,5ഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ L. 303.623.4927ഀ ` Fax: 303.623.6602ഀ Rev. 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB25ഀ Deflectionsഀ I : Transformedഀ 803.61 in4ഀ I : Effective _ 536.92in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.174 inഀ (after shores removed)ഀ 0.381 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.243 inഀ 0.243 inഀ Total Uncured Deflectionഀ 0.174 inഀ L/1243.0ഀ 0.381 in L / 567.2ഀ Composite Deflectionഀ 0.417 inഀ L / 518.6ഀ 0.623 in L / 346.5ഀ Reactionsഀ Load Combinationsഀ Rഀ ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 10.32 kഀ 10.32 kഀ Compositeഀ 14.40 kഀ 14.40 kഀ Max DL + LLഀ 24.72 kഀ 24.72 kഀ Analysis valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Alone •ഀ 46.42 k-ftഀ Fb : Allowഀ 33.00 psiഀ Based on Beam Span 4.500 ftഀ Dead + Constഀ 46.42 k-ftഀ n : Strengthഀ 8.60ഀ Based on Beam Spacing 16.000 ftഀ Live Load Onlyഀ 64.80 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 111.22 k-ftഀ Effective Width 4.500 ftഀ Support Shearsഀ Shear @ Leftഀ 24.72 kഀ Shear @ Rightഀ 24.72 kഀ Section Propertiesഀ Section Nameഀ W14X26ഀ Depthഀ 13.910 inഀ Ixx : Steel Sectionഀ 245.00 in4ഀ Widthഀ 5.025 inഀ I transformedഀ 801.82 in4ഀ Flange Thickഀ 0.420 inഀ Strans : topഀ 185.34 in3ഀ Web Thickഀ 0.255 inഀ Strans : botഀ 56.93 in3ഀ Areaഀ 7.690 in2ഀ Strans : eff @ botഀ 46.57 in3ഀ Weightഀ 26.121 #/ftഀ n*Strans : Ef @ topഀ 977.6 in3ഀ I-steelഀ 245.00 in4ഀ X-X Axis from Botഀ 14.08 inഀ S steel : topഀ 35.23 in3ഀ Vh @ 100%ഀ 192.25 kഀ S steel : bottomഀ 35.23 in3ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 6:46AM, 15 DEC 05ഀ Description : Lodge Expansionഀ Scope :ഀ Composite Steel Beamഀ Page 2ഀ 5500.ecw:8182 h--ഀ ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 6:09AM, 15 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Scopeഀ Rev: 580007ഀ User: KW-0606238, ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Page 1ഀ 5500.ecw:8182 beamsഀ Descriptionഀ Floor Beam - FB26ഀ General Informationഀ Code Ref: AisC stn ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Load Duration Factor 1.00ഀ Spans Considered Contiഀ nuous Over Supportsഀ Span Informationഀ Descriptionഀ L Spanഀ Mid Spanഀ R Spanഀ Span ftഀ Iഀ 18.00ഀ 8.50ഀ 8.50ഀ Steel Sectionഀ W14X26ഀ W14X26ഀ W14X26ഀ End Fixityഀ Pin-Pinഀ Pin-Pinഀ Pin-Pinഀ Unbraced Length ftഀ Iഀ 5.00ഀ 5.00ഀ 5.00ഀ Loadsഀ uഀ Live Load Used Thisഀ Span?ഀ Yesഀ Yesഀ Yesഀ Dead Load k/ftഀ 1.120ഀ 1.120ഀ 1.120ഀ Live Load k/ftഀ 1.600ഀ 1.600ഀ 1ഀ 600ഀ Point #1 DL kഀ 8.480ഀ .ഀ 4.780ഀ LL kഀ 13.930ഀ 7.490ഀ @ X ftഀ 7.500ഀ 3.000ഀ Resultsഀ -ഀ ഀ Mmax @ Cntr k-ftഀ jഀ 72.75ഀ 0.00ഀ 31.93ഀ @ X = ftഀ 7.32ഀ 0.00ഀ 3.63ഀ Max @ Left End k-ftഀ 0.00ഀ -82.55ഀ -23.04ഀ Max @ Right End k-ftഀ -82.55ഀ -23.04ഀ 0.00ഀ fb : Actual psi Iഀ 28,122.4ഀ 28,122.4ഀ 10,877.7ഀ Fb : Allowable psiഀ 30,000.0ഀ 30,000.0ഀ 30,000.0ഀ fv : Actualഀ Bending OKഀ Bending OKഀ Bending OKഀ psiഀ 8,194.5ഀ 6,859.7ഀ 6ഀ 261.5ഀ Fv : Allowable psiഀ 20,000.0ഀ 20,000.0ഀ ,ഀ 20,000.0ഀ Reactions & Deflectionsഀ 0._:..ഀ ഀ Shear @ Left kഀ 19.89ഀ 21.20ഀ 22.21ഀ Shear @ Right kഀ 29.07ഀ 24.33ഀ 13.18ഀ Reactions...ഀ DL @ Left kഀ 8.19ഀ 20.66ഀ 18.21ഀ LL @ Left kഀ 11.70ഀ 29.60ഀ 28.33ഀ Total @ Left kഀ 19.89ഀ 50.26ഀ 46.54ഀ DL @ Right kഀ 20.66ഀ 18.21ഀ 5ഀ 39ഀ LL @ Right k iഀ 29.60ഀ 28.33ഀ .ഀ 7.79ഀ Total @ Right kഀ 50.26ഀ 46.54ഀ 13.18ഀ Max. Deflection inഀ Iഀ 0.504ഀ 0.051ഀ -0.053ഀ @ X= ftഀ 8.16ഀ 3.06ഀ 4.31ഀ Span/Deflection Ratioഀ 428.4ഀ 1,981.6ഀ 1,910.9ഀ Query Valuesഀ Location ftIഀ 0.00 0.00ഀ 0.00ഀ 0.00 0.00ഀ 0ഀ 00 0ഀ 00ഀ 0ഀ 00ഀ Shearഀ kഀ Moment k-ft 1ഀ 19.89ഀ -0ഀ 00ഀ 21.20ഀ -82ഀ 55ഀ 22.21ഀ -23ഀ 04ഀ .ഀ .ഀ 0.00 0.00 0.00 0.00ഀ .ഀ 0.00ഀ Max. Deflection in!ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ .ഀ 0.0000ഀ 0.00 0.00 0.00 0.00ഀ 0.0000 0.0000 0.0000 0.0000ഀ 0.00ഀ 0.0000ഀ C-.►r'~~ 1~. _ _ _ ~ i - - _ I g,d-Icy ~1~~0 ~ 1 ~ ~,.~1t IIഀ "A l -ഀ S -ഀ ഀ ഀ tMAഀ - rl ,.kt~ t do NWn"10'~ _ - _ nഀ -low n -1Ooഀ - -ld law 1„tdpd NpP a1ISodW _ _ \ 1] 9~`{7 -ഀ ~1~~7N0 7ഀ 40ഀ 4,141ഀ VIX _ഀ ~ ttl - pC Z►M ~t - ~ O _ഀ 0 t400ഀ ti p Xt~ഀ ഀ s„yഀ 143 91XZIM LL'L DnX -ഀ Fzഀ L¢.ഀ ObX I S?JI`dl5ഀ ;312Z17N07ഀ q W ~7`d1dഀ NI LGV'D ~ഀ 91XZ► ~ 1 I ,1•ഀ M_ഀ do ,y IQIQ) V-91ഀ 71bg"i's(~fഀ ld 3 ,4ഀ .IlyIX~ 00 ~Z. ~ a~c_.t - ~ഀ A, -V Iഀ I 1,1...:....:ഀ ~ - ~ I I _ ~5H '•9 •.r.~: •..i i anഀ i ~ ~ . t ~M I` ~j:::':•~.~:::::. M • : ~ may.;:: ~ •....r::::: - ~lഀ -maഀ do g/~ ~ o~L~' • ~ ~:+,i~'9►', ~ ~ഀ -ally 3 I A~ 9lXZIM ~b cLഀ d,gഀ 9'd1S dH '~l3 y i8ts31•ഀ ~~~N It S ' L Zഀ 9/N~ dp d01 2'b1 ~~►Idl C~.':: • : w t\ഀ 1ഀ ,.pl-,IQIQ bX 1 rഀ .1i .9 anഀ ~4t~ ~ ....-tii~l:•~•~•'~': 1 ~-,lug)ഀ ഀ .160ഀ lavA oilഀ canഀ 1 7 ~ o - ~ 1 `gyp Xഀ h plXtd►°I~ O~ r I.IQഀ ry ~ 1 Iഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.6.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983.2003 ENERCALC Enqineerinq Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FBI 01ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X22 Fy 50.00 ksiഀ Beam Span 19.000 ft f'c 3,500.00 psiഀ Beam Spacing 8.000 ft Concrete Density 145.00 pcfഀ Slab Thickness 4.500 in Stud Diameter 0.750 inഀ Deck Rib Height 1.500 in Stud Height 3.000 inഀ Rib Spacing 6.000 in Beam Weight Added Internallyഀ Rib Width 1.750 in Using Partial Composite Actionഀ Rib Orientation Perpendicular Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.320 k/ft # 1 4.850 k 16.000ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.360 k/ft @ Right 0.360 k/ft 16.000 19.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ # 1 0.560 k/ft # 1 15.240 k 16.000 ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.480 k/ft @ Right 0.480 k/ft 16.000 19.000 ftഀ Sumഀ Using: W 12X22, Span = 19.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 27,487.5 psi Allowable =ഀ Unshored DL Stress Actual = 11,636.1 psi Allowable =ഀ Actual Shear Stress Actual = 8,688.4 psi Allowable =ഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 30,724.7 psi Allowable =ഀ MII / Strans(top) Actual = 494.7 psi Allowable =ഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 37,415.6ഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top * n) 712.3ഀ OK Shored & Unshoredഀ 6.00in, Rib Width= 1.75in w/ Slab Eഀ 33,333.0 psi OKഀ 33,333.0 psi OKഀ 20,000.0 psi OKഀ 45,000.0 psi OKഀ 1,575.0 psi OKഀ 38,000.0 psiഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 40.50 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 162.00k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 4.433 ft , Useഀ 1 studsഀ Zone 2 fromഀ 4.433 ftഀ toഀ 8.867 ft , Useഀ 2 studsഀ Zone 3 fromഀ 8.867 ftഀ toഀ 13.300 ft , Useഀ 0 studsഀ Zone 4 fromഀ 13.300 ftഀ toഀ 15.200 ft , Useഀ 0 studsഀ Zone 5 fromഀ 15.200 ftഀ toഀ 17.100 ft , Useഀ 2 studsഀ Zone 6 fromഀ 17.100 ftഀ toഀ 19.000 ft , Useഀ 1 studsഀ I-, ~ a Jഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ j 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB101ഀ Deflectionsഀ I : Transformedഀ 581.78 in4 Iഀ : Effective 360.00n4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.155 in (after shores removed)ഀ 0.358 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.332 inഀ 0.332 inഀ Total Uncured Deflectionഀ 0.155 in L/1471.5ഀ 0.358 in L / 637.7ഀ Composite Deflectionഀ 0.487 in L / 468.0ഀ 0.690 in L / 330.6ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 4.10 kഀ 8.33 kഀ Compositeഀ 7.84 kഀ 19.48 kഀ Max DL + LLഀ 11.94 kഀ 27.81 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 24.58 k-ft Fb : Allowഀ 33.00 psiഀ Based on Beam Span 4.750 ftഀ Dead + Constഀ 24.58 k-ft n : Strengthഀ 8.60ഀ Based on Beam Spacing 8.000 ftഀ Live Load Onlyഀ 54.88 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 79.03 k-ftഀ Effective Width 4.750 ftഀ Support Shearsഀ Shear @ Leftഀ 11.94 kഀ Shear @ Rightഀ 27.81 kഀ Section Propertiesഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 580.54 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 154.80 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 44.45 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 34.50 in3ഀ Weightഀ 22.011 #/ftഀ n'Strans : Ef @ topഀ 751.4 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 13.06 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 162.00 kഀ S steel : bottomഀ 25.35 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB102ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X19 Fy 50.00 ksiഀ Beam Span 19.000 ft f'c 3,500.00 psiഀ Beam Spacing 5.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpenഀ dicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.350 k/ftഀ # 1 4.850 k 16.000ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.180 k/ftഀ @ Rightഀ 0.180 k/ft 16.000 19.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.200 k/ft # 1 15.240 k 16.000 ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.240 k/ft @ Right 0.240 k/ft 16.000 19.000 ftഀ Summaryഀ Using: W1 2X1 9, Span = 19.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 26,384.1 psi Allowable =ഀ Unshored DL Stress Actual = 14,150.3 psi Allowable =ഀ Actual Shear Stress Actual = 8,217.8 psi Allowable =ഀ Unshored Stress Check.... .ഀ (Mdl/Ss + MII/Strans) Actual = 31,762.9 psi Allowable =ഀ MII / Strans(top) Actual = 426.7 psi Allowable =ഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 37,130.1ഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n) 639.1ഀ OK Shored & Unshoredഀ 6.00in, Rib Width= 1.75in w/ Slab Eഀ 33,333.0 psi OKഀ 33,333.0 psi OKഀ 20,000.0 psi OKഀ 45,000.0 psi OKഀ 1,575.0 psi OKഀ 38,000.0 psiഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 34.81 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 139.25k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 5.067 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 5.067 ftഀ toഀ 10.133 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 10.133 ftഀ toഀ 15.200 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 15.200 ftഀ toഀ 16.467 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 16.467 ftഀ toഀ 17.733 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 17.733 ftഀ toഀ 19.000 ftഀ , Useഀ 1 studsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pa e 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam gഀ (61983-2003 ENERCALC Enaineerina Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB102ഀ Deflectionsഀ _z _ - -ഀ -L" M__ഀ I : Transformed 504.66 in4 I : Effective 323.61in4ഀ Shored Unshoredഀ Before 75 % Curing 0.177 in (after shores removed) 0.442 inഀ Construction Loads Only 0.000 in 0.000 inഀ After 75% Curing 0.254 in 0.254 inഀ Total Uncured Deflection 0.177 in L / 1285.2 0.442 in L / 516.3ഀ Composite Deflection 0.431 in L / 529.4 0.695 in L / 328.0ഀ Reactionsഀ Load Combinations... @ Left @ Rightഀ Dead + Constuction 4.31 k 8.09 kഀ Composite 4.36 k 15.40 kഀ Max DL + LL 8.68 k 23.48 kഀ Analysis Valuesഀ 9ഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 25.21 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 4.750 ftഀ Dead + Constഀ 25.21 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 5.000 ftഀ Live Load Onlyഀ 44.16 k-ft n : Deflectionഀ 8.51ഀ Dead , Liveഀ 66.16 k-ftഀ Effective Width 4.750 ftഀ Support Shearsഀ Shear @ Leftഀ 8.68 kഀ Shear @ Rightഀ 2148 kഀ Section Propertiesഀ Section Nameഀ W12X19ഀ Depthഀ 12.160 inഀ Ixx : Steel Sectionഀ 130.00 in4ഀ Widthഀ 4.005 inഀ I transformedഀ 503.65 in4ഀ Flange Thickഀ 0.350 inഀ Strans : topഀ 144.44 in3ഀ Web Thickഀ 0.235 inഀ Strans : botഀ 38.23 in3ഀ Areaഀ 5.570 in2ഀ Strans : eff @ botഀ 30.09 in3ഀ Weightഀ 18.920 #/ftഀ n'Strans : Ef @ topഀ 730.8 in3ഀ I-steelഀ 130.00 in4ഀ X-X Axis from Botഀ 13.17 inഀ S steel : topഀ 21.38 in3ഀ Vh @ 100%ഀ 139.25 kഀ S steel : bottomഀ 21.38 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 3' 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 8:50AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Enqineerina Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB103ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X40 Fy 50.00 ksiഀ Beam Span 24.000 ft f'c 3,500.00 psiഀ Beam Spacing 4.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ n..ഀ -ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.560 k/ftഀ # 1 5.950 k 5.000ftഀ # 2 k/ftഀ # 2 6.680 k 5.000ftഀ # 3 k/ftഀ # 3 4.060 k 21.000 ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.360 k/ftഀ @ Rightഀ 0.360 k/ft 21.000 24.000 ftഀ Llve LOadS (applied after 75% curing)ഀ Full Span Uniform Loadsഀ Point Loads...ഀ # 1 0.320 k/ftഀ # 2 k/ftഀ # 3 k/ftഀ Trapezoidal Loads...ഀ # 1 , @ Left 0.480 k/ftഀ # 2 @ Left 0.480 k/ftഀ #1ഀ #2ഀ #3ഀ @ Right 0.480 k/ft ;ഀ @ Right 0.480 k/ftഀ 13.630 k 5.000 ftഀ 4.650 k 5.000 ftഀ 13.540 k 21.000 ftഀ 5.000 ftഀ 21.000 24.000 ftഀ uuin~c~~ഀ Overstressedഀ Using: W12X40, Span = 24.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 35,514.3 psiഀ Allowable = 33,333.0 psi NGഀ Unshored DL Stress Actual =ഀ 19,882.4 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 11,361.6 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 39,311.8 psiഀ MII / Strans(top) Actual = 839.2 psiഀ Alternate Unshored Stress Check : (Mdl + VIII) / Ssഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n)ഀ Allowable =ഀ 45,000.0 psi OKഀ Allowable =ഀ 1,575.0 psi OKഀ 43,172.6ഀ 38,000.0 psiഀ 1,533.9ഀ 1,575.0 psiഀ i Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 8:50AM, 14 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ F : 580001ഀ r: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ 983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB103ഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 75.99 kഀ Total req'd 1/2 Span 7studs Vh @ 100% 214.20k Vh : Used 37.19 kഀ Zone 1 from 0.000 ftഀ toഀ 2.453 ftഀ , Useഀ 1 studsഀ Zone 2 from 2.453 ftഀ toഀ 4.907 ftഀ , Useഀ 2 studsഀ Zone 3 from 4.907 ftഀ toഀ 7.360 ftഀ , Useഀ 0 studsഀ Zone 4 from 7.360 ftഀ toഀ 12.907 ftഀ , Useഀ 0 studsഀ Zone 5 from 12.907 ftഀ toഀ 18.453 ftഀ , Useഀ 2 studsഀ Zone 6 from 18.453 ftഀ toഀ 24.000 ftഀ , Useഀ 1 studsഀ Deflectionsഀ I : Transformed 879.13 in4ഀ Iഀ : Effective 545.39in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.571 inഀ (after shores removed)ഀ 1.015 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.678 inഀ 0.678 inഀ Total Uncured Deflectionഀ 0.571 inഀ L / 504.1ഀ 1.015 in L / 283.8ഀ Composite Deflectionഀ 1.250 inഀ L / 230.4ഀ 1.693 in L / 170.1ഀ Reactionsഀ Kഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 17.77 kഀ 14.40 kഀ Compositeഀ 22.24 kഀ 21.10 kഀ Max DL + LLഀ 40.02 kഀ 35.49 kഀ Analysis Valuesഀ lrഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 85.20 k-ft Fb : Allowഀ 33.00 psiഀ Based on Beam Span 6.000 ftഀ Dead + Constഀ 85.20 k-ft n : Strengthഀ 8.60ഀ Based on Beam Spacing 4.000 ftഀ Live Load Onlyഀ 101.22 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 185.01 k-ftഀ Effective Width 4.000 ftഀ Support Shearsഀ Shear @ Leftഀ 40.02 kഀ Shear @ Rightഀ 35.49 kഀ Section Propertiesഀ Section Nameഀ W12X40ഀ Depthഀ 11.940 inഀ Ixx : Steel Sectionഀ 307.00 in4ഀ Widthഀ 8.005 inഀ I transformedഀ 876.51 in4ഀ Flange Thickഀ 0.515 inഀ Strans : topഀ 168.30 in3ഀ Web Thickഀ 0.295 inഀ Strans : botഀ 78.04 in3ഀ Areaഀ 11.800 in2ഀ Strans : eff @ botഀ 62.51 in3ഀ Weightഀ 40.081 #/ftഀ n`Strans : Ef @ topഀ 861.0 in3ഀ I-steelഀ 307.00 in4ഀ X-X Axis from Botഀ 11.23 inഀ S steel : topഀ 51.42 in3ഀ Vh @ 100%ഀ 214.20 kഀ S steel : bottomഀ 51.42 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 8:50AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ ` Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Pagelഀ (c)1983.2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB104ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X58 Fy 50.00 ksiഀ Beam Span 24.000 ft f'c 3,500.00 psiഀ Beam Spacing 8.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpenഀ dicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.560 k/ftഀ # 1 9.370 kഀ 5.000ftഀ # 2 k/ftഀ # 2 6.680 kഀ 5.000ftഀ # 3 k/ftഀ # 3 6.680 kഀ 5.000 ftഀ # 4 k/ftഀ # 4 2.280 k 21.000ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.360 k/ftഀ @ Rightഀ 0.360 k/ft 21.000ഀ 24.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.320 k/ftഀ # 1ഀ 14.070 kഀ 5.000 ftഀ # 2 k/ftഀ # 2ഀ 4.650 kഀ 5.000 ftഀ # 3 k/ftഀ # 3ഀ 4.650 kഀ 5.000 ftഀ # 4 k/ftഀ # 4ഀ 7.390 kഀ 21.000 ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.480 k/ft @ Rightഀ 0.480 k/ftഀ ഀ 5.000 ftഀ # 2 @ Left 0.480 k/ft @ Rightഀ 0.480 k/ftഀ 21.000ഀ 24.000 ftഀ OK Shored & Unshoredഀ Using: W12X58, Span = 24.00ft, Slab Thickness = 4.5001n, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 31,511.6 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 18,641.7 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 11,681.9 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 34,148.5 psiഀ MII / Strans(top) Actual = 635.2 psiഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top " n)ഀ Allowable =ഀ 45,000.0 psi OKഀ Allowable =ഀ 1,575.0 psi OKഀ 36,703.5ഀ 38,000.0 psiഀ 1,290.8ഀ 1,575.0 psiഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 8:50AM, 14 DEC 05ഀ nev. oouuuiഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB104ഀ Page 2ഀ 5500.ecw:8195 Beamsഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 80.33 kഀ Total req'd 1/2 Span 7studs Vh @ 100% 321.30k Vh : Used 37.19 kഀ Zone 1 from 0.000 ftഀ toഀ 1.707 ftഀ , Useഀ 1 studsഀ Zone 2 from 1.707 ftഀ toഀ 3.413 ftഀ , Useഀ 2 studsഀ Zone 3 from 3.413 ftഀ toഀ 5.120 ftഀ , Useഀ 0 studsഀ Zone 4 from 5.120 ftഀ toഀ 11.413 ftഀ , Useഀ 0 studsഀ Zone 5 from 11.413 ftഀ toഀ 17.707 ftഀ , Useഀ 2 studsഀ Zone 6 from 17.707 ftഀ toഀ 24.000 ftഀ , Useഀ 1 studsഀ Deflectionsഀ I : Transformed 1,336.3ഀ 1 in4ഀ Iഀ : Effective 768.02in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.532 inഀ (after shores removed)ഀ 0.860 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.500 inഀ 0.500 inഀ Total Uncured Deflectionഀ 0.532 inഀ L / 541.5ഀ 0.860 in L / 334.9ഀ Composite Deflectionഀ 1:032 inഀ : L / 279.1ഀ 1.360 in L / 211.8ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Riohtഀ Dead + Constuctionഀ 25.76 kഀ 15.16 kഀ Compositeഀ 25.50 kഀ 16.77 kഀ Max DL + LLഀ 51.27 kഀ 31.93 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 121.07 k-ft Fb : Allowഀ 33.00 psi Based on Beam Spanഀ 6.000 ftഀ Dead + Constഀ 121.07 k-ft n : Strengthഀ 8.60 Based on Beam Spacingഀ 8.000 ftഀ Live Load Onlyഀ 117.30 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 238.37 k-ftഀ Effective Widthഀ 6.000 ftഀ Support Shearsഀ Shear @ Leftഀ 51.27 kഀ Shear @ Rightഀ 31.93 kഀ Section Propertiesഀ Section Nameഀ W12X58ഀ Depthഀ 12.190 inഀ Ixx : Steel Sectionഀ 475.00 in4ഀ Widthഀ 10.010 inഀ I transformedഀ 1,332.45 in4ഀ Flange Thickഀ 0.640 inഀ Strans : topഀ 257.67 in3ഀ Web Thickഀ 0.360 inഀ Strans : botഀ 115.68 in3ഀ Areaഀ 17.000 in2ഀ Strans : eff @ botഀ 90.77 in3ഀ Weightഀ 57.744 #/ftഀ n*Strans : Ef @ topഀ 1,196.1 in3ഀ I-steelഀ 475.00 in4ഀ X-X Axis from Botഀ 11.52 inഀ S steel : topഀ 77.93 in3ഀ Vh @ 100%ഀ 321.30 kഀ S steel : bottomഀ 77.93 in3ഀ i-r5(i~ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Enoineerino Software 55oo.ecw:8195 Beamsഀ Description Floor Beam - FB105ഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X22 Fy 50.00 ksiഀ Beam Span 15.500 ft f'c 3,500.00 psiഀ Beam Spacing 12.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Botഀ h Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.840 k/ftഀ # 1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.200 k/ftഀ # 2 0.400 k/ftഀ #1 kഀ #2 kഀ ftഀ ftഀ Summary OK Shored & Unshoredഀ Using: W1 2X22, Span = 15.50ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Eഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 15,092.5 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 12,256.6 psiഀ Allowable = 33,333.0 psi; OKഀ Actual Shear Stress Actual =ഀ 3,540.1 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 18,450.5 psiഀ Allowable = 45,000.0 psi OKഀ Mill / Strans(top) Actual = 184.1 psiഀ Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 20,787.8 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n)ഀ 448.7 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 40.50 kഀ Total req'd 1/2 Span 5 studs Vh @ 100% 162.00k Vh : Used 43.75 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.583 ft , Useഀ 2 studsഀ Zone 2 fromഀ 2.583 ftഀ toഀ 5.167 ft , Useഀ 2 studsഀ Zone 3 fromഀ 5.167 ftഀ toഀ 7.750 ft , Useഀ 1 studsഀ Zone 4 fromഀ 7.750 ftഀ toഀ 10.333 ft , Useഀ 1 studsഀ Zone 5 fromഀ 10.333 ftഀ toഀ 12.917 ft , Useഀ 2 studsഀ Zone 6fromഀ 12.917 ftഀ toഀ 15.500 ft , Useഀ 2 studsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ " 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ `zഀ Rev: 580001 Pa I 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam gഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB105ഀ Deflectionsഀ I : Transformedഀ 558.28 in4ഀ I : Effective 365.05in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.106 inഀ (after shores removed) 0.247 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.074 inഀ 0.074 inഀ Total Uncured Deflectionഀ 0.106 inഀ L / 1759.8 0.247 in L / 752.0ഀ Composite Deflectionഀ 0.179 inഀ L / 1037.1 0.321 in L / 579.6ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 6.68 kഀ 6.68 kഀ Compositeഀ 4.65 kഀ 4.65 kഀ Max DL + LLഀ 11.33 kഀ 11.33 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 25.89 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 3.875 ftഀ Dead + Constഀ 25.89 k-ft n : Strengthഀ 8.60 Based, on Beam Spacing 12.000 ftഀ Live Load Onlyഀ 18.02 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 43.91 k-ftഀ Effective Width 3.875 ftഀ Support Shearsഀ Shear @ Leftഀ 11.33 kഀ Shear @ Rightഀ 11.33 kഀ Section Propertiesഀ Eഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 556.98 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 136.55 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 43.75 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 34.91 in3ഀ Weightഀ 22.011 #/ftഀ n*Strans : Ef @ topഀ 714.9 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 12.73 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 162.00 kഀ S steel : bottomഀ 25.35 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ ' 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB106ഀ Design Input Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 111ഀ Section Name W12X22 Fy 50.00 ksiഀ Beam Span 8.000 ft f'c 3,500.00 'psiഀ Beam Spacing 15.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab Both Sidesഀ Dead Loadsഀ ( applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1ഀ 1.050 k/ftഀ # 1 k ftഀ Live Loadsഀ (applied afterഀ 75% curing)ഀ s - _ - _ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1ഀ 0.400 k/ftഀ # 1 k ftഀ # 2ഀ 0.500 k/ftഀ # 2 k ftഀ Summary OK Shored & Unshoredഀ Using: W 12X22, Span= 8.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Bഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 5,595.6 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 4,060.4 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 2,464.6 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 6,614.2 psiഀ Allowable =ഀ 45,000.0 psi OKഀ MII / Strans(top) Actual = 114.1 psiഀ Allowable =ഀ 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 7,469.4ഀ 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n)ഀ 250.0ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 30.68 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 122.72k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.333 ftഀ , Useഀ 2 studsഀ Zone 2 fromഀ 1.333 ftഀ toഀ 2.667 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 2.667 ftഀ toഀ 4.000 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 4.000 ftഀ toഀ 5.333 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 5.333 ftഀ toഀ 6.667 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 6.667 ftഀ toഀ 8.000 ftഀ , Useഀ 2 studsഀ t Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ sഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Page 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ 77' 0_775ഀ Description Floor Beam - FB106ഀ Deflectionsഀ I : Transformedഀ 473.55 in4ഀ I : Effective 325.5Ein4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.010 in (after shores removed)ഀ 0.022 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.009 inഀ 0.009 inഀ Total Uncured Deflectionഀ 0.010 in L/9179.3ഀ 0.022 in L / 4398.1ഀ Composite Deflectionഀ 0.019 in L /4987.9ഀ 0.031 in L / 3136.5ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 4.29 kഀ 4.29 kഀ Compositeഀ 3.60 kഀ 3.60 kഀ Max DL + LLഀ 7.89 kഀ 7.89 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 8.58 k-ft Fb : Allowഀ •33.00 psi Based on Beam Span 2.000 ftഀ Dead + Constഀ 8.58 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 15.000 ftഀ Live Load Onlyഀ 7.20 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 15.78 k-ftഀ Effective Width 2.000 ftഀ Support Shearsഀ Shear @ Leftഀ 7.89 kഀ Shear @ Rightഀ 7.89 kഀ Section Propertiesഀ r4ഀ Section Nameഀ W1 2;22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 472.10 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 88.05 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 41.24 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 33.83 in3ഀ Weightഀ 22.011 #/ftഀ n`Strans : Ef @ topഀ 505.9 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 11.45 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 122.72 kഀ S steel : bottomഀ 25.35 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 9:01AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Very-8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB107ഀ Design Inputഀ Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X22ഀ Fy 50.00 ksiഀ Beam Spanഀ 8.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 15.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 1.050 k/ftഀ #1 10.570 k 7.000ftഀ Llve Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.600 k/ft # 1 18.540 k 7.000 ftഀ OK Shored & Unshoredഀ Using: W 12X22, Span = 8.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Bഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 11,311.2 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 6,948.2 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 10,047.9 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 13,444.5 psiഀ MII / Strans(top) Actual = 290.3 psiഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss .ഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top ' n)ഀ Allowable =ഀ 45,000.0 psi OKഀ Allowable =ഀ 1,575.0 psi OKഀ 15,098.9ഀ 38,000.0 psiഀ 505.4ഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 30.68 kഀ Total req'd 1/2 Span 4studs Vh @ 100% 122.72k Vh : Used 35.00 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.062 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 2.062 ftഀ toഀ 4.124 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 4.124 ftഀ toഀ 6.187 ftഀ , Useഀ 1 studsഀ Zone 4 fromഀ 6.187 ftഀ toഀ 6.791 ftഀ , Useഀ 1 studsഀ Zone 5 fromഀ 6.791 ftഀ toഀ 7.396 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 7.396 ftഀ toഀ 8.000 ftഀ , Useഀ 2 studsഀ I°r~llഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ (l 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 9:01AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pageഀ 2ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Enaineerina Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB107ഀ Deflectionsഀ I : Transformedഀ 473.55 in4ഀ I : Effective 325.5~in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.018 in (after shores removed)ഀ 0.038 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.019 inഀ 0.019 inഀ Total Uncured Deflectionഀ 0.018 in L/5302.4ഀ 0.038 in L / 2540.6ഀ Composite Deflectionഀ 0.037 in L / 2563.4ഀ 0.057 in L / 1680.1ഀ Reactionsഀ rvഀ Load Combinations...ഀ Leftഀ @ഀ @ Rightഀ Dead + Constuctionഀ 5.61 k •ഀ 13.54 kഀ Compositeഀ 4.72 kഀ 18.62 kഀ Max DL + LLഀ 10.33 kഀ 32.16 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 14.68 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 2.OOOftഀ Dead + Constഀ 14.68 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 15.000 ftഀ Live Load Onlyഀ 18.32 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 31.89 k-ftഀ Effective Width 2.000ftഀ Support Shearsഀ Shear @ Leftഀ 10.33 kഀ Shear @ Rightഀ 32.16 kഀ Section Propertiesഀ Section Nameഀ W12X22ഀ Depthഀ 12.310 inഀ Ixx : Steel Sectionഀ 156.00 in4ഀ Widthഀ 4.003 inഀ I transformedഀ 472.10 in4ഀ Flange Thickഀ 0.425 inഀ Strans : topഀ 88.05 in3ഀ Web Thickഀ 0.260 inഀ Strans : botഀ 41.24 in3ഀ Areaഀ 6.480 in2ഀ Strans : eff @ botഀ 33.83 in3ഀ Weightഀ 22.011 #/ftഀ n'Strans : Ef @ topഀ 505.9 in3ഀ I-steelഀ 156.00 in4ഀ X-X Axis from Botഀ 11.45 inഀ S steel : topഀ 25.35 in3ഀ Vh @ 100%ഀ 122.72 kഀ S steel bottomഀ 25.35 in3ഀ \:bഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ j 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB108ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14ഀ 59M -1 1ഀ Fy 50.00 ksiഀ Beam Spanഀ 15.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 8.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpenഀ dicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Both Sidesഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.560 k/ftഀ #1 k 13.000ftഀ Trapezoidal Loads...ഀ #1 @ Left 0.180 k/ftഀ @ Rightഀ 0.180 k/ft 13.000 15.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.320 k/ft # 1 k ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.240 k/ft @ Right 0.240 k/ft 13.000 15.000 ftഀ immaryഀ Using: W 12X14, Span = 15.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 13,525.3 psi Allowable =ഀ Unshored DL Stress Actual = 13,168.8 psi Allowable =ഀ Actual Shear Stress Actual = 3,144.4 psi Allowableഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 18,057.5 psi Allowable =ഀ MII / Strans(top) Actual = 119.6 psi Allowable =ഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 20,622.2ഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n) 330.8ഀ OK Shored & Unshoredഀ 6.00in, Rib Width= 1.75in w/ Slab Eഀ 33,333.0 psi OKഀ 33,333.0 psi OKഀ 20,000.0 psi OKഀ 45,000.0 psi OKഀ 1,575.0 psi OKഀ 38,000.0 psiഀ 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3studs Vh @ 100% 104.00k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.533 ft , Useഀ 1 studsഀ Zone 2 fromഀ 2.533 ftഀ toഀ 5.067 ft , Useഀ 2 studsഀ Zone 3 fromഀ 5.067 ftഀ toഀ 7.600 ft , Useഀ 0 studsഀ Zone 4 fromഀ 7.600 ftഀ toഀ 10.067 ft , Useഀ 0 studsഀ Zone 5 fromഀ 10.067 ftഀ toഀ 12.533 ft , Useഀ 2 studsഀ Zone 6 fromഀ 12.533 ftഀ toഀ 15.000 ft , Useഀ 1 studsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ i' 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pa e 2ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beam gഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB108ഀ Deflectionsഀ I : Transformedഀ 364.81 in4 Iഀ : Effective 253.77in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.090 in (after shores removed)ഀ 0.258 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.051 inഀ 0.051 inഀ Total Uncured Deflectionഀ 0.090 in L/2000.0ഀ 0.258 in L / 698.3ഀ Composite Deflectionഀ 0.141 in L / 1275.5ഀ 0.309 in L / 582.8ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuction •ഀ 4.33 kഀ 4.64 kഀ Compositeഀ 2.43 kഀ 2.85 kഀ Max DL + LLഀ 6.76 kഀ 7.49 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 16.33 k-ft Fb : Allowഀ 33.00 psi Based on -Beam Span 3.750 ftഀ Dead + Constഀ 16.33 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 8.000 ftഀ Live Load Onlyഀ 9.24 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 25.57 k-ftഀ Effective Width 3.750 ftഀ Support Shearsഀ Shear @ Leftഀ 6.76 kഀ Shear @ Rightഀ 7.49 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 364.09 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 107.85 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 27.93 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 22.68 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 606.0 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 13.03 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 104.00 kഀ S steel : bottomഀ 14.88 in3ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ ' Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ Mev. Jov~VIഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB109ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 13.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 13.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Is (applied before 75% curing)ഀ _ rഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.455 k/ftഀ #1 0.780 k 4.000ftഀ #2 k/ftഀ # 2 0.780 k 12.000ftഀ Trapezoidal Loads...ഀ #1 @ Left 0.173 k/ftഀ @ Rightഀ 0.173 k/ft 4.000 12.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.260 k/ftഀ #1 2.630 k 4.000 ftഀ #2 k/ftഀ # 2 2.630 k 12.000 ftഀ Trapezoidal Loads...ഀ #1 @ Left 0.400 k/ftഀ @ Rightഀ 0.400 k/ft 4.000 12.000 ftഀ aഀ OK Shored & Unshoredഀ Using: W12X14, Span = 13.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 19,619.1 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 11,924.1 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 4,935.8 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 22,948.7 psiഀ Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 419.8 psiഀ Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ssഀ 27,162.0 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n)ഀ 747.1 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 24.93 kഀ Total req'd 1/2 Span 3 studs Vh @ 100% 99.71 k Vh : Used 26.25 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.051 ft , Useഀ 1 studsഀ Zone 2 fromഀ 2.051 ftഀ toഀ 4.102 ft , Useഀ 2 studsഀ Zone 3 fromഀ 4.102 ftഀ toഀ 6.153 ft , Useഀ 0 studsഀ Zone 4 fromഀ 6.153 ftഀ toഀ 8.436 ft , Useഀ 0 studsഀ Zone 5 fromഀ 8.436 ftഀ toഀ 10.718 ft , Useഀ 2 studsഀ Zone 6 fromഀ 10.718 ftഀ toഀ 13.000ft , Useഀ 1 studsഀ F3itqഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ User: K0-0606238, Val 5.8.0, 1-Dec-2003ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB109ഀ Composite Steel Beam Page 2ഀ Composite 5500.acw:8195 Beamsഀ Deflectionsഀ I : Transformedഀ 302.96 in4ഀ I : Effective 198.5&in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.078 in (after shores removed)ഀ 0.176 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.101 inഀ 0.101 inഀ Total Uncured Deflectionഀ 0.078 in L/1991.7ഀ 0.176 in L / 888.6ഀ Composite Deflectionഀ 0.179 in L / 870.2ഀ 0.276 in L / 564.3ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 4.18 kഀ 4.86 kഀ Compositeഀ 4.94 kഀ 6.90 kഀ Max DL + LLഀ 9.13 kഀ 11.76 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 14.78 k-ft Fb : Allowഀ 33:00 psi Based on Beam Span 1.625 ftഀ Dead + Constഀ 14.78 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 6.500 ftഀ Live Load Onlyഀ 18.92 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 33.68 k-ftഀ Effective Width i.625ftഀ Support Shearsഀ Shear @ Leftഀ 9.13 kഀ Shear @ Rightഀ 11.76 kഀ Section Propertiesഀ -Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 302.09 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 62.90 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.03 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 20.60 in3ഀ Weightഀ 14.130 #/ftഀ n*Strans : Ef @ topഀ 339.8 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 11.61 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 99.71 kഀ S steel : bottomഀ 11 4.88 in3ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ I, 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ #1ഀ #2ഀ #3ഀ ReV: 580001ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB110ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14 Fy 50.00 ksiഀ Beam Span 13.000 ft f'c 3,500.00 psiഀ Beam Spacing 4.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Perpenഀ dicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab Onഀ e Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.280 k/ftഀ # 1 0.710 k 3.500ftഀ # 2 k/ftഀ # 2 0.710 k 9.500ftഀ # 3 k/ftഀ # 3 1.110 k 13.000 ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.173 k/ftഀ @ Rightഀ 0.173 k/ft 3.500 9.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ # 1 0.160 k/ftഀ # 2 k/ftഀ # 3 k/ftഀ Trapezoidal Loads...ഀ # 1 @ Left 0.150 k/ftഀ @ Right 0.150 k/ftഀ kZഀ Job # 5500.02ഀ Date: 9:38AM, 14 DEC 05ഀ 3.500 9.000 ftഀ Summary OK Shored & Unshoredഀ Using: W12X14, Span = 13.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 13,223.9 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 8,978.1 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 4,750.3 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + Mll/Strans) Actual = 16,195.8 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 303.9 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 19,756.7 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top * n) 556.8 1,575.0 psiഀ Shear Studs & Shear Train sferഀ Actual # Studs 3 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 21.75 kഀ Total req'd 1/2 Span 2 studs Vh @ 100% 87.02k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 2.196 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 2.196 ftഀ toഀ 4.391 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 4.391 ftഀ toഀ 9.587 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 6.587 ftഀ toഀ 8.724 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 8.724 ftഀ toഀ 10.862 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 10.862 ftഀ toഀ 13.000 ftഀ , Useഀ 1 studsഀ 2.100 k 3.500 ftഀ 2.100 k 9.000 ftഀ 3.670 k 13.000 ftഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 9:38AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ (c)1983-2003 ENERCALC Enqineerinq Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB110ഀ Deflectionsഀ I : Transformedഀ 301.61 in4ഀ I : Effective 227.85n4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.051 in (after shores removed)ഀ 0.132 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.063 inഀ 0.063 inഀ Total Uncured Deflectionഀ 0.051 in L / 3032.6ഀ 0.132 in L/ 1179.2ഀ Composite Deflectionഀ 0.115 in L / 1360.1ഀ 0.196 in L / 797.9ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 3.12 kഀ 4.19 kഀ Compositeഀ 3.65 kഀ 7.13 kഀ Max DL + LLഀ 6.77 kഀ 11.32 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 11.13 k-ft Fb : Allowഀ 33.00 psi Based on Beam Span 1.625 ftഀ Dead + Constഀ 11.13 k-ft n : Strengthഀ 8.60 Based on Beam Spacing 2.000 ftഀ Live Load Onlyഀ 13.37 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 24.50 k-ftഀ Effective Width 1.625 ftഀ Support Shearsഀ Shear @ Leftഀ 6.77 kഀ Shear @ Rightഀ 11.32 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 300.71 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 61.39 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 26.12 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 22.23 in3ഀ Weightഀ 14.130 #/ftഀ n*Strans : Ef @ topഀ 389.4 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 11.51 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 87.02 kഀ S steel : bottomഀ 14.88 1 n3ഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 9:38AM, 14 DEC 05ഀ Denver, CO 80202ഀ Description : Lodge Expansionഀ "ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Steel Beamഀ Page 1ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ 5500.ecw:8195 Beamsഀ Iഀ Descriptionഀ Floor Beam - FB110 - Non compഀ General Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy - Yield Stress 50.00 ksi Load Duration Factor 1.00ഀ Spans Considered Continuous Over Supportsഀ Span Informationഀ Description Cant spanഀ Span ft 3.00 10.00ഀ Steel Section w12X14 w12X14ഀ End Fixity Free-Pin Pin-Pinഀ Unbraced Length ft 3.00 0.50ഀ Loadsഀ Live Load Used This Span ?ഀ Yes Yesഀ Dead Load k/ftഀ 0.280 0.280ഀ Live Load k/ftഀ 0.160 0.160ഀ DL @ Left k/ftഀ 0.173ഀ DL @ Right k/ftഀ 0.173ഀ LL @ Left k/ftഀ 0.150ഀ LL @ Right k/ftഀ 0.150ഀ Start ftഀ I 0.500ഀ End ftഀ 6.500ഀ Point #1 DL kഀ 1.110 0.710ഀ LL kഀ I 3.670 2.100ഀ @ X ftഀ 0.500ഀ Point #2 DL kഀ 0.710ഀ LL kഀ 2.100ഀ @ X ftഀ 6.500ഀ Resultsഀ Mmax @ Cntr k-ftjഀ 0.00 8.51ഀ @ X = ftഀ 0.00 6.47ഀ Max @ Left End k-ftഀ 0.00 -16.32ഀ Max @ Right End k-ftഀ -16.32 0.00ഀ fb : Actual psiഀ 13,162.5 13,162.5ഀ Fb : Allowable psiഀ 30,000.0 33,000.0ഀ Bending OK Bending OKഀ fv : Actual psiഀ 2,560.9 3,671.1ഀ Fv : Allowable psiഀ 20,000.0 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 8.74ഀ Shear @ Rightഀ kഀ , 6.10ഀ 3.21ഀ Reactions...ഀ DL @ Leftഀ kഀ 0.00ഀ 5.41ഀ LL @ Leftഀ kഀ 0.00ഀ 9.44ഀ Total @ Leftഀ kഀ 0.00ഀ 14.84ഀ DL @ Rightഀ kഀ 5.41ഀ 1.80ഀ LL @ Rightഀ kഀ 9.44ഀ 1.41ഀ Total @ Rightഀ k:ഀ 14.84ഀ 3.21ഀ Max. Deflectionഀ inഀ 0.047ഀ -0.034ഀ @ X =ഀ ftഀ 0.00ഀ 6.07ഀ Span/Deflection Ratioഀ 1,531.7ഀ 3,547.1ഀ Location ft 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00ഀ Shear k 0.00 8.74 0.00 0.00 0.00 0.00 0.00 0.00ഀ Moment k-ft 0.00 -16.32 0.00 0.00 0.00 0.00 0.00 0.00ഀ Max. Deflection in,l -0.0470 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB111ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W1 2X79ഀ Fy 50.00 ksiഀ Beam Spanഀ 29.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 13.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 k/ftഀ #1 1.110 k 4.000ftഀ #2 k/ftഀ #2 2.610 k 8.000ftഀ #3 k/ftഀ # 3 4.510 k 19.000 ftഀ Trapezoidal Loads...ഀ #1 @ Left 0.420 k/ftഀ @ Rightഀ 0.420 k/ft 4.000 29.000 ftഀ #2 @ Left 0.075 k/ftഀ @ Rightഀ 0.075 k/ft 4.000 19.000 ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 k/ftഀ #1 3.670 k 4.000 ftഀ #2 k/ftഀ # 2 8.710 k 8.000 ftഀ #3 k/ftഀ #3 15.000 k 19.000 ftഀ Trapezoidal Loads...ഀ #1 @ Left 0.240 k/ftഀ @ Rightഀ 0.240 k/ft 4.000 29.000 ftഀ #2 @ Left .0.080 k/ftഀ @ Rightഀ 0.080 k/ft .19.000 26.000 ftഀ #2 @ Left 0.250 k/ftഀ @ Rightഀ 0.250 k/ft 4.000 19.000 ftഀ Summaryഀ No Good Shored, OK Unshored,ഀ Using: W12X79, Span - 29.00ft, Slab Thicknessഀ = 4.500in, Deck Ribഀ Ht= 1.50in, Rib Spac= 6.061n, Rib Width=ഀ 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 25,603.9 psiഀ Allowable = 33,333.0 psiഀ OKഀ Unshored DL Stress Actual =ഀ 10,332.7 psiഀ Allowable = 33,333.0 psiഀ OKഀ Actual Shear Stress Actual =ഀ 5,219.0 psiഀ Allowable = 20,000.0 psiഀ OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 26,908.1 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 1,087.4 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 28,905.0 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n) 1,679.6 1,575.0 psiഀ rrp~ 1- -ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ r 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ z 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pa e 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam gഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB111ഀ Shear Studs & Shear Transferഀ Actual # Studsഀ 3 per 1ഀ /2 beam spanഀ Stud Capacityഀ 8.75 k V'h : minഀ 55.61 kഀ Total req'd 1/2 Spanഀ 7studsഀ Vh @ 100% 222.43k Vh : Usedഀ 26.25 kഀ Zone 1 fromഀ 0.000 ftഀ to 5.736 ftഀ , Use 1 studsഀ Zone 2 fromഀ 5.736 ftഀ to 11.471 ftഀ , Use 2 studsഀ Zone 3 fromഀ 11.471 ftഀ to 17.207 ftഀ , Use 0 studsഀ Zone 4 fromഀ 17.207 ftഀ to 21.138 ftഀ , Use 0 studsഀ Zone 5 fromഀ 21.138 ftഀ to 25.069 ftഀ , Use 2 studsഀ Zone 6 fromഀ 25.069 ftഀ to 29.000 ftഀ , Use 1 studsഀ Deflectionsഀ I : Transformedഀ 1,476.58 in4ഀ I : Effective 941.8,3n4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.513 in (after shores removed) 0.729 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.921 inഀ 0.921 inഀ Total Uncured Deflectionഀ 0.513 in L / 678.9ഀ 0.729 in L / 477.2ഀ Composite Deflectionഀ 1.434 in L / 242.7ഀ 1.650 in L / 210.9ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 10.75 kഀ 11.39 kഀ Compositeഀ 19.62 kഀ 18.07.,kഀ Max DL + LLഀ 30.37 kഀ 29.46 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 92.09 k-ftഀ Fb : Allowഀ 33.00 psi Based on Beam Spanഀ 3.625 ftഀ Dead + Constഀ 92.09 k-ftഀ n : Strengthഀ 8.60 Based on Beam Spacingഀ 6.500 ftഀ Live Load Onlyഀ 166.77 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 257.61 k-ftഀ Effective Widthഀ 3.625 ftഀ Support Shearsഀ Shear @ Leftഀ 30.37 kഀ Shear @ Rightഀ 29.46 kഀ Section Propertiesഀ Section Nameഀ W12X79ഀ Depthഀ 12.380 inഀ Ixx : Steel Sectionഀ 662.00 in4ഀ Widthഀ 12.080 inഀ I transformedഀ 1,471.47 in4ഀ Flange Thickഀ 0.735 inഀ Strains : topഀ 214.01 in3ഀ Web Thickഀ 0.470 inഀ Strans : botഀ 147.08 in3ഀ Areaഀ 23.200 in2ഀ Strans : off @ botഀ 120.74 in3ഀ Weightഀ 78.803 #/ftഀ n'Strans: Ef @ topഀ 1,236.0 in3ഀ ]-steelഀ 662.00 in4ഀ X-X Axis from Botഀ 10.00 inഀ S steel : topഀ 106.95 in3ഀ Vh @ 100%ഀ 222.43 kഀ S steel : bottomഀ 106.95 in3ഀ x$125ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scope :ഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB112ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14ഀ Fy 50.00 ksiഀ Beam Spanഀ 8.000 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 11.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientation Parallelഀ Elastic Modulus 29,000.00 ksiഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.575 k/ftഀ #1 k ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ Point Loads...ഀ #1 0.500 k/ftഀ #1 k ftഀ Summary OK Shored &Unshoredഀ Using: W12X14, Span = 8.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual = 5,193.0 psi Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual = 3,801.3 psi Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual = 1,828.9 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 6,185.3 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 123.8 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 7,027.5 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top * n) 269.8 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 8.75 k V'h : min 15.34 kഀ Total req'd 1/2 Span 2 studs Vh @ 100%0 61.36k Vh : Used 17.50 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.333 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 1.333 ftഀ toഀ 2.667 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 2.667 ftഀ toഀ 4.000 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 4.000 ftഀ toഀ 5.333 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 5.333 ftഀ toഀ 6.667 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 6.667 ftഀ toഀ 8.000 ftഀ , Useഀ 1 studsഀ rQ)gL.ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001 Pageഀ 2ഀ User: KW-0606238, ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ (c)1983-2003 ENERCALC Enoineerina Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB112ഀ Deflectionsഀ I : Transformedഀ 262.87 in4ഀ I : Effective 181.67in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.010 in (after shores removed)ഀ 0.021 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.009 inഀ 0.009 inഀ Total Uncured Deflectionഀ 0.010 in L/9319.8ഀ 0.021 in L / 4545.3ഀ Composite Deflectionഀ 0.019 in L/5039.1ഀ 0.030 in L / 3214.7ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 2.36 kഀ 2.36 kഀ Compositeഀ 2.00 kഀ 2.00 kഀ Max DL + LLഀ 4.36 kഀ 4.36 kഀ Analysis Valuesഀ Maximum Momentsഀ Effective Flange Width...ഀ Dead Load Aloneഀ 4.71 k-ft Fb : Allowഀ 33.00 psiഀ Based on Beam Span 1.000 ftഀ Dead + Constഀ 4.71 k-ft n : Strength.ഀ 8.60ഀ Based on Beam Spacing 5.500 ftഀ Live Load Onlyഀ 4.00 k-ft n : Deflectionഀ 8.51ഀ Dead + Liveഀ 8.71 k-ftഀ Effective Width 1.000 ftഀ Support Shearsഀ Shear @ Leftഀ 4.36 kഀ Shear @ Rightഀ 4.36 kഀ Section Propertiesഀ Section Nameഀ W12X14ഀ Depthഀ 11.910 inഀ Ixx : Steel Sectionഀ 88.60 in4ഀ Widthഀ 3.970 inഀ I transformedഀ 261.96 in4ഀ Flange Thickഀ 0.225 inഀ Strans : topഀ 45.07 in3ഀ Web Thickഀ 0.200 inഀ Strans : botഀ 24.72 in3ഀ Areaഀ 4.160 in2ഀ Strans : eff @ botഀ 20.13 in3ഀ Weightഀ 14.130 #/ftഀ n'Strans : Ef @ topഀ 266.6 in3ഀ I-steelഀ 88.60 in4ഀ X-X Axis from Botഀ 10.60 inഀ S steel : topഀ 14.88 in3ഀ Vh @ 100%ഀ 61.36kഀ S steel :bottomഀ 14.88 in3ഀ Go,i L-7ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ I! 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ •ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580001ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Composite Steel Beam Page 1ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - F131 13ഀ Design Inputഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Nameഀ W8X10ഀ Fy 50.00 ksiഀ Beam Spanഀ 10.500 ftഀ f'c 3,500.00 psiഀ Beam Spacingഀ 8.000 ftഀ Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Stud Diameter 0.750 inഀ Deck Rib Heightഀ 1.500 inഀ Stud Height 3.000 inഀ Rib Spacingഀ 6.000 inഀ Beam Weight Added Internallyഀ Rib Widthഀ 1.750 inഀ Using Partial Composite Actionഀ Rib Orientationഀ Perpendicularഀ Elastic Modulus 29,000.00 ksiഀ Beam Locationഀ Slab One Sideഀ SUnഀ OK Shored & Unshoredഀ Using: W8X10, Span = 10.50ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac=ഀ 6.00in, Rib Width= 1.75in w/ Slab Otഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 20,858.6 psi Allowable =ഀ 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 17,453.7 psi Allowable =ഀ 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 4,776.2 psi Allowable =ഀ 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 27,085.1 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 418.5 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 32,426.7 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans:top ' n) 906.3 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 17.57 kഀ Total req'd 1/2 Span 2studs Vh @ 100% 70.28k Vh : Used 24.79 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 1.680ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 1.680 ftഀ toഀ 3.360 ftഀ , Useഀ 1 studsഀ Zone 3 fromഀ 3.360 ftഀ toഀ 5.040 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 5.040 ftഀ toഀ 6.860 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 6.860 ftഀ toഀ 8.680 ftഀ , Useഀ 1 studsഀ Zone 6 fromഀ 8.680 ftഀ toഀ 10.500 ftഀ , Useഀ 1 studsഀ Monroe & Newell Engineers, Incഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ f-~\2z,ഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Composite Steel Beam Page 2ഀ (0)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Seamsഀ Description Floor Beam - FB113ഀ Deflectionsഀ I : Transformedഀ 128.10 in4ഀ I : Effective 88.58in4ഀ Shoredഀ Unshoredഀ Before 75 % Curingഀ 0.080 in (after shores removed)ഀ 0.231 inഀ Construction Loads Onlyഀ 0.000 inഀ 0.000 inഀ After 75% Curingഀ 0.069 inഀ 0.069 inഀ Total Uncured Deflectionഀ 0.080 in L / 1567.0ഀ 0.231 in L / 544.8ഀ Composite Deflectionഀ 0.149 in L / 843.6ഀ 0.300 in L / 419.7ഀ Reactionsഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ • 3.45ഀ kഀ 3.36 kഀ Compositeഀ 2.95ഀ kഀ 2.88 kഀ Max DL + LLഀ 6.41ഀ kഀ 6.24 kഀ Analysis Valuesഀ Maximum Moments _ഀ Effective Flange Width...ഀ Dead Load Aloneഀ 11.36 k-ftഀ Fb : Allowഀ 33.00 psiഀ Based on Beam Spari 1.312 ftഀ Dead + Constഀ 11.36 k-ftഀ n : Strengthഀ 8.60ഀ Based on Beam Spacing 4.000 ftഀ Live Load Onlyഀ 9.74 k-ftഀ n : Deflectionഀ 8.51ഀ Dead + Liveഀ 21.10 k-ftഀ Effective Width 1.312 ftഀ Support Shearsഀ Shear @ Leftഀ 6.41 kഀ Shear @ Rightഀ 6.24 kഀ Section Propertiesഀ Section Nameഀ W8X10ഀ Depthഀ 7.890 inഀ Ixx : Steel Sectionഀ 30.80 in4ഀ Widthഀ 3.940 inഀ I transformedഀ 127.70 in4ഀ Flange Thickഀ 0.205 inഀ Strans : topഀ 32.48 in3ഀ Web Thickഀ 0.170 inഀ Strans : botഀ 15.10 in3ഀ Areaഀ 2.960 in2ഀ Strans : eff @ botഀ 12.14 in3ഀ Weightഀ 10.054 #/ftഀ n'Strans : Ef @ topഀ 193.2 in3ഀ ]-steelഀ 30.80 in4ഀ X-X Axis from Botഀ 8.46 inഀ S steel : topഀ 7.81 in3ഀ Vh @ 100%ഀ 70.28 kഀ S steel : bottomഀ 7.81 in3ഀ Monroe & Newell Engineers, Inc.ഀ l' 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fav• 3n3.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ n,. 1ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB114ഀ Design Inputഀ Section Name W10X12ഀ 000 ftഀ 4ഀ Beam Spanഀ .ഀ 8.000 ftഀ Beam Spacingഀ Slab Thicknessഀ 4.500 inഀ Deck Rib Heightഀ 1.500 inഀ Rib Spacingഀ 6.000 inഀ Rib Widthഀ 1.750 inഀ Rib Orientation Parallelഀ Beam Location Slab One Sideഀ Dead Loads (applied before 75% curing)ഀ Full Span Uniform Loads...ഀ #1 0.280 k/ftഀ Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads...ഀ #1 0.160 k/ftഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ . -I-ഀ 5500 ecw:8195 Beamsഀ Point Loads...ഀ # 1 2.950 k 3.000 ftഀ ySummary OK Shored & Unshoredഀ 7Striess X12, Span = 4.OOft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ ks for Shored & Unshored Cases. OKഀ Psiഀ om of Beam Actual = 4,550.5 psi Allowable 33,333.0ഀ 3,330.2 Psi Allowable = 33,333.0 psi OKഀ ed DL Stress Actual =ഀ Shear Stress Actual = 3,045.7 psi Allowable = 20,000.0 psi OKഀ Unshored Stress Check.... 45,000.0 psi OK 'ഀ (Mdl/Ss + MII/Strans) Actual = 5,363.9 psi Allowable = Pഀ MII / Strans(top) Actual = 154.2 Psi Allowable = 1,575.0 psi OKഀ 6,021.2 38,000.0 psiഀ Alternate Unshored Stress Check : (Mdl ± MII) / Ss 345.0 1,575.0 psiഀ OL...... rl r`nnnYPtP ~trASs Check (Mdl + Mil) / (Strans:top ' n)ഀ Shear Studs & Shear Transferഀ Actual # Studsഀ Total req'd 1/2 Spanഀ Zone 1 fromഀ Zone 2 fromഀ Zone 3 fromഀ Zone 4 fromഀ Zone 5 fromഀ Zone 6 fromഀ Composite Steel Beamഀ 0 per 1/2 beam span 7.67 kഀ Stud Capacity 8.75 k Vh :minഀ 30.68k V :Used 8.75 kഀ 1 studs Vh @ 100%ഀ 0.000 ftഀ toഀ 0.996 ft , Useഀ 0 studsഀ 0.996 ftഀ toഀ 1.991 ft , Useഀ 1 studsഀ 1.991 ftഀ toഀ 2.987 ft , Useഀ 0 studsഀ 2.987 ftഀ toഀ 3.324 ft , Useഀ 0 studsഀ 3.324 ftഀ toഀ 3.662 ft , Useഀ 0 studsഀ 3.662 ftഀ toഀ 4.000 ft , Useഀ 1 studsഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ m~ഀ Fy 50.00 ksiഀ f'c 3,500.00 psiഀ Concrete Density 145.00 pcfഀ Stud Diameter 0.750 inഀ Stud Height 3.000 inഀ Beam Weight Added Internallyഀ Using Partial Composite Actionഀ Elastic Modulus 29,000.00 ksiഀ Point Loads... 3.000ftഀ # 1 3.460 kഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail`s Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ 623.6602ഀ Fax: 303ഀ .ഀ Page 2ഀ [Rev: seoo01ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Composite Steel Beamഀ 5500.ecw:8195 Beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ ഀ Descriptionഀ Floor Beam - FB114ഀ Deflectionsഀ I : Transformedഀ Iഀ Before 75 % Curingഀ Construction Loads Onlyഀ After 75% Curingഀ Total Uncured Deflectionഀ Composite Deflectionഀ 140.99 in4ഀ Shoredഀ 0.002 inഀ (after shores removed)ഀ 0.000 inഀ 0.002 inഀ 0.002 inഀ L/####,#ഀ 0.004 inഀ L/####.#ഀ I : Effective 100.3Ein4ഀ Unshoredഀ 0.005 inഀ 0.000 inഀ 0.002 inഀ 0.005 in Lഀ 0.007 in L / 7298.5ഀ Reactions r . a.ഀ Load Combinations... @ Left @ Rightഀ Dead + Constuction 1.45 k 3.18 kഀ 1.06 k 2.53 kഀ Compositeഀ Max DL + LL 2.51 k 5.71 kഀ lysis Valuesഀ Maximum Momentsഀ Dead Load Aloneഀ Dead + Constഀ Live Load Onlyഀ Dead + Liveഀ Support Shearsഀ Shear @ Leftഀ Shear @ Rightഀ 3.03 k-ftഀ 3.03 k-ftഀ 2.44 k-ftഀ 5.47 k-ftഀ 2.51 kഀ 5.71 kഀ Effective Flange Width...ഀ Fb : Allow 33.00 psi Based on Beam Spanഀ n : Strength 8.60 Based on Beam Spacingഀ n : Deflection 8.51ഀ Effective Widthഀ 0.500 ftഀ 4.000 ftഀ 0.500 ftഀ Section Propertiesഀ Section Nameഀ W10X12ഀ Depthഀ 9.870 inഀ Ixx :Steel Sectionഀ 53.80 in4ഀ Widthഀ 3.960 inഀ I transformedഀ 140.42 in4ഀ Flange Thickഀ 0.210 inഀ Strans : topഀ 22.13 in3ഀ Web Thickഀ 0.190 inഀ Strans : botഀ 17.50 in3ഀ Areaഀ 3.540 in2ഀ Strans : eff @ botഀ 14.43 in3ഀ Weightഀ 12.024 #/ftഀ n*Strans : Ef @ topഀ 145.3 in3ഀ I-steelഀ 53.80 in4ഀ X-X Axis from Botഀ 8.02 inഀ S steel : topഀ 10.90 in3ഀ Vh @ 100%ഀ 30.68 kഀ S steel : bottomഀ 10.90 in3ഀ ITഀ ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003ഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Descriptionഀ Floor Beam - FB115ഀ Composite Steel Beamഀ Page 1ഀ 55oo.ecw:8195 Beamsഀ Design Input Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Section Name W12X14 Fy 50.00 ksiഀ Beam Span 18.000 ft f'c 3,500.00 psiഀ Beam Spacing 9.000 ft Concrete Density 145.00 pcfഀ Slab Thicknessഀ 4.500 inഀ Deck Rib Heightഀ 1.500 inഀ Rib Spacingഀ 6.000 inഀ Rib Widthഀ 1.750 inഀ Rib Orientationഀ Perpendicularഀ Beam Locationഀ Slab One Sideഀ Stud Diameter 0.750 inഀ Stud Height 3.000 inഀ Beam Weight Added Internallyഀ Using Partial Composite Actionഀ Elastic Modulus 29,000.00 ksiഀ Dead Loads (applied before 75% curing)ഀ Trapezoidal Loads...ഀ # 1 @ Left 0.690 k/ft @ Right 0.690 k/ft 6.500 18.000 ftഀ i Live Loads (applied after 75% curing)ഀ Full Span Uniform Loads... Point Loads...ഀ Trapezoidal Loads...ഀ # 1 @ Leftഀ Summaryഀ 0.600 k/ft @ Right 0.600 k/ftഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ 6.500 18.000 ftഀ OK Shored & Unshoredഀ Using: W1 2X14, Span = 18.00ft, Slab Thickness = 4.500in, Deck Rib Ht= 1.50in, Rib Spac= 6.00in, Rib Width= 1.75in w/ Slab Cഀ Stress Checks for Shored & Unshored Cases...ഀ @ Bottom of Beam Actual =ഀ 21,799.7 psiഀ Allowable = 33,333.0 psi OKഀ Unshored DL Stress Actual =ഀ 17,496.6 psiഀ Allowable = 33,333.0 psi OKഀ Actual Shear Stress Actual =ഀ 4,291.9 psiഀ Allowable = 20,000.0 psi OKഀ Unshored Stress Check....ഀ (Mdl/Ss + MII/Strans) Actual = 27,493.7 psi Allowable = 45,000.0 psi OKഀ MII / Strans(top) Actual = 332.7 psi Allowable = 1,575.0 psi OKഀ Alternate Unshored Stress Check : (Mdl + MII) / Ss 32,316.8 38,000.0 psiഀ Shored Concrete Stress Check (Mdl + MII) / (Strans(top' n) 725.4 1,575.0 psiഀ Shear Studs & Shear Transferഀ Actual # Studs 0 per 1/2 beam spanഀ Stud Capacity 12.40 k V'h : min 26.00 kഀ Total req'd 1/2 Span 3 studs Vh @ 100% 104.00k Vh : Used 37.19 kഀ Zone 1 fromഀ 0.000 ftഀ toഀ 3.400 ftഀ , Useഀ 1 studsഀ Zone 2 fromഀ 3.400 ftഀ toഀ 6.800 ftഀ , Useഀ 2 studsഀ Zone 3 fromഀ 6.800 ftഀ toഀ 10.200 ftഀ , Useഀ 0 studsഀ Zone 4 fromഀ 10.200 ftഀ toഀ 12.800 ftഀ , Useഀ 0 studsഀ Zone 5 fromഀ 12.800 ftഀ toഀ 15.400 ftഀ , Useഀ 2 studsഀ Zone 6 fromഀ 15.400 ftഀ toഀ 18.000 ftഀ , Useഀ 1 studsഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ L 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Page 2ഀ Rev: 580001 Composite Steel Beam 89 5 Ver 5.8.0, 1-Dec-2003 5500.ecw:19ഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB115ഀ Deflectionsഀ I : Transformedഀ Before 75 % Curingഀ Construction Loads Onlyഀ After 75% Curingഀ Total Uncured Deflectionഀ Composite Deflectionഀ 327.90 in4ഀ Shoredഀ 0.179 in (after shores removed)ഀ 0.000 inഀ 0.151 inഀ 0.179 in L/1209.8ഀ 0.330 in L/655-4ഀ I : Effective 231.70n4ഀ Unshoredഀ 0.467 inഀ 0.000 inഀ 0.151 inഀ 0.467 in L / 462.6ഀ 0.618 in L / 349.6ഀ Reactionsഀ Tഀ ഀ Load Combinations...ഀ @ Leftഀ @ Rightഀ Dead + Constuctionഀ 2.66 kഀ 5.53 kഀ Compositeഀ 2.20 kഀ 4.70 kഀ Max DL + LLഀ 4.87 kഀ 10.22 kഀ iഀ Maximum Momentsഀ 69 k-ftഀ 21ഀ Effective Flange Width...ഀ Fb : Allow 33.00 psi Based on Beam Span 2.250 ftഀ Dead Load Aloneഀ .ഀ 6b k-ftഀ 21ഀ n : Strength 8.60 Based on Beam Spacing 4.500 ftഀ Dead + Constഀ .ഀ Live Load Onlyഀ 18.37 k-ftഀ n : Deflection 8'51 Effective Width 2.250 ftഀ Dead + Liveഀ 40.07 k-ftഀ Support Shearsഀ Shear @ Leftഀ 4.87 kഀ Shear @ Rightഀ 10.22 kഀ Section Propertiesഀ Section Nameഀ Depthഀ Widthഀ Flange Thickഀ Web Thickഀ Areaഀ Weightഀ ]-steelഀ S steel : topഀ S steel : bottomഀ W12X14ഀ 11.910 inഀ 3.970 inഀ 0.225 inഀ 0.200 inഀ 4.160 in2ഀ 14.130 #/ftഀ 88.60 in4ഀ 14.88 in3ഀ 14.88 in3ഀ Ixx : Steel Sectionഀ I transformedഀ Strans : topഀ Strans : botഀ Strans : eff @ botഀ n'Strans : Ef @ topഀ X-X Axis from Botഀ Vh @ 100%ഀ 88.60 in4ഀ 327.06 in4ഀ 77.07 in3ഀ 26.88 in3ഀ 22.06 in3ഀ 447.8 in3ഀ 12.17 inഀ 104.00 kഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spaഀ Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PEഀ Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Y'ഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.ഀ 0, 1-Dec-2003 Steel Beam Designഀ Page 1ഀ 5500.ecw:8195 Beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FBI 16 - Non-compഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Mഀ Steel Section : W14X26 Fy 50.00ksiഀ Pinned-Pinned Load Duration Factor 1.00ഀ Center Span 18.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 ft LL & ST Act Togetherഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 6.50 ftഀ Distributed Loadsഀ Note! Short Term Loaas Are wINU Loaas.ഀ ,ഀ # 6 # 7ഀ k/ftഀ k/ftഀ k/ftഀ ftഀ ftഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.469 inഀ Length/DL Defl 847.1: 1ഀ Length/(DL+LL Defl) 460.4: 1ഀ #1ഀ #2 #3ഀ #4 #5ഀ DL 1.035ഀ LL 0.900ഀ STഀ Start Location 6.500ഀ End Location 18.000ഀ Summaryഀ iഀ Using: W 14X26 section, Span =ഀ 18.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 6.50ft, LDF = 1.000ഀ Actualഀ Allowableഀ Momentഀ 60.301 k-ftഀ 80.207 k-ftഀ fb : Bending Stressഀ 20.499 ksiഀ 27.266 ksiഀ fb / Fbഀ 0.752 : 1ഀ Shearഀ 15.379 kഀ 70.941 kഀ fv : Shear Stressഀ 4.336 ksiഀ 20.000 ksiഀ fv/ Fvഀ 0.217 : 1ഀ Force & Stress Summaryഀ <<-- These columns are Dead + Live Load placed as noted »ഀ DLഀ LLഀ LL+STഀ LLഀ LL+STഀ Maximumഀ Onlyഀ @ Centerഀ @ Centerഀ @ Cantsഀ @ Cantsഀ M + 60.30 k-ftഀ Maxഀ 32.74ഀ 60.30ഀ k-ftഀ .ഀ Maxഀ M -ഀ -0.00ഀ -0.00ഀ k-ftഀ .ഀ Max. M @ Leftഀ k-ftഀ k-ftഀ Max. M @ Rightഀ Shear @ Left 7.34 kഀ 4.04ഀ 7.34ഀ kഀ Shear @ Right 15.38 kഀ 8.34ഀ 15.38ഀ kഀ Center Defl. -0.469 inഀ -0.255ഀ -0.469ഀ -0.469ഀ 0.000ഀ 0.000 inഀ Left Cant DO 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 7.34ഀ 4.04ഀ 7.34ഀ 7.34ഀ kഀ Reaction @ Rt 15.38ഀ 8.34ഀ 15.38ഀ 15.38ഀ kഀ Fa calc'd per Eq. E2-2, K'L/r > Ccഀ I Beam, Major Axis, (102,000' Cb / Fy)ഀ 11.5 UrT (51ഀ 0,000' Cb / Fy)^.5ഀ , Fb per Eq. F1-6ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ r Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB116 - Non-compഀ Section Propertiesഀ W14X26ഀ Depthഀ 13.910 inഀ Weightഀ 26.12 #/ftഀ Web Thickഀ 0.255 inഀ Ixxഀ 245.000 in4ഀ Widthഀ 5.025 inഀ lyyഀ 8.910 in4ഀ Flange Thickഀ 0.420 inഀ Sxxഀ 35.300 in3ഀ Areaഀ 7.69 in2ഀ Syyഀ 3.550 in3ഀ Rtഀ 1.280 inഀ R-xxഀ 5.650 inഀ Values for LRFD Design....ഀ R-yyഀ 1.080 inഀ J .ഀ 0.360 in4ഀ Zxഀ 40.200 in3ഀ Cwഀ 405.00 in6ഀ Zyഀ 5.540 in3ഀ Kഀ 0.820 inഀ Page 2ഀ 5500.ecw:8195 Beamsഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580007 Page 1ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Multi-Span Steel Beam 5500.ecw:8195 Beamsഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB117 - Non compഀ Loadsഀ Live Load Used This Span ?ഀ Dead Loadഀ k/ftഀ Live Loadഀ k/ftഀ Point #1 DLഀ kഀ LLഀ kഀ @Xഀ ftഀ Yes Yesഀ 0.690 0.690ഀ 0.600 0.600ഀ 9.390ഀ 8.170ഀ 8.000ഀ Resultsഀ Mmax @ Cntrഀ k-ft lഀ 0.89ഀ 0.00ഀ @ X =ഀ ftഀ 1.20ഀ 8.00ഀ Max @ Left Endഀ k ftഀ 0.00ഀ 181.76ഀ Max @ Right Endഀ k-ftഀ -181.76ഀ 0.00ഀ fb : Actualഀ psi,ഀ 23,085.7ഀ 23,085.7ഀ Fb : Allowableഀ psiഀ 25,888.5ഀ 27,451.0ഀ Bending OKഀ Bending OKഀ fv : Actualഀ psiഀ 2,742.5ഀ 3,522.2ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ kഀ • 1.51ഀ 27.88ഀ Shear @ Rightഀ kഀ 21.71ഀ 17.56ഀ Reactions...ഀ DL @ Leftഀ kഀ , 0.81ഀ 26.52ഀ LL @ Leftഀ kഀ 0.70ഀ 23.07ഀ Total @ Leftഀ kഀ 1.51ഀ 49.59ഀ DL @ Rightഀ kഀ 26.52ഀ 0.00ഀ LL @ Rightഀ kഀ 23.07ഀ 0.00ഀ Total @ Rightഀ kഀ 49.59ഀ 0.00ഀ Max. Deflectionഀ inഀ 0.128ഀ -0.600ഀ @ X =ഀ ftഀ 11.52ഀ 8.00ഀ Span/Deflection Ratioഀ 1,691.1ഀ 320.2ഀ Query valuesഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 00ഀ 0ഀ Shearഀ kഀ 1.51ഀ 00ഀ ' -0ഀ 27.88ഀ -181.76ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ .ഀ 0.00ഀ Momentഀ Max. Deflectionഀ k-ftഀ inഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ 1701 Wynkoop Street, Suite 200 Description : Lodge Expansionഀ Denver, CO 80202ഀ L' 303.623.4927 Scope :ഀ r Fax: 303.623.6602ഀ Rev. 58000' Multi-Span Steel Beamഀ User: KW-0606238, Ver5.8.0,1-Dec•2003ഀ (c) 1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB118 - Non compഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ KICDn rnnnഀ General Informationഀ Fy - Yield Stress 50.00 ksiഀ Spans Considered Continuous Over Supportsഀ pan Informationഀ Code Ref: AISG yin Hou, taar u-,ഀ Descriptionഀ Left Cantഀ Spanഀ Spanഀ ftഀ 2.00ഀ 18.00ഀ Steel Sectionഀ W16X26ഀ W16X26ഀ End Fixityഀ Free-Pinഀ Pin-Pinഀ 00ഀ 9ഀ l Inhraced Lenathഀ ftഀ 2.00ഀ :ഀ k1ഀ kഀ kഀ kഀ kഀ kഀ kഀ kഀ inഀ ftഀ Loadsഀ Live Load Used This Span ? Iഀ Yesഀ Yesഀ Yesഀ Dead Loadഀ k/ftഀ 0.690ഀ 600ഀ 0ഀ 0.690ഀ 600ഀ 0ഀ 0.690ഀ 0.600ഀ Live Loadഀ k/ftഀ .ഀ .ഀ Point #1 DLഀ kഀ 3.290ഀ 1.000ഀ 000ഀ 1ഀ LLഀ kഀ 2.860ഀ .ഀ 000ഀ 1ഀ @ Xഀ ftഀ .ഀ Resultsഀ Mmax @ Cntrഀ k-ftlഀ 0.00ഀ 43.66ഀ 0.00ഀ @ X =ഀ ftഀ 0.00ഀ 9.48ഀ 1.00ഀ Max @ Left Endഀ k-ftഀ 0.00ഀ -14.88ഀ -2.64ഀ 00ഀ 0ഀ Max @ Right Endഀ k-ft'ഀ -14.88ഀ -2.64ഀ .ഀ fb : Actualഀ psiഀ 4,653.7ഀ 13,655.1ഀ 827.2ഀ Fb : Allowableഀ psiഀ 33,000.0ഀ Bending OKഀ 23,029.0ഀ Bending OKഀ 33,000.0ഀ Bending OKഀ fv : Actualഀ psiഀ 2,225.6ഀ 3,133.1ഀ 838.8ഀ Fv : Allowableഀ psiഀ 20,000.0ഀ 20,000.0ഀ 20,000.0ഀ Reactions & Deflectionsഀ Shear @ Leftഀ Shear @ Rightഀ Reactions...ഀ DL @ Leftഀ LL @ Leftഀ Total @ Leftഀ DL @ Rightഀ LL @ Rightഀ Total @ Rightഀ Max. Deflectionഀ @ X=ഀ Span/Deflection Ratioഀ Query Valuesഀ Locationഀ Shearഀ Momentഀ Max. Deflectionഀ 0.00ഀ 8.73ഀ 0.00ഀ 0.00ഀ 0.00ഀ 11.25ഀ 9.77ഀ 21.02ഀ 0.082ഀ 0.00ഀ 582.7ഀ Load Duration Factor 1.00ഀ 12.29ഀ 10.93ഀ 11.25ഀ 9.77ഀ 21.02ഀ 7.53ഀ 6.69ഀ 14.22ഀ -0.279ഀ 9.24ഀ 774.3ഀ Right Cantഀ 1.00ഀ W16X26ഀ Pin-Freeഀ 1.00ഀ 3.29ഀ 2.00ഀ 7.53ഀ 6.69ഀ 14.22ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.050ഀ 1.00ഀ 483.3ഀ ftഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 0.00ഀ k iഀ 0.00ഀ 12.29ഀ 3.29ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ .ഀ 00ഀ 0ഀ .ഀ 0.00ഀ 0.00ഀ k-ftഀ 0.00ഀ -14.88ഀ -2.64ഀ 0.00ഀ 0000ഀ 0ഀ .ഀ 0000ഀ 0ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ iniഀ 0.0824ഀ 0.0000ഀ 0.0000ഀ .ഀ .ഀ Job # 5500.02ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door Spaഀ 1701 W nkoo Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ ഀ y p Street, Suite 200 Description : Lodge Expansionഀ T,ഀ Denver, CO 80202ഀ ' + .1. 303.623.4927 Scopeഀ Fax: 303.623.6602 page 1ഀ Rev 580007 5500.ecw:8195 Beams i, -2003 (c)19 3 2003 ENERCALC En, nDerng Software Multi-Span Steel Beam -ഀ Description Floor Beam - FB119 -Non Compഀ "or, onn3 iRC;. 2003 NFPA 5000ഀ Fy - Yield Stressഀ 50.00 ksiഀ Spans Considered Continuous Over Support:ഀ Span Informatioഀ nഀ Descriptionഀ Cantഀ Spanഀ 4.00ഀ ftഀ Steel Sectionഀ W14X22ഀ Free-Pinഀ End Fixityഀ Unbraced Lengthഀ Iഀ ft 4.00ഀ Loadsഀ Dead Loadഀ Live Loadഀ Resultsഀ Mmax @ Cntrഀ @X=ഀ Max @ Left Endഀ Max @ Right Endഀ fb : Actualഀ Fb : Allowableഀ fv : Actualഀ Fv : Allowableഀ ? Yesഀ k/ft 0.690ഀ k/ft 0.600ഀ Code Het: AISU auiഀ Load Duration Factor 1.00ഀ Spanഀ 11.00ഀ W14X22ഀ Pin-Pinഀ 9.00ഀ Yesഀ 0.690ഀ 0.600ഀ k-ftഀ ftഀ 0.00ഀ 0.00ഀ 14.69ഀ 6.23ഀ k-ftഀ k-ftlഀ 0.00ഀ -10.32ഀ -10.32ഀ 0.00ഀ psi iഀ psi Iഀ psiഀ psiഀ 4,275.3ഀ Be ding OOKഀ 1,632.8ഀ 20,000.0ഀ 6,086.6 21,135.7ഀ Bending OKഀ 2,542.0ഀ 20,000.0ഀ nonr-tinns & Deflectionsഀ Shear @ Leftഀ kഀ 0.00ഀ 8.03ഀ 16ഀ 6ഀ Shear @ Rightഀ kഀ 5.16ഀ .ഀ -Reactions...ഀ kഀ 0 00ഀ 7.06ഀ DL @ Leftഀ kഀ 0.00ഀ 6.14ഀ LL @ Leftഀ kഀ 0.00ഀ 13.19ഀ Total @ Leftഀ DL @ Rightഀ kഀ 7.06ഀ 14ഀ 6ഀ 3.29ഀ 2.86ഀ LL @ Rightഀ kഀ kഀ .ഀ 13.19ഀ 6.16ഀ Total @ Rightഀ Max. Deflectionഀ inഀ 0.027ഀ 00ഀ 0ഀ -0.050ഀ 5.79ഀ @ X =ഀ Span/Deflection Ratioഀ ftഀ .ഀ 3,500.5ഀ 2,614.3ഀ Query Valuesഀ 00ഀ 0ഀ c.ocഀ 0.00ഀ 0.00ഀ Locationഀ ftഀ 0.00ഀ 0.00ഀ 03ഀ 8ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ .ഀ 0.00ഀ 0.00ഀ 00ഀ 0ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0.00ഀ Shearഀ ft1ഀ 0.00ഀ 00ഀ 0ഀ .ഀ 10.32ഀ 0.00ഀ 0.00ഀ 0.00ഀ 0000ഀ 0ഀ .ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ Momentഀ k-ഀ iഀ .ഀ 0 0274ഀ 0.0000ഀ 0.0000ഀ 0.0000ഀ .ഀ Max. Deflectionഀ nഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Description :Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Y Fax: 303.623.6602ഀ [Lu.evr: 580006 Page 1ഀ KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Bear Design 5500.ecw:8195 Beamsഀ 83.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB120 - Non compഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Fy 50 00 ks!ഀ Steel Section : W18X35 Pinned-Pinned Load Duration Factor 1.00ഀ Center Span 18.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 ft LL & ST Act Togetherഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 9.00 ftഀ Distributed Loadsഀ ~T # 1ഀ DL 0.465ഀ LL 1.550ഀ STഀ Start Locationഀ End Locationഀ Note! Snort ! erril LUdUJ .,iG vv nvv wauo.ഀ #2 #3ഀ Point Loadsഀ #1ഀ #2 #ഀ Dead Load 4.040ഀ Live Load 3.300ഀ Short Termഀ Location 9.000ഀ Summaryഀ Using: W1 8X35 section, Span =ഀ 18.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Luഀ = 9.00ft, LDF = 1.000ഀ Actualഀ Momentഀ 116.054 k-ftഀ fb : Bending Stressഀ 24.178 ksiഀ fb / Fbഀ 0.977 : 1ഀ Shearഀ 22.120 kഀ fv : Shear Stressഀ 4.166 ksiഀ fv / Fvഀ 0.208 : 1ഀ ueam ur,ഀ Static Load Case Governs Stressഀ Allowableഀ 118.794 k-ftഀ Max. Deflection -0.432 inഀ 24.749 ksiഀ Length/DL DO 1,574.4 :1ഀ Length/(DL+LL Defl) 500.5 : 1ഀ 106.200 kഀ 20.000 ksiഀ Force & Stress Summഀ -ഀ #4ഀ #5ഀ #6ഀ #7ഀ k/ftഀ k/ftഀ k/ftഀ ftഀ ftഀ Note! JnOrt I erin LUdUS hiC vvnvv wauo.ഀ #6 #7ഀ kഀ kഀ kഀ ftഀ DLഀ Maximum Onlyഀ <<-- These columns are Dead + Live Load p!aceo as noteo »ഀ LL LL+ST . LL LL+STഀ @ Center @ Center @ Cants @ Cantsഀ 16 05 k-ftഀ Max. M+ഀ 116.05 k-ftഀ 38.43ഀ 1ഀ k ftഀ Max. M -ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ Shear @ Leftഀ 22.12 kഀ 6.52ഀ 22.12ഀ kഀ kഀ Shear @ Rightഀ 22.12 kഀ 6.52ഀ 22.12ഀ Center Defl.ഀ -0.432 inഀ -0.137ഀ -0.432ഀ -0.432ഀ 000ഀ 0ഀ 0.000ഀ 000ഀ 0ഀ 0.000 inഀ 0.000 inഀ Left Cant DOഀ 0.000 inഀ iഀ 0.000ഀ 000ഀ 0ഀ 0.000ഀ 000ഀ 0ഀ .ഀ 0.000ഀ .ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ nഀ 0.000ഀ .ഀ .ഀ ...Query Defl @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Leftഀ 22.12ഀ 6.52ഀ 22.12ഀ 22.12ഀ kഀ kഀ Reaction @ Rtഀ 22.12ഀ 6.52ഀ 22.12ഀ 22.12ഀ Fa calc'd per Eq. E2-2, K*Ur > Ccഀ I Beam, Major Axis, (ഀ 102,000 * Cb / Fy)A.5 UrT (510ഀ ,000 * Cb / Fy)A•5ഀ , Fb per Eq. F1-6ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Page 2ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design 55oo.ecw:8195 Beamsഀ (c)1983-2003 ENERCALC Engineering Software - - -ഀ Description Floor Beam - FB120 -Non compഀ Section Propertiesഀ W1 8X35ഀ Depthഀ 17.700 inഀ Web Thickഀ 0.300 inഀ Widthഀ 6.000 inഀ Flange Thickഀ 0.425 inഀ Areaഀ 10.30 in2ഀ Rtഀ 1.490 inഀ Values for LRFD Design....ഀ Jഀ 0.510 in4ഀ CWഀ 1,140.00 in6ഀ Weightഀ 34.99 #/ftഀ Ixxഀ 510.000 in4ഀ lyyഀ 15.300 in4ഀ Sxxഀ 57.600 in3ഀ Syyഀ 5.120 in3ഀ R-xxഀ 7.040 inഀ R-yyഀ 1.220 inഀ Zxഀ 66.500 in3ഀ Zyഀ 8.060 in3ഀ Kഀ 0.827 inഀ Monroe & Newell Engineers, Inc.ഀ Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200ഀ Dsgnr: Arthur Ashworth, PE Date: 3:54PM, 13 DEC 05ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ Rev: 580006 Steel Beaഀ User: KW-0606238, Ver 5.8.0, 1 -Dec-2003ഀ m Design Page 1ഀ 5500.ecw:8195 Beamsഀ (c)1983.2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB121 -Non compഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ General Informationഀ Sze=ഀ Fy 50.00ksiഀ Steel Section : W16X26ഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Span 18.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksiഀ Left Cant. 0.00 ft LL & ST Act Togetherഀ Right Cant 0.00 ftഀ Lu : Unbraced Length 9.00 ftഀ Note! Short Term Loads Are WIND Loads.ഀ Distributed Loadsഀ #1 #2 #3ഀ #4 #5 #6 #7 k/ftഀ DL 0.020ഀ k/ftഀ LL 0.020ഀ k/ftഀ STഀ ftഀ Start Locationഀ ftഀ End Locationഀ Note! Short Term Loads Are WIND Loads..ഀ Point Loadsഀ #1 #2 #3ഀ #4 #5 #6 #7 kഀ Dead Load 6.640 4.040ഀ kഀ Live Load 19.000 3.300ഀ kഀ Short Termഀ ftഀ Location 2.500 9.000ഀ Summaryഀ Load Caseഀ Stഀ tiഀ Beam OKഀ Governs Stressഀ xഀ Using: W 16X26 section, Span = 18.00ft, Fy = 50.Oksiഀ cഀ aഀ End Fixity = Pinned-Pinned, Lu = 9.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 67.756 k-ftഀ 73.693 k-ftഀ Max. Deflectionഀ -0.448 inഀ fb : Bending Stress 21.174 ksiഀ 23.029 ksiഀ Length/DL Deflഀ 1,234.8: 1ഀ fb / Fb 0.919 : 1ഀ Length/(DL+LL Defl)ഀ 482.5: 1ഀ Shear 26.344 kഀ 78.450 kഀ fv : Shear Stress 6.716 ksiഀ 20.000 ksiഀ fv / Fv 0.336 : 1ഀ Force & Stress Suഀ These columns are Dead + Live Load placed as noted »ഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ k-ftഀ Max. M + 67.76 k-ftഀ 28.35ഀ 67.76 .ഀ k-ftഀ Max. M -ഀ k -ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ Shear @ Left 26.34 kഀ 8.15ഀ 26.34ഀ kഀ kഀ Shear @ Right 7.83 kഀ 3.36ഀ 7.83ഀ Center Defl. -0.448 inഀ -0.175ഀ -0.448ഀ -0.448ഀ 0.000ഀ 000ഀ 0ഀ 0.000 inഀ 000 inഀ 0ഀ Left Cant Defl 0.000inഀ iഀ 0.000ഀ 000ഀ 0ഀ 0.000ഀ 0ഀ 000ഀ 0.000ഀ 0.000ഀ .ഀ 0.000ഀ .ഀ 0.000 inഀ nഀ Right Cant Defl 0.000ഀ .ഀ .ഀ ...Query DO @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 26.34ഀ 8.15ഀ 26.34ഀ 26.34ഀ kഀ kഀ Reaction @ Rt 7.83ഀ 3.36ഀ 7.83ഀ 7.83ഀ Fa calc'd per Eq. E2.2, K'L/r > Ccഀ I Beam, Major Axis, (102,000' Cb / Fy)^.5 L/rT (510ഀ ,000' Cb / Fy)^.5ഀ , Fb per Eq. F1-6ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Job # 5500.02ഀ Date: 3:54PM, 13 DEC 05ഀ 303.623.4927ഀ Scope :ഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1963.2003 ENERCALC Engineering Softwareഀ Page 2ഀ 5500.ecw:8195 Beamsഀ Descriptionഀ Floor Beam - FB121 -Non compഀ Section Propertiesഀ W16X26ഀ Depthഀ 15.690 inഀ Weightഀ 26.09 #/ftഀ Web Thickഀ 0.250 inഀ Ixxഀ 301.000 in4ഀ Widthഀ 5.500 inഀ lyyഀ 9.590 in4ഀ Flange Thickഀ 0.345 inഀ Sxxഀ 38.400 in3ഀ Areaഀ 7.68 in2ഀ Syyഀ 3.490 in3ഀ Rtഀ 1.360 inഀ R-xxഀ 6.260 inഀ R-yyഀ 1.120 inഀ Values for LRFD Design....ഀ Jഀ 0.260 in4ഀ Zxഀ 44.200 in3ഀ Cwഀ 565.00 in6ഀ Zyഀ 5.480 in3ഀ Kഀ 0.747 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ Dsgnr: Arthur Ashworth, PE Date: 7:05AM, 14 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Page 1ഀ Re": 56°°06ഀ Steel Beam Designഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 5500.ecw:6195 Beamsഀ (c)1983-2003 ENERCALC Engineering Software _ഀ Description Floor Beam - FB122 - Non Compഀ General Informationഀ Steel Section : W18X50ഀ Center Spanഀ Left Cant.ഀ Right Cantഀ Lu : Unbraced Lengthഀ Point Loadsഀ Code Ref: AISC 9th ASU, 199/ Utbu, zUUO rnu, eu- -r-ഀ #1 #2 #3 #4ഀ Dead Load 4.040. 2.280 4.730 3.190ഀ Live Load 3.300 6.460 5.800 10.630ഀ Short Termഀ Location 7.500 8.500 13.500 17.500ഀ Using: W1 8X50 section, Span = 23.00ft, Fy = 50.Oksiഀ End Fixity Pinned-Pinned, Lu = 9.00ft, LDF = 1.000ഀ Actualഀ Allowableഀ Moment 159.824 k-ftഀ 209.429 k-ftഀ fb : Bending Stress 21.574 ksiഀ 28.269 ksiഀ fb / Fb 0.763 : 1ഀ Shear 22.894 kഀ 127.729 kഀ fv : Shear Stress 3.585 ksiഀ 20.000 ksiഀ fv / Fv 0.179 : 1ഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.643 inഀ Length/DL Defl 1,140.4: 1ഀ Length/(DL+LL Defl) 429.3: 1ഀ Force & Stressഀ Maximumഀ Max. M +ഀ 159.82 k-ftഀ Max. M -ഀ Max. M @ Leftഀ Max. M @ Rightഀ Shear @ Leftഀ 18.68 kഀ Shear @ Rightഀ 22.89 kഀ Center Defl.ഀ -0.643 inഀ Left Cant DOഀ O.000inഀ Right Cant Deflഀ 0.000 inഀ ...Query Defl @ഀ 0.000 ftഀ Reaction @ Leftഀ 18.68ഀ Reaction @ Fitഀ 22.89ഀ Fa calc'd per Eq. E2ഀ -2, K*L/r > Ccഀ I Beam, Major Axis, (102,000 * Cb / F~ഀ Section Propertiesഀ W1 8X50ഀ Depthഀ 17.990 inഀ Web Thickഀ 0.355 inഀ Widthഀ 7.495 inഀ Flange Thickഀ 0.570 inഀ Areaഀ 14.70 in2ഀ Rtഀ 1.940 inഀ Values for LRFD Design..ഀ ഀ Jഀ 1.240 in4ഀ Cwഀ 3,040.00 in6ഀ DLഀ Onlyഀ 60.36ഀ Pinned-Pinnedഀ 23.00 ft Bm Wt. Added to Loadsഀ 0.00 ft LL & ST Act Togetherഀ 0.00 ftഀ 9.00 ftഀ 7.45ഀ 7.94ഀ -0.242ഀ 0.000ഀ 0.000ഀ 0.000ഀ 7.45ഀ 7.94ഀ <<-- Theseഀ columns are Dead + Live Load placed as noted »ഀ LLഀ LL+STഀ LLഀ LL+STഀ @ Centerഀ @ Centerഀ @ Cantsഀ @ Cantsഀ 159.82ഀ k-ftഀ k-ftഀ k-ftഀ k-ftഀ 18.68ഀ kഀ 22.89ഀ kഀ -0.643ഀ -0.643ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ 18.68ഀ 18.68ഀ kഀ 22.89ഀ 22.89ഀ kഀ .5 L/rT (510,000 * Cb / FV)^.5 , Fb per Eq. F1-6ഀ Weightഀ 49.93 #/ftഀ Ixxഀ 800.000 in4ഀ lyyഀ 40.100 in4ഀ Sxxഀ 88.900 in3ഀ gyyഀ 10.700 in3ഀ R-xxഀ 7.380 inഀ R-yyഀ 1.650 inഀ Zxഀ 101.000 in3ഀ Zyഀ 16.600 in3ഀ Kഀ 0.972 inഀ Load Duration Factor 1.00ഀ Elastic Modulus 29,000.0 ksiഀ Note! Short Term Loads Are WIND Loads.ഀ #5 #6 #7ഀ kഀ kഀ kഀ ftഀ Job # 5500.02ഀ Monroe & Newell Engineers, Inc. Title : rt Front Door Spaഀ Dsgnr: Arthur Ashworth, PE Date: 7:05AM, 14 DEC 05ഀ 1701 Wynkoop Street, Suite 200ഀ Description : Lodgeഀ Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scope :ഀ Fax: 303.623.6602ഀ Page 1 rഀ Rev: 580006ഀ eel Beam Designഀ 003ഀ 5500 .ecw8195 Beamsഀ User: KW0606238, Ver 5.8.0, 1-Dec-2ഀ ഀ c)183.2003 ENERCALC Engineering Software =ഀ 4ഀ .ഀ onഀ Description Floor Beam - F6123 - mpഀ Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ General Informationഀ _ഀ ooksiഀ 5oഀ Fyഀ .ഀ Steel Section : W16X26 Pinned-Pinned Load Duration Factor 1.00ഀ Oksiഀ 000ഀ 29ഀ Elaഀ 00 ft Bm Wt. Added to Loadsഀ 18ഀ .ഀ ,ഀ stic Modulusഀ .ഀ Center Spanഀ 00 ft LL & ST Act Togetherഀ 0ഀ .ഀ Left Cant.ഀ 00 ftഀ 0ഀ .ഀ Right Cantഀ Lu : Unbraced Length 6.50 ftഀ Note! Short Term Loads Are WIND Loads.ഀ Distributed Loadsഀ #1 #2 #3 #4 #5ഀ # 7ഀ #6 k/ftഀ DL 1.035ഀ k/ftഀ LL 0.900ഀ k/ftഀ STഀ ftഀ Start Location 6.500ഀ ftഀ End Location 18.000ഀ Note! Short Term Loads Are WIND Loads.ഀ Point Loadsഀ _ഀ #5ഀ # 7ഀ #6ഀ a:.ഀ .ഀ #1 #2 #3 #4ഀ kഀ Dead Load 1.950ഀ kഀ Live Load 5.850ഀ kഀ Short Termഀ ftഀ Location 6.500ഀ Summaryഀ Beam OKഀ Static Load Case Governs Stressഀ f Using W 16X26 section, Span= 18.00ft, Fy = 50.Oksiഀ End Fixity - Pinned Pinned, Lu = 6.50ft, LDF = 1.000ഀ Allowableഀ Actualഀ 410 k-ft 89.467 k-ftഀ 84ഀ Max. Deflection -0.549 inഀ .ഀ Momentഀ fb :Bending Stress 26.378 ksi 27,959 ksiഀ Length/DL Defl 866.8 :1ഀ fb / Fb 0.943 : 1ഀ Length/(DL+LL Defl) 393.5 :1ഀ Shear 18.196 k 78.450 kഀ 639 ksi 20.000 ksiഀ 4ഀ .ഀ fv : Shear Stressഀ fv / Fv 0.232: 1ഀ Force & Stress Summaryഀ These columns are Deadഀ + Live Load placed a notedഀ »ഀ DL LL LL+STഀ m Only @ Center @ Centerഀ iഀ STഀ @ Cants @ Cantsഀ muഀ Maxഀ M + 84.41 k-ft 38.50 84.41ഀ Maxഀ k ftഀ k-ftഀ .ഀ Max. M - -0.00 -0.00ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ kഀ Shear @ Left 12.33 k 5.28 12.33ഀ 20ഀ 18ഀ kഀ .ഀ Shear @ Right 18.20 k 9.04ഀ 0.549 in -0.249 -0.549 -0.549ഀ Center Defl.ഀ 000 0.000ഀ 0ഀ 0.000 0.000 inഀ 0.000 0.000 inഀ Dഀ .ഀ O.O in 0.000 0ഀ Left Cant ntഀ .000 0.000ഀ 000ഀ 0ഀ iഀ 0.000 0.000 inഀ Dഀ .ഀ nഀ Right Cant t Defl 0.000 0ഀ 000 0.000 0.000ഀ 0ഀ 0.000 0.000 inഀ .ഀ ...Query DO @ 0.000 ftഀ Reaction @ Left 12.33 5.28 12.33 12.33 18ഀ 20 18.20ഀ kഀ kഀ .ഀ Reaction @ Rt 18.20 9.04ഀ Fa calc'd per Eq. E2-2, K'L/r > Ccഀ 5 L/rT (510,000' Cb / FV)".5 , Fb per Eq. F1-6ഀ ഀ 0' Cb / Fഀ Vഀ .ഀ I Beam, Maior Axis, (102,00ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Denver, CO 80202 Description : Lodge Expansionഀ " 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Job # 5500.02ഀ Date: 7:05AM, 14 DEC 05ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB123 - Non-compഀ Page 2ഀ 5500.ecw:8195 Beamsഀ Section Propertiesഀ W1 6X26ഀ Depthഀ 15.690 inഀ Weightഀ 26.09 #/ftഀ Web Thickഀ 0.250 inഀ Ixxഀ 301.000 in4ഀ Widthഀ 5.500 inഀ lyyഀ 9.590 in4ഀ Flange Thickഀ 0.345 inഀ Sxxഀ 38.400 in3ഀ Areaഀ 7.68 in2ഀ Syyഀ 3.490 in3ഀ Rtഀ 1.360 inഀ R-xxഀ 6.260 inഀ Values for LRFD Design....ഀ R-yyഀ 1.120 inഀ Jഀ 0.260 in4ഀ Zxഀ 44.200 in3ഀ CWഀ 565.00 in6ഀ Zyഀ 5.480 in3ഀ Kഀ 0.747 inഀ J "iaഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 7:05AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ •ഀ 303.623.4927 Scope:ഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 1ഀ (c) 1983-2003 ENE RCALC Engineering Software 5500.ecw:8195 Beamsഀ "w"ഀ Description Floor Beam - FB124 - Non-compഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W16X36ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 18.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 6.50 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ DL 1.035ഀ k/ftഀ LL 0.900ഀ k/ftഀ STഀ k/ftഀ Start Location 6.500ഀ ftഀ End Location 18.000ഀ ftഀ Point Loads Note! Short Term Loads Are WIND Loads.ഀ #1 #2 #3 #4 #5 #6 #7ഀ Dead Load 2.630 1.560 kഀ Live Load 8.100 5.210 kഀ Short Term kഀ Location 6.500 6.500 ftഀ zummaryഀ Using: W16X36 section, Spanഀ = 18.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lഀ u = 6.50ft, LDF = 1.000ഀ Actualഀ Momentഀ 120.418 k-ftഀ fb : Bending Stressഀ 25.576 ksiഀ fb / Fbഀ 0.853 : 1ഀ Shearഀ 21.788 kഀ fv : Shear Stressഀ 4.657 ksiഀ fv / Fvഀ 0.233 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+ST LLഀ LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cantsഀ @ Cantsഀ Max. M +ഀ 120.42 k-ftഀ 46.10ഀ 120.42ഀ k-ftഀ Max. M -ഀ -0.00ഀ -0.00ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Leftഀ 18.61 kഀ 6.80ഀ 18.61ഀ kഀ Shear @ Rightഀ 21.79 kഀ 9.94ഀ 21.79ഀ kഀ Beam OKഀ Static Load Case Governs Stressഀ Allowableഀ 141.250 k-ftഀ Max. Deflection -0.511 inഀ 30.000 ksiഀ Length/DL Defl 1,071.8 : 1ഀ Length/(DL+LL Defl) 422.6 :1ഀ 93.574 kഀ 20.000 ksiഀ Center Defl. -0.511 inഀ -0.202ഀ -0.511ഀ -0.511ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 18.61ഀ 6.80ഀ 18.61ഀ 18.61ഀ kഀ Reaction @ Rt 21.79ഀ 9.94ഀ 21.79ഀ 21.79ഀ kഀ Fa calc'd per Eq, E2-1, K`Ur < Ccഀ I Beam, Major Axis, UrT < (102,000 ` Cbഀ / Fy)A.5, Fb = 0.6ഀ Fy (F3)ഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 7:05AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ Fax: 303.623.6602ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 2ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB124 - Non-compഀ Section Propertiesഀ W1 6X36ഀ Depthഀ 15.860 inഀ Weightഀ 36.00 #/ftഀ Web Thickഀ 0.295 inഀ Ixxഀ 448.000 in4ഀ Widthഀ 6.985 inഀ lyyഀ 24.500 in4ഀ Flange Thickഀ 0.430 inഀ Sxxഀ 56.500 in3ഀ Areaഀ 10.60 in2ഀ Syyഀ 7.000 in3ഀ Rtഀ 1.790 inഀ R-xxഀ 6.510 inഀ Values for LRFD Design....ഀ R-yyഀ 1.520 inഀ Jഀ 0.540 in4ഀ Zxഀ 64.000 in3ഀ Cwഀ 1,460.00 in6ഀ Zyഀ 10.800 in3ഀ Kഀ 0.832 inഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spaഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Denver, CO 80202ഀ 303.623.4927 Scopeഀ Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB125 - Non-compഀ Job # 5500.02ഀ Date: 7:05AM, 14 DEC 05ഀ Page 1ഀ 5500.ecw:8195 Beamsഀ I General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W16X26ഀ Fy 50.00ksiഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 18.00 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.0 ksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 6.50 ftഀ DiStrlbuted LOadSഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 T #4ഀ #5 #6 #7ഀ .DL 1.035ഀ k/ftഀ LL 0.900ഀ k/ftഀ STഀ k/ftഀ Start Location 6.500ഀ ftഀ End Location 18.000ഀ ftഀ Point Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ Dead Load 1.170ഀ -0.110ഀ -0.020 0.040ഀ kഀ Live Load 3.890ഀ -0.370ഀ -0.050 0.440ഀ kഀ Short Term kഀ Location 6.500 6.500 6.500 6.500 ftഀ Summaryഀ Using: W 16X26 section, Span = 18.00ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 6.50ft, LDF = 1.000ഀ Actual Allowableഀ Moment 75.258 k-ft 89.467 k-ftഀ fb : Bending Stress 23.518 ksi 27.959 ksiഀ fb / Fb 0.841 : 1ഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.489 inഀ Length/DL Defl 936.8 : 1ഀ Length/(DL+LL Defl) 442.1 :1ഀ Shear 17.181 k 78.450 kഀ fv : Shear Stress 4.380 ksi 20.000 ksiഀ fv / Fv 0.219 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as noted »ഀ DLഀ LL LL+ST LLഀ LL+STഀ Maximumഀ Onlyഀ @ Center @ Center @ Cantsഀ @ Cantsഀ Max. M + 75.26 k-ftഀ 35.87ഀ 75.26ഀ k-ftഀ Max. M -ഀ -0.00ഀ -0.00ഀ k-ftഀ Max. M @ Leftഀ k-ftഀ Max. M @ Rightഀ k-ftഀ Shear @ Left 10.53 kഀ 4.73ഀ 10.53ഀ kഀ Shear @ Right 17.18 kഀ 8.73ഀ 17.18ഀ kഀ Center Defl. -0.489 inഀ -0.231ഀ -0.489ഀ -0.489ഀ 0.000ഀ 0.000 inഀ Left Cant Defl 0.000inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Defl 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Left 10.53ഀ 4.73ഀ 10.53ഀ 10.53ഀ kഀ Reaction @ Rt 17.18ഀ 8.73ഀ 17.18ഀ 17.18ഀ kഀ Fa calc'd per Eq. E2-2, K'L/r > Ccഀ I Beam, Major Axis, (102,000' Cb / FV)A.ഀ 5 L/rT (510,ഀ 000' Cb / FV)A.5ഀ , Fb per Eq. F1-6ഀ Vഀ Monroe & Newell Engineers, Inc. Title : Vail's Front Door - Spa Job # 5500.02ഀ 1701 Wynkoop Street, Suite 200 Dsgnr: Arthur Ashworth, PE Date: 7:05AM, 14 DEC 05ഀ Denver, CO 80202 Description : Lodge Expansionഀ 303.623.4927ഀ Scopeഀ y ; Fax: 303.623.6602ഀ Rev: 580006ഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 2ഀ (c)1983-2003 ENERCALC Engineering Software 5500.ecw:8195 Beamsഀ Description Floor Beam - FB125 - Non-compഀ Section Propertiesഀ W1 6X26ഀ Depthഀ 15.690 inഀ Weightഀ 26.09 #/ftഀ Web Thickഀ 0.250 inഀ Ixxഀ 301.000 in4ഀ Widthഀ 5.500 inഀ lyyഀ 9.590 in4ഀ Flange Thickഀ 0.345 inഀ Sxxഀ 38.400 in3ഀ Areaഀ 7.68 in2ഀ Syyഀ 3.490 in3ഀ Rtഀ 1.360 inഀ R-xxഀ 6.260 inഀ Values for LRFD Design....ഀ R-yyഀ 1.120 inഀ Jഀ 0.260 in4ഀ Zxഀ 44.200 in3ഀ Cwഀ 565.00 in6ഀ Zyഀ 5.480 in3ഀ Kഀ 0.747 inഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 10:04AM, 14 DEC 05ഀ n v. oovvvoഀ User: KW-0606238, Very-8.0, 1-Dec-2003 Steel Beam Designഀ (c)1983-2003 ENERCALC Enoineerina Softwareഀ Description Floor Beam - FB130 - Non compഀ Page 1ഀ 5500.ecw:8195 Beamsഀ General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000ഀ Steel Section : W12X14ഀ Pinned-Pinnedഀ Load Duration Factor 1.00ഀ Center Spanഀ 7.50 ftഀ Bm Wt. Added to Loadsഀ Elastic Modulus 29,000.Oksiഀ Left Cant.ഀ 0.00 ftഀ LL & ST Act Togetherഀ Right Cantഀ 0.00 ftഀ Lu : Unbraced Lengthഀ 7.50 ftഀ Distributed Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ #3 #4ഀ #5 #6 #7ഀ DLഀ 0.020ഀ k/ftഀ LLഀ 0.020ഀ k/ftഀ STഀ k/ftഀ Start Locationഀ ftഀ End Locationഀ 7.500ഀ ftഀ Point Loadsഀ Note! Short Term Loads Are WIND Loads.ഀ #1ഀ #2ഀ S73 #4ഀ #5 #6 #7ഀ Dead Loadഀ 2.500ഀ kഀ Live Loadഀ 8.320ഀ kഀ Short Termഀ kഀ Locationഀ 5.000ഀ ftഀ Summaryഀ Using: W 12X14 section, Span = 7.50ft, Fy = 50.Oksiഀ End Fixity = Pinned-Pinned, Lu = 7.50ft, LDF = 1.000ഀ Actual Allowableഀ Moment 18.301 k-ft 23.180 k-ftഀ fb : Bending Stress 14.739 ksi 18.668 ksiഀ fb / Fb 0.790 : 1ഀ Shear 7.416 k 47.640 kഀ fv : Shear Stress 3.113 ksi 20.000 ksiഀ fv / Fv 0.156 : 1ഀ Beam OKഀ Static Load Case Governs Stressഀ Max. Deflection -0.056 inഀ Length/DL Defl 6,594.4 :1ഀ Length/(DL+LL Defl) 1,593.0 : 1ഀ Force & Stress Summaryഀ These columns are Dead + Live Load placed as notedഀ DL LL LL+ST LL LL+STഀ Maximum Only @ Center @ Center @ Cants @ Cantsഀ Max. M + 18.30 k-ft 4.36 18.30 k-ftഀ Max. M - k-ftഀ Max. M @ Left k-ftഀ Max. M @ Right k-ftഀ Shear @ Leftഀ 3.81 kഀ 0.96ഀ 3.81ഀ kഀ Shear @ Rightഀ 7.42 kഀ 1.79ഀ 7.42ഀ kഀ Center Defl.ഀ -0.056 inഀ -0.014ഀ -0.056ഀ -0.056ഀ 0.000ഀ 0.000 inഀ Left Cant Deftഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Right Cant Deflഀ 0.000 inഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ ...Query Defl @ഀ 0.000 ftഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000ഀ 0.000 inഀ Reaction @ Leftഀ 3.81ഀ 0.96ഀ 3.81ഀ 3.81ഀ kഀ Reaction @ Rtഀ 7.42ഀ 1.79ഀ 7.42ഀ 7.42ഀ kഀ Fa calc'd per Eq. E2-2, K*L/r > Ccഀ I Beam, Major Axis, (ഀ 102,000 * Cb / Fy)A.ഀ 5 UrT (510,ഀ 000 * Cb / Fv)^.5ഀ , Fb per Eq. F1-6ഀ Monroe & Newell Engineers, Inc.ഀ 1701 Wynkoop Street, Suite 200ഀ Denver, CO 80202ഀ 303.623.4927ഀ Fax: 303.623.6602ഀ Title : Vail's Front Door - Spaഀ Dsgnr: Arthur Ashworth, PEഀ Description : Lodge Expansionഀ Scope :ഀ Job # 5500.02ഀ Date: 10:04AM. 14 DEC 05ഀ nev. Jovvvoഀ User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Designഀ (0)1983-2003 ENERCALC Engineering Softwareഀ Description Floor Beam - FB130 -lNon compഀ Section Propertiesഀ W12X14ഀ ,ഀ Depthഀ 11.910 inഀ Weightഀ 14.13 #/ftഀ Web Thickഀ 0.200 inഀ Ixxഀ 88.600 in4ഀ Widthഀ 3.970 inഀ lyyഀ 2.360 in4ഀ Flange Thickഀ 0.225 inഀ Sxxഀ 14.900 in3ഀ Areaഀ 4.16 in2ഀ Syyഀ 1.190 in3ഀ Rtഀ 0.950 inഀ R-xxഀ 4.620 inഀ Values for LRFD Design....ഀ R-yyഀ 0.753 inഀ 1ഀ 0.070 in4 'ഀ Zxഀ 17.400 in3ഀ Cwഀ 80.60 in6ഀ Zyഀ 1.900 in3ഀ Kഀ 0.525 inഀ Page 2ഀ 5500.ecw:8195 Beamsഀ Column Designഀ 4 . vp,'f 10 ERIE-()ഀ 14.8 rA <Xoഀ x jctl I OPEN Q C Cഀ Z A&ഀ a H55 6 N UPഀ 1'16',1 `s0 - X61 ~ %olഀ ~ഀ RED`ഀ f TORഀ LE ti f _ SI, p~ O pQഀ 1n18Y-106 w1OXk2 ~4j 1NGഀ Op E Gഀ G pL MN Up 1,4ഀ /f OPEN X Ioy12 J4,ഀ .X @1'ffi= 1 ~ഀ ' :ter: 8 : • ' ' 3 10~ -ഀ ~XI 1/2°{4 X 182',10..ഀ OF RETEഀ IRS - ~ --~f-' TOp ~ GONGഀ :~:X gRA ~Xy/4 TRIG p1_{ t•F2''.ഀ 5X3X1/4 r 4X~ - T5 3 ER r`~ SL gip.ഀ NG 22 y1TEഀ 12X14 [IOj 4 c ME1''IfAO OEG INSഀ )MN UP j18i~~~st :tF ~ : VAഀ VA -*A VT-ഀ X~. : ,n112 X14 tkO7 C H2S 6X6XP4ഀ X ::::::{i.U3':.". : • ::.:.:';'2:: • COLUMN 11ഀ ~ ~ • 4 . Ham? _ Uഀ -42ഀ i 4ഀ VAIഀ 5X3X1/4 i 1/4.... O EXIcJT1N I1, 1ഀ IMN UP i 5:X X p ILഀ 22 _ -,4X ` - 1 w12XI4 10ഀ - X12 5~ - Tഀ - J4ഀ 4 1 011: ~ (Q1) T 1 H55 UMN VPഀ ~ഀ ~ ~5 (818► GDI-ഀ CAST IN 12 [5~ 6X6X'ഀ PLACE i 1 Ut'IN Up Iഀ CONCRETE 1 VAI, Xഀ STAIRS i G fഀ j4 I t5~ I I w,~X,4 U01 Gഀ ! _ ~r r Oxഀ t2 [5l w2112 6 'ഀ OLഀ - i -ഀ C4 IOX12 X4 L~ഀ ylഀ C3ഀ ~ xഀ aഀ VA% X12 i, _ _ V I X,4ഀ x ' = Up / - -ഀ 9ഀ 77ഀ : P = G NGR Mഀ FOP'ഀ \ 1 J~~ഀ i~~ Ql1ഀ 4 I` _ b''6 x WITH ~ 516 -q,.ഀ 01 ATഀ • 52 ~1~, 5•_6..~ ITH ~ EpGI-t ►^lP'Y 1ഀ CP 1 ! X1•_5.ഀ 1 1 Ep,GH Vim` TS 6X6X3pTഀ I I ~ ~ 0 1 I 5 - ~IINTERIOR I - ISTINGഀ EX NGRETEഀ I 1~ I r GOp~tING ~ഀ _ BEഀ O?N~ I I ~ ,I G3 1 i _ഀ - 1 I l (5i66 S) 6 Ali iഀ 7; 771ഀ GONG.ഀ I I STAIRS ~1 ` Q I ' c~ _ ~X 5•_6'ഀ I 1 - - y _ _ - 1 o6 AH Wp~rഀ Gഀ 1 1 _ 1 (8D,ഀ I I 8164'-0° I ~ ,ഀ 10,-61, ypTHഀ ~6 AT 5.. Y 1 1 , -o.. j 1 - Jഀ -IF 1ഀ I - = H ~ _ 1 '1 (t ~ '_I_ 5168 to'4,' ' 1 -ഀ 1 - --7--- 1=-----ഀ CO oosഀ ~ Iഀ I eq-^1 - \ഀ 71ഀ iഀ C 4-ഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C1ഀ HSS 1ഀ 6x6x.5ഀ Areaഀ 9.74ഀ in^2ഀ Ixഀ 48.2ഀ in^4ഀ Iyഀ 48.2ഀ in^4ഀ Sxഀ 16.1ഀ in^3ഀ Syഀ 16.1ഀ in^3ഀ Axial Loadഀ 69.93ഀ kipഀ x-x Loadഀ 12.61 `ഀ kipഀ y-y Loadഀ 24.72ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ 0.85 ;ഀ Kxlx/rxഀ 75.34ഀ Kyly/ryഀ 75.34ഀ Faxഀ 18.88ഀ ksiഀ faxഀ 7.18ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 4.31ഀ ksiഀ Fexഀ 26.31ഀ ksiഀ fa/Faxഀ 0.38ഀ Use H1-1 & Hഀ 1-2ഀ 1-11-1ഀ 1-11-2ഀ H1-3ഀ 0.87 < 1.0ഀ 0.68 < 1.0ഀ 0.80 < 1.0ഀ Column Size OKഀ Column Worksheetഀ For Axial Compression and Bendingഀ Fy 46 ksiഀ rx 2.23 inഀ ry 2.23 inഀ x-x e 2.50 in 5.50 in Total exഀ y-y e 2.50 in 5.50 ' in Total eyഀ x-x K 1.0 69.36 kip-in M max x-xഀ y-y K 1.0 135.96 kip-in M max y-yഀ Cc 111.6ഀ Fay 18.88 ksiഀ fay 7.18 ksiഀ Fby 30.36 ksiഀ fby 8.44 ksiഀ Fey 26.31 ksiഀ fa/Fay 0.38ഀ Use H1-1 & H1-2ഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ csഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C2, C4, C6ഀ HSSഀ 16x3x.375ഀ Areaഀ 5.48ഀ in^2ഀ Ixഀ 22.7ഀ in^4ഀ lyഀ 7.47ഀ in^4ഀ Sxഀ 7.57ഀ in A3ഀ Syഀ 4.98ഀ in^3ഀ Axial Loadഀ 68.78 'ഀ kipഀ x-x Loadഀ 0.00ഀ kipഀ y-y Loadഀ 0.00ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 82.35ഀ Kyly/ryഀ 143.59ഀ Faxഀ 17.68ഀ ksiഀ faxഀ 12.55ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ Fexഀ 22.02ഀ ksiഀ fa/Fax 0.71ഀ Use H1-1 & H1-2ഀ H1-1ഀ H1-2ഀ H1-3ഀ 0.71 < 1.0ഀ 0.45 < 1.0ഀ 0.71 < 1.0ഀ Column Size OKഀ rx 2.04 inഀ ry 1.17 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Fayഀ 7.24ഀ ksiഀ fayഀ 12.55ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Feyഀ 7.24ഀ ksiഀ fa/Fayഀ 1.73ഀ Useഀ H1-1 & H1-2ഀ Fy 46 ksiഀ 5.50 in Total exഀ 4.00 in Total eyഀ 0.00 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ CGഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C3ഀ HSSഀ 16x6x.375ഀ Areaഀ 7.58ഀ in^2ഀ Ixഀ 39.4ഀ in^4ഀ lyഀ 39.4ഀ in^4ഀ Sxഀ 13.1ഀ in^3ഀ Syഀ 13.1ഀ in^3ഀ Axial Loadഀ 92:32ഀ kipഀ x-x Loadഀ 4.83ഀ kipഀ y-y Loadഀ 0.00ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85.ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 73.68ഀ Kyly/ryഀ 73.68ഀ Fy 46 ksiഀ rx 2.28 inഀ ry 2.28 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Faxഀ 19.15ഀ ksiഀ Fayഀ 19.15ഀ ksiഀ faxഀ 12.18ഀ ksiഀ fayഀ 12.18ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbxഀ 2.03ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Fexഀ 27.50ഀ ksiഀ Feyഀ 27.50ഀ ksiഀ fa/Faxഀ 0.64ഀ fa/Fayഀ 0.64ഀ Useഀ H1-1 & H1-2ഀ Useഀ 1-11-1 & 1-11-2ഀ 1-11-1ഀ 0.74 < 1.0ഀ H1-2ഀ 0.51 < 1.0ഀ H1-3ഀ 0.70 < 1.0ഀ Column Size OKഀ 5.50 in Total exഀ 5.50 in Total eyഀ 26.57 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ U~ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C5, C7ഀ HSSഀ 16x6x.375ഀ {ഀ Areaഀ 7.58ഀ in^2ഀ Ixഀ 39.4ഀ in^4ഀ lyഀ 39.4ഀ in^4ഀ Sxഀ 13.1ഀ in^3ഀ Syഀ 13.1ഀ in^3ഀ Axial Loadഀ 62.86:ഀ kipഀ x-x Loadഀ 0.00ഀ kipഀ y-y Loadഀ 12.60ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 73.68ഀ Kyly/ryഀ 73.68ഀ Faxഀ 19.15ഀ ksiഀ faxഀ 8.29ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ Fexഀ 27.50ഀ ksiഀ fa/Faxഀ 0.43ഀ Use H1-1 & Hഀ 1-2ഀ H1-1ഀ 0.65 < 1.0ഀ H 1-2ഀ 0.47 < 1.0ഀ H1-3ഀ 0.61 <1.0ഀ Column Size OKഀ Fy 46 = ksiഀ rx 2.28 inഀ ry 2.28 inഀ x-x e 2.50 in 5.50 in Total exഀ y-y e 2.50 in 5.50 in Total eyഀ x-x K 1.0 0.00 kip-in M max x-xഀ y-y K 1.0 69.30 kip-in M max y-yഀ Cc .111.6ഀ Fay 19.15 ksiഀ fay 8.29 ksiഀ Fby 30.36 ksiഀ fby 5.29 ksiഀ Fey 27.50 ksiഀ fa/Fay -0.43ഀ Use H1-1 & H1-2ഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ r~"ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C8ഀ HSSഀ 16x6x.375ഀ Areaഀ 7.58ഀ in^2ഀ Ixഀ 39.4ഀ in^4ഀ lyഀ 39.4ഀ in^4ഀ Sxഀ 13.1ഀ in^3ഀ Syഀ 13.1ഀ in^3ഀ Axial Loadഀ . `84.76ഀ kipഀ x-x Loadഀ 0.00ഀ kipഀ y-y Loadഀ 0.00ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85-ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 73.68ഀ Kyly/ryഀ 73.68ഀ Fy 46 ksiഀ rx 2.28 inഀ ry 2.28 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Faxഀ 19.15ഀ ksiഀ Fayഀ 19.15ഀ ksiഀ faxഀ 11.18ഀ ksiഀ fayഀ 11.18ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Fexഀ 27.50ഀ ksiഀ Feyഀ 27.50ഀ ksiഀ fa/Faxഀ 0.58ഀ fa/Fayഀ 0.58ഀ Useഀ H1-1 & H1-2ഀ Useഀ H1-1 & H1-2ഀ 1-11-1ഀ 0.58 < 1.0ഀ H1-2ഀ 0.41 < 1.0ഀ H 1-3ഀ 0.58 < 1.0ഀ Column Size OKഀ 5.50ഀ in Total exഀ 5.50ഀ in Total eyഀ 0.00ഀ kip-in M max x-xഀ 0.00ഀ kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manual:ഀ C~ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C9ഀ HSSഀ 14x4x.25ഀ Areaഀ 3.37ഀ in^2ഀ Ixഀ 7.8ഀ in^4ഀ lyഀ 7.8ഀ in^4ഀ Sxഀ 3.9ഀ in^3ഀ Syഀ 3.9ഀ in^3ഀ Axial Loadഀ :`:11.48ഀ kipഀ x-x Loadഀ 1.02ഀ kipഀ y-y Loadഀ 1.00ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14,00ഀ ftഀ Cmxഀ 0:85 -ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 110.53ഀ Kyly/ryഀ 110.53ഀ Faxഀ 12.23ഀ ksiഀ faxഀ 3.41ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 1.18ഀ ksiഀ Fexഀ 12.22ഀ ksiഀ fa/Fax 0.28ഀ Use H1-1 & H1-2ഀ H1-1ഀ 0.37 < 1.0ഀ H1-2ഀ 0.20 < 1.0ഀ H 1-3ഀ 0.36 < 1.0ഀ Column Size OKഀ Fy 46 ksiഀ rx 1.52 inഀ ry 1.52 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Fay 12.23 ksiഀ fayഀ 3.41ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 1.15ഀ ksiഀ Feyഀ 12.22ഀ ksiഀ fa/Fayഀ 0.28ഀ Useഀ H1-1 & H1-2ഀ 4.50 in Total exഀ 4.50 in Total eyഀ 4.59 kip-in M max x-xഀ 4.50 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ C I'Dഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C20, C21, C22, C23, C37ഀ HSS 1ഀ 5x3x.25ഀ Areaഀ 3.37ഀ in^2ഀ Ixഀ 10.7ഀ in^4ഀ lyഀ 4.81ഀ in^4ഀ Sxഀ 4.29ഀ in^3ഀ Syഀ 3.2ഀ in^3ഀ Axial Loadഀ Iഀ lഀ k ipഀ x-x Loadഀ gഀ flഀ kipഀ y-y Loadഀ kipഀ x-x Lenഀ 12.00ഀ ftഀ y-y Lenഀ 12.00ഀ ftഀ Cmxഀ 0.85„ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 80.90ഀ Kyly/ryഀ 121.01ഀ Faxഀ 17.94ഀ ksiഀ faxഀ 3.62ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ Fexഀ 22.82ഀ ksiഀ fa/Fax 0.20ഀ Use H1-1 & H1-2ഀ 1-11-1ഀ 1-11-2ഀ 1-11-3ഀ 0.20 < 1.0ഀ 0.13 <1.0ഀ 0.20 < 1.0ഀ Column Size OKഀ Fy 46 ksiഀ rx 1.78 inഀ ry 1.19 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Fayഀ 10.20ഀ ksiഀ fayഀ 3.62ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Feyഀ 10.20ഀ ksiഀ fa/Fayഀ 0.36ഀ Useഀ H1-1 & H1-2ഀ 5.00 in Total exഀ 4.00 in Total eyഀ 0.00 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ C_1 k.ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C24ഀ HSS jഀ 5x3x.5ഀ Areaഀ 6.02ഀ in^2ഀ Ixഀ 16.4ഀ in^4ഀ lyഀ 7.14ഀ in^4ഀ Sxഀ 6.56ഀ in^3ഀ Syഀ 4.76ഀ in^3ഀ Axial Loadഀ 26.51ഀ kipഀ x-x Loadഀ rഀ 0.85ഀ kipഀ y-y Loadഀ kipഀ x-x Lenഀ 12.00ഀ ftഀ y-y Lenഀ 12.00ഀ ftഀ Cmxഀ 0:85ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 87.27ഀ Kyly/ryഀ 132.11ഀ Faxഀ 16.81ഀ ksiഀ faxഀ 4.40ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 8.27ഀ ksiഀ Fexഀ 19.61ഀ ksiഀ fa/Fax 0.26ഀ Use H1-1 & H1-2ഀ 1-11-1ഀ 1-11-2ഀ 1-11-3ഀ 0.56 < 1.0ഀ 0.43 < 1.0ഀ 0.53 < 1.0ഀ Column Size OKഀ Fy 46 k s iഀ rx 1.65 inഀ ry 1.09 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Fayഀ 8.56ഀ ksiഀ fayഀ 4.40ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Feyഀ 8.56ഀ ksiഀ fa/Fayഀ 0.51ഀ Useഀ 1-11-1 & 1-11-2ഀ 5.00 in Total exഀ 4.00 in Total eyഀ 54.25 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ CtZഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C28, C30, C31ഀ HSSഀ 14x4x.5ഀ Areaഀ 6.02ഀ in^2ഀ Ixഀ 11.9ഀ in^4ഀ lyഀ 11.9ഀ in^4ഀ Sxഀ 5.95ഀ in^3ഀ Syഀ 5.95ഀ in^3ഀ Axial Loadഀ 48.46ഀ kipഀ x-x Loadഀ 4.22ഀ kipഀ y-y Loadഀ 0.00ഀ kipഀ x-x Lenഀ 10.00ഀ ftഀ y-y Lenഀ 10.00ഀ ftഀ Cmxഀ 0.85 'ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 85.11ഀ Kyly/ryഀ 85.11ഀ Faxഀ 17.20ഀ ksiഀ faxഀ 8.05ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 3.19ഀ ksiഀ Fexഀ 20.62ഀ ksiഀ fa/Faxഀ 0.47ഀ Usഀ e 1-11-1 & 1-11-2ഀ H1-1ഀ 0.61 < 1.0ഀ H1-2ഀ 0.40 <1.0ഀ H 1-3ഀ 0.57 < 1.0ഀ Column Size OKഀ Column Worksheetഀ For Axial Compression and Bendingഀ Fy 46 ksiഀ rx 1.41 inഀ ry 1.41 inഀ x-x e 2.50 in 4.50 in Total exഀ y-y e 2.50 in 4.50 in Total eyഀ x-x K 1.0 18.99 kip-in M max x-xഀ y-y K 1.0 0.00 kip-in M max y-yഀ Cc 111.6ഀ Fay 17.20 ksiഀ fay 8.05 ksiഀ Fby 30.36 ksiഀ fby 0.00 ksiഀ Fey 20.62 ksiഀ fa/Fay 0.47ഀ Use H1-1 & H1-2ഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ e~~)ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C25, C26, C27, C29ഀ HSSഀ 14x4x.5ഀ Areaഀ 6.02ഀ in^2ഀ Ixഀ 11.9ഀ in^4ഀ lyഀ 11.9ഀ in^4ഀ Sxഀ 5.95ഀ in^3ഀ Syഀ 5.95ഀ in^3ഀ Axial Loadഀ 49.59 `ഀ kipഀ x-x Loadഀ 0.00ഀ kipഀ y-y Loadഀ 0.00ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ - 0.85ഀ Kxlx/rxഀ 119.15ഀ Kyly/ryഀ 119.15ഀ Faxഀ 10.52ഀ ksiഀ faxഀ 8.24ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ Fexഀ 10.52ഀ ksiഀ Fy 46 ksiഀ rx 1.41 inഀ ry 1.41 inഀ x-x e 2.50 in 4.50 in Total exഀ y-y e 2.50 in 4.50 in Total eyഀ x-x K 1.0 0.00 kip-in M max x-xഀ y-y K 1.0 0.00 kip-in M max y-yഀ Cc . 111.6ഀ Fay 10.52 ksiഀ fayഀ 8.24ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Feyഀ 10.52ഀ ksiഀ fa/Fax 0.78ഀ Use H1-1 & H1-2ഀ 1-11-1ഀ H1-2ഀ H1-3ഀ 0.78 < 1.0ഀ 0.30 < 1.0ഀ 0.78 < 1.0ഀ Column Size OKഀ fa/Fay - 0.78ഀ Use H1-1 & H1-2ഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ C) x-ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C32ഀ HSSഀ 16x3x,5ഀ Areaഀ 6.95ഀ in^2ഀ Ixഀ 26.8ഀ in^4ഀ lyഀ 8.65ഀ in A4ഀ Sxഀ 8.94ഀ in^3ഀ Syഀ 5.77ഀ in^3ഀ Axial Loadഀ 99.5 7ഀ kipഀ x-x Loadഀ tഀ 2ഀ kipഀ y-y Loadഀ 0ഀ kipഀ x-x Lenഀ 14,00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 85.71ഀ Kyly/ryഀ 150.00ഀ Faxഀ 17.09ഀ ksiഀ faxഀ 5.69ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 15.45ഀ ksiഀ Fexഀ 20.33ഀ ksiഀ fa/Fax 0.33ഀ Use H1-1 & H1-2ഀ 1-11-1ഀ H1-2ഀ H1-3ഀ 0.93 < 1.0ഀ 0.72 < 1.0ഀ ' 0.84 < 1.0ഀ Column Size OKഀ Fy 46 ksiഀ rx 1.96 inഀ ry 1.12 inഀ x-x e 2.50 in 5.50 in Total exഀ y-y e 2.50 in 4.00 in Total eyഀ x-x K 1.0 138.16 kip-in M max x-xഀ y-y K 1.0 0.00 kip-in M max y-yഀ Cc 111.6ഀ Fayഀ 6.64ഀ ksiഀ fayഀ 5.69ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Feyഀ 6.64ഀ ksiഀ fa/Fayഀ 0.86ഀ Useഀ H1-1 & H1-2ഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C33ഀ HSSഀ 15x3x.25ഀ Areaഀ 3.37ഀ in^2ഀ Ixഀ 10.7ഀ in^4ഀ lyഀ 4.81ഀ in^4ഀ Sxഀ 4.29 _ഀ in^3ഀ Syഀ 3.2ഀ in^3ഀ Axial Loadഀ ` 10.79ഀ kipഀ x-x Loadഀ 4.34ഀ kipഀ y-y Loadഀ 6.45ഀ kipഀ x-x Lenഀ 14.00ഀ ftഀ y-y Lenഀ 14.00ഀ ftഀ Cmxഀ 0.85ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 94.38ഀ Kyly/ryഀ 141.18ഀ Faxഀ 15.49ഀ ksiഀ faxഀ 3.20ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ fbxഀ 5.06ഀ ksiഀ Fexഀ 16.76ഀ ksiഀ fa/Fax 0.21ഀ Use H1-1 & H1-2ഀ H1-1ഀ 0.78 <1.0ഀ 1-11-2ഀ 0.55 <1.0ഀ H 1-3ഀ 0.64 < 1.0ഀ Column Size OKഀ rx 1.78 inഀ ry 1.19 inഀ x-x e 2.50 inഀ y-y e 2.50 inഀ x-x K 1.0ഀ y-y K 1.0ഀ Cc 111.6ഀ Fayഀ 7.49ഀ ksiഀ fayഀ 3.20ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbyഀ 8.06ഀ ksiഀ Feyഀ 7.49ഀ ksiഀ fa/Fayഀ 0.43ഀ Useഀ H1-1 & H1-2ഀ Fy 46 ksiഀ 5.00 in Total exഀ 4.00 in Total eyഀ 21.70 kip-in M max x-xഀ 25.80 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ c*ഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Column C34, C35ഀ HSSഀ 15x3x.5ഀ Areaഀ 6.02ഀ in^2ഀ Ixഀ 16.4ഀ in^4ഀ lyഀ 7.14ഀ in^4ഀ Sxഀ 6.56ഀ in^3ഀ Syഀ 4.76ഀ in^3ഀ Axial Loadഀ `'4Eഀ 52ഀ kipഀ x-x Loadഀ 0ഀ kipഀ y-y Loadഀ 0ഀ kipഀ x-x Lenഀ 10.00ഀ ftഀ y-y Lenഀ 10.00ഀ ftഀ Cmxഀ 0.85 'ഀ Cmyഀ 0.85ഀ Kxlx/rxഀ 72.73ഀ Kyly/ryഀ 110.09ഀ Fy 46 ksiഀ rx 1.65 inഀ ry 1.09 inഀ x-x e 2.50 inഀ y-y el , 2.50 inഀ x-x K 1.0ഀ y-y K 1.0_ഀ Cc 111.6ഀ Faxഀ 19.31ഀ ksiഀ Fayഀ 12.32ഀ ksiഀ faxഀ 7.06ഀ ksiഀ fayഀ 7.06ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Fexഀ 28.23ഀ ksiഀ Feyഀ 12.32ഀ ksiഀ fa/Faxഀ 0.37ഀ fa/Fayഀ 0.57ഀ Useഀ H1-1 & H1-2ഀ Useഀ H1-1 & H1-2ഀ H1-1ഀ H 1-2ഀ H 1-3ഀ 0.37 < 1.0ഀ 0.26 < 1.0ഀ 0.37 < 1.0ഀ Column Size OKഀ 5.00 in Total exഀ 4.00 in Total eyഀ 0.00 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ Column Worksheetഀ For Axial Compression and Bendingഀ Job Name: Vail's Front Door - Spaഀ M&N # 5500.02ഀ Columnഀ C36ഀ HSSഀ 5x3x.5ഀ Areaഀ 6.02ഀ in^2ഀ Ixഀ 16.4ഀ in^4ഀ rxഀ 1.65ഀ inഀ lyഀ 7.14ഀ in^4ഀ ryഀ 1.09ഀ inഀ Sxഀ 6.56ഀ in^3ഀ Syഀ 4.76ഀ in^3ഀ Axial Loadഀ 9 5ഀ kipഀ x-x Loadഀ FEഀ kipഀ x-x eഀ 2.50ഀ inഀ y-y Loadഀ 0ഀ kipഀ y-y eഀ _ 2.50ഀ inഀ x-x Lenഀ 10.00ഀ ftഀ x-x Kഀ 1.0ഀ y-y Lenഀ 10.00ഀ ftഀ y-y Kഀ 1.0ഀ Cmxഀ 0.85ഀ Cmyഀ 0.85-"ഀ Kxlx/rxഀ 72.73ഀ Ccഀ 111.6ഀ Kyly/ryഀ 110.09ഀ Faxഀ 19.31ഀ ksiഀ Fayഀ 12.32ഀ ksiഀ faxഀ 12.28ഀ ksiഀ fayഀ 12.28ഀ ksiഀ Fbxഀ 30.36ഀ ksiഀ Fbyഀ 30.36ഀ ksiഀ fbxഀ 0.00ഀ ksiഀ fbyഀ 0.00ഀ ksiഀ Fexഀ 28.23ഀ ksiഀ Feyഀ 12.32ഀ ksiഀ fa/Faxഀ 0.64ഀ fa/Fayഀ 1.00ഀ Use H1-1 & H1-2ഀ Use H1-1 & 1-11-2ഀ H1-1ഀ 1-11-2ഀ H 1-3ഀ 0.64 <1.0ഀ 0.45 < 1.0ഀ 0.64 < 1.0ഀ Column Size OKഀ Fy 46 ksiഀ 5.00 in Total exഀ 4.00 in Total eyഀ 0.00 kip-in M max x-xഀ 0.00 kip-in M max y-yഀ Please note that there mayഀ be differences in maximumഀ capacity compared to ASDഀ 9th edition. This is dueഀ to revised section proportiesഀ shown in HSS Connections Manualഀ Miscellaneous Designഀ 01/13/2006 08:51 9709494054 MONR~~OE~~ &~~NEWELL PAGE 01ഀ Monroe & Newell JOBഀ Engineers. Inc. SWEET NO. orഀ CALCULATED BY OATEഀ CHECKED BY DATEഀ "ONCT2W (anolowtI ZZS,I Ih3dd1ഀ 01/13/2006 08:51 9709494054ഀ MONROE & NEWELLഀ PAGE 02ഀ Ij FUഀ 2ഀ Monroe & Newellഀ JORഀ )ഀ Eng1IIeEF$, Inc.ഀ Aഀ SWEET NO.ഀ OFഀ ~ഀ CALCULATED BYഀ yyyഀ ഀ OATSഀ CHECKED BYഀ DATEഀ r ;ഀ iഀ rഀ iഀ iഀ SCALEഀ Iഀ rഀ Iഀ .ഀ 1- . ..A..........'ഀ ഀ . 1 1 .ഀ Iഀ VVഀ i . ' 'ഀ .ഀ ഀ Iഀ : Iഀ . A I . :ഀ ഀ 'ഀ Iഀ :ഀ Iഀ . rഀ ഀ ....I Iഀ ഀ 1ഀ Iഀ ഀ Iഀ 1ഀ Iഀ iഀ Iഀ 1ഀ ഀ Iഀ ഀ .aഀ .1...ഀ .~I 'ഀ ഀ C)8ഀ Iഀ ഀ ഀ I...ഀ 1ഀ ഀ ഀ .ഀ V \t1ഀ ഀ i ~.~I......... 1ഀ : iഀ ...i jl..ഀ 2Aഀ )i. ..I ....iഀ 1ഀ I iഀ t .1 I...... 1..........ഀ 'ഀ ഀ r.... . r..... ....1....ഀ ;ഀ 'ഀ ........:............1 ........i.............. 1.....,...ഀ .t....ഀ ഀ iഀ ഀ _ r ..........I.......... .ഀ rഀ Iഀ Lഀ fഀ lഀ I 1ഀ 1ഀ 1ഀ _ഀ `Aഀ ;gഀ . ter.ഀ Iഀ 'ഀ 1ഀ 1 1ഀ Iഀ rഀ 1ഀ i ~ I Iഀ Iഀ ഀ ഀ ഀ . .ഀ iIഀ ഀ ഀ Iഀ ..,.1.ഀ ഀ ഀ 1ഀ ..1, ..1.... i.......1.ഀ . . I..,....... Lഀ ~ ;ഀ I Iഀ ഀ I rഀ ഀ 1ഀ ഀ Iഀ . ..i..ഀ ഀ 1 .ഀ / lA.!ഀ J ..._.1.._..... _ഀ iഀ jഀ j Iഀ Iഀ Iഀ IIഀ 1 Iഀ 1ഀ ഀ I ~ r rഀ ഀ ഀ r r rഀ ~ ~ Iഀ Iഀ 4.ഀ 1 'ഀ ~ Iഀ I.ഀ 1ഀ .I i..ഀ ~ iഀ ..i.. I_..ഀ .ഀ ......_f.. I.ഀ ഀ ;ഀ i~ഀ ;ഀ ഀ ഀ ; i ;ഀ ഀ Iഀ 'ഀ 1ഀ iഀ i rഀ :ഀ 1ഀ Iഀ 'ഀ Iഀ Iഀ 1ഀ 1ഀ Iഀ ഀ I ~ , rഀ 1ഀ ഀ .ഀ ഀ . y~Vഀ ' . . .ഀ 'ഀ ഀ .I I.. I. F...~...ഀ . I.. Iഀ ഀ ഀ Iഀ 1 1ഀ Iഀ ~ഀ I ...1 I.ഀ 1..........ഀ Iഀ .ഀ I .ഀ ഀ ഀ .ഀ ' • . ~ rഀ . .ഀ iഀ I ~ I Iഀ I : ,ഀ .......V............ I......ഀ 7 ~ iഀ ~~/rte ~ഀ Iഀ ~j Iഀ Iഀ iഀ 'ഀ Iഀ 1ഀ r Iഀ Iഀ ഀ ഀ ഀ Iഀ 1ഀ Iഀ L.... j 1ഀ . 1 'ഀ I.......... I.,.... ..1...ഀ 1ഀ ഀ ഀ . ...1.ഀ ഀ rഀ Iഀ rഀ Ir.......ഀ ഀ 'ഀ .ഀ i....ഀ I . ...t :ഀ rഀ rഀ ' i.. ' ...1...... Iഀ ~ ! ~ഀ rഀ r r I I i ~ഀ iഀ ഀ ....I 1ഀ f • , ,ഀ i.... i....ഀ I I 1 1ഀ I.ഀ . I...ഀ l..ഀ ഀ ..iഀ iഀ iഀ 'ഀ .i....ഀ .ഀ rഀ ! ! ~ഀ I ;ഀ ;ഀ .........Aഀ . .ഀ 1.ഀ 1ഀ I I ..i..ഀ iഀ .i. .ഀ Iഀ :ഀ 1... i.. i. .i. .I........ഀ ഀ I 1ഀ I ,ഀ I fഀ Iഀ .4.. 1 .1,ഀ t jഀ Iഀ .i.. i..... .i.ഀ iഀ .ഀ ...Iഀ . ....I rഀ .I... 1 1ഀ Iഀ I.. I ....i.. .1 I....ഀ Iഀ Iഀ rഀ ....Iഀ I I Iഀ ........t I~... 1. ...1ഀ Iഀ ഀ 1ഀ P4000Cf 2Y-1 J"h ShMbpffs1(f",VIഀ 01/13/2006 08:51 9709494054 MONR~OE} & NEWELL PAGE 03ഀ Monroe & Newell JOBഀ Engineers, Inc. SHEET NO. 7 OFഀ 1JN ' CALCULATED B P DATEഀ V CHFCKED Byഀ DATF.ഀ SCALEഀ 01/13/2006 08:51 9709494054 MONROE & NEWELL PAGE 04ഀ A Monroe & Newell J08 ~AAr-ഀ Engineers, Inc, -SHEET NO, orഀ CALCULATED AY DATEiഀ CHECKED 6Y DATE.ഀ , _ -ഀ ;ഀ Iഀ i' Mഀ ' Iഀ ഀ p.ഀ ,ഀ I I I Iഀ ....r........... 'ഀ .............Iഀ MOOultm'l (Sl h6nrm)iro!-I odit7ഀ iഀ ,ഀ Iഀ i I ;ഀ 01/13/2006 08:51ഀ 9709494054ഀ Monroe & Newellഀ En ).nccrs. Inc.ഀ W.Dki'TAN-l dll drt90emvMS-l INdd.,ഀ MONROE & NEWELLഀ JOBഀ PAGE 05ഀ Y,_.A,- 5'ഀ SHEET NO. OF CALCULATED HY DATE ~ഀ CHECKED BY DATE _ഀ SCALEഀ 01/13/2006 00:51 9709494054 MONROE & NEWELL PAGE 06ഀ Q Monroe & Newell JOBഀ / Engineers. Inc. SHEET NO, ~ QF Ln/ഀ GAICULATED BY DATEIIG/ `ഀ CHECKED BY DATEഀ SCALEഀ 4y~~ഀ ,ഀ .ഀ .ഀ ഀ ,ഀ 7ഀ f_ഀ 1!.ഀ y i.ഀ L~ j .ഀ ഀ lZ J_ഀ tഀ ഀ ..iഀ w~ഀ i.ഀ -ഀ 1ഀ tiഀ ഀ ഀ ,ഀ ,ഀ