HomeMy WebLinkAboutB06-0018 � :
Community Development Department
75 South Frontage Road
Vail, Colorado USA 81657
CERTIFICATE OF OCCUPANCY
This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town
Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various
ordinances of the town regulating building construction or use for the following:
Name and description of project Vail's Front Door 3 Stor,�ge/Tunnel /Loading Dock
Address of project: 174 Gore Creek Drive V
Owner name and address: Lodge Properties Inc 174 Gore Creek Dr Vail,Co
IBC Edition: 2003 IBC Occupancy Group(s): S2 Type(s)of Construction: IA
Permit Number(s): B06-0018 Occupant Load:
!
Martin Haeberle, Chief Building Official
Sprinkler System Y/N Type: Y 13
-��z z �� �
Date
B06-0018: Entries for Item:90 - BLDG-Final 09:17 06/19/2013
Action Comments By Date Unique_
Ke
AP mgsafe 02/06/2009 A000122
713
Total Rows: 1
,
Page 1
�*********�*********************************************************+***********************
TOWN OF VAIL, COLORADOCopy Reprinted on 06-19-2013 at 09:17:34 06/19/2013
Statement
******************************************************�*****************************�*******
Statement Number: R070001061 Amount: $731. 89 06/22/200711:24 AM
Payment Method: Check Init: LT
Notation: Vail Resorts / ck
380554
-----------------------------------------------------------------------------
Permit No: B07-0164 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-2302-9
2101-082-7800-2
2101-082-8100-3
Site Address: 174 GORE CREEK DR VAIL
Location: VISTA BAHN OPERATOR SHELTER
Total Fees: $731. 89
This Payment: $731. 89 Total ALL Pmts: $731.89
Balance: $0.00
***********************************a********************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 441.75
PF 00100003112300 PLAN CHECK FEES 28� • 14
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B07-0164
Project#: PRJ06-0028
Job Address: 174 GORE CREEK DR VAIL Status . . . : FINAL
Location.....: VISTA BAHN OPERATOR SHELTER Applied . . : 06/OS/2007
Parcel No...: 210108223029 Issued . . : 06/22/2007
Expires . .: l 1/OS/2007
OWNER LODGE PROPERTIES INC 06/05/2007
PO BOX 7
VAIL
CO 81658
CONTRACTOR DOPPELMAYR CTEC INC. 06/05/2007 Phone: (801) 973-7977
3160 W. 500 SOUTH
� SALT LAKE CITY
UTAH 84104
License: 346-A
APPLICANT LODGE PROPERTIES INC 06/05/2007
PO BOX 7
VAIL
� CO 81658
Desciption:
CONSTRUCTION OF A NEW OPERATOR HOUSE FOR VISTA BAHN
Occupancy Type Factor Sq Feet Valuation
Totals . . . $30, 000 . 00*
TOV Adjusted Valuation: $30,000.00 Revision Valuation: $0.00 Revised Total Valuation: $$30,000.00
**s�**�rr�***s*�***�****�+*+x►*rr**********►�*+*******r►*��***+**»** FEE SUMMARY ********�►�**t******s****+***+***+r�***►*►►x��►t**�****+**+�
Building------> $441.75 Restuarant Plan Review--> $0.00 Total Calculated Fees---> $731.89
Plan Check---> $287.19 Recreation Fee--------------> S0.00 Additional Fees-----------> S0.00
lnvestigation-> S 0.00 TOTAL FEES-------------> $7 31.8 9 Total Permit Fee----------> $7 31.8 9
W ill Call-----> S 3.0 0 Payments------------------> S 7 31.8 9
BALANCE DUE---------> S0.00
**�**r++****�*�«»+****a�x**�*t**********»�***►*****�**�***�*++*w*********�x*r*�*****r***s►***r*rs*+*+*�r**********�*t«*****++*►********+r*******+
Approvals:
Item: 05100 BUILDING DEPARTMENT
06/12/2007 CDAVIS Action: AP Subject to field inspection
Shallow frost-protected footing design is approved for use in this project per the
IBC
sec 1805 .2 . 1/Exception.
This building has been determined to be a Importance Category I building
Item: 05400 PLANNING DEPARTMENT
06/05/2007 GR Action: AP
.**..*.*�«�....*...�..,...***�***.*.*.�...�*�»�*.,..�,�»*��*..*.�..**�..*.��.w++�*++....,:�,�*.*.�..�.�.�,:.».*,�,*..*.,�.�,�..,:+,:+...*.,:«,:+*.,.�.�,
See Conditions section of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFiCE FROM 8:00 AM
-4 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
i
1
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B07-Ol 64 as of 06-19-2013 Status: FINAL
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 06/OS/2007
Applicant: LODGE PROPERTIES INC Issued: 06/22/2007
To Expire: 11/OS/2007
Job Address: 174 GORE CREEK DR VAIL
Location: VISTA BAHN OPERATOR SHELTER
Parcel No: 210108223029
Description:
CONSTRUCTION OF A NEW OPERATOR HOUSE FOR VISTA BAHN
Conditions:
Cond: 1
(FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED.
Cond: 12
(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 14
(BLDG.): ALL PENETRATIONS 1N WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE
MATERIAL.
Cond: 17
(BLDG.): A STRUCTUAL ENGINEER WILL BE REQUIRED TO APPROVE ANY STRUCTUAL CHANGES BEFORE A FR�
INSPECTION IS APPROVED BY THE TOWN OF VAIL.
Cond: 20
(BLDG.): FIELD INSPECTIONS BY FIRE AND BUILDING DEPARTMENTS ARE REQUIRED TO CHECK FOR CODE
COMPLIANCE BEFORE BEING USED FOR OCCCUPANCY.
Cond: 31
(BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUN�
ON
COMBUSTIBLE FLOORING.
Cond: 34
(BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED
Cond: 35
(P.W.): ACCESS AND DRAINAGE INSPECTIONS MUST BE DONE BEFORE FOOTING INSPECTION.
Cond: 40
(BLDG): (MFR/COMM) FIRE ALARM REQUIRED PER NFPA 72.
Cond: 5
(PLAN): PRIOR TO THE TOWN BUILDING DEPARTMENT CONDUCTING A FRAMING INSPECTION, AN IMPROVEME
LOCATION CERTIFICATE(ILC) SHALL BE SUBMITTED TO THE DEPARTMENT OF COMMUNITY DEVELOPMENT A
MINIMUM
OF FORTY-EIGHT HOURS IN ADVANCE OF THE REQUESTED INSPECTION. ROOF RIDGES AND BUILDING FOOTPR
SHALL BE 1NDICATED ON THE ILC.
B07-0164: Entries for Item:90 - BLDG-Final 09:17 06/19/2013
Action Comments By Date Unique_
Ke
NO CANCEL JRM 11/02/2007 A000107
236
AP JRM 11l05/2007 A000107
237
Total Rows:2
Page 1
E06-0125: Entries for Item:190 - ELEC-Final 09:18 06/19/2013
Action Comments By Date Unique_
Ke
AP SHAHN 02/05/2009 A000122
676
AP mgsafe 02/06/2009 A000122
714
Total Rows: 2
i
Page 1
E06-0189: Entries for Item:190 - ELEC-Final 09:18 06/19/2013
Action Comments By Date Unique_
Ke
AP mgsafe 02/06/2009 A000122
715
Total Rows: 1
Page 1
E07-0289: Entries for Item:190 - ELEC-Final 09:18 06/19/2013
Action Comments By Date Unique_
Ke
AP METER AND FINAL OK shahn 10/31/2007 A000107
--____ --� ----- -_ – -------- 018 —
Total Rows: 1
Page 1
M06-0219: Entries for Item:390 - MECH-Final 09:18 06/19/2013
Action Comments By Date Unique_
Ke
AP mgsafe 02/06/2009 A000122
716
Total Rows: 1
Page 1
P06-0076: Entries for Item:290 - PLMB-Final 09:19 06/19/2013
Action Comments By Date Unique_
Ke
AP mgsafe 02/06/2009 A000122
717
Total Rows: 1
Page 1
��wn o��'ei�
. ���'�
� �
. �
������� i
Department of Community Deve%pment
Building Safety and Inspection Seivices
75 South Frontage Road
�ail, Co%rado 8165'7
970-479-2138
FAX 970-479-2452
www.vailgov,com
TEMPORARY CERTIFICATE OF OCCUPANCY
lst TCO 03/11/08
Seetion 110.3 of the 2003 edition of the International Building Code (IBC), as adopted by the Town of
Vail, reads as follows:
"The Building Official is authorized to issue a temporary certificate of occupancy before the
completion of the entire work covered by the permit, provided that such portion or portions
shall be occup�ied safely. The building official shall set a time period during which the
temporary certificate of occupancy is valid"
In accordance with the provisions noted above, the building constructed under Town of Vail Building
Permit
# B06-0018 and known as Building A/Parking and Delivery, located at 250 Vail Lane Vail,
Colorado, has been found to be in substantial conformance with the minimum requirements of the
Town of Vail Building Code and the provisions of Section 110.3 of the 2003 International Building
C (IB ) as ado the town, and is hereby authorized for use and occupancy on a temporary
asis.
?J�ll f�� � � 08
Charles E. Davis Date Acknowled ent by � � ate
Ch' � g Official, (print name) c� —
own of ail, Colorado Owner or Repre� sentativ
��
c nowledgement by ate
(pr� � u✓
General Contractor ��, ����L.����
Areas approved for occupancy:
Rooms: 103,104106,107,116, tunnel, loading dock, & Upper level parking
1 A Final Certificate of Occupancy is required to be obtained for Building Permit#B06-0018 by October
1, 2008.
2 Any violation of the terms of the Temporary Certificate of Occupancy will result in revocation of
occupancy per IBC 110.4.
F:\cdev\Building\Cert of Occ Temp\Frontdoor B06-0018.TC0.2008.DOC
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 06/O1/2006
Legal Description: rY�3C��o-UG�%� Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,659,000.00
CONSTRUCTION OF A 3 STORY UNDERGROiJND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
Totals. . . $27, 659, 000. 00*
Fireplace Information: Restricted: Y #of Gas Appliances: 0 #of Gas Logs: 0 J/of Wood Pellet: 0
****************************************************************�*** FEE SUMMARY **************************************�*********************
Building------> 1oz,914.lo Restuarant Plan Review--> $0.00 Total Calculated Fees---> 205,831:20
Plan Check---> 102,914.10 Recreation Fee--------------> $0.0o Additional Fees-----------> $36.00
Investigation-> $0.00 TOTAL FEES-------------> 205,831.20 Total Permit Fee----------> 205,867.20
Will Call----> $3.00 Payments-------------------> 205,867.20
BALANCE DUE---------> $0.00
*******+*********************�************�*************************************�****************�*****************�******�***�******************
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading, Excavatio:
Shoring only. Other approvals required prior to approval of full building permit.
approval
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON:
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for ex�
shoring and grading only. Addtional approvals required for building permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON:
Item: 05600 FIRE DEPAR.TMENT
05/30/2006 mvaughan Action: PA partial approval for grading and excavatio:
Requires fifty percent submittal in 30 days, 100 in sixty.
06/01/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON:
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
Item: 05550 ENGINEERING CIVILS
***********************************+**********************�*********�***�***********�*****************************�*�***************+*********�*�
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
-�-�... R� �,
SIGNATURE OF OWNER OR CONTRACTOR O H SELF AND OWNEF
PAGE 2
**�*��*�x****�*�:�x*��*���x��x�:**�:��*�:**�x****�:*�:***�x�***�:x**�**�x**�:**��:�x�:�x�:x��x**�*��*�:***�*�*��x�:�*��x�**��x**�x*
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 06-01-2006 Status: ISSUED
�*�x�*�:*�x*��:*�*�:*�*�x��x�*�:�***��*��:x**�:*�:**�*�:*��*****�**��****�*�:��x*�:���x�*�*�*�x�*�**��*��x***�:****�*�**�x*�
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 06/O1/2006
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
02-07-07; 11 :28AM; VAIL ;9703281791 # 2/ 2
� -.; „� � tiw�. u.s+�' � .
q "' ,. ..r . ' .'' �,,;, -�,..
� ,1� - � �
APPLICATION WILL NDT BE ACCEPTED iF INCOMPLETE OR UNSI O �2 �
Project#:
� � �O� Buiidin Permit#: � � $
�
. �
����� TOWN OF VAIL BUILDING PERMIT APPL CA �
I TION
_.—. ��.... - .�
Separate Permits are required for electrfcal� plumbing� mechanical� etc.l
75 S. Frontage Rd.
Vail, Colo�ado 81657 �
C�NTRACTOR INFORMATION
Ge eral Contractor: , Tvwn of Vail Reg, No.: Contact Person and Phone#'s;
Z p --,�4 1 v ,� � —�3C3
�mail address: �� ��„�„�M Fax#: C3d�� g'2S' ,�
Ccntractor Slgnature:
\
COMPLETE VALU S F UILDING PERMIT Labor&Materials
BUILDING:$ f d ELECI''RICAL:$ S° - O'fHER:$ .
PLUMBING:$ �' MECHANICAL:$ , - TOTAL:$ �7
For Parcel#Contact Ea /e Coun Assessors O�ce at 970-328-8640 or vlslt www.ea le-count .com
2,l �l O$mZ.��OO�
Job Name; , ,� � ��� •` Job Add�ess:
. �fql�.,�l /Cj20N/ ►�COjZ .��f
I.egal Des�riptlon Lot: ;� Block: Filing: Subdlvlsion; /�yy,� ��rf�
Owners Name:U ►ZFSoR�5 Add�ess:�3 7 M • Phone:�io �3�',2
.
ArchltecUDesigner: Address: �6Z) /S �,$`� �2, Lo Phone:(�j ,,2l2�Py �
Engineer:�� j���y, ��� Address•/�7! w'y+7it'ca� . EwN�it [o Phone: 623- � 7
Detailed description of work: 3 S�cZ✓ vNC�� I �� T 'R�r� �1.7' cG�t ��r, s
�cc�lss �i�n►ru���,.G�i .�y� .����. {�,� 1�/1�i-7Gl2Y.' I�M r?G�JrirM �C �
l� � TS� ���/4�U� ��4�i�S[r(��i:yl�'.�
Work Class: New( Addltion( ) Remodel( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior O Both(�'� Does an EHU exlst at this bcatfon: .Yes O No O
Type of Bldg.: Single-fiamlly( ) Two-femily( ) Multl-famlly( ) Cammerolal( Restaurent( ) Otl�ar( )
No.of Existing Dwelling Units in this building: No,of Accommodation Units in thls building:
No/7 e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnln
No/T e of Fire laces Pro osed:Gas A Ilances Gas Lo s Wood/Pellet Wood Burnln NOT ALL WED
Does a Fire Alarm Exist: Yes( No( ) Does a Fire Sprinkler System Exist: Yes( No( )
. FOR OFFICE USE ONL
1Y EYof�Coristruction':}i�?!k±�'ti:iTiifi'i�'��": �,?W:i;p a'c�.r;yt.y;,�;..., .:�.:. O
, . . �}.
;o_cc.�Panc�;G�..o'u,p:;�x�"�°::;: �,�;.;.:,����,�,,�.)';� ;,,,t :,�.A,,�,��.,,;.,.,. ,,,,..�.,:..,��.� FEB 0 7 20Q6
�,w.i�aVi4.4kn"'�it�?,��• �•AcceptedkBy....�'i;ib.,�,ni;'„T�3:i. .•+�;,:�`7.�'ty',
�U o �-��2 .
� � ' TOWN OF VAIL
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 07/14/2006
Legal Description: Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,659,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STOR.AGE/LOW HAZ (S2) ZONE 3 IA 115.18 108, 815$12, 533,311.70
Totals. . . 108, 815$27, 659, 000.00*
Fireplace Information: Restricted: Y 1l of Gas Appliances: 0 M of Gas Logs: 0 J/of Wood Pellet: 0
***********�***********�******************************************** FEE SUMMARY **��*******************************�*****�******************
Building------> 102,914.10 Restuarant Plan Review--> $o.00 Total Calculated Fees---> 205,831.20
Plan Check---> 102,914.10 Recreation Fee--------------> $0.0o Additional Fees-----------> $36.00
Investigation-> $0.00 TOTAL FEES-------------> 205,531.20 Total Permit Fee----------> 205,867.20
W ill Call-----> $3.0 0 Payments-------------------> 2 0 5,8 6 7.2 0
BALANCE DUE---------> $o.00
**��*****��**********�******��************�********�**********�***********�***********�**********************************************************
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading,
Excavation and
Shoring only. Other approvals required prior to approval of full building permit.
PW approval
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/il/2006 MROYER Action: AP Full building permit pending conditions
and other
department sign-offs.
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for
excavation,
shoring and grading only. Addtional approvals required for building permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/14/2006 George Action: AP
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and
excavation only.
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated
received
6/16/06 and 7/06/06
Item: 05550 ENGINEERING CIVILS
******************************************************+******************************************************************************************
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEP 49 OR AT OUR OFFICE FROM 8:00 AM-4
PM. �
\
SIGNAT RE OF OWNER TOR FOR HIMSELF AND OWNEF
PAGE 2
**�:�**�x**�x*�:**�x***********�*�*�*****�*�x***�:**�:�x***��:���x�**�x�***�:�*�**�:*�*�*:x***�x��x��*�x*�:****�**�:��*�:*�*�
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 07-14-2006 Status: ISSUED
�:**��**�:*�**�:***�x*�:*�**�x�x*�**�x*�*�x*�:*****�x�x*��x*�x***�x�x*�x*x:*�:***�*�*�*�*�*�:**�:��**��*��x��***�:*�:***�*�x*�x***
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 07/14/2006
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
��� �� ���
BUILDING PE1�;MIT MANUAL
BUILDING PERMIT:
B06-0018
CONTRACTOR: HYDER CONSTRUCTION
JOB NAME: VAILS FRONT DOOR
.IOB ADDRESS: SITE/B UILDING `A'
IMPORTANT DOCUMENTS ENCLOSED
INSPECTION PHONE # 4 7 9-214 9
THIS BOOK MUST REMAIN ON JOB SITE AT ALL TIMES
INSPECTION RECORD
BUILDING DEPARTMENT
Building Permit No. ��� Q�, �
TOWN OF VAIL
THIS CARD MUST BE POSTED ON JOB SITE AT ALL TIMES
Job Address V��I�S �(�� ��r Date Issued
Nature of Work /Ue�✓ Cd�►M vc�'a�- �
Use of Building W�,W�,C/'C �l-r Type of Construction
Owner L-.O�L ����t� �h=�-
Contractor � C�G� w'�3T '
INSPECTOR N1UST SICN A L SPACES PERTAINING TO THIS JOB •
INSPECTION DATE INSPECTOR REQ
Access (Public Works)
Culvert & Drainage (Public Works)
Above must be signed before any other inspections will occur.
Temporary power
Footings/Steel
Foundation/Steel
Weatherproofing
Foundation ILC
DO NOT place concrete until above has been
signed.
Electrical (Groundwork)
Plumbing (Groundwork)
Gas Piping (Groundwork)
DO NOT place floor until above has been signed.
Rough Electrical
Rough Plumbing/D.W.V.
Rough Plumbing/Water
Rough Gas Piping
Rough.Heating & Ventilation
Rough Driveway Grading/Slope
Rough Sprinkler
Rough Alarm Wiring
FRAMING ILC
Above must be signed prior to framing inspection.
Framing
Insulation
Sheet Rock Nail
Exterior Stucco Wire Nailing
DO NOT cover work until above has been signed.
Final Electric
Finai Plumbing
Finai Mechanical
Public Works TCO Approval
Pianning Dept TCO Approval
Fire Dept TCO Approyal
Building Dept TCO Approval
Public Works Final C/O Approval
Planning Dept Final C/O Approval
Fire Dept Final C/O Approval
Final Certificate of Occupancy
COMMENTS
REQUEST FOR TEMPORARY CERTIFICATE OF OCCUPANCY OR FINAL CERTIFICATE OF
OCCUPANCY MUST BE DONE IN PERSON. RETURN THIS BOOK TO THE COMMUNITY .
DEVELOPMENT DEPARTMENT TO REQUEST TCO OR FINAL C/O INSPECTION
$40.00 REPLACEMENT CHARGE FOR A LOST INSPECTION CARD.
FOR INSPECTIONS CALL 479-2149-24 HOURS IN ADVANCE - MONDLIY THROUGH FRIDAY
FOR FIRE DEPT. INSPECTIONS CALL 479-2252 48 HRS IN ADVANCE MONDAY-FRIDAY
*HIGHLIGFIED ITEMS REQUIRE INSPECTIONS*
� u
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI O .�2 �
Project#: �
Building Permit#
; a • oo �� � ��
m i . �
�����''�' y TOWN OF VAIL BUILDING PERMIT APPLICATION
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
CONTRACTOR INFORMATION
Ge erai Contractor: Town of Vail Reg. No.: Contact Person and Phone#'s:
2 4 -!4 � v fk�m so� C� $?.S�1313
Email address: ��h, �O +yu„�� Fax#: C3o�� g25' 3oZaZ
Contractor Signature:
�
COMPLETE VALU S F UILDING PERMIT Labor 8� Materiais
BUILDING: $ °�' '' 1�U ELECTRICAL: $ ���s���� � OTHER: $ ������
PLUMBING: $ �' MECHANICAL: $ � � , � TOTAL: $ �,7 ; ��' " i
For Parcel# Contact Ea le Coun Assessors O�ce at 970-328-8640 or visit www.ea le-count .com
����� �,� n i � ��.�����,Z
Job Name: , ..� � J�� f Job Address:
��42�.,S FzDn�/ I�bOfZ S��
/7
Legal Description Lot: � Block: Filing: Subdivision: �LL4 (,,��z��/�
Owners Name:U,�y ��SoRt 5 �� Address:�37 �3E /j'1 �- • Phone:CY?� -13��
► c.�s►.oaw�,vr
Architect/Designer: Address: �621 /S Si Ucir�e2, Go Phone:�3c?3 ,2�2�'33P3(
O c7
Engineer:��� �/i��,vE1�. �i�, Address:��/ GJyNA'ao1� • � �w`�'��Z Co Phone: 673- ;?7
Detailed description of work: � ��0,2-t-' �Nt�,�_c:c;��J ��`�', S�� T�� �-'�`-y� �-'-��`�-�'"`' �" -� `
��r*"�«hs ic;�rvnfr�L-�r�.>� �U 1'l,�-c"�- ,4.t,�. s��i1'c�cc�2r ��ar���U,�'�rr�.c�3 ���A�.,� 1.s4r��Scr���-�F
Work Class: New(r�} Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior'( ) Exterior( ) Both �-' Does an EHU exist at this location: .Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial(�estaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALL WED
Does a Fire Alarm Exist: Yes(r No ( ) Does a Fire Sprinkler System Exist: Yes ( No( )
FOR OFFICE USE ONLY
T e a#Construction: '�d� D
Oacupancy„�roup , ,_ � Accepted'��By: �Eg Q"� ���6
�V � V✓��rV�1. ' 1��� �� ����
�
F:\cdev\FORMS\PERMITS\Building\building_permit_1i-23-2005.DOC Page 1 of 14 11/23/2005
****************�***********�******************************************************�********
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R060000715 Amount: $138,973 .03 05/31/200609:06 AM
Payment Method: Check Init: JS
Notation: 53504/HYDER
CONST
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 205,867.20
This Payment: $138,973.03 Total ALL Pmts: 205,867.20
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 102,950.10
PF 00100003112300 PLAN CHECK FEES 36,019.93
WC 00100003112800 WILL CALL INSPECTION FEE 3 .00
-----------------------------------------------------------------------------
RECEIPT–The Town of Vail .,�� .� ',,
�� . 5'�'.�_4�
�� DATE ��� v"`� .20 ^�1� a�� ,...._ �..w,� i
i .� � '. f �,,v�y t�>d �
� � .�1,�/� � ,
� RECEIVED FROM � �
,
� ADDRF_SS `�
, �
...--
� � , ,, ,� �
�� a. ^ � L'V')_::., � %�.i�•'I i";('.% DOLLARS$��--'��JI i�
.� ..y�,
,
� i
,
� i
�
�
� �
; Police Receipt Numbers �
� Pernvt Numbers %r�-t1 �
� I� '- �. B %`Y ��111Y'.._-_��.1//�VI�.J�I.�j �
� HOW PAID—Cash Clleck�"�` '-' :.��' y
�,_,. ...._.._..___W_____�...._..__.._.._..___________.�__....__._�W.-_______..___________�_—__________,_ ,li
; r RECEIPT–Tl�e Town of Vail
� �� e���.'��
' DATE ►�',�,..�fl �n�.r.vt��}�_,20_���— �„�.... ,,.,. • ',
�� T 1�_ � �.�'i:� --d � a�,j�) -�� -1�-��� i
� RECEIVED FROM �♦ - /
,
�� ADDRESS �r- - �
� �
� . '� `'
', - %.,��-Y"'". � ,.�
a��
; ,DOLLARS$�r�')k�. !
, t ,
� _
�
�
�
, i
�� Poliee Receipt NumberS ,
Pernut Numbers -•'�
HOW PAID
—Cash Chec �-' �-� � ;� By f:.��"����`.....�`' t,,�,� �ir�r � —
� _
r
**�*�**********�**************�************�********+******+******�***+********�***�****�**�
TOWN OF VAIL, COLORADO Statement
**********************************************************************a�**+***************�**
Statement Number: R060000116 Amount: $38, 089.4702/10/200611:51 AM
Payment Method: Check Init: JS
Notation: 294235/VAIL
RESORTS-DAN FEENEY
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW CONIl�1 BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 169,811.27
This Payment: $38,089.47 Total ALL Pmts: $38,089.47
Balance: 131,721.80
��**�*****+******************************************************���x*****��****�*�*******�x*�
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 38, 089.47
-----------------------------------------------------------------------------
�**********************************�********************************************************
TOWN OF VAIL, COLORADO Statement
*:x**************************************************************��**************************
Statement Number: R060000140 Amount: $28,804.7002/16/200611:13 AM
Payment Method: Check Init: JS
Notation: 52915/HYDER
CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 169,811.27
This Payment: $28,804.70 Total ALL Pmts: $66,894.17
Balance: 102,917.10
********�x+**********************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 28,804.70
-----------------------------------------------------------------------------
VAIL'S FRONT DOOR
Vail,Colorado ---.
4240 Project No.20693.08 ��� � �6 � �
PROJECT DIRECTORY
OWNERS
Owner/Developer Vail Resorts Development Company Jack D.Hunn
FED-EX: Vice President—Development
137 Benchmark Road Dan Feeney*
Avon,CO 81620 Senior Project Manager—Construction
MAIL: Chris Walker
P.O.Box 959 Assistant to J.D:Hunn
Avon,CO 81620-0959
(970)845-2535
(970)845-2355 Direct/JDH
(970)845-2555 Fax/JDH
(970)376-0178 Cell/JDH
(970)845-2352 Direct/DF
(970)845-2358 Fax/DF
(970)390-6493 CeIU DF
(970) 845-2359 Direct/CW
j ackh@vailresorts.c om
dfeeney@vailresorts.com
chrisw@vailresorts.com
ARCHITECTS
Design Architect& Hart Howerton John Burkholder
Landscape Architect 0140 Ida Belle Drive Principal
Silver Mill Building, Suite F3 Mary Hart*
Keystone,CO 80435 Associate(Landscape)
MAIL:
P.O.Box 38(K61)
Keystone,CO 80435
(970)496-4552 Office
(970)496-4473 Fax
(970)389-3583/MH
jburkholder@harthowerton.com
mhart@harthowerton.com
Dennis Anderson Associates,Inc. Dennis Anderson
FED-EX: Landscape Architect
98 Aspen Glen Cart
Edwards,CO 81632
Mail:
P.O.Box 1387
Edwards,CO 81632
(970)926-7200 Office
(970)926-7201 Fax
(970)390-3745 Cell
daai@comcast.net
*-Main Contact Page 1 Last Revised: 9/26/OS
M:\Vail Front Door\Documents\Project Directo�y\Vail Front Door Directory-CURRENT.doc
VAIL'S FRONT DOOR
Vail,Colorado
4240 Project No.20693.08
Architect of Record 4240 Architecture,Inc. Robert E.Fitzgerald
1621 18th Street,Suite 200 Principal-in-Charge
Denver,CO 80202 Randall L.Hart*
(303)292-3388 Office Project Manager
(303)292-3113 Fax Pax Chagnon
rfitzgerald@4240arch.com Project Coordinator(The Residences)
rhart@4240arch.com Dan Reeves
pchagnon@4240arch.com Project Coordinator(Lodge at Vail)
dreeves@4240arch.com Jason Ringdahl
jringdahl@4240arch.com Project Coordirrator(Ski Club&Skier
Services)
Associate Architect- Glover Smith Bode,Inc. Larry Schwab*
Building A 1140 N.W. 63rd Street,Suite 500 Project Manager
Oklahoma City,OK 73116
(405)848-9549 Office
(405)848-9783 Fax
lschwab@gsb-inc.com
OWNER'S CONSULTANTS
Civil Engineer Aipine Engineering Glenn Palmer*
FED-EX: Project Manager
34510 Highway 6,Unit A-9 Bob Herbst
Edwards Business Center Project Engineer
Edwards,CO 81632
MAIL:
P.O.Box 97
Edwards,CO 81632
(970)926-3373 Office
(970)926-3390 Fax
(970)376-2734 Cell/GP
(970)376-2095 Cell/BH
paimer@alpinecivil.com
herbst@alpinecivil.com
Entitlement BAIBraun Associates,Inc. Tom Braun*
FED-EX: President
225 Main Street,Suite G2
Edwards,CO 81632
MAIL:
P.O.Box 2658
Edwards,CO 81632
(970)926-7575 Office
(970)926-7576 Fax
(970)376-3316 Cell
tom@braunassociates.com
Interior Slifer Designs,Inc. Sarah Carr*
DesiLner/Guestrooms,Ski 216 Main Street,Suite C-100 ProjectManager
Club&Residences P.O.Box 299
Edwards,CO 81632
(970)926-8200 Office
(970)569-3221 Fax
sarahc@sliferdesigns.com
*-Main Contact Page 2 Last Revised: 9/26/OS
M:\Vail Front DoorlDocumen[s�Project Directory\Vail Front Door Directory-CURRENT.doc
VAIL'S FRONT DOOR
Vail,Colorado
4240 Project No.20693.08
Leeal Otten,Johnson,Robinson,Neff&Ragonetti Bob Fisher*
950 Seventeenth Street, Suite 1600 Real Estate Law
Denver,CO 80202
(303)825-8400 Office
(303)825-6525 Fax
fish@ojrnr.com
Parkin�and Loadin� Watry Design,Inc. David(Dave)LoCoco*
1700 Seaport Blvd.,Suite 210 Principal
Redwood City,CA 94063 Matthew(Mat�)Sites
(650)298-8150 Office Parking Planner
(650)298-8151 Fax
dlococo@watrydesign.com
msites@watrydesign.com
Skier Services—Onerations SE Group Tom Allender*
FED-EX: Senior Associate
Mountain View Center II
610 Main Street
Frisco,CO 80443
MAIL:
PO Box 2729
Frisco,CO 80443
(970)668-3398 Office
(970)668-5798 Fax
(970)390-7809 Cell
allender@segrp.com
Skier Services—Joint- Gart Sports Tom Gart*
Venture Partners 233 Milwaukee Street
Denver,CO 80206
(303 333-1933
(303)270-0383 Fax
SSV/Specialty Sport Venture,LLC Kat Jobanputra*
233 Milwaukee Street Executive Vice President&COO
Denver,CO 80206
(303)270-0333
(303)270-0383 Fax
katj@ssnmail.com
Skier Services—Retail Trapp Associates
1980 8�'Street,Suite B
Boulder,CO 80302
(303)415-0036 Office
(303)415-0039 Fax
Soils Testing Koechlein Consulting Engineers William(Bill)Koechlein*
12364 West Alameda Parkway,Suite 115 Principal
Lakewood,CO 80226 Scott Myers
(303)989-1223 Office Senior Engineer
(303)989-0204 Fax
wkoechlein@kce-denver.com
smyers@kce-denver.com
•-Main Contact Page 3 Last Revised: 9/26/OS
- M:\Vail Front Door\Documrn[s�Project Directory\Vait Front Door Diroctory-CURRENT.doc
VAIL'S FRONT DOOR
Vail,Colorado
4240 Project No.20693.08
Survev Peak Land Consultants Inc. Brent Biggs*
1000 Lions Ridge Loop Principal
Vail,CO 81657 Mark Luna
(970)476-8644 Office Project Engineer
(970)476-8616 Fax
brent@peakland.net
luna@peakland.net
Traffic Kimley-Horn&Associates Inc. Curtis Rowe*
950 17`�Street,Suite 1050
Denver,CO 80202
(303)228-2300 Office
(303)446-8678 Fax
curtis.rowe@kiniley-horn.com
42�40 ARCHITECTURE CONSULTANTS
Acoustical Sonics,ESD Jim Barath*
130'/z Dunecrest Avenue President
Monterey,CA 93940
(831)646-9711 Office
(831)646-9780 Fax
(303)941-3602 Cell
jbarath@msn.com
jimbarath@comcast.net(for large files)
Code,Fire Alarm&Fire Rolf Jensen&Associates,Inc. Steve Rondinelli*
Protection 5460 South Quebec Street, Suite 370 Project Engineer
Greenwood Village,CO 80111
(303)573-7848 Office �
(303)573-7843 Fax
(303)598-3851 Cell
srondine lli@rj agroup.c om
Dewatering Jehn Engineering Matt Emmens*
5855 Wadsworth Bypass Project Engineer
Building A, Suite 100
Arvada,CO 80003
(303)423-6036 Office
(303)467-9438 Fax
memmens@j ehnengineering.com
Food Service&Laundrv Ricca Newmark Design A1 Moller*
6857 South Spruce Street Kitchen &Laundry
Centennial,CO 80112 Ralph Torres
(303)221-0500 Office Project Assistant
(303)221-0600 Fax
amoller@ricc anewmark.c om
rtorres@riccanewmark.com
*-Main Contact Page 4 Last Revised: 9/26/OS
� M:\Vail Front Door\Documen[s\Project DirectoryNail Front Door Directory-CURREN7'.doc
VAIL'S FRONT DOOR
' Vail,Colorado
4240 Project No.20693.08
Hardware Ingersoll-Rand Company Kevin Crook*
IR Security&Safety Consultants Hardware Consultant
7517 Quay Street
Arvada,CO 80003
(303)456-1201 Office
(303)423-1812 Fax
(720)480-9538 Cell
kevin crook@irco.com
Hvdrogeolo�ist Jehn Water Consultants,Inc. Jim Jehn* -
1565 Gilpin Street President
Denver,CO 80218 Gina Burke
(303)321-8335 Office SeniorProject Manager
(303)321-8346 Fax
jjehn@jehnwater.com
gburke @j ehnwater.com
Interior Designer-Spa& 4240 Architecture,Inc. Andrea Wood
Skier Services 1621 18th Street,Suite 200 Interiors Director
Denver,CO 80202 Pom Korkiat
(303)292-3388 Office Project Coordinator
(303)292-3113 Fax Travis Terry
awood@420arch.com Project Designer
pkorkiat@4240arch.com Cathy Smiley
tterry@4240arch.com Project Assistant
csmiley@4240arch.com
MEPFP Engineer ABS Consultants Marc Able
1530 16�'Street, Suite 400 Principal(Mechanical)
Denver,CO 80202 Jay Watson *
(303)623-6200 Office Project Manager(Mechanical)
(303)623-8435 Fax Ed Hornfeck
(303)725-7909 Cell/MA Project Engineer(Mechanical)
mable@absconsultants.com Tom Torzewski*
jwatson@absconsultants.com Project Manager(Electrical)
ehomfeck@absconsultants.com Dan Kozisek
ttorzewski@absconsultants.com Project Engineer(Power)
dkozisek@absconsultants.com Mike Rogers
mrogers@absconsultants.com Project Engineer(Lightin�
avaldez@absconsultants.com Alex Valdez*
Project Manager(Plumbin�
' Roo�ne Udall Architects,Inc. Gary Udall
Mailing Address: President
P.O.Box 475
Lafayette,CO 80026
FED-EX:
8022 Fo�idge Court
Boulder,CO 80301
(303)604-9199 Office
(303)666-4751 Fax
(303)918-8636 Cell
garyudall@comcast.net
*-Main Contact Page 5 Last Revised: 9l26/OS
- M�\Vaii Front Door\Documents\Project Directory\Vail Front Door Directory-CURAENT.doc
' VAIL'S FRONT DOOR
� Vail,Colorado
4240 Project No.20693.08
Structural En�ineer Monroe&Newell Engineers Peter Monroe,P.E.*
70 Benchmark Road,Suite 204 Principal/Project Engineer(Lodge at
PO Box 1597 Vail)
Avon,CO 81620
(970)949-7768 Office
(970)949-4054 Fax
avon@monroe-newell.com
Structural Engineer Monroe&Newell Engineers James Ness,P.E. *
1701 Wynkoop Street, Suite 200 Project Manager/Project Engineer(Ski
Denver,CO 80202 Club&Skier Services)
(303)623-4927 Office Sheri Weiland
(303)623-6602 Fax Project Engineer(Residences)
denver@monroe-newell.com Nicole Lane
Project Engineer
(Tunnel/Garage/Loading Dock)
Curt Hattel
AutoCAD Administrator
Monroe&Newell Engineers Mark Gee*
619 Main Street,#7 Project Engineer(Residences)
P.O.Box 295
Frisco,CO 80443
(970)668-3776 Office
(970)668-3789 Fax
frisco@monroe-newell.com
Structural`Fill'En�ineer Advanced Engineering Solutions Marvin Cook*
754 North 4275 West President
Cedar City,UT 84720
(435)867-1083 Office
(435)867-8866 Fax
(435)590-0000 Cell
coolang@aes-advengsol.com
Vertical Transuortation Lerch,Bates&Associates Scott Shepler
7899 South Lincoln Court,Suite 204 Regional Manager
Littleton,CO 80122 Jeff Marsh*
(720)283-8182 Office Project Manager
(720)283-8184 Fax
sshepler@lerchbates.com
j marsh@lerchbate s.com
Water Feature STO Design Group,Inc. Desmond Stevens
2500 Redhill Ave.,Suite 205 Principal
Santa Ana,CA 92705 Andrew Woods*
(949)476-8729 Office Senior Project Manager
(949)476-5048 Fax
sto@stodesign.com
andrew@stodesign.com
*-Main ContaM Page fi Last Revised: 9/26/OS
� M:\Vail Front Door\Documents�Project Directory\Vail Front Door Directory-CURRENT.doc
VAIL'S FRONT DOOR
Vail,Colorado
4240 Project No.20693.08
Waterproofn� Building Consultants&Engineers,Inc. Chris Morgan,P.E.*
1520 West Canal Court,Suite 240 Architect/Engineer
Littleton,CO 80120
(303)350-1000 Office
(303)350-1004 Fax
(303)815-3488 Cell
chris @building-c-e.com
PRECONSTRUCTION SERVICES
General Contractor Hyder Construction,Inc. Tom N.McLagan
543 Santa Fe Drive President
Denver,CO 80204 Doug Thompson*
(303)825-1313 Project Manager
(303)825-3223 Fax Wally W.Goodnow
(720)932-3262 Direct/TM Senior Estimator
(720)932-3264 Direct/DT
(720)932-3269 Direct/WG
(303)829-5950 Cell/DT
tmc lagan@hyderinc.com
dthompson@hyderinc.com
wgoo dnow@hyderinc.com
*-Main Contact Page 7 Last Revised: 9/26/OS
� M:\Vail Front Door\Documents�Project Directory\Vail Front Door Dvectory-CURRENT.doc
. - 4�U� T ��Iv
�tS
��.� C��'Y
u...:ti�� � ,�
.��.���:..�, ��_
�;. :..f:.
�`� -°,-,�
��
�t�;�Q�`�{�0, ��� :���?11�..
AGENCY ��,�� �� ����
- .� !,5±� . ��
May 26,2006
Charlie Davis,Building Official
Town of Vail Community Development
75 South Frontage Road,Vail, CO 81657
RE: Front Door Grading and Excavation Permit
Charlie:
Colorado Inspection Agency has reviewed the documents submitted as requested from the
meeting and comment letter dated OS/18/2006. These documents were reviewed for compliance
far the release and approval of Grading, Excavation and Shoring of the Front Doar Project Site.
The documents submitted have clarified the outstanding issues that were identified by Colorado
Inspection Agency and Town of Vail Building, Planning, Public Works and Fire Department.
Conditions of this approval to allow grading,excavation and shoring are as follows:
1. This approval is for grading, excavation and shoring of the site. Permits which are
granted partial approval for this work are B06-0018,B06-0022.
2. Additional plan review fees will be assessed to these permits and payment is required
prior to release of permit. Email regarding the additional fees has been included with this
document.
3. Complete Building permit fees for permit B06-0018 and B06-0022 will need to be paid
prior to release of grading and excavation permit.
4. Submittal dates for remainder of plan review comments and full building permit approval
have been established by Vail Resorts. The letter stating the dates has been included with
this document for reference.
a. Complete VFD Building A,B, C &D response will be submitted for review no
later than June 19, 2006.
b. Complete VFD Building E response will be submitted for review no later than
July 10, 2006.
5. Reference to the International Residential Code needs to be removed from the Ftre and
Life Safety Report and Administrative Modification for the Building E-Chalets. Page
12, 13 and 16 all make reference to this code of which is not applicable. This was
discussed with Steve Rondinelli on May 26, 2006 and agreement was made that this
FLS/Admin Mod. will be modified with the full building permit submittal to reference
section 708 of the International Building Code.
Colorado Inspection Agency p:970.328.1790
1286 Chambers Avenue,#l01 f:970.328.1791
Eagle,Colorado 81631
- 1 -
Colarado Inspection Agency recommends approval to move forward with Grading, Excavation
and Shoring with the submittal dates and conditions listed above. There are several issues still
remaining to be resolved prior to release of a full building permit.
Please do not hesitate to contact me with any question ar clarification.
Sincerely,
Matthew Royer, Building Official
matt.royer@coinspect.com
Colorado Inspection Agency p:970.328.1790
1286 Chambers Avenue,#101 f:970328.1791
Eagle,Colorado 81631
-2 -
.—�. �
�.� �
�t:��,°':5 �?itl(�
���-, �;k:.�t•l�4 D<��i�.
��i12c�: ��i1i�w}IT��' �)�i1�t�t�
Tc�;�i. t.t � titl {,..i.atT?itttiT,iC�'�i'��';C)t�t�lb�lu
�� �si)taCl� �'l'i7�11;1�?;` EZ�3.i��
'�'�iil. CC:� ��t��•zv.
I�5'.1::: �'.a��'� �=t�?s1C C)c.�t��'i''�,�Lwt
t'�bx�� C"}t;:c:.i� I��:,g��aa:��t-`i,i.xj� I.lr��
C 3�,tr�.��.t;?i�,
S�i:.' qhtt("�?t)"�G' ti. !(ti:+ �t.)i!":.':+�?t)£tia�'il�'i'. 1� �t�t t�t::�E:1t I�1;: i�1t,c.iliii`, t�t�:i �`�k���.'. ��1f°f,tl�:;�l t�la«
.�Ft;ll;,'�� [j���it'il?1"l� t�=��,� :� i�s1Ct:".S::SIiK'�,'y 1�.'.�� E�t`. ;iCi�^1�7dICti1�,? C1:�-�"'t7["S:;tG:;� IC>T���:`�`�.'Gt:��li.� YC?kttzl:�
�'±t �'xFii. � ilti:�s •.t?It73�:tTF:�. ��1�'tit+i?�k'.�T (}s.Ili 1.T31t;C:�s �t�;ll€1?�ItCti �tti#;; i�:`�1�`�'i� a#I't?t2:1 ��.�.:�..
�}4tti�=�c:�1 t=;��.3�� �,t�iy � z�: �Ic;€��f.t� �6���, �, ?(��)ti.
(t ��; �:�til'i��s;zttitafl tc� ��.'i�t���l� cl���:c: t�ct-�t:at���?�:� `E�rao��z�,�;:; .tf��: E�.i:;t>�.�c���,' �tc:�at;:��; ".4?r
tt�� ;���Ci�:i����C�.�' �:i:,ak}�ii«��.�ir.�c.h���� �>�.t'����tts�r�:cti�� ��� '����tit Ftic�;�et°vt�t�.E..<'�. �.��� }-`c:ti Er:�iry•�,..
ttls�: t���� a �r�;IL��L?r��,c�.��.��a� '.<�. ���I��Ci {�;�itEt��:€��±.°c�l`t�7�;tr��r.�xt;itt�al tc� �°c��� G,#:tl:��t
�ttt�e,i� l!�: k•.,t�cr�i,c�, :�ili��:; �c� �t��:+»c�tt�l�:rt��:�i 1,,s ��:'�t�:t��:� r�'��ir�t�Fat����'�t�i;:C's.�t,��*i�;
��ilt�t`;±�9�1ti' '��itti �`�, �`q.)t,}f)_ �'.Z �tr..� C'7�:tt.C'T:;tJ� ,'���t4` ��, ti��fa[?, �t t�(�,�(`il(1i,�:t"St:.tl�'�Ii�t; t�'lElC tk�
�E.� �c��3�s7��:t�¢ rc�;��i�is��; ztr°� ,��i:,�tr�l�lc: ;i��e�tl��t �t�:i��5 r�:��t�c,t�ci {�,°i� �:���;az? �'[�r,.�a�3 .
I�:4:}€"�('�t`� k��` t'i��xa t�a:��rfY�l,Tt.�`�' l��a{�.�i���:c;r, <�rt ;;v�t�,Ei��l. �kas�. Ga 1;�:�:��-.zti��ct ��r���l..i�=
�'�°€`.��it��;9) !a� ��;,t��c3 f�i��-t�`I�C� L�a luit���� .� �C::�, ia�� i?:-la�ti�.� 114i�•:s���. �'�tlti.
�„�i?i:t�7�...w �"`i�ll: �_�1��:�': {�,t)iliz1zt11C� �i?!' �:��'�,) ��1161#�tElis�+;'�. �3. �, x;i. �� 111i:.i?`� ;,1.°?t:3isCE'.'i+ ;t:l
�.��.i�-t7t �ci: ��:i i.��� 1�:����-e. J.,t��w ��), T(3i���. l'Pti�C� is it����tt�al tl��st ;��4 1'.i!1 I3�iil�l�al,:.y` �.}..c�fts�;�
tt1(' E�?. t�i,'xi:;?ti :�, ��., �_ 4� ��� E4t�P ;�.. 1341i';;"(� 1's1 :t €YI1i��.` t1t:7f�li�:C. `>l? ��4'{��;t'�.C?[7;,II'?zti'Ii11:1 L:1=]
t��aaa�,�a�it� =,lti:,.c�r�.�e�a�.�i���; ;��t��:ai�.�l�. 'l'��I�C ����ta��1 ��;t'�:�*{R. ;�p���t ^c�:�t�. t:t�: r�l�:<�,�-ijt't����
fi�:i=�t:it�� I'�rtr�ii tibt' E3�tililiti;= �3 ki:�,c. tw:� a���g��:! ��.I�:�i1�z��° �a;�3�.�c.t� �+�:a'�� I��=�:�':=�t;��, ,��,, C" ��. t:)
t�.� ��a�_?u�x..
E i.�k�,l;,', i4 t5 ��:t�r Az�r.�;r:t t�> 4�tta:i�it c�r:f��?l;�t�: i�l,�it t_1.4�1: r�,;,t��.�.,:y ti.r I.�ti�lt:lig��,� k::, ��t, ��r-
���f�2I'i� .i�ti°,` ��), ?fli�d5. ��}ltt.'['s::�:T� ;�c`��i t�lc;�3i���itic�ic:ix $�tI1�, tf) :�tY�?t1�1t �3L,1�c.:tE,A �.,. �:�;,��:t��4�
G�� :�t:�iT�:s;f���� �:�srAi;�:rEtS ��c�l.�:��i t�� It�C.` C::`lz��f,i�s° I i �4��tt�°� ��c�:�ri .zE;�ci G'�a�G:�,�cl ir4 c��ir
ti7c:C;i:Tle� t3� ��t� �`i. �.�.�.S�.T(1. :�.°� 31(.?�L�i il�`zt��l't '4��1�.)t., :.'i i3I3TE�I�>e7�ll':��k�S��it.'��lti."itt�`(It lz'3l
�'�:s°ca�st� fi:=r t3��}�:�>_ �::.
�.,...A, �Y-n,^,�'RF..s..
...t� � ., � y .t . I KY . . 'ti,i�� �. .,., � � �., � ,.. � ,, � . �. ... �...>Fs t. , i _. ._.. i<; :S( ,. � .
ti.z.. � ,. . .. . , T. � . � ,, a �� . i t ..._
. _i ..E. t��. a> . ._... - #a� . ... + .. {i.,'.. t �... E .�f, ,.�... ��v
��M.�,.,..�,�""�,,,��-..
VAC �, RESrC}R'F,'�.>'
£�_ro_ _�. _ .
) 1d s, y' { ( ,
� �4..�/C w�C'tJt,S�.�x)i'�� ,�>,zs,.�r�,+i�:S.C.'4,4.�ii�i.k�4�fiyn �i`�d�,��;a f.L'wl �Z« ii�±�z `. i'•i;:v.�k, ..��,. _�..kx k,c:3}�w..`+ 4�5 �'�>�C,�.�,� i,.;,..
`v,Fa`:l},:� �3'ai�{x �.. ?14'.4:�': �c,�i'?t'is``.'� ;it?`�.;.w ���;,.�5:�> r.:,.a ..!1°t 1_�i..�,z�..:.:i.. �I.:��.iB 1^.: Lr'��:Sai"�li i>� a�.�l. �i:� .
E�3�v �T14i L�n�� � 3 i � ex�,. 3`� . Y SFi s. �� .� _a. t' ')��� �i ai � i,. 1'F � , fE� Y i � �•
.�.xx � t ars� i'vri[�€ieJ "€�_� ��;a..'C.a. L t3 6.�� ,s:..��� <�.,x .� �# ,. rk��i��C. � � c.�< �.,��'- ki.d .. .�;,
�.:#'rIi'1 ;�2At� 1'�i�: .il>�� t'1;:. 4:)�€]t't' �(,)� {���It'I:i�^� Ft.11"c'. t;';�t"1".tlt�i� �ti? bfci.' ��;'{,#�ii:� =l? :�'+E);t".tl'-r
.`,Y��dIX:.�. ��dt�5����...�.Aaa,..Ai�i# �\,'Zl.{..� �•��Y1niStit.�.4�t i*,Ox.e.tx.5 iq�.L.k•�.].iliG�i.v.•{.+M1 �=�.n�.F.�i¢L'4. .i�i..4���{ft.,{ �L�,d5 �1a��'i. .�.4�:�::
t�..:_`w%la)33ti t�t rv�.�ci::°'� a3k>l�l�i:t)c.�z: II>r�ri,7....:� E� .,.;:: �i";'c.' >a? ��aTil�:@i,s :l:t: �i t"�-.CM sa� .
Er�$.g.�3�'...'."°... $.S:'�.• E.�)�`_',€��.1, j .. A , '? � e � �.'<!. ,; :` i � .�.,i
1 '� g t t .
.. _ . . Y s�:x_": _iC�eC',�l'.ti� li:�. � c��C'sS�„e�.�:� . F _. ...t�: t�i{ a s�z��`,`
t
v:l`%::l€�;7'tt4<B�.i» . ���iF'�. 4t:j�t3t;� 4�a'�' it's tl��i��ia i�"�+:?i; t"i'��li�^�1.
� `" ° � �� �r �e���'
:.,_ � e � - �r 4:��:: .��;.9i� "s
�° , � �. E•°s
�`� � �+ �.�+.� 7 �'i t�axs�,T?��ii-'�S{�.a
�.�����`�y 1"��%��""°�+ 4 ' t }l.:e$7t.i�� �':� lt� °t�^���P .
� z f
��}�'��, �.1Lt��A:�. :�SF,It �ti�,i�t �\ai .'`{_�_;'�
.'��r) E�i,c��'t�, L)��U.:i� ��.>�}.t; C�c�. �.;.°{� i��:.ts�r��t"��?�" �'ia�..r�€i:
��_� .�: ���� t�s�:i."�f?� �����: _.
f..,,s4 .1.� i?: �`3l�.ti3.�'*:i: 4�:..��` s�'�tt,.
� �'!{Xti: ,1�:L'�,?C:C%"�� c".�.:,:1
�
$..1
Matt Royer
From: Charlie Davis (CDavis@vailgov.com]
Sent: Thursday, May 18, 2006 4:09 PM
To: dthompson@hyderinc.com; JACKH@vailresorts.com; rcaudel@vailresorts.com
Cc: Matt Royer; Joseph Suther
Subject: Assesed Fast Track Fees For Front Door
Good Afternoon,
As promised here is the breakdown of additional fees that we discussed in this mornings
meeting. Due to the fact that a request has been made to release partial permits for
excavation and shoring work, we have assessed a fast track fee on the following:
B06-0018 Building "A" permit
Current plan check fee = $66, 894. 17
Fast Track plan check fee = $102, 914 .10 Fees paid to date = $66, 894 . 17 Balance due at
time of partial permit release = $138, 973.03 (excludes rec. amenities fee)
B06-0022 Building "E" master permit
Current plan check fee = $10, 087.02
Fast Track plan check fee = $15, 518.50
Fees paid to date = $10, 087.02
Balance due at time of partial release = $19, 452. 98 (excludes rec.
amenities fee)
The good news is: We only need to assess this fee on the two above listed permits and not
the nine permits that was discussed this morning.
Thank you all for your cooperation this morning. It was a pleasure to work through these
difficult issues without any additional burdens.
Please contact me with any questions.
Best Regards,
Charlie Davis
Chief Building Official �
Town of Vail
970-479-2142
cdavis@vailgov.com
1
,-- �_ - _ -.. _.-
Charlie Davis- Front Door Page 1
From: George Ruther
To: Charlie Davis
Date: 05/17/2006 1:43:16 PM
Subject: Front Door
Chuck-
I am comfortable with the issuance of a grading permit for the Front Door project. I reviewed the staging
plan submitted back in February and have no issues with the staging plan. Given the scope of the work, I
am not requiring a bond at this point.
The full permit can not be issued until the appropriate conditions of PEC approval have been met and the
revised changes to approved plans DRB application has been approved. I am working with the applicant
on getting the PEC issues finalized. I have the DRB application for review. At this point my contact
persons with Vail Resorts, Jay Peterson, Tiom Braun and Bob Fitzgerald, all know of the issues to be
addressed.
See you at the 9:30 am meeting tomorrow.
Thanks,
George Ruther, AICP
Chief of Planning
Town of Vail
(970)479-2145 office
(970)376-2675 cell
(970)479-2452 fax
gruther@vailgov.com
' FV�': B06-0018 - Shoring Plan Review Camments Responses Page 1 of 2
`.-' ��'�if� �p:�i" �� �"
Matt Royer � _-- '�' �tl "' `O 11 ,.Uai�
.
� �_�_� _ �__.,� �_�����,.�...� __r_�.. ���w,. __..��.�. ___�
���� �� �
---------' :" g.,� .
From: James Horne [jhorne@klaa.com] 4;'�� � , �
� ���
Sent: Wednesday, May 24, 2006 8:42 AM � t;� s� " ���� ��
� �� x
To: Matt Royer
Subject: RE: 606-0018-Shoring Plan Review Comments Responses
Follow Up Flag: Follow up
Flag Status: Red
Matt, all of the structural comments for the shoring package are closed, Hyder's response as far as coordination
with the design team has answered my comment#3. Schnabei will coordinate the other items as required in their
responses. It seems to me that there are no substantial changes to their drawings that would require them to
resubmit their drawings or calculations to the city, at least as far as the structural comments.
Please let me know if you need further documentation for the shoring package review.
Thank you, James
From: Matt Royer [mailto:matt.royer@coinspect.com]
Sent: Tuesday, May 23, 2006 2:53 PM
To: James Horne
Subject: FW: 606-0018 - Shoring Plan Review Comments Responses
Matthew Royer
Building Official
Colorado Inspection Agency
877-428-6412 Ai�PROVED
970-328-1790 Subject to inspection and Compliance to aA
970-904-0460 relevant Adopted Building and Municipal Codes.
matt.royer@coi n spect.com
Chan es in Plans MUST e approved.
www.coinspect.com Date . . �.,@y.�. __�
__ _
��. e_.� M._�_.�_ ___ �.__�_. ��__ ....�. � ���_�. .M.� ..__.� � �._-���� �. �..._wZ�� ���.. __�,. ._._
From: Doug Thompson [mailto:dthompson@hyderinc.com] ��I@F@�� fl��—� ���I�fl A��Fl�y
Sent: Tuesday, May 23, 2006 3:37 PM $a�D-pb�8
To: Matt Royer
Subject: FW: 606-0018 - Shoring Plan Review Comments Responses
Matt,
REViEWED BY
Let me know if this get through ok?
ooug MAY 2 6 Z�06
COLORADO INSPECTION
From: Doug Thompson AGENCY
Sent: Tuesday, May 23,2006 11:25 AM
To: 'Matt Royer'
Cc: 'Charlie Davis'; Randy Hart;'Richard"Rick"CaudeP
Subject: 806-0018-Shoring Plan Review Comments Responses
5/26/2006
,xsv.w�.����%.r��.
� :'4:� .�..,�..Wy� , �'e.
�.;�.,�, %�,;� �'��'a'u'����.
�,�.;,��'«';m� �.3�`.s�.
�-�. „�
`` ,;;
���+���`����i�k� ��:�ic�r�
r.�._= ..r �rr .��ur1.`.
AGENCY
COLORADO INSPECTION AGENCY PLAN REVIEW COMMENTS
TO: Contractor Architect Enqineer
Hyder Construction 4220 Monroe & Newell Eng
Doug Thompson Randy Hart
EMAIL: dthomson(a�hvderinc.com rhartCa�4240arch.com
FAX #:
NUMBER OF PAGES: 3 �
FROM: Matthew Royer
DATE: 05/17/2006
BUILDING PERMIT#: 606-0018-Shoring Only
OWNERS NAME: Vail Resorts Co.
SITE ADDRESS: Building A and Site
SUBDIVISION: Mill Creek
OCCUPANCY GROUP: S-2
TYPE OF CONSTRUCTION: I-A
NUMBER OF STORIES: 3
The design documents submitted for this project have been reviewed for compliance with the locally
adopted codes and amendments. The following comments must be addressed before a building
permit is issued.
For processing:
. Please submit (5) complete sets of revised construction documents containinq the repuested
information or plan revisions with all revisions clouded or otherwise idenfi�ed.
. Please respond in writinq to each comment bv markinq the attached list or creatinq a
response letter. Indicate which plan sheet, detail, specification, or calculation shows the
reauested information. Please send revisions to the attention of the plans examiner with the
buildinq permit application number noted.
Responses such as "will comply with code" are not adequate. Revised drawings must
clearly show code compliance.
A RESPONSE LETTER MUST BE INCLUDED WITH THE REVISED PLAN SUBMITTAL.
. Please be sure to include on the resubmittal the enqineer's or architect's "wet" stamp, sianature,
re4istration number and date on the cover paqe of anv structural calculations, all structural details
and structural sheets of the plans. For commercial or multi-family proiects all sheets of the plans
must be stamped.
C:\Documents and Settings�mroyerVvly Documents\Plan Review\Front Door\tov-b06-0018.Shoring.DOC Page 1 of 3
BUILDING DEPARTMENT COMMENTS:
A1. Partial or full permitting must be granted prior work commencing on the site for grading, excavation
and shoring. Partial permit may be granted with the agreement of all departments on the conditions
that remain from the original full building permit reviews.
A2. All agreements with neighboring effected property owners must be complete prior to issuance of
permit to begin Grading, Excavation and Shoring.
Shorinq Structural Comments:
1. Both "temporary" and "permanent" shoring systems are included in this submitted package. Please
veirfy appropriate measures for corrosion protection have been taken into consideration for the
permanent system, as appropriate for this project (i.e. dual corrosion protection @ unbonded ends,
encapsulated anchorage zones, anchor centering devices for grouted ends, corrosion of shotcrete
reinforcement & headed studs, etc.). Consider consistently labeling the the lagging and tieback
details with "permanent" or"temporary" throughout the set. Please verify that "structural shotcrete"
as noted on Sheet 1 refers to "permanent" shotcrete lagging.
2. Note D.2: current code required by IBC 2003 for this project is ACI 381-02; verify all ACI 2002
requirements are satisfied by these designs.
3. Please verify that specifications requirements, 02260, etc. have been satisfied (monitoring system,
dewatering, etc.). We strongly recommend that the design team review this submittal and ensure
coordination between the completed structure and temporary shoring system, please verify this is
being done. We have not done a coordination review as part of the permitting process. Verify
intended movements of the permanent shoring systems have been coordinated into the completed
structural deisgns, such that deflection compensation measures can be undertaken for structures not
designed for soil lateral loading.
4. Verify requirements of the project soils report have been used to prepare the calculations and
construction drawings for this system. For example, soils report, page 24 shows ❑'=35 degrees,
while it appears a 60 degree slope stability angle has been used for soil nail stability designs, per
submitted shoring calculations. Please comment.
5. Verify IBC Chapter 18 requirements are satisfied by these designs; micropile calculations state
"FHWA" as the governing code. Verify tieback embedment length below bottom of excavation meets
the minimum embedment for the restrained condition for an embedded pile.
6. The soils report does not address loading criteria for soil nailed shoring or soldier pile shoring
systems. Please verify loading diagragm for the single and double tieback soilder pile shoring
systems, it is unclear how the lateral soil loads are considered to taper to zero at the bottom 0.2H of
excavation. Pfease comment.
7. Drawing 2 & calculations: verify soildier beam schedule for structural steel channel as Fy=50 ksi, and
that 50 ksi channels are intended and are practical for this work. Our experience is 36 ksi channels
are much more common.
8. Wood lagging calculations are not provided, verify wet-service and temperature allowable stress
factors have been considered. 10 ft. seems a long span for lagging. Consider deflection of lagging.
9. Calculations dated 12-28-05, page 4/42: Micropile design load is given as 71 kips. Existing footing is
7'-6" square, which for 5 ksf bearing (as stated was used for micropile designs on calcs sheet 2/42)
results in a working load of 281 kips. Please explain the large difference in these numbers. Please
verify all designs.
C:\Documents and Settings\mroyer�Ivty Documents\Plan Review\Front Door\tov-b06-0018.Shoring.DOC Page 2 of 3
10. Caiculations dated 2-17-06, page 36/50: verify permanent factor of safety of 1.31 for this design;
seems 1.5 factor of safety is required per IBC Chapter 18, as for a permanent retaining wall. Typical
all soil nail walls.
11. Section 9/3 should be corrected to 8/3, please confirm.
Please refer to the cover sheet for information and instructions for resubmitting plans. The recheck of plans
usually occurs within 3-5 working days of plan re-submittal. In order to avoid delays please check all requested
information is included with the resubmitted plans.
Contact Person:
Matthew Royer
Building Official/Project Manager
Colorado Inspection Agency
970-328-1790
matt.rover(�coinspect.com
Plans Examiners and Enqineers:
James P. Horne, P.E., S.E.—Structural Review Project Manager
C:�Documents and Settings\mroyer�Ivly Documents�Plan Review\Front Door\tov-b06-0018.Shoring.DOC Page 3 of 3
' FW: B06-0018 - Shoring Plan Review Comments Responses Page 2 of 2
Matt,
Please find attached responses to the Shoring Plan Review Comments.
Let me know if any additional information is required.
Thanks
«Shoring Review Comments Response 5.23.06.doc»
«Schnabel Response to Shoring Comments.pdf»
Doug T'hompson
Hyder Construction Inc
Project Executive
Direct No.(720)932-3264
Cell No. (303)829-5950
Fax No. (303)825-3223
Main Office No.(303)825-1313
J Picture(Metafile)
i �
5/26/2006
C°t�:��;`��I1���C"'�"I():`�� I:�C'.
May 23, 2006
Mr. Matthew Royer
Building OfficiaUProject Manager
Colorado Inspection Agency
matt.royer@coinspect.com
RE: Vail's Front Door
Plan Review Comments B-06-0018-Shoring Only dated,5/17/06
Dear Matt,
In response to the Building Department Comments referenced above,I have attached the
responses from Schnabel Foundation Company which appear to address all of the comments
listed with the exception of item portions of item No. 3. The Specification Section referenced,
02260 Excavation Support and Excavation as well as Section 02832 Soil Nail Walls are part of
the Contract Documents. Hyder Construction and its subcontractors,as may be applicable, are
required to comply with the contract documents in their entirety. Monitoring of the site and
structures adjacent to or effected by the shoring are requirements in the specifications and thus is
to be implemented and maintained during the installation of the shoring and after until such time
as the building foundations are installed and backfilling of the structures is completed.
The site has had extensive testing and analysis performed for both the surface and ground water
conditions. A complete dewatering program has been designed and included in the scope of the
work. Permits with the State of Colorado for both the containment of sediments from surface
runoff and ground water discharge from excavation have been applied for, issued and copies of
the same have been provided to the Town of Vail. Dewatering specifically as it relates to
shoring has been considered in the design of the systems.
Additionally, although not called for in the Project Specifications, Hyder has submitted to the
project design team both progressive and final shoring design and calculations for coordination
with the buildings' foundations,the site grading and utilities.
From the nature of the comments it does not appear necessary to provide revised Shoring
drawings to be submitted to the Town. Please let me know if any further information is required
with regards to the Shoring Plan Review Comments.
S incerely,
Doug Thompson
Project Executive
cc: Mr. Charlie Davis, Chief Building Official,Town of Vail
Mr. Randy Hart,42/40 Architecture
Mr. Richard Caudel,Vail Resorts Development Co.
^ 05:'l,l,'U6 10:48 Fr��_a0a 7-15 0897 SGIIIADLL rUUNUATIO� C0. �;00�
� �l
�oL�.�.�o�v co�rn����
Nlr. Doug Thompso� Date: May 19, 2d06
Nyder Constructivn, Inc.
543 Sant� Fe Drive
Denv°r. CO. 8020�F
Doug,
Befow are our responses to the shoring structural commen�.s. The original comments ar� presented alang
with our responses in bo(d print.
1. E3oth "ternporary"�nd "permanent"shoring systems ar� included in this submitted package. Please
veirfy appropriate measures for corrosion protectivn have been taken into con�ider�tion for the
permanent system, as appropriat�for this project(i.e. dual corrosian prot�:ction @ unbonded ends,
encapsulated anchorage zones, 3nchor centering devices for grouted encis, corrosion of shotcrEte
reinfarcement&, headed stucts, etc.). Cansider consisten#ly labeling the ihE lac�ging and tieback details
with "perrnanenY' ar"temporary"fhroughout the set. Please verify that"st�uctura!shotcr�te" as noted
an Sheet 1 refers to"p�rmanent"shotcrete lagging.
All permanent anchors,whether'strand or bar, conform to Ciass 1 or 1( corrosion protection
guidelines for permanent ancF�ors in non-aggressive soits per Recommendations for
Prestressed Rock 8nd Soil Anchors; Post-tensioning Institute; PTI;2004. Corrosion protection
of headed studs is according to ACI 318-42.
There is no "shotcrete lagging" on the project. Thc laggine�wilt be as noted on Sheet 1 F.7; all
of the sold�er beam and lagging work is temporary.Tlie structurat shotcrete note (ShQefi 1 D)
perEains to the shotcrete facing on the non-soldier beam and lagging walis (both temporary
and permanent).
2. Note D.2: current code required by IBC 2003 for tt�is project is ACI 381-02; verify �11 ACl ?_002
requirements are satisfied by th�se designs.
ACI 318-02 rcquirements are satisfted in the designs per 1BC 2003. The suggestion of the use
of the 't995 ACl code is a drafiing error that was not cauc�ht in the drawing ►eview process.
The ACI 318-02 requirernents were followed in the design.
3. Please verify that specifications requirem�nts, 02260, etc. have been satisfied (monitoring system,
dewatering, etc.). We strongly recommend that the des�yn team review this submittal and ensure
coordin�tion betweon the completed structure and temporary shoring system, please verity this is
being done. We have not done a coordination review as part of the permi�ing process. Verify
intended movements of the permanent shoring systems have been coordinated into the com�leted
structural d�signs, such that deflection compen�atian measures can be undertaken for structures not
designed for soil l�teral loading.
05i19lo6 10:=19 F:�11 7U� i-1:i a9s7 SC:Ii\:1BEL .Ft)L'�UATIOV C0. f�jt�0�
Respanse by "others". Specification sections pertaining to shoring, sections 022G0, Q2300
and 02832,will be fo{lowed to the ext�nt required by our subcontract agreemenE with Hyder
Construction, Inc. it is unders�ood that Schnabel Foundation Campany is the `�engineer" and a
sub-c�ntractor for the shoring and soi! nailing work.
4, Verify requirements of the project soils re�ort hav� been used to prepare the calculations and
construction drawings for this system. For example, soils r�po�i, page 24 shows ❑'=35 degrees,
while it �ppears a 60 degree slope stability angle has been used for soil nail stabi(ity desic�ns, pe�
submitted shoring calculations. l'lease comment.
The �GO d�gre�failure angle is calculated as the angle with the towest factor of safety by�he
CaITRANS design pragram SNAILZ. Phi (c�= 35°) is a soi) property used in that catculation.
The recommendations of the project soils reports were utilized in the desi9n of a!I aspects of
tiie shoring for this project.
5. Verify IBC Chapter 1�3 requiremenfs are satisfied by these designs; micropile calculations state
"FHWA" as the govcrning code. Verify tieback embedment tength below battorn ot excavation meets
the minimum embedment for the restrained condition for an embedded pile.
Th� micropiles were deslgned to satisfy the requirements of current FHWA code; however, a
reanatysis af the design for IBC 2006 Chapter't8 carnptianc� verifies thatthe design as shown
complies whoNy with the lBC 2D06 code.
6. The �oils report does not address loading ctiteria for soil n�iled shoring or soldier pil� shoring
systems. PleasE v�rify loading diagrarn far the single and dauble tieback soldier pile shoring
Syst�ms, it is unclear f�ow the lateral soi! Icrids ara cortsidered to tapEr t�zero at the bottom 0.21-) of
excavation_ Ple�se commenk.
The earth pressure (laading) diagram used In the analysis is a modification of the 1948
recammendations made by Terzaghi and PecEc (Terzaghi, K. and R.B. Peck: Soil Mechanics in
Engineering Practice, John Wiley, New York, "1948; also refer to FHdtiIA Geotecttnical
Engineering C�rcular No.4 {FHWA-tF-99-015}),The modificatians to the loading diagram are
based on collected data and performance monitvring of soldier beam shoring projects in
similar soils that Schnabel Foundation Company tt�s built over the last 45 years {Schnabel, H.
Jr.; Tiebacks in Foundation Engineering and Construction, McGraw-Hill, 1982)_ Specifically
Schna�el Foundation Company has design/built numerous soldier 6eam and lagging shoring
systems in the Vail area (6�rrabelle, Vail Plaza Hotel,Vail Gateway Bui(ding, P3E�J,Vail Va!!ey
Medlcal Center,Vail Valtsy Parking Structure} and has encountered no circumstances which
would indicate ti�at this loading diagrarn is unconservative.The loadin� diagram utilized for
the one-t(er tiehack system is shown on A7I50 of the 2f17106 design submittal.
7. Drawing 2 3� calculations� verify soldier beam schedule for structural steel channe( as Fy=50 ksi, and
that 50 ksi chatinels are intended a�d are practical for this work. Our experience is 3G ksi channels
are much more common.
Tt�e steel for the channel secti4ns is A36.ThaL is misrepresented on fihe drawings,
II. Wood lagging c�(culations are not provided, vcrify w�t-service and tern�eralure allowable stress
factors have been consid�red. 10 ft. seems � long sp�n for fagging. Consider deflection oF lagging_
The wood lagging was si�:ed basnd on our experie�ce in similar sail conditions. In the site
sails,where considerable arching bef.ween soldier beams is achieved, 3-inch lagc�ing has
2
o;%la%06 i0:�s F:�� �o� 7�15 0957 __SCx�r�DEL FOL'�D:�T'Iq� C0. auo��
preformed well for cuts greater than 50' in depth {tt�e deepest soldier beam and tagging cut an
this project is less ti�an 25'}. Severat literature saurces confirm these obsenrations:
Guide{ines for �nqinee�inq Practice for Braced and Tied-back Excavatians; ASCE
Geotechnical Speciat Pubtication No. 74; 1997; pg. 76 "Because of the well-known effect of
arching earth pressures away from the midpoint of the lagging tv the more resistant soldier
pil�s,the de5ign of lagging to withstand uniformly distribufied eartF� pressures usually is
unrea{istic. Lagging thickness is selected on the basis of emplrical rules and experience
which depends on the character of the tetained soilsT spacing of soldier pites and depth of the
excavatio�. tn ordinary circumstances with usuat soldier beam spacings, 3 inch (�5mm} rougl�
v+rood laggi�g is used down to ciepths of 15 ta 30 feet..."
Construction Handbook far B�id �and Tem ara Works; A�SHTO; 1998; pp.62 presents a
tahle giving recommended laggittg thicknesses and is attacF�ed to this response tetter.
Handboak of Temporary St�uctures in Construction; R.T. Ratay; McGraw-Hill, 2"d Ed.; 1996; pg
8.30-8.31.
It should be noted that the method Schnabel Foundatian Company plans to use to install the
soldier 6eams is a drilled slurry rnethod. In this technique the soltlier beams are set into a 30"
diameter 1 sack mix slut'ry hole.This raduces the clear span between beams to a maximum of
7'-6".
Lagging deflection is considered in the installatioe�toleranc� provided to the general
contractor.
9. Calcul�tions dated 12-28-05, page 4/42: Micropile design load is given 3s 71 kips. Existing footing is
7'-6"squarc, which for 5 ksf bearing (as stated was used for micropile designs on calcs sheet 2/42)
resutts in a working load of 281 ki�s. Pl�ase explain the large difter�nce in these numb�rs. Please
verify all designs.
At the top of page �142 it states that there are 4 micropilcs on the 7'-6"x 7'-6" footing (Za1.25 ,
kips /4 micropiles =70.313 kips/micropile}. It is tf�e sarrte situation as sheets 3-6.
10. Calculations dated 2-17-06, page 36l50: verify perman�nt factor�f safety of 1.31 far this design;
seems 1.5 factor of safety is required per IBC Chapt�r 18, as for a permanent retaining wall. Typical
all soil nail walls.
The SNAILZ cDesign calculations originally provided are sufficient for the temporary soil
nailing east of Building D and the permanent sall nailing along the south tunnel wall. IBC
Ghapter 18 ('[8U6.1 Qg. 357} requires a factor ofi safety of 9.5 again�t overtutning of retaining
walls (not applicable for soii nail walls) and sliding of retain(ng watls (not applicabte for soil
nail walls). A higher factor of safety(F_S. = 1.5)was utilized for the large south and west side
permanent wafl work (elevations C and D} based on tha ertgineers judgment, However, a
factor of safety of 1.3 for the questi�ned design/work is considered sufficient at thase
locations_
11. Section 9/3 shoufd be corrected la 8J3, please confirm.
Yes, that is an error.
3
o:>;].9i9G 1Q:#�J F:il :)03 7�l� U98i SCIII:IDEL F()L\?U?�TIQti Cu. '�1U05
Please feel ir�e to contact me with any quesUons.
Sincerely,
��%`�^�-�'L Y%�
Christi�n H. Baxter, E.I.T.
Construction Manager
Schnabel f=oundation Company
2�50 S. Jamaica Ct. Suite 107
Aurora, CO. 80014
(c) (303) 517-6517
(o) {303}696-7268
(� tso3> 7�.�-osa�
cbaxtEr daschnabel.com
n
� � � � o � �
TRANSMITTAL LETTER
VAIL RESORTS DEVELOPMENT COMPANY
(970)845-2382 Telephone MAY 31 Z006
(970845-2555 Fax#
PROJECT(S): VaiPs Front Door PROJECT NO. ZJ156 T(�
REFERENCE NO: 007
DATE: May 31,2006
TO: Town of Vail Community Development IF ENCLOSURES ARE NOT AS NOTED,
PLEASE INFORM US IMMEDIATELY.
ATTN: Charlie Davis
Chief Building Official IF CHECKED BELOW,PLEASE:
(x) ACKNOWLEDGE RECEIPT OF ENCLOSURES
( )RETURN ENCLOSURES TO US.
WE TRANSMIT:
(x) HEREWITH O IN ACCORDANCE WITH YOUR REQUEST
( ) UNDER SEPARATE COVER VIA
FOR YOUR:
( ) APPROVAL (x)DISTRIBUTION TO PARTIES (x) INFORMATION
(X) REVIEW& COMMENT (x)RECORDS
(x) USE ( )
THE FOLLOWING:
O DRAWINGS O SHOP DRAWING PRINTS O PRODUCT INFO
O SPECIFICATIONS O SHOP DRAWING REPRODUCTIONS O SAMPLES
O CHANGE ORDER (x)_Signed Tie back agreements_
COPIES DATE REV.NO. DESCRIPTION ACTION CODE
2 5/30/06 N/A Signed Tie Back Agreements to LPI& SLT A
ACTION: A. ACTION INDICATED ON ITEM(S)TRANSMITTED
B. NO ACTION REQUIRED
C. FOR SIGNATLJRE AND RETURN TO THIS OFFICE
D. FOR SIGNATURE AND FORWARDING (as noted below,under"Remarks")
E. SEE"REMARKS" BELOW
REMARKS:
COPIES TO: WITH ENCLOSURE(S)
Master File (x) �
� )
BY: Rick audel, Sr. Project Manager
Vail Resorts Development Company
Design and Construction
� � I� [lMl�
. (,,�
Y 2006
CONSTRUCTION EASEMENT AGREEMENT
� `TO�/1/N OF VAIL
THIS CONSTRUCTION EASEMENT AGREEMENT (this "Agreement") is �
made as of the � day of /� , 2006, by and between Lodge Properties Inc., a
Colorado corporation ("Grantor"), d Lodge Properties Inc., a Colorado corporation, and The
Vail Corporation, d/b/a Vail Associates, Inc., a Colorado corporation(together the"Grantee").
RECITALS:
A. Grantor is the owner of that certain property known as the Lodge at Vail
(the"Hotel"), located in the Town of Vail, State of Colorado (the "Town"); the Hotel and its site
(the "5ervient Estate") are legally described on Exhibit A atta.ched hereto and incorporated
herein by this reference.
B. Grantee is the owner of certain real property contiguous or proximate to
the Servient Estate that is commonly known or referred to as part of"Vail's Front Door" and
that is legally described on Exhibit B attached hereto and incorporated herein by this reference
(the "Front Door Property"). Grantee intends to commence the development and construction
on the Front Door Property of a mixed-use real estate project that may include, without
limitation, residential townhomes/condominiums, a skier services building and facilities, a ski
club facility, a subterranean garage facility incorporating commercial loading and delivery
facilities for both public and private use, including multiple loading bays, ski yard
improvements, and other improvements and facilities ancillary, incidental or related to the
foregoing(collectively the"Front Door ProjecY').
C. In order to undertake construction of certain elements of the Front Door
Project, Grantee has requested that the Grantor grant an easement to install and use, within
subterranean portions of the Servient Estate, tieback anchors (the "Tiebacks") constituting part
of a construction shoring system that also incorporates soldier beams and related materials and
that is necessary to provide interim support for and to stabilize construction, excavation and
installation for certain elements of the Front Door Project and prevent subsidence of soils during
the course of construction(the "Shoring System"). The construction and installation process for
the Tiebacks is sometimes referred to hereinafter as the "Construction." Grantor has
determined to grant the requested easement in accordance with and subject to all the terms and
provisions of this Agreement.
NOW, THEREFORE, in consideration of the above premises, and the mutual
covenants and agreements set forth herein, Grantor and Grantee covenant and agree as follows:
1. Grant of Construction Easement.
(a) The Grantor hereby grants and conveys to Grantee an irrevocable,
temporary, non-exclusive construction easement beneath and under the surface of the
Servient Estate for the construction, installation, operation, testing, inspection,
maintenance, and use of the Tiebacks in conjunction with and throughout the course of
the construction, installation and development of the Front Door Project (the
J:\Chalets at the Lodge at VaillEasements\Tieback-LPI-FINAL.doc
"Easement"). The Easement shall cover an area within and under the surface of the
Servient Estate which, as deternuned by Grantee in the ordinary course of the
construction of the Front Door Project, is reasonably necessary or appropriate for the
Construction in accordance with the Plans (hereinafter defined), and otherwise for the use
and enjoyment of the Easement as contemplated herein and the performance of Grantee's
obligations and duties hereunder.
(b) The Easement shall become effective as of the date of the mutual
execution and delivery of this Agreement, and shall remain in full force and effect until
the completion of the construction of the Front Door Project, which for this purpose shall
be deemed to occur (i) only at such time as Grantee secures a temporary or permanent
certificate or certificates of occupancy issued by the Town which authorizes the ongoing
occupancy, use and enjoyment of the building improvements within the Front Door
Project developed by Grantee, or (ii) if and when Grantee at its election voluntarily
relinquishes its rights under the Easement by a recorded written instrument to that effect
executed by Grantee. The Easement may be used and enjoyed by Grantee and its agents,
employees, contractors, and designees (which may include any and all affiliates of
Grantee), and any other agents, contractors and invitees acting by, through or under any
of them (collectively with the Grantee, the "Permittees"). For purposes of this
Agreement, the "affiliates" of Grantee shall mean any corporation or entity which, by
virtue of direct or indirect majority ownership interests, is controlled by, controls, or is
under common control with either party comprising Grantee (and the applicable affiliates
shall be third-party beneficiaries of those provisions hereunder which refer to them).
2. Construction Process; Mechanic's Liens.
(a) Grantee covenants to the Grantor that the Tiebacks will be
constructed and installed in material conformity with the plans and specifications therefor
identified on Exhibit C attached hereto and incorporated herein by this reference (the
"Plans"). 'The Plans may be further modified as required by the Town or as determined
by Grantee, so long as any such modifications do not create any material conflict with the
other provisions set forth below. Grantee covenants that the Construction will be
undertaken in a good and workmanlike manner, in conformity with all applicable legal
construction requirements as applied and enforced by the Town, pursuant to customary
drilling construction methods for purposes of minimizing noise and vibration, and in
accordance with other good construction practices to avoid any penetration of or physical
damage to any building improvements presently located on or above the Servient Estate
(the "Servient Improvements"); that the Construction will not impair any subjacent or
lateral support for the surface of the Servient Estate or any Servient Improvements or
appurtenances thereto, as such support is necessary for the use and enjoyment thereof;
and that the Construction will not break, cut or impair the normal function of any utility
lines or facilities located on and serving the Servient Estate or Servient Improvements.
(b) Grantee will not cause or permit any mechanic's lien claims to be
made against any ownership interests in the Servient Estate that arise from the
Construction. If any such mechanic's lien claim is recorded against any such property
interests, then Grantee shall, within thirty (30) days after the recording of such lien claim,
J:\Chaleu at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 2
obtain the release of the affected property interests in the Servient Estate from such lien
claim, whether by discharge, bonding or otherwise (and so long as this discharge is
satisfied, the Grantee may contest any mechanic's lien claim in good faith). If Grantee
shall fail (i)to furnish the requisite release within the aforesaid 30-day period, then the
Grantor may, at its option, secure the release of the lien claim by any means available,
including bonding or settlement, in which case Grantee shall, witlun thirty (30) days after
notice of demand, reimburse Grantor for the latter's costs and expenses incurred in
securing the lien release, including reasonable attorneys' fees.
(c) Crrantee, at its sole cost and expense, shall institute, carry out, and
mainta.in measures and procedures in accordance with the following provisions, and that
are otherwise customary under prevailing standards in the construction industry, to
monitor any occurrence of differential movement of the structural foundation of the
Servient Improvements that is caused by the undertaking of the Construction and that
results in structural damage to the Servient Improvements (a "Material MovemenY'; the
pertinent structural damage resulting from a Material Movement is sometimes referred to
herein as "Construction Damage"). In furtherance of the foregoing:
(i) Grantee, in consultation with Grantor's Representative
(hereinafter defined), will conduct a physical survey inspection of the interior and
exterior of the Servient Improvements, with such survey to include "spot crack
mapping," in order to establish and document an informational base of the
existing condition of the Servient Improvements prior to the cornmencement of
the Construction. Grantor shall cause Grantor's Representative to cooperate
promptly and diligently with Grantee in furtherance of expediting this survey
inspection process and will join in such documentation as may be reasonably
necessary or appropriate for this purpose.
(ii) Grantee will install and maintain monument measuring
devices (the "Monument Devices") for purposes of detecting any Material
Movement. The Monument Devices shall be affixed to the Servient
Improvements at locations and in numbers adequate for this detection process, as
determined by Grantee in accordance with ordinary construction practices. Initial
readings of the Monument Devices will be taken prior to any Construction and/or
Excavation (as defined below) in order to augment the survey inspection and
establish the then existing condition of the Servient Improvements as reflected by
the Monument Devices. Grantee shall also engage a qualified surveyor or
engineer to install the Monument Devices, to take readings therefrom as set forth
below, and to otherwise consult and furnish customary services to Grantee for
monitoring and detecting any Material Movement. The readings from the
Monument Devices shall be taken (A) no less frequently than once a calendar
month at such time as Excavation has commenced, and thereafter until the date
six (6) months after the pertinent foundations of the Front Door Proj ect are
completed (as evidenced by the completion of backfill, including compaction
thereof, between the foundation and shoring), and (B)no less frequently than once
every six (6) calendar months thereafter until the Front Door Project is completed
(as evidenced by the Town's issuance of temporary or permanent certificates of
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 3
occupancy for the building improvements within the Front Door Project). Soldier
beams may be installed as part of the Shoring System on or before the
Construction of the Tiebacks commences, and perhaps several months in advance
thereof, and the installation of those soldier beams will not necessitate the
commencement of monitoring from the Monument Devices. "Excavation" shall
mean the undertaking of construction excavation for the Front Door Project
within the Front Door Properiy. Crrantee, in the ordinary course of construction,
will keep the Grantor's Representative promptly apprised of the results and data
from readings of the Monument Devices, and upon request of Grantor's
Representative from time to time, will otherwise consult reasonably with
Grantor's Representative on the status of the Construction activities in relation to
the provisions of this Agreement.
(iii) In the event any readings from the Monument Devices
detect any Material Movement, then Grantee shall immediately institute all
measures reasonably necessary to prevent any further Construction Damage that
may result from the ongoing Construction process, and shall also be obligated to
undertake any and all repairs necessary to remedy the Construction Damage
already caused. In that regard, the Grantee shall ha�e prepared and furnished to
Grantor's Representative proposed plans for any repairs and the proposed general
contractor to undertake the same,both of which will be subject to the prior written
approval of the Grantor (which shall not be unreasonably withheld or delayed).
Grantee shall be fully liable for any Construction Damage and the requisite
repairs therefor pursuant to Grantee's indemnity under paragraph 4 below.
(iv) Grantor shall designate one individual to act for Grantor
and represent the interests of Grantor in connection with this Agreement for
purposes of communicating and dealing with Grantee ("Grantor's
Representative"). Grantor shall designate Grantor's Representative by notice to
Grantee given within three (3)business days after the date of this Agreement.
Thereafter, Grantor at its election may change Grantor's Representative upon
further written notice to Grantee. In any case only one individual may serve as
Grantor's Representative at any time. Approvals given or other determinations
made by Grantor's Representative in the course of dealings with Grantee shall be
binding upon Grantor.
(v) Grantee will be afforded access to the surface of the
Servient Estate and the Servient Improvements as reasonably necessary or
appropriate in connection with the implementation of the monitoring and other
functions and provisions of this paragraph 2(c).
3. Non-Exclusive• Quiet Eniovment. The Easement shall be non-exclusive,
and the Grantor expressly reserves the right to the use, enjoyment and occupancy of the surface
of and all other portions of the Servient Estate for any and all purposes that are not inconsistent
with the terms of the Easement and the rights and interests afforded to Grantee under the terms
hereof. Grantor specifically agrees that none of them shall do or permit anything to be done
which physically disturbs or impairs the function of the Tiebacks during the course of the
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 4
Construction or the development of the Front Door Project, or which otherwise violates or
materially interferes with the use and enjoyment of the Easement by Grantee or the other
Permittees.
4. Indemni . To the fullest extent permitted by law, Grantee shall
indemnify and defend Grantor and its successors and assigns, and sha11 hold each of them
hazmless from and against (i) any physical damage to the property of such indemnified parties or
any personal injuries suffered by them (including Construction Damage to the Servient
Improvements), and(ii) any liabilities suffered or incurred by such indemnified parties as a result
of any personal injury or physical damage to property suffered by third parties, if caused by the
undertaking of the Construction, any negligence or willful misconduct of the Grantee occurring
in relation to the use and enjoyment of the Easement, or any breach of the Grantee's obligations
under this Agreement. This indemnity will also apply to and include costs and expenses,
including reasonable attorneys' fees, incurred by the indemnified parties in connection with any
indemnified matter. Notwithstanding any implications to the contrary in the foregoing
provisions, the foregoing shall not be construed to waive or limit any requirements imposed upon
the indemnified parties by law to mitigate their damages, and this indemnity shall not apply to
matters stemming from the negligence, willful misconduct or breach of this Agreement by the
Grantor.
5. Remedies• Attornevs' Fees.
(a) The rights of either party hereunder may be enforced by any
remedies available at law or equity, including, without limitation, the recovery of
damages, and where appropriate, injunctive or other equitable relief to prevent the
occurrence or continuance of any default hereunder, or to enforce the performance and
observance of the terms of this Agreement. All remedies shall be cumulative with and in
addition to, and not exclusive of, one another; any and all remedies may be pursued by
the non-defaulting party either successively or concurrently; and the exercise of any one
remedy shall not be construed as or constitute a bar to the exercise of any other remedy.
(b) In the event any legal proceeding arises out of this Agreement and
is prosecuted to final judgment, the prevailing party shall be entitled to recover from the
other party all of the prevailing party's costs and expenses incurred in connection
therewith, including reasonable attorneys' fees (and any presiding court will be bound to
make this award). Should the application of this provision in any circumstance prove to
conflict with any other proyision of this Agreement for the allocation of attorneys' fees,
this provision shall be controlling.
6. Successors in Interest; Assi�nment. The rights, interests and obligations
of the parties under this Agreement, including the Easement, shall touch and concern and run
with the land as a benefit and burden to the ownership of the Servient Estate. With respect to
Grantee, the Easement shall constitute an easement in gross in favor of Grantee, and the
Grantee's interests therein and under this Agreement shall not run to the benefit of any successor
owner of the Front Door Property, or any portion thereof, unless and until Grantee makes and
records an assignment of such interests in favor of such successor (and the Easement and this
Agreement will be freely assignable by Assignee to any successor in interest to the Front Door
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 5
Property or any portion thereo fl. Notwithstanding any such succession of ownership interests,
Grantee will remain liable for its obligations hereunder, except for any such obligations assumed
by its assignee by an instrument recorded in the real property records for Eagle County, Colorado
(an "Assuming Assignee"). No successor in interest of Grantee in and to the real property and
improvements thereon constituting the Front Door Property, or any portion thereof, will have any
obligation for any of the Grantee's obligations hereunder except as provided in the recorded
assumption made by that successor as an Assuming Assignee, if applicable. In the case of any
assignment, the term "Grantee" shall from time to time mean the assignee then holding
Grantee's rights hereunder.
7. Authori . Grantee hereby represents to Grantor that Grantee has taken or
received all corporate action or authorization necessary for Grantee to enter into this Agreement;
that Grantee's entry into this Agreement constitutes the duly authorized corporate action of
Grantee; and that this Agreement is binding on Grantee. Grantor in turn represents to Grantee
that Grantor has taken or received all corporate action or authorization necessary for Grantor to
enter into this Agreement; that Grantor's entry into this Agreement constitutes the duly
authorized corporate action of the Grantor; and that this Agreement is binding on the Grantor.
8. Com�letion of Construction. Upon the completion of the construction of
the Front Door Project, as such completion is defined in paragraph 1(b) above, the Easement
shall terminate, Grantor shall hold the Servient Estate free from the Easement, and Grantee will
have no further right to the use and enjoyment of the Easement or Tiebacks and shall be deemed
to have abandoned the same. Upon such termination of the Easement, it is understood that the
Tiebacks will be abandoned in place on the Servient Estate, and Grantee shall have no obligation
or duty to remove the same. Upon such abandonment, Grantor, in turn and at its election and
without obligation to Grantee, may leave the Tiebacks in place or otherwise manage, treat or
dispose of the Tiebacks in any manner permitted by law, and Grantee will have no further
obligation in connection with the Tiebacks commencing from and after such abandonment.
Upon the termination of the Easement due to completion of construction or otherwise, either
party, upon the request of the other, shall execute and deliver a recordable instrument confirming
that such termination has occurred, and that the parties are released from any further obligations
and duties hereunder. Notwithstanding any transfer of the Front Door Property or any portion
thereof, the Grantee named herein will retain the right and power to effectuate such confirmation
of ternunation unless such right and power are expressly assigned of record.
9. Severabilitv. If any term, covenant, condition or provision of this
Agreement shall, at any time or to any extent, be invalid or unenforceable, the remainder of this
Agreement shall not be affected thereby, it being the intent of the parties that this Agreement and
each provision hereof shall be enforceable and enforced to the fullest extent permitted by law.
10. Entire A�reement. This Agreement and any other contracts or agreements
specifically referred to herein represent the entire agreement between the parties hereto with
respect to the subject matter hereof, and all prior or extrinsic agreements, understandings or
negotiations shall be deemed merged herein. All Exhibits referred to in this Agreement as
attached hereto are hereby deemed incorporated into this Agreement and made a part hereof.
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 6
11. Rules of Construction. The headings which appear in this Agreement are
for purposes of convenience and reference and are not in any sense to be construed as modifying
the paragraphs in which they appear. References herein to the singular shall include the plural,
and to the plural shall include the singular, and any reference to any one gender shall be deemed
to include and be applicable to all genders.
12. Governin� Law. This Agreement shall be governed by and construed in
accordance with the laws of the State of Colorado.
13. Modification and Waiver. No purported modification of the terms of this
Agreement, or purported waiver by any party of any of its rights and interests hereunder, shall be
binding unless and except to the extent specifically set forth in a written instru.ment executed by
the party against whom enforcement of the purported modification or waiver is sought.
14. Counter�arts. This Agreement may be executed in counterparts, each of
which shall be deemed an original, and all of which together shall constitute one and the same
instrument and agreement.
15. Notices; Business Davs. Any notice required or permitted under the terms
of this Agreement shall be in writing, may be given by the parties hereto or such parties'
respective legal counsel, and shall be deemed given and received (i) when hand delivered to the
intended recipient, by whatever means; (ii)three (3)business days after the same is deposited in
the United States mails, with adequate postage prepaid, and sent by registered or certified mail,
with return receipt requested; (iii) one (1)business day after the same is deposited with an
overnight courier service of national or international reputation having a delivery area
encompassing the address of the intended recipient, with the delivery charges prepaid; or
(iv)when received via facsimile on the intended recipient's facsimile facilities accessed by the
applicable telephone number set forth below (provided such facsimile delivery and receipt is
confirmed on the facsimile facilities of the noticing party). Any notice under clause (i), (ii) or
(iii) above shall be delivered or mailed, as the case may be, to the appropriate address set forth
below.
If to Grantee:
Lodge Properties Inc. and Vail Associates, Inc.
c/o Vail Resorts Development Company
Post Office Box 959
137 Benchmark Road
Avon, Colorado 81620
Attention: Jack Hunn, Senior Vice President
Fax No.: (970) 845-2555
Phone: (970) 845-2359
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 7
With a copy to:
Lodge Properties Inc. and Vail Associates, Inc.
c/o Vail Resorts Development Company
Legal Department
Post Office Box 959
137 Benchmark Road
Avon, Colorado 81620
Attention: Julie A. Stencel, Esq.
Fax No.: (970) 845-2555
Phone: (970} 845-2548
If to Grantor:
Lodge Properties Inc.
174 E. Gore Creek Drive
Vail, Colorado 81657
Attention: Wolfgang Triebnig
F�No.: (970)477-3743
Phone: (970) 477-3737
Either party may change its addresses and/or fa�c numbers for notices pursuant to a written notice
which is given in accordance with the terms hereof. Any notice may be given on behalf of a
party by its legal counsel. As used herein, the term "business day" sha11 mean any day other
than a Saturday, a Sunday, or a legal holiday for which U.S. mail service is not provided.
Whenever any date or the expiration of any period specified under this Agreement falls on a day
other than a business day, then such date or period shall be deemed extended to the next
succeeding business day thereafter.
16. Recordin�. This Agreement may be recorded in the Records at the
election and expense of Grantee.
17. No Mer�er of Interests. Notwithstanding that Lodge Properties Inc.
presently holds both the fee ownership interests in the Servient Estate and an ownership interest
in the Easement, and notwithstanding any other commonality of interests subsequently arising
when any one party holds interests in both the fee ownership of the Servient Estate and the
Easement, any such commonality of interests shall not give rise to any merger of the Easement
or any other provisions hereof with the fee ownership of the Servient Estate, or any
extinguishment of the Easement or any such provisions, it being the mutual controlling and
dominant intent of both The Vail Corporation, d/b/a Vail Associates, Inc. and Lodge Properties
Inc., in its capacity as both the owner of the Servient Estate and as one of the parties comprising
Grantee, that no such merger or extinguishment shall occur, and that the Easement and other
provisions of this Agreement shall remain in full force and effect regardless of any such
commonality of interests, and without any limitation or impairment arising by virtue of such
commonality of interests.
(Balance of page intentionally left blank]
J:\Chalets at the L.odge at Vail�Easements\Tieback-LPI-FINAL.doc g
IN WITNESS WHEREOF, Grantor and Grantee have made this Construction
Easement Agreement as of the day, month and year first above written.
GRANTOR:
Lodge Properties Inc., a Colorado corporation
By:
Name: �. m
Title:
STATE OF GO LO�'� )
) ss:
COUNTY OF (�i,,AG t„�.. )
The foregoing instrument was acknowledged before me this � day of
, 2006, by t�,�'�t� ��G wJ �t�-tr�t as �.lP
of Lodge P perties, Inc., a Colorado corporation.
Witness my hand and official seal.
My commission expires: . �1 ��2t�c�8 Q►:.L�RO
•pSAq ••
•• }•
.�. :
: •
.
Notary Public : '
.
o •
a •
. •
��'''�VBL�G'��
[Signature blocks of Grantee follow on next page] '��'F•••••••••pPP
�F COL
My Commissior►Expires 0711912008
::���,,�:,�;, ,,,,,, ,,,,,
1�� "` :•/:!'� sS
� UG
�at!i• _�-�.J�_.� .. ......." =`_�
9�c': ..__ �...C�`�— ��
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 9
GR.ANTEE:
Lodge Properties Inc., a Colorado corporation
By
Name: �� � (Z6►1
Title:
STATE OF COLORADO )
) ss:
COUNTY OF C�G 1L )
The foregoing inst.�ument was acknowledged before me this _� day of
, 2006, by �� �. 2.C�t m as �!'�
of Lodge roperties Inc., a Colorado corporation.
Witness my hand and official seal.
��LO�qO
My commission expires: .�t �i�200� �.•�O'�AIQ�::
.
.
a
Notary Public : =
�A9j�.`BL`G�POo
••......
[Signature blocks of Grantee continue on next page] �F C���
My Corrums�on E�hes o7/1sJ2o06
:;�flir��;s•;.i ... . . � ..,
�''di7 Kc�:���. 7 ,p :: /
- �' --�- -.G/ `"
i„n2�:: -,. ._. 'j; -
€);.c: � L G- O C____
J:\Chaleu at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 1�
GRANTEE:
The Vail Corporation, d/b/a Vail Associates,
Inc., a Colorado corporation
By•
Name: Q.
Title:
STATE OF COLORADO )
) ss:
COUNTY OF �G�� )
The foregoing instrument was acknowledged before me this � day of
, 2006, by I�rv�#i �J G�4� P�S �YP
of The V. 1 Corporation, dlb/a Vail Associates, Inc., a Colorado corporation.
Witness my hand and official sea.l. �u��3���
ao����o
My commission expires: . �( � �Zb�� ''�����''
C���7�1 e�o%;�,t,
.
.
. �
LO Notary Public � ;
�PO.TA�9���. ��1db10�.:
:� �' • ••..
. •
• ' ��0� '�d
. .
. •
. •
o •
o •
•
�'Ay��V B I.�G'p,00
FO•....•••
F CO�-��
My Commission Expi�es 07119I2008
:itt�tr��z t�..;.,.: . . ... ,.
\.'1i�+�"` ... . ....'citlPt:t
.. � . . .._ ._.
�
�nlf:C: ./'-�i. _ .. .. -- -� _-'_
6��: S- ly '�.�s .___
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc 1 1
EXHIBIT A
Legal Description of
Servient Estate
LOT l,
LODGE SUBDIVISION, VAIL VILLAGE FIRST FILING,
ACCORDING TO THE PLAT THEREOF
RECORDED MARCH 30, 2004, AT RECEPTION NO. 872294,
COUNTY OF EAGLE,
STATE OF COLORADO
J:\Chalets at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc !�-1
EXHIBIT B
Legal Description of
the Front Door Property
PARCEL 1
LOTS 1 AND 2,
MILL CREEK SUBDIVISION,
ACCORDING TO THE PLAT THEREOF
RECORDED NOVEMBER 6, 2000, AT RECEPTION NO. 743366,
COUNTY OF EAGLE,
STATE OF COLORADO
PARCEL 2
LOTS 1 AND 4,
SECTION 8, TOWNSHIP 5 SOUTH, RANGE 80 WEST
OF THE SIXTH PRINCIPAL MERIDIAN,
COUNTY OF EAGLE, STATE OF COLORADO,
AS CONVEYED TO THE VAIL CORPORATION
BY IJNITED STATES PATENT RECORDED APRIL 26, 2006,
AT RECEPTION NO. 200610676,
AND ALTERNATIVELY DESCRIBED AS:
LOTS 1 AND 4,
SECTION 8, TOWNSHIP 5 SOUTH, RANGE 80 WEST,
OF THE SIXTH PRINCIPAL MERIDIAN,
COUNTY OF EAGLE, STATE OF COLORADO,
AS ESTABLISHED BY THE DEPENDENT RESURVEYS AND SURVEYS
COMPLETED BY THE UNITED STATES DEPARTMENT OF THE INTERIOR,
BUREAU OF LAND MANAGEMENT, DATED FEBRUARY 3, 2005 (LOT 4),
AND DECEMBER 30, 1988 (LOT 1)
J:\Chalets at the Lodge at Vail�Easemenu\Tieback-LPI-FINAL.doc B-1
EXHIBIT C
Plans
(see the attached)
J:\ChalcE9 at the Lodge at Vail�Easements\Tieback-LPI-FINAL.doc C-1
_ ���
. ��
Py
CONSTRUCTION EASEMENT AGREEMENT
THIS CONSTRUCTION EASEMENT AGREEMENT ("AgreemenY') is made effective as of
the 30�day of May, 2006 (the "Effective Date"), by and beiween Lodge South Condominium
Association, Inc., a Colorado corporation d/b/a Lodge Tower Condominium Association, Inc.
("Grantor"), and Vail Resorts Development Company, a Colorado corporation ("Grantee").
RECITALS:
A. Grantor is the governing owners association for the Lodge Tower Condominiums
(the "Condominiums") located in the Town of Vail, State of Colorado (the "Town"), which
Condominiums were established by that certain condominium map recorded in the real property
records for Eagle County, Colorado (the "Records"), on October 23, 1973 at Reception Number
127488 and Declaration of Grants, Submissions, and Covenants Governing Condominium
Ownership of the Lodge South Condominium recorded October 23, 1973 in Book 231 at Page
612 of the Records as amended by that certain First Amendment to Declaration of Grants,
Submissions, and Covenants Governing Condominium Ownership of the Lodge South
Condominium recorded July 14, 2004 at Reception No. 884003 of the Records. The real property
which is included within that condominium map and condominium declazation is sometimes
referred to hereinafter as the "Servient Estate." Grantor is making this Agreement on its own
behalf and on behalf of its constituent members (the "Members"), collectively and singularly,
which Members are the owners of units within the Condominiums.
B. Gran,tee's affiliate, Lodge Properties, Inc. ("LPI") is the owner of certain real
property contiguous or proximate to the Servient Estate that is commonly known or referred to as
part of "Vail's Front Door" and that is legally described on Exhibit A attached hereto and
incorporated herein by this reference (the "Front Door Property"). Grantee through LPI
intends to commence the development and construction on the Front Door Property of a mixed-
use real estate project that may include, without limitation, residential town
homes/condominiums, a skier services building and facilities, a ski club facility, a subterranean
garage facility incorporating commercial loading and delivery facilities for both public and
private use, multiple loading bays, ski yard improvements, and other improvements and facilities
ancillary, incidental or related to the foregoing (collectively the"Front Door Project").
C. In order to undertake construction of certain elements of the Front Door Project,
Grantee has requested that Grantor grant an easement to install and use, within subterranean
portions of the Servient Estate, tieback anchors (the "Tiebacks") constituting part of a
construction shoring system that also incorporates soldier beams and related materials and that is
necessary to provide interim support for and to stabilize construction, excavation and installation
for the building improvements of the Front Door Project abutting the property line between the
Front Door Property and the Condominiums (the "Abutting Improvements") and prevent
subsidence of soils during the course of construction (the "Shoring System"). The construction
and installation process for the Tiebacks is sometimes referred to hereinafter as the
"Construction." Grantor has determined to grant the requested easement in accordance with
and subject to all the terms and provisions of this Agreement.
J:\Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
NOW, THEREFORE, in consideration of the above premises, and the mutual covenants
and agreements set forth herein, Grantor and Grantee covenant and agree as follows:
1. Grant of Construction Easement.
(a) Grantor, on its own behalf and on behalf of its Members, hereby grants
and conveys to Grantee an irrevocable, temporary, non-exclusive construction easement beneath
and under the surface of the Servient Estate for the construction, installation, operation, testing,
inspection, maintenance, and use of the Tiebacks in conjunction with and throughout the course
of the construction, installation and development of the Abutting Improvements as further
provided and limited herein (the "Easement"). The Easement sha11 cover an area under the
surface of the Servient Estate that, as determined by Grantee in the ordinary course of the
construction of the Front Door Project, is reasonably necessary or appropriate for the
Construction in accordance with the Plans (hereinafter defined).
(b) The Easement shall become effective as of the date of the Effective Date,
and shall remain in full force and effect until the first to occur of (i) the completion of the
construction of the Abutting Improvements, which for this purpose shall be deemed to be at such
time as Grantee secures a temporary or permanent certificate or certificates of occupancy issued
by the Town that authorize the ongoing occupancy, use and enjoyment of the Abutting
Improvements, or (ii) if and when Grantee at its election voluntarily relinquishes its rights under
the Easement by a recorded written instnunent to that effect executed by Grantee, or (iii) 36
months after the Effective Date. The Easement may be used and enjoyed by Grantee and its
agents, employees, contractors, and designees (which may include any and all affiliates of
Grantee), and any other agents, contractors and invitees acting by, through or under any of them
(collectively with Grantee, the "Permittees"). For purposes of this Agreement, the "affiliates"
of Grantee shall mean any corporation or entity which, by virtue of direct or indirect majority
ownership interests, is controlled by, controls, or is under common control with Grantee.
2. Construction Process; Mechanic's Liens.
(a) Grantee covenants to Grantor that the Shoring System and the Tiebacks
will be constructed and installed in material conformity with the plans and specifications therefor
identified on Exhibit B attached hereto and incorporated herein by this reference (the "Plans").
The Plans may be further modified as required by the Town or as determined by Grantee, so long
as any such modifications do not create any material conflict with the other provisions set forth
below, and upon Grantor's written approval of all Plan modifications that affect shoring under
Grantor's building. Grantee will provide Grantor with all proposed Plan modifications, and
Grantor shall have seven (7) business days to review and object to any such modifications that
may, in its reasonable judgment, affect the foundation of the Condominiums. Failure to make a
reasonable objection to any Plan modifications within that time period will be deemed as
Grantor's approval. Grantee shall not proceed to carry out any work constituting Plan
modifications that is not approved or deemed approved by Grantor. Grantee covenants that the
Construction will be tuldertaken in a good and workmanlike manner, in conformity with all
applicable legal construction requirements as applied and enforced by the Town, pursuant to
customary drilling construction methods for purposes of minimizing noise and vibration, and in
2
J:\Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
accordance with other good construction practices to avoid any penetration of or physical
damage to any building improvements presently located on the Servient Estate (the "Servient
Improvements"); that the Construction will not impair any subjacent or lateral support for the
surface of the Servient Estate or any Servient Improvements or appurtenances thereto, as such
support is necessary for the use and enjoyment thereof; and that the Construction will not break,
cut or unpair the normal function of any utility lines or facilities located on and serving the
Servient Estate.
(b) Grantee will not cause or permit any mechanic's lien claims to be made
against any ownership interests in the Servient Estate that arise from the Construction. If any
such mechanic's lien claim is recorded against any such property interests, then Grantee shall,
within ten (10) days after the recording of such lien claim, obtain the release of the affected
property interests in the Servient Estate from such lien claim, whether by discharge, bonding or
otherwise (and so long as this discharge is satisfied, Grantee may contest any mechanic's lien
claim in good faith). If Grantee shall fail (i)to furnish the requisite release or security within the
aforesaid 10-day period, then Grantor may, at its option, secure the release of the lien claim by
any means available, including bonding, settlement or resort to any security furnished by
Grantee, in which case Grantee shall, within ten (10) days after notice of demand, reimburse
Grantor for the latter's costs and expenses incurred in securing the lien release, including
reasonable attorneys' fees and bond premiums (except to the extent recouped from any such
security). Grantee acknowledges and agrees that Grantor may, but shall not be required to, post
or serve a notice that Grantor's interest in the Servient Estate shall not be subject to any
mechanics' liens pursuant to the provisions of C.R.S. § 38-22-105, and to take such other actions
as Grantor deems necessary to comply with the provisions of said statute.
(c) Grantee, at its sole cost and expense, shall institute, carry out, and
maintain measures and procedures in accordance with the following provisions, and that are
otherwise customary under prevailing standards in the construction industry, to monitor any
occurrence of differential movement of the structural foundation of the Servient Improvements
that is caused by the undertaking of the Construction and that results in structural damage to the
Servient Improvements (a"Material Movement"; the pertinent structural damage resulting from
a Material Movement is sometimes referred to herein as "Construction Damage"). In
furtherance of the foregoing:
(i) Grantee, in consultation with Grantor's Representative as defined
below, will conduct a physical survey inspection of the interior and exterior of the
Servient Improvements, with such survey to include "spot crack mapping," in order to
establish and document an informational base of the existing condition of the Servient
Improvements prior to the commencement of the Construction. Grantor shall cause
Grantor's Representative to cooperate promptly and diligently with Grantee in
furtherance of expediting this survey inspection process and will join in� such
documentation as may be reasonably necessary or appropriate for this purpose. Grantee
will provide Grantor's Representative with a copy of the inspection video made prior to
the commencement of Construction.
3
J:\Chaleu at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
(ii) Grantee will install and maintain monument measuring devices
(the "Monument Devices") for purposes of detecting any Material Movement and
Grantor's engineer will be permitted to review the monitoring program on an ongoing
basis. The Monument Devices shall be affixed to the Servient Improvements at locations
and in numbers adequate for this detection process, as determined by Grantee in
accordance with ordinary construction practices. Initial readings of the Monument
Devices will be taken prior to any Construction and/or Excavation (as defined below) in
order to augment the survey inspection and establish the then e�sting condition of the
Servient Improvements as reflected by the Monument Devices. Grantee shall also
engage a qualified surveyor or engineer to install the Monument Devices, to take readings
therefrom as set forth below, and to otherwise consult with and furnish customary
services to Grantee for monitoring and detecting any Material Movement. The readings
from the Monument Devices shall be taken (A) twice a week beginning at such time as
Excavation has commenced and continuing until the underpinning is complete (unless the
parties mutually agree in writing to less frequent readings) and (B) one time per month
thereafter until the Front Door Project is completed (as evidenced by the Town's issuance
of temporary or permanent certificates of occupancy for the building improvements
within the Front Door Project). Soldier beams will be installed as part of the Shoring
System on or adjacent to the Front Door Properiy (but not within the Servient Estate)
before the Construction, and perhaps several months in advance thereof, and the
installation of those soldier beams will not necessitate the commencement of monitoring
from the Monument Devices. "Excavation" shall mean the undertaking of construction
excavation for the Front Door Project within the Front Door Property. Grantee, in the
ordinary course of construction, will keep Grantor's Representative promptly apprised of �
and provide Grantor's Representative and Grantor's engineer with the results and data
from readings of the Monument Devices, and upon request of Grantor's Representative
from time to time, will otherwise consult reasonably with Grantor's Representative on the
status of the Construction activities in relation to the provisions of this Agreement.
(iii) In the event any readings from the Monument Devices detect any
Material Movement, then Grantee shall immediately institute all measures reasonably
necessary to prevent any further Construction Damage that may result from the ongoing
Construction process, and shall also be obligated to undertake any and all repairs
necessary to remedy the Construction Damage already caused, including return of the
footings to their original position if possible and if recommended by Grantor's engineer
and required by Grantor. In that regard, Grantee shall have prepared and furnished to
Grantor's Representative proposed plans for any repairs and the proposed general
contractor to undertake the same, both of which will be subject to the prior written
approval of Grantor (which shall not be unreasonably withheld or delayed). Grantee shall
be fizlly liable for any Construction Damage and the requisite repairs therefor pursuant to
Grantee's indemnity under Section 4 below.
(iv) Grantor shall designate one individual to act for Grantor and
represent the interests of Grantor and its Members in connection with this Agreement for
purposes of communicating and dealing with Grantee ("Grantor's Representative").
4
J:\Chalets at the Lodge at Vail�Eazemenu\Tieback Easement-LTS-FINAL-OS-23-06.doc
Grantor shall designate Grantor's Representative by notice to Grantee given within three
(3)business days after the date of this Agreement. Thereafter, Grantor at its election may
change Grantor's Representative upon further written notice to Grantee. In any case only
one individual may serve as Grantor's Representative at any time. Approvals given or
other determinations made by Grantor's Representative in the course of dealings with
Grantee shall be binding upon Grantor and its Members. Grantee sha.il promptly
reimburse Grantor for the reasonable cost of Grantor's consulting engineer employed by
Grantor to specifically perform engineering work on behalf of Grantor in connection with
this Agreement.
(v) Grantee will be afforded access to the surface of the Servient
Estate and the Servient Improvements (including individual condominium units therein)
as reasonably necessary or appropriate in connection with the implementation of the
monitoring and other functions and provisions of this Section 2(c).
3. Non-Exclusive• Quiet Enjovment. The Easement shall be non-exclusive, and
Grantor, on its own behalf and on behalf of its Members, expressly reserves the right to the use,
enjoyment and occupancy of the surface of and all other portions of the Servient Estate for any
and all purposes that are not inconsistent with the terms of the Easement and the rights and
interests afforded to Grantee under the terms hereo£ Grantor, on its on behalf and on behalf of
its Members, specifically agrees that none of them shall do or permit anything to be done which
physically disturbs or impairs the function of the Tiebacks during the course of the Construction
or the development of the Front Door Project, or which otherwise violates or materially
interferes with the use and enjoyment of the Easement by Grantee or the other Permittees.
4. Indemnitv. To the fullest extent permitted by law, Grantee shall indemnify and
defend Grantor and its Members, their guests, invitees, employees and agents, and their
successors and assigns, and shall hold each of them hannless from and against (i) any physical
damage to the property of such indemnified parties or any personal injuries suffered by them
(including Construction Damage to the Servient Improvements), and (ii) any liabilities suffered
or incurred by such indemnified parties as a result of any personal injury or physical damage to
property suffered by third parties, if caused, in whole or in part, by the undertaking of the
Construction, any act or omission, including without limitation negligence or willful misconduct,
of Grantee and its agents, employees, contractors, subcontractors, suppliers, workers or assigns,
occurring in relation to the use and enjoyment of the Easement, or any breach of Grantee's
obligations under this Agreement. This indemnity will also apply to and include costs and
expenses, including reasonable attorneys' fees, incurred by the indemnified parties in connection
with any indemnified matter. Notwithstanding any implications to the contrary in the foregoing
provisions,the foregoing shall not be construed to waive or limit any requirements imposed upon
the indemnified parties by law to mitigate its damages, and this indemnity sha11 not apply to
matters stemming solely from the negligence, willful misconduct or breach of this Agreement by
Grantor and/or any Member(s).
5. Remedies• Attornevs' Fees.
5
J:\Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
(a) The rights of either party hereunder may be enforced by any remedies
available at law or equity, including, without limitation, the recovery of damages, and where
appropriate, injunctive or other equitable relief to prevent the occurrence or continuance of any
default hereunder, or to enforce the performance and observance of the terms of this Agreement.
All remedies shall be cumulative with and in addition to, and not exclusive of, one another; any
and all remedies may be pursued by the non-defaulting party either successively or concurrently;
and the exercise of any one remedy shall not be construed as or constitute a bar to the exercise of
any other remedy.
(b) In the event any legal proceeding arises out of this Agreement and is
prosecuted to final judgment, the prevailing party shall recover from the other party all of the
prevailing party's costs and expenses incurred in connection therewith, including reasonable
attorneys' fees (and any presiding court will be bound to make this award). Should the
application of this provision in any circumstance prove to conflict with any other provision of
this Agreement for the allocation of attorneys' fees, this provision shall be controlling.
6. Successors in Interest; Assi�nment. The rights, interests and obligations of the
parties under this Agreement, including the Easement, shall touch and concern and run with the
land as a benefit and burden to the ownership of the Servient Estate and the Front Door Property.
All references herein to the "Grantor" shall be deemed to encompass and include its constituent
Members, and Crrantor shall be obligated to use it best efforts to cause its Members to abide by,
conform to, and refrain from violating Grantor's express obligations and duties hereunder. With
respect to Grantee, the Easement shall constitute an easement in gross in favor of Grantee, and
Grantee's interests therein and under this Agreement shall not run to the benefit of any owner of
the Front Door Property, unless and until Grantee makes and records an assignment of such
interests to such owner pursuant to an assignment and assumption agreement ("Assignment") in
a form acceptable to Grantor. The Easement and this Agreement will be assignable by Grantee
subject to Grantor's written approval of the Assignment and such assignee, which approval will
not be unreasonably withheld or delayed. Notwithstanding any such succession of ownership
interests in the Front Door Property, Vail Resorts Development Company will remain liable for
its obligations as Grantee hereunder. No owner of the Front Door Property, or any portion
thereof, will have any obligation for any of Grantee's obligations hereunder, except as provided
in such recorded Assignment (provided that the foregoing will not be construed to limit any
liability or obligations of any successor to Grantee by operation of corporate law, whether
pursuant to a merger, consolidation, sale of all or substantially all of the assets of Grantee or
other similar corporate transaction, regardless of whether such successor by operation of
corporate law has any interest in and to the Front Door Property, or any portion thereo fl.
Notwithstanding the execution and recording of an Assignment, Vail Resorts Development
Company shall remain liable to Grantor for all obligations of Grantee hereunder.
7. Authori . Grantee hereby represents to Grantor that Grantee has taken or
received all corporate action or authorization necessary for Grantee to enter into this Agreement;
that Grantee's entry into this Agreement constitutes the duly authorized corporate action of
Grantee; and that this Agreement is binding on Grantee. Grantor in turn represents to Grantee
that Grantor has taken all actions and received all consents or authorizations from its board of
directors pursuant to the Development and Use Agreement dated August 13, 2002 and the First
6
J:\Chalets at the Lodge at Vail�Easemenu\Tieback Easement-LTS-FINAL-OS-23-06.doc
Amendment thereto dated March 31, 2004 executed by Grantor and Vail Resorts Development
Company (however denominated) andlor its Members which are requisite to Crrantor's entry into
this Agreement; that Grantor's entry into this Agreement constitutes the duly authorized
corporate and association action of Grantor; and that this Agreement is binding on Grantor and
its constituent Members.
8. Completion of Construction. Unless sooner terminated in accordance with
Section 1(b) herein, upon the completion of the construction of the Front Door Project, as such
completion is defined in Section 1(b) above, the Easement sha11 terminate, Grantor and its
Members shall hold the Servient Estate free from the Easement, and Grantee will have no further
right to the use and enjoyment of the Easement or Tiebacks and shall be deemed to have
abandoned the same. Upon such termination of the Easement, it is understood that the Tiebacks
will be abandoned in place on the Servient Estate, and Grantee shall have no obligation or duty
to remove the same. Upon such abandonment, Grantor, in turn and at its election and without
obligation to Grantee, may leave the Tiebacks in place or otherwise manage, treat or dispose of
the Tiebacks in any manner permitted by law, and Grantee will have no further obligation in
connection with the Tiebacks commencing from and after such abandonment. Upon the
termination of the Easement due to completion of construction or otherwise, either party, upon
the request of the other, shall execute and deliver a recordable instrument confirming that such
termination has occurred, and that the parties are released from any further obligations and duties
hereunder. Notwithstanding any transfer of the Front Door Property or any portion thereof,
Grantee will retain the right and power to confirm termination, unless such right and power are
expressly assigned of record.
9. Severabilitv. If any term, covenant, condition or provision of this Agreement
shall, at any time or to any extent, be invalid or unenforceable, the remainder of this Agreement
shall not be affected thereby, it being the intent of the parties that this Agreement and each
provision hereof shall be enforceable and enforced to the fullest extent permitted by law.
10. Entire Agreement. This Agreement and any other contracts or agreements
specifically referred to herein represent the entire agreement between the parties hereto with
respect to the subject matter hereof, and all prior or extrinsic agreements, understandings or
negotiations shall be deemed merged herein. All Exhibits referred to in this Agreement as
attached hereto are hereby deemed incorporated into this Agreement and made a part hereof.
11. Rules of Construction. The headings which appear in this Agreement are for
purposes of convenience and reference and are not in any sense to be construed as modifying the
paragraphs in which they appear. References herein to the singular shall include the plural, and
to the plural shall include the singular, and any reference to any one gender shall be deemed to
include and be applicable to all genders.
12. Governing Law. This Agreement shall be governed by and construed in
accordance with the laws of the State of Colorado.
13. Modification and Waiver. No purported modification of the terms of this
Agreement, or purported waiver by any party of any of its rights and interests hereunder, shall be
7
J:\Chaleu at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
binding unless and except to the extent specifically set forth in a written instrument executed by
the party against whom enforcement of the purported modification or waiver is sought.
14. Counterparts. This Agreement may be executed in counterparts, each of which
shall be deemed an original, and all of which together shall constitute one and the same
instrument and agreement.
15. Notices; Business Davs. Any notice required or permitted under the terms of this
Agreement shall be in writing, may be given by the parties hereto or such parties' respective
legal counsel, and shall be deemed given and received (i) when hand delivered to the intended
recipient, by whatever means; (ii) three (3) business days after the same is deposited in the
United States mails, with adequate postage prepaid, and sent by registered or certified mail, with
return receipt requested; (iii) one (1) business day after the same is deposited with an overnight
courier service of national or international reputation having a delivery area encompassing the
address of the intended recipient, with the delivery charges prepaid; or (iv) when received via
facsimile on the intended recipient's facsimile facilities accessed by the applicable telephone
number set forth below (provided such facsimile delivery and receipt is confirmed on the
facsimile facilities of the noticing party). Any notice under clause (i), (ii) or (iii) above shall be
delivered or mailed, as the case may be, to the appropriate address set forth below.
If to Grantee:
Vail Resorts Development Company
Post Office Box 959
137 Benchmark Road
Avon, Colorado 81620
Attention: Jack Hunn, Senior Vice President
Fax No.: (970) 845-2555
Phone: (970) 845-2359
With a copy to:
Vail Resorts Development Company
Legal Department
Post Office Box 959
137 Benchmark Road
Avon, Colorado 81620
Attention: Julie A. Stencel, Esq.
Fax No.: (970) 845-2555
Phone: (970) 845-2548
8
J:\Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
If to Grantor:
Lodge Tower Condominium Association, Inc.
200 Vail Road
Vail, Colorado 81657
Attention: Stan Cope
Fax No.: 970-476-4093
Phone: 970-476-9530
With a copy to:
Richard A Hardaway, Esq.
Isaacson Rosenbaum P.C.
633 Seventeenth Street, Suite 2200
Fax No.: 303-292-3152
Phone: 303-292-5656
Either party may change its addresses and/or f� numbers for notices pursuant to a written notice
which is given in accordance with the terms hereo£ Any notice may be given on behalf of a
pariy by its legal counsel. As used herein, the term"business day" shall mean any day other than
a Saturday, a Sunday, or a legal holiday for which U.S. mail service is not provided. Whenever
any date or the expiration of any period specified under this Agreement falls on a day other than
a business day, then such date or period shall be deemed extended to the next succeeding
business day thereafter.
16. Recording: This Agreement may be recorded in the Records at the election and
expense of Grantee.
17. Insurance. Grantee covenants and agrees to obtain and keep in full force and
effect during the term of this Easement,through its contractor(s):
(a) Liability Insurance. Commercial general liability insurance with respect
to the Construction and Tiebacks, covering bodily injury, death and damage to property of others
with endorsements for liability with respect to any and all claims against which Grantee has
agreed to indemnify Grantor, as required above, personal injury insurance, premises insurance,
products/completed, operations hazard insurance, broad-form property damage insurance,
worker's compensation insurance and independent contractor's insurance.
(b) Insurance Amounts. Insurance obtained by Grantee shall be canied with
combined single limits of not less than $11,000,000 in respect to any one accident of occurrence,
and shall be carried on a full replacement cost basis subject to only such deductibles and
exclusions as Grantor may reasonably approve.
(c) �ieneral Reguirements. Except as otherwise approved in writing by
Grantor, all insurance obtained by Grantee shall be carried on a claims made and occu.rrence
basis; shall name Grantor, its Members and its management company as additional insured
parties, as their interests may appear; shall be written as primary policies, not contributing with
9
J:\Chafets at the Lodge at Vail\Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
and not in addition to coverage that Grantor may carry; and sha11 provide, by certificate of
insurance or otherwise, that the insurance coverage shall not be cancelled or altered except upon
forty five (45) days' prior written notice to Grantor. All general liability insurance policies shall
contain a provision that Grantor and any of its Members, although named as additional insureds,
shall nevertheless be entitled to recover under such policies for any loss sustained by either of
them, notwithstanding any negligence by Grantee. All such insurance policies shall include a
waiver of subrogation endorsement in favor of Grantor and its Members.
(d) Evidence of Insurance. Grantee shall obtain and file with Grantor before
commencement of Construction certificates of insurance, the declaration page and a copy of the
applicable policy or binder in effect evidencing the insurance coverage required above, and shall
deliver such certificates to Grantor, and from time to time thereafter as may be reasonably
required by Grantor to establish Grantee's insurance coverage.
IN WITNESS WHEREOF, Grantor and Grantee have made this Construction Easement
Agreement as of the day, month and year first above written.
GRANTOR: �
Lodge Tower Condominium Association, Inc., a
Colorado nonprofit corporation
��
� ;:,✓' %�
;,�
gy; �.% �='. cv��;��'`�.:c,
Name: 'a;�'� c�- ,��i�/�v�l•�t�
Title: �-z�,.���✓r^
�
__�
STATE OF__���_ )
) ss:
COUNTY OF �� a� )
The foregoing instrument was acknowledged before me this �� day of
.�.�, 2006, by as
of Lodge To r Condominium Association, Inc., a Colorado nonprofit corporation.
Witness my hand and ofFicial seal.
My commission expires: .
�C�-- � �
""""'�� PAUTA SANCHEZ
�.?e��:`�r°°;% No ry Public
'�: Notary Public,State of Texas
My Commission Expires
'•'�roi�E:;� ber D8,2008
'•,.,,,������
Septem
10
J:\Chaleu at the Lodge at Vail�Easemenu\Tieback Easement-LTS-FINAL-OS-23-06.doc
GRANTEE:
Vail Resorts Development Company, a
Colorado corporation
By:
N e: Jac H
Tit� : Seni r Vi President
STATE OF COLORADO )
) ss:
COUNTY OF �- a- ` �
��, ,�n
The foregoing instrument was acknowledged before.me this, 3 u ` day of , ► L ,
2006, by �'c�r � � u-�'1�'l � S�n,or �!� c.e��es �C�'P�1, of Vai Resorts
Development Company, a Colorado corporation.
Witness my hand and official seal.
My commission expires:
�k.Io�.a S� 0 Q,���.►�.
S. AO� Notary Public
0Q:4'�'�A���'•�y
a�v.�o q�- :o
. .
. .
. .
: :
N'. A �j :�O
�►,��� FBC��OPP
�lu�$$jp��1f2S�/� ,-S�iprnrtci ac ta:�cyrsi: ,xtme
m�
*,_c!Y?c
t'aii{icc:�tt .
�': � � EL—
. �?L�E 5--�_.
.:�t�tc: _ � �O/
,�� o
flate•
ll
J:\Chalets at the Lodge at Vaif�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
Exhibit A
Legal Description Of
Front Door Property
PARCEL 1
LOTS 1 AND 2,
MILL CREEK SUBDIVISION,
ACCORDING TO THE PLAT THEREOF
RECORDED NOVEMBER 6, 2000, AT RECEPTION NO. 743366,
COUNTY OF EAGLE,
STATE OF COLORADO �
A-1
J:\Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
E�chibit B
Plans
B-1
J:1Chalets at the Lodge at Vail�Easements\Tieback Easement-LTS-FINAL-OS-23-06.doc
F'
DESIGN CALCULATIONS
Submitted to:
Hyder Construction, Inc.
for:
Vail Front Door-
East Excavation Shoring REVIEWED B
VAIL, COLOR.ADO
�tAY 2 6 Z008
by:
COLQRADO INSPECTION
AGENCY
SCHNABEL FOUNDATION COMPANY
Job No. 07-3715
�����,� �� ���� Apri13, 2006
� :� � �.;.�
�'��,,p�,�� �� �"^���q��''�M
� �a �����a " �� 01��F� � �
,� a°��s• 'f�f'�14� .F �`:�'?L
T�ais �}amp certif's�s that this she� u:�� �°�"�'����
dra�,rWin� F�a� been reviewed for its basic ` + ��,�� ' e `��
, con�r�;a�c;4a�ifh the Contr�ct �ocuments. • ; .��'�
r L� t;
; How�ver, it aoes not r�;l;eve thc � �
. siahc:;ar��r�ccor or ��endar trom any `��'��,.4ao5' v��:,.��
' c�;�tr�.�;���1 naiiqations. ,,, w�,���,�.�,��'
� : :. �„ ,,�„�;.
'ri;rr'er�anstruction:�,����
�i�bm�tt�.�r��-� D�¢e:y�i��Q�,
John A. Franceski
COLORADO P.E. #28034
� _� L�= __ f
� � APR 1 � 2006 i
S chnab el ��►id- �
FOUNDATION COMPANY TOW� O F VA I L
�, '�"��"����� Calculation Sheets
�=�(.,t:v"Cl1�TI�JN C[?iirfl�t°1��.'"k'
Project: Vail Front Door Contract No.: 07-3715
Location: Vail,CO. Sheet No.: _
Owner: VRDC Date: Apr. 3,2006
General Contractor: Hyder Construction, Inc.
LOADING GONDiT1L1N�
— 'WtNGED SUPPORT ASSUA�ED AT EAGH BRACE OR TIEB!►CK EXGEPT TQP 11EFc
— HINGED SUPPOi7T ASSU�SED AT SUHGRADE
— SYSFEM :IS FREE—DI�AtNiNG {NO HYDROSTA7I�C PRESSURE)
— LC?1�ING QI,+1�fftAXt�ll (NCLUtiES SURCHAF2GE FQR TRAFFlC AND NQRMAL GONSTRUGTIQN LOADS
(HEAW LOADS SUCH AS GRANES NOT INCLUDEDj
— 1NHERE APPUCABLE, UP TO 33?: REDUC?tON MAY BE 7AKEN iN S4LDIER BEA1►d MOMENTS
PER; FOUNDATION ENGINEERING; #'ECK,
HANSQN dc TH�RH�U:RN; 1974; Pp — 453—#63
— ALL ANCHORS TO BE LaCATED BEHINO FAILURE PLANE AS FOLLOWS
'`�` ,�\. T_'�.y!''T�
UNHONDED �
1.ENGTH �
1 ANGHt}R IENGTN BEYOND
FAlLURE PLANE
!
/
/
/
!
!
/ 6�'
r
�� ,!i'��/' '\���
— YALUES SHOWN JN T'HE GALCULATIONS ARE TAKEN FROM A COiulPUTER PRIM'Ot.!i"
— ONLY THE GRITlCAt A�OM�hiT IS SHOtNN !M THE CALCl1LATiONS
— ALL�WABLE BENDING S?RESS FOR STEEL = 0.66Fy SINCE �L.ANGES ARE FULIY
StJPPG1RTED thl THE PLANE OF BENDING
�
�,���"����� Calculation Sheets
���c��.�nar� cc���.r���
Project: Vail Front Door Contract No.: 07-3715
Location: Vail, CO. Sheet No.:
Owner: VRDC Date: Apr.3,2006
General Contractor: Hyder Construction, Inc.
EXISTING GRADE {TYP.}'
.2H
�� H = NEIGHT OF SOIL tN FEET
H 1 = DEPTH TO TIEBACK IH FEET
M2 = DEP7H FROM TIEBACK TO SUBGRADE IN FEET
�„�} B1 = NORIZONTA� T1E8ACK GOAD IN KIPS/FT
B� M1 = 50LDIER 9EAM Mpf�ENT A7 TIEBIICK 1N K—fTfiT
� , MMt = MAXlbiUM SOLDIER BEAM 1�IOMENT BETWE�N .
.� TIEHACK AN[] SUBGRADE 1N K-FT/FT
° �IM1 .6H
� �
H2
.xH 07'f0�t OF ;EXCAYATION
LOAD tNTENStTY INCLUDES SURCNARGE dUE TO
P-.025H' NORMAL CON5TRUCTION LOAQS� AND TRAFFIC
LOADING DIAGRAM FOR ONE-TIER TIEBACK SYSTEM
,����"���, '�"sl Calculation Sheets
F{��,�'�1C�,�1.TZOi; G+�:�.213r�1i'!'
Project: Vail Front Door Contract No.: 07-3715
Location: Vail, CO. Sheet No.:
Owner: VRDC Date: Apr. 3,2006
General Contractor: Hyder Construction, Inc.
\ �'�-',�,�r�'
P�= ACTIYE EARTH PRE55URE (ACTS QN CONTRIBUTORY
WIDTH OF SHORING T0 50LOIER BEdM AB�YE THE
BOTTOM OF EXGAYATION, 4N WIDTH OF SOLDIER
BEAM BELOW THE BOTTOM OF EXCAYATION)
Pp= PASSIVE E,ARtH PRESSIYE (AGTS UPON THREE
H, TIMES DRIYEN BEAM WIDTH, THREE TIWES THE
DRIIL HOLE DIAAtETER, OR SOLDIER BEAA1 SPACING,
WHiCHEVER IS LESS}
H = QESIGN NEIGHT IN FEET
H H'= HEIGHT TQ' TOP OF SIOPE IN fEET
BOTTOM SPACING = DISTANCE FRQM CENTER TO CENTER QF SOLDIER -
OF BEAM
EXCAVATION K' = W�DTH OF QRIVEN BEAM OR 'CIRILL HOI.E DIAMETER
D = TOE PENETRATION IN FEET (DKIIN=H)
MMAX = MAXIMUM MOMENT IN SOIDIER BEAM iN KIP—FEET
FB = ALLOWABLE BENOINC STRE55 OF STEEL SOlD1ER '
� BEAM IN KSI
SREQ = REQUIRED SECTION MODUIUS IN CU81C !INCHES
Lt�iN = MtNIMUM LENGTH OF SOLdtER BEA�i H+D(IMIN=2•H)
D Ai .
��PP �PA�
EARTH PRESSURE DIAGRAM - GANTILEY�RED RETENTION SYSTEM
• �� ��� Calculation Sheets
FOLJl\TDATIOl� GOi1�fI'A,.a�V'Y
Project: Vail Front Door II Contract No.: 07-3715
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 4, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #15: Soldier Beams 30-35, 38-41, 46
Desiqn parameters for a one tier svstem:
H= 11 ft (design height)
H1 =4 ft (depth to tieback row)
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B 1 = 1.901 kips
B1•S
DLT1 := DLT1 =20.235 kips
cos�a��1 ft
use#8� 75ksi bar L„:= 7ft
La:= 15ft
SOLDIER BEAM DESIGN
M1 =—1.212kips•ft
MMlt= 1.004kips•ft
Mmax:= 1.212kips. ft
lf
Sreq�= Mmax'S Sreq=4.407 in3
0.66•Fb
use 2-C10x15.3 Sall�= 2�1n3
Copyright 2005,Schnabel Foundation Company
' �� ��� Calculation Sheets
Fou�a�zo�v cc����a�
Project: Vail Front Door II Contract No.: 07-3715
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 4, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #16: Soldier Beams 36-37 (cantilevered)
Desiqn parameters for a cantilevered system:
kips kips
H= 7 ft (design height) Pa=0.034— P =0.35—
ft3 p ft3
S= 10 ft (spacing)
SOLDIER BEAM DESIGN
Mmax=35.631 kips�ft
Sreq•_ Mmax Sreg= 12.957 in3 use W 14x22 S 29in3
0.66•Fb all �_
L,,,;,, = 14 ft
Case #17: Soldier Beams 27-29 (cantilevered)
Desiqn parameters for a cantilevered svstem:
kips kips
H=9 ft (design height) Pa=0.034— PP= 0.35—
ft3 ft3
S= 10 ft (spacing)
SOLDIER BEAM DESIGN
Mmax= �5.73kips•ft
S1eq._ Mmax Sreq=2�•53g�n3 useW14x26 S 35.3in3
0.66•Fb all�_
L,,,;n = 18 ft
Copyright 2005,Schnabel Foundation Company
�� b�l Calculation Sheets
FoUNDATI4IV CC)MPt�Y'
Project: Vail Front Door II Contract No.: 07-3715
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 3, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #18: Soldier Beams 47-50
Desiqn parameters for a one tier svstem:
H= 17 ft (design height)
H1 =7 ft (depth to tieback row)
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B1 =4913kips
B1�S
DLT1 := DLTI =52.283 kips
cos�a�•1 ft
use 1"� 75ksi bar Lu'— �ft
La:= 20ft
SOLDIER BEAM DESIGN
Ml =—6.174kips•ft
MMlt= 2.154kips•ft
Mmax�= 6.1�4kips•ft
lf
Sre9._ Mmax's Sreq= 22.451 in3
0.66�Fb
use 2-C10x15.3 Sall�= 2�1n3
Copyright 2005,Schnabei Foundation Company
' s� ��� Caiculation Sheets
FOi1NDAT`I.Oi� CC)MPA�T'Y
Project: Vail Front Door il Contract No.: 07-3715
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 3, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #19: Soldier Beams 51-54
Desiqn parameters for a one tier svstem:
H=21 ft (design height)
H1 =9 ft (depth to tieback row)
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B 1 =7.718 kips
B1•S
DLT1 := DLT1 = 82.128 kips
cos�a�•1 ft
use 1-1/4"� 150ksi bar Lu'— �ft
La:= 20ft
SOLDIER BEAM DESIGN
M1 =—12.883 kips•ft
MMIt= 3.087kips•ft
Mmax�= 12.833kips• ft
lf
sreq= Mm� S Sreq=46.665 in3
0.66�Fb
use 2-W14x22 Sall�= 58in3
Copyright 2005,Schnabel Foundation Company
� �� b�l Calculation Sheets
FOLJNDA'I'IOi� CO��II',F1.NY
Project: Vail Front Door II Contract No.: 07-3715
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 3, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #20: Soldier Beams 26 (cantilevered)
Desiqn parameters for a cantilevered system:
H= 16 ft (design height) Pa=0.034 kips p =0.35 kips
P
ft3 ft3
S= 10 ft (spacing)
SOLDIER BEAM DESIGN
Mm�=319.125 kips•ft
Sreq._ Mmax Sreq= 116.045 in3 use W 18x65 S 117in3
0.66�Fb all�_
L,,,;,, =32 ft
Copyright 2005,Schnabel Foundation Company
. �� 1 Calculation Sheets
�C
FOLINDATIUN COMPANY
Project: Vail Front Door II Contract No.: 07-3715�
Location: East Wall Building A Shoring Sheet No.:
Owner: VRDC Date: April 4, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #21 : Soldier Beams 42-45
Desiqn parameters for a one tier svstem:
H= 14 ft (design height)
H1 =4 ft (depth to tieback row)
S= 10 ft (spacing)
a = 20 deg
TIEBACK DESIGN
B 1 =2.744 kips
B1•S
DLT1 := DLT1 =29.201 kips
cos�a�•1 ft
use#8� 75ksi bar Lu:= 7ft
La:= 20ft
SOLDIER BEAM DESIGN
M1 =—1.297kips•ft
MM1 =3.401 kips•ft
Mmax�= 3.401kips• ft
]f
Sreq._ Mmax'S STeq= 12.367 in3
0.66•Fb
use 2-C10x15.3 Sall �= 27in3
Copyright 2005,Schnabel Foundation Company
` r
�
DESIGN CALCULATIONS
Submitted to:
Hyder Construction, Inc.
for: .
Vail Front Door-
South Tunnel, South Wall & West Wall
Excavation Shoring
VAIL, COLORADO
�y:
REVIEW D By
SCHNABEL FOUNDATION COMPANY
Job No. 07-3715 MAY 2 6 006
February 17, 20.06
COLORADOINS CTION
AGfNCY
G��.��0 RE��u� ��
c:;;��'�RA'y�'�:;��'R,
U"�
. �.fl
.
a� 2f�!�4�
•
�: .. 7'4
� . V�
��.
� ��`��.�
s ...... �
��NAL E�
John A. Franceski
COLORADO P.E.#28034
Schnabel
FOUNDATION COMPANY
� a •
` ������,��� Calculation Sheets
FQ�f1,TI0�' CQi1��A,Z!'Y Contract No.:07-3715
Pro'ect: Vail Front Door Sheet No.: I o
� Date: February 17,2006
Location: Vail,CO. �y: CHB
Owner: VRDC Rev.By:JAF
South Wall Permanent Shorinq
BEDROCK EXCAVATION:
For excavations in bedrock the following design parameters were used:
Allowable bedrock/grout adhesion: 100 psi
Diameter of drill hole: 3-3/4" '
Rock bolt angle(from horizontal) 1 S degrees
Phi of bedrock: 40 degrees
Surcharge pressure: 130 psf* Ho„e�b�raen (2:1 slope)
From the above parameters the minimum required rock bolt length is calculated using the
equation below_The equation gives the distance required to reach the critical failure wedge(see
attached sheets)plus the reyuired bond length for any given height of rock excavation.This
equation is provided because the actual depth to bedrock is currently estimated and in no situation
will rock bolts be installed that are shorter than this equation allows.
Minimum nait length (ft.)=0.5727 x Height above subgrade+9.903
The permanent facing will consist of a 6-0"thick layer of 4000 ps.i. shotcrete with 6 x 6-W2.9 x
W2.9 welded wire mesh. The rock bolt heads will have a 8"x 8"x 7/8"thick plate with four'/e"0
x 5"shear studs spaced 6"apart.The plate thickness includes 1/8"of sacrificial steel as corrosion
protection.
The rock bolts will be installed such that the upper row of bolts is no deeper than 4' below the top
of bedrock.The bolts will be spaced eveniy on an 8'x 8' grid pattern with no more than 64
square feet per bolt. All rock bolts will be epoxy coated 150ksi bar.
SOIL EXCAVATION
The shoring along the South Wall, above bedrock consists of tiebacks (anchoring 100
square feet each)and blocks (5' x 5') against a permanent shotcrete facing. The tieback. .
loads were calculated using the greater of a 0.025 x Hso;�trapezoid loading diagram
modified to include applicable surcharges (25(lpsf+a 2:1 infinite backslope)or global
stability analysis using the computer program Slope/W. The required unbonded length
however was,in all cases, calculated based on global stability(F.S. = 1.5). Soil
parameters for the Slope/W analysis were c=0,phi=30 degrees, gamma= 130 pcf.
Attached are the graphical outputs from Slope/W and a summary of the design loads
calculated for internal stability.Also attached are calculation sheets for the shotcrete
tieback blocks and permanent shotcrete facing.
1������;�,��� Calculation Sheets
FflL3i�1�A'ITOI\ Cnb4PA,1�TY Contract No.: 07-3715
Pro'ect: Vail Front Door Sheet No.: 2�,,;�4-
1 Date: February 17,2006
Location: Vail,CO. By. �HB
Owner: VRDC Rev.By.JAF
South Wall Permanent Shorinq
TIEBACK ANCHOR DESIGN SUMMARY
� .
Design Summary
Height=40 feet
Design loads(Lu,Lb,design control,tieback type):
Tier 1 125 kips(Lu 20', Lb 30', global,4-0.6"strand)
Tier 2 120 kips (Lu 18', Lb 25', global,4-0.6" strand)
Tier 3 115 kips(Lu 15', Lb 25', global,4-0.6"strand)
Tier 4 80 kips(Lu 15',Lb 20', global, 3-Q.6"strand)
Design Summary
Height=30 feet
Design loads(Unbonded lengths):
Tier 1 74 kips(Lu 15',Lb 20', global, 3-0.6"strand)
Tier 2 83 kips(Lu 15', Lb 20', global, 3-0.6"strand)
Tier 3 68.kips(Lu 10', Lb 20' global, 1"bar)
Design Summary
Height=20 feet
Design loads(Unbonded lengths):
Tier 1 52 kips(Lu 10', Lb 20', internal, 1"bar)
Tier 2 52 kips (Lu 10', Lb 20', internal, 1"baz)
*All strands 270 ksi double corrosion protected.
f
�����li��L.� Calculation Sheets
FCQU�r`UAT`IOI�i COiVff'A.r\'Y Contract No.:07-3715
Project: Vail Front Door Sheet No.: 3�5 0
Location:Vail,CO. Date: February 17,2006
Owner: VRDC By� Cyg
Rev.By:JAF
South Wall Permanent Shorinq
20' Soil Height—Internal Stability
TIEBACK LOADS
Vai! Frant Door
20'DLT Yerification •
Depn(g
D ---------------------------------------------------=-------------
5 �
to
ts �
� ---------
n ��L
I I
=strazn :c fr ra Gust7€CrFSO�A�A.....sut:��3h�ts r�ics2>�ssase
Licensed to C Baxter Schnabel Foundation
Date 8 Time2t13/2006 7.36:11 PM File Name: ,
WALLHEGMT:�L�O ELi8E01dENT:OD� PkELENGTH:��6
61.1X..puAtENT:iu� AT DEPTN:tODO
TIEBPf KFUP.CE:
T1E6°rEK 'I�TAL HOP.Q. VEP.T. DEPTFf ANGLE
1 56.J0 SO.W OLO SLO OID
2 W.lO SD.W OPO bA0 DPO
Tt�TAL VEP.Tk:?L FO P.0 E:�11C4
Loading diagram 0.031 S x H
otal horizontal load= 101 ki
����11���� Caiculation Sheets
F�LINDATIOiV CO�r1t`'Y .
Cor�tract No.:0 -3715
Project: Vail Front Door Sheet No.: 50
Location:Vail,CO. Date: February 17,2006
Owner: VRDC By: CHB
Rev.By:JAF
South Wall Permanent Shorinq
SLOPE/W Analysis
10D VAIL FRONT DOOR SLOPE STABILITY ANALYSIS
SOUTH WALL
so 2/17/2006
Height of soi1=20 ft.
�
�o
so
.....................
� � :s':i:'sssss'st'
� :�t.50B':::::i::
:�:.^.::
t 40
�
'� .....................
.....................
2
�
�p 2
to
o .
-�o
_Zp
30 40 50 6� 70 � 90 10D i10 120 130 740 150 160 S70 1B0
Distance(ft.)
_ _ _ _ _.. _. __ _
_. ..
Factor of Safety= 1.5
Tieback Row 1: DLT 47kips, Lu= 12'
Tieback Row 2: DLT 40kips, Lu=7'
/
I ������[���� Calculation Sheets
FQUNG1�i,TION COA�iPA,I\''fi Contract No.:07-3715 •
Project: Vail Front Door Sheet No.: 5f 5q
Location: Vail,CO. Date: February 17,2006
Owner. VRDC By: CHB
Rev.By:JAF
South Wall Permanent Shorinq
30' Soil Height—Internal Stability
TIEBACK LOADS
Vail Front Door
3D'�LT 1ler��icativn �
oepn�rg �
o -- ------------------------------------------------------------
s �
io
�s �
�
� 3
30 ----'----
0 1 y}.Y�
� �
�
�*.?Awf ?CO Cb CltFlE.TC.;S�h'.t.�`.TA':.�Sc53dtJd F3K:d2i�35d:d
Licensed to C Baxter Schnabel Foundation
Date 8 Time:2n 3C2006 234:11 PM File Name:
WP.LLNEIGHT:30DD EIIBED6IENT:ODD VILElENGTH:30DD
61?47C.NOLIENT:u'�.1� ATDEPTH:1?b5
TIE6AA:KFBP.CE:
TIEBd.t:K 7C?T.4L H9P.C. L`EP.T. OEDTH ANGLE
1 fi2,E� �Bi ODi] SLO OD7
2 75.y 795� OPU 15�D Q�D
3 fi28� �8� dIN a.� DAO
Loading diagram 0.0285 x H
otal horizontal load=205 ki
� � � �
e e • � . �
• �.. �. ,. ��.
. •
• -�
� ' - � �
� ' • � .
�� ° • �� • - • - •
�
.� li �
- � � � t
:i
:!..
� :•'•:'r.,
!0::.::•.
...,,..r.,
iiO��00i�i�.
•••.�♦ ♦ ♦
!O�'�.�:O�i�i'�i•.
•�����O���i��•
•������������r
.1 �.�.��������������`�
.����♦ •��������.
•��i�0i�i i��OO��i OiO i�i•�.
i0���������������•
•�����������������'O�,
i�����• •������������.
�Oi�60�i0 i i�i.�i i'i'Oi�ii4
i�•i�i��i Oi�'�'i i i i�i i�i�����i�
OO��������������i����
'• 0�������•���������. O�P�.
�':..'••::.❖O�.��,.•,.�.�.�.�..,
^I �'�i0'��i oi':Oii���'i�O'ii�i0'i0i%i�.
i�i����������i d�i:���i��%�O��i�i�OO��i���i`.
i0����i i�i��0i����O��00i'�i��i�i�i i0i�`
i i�i��40��i i�i�ODi yi:�i00�i i�:Pi'i i iy�i��i'��.
♦♦ • ♦����♦ •����♦ ♦��♦
������i���������si������i����������ii�. �
��������� ♦������ • ♦ •• ♦�♦ ♦��������• ♦
J��� •��ti�• •���• •��• .
� •:•:'y��• �• • •i. ..•M����• •��o:' •:'a..
� - - - - - , .._
�
�
�
� � . . . .... . �..,.;.
�,` -
� : ----�-�;.__ .
3 � .p �,�;.�
t �- �_-�---, ^"�.- -"?
�� aw x . �" =��9
- � ;i
� ';��,�, 1
,
� . ,. � � $ � � �"� V^' :4 :
9 �" �
� �5��.....:..c:.r.0 ��::.u�.�j�..z:,�a..s:i��c.�..�_...�.�1:s��:.._�.,.���:'�.i...:.�'.,...3f ��r.,,�I.:..,......._ — � i— I
1 •1 1 :1 1 :1 '1 11 1 7 1 �1 1 .� 1 :�
�
� •
"�• � � , � I
'�. � ! � i �
'�. � � � �• •
s
. ���k��.��� Calculation Sheets
�Q�7.NUATION Cni1'i�?.�1''Y Contract No.:07-3715 .
Pro ect: Vail Front Door Sheet No_: ���R�
J Date: February 17,2006
Location:Vail,CO. gy, C�{g
Owner: VRDC Rev.By:JAF
South Wall Permanent Shorinq
40' Soil Height—Internal Stability
TIEBACK LOADS
Vail Front Door
40'DLT Ver�cation
Deptl titiy '
a -----------------------------------------------------------------
s �
�a
�s •
�
� �
m
� �
�o ---------
a ��L
u � I
St��urn yc F+Reb°pW.L�i:!-/StI�:A•H,2.Ta'�?.+aS'.1dAAl:3x.'�SS5.1:4
Licensed to C Baxter Schnabel Foundation
Date 8�Time:2/1312006 2:30:37 PM File IVame:
fMLLHEGMT:lODO EHBEDYENT:ODD PILELENGTH:I�AO
1!A%.quL1ENT:1367a AT DEPTH:20f7�
TIEBPrC K fi�P.0 E:
TIE6�lCF� T07P.L H9PC. 4'EP.T. OEPTH AHCIE
I 63� 68uU ODD St0 ODQ
2 ��.� ios:�e a�o tsm om
3 iDi.% 105.Ib ODO ?5�0 Um
� ssm bsxa am �m oao
Loading diagram 0.0271 x H
`
otal horizontal load=347 ki
�
^ ��������� Calculation Sheets
P(3l.l:ti`DATTON CO�A,t�"Y Contract No.:07-3715 '
Sheet No.: 4/�o
_Project: Vail.Front Door _ - -. . - Date: February 17,2U06 .
Location:Vail,CO. By; CHB
Owner: VRDC Rev.By:JAF
South Wall Permanent Shorinq
SLOPE/W Analysis
�oo VAIL FRONT DOOR SLOPE STABILI7Y ANALYSIS "
SOUTH WALL
so 2l17l2006
Height of soii=40 ft.
so -
�o ..... .. .:.. ..
.....................
.....................
.....................
so .. ...... ..
.....................
_. _ __. . _ ___
..............1.ass.::
so • :`•:'•:T' _
� . .. . .
. . ...
�
L 40 .....................
�
.....................
,�
2
30
20
10
0
1
-10
_20
30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 1B0
Distance(ft.)
Faetor of Safety= 1_5
Tieback Row 1:DLT 125kips, Lu=20'
Tieback Row 2:DLT 120kips,Lu= 18'
Tieback Row 3: DLT 115kips,Lu= 14'
Tieback Row 4: DLT 80kips,Lu=7'
' a/5 0
- SC�111�Ib�I ` S.TABtL1TY ANALYSIS 16' rock /40' earth
Foundation Company Vail Front Door 2-17-06 _
South Wall Permanent Shoring
.. ,-� •
.�`'�'����`��' �:� ' , �-�a .; .
Total Height of WaU: ::16 ft
Wall Batter(0=verticalj: 5.7 degrees
Inclination of Backslope: ' �'0 degrees
_ ,_ . ... . . . _ .._
Of OG O� E -
Friction Angle: 40 degrees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: �:0 ft below Top of Wall �
Unit Weight-Layer 1: �.'� ::1.30 pcf
Unit Weight-Layer 2: ' .160 pcf
..�.� -
e
Water Table Location: ;=10 ft above Bottom of Wall
Pressure Head at Bottom of Wall: , 1 Zero (see drawing --►)
Pressure Factor: _,,..;,;_=;,:.;`0�5 (reduces water pressure)
Full Zero
Verticaf Point Load: ; kips Horizontal Point Load: �kips
�-► Distance Behind Toe: ,,, , ::, . ; it
Verticaf Pressure on Backslope: ��:5800 psf Horizontal Pressure on WaIL• �psf
Vertical Seismic Ccefficient: �g Horizontal Seismic Coe�cient: �g
Desired Factor of Safety: . , 1:35 Note: Factor of Safety is applied to tangent of Friction Angle.
f> ,
Dip of Critical SurFace,a: 'S7 degrees
Total Weight of Wedge,W: ::11.3 kips
Total Water Force, U: U,9 kips
Total Vertical Surcharge Load, Sv: 51.0 kips Vertical Seismic Load, E,,: ;: 0 0 kips
Total Horizontal Surcharge Load,SH: � =��0, kips Horizontal Seismic Load, EH: '�0 0 kips
Closure Angle=90-(90-�mob)-a: �:25 1: degrees
Horizontal Force Required, H: ���9,"8 kips/LF of wall
Inclination of Reinforcement: 15:0 degrees
(nclude Vert. Component of Reinforcement? �:Yes
Force Required @ fnclination,T: ;" ��5,�1 kips/LF of wall
Copyright 05/17/2005 Schnabel Foundation Company
�
� �Q�So
Excavation Geometry
. �
I
�' __._
�
__._..__..__._ ..._;... ,o
�
/ Ground Surface
, � — �Critical Surface
�, / - - - Soil interface
Water Table
0
-to o to zo
USE 8'x8' PATTERN FOR ROCK BOLTS
DLT 140kips, USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
sub rade (ft.minimum)
12 1 17
4 2 13
. Copyright 05l17/2005 Schnabel Foundation Company � �
r ��
. - �5 0
- SC�IIl�bel� STABILITY ANALYS(S 20' rock / 30' earth
Foundation Company; Vail Front Door 2-17-06
South Wall Permanenf Shoring
�,,I�:�Excaua i - e�
Total Height of Wa►I: 20 ft
Wall Batter(0=vertical): 5.7 degrees
Inclination of Backslope: :.:`0 degrees
. �j� TR C ,O f�;
Friction Angle: 40 degrees
Dip of Critical Surface: ' Search
Depth to Bottom of Layer 1: �•0 ft below Top of Wall •
Unit Weight-Layer'I: ___,,;:':;;130 pcf
Unit Weight-Layer 2: ,160 pcf _
:�a��
Water Table Location: ::�20 ft above Bottom of Wall
Pressure Head at Bottom.of Wall: �; Zero (see drawing —�)
Pressure Factor. ; 0.;5 (reduces water pressure)
Full Zero
Vertical Point Load: . kips Horizontal Point Load: �kips
�—► Distance Behind Toe: ft
Vertical Pressure on Backslope: :-'�45.50 psf Horizontal Pressure.on Wall: �psf
Vertical Seismic Coefficient: r��g Horizontal Seismic Coefficient: �9
�, .
- c ; . :- :
Desired Factor of Safety: ::�-=1:35 Note: Factor of Safety is apPlied to tangent of Friction Angle.
�
Dip of Critical Surface,a: 57 degrees
Total Weight of Wedge,W: 17;6 kips
Total Water Force, U: = 8".7 kips
Tota!Vertical Surcharge Load, S�: � 50 0 kips Vertical Seismic Load, E�: Y �Q 0 kips
Total Horizontal Surcharge Load,SH: y:', 0 0 kips Horizontal Seismic Load, EH: �,� 0 0 kips
Closure Angle=90-(90-4>mob�-Q• ;25=?k degrees
Horizontal Force Required, H: °`'",�33�9. kips/LF of wall
Inclination of Reinforcement: ,"1.5:0 degrees
Include Vert.Component of Reinforcement? '.. _.,Yes
Force Required @ Inclination,T: '��T.s�,"`"44�1, kips/LF of wall
_. , .. Copyright OS/17/2005 Schnabel Founda6on Company
. �Z/
' fj0
� Excavation Geometry
30
20
�
�:
° ; _ � ! , ; 10 ' Ground Surface
/ — —Critical Surface
� � SoillnterFace
� Water Table
0
-10 Q 10 20 30 ,
USE 8'x8'PATTERN FOR ROCK BOLTS
DLT 129kips, USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
sub rade (ft.minimum)
16 1 20
8 2 15
4 3 13
Copyright 05/17/2005 Schnabet Foundation Company
� �3
► �3°
• SC�IIl�.`beI ' � STABILITY ANALYSIS 25' rock / 30' earth
Rounda:tio'n Gompany: '�< Vail Front Door 2-47-06_
South Wall Permanent Shoring
�I�I��XC���lO�� ;
_ -.,......, �,.�.,��:�h .� .
Total Height of Wall: 25 ft
Wali Batter(0=vertical): 5_7 degrees
Inclination of Backsiope: � 0 degrees
,�.. O,I����,, O.� ef�l„_S'_
«a.-�.�.�.�..,.W..,.. ..�,.��p�,.�., . .
Friction Angle: � 40 degrees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: `0 ft below Top of Wall �
Unit Weight-Layer 1: :; 1.30 pcf
Unit Weight-Layer 2: '�` 1.6.0 pcf
�U
e �;_ .
Water Table Location: :25 ft above Bottom of Wall
Pressure Head at Bottom of WaN: � ' Zero (see drawing --►)
Pressure Factor: :0:5 (reduces water pressure)
Full Zero
� 1' �O S
Vertical Point Load: '"; kips Horizontal Point Load: �kips
L—► Distance Behind Toe: �.�,;_ ._..' ft
Vertical Pressure on Backslope: 455.0 psf Horizontal Pressure on Wall: . �psf
Vertical Seismic Coefficient: C�9 Horizontal Seismic Coefficient: r��9
.� �a�.
Desired Factor of Safety: 1.3.5 Note: Factor of Safety is applied to tangent of Friction Angle.
� fl.O:..
Dip of Critical SurFace,a: Y57 degrees
Total Weight of Wedge,W: 27�5 kips
Total Water Force, U: ; 5;8 kips
Total.Vertical Surcharge Load,S,�: ! 62 5 kips Vertical Seismic Load, E�: 0 0 kips
Total Horizontal Surcharge Load,S,,: ; 0.0 kips Horizontal Seismic Load, E,,: r� O:U, kips
Closure Angle=90-(90-�Dmob)-a: ``25.1 degcees
s�I"
Horizontal Force Required, H: �,�, ��;5 6 kips/LF of wall
Inclination of Reinforcement: .�5:0 degrees
Include Vert. Component of Reinforcement? =:Yes
Force Required @ Inclination,T: �" y:�?��4�0 kips/LF of wall
. ,., ..,. ... . .. . . Copyright 05/17/2005 Schnabel Foundation Company
f • {�{/'o
_ Excavation Geometry .
30
' 20
��
� .
_ � 10 Ground Surface
� — —Critical SuAace
� - - - Soillnterface
� Water Table
0
-10 0 10
USE 8'x8'PATTERN FOR ROCK BOLTS
DLT 138kips,USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
sub rasie ft.minimum
21 1 22
13 2 18
5 3 13
Copyright 05/17/2005 Schnabel Foundation Company
� �5�50
SC�111a.be� STABILITY ANALYSIS 35' rock /.,22' earth
Foundation Company Vail Front Door 2-17-06<
South Wa{I Permanent Shoring
� � � - � .
__ �( [� - ; a p, ~ p�:e .
Total Height of Wall: 35 ft
Wall Batter(0=vertical}: 5.7 degrees
Inclination of Backslope: ;:0 degrees
.
' . �.:.: � �.r..4��.�.�.e� _ :
Friction Angle: 4..40 degrees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: ::,0 ft below Top of Wall �
Unit Weight-Layer 1: � �13Q pcf _
Unit Weight-Layer 2: =:, =160 pcf
Water Table Location: •�=35 ft above Bottom of Wall
Pressure Head at Bottom of Wall: F;Zero: (see drawing —►)
Press�re Factor: ,: ,. :: -0:5 (reduces water pressure)
....,r....
Full Zero
. .
-1���s..,�� ct
Vertical Point Load: ; : kips Horizontal Point Load: �kips
�—► Distance Behind Toe: �:; �, ,�:ft
Vertical Pressure on Backslope: �'351U: psf Horizontal Pressure on Wall: �psf
Vertical Seismic Coefficient: �9 Horizontal Seismic Coefficient: �9
Desired Factor of Safety: ;>:.1.:'35 Note: Factor of Safety is applied to tangent of Friction Angle.
����.
Dip of Critical Surface,a: °57;degrees
Total Weight of Wedge,W: -
, ,,:..:�.53:9 kips
Total Water Force, U: �11 �1 kips
Total Vertical Surcharge Load, S�: �67 5 kips Vertical Seismic Load, E�: ' �0� kips
Total Horizontal Surcharge Load,SH: �U Q kips Horizontal Seismic Load, EH: ,0 0 kips
Closure Angle=90-(90-�mob)-a�: =�25;1 degrees
,�,,, � ,
Horizonta! Force Required, H: ,��:{r fi3:6 kips/!.F of wafl
�,.
Inclination of Reinforcement: `95.0 degrees
Inc(ude Vert.Component of Reinforcement? Yes
Force Required @ Inclination,T: �� : ',�7,��:3 kips/LF ofwall
Copyright 05/17/2005 Schnabel Foundation Company
' I��So
Excavation Geometry
40
; :
` ` �.-__. � 30
� '
�
_ _ ._ _.� i 20
'�
' Ground Surface
_..._I � ' '
_.._..,......____. ; _---�--..s_�,..-------,.---.._._...._..._.. 10 — —Critical Surface
- - Soillnterface
` � Water Table
0
-10 0 10 20 30
USE 8'x8'PATTERN FOR ROCK BOLTS
DLT 137kips,USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
subgrade ft.minimum)
31 1 28
23 2 24
15 3 19
7 4 14
Copyright 05/17/2005 Schnabef Foundation Company
:
Schn�abel Calculation Sheets
FOUNDAT'[ON COMPANY
Project: Vail Front Door Contract No.• 07-3715
Location: Vail,CO. Sheet No.:�
Owner: VRDC Date: February 17,2006
By: CHB
Rev.By:JAF
South:Excavation Shoring: Tieback Block Desi n,80 ki load : � ~-
� 9 p - . _
Tieback anchor design: DLTN:= 80kips DLTfac�- DLTN•1.3 �ACI 318-OZ 9.2.2 eq.9-21oad factor H)
Wall design:
f�:= 4000psi fy:= 60ksi e U := 0.003 s t:= 0.004 (31 := 0.85 sqf�:= 63.246psi
(Beta 1 from ACI 318-02 10.2.7.3)
�bearing�— ��65 �shear�— 0�75 �tension�- 0.9
(Theta values from ACI 318-02 9.3.2.2b)
diameterhole�— �14mm
Minimum bearing plate size for tie to concrete interaction:
diameterhole 2 2
Areahole'— n'( 2 � Areahole - �5.821 in Xplate�- �•Sin
DLTN 2
e N=- Are N-36.199 in (ACI 318-0210.17.1)
� 9 RI'fc'�bearing 9
Areaplate'— Xplate2 Areaplate-56.25 in2 Areaplate—Areahole-40.429 inZ
earing plate dimensions: 7.5"x 7.5"
dshear'— �•�Sin (dsnear�s depth to reintorcement)
Block dimensions x:= SR
Factored earth pressure qfac�
Pfac:= DLTN•13 Pfac — I��ps 9fac�- Pf zC 9fac=4.161csf
X (ACI 318-02 9.2.2 eq.9-2 foad factor H)
The block is designed as an individual column footing supporting a sing/e tieback.
�
5������[�b�l Calculation Sheets
FovrmATtorr coNrnarrY
Project: Vail Front Door Contract Na.: 07-3715
Location: Vail,CO. Sheet No.: IaLSo
Owner: VRdC Date: February 17,2006
By: CHB
Rev.By:JAF
� .South�:Excava#ion Shorinq: Tieback Block Design 80 kip. load - �- - �
Block shear calculations: dshear-�•�Sin
Two-way shear for a factored column load:
b := 4•�xp + d � b =61 in 2 bo 2
o late shear o
Vul '– qfac' x – — Vu1 =97.282kips
4
V�p:= 4•sqf�•bo•dshear V�p= 1 I9.598 kips �ucp�– �shear'V�p �V�p= 89.699 kips
Depth is adequate for the factored shear Vu1 (�Vcp>Vu1).
One-way shear for a factored column load at distance dsnear from the centerline of the tieback:
Vu2:= qfac'[(2 – �2 te –dshear)�xJ Vu2 =32.0671dps
uc=- 2'Sgfc'�X'dshear� V� =58.8191dps �uc�– �shear'V� �V�=44.114kips
.
- �C���t1�,b��, Calculation Sheets
FOUNDATION COMPANY
Project: Vail Front Door Contract No.: 07-3715
Location: Vail,CO. Sheet No.: i9/so
Owner: VRDC Date: February 17,2006
Sy: CHB
Rev.By:JAF
.�. �:.South Ex�avatinn°Shorinq: Tieback Block Design 80 kip load � -
vva�� remrvrcemeni ca��uiaiivns:
2
x '�piate
2 — 2 )
Muh-= 9fac' 2 'x Muh=49.766kips•ft ,
A ._ Muh A = 1.638in2 area required by analysis
S �tension�fy'�dshear— lin) S
3•sqf� 2
Asminlv'— f •x•dshear `�'sminlv- 1.47in
Y
200•lb -x•d area required by ACI318-02 10.5.1
2 shear
m 2
Asmin2v'— f Asmin2v- 1.55 in .
Y
Asmin3v�— 133-As Asmin3v-2•179in2 area required by ACI318-02 10.5.3,which
superceedes 10.5.1 if it is less
Nobar'— 8 As6 �— -31in
2
Nobar'As6 -2-48in2 we wiil be providing 8#5 bars flanking the anchors each way
Id=38db per commentary in ACI 318-02 R12.2.for normal weight concrete,uncoated reinforcement,
No.6 or smaller bars.
Development Lenqth
X—Xplate
ldavail'— 2 idavail-26.25in
dbs:= 5 in 1dre9:= 38•dbs 1�.�=23.75 in (with 25"+available,the development length is sufficient)
8
.
Sc�ur�►a.bel Calculation Sheets
' FOLJNDATION COMPANY
Project: Vaii Front Door ' Contract No.: 07-3715
Location: Vail,CO. Sheet No.: 20
Owner: VRDC Date: February 17,2006
By: CHB
Rev. By:JAF
- . South Excavation Shorinq: Tieback Block Design 125 kip load
Tieback anchor design: DLTN:= 125kips DLTfac�- DLTN•13
(ACI 318-02 9.2.2 eq.9-2 load factor H)
Wall design:
f�:= 4000psi fY:= 64ksi s u:= 0.003 s t:= 0.004 �i 1 := 0.85 sqf�:= 63.246psi
� •— 0.65 � '— 0.75 �tension�— 0•9 (Beta 1 from ACI 318-02 10_2.7.3)
bearing•— shear=
(Theta values from ACI 318-02 9.3.2.2b)
diameterhole�— 114mm
Minimum bearing plate size for tie to conccete interaction:
rdiameterhole 2 2
Areahole'— ��I 2 � Areahole- 15.821 in ��ate�— 8•7Sin
�
DLTN 2
�re N�- �re N—56.561 in (nCl 3�8-02�0.�7.�)
9 p 1'fc'�bearing 9
Areap2ate'— Xplate Areap�ate—�6.563 in2 Areap�ate—Areahole—60.742 in2
earing plate dimensions: 8-3/4"x 8-3/4"
ashear�- 10.25in (dsnear�s depth to reinforcement)
Block dimensions x:= Sft
Factored earth pressure qfac�
Pfac:= DLTN•13 Pfac= 162.Skips 9fac'- pf2C qfac-6.Sksf
X (ACI 31&02 9.2.2 eq.9-2 load factor H)
The block is designed as an individual column footing supporting a single tieback.
� �ch�a.bel �alculation Sheets
FOUNDATION COMPANY
Project: Vaii Front Door Contract No.: 07-3715
Location: Vail,CO. SheetNo.: z�./5o
Owner: VRDC Date: February 17,2006
By: CHB
Rev.By:JAF
South Ezcava#ian Shorinq: Tieback Block Design 125 kip load �
Block shear calculations: dshear- 10.25in
Two-way shear for a factored column load:
ti .:= 4• +d b =76in b 2
o . �Xplate shear� o
Vul '— 9fac' X2—(�) Vul = 146.205 kips
4
ucp'' 4'Sgfc'bo'dshear V�P= 197.075 kips �V�p= �shear'V�P �V�P= 147.806 kips
Depth is adequate for the factored shear Vu1 (�Vcp>Vu1).
One-way shear for a factored column foad at distance dsnear from the centerline of the tieback:
Vu2 := 9fac'[C2 — �2 te —dshear)'X� Vu2=41.641 kips
V�:= 2•sqf�•�x•dshear� V�=77.793 kips �uc'— �shear'V� �V�=58.344 kips
SC�L.I�.b�l, Calculation Sheets
FOLJNDATTON COMI'ANY
Project: Vail Front Door Contract No.: 07-3715
Location: Vail,CO. Sheet No.: zL 5
Owner: VRDC Date: February 17.2006
By: CHB
Rev.By:JAF
South Excavation Shorinq: Tieback Block Design 125 kip load
Wall reinforcement calculations:
2
x xplate •
. \2 2 _
Muh'— qfac' •x MUh—74.1 kips•ft
2
A ._ Muh A = 1.78 in2 area required by analysis
S �tension'fy'�dshear— lin} s
3•sqf� 2
'°`sminlv�— f 'x•dshear Asminlv- 1.945in
Y
200•�b •x•d area required by ACI318-02 10.5.1
2 shear
�n 2
Asmin2v�- f `�smin2v-2.05 in
Y
Asmin3v�- 133-As �`smin3v-2-368in2 area required by ACI318-02 10.5.3,which
superceedes 10.5.1 if it is less
Nobar:= 8 As6 :_ .31in2
Nobar'�`s6-2'48 m2 We will be providing 8#5 bars flanking the anchors each way
Id=38db per commentary in AC!318-02 R12.2.for normal weight concrete,uncoated reinforcement,
No.6 or smaller bars.
Development lenc�th
X—Xplate
idavail'— 2 Idavait -25.625 in
db5:= g in tdreq:= 38-db5 Idreq-23.75 in (with 25"+available,the devetopment length is su�cient}
.
5cl�ur�►,abe� Calculation Sheets
FOIJNDATTON COMPANY
Project: Vait FroFlt Door Contract No.: 07-3715
Location: Vail,CO. Sheet No.: 2�L,�n,_
Owner: VRDC Date: February 17,2006
By: CHB
Rev. By:JAF
South Excavation Shorinq: Permanent facing shear calculations
Tieback anchor design: DLTN:= 125kips
Wall design:
f�:= 4000psi fy:= 60ksi su:= 0.003 st:= 0.004 (31 _= 0.85 sqf�:= 63.246psi
{Beta 1 from ACI 318-0210.2.7.3)_
�bearing�— 0.65 �shear�— 0�75 �tension� 0.9
(Theta values from ACI 31&02 9.3.2.2b)
diameterhole=— 114mm dshear'— 3.25in (dsnea�is depth to wall reinforcement
from tieback block reinforcement)
Block dimensions x:= Sft (block dimensions,5'x 5'square) A:= lOft (tieback load area dimension,10'x 10'
square)
Factored earth pressure q��:
Pfac:= DLTN•13 Pfac— 162.5 kips 4fac�— Pf 2 qfac- 1.625 ksf
A
Block shear calculations:
Two-way shear for a factored column load:
bo:= 4•�x+ dshear� bo =253 in b 2
Vul �- 4fac' A2—(�J Vul - 117.355 kips
4
V�p:= 4-sqfc�bo'dshear V�p=208.016 kips �ucp�- �shear"V�p �V�p= 156.012 kips
Depth is adequate for the factored shear Vui (�Vcp>Vu1).
One-way shear for a factored column load at distance dsnear from the centerline of the tieback:
Vu2:= 9fac�[(a —x —dshear)'A] Vu2=36.224kips
2 2
V�:= 2•sqf�•�A•dshear� V�=49.332kips �uc'— �shear'V� �V�=36.999kips
" Schnabel
FOUNDATION COMPANY ?��5 0
� Schnabel Foundation Company
Vail Front Door-Permanent South Wall
February 17,2006
_ ' �'��,�r�..:�e_ �� � . -
Enter the foltowing_variables:
Nofe:Enter 0 if not applicable
AASHTO Load Combination 1,4 or 7:(Table 4.3) r��
Nai!Spacing
Horizontal nail spacing:(ft) �
Vertical nail spacing:(ft) 5.
Facing Properties and Thickness:
Material:shotcrete or CIP concrete? Shotcrete
Shotcrete/concrete thickness: (in) ':7;°
Shotcrete/concrete wmpressive strength: (psi) '°:4500;;': '
Horizontal ReinforcemeM
Bar spacing: (in) =1:2 .,> aasyro:max spa���y=Ls'T,or 18 in.
B8f SIZ@#: (3-9� 4,':,,,_•4 Required length of lap splice(in)= 20.52
Yield stress:(ksi} 60._;� Aashro,161h Edition,A�tic%8.32.1.4,p.193
Non-contact!ap splices see Arficle 8.32.1.3
Vertical Reinforcement
Bar spacing: (in) .12• ,': aasHro:m�r.sPa�;ny=ts�T or te in.
B8�SIZe#: (3-9� 4.; "" Required tength of lap splice pn)= 20.52
Yield stress:(ksi) 60: �: aASHro,16th Edition,Art/c!e 8.32.1.4,p.193
Non-contact lap splices see Article 8.32.l.3
Bearing Plate Details
Bearing plate width:(in) ;�,2 �
Bearing plate thickness:(in) ;0.75 �
Yield Stress:(ksi) 36:. .•
Headed Stud Details(See Table F.3)
Note: Design assumes 4 studs per plate
Stud spacing(cc): (in) 9` �
Stud length(after weld): (in) :,4:25 :':
Diameter of stud body: (in) 1.; �
Diameter of stud head:(in) 2:5 {:�
Head thickness: (in) ,1;; °
Ultimate Stress:(ksi) �6Q'� :'
Drill Hole Diameter:(in) 3.5 P>
Permanent Facing
Copyright 2004 Schnabel Foundation Company
' Minimum and Maximum Reinforcement Ratio Check
AASHTO Requirements: 2 5��o
� ---►To Ensure Ductile Failure:
Minimum horizontal reinforcement ratio: (requirement waived per FHWA, DP 103,Sec6on 4.7.1,p. 106)
Maximum horizontat reinforcement ratio: �O�,tY13
Ma�mum verticaf reinforcement ratio: ��`�3�
Checking AASHTO maximum steel requirement...
OK
—►Shrinkage and Temperature Reinforcement:
Minimum reinforcement=0.125 in2 per foot,regardfess of wall thickness.
AASHTO,16th Edition,Article 8.20.f,p.187
Checking AASHTO minimum steel requirement for shrinkage and temperature...
OK
FHWA Requiremenis:
No additional requirements for permanent walls.
Flexural Strength Calculations .
Flexure Pressure Factor,C,,(Table 4.2)_ �
Horizontal Positive Moment Capacity(kip-ft/ft)= 3.37
Horizontal Negative Moment Capacity(kip-ft/ft)= 3.37
Vertical Positive Moment Capacity(kip-ft/ft)= 3.37
Vertical Negative Moment Capaaty(kip-fUft)= 3.37
Nom.Nail Head Strength for Flexure,Tfi(klpS)= 53.91 "Both vertical and horizontal moment capacities govem.
Allowable Nail Head Load for Flexure,Tf(kips)_ ��;: _= CONTROLS
"See Table 4.4
Punching Shear Calculation
Internal Punching Shear Strength,V„(kips)= 59:01 "Group pullout of studs govems.
Do you wish to consider soil reaction contribution to punching capacity? �Yes�:
Shear Pressure Factor,C5, (Table 4.2)_ �
Nominal Punching Shear Strength,T�,(kips)= 63.88
Allowable Nail Head Load for Punching,Tf(kips)_
"*See Table 4.4
Headed Studs Tensile Strength Calculation
Nominal Headed Stud Tensile Strength,Tfi, (kips)= 188.50
Allowable Nail Head Load for Tension,T�(kips)_ ;;�(2�6:�L9'�
Empirical Minimum Allowable Nail Head Service Load Check
Enter the following variables:
Empiricat coefficient F: (0.3-0.7,use 0.5) -.0:5;: ;°
Active earth pressure coefficient Ka:' 0:35 "
Soil Unit Weight:(pcfl 1,15;' ';_
Wall Height: (ft} _:65'= `:;
'If Ka is not known,enter Ka=0 above and
estimate active load Pa:(kips/ft of walf) �
Esfimated Nail Head Service Load(kips)_ ,_. �,�
Facing design exceeds estimated service load requirements. No revision required.
Permanent Facing
Copyright 2004 Schnabel FoundaUon Comparry
r
Schna�iel Z �5°
FOUNDATION COMPANY
Schnabel Foundation Company
Vail Front Door-Pennanent South Wall
� February 17,2006
�� ''e 17es:i' =e�
FHWA requires that the upper cantilever portion of soil nail wall facings be checked for structural adequacy.
This check is required because the upper cantilever is unable to distribute load by soil arching to adjacent spans.
Permanent facings must also be checked for serviceability.
IMPORTANT: Do you wish to calculate values corresponding to.the
Temporary Facing or Permanent Facing worksheet? �c�.'��Pe�nane�►t;� :r:
Enter the following variables:
Uppercantileverspan: (ft) ;�a�:�'�2?�
Active earth pressure coefficient ICa:' ;.;Tf; ;;; ;�>�
Soil unitweight:(pcfl �:�130:;��
Surcharge load:(ps� �20QOr�
'If Ka is not known:
1.EnCer Ka=0 above
2. Estimate active load Pa: (kips/ft of wall) �r�:� � �
3. Enter point of application:(ft above the nail head) r��"��
Shear Capacity
Nominal shear strength of.cantilever:(kipslft) 5.63
Allowable shear strength of cantilever:(kips/ft)
Estimated service shear: (kipslft) Shear capacity OK. No revision required.
Moment Capacity
Nominal moment capacity of cantilever:(kip-fUft) 3.37
Allowable moment capacity of cantilever: (kip-ft/ft)
Estimated service moment:(kip-ff/ft) Moment capacity OK. No revision required.
Servieeability Check
Service steel stress limit:(ksi) �
Service steel stress:(ksi) Seviceability check OK. No revision required.
. Upper Cantilever
Copyright 2004 Schna6ef Foundation Company
��������,��� Caiculation Sheets
Fa�1�IJA'ITQI\ CQ1�4?ANX
Contract No.:07-3715
Pro'ect: Vaii Front Door Sheet No:: 2�f 60
1 Date: February 17,2006
Location: Vait,CO. By: CHB
Owner: VRDC Rev.By:JAF
South Tunnel Shorinq
BEDROCK EXCAVATION:
For excavations in bedrock the following design parameters were used:
Allowable bedrock/grout adhesion: 100 psi
Diameter of drill hole: 3-3/4" '
Rock bolt angle(from horizontal) 15 degrees
Phi of bedrock: 40 degrees
Surcharge pressure: 2 ksf
Surcharge under footings: 20 ksf
From the above parameters the minimum required rock bolt length is calculated using the
equation below.The equation gives the distance required to reach the critical failure wedge(see
attached sheets)plus the required bond length for any given height of rock excavation.This
equation is provided because the actual depth to bedrock is currently estimated and in no situation
will rock bolts be installed that are shorter than this equation allows.
Minimutn nail length(ft.)=0.5727 x Height above subgrade+9.903
The permanent facing will consist of a 6-1/2"thick layer of 4000 p.s.i. shotcrete with 6 x 6-W2.9
x W2.9 welded wire mesh.The rock bolt heads will have a 8"x 8"x 7/8"thick plate with four
3/4"�d x 5"shear studs spaced 6"apart.The plate thickness includes 1/8"of sacrificial steel as
corrosion protection.
The rock bolts will be installed such that the upper row of bolts is no deeper than 4' below the top
of bedrock.The bolts will be spaced evenly on an 8'x S' grid pattern with no more than 64
square feet per bolt.
SOIL EXCAVATION
The total depth of excavation in soil along the permanent South Tunnel Wall(to the intersection
with the main south excavation wall)is not expected to exceed 27'.Due to uncertainty in the
bedrock elevation however,the shoring along the South Tunnel wall that is in soil will be
installed with the expectarion that bedrock is below subgrade.As such the top-down installation
(and this design)will assume a full height of soil. Where bedrock is encountered before subgrade,
the shoring will continue as described above(BEDROCK EXCAVATIOl�.Attached are the
design sheets for permanent soil nailing of a 27'high cut including a permanent facing.
,
Ze`
50
� SC�lrlabe� STABILITY ANALYSIS 20' Excavation
Foundation Comp�n3� Vail Front Door 2-17-06
Permanent South Tunnel Shoring
:� -� ,. � _.,
- . :�t �,�c����.,�...; '..e; ;.��,�
Total Height of WaIL 20 ft
Walf Batter(0 =vertical); 0 degrees
Inclination of Backslope: 0 degrees
_ . . _ . . .. „ .
� -
,
.�°- �
�
n ,._._ r.��,. u.. �rope;res
Friction Angle: ` ,40 degrees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: 0 ft below Top of Wail �
Unit Weight-Layer 1: 0 pcf
Unit Weight-Layer 2: 160 pcf .
Water Table Location: 20 ft above Bottom of Wall
Pressure Head at Bottom of Wall: ' Zero (see drawing --►}
Pressure Factor. ; 0.5 (reduces water pressure)
Full Zero
�` �:.���5 `�'
Vertical Point Load: kips Horizontal Point Load: � �kips
�--► Distance Behind Tc^: _ , ft
Vertical Pressure on Backslope: ` -2000 psf Horizontal Fressure on Wall: �psf
Vertical Seismic Coe�cient_ O9 Horizontal Seismic Coefficient: �g
. , e�,:
Desired Factor of Safety: ': .. 1.35 Note: Factor of Safety is applied to tangent of Friction Angle.
io� -
Dip of Critical Surface,a: �,'.61. degrees
Total Weight of Wedge,W: " 17:7 kips
Total Water Force, U: " 3:6 kips
Total Vertical Surcharge Load,S,,: .::: 22;2 kips Verticat Seismic Load, E�: 0:0 kips
Total Horizontal Surcharge Load, SH: _: 0:0 kips Horizontal Seismic Load, EH: � �U,U kips
Closure Angle=90-(90-�mob)-a: ;29::1 degrees
, . _
w h t.w
es `
-:r. �'�`yz:
Horizontal Force Required, H: � r�� kips/LF of wall
Inclination of Reinforcement: "::15:0 degrees
Include Ve�t. Component of Reinforcement? Yes
Force Required @ Inclination,T: ,��`�t29;,7 kips/LF of wall
Copyright 05/17/2005 Schnabel Foundation Company
.
, Excavation Geometry Z�'�5o
ao
..---._.._....-.--..---_______-__._....._._.__...----.___._.._.........--?---._......____._.... 30
_......_...------- ' ........----- 20
�;
/ Ground Surface
-----.... _. ._ ..
._.. _____---. . _..___ . ;.... . _.........__.._ 10 — —CriUcal Surface
� - � Soillnterface
/ Water Table
0
-10 0 10 20 30 40
USE 8'X8'PATTERN F4R ROCK BOLTS
DLT 95kips,USE 1-1/4"150ksi BAR
Depth to Row Length of rock boit �
sub rade ft.minimum)
16 1 20
8 2 15
Copyright 05/17/2005 Schnabel Foundation Company
.
, 3 0/5 0
� Schnabel sTABILITY ANALYSIS 29' Excavation
Foundation Company Vaii Front Door 2-17-06
Permanent South Tunnel Shoring
.. .. . ,�
_ .
.
°�` � `111�a1�Ex�a`��on���,o�e
s: , . -
, ��
.: . -....�_,-.;�,._u_,.. � _ . .
Total Height of VNall: `29 ft
Wall Batter(0=vertical): 0 degrees
Inclination of Backslope: ' ' '0 degrees
� �� . _ , r
_ . .
� SOI�������.S' ..
.,.�.....
Friction Angle: �.�4.0 degrees
Dip of Critical SurFace: Search
Depth to Bottom of Layer 1: 0 ft below Top of Wall •
Unit Weight-Layer 1: � `0 pcf
Unit Weight-Layer 2: '�160 pcf
.,'���� *`
Water Table Location: .�29 ft above Bottom of Wall
Pressure Head at Bottom of Walk • ;Zero (see drawing --►}
Pressure Factor. . ;=0.5 (reduces water pressure)
Full Zero
,�.�#.�" ��9�.�$��s�ti I�o'�d.
Vertical Point Load: `.' kips Horizontal Point Load: �kips
�—► Distance Behind Toe: _, ` ..,,' ft
Vertical Pressure on Backslope: ° �2000' psf Horizontal Pressure on Wall: C�psf
Vertical Seismic Coe�cient: O9 Horizontal Seismic Coefficient: C�9
� �._ . . ..; ,
: E�.. ��'
Desired Factor of Safety: ,;._,1:35 Note: Factor of Safety is applied to tangent of Friction Angle.
„,
_- �
.,- _ ;�..,ta��o
:r��;., �
Dip of Criticat SurFace,a: ,_ .;:,._.;61 degrees
Total Weight of Wedge,W: ''':37.3 kips
Total WaterForce, U: .; 7.5 kips
Total Vertical Surcharge Load,S�: � 32,1. kips Vertical Seismic Load, E�: �O:U, kips
Total Horizontal Surcharge Load, S,�: � 0;0 kips Horizontal Seismic Load, EH: Q.0 kips
Closure Angle=90-(90-�mob)-a: � ;`;_29.1 degrees
- - _ _ . .
._ . ._. �t�.:
Horizontal Force Required,H: '" ;��;;.':q,�'�2 kips/LF of wall
;
Inclination of Reinforcement: ; . 15:0 degrees
fnclude Vert. Component of Reinforcement? ' ` _Yes
Force Required @ Inclination,T: �'�;�v2;6: kips/LF of wall
Copyright 05/17l2005 Schnabel Foundation Company
.
, �'/
5�
, Excavation Geometry
40
_._ _ __....... _._ _ _:. . 30
i /
..---._. -----1-__---..--._.___._..___...:_.__...----...------ 20
/
� 's Ground Surface
_.. ..._. __ ' ; + 10 — —CriticatSurface
� � - Soillnterface
� Water Table
0
-10 0 10 20 30 40
USE 8'X8'PATTERN FOR ROCK BOLTS
DLT 116kips, USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
subgrade ft.minimum)
25 1 25
� 17 2 20
9 3 16
Copyright 05/17/2005 Schnabel Foundation Company
�
.
,��/5Q
� Schnabel STABILITY ANALYSIS 34' Excavation
Foundation Comp:tny Uail Front Door 2-17-06
Permanent South Tunnel Shoring
��
� _.- �. .:. � � Vya(�� c-� : � G�om �
,3 s a
Total Height of Wall: 34 ft
Wall Batter(0=verticaQ: 0 degrees
Inclination of Backslope: 0 degrees
� , � _
�. �.- . �.- �
..,�'�o��'�„�•,P�� ��.�� . � . . � .
Friction Angle: ` 40 deg�ees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: 0 ft below Top of Wall •
Unit Weight-Layer 1: 0 pcf
Unit Weight-Layer 2: 160 pcf
R ' ^� �(y}� �
�.. .... . �.. .. . . � . - .. . . �.
��'+.�"�?' � yi:1G��i 1 y�;��3CF1}�.EA,�.
Water Table Location: °34 ft above Bottom of Wall
Pressure Head at Bottom of Wall: - :: Zero (see drawing --►)
Pressure Factor. �0:5 (reduces water pressure)
Full Zero
;.�. r9n: e�s :��
Vertical Point Load: kips Horizontal Point Load: �kips
�—► Distance Behind Toe: ` ft
Vertical Pressure on Backslope: 2000 psf Horizontal Pressure on Wall: �psf
Vertical Seismic Coefficient: O9 Horizontal Seismic Coe�cient: �9
_ .
� _.. p ,
Desired Factor of Safety: = 1.35 Note:Factor of Safety is applied to tangent of Friction Angte.
�`fCll��
Dip of Critical Surface,a: 61 degrees
Total Weight of Wedge,W: ;51.3 kips
Total Water Force, U: 10;3 kips
Total Vertical Surcharge Load, S�: 37 7 kips Vertical Seismic Load, E,,: 0.0 kips
Total Horizontal Surcharge Load, Sr�: `. 0 Q kips Horizontal Seismic Load, EH: : �0.0 kips
Closure Angle=90-(90-�mob)-a ::29;1 degrees
�e. 3 - -
Horizontal Force Re uired, H: ' ��°`�� '�5;$, ki s/LF of wall
q -'•�`.�.�",r�`��. P
Inclination of Reinforcement: `-; 15.0 degrees
Include Vert. Component of Reinforcement? Yes
Force Required @ Inclination,T: ����'�67 9 kips/LF of wall
Copyright 05l17/2005 Schnabel Foundation Company
r
Excavation Geometry 33/�o
40
_. ___. _ s. _ ./ ; ',... _ gp
i /
..___ _.. � ._.__._. __.....- - --____- 2p
�
� i
i Ground Surface
_--___ _._ __._, _:_ _.._... : _.......__.... 10 � —Critical Surface
: - - Soillnierface
� Water Table
0 �
-10 0 10 20 30 40
USE 8'X8'PATTERN FOR ROC.K BOLTS
DLT 128kips, USE 1-3/8"150ksi BAR
Depth to Row Length of rock bolt
sub rade (ft. minimum
30 1 28
22 2 23
14 3 18
6 4 14
Copyright 05I17/2005 Schnabel Founda6on Company
.
'iy�S o
. �Chnabel STABILITY ANALYSIS 7' Excavation
Foundation Company Vail Front Door 2-17-06
Below footing rock reinforcement
_ . � .�
. 1N�t��a atrark"� .: > .:.�.
Total Height of Wall: :�7 ft
Wail Batter(0=vertical): 0 degrees
Inclination of Backslope: 0 degrees
: ��. �_� � __
SO OC ,�I.e
Friction Angle: 4.0. degrees
Dip of Critical Surface: Search
Depth to Bottom of Layer 1: 0 ft below Top of Wall .
Unit Weight-Layer 1: ' 0 pcf
Unit Weight-Layer 2: 160 pcf
Water Table Location: ;7 ft above Botfiom of Wall
Pressure Head at Bottom of WaIL ,:,...:>: Zero (see drawing --►)
Pressure Factor: ',.:, 0:5 (reduces water pressure)
Fuil Zero
��u ,�. s
Vertical Point Load: .,: kips Horizontal Point Load: �!_ = lkips
L—► Distance Behind Toe: _ `'ft
Vertical Pressure on BacksloPe: = 200Q0 psf Horizontal Pressure on Wall: �psf
Vertical Seismic Coefficient: �9 Horizontal Seismic Coefficient: �9
� _. :_.
, �
Desired Factor of Safety: ; •1.35 Note: Factor of Safety is applied to tangent of Friction Angle.
�'. - �� ;.,�
Dip of Critical Surface, a: �61'degrees
Total Weight of Wedge,W: ' �2.2 kips
Total Water Force, U: 0 4 kips
Total Vertical Surcharge Load, S�: k;;' 77:6 kips Vertical Seismic Load, E�: .� :: O;Q kips
Total Horizontal Surcharge Load, SH: � �' O.Q kips Horizontal Seismic Load, EH: �„�` ��10 kips
Closure Angle=90-(90-�mob)-a: _. . :_29:1;degrees
Horizontaf Force Required, H: ;:����:�q4;;�;kips/LF of wall
Inclination of Reinforcement: 1.5:-0 degrees
Include Vert. Component of Reinforcement? `�X.es
Force Required @ Inclination,T: ��54=4 kips/LF of wall
Copyright 05/17/2005 Schnabel Foundation Company
'
35��0
, Excavation Geometry
,o
�
�
�
�
/ Ground Surface
— —Criticai Surface
� - - Soil interface •
/ Water Table
0
-10 0 10
PLACE NAIL 2'BELOW EACH FOOTING @ 3'O.C.
DLT 139kips, USE 1-3-8'' 150ksi BAR(Length 15')
Copyright 05/17/2005 Schnabel Foundation Company
�
3���o
"� � M�� ►• s
Date: 02-13-2006 �nall�ln 3.1� File- UFD 27ft gerwanent
M i n i mum Fact a r of Saf et y = 1. 31
30.$ ft Behind 41a11 Crest
At wall Toe
LEGEHD:
H= 2'T.0 ft �-z- , PS= 12.6 Kips
Q � F�.L:�1-'�I:��;��� �
FY= 41.3 Hsi
�-�� , Sh= 5.0 f t
J
�`�'��.ti,� S�= 5.0 f t
~~7/� GAM PHI COH SIG
�--„ pcf deg psf psi
�'�---.�.-' 1 130_0 34 0 17.0
���
�'.
��-v�M1
Scale = 16 ft �r�!� Surcharge
i 3'�-�
File: VFD 27ft permanent So Page - 1
***+*************************,r***********ar*******,r*
' * CALIFORNIA DEPARTMENT OF TRANSPORTATION *
* ENGINEERING SERVICE CENTER *
* DIVISION OF MATERIALS AI3D FOUNDATIONS *
, , * Office of Roadway Geotechnical Engineering *
* Date: 02-13-2006 Time: 06:50:10 *
****�*******�*************************�********�***
Project Identification - Vail Front Door 27' Permanent
--------- WALL GEOMETRY ---------
Ver.tical Wall Height = 27.6 ft
Wall Batter = 5.7 degree
Angle Length
(Deg) (Feetj
First Slope from Wallcrest. = 0.0 120.0
Second Slope from ist slope. = 0.0 0.0
Third Slope from 2nd slope. = 0.0 0.0
Fourth Slope from 3rd slope. = 0.0 0.6 •
Fifth Slope from 3rd slope. = O.D 0.0
Sixth Slope from 3rd slope. = 0.0 0.0
Seventh Slope Angle. = 0.0
--------- SLOPE BELOW THE WALL ---------
There is NO SLOPE BELOW THE TOE of the wall
--------- SURCHARGE ---------
THE SURCHARGES IMPOSED ON THE SYSTEM ARE:
Begin Surcharge - Distance from toe = 3.0 ft
End Surcharge - Distance from toe = 27.0 ft
Loading Intensity - Begin = 2.0 psf/ft
Loading Intensity - End = 2.0 psf/ft
--------- OPTION #1 ---------
Factored Punching shear, Bond & Yield Stress are used.
--------- SOIL PAR7IMETERS ---------
Unit Friction Cohesion Bond* Coordinates of Boundary
Soil Weight Angle Intercept Stress XS1 YS1 XS2 YS2
Layer (Pcf) (Degree) (Psf) (Psi) (ft) (ft} (ft) (ft)
1 130.0 34.0 0.0 17.0 0.0 0.0 0.0 0.0
* Bond Stress also depends on BSF Factor in Option #5 when enabled.
� 3��5°
File: VFD 27ft permanent Page - 2
--------- WATER SURFACE ---------
NO Water Table defined for this problem.
--------- SEARCH LIMIT ---------
The Search Limit is from 2_6 to 54.0 ft
You have chosen NOT TO LIMIT the search of failure planes
to specific nodes.
--------- REINFORCEMENT PARAMETERS ---------
Number of Reinforcement Levels = 5
Horizontal Spacing = 5.0 ft
Yield Stress of Reinforcement = 41.3 ksi •
Diameter of Grouted Hole = 3.0 in
Punching Shear = 12.0 kips
---------- (Varying Reinforcement Parameters) ---------
Vertical Bar
Level Length Inclination Spacing Diameter Bond Stress
(ft) (degrees) (ft) (in) Factor
1 27.0 15.0 2.0 0.88 1.00
2 25.0 15.0' 5.0 0.88 1.OQ
3 20_0 15.0 5.0 0.75 1.00
4 15.0 15.0 5.0 0.75 1.00
5 15_0 15.0 5.0 0.75 1.00
,� '��s�
File: VFD 27ft permanent Page - 3
MINIMUM DISTANCE LOWER FAILIIRE UPPER FAILURE
� SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
Toe 1_327 7.8 55.9 9.6 82.9 19.0
Reinf. Stress at Level 1 = 36.236 Ksi (Punching Shear controls. .)
2 = 35.845 ksi (Punching Shear controls. .)
3 = 41.250 Ksi (Yield Stress controls.)
4 = 41.250 Ksi (Yield Stress controls.}
5 = 38.157 ksi {Punching Shear controls. .}
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft? (deg) (ft)
NODE 2
1.327 13.0 46.2 11.2 74.7 19.6 .
Reinf. Stress at Level 1 = 41.250 Ksi (Yield Stress controls.)
2 = 41.250 Ksi (Yield Stress controls.)
3 = 41.250 Ksi (Yield Stress controls.}
4 = 34.656 Ksi (Pullout controls. . .)
5 = 41.250 Ksi (Yield Stress controls.)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 3
1.361 18.1 46.2 21.7 71.5 11.4
Reinf. Stress at Level 1 = 41.005 Ksi (Pullout controls. . .}
2 = 38.181 Ksi (Pullout controls. . .)
3 = 41.250 Ksi (Yield Stress controls.)
4 = 36.438 Ksi (Pullout controls. . .)
5 = 41.250 Ksi (Yield Stress controls.)
y°�s
0
� File: VFD 27ft permanent Page - 4
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
` SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft? (deg) (ft) (deg) (ft)
NODE 4
1_329 23.2 37.8 17.6 60.2 18.7
Reinf. Stress at Level 1 = 30.160 Ksi (Pullout controls. . .)
2 = 30.558 Ksi (Pullout controls. . .)
3 = 29.078 Ksi (Pullout controls. . .)
4 = 25.434 Ksi (Pullout controls. . .)
5 = 41.250 Ksi (Yield Stress controls.)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 5 .
1.314 28.3 32.4 20.1 55.0 19.8
Reinf. Stress at Level 1 = 18.171 Ksi (Pullout controls. . .j
2 = 20.140 Ksi (Pullout controls. . .}
3 = 17.037 Ksi (Pullout controls. . .)
4 = 18.543 Ksi (Pullout controls. _ . )
5 = 41.250 Ksi (Yield Stress controls.)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft} (deg) (ft) (deg) (ft)
NODE 6
1.308 33.5 22.0 7.2 42.2 36.2
Reinf. Stress at Level 1 = 12.787 Ksi (Pullout controls. . .)
2 = 19.199 Ksi (Pullout controls. . _)
3 = 21.805 Ksi (PuZlout controls. . .)
4 = 17.477 Ksi (Pullout controls. . .)
5 = 34.9�9 Ksi (Pullout controls. . .)
' 4��50
�
File: VFD 27ft permanent Page _ 5
.
MINIMUM DISTA�ICE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLAi�IE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 7
1.320 38.6 19.3 8_2 38.2 39.3
Reinf. Stress at Level 1 = 3.435 Ksi (Pullout controls. . .}
2 = 11.501 Ksi (Pullout controls. . .)
3 = 13.576 Ksi (Pullout controls. . .)
4 = 11.498 Ksi (Pullout controls. . . )
5 = 31.180 Ksi (Pullout controls. . _)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft} (deg) (ft) (deg) (ft}
NODE 8
1.367 43.7 17.2 9_2 34.8 42.6
Reinf. Stress at Level 1 = 0.000 Ksi
2 = 4.305 Ksi (Pullout controls. . .)
3 = 5.885 Ksi (Pullout controls. . .)
4 = 5.910 Ksi (Pullout controls. . .)
5 = 27.695 Ksi (Pullout controls. . .)
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) {deg) (ft) (deg} (ft)
NODE 9
1_448 48.9 28.9 55.8 89.9 0.0
Reinf. Stress at Level 1 = 0.000 Ksi
2 = 3.692 Ksi (Pullout controls. . .)
3 = 9.209 Ksi (Pullout controls. . . }
4 = 13.393 Ksi (Pullout controls. . .)
5 = 39.336 Ksi (Pullout controls. . . )
, `'z/54
' File: VFD 27ft permanent page _ 6
MINIMUM DISTANCE LOWER FAILURE UPPER FAILURE
` SAFETY BEHIND PLANE PLANE
FACTOR WALL TOE ANGLE LENGTH ANGLE LENGTH
(ft) (deg} (ft) (c3eg) (ft)
NODE10
1.524 54.0 26.6 60.4 89.9 0.0
Reinf. Stress at Level 1 = 0.000 Ksi
2 = 0.000 Ksi
3 = 3.428 Ksi (Pullout controls. . .}
4 = 9.538 Ksi (Pullout controls. . .)
S = 37.409 Ksi (Pullout controls. . .)
********************************************************************
* For Factor of Safety = 1.0 *
* Maximum Average Reinforcement Working Force: *
* 12.991 Kips/level *
***********************************�********************************
� Schnabel `''is�
FOUNDATION COMPANY
' Schnabel Foundation Company
Vaii Front Door-Tunnel 27'Permanent
February 17,2006
� e _a :
Enter the following variables:
Note:Enter 0 if not applicable
AASHTO Load Combination 1,4 or 7:(Table 4.3) 1:;` �i
Nai!Spacing
Horizontal nail spacing: (ft) 5; �
Vertical nai!spacing: (ft) �,�5���
Facing Properties and Thickness:
Material:shotcrete or CIP concrete? 51ioCGtete
Shotcrete/concrete thickness:(in) ,�8;�
Shotcrete/concrete compressive strength:(ps) :";;;'4500��
Horizontal Reinforcement
Bar spacing: (in) �, .��:��� �
B8f SiZB#:{$-9) °��" 4;;;?;t Required length oflap splice(in)= 20.52
Yield stress:(ksi) -�, $Q:;� AASHTO,16th Edition,Arficle 8.32.1.4,p.193
Non-confac!lap splices see Article 8.32:i.3
Vertical Reinforcement
Bar spacing: (in) �;�::12�
Bar size#:(3-9) �_'`g��4� Reqoired length of lap spllce(in)= 20.52
Yield stress:(ksi) :;��6Q;� AASHTO,161h Edltion,Article 8.32.1.4,p.193
Non-contact!ap spllces see A►ticle 8.32.1.3
Bearing Plate Details
Bearing plate width:(in) ���,- �
�.�:�:.9:.}
Bearing plate thickness:(in) :x��Q�7;: °�
�.z,s�..
Yield S#ress:{ksi} >ri;�36;�'�
Headed Stud Details(See Table F.3)
Note: Design assumes 4 studs per plate
Stud spacing(cc):(in) 7r6:5����
Stud length(after weld):(in) :5�=�;^,5��;
Diameter of stud body:(in) :;:;�0:�75��
Diameter of stud head:(in) ;�fi�-1z25:�
Head thickness:(in) �,�U 3i2��
Ultimate Stress:(ksi) �`�:��`��0���
Drill Hole Diameter:(in) ;3=�°3:5:`-`�-
Permanent Facing
Copyright 2004 Schnabel Foundation Company
s Minimum and Maximum Reinforcement Ratio Check
4K�5o
AASHTO IZequirements:
� —�To Ensure Ductile Faiture:
Minimum horizontal reinforcement ratio: (requirement waived per FHWA, DP 103,Section 4.7.1,p. 106)
Maximum horizontal reinforcement ratio: ����'
Maximum vertical reinforcement ratio: 02�:�
Checking MSHTO maximum steel requirement...
OK
�Shrinkage and Temperature Reinforcement:
Minimum reinforcement=0.125 in2 per foot, regardless of wall thickness.
AASHT0,16th Edition,Article 8.20.1,p.187
Ghecking AASHTO minimum steel requirement for shrinkage and temperature...
OK
FHWA Requirements:
No additional requirements for permanent walls.
Flexural Strength Calculations
Flexure Pressure Factor, C�,(Table 42)_ �1
Horizontal Positive Moment Capacity(kip-ft/ft)= 3.87
Horizontal Negative Moment Capacity(kip-fF/ft)= 3.87
Vertical Positive Moment Capacity(kip-ftlft)= 3.87
Vertical Negative Moment Capaaty(kip-ft/ft)= 3.87
Nom. Nail Head Strength for Flexure,T��(klpS)= 61.91 "Both vertical and horizontal moment capacities govern.
A(lowable Nail Head Load for Flexure,T�(kips)_ _= CONTROLS
"'See Table 4.4
Punching Shear Calculation
Internal Punching Shear Strength,V�(kips)= 59.38 "Group pulloutofstudsgovems.
Do you wish to consider soit reaction contribution to punching capacityl ;�Yes";�
Shear Pressure Factor,C5, (Table 4.2)_ �
Nominal Punching Shear Strength,T�,(kips)= 63.72
Allowable Nail Head Load for Punching,T,(kips)_
"See Table 4.4
Headed Studs Tensile 5trength Calculation
Nominal Headed 5tud Tensile Strength,Ty,,(kips)= 106.03
Allowable Nail Head Load for Tension,T�(kips)_ _ ��
Empirical Minimum Allowable Nail Head Service Load Check
Enter the following variables:
Empirical coe�cient F:(0.3-OJ,use 0.5) Q;S��,�
Active earth pressure coe�cient Ka:' ,0 35�';
Soil Unit Weight:(pc� �,�115'�?'
�,,,;�.
Wall Height:(ft) ,�;�65�;;,�,:.
*If Ka is not known,enter Ka=0 above and
estimate active load Pa:{kipslft oE wall) �
Estimated Nail Head Service Load(kips)_
Facing design exceeds estimated ser�ice load requirements. No revision required.
Permanent Facing
Copyright 2004 Schnabel Foundatlon Company .
f
Schnabel . "5�s°
•
FOUNDATION COMPANY
Schnabel Foundation Company
Vail Front Door-Tunnel 27'Permanent
February 17,2006
. ay P���a�'�ile el��Des`�.ic�����
FHWA requires that the upper cantilever portion of soil nail wall facings be checked for structuraf adequacy.
This check is required because the upper cantilever is unable to distribute load by soil arching to adjacent spans.
Permanent facings must also be checked for serviceability.
IMPORTANT: Do you wish to calculate values corresponding to the
Temporary Facing or Permanent Facing worksheet? . -�:�;Permanent. ;�:'
Enter the following variables:
Upper cantilever span:(ft) ; 2���
Active ea�th pressure coefficient Ka:' ,�;
Soil unit weight:(pc� 130 -�:
Surcharge load:(ps� ;:2ppp � '
'If Ka is nOt knOwn:
1.Enter Ka=0 above _
2.Estimate active load Pa:(kips/ft of wall)
3.Enter point of application:(ft above the nail head) ; ��
Shear Capacity
Nominal shear strength of cantilever: (kips/ft) 6.44
Allowable shear strength of cantilever.(kipstft)
Estimated service shear: (kips/ft) Shear capacity OK. No revision required.
Moment Capacity
Nominal moment capacity of cantilever:(kip-ft/ft) 3.87
Allowable moment capacity of cantilever: (kip-ft/ft) �
Estimated service moment: (kip-ft/ft) ;��1�'�4-�w� Moment capacity OK. No revision required.
Serviceability Check
Service stee!stress limit:(ksi) �g
Service steel stress:(ksi) ,,;"- Seviceability check OK. No revision required.
Upper Cantifever
Copyright 2004 Schnabel Foundation Company
i,
t
�,�, �����`���1 Calculation Sheets
FOCJI�FDATTON CQA4I'.�5.i\'�,'
Project:.Vaii Front Door Contract No.: 07-3715
Location:Vail,CO. Sheet No.• 30
Owner: VRDC Date: Feb. 17,2006
Generai Contractor: Hyder Construction, Inc.
LOADING CONDfTIONS
— HINGED SUFPQRT.I�SSUMED AT �H BRACE OR 71EBACK. EXCEf''f T�P TIEFi
— HINGED SUPPOR7' ASSUMED A7 SU6GRADE
— SYSFEId IS FREE—DRAlNING {NO HYDROSTATIC PRESSURE)
— LOADING DIA6RAA�1 INCLUDES SURCHAF2GE FOR TRAFFlC AND NORMAL CON5TRUCTIOP! LOADS
(HEAVY LOADS SUCH AS CRANES NOT INCLUDED)
— WHERE APPLICAHLE, UP TO 337: REDUC7lON MAY BE TAKEN IN SOLDIER BEAM .MdMENTS
PER: FpUNDATION ENGINEERING; PECK, �
NANSON da THORNBURN; 1974; pp — 453-463 �
— ALL ANCHORS TO BE LOCATED BEHINO FAILURE PLANE A5 FOLLOWS
.\ ..►� �. ,� ,�
UNBONDED �
LENGf}i �
/ ANCHOR LENGTH BEYOND
FNLURE PLANE
/
/
�
/
/
/
/ 60'
/
'� .���` � /,�
— VALUES SHOWN IN THE CaLCUtATIONS ARE TAKEN FROM.A COA�IPUTER PRINTOlti
— ONLY THE CRfTICAL MOMENT IS SHOWN IN THE CALCUTATIONS
— ALLOWABLE BENDIt3G SiRESS FOR STEEL = D.66Fy 51NCE. FIANGES ARE FULLY
SUPPORTED IN THE PlANE OF BENDING
�
♦
�������e� Ca�culation Sheets
Fov�vnAnoN cotim.��
Project: Vail Front Door Contract No.: 07-3715
Location:Vaii,CO. Sheet No.: 43 So
Owner. VRDC Date: Feb. 17,2006
General Contractor: Hyder Construction,Inc.
EXISTING GRADE (TYP.)
.2H
!i 1
H = HEIGttT OF SOIL IN FEET
H1 = DEPTH TO TIEBACK IN FEET
H2 = DEPTH FROA1 TIEBACK TO SUBGRADE IN FEET
Mt Bt = HORIZONTAL TiEBACK LOAD IN KIPS/FT
g� 1 Mt = 50LDIER BEAM MOMENT AT TIEBACK 1N K—FT�FT
j MM1 = MAXIMUbi S(iLDIER BEAM MOItENT BETWEEN
� TIEBACK AND SUHGRADE IN K-FT/FT
MMt :6N
� H
H2
.2N OTTOAi OF EXCAYATIDN
LaAD INTENSITY INCUJUES SURCHARGE DUE TO
P=.Q25H NORMAL GON5TRUCTION LOAOS, AND TRAFFlC
LOADING DIAGRAM FOR ONE-TIER TIEBACK SYSTEM
.
� ������I
Calculation Sheets
FOLIIti'DEITIOI�� C.tQI�iT?A14''�'`
Project:,Vail Front Door Contract No.• 07-3715
Location:Vail,CO. Sheet No.: �ttc/50
Owner: VRDC Date: Feb. 17,2006
General Contractor: Hyder Construction,inc.
EXISTfNG GRADE (TYP.)
. .
.2H
H1
H = HEICHT OF SOIL'IN FEET �
H 1 = DEPTH TO FIRST TIE6ACK IN FEET
H2 = DEPTH FROM FIRST TIEBACK TO :SECOND
k�t TIEBACK IN FEET -
B� � B1 = H4RIZONTAL/FIRST TIEBACK LOAD IN-KIPS/fT
82 = HORIZONTAI/SECOND TIEBACK LOAD IN KIPS/fT
M1 = 50LDIER BEAM MOMENT AT�TIEBACK IN-JC—FT/FT
MM1 = A1AXlMUA1 SOLDIEit BEAM MOMENT .BETWEEN.
FIRST TIEBACK ANQ SECOND TIEBACK IN K-FT/FT
MM2 = MAXIMUM SOLDtER BEAM 610i�ENT BETWEEN
SECOND TlEBACK: AND SUBGRADE-iN K—FT/FT
MM i ,6H
N2 H
� RESULTS SWOWN IN CALCU[ATIONS ARE
FR�M A COMPUTER PROGRAM FRINTOUT
62
MM2
H3 �%' .2H 80TTOM OF EXCAVATION
LOAD tNTENSITY INCLUOES SURCNARGE DUE TO
P=.025H NORMAL CONSTRUCTiON LOADS, AND TRAFFIC
LOADING DIAGRAM FOR TWO-TIER TIEBACK SYSTEM
.
'
�C���l Calculation Sheets
Fovtww�or� co:�rn�
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wafl Shoring-Lodge at Vail Sheet No.: ��
Owner: VRDC . Date: February 17, 2006
General Contractor: Hyder Construction lnc. By: CHB
Rev. By.: JAF
Ca�e #13 (see 12/28/05 calculation submittal): Soldier Beams 49-50
Desiqn parameters for a two tier svstem:
H=40 ft (design height)
H1 = ]0.027ft (depth to tieback row 1)
H2 = 15.582 ft (distance from tieback row 1 to row 2) '
S= 10 ft (spacing)
a 1 =20 deg
a2= lOdeg TIEBACK DESfGN
B 1 = 15.155 kips
B1•S
DLT1 := DLTI = 161.274 kips
cos�a��•1 ft
use 5-0.6"strand anchor Lu�= 12ft
B2= 12.909 kips La:= 35ft
B2S
DLT2:= DLT2= 131.077 kips
cos�a2�•1 fr
use 4-0.6"strand anchor Lu'- 7ft
La:= 30ft
SOLDIER BEAM DESIGN
Ml =-20.829kips•ft
MMI =20.829kips•ft
MM2=20.829kips•ft
M�:= 20.829kips•� �
If
Mmax'S
re 75.742 in3
s q� 0:66•Fb �
use 2-W14x30 Sall�= 84in3
Copyright 20U5,Schnabel Foundation Company
�
�- �chna.bel �alculation Sheets
" � FOUNDATTON COMPANy
Project: Vail Front Door Contract No.: 07-3715
Location: North/East Wal�Shoring Sheet No.: 5 a /eo
Owner: VRDC Date: February 17, 2006
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #14: Soldier Beams 51-54
Desiqn parameters for a one tier svstem:
H=21 ft (design height)
H1 =7 ft (depth to tieback row)
S= ]0 ft (spacing) �
a =20 deg
TIEBACK DESIGN
B1 =6.615kips
DLTI := B1 S DLT1 =70.395kips
cos�a�•1 ft
use 1"� 150ksi bar Lu�= Sft
I-a:= 20ft
� SOLDIER BEAM DESIGN
M1 =—6.688kips•ft
MMlt=8.875kips-ft
Mmax:= 8.875kips.ft
If
M�S
�req:= Sfeq=32273 in3 -
0.66�Fb
� use 2-C12x20.7 3
Sa��:= 43in
Copyright 2005,Schnabel Foundation Company
♦
DESIGN CALCULATIONS
Submitted to:
Hyder Construction, Inc.
for:
Vail Front Door-
North and East Excavation Shoring
VAIL, COLOR.A.DO
by: REVIEWED BY
SCHNABEL FOUNDATION COMPANY MAY 2 6 20
Job No. 07-3715
COLORADOINSPE ION
AGENCY
December 28, 2005
.��P4�•R�G�S
O���p.FR,q� ��,c
CUe�Ao
.
. �;
.
-o• S
��- . �
.,,z .�.Q��,.
�••o...•• �
"�ONAL�
John A. Franceski
COLORADO P.E.#28034
Schnabel
FOUNDATTON COMPANY
����'����� Calculation Sheets
rov.v�a��nor co�m,�.t��x'
Project: Vail Front Door II Contract No.: 07-3715
Location:Vaii,CO. Sheet No.: i Mz
Owner: VRDC Date: Dec:28,2005
Generat Contractor: Hyder Construction,Inc.
Design Calculations-
North and East Temporary Shoring Walls
TABLE OF CONTENTS: �
LODGE SOUTH MICROPILES.........................................................Sheet 2
TEMPORARY SOIL NAIL WALL.....................................................Sheet 8
SOLDIER BEAM AND LAGGING WALLS........................................Sheet 21
����'������ Calculation Sheets
FOUi`r`t7ATT0\ CC)�iPA,i'�'X
Project: Vail Front Door II Contract No.: 07-3715
Location:Vail,CO. Sheet No.: 2/NL
Owner: VRDC Date: Dec:28,2005
Generat Contractor: Hyder Construction,Inc.
Lodge South Condominium Micropiles
The following sheets outline the design for the micropiles that will support the
existing Lodge South building. The footing sizes were inferred from the Lodge
South Condominium drawings provided(Sheets S1 and S7).There are 4 design
cases; 8'-0", 7'-6", 6'-6" and 4'-0"square column footings, all with an assumed �
bearing pressure of 5 ksf. For this design all of the column footings are assumed to
be at approximately the same elevation.If during construction, a differing condition
is discovered additional design work may be required.
The micropile lengths presented are the total length required to develop the
necessary test capacity (@ 5 kips per foot)plus the distance from the bottom of the
existing footing to the intersection of the micropile with a theoretical failure plane
(measured as 45°+cp/2 from the bottom of the proposed footings).
• • � - � • ' • . � : : • • • � • •
. .
:,� t ^,2 I�b° . �� . , ��`4's. ' - i e-tt � 'v r t ,2. � m a.v5 b+ ...!,�ys"H ° k r "5-^i� si- �:x:� :�
•'-�; .,.'11`,��'i�'., 1, ` ^a"g�� ^`'C.�+..�' U- .�r+��;�" ;ys�r?` �� r !�r.' �a a ' ��'y�`,t �il't=�,� ?,+ f r a� ra rt E_
p"�,�
Enter data.in yellow cells., ;
Building Code
Code to be Used for Analysis:
Micropile Construction Details
Bar Size:
Bar Area(inZ):
Bar Steel Yield Stress(ksi):
Casing OD(in}:
Casing Area(inZ):
Casing Steel Yield Stress(ksi):
Uncased Hole Diameter(in):
Grout Area-Casing Oniy(inZ):
Grout Area-Bar Only(in2):
Grout Area-Casing&Bar(inz):
Grout Strength(ksi):
Grout Elastic Modulus(ksi):
��
T76N
z.sa
95.07
4
3.14
..: .
5
1000
Coupling diameter(in.): 3.74
Overall length(ft.): 42.000
Casing Bar Casing 8�
Allowable Strength Design Onl Onl Bar
Ai�owable Strength of Steel(kips): 116.44
Allowable Strength of Grout(kips): 6.28
Total AAowable Strength(kips): 122.72 =(Area�E�x as�E�x fY)+(Area�ROUT X�cROUr x f�)
Strain Compatibility Analysis @ Design Load
Design Load(kips):
Estimated Load in Steel(kips): 77.1 �
Estimated Load in Grout(kips): 2.9 �1
Strain Compatibility Analysis @ Pdaximum Test Load
Maximum Test Load,TL(kips): 1
Estimated Load in Steel(kips): 154.1 r►
Estimated Load in Grout(kips): 5.9 �■►
Micropile Design for Axial Load-7'-6"x7'-6" Column footing/4 Micropiles
Compression
� .,. � ,
v�e� "�"�i�+.�� n�° "^'_� ��"��• � ?t�' '�.i'�. _'��',a�a '���qe'„�..�„,� , �� �-
°..i �'��g:"�,�c��v':�� s..%:....�aw�.��`w Rt��� �� u„t �t,,c.:4��5 E . .. ��'�.�:t�t° '`,���:��_.��
Enter data in yellow cells.
Buiiding Code
Code to be Used for Analysis
Micropile Construction Detaifs
Bar Size:
Bar Area(inZ):
Bar Steel Yield Stress(ksi)�
Casi�g OD(in):
Casing Area(inZ):
Casing Steel Yield Stress(ksi):
Uncased Hole Diameter(in):
Grout Area-Casing Only(inz):
Grout Area-Bar Only(in2):
Grout Area-Casing&Bar(inZ):
Grout Strength(ksi):
Grout Elastic Modulus(ksi):
��
T76N
2.84
95.07
4
3.14
5
1500
Coupling diameter(in.): 3.74
Overall length(ft.): 38.000
Casing Bar Casing&
Allowable Strength Design Onl Oni Bar
Allowable Strength oi Steel(kips): 116.44
Allowable Strength of Grout(kips): 6.28
Total Allowable Strength(k+ps): 122.72 =(Areas��x asTE�x fY)+(Areacaour x�ROUr x f�)
Strain Compatibflity Analysis @ Design Load
Design Load(kips):
Estimated Load in Steel(kips): 67.2 �►
Estimated Load in Grout(kips): 3.8 �►
Strain Compatibility Analysis @ Maximum Test Load
Maximum Test Load,TL(kips): 4
Estimated Load in Steel(kips): 134:3 �►
Estimated Load in Grout(kips): 7.7 �/
�
s
r
• � � - � • � • . • • • • � � • •
. . .
��k:.;"f'�., ,.v�r7"s�'.��`R'�w:�a �P,;.w^w�� �i�'�'`° A'�:: �s. a. ''.�7��,?c"a�'� 3 M 4e� _ .���� ��,{' �,... �',+.'�°��s 'ya�',�'
C3: k� �h,.-, :�r,s`u°,� �.�E !.s;;. +�lYI." °'c......�
Enter data in,yeliow cells.
Building Code
Code to be Used for Analysis:
hficropile Construction Details
Bar Size:
E3ar Area(inZ):
Qar Steel Yield Stress(ksi):
Casing OD(in):
Casing Area(in2):
Casing Steel Yield Stress(ksi):
Uncased Hole Diameter(in):
Grout Area-Casing Only(inz):
Grout Area-6ar Only(inZ):
Grout Area-Casing&Bar(in2):
Grout Strength(ksi):
Grout Elastic Modulus(ksi):
�
--:R51 N
1.46
96.99
�q
1.33
,:��:=<:5
,�: . . .
1500
- �x�,�
• ^ �'c^4'°'QL ,�f?,.� r'r e, .. •:�.B�•0�\�\�����\�\�
t . e �� ,"�.e�•e ��_, ��a��������������
�`.i3°�' ��L.�N:„���":� ,ti?��f'fa,�'+',��;.:��t...g,_'�"'�....m,`=;0�� ��'':�+.�,ri= .
�°�°�\�\\`i\�\\��E��� ��;� ,�-��, q\'\�\\\\`\\�S\
°F��� ����-E....�_.�`•������ �r�i.- ��:'uq ^'�i` 'if'�: -
' � -� 1 � � •• . • • 1 �1 • • '• • •
Coupling diameter(in.): 2.48
Overall length(ft.): 31.000
Casing Bar Casing&
Allowable Strength Design Onl Onl Bar
Allowable Strength of Steel(kips): 59.86
Ailowable Strength of Grout(kips): 2.65
Total Allowable Strength(kips): 62.51 =(Areas��x as��,x fy)+(AreacROUr X«caour x f�)
Strain Compatibility Analysis @ Design Load
Design Load(kips): 3
Estimated Load in Steel(kips): 50.6 _1
Estimated Load in Grout(kips): 2.4 _►
Strain Compatibility Analysis @ Maximum Test Load
tiiaximum Test Load,7L(kips): 1
Estimated Load in Steel(kips): 101.2 �►
Fstimated Load in Grout(kips): 4.8 0/
Micropile Design for Axial Load-4'x4' Column footing/4 Micropiles
Compression
�� �� 1 ���,yt�i n.;^. nq'^ S��s� 'u- g .+�4�.�-{:. :���t�p'�a �j � :5++�u}E� h. :i„'n . . _a,�p�E4'ti `�% .�i a'"^7"�'h,T��r'�i5,. "�'S�9T f��3!'��t&:;`-;�
...,.��Y:�. ::�.: . �._ad;�"�« .�.n.e.o-.......�SR..,?u..3« '�i'...i�u.:�.� ,. ,•1 .,��''„.F< < �.�x�. :� �� �� .M.... -�nee k..�.. ?. �4M
�
,
� .... �.. _.: t.,..:... z�,�.::,..�a:a,i �_:_� .� .i.�G:'6:,�:s a,�. _.... �......,�..a�.,1a_�i.a6..........:��' �.�� ,z�r:�. ...�..,..:�:,caai,;.
Enter data in yellow celis.
Building Code
Code to be Used for Analysis:
Micropile Construction Detaiis
Bar Size:
Bar Area(inZ):
Bar Steel Yield Stress(ksi):
Casing OD(in):
Casing Area(in1):
Casing Steel Yield Stress(ksi):
Uncased Hole Diameter(in):
Grout Area-Casing Only(inZ):
Grout Area-Bar Only(inZ):
Grout Area-Casing 8 Bar(in2):
Grout Strength(ksi):
Grout Elastic Modulus(ksi):
---ri:�
R51L
1,20
84.33
4
1.58
5
1500
Co�,f . ,aST�'�ii��m.ax�.lksiE,� „�CROii.t����?aXm(ksi1.�
�HV.J�A'��► 0:�� �"�����i :Q'�:4:0'
r �" 0.
, , . , .. ,
. ,
f��op � 4�:� � . ��, �
MA t�t�`�� ' �.p 4.:��?!�,��3��.,.4 Q.&�� �
, . ,..,.
Chica�'o,���- � '=s�.�1:8 �:.se(ect;
Custo��� ;::' w ,.�.��`" . . ,. , .r :_ �,.�
"Select acROUr=0.25 for unconfined grout or .40 for confined grout
Coupling diameter(in.): 2.48
Overall length(ft.): 18,000
Casing Bar Casing&
Aliowabte Strength Design Onl Onl Bar
Allowable Strength of Steel(kips): 47.56
Allowable Strength of Grout(kips): 3.17
Total Allowable Strength(kips): 50.73 ={AreasrEE�x«gTE�x fY)+�Af28GROUT%�aGROUT X rC)
Strain Compatibility Analysis @ Design Load
Design Load(kips):
Estimated Load in Steel(kips): 18.7 �
Estimated Load in Grout(kips): 1.3 �►
Strain Compatibility Analysis @ Maximum Test l.oad
Maximum Test Load,TL(kips): 4
Estimated Load in Steel(kips): 37.4 �
Estimated Load in Grout(kips): 2.6 y
c
S
N
5c�u��a.bel Calculation Sheets �
J FOLJNDATTON COMPANY
Project: Vail Front Door fl Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: '3-/k�-
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Micropile connection to Lodqe South Condominiums:
The micropiles will be installed through the existing footing, capped with a nut, topped with grout and cut off flush with
the top of footing.A cap plate will be wet set over the micropile and anchored to the existing footing using four(4) high
capacity concrete anchors. We have assumed the interface between the grout and footing to be frictionless, and
therefore incapable of supporting any load.
For#he 6'-6"x 6'-6"co(umn footings the axail load on the micropile is 53 kips. This load will be distributed among 4 high '
capacity concrete anchors.
(6.Sfr•6.Sft)-Sksf
TL:= TL= 13.203 kips
4•4
For the 8'-0"x 8'-0"column footings the axail Ioad on the micropife is 80 kips.This load wilf be distributed among 4 high
capacity concrete anchors.
,I, (8ft•8ft}•Sksf T 20ki s
L�= 44 L= P
For the 7'-6"x 7'-6"column footings the axail load on the micropile is 71 kips. This load will be distributed among 4 high
capacity concrete anchors.
(7.Sft•7.Sft)-Sksf
TL:= TL= 17.578 kips
4-4
Use 1"-8 R1 H"SPIN-LOCK"hoflow rebar concrete anchor,ASTM A-615 Grade 60
Design Ioad at FS=2: 33,000 Ibs., Minimum embedment: 14"for 3000psi concrete
Edge distance: 15"minimum
Center to center. 12"minimum
Drill hole diameter: 1-3/4"
For the 4'-0"x 4'-0"column footings the axail load on the micropile is 20 kips. This load will be distributed among 4 high
capacity concrete anchors.
(4ft•4ft)�Sksf
TL:= 4 4 TL=5 kips
Use 'I/2"-13 R1J"SPIN-LOCK"solid rebar concrete anchor,ASTM A-615 Grade 60
Design(oad at FS=2: 7,5001bs., Minimum embedment:7"for 300Qpsi concrete -
Edge distance: 8"minimum
Center to center: 6"minimum
Drill hole diameter: 1-1/4"
Copyright 2005,Schnabel Foundation Company
� �C����� Calculation Sheets
FOLI�'DATION CQ�iI���i
Project: Vail Front Door II Contract No.: 07-3715
Location:Vail,CO. Sheet No.: g/yz..
Owner: VRDC Date: Dec.28,2005
General�Contractor: Hyder Construction, Inc.
Temporary Soil Nail Wall- North Shoring Wall
Under Lodge South Condominium
The temporary soil nail shoring under Lodge South Condominium was designed
using SnailWin 3.10 by the California Department of Transportation. Two external .
loads were applied to the wall; the first is due to surcharge loading imposed by the
micropiles, and the second is a theoretical load at the columns which was included to
make the system more rigid.The micropiles are designed for 100% of the load
imposed by South Tower building. �
Overall factor of safety: 1.35
o.c.: iz-za-zaes SnailNin 3.18 Yilec OP)-S��[A i�wr H�77ENEDS�AQIYtCE
Mlnlmum Factor of Safety = 1.35
5.1 [t Behind 4a11 Crest
R[Wll 7oe
LECQJD:
- PD- -3.6 Wtt
. PS- 40_B Niys
X� 17.8 f[ PV� 11.3]Isi
6h� S.B ft
Su- S.B ft
CJin PIIy[ CON Svt
3 125fB d34 �B IS�B
SeaL-18 Ft � furcMrg� -� Ext.Porce-PD
Pigure 1: Graphical output from SnailWin showing the wall geometry.
����1�'�bi.i Calculation Sheets
POU?�'UATION CQi�ti'�'1,�'Y'
Project: Vail Front Door II Contract No.: 07-3715
Lxation:Vail,CO. Sheet No.: q�ky
Owner: VRDC Date: Dec.28,2005
General Contractor: Hyder Construction,Inc.
The surcharge load due to the existing building columns was assumed to be located
2.5' behind the shoring and support a load of 300psf to 10' behind the shoring.
Because the micropiles supporting South Tower are designed to carry the entire
surcharge load there is theoretically no need to include this surcharge in the design.
However it is included to stiffen the shoring system and limit deflection.
The other external load accounted for in the design is due to the micropiles that
support the South Tower building.It is a 3.62kips/linear foot load applied
horizontally to the wall. See Figure 2 below.
0 0.05 0.1 0.15 0.2 0.25 0.3 0.35
0 .,,;�;Y ;.
Z
4
6
,
�-
.
a � .� <�.: � T
�. r �_ .,
I a '
I 10 -
l`:
#
12 ' i e o
14 �
16 �� �a
Figure 2: Compiled lateral loading imposed on the shoring. The above line consists of
sixteen Boussinesq curves calculated using the computer program LPRES by Civiltec. The
compiled data represents the surcharge loading imposed by the micropiles that support the
South Tower building. Zt was modeled as a 5 kips per vertical foot load located 2 feet
behind the shoring starting from the top of the wall.
�C��l����� Calculation Sheets
1�Ot1I�'DATTOI� CQbII>,�'1uti'7�'
Project: Vail Front Door II Contract No.: 07-3715
Location:Vaii,CO. Sheet No.: Jo z
Owner. VRDC Date: Dec:28,2005 .
Generaf Contractor: Hyder Construction,Inc.
The text output from SnailWin is presented beIow. It includes the wall geometry,
external loads and design assumptions used in the analysis.
--------- WALL GEOMETRY ---------
Vertical Wall Height = 17.0 ft
Wall Batter = 6.0 degree
--------- SURCHARGE --------- '
Hegin Surcharge - Distance from toe = Z.5 ft
Snd Surcharge - Distance from toe = 10.0 ft
Loading Intensity - Begin = 300.0 psf/ft
Loading Intensity - End = 300.0 psf/ft
--------- OPTION #1 ---------
Factored Punching shear, Sond � Yield Stress are used.
--------- SOIL PARAMETERS ---------
Unit Friction Cohesion Bond� Coordinates of Boundary
Soil Weight Angle Intercept Stress XS1 YS1 X52 Y52
Layer (Pef) (Degree) (Psf) (Psi) (ft) (ft) (ft) (ft)
1 125.0 34.0 0.0 15.0 0.0 0:0 0.0 0.0
* Bond Stress also depends on SSF Factor in Option #5 when enabled.
--------- EXTERNAL FORCE ---------
Horiz. Force applied to the Wall = -3.6 Rips
--------- REINFORCEMENT PARAMETERS ---------
Nwnber of Reinforcement Leve2s = 3
Horizontal Spacing = 5.0 ft
Yie2d Stress of Reinforcement = 41.3 ksi
Diameter of Grouted xole = 3.0 in
Punching Shear = 29.0 kips
---------- (Varying Reinforcement Parameters) ---------
Vertical Bar
Level Length Inclination Spacing Diameter Bond Stress
(ft) (degrees) (ft} (in) Factor
1 22.0 15.0 2.0 1.00 1.00
2 22.0 15.0 5.0 1.00 1.00
3 22.0 15.0 5.0 1.00 1.00
MINIMUM DISTANCS LOWER FAZLURE UPP&R FAILVRfi
SAFETY BEHZND PLANE PI.ANB
FACTOR WALL TOE ANGLE LENGTH AI3GLE LENGTH
(ft) (deg) (ft) (deg) (ft)
NODE 2
1.352 6.8 35.4 5.9 61.4 13.8
Reinf. Stress at Level 1 = 36.856 Ksi (PUllout controls...)
2 = 37.348 Ksi (PUllout controls...3
3 = 37.840 Ksi (PUllout controls...)
The following sheets detail the facing design for the temporary soils naiIs along the
north wall of the excavation.
n/yz
�Schnabel
FOUNDATION COMPANY
. Schnabel Foundation Company
Vail Front Door-South Tower Temporary
December 28,2005
FHWA Design Procedure
for
Determining Nail Head Strengths
for a
Specified Soil Nail Wall Facing
Version 3.0
(Updated 10/29/2004)
Summary: This program utilizes FHWA's DP103 design guidelines to
caiculate the nait head strength for a soil nail wall facing. Both
temporary and permanent shotcrete or cast-in-place(CIP)concrete
facings can be analyzed. The procedure considers earth pressure
redistribution on relatively thin temporary construction facings. The
program considers three potential failure modes: flexural failure.
punching shear failure, and tensile failure of headed studs. Both
nominal (ultimate) and allowable nail head loads are given. An
empirical earth pressure formula is used to estimate nail head
service loads for comparison with the computed allowable loads.
The allowable load shall be greater than the load given by the
empirical earth pressure formula. The capacity of the upper -
cantilever portion of the facing is also checked.
AASHTO requirements taken from "Standard Specifications for
Highway Bridges",16th Edition,1996.
Tables and figures referred to in the calculations are taken from
FHWA's "Manual for Design and Construction Monitoring of Soil
Nail Walls-Demonstration Project 103", 1996.
Please enter project information:
i�Y� 'Schnabe�;Foundat�on'Gompany ';�
<Vad,Front Door;;.,outh Toyirer�Teniporary;_!
;� , ,� �v.;December28 2005 �.�>.��,�
. � . � Introduction
- ,� -�� � � - -�� �� � �� � � Copyright 2004 Schnabel Foundation Company .
�2/HZ
.
Schnabel
FOUNDATION COMPANY
Schnabel Foundation Company
Vail Front Door-South Tower Temporary
December 28,2005
� '° t�������� fiY�#-&`� �-. �&r . 's+�-'.�-r.�,`... �x v-� a �� �s.r .�
��������. �' .� ����' `Temporary�Shot�refe��acing� � � ,�' ��.
Enter the following variables:
Note:Enter 0 if not app/icable
AASHTO Load Combination 1,4 or 7:(Tabie 4.3) �
Naii Spacing
Horizontal nail spacing�(ft) 5.OQ;;
Vertical nail spacing:(ft) ' S.00;:;
Shotcrete Thickness and Strength
Shotcrete/concrete thickness:(in) 4.00 : :
Shotcrete/concrete compressive strength:(psi) 4000 �
Welded Wire Mesh
Area of inesh:(in^2/ft)(See Table F.1) - Oi04]Y':�
Wire spacing:(in) =6.00<`:;i Reyui�edie�yrn onaP saice pn�= a.00
Yield stress:(ksi) 60 ''=' AASHTO,16th Edition,Artic/e 8.32.6.1,pJ94
Horizontal Waler Bars
Quantity of bars per nail: 2 �= Reyuiredienyrn o�iaP Sp�icB p��= sosz
Bar size#:(3-9} 4 ; ':' aasHro,16th Edition,Article 8.32J.4,p.193
Yield stress:(ksi) 60 w, No�-�o�racr�ap SP�ices see n.n��e e.3z.t3
Vertical Bearing Bars
Quantity of bars per nail: ; :p;,°°;r
Bar size#:(3-9) 4 ��
Yield stress:(ksi) 60 "•'
Bearing Plate Details
Bearing plate width:{in) ', ;8:00'<
Bearing plate thickness:(in) 0:75:`<
Diameter of nail tendon hole:(in) 1.50">`"
Yield Stress:(ksi) 36-'i?
Dril!Hole Diameter:(in) �3
Temporary Facing
- � � - - Copyreght 2004 Schnabel Foundatfon Company .
IS/yz
Minimum and Maximum Reinforcement Ratio Check
AASHTO Requirements:
—►To Ensure Ductile Failure:
Minimum reinforcement ratios: (requirement waived per FHWA,DP 103,Section 4.7.1,p.106)
Maximum hcxizonta!reinforcement ratio: s�0"021.9� aasrrro,16th Edifion,ArtFcle 8.l6.3.1.1,Eq.8-18
Maximum vertical reinforcement ratio: 0 021d� AASHTO,f61h Edition,Articfe 8J6.3.1.1,Eq.8-18
Checking AASHTO maximum steel requirement...
OK
�Shrinkage and Temperature Reinforcement:
None required per FHWA,DP 103,Section 4.7.1,p. 106
FHWA Requirements:
A reinforcement ratio(based on gross area)of no more than 0.0035 should be considered if C�>1.
FHWA,OP 103,Secfion 4.5.2,p.89
Checking FHWA maximum steel requirement...
OK
Flexural Strength Calculations
Flexure Pressure Factor,Cf,(Table 4.2)_ -:';2A ?
Horizontal Positive Moment Capacity(kip-fUft)= 1.16
Horizontal Negative Moment Capacity(kip-fdft)= 1.16
Vertical Positive Moment Capacity(kip-ft/ft)= 0.40
Verticaf Negative Moment Capacity(kip-ft/ft)= 0.40
Nom.Nail Head Strength for Flexure,Tm(kips)= 12.92 ••Vertical moment capacities govern.
Allowable Nail Head Load for Flexure,T�(kips)_ �8,�66��
"See Table 4.4 == CONTROLS
Punching Shear Calculation
Internal Punching Shear SVength,V„(kips)= 38.15
Do you wish to consider soil reaction contribution to punching capacityl ; Yes :
Shear Pressure Factor,C5,(Table 42)= 2.0< >
Nominal Punching Shear Strength,Tm(kips)= 42.77
Allowable Nail Head Load for Punching,Tf(kips)= y�=28:65;�
'*See Table 4.4
Empirical Minimum Allowable Nail Head Service Load Check
Enter the following variables:
Empirical ccefficient F:(0.3-0.7,use 0.5) 0.5 ;:`;
Active earth pressure coefficient Ka:' - 0:3 =<;
Soil Unit Weight:(pc� 120 '
Wall Height:(ft) `':'18 '::
•If Ka is not known,enter Ka=0 above and
estimate active load Pa:(kips/ft of wall) �
Estimated Nail Head Service Load(kips)_ �`::�1,0:�;�
Facing design exceeds estimated service load requirements. No revision required.
Temporery Facing
- • Copyright 2004 Schnabel Foundation Company
Schnabel
FOUNDATION COMPANY
Schnabel Foundation Company
Vail Front Door-South Tower Temporary
December 28,>2005
•-r �: a . • = r.� � � �-sr�y�� �:�'
: K, _
.�,,�y,- � ��� �� �,e�C,anfilever�.,Des� �:�;�� .a
�, • �:-,
hec
FHWA requires that the upper cantilever portion of soil naii wall facings be checked for structural adequacy.
This check is required because the upper cantilever is unable to distribute load by soii arching to adjacent spans.
Permanent facings must also be checked for serviceability.
IMPORTANT: Do you wish to calculate values corresponding to the
Temporary Facing or Permanent Facing worksheet? •Tempo�ary �_�
Enter the following variables:
Upper cantilever span:(ft) `'' 2 '.
Active earth pressure coefficient Ka:'
Soil unitweight:(pcf� '_125 ': ,
Surcharge load:(psfl `:�'300 ;�::
`If Ka is not known:
1. Enter Ka=0 above
2.Estimate active load Pa:(kips/ft of wall) �
3.Enter point of application:(ft above the nail head)
Shear Capacity
Nominal shear strength of cantilever:(kips/ft) 3.04
Allowabfe shear strength of cantilever. (kips/ft) 2 03�
Estimated service shear.(kips/ft) ' -�:3(Y� Shear capacity OK. No revision required.
Moment Capacity
Nominal moment capacity of cantilever: (kip-ff/ft) 0.40
Allowable moment capacity of cantilever.(kip-ft/ft) ;�U':2'f,",
Estimated service moment: (kip-fUft) :��;„�aQ.27� Moment capacity OK. No revision required.
Serviceability Check
Service steel stress limit: (ksi) �;�I,:,° �, :
Service stee!stress:(ksi) ��iFl`�
Upper Cantilever
Copyright 2004 Schnabel Foundatiort Company
Schnabel
_ FOUNDATION COMPANY
Schnabei Foundation Company
Vail Front Door-South Tower Temporary
December 28;,2005
mt '" ,�R'a:_. .� .._ S A`''ya`S"" .. fv'�.! '� '13 �^.,+N' �� � '�.z� _ _ pK
�=r � ��� ,� -����� ' Tables�4���4�3�°4�`4��F 1 and F 3��� r;.
��i:a� uH� ,w,y�,n �.., .r.�...<„f.� _.s f;. �..�� t�
Table 4.2
FacingPressure Factors Recommended forDasi�
Temporary Facings Permanent Facings
Nominal Facing Flexure Pressure Shear Pressure Flexure Pressure Shear Pressure
Thickness(in) Factor CF Factor Cs Fador CF Factor Cs
4 2.0 2.5 1.0 I.0
6 1.5 2.0 1.0 1.0
8 ].0 1.0 1.0 I.0
Table 43
Load Combinations in AASHTO Specifications
Group D L E B RST EQ %
I 1 1 1 1 0 0 ]00
IV I 1 l 1 1 0 125
VII I 0 1 1 0 1 133
Notes: D=dead load
L=live load
E=earth pressure
B=buoyancy
RST=rib shortening, shrinkage,temperature
EQ=earthquake
Table 4.4
Nail Head Strength Factors-SLD
Failure Mode Nai!Head Strength Nail Head�renb h Nai(Head Strength Factor
FactoraF(Group I) Factor aF(Group I� aF(Group Vll)
Facing Flexure 0.67 1.2�(0.67)=0.83 1.33(0.67)=0.89
Facing Punching Shear 0.67 1.25(O.b7)=0.83 1.33(0.67)=0.89
Headed Stud Tensile Fradure
ASTM A307 Bolt Material 0.50 1.2�(0.50)=0.63 1.33(0.50)=0.67
ASTM A325 Boh Mazerial 0.59 1.2�(0.59)=0.74 1.33(0.59)=0.78
Tables
Copyright 2004 Schnabel Foundation Company
1[�/"IL
Table F.l(modified)
Common Stock Sty(es of Welded Wire Fabric
Style Designation Steel Area(inZ/ft) Metric Style Designation
- New Old
6x6-W1.4xW1.4 6x6-1Ox10 0.029 152x152MW9.1 xMW9.1
6x6-W1.7�W1.7 6x6-9x9 0.034
6x6-W2.1xW2.1 6x6-Sx8 0.041 152x152MW133xMW13.3
6x6-W2.SxW2.5 6x6-7x7 0.050
6x6-W2.9xW2.9 6x6-6x6 0.0�8 152x152MW18.7xMW18.7
6x6-W3.4xW3.4 6x6-5x5 0.067
6x6-W4.OxW4.0 6x6-4x4 0.080 152x152MW25.8xMW25.8
6x6-W4.7xW4.7 6x6-3x3 0.094
6x6-W5.4xW5.4 6x6-2x2 0.108 152x152MW34.9xMW34.9
6x6-W6.3xW63 6x6-lxl 0.126
6x6-W7.4xW7.4 6x6-Ox0 0.148
4x4-W1.4xW1.4 4x4-1Ox10 0.043 102x102MW9.1 xMW9.1
4x4-W1.7xW1.7 4x4-9x9 0.052
4x4-W2.1xW2.1 4x4-8x8 0.062 102x102MW13.3xMW13.3
4x4-W2.SxW2.5 4x4-7x7 0.07�
4x4-W2.9xW2.9 4x4-6x6 0.087 102x102MW18.7xMW18.7
4x4-W3.4xW3.4 4x4-Sx5 0.101
4x4-W4.OxW4.0 4x4-4x4 0.12 102x102MW25.8xMW25.8
4x4-W4.7xW4.7 4x4-3x3 0.140
4x4-W5.4xW5.4 6x6-2x2 0.162
4x4-W6.3xW6.3 6x6-]xl 0.189
4x4-W7.4xW7.4 6x6-Ox0 0.221
{
Tables
Copyright 2004 Schnabel Foundation Company
iT�y�
Table F.3
_ Dimensions of Stock Size Headed Studs
Anchor Size Nominal Area(in� After Weld Length(in) Head Diameter(in) Head Thickness(in)
�1/4 x 2 11/16 0.049 2 9/16 0.500 0.187
1!4 x 4 1/8 0.049 4 0.500 0.187
3/8 x 4 1!8 0.1 IO 4 0.750 0.281
3/8 x 6 1/8 0.110 6 0.7�0 0.281
'/�x 2 1/8 0.196 2 1.000 0312
'/:x 3 1/8 0.196 3 1.000 0.312
%z x 4 1/8 0.196 4 1.000 0.312
%:x 5 5/16 0_196 5 3/16 1.000 0.312
%,x 6 1/8 0.196 6 1.000 0312
'/:x 8 1/8 0.196 8 1.000 0.312
5/8 x 2 i ll16 0307 2%= 1.250 0.312
5/S x 6 9/16 0307 6 3/8 1.250 0.312
5/8 x 8 3/16 0307 8 1.250 0.312
3/4 x 3 3/16 0.442 3 1.250 .375
3/4 x 3 11/16 0.442 3%: 1.250 .375
3/4 x 4 3/16 0.442 4 1.250 .375
3/4 x 5 3/lb 0.442 5 1.250 375
3/4 x 6 3/16 0.442 6 I.250 375
3/4 x 7 3/16 0.442 7 1.250 .375
3/4 x 8 3/16 0.442 8 1.250 .375
7/8 x 3 11/16 0.601 3% 1375 375
7!8 x 4 3/16 0.601 4 1.375 375
7/8 x 5 3/16 0.601 5 1375 375
7/8 x 6 3/16 0.601 6 1.375 375
7/8 x 7 3/16 0.601 7 1375 .375
7/8 x 8 3/16 0.601 8 1.375 375
Tables
Copyright 20D4 Schnabel Foundation Company
�f /HL
Schnabel
FOUNDRTION COMPANY
Schnabel Foundation Company
Vail Front Door-South Tower Temporary
December 28,2005
,.. . ., . .. -r. ., .
�. �
�r.
:..
,
�
- ° ���.., ,.�..Fi ures,1 4 9�a��.;f�.s 3:�_ `
�:w•. . . ,. ��,. �•,,;. � ..._.:,� , ,:. ._
.
shotcreie vwra h+ea�3+wler bars
vrrtica/bearing bus
ioil nail
{i�rt�oment
{-)f�ortfent �
Horizonial Section and MQments
� i
i I
�f hdiconul waiar Lan
soit nail � ()marrKnt
1
� lhOtt�lle i
i t.}�n< <
v.iro m�sh �
0 f
,�r��t�,.;���
•�I �
i
.� I
3 �
! 1
Vertical Section and Nioments
Figure 1 Typicat 5ection�ews with Moment D'sagrarns �
Figures
Copyright 2004 Schnabet Foundation Company
�1ltiz
� vYaler bars
a�� �-Intemai Facing Component
Failure Suc!-dce . � OI FiEStS�al7LE,V�
� � I ��P�
i
� '�- � o• �. T
. . h�
�
� � � -
Critical Diameter for
Strength Catculafioa
Lqcated at Mid-depth •
of Cane
Soii Component
�� o!Resistance
- � - Tiote_
- FN
� � ��GC� A� ; a DG/4 O'�T Dc-h� .
2
� � �c =xD��/4 -bPt+h�
_ � Temparary 8earirtg-Plate Connectiore
Failure Suriaca � TQ�___ . ,�nf�Resistance9�mponent
. . L ;--Srrs—I � � .
. � .
� •' �•c + . 4+s hfc
_J_..
' f
" . -� �
Critical Oiameter tor • �
S;rength CaEculat+on
tocat2d at Mid-depi� � . . �
of Cons . . Soii Component
ot fiesistance
Tlote: � -��. f+fofe:
'Femporary facing noi �
shown for clarity. ��QGC� , A� -rz D�1S D'p= D�-hc
. A� 2
� ''CGC= R D GG I4 . � -$g�„�+h�
� Pertnanent Headed-Stud ConnectFon
� Fsgure 4.9 Punching Shear�af Nai! Head Connecfians '
Figures
Copyright 2004 Schnabel Foundation Company
10/ti z
Surcl►arfla Load,q� •
. F�� '
� ,typkal Earth Pnuwre �
lioadtrg Cot�dltkt�.t •
• t.
UpPe�
Cant�svsr
span.H�,� " • .
� 8euk+9 �
PIaN . �
Cenler�ne of� • K"� ' KA 7 k'�ie � .
.Uppet Natl Row �
• � Crittca!Section for Chedcfip
' • Shear and Ftexure
Figure 4.13 ilpper Cantilever Design
Figures
Copyright 2004 S�hnabel Foundation Company
SC������� Calcufation Sheets
�ov�ivA�nor m�m��r
Project: Vail Front Door 11 Contract No.: 07-3715
Location:Vail,CO. Sheet No.• 21/tiz
Owner: VRDC Date: Dec.28,2005
Genera!Contractor: Hyder Construction,Inc.
Temporary Soldier Beam and Lagging Walls
The following design sheets pertain to the wall line soldier beam and lagging shoring
that will be installed along part of the north and east sides of the excavation.
Currently the design height extends from existing grade to the bottom of footing
elevations provided on Sheets S101-S103 dated OS/02/2005. �
Wall loads due to building surcharges were calculated using the computer program
LPRES by Civiltech Softrvare.
The soldier beams will be installed 2" off the proposed foundation wall with an
installation tolerance of+/-2".
�
. ��'�����1 Caicutation Sheets
FOLii\iDATIOI\' CO1�II't1i�`k'
Project: Vail Front Door il Contract No.: 07-3715
Location:Vail,CO. Sheet No.: 22/kz
Owner: VRDC Date: Dec.28,2005
General Contractor. Hyder Construction,Inc.
LOADING CONDITfONS
— HINGED SUPPORT ASSUf�ED AT EACH BRACE OR TIEBACK IXCEPT TOP T1ER
— HWGED SUPPORT ASSUMlED AT SUBGRADE
— SYSTE�A IS FREE—DRAINING (PIQ NYDROSTA7IC PRESSURE)
— LOADING DIAGRA�1 tNCLUDES SURCHARGE FOR TRAFFIC AND NORAIAL CONSTRUCTION LOAQS
(NEAVY.LOADS SUCH AS CRANES NOT INCLUDED)
— WHERE APPUCABLE, UP TO 337: REDIlCTION MNY BE TAKEN IN SOLDIER BEAM MdMENTS
PER: FOUNDATION EN6INEER(NG; PECK, � •
FUWSON. dc 7HDRtVBURN; 1974; pp — 453-463
— ALL ANCHORS TO BE LOCATED BEHIND FAlLURE PL1WE A5 FOLLOWS
•� /� � \ /`
UNHONDED �
L.ENGII-I �
/ IWCHOR LENGTH BEYaND
FNLURE PL/WE
/
/
/
1
/
/
/ 6Q'
/
'� .����' '\�,/.�
- VALUES SHOWN IN THE GALCULATIONS ARE TAKEN FROM A COf�fPUTER PRINTOLli
- ONLY THE CRfI1CAL MOMEM' IS SHOWN IN THE CALCUtATiONS
- ALLOWABLE BENDING STRESS FOR STEEL = 0.56Fy SINCE �LAt�EGES ARE FULLY
SUPPORTEO IN THE PLANE QF BENQING
�,�*�k�����1 Calculation Sheets
f�OG'NUATIOti C4,�iT'��1!'X
Project: Vaii Front Door II Contract No.: 07-3715
Location:Vail,CO. Sheet No.: 23/�iz.
Owner• VRDC Date: Dec.28,2005
General Contractor: Hyder Construction,Inc.
EXISTING GRADE (iYP.�
.ZH
H� N = HEIGHT QF SOIL tN FEET
H1 = DEPTH TO TIEBACK IN F'EET
H2 = DEPTH FROA1 TIEBACK TO SUHGRADE lN FEET
��t B1 = HORIZONTAL 71EBACK LOAO tN KIPS/fT
g� M1 = SOLD{ER BEAM MOMENT AT TIEBACK 1N K—Ff/FT
1 MA11 = MAXIAtUM 50LDIER BEAA1 M011ENT BE7INEEN
�J TIEBACK AND .SUBGRADE tN K—FT/FF
AIMt ,6H
� �
N2
,2N OTTOi� OF EXCAVATlON
LOAD INTENStTY INCLUDES SURCHARGE OUE TO
P_.025H NORMAL CONSTRUCTIQN LOADS, ANO TRAFFIC
LOADING DIAGRAM FOR ONE-TIER TIEBACK SYSTEM
� ��°�k���� Calculation Sheets
FOU�tI?ATLO� CQ�II'Ai�?Y
Project: Vail Front Door II Contract No.: 07-3715
Locatiori:Vail,CO_ Sheet No.: 2�S/kz
Owner: VRDC Date: Dec.28,2005
Generat Contractor: Hyder Construction,Inc.
EXISTINC GRAOE (TYP.)
.
.2H
H1
H = HEIGHT OF SOIL IN FEET..
H1 = DEPTH TO FIRST TIEBACK iN FEET
H2 = DEPTH FROM FIRST TIEBACK TO .SECOND
M� TIEBACK IN FEET
B� � 81 = HORIZONTAL/FIRST. TIEBACK lOAD IN KIPS/fT
82 = HORIZONTAL/SECOND 71EBACK LOAD :IN KIPS/FT
Mt = SOlD1ER BEAM MQMENT AT-TIEBACK ;IN-K—FT/ET
MM t = MAXIMUM SOLDtER BEAM MOMENT BETWEEN `
FIRST TIEBACK AND SECQNO TIEBACK [fN K—FT/FT
MM2 = I�AXIMUM SOLDIER BEAAd MOMENT BETWEEN
SECOND TFEBACK AND SUBGRADE IN K—FT/FT
MM1 .6N
NZ � H
RESULTS SHOWN IN CACCULATIONS ARE
FROM A COMPIJTER PROGRAM PR(NTOUT
B2
MM2
N3 � .2H OTTOM OF EXCAVATION
LOAD INTENSITY-INCLUQES SURCHARGE DUE TO
P=.D25H NORMAL CONSTRUCTIQN LOADS, AND TRAFFIC
LOADING DIAGRAM FOR TWO-TIER TIEBACK SYSTEM
. Sc�urx�bel Calcuiation Sheets
Fov_w�.�no� co�u>A,,��x �
Project: Vail Front Door II Contract No.: 07-3715
Location: Vail,CO. - Sheet No.: 25/4z
Owner: VRDC Date: Dec.28,2005
General Contractor: Hyder Construction,Inc.
� �
�
�` P�= ACTIVE EARTH PRESSURE (ACTS.ON CONTRIBUTORY
WIDTH OF SHORlNG TO SOLDiER BEAM ABOVE THE
BOTTOM OF EXCAVATION, ON WIDTH OF SOLDIER ,
BEAM BEIOW THE BOTTOAI OF EXCAVATION)
Pp= PASSIVE EARTH PRESSIYE (ACTS UPON THREE
H, TIMES DRIVEN BEAM WIDTN, THREE TIMES THE
DR[LL HOLE DIA6tETER, OR SOLDIER BEAA1 SPACING.
WHICHEVER IS LESS)
H = DEStGN HEIGHT IN FEET
H H'= HEIGHT TO TOP OF SLOPE IN FEET
BOTTON SPACIN6 = OISTANCE FROIA CENTER TO CENTER OF SOLDIER
OF BEAAt
EXCAVATION W = �DTH OF DRIVEN BEAM OR DRtll HOLE DIAMETER
0 = TOE PENETRATION IN FEET (DMfN=H)
MMAX = MAXiMUAI MOMENT IN SOLDIER BEAM IN KIP–FEET
FB = ALLOWABLE BENOING STRE55 OF STEEI SOL0IER
„ � BEAM IN KSI ` : "
SREQ = REQUIRED SECTION AtODULUS IN CUBIC ENCHES
LMIN = f�fIN1AtUM LENGTH OF SOLOIER BEAM H+D(LMIN=2'H)
D M
��---PP —P��
EARTH PRESSURE DtAGRAM — CANTILEVERED RETENTION SYSTEM _
. 5c1�►�:�abel Calculation Sheets
FOUNDAT'ION COMPANY
Project: Vai� Front Door II Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: z�j�rZ
Owner: VRDC Date: December 28,2005
Genera!Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #1: Soldier Beam 1
Desiqn parameters for a one tier svstem:
H= 13 ft (design height)
H1 =3 fr (depth to tieback row)
S= 10 ft (spacing} '
a =20 deg
TIEBACK DESIGN
B 1 =2.197 kips
B1•S
DLT1 := ` DLTI =23.38kips
cosla�•1 ft
use 1"� 150ksi bar L,,:= 7ft
La:= 20ft
SOLDIER BEAM DESIGN
. Ml =—0.561 kips-ft
MMIt=3.599kips•ft
Mmax�= 3.599kips• ft
lf
Sfeq._ Mmax'S Sreq= 13.087 in3
0.66•Fb
use 2-C10x15.3 Sall= 27in3
Copyright 2005,Schnabel Foundation Company
. �cl���abel Calculation Sheets
FOUNDATTON COMPANY
Project: Vail Froqt Door il Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: 2� /yL
Owner: VRDC Date: December 28,2005
Generat Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #2: Soldier Beam 2
Desiqn parameters for a one tier svstem:
H= 17 ft (design height)
H1 =7 ft (depth to tieback row)
S= 10 ft (spacing) �
a =20 deg
TIEBACK DESIGN
B1 =4_913kips
B1•S
DLT1 := DLT1 =52.283kips
cos�a�•1 ft
use 1"� 150ksi bar Lu�= 7ft
La:= 20ft
SOLDIER BEAM DESIGN
M1 =—6.174kips•ft
MMIt=2.154kips•ft
M�:= 6.174kips•��
Mm� S S 22.451 in3
�req�— 0.66•Fb 1e9
use 2-C10x15.3 Sall�= 27in3
Copyright 2005,Schnabel Foundation Company
. Scl�un�abe� Ca[culation Sheets
FOUI\'DATTON OO:�ff'A,NY
Project: Vaif Fro�t Door Il Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: 2�LyL
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #3: Soldier Beams 3-4
Desiqn parameters for a one tier svstem:
H=20 ft (design height)
Hl = 10 ft (depth to tieback row)
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B1 = 8 kips
B1•S
DLTI := DLT1 =85.134kips
cos�a�•1 ft
use 1-1/4"� 150ksi bar Lu'= �fr
La:= 20ft
SOLDIER BEAM DESIGN
Ml =—16333 kips-ft
MMlt=—0333 kips•ft
Mm�= 16:333kips•�
Sreq:= Mm�S Sreq=59393 in3
0.66•Fb
use 2-W14x26 Sa��:— 70.6in3
Copyright 2005,Schnabel Foundation Company
. Sc1�un�abel Calculation Sheets
FOUNDATION COyII'ANl'
Project: Vail Fro�at Door�I Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: 29/yz
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #4: Soldier Beam 5
Desiqn parameters for a one tier system:
H=20ft (design height)
Hprime=2g•Z ft �surcharge factored height,see surcharge explaination next page)
H 1 = 10 ft (depth to tieback row)
S= 10 ft (spacing)
a =20 deg
- TIEBACK DESIGN
B1 = 11.28kips
Bl•S
DLTI := DLTI = 120.039 kips
cos�a�•1 ft
use 1-3/8"� 150ksi bar Lu'= �fr
La:= 25ft
SOLDIER BEAM DESIGN
M1 =-23.03kips•ft
MMI t=—0.47 kips•ft
Mm�:= 23.031dps•ft
If
M�S S 83.745 in3
�e9� 0.66•Fb req=
use 2-W14x30 Sa��:= 84in3
Copyright 2005,Schnabef Foundation Company
. �C]�'�"'��^ �� Calculation Sheets
FOLTV`Ur�.TION CQ�II'AI�'}i
Project: Vail Front Door ii Contract No.: 07-37i5
Location:Vaii,CO. Sheet No.: 30/yZ
Owner: VRDC Date: Dec.28,2005
General Contractor: Hyder Construction,Inc.
Soldier Beam 5
VAIL FRONT DOOR II
Lodge at Valt Surcharge
DEPTH(f(7 0 1 I J 4 5 Pressure(t.0E-01 ksQ
0
0.313
0 4246
' M�t.
0.3864
5
0.3042
/
�2273
0 1679
�0 0.1247
/0 0938
0.0717
Y5 OA557
Max.Pressure:�.425 ks!
u+U •��am:=3.s n
<LOres> CopyryM by C1VlLTECHSOFTWARE Te1425-45Jfi488 Fax425-d53s848 wwwdvtttech.com
Licensed to C Ba�er Schnabel Foundation
Date&Time: 1?120/2005 11:39:20 AM File Name:
The Height of Wal1:=15
Flexible Wall—The wall is pertectly flexible,or the surcharge load is applied before the wall is costructed.
Max.Pressure:=0.425(ks� at depth:=3.3(ft)
The shoring in this location wi11 be adjacent to the southwest corner of the Lodge at Vail.
To calculate the surcharge load on the shoring, the existing building was modeled as a 3'
wide strip load located 4'-3"behind the shoring line. It is assumed to be supporting a
load of Sksf bearing 15' above subgrade. The computer program used in the design is .
LPRES by Civiltech Software.
Total lateral load imposed above subgrade: 3.25 kips/lf
. � "L'����'��el Calculation Sheets
FOiJI�TDATI01\' COMPANY
Project: Vail Fro�t Door II Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: ��/yz
Owner: VRDC Date: December 28, 2005
Generat Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #5: Soidier Beams 6-10
Desiqn parameters for a one tier svstem:
H= 16 ft (design height)
Hprime=31.4 ft (surcharge factored height,see surcharge explaination next page)
H 1 = 10 ft (depth to tieback row)
S=5.167 ft (spacing)
a =20 deg
TIEBACK DESIGN
BI = 13397kips
B1•S
DLT1 := DLTI =73.667kips
cos�a�•1 ft
use 1"� 150ksi bar L�'- Sft
La:= 20ft
SOLDIER BEAM DESIGN
M1 =-28.03kips•ft
MMIt= 1.451kips-ft
Mmax:= 28.03kips.ft
lf
Sie4:= Mm�S Sr�=52.666 in3
0.66•Fb
use 2-W14x22 Sa��:= 54in3
Copyright 2005,Schnabet Foundation Company
�C��',�'���� Calculation Sheets
FOL1�'DATTOI� CO�II'�?7i'
Project: Vail Front Door II Contract No.: 07-3715
Lceation:Vail,CO. Sheet No.: 2 yZ
Owner: VRDC Date: Dec.28,2005
General Contractor: Hyder Construction, Inc.
Soldier Bea.ms 6-10
VAIL FRONT DOOR II
Lodge at Va!!Surcharge
DEPTH(fq 0 1 2 3 4 6 Pressure(i.0E-0f ksQ
0 •
0.2a59
0.3913
M� 0.425
/
0.3912
S
0.3323
02776
02184
0.7748
�0 0.1403
0.1133
htax.Pressure=0.4752 ksf
Z(�U at depth=J.1 ft
<Lprcs>CopyrigM by CIVILTECHSOFTWARE Te1425-I33-6488 Fax4I5-03JSB.fB www.clviltech.com
Licensed to C Baxter Schnabel Foundation
Date 8 Time: 1 J20l2005 11:40:14 AM File Name:
The Height of Wall:=11
Flexible Wall—The vraA is pertectly flexible,or the surcharge load is applied before the v✓ait is costructed.
Max.Pressure:=0.4252(ksn atdepth=3.1(ft)
The shoring in this location will be adjacent to the southwest corner of the Lodge at Vail.
To calculate the surcharge Ioad on the shoring,the existing building was modeled as a 3'
wide strip load located 4'-3"behind the shoring line. It is assumed to be supporting a
load of Sksf bearing 11' above subgrade. The computer program used in the design is
LPRES by Civiltech Sof�ware.
Total lateral load imposed above subgrade: 2.93 kips/lf
. Scl�ur�a.bel Calculation Sheets
FOUNDAT[C)N COMPANY
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: 'i3/yZ
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #6: Soldier Beams 11-14
Desiqn parameters for a one tier svstem:
H= 16 ft (design height)
Hprime= 1936 ft surcharge factored height,see surcharge explaination next page)
Hl = l Oft (depth to tieback row) '
S=9 ft (spacing)
a =20 deg
TIEBACK DESIGN
B 1 =8.26 kips
Bl�S
DLT1 := DLT1 =.79.114 kips
cos�a�•1 ft
use 1-1/4"� 150ksi bar Lu:= Sft
La:= 20ft
SOLDIER BEAM DESIGN
MI =—17.282 kips•ft
MMIt=0.895kips-ft
Mm�:= 17.282kips. �
lf
Sreg:= Mm�S Siey=56.559 in3
0.66•Fb
use 2-W14x26 Sall�_ ��•6�n3
Copyright 2005,Schnabel Foundatlon Company
����"���e� Calculation Sheets
FOtJti'DATIO\ CO�fI>,�-1.Ir'X
Project: Vail Front Door II Contract No.• 07-3715
Location:Vail,CO. Sheet No.: 3N�Nz
Owner. VRDC Date: Dea 28,2005
General Contractor: Hyder Construction, Inc.
Soldier Beams 11-14
VAIL FRONT DOOR II
Lodge at VaT!Surcharge
DEPTH(ttJ 0 1 1 3 4 S Presst�re(1.0E-01 ksry �
0
0.0445
0.0824
0.1093
0.1242
s
Mau. 0.1288 � �
0.1257
0.116
OJ077
�Q 0.0966
OA857
Max.Presture:O.JT88ksI
Z(� at depth.—�.S M
<Lpiss> Copyd�M Dy C(VILTECHSOFTW,qRE Te/4I5d53-6I88 FeX426-4535848 xaw.tlViheeheom
Licensed to C Baxter Schnabel Foundation
Date 8 Time: 12/20/2005 11:46:51 AM Fle Name:
The Height of Wall:=11
Flebble WaN—The waq is perfecty flexible,or the surcharge load is appl'�ed before the wall is costructed.
Max.Preswre=0.1288(ks� at depth:=5.5(ft)
The shoring in this location will be adjacent to the southwest corner of the Lodge at Vail.
To calculate the surcharge load on the shoring,the existing building was modeled as a 3'
wide strip load located 8'-4"behind the shoring line. It is assumed to be supporting a
load of Sksf bearing 11' above subgrade. The computer program used in the design is
LPRES by Civiltech Sofiware.
Total lateral load imposed above subgrade: 1.08 kips/]f
sC�����e1 Calculation Sheets
` FOLJNDATION CO�II'A.NY
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: 35 /'�Z
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #7: Soldier Beams 15-26
Desiqn parameters for a one tier svstem:
H= 16 ft (design height)
Hprime= �6.8 ft (surcharge factored height,see surcharge exptaination next page} �
H 1 = 10 ft (depth to tieback row) .
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B1 =7.168kips
B1•S
DLTI := DLT1 =76.28kips
cos�a�•1 ft
use 1-1/4"� 150ksi bar L�:— Sft
La:= 20ft
SOLDiER BEAM DESIGN
M1 =—14.997kips•ft
MMIi=0.777kips•ft
Mmax�= 14.997kips•�
If
Mmax'S
S�=54.535 in3
S1eq�— 0.66•Fb r
use 2-W14x22 3
Sa11== 54in
{w/in 5%,O.K.)
Copyright 2005,Schnabel Foundation Company
�c�ur:iabel Caiculation Sheets
FOUNDATION CO�iPA1�TY
Project: Vail Fro�t Door il Contract No.: 07-3715
Cocation: North/East Waf!Shoring-Lodge at Vail Sheet No.: i`/yz
Owner: VRDC Date: December 28,2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #8: Soldier Beams 27-32
Desiqn parameters for a one tier svstem:
H= 16 ft (design height)
Hprime= 16.8 ft (surcharge factored height, see surcharge explaination next page)
H1 =7 ft (depth to tieback row) •
S= 10 ft (spacing)
a =20 deg
TIEBACK DESIGN
B 1 =4.779 kips
B1•S
DLT1 := DLT1 =50.854kips
cos�a�•1 ft
use 1"� 150ksi bar Lu�= Sft
La:= 20ft
SOLDIER BEAM DESIGN
M] _—6303kips•ft
MMIt= 1.201 kips•ft
M�X:= 6303kips-fr
lf
Mmax'S
Sreq:= Sreq=22.92 in3
0.66•Fb
use 2-C10x15.3 Sa��;= 2'7in3
Copyright 2005,Schnabel Foundation Company
��,����� Calculation Sheets
POLT��ATTOIv Coi1II',�'1.��'X
Project: Vail Front Door!I Contract No.: 07-3715
Location:Vail,CO. Sheet No.: ��/yz
Owner: VRDC Date: Dec.28,2005
General Contractor: Hyder Construction, Inc.
Soldier Beams 15-32
VAIL FRONT DOOR II
Lodge at YaU Surcharge
DEPTH(I{i 0 t 2 3 4 5 Prsssur�(1.0E-07 ksQ �
0
0.0106
0.0196
0.0266
0.0309
b \
0.0327
Mac.
0.0326 '
0.0312
0.0297
�Q 0.0265
/
' 0.0239
� ef depU�iS��9�.0J29.ksi
<Lpres> CopyrlgM by ClVILTECH SOFTWARE Tel425-453�d8B Fax425�53SB48 wNw.elvlttechcom
Licensed to C Baxter Schnabel Foundation
Date 8 Time: 12120/2D05 11:48:10 AM File Name:
The Height of Wall:=11
FlexiWe Wall—The wafl is pertectly flexible,or the surcharge load is applied betore the wall is costructed.
Max.Pressure:=0.0329�ks� at depth:=5.9(ft)
The shoring in this location will be adjacent to the southwest corner of the Lodge at Vail.
To calculate the surcharge load on the shoring,the existing building was modeled as a 3'
wide strip load located 9'-0"behind the shoring line. It is assumed to be supporting a
load of 1.Sksf bearing 11' above subgrade. The computer program used in the design is
LPRES by Civiltech Sofiware.
Total lateral load imposed above subgrade: 0.28 kips/If
�cl�ur:�abel �alcutation S�heets
� �'OUNDATiOiV CO�II'Al�'Y
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wall Shoring- Lodge at Vaii Sheet No.: 1� /yz
Owner: VRDC Date: December 28,2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #9: Soldier Beam 33A (cantilevered)
DesiQn parameters for a cantilevered svstem'
H= 22 ft (design heighf) Pa=0.034��ps P =0.4 kips
P
fc3 ft3
S= 10 ft (spacing)
SOLDIER BEAM DESIGN
Mm�= 173.333 kips•ft
Mm�
Sreq�= SCeq=63.03in3
0.66•Fb
use W14x48 Sa��:= 70.3in3
L,m�n=24 ft
Copyright 2005,Schnabel Foundation Company
.
�C��`���e1 Calcula#ion Sheets
FOUNDATTOIV COMPANY
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wall Shoring-Lodge at Vail Sheet No.: s9 /yz
Owner: VRDC Date: December 28, 2005
General Gontractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #10: Soldier Beams 33-34
Desiqn parameters for a two tier svstem:
H=28 ft (design height)
H1 =7 ft (depth to tieback row 1) -
H2= I 1 ft (distance from tieback row 1 to row 2) '
S= ]0 ft (spacing)
a� =20deg
a2= lOdeg TIEBACK DESIGN
B 1 =7.434 kips
BI-S
DLTI := DLTI =79.115 kips
cos�a I�•1 ft
use 1-1/4"� 150ksi bar L,,:= 12ft
B2=634 kips La:= 20ft
BZ•S
DLT2:= DLT2 =64375 kips
cos�a2�•1 ft
. use 1"� 150ksi bar Lu'= ��
La:= 20ft
SOLDIER BEAM DESIGN
M1 =—7.089kips•ft
MMI =734kips•ft
MM2 =7.016 kips•ft
Mm�:= 734kips•ft
If
Mmax'S
Sieq� 0.66�Fb Sreq=26.691 in3
use 2-C10x15.3 Sa��;= 27in3
Copyright 2005,Schnabel Founda6on Company
•
Sc�ur�abel Calculation Sheets
• FOUNDATTOI�' C0:1�II>�Iy
Project: Vail Front Door II Contract No.: 07-3715
Location: North/�ast Wali Shoring-Lodge at Vail �heet No.: yo/yz
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction Inc. By: CHB
Rev. By: JAF
Case #11: Soldier Beams 35-37
Dzsiqn parameters for a t��ro tier system�
H=30 ft (design height)
H1 = 7.Sft (depth to tieback row i) .
H2 = 11.5 ft (distance from tieback row 1 to row 2) .
S= 10 ft (spacing)
a� =20 de�
a2= lOdeg TIEBACK DESIGN
B1 =8.446kips
B1•S
DLT1 := DLT1 =89.877kips
cos�a 1�•1 ft
use 1-1/4"� 150ksi bar Lu:= 12ft
B2=727 kips La:= 20ft
B2•S
DLT2:= DLT2=73.824 kips
cos�a2�-I ft
use 1"� 150ksi bar Lu�_ �fr
La:= 20ft
SOLDIER BEAM DESIGN
MI =-8.719kips•ft
Mld 1 = 8.422 kips•ft
MM2 = 9.205kips•ft
Mmax�= 9.205kips•ft
lf
Mm�•S
Sr�� 0.66•Fb Sre9=33.473 in3
use 2-C12x20.7 3
sall�= 43in
Copyright 2005,Schnabel Foundation Company
r
� �c�u�:�abel Calcula#ion Sheets
.
FOUItiTDATI01�? CO:��IPAI�iy
Project: Vail Front Door II Contract No.: 07-3715
Location: North/East Wafl Shoring- Lodge at Vail Sheet No.: y�/��z
Owner: VRDC Date: December 28, 2005
General Contractor: Hyder Construction lnc. By: CHB
Rev. By: JAF
Case #12: Sotdier Beams 38-39
Desiqn parameters for a two tier svstem�
H=37 ft (design height)
Hl =9.275 ft (depth to tieback row 1)
H2 = 14.413 ft (distance from tieback row 1 to row 2) �
S= lOft (spacing)
a� =20 deg
a2= 10 deg TIEBACK DESIGN
B 1 = 12.967 kips
DLTl :— B1•S DLT1 = 137.99kips
cos�a 1�•lft
use 4-0.6"strand anchar Lu== 12ft
B2= 11.045 kips I-a== 30ft
B2•S
DLT2:= DLT2 = 1]2.153 kips
cos�a2�-1 ft
use 1-1/4"� 150ksi bar Lu�_ ��
La:= 25ft
SOLDIER BEAM DESIGN
M1 =-16.485kips•ft
MM1 = 16.485kips•ft
I�I�i2 = 1u.485kips�ft
Mmax�= 16.485kips• ft
lf
Mmax'S
� SCeq= Sreq=59.945 in3
0.66•Fb
use 2-W14x26 S — 70.6in3
all�—
Copyright 2005,Schnabel Foundation Company
�C������1 Calcula#ion Sheets
• FOUNDATTOIV COMPAN�'
t
Project: Vail Front Door II Contract No.: 07-3715
Location: No�th/East Wall Shoring-Lodge at Vail Sheet No.: uz/�cz.
Owner: VRDC Date: December 28,2005
General Contractor: Hyder Construction fnc. By: CHB
Rev. By: JAF
Case #13: Soldier Beams 40-48
Desiqn parameters for a two tier system�
H=40ft (design height)
H1 = 10.027 ft (depth to tieback row 1)
H2= 15.582 ft (distance from tieback row 1 to row 2) �
S= 10 ft (spacing)
a I =20 deg
a2= IOdeg TIEBACK DESIGN
B1 = 15.155kips
DLTI :- BI•S DLTl = 161.274kips
cos�a 1�•1 ft
use 5-0.6"strand anchor L�'- 12ft
B2= 12.909kips I-a�= 35ft
DLT2:= B2 S DLT2 = l 31.077 kips
cos�a2�•1 ft
use 4-0.6"strand anchor Lu= 7ft
La= 30ft
SOLDIER BEAM DESIGN
M1 =-20.829kips•ft
MM1 =20.829kips•ft
MM2 =20.829 kips-ft
MmyX:= 20.829kips•�
lf
Mmax"s
Sreq�= Sr�=75.742 in3
0.66•Fb
use 2-W14x30 ���;_ gq�n3
Copyright 2005,Schnabel Foundation Company
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 11/16/2006
Legal Description: � ��-S--b� _ b0 2� Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115.18 108, 815$12, 533,311.70
Totals. . . 108, 815$27, 739, 000. 00*
Fireplace Information: Restricted: #of Gas Appliances: 0 !f of Gas Logs: 0 #of Wood Pellet: 0
***********************************�********� ********************** FEE SUMMARY ************************************************************
Building------> 10 3,2 0 6.l0 Restu rant Plan Review--> $o.0 0 Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 103,206.10 Recrea ion Fee--------------> $0.00 Additional Fees-----------> $0.00
Investigation-> $o.0 o TOT L FEES-------------> 2 0 6,415.2 0 Total Peraut Fee----------> 2 0 6,415.2 0
Will Call-----> $3.00 Payments-------------------> 206,415.20
BALANCE DUE---------> $0.00
*****************m*******�***************************************�*********************************************�**********�****�*****************
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading,
Excavation and
Shoring only. Other approvals required prior to approval of full building permit.
PW approval
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/il/2006 MROYER Action: AP Full building permit pending conditions
and other
department sign-offs.
11/13/2006 mroyer Action: AP footing revision for crane #1
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for
excavation,
shoring and grading only. Addtional approvals required for building permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/14/2006 George Action: AP
08/24/2006 George Action: AP
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and
excavation only.
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated
received
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
Item: 05550 ENGINEERING CIVILS
****************�:****************************************************************************�******�**�:********�*************************�***+*�
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to.comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
r'-`°-�--
SIGNATURE OF OWNER Q 'CONTRACT F AND OWNEF
C�� �
PAGE 2
*�kx�**�**�*�k�**�*�*:x*�*�*�:*�:�x*�:******�:*�x*�:*:x*�*�k�*�*��*�:*�x*�x��**�x*><*�x��x�:*�k*�x*�x*:x*�x*:x*�x*���***�x*�x*�**�x*�x*�:
CONDITIONS OF APPROVA.L
Permit# B06-0018 as of 11-16-2006 Status: ISSUED
�x**�*�x**�x*�x**�x*�x*�x*:x*�x**�x:*x:�:*�x**�x***�x�x***��:��:*�x***�*�**�*�*=x�*�x*><*�x*�x*�x�*�x*�:*�:*�x*�*�***��x*�x���*�**�x*�x*�
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 11/16/2006
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTtfRE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
**********************************************************��**�***��***********+****�**�****
TOWN OF VAIL, COLORADO Statement
**********************************�******************�*********:�********�x*******************
Statement Number: R060001988 Amount: $548.00 11/16/200612:10 PM
Payment Method: Check Init: LC
Notation: #2350/Doug
Thompson
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW CONIM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 206,415.20
This Payment: $548.00 Total ALL Pmts: 206,415.20
Balance: $0.00
****+**********�x*�**********�:**�x********************************+***************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 292.00
PF 00100003112300 PLAN CHECK FEES -82,280.08
PF 00100003112300, PLAN CK - project GFP012 82,536.08
-----------------------------------------------------------------------------
u
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Building Permit#:� —Q7��
#.; �� � �� � 97t?-479-21x49(tnspection�)
��'����� � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
GQ¢r C�nSti- �-s> ln IOc(/-� C� �rr � S— �
ATTENTION: , JR,CHARLIE,GREG,CHRIS
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel,# ����o�2Zl o�-�Z
Job Name: v��,s ��n+ �'c� � � JobAddress: 15� v�.;� �,�
�or J
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: U�;� ���,� Address: Phone:
Architect/Designer: ��yo Address: Phone:
Engineer:i►�,�,�,�.��,�� Address: Phone:
REASON FOR REVISIONS: (�n��;,�,,�,�( ,�a..�,',�
Work Class: New� Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
FOR OFFICE USE ONLY
OfheF Fees.� � ��- Occupancy Group: ��� -� �1cce ted B ;�
Type of Construction: � Date Received:
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
TOWN OF VAIL DEPARTMENT OF CONIMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL,CO 81657
970-479-2138
�S�g Q� NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERNIIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied. . : 02/10/2006
Parcel No...: 210108278002 Issued. . : 06/O1/2006
Legal Description: � Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-8'1.5-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,659,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOP�.DING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
Totals. . . $27, 659, 000.00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
**+t***t***�*******�*s*a*�*�***�****a**�************s**+�*****+***** FEE S UMMARY �*******�**a*��:****+*t**t***r************+*s**********+***�*
Building------> 102,914.10 Restuarant Plan Review--> $0.00 Total Calculated Fees---> 205,831.20
Plan Check---> 102,914.10 Recreation Fee--------------> $0.oo Additional Fees-----------> $36.00
Investigation-> $0.00 TOTAL FEES-------------> 205,831.20 Total Permit Fee----------> 205,867.20
Will Call-----> $3.00 Payments-------------------> 205,867.20
BALANCE DUE---------> $0.00
*******�****+asa*r**�*s*�*+**�+*�**********t*t*******t*a****s��********r*********+***aa***+**s*+*+****************�*a*+***+***t*r:******r****�****
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading, Excavation
Shoring only. Otner approvals required prior to approval of full buil�ding perm t.
t �J� \°�
G�` �'���
�
_..Y�
�, :.
� r
Monroe 8�Newell
Engineers,I�x.
Structural Engineers
vaa.[w�K.•r.�
Field Report
Vail's Front Door
Building A - Parking Garage
Report#: 5
Date/Time: 10/24/O6 12:00 PM
Weather: Sunny 50 degrees
The purpose of this site visit was:
to obse�ve rebar for tower crane#1 footing,which is located near grids 30 and L.3.
The following was noted:
Reference sheet S101 W. No exceptions were noted. Rebar was placed as shown on drawings.
Report Prepared by:
Gre Leuchtmann �
REV_IEWED BY
c�c�;�,� u � .,�
DB
Nov t 3 2000
COLORAAGENCY ECTION
VAILS FRONT DOOR BA� E R
SUBMITTAL DATA SHEET c:; �, : .� E�
� ,__„�:� ss�,f�
PROJECT NAME: VAILS FRONT DOOR A/E'S PROJECT NO.: 210-001-00
OWNER: Vail Resorts Development Co.
Avon, Colorado BAKER PROJECT NO. 8963
FIRST SUBMITTAL DATE: 9/7/2006
RESUBMISSION DATE: 11/7/2006
ARCHITECT: 42/40 ENGINEER:Monroe 8 Newell
1621 18th Street Suite 200 70 Benchmark Road Suite 204
Denver,Colorado 80202 Avon,Colorado 81620
Ph: Ph:
Fax: Fax:
GENERAL CONTRACTOR Hyder Construction Compan� SUBCONTRACTOR:Baker Concrete Construction,Inc
1904 Jasper Street
Denver,CO 80202 Aurora,CO 80011
ph; Ph: 303-367-8111
Fax: Fax:303-367-8004
SPEC.SECTION: MANUFACTURER/SUPPLIER:
ITEM SUBMITTED: BLDG E TOWER CRANE DESIGN CALCULATION;
DEVIATION FROM
CONTRACT DOCUMENT Meets Specification
BAKER SUBMITTAL NO.: 3300-004B
��.�._._������`�� RE��E1►'�c�D E3Y
BAKER CONCR�TE C�NST�UCTION � ���
NQV � 7t?s��� ,°�, ?
�� a � 8nd h�r cubmi a � —__�--�
Bake�Con�r�oi�n�t�4u�na�w���„Ga, , r������tir�a i�vsp�cri���n�
theatte dlnt,tx�td�q�w�t�tneCont�+m�ts,� eto�u ° �.__.__..__� �'u��:�;��
co�rtrador ena piler ntr�tor b arcon� .__._ ___.._._.___
�pn pro• ��
firmationan correlatP�noi�i��io����t� wo �thwotK
cessesandamstNCtio teca�, � t ,;a����ot tbe wark.
ofothestrades;an�sa��st_ -- ---, �� `;',���?�
.____.-----
� ��,,���
�z 1,�� �
d
� � � � � � � i
��� �� 2006 I
J
TOWN OI= '1fA�L
.����.
, , ��
��
�„�;
��.u...�,.�;:.
R�CEIVED
Tower Crane Design Calculations Nov o s Zoos
�►:
eaker concx�e Ccx�,
Date: August 9, 2006
Project Name: Vaii's Front Door 2006
BCCI Job Number: 8963
Project Location: Vail, Colorado
Structural EOR: Monroe and Newell Engineers, Inc.
Architect: 42/40 Architecture
General Contractor: Hyder Construction, Inc.
.�.�
�
��� �����4�.y
` (���4 oaea�@s+�r�y 6,f,'°°
r� v �c+ � ��i'fs �,r°� `t,`�
v�� fl �. 'S.d"( B4 /�•.'h�4�t
��� ���' ��•"� r�.7}
•�` �,��" '�'1
F���'i E���E� �Y :� :���� �� ��<
e� - �
� �� G��+� ':�,�;.
�3 0 oa .y,�V
�� �
�
� ��o�ae:om°,1�,, �
� , �`S'�f"U���, �`��'`
-�'�. �
CO�OI;ADO {NSPECTION ��
A6E�1CY � � ��v�
�
George A. Amolochitis, P.E.
Equal Opportunity Employer
Southwest Region Corporate and Midwest Region
8300 Heampstead Road 900 North Garver Road
Houston,Texas 77008 Monroe,Ohio 45050-1277
713-864-0657(OFF) 513-539-4000(OFF)
713-864-6783(FAX) 513-539-4380(FAX)
Southwest Region C o n c r et e JOB U��V`� �' ++�� �"o'��
s3oo Hempstead Street C o n st r u c t i o n ITEM Tot�.�- ��+-��- �bu�'�- �+�'
'iouston,Texas 77008 �-
713-864-0657(OFF) DATE '��8� m� SHEET NO. � OF
713-864-6783(FAX) "('�,� � ��t �
i W
_ , C � � _ . . .. � _ _ _
`�',�✓1rt'"�- � .��'I'S f ���X_. 1�w�.�S �a�s t or- , � '
+_ � . _:._r..�__._ �e_ N._,._... ..... .__ ---w;�.��._.____�__--.- .-._�- .. _
< , __ _ , ... � . _, _ _ __
�''4l.,�_ _'����{a ti �1�c"�� ..��D(Z° i �'!� 9G "���'L�2-,..� �- � 1'��� ?,.� �i . �1°-��-r�z�
_ , _
' ��° .,.:=����.. � c�,►Y=n F-' �'z-�`��1� _
, ';�..r�kkc�� ' �.,�tYra-� ', ,
, _. ,_....__.._._ .....
�h��i� �a�� �M��l _ _5��2 I�• _�� __ S��:S .k , �- _,_ _
� �.. ._.__�:..���:�
V�-�1c.�., �?.r,u.�. CN� . 3�� .K . _ � �o� �.}�1�!;���. ,��� �`1�_ . �
¢ �
.� � �
L_� -�1:, r�,_c� ��? ___. . __ l_( � ;__ _ �� � _ _ � ._ �
��
I����►.n�..__�cz�-�: . ��±� ___ �1��� __ ; `� k _< < . � _ '
' -- �� k- � `
C;oM�,���� , �e� �fl� __ . � �_ ' .�`�►� _
�''�p�` . __�� �� _ _ 4 8� ►� ��� - - _� __
' "� � � �'� ;�.; '�. �� -� ' ,
„,, C ��f �:,T �ta
O�h�
___ __ , r. �
_ ; __ , __ _ _ . ,_ _ /' _ ,
`� � . 4�...�'+��"4 �';t�.� t _,Irs t r�.�..J�c-i., �.,b _ , '�.r? ��;:hfcr...-�
_ A�� �'t .
��
(.... , .M_ � �;�.,,� . �. ��, C�,?`'>Q
I`1 I�K ►,I J w � `�P .�.�� �._ �d?�0 f� � _
�14��c t��. ,_A ZS�jr_2�i�.�_.�� �xin��a?�;'�,�.. ��frf L� ' ,
. _ _ . __ .
��C�t1,F �� � f1F .�?���.�� ^_ ��x 2� � �_ ��O, ,► � ` ��'a, �� �1 P�
�
, ,
;_ . j�'�,�_�� 'r� V�--Cru�.- _'��, �� -� ��,�,� �, -I��. ']j ��'
_ , � � � � _ _ _� ,
+ 1
:�',� � -''�, '� .- �� � ��� � � ;�� �� ,���
� �. -r— - -�____ , I�'� 3�" ��s � ��,� �.
_ ; �._ ,� �. _ � � l��+'= _ , __ _ , _ -�-
_ � _ � . _ ,
'�1���.,`( �� . ����(� �:.— J�n�� -� 2 S x � ' ��7� ��c. ��,
_ ' _ __ ._ � - -- ----�..W.�.
_ __ �_
�fT�t ti�, �t�r`'� � �G .�.���-'�` �'�. ' � �
� F - •
__ `��4�-'� , __U��'!`C . _ __ j . M y �� _.
, i ; o
�
_ _ � � � _ �_,: � �, y
� — �7�� ��,.. �.� � , i
' �a N
_ ___ . � { � � _ ,
�. . � I
_ �l ''. __ , ,_ _. i_ .
'� _. '�2 '�`� �!'�, : �
,
�, , _
_ ,. :
, _ _ _ _ __ ; . • ;
, _:�____,�.a�_ _
I ' �- j'---�--� '4,��
i. _.. _ _ _
i ; i ; �; : I ! � �,�` r .. ._ u.�...j,,..�
�ti
Form 236
Southwest Region Ci O n c r et e ,JQg ��:�Lt� ?"�?�t�T ��
R300 Hempstead Street C o n st r u c t i o n ITEM �o�t,�iz �-v�r-�C� `�r*n!�`�1.�r--�''
Houston,Texas 77008
713-864-0657(OFF) DATE �I i�i�u� SHEET NO. "y OF
713-864-6783(FAX) �� s�- Q�2,
I /
, _
_ ; __ . _
, . �V tj� �7��1``./ �1�/"1" � , �..'�f✓�'1... V�'�_ '�r,.,.Sl,t; F=�`�' _r.
� , __ , 3.23 _ '��7g ;_ ___ ; � k_ � �
� '
� �� �� — �- `�`�3,� -� ��� � — 3��
� y �- -�- ��_v � _ ._ _� _ _
� .
_ , _ _
Ov�''� G��.��. �a.;�.,� l�r�, _��1*r �rr;�L r� - . _ _
. _ . __ � _ _ ; _ .
. ^
��7 „�.. �� / (7 ! '� ��l 7 � � `�' � �
� _._ g __:-- --�-- -- '� I , _
� � p _ ��
� �- -_ � � � � �
-� -�r � _ _
__ _ .
_
_
� �Ea x_ ������� �a� �� �ar���, wtu�.� �
_ � _. _ ;_ , _
_ �.
� +R-I+a� . . ��o� .`E' ,__�- ,����k'��2� ���� �',�5� � , sS � � ,?SI ^ � �4t�S
__ _. _ _ .
�
;
u�e ��aL. : ��t�� _
_ � _ . .
_ _ . __ _ : . _. _
, �
N���
_ ���� `���� ��
_s ,�, _
.� ,
� � ._ � ___ .
�
�� ��
. _ . �'C6��b� _
� � ,��� , QZ� � -. ,�-- � 2� = �-�� }a�'
� , _ . _ _ - _ ,
N; ` ,
'.� � _. _ _ , __ . _.
� `,��_____�_/ 1 ��- . �� ;=� �. �� � i°"l.oasr - �'� . .
! � ; � , � , � , , �
_ _.
, .�
__ __
! �4' ��N �.' . ; �' �. �, � �'s' �.�-�d ,_ _ �2�, ` > ��� � o�
��-y ' , �a,A, Y ' �.._�-_—_�---__..�__-----
__ _ . __ _ . _ _
—�� _ �"C��-- ._
_ :._� t '�''� � �._(�a�:__' �✓- �I'' �� '��" u '�"�-
�
, , �__.., �__..._._ ' ,_
__ _. = :._ __ , �
1n S �G���1� ��,,�.
a __._ . _ (3 j E3 , ._. .
� . .. __
�_. i � ' �,'� C�-' �a�.. _ �?'�-�.,�;�'.. _
r_ , _ ._ { _ _ ._
�
� _ { �, �
_ .-�--__ ._-_-�-_ . -
__ _
_
. F�E����►�!��
, � F�
_� _ '; _ __f�i� _ . ____ ..__ . ; _ __
;
;� _._ ___�_ � ,
_ ,_ __ __ ,
, � ,..
� i'''b
' . : .._._._... ,_..... ._ . ............ ....... �:- . _........ ..._ . C�'1 II`d - ...... .... ..
_ ,_ �AAGEPv SY EC
itG N
�o�o�.
Form 236
Southwest Region C+o n c r et e ,JQB ��1t.s S �`� �°��
R300 Hempstead Street C o n st r u c t i o n ITEM �1��'� �-�"� �ocJ�t�rbATt2�►J
douston,Texas 77008
713-864-0657(OFF) DATE a� $���a SHEET NO. 3 OF
713-864-6783(FAX) ��� � 8C��?�
t
__ . , � ;,r ' �
�! TL�'� l�� � SF�'��- "° ��G�- :-' 1, � �G �p
, . _ _. K
'
,_ '�� =. 2`� 2 - : � �fo)�6� � �a�- _��`� _ y � � , 2? ,�. �C 22,�'h�
: , ; ; z �u.; :
. _ _ __ . _ _ . _
_ ' �j. _�, � 22;�.� �-- �c,.�� ;�-- � ��j I . fd ��
o ,
' , ,
� ���,���- �c� ��a� _ .- , _
,�V�_-- g, � _,___.__ -__ - .� 2�I I. $ x' S�- � ����a ��c
,_ . _ . ��-��;-� _ .. ___ .� .__ . _ ; _ _
_ _ . _ _ . _ _ _. _
11 � .� I, � X �a_3 � = BS��. l . �° � �`'�u � ��
� _ � _ . _ �
�'k-'� �t���,,' v��`T �.{�4'v-'1k!fL !'.. _ . _� Y C.�-� � � `
2 `
"� 4 1rJ
�—i
_� �Sx�x������ _ ___ _ _
�. _
_ �
` U � 2�x �� � 5�- -
G „ .,._____�� .._._
; . �t�7;� .
, E �f�� ��-., � _
M oM G,� �./k��c.,��`C _ oF� `(IK. F�?pT�.�!�'►
_._..__�_ _
_ _.
, ._�_� ._.._�__�,________ _ ��O�yi �
, _ . , . � �
�f�Tt�A�_ .5����a�� :�tZ_,�a►.�-� �.t u,� R,�. ; .
_ ___ ��L�F„`�C30 N��FECTION
: ; : I' AGEN�.:,Y
_ —
_�_�_�__�_��� �� �.�t 1s ,� � .oc, � �.0�
�I �� , �._ ; �2� ;,sc 2� '_
__� �__...... _�.m.�.,:...��:—.. _ __� _ , _ __ _ _ ; `
� ; �.
�. l�,� -� 1�2� ►� ,�-�k x; l �� = ���� ._� �� ��
__. _
, ,
_.� .M,.. .. .� _. .�_ _�_.. , _
� j� �a-� ,U ���. _ �.���.c� +��.,
�.�,��....�� . � -___�-�.. . _,,.�..�._..
S .o� _ �,°!_ ��.a�x,tz� 5�" .. '
� �k•^a��
: , �.�t�' ',. �_ _ , _. ,.
__ <_ . �.;f �,00�S __
� P � �.ob,�
_ . _ �`� _ ►..��� __ _
� _ _ � _ _
� �St+�,�,� :.. fl , ;o�I S x �o x..f�' ` I�.�`� �•J�,��T
_ _ . _ �
� '.U� .�`�=_lo ���.� � 12u:c�.t� . �< �� � �� _- _�� z`� ������ _ �k� __
;
Form 236
�
Southwest Region C o n c r et e JOB ��0�'``� -p 1�� ��
g300 Hempstead Street C o n s t r u c t i o n �.,�,p,�{� ���,�.,,p,����
-louston,Texas 77008 ITEM �a�Q.
713-864-0657(OFF) DATE �t � �t� SHEET NO. �' OF .
713-864-6783(FAX) ��� � �p���
UUG�Z- TU2t�tr-�� �slS1�i� �C.�, . ; ' _ ,
,
`., x � �- .���?� � � ��
'���'F ��
_ _ �; _ _ _ __ . _
�` ; . __ '�.�4��:^C��.G�_ ;IJ1�Nl�'(' '�`C ��'����
�, �
, � ,
_ . ,.. , _ . _
! . �'i _ � � 1�� 4�� kx 2i �- � 1�1� �`�3,"i� k�_-�+
._� �
� _�_ ----� �_ �
. �� _. �� _ . _. �
� v
►a-� � 12����� �Z� __ Ca'1'��, 1� _
-- ; __. _ � _
���co� �
_ _ . _ _ __ .
�(��3 � �`� °�`
; ` Cl-1�GC.Y�.___`TQ=-hl�It,�;T� ..OF, _ �a-C���-r.. ��� ��c.�-(�er� , _
�twsR►.-ISµ ,���t�:-�tv�� . ��aet�t.��r�.� , USI� . e4 _ 2 � QA�'L`C_ `F�C-'�o�
_ �
�� �/, p
; _ _ '�. __ _��1�������E1,��� ill��
' � __ . __.____..�__._�,
�' 2, 5 � Sb 3 = �4 132� - le � .�
_ , � �(i�1 _ ,
� '� �
. _� .__ , ____ , __ , , _ '.
.... . ... _ . ... �lir i,'A } .. .. _..
`A� �
i �'�� � . .(�'�'t� �t?� � � '
� . S , _�'a'T��4 .I .=%_ �``�,�,t,� '�_ �00 �.�__
' ' ' CG�C�R 0 PEC?ION
; : __. . . _ . __ .
A� INS
> �.�� ' �3�0�-3�3� x �o �� w �2 ��� �Q�, - _ „ _
�
�F f N�Ef �Y
., '.�--F�«��
_ �
_ . __ �
�oci-('r� l� _ �4�T GN ; <� = vJc�CC�a 1'S! � '� T�P�4''�
,_ ` �°,. ,� 4�..�.�.
_. ��_ u _ �1�3��ZkOC1 L�2�-Ov Lc�rtiGt� �»
, `�,t� ' A la
��M . d'�� r�
; ..�� '"° ,� t�" '1't�i'', �:..f�"C� ..,_.__-- ___-__ ___-____. .
_ ' _. � . _ __ _ _ ; . __ , _ . '
, .�`I� �_ 4Z��c.___
S ' '� � � . '. '�o'CTo t-'� l;F°`f�_ , __ � 2 ' -_
_9 � _ ___ � o
, , !� _.._ .,. � ,, �
�' , _ �'-o �'�Nc.jc i � .�
. � S
� ' � ��..._�_.__ � �._ � f_ � � __
_ � '
, ' � _.. `
:.
� , �"1�IZ" �2�...., -.����°. ..,_. _.. ____-_---�--- k _
�,__. ,
. � _ . _
_ �o� �'� �
. �.
�
, S
�.� �._ �
+- -� _ , , -.. , � a.._-.�.....
, .�._ -�....R�_.�. _._.�._ ... .... . .... ....
, � Mi,.� t.��:'�T�- c,�� !
- , : � � t o �_ 2 0.c. . k��-'� ��
_ _. -
t U 3 t�;�„7 ; t _� €2" ��.. _
� ,�
___. _ . _
;. �'TToM ; L.A?(�� _�! _ �a�' e,,,a�p�
__ a � :
�
Form 236
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 02/OS/2007
Legal Description: Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115.18 108, 815$12, 533, 311.70
Totals. . . 108, 815$27, 739, 000. 00*
Fireplace Information: Restricted: Y N of Gas Appliances: 0 #of Gas Logs: 0 ft of Wood Pellet: 0
**************************�****�*************************�****�***** FEE SUMMARY *******�**********�*�*************a:*�*****��*�***�**�***+***
Building------> 103,206.10 Restuarant Plan Review--> $0.0o Total Calculated Fees---> 206,4i5.20
Plan Check---> 103,2 0 6.10 Recreation Fee--------------> $o.0 0 Additional Fees-----------> $6 0.0 0
Investigation-> $0.0 o TOTAL FEES------------> 2 06,415.2 o Total Permit Fee----------> 2 06,4 7 5.2 0
W ill Cali-----> $3.0 0 Payments-------------------> 2 0 6,4 7 5.2 0
BALANCE DUE--------> $0.00
�****�*��*******************�***********�***********************************************************************��****�*************�****�*****�*
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading,
Excavation and
Shoring only. Other approvals required prior to approval of full building permit.
PW approval
required prior to issuance of partial permit.
06/01/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions
and other
department sign-offs.
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
due $60 .00
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for
excavation,
shoring and grading only. Addtional approvals required for building permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval for the
construction of a
temporary stair to provide emergency egress out of Lodge Tower South. This stair
is temporary
only and shall be removed prior to the issuance of a final CO
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and
excavation only.
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU's.
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated
received
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
Item: 05550 ENGINEERING CIVILS
*************************�*****************�****************�**************************�*****************+�*�******************�**********�*�*�**
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
SIGNATU O OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
PAGE 2
�*�:�x*��x*�*:x*�x*��*�*�x*�*�:*�x*�*�x*�x*�x*�:�*��*�*�:���:�x*�:*�:**�:��*****�:*�x****�:**��:*�*�x*�:��x*�x*�x*�**�**�*����:�x*���
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 02-OS-2007 Status: ISSUED
*�:*�:*�x����x���*�x*��*�*�:*�**��:*�***�*�x***�:*�x*�x**�*�x*�:***�*�x*�:*�x��*�*�*�x��:�x*�*�:*���x*�:*�x*�x*�x*��:*x:*��:*�:�*����
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 02/OS/2007
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARHING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
' � v4. �--� ���� ,� u
___ �...-- ����� -
_ �___._...�.___._ i �—� :�-���-� �s�
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Building Permit#: (3d6-Go��
, Q r .��f � 970-478-2149,(Inspecti,ons)
'' � l7 �
�������� � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
!-�,��- C�rSfi������, z,,.� (v�-/� v �=��ti� -���
ATTENTION: � JR,CHARLIE,GREG,CHRIS
Contractor Signature: ��
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea /e Count Assessors Office at 970-328-8640 or visit www.ea Ie-count .com
Parcel;# � r��G�azrc��}
Job Name: UU: �s ����t ���� Job Address: �S-1 V�; j �.,�,��_
Legal Description Lot: Block: Filing: Subdivision:
Owners Name:v�,( R e_�;,r.t-s Address: Phone:
Architect/Designer:���y v Address: Phone:
Engineer: �G^���� N���
Address: Phone:
REASON FOR REVISIONS: � �� �.,.,�,�� �ssC�-.�,(y �,� ��,,,;��,
Work Class: New�( Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( } �
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No( )
FOR OFFICE USE ONLY
Other Fees: � Occupancy Group: Accepted By:
Type of Construction: Date Received: ! �
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
��`,.
� u ���
i�@'�''1�'"1T.�'��
ani�p�p a9iai�19iPR11�9J�1 ,ylll�94 i}en�{i�it ii�i�g��������������������o ea��,��e����.
6 A N yi i Iliry �q �
����,�i �� � AI���,14�1�',�����I���V il�������p��ud�l �m,���llri���..
AGENCY
December 22, 2006
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Vail Front Door
PLAN REVIEW: B06-0018 Rev. 4
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
Colorado Inspection Agency has completed a review of the following documents:
1. Plans:
■ RFI No. A-112
These documents were reviewed only for their conformance to the provisions of the 2003
International Building Code, 2003 International Mechanical Code, 2003 International
Plumbing Code, 2002 National Electrical Code, and 2003 ICC/ANSI A117.1. Colorado
Inspection Agency finds the documents submitted to be complete for construction and
ready for issuance.
Additional plan review fee of $60.00 is due for 1 hour of plan review at $60.00 an ��,
hour.
�----� -
,�
ti
Sincer �� �_
--_-�.--.
�/
John Plano
Plans Examiner
Colorado Inspection Agency
Colorado Inspection Agency p:970.328.1790
1286 Chambers Avenue f:970.328.1791
Eagle,CO 81631
Colorado Inspection Agency
Eagle Office
1.?t3E�C:..?�c,���,k?�:rs Ave;r���e �1;�I
i�c��t.�[�, �c�lc:lri�do£s3631
�y7.]� / � � ��
�F'.���i�i ,�,. ��;✓`/�S/� L/�f (
�'Ct�Jw'�;f 1\C:7�Yi£�: � n�- D�
�
,�esf..�� };",�;
v:,��=
w� . '� ��. c�' �:� � � � � � �
�:_�
F'�cFr�s �xc�r��inc>i: __(�j�����k-�.�(� .----
�iuilt�ir-ic�t�'=ric.ir�l: Matthew Royer
tw)��ice f'?n����: 970-328-1790
I'"ifL;IP1C;€ RE;f, s`».
R�z��sic�r�� r3:.�rnk��r
--��^^^^^.^^ •
/2-� �'.
�-'
{... .���..�.��.
'C��STRUCTION INC.
REQUEST FOR INFORMATION
VFD Site Work& Bldg A- Garage/Dock
HCI Job No. 26006
RFI No. A-112
TO: Neha Khera DATE OF QUESTION: 12/4/2006
42/40 Architecture REPLY NEEDED BY: 12/11/2006
DESCRIPTION: Infill Wall Type Confirmation
WORK IMPACT:Unknown 5CHEDULE IMPACT:Unknown COST IMPACT: Unknown
REQUEST:
Please confirm that UL wall type U415 System G wall is acceptable for the infill walls between the South Lodge
Tower and the Garage.
PROPOSED SOLUTION:
RFI Initiated By: HCI
Subcontractor RFI No.
Distributed: SD;HPE Signed:
Greg Perry
Project Engineer
ANSWER:
As a temporary infill wall, the UL U415, Type G wall is acceptable ed ASK A-003 for additional
information. Please call with any questions or om��E�E D BY
r,r `? 'j
:. ., t. �
COLORADO INSPECTIUN � �C� r, �����, I�
� �' "";;' � xxF� AGEf�JCY � _ � �
� �-.. :��,���.a � ,
�w �,
� ,����c���� DEC i � 2006 �
Subject to ins��ciior, ari Gcmrliance to a � I
relevant Ad�pted Euii�� ,�; ,d Miir7;cipa! Cod s.
Changes in Plan� , us� app�oved. T�WN C)'�F VAIL
Date (Z-2z-c.�. E3y
Code: 2�ra 3 Z�iL' -
Colorado Inspection Agency �
Answered y• / A chitecture Date: �Z/5/�
Signed:
543 Santa Fe Drive,Denver,Colorado 80204 Phone:(303)825-1313 Fax:(303)825-3223 Email:info@hyderinccom Website:www.hyderinc.com
Fonn f rti_07_hyder071206
1/8" TO 1/4" GAP FILLED
48" WITH FIRE RATED SEALANT.
� � ASSEMBLY SHALL BE AIR
IMPENETRABLE.
Q STRUCTURE
�
H EAD METAL CEILING RUNNER
��`r FIBER BATT, lYP.
PLAN 1" LINER BOARD
' 2�° C—H STUD C� 24" O.C.
(3) LAYERS TYPE "X" �" GWB
PREFERRED SHAFT SIDE;
IN DOUBLE SHAFT
SCENARIOS, ASSEMBLY IS EVIEIIIfED BY
CONTRACTOR'S DISCRE ION.
S I L� 1" LWER BOARD
(3) LAYERS TYPE "X" " GW
METAL J—RUNNER COLORADO lNSPECTION
AG�NCY
Q 1/8" TO 1/4" GAP FI LLED
� WITH FIRE RATED SEALANT. Q'� `'Q�D
ASSEMBLY SHALL BE AIR
��� I M P EN ETRAB LE. ��Q�� �'��
�
ET
� I�I � � II-II � �� V V � I� L � GERALD
02081
� � � � °0 � '��.�� \����
31 STC 45-49: GA WP7452 `�ffl AR��
���w�
WT—ST-3H-31.dwg
�r�i,��e«�rR�`�rd V a.11's Front Door DRAWING N0: ASK A—003
4240 ���*ncr%Dc�cloper REFERENCE: RFI A-112
Vail Resorts ISSUE: —
DevelO ment Com an�� DATE: 12/04/06
Denaer,Colorado p p SCALE: 1 1�2��=1�-0°
�Aron,Colorado DRAWN BY: NK
GP G-P Gypsum Corporation
55 GP Plaza - 19th Floor
■ • � • Atlanta, GA 30303
December 6, 2006
Superior Drywall Inc.
Attn: Mr. Ray Bumgardner
P. O. Box 881
Eagle, CO 81631
Job Reference: Vail's Front Door
Product Reference: 1"DensGlass Ultra Shaftliner
Application Issue: Shaftwall UL U415 Clarification
Dear Mr. Bumgardner,
This letter was requested to clarify the use of DensGlass Ultra Shaftliner(DGUSL)panels within
shaftwall design UL U415, System G.
G-P Gypsum manufactures DGUSL panels that may be used in similar shaftwall/stairwell systems
designs. G-P Gypsum's specific 3 hour fire resistant shaftwall assembly(WHUITS Design GP/WA 180-
Ol)has similar design intent to UL U415, System G. ITS has approved the use of C-H and I Studs within
the GP/WA 180-01 wall assembly(see attached letter). Please note that UL U415, System G is a
proprietary design by United States Gypsum Co.
DGUSL conforms to the following applicable standards:
ASTM Standard Specifications
ASTM C 442
ASTM C 1396
ASTM D 3273
* DGUSL is a 1"thick, moisture and fire resistant Type"X" gypsum core shaftliner panel.
* DGUSL panels are surfaced with glass mat facing on the face and back. When tested, as manufactured,
in accordance with ASTM D 3273,Dens Glass Ultra Shaftliner scored a 10,the highest level of
performance for mold resistance under the ASTM D 3273 method.
* DGUSL is warranted for up to six month of coverage against in-place exposure damage and five years
against manufacturing defects (see attached DGUSL Limited Warranty).
Please do not hesitate to contact G-P Gypsum's Technical Hotline(1 800 225 6119) far any additional
information.
Sincerely,
�im Sc(midt
Jim Schmidt
G-P Gypsum, Technical Services
Technical Resource Manager
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . OS/10/2007
Legal Description: `7�S��_ �j6� � Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTR.ACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE_ ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115.18 108, 815$12, 533, 311.70
Totals. . . 108, 815$27, 739, 000.00*
Fireplace Information: Restricted: Y #of Gas Appliances: 0 71 of Gas Logs: 0 #of Wood Pellet: 0
********�****************�*******�***********�********************** FEE SUMMARY *********************************�*************�************
Building------> 103,206.lo Restuarant Plan Review--> $0.0o To[al Calculated Fees---> 206,415.20
Plan Check---> 10 3,2 0 6.1 o Recreation Fee--------------> $o.o o Additional Fees-----------> $3 0 4.9�
Investigation-> $o.o o TOTAL FEES-------------> 2 0 6,415.2 o Total Permit Fee----------> 2 0 6,7 2 0.17
Will Call-----> $3.00 Paymen[s-------------------> 206,720.19
BALANCE DUE---------> ($o.02)
*************************************************************************************************************�****************************�******
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading,
Excavation and
Shoring only. Other approvals required prior to approval of full building permit.
PW approval
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions
and other
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural
changes.
Additional $0.
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
due $60.00
02/07/2007 MROYER Action: AP Approval for temp. stairs on East end of
Lodge Tower.
Additional Permit Fee: 148.48, Plan Review: 96.51. CIA % per contract Permit fee:
103 .94 and
Plan Review: 77.21. Total fee of 244 .99 must be collected prior to release of
revision.
03/Ol/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter
emailed to
Doug Thompson and Neha 03/01/2007.
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock
levelers to
improve loading dock.
Billed 1 hour � $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation
clarification comment
letter sent to Neha. 04/17/2007.
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for
excavation,
shoring and grading only. Addtional approvals required for building permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval for the
construction of a
temporary stair to provide emergency egress out of Lodge Tower South. This stair
is temporary
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is for the addition of
loading dock
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval for
clarifications to the stell decking only. No other revisions are permitted by
this approval.
03/05/2007 George Action: PA Building A. This is a partial approval for
changes in
footing elevations and the slope of the foundation.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and
excavation only.
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
ONLY
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
PAGE 2
*�:�*��*�*��:*�*��:�*****�**��x�*�*�*��x�*�*�*�*�**�*�*�:*�:*�*�*�x***��*�***��*=�*�x*�*�*�:**�*�x*�x�:*�*�:*:�*�x*�x*�x*�:�
CONDITIONS OF APPROVAL
Permit# B06-0018 as of OS-10-2007 Status: ISSUED
�x�*�x*�x*�**�x*�:*�*�:*�x*��x*�:**�x*�:*�****�x*�x�*�****�x**�x*�*��*�:*�:*x:***�:�x*�***�x�:*�*�x***�:*�:*�x*�x*:x*�*�:*�x*�x**���x**�:
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: OS/10/2007
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
07/14/2006 tk Action: AP Approved Building permit revisions dated
received �
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 for installation of
Dock Levelers.
Plan received 1-31-07, dated 1-29-07.
Item: 05550 ENGINEERING CIVILS
�*��************�*****************************�*�*****�******�**************�*****�***********��********�*********�******�*�*�*****�*********�**�
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM R:00 AM-4
PM.
'L- " L;,
f �,
SIGNA'�URE�OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
******�********+**********+*�**********+********�*******************************************
TOWN OF VAIL, COLORADO Statement
*****************************************************�x**************************************
Statement Number: R070000675 Amount: $244.97 05/10/200704:44 PM
Payment Method: Check Init: LT
Notation: Douglas
Thompson / ck 2430
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 206,720.17
This Payment: $244.97 Total ALL Pmts: 206,720.17
Balance: $0.00
+*+**�******�*********************************�***�:x*************�x�x********************:x****
ACCOITNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 BUILDING PERMIT FEES 148.46
PF 00100003112300 PLAN CHECK FEES 28•96
PF 00100003112300, PLAN CK - project GFP012 67.55
-----------------------------------------------------------------------------
_...
, - - �
� l��� ?C. �'GI ��
� � � �a�-'c�:,
��,�� �
ATIO WILL NOT BE ACCEPTED IF COMPLETE OR UNSIGNED
Building Permit#: ,�U�-oo� 4'S
, � � 9T�-479-2149{inspections)
, # �
������� k REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.�
75 S. Frontage Rd.
Vail, Colorado 81657
**�All Revision submittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
f-�dc� ��s�1-rc,.�iw. T��. d�-/a C�� Per�y (�-���-c�-c-�a�3
ATTENTION: JR,CHARLIE,GREG,CHRIS
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $ �
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ ��; (�:"]�. �`�
For Parcel# Contact Ea le Count Assessors Office af 970-328-8640 or visit www.ea le-count .com
Parcel#
.. ,__..___.
��O 10`�Z2.ro 3-'�
Job Name: , , Job Address: r� U�„'� ����
v�.� I s ��-t '�vo c-
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: U�.;� �es�� Address: Phone:
Architect/Designer: ��/y� Address: Phone:
Engineer: �o��L �, ��,�� Address: Phone:
REASON FOR REVISIONS: �e,,,��, ���� -E-o p,a,,;�e e�c-�ss -Fvc .���,,'[l, l-.�t�... To�,��r-
Work Class: NewQ� Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes O No O Does a Fire Sprinkler System Exist: Yes O No )
c, r � �2.rvu-1%�,= t� t U 3.`"�`-� P��'v� rP��,�..�U � "1-7.�--)
V�l_ �c-a,wvu. �t��,y- FOR OFFICE USE ONLY DEC 18 20Q6
��`" � ._
Oth ' ee `����`�— f�� Occu anc Grou : ;Accepted By:' _ `f
Type of Cons ruc . Date Received: ,,
.
�.�� � , . �: . ,� .. ._._ ..:
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
AGENCY
February 7, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: INTERNAL REF#: 2656
PROJECT: Vail Front Door
PLAN REVIEW: B06-0018
ADDRESS: 151 Vail Lane
REVISION : Rev. 3
Dear Mr. Davis:
Colorado Inspection Agency has completed a review of the following documents:
1. Plans:
■ Temporary Stair Plan
These documents were reviewed only for their conformance to the provisions of the 2003
International Building Code, 2003 International Mechanical Code, 2003 International
Plumbing Code, 2002 National Electrical Code, and 2003 ICC/ANSI A117.1. Colorado
Inspection Agency finds the documents submitted to be complete for construction and
ready for issuance.
Additional Town of Vail fees of$244.97 (building permit $148.48, plan review $96.51)
are due for increased valuation of$40,676.00.
Sincerely,
�o � u� . s`� �� � r� .�3 �
Matt Royer � � � � `�3�� �� � �� •Z �
Building Official
Colorado Inspection Agency
matt.royer@coinspect.com
Colorado Inspection Agency p:970.328.1790
1286 Chambers Avenue f:970328.1791
Eagle,CO 81631
�PP�v�� � T�wt,�R�i- �!
0
�
0
,� 4'-I
G
� �j I
(%i"x I y Gq. ---- _ �
_ CR�P S712e�T � tl
___.<. Pl,F1�+�J i�S�
' �4 r' —
D ES iG N f'1.�
(oo�os{Lt�lE �0 1'
;_ Lr,,4,rj � o
'.�°"„� .� � -
G3x3xy$
Y.812AC,C ,A� �� 4'-I
- �lcN E-�vD
or srAi�s, -q�-�
g7�N n�.cl.���. 8188'-01/2'
':F}Ia�OfLacLS t?eqvtR�.D
_ __'.aN� Eri7�NSio7us �R-
I l��
12 Rat 616"=6'-I !16"
; �.TvAc2f�S ��Z,
�FCicV'C. /�05//.f�
; ANp Uar�D�N6� 818!'-I I/16"
�
_ � � _
� -
�
H Ss�x�x% — �
�'o Lctt�srn/ �vJ/ ��4`r
BA SE �aLA-7L `�
i 3/�„x �I"X O'–I I �^
__
,� �
==-°=-t\x6(4��X,�, �ot�iS N
����1d.�
..��R Oo���` 8169'-6"a .x__
f , :� �� f_- 4
. -
i-L i'-�,"
, (,e� ;i� °ry � -- .
� � ��.e`��tii .. ��r. .h�� � ............ _...__. . . ....i.
�
i '"`�r ro ti L '�
�� � ._ {",F,
'������f�-'�,�j��� '
�. �PP�mv�°�- Ex.���cs w�rw rc� .
�"` +ew�v�
Sub�ect to inspectipn_and Com_pl ance to ai!
relevat�t Adopted Building and, Mu icipal Codes.
Changes in Plans MUST be-a proved.
I Treads at I I"G��sX 33-9 '� Date et ZaO�gy
' t .� � �� ' ZOO 3 I�C_
;�� ' �0 Colora�o Insp�c±ion Ane y
A
ti - �usT�NG SowrN
Lo DG E 'l3�.•t E-+Q ; __ �
8u��.���G
, _____ �
�
t`�LA-tJ O
� �
crsx 3�.� � ; �
24 Treads at I I'= I 7'-5" �A � �
___ 5' �
I Treads at I I"= I 0'-I"--�-5'-0"---�{ � c
_ - c
� - ; _ � :D
.,�. �P'F�.Ip+L IN�P�crn� 1���R� _ . ►--•
Fa R- c,�EC.���,
��3���"��� HSs�1x X�� __
G`�7 ,� `� GoLc./l�'/N _ a m � m m
'�C� _ _ m � c � C^
m Z "1
� m � Q
9 Treads at I I'= 17'-5' { � �
� (� �i�_ ; ,�� � -, �
D _� ,�, �
c�s F«rr�, ; �
�3'.i' �P�`� _ F ., � �� � b
.� �N ��� � � ��� i
�' `�V f1�� Z � Gl
Go�tC I�E'�L' FTC�, ��` � �
3'-o''x 3'-o"xf!�4 TOWIV C�� �td� L ��
� w�-rk C4)�.�x a-9" o►
L3x3x%� xo-�''
�2 EAGN �P!�� BvT. ktt� U'} 3�¢"C� y�6� __.. o v o �
E.�cP. �ff oLi": � � T N
�<. -..x_ ....-F ..� x �.�. :.- .. . m m
�iti�s:E -:
�.l,E�l A��.1—�4-�A�� - � ��i- > :. , � �
� N �
����� �
��;� _ ' ���� .��- �
� .a . �
.. �,
:. . � x . . � �a � (U (V
......... . _ .. _........... ..._._. . .__....� .____... . . +..
„�,, ,._ __ _'1
� � ��..... �__ _ 4 �`
� �
__ , ,
,.. .. d
`.1 J
d``
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : REVISION
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . : OS/23/2007
Legal Description: Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER �
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311. 70
Totals . . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
�********+****t*r+�r*�***����******�*�*****t*v**�*r****�:�*�***�*a�+� FEE S UMMARY �*�**�*v**�*r+*►*+**********�******«**►�************�+*r+s*s
Building------> 103,206.10 Restuarant Plan Review--> $0.00 Total Calculated Fees---> 206,415.20
Plan Check---> l0 3,2 06.10 Recreation Fee--------------> $0.0 o Additional Fees-----------> $3 64.97
Investigation-> $o.o o TOTAL FEES-------------> z o 6,415.2 0 Total Permit Fee----------> z o 5,�e o.1�
W ill Call-----> $3.o o Payments-------------------> z o 5,�8 0.1�
BALANCE DUE---------> $0.o 0
*****t**s*******�****e*�*t***+*t*��***�***.****:*****�*++s*******►*t***st��*�*�+**s*******�+*+*�:**+*s*.***x**�*+*+**�:.+*sa*.**�***e*****+*�**.�*.
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit .
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ONJ
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 .48, Plan Review: 96 . 51. CIA o per contract Permit tee:
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/Ol/2007 MROYER Action: DN Revision 5- Dock levelers . Comment letter E
Doug Thompson and Neha 03/O1/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levela
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor ex�
shoring and grading only. Addtional approvals required for building permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the constru�
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi:
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rE
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot DocJ
Plan received 1-31-07, dated 1-29-07 .
Item: 05550 ENGINEERING CIVILS
�..**.*.**.*.*.*.*�.*...**...******.:*.*:**..*.:****..*.*►*.**+•**•**�***.*.****+�**.*.*.****■*****.*****�*.�.�**�**►*..***..*..*...*.*.*.*.*:*.:
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS[N ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
.'
SIGN T RE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of OS-23-2007 Status: REVISION
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: OS/23/2007
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
******************************************************************�*************************
Statement Number: R070000776 Amount: $60.00 05/23/200702 :19 PM
Payment Method: Check Init: LC
Notation: #1126/GREG V.
PERRY
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 206,780. 17
This Payment: $60.00 Total ALL Pmts: 206,780. 17
Balance: $0.00
******************************************+*************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 60.00
-----------------------------------------------------------------------------
AGENCY
Municipal Building Department Services
4/13/2007
Charlie Davis
Chief Building Official
75 S. Frontage Road, Vail
RE: PROJECT: Front Door Building A
Rev. #5
INTERNAL REF #: 2971
PLAN REVIEW: # 606-0018
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
Colorado Inspection Agency has completed a review of the following documents:
Plans: ASI A-017
Fees
10 $ 80 $
11 $ 81 $60.00
Total Permit Fee $ Plan Review Fee $
Hourl at$60 1 $60.00 Increase Valuation $
These documents were reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. Colorado Inspection Agency
finds the documents submitted to be complete for construction and ready for issuance of
the revisions. Please see attached conditions of approval.
Sincerely,
Matt Royer
Building Official
Colorado Inspection Agency
(970)328-1790
Matt.royer@coinspect.com
Centennial Office: 12503 E.Euclid Drive,Suite 210•Centennial,CO 80111•(303)734-4567•Fax(303)708-1790
Firestone Office: 11409 Business Park Circle,Suite 350•Firestone,CO 80504•(303)774-1388•F�(303)774-0455
Windsor Office: 561 E.Garden Drive,Unit B•Windsor,CO 80550•(970)686-7511 • 1-800-400-1581 •Faac(970)686-9248
Eagle Office: 1286 Chambers Avenue,Suite 101 •Mailing Address:P.O.Box 1618•Eagle,CO 81631-1618•(970)328-1790•Fa�c(970)328-1791
Colorado Inspection Agency
Eagle Office
;`?s;fi C}�c.�rnk>e:rs AvE.,,,u�> �1;)1
FC:iC.7€E'., Cl`?IL)(�C7C.�G�Pi�6:.{E
F'��rr��;i�l� �:
f'rt�j�c:fi I�:c7rr�e;
C`.��s�.��iptic�r�:
�i��—' ��?` Q
�'t h� -p�
f"'
�� � �.
y�; �� f
S� �i;. x.� . _,� . <. _�... , � ,x", ,_ ...
Pl«r�� �x<:rrnir�c;r: �b�� ���'�U
F3viidir�ca �)ffic.ic�l: Matthew Royer
v)ffir_� �'f�c,�-�e: 970-328-1790
ir,t�::rr�r�l Re;�. �_
�euisi{Jr;r�������k�er
i I�i�i���iV'`-� �Ci�,� � 1
� ���� 1
�� ��� �
�xi�t�t�=t�.,:,�:c:;�,;a�u;�; C„7yc;
, (�•- �S► � `1 `-'
� � � .
APPLIC ION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
� ��� ���� (zt:.uc,� Building Permit#: �j6 -`c�1 g
�, ��� '' �.� S jti��7 97Q�479-2149(InS�ections)
_- �?V, �
��'���� � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mert�au'ual,.��_.�
75 S. Frontage Rd. ��� ��, (C�,`-, ��' ;j �`� �; ,�
Vail, Colorado 81657 � �
***All Revision submittals must include the Field Set of approved plans. furth ins ections� '�
will be preformed until the revisions are approved. � ��f�
0
CONTRACTOR INFORMATION -.
�
General Contractor: Town of Vail Reg. No.: Contact and Phon . '
�'i Zl' �onS I�.c b� �f� � pet� �9'�O) H�-G-2 t�l 3
ATTENTION: JR,CHARLIE,GREG,CHRIS
Contractor Signature•-
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea /e Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel#
M �. .. .,, � I v I o � 2z !o �-�
Job Name: v �` r r } �o�. Job Address: l 5 1 Vo..l ��¢
�,,, 5 (an
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: G Address: Phone:
V � � OZ.vso r1�S
ArchitecUDesigner: Address: Phone:
t'l�/`'(O
Engineer: , , Address: Phone:
�}`� L� �..e �
REASON FOR REVI ONS: ��� �v�l; / ^ t e
: /�lJ-��-� � /'n"�p�J G. �-0 G�U�/1� �d Ut \
r
Work Class: Nev�� Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/Type of Fireplaces Existing� Gas Appliances ( ) Gas Loqs ( ) Wood/Pellet( ) Wood Burninq ( )
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
FOR OFFICE USE ONLY
Other Fees: Occu anc Grau��. � Accepted By:'
Type of Construc#ion: „Date Received: ;
,
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
` io.
AGENCY
COLORADO INSPECTION AGENCY PLAN REVIEW COMMENTS
TO: Contractor Architect Enaineer
Hyder Construction 42/40 Monroe & Newell Eng
Doug Thompson Randy Hart
EMAIL: dthomson(a�hvderinc.com rhart(a�4240arch.com
FAX#:
Revision Number 5
NUMBER OF PAGES: 2
FROM: Matthew Royer
DATE: 03/01/2007
BUILDING PERMIT#: B06-0018
OWNERS NAME: Vail Resorts Co.
SITE ADDRESS: Building A and Site
SUBDIVISION: Mill Creek
OCCUPANCY GROUP: S-2
TYPE OF CONSTRUCTION: I-A
NUMBER OF STORIES: 3
The design documents submitted for this project have been reviewed for complianceanrith the locally
adopted codes and amendments. The following comments must be addressed before a building
permit is issued.
For processing:
. Please submit (51 complete sets of revised construction documents containinq the requested
information or plan revisions with all revisions clouded or otherwise identified.
. Please respond in writinq to each comment bv markinq the attached list or creatinq a
response letter. Indicate which plan sheet, detail, specification, or calculation shows the
repuested information. Please send revisions to the attention of the plans examiner with the
buildinq permit application number noted.
Responses such as "will comply with code" are not adequate. Revised drawings must
clearly show code compliance.
A RESPONSE LETTER MUST BE INCLUDED WITH THE REVISED PLAN SUBMITTAL.
. Please be sure to include on the resubmittal the enqineer's or architect's "wet" stamp, siqnature,
reaistration number and date on the cover page of anv structural calculations, all structural details
and structural sheets of the plans. For commercial or multi-familv proiects all sheets of the plans
must be stamped.
V:�Plan Review\Vail�Front Door\tov-b06-0018.rev5.DOC Page 1 of 2
BUILDING DEPARTMENT COMMENTS:
1. Sheet ASK-A-005; Provide referenced detail 1/A501. Sheet A501 is not part of the Town of Vail
approved and issued plan.
Please refer to the cover sheet for information and instructions for resubmitting plans. The recheck of plans
usually occurs within 3-5 working days of plan re-submittal. In order to avoid delays please check all requested
information is included with the resubmitted plans.
Contact Person:
Matthew Royer
Building Official
Colorado Inspection Agency
970-328-1790
m att.rover(a�coi n s pect.com
� t l
��,�� iC..2�e.G\ v—►ti.
�'� . I
��..v c�-'�. r�-i\
�
�...,,.._ _.,..._._�,
V:�Plan Review\Vail�Front Door\tov-b06-0018.rev5.DOC Page 2 of 2
� "
4240 � �
ARCHITECT'S SUPPLEMENTAL VAIL'SFRONTDOOR
INSTRUCTION No. A-oi7
ro: DougThompson/ Hyder Construction, If1C. PROfECTNO: 20693.OH
543 Santa Fe Drive issueo: 01.29.07
Denver, CO 80204 FROM: genjamin Gray
303-825-1313 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructions
indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time.
Architect's Supplemental Instruction Title: Bldg A—Dock Leveler Addition
Reason for Change:
At the request of VRDC,two dock levelers have add to the loading dock. �� II�
6
_
escription of Instructions: z r � • �-��-�'� � � �� �
See attachments for clarification. !
� , ,�
. �'i �i
� �� �, � �;--1 � � , 2.��� �
��� �;��,� ���-�,', s���,���
ro � �
;� ._ ..
��� ' _����;��`'� � _
Attachments and Enclosures:
4240 ASK A-005,dated 01.29.07.
ABS ESK A-006,A-007, and A-008 dated 01.30.07.
.. Copy To: ASI File
BY� Rick Caudel/VRDC
Jay Watson/ABS
Received
42�40 ARCHITECTURE INC
1621 Eighteenth Streec
Suite 200
Denver,Colorado 80202 The information contained in this message is privileged and confidential intended only for the use of the individual(s)or entity(ies)named
t 303.292.3388 f 303.292.31 13 above. If the reader of this message is not the intended recipient,you are hereby notified that any dissemination,distribution,or copying of
www.4240architecture.com this communication is strictly prohibited. If you have received this communicaGon in error,please notify 42/40 Architecture,Inc.immediately.
�`�IDIN� � r"`���� � � — �
i
_�_ ��
� � D(
DOCK LIGHTS �
` RE: 10/A501� � ��
8152'—10••
JG FOR EX.
INTAKE
3/A401
53'-3/ "
/ ,
�
3
TRENCH DRAIN/
RE: I�ECH. /
�03
LIGHTS
8153'—0"
LOADING
DOCK
A116
�
i
�
�
FIN. LOOR
815 -0
a
^;
/c� o
Q �
o\ °��
I.C.0 BAR RAILER��
RESTRAIN G DEVICE ^
TYP. AT CH
LOADIN SPACE. , �
%
� Ai.,.
�0"
�
IJ
�
.�...,.,
�3'
iy2'—io.,
� � ,l+
��� _
I
���♦
�•�•���'�i
-'�'•=--
��OG/� 6, �„ 4
�
��I P2.�D� ABV. �
\ 1
��`
DOCK
PLATFORM ., /.
A106 � ���
�s
81 "
DOCK LEVEL�R�
TYP. OF 4 \
� F C4/
DOCK LIGHT � �
\
�'r,.
o .�• c, .
� � �
�
�
_ � \
� '
� � DOCK
� � �. a �nP�
� , � o
v�- ^\��•
3�• � �
/
�0 8152'-10••
DOCK HT \
�RE: 1 A50
� "�QP�v� �.
``^� l ��'' ��v`�i jy
` /• / .
1 5� �
CORRIDOR/�
A111
CHILLER
A111
RE: BLDG-B
M103 FOR EQUIP.
� '
�B
�O �
� � � �
� �_ �
BEVERAGE f�° L
COOLER `
0
i�
6'
�
� >
FEC3/_ � �
�r.
�. �
, � � ��
A107 �
.<
� � . .
�� ` /
� �,
�� i
� � � .,
� .
� 4 V � FORM CONC. TO ALLOW FOR AS v � � �� � '• �
EXHAUST TUNN UNDER DOCK AND � - `
� � RAMP— RE: M1 1 AND S101. 1�; �, / / ••` �
\ \ � � � \ 5 fq � (4896 SQ. IN REQD) � � " �-ti FL001
� 1 / OPEN
\ \ \ 6.
� fQ MECH
\ � � \ � / / � 6���
\ (RE:
� �.�• Q� �(
�
O
O
� �no
I oo.�
i��
� oa�c�
Q� a�o�m
b����
Z � �
3
0
�
�
� �,
Q �
n.
� � o V �
� �, o
OA� � �
�
�
0
�1 0 � oa
� Q
C�
�
` � , / REV� —_"' FQ � / ,� ; . `' ,�� ° �o .� Q �
� 7 ��.� a o
� � � ApR � � 2007 � / � , o �
� � � LINE OF � ' � c
� � $ BUILDING / ..� A D � Q
` \ �COIARADO INSPE T14� D ABOVE �' � ' �
\ � AGENCY '' � 02 81
� ' - 9 / � � \ \� ���
� �
�, 4n WIDE / � ,;� A ���
si=,> z'_z" . � � � . . PAINTF� I INF / � _
� �� PARKING GARAGE/LOADING DOCK—PARTIAL LOWER LEVEL FLOOR PLAN
1 SCALE:1/8"=1'
�
� N
� ^
O �
��
C �"r
� �v
1�
�� �� �
!p'r�`0
A�
� � C '
�
�
0
�
� �
���� . 0
� �
�� �+ �
�v I
� �
� �
0
�
����v��tltltl►tNil�
t,��\^ e e... ,,
D \� ��� :
���:� O �0�s�'Y9/s
�O i
�p, a� w
Z'• �'`--`'�
Oa� ��,z �,�
iS�r" , C"�r rr,_
c:i r^:� e� `';,,,�\�
� A� e `�}_' 6 �,,``_
� {"i/��• [�
�1'/�V j�o, ! 1�a 1�,,A.,,`,,
/� �[��4�a e �' 'v�`},�:.-
/�/� G ��i\�`,�.
�������lIII!{ i\e�`,
EG�IIIPNENT
KEY
A�I
lele-e-i
�KIR.�t-�
SP-IA
SP-2
5E-I
TG
I
TF-A-I
��I
DL3
DL-4
HIR
R1MP PAI�L�__...
NOT U5�
EtEYATOR
SUhP PIX4P
5B^IP6E E.ELTOR
PUMP PA18
TRASFILOMPAGTOR
6ARAFiE�
FAN
QEVATOR MAGHIP€
FAN
LEVELB2
l.E1/F1.�
LOAD
PXMI,FL
10 HP
3/4 FP
�/4 NP..
�,4�
(�2HP
10 HP
2 HP
in r+�
5 HP
5 t�
��
��
��
�
�
�
�
�
�
�
0
Y
�
�
�
�
�
�
BRANGH GKT.
GONDUGTORS
3�N0,1�106.
2�noJ•ioB.
�tinnxin,c
2�12Jx126
3�12,IR126.
3�IOJsl06.
3�q21�126.
2�12,1�126.
3�N2JM26.
3KI2,1�126.
C.OND.
3/4'
in•
I/�•
in•
3/4'
3/4'
in•
in•
�n•
I/2'
DISGONNEGT
SWITGH R15E
30A/2P 90A
FRN
30A/2P 30A
FRN
R/fAl7P �AA
__.._, � �
6T0
30A/'�P
BOAl3P
�o,n�
!TO
90PJ3P
30N3P
ISA
FRS
30A
FlZ5
IOA
FRS
15A
F'it5
ISA
FRS
PAA�LBOARD
�
LB
IA
5�PL AN5
N2 GIRGUITIN6
5FI
MH
e�
�
MH
F�
I.PRWIDE WIRIN6 FROM THE 5Uh�R1MP GONTROL PAPEL TO EPCkI PIR�T'. PROVIDE 3MIOJ�106.,3/4'G
2.5�SPEGIFIGATION I61�0 FOR VOLTA6E DROP TABLES. INGRE./U�E WIRE SIZE AS REGMIRI�FOR VOLTA6E DROP.
3.MJLTIPLE PIfiGES OF EQUIPEhBti ARE GOPB�GGTH�TO THE SAhg BRANGH GIRGUIT. PROVIDE A R1r.�ED DISGOMEGT FOR EP6H PIEGE OF Ep11PN�ti.
4.Ki11Ph�NT GIRGUI'f�TO 501JIH TOI�ER LODGE BUILDIN6 ELEG7RIGAL SERVIGE.Sff SOUTH TOYER LODf�E BUILDIN6 ELEGTRIGAL DRf�Y�IN65 FOR
r�ir�oRr�nnort
REV��i�IED BY
AFR 1 2 2�::�.?�'
COLORADO INSFECTiON
AGENCY
.�
�
�
� N
� �
O �
7�
N•
� ��
A �v
a
•+
�� �� �
tp�'a\0
A�
� � �
b
� �
0
�
G
�
� �
�� 2
.��. .[�'.!!� . O
���� �
s� i
a
� I
O
�
SG�lEDULE
PAt�L NO: MH 30-Jrn-0l
LOGATION: MAIN ELEGTRIGAL ROOM VOLTA6E L-L� 480
PROJEGT� VAIL FRONT DOOR VOLTA6E L-6: 2l7
.IOB NO.� 2001-134-03 TYPE� 3PH/4W+6
GOMMENTS� DISTRIBUTION PA�LBOARD
BUS RATIN6: 125A S.G.RMS RATIN6: 42p00 AIG
MAIN O.G.DEVIGE� MLO
MOUN'fIN6: SURF�4GE
GIR DEVIGE CANNEGTED DEMAND LOAD PH LOAD DEMAND GOM�GTED DEVIGE GIR
NO. AMPS POLE VA FAGTOR SERVED � SERVED FAGTOR VA POLE AMPS NO.
I 20 3 2106 IAO DL-I ��A 9A�-A-I I.00 3300 I 20 2
3 — — 2106 I AO ---- H H1FI-A-2 I.00 3300 I 20 4
5 — — 2106 IAO -- G 91H-A-3 �.00 3300 I 20 6
'1 20 3 2106 I.00 DL-2 A EUIi-A-2 I.00 3300 I 20 8
q — — 2106 IAO ----- B 61H-A-4 I.00 3300 I 20 10
�� — — 2�pb IAO ---- G �JH-A-S I.00 3300 I 20 12
13 30 3 3bb0 IAO TRASH GOMPAGTOR A BJIi-A-b I.00 3300 I 20 14
IS — — 3880 I.00 — ^ B SPARE I 20 16
�i — — ____ AS-A-OI"1c sP,� i 2o ie
Iq 20 3 2106 IAO DL3 A SPARE I 20 20
21 — — 2106 IAO ----- B SPARE I 20 22
23 — — 2106 I AO — G SPARE I 20 24
25 20 3 2106 IAO DL-4 A PANEL ML TRAN�ORMER I.00 2864 3 50 26
71 — 2106 I AO — B — I.00 1315 — — 28
2q — — 2106 IAO — G — I.00 1664 — — 30
31 A BUS�'.�ED SPAGE 32
33 Bl�SPAGE B BUS�.�ED SPAGE 34
35 BI�SPAGE G &155ED SPPGE �
37 BU55ED SPAGE A BU55�SPAGE 38
3q HU55ED SPAGE S BUS�'�ED SPAGE 'b
41 HU55ED SPAGE G BUS�''.�ED SPAGE 42
GON�GTED LOAD�
PH A VA= 25pb8
PH B VA= 20,21Q
PH G VA= 20,568
TOTAL VA= 65,855
..��NMtlitllili�a_
� ,•�`�'��o
�`�� '��•
.
w `��a
o 'O•
r�.
tV -��-'
o =r"S
�-��-
a �;
s
0
�9ri�J �
�-o� 1(\��-`y':
�Jl� `•o� ,r•^„�`� �.��
�' R � �ti
/�!`���t o�! ��io����l�l�.
DEMAAA!!D LOAD:
PH A VA= 25A68
PI+B VA= 20,219
PH G VA= 20�68
TOTAL VA= 65,855
TOTAL AMPS= 19.21
REI/����� �Y
f�,��( � � ��`;:i r
COLORADO !NSPECTlQN
.— AGEr,i,^y
-�r �'� ' •�
,, �,. / G�P�!ERA--OK ���.
-r-r—r', � 1�'�':�' , /�';i` 13,� ����
^—T�-r�'�_�--}1����-� - n '� X3 ���`�. �a�
:��i ?_``�� � � '';�� ;, K ``��/i
,: ,
� L4E_6 �— — �-- -^, K ��,,\ i ��/
—_ � � G ;�I K �/O `�
--_..��-''"`_ ' \\ -�LE-18 i��
17 � ,�
� ,
G 5LE-3,,� �,�� ; '�`
�`'
---aZ - - —-- - - � - -
\��
� �� _�__ � ;i _ -�„ ,_ , � _�`
��
S A-01�7 D XI ' i� �� � L4F�� � Q'�.,�� �
�� a.. - � 17 17 � � ( J ELE-18 13 s-%
�\ �SLE-3 \
,�- � ' " �,�� L4�-5 �
� �
,- �,.�
/ � ��G 2A `� ';� - Q �.� ��L�-3,��
� � �� ,
�'� - I�i ��E-18
� i J , �._ ,%' �� �� ELE-18,-_-' A ;
;"
\
'4E- 'r ' L4�=�t3�\ �'�--� G \ ���; �'
;
/�' \ '�,_ ` ' \\ � 17 \ ��� // G /
�` ' - '� ELE-18 �I�
� � + � u�.``,GK i
)ADIf�G �4E-2 ;•� � .......�����\ PLA,l1F0�N
;
�OCK �,�� i�, \ `'� ,4106 \` ' %,
� � % � �?��\�\ � XI� ,�
A' 1 6 � � I-�
,' � �I �\\ \y �
% � ,..� , K
/ ....y_ , �
/� R-A �
�(- , •p O \ ,
, , �/
/ / �L � I� 5LE�
� , '�
/ 2 \ 3A \
% �L-II \ /
! ` ' i�, ; DL \
�' � � � �1 � ��4�-I L4E-II �� G� ,
� % � 17
� % ;;` ���,..
� ' 4E-I � � L4E
l'I / � l
� -G , ,
� � ; 20 ' � �
�OUTE I N � / , �
AWINC� j%� �' /�
/�'I, -A` I�
�
� � f� � O L
3
� y,��;'�.t a��i h�;�:°,;,, r �,� ��� '�' DL
Vv / ,
� ' � C5 ;tr_ ^, ��'r� , ���'t:. � �
q,Q o� c �'�`i. % II
/ �� dr � `. / _ ��
♦ ♦ •p `. r �",���a
/� / ; o e o , -
4 , , v � � �
0 � % _ °� ; °Y '` ��'R 1 � i
, ��_.� �
QJ � ;' _ m� '"`�" �'; � - /
) � !� = m e _ ,
� ; m�R
� ��y' � '�,�"� COLORAGO IP!�PE ��
5LE-q Q 20 ' �F�°°�.. ..•••"0���\� AGENCY / / �
i
�//������ nAiin�e`�\\\\ � ' '� � �'�/
� �° 3 2007 � ' ' �
; � ;
� " �°°" ail's Front Doo �►�� �:ESK-A-ooe
4240 � , n..� �: E,o,�,
vail Resorts �: �-�w,»oac-�
Development Compan.y � ���
n.a..e. c7o�or.ao �.m. coloraao oRIWrN str: Yfn►
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 09/20/2007
Legal Description: "��-�,5 04 oUz� Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
AFPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 . 70
Totals . . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
*�++********x**�*r►*t**t**************xr�s*�****s***�r****►�t******* FEE S UMMARY *******�****�+**�►***t*+**�*******+���**►*�**********►*s�*►*
Building------> 103,206.lo Restuarant Plan Review--> $0.oo Total Calculated Fees---> 206,415.20
Plan Check---> 10 3,2 0 6.l 0 Recreation Fee--------------> $o.o o Additional Fees-----------> $6 64.9�
Investigation-> $o.o o TOTAL FEES-------------> 2 0 6,a 15.2 o Total Permit Fee----------> 2 0�,o s o.1�
W ill Call-----> $3.0 0 Payments-------------------> 2 0 7,0 8 0.17
BALANCE DUE---------> $0.o 0
******+.*.*.*************«�s*s�*.r****t*t*�s�****..�:a**r************�+**+*�***s*s*****r****:******�+******►�►�s.***.**■+.+**�*��*s*++***+*s*s*+*•
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval oY tull building permit.
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 .48, Plan Review: 96 . 51 . CIA % per contract Permit tee:
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/O1/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter �
Doug Thompson and Neha 03/O1/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelE
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No aaaea
Additional plan review fee of $60 . 00 due
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor ex�
shoring and grading only. Addtional approvals required for building permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the construc
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi;
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rf
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot DocJ
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
s+....+..:*:+:+.�.s..*s*��**.**.*.s..*.:*.*.:*.+�.+*+**s*s*..:.*..:+.,*.*+*.*.�.*.***.*.�.*.*..*.**...***■�*****.*.«•*.:.:.:�*...*.**■.**.*s*..*.
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOUR5- VANCE BY TELEP 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
�
SIGNATURE OF O OR CO HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 09-20-2007 Status: ISSUED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 09/20/2007
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
****************+*************+*+***********************+*******+*******+*******************
TOWN OF VAIL, COLORADO Statement
********************+**********************�********************************************+***
Statement Number: R070001926 Amount: $300.00 09/20/200703 :25 PM
Payment Method: Check Init: LC
Notation: #56718/HYDER
CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207, 080.17
This Payment: $300. 00 Total ALL Pmts: 207, 080.17
Balance: $0.00
+*************************+***********************+*+******+++****+*+***********************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 300.00
-----------------------------------------------------------------------------
/� Cc �
,�`1► I� C bu � It inc.
coLt���ao
si27i2oo7
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Modify existing grade to improve drainage/accessibility
PERMIT NUMBER: B06-0018 rev#11
ADDRESS: 151 Vail Lane
INTERNAL REF#: 4225
Dear Mr. Davis:
SAFEbuilt, Colorado has completed a review of the following documents:
1. Plans:
■ 65 Civil Sheets, Review responses
Fees: 5 hours of plan review at$60.00 an hour. $300.00
These documents were reviewed only for their conformance to the provisions of the 2003
International Building Code. SAFEbuilt, Colorado finds the documents submitted to be
complete for construction and ready for issuance.
Sincerely, , � ' - _
,,� ��x�
Matthew Royer�
Building Official
SAFEbuilt, Colorado
P.O. Box 1618
Eagle, CO 81631-1618
(970)328-1790
(877)428-6412
matt.rover(c�safebuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓
. REv, 11
����
APPLICATION WILL NOT BE ACCEPTED IF COMPLETE OR UNSIGNED
Building Permit#: ����o j k
, • �� l 970-479-2149{Irispections)
�
� .
�������' � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision �ubmittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
! 1 C.Q P� l�O n �f-:�.c� 'on �UGj- �-'� - 21'r' -
ATTENTION: , JR,CHARLIE,GREG,CHRIS
Contractor Signature: j'
�
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ELECTRICAL: $ � OTHER: $ �
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel#
_ __ �IOI�S�.2ro3�
Job Name: � , Job Address:�� U�;, L�
�c� ��� ��u.-l- I�vv r- c V�.; i ����s
Legal Description Lot: Block: Filing: Subdivision:
Owners Name:U4i1 (Ze s�J'+� Address: Phone:
Architect/Designer: ���� Address: Phone:
Engineer: ���^c Address: Phone:
REASnN FOR REVISIONS: �i�;��;t��� clrz..�;�;�� 1� ;MN��.,L c�,�;,,��� -�> �, `���.�,'r,ty
Work Class: New� Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior� Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes( ) No( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
FOR OFFICE USE ONLY ��"�`
Other Fees:' Occupancy Group: � Acce ted B :
Type of Construction: �D-ate Received: '; �
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
Alpine Engineering, �c. ALPI N E
34510 Unit A-9, Edwards Business Center =_ -
P.O. Box 97, Edwards, CO 81632 — =
PH: (970) 926-3373 FAX: (970) 926-3390 ENGINEERING wc
LETTER OF TRANSMITTAL:
To: �w,�! o f [/�i�, Date: /�,� � �o0 7
{
Ac�r•e�•�c /7�Pa�vr+z..5�- _ Job NO: ��l2S9. /
Job Title: VA�c's Fil..•r "�t oo•e
CO. T�d �DKNH.J/TY _�EvttoPA4s�r
We are sending the following items via �eci ue,�.Y
shop drawings reproductions ngina specifications
copy of letter change order samples other
COPIES DESCRIPTION DATE
3 UA>L-�S F2b.aT 1J�Q�Z. ' �L� ��-f%tf�T ��+iT Sk6h•'�7Y�G S/8
��.�� c��ZL Sr.a..�,o� � �,�..�eo C.�•�. �.Q..�we�c S
Z I�f � t`��n��r �z S�Zt, !�e2 fK�uc �02te ��. ���
� u/3c.ic L.�O/Lcs 2,sf'o.�,S� ��F"��. �c5 $6
�7i A-crr %c..unJ irc S�aw�S cS�`cT�o�
These are transmitted:
far approval as requested reviewed for your use
for review and comment for your record after loan to use other
Remarks: /�a,�.�„i,G, �.f�i,•,�s /�[�5!'a,�S� F�4o4., �u/3uc t,�o2/cr /`eJ/�J
Copies to:
Signed:
, �
�
. f
�1►!Y V1 I111L =
Department of Public Works & Transportation
1309 Elkhorn Drive
Vail, CO 81657
970-479-2158
Fax: 970-479-2166
www.vailgov.com
MEMO
To: Rick Caudel, VRDC, Bob Herbst, Alpine Engineering
From: Tom Kassmel,Town Engineer -
Re: Vail Front Door Revisions to Final Grading Building Permit Plan Review-B06-0018
Date: 6/OS/07
CC: Charlie Davis, Matt Royer, George Ruther, Mike McGee
The Town of Vail Public Works Department has received the Final Grading revisions to Building Permit plan set
B06-0018 dated 4/27/07 for the Vail Front Door development. The following comments will be required to be
resolved prior to approval of a Building Permit. Please submit a response letter with the next submittal responding
to each comment.
RE: Vail's Front Door,Building Permit Plan Set Review Responses 07/31/07
On June 20�' we met to discuss comments of your review of the Civil Plans (B06-0018) dated Apri127th, 2007.
The following is a synopsis of the meeting and provides a response to specific concerns:
Comments
1. Provide approval signatures from utility companies regarding changes to utility configurations.
AEI has provided a review and authorization of plan coordination with Holy Cross Energy and Eagle River
Water and Sanitation. A signed letter or e-mail confirming review approval has been sent to the Town of
Vail.
2. Provide updated easement plans consistent with relocated utilities.
A revised color print set of proposed easements has been provided to Public Works as a record set. As the
project continues, documentation with need to be generated to follow anticipated easement requirements and
time frames when it will be appropriate to record associated easements.
3. Please note to coordinate with the Willows Development project, regarding the roadwa
construction on Vail Rd and Willow Rd. -----------�C (�~f
A coordination meeting occurred with the Public Works Departme t to rev�t�����sQo`� ' oad nd
Willow Road. General coordination notes have been added to the opo ra mg Plans.
��� �� ��n�
�,���built Gc�lorado
,
4. The revised entrance to the Lodge at Vail and Lodge Tower conflicts with the operation of Gore
Creek Dr. Gore Creek Dr. was designed to be half pedestrian and half vehicular, functioning
primarily as an entrance. The new layout promotes the southern quarter as two-way for the Lodge at
Vail parking garage. This also becomes an awkward entrance for guest and emergency vehicles.
Please have the entrance and exit access off of Vail Rd.
Vail Resorts Development Company(VRDC) and Alpine Engineering(AEI) coordinated options for the
Lodge at Vail Parking Lot revision/re-construction phasing with the Town of Vail Public Works Department
and will submit the North Lot as a separate project. The entrance and exit will be from Vail Road.
5. The drainage flow pattern coming out of the Lodge at Vail parking lot should be directed into the
proposed inlet, so not to flow into the roadway and across the pedestrian paving stone walk.
Appropriate inlets will be provided to collect drainage from the parking lot prior to the sidewalk area in
conjunction with proposed development plans (see comment#4 and#6).
6. Show longitudinal and cross slopes in the Lodge at Vail parking lot.
The South portion of the Parking Lot has been revised and a new plan has been provided as Sheet C 10:E�
(see comment#4 for the North portion of the Parking Lot).
7. C11.B, why has the tunnel exit been narrowed to 20'. This seems too narrow for two way traffic
confined by such tall walls.
Attached are the Landscape Plans sections of the tunnel showing the road width and adjacent clear zone
outside of the roadway beyond the face of the curb. The tunnel section is wider (24') than assumed.
8. C 11.0 &C 12.B, the proposed change to path should be oriented further west where it connects near
the tunnel exit. This path needs to promote continuity with the Gore Valley Trial which comes thru
the site adjacent to the exit tunnel. (See redline) The maximum cross slope of this path shall be 2°Io.
AEI has provided notes on the plans that the proposed path location is subject to revision with coordination
between the Town of Vail, VRDC and Mountain Operations during/following landscape installation in
2008. A path is shown south of the plaza connecting in a `T' intersection noted with a m�imum 2% cross-
slope to the Pirate Ship Park area.
9. C35.0, this sheet does not show the new layout for Lodge at Vail parking lot.
Both the interim and future grading plans are reflected as a part of this re-issue.
10. C35.0 Detail, since the construction of the village streetscape the Town of Vail has made a
modification to the heated streetscape paving stone detail. The pavers sha11 be set in a pre-
compacted 2" sandlcement(10:1) mixture with NO insulation. Please see revised detail and spec.
'The Town of Vail provided AEI with a revised specification that is included on these plans.
11. C36.0,please place legend back on this sheet showing TOV heat and VR heated areas. Along with
material type legend (asphaldpavers/concrete).
AEI has replaced the missing legend on the plan sheet.
12. C40.A, it was mentioned in a walk thru with VR that they were looking to place equipment in the
open spaces behind the columns on the south side of the L c�ing� '�iI� 3� rease b ing to
there attention the need for these areas for turning moveme ts as sH���n'��J�h�� _
It is intended to utilize all available storage space within the loadi do k area. After turning p tter s are
determined, any available space may be utilized. �u� � � ����'
AEI,07/3]/2007
SAFEbuilt G�lor�do
— • � • • � — ' • _ • — � — • —
� � : o�, �" ```���� r'
• :° � , � , : �� `
• � ��:� m o o��, - � � /
a �� . � � �
. . �.
,�., � :: � .. .�
•��'� ��,� : . � �
,� � � '� ea .� � .
���' �� 1 j� \
• .. •s ,
��� * � / `
� � \
b � Q
� ,�••,�I� ���� � • �� ♦ /
r • I � • . .
� ������ j �Q�,..
.I�� • 0 0 ��P�,�
s ' ��L �
I • • q
� � ,i
• � ° �
• �'�" •O��- •.
! •. , `.�l � ��'.� �
���v
;� ,1',,�� �
1� � m o
_� � � � ' ♦',,��
. � ���i�. 0°e
� :(:
�':
o � �° � � s
y � - . .
�� ���v�r ; o . 4 ;
'���� � � o :� `����. °�
., ��y � :. o
: , ��
. •'
� . :
, .�. �., �•� ��
; _ � �� ���. � �, i • �
.� .; � . �, . � �
� 1R � �• � 9a�
, s ' , ' ' • , �,�
��
� � ' �i ,�y
�� � —
• '.
. � • - � � .
- � a
� ,� �� i i i � � i i e � � d � � i
� � �i� e i i i
. ;i o ,
e� ► � ' � s
� �
�
� , � e
� . �'is. '. . _ _
y (� . %� J � ' � ( '
. .
CONCRETE TUNNEL WALL WITH
SLEEVE STONE VENEER
TING AS PER
JGINEER
GEOTECNNICAL
:COMMENDATIONS
BGRADE-SEE
°OR
IONS
1'-5"
CUSTOM MANUFACTURED
KEYSTONE RIDGE DESIGNS 4'-0°
ATIANTA BENCH,PRODUCT N0.
AT14,WITH BACN,FASTEN WITH(4)
MASONRY ANCHORS PER BENCH
NPE-3 CONCRETE PAVERS
2"SANDBED WITH SNOWMELT
6"COMPACTED GRAVEL BASE
EXISTING UNDISTURBED SOIL
18"WIDE x 12"DEEP
PERENNIAL PLANTING BED
CONCREfE WALL PER STRUCTURAL
ENGINEER
WASHED GRAVEL
4"SUBORAIN AS REQUIRED
CONCRETE FOOTING PER
STRUCTURAI.ENGINEER
COMPACTEDSUBGRADE•SEE
SOILS REPORT FOR
RECOMMENDATIONS
4'-0"PLANTERS(QTY.7)
4,,0.
�
1'-11 1/4"
� 3.71°
BENCH PLAN DETAIL 1-
WESTERN PLAZA(QTY.9)
SCALE 314"=1'-0"
4'-0"
�
1'-11 1/4"
� 6.81°
BENCH PLAN DETAIL 2-
EASTERN PLAZA(QTY.3)
SCALE 3/4"=t'-0"
4'-0"LONG MATTE BLACK METAL
PLANTER BOXES WITH LINER,
FASTEN TO BENCH BACKS
CUSTOM MANUfACTURED
I�YSTONE RID6E DESIGNS 4'-0"
ATLANTA BENCH,PRODUCT N0.
AT14,WITH BACK,FASTEN WITH(4)
MASONRY ANCHORS PER BENCH
3"STONE CAP TYP.
TYPE-3 CONCRETE PAVERS(BEHIND)
18"WIDE x 12"DEEP PERENNIAL
PLANTING BED(BEHIND)
570NE VENEER WALL AS REQUIRED
BY STRUCTURAL ENGINEER
TYPE-2A CONCREfE PAVERS
2"SANDBED WITH SNOWMELT
COMPACTED SUBGRADE-SEE SOILS
REPORTFORRECOMMENDATIONS
EXISTING UNDISTURBED
SOIL
1"=t'-0"
FINISH GRADE
SUBDR4IN,REFER T0
CIVIL ENGINEER'S PLANS
�
3'�&"
g
. 3��a: � � ��
�: � � �
I
�I � '/
u �
�
e.
REMOVABLE METAL SAFEN RAIL
STONEVENEER
CONCRETE RETAINWG WALL
AND FOOTING PER
S1T2UCTURAL ENGINEER
CONCRETE PAVERSTYPE3
2"SAND SETTING BED
COLORED CONCRETE CURB,
REFER TO CIVIL EN�INEER'S
PLANS
a
COMPACTED BASE COURSE-SEE
GEOTECHNICAL REPORT FOR
RECOMMENDATIONS
COMPACTED SUBGRADE-SEE SOILS
REPORT FOR RECOMMENDATIONS
SECTION A
'1 TUNNEL CROSS-SECTION
o�' 1-1/2"
i 4 �`-''�` 1-0/2"WIDE X 1/2"TALL METAL RAIL
�I
�� F � 1"X1"VERTICALSTEELTUBING
12"MIN. ? � 112"THICK DECORATIVE STEEL
F CIRCLES
0
000
i O ��EP,D � NOTE:INSTALL HANDRAIL WHERE STEPS
12" HAVE MORE THAN TWO(2)RISERS
j �O 0 � 1-0/2"WIDE X 4"TALL METAL RAII
`� I O� O 3"INSIDE RAILS
. i
� � 0 1-1/2"SQ.METAL POST,4'MAX
` � SPAN BETWEEN POSTS
a . _°�..
COLORED—
CONCRETE
STEPS
3�a°=r-o° 3 HANDRAIL
SECTION
�`����'I
`���-� f
►�����
I�I�I.
�_•_•
,�•�•�-
�����•��
COLORED CONCRETE PAVERS
SLEEVE FOR POST(SECURE
WITH GROU�
CONCRETE FOOTING PER
STRUCTURALENGINEER
7"CONCRETE WITH if3 REBAR AT 15"
O.C.BOTH WAYS
—8"MIN.COMPACTED BASE COURSE
❑0
CONCRETE PAVERS
TYPE 2A
COLORED CONCREfE
PAN
�
3'-6"
����
� ����
� �������
'��
� '�
���'�•
e\�i•.� �'�`
r� �i�.
�:��'��f ��Ij
`c� ���
�_�
1�� �i!�,.ii
� ��.�:
1�OVERHANG TYP.
1'-10"
�
3' 1
12� HEIGHT VARIES,
/ REFER TO
HEIGHT VARIES, I GRADING PLAN
REFERTO �
GRADING PLAN
(6 MAX) �—
LAR�ERSTONES
AT BOTTOM �'�{�
FINISH GRADE g a
�—��
���—���—�� ��—
���—���—���� ���
���_���—�� . ��—
���_������ <
2'-6" ���_���—�� °a ' '� ° .. ^a� � _
���—��� ��� '. a .
� �-I I ���� _ e a . ,.
���_.� ., �� . . f=-^
U 1=1 I ° �
� a '. �
ara°=r-o° I 2 I STONE VENEER WALL WITH CAP
314"=1'-0"
STONEVENEER.DRYSTACK
APPEARANCE,DEEP RAKEO MORTAR
JOINTS,NO F�(POSED MORTAR,
RANDOM PATTERN
FINISH GRADE
I HEI�J����D
EEREQUI�UGF�Tt Ll
I�R STRUC�1��1�1�I t C O I
�
SUBBASE-SEE GEOTECHNICAL
REPORTFORRECOMMENDATIONS
3l4°=1'-0"
v�
�
' �
�
ii �
I �
I
�
II
�i ORNSR/DSVffi.OP&R
�, VAIL RESORTS
DEVELOPMENT
G'�MPEINY
evox. coLOxsoo
..�a o..t�
42�40
' ARCHITECTURE
�.�
� rmoas�°��u�a+c
. �rmr.auaueo
��. una��s°�'ow�m�oomc
�..�
��� -
a�u.�mt
���
�c'��°t.Mr.¢�c
PRWEC7 NO:
0{.0.7.08
��
DD PRdNC
OD PPoC�7G
OD PPoCC�
FoR fbNSIRUCIpN
S7'fE
�
�Op
a`�o
ad
—� SITE DETAILS
0
.30'7
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 10/11/2007
Legal Description: ,�,�,-�G _ �2 � Expires . .: 11/28/2006
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY iJNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 . 70
Totals. . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
*s**+�r+***r*********r++r*�*r**��*r��****s******�*+*****�++*++*�*�** FEE S UMMARY *:r*�*+�***ts�*�*r*t��*r*�rt�:rrt***s**+*r***r*******►********
Building------> 10 3,2 0 6.1 o Restuarant Plan Review--> $0.0 0 Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 103,2 06.10 Recreation Fee--------------> $o.0 0 Additional Fees-----------> $724.97
Investigation-> $0.0 0 TOTAL FEES-------------> 2 0 6,415.2 0 Total Permit Fee----------> 2 0 7,14 0.17
W ill Call-----> $3.o o Payments-------------------> z o�,14 0.1�
BALANCE DUE---------> $o.0 0
■***�**��***.*x*+****�*+*********�**�********�*�**«***s►*********r*�**���*v**�*s*s*r*******rs**a*******►�r****�****�*******x*********�«***�***s+*
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Graciing, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit .
approval
required prior to issuance of partial permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
$60 . 00
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Tower.
Additional Permit Fee: 148 .48, Plan Review: 96 . 51 . CIA o per contract Permit tee:
and
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/01/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter f
to
Doug Thompson and Neha 03/Ol/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelE
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
comment
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
no
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No added
valuation.
Additional plan review fee of $60 . 00 due
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor exc
shoring and grading only. Addtional approvals required for building permit.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the construc
a
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
temporary
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi:
approval .
03/05/2007 George Action: PA Building A. This is a partial approval tor
in
footing elevations and the slope of the foundation.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rf
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot Docl
Levelers .
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
*«*.**«**.+.s*:**�*,:.*.*.*.***,*.*s.�**.*+�:*�**.*.*.*.*s+.*.*.*.*.*�+**.*.*.*.*s�*.**..+...***�*.�*�+.+****.****.+*.����::*.*.****�*.*..:*..**.
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plat plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
^ �i
SIGN RE OF ER OR RACTOR SELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 10-11-2007 Status: ISSUED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: H1'DER CONSTRUCTION, INC Issued: 10/11/2007
303-825-1313 To Expire: 11/28/2006
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
***********************+**********************************+******+*********+****************
TOWN OF VAIL, COLORADO Statement
*******************************************************************�************************
Statement Number: R070002187 Amount: $60.00 10/11/200701:48 PM
Payment Method: Check Init: LT
Notation: Hyder
Construction / ck 56939
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207, 140.17
This Payment: $60. 00 Total ALL Pmts: 207, 140.17
Balance: $0.00
*****************************************************************************+**************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 60.00
-----------------------------------------------------------------------------
��� 12 ����� ��
� ���
APPL TION ILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED
Building Permit#.�U6 " �al�
, � 9T0 4,79 2149(inspections)
.;. �
������G rt REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, piumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further ins ections
will be reformed until the revisions are a ro �_ � � Q '�/� (� .
CONTRACTOR INFORMATION D
General Contractor: Town of Vail Reg. No.: Contact and #'
'�o U -- �u �3a� Sal�°fk�'
ATT NTION..__JQ JR,CIiARLIE,GREG,CHRIS VAIL
Contractor Signature:
�- .,----- .
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ —�
PLUMBING: $ MECHANICAL: $ � REVISED TOTAL: $
For Parcel# Contact Ea le Coun Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel#
21U� a �z2 u --�
Job Name: �� , � � 1 �\��� Job Address: 5, , , ��
(n.i d✓�"Z. J �
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: ��� C Address: Phone:
ArchitecUDesigner: Address: Phone:
���.
Engineer: Address: Phone:
0►1 �-/ti
REASON FOR REVISIONS:
Work Class: New Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building;
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No( ) Does a Fire Sprinkler System Exist: Yes ( ) No( )
FOR OFFICE USE ONLY
Other Fees: Occupancy Group: . Acce ted B :
.� �_. , �; �.
Type of Construction
� Da�e,Received: ,_, �, �,. , z ,�-�
F:\cdev\FORMS\Permits\Buitding\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
V
�,�1 � � �1►�Il��inc.
c:t���a��c��
Buitdf3ng Depamnenk Seivices
September 17, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: ASI S-026
PERMIT NUMBER: B06-0018
REVISION NUMBER: 12
INTERNAL REF#: 5441
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Monroe & Newell Structural Sketches: SSK-VBS1 and SSK VBS2, both dated 8/22/07
Plan review fee: $60.00
No additional square footage- No added valuation
Sincerely,
�� �j�
Matthew Royer
� O
Building Official
SAFEbuilt Colorado
P.O. Box 1618
Eagle, CO 81631-1618
(970)328-1790
(877)428-6412
matt.ro�e�SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone: (970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓Z:�Plan Review\Vai1�F'ront Door�B06-0018\tov-b06-
0018.Rev12_FAL.doc
1 w..
4240
ARCHITECT'S SUPPLEMENTAL VAIL'S FRONT DOOR
INSTRUCTION No. S- 026
To: Doug Thompson/ Hyder Construction, I11C. PROJECT NO: 20693.OH
543 Santa Fe Drive issuE�: 08.23.07
Denver, CO 80204 FROM: Neha Khera
303-825-1313 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructioiis
indicates your acknowledgeinent that there will be no change in the Contract Sum or Contract Time.
Architect's Supplemental Instruction Title: Site—Art Sculpture Structural Foundation
Reason for Change:
At VRDC's request, st►uctural designs have been provided for a sculptural art piece in the Vista Bahn Plaza.
Description of Instructions:
See attached.
Attachments and Enclosures:
Monroe&Newell Structural Sketches: SSK-VBS 1 and SSK-VBS2,both dated 08.22.07.
� Copy To: ASI File
BY� Randy Hart/4240
Neha Khera/4240
Submit to Town of Vail: � YES ❑ NO Rick Caudel/VRDC
S. Jarvie}�c�}�t���
S����sih�l��dl�liance to all
relevant Adopted Building and Municipal Codes.
���,� �� ���� Changes in Plans MUST be approved.
� � � Date q �� o� By��,e.•�,�y
��� ��
����,�.�,, +;:,;�> Code: '2.oa S sabe
SAFEbuiit Colorado
��= S1�!1
���. 2
� ��� $ /�
42�40 ARCHITECTURE INC � �� �V�
l
1621 Eighteenth Streex ���I
Suite 200 �
Demer,Colorado 80202 The information contained in this message is privileged and confidential intended only for the use of the individual(s)or entiry(ies)named
t 303.2923388 f 303.29231 13 above. If the reader of this message is not the intended recipient,you are hereby notified that any dissemination,distribution,or copying of
www.4240architetture.com this communication is strictly prohibited. If you have received this communication in error,please notify 42/40 Architecture,Inc.immediately.
.1(T8 ._ __ . .... ...... _.... .. .. .. . .
�p IYlonroe & Newell ,,
�.,��,���t�r5. i����_
��, �T�.,
.
� E: , �,�7� ' -'`
-�-�t--� ����iVlOitur.,,�� r H t i.t t�FF n�iv __ ` ° `
`,�����Q��NS�.�y,9Or�� , �iE hr ;� , _ _. _ a�r
, ?,Q�`�P ' ��
f '•
,;r.t. _. _ -__ _ _.
� •
a •�r= � _ r :� '�
_,,. 1 � . . ,}. ,,_
. . �
� : a � _-, ,.
� � 4 ; � .,
� • .. -
r ' <(I:O r. ,. _ .. ._ r. �, p . , . ... .
\ , . ,. .. , .' 7 .
p • Y
N� N��Q �
t
E '
9A ��NA� ' P�� r. f� r. - �
•,, � �-�.� =
� .
•�..,.....�'�Q`���� � t`_� ; , ,
��0j��:eC�#����,� , _ .. ,
�, --
4.�... - 1.� e�:. .. . 4 v . ',.
.�` � ..... . .. . . ... . .. . . . .
V
� � � � ' , i ��r 1'� - �
i' � �j ... . .. ._ .
! ... . ,4._.._ �•w; .... . _... _ .. _... . . _ ,... .;�'� i .._ , . ��.,
�..!v �. .. � .
._4 ; �. .. . ...... . ..........�" -' , �" �. �.�.,N� ,:
;Y 1 , ._h.
�_. ' . ^�t� -t-.i' , � , , r..
_.._ � , -,�. .. .—' `
.� �.. , . �+r�f
_. . . � . -� r yj ..
`, 1 F't_; ., t
� �
Ft I _..__ . , rY:;.
9
�Tr .,�.. ..,„......
is --_•_ _ _
�- � `: � ` ��VI�W�D BY
, �., . _
��� � � ����
1
SAFE�ullt Calorado
�� „ _
� „
. ..
. _ _ ; <, ,r r - �
,� ;�. .
, __ ; � :
� . ., F� . ;.`, , i , . + �.. , � �, .
7
l�,�� �1�..�:�'7,- :..: (..�.: f� ." � �..� i-. .
. _, i _ . . 6;', '.s
,
_ . i . } .
. : 4y .
, ��� `'t -SLS��i>�� �: �=�' ,�- , _ , �
_ ,_
i, ,
;. . � ti,�
r ��";,, � a, , �t' ,, . ,
,f�;�'al.� rY', . , � ' ,
� a� 1
` :t. . �� }: -1�,f 1i(l.. { ,_ �. _.
t
-; •..
+ ;k�A.Y �'�_ P t n._ t '� � ,
� .
�;r .. �V�.7 I . . . . . .. . �� � � . . .
1 . ._.. .. .�� � .'..S_.. . .. .. . . .
� Mc�rlroe & !������ell
.. „
._ _ _
���z�tt�it�c ,�rs. it�,c�. �
,
�_—+_.�� � , . . r
,
yu• I�-, .. . �. '�:_. .. ... .. . ���� ( . �' ' .. .
;,i i
-�o�o�„�S r�n�s�- 10.� a..� -�os�t De p� i . , :• ,;
; �y , .. ; , � , .
, � �
. �
_
�. ,
. ,. �,: , �
_ , . . ,
, cr � ��- '� �'c , � � � � �
__ _
' , �o
,, „ . __...,.... ._ _._
��� � �� ..,�.v. h._,.,n...... .T.:�A«.�.r�, .�r, .,.,c� ..�.„.,..<,,.. ,.,.,.. w, ..,..�.... .�r.„.... ,,,.,�..�........ ,. . . � .
�- , ., ....�._ ,.._.-
. . . �:;� � .. �'� �
� ��. �� _. .`:�... . . � .�..... ..._. ,..-'_... . .. ,.. . . .
_ ._..�. ._..,........._ .....____ .. �._..,...... ._ ... .. _.. .
�
,'- '. � . . . ._ . . .._...... . .... . . . . �. . . .. . �
x _. _
_ ,
��. ... . � . . ,.
;
}. . . .. .. ,_..
�
1lg� Z _
,�_ ,
��1/ 1A'[ - _-
V I�M Y 4�4� 4�\i �����,,NALD f����'�i
�
_ - .T.�. `����,Q��-«.+..ON ��i�
2`���:P��,�STFRF�t9��°�
��!� � i ����� ' f "
= �"__
�:
i.�1 W _
�U•��
N�`�'� �,c>`�O
SA��built Calorado � , �o,v��E.••Q,P•��,
� ���o •�,o
F .•!
''�l�re��C0,8922
� I
`,�v. I 2 ��lo� ��-
���
APPL TION ILL NOT BE ACCEPTE IF INCOMPLETE OR UNSIGNED
Buildin Permit# ��6 " ����
#, � 9,T0,�479�2�1�9(ins'p,ections)
������� � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, piumbing, mechanical, etc.!
75 S. Frontage Rd.
Vaii, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further ins ections
will be reformed until the revisions are a ro � � � � �
CONTRACTOR INFORMATION D
General Contractor: Town of Vail Reg. No.: Contact and #'
,� U _ �u ��r 561��,t�I
ATT NTION Jai JR,CHARLIE,GREG,CHRIS VAI L
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ -�
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Coun Assessors Office af 970-328-8640 or visit www.ea le-count .com
�a,�,�e�#
2/�l d �z2 � �
Job Name: ' )I , ' � 1 �\�� Job Address: 5, ��
UG�( dv►�L. J
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: U��C Address: Phone:
ArchitecUDesigner: ��U Address: Phone:
Engineer: o� �� Address: Phone:
REASON FOR REVISIONS:
Work Class: New Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both( ) Does an EHU exist at this location: Yes( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes( ) No( ) Does a Fire Sprinkler System Exist: Yes ( ) No( )
FOR OFFICE USE ONLY
',�ther,Fees : �; _Occupancy Group � '
Acce ted B : : .
.: .
Type of Construction ,., , ... "� ' .Date Receiyed �� ; �
F:\cdev\FORMS\Permits\Buildinglbuilding_revision_11-23-2005.doc Page 1 of 2 12/8/2005
�
u
APPLICATION WILL NOT BE ACCEPTED IF 1 MPLETE OR UNSIGNED '�i SOC�'�o2cY
Buildin Permit#: _ ,�? „,,'1"1
�� t` �' � ��„� ` , �� �x u.�) \(J"'"
�
�'��'�� � REVISION TO TOWN OF VAIL BUILDING I�1� �� � � � 1��
Separate Permits are required for electrical, plumbing, anica l, e tc.! 1
75 S. Frontage Rd. °���� �,� �a��
Vail, Colorado 81657
***All Revision submittals must incl I 4� 'e d plan . o further inspectio
will be reforme n I ��ri e rove **'"i'OWN OF VAIL���
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
� - - 'SG/ � 4�
ATT NTION: OE JR,CHARLIE,GREG,CHRIS
Contractor Signatu • --.
'`–'Z---
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8�Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $ —�
� PLUMBING: $ �MECHANICAL: $ � REVISED TOTAL: $
For Parcel# Contact Ea le Coun Assessors Office at 970-328-8640 or visit www.ea le-count .co
�.��w � �:��;�
!
Job Name: S � Job Address: ��/ �;, � �
+s 1 �'"ai���i �Qi�.f{ � `!. �
Legal Description Lot: Biock: Filing: � ��� �+
Owners Name: �' Address -��,.. ' �,��: "�y��� ' Phone� �n �
Architect/Designer: Address: hone� ��,
Engineer: � Address: ho :
REASON FOR REVISIONS: `
,� — o�� ����- -T����-� T��� P �.
Work Class: New( ) Addition ( ) Remodel ( ) Repair( ) ��'mo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bidg.: Single-family( ) Two-family( ) Multi-family( ) Commerciai( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire taces Existin : Gas A liances Gas Lo s Wood/Pellefi Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No( ) Does a Fire Sprinkler System Exist: Yes ( } No ( )
*******,t,k**"t*****************'k*** *FOR OFFICE USE ONLY*****�*****'�"��,��*'�`*'"'�"�*,�*"E''`�
�:� ���C��u �91 °.�,.i.�x� ���� .'S;�.r},C�" ��t�b�{� ,.,F rt'°,tt, rFr!�►��1�:�� 7Q'�`�k;� >.a -:r .a�K� ���� ,�� ',�rx s"Ft h t
Accept�d•Bys � � ����r�y � Permit�Fee��''�'��� � �� >�. ,. R�ari��C,�Qe`�$��`� �
Outsourced erms:` } `�`
F:\cdevlFORMS\Permits\Building�building_revision_4-18-2007.doc Page 1 of 1 4/18/2007
424o Town of Vail
_ PY -
E TAL VAIL'S FRONT DOOR
��'P���` E' ION No. S- o38
Subject to inspection and Complia
relevant Adopted Builtlin and Muni�T�al e�gThompson/Hyder Construction, Inc. Pao�ecrHO: 20b93.08
Changes in Pla M approved.
Date (6-ZG--v1 By 543 Santa Fe Drive issuE�: f 1.06.07
Code: Zoa3 I f3�C- Denver, C� 80204 FROM: Neha Khera
SAFEbuilt Colorado
303-825-I 3 I 3 ���� � �� / V 303-292-3388
l
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instractions
indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time.
ArchitecYs SupplementaI Instruction Title: Site-Temporary Toilet Trailer Plan
Reason for Change:
In order to meet restroom quantity requirements,the toilet trailers need to be installed for public use.
Description of Instructions:
Place the toilet trailers(locations established on attached sketches),connect power and plumbing as described below:
Power-See attached cut sheets,the power requirement for the restroom trailers is 110 power which will be obtained by connecting
to existing construction power.
Plumbing-The temporary restrooms are entirely seIf-contained.The units wilI not tie into any project plumbing for water or waste.
A rnaintenance trucic will service the tfiailers daily to provide water supply as well as removal of waste.
Removal Plan-The restroom trailers witl be removed from the site by a truck which wilI pull them down through the project
tunnel and off of the property(see drawing attachment for clarification).
Access-The restroom trailers will be directly accessed from a ramp off of the existing project sidewalk into the restrooms.The
steps shown on the attached cut sheets will be removed,and replaced with said ramp. The Iocations of the trailers will be adjusted
such that the ramp slope is code compliant.
SnowIoad-the Contractor will oversee the accumulation of snow on top of the restroom trailers and will maintain them daily and
as necessary.
Additionally,the exterior elevations have been approved verbally,by the planning departraent in a 2 November 2007 meeting with
George Ruther of the Town of Vail.
A letter of obligation will be submitted to George Ruther/Town of Vail hy 7 November 2007 identifying the removal date of the
restroom trailers.
See attached cut sheet with restroom trailer floor plans indicating a restroom count of 9 restrooms(3 units per trailer}.
Attachments and Enclosures:
____.
_ . _ _-------___�_.
Sketches: Proposed Temporary Skier Services Restrooms Plan and Removal Route �
Cut Sheets: Royal Restrooms 3-Stall Unit
� ;---___
_ ___. -
�
Copy To: ASI Fi�e ; , i '
BY����� Randy�Iart/�4240 � � � � � ` '
, , I
Submit to Town of Vail: Neha I�hera�4240 � �
� YES ❑ NO S.Jarvie Worc��ter 1'�He __, �
� , � �
— _, �- �-.� ,..,� f
42�40 ARCHfTECTURE INC --�------
1621 Eigh[eenth Stree�
Suice 200
Denver,Colorado 80202 �rye�nfortnation contafned in this message Is privileged and confidential intended only for the use of ihe individual(s)or entity(ies)named
t 303.292.3388 f 303.292.31 13 above. It Ihe reader of this message fs not the iqtended reopierit,you are herehy noUfied lhat any disseminaGon,distribution,or copyiog ot
www.4240archicetture.com this cammuniption is sUidly prohibited. If you have received lhis communication in error,please notify 42l40 Architecture,I�c.immediately.
� � �
ii� 1i N='� � '1�, �
�•�� •1�
'�� �• - `• .. f
� � '_
..,. �
�� � �� 'i''"���' ,���1�-'i
� � � ° Rk" 1 L .r��.1i��—�.��.i�
..�-+�ia..-��'..���__ _;.�w.c-�r�•��-s...��a=-- -
-�i�l.:�L� �� �:+�a�..� � ._
,�.
��Ar=1
��l�
o-r �
� ;�,���i
- ,� .
C�) i`��,
� :{ 1
` '� I
��.
7"f.. "
ii�l�i:�'i;i:����
�_
►.--.-�
, .
, ,
� �
� �
\w_�J
�
.�
��n�
I�1
,
,•��,
_�
,��,�
�''� �
� f � 4!
I ���� � � I 1
������ � 1
��
��*:.%' '/
.
_—;i�%� ;,��i
��. �'
�%� __.__ r; . �,
/ `�
1►��i'i��
�� �
f
O,'' ..
..1�� ' ,
`,
�1�� ���. .�
�� �.
, ,`��
s�
`w
�' ; �
.% "'i' '
� /:,: �i�►
.�
��
• \
` ' ` • ' • I
- � - . -
� :� 'il:�l.�;, ,
r�
�r �:`N�.�i 7�ii " �"'�',��!"'� �,:� :�''
., . s
( M ��■ _- :. • .. � .
�� 1� a 'a ��. �*��- � �
�w . � � � 1� 4_,..; �i�=e. . �*�`•"�*S�I --.,�=�y'���/. �_1�
� - � _ ..; t �c��.... �'�� 5.
'i .. ■ , ;,�,�
..� "'�a+�s.�c.°' �i�':„111�- < . a - . .�- � s,���
.s s .��--
���i►�i��-'� . ... _ . . � �—\�!:i,�'�s.�..�.�x'.. " �
��S�
�;;wT -�� �J'•
�l�i `:'� �,.
..� ji £,;�_�
'�, � t,
�P_ �•"
.,\�
�`J�\.
� � �
��~1
Y"' . �
- . � . ryw�`!�
• � uw'ir :*s,""*`Y.
.ts
��`t
3
F�
�, i �Wf ry �
8
E�
�?
Y
�, tl �
i � n ��
-o� ; .,� � �,.'�' � . i�
+T
� > ,
��� � '"�'�`.� /:.
'� ��.� �� ��i�'•� � '
�`'�`\, .�+,;�v �;� r ,.
\ � \�.� Y' �.' '� , � k
-�r�.. �"'� "«i �t�i ' . � t} ' .
� d z�
l_.\.� .., ,. .� �'. s ��}.,�.� �
��' �. ��°�_"
.
���`,�`;
�r�� -
���
.. �
�
:, -i�:,�
�
�_�,�-
, . �`� ����S�� N � l� � N�
��
e��c�W
0
A regal porta6le restroom experience.� �
't't�e'��yal Restroams Three-Stall Unit is perfect for `���'� ��,� �'
a�et�r�tm4dating larger groups of people and minimiz- ` ��
�rtg t��rt�m wa'rt time. This restroorn unit is a � ' �,�:,
�+er��# c�t�ice ft�r large weddings and business �� .�,� �*
�: .. ` �
i�t��s �r�d ma y be combined with additionai R�;� ; � :
���±at�ts; to serve events such 'as f�stival� � ; : { �a" , :
�����. The Three-Stall Unit is al� i�� �� ;
,�� ��e in need during emergenc}� si��i��
�" ��f effo�ts, ��or in any ca� wtt�r+e ,
`� � �urces are not readily av�ilabl�
� �,� �
� ��
� � �
� �� i�estrooms Three-Staq Ur►i� 1a�[�a�` .���� �.� �� � �� � ��u. �x ���r�� �, �� �� �
� .
��� ��� ; $ m furnishetl with a sinl�, tai� ��:��`* '` �i�1f��t��gs��p►�i����° ; ������t��r��
� � �� ���� #�a�� restroams eac1� fu�� ° ��� � � Emergerrcy Situaticrns•Business Remadels
��� ����. .�lthether used for a s�e�� �^ � � � D�s���� �� > x
s <� � , �� ��� _b���.� y,��h� ��••,. . ���.�: , �������m�,�:.� .
� b ;5�t�'��sr�, Royal Restrt��s p�� � � ���
� � '
sr� � �� fi� �mm�orts ofi hom� '�i� ���� �� �� ��:: �.
� ��
�,�. �� �
�,� r, r s�i��s�eaturin9� ��������°��
� , � ���
�k� , t ����� ��� _������
� � �� .
u' 3� '' �E�sl�in PorcelainT�ik�s ����, ��°
��� 9 A �� ���
������' ��wi�h�unning'�#�' "� ���� �
�y � � � a �
"�'� r7 ;�Hot water optior�t�' ��� � � '
�- �' �`�` � �,
° ��°4�`�f �/anities and Mirrar�� , � '
�� ��p and Hand Towel� ` �� �� �' � ,,�
� '
�� �t��on�litioning or H� � �' �� ��� � �`
� �
,� ��:� � � ��� �,
����� � �� L�aw Levei�tJutdoor lrg�� � � ��-�„� � >�� �� � ��
��� �� �u n � Li ht�Indi�ta�s ���x����� �''� ��
�s��G��� p� cY 9 = � �
�,: .. . "u 4v�,'� ?TS;� .
�: �������Ha��rails and Low�ntry 1�t��`dr� �� � � ,
������ ��� I��g�, Pictures, and �Et�u�� ' ����� `�
�,�� "�te F�traous Rayal Restroom�(�ni� '����
�
� ����� �� cE�s€�n of��Rayal� Restrc��rris ,�i�� � �� ��;
��; � � � �_� tn g+� �irtual�}r anyv+rta���. '�"�� �� �� ��,
�h , 0���;�ornp�e�ely seif-contain�d ant��� '�� ��� � �"� � '�� + •�
�;� � � �,����olt�u�et or generator�����f�r�Ft� � _
� `�•'�
� � � ° o
���;�on�i�oner. Water is s��p[��+d �� ;: � ��
� ` ^ :hose ar a f.25 gallon, o�t #���i��� y �� � . .
= d, startk. The unit hauses'� 45f?' .<
���� �
� � holding tank. ������� ,�� � � �..
� :���� ,'�� � � ?+��,� �i,�� ; � ' ' �
� ��i��� ��clude��daily, weekly, ar� i ; � ' ` t, �� � , �� ��
� � .� � , ,
� �;�r�erators, additional fresh w��� �
� �4 V �� rest��m attendant. (���ritar �" °� ��� ��j �
� � ���tat inc�uded in renta{.) i�r��i�� �� � '�
�C � . � � �' �' C�' ti
�� k ��Y t�e .obtained by contacting ;,��r�� � ������ � ��
� � . .. . . R E.� . ' . .. .
��'�oms o�ce. Length: 20' (inctuding trailer tangue)
,�J¢x � �1 Re�firooms of S�1t C�l�e �`4 Width: 12' (stairs down)
Y �.
���{ Fhone 801-574-57'33 ` { p � Height: 10' 6"(fr�m ground to top of A/C unit)
����� E keCity�RoyalRestrc�c►rns.t�� �: ,'
�� �ww.RoyalRestro�ms,corn ���-���.��,_ � � - .
V��eelchair accessible portable restroom rental service for construction sites - United Site ... Page 1 of 1
� �� �.�--�-� �
§ fl
��:,
��1"�+�� ��' _. �
:,�:,. _;���� � i �� �� ii� � i `' � � ,�
����� Home a Constructiur> Products>V`Jhe�l Chair Accessikle Restro�n7s
� � ��������� Wheelchair / ADA Restrooms E,,::=k. �3�.�� Y�`� � �R�>:�A`�
� E United Site Services offers a!`Uhealchair Acce.ssibie Resiroorn and � �
�� � ���� an ADA Goinpliant Wheelchair Resti�om, boih are��les��nzd to
` `� � sup�ort special ��eecls indivi�u��ls They ofifer a sp�cious inierior
needed for easv�no��emenc,v✓ith handrail auppo�rt for assisteci
�� ' '� + � n-�ovement. ��.- ..
����� ` •
WhaYs the difference
" " between a standard
Wheelcl7air Accessible
���•��� �� . � + • Restroom and an ADA
Fnt���u:.n��p ��e io t�nd our Compliant Wheelchair (click to enlarge)
ne;artst lucation or Io r,�el a quole f�QStfO0Y77?
� l�here are i-nany consde��atiens
�� invc�ved in the piacement�nC
si�e�f the toile�L accessories
������ . ��� �� aroi�ncl the re�trcom ancl
hai�drail. e1c. that denve frorn
��M . lhe ADA Standards for
�.��� �. Accessiple Design a���eTe��mir�eci by the Depaitrnent o;Ju:i.ice.VVe (click to enlarge)
United Site Services, Inc. supply the ADA compliant wheelcii�ir restre�rn io meet th�
� The USA's largest provider of i�ECessary reauiations fer�vour joI?siie ur�pecial event. .
po�table restrooms and
temporary ience„storage.�ower "I woufd like to take a
ar7d c�ther site services. ApA Wheelchair Restroortt Dimensians:
Height=9C.7" mon�ent to ex,c�ress
my srheere
Width = 7T'� recommendatiw�anc�
Depth =r T' gratitude ta United
�eat Hefgf�t'_ �18" �C�j , Site Services T��eir
�� �ne executior�of therr
�J� contractual duties and
� oblrgations was of the
� v`� highest quatity a:ad
O profession2lis;�t"
� �� _�i� ' K. Luther 7ankersley
�^`,,� � '`7�v Associate Directorof
F� �J Properties Facilities&
Administration
O�tv �.. , s
�.�
Special Events � Restroom Trailers �Constructian �Seasonal �Emergency Services
� Contact us now for a free quote!
��Copyri�ht 2�J07�Friva�y Poli:y�Site Mep
http://www.unitedsiteservices.com/construction/products/wheelchair.html 11/15/2007
L'nited Site Services :: Products Page 1 of 1
/� �
- ��1"��'C�
.�;�..
construction ada wheelchair portable toilet interiar
_ #?
� �;
;��
�-�` -
�- �
� = � �
�� ,�
,
�
� .._
��'- � .�.. � �:
�.
:. � � . �
� '
�=
�
�:x
x:
��; ��•� �;'
,3 x �
� f
��# ' � � �
� � � � �
.� � �
, �
� ���,����'� �. r�r!„ I ��;
� 4j�� k;�,�� �, �`;�
��� � �;.
,�.
� .� _
�` ,__ `�
C!f��f
� �
http://www.unitedsiteservices.com/imagedisplay/display.html?pic=adawheelchair&title=... 11/15/2007
Page 1 of 1
� � � � �
�:
� ����� �'� � �
�� � �. '
��, � ' � �� E '
�
$ ,
. �'��"¢g,� � ri>�,,_ '•y6g` #
�; �, �-.; � �e f i
�� E��� �a.�. � ���� +
e���iAn�������
' s � �' s,.�.
i �
�. li ;.�1 i�yi`I�
„
i �� .i
http://www.unitedsiteservices.com/imagedisplay/products/wheelchair.jpg 11/15/2007
� � � �
b�il����.
��� ��Aa�
Building Department Services
November 26, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Front Door-ASI S-038, Temp. Restrooms
PERMIT NUMBER: 606-0018
REVISION NUMBER: 14
INTERNAL REF#: 6037
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Site plans and cut sheets for temporary restrooms
Plan review fee: $120.00
No additional square footage- No added valuation
Sincerely,
��
Matthew Royer
Building Official
SAFEbuilt Colorado
P.O. Box 1618
Eagle, CO 81631-1618
(970)328-1790
(877)428-6412
matt.ro�(�a,SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓V:�Plan Review\Vail�Front Doar�B06-0018\tov-b06-
0018.Rev14_FAL.doc
� �
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : REVISION
Location.....: VAILS FRONT DOOR-SITEBUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 02/06/2008
Legal Description: �Z-�� _ p��$ Expires . .: 06/17/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202 ,
License : C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License : 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 . 70
Totals . . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
�+*�**�r***�**«�**►**x*r�*r****�+**rr*****x*r******«**+**�**�*r**�+a FEE S UMMARY �**��*+*s*�+r**�***rt*�++�***«****e****s****rr*a+*t****�****
Building------> 10 3,2 0 6.1 o Restuarant Plan Review--> $0.0 0 Total Calculated Fees---> z 06,415.z 0
Plan Check---> 10 3,z o 6.1 o Recreation Fee--------------> $o.0 0 Additional Fees-----------> $844.9 7
Investigation-> $o.o o TOTAL FEES-------------> z o 6,415.2 o Total Permit Fee----------> z o�,z 6 0.1�
Will Call-----> $3.0 0 Payments-------------------> 2 0�,14 0.1�
BALANCE DUE---------> $12 0.o 0
***rr.�**�***:r*+****+*�s.*+**�.s�+*+�*�*a«**+�**+.�r�+**��*++***r*�**�*.*.��*���+�«.��****�*��+�+*�*+*r�*r**��*�**+r+.**r+«:+..*****+**+*�***++.+
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit .
required prior to issuance of partial permit .
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs .
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RF.I No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 :48, Plan Review: 96 . 51 . CIA o per contract Permit tee:
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/O1/2007 MROYER Action: DN Revision 5- Dock levelers . Comment letter E
Doug Thompson and Neha 03/Ol/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelf
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No added
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Rev14, IR6037, Temporary Restrooms approvec
hours of plan review due .
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval tor Shoring System Final ]
sign off from engineer of record
12/27/2007 mroyer Action: PA . rev. 6/ir3089/ steel deck claritications ap�
issued. no additional fees .
Ol/17/2008 mroyer Action: AP Approval tor Rev #7 3090 Elevation and Slo�
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter trom Koechlien on Spf
Inspection and Letter trom PCL on adjacent building monitoring approved. No ChargE
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor ex�
shoring and grading only. Addtional approvals required for building permit .
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the construc
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi:
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI 5-038 TEMPORARY TOILET TRAILER PLAN N/i
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rf
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot Docl
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
*�*+**+����+.*+*�*+*��*,�:*��**�*****�*�.*..**►*..*�*.*r*:....**.****,..*■*�*..�...�..*.*�+**�..*�.*.*..*.*.***.*.*.*+***►�**�*.�.***:+�**:».*.*.
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVAN�B��'ELEPHONE 479-2149 OR A OUR OFFICE FROM 8:00 AM-4 PM.
� � _
SIGNAT � OF OWNER OR TRACT OR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 02-06-2008 Status: REVISION
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 02/06/2008
303-825-1313 To Expire: 06/17/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
.. � .,. w. __
Ca��T �
• .. . M �. � �J
Z
APPLICATION WILL NOT BE ACCEPTE '� os�COMPLETE OR UNSIGNED
Building Permit#: L3�-C�OI�S
! �, ��' �O � 970-479-2?49(Inspections) /
������V+i� � REVISION TO TOWN OF VAi�y BUILDING PERMIT _
Separate Permits are required for electr :al, plumbing, mechanical, etc.!
75 S. Frontage F�d.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of`�pproved plans. No further inspections
will be preformed until the revisior.� are approved. ***
CONTRACTOR INFOR��IATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
�r' C-0 ��'�...C.. � C,. 1 ���� �r C c' f cl L-i�-G-�s 1
ATTENTION: JR,CHARLIE,GREG,CHRIS
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ELECTRICAL: $ —1 OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
r
For Parcel# Contact Ea le Ccaunty Assessors Office at 970-328-8640 or visit www.eaqle-county.com �
Parcel,� �IG I��S �21U��
Job Name: . � Job Address:
VU� I s ��^�` 'Qovr 1`�l U�,I L�,,e--.
Legal Descri�tion Lot: . Blocic: Filing: Subdivision:
Owners Name:v�; � Address: Phone:
(IZ��r-rs
Architect/Designer: Address: Phone:
�--f�.-/�i v
Engineer: Md„rae � e,{� Address: Phone: �
REASON FOR REVISIONS: L ��JN.�.�^ {, s�o�c ���-�,b,� �U1- ;�`�e..�
Work Class: Nev�d,� Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( ;
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/Type of Fireplaces Existing� Gas Appliances ( ) Gas Logs ( ) Wood/Pellet( ) Wood Bur�ning ( )
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood �urning (NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
FOR OFFICE USE ONLY
Other Fees: : Occupancy Group: � [-Accepted Byr:
Type of Canstcuc#ion: ' (—Date Received:; �
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
.
` LETTER OF TRANSMITTAL
J���� No. A0239
CONSTRUCTION INC.
543 Santa Fe Drive,Denver,Colorado 80204
Phone:(303)825-1313 Fax:(303)825-3223
Email:info@hyderinc.com Website:www.hyderinacom
TO: Town of Vail DATE: 2/14/2007
PHONE:
ATTENTION: Joe Suther
PROJECT: VFD Site Work & Bldg A - Garage/Dock
HCI Job No. 26006
WE ENDING: UBMIT R• A T ON T N:
❑ Shop Drawings ❑ Approval ❑ Approved as Submitted
❑ Letter ❑ Your Use ❑ Approved as Noted
❑ Prints ❑ As Requested ❑ Returned After I,oan
❑ Change Order ❑ Review and Comment ❑ Resubmit
❑ Plans ❑ Submit
❑ Sam les SENT VIA: ❑ Returned
❑ Specifications ❑ Attached ❑ Returned for Conections
❑ Other: ❑ Separate Cover Via: ❑ Due Date:
ITEM NO. COPIES DATE ITEM NUMBER REV.NO.DESCRIPTION STATUS
5 2/14/2007 ASI A-015 AAN
cc: Signed: v`
Greg Perry
V 4240
ARCHITECT'S SUPPLEMEfVTAL VAIL'SFRONTDOOR
I NSTRUCTION No. A-oi 5
ro: Doug Thompson/Hyder Construction,Inc. �o1E�T Na 20693.08
543 Santa Fe Drive ISSUED: OZ.O6.O7
Denver, CO 80204 FROM: Neha Khera
303-825-1313 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructions
indicates your aclmowledgement that there will be no change in the Contract Sum or Contract Time.
Architect's Supplemental Instruction Title: Bldg A—Structural Dimension Clarification#2
Reason for Change:
Clarification of dimensions,elevations of top and bottom of beams,top of slab slopes(including slab at roof of north parking
structure),and concrete beam layout including RFI information up to 01.23.07.
Description of Instructions:
See attached sheets for additional information.
Attac6ments and Enclosures:
Monroe&Newell Structural Sheet—S 101,S 101.5,S 102,S 103,S 104,S 105,S 106,S 107,S 108,S 109 and S 110,dated 01.03.07.
� � 1 Copy To: ASI File
By: Rick Caudel/VRDC
Greg Leuchtmann/Monroe&Newell
Received By: Jim Ness/Monroe&Newell
42�40 ARCHITECTURE INC
1621 Eighteenth Street
Suite 200
Denver,Colorado 80202 ����ti���eined in this message is privileged and confiden6al iMended only for ihe use of the ir�vidual(s)w entity(ies)named
t 303.2923388 f 303.29231 13 above. if the reader of this message is rwt the intended reapient,you are hereby rrotified that any dissemina6on,distribution,or copying of
www.4240architecture.com }►��s communication is stridly prohibited. If you have received this oanmunica6on in error,please notiy 42/40 Architecture,Inc.immediately.
.
������, '� Hyder Construction
January 29, 2008
Revisions ready for pick up. Doug Thompson has been contacted. These are the fees
due:
Fee
Item#
�M���8° �M R���t�n`'�, el�vatiort, antf �lop elevation clarification $ 0.00�
B06-0026 Revision 5, ASI E-053a, buyer revisions Unit 6A $120.00 81
FEES DUE 120.00
�
� �l�l��,nc.
c:o�c�€��r��
Buiidutg Department Services
January 16, 2008
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Vail's Front Door
PERMIT NUMBER: B06-0018
REVISION NUMBER: 7
INTERNAL REF#: 3090
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Elevation, and slope elevation clarification with ramp detail at loading dock.
Plan review fee: $0.00
No additional square footage- No added valuation
Sincerely,
Matthew Royer
Building Official
SAFEbuilt Colorado
matt.rover(�a,SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free: (877)428-6412✓Fax:(970)328-1791✓\�Eag1el�Eagle Shared Drive�Plan Review�Final Approval
Template FAL.doc
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
��t'�SvCa UU4r�S
Job Address: 174 GORE CREEK DR VAIL Status . . . : APPROVED
Location.....: VAILS FRONT DOOR-SITEBUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . . 02/06/2008
Legal Description: Expires . .: 06/17/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 . 70
Totals . . . 108, 815$27, 739, 000 . 00*
Firepiace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
**r�*���**�**r*+***+*******r******s�*r*******v*rr*+*s***:r*+r***++*** FEE S UMMARY *********�****r*****s**a�*�*r**�*�srr*s*�*►*rs*�**��**►*�+**
Building------> 103,206.10 Restuarant Plan Review--> $o.00 Total Calculated Fees---> 206,415.20
Plan Check---> i o 3,2 0 6.10 Recreation Fee--------------> $o.o o Additional Fees-----------> $64 4.97
lnvestigation-> $0.o o TOTAL FEES-------------> 2 0 6,415.2 o Total Permit Fee----------> 2 0 7,2 6 0.17
W ill Call-----> $3.0 0 Payments-------------------> 2 0 7,14 0.17
BALANCE DUE---------> $12 0.o 0
******�*s**�***�+t*.**�+�a�**�**+***+*+*�**+*�***e**�*r**s***as**w**s�*�:**.�*+r+�»ar****+*s**+er+�****�++���***v*t**r�*�sss�:str***+*�*«s���rrr�
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit.
required prior to issuance of partial permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 .48, Plan Review: 96 . 51 . CIA % per contract Permit tee:
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/O1/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter E
Doug Thompson and Neha 03/O1/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelf
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No aaaea
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Rev14, IR6037, Temporary Restrooms approvec
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval tor Shoring System Final l
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck claritications ap�
issued. no additional fees .
O1/17/2008 mroyer Action: AP Approval tor Rev #7 3090 Elevation and Slo�
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No ChargE
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#6133
03/24/2008 nchand Action: AP Approval tor ASI-5041 IR#6556 B06-0018 REV
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections by 1
Engineers have been received and are ok. See SAFEBuilt letter in tile dated 2-5-0;
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor exc
shoring and grading only. Addtional approvals required for building permit .
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON7
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the constru�
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi;
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI 5-038 TEMPORARY TOILET TRAILER PLAN N/i
02/19/2008 GR Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No Charga
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
02/14/2008 McGee Action: COND Provide detailed plans tor gas shut ott to:
heaters .
Provide detailed plans and new mechanical plan for fire pit.
Provide review by BCER tor tire exiting due to changes in sidewalks per original �
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant .
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rE
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot DocJ
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
+.�.*+**++�:+�*.+«**��***+�*«*.�..*.***.*s*.**..*�*+**:**.*+***.*.*+..*+�**.*.*.*.*.*.**.******,*�,*.*.*.*..+*.*s*.*.�*�***+*...*.**�+.*.*..***..
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
/
�
SIGNATURE OF OWNER CTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 03-27-2008 Status: APPROVED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 02/06/2008
303-825-1313 To Expire: 06/17/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
�m 3� ��
��� �: � � �� �rl�.
t..(�L.'��h U tJ3
Building Department 5ervues
February 05, 2007 � � �
Charlie Davis �
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Front Door—Special Inspection, Structural Observation
PERMIT NUMBER: B06-0018
REVISION NUMBER: 17
INTERNAL REF#: 6346
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has received the final summary for the special inspections performed at the
Front Door project by Koechlein Engineers and the monitoring of the adjacent buildings by Peak
Land Consultants (PLC). These letters appear to be in order and the office and field copies have
been returned for filing purposes.
Plans:
One letter from Koechlein Engineers.
One letter from PLC and Overall Building Monitoring
Plan review fee: No Fee
No additional square footage- No added valuation
Sinc�ely"",`...
\
�''
John Plano
Plans Examiner/ Senior Inspector
SAFEbuilt Colorado
john.plano(�a,SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit]O1 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓F�:(970)328-1791✓V:�Plan Review\Vail�Front Door�B06-0018\tov-b06-
0018.Rev17 FAL.doc
' . r
Koechlein Consulting Engineers, Inc.
Consulting Geotechnical Engineers
� 12364 W. Alameda Pkwy• Suite 115 • Lakewood, CO 80228-2845
www.KCE-Denver.com
LAKEWOOD AVON/SILVERTHORNE
(303) 989-1223 (970) 949-6009
' (303) 989-0204 FAX (970) 949-9223 FAX
December 12,2007
Rick Caudel
Vail Resorts Development Company
P.O. Box 959
Avon,Colorado 81620-0959
Subject: Summary of Construction Observation and Testing Services
Building A, B,C, and D—Vail's Front Door
Vail, Colorado
Job No. 06-050
As requested, we have reviewed our construction observation and testing reports prepared for the subject project. The
purpose of this letter is to present a summary of our construction observation and testing services for the subject project.
The following table presents the construction observation and testing services that our office provided for the subject
project and our conclusions with regard to these items meeting project specifications.
���m�t3�+' ���
Subject to insRectiort and Compliance to all
relevant Adopted Buil�lin and Municipal Codes.
Changes in Plans lIS pproved.
Date �5 �_Ey .d
Code:�r�L
SAFFh�.,ilt Col�r�.��!c��
--_ — -._
REVIEWED BY
�r�_�,. . ._..
� ; �'�,� � :y� �QO�
�
�
� �_ -------
, �I __.
SAFEbuilt Colorado
�----___
_ _______..,___—
� Ric1: �`audei l�'OECHLE/.��CO.��.SC�LTL��GEV�Gl,���EERS, /��G
Decemlier I?. '_O07 Co�rsulli�t, Geolechiticnl E�rnitteers
Job No. Ob-0�0
Pa�e? of?
Construction Obser��ation and Testin<� Services Performed Compliant��ith Proiect
;
S ecifications'-
� E�cavation Observations Partial'
Reinforcing Steel ai�d Do���el Observations Yes
Post-Tensioned Tendon Lavout Observations Yes
Post-Tensioned Tendon Elon�ratioi� Measurements Yes
Ex anded Polyst �rene(EPS) Foai1� Fill Yes
Compaction Tests(Foundatioi� wall backfill, sub�,rade, interior fill, e�terior fill, etc.) Yes
Com action Observations (�ia-inch rock com actio��j Yes
Concrete Testin�(Structural co��crete—footin�s. walls, columns.etc.) Yesa
� Masoniti� Observations Yes
Spra��A lied Fire Prootin�� Yes'
Structural Steel Observations Yes'
Notes:
1. Observations and tests are considered compliant when the infor���ation within the eonstruction observation and testin�
repo►-t meets project specifications or ��hen sufficient documentation has been provided to Koechlein Consultin`,
En�Tineers, Inc. by the project team to ne��ate the non-compliant obser��ations and/or tests documented in the reports.
2. Compliant observations and tests are based strictly on the observations and tests performed at the locations indicated in
the reports. Compliant observations and tests are only applicable for areas observed and tested as documented in the
reports. It is possible that areas and construction items not observed or tested are not in compliance ��ith project
specifications. .
�. All escavation observations for foundation elements had met project specifications ���ith the exception of the sub��rade
for the footin�� pad located at Gridlines O.0/14.3 noted in Report No. 62. dated 1?/0�/06. How-ever, ���e were informed
bv the contractor that the ice had been rei��oved fro�n the base of the eacavation for the footin�� pad prior to the
placement of concrete. To our knowledge, the footing pad at Gridlines O.0/14.3 has not esperienced any ezcessi��e
settlement or movement since the construction of the footing and erection of the buildin�.
4. All cancrete tested had met the project strength requirement at `?8 days ���ith the exception of portions of the concrete
placed on the follo���ina dates: 1?/?7/06, 2/2]/07. 3/7;07, 3/19/07, and 4/13/07. The portions of concrete poured on the
aforementioned dates met project strength requirements at 56 days.
�. Western States Inspection under subcontract to Koechlein Consulting Engineers, lnc. performed structural steel and
�veldin� and spray applied fireproofing tests and observations as noted i�� their letters dated November 12 and
December 1 l, ?007.
Based on our limited observations and tesiing and the information pro��ided to us bv the desi�n and construction team, it
is our opinion that the construetion testing ai�d observatioi� itei��s presented ii� the precedin�= table have beei� constructed
substantially in compliance with the project plans and specifications.
We appreciate the opportunity to provide this ser��ice. If���e can be of further assistance. please contact ow�office.
KOECHLEIN CONSULTING � EERS, INC.
�O LI T-r'�'
..... �,�, r�
8.
�- O
�� �_�/
��•. OZ���9d� �
~��N��N���
�l
Scott B. Myers, P.E.
Senior Engineer
(1 cop�� sent)
cc: Scott Miller—H��der Construction. li�c.
�;�;_�',�tE;,=�' s~, °d�ra—,
"��[c��C`P�tc1u$ �
�
!,'E�l� }�� 't�tf��; P)a'1'��Ci�71`t181�1 �_��I"Il���LI�' ��
l}'. FY��.s��� l 1zJ1EL LV`•:• � 1 �( � �
�✓ �-"` A.rl — L�l�l!�l�;y 1VEU1TIt��IJ ���'�
G 9`e'.'�.(.• gp�`j.' \
?ealc L���d Consult�nts, I���v f�as be����;ur�i�iioi•i�l,il�e��istin�build;n��s a�•ou3�d your c�ns�t�•ucti��i��rojzct�il��ou�l���ut
e�;cavaiio�l�nd�ti�e t�aci:fiii o�t ci�e ue��i�uil��iina,�o��e�i#y ai�y tl����eilie�t. �J�f�ave moniior�d tl�e�(�ollo�vif�g �
�liii��lii�S:
O�le Vai] Place
The Hill Building
Lod�e Tower South
The Lodge Internationa]
Riva North and South
The Willows
The suivey monitors began August 3,2006 and have continued to November 5,2007. During this time we have seen
no noticeable movement from the original location of these sh-uctures. I have enclosed a copy of the latest Monitor
Report that show's no movement other than what I feel is Standard Survey Error. You might want to consider
discontinuing tlie monitors at this time since the all backfill is nearly complete. We could do a tinal monitor in the
summer of 2008 for one tival check if you choose.Please cuntact me on this and let me know what you feel is the
best course of action.
Sincerely � ��t���qSTF �''/�'"
' �!"?�' q�00i�� F/' ,�
��s•o���Z g�,'�F�j �„�- .-
�.�: ,.�__ �..r--�..
�, f
Brent Big�s . O �'' c�� � �=
Peak Land Consultants �,: �� "' �°
o e �y,
Fresident �i��° �l�j 6��
kr�,�aov � �ob ���
o �
'``�fi/U%�?L�Lj;;,'•,;0
APPRCI�'''��
Subject to inspection and Campliance to all
relevant Adopted Buitding and Municipal Codes.
Changes in Pla ,be approved.
Date Z-S—o�By
Code: �'c�o3 1'.�C
SAFEbuilt Ct�lor�d�
._...._.�
� R�VIEWED� BY
��_?._____
Ir—,.,;. Q.t ._ �
� i ��.� �,:� ���
,
� .__---_______.._.__._.___._
` SA��4uil� Colorado
I _ __.�.._ _.___.--
_ j,:;.-.. .
N � Z
� _ � W W W W W W W N N N W W W W W W W W 'O
C m o 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .-�
0 0 0 0 0 0 0 0 0 0
> ._i 1 �..a 1 �
mmcn rv -� o -pc�.� rncnca .PCnc,.� n� � o � rncn .A �
O �
D �
O � � � � � � � � �l � �i � i � �i � �..1 �
� S � � � � � � � � � � � � � � � � � �
\ � � � � � � � � � � � � � � � � � � O
Z O O O CD O O O (D CD CO CO CO CO CO CO (D CO (O Z1
0 � O O O CD O � � 00 Oo 00 CO CD 00 00 OD Oo 00 Oo � O
� C OD --> N �I Ut O � W 00 00 --� O (D 00 CO �l 00 �1 = �7
r s .P CT � O � W N N^ N W A 0^o A N A O (Ji /\
� � � � � � � �l � � Y� ' � �..� Y N � � � � � V J
N � CO � W N �l N � W -� �1 CO N N �l �l � � Z
� Z �. -� � �A N (fl -� W CO Ut CO 6) CJ� � 00 � N �A
m � �
Dv �
�
D N N N N N N N N N N N N N N N N N N C_
mcn � � � � � � � � � � � � � � -.� � � � m �
cn cn cn cn cn cn cn cn cn cn cn cn cn cn cn cn cn cn
� 0 .p .r� � � .p �.. A � .p � cn cn cn � cn cn cn cn D <
R7 .P -P �P CJi �A � �1 �I Oo 0o s O O cfl W N N -� U1 rn
Z � Ch � O Oo Oo W W N CO -� � W 00 O � � �I -I '�
0o co W rn oo � � o N � o0 00 .P w co c� oo � Z C7
� O in � iDOOO> cn 'o� � ooi,� ioina� oioioiaiv � y
j �— -� rvivc� n� aowcaoo � � � � -� � -� -� .t� --�
< = ao � cfl cn rn .p iv v o � cn w c.4 � � w cfl � m
�v � o0 00 0o ao 00 00 00 00 0o w o0 00 00 00 00 00 00 00 �
D � � � -� � -� � N N N N N N N --� � N N m G�
� Z wrnrnwoo � � � j000 � oowoorc_
z � � Ui �A O� Oo 00 00 �! �I �I N W W N Cfl Oo O -�
Q IV O CO .P �P � O� �l Oo 00 C.n CO � � O W O (D C C-�
� (Ji 6� 6) �I W c0 � CO N N � � �l N CO Oo Oo �A •
� O � W OD Cn �A CT Ui ? 00 (3� � N N t� A Oo CO W CD c'�
N
Z r � � � �1 � O
<n� � � � � � DDDD -ri -rl -�i = = � -' z O
� = O � � tn cn Z Z cn v� cn r r r r r. r « c <
o m � ooOcc � � � o�o � '� wn� =� N � �n�i � z �
o m � � N � xxxx �c .i � � _
o Zm N � N �
; � � W
.P D 2 —
c;' oo O Q
� r
o m .� 3.
� �o �
o �
a m °� wwc.owNNrvwwwwww w -o �
� � � D D D W N w w 1 W � w W w c�,.� � w y w � �
� _`-' O tD N W �1 00 Cfl �l � (37 A O CD 0� �k
� 0 O
-ti �
� � > �a �a � � �1 � �a � �a � � �a �� �f �/
� � � � � � � � � � � � � � � � \
� p Cn � � � Cn (Ji Cli CTi Cn Cn U� Cn CJ'i CT � —
�p (O O O O (O (O CD CO CO CO (D (D Cfl CO �
j � Z Z Z � (n O � 0o O� 00 � O CO Oo CD �1 z � � (n
o• � D D D rn o rn w N N n� c,.� � ao � r.� � D cn ? C �
� 6� �I s �I �I i� � 6) C3i CT N O � Cn Z � �y,
� �! .P � p� -a � N -a �I O -i N � Ut � � �
W 6� Oo W N O � � 00 � W Oo Oo CO �
(D
v
� N N N N N N N N N N N N N N D
� � �, � � � � � � � �, � � � m
� cn cn cn cn cn cn cn cn cn cn cn cn cn v� --�
� .r� � � � � .A � cn cn cn +� cn cn v, N m
Z Z Z v� .t� � � -.� cx o� � o o �� c.o iv �
00 00 � w w n> c� -� rn w o0 o rn y � -1 Z
o DDD � oorn � oiv � aoco � cacflcfl -� Zp
�
cfl a� cn rn � w ca �o in rn o io c� iv �
x owrn -� .A � ow � cfl -• cDC� cn � m
C �I CO C9 Oo 6� N �l 0� C� N -� � Cfl CO �
X W
�, w o0 0o w o� oo w o� o0 0o w o0 00 0o m
� �i � 1 �1 �
N N N N N N N m
Oo 00 �1 �I � � -� O O O � 00 Oo O r- .Zl
Z Z Z pp pp pp pp v �1 V N W W N CD O� Z m O
D D D � :p j� o> o� bo bo in i� a� a� � i� � io C cn
�I W 00 � O W N � �A 00 .P j O CJ7 •
J� � -� � O N N W � Cfl W CT �I O O
O
� � � � � �
� � � < < < < r r r
D D D D = _ � � �
� � � cn tn z z c�i� c�n ai r r r r � � < < c
0000000 � j, ,� � �,, �, � rr � � �
c� � � cc � � �coo � ,G -.• n> � m
-1 -I � -I cs ti �
W N j 2 2 = 2 -1
� � . �
N j N �
O O � � � � � i � � � � 2
O O O O O �'1
Z Z Z p O O O O O O O � � O 0 � D � = Z
D D D o � o 0 0 0 0
co .P � ao � c� cfl cn iv rn � o w cn Z m
�
0 0 o a o 0 0 0 0 0 0 0 0 o D =
z Z Z o 0 0 0 0 0 0 0 0 0 0 0 o D o � Z
� o -• o � -� �
D D D N W � � � o°o °� w rn w rn � 1 v' Z �
G� m
n
0 0 0 0 0 0 0 0 0 0 0 0 0 0 � _
z z z o 0 0 0 0 0 0 0 0 0 0 0 o z o m D
D D D o o � o 0 0 0 0 0 � -� � j D o � Z
--� N ,p � N �l j � Ul W CO � Oo N �
' m
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
��s6� ��� ���
Job Address: 174 GORE CREEK DR VAIL Status . . . : APPROVED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . : 03/27/2008
Legal Description: Expires . .: 06/17/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 . 70
Totals . . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
�►�r**�+�****++*r*rr*t****��***++�++********��*�*sr+****rr�***�***a� FEE SUMMARY *�*r«�a+*�*s*****s*a�*+*+**��******r*r**r**��**t****�*�***►■
Building------> 10 3,2 0 6.10 Restuarant Plan Review--> $0.0 0 Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 10 3,2 0 6.1 o Recreation Fee--------------> $o.0 0 Additional Fees-----------> $84 4.9�
Investigation-> $o.o o TOTAL FEES-------------> 2 0 6,415.2 o Total Permit Fee----------> 2 0�,2 6 0.17
W ill Call-----> $3.o o Payments-------------------> 2 0�,14 0.17
BALANCE DUE---------> $12 0.o 0
�*******r*r**+►*s*+�**►***r*+r***�*:****************»*****+**r******��**�•r**s*.r:*s***t***e*****�*sr+**:**s****s*++srs*.rs*+*:�*�*+*s*�*****r*«*
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit.
required prior to issuance of partial permit .
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 .48, Plan Review: 96 . 51. CIA % per contract Permit tee:
Plan Review: 77 .21 . Total tee ot 244 . 99 must be collected prior to release ot rev:
03/O1/2007 MROYER Action: DN Revision 5- Dock levelers . Comment letter a
Doug Thompson and Neha 03/Ol/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelE
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No added
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Rev14, IR6037, Temporary Restrooms approvec
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval tor Shoring System Final l
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck claritications ap�
issued. no additional fees .
O1/17/2008 mroyer Action: AP Approval tor Rev #7 3090 Elevation and Slo�
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. l7/IR6346, Letter trom Koechlien on Spf
Inspection and Letter trom PCL on adjacent building monitoring approved. No ChargE
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#6133
03/24/2008 nchand Action: AP Approval tor ASI-5041 IR#6556 B06-0018 REV
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections by 1
Engineers have been received and are ok. See SAFEBuilt letter in tile dated 2-5-0:
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor ex�
shoring and grading only. Addtional approvals required for building permit .
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the construc
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi:
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI 5-038 TEMPORARY TOILET TRAILER PLAN N/i
02/19/2008 GR Action: AP Rev. l7/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No Chargf
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
02/14/2008 McGee Action: COND Provide detailed plans tor gas shut ott to:
heaters .
Provide detailed plans and new mechanical plan for fire pit.
Provide review by BCER tor fire exiting due to changes in sidewalks per original �
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant.
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rf
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot DocJ
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
****.�.*.*..�.�..++.,��**«..:*+*+�*.***:**.*.*►�.�+*.*..�..+.�....*...�.+.++**.+.*.*.+..**.*******.*«**.*.*.***.***�+:.*.+.*.�..*,*..#�*..���*+..
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 03-27-2008 Status: APPROVED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 03/27/2008
303-825-1313 To Expire: 06/17/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPiNG
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
�� � �� �
����lf1C.
�C.}t C�RA[��
$vi�ding Depart�nes►t 5ervices
December 27, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Front Door U��g
PERMIT NUMBER: B06-(�8
REVISION NUMBER: 6
INTERNAL REF#: 3089
ADDRESS: 151 Vail Lane
Dear Mr. Davis
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Steel Decking Clarifications
Plan review fee: $0.00
No additional square footage- No added valuation
Sincerely,
�
Matthew Royer
Building Official
SAFEbuilt Colorado
matt.ro er ,SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓\�Eag1el�Eagle Shared Drive�Plan Review�F'inal Approval
Template_FAL.doc
------
3o g
/� APPLICATION W LL NOT BE��CEPTED IF IN MPL'_T'� OR UNSIGNED - -�,
{ Buildin�Permit# ��,2 -pp��
� � <,�
4 �� 970�47��-x1��¢9��I��pec�4 n�
. # � ,,... . �...�
������� + REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittais must include the Fieid Set of approved plans. No further inspec#ions
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION �
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
I� dcr' C.o� i-r�.,, 't`io�.. 05�- C� r C�i
ATTENTION: d�f�JR,CHARLIE,GREG,CHRIS
Contractor Signature:
� X -
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ ELECTRICAL: $ � OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Coun Assessors Office at 970-328-8640 or visit www.ea le-count .com
R��+�±�!#
2101U�s �210��
Job Name: U�•,(s �^t �r Job Address: �S� U�, � ���
Legai Description Lot: Block: Filing: � Subdivision:
Owners Name: Address: Phone:
v�.:
ArchitecbDesigner: �2�y� Address: Phone: �
Engineer: M��� �,��� Address: Phone: �
REASON FOR REVISIONS: 5.�,� ,��h„�� �G,-;-�-,�.a-he..s
Work Giass: New�Addition � } Rer�io�ei ( } Repdir( ) Damo( } Other( )
Work Type: Interior( ) Exterior( ) Both( } Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No, of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
, FOR OFFICE USE ONLY �
� �' i� �r �s � �
Other Fees , F .+Y �t3�c�a .a�n� Grou cce t d ����
'Fype`:of..C4nst�u�cfi�Qn :_;�..�. . �:;,�: '.pate.. ..��eEVed: ��� 1 � l
� 2��� � �
F:\cdev\FORMS1PermitslBuildinglbuilding_revision_11-23-2005.doc Page 1 of 2 � 12/8I200� .!J
� i
? �� �,��`o!� r
__.�.� ._ _ �
� �
builtl��.
�o������
Building 17epartment 5eivites
March 12, 2008
Charlie Davis Town of Vail
Chief Building Official, Town of Vail
75 South Frontage Road ����
Vail, CO 81657
RE: PROJECT: Vail's Front Door
PERMIT NUMBER�&48' g��g—OOI�
REVISION NUMBER: 15
INTERNAL REF#: 6133
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans: Sign Package
Plan review fee: $0.00
No additional square footage- No added valuation
� �
Sincerely, ' _--
Shane Gremmer
Plans Examiner
SAFEbuilt Colorado
shane.gremmer(a�SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓\\Eaglel\eagle shared drive�Plan Review�Final Approval
Template_FAL.doc
�
CC—�
�1VPICAL CONDITION
vSCFLE:1l2'=1'-0"
Background Color P-OS
Match PMS 411
Symbol Color:White
Background Color P-Ol
Black
Text Color P-06
Match PMS 468
y��
ASIgnTypeab.1657AIRID10UT51DE57AIR) NOTES:1/4"thickplaquewithADAmmpliant,
scnie.rarcsae raised text and braille.Plaque face will be photo
polymer on an avylic substrate(.1875"thick).
Secured Flush to wall surface with VHB-VT or
silicone adhesive.
Locations for the back of house signs will be shown on the location plans for
their respective buildings within the project.
ro�CO`80303
DESIGN INTENT DOCUMENT
V A I L R E 5 O R T 5��
Vail's Front Door
Vail Fesons Development Co
Kv
GENERALNOTES:
� repSWkpsh��uantin�5ubmmais
sectioultli�isdaummt.
� tl�avAn�asviswtleslgM�eronNFinal
engineennq�aterlalgndab.�<atiafiallremalnne
�eayuri�IGllfqlihtlabrkaio�
� rolWhtlaumentsubjecto[hMn�gn
ntrequlremenmuNinedelsewfie�eln�e
EocumenWefer ta the Fab�ICamPMOrmanc6
MaterialPequlremen�uaneitles&Submirta�s.
Matenalf FinisM1esa�dfom�Symbolzxtions
ol�M1ivl�i�mMpiliiiil�Me�all..
OPIGINAL ISSUE�. 03 AU jll5i,2007
�
I
I
OVERALL SITE
BACK OF HOUSE SIGNS
�o�r,r��,�a�,o�A,
t�3P riStree� Bou c�aCO`80303
*E� .aa .ei0l r. . O.IUV6
DESIGN INTENT DOCUMENT
V A 1 L R E S O R T S"
Vail's Front Door
PPOIECf
Vail Resorts Development Co
OWNfF
KP
IERM lOBNO-
GENERALNOTES:
� re�+d:W+nm�a�r��sucmnais
urnnmhhiH�rumant.
� drawinF}m�srisurtlesigmteron�yFinai
engineeiinq�ateriaiandabricatiahallremaiMie
esponsibiliqflM14aWl<a�o�.
� on erofXtlhdocumeM1t sub�xroNMesgn
�rea�o-emP�m�ar�PnPiv.wna,�m m�
doc en0iefe�toMeFabrl<atoPe�forman<d
Mate alNequi�rtwntq}uan itie.cW 4iMnihal�.
Ma�erlal6 Finisiresd�tlian��Sympolsettions
onn�m��meron�nnede�axs.
�uic,ir�n�issUt: 03 August,2007
FENLONS'
20 July,2007
VAIL MOUNTAIN CLUB
BUILDING ADDRESS SIGN
�. - `
1 �{_� -
J �_
� ����
!� � "� ��
7�
_ — � _ , I�_
��.
� ,i'�-l�_rz,~
_ u � �_ u
J {_ _
i� � ,
� ���
i
,
,
4 } '� .
------ J �_ � �;
�r- ��- i.
— --
V� \A7Ll�ktYj�tn3�"�I�4'il�!: ' -
� '� � ���
I � -j� L i'` �'
7 �
—� � ��`�U`" :
� , _.�._ .�-_ .!" .
., - . . . .� .. �. . .!,`
�
A Building West Flevation
SULE�.t/<=i 0
t s
° �; ,. �� a ;..--
�/�
o�
�,
����-
���-
��-1`1%�
" - � i<�>
..� _�" � y- * .� �
_� 'i.. � i�,._ s�, W �:`� � �`�,
��_�.
��.._. !_ �' %;.
2n
�
e . � � �`
, � ' ��
.- --,� ���•
�r, �' � '"
k
0 `
� " � F7
�� � � `�. ,:...sr
�� � -�,� ,<
— ��I�
��
� ` � �
�
� �
;;
�� ;
� •,/�,��7�: '�►' �.�.�
�At
�•"r� . µ�� �
Photo references of Luminore coatiny applied to acrylic.
VMC Badge:Cast bronze
Pin mounted to stone face of building
Alternate option:acrylic or resin badge
with cold spray metal coating(Luminore)
with uniform light bronze finish.
VMC Letters:Presicion cut brushed bronze-Pin
mounted to stone face of building
�Sign Type 4a.1:Building ID A Sign Type 4a.L End View
XALE:�'=1'0 XAIE:I"=I 0
Total Sign Area:14 sf
QTY:1
m s ``o �oq
;::.°emma:�,.e,�a..�om ,o a
DESIGN INTENT DOCUMENI
V A�I�L^oR ETS O R Tp5"
Vail's front Door
Vail Resorts Development Co
OWNFP
KP
hnm ioeNO.
GENERALNOTES:
� et¢iiWryhheQuant���5ubm'aals
uc[iaaf�M1'tl¢wnmt.
• Jiawn��Yg.n��vsuatlesgM1nienanyF'ivl
engineenng�a�enalqndfabricatlwhaikemairMe
re:po�:�anqnnaacn�aw�.
• cun erqiMhJu.umene wb�x�o�hetlesigi�
' reQUlrementvullinetleluwherein Ihe
EocumenHeter ro the 4abricaroVerformanc6
MaterialPCqulrement!4wntities6 Subminals,
Ma�e��sia r����,ne�a�aFOm�,svmeoi�cno�s
onn�,d«�merorn�rm�cau:.
oaiewaussue� 03August,2007
PEVISIIXiS:
oae32 June,2007
20 July.2007
VAIL MOUNTAIN CLUB
ENTRY IDENTIRCATION SIGNS
I �—
i� —_^
_
�xa�E:;_�.a.
Total Sign Area:.5 sf
QTY:5
NOTES:Machine cut vinyl applied to the second swface of
the enhy door glass.
_ .__
A Building West Elevatlon
scn�e�.vz=i o
�-
� \
/ \
— %
' ^�r�_ �
� ✓
A SignType4a.15:BUildingAccessibleEntranceSign
scniE:3�=i�-o^
NOTES:Machine cut vinyl applied m the second surface of
the entry door glass MOUNTED AT 60"HEIGHT CENTERL W E OF SIGN
�
�°s�,� , �_� °�a'ao�o�
r��JO]aaa. r. .oa0.�096
DESIGN INTENT DOCUMENT
V A I L R E S O R T S�
VaiIS Front Door
PNOhR
Vail Resorts Development Co
KP
GENERAL NOTES:
• �epViletipd[�a0uanti�0 Subminals
�n�o�nn�,e«�me�c
� r win�YpaxvhuatleslqM mntyFinal
enginming�atnia�pndabricatimhalbemainFe
i,��dn�uMmn.,e,��.,�M.
• nerofMMtl«umentsubjectoMedesign
r n 'netlelsewFereln t e
EocummqNe��o tM1e FabrkatoPeRO�manc6
MaterlalNequirementqluantltlesB Submirtals,
acia �ni�M1ewntll�nt�SymWla.rii�i�s
onn�,e«�mebn�nnm.�,n,.
nuaHn�isx���. 03 August,2007
FfVI5bN5�.
VAIL MOUNTAIN CLUB
ENTRV IDENTIFICATION SIGNS
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING 'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . : OS/12/2008
Legal Description: -��; �j 4�- oo� � Expires . .: 06/17/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone : 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533, 311 . 70
Totals . . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet 0
+************r**r******rs*a**a*�x��+*+*+�*************************r* FEE SUMMARY w*******►**s******+*r****r**ra+*r:�***e+s�*��**►*►***►�**►***
Building------> 10 3,2 0 6.1 o Restuarant Plan Review--> $0.0 o Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 103,206.10 Recreation Fee--------------> $0.00 Additional Fees-----------> $904.97
[nvestigation-> $0.0 o TOTAL FEES-------------> 2 0 6,415.2 0 Total Permit Fee----------> 2 0 7,3 2 0.17
Wiil Cali-----> $3.0 0 Payments-------------------> 2 0 7,3 2 0.17
BALANCE DUE---------> $0.00
.***a**#�*es+�a****ar*********+****srsr*****:r*►***�*�*�*e+�s****s****�*r***s**�*�**r*rs�s*�+*******++****�****�:r*�*t«s*s+*z�a*s*++�s**+*e*+�*�*r
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granteci tor Grading, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit.
required prior to issuance of partial permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA 5taging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs .
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Additional Permit Fee: 148 .48, Plan Review: 96 .51. CIA % per contract Permit tee:
Plan Review: 77 .21. Total tee ot 244 . 99 must be collected prior to release ot rev:
03/Ol/2007 MROYER Action: DN Revision 5- Dock levelers . Comment letter f
Doug Thompson and Neha 03/O1/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelE
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No aaaea
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Revl4, IR6037, Temporary Restrooms approvec
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval tor Shoring System Final ]
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck claritications ap�
issued. no additional fees.
Ol/17/2008 mroyer Action: AP Approval tor Rev #7 3090 Elevation and Slo�
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No ChargE
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#6133
03/24/2008 nchand Action: AP Approval tor ASI-5041 IR#6556 B06-0018 REV
EXTERIOR HEATERS
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections by ]
Engineers have been received and are ok. See SAFEBuilt letter in tile dated 2-5-0;
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor exc
shoring and grading only. Addtional approvals required for building permit .
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the constru�
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi;
03/05/2007 George Action: PA Building A. This is a partial approval tor
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI 5-038 TEMPORARY TOILET TRAILER PLAN N/�
02/19/2008 GR Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No Chargf
03/31/2008 George Action: PA This is a partial approval tor a revision t
club patio area to add outdoor seating, changes in stair design and a moditicatio�
swinging gates.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
02/14/2008 McGee Action: COND Provide detailed plans tor gas shut ott to:
heaters .
Provide detailed plans and new mechanical plan for fire pit .
Provide review by BCER tor tire exiting due to changes in sidewalks per original ?
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant.
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rf
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane=No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot DocJ
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
*�.:***..*�*....****.**:.+.*.*.*,*,:*��...+*:*s*�*+**.*.**.****�.**+.�+�**�»***.**.+..*:***.�*s*..******.+....*��*«+«.+..*.*....*:�****,**�*�*.*�
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. �
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
�%�.�r,�. 'i?�,,�- ��_
SIGNATURE OF OWNER OR C CTOR FOR HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of OS-12-2008 Status: ISSUED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: OS/12/2008
303-825-1313 To Expire: 06/17/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
*****+*+++*+****************************+++++++++***************************++****+*+*+++++*
TOWN OF VAIL, COLORADO Statement
***************+**+++***********************************+++++*****+*************************
Statement Number: R080000668 Amount: $180.00 05/12/200803:47 PM
Payment Method: Check Init: DDG
Notation: Hyder 59749
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207,320. 17
This Payment: $180.00 Total ALL Pmts: 207, 320.17
Balance: $0.00
*********++*********************************************************+*******+++*+***********
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 180.00
-----------------------------------------------------------------------------
�.h ,�
���-� � bu�i����.
�_.�����a��
Buitding Depariment Senrices
March 20, 2008
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: ASI-SO41
PERMIT NUMBER: B06-0018
REVISION NUMBER: 18
INTERNAL REF#: 6556
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2006
International Building Code as adopted by the State of Colorado. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Site plan, manufacture specifications
Plan Review Fee: 60.00
No added square footage
Sincerely,
John Plano
Plans Examiner/Senior Inspector
SAFEbuilt Colorado
Eagle, CO 81631
Office: (970) 328-1790
Fax: (970) 328-1791
John.Plano(a�safebuilt.com
Page 1 of 1
SAFEbuilt Colorado Denver West Office✓3000 Youngfield Suite 167✓Lakewood,CO 80215
Phone:(303)462-1955 ✓Toll Free: (877)462-1955 ✓Fax: (303)462-1965✓Plan Review
�..° �
� � ��,.,j d�,� ) ` �� ,� � f����� �,�� �
�.�
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE�(���� �
Building Permrt# �{�"
. 9�70�-d79 2�149{Inspect�o�is) .
�..�>� �:,
� ,.n ._
������ � � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be performed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. N .: Contact and Phone#'s:
�L ��e,� _ � UG-�-- �- 3�3- fa�- �i��
ATTENTION: JOE,JR,�CHARLI GREG,CHRIS
Contractor Signature_� _
- -- --
�.__ _-_
; � �
COMPLETE REVIS ONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ,�% ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contacf Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
P�rc�i�#
� l� l �; �Z2 ( �� �
Job Name: ���,� � S G--y��_� I�� Job Address: �� �,;'�,��f � ��
Legal Description Lot: Block: Filing: � Subdivision:
Owners Name: ` .Z� L, Address: . Phone:
ArchitecUDesigner: �����; Address Phone:
Engineer: �, n�,�e ��,-���� Address: Phone:
REASON FOR REVISIONS: �,t���� ���v� ��, � , , �
� �z 5--�- �� ;
Work Class: New Additi�n ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family ( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
DoeS a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
***************************�*********************FOR OFFICE USE ONLY**********************�*�*********************
Date Re�eived:� �: .Permit Fee 10 :.. �:. ° ��� �Plan Gk Fee'80 :.�. a;:,�
Accepte�i By :�,. � �� ; Permit Fee��,(11): � � �� �� �PIan�Gk Fee,;�81): ' �; �
Outsourced Terms: '
� .��. �. . . � :
F:\cdev\FORMS\Permits\Building�building_revision_4-18-2007.doc Page 1 of 1 4/18/2007
f
��c�����' H der Construction
Y
April 4, 2008
Revisions ready for pick up. Doug Thompson has been contacted. These are the fees
due:
Fee
Item#
B06-0018 Revision 14, ASI S-038, Temp. Restrooms $120.00 81
Revision 18, ASI_SO41, exterior heaters $ 60.00 81
TOTAL fEES DUE TODAY $180.00
f
�������� Hyder Construction
April 4, 2008
Revisions ready for pick up. Doug Thompson has been contacted. These are the fees
due:
Fee
Item#
B06-0018 Revision 14, ASI S-038, Temp. Restrooms $120.00 81
Revision 18, ASI SO41, exterior heaters $ 60.00 81
TOTAL FEES DUE TODAY $180.00
�
. �
�� � � �����inc.
�c��c�€��c�o
Building Department Serviccs �
4
November 26, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Front Door-ASI S-038, Temp. Restrooms
PERMIT NUMBER: 606-0018
REVISION NUMBER: 14
INTERNAL REF #: 6037
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Site plans and cut sheets for temporary restrooms
Plan review fee: $120.00
No additional square footage- No added valuation
Sincerely,
��
Matthew Royer
Building Official
SAFEbuilt Colorado
P.O. Box 1618
Eagle, CO 81631-1618
(970)328-1790
(877)428-6412
matt.royer(�a,SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓F�:(970)328-1791✓V:�Plan Review\Vail�Front Door�B06-0018\tov-b06-
0018.Rev14_FAL.doc
�
� u
�
APPLICATION WILL NOT BE ACCEPTED IF I MPLETE OR UNSIGNED `�S�-����(P
�.1 Buildin Permit#: �, o�,}�►`1
�� �V ` �'�������'���X ' ��a,��1 ��"-
. �" _
�'��'�� � REVISION TO TOWN OF VAIL BUfLDING I�1� � � � � ~l�
Separate Permits are required for electrical, plumbing, anical, etc.!
75 S. Frontage Rd. �"��r�y�;t �� ��g�
Vail, Colorado 81657
***All Revision submittals must incl F�. I �`;�e d plan . o further inspectio
e n °t��l t�li��=eWi�io � e rove **i`T"OW N O F VA I L a
w�ll be reform ��
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
� — - 5G/ � d�'i
A'i'T NTION: OE JR,CHARLIE,GREG,CHRIS
Contractor Signatu • -�
`��--
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ , ELECTRICAL: $ --� OTHER: $
PLUMBING: $ MECHANICAL: $ � REVISED TOTAL: $
For Parcel# Contact Ea le Coun Assessors Office af 9T0-328-8640 or visit www.ea fe-count .co
��. ,,�� � ���_�
�-�'ti� a
-q���
�
�,/��'«�
Job Name: 5 w � Job Address: 1�/ �l�.�f,•� e .;'�
,-
Legal Description Lot: Block: Filing: T��,�����4'����'�j� ; , r
Owners Name: C' Address �F�j'�. t�,,.a`� ����y�a��' Phone• � ,�j
Architect/Designer. Address: ` hone� �
Engineer: n� � Address: Ph��
REASON FOR REVISIC3NS: `
� _ o�� ���� Tz��-� r��-�� p �.
Work Class: New( ) Addition ( ) Remodel ( ) Repair( ) ��mo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accomrnodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin N07 ALL�WED
Does a Fire Afarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
********************************* *FOR OFFICE USE ONLY'k**�`**�*�,���„���`�'�`�*�"'`�`
�,�� � � r W, �°"�^ i :.. . , :_�rtx�xt o :i < , �w'4 s ° � L� ��$ x �t
..Da�tet � � �r � � j�� �ta.,��,� ; ��£� , P�rm�t�fe�' '�D . ; , P�� .a e �� .�
,
� � .� _
.AGCept�d��r�� r{ t:;�}ry. .� , °�'�;;,� Perm�t�ee,��1�M�� � ,r, ,: Iar��G�C F�ek�B� .',,� � ', �
Outsoirrced':Terms:`,� � 1 }'�� �`
F:\cdevlFORMS\Permits\Buildinglbuilding_revision_4-18-2007.doc Page 1 of 1 4/18/2007
TOWN OF VAIL DEPARTMENT OF COMMLJNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VAII, Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued. . : 06/26/2008
Legal Description: � �� --pp;�� Expires . .: 06/17/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115. 18 108, 815$12, 533, 311.70
Totals. . . 108, 815$27, 739, 000.00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #oF Gas Logs: 0 #of Wood Pellet: 0
*****r****a*a**a*a**ss*s********r*****�****►**a�s*x**�*t************ FEE SUMMARY **********r*a**�***s*x***********�*�*x*x*a*s*ss*rs**s*r*s*�s
Building------> 10 3,2 0 6.10 Restuarant Plan Review--> $0.0 0 Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 10 3,2 0 6.10 Recreation Fee-------------> S 0.0 0 Additional Fees-----------> $1,0 2 4.9 7
Investigation-> $0.0 0 TOTAL FEES------------> 2 0 6,415.2 0 Total Permit Fee---------> 2 07,4 4 0.17
Will Call-----> $3.0 0 Payments-------------------> 2 07,4 4 0.17
BALANCE DUE---------> $0.0 0
ss****ss:****+s***►****a***:s**s*:*s*ss**s***s***a*s*a***s**s*s*s**s+s**+*s*s*�**:*s**s*****s***s********s******�***x*:**:*************a�******a*
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading, Excavation
Shoring only. Other approvals required prior to approval of full building permit.
approval
required prior to issuance of partial permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ONL
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions and
department sign-offs.
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural chan
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
$60 . 00
02/07/2007 MROYER Action: AP Approval for temp. stairs on East end of Lo
Tower.
Additional Permit Fee: 148 . 48, Plan Review: 96. 51. CIA % per contract Permit fee:
and
Plan Review: 77 .21 . Total fee of 244 . 99 must be collected prior to release of revi
03/Ol/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter e
to
Doug Thompson and Neha 03/Ol/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levele
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clarificati
comment
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. l1, IR 4225-Grade modification/ accessi
no
additional square footage. Plan review fee $300.00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No added
valuation.
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Rev14, IR6037, Te�nporary Restrooms approved
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval for Shoring System Final R
and
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck clarifications app
be
issued. no additional fees.
Ol/17/2008 mroyer Action: AP Approval for Rev #7 3090 Elevation and Slop
Elevation
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter from Koechlien on Spe
Inspection and Letter from PCL on adjacent building monitoring approved. No Charge
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#6133
03/24/2008 nchand Action: AP Approval for ASI-5041 IR#6556 B06-0018 REV.
EXTERIOR HEATERS
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections by K
Engineers have been received and are ok. See SAFEBuilt letter in file dated 2-5-08
lcampbell
05/20/2008 NSC Action: AP Approved B06-0018 ASI-028 REV.20 IR#7562 -
of
plan review due, $120.00
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for exc
shoring and grading only. Addtional approvals required for building permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ONL
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval for the construc
a
temporary stair to provide emergency egress out of Lodge Tower South. This stair i
temporary
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is for the addition of loadin
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval for
clarifications to the stell decking only. No other revisions are permitted by this
approval.
03/05/2007 George Action: PA Building A. This is a partial approval for
in
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI 5-038 TEMPORARY TOILET TRAILER PLAN N/A
02/19/2008 GR Action: AP Rev. l7/IR6346, Letter from Koechlien on Spe
Inspection and Letter from PCL on adjacent building monitoring approved. No Charge
03/31/2008 George Action: PA This is a partial approval for a revision t
ski
club patio area to add outdoor seating, changes in stair design and a modification
swinging gates.
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and excavation
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ONL
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
02/14/2008 McGee Action: COND Provide detailed plans for gas shut off for
portable
heaters.
Provide detailed plans and new mechanical plan for fire pit.
Provide review by BCER for fire exiting due to changes in sidewalks per original p
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant.
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
06/23/2008 mvaughan Action: AP asi s-042 for retaining walls
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated re
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 for installation of Dock
Levelers.
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
Item: 05550 ENGINEERING CIVILS
»*:*s*�,.:,:,:�.*«.*****+::::�*******.**.*::*,.:�*�******s*s.***�*�*:*****«*.*s**+*:**:*:*****:*::.*:**********«*s****+**:******�*****:*******«*s
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved,International Building and Residential Codes and other ordinances of the Town applicable thereto.
�_
REQUESTS FOR INSPECTION SIIALL BE MADE TWENTY-FOUR VANCE BY TELEPHONE AT 479-214 T OUR OFFICE FROM 8:00 AM-4 PM.
SIGNATU OWNE C CTOR FO IMSELF AND OWNER
----._-
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 06-26-2008 Status: ISSUED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HI'DER CONSTRUCTION, INC Issued: 06/26/2008
303-825-1313 To Expire: 06/17/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUII,DING'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R080001034 Amount: $120.00 06/26/200810:20 AM
Payment Method: Check Init: SAB
Notation: 60207-HYDER
CONSTRUCTION
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207, 440.17
This Payment: $120.00 Total ALL Pmts: 207, 440.17
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST L"
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 120.00
-----------------------------------------------------------------------------
,
����� � Hyder Construction
June 11th, 2008
Permits/revisions ready for pick up. Doug Thompson has been contacted. These are
the fees due:
Fee
Item#
B06-0022 Revision 15, ASI E-077 $ 60.00 81
B06-0018 Revision 20, ASI 0-028 $ 120.00 81
B06-0028 Revision 8, ASI E-056A $ 120.00 81
B06-0021 Revision N/A, Ref#7436 $ 120.00 81
TC�7A� �`E���'l�E��3i�AY . ' , ,�...
��
,,.,� ,,, , .� , _�. ",., � -�.,� . ., „ . �x �����,. . �'���j",,r�'a�`���
�
buil#�n�.
Ct�L(3Ft�C�[�
Bnitding Department 5ervices
May 20, 2008
George Ruther
Community Development Director, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: F or
PERMIT NUMBER: {��`
REVISION NUMBER: 20
INTERNAL REF#: 7562
ADDRESS: 151 Vail Ln.
Dear Mr. Davis:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Description: 7- Sheets of Structural drawings
;���� �; r�
'No additional square foofage- No added valuation
��.
Sincer �
�-
John Plano John King
Plans Examiner Building Official
SAFEbuilt Colorado SAFEbuilt Colorado
john.plano(a�SAFEbuilt.com john.kin�(a�SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colarado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓V:�Plan Review\Vail�'ront Door�B06-0018�B06-
0018REV 20IR#7562_FAL.doc
- o �
APPLICATION WI L NOT E A CE D IF INCOMPLETE OR U IGNED
Building Perm�t#. � .,)�(o �.C�� �C''
i, �7������2����nsp ctit�ns�) �
������� � � REVISION TO TOWN OF VAIL BUILDING PERMIT ��� ������
Separate Permits are required for electrical, plumbing, mechanical, etc .
75 S. Frontage Rd. � �C(�`�� k
Vail, Colorado 81657 �
***All Revision submittals must include the Field Set of approved plans. No further inspec �ons �e�/�
will be performed until the revisions are approved. *** �
� /��,
CONTRACTOR INFORMATION � � � v
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
� v� '�� �0� — �4 303_5� - �'l og
ATTENTION: J _,JR,CHARLIE,GREG,CHRIS
Contractor Signature: �/�1
t�
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel��
2tv► o �� 210��-
Job Name: v�•( I ' �j �.�-Vd,�-� p��- Job Address: � �"` �� l
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: U a Address: . Phone:
Architect/Designer: y,� y,� Address Phone:
Engineer: ����u� � ���� � Address: Phone:
REASON FOR REVISIONS:
Work Class: New Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
*,�****��******************************,�**********FOR OFFICE USE ONLY**�*****************************�**�******�***
Date Recei�ed:�: ' . . , .: ; Perniit Fee�' 10 : . '= � ', " �-��`:;..� _ �Plan G�C Fee'80 :-.� '.° � � �;
Ac,cep"ted By:,����� , �� '� �Permit Fee�{11): �. � � �PIamC�C Fee�81): '� � �
Outsourced Terms: F ��w''
F:\cdev\FORMS\Permits\Building�building_revision_4-18-2007.doc Page 1 of 1 4/18/2007
� . •
� - r
� o d
0
4 �-
ARCH ITECT'S SUPPLEM ENTAL V,4��'s FrtOtv� DoOR
INSTRUCTION No. A- 028
To Doug Thompson / Hyder-Canstructian, Inc. PROJECT NO: 20693_OH
543 Santa Fe Drive � J issuEO: p4.28.08
Denver, CO 80204 �� � � FRO� Neha Khera
^� �
303-825-1313 � /� 303-292-338$
The Work shaIl be can-ied out in accordance witt� t}�e following Supplement�l InstructioF�s issued in accordance�vith tl�e ContracE
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accorciarlce with these Insti-��ctions
indicates your ackno�vledgement that there will be no change in die Contract Suin or Contract Tune.
Architect's Supplemental Inshliction Title: Building A—Opening A210C�Resolution
Reasan foi-Clia��ge:
At the reyuest of VRDC,a solution has been developed to resolve the 18"step at opening�lOC.
.�v�i�`a� `y ��
Description of lnstructions: SUbjeCt t0 InspeCtiefl and Compliance to all
i-:!evant Adopted Buildin and Municipal Codes.
See attached. �hanges in Plans U e proved. T�WM1 O�f `V11�
a�te 5-2�-08 By ���
�.,d�, z�� — � FF� . .� �� y
�___ � �
`���F=F.built Colorado
Attach�3ients and Enclosures: �,
Alpiiie Engiueering SheeC: As built tunnel slab and cei��ng l�eights redesign,dated 04.15.08.
1VIom-oe&Newell Sketches: SSK A-105, SSK A-106, SSK A-109, SSK A-110, SSK A-111,and SSK A-112,�Il dated 04.28.08.
'_;x
Copy To: ASI File
By� __ Rar;dy Hart/4240
Neha Khera/4240
Submit to Town of Vaii: � YES ❑ NO Rick Caudel/VRDC
S.Jarvie Worcester/VRDC
Gleru�Palzlaer J Alpine E��giueering
Iim Ness/Monroe&NeweIl
D � � �� � M ��
�� �"�t�'�k�;; �•�F•..— �
42�40 ARCHITECTURE INC ' ' ,'
.._. --._,
1621 Eighteenth Sn eec
Suite 200
Denver,Colorado 80Z02 The informalion con[ained in ihis message is privileged and confidential inlended anly for the use of lhe individual(s)or entity{ies)named
c 303.292.3388 f 303192.31 13 above. Ii the reader of Ihis message is not Ihe inlended recipient,you are hereby notified tha�any dissemfna5on,dSstribulion,or copying ot
www.924Qarchitecture.com this communica6on is strictly prohi6ited. If you have received lhis oommunica�ion in error,please notify 42l-00 ArchitecWre,Inc.immedfately.
�`F� !�, �r"`�,,».
�6V 1SC—� - i- " � ,c'`�s ��_.�OP,��.
D169'-5' �'}' '�• �'t'.�
'T12�GH I ; �',J� � ��/�' '�n,
D�+� oN�j� ; ���` j j; % �;';' Ft�'"��.
LOGR77 . f!;-'i' ' ," /i ,a's°e
e�oT-�s�.�- F �. j ��/i / 1 • ;
� '` i � � ' � �� 1
�- ` �, � _
�z � aive=r i �..
` \` � \\��. ` ... i / / r � 1 '
\ _ ` `�, �� i �.,�y �
a. • �. - --U- L- /� ,� °+ t^ ' ( i t°�F 1
�/ �:j � �---+�� / ` �' y .'n �'s �
.,\�`�O'i%• ` ` ` / �+. .. '
� j � r � � �
�\ .,,.��� � i �BIl�6�$�'g �, ' � ;r ,-;
, ,;
:,: �..� 8•TM�k� - —
�• � �,�� \�, c F �i �---
'� � •���..� 9.
� � �'"�•.,- ,fi� \� � •�'' ,��' Z� �
'� •%" � ;��' ��}' °��' '�p\. ��' •,� ----- --------------- ° ----- ' "
� s�-� i p�.� � -
" 0
`� ` \�\��. ��'' o
,' �. . ,'`, � CA
/ / - �
O , . \��.+�"�'_'�..�' '�.. ��� _"����"��"' ' _
� .� , ; .\ �'�"�
_ ....1.`\� '_' '� � � '� • / � �
i
':"/ '��/ "d�ry 'r ' !�, `V��,� i H161'-O� 616T-O
/ . ^ f
.� i 'b i � � pQa1�� i� C Ar ~� '' p I
. 9 �,� �n�I '��� �'/ '' r ��I
J':
O `A \�\ /� /�' I ��/ �' gt p��',b9'�
- Q• `��..'' -'' '" '� p ' 1
.� � ;� . . .- � �',,�
r
�p�•.��z � •�\� '���'�,r� '�i� �\` �+09 ��I�
u.�• �_ I -�-�! ';�,- °�- -
Q.5 ----- \°-----'• �=c----,. �—i----�
�; � � � '� � �
�'�
. � �i '�� \ �� i �� I .ilp'
��� � X�' �'��' � r f ' \`,' �b� D I
Q \ o` 9:y� �� � �I �� � � ��` t b =�i
n dba �� �� i� �� � �b '�,�Ys
n \
a � � � � � �� � ; �
- ��,�i� �� � �i• �� ,�N o�aa•- �n_-
� �.�i .\'�� /��i�' i� \s�� �'' ���
s�;:? _� � � --- -----
E7 _—_._'__—__Q. 9pe—'_�. .��` � ��f_'—'� �i ' ,��. b?n__'`�Iti"_
�` \� iv i ." n�� �, �1�
i i e�., D� C��.
5�lADED AL'�F} �q � ��.-'��� .� ,- �.� . � `' ;.
' �`�, �
/ND1 ��� � o• p+r� \\!i ', ���i� I i� '
�Q�S �a o� 9-,`f� I .. ' � �i i`Oh � i
i I
Tiflck To P�N✓G o ��` \\ . .�' �i ry`� �°rq ! r � ,4 `.f+ 8166'-T
� s�. P-�-'Gtv�� °• z �;I�.-'"..- � ��.,,.- .�' , ` �,�� ,,,� ,/�— .�
m �/�4V/NL� FoIQ E�V.\ 3 0`�1 ��'� �� �i ��°.' .. °�" } -
0� �/4 O�'=�dPI�I . \ �o��,}.o.(� � i �'i' `�� � '�� ° aws•�7�/�• n
ry �� �QO - � �Y�' � � �/ I h51 A�015
vi.a�es �t �\ 43 ��� �� \�\ �� ii',0 o•-q�� '
.,` \� i 3�'i \V V ^ D� �i XO
B'CCH:.RE�E SNS F7�N�5 I / 1 � / _ i�Y '
TGP/.F87 BOTTOI'1 Fi 1'-0'. �17"�� �'I � I � R
PERPE�ILUL/�RT09EAH. \ y1� ��� �� �� C I('� �� �� •• o � Y<� � 8166'-AI!"
`>.
J TOP i.tm B�CPI ht 1'-O". µr' \ `+� ^ � /� I ,:`�1 '
PA2+U�l TO�N o �:.� - � � �.��� / � '�'� lt
rzE� _v-snou�530� Opb9 �\ ��a \�\ ,i �� ,H r; � ��
1—� ' / �[` , i � � _ !iti 17
�`� ____�'_'—'_'__'_�" \ /J'L !�_ '! �.._._ '� • O -� 'm —' '_
—' \/ ` \� F' ��� 0Ab p � � m
! / � p /
�S. �� �i �� �r:` `` n
\G. /�. ,.\\. �i '� �/., i� i� •,�t4'�� i et'T+Lo
IeE-G�V��- DR4+WS, - J ..-��� � � ����� °0ob�-' � ,` �":;F
Fce Cu�2B ,q-n►D 6 :" �`�fl:���'�. ��a.���. � ��p ��� �\.
p � � �. . ����;��
,� L�'�'tu �,,Jvql.t L�{youT a.n� , �� ��� ; �•,, �•' Ao,�� ���''-
ci � 17�0�'` J11�• tiP `✓.' �iA d'°y9:z �� ��' J�O�'/ ��' •.
p�3��� d0p9,y:P iis5�w-o�5 O�i� �i '�� `'�� ��'�p1p �i
�u . � J 0p'1'n�..
I .� t16�,�.16 � �� �� +.9 'i��� b�p- .,,. '.
��E�7-t � L P C.��l i = '-' '"� °�p�:° - - i � ,"- '"-:;:
. .
,� p��_ /�i g �'�' a '� �
- ... _
L_5 '---- -- ------- -- ----- � -- � �-----
�-�L(NN�"L=�"_�r�7D � ' °' -
N �
.' �' o°
C � i� .' ♦
� n�-a�v� � �:,�i �� ��� `�'�'
� i, �i, :�
c �^ Z _ _�_ `?''`' . . P
, ''; � `b ' _
L - ------- --1-- ' -----�o----- n -i. "i
—�: SiaS'— __ 5 ���- ���--- � . _
, �- � �
��af�� �, y�S F�017.t �00r DP.AWI�IG N0: SSK— � �0�
� 0� B,ailding /�:
��/! � 4 ��/D��pQ REFEREPICE: S I OS
■ �ssu�: as�t RoZB
_, c.L�l.i I I fi. va1 Re54�5..�_.. :; DA7E: 4/ZS�ag
Dwsc�Colondo DeBelo ment Com azl SCALE: J �
P P Y DRAWM BY:�`j�
���,cdo�ao
�
, ,.
_
_. _ ....
,...
. : -
� �o�
,
_ .�7" 1 __ o C.� . :
. .
. . .
_ _ _: . ��f/ w�Y.
C2� ��-; �(n":
. . . ... :
__ .
_. � ..
.... �
' . . _ __
_ �_ _. _:.
;. ,
.
� ._ ;. , . , � ,�
_ . _ _
__ ,��.• �i�r r�.. a��?�.
__ � � .�_ .
� .
: �t��_ ����+� ,�------_. ;
,_
_ _
_ _
w 5���`� ��.�r,���Ec: � ��.
/ _ .. , . _
_
. _. _.
..
, �v
_ : _
_
: ..
5���'��y ��p �sre�� m ' �
..... � .�i �'Q. (�/1�....d!/.�f`f'G � ':' ' � . - .. ... . ..... .....
.___. ..:.. _........... . .. ......... .... ....... ..e--"""'""�._..l�r
. .. . ........ .... ...... � .
golt/l/;r�.�G; s�:6�/�T; ; ; ; , r '
__ ... ; ;.. .. _,.
< , ...
. ,
. ,.
° -
' ' .. � _' _. _
. .
.
. 4 .
._. � . �. i . . ..._. ....� . ..... . _._. .. .... . . . ..... ...
:. __. Il _.
.
:. ,. ..
,
; ; ! �+ /Jrr�'.X ;
; . '... _......._ ;r! ;�. .. _..
� _.. .
. _.. ..._ �: '
� ;..
...
r
_
: �
, _: .
. � _ _
_ : . ;
_
�trc�__ � . o�-- : : __.
.
____ , ._ �u.sr-r,+f� �c��
; ro✓ ,PC���. ; _; _: ; _ � ; ... ; .
_ .. .
C4 N C i�T� ' ' ` '
� . _
,.. _... ...
.......__. __. : .
,... .
:
S Z:;�t� ...�ZS ,.. ;
8�3'+`t_.. _.._. ;.
.
. .
=--�
. �__ _ _ . .._
. : . ;.
'
'`� �
,
�. �''''-�,
,.
.
.. .... . .........: .......... .......�-----�``.. ;.
> �.� ,9�/�
' ..G+; 0 a r�°d
. . ......_..... ... .......: 1 .
`
�
Y� . . ..N� . . ;t
. . . . ... ..�...' .
; , . . : : . . : ... . __ .__ .... . .....
. . . . . . , .....�.,� .. ....
.. .. . ,. i_.
............:..............:... . � . .i� � :
.. . ...._.... ... ..._... , . , � . . . . . ....
_...> . . . . .
���� : `�..
; ; °��.___.,_,_..�.--
. , .....:. -- :-i-._
<_. _... ...>. . .. .. �a;,f tir� c�_ �....
... .. _ �'�.....'�, �.�»`
,, `
.
, ; � 'k , t.. ; : rt�N �' ���'
........
� � .
:
�:
�' ��"`'�U .�. �° ° ° �. .
_ : _
. _ . ; � , . �� �-��'� ,
;
, .�— �
� a� d�, _
���� �.�a��ra _ _ _ ;_ �'"`r"""
:
_ _ k����
�,;�coe�� �Ta]IS B�O�A�� DP•AWIMG N0: �.S�SK— �Id�
���� ��'D� REFEP,EPJCE: �"
� �ssuE: Ass flvt8
Vail Resorts DATE. ���g�p$
�cot�� Develo me�nt Com an sr�E: --
P P Y DRAWhI BY:��^/
Avon,Colonda
�''�t►c�
co N4 �---f" �)�¢ �c coNT, G� (n�i
-�PP►�Ni StA� ! ,
1� �r � ���
� �t , p�, $�SX+��G°D r��L �v�
7 � 7 y �l�Cy¢�N7a �t�ST�NG GE�`�'"•rrl.
,•.. . - a+ -
. !J P « " , �a.:. �. . .
� �•
. . `' �d ' ; . �:.,; � .. .
6.`.. •p J.. a.
� � . ♦ �
. O , r � _ . - � _ .:if.._ . . . .
V����� � �'� - - -- ' -
t � �� � ' +.
Y/`,�'�I � a d . . .
� h� �
,
�/1 ,'
� j �/ : ._ , ' ._�.
q i
V. p �
� � � .. . ' � �,. a .
7 +. • _
. . . Y .�O . ' �� .4
A a # f
� .a.
+ • .. . �� ° •� a •
�
. ,�J '
�1G1� . � � ,
rNsc,rl.,4?lon1, a ' � ; � . ,..
TI��Gx/�ESf RE: BE�RM
� � � �.. 5G1-lEDUI_E
Vq�2��s °� --u-
. .
a � .
' •
m.� `�u1 O.� a 4
. 0 ..+. BI ' ♦ .
. e
SG!-fEDUL�
RE: BEAM
d� �� � �9 I �.!" 1 `L � �
���. _ �,_���
S3� j
:���:"�`�\
a •
REUIE�'�`�D BY ' � T�A���-°�,�
f es,
4 � � :(- ��
MAr �u �00� � �,�; �`� f�
e�,
f osnn�L��stlo,�f` :
����a:y �����s
SAFEbuilt Colorado � -�:�1�`
— ___._ �., r
�i,�cofit�o�a Y�S B����� DP,AN/1r1G N0: SSK"' �'IO9
,�„��p �-� REFEP,£1�lCE: 5 3� t
� Ovraez/DevcloPa ISSUE: �,= f�OTiE
,�� Vai3 Resorts QA�� •��Z�O$
benves,Colondo Develo ment Com SCALE:
P P�Y DRAWM 8Y: �/�
n�4 caomao
� �•
�Z11 '�ICK IS��-�tT70fV ��'N'7'r
CA2►I,_.K- Jo�N�r /-�-s �eEc�u�2�.
rr 8" GMU WITH �5
( Tf/lC� t'-0NG, � .6,T I,_4°
70�°/°�nlG S�
�i��� 1NSUtR_
TioN �#�c�c_
N � �I�{+2l�S,
� , � _ � ` . � . • . u,;, . .. .
b" �, _ � � a � - .
� A _ Q �� a' � � . .
._+� 'L.��� . . yII . . a� ' 4 r . •
��1 ♦ 4 .
�� e •
a.` ' � �
. . .....� .. . , . s . � o� . � . �e Q
° a q 6
d � � .•
' a � �. + 'Q ' d ' ` Q
c .,- ' e. � a/�(� �
. . 'a. t+ � Y �4
a ' •r ° 0�
° a „ Q
' f-
. • � ' N
� � �
v - r _ � �
a �
o .
0• �Q . °� • ° r
a' _ g�
° .4 . , RE: BEaM
% ' SGHEDULE
�N-I�LAG� ,��1
RE= BEaN�-% ,�va sc� ���
SGHE[7tJLE
-�""_.-.- """��e'�
t,1�����
�� �� �� 1 ��I. � 1 _ __ � °-°
�� `� S �AFa��
3l.�° _ �.,�„ � �
� �� � e �.
�. ,
� �. ��
L> �.,
MAY ��:i ZtlUB h `��-° :�,,,� L�r,������;:,:;�,�
� �.�� °�� ,. •����;�ry.y
� "�� � .�
�---- � `'=���'
' `�_"�...�.._�'�__"".�"_"__'-,.� 1'�.�._...�._-�
�,,;��of,� Vai].s Front Doo� o�,awiric No: �SK-- �4!/ D
4��ry Building A'
PEFERE�tCE: 5 3 o j
� OWnc/Devdoper �55UE: Q$= A OJ��
�� V31�RCSOILS DATE: �f�/p$
Denver,Coloada DeYelo ment Com an SCALE:� —
P P Y DRAV1ri BY: �l�1I
Asnn,Colonda
I
. , .►
;;-- 6 4 �/!c� c��c.
� a
e �aPP•��c� .
. � ��
�
�
, �
. � . : �'..._.....�..�.�..���.�...� `�
° : � - .._ _ . ,�
�
,
. _ �� � .
. . , - a. , -
; .;. ,. , . ,
0
. _ _
, _ , -
< .
_ � �
a ��� � � . :...�_.. -- . � �'�,
,_
. a. a
- ' G . • �•a. � � a � a .
_. . +, y� ' � .
a .�" . - ; :,: _ _
(2)-�4 GON7lPtU0U5 �°- a q . . _ �"♦ _ �
'` t° � " ° �`- �4T
' • - �a:-:_ . .
a' r �- �__---` —=`-
—ra ---.4r-.—'__—_:,-------�. . . . .
+J > a •' N
� , a� - I Lp � �; l�t�
� . - .... . �e ,. a a, . __
. 6 VA .� _ a . _ +. ., . . . Q
. a � a a , V�� �L�#t�7C
. • QI.. • ^t d � + . . _ .
,. _ n- . � . �o�vT, �.1.��
�_ _ : '
. � . ' �a . .� : /�'n/ c
a a�._... a + • . ' d ' , GUC?�J �'�
�2)-�'4 GOhiTINUDUS - ' � c
_ < __ � .���-��C.u�'!�
;._ _
� • '' LtNE OF 5L4B BEYOND
;o
- e:
. . . a ' ,� . �/►'"����
: ° 5U4B AND BEAM REIhIFORGINE�
°� Q . „ NOT Si-iOWN
. _ a .
. ,
. �
a 4 �N����
° � FOUNpATIOi+I WAI-L
: • RE_ PLAN
.a � .
9 . C . � , �-i-� '
• � � � . ,.... . � .. � . . .. �. F,. c .. Fd /;�
� F \• � � / ` ` �� '�,� `
a �
y �. y � .. . ✓�`1`
O
� - . . _ . . ' . . �!1
� .
.:.����� .... . . � ���• . ��:
p'.,�.
�� ��C 1 C�i�l i . __ �2�� �� :,
�--�,..�.- ,�,
3i.�- - �'_o' , =;'�',/
S3C�� - �.�-
„�;,�of,�, Vails F�ront Doo�
B��g r�� DP.AWING N0: �SSK— �-� �(
�,2,4,Q r� REFEP.ENCE: $3oZ
o.�/n��op� rssuE: Asr Pto Ls
�� v271 R.e50it5 DATE: 4�LS�dPJ
n��, Development Company D�zaWra Bv: �en�
Acvn,Co(oado
I
•1 � 1�
L�x�x s�$ x�oN,—.
WiT-H ls"� �6
f!.fl•S. �T /!p ��
p, C. �� S i�E S � � �C��
oPLn1►.vCq) 2c�<o
�Cl�'w (o `` CoNC. �''
��°P�n/G� .Sr��L
G►�TIN�
g y �7��2S
•d , . , � • 4 , , ,
�
• , , � � .
d � � • . d �
� - %, 2�IZ
�'��b��4 a/,/��
�,�-P�� L sx sx�8 �x
��,�EO �zxz CQ�vT,
,���115E Ex1�?%nfG �
/if/�.�°I�GE Co-�t/�Gti-°�'?'�'
��"r i il �Iy�.1 s�"�j
-ry P r cA L A-T C2) '
Lo�4`�0� rti t����.�� ,
�
cv�T �z,<v,v�'� S�C_?7d Y...� � E '5��9���,�
S�; f�-T �N�cH L e�� ��,
OP�iurn�C7� �13�a �...a�'�a: �c/ �
_ __.__._ � !
�
,�A� �:� Z(lOS � !; ''s'O..����G'���
I �' " ��c��`�� ` :
� �� - - �---- -__�� `
A:cLimccofltrco:d V�S F�011� DOO� DRAWIMG I�O: SSI�— �{112„
4�4o B,��g �
Owner/Dce[opa REFEP,EP�CE: 'j3p7_ o�
ISSUE: �'_ , �
�.� Vail Resorts DATE: 4./�/OG►
n�ow�� Decelopment Company SCALE: "�
Avoq Colondo DRAWM BY: d-J/v
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018 � -U4 Z x
1���c_
Job Address: 174 GORE CREEK DR VAIL Status . . . : APPROVED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . : 10/02/2008
Legal Description: Expires . .: 12/29/2008
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 108, 815$12, 533 , 311 .70
Totals. . . 108, 815$27, 739, 000 . 00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet 0
�*�+****�*+**+*�*****r+►��+*�***r*��*a**s�*s�****�►*�*e*»+*+r*****�a FEE S UMMARY *+*r*+��rr►*s++*�*s*���*►****+�***+**+*►+*�+*��*s+#+*r«�**r*
Building------> 103,206.10 Restuarant Plan Review--> $o.oo "fotal Calculated Fees---> 206,415.20
Plan Check---> 10 3,2 0 6.1 o Recreation Fee--------------> $o.o o Additional Fees-----------> $1,3 2 2.9�
Investigation-> $o.o o TOTAL FEES-------------> 2 0 6,415.2 0 Total Perm it Fee----------> 2 0�,�3 8.1�
W il I Cal 1-----> $3.0 0 Payments-------------------> z o�,5 6 0.i�
BALANCE DUE---------> $178.00
*t*****s*.�sr�****a*a:�r*****«*x***t*t*****************�*s**r*****�*►��****ast*ts*�***�**�**a***********►*xx*******r*t**�s**t*►a***ss�*�*a*+*a**e
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted tor Graciing, Excavatio�
Shoring only. Other approvals required prior to approval ot tull building permit .
approval
required prior to issuance of partial permit .
06/O1/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
06/05/2006 cdavis Action: PA Staging/Access Plan approved
07/11/2006 MROYER Action: AP Full building permit pending conditions anc
department sign-offs .
10/G2/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural cha�
Additional $0 .
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan review
$60 . 00
02/07/2007 MROYER Action: AP Approval tor temp. stairs on East end ot Lc
Tower.
Additional Permit Fee: 148 .48, Plan Review: 96 . 51. CIA o per contract Permit tee:
and
Plan Review: 77 .21 . Total tee ot 244 . 99 must be collected prior to release ot rev:
03/O1/2007 MROYER Action: DN Revision 5- Dock levelers. Comment letter E
to
Doug Thompson and Neha 03/O1/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock levelE
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clariticat:
comment
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade moditication/ access:
no
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No aaaea
valuation.
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Rev14, IR6037, Temporary Restrooms approvec
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval tor Shoring System Final ]
and
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck claritications ap�
be
issued. no additional fees .
O1/17/2008 mroyer Action: AP Approval tor Rev #7 3090 Elevation and Slo�
Elevation
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No Charg�
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#6133
03/24/2008 nchand Action: AP Approval tor ASI-5041 IR#6556 B06-0018 REV
EXTERIOR HEATERS
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections by l
Engineers have been received and are ok. See SAFEBuilt letter in tile dated 2-5-0,�
lcampbell
05/20/2008 NSC Action: AP Approved B06-0018 ASI-028 REV.20 IR#7562 -
of
plan review due, $120 . 00
08/25/2008 jplano Action: AP Temporary Exit plans dated by SB Aug.25, 20i
approved
$120 . 00 due
09/23/2008 jplano Action: AP Rev22, IR8825/This is a partial approval to:
addition of two lock pool gates and a change to two patio entry doors
(ASI B-056) - 2 hours of plan review due=$120 . 00
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval tor ex�
shoring and grading only. Addtional approvals required for building permit .
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ONJ
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval tor the constru�
a
temporary stair to provide emergency egress out ot Lodge Tower South. This stair :
temporary
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is tor the addition ot loadi�
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval tor
claritications to the stell decking only. No other revisions are permitted by thi;
approval.
03/05/2007 George Action: PA Building A. This is a partial approval tor
in
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI S-038 TEMPORARY TOILET TRAILER PLAN N/�
02/19/2008 GR Action: AP Rev. 17/IR6346, Letter trom Koechlien on SpE
Inspection and Letter trom PCL on adjacent building monitoring approved. No Chargf
03/31/2008 George Action: PA This is a partial approval tor a revision 1
ski
club patio area to add outdoor seating, changes in stair design and a moditicatio�
swinging gates .
09/02/2008 George Action: PA This is a partial approval tor the additio�
lock pool gates and a change to two patio entry doors
(ASI B-056)
09/03/2008 George Action: PA This is a partial approval for site work
modifications
to the parking garage "snorkel" wall . ASI 5-042
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval tor grading and excavatio�
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING ON]
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s .
02/14/2008 McGee Action: COND Provide detailed plans tor gas shut ott to:
portable
heaters .
Provide detailed plans and new mechanical plan for fire pit .
Provide review by BCER tor tire exiting due to changes in sidewalks per original �
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant .
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
06/23/2008 mvaughan Action: AP asi s-042 for retaining walls
OS/05/2008 McGee Action: PA ASI 5-041 Partial Approval : No data on tir�
appliance or shut off other than note to "comply with Building Code" .
10/O1/2008 mv Action: AP
10/Ol/2008 MVAUGHAN Action: AP Temporary exiting plans tor temp ottices o�
Item: 05500 PUBLIC WORKS
05/31/2006 ls Action: AP Excavating and staging plans approved
07/14/2006 tk Action: AP Approved Building permit revisions dated rE
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 tor installation ot Docl
Levelers .
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dated
received 8/8/07 .
06/30/2008 TK Action: CR ASI 5-042, Site moditications requires the
following
corrections :
l . The retaining walls behind the path gate and the Fire Hydrant at the
cul-de-sac are required to be no greater than 6 ' per Town Code, please revise.
Item: 05550 ENGINEERING CIVILS
.*,.*..�..*.....�****..+.+*+.+.�.+.+.+.*s*..**..s...****.*«*.....+..�*..*:*:.,*.*.*.*.*�+«+*�....�*.���*:..*«..s*�++�.s*.*s+:*s..+....*.+.+***�.+
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV E BY T LEPHONE AT 47 2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM.
SI URE OF O CONTRACT R HIMSELF AND OWNER
PAGE 2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 10-02-2008 Status: APPROVED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 10/02/2008
303-825-1313 To Expire: 12/29/2008
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING 'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
**+*+********�************+***********�******�*****�******+****************�**+*************
TOWN OF VAIL, COLORADO Statement
***************************+***�***********************************************+************
Statement Number: R080001826 Amount: $120.00 10/02/200804:48 PM
Payment Method: Check Init: LC
Notation: #60976/HYDER
CONSTRUCTION INC.
-----------------------------------------------------------------------------
Permit No: B06-0018 Type: NEW COMM BUILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207, 738.17
This Payment: $120. 00 Total ALL Pmts: 207, 560.17
Balance: $178.00
***********+**++**********************************************************+********+*******�
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 120.00
-----------------------------------------------------------------------------
�� � �N �� bu`�{It���.
� �..<t&. ��i�1"i Fg 4,..;t
SoSlding Department Services
September 23, 2008
Martin Haeberle
Chief Building Official, Town of Vail
75 South Frontage Road .
Vail, CO 81657
RE: PROJECT: Front Door, e�cterior doors and pool gate revision
PERMIT NUMBER: B06-0018
REVISION NUMBER: 22
INTERNAL REF#: 8825
ADDRESS: 151 Vail Lane
Dear Mr. Haeberle:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the
documents submitted to be complete for construction.
Plans:
Description: ASI B-056, 8%2" x 11's exterior door and pool gate revisions.
Plan review fee: $120.00
No additional square footage- No added valuation
Sincere �
-�---�
✓
John Plano
Plans Examiner
SAFEbuilt Colorado
john.plano(a�SAFEbuilt.com
Page 1 of 1
SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax: (970)328-1791✓V:�Plan Review\VaiI�F'ront Door�B06-0018\tov-b06-
0018.Rev22_FAL.doc
u
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED �
Buildmg Perm�t# �3� �l� 1
, 970=47�9���11�d���nspect�ons',)
i
���F�� ; REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, m hanical etc.!�
75 S. Frontage Rd. � � � (� M �
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plan o further ins ectio
will be erformed until the revisions are a roved AUG �� 2008 �
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Pho
�f c� C�ns� ' , � `l�a—�Dc— r3 �
A TENTION: JOE,JR,CHARLIE,GREG,CHRIS
Contra or Signature er.----,�
/ ' _
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor & Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea !e-count .com
Parcei�#
Job Name: ��� � i� � �� ��j,,, Job Address: �s� �� � ��c
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: V� � � Address: . Phone:
Architect/Designer: a�a�p Address: Phone:
Engineer: � ,/ Address: Phone:
I�POf � NRr/'G�•
REASON FOR REVISIONS: E�.(-,��C� G� � I _G gGM'� ����
�( �-QSlo
Work Class: New(�,)''� Addition ( ) Remodel ( ) fZepair( ) Demo ( ) Other( )
Work Type: Interior( ) Exterior( ) Both (��' Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
*************************************************FOR OFFICE USE ONLY**********************************************
Date Received': . ' ' ' Permit Fee 10 : ; : Plan Ck Fee`80 :
Accepted`By: t � Permit Fee;,(11): ; Plan Ck Fee.(81): - ;
Outsourced•Terms:
F:\cdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 4/18/2007
' ��w� �f v��� �G�O-Q�l `6
� 4240
o�Y
ARCH ITECT EM ENTAL - vAi�'s FRONT�ooR _
NSTRUCTION No. B-o56
� � � � �/ �° oug Thompson/ Hyder Construction, If1C. PROJECT NO: 20693.OH
D3 Santa Fe Drive issuEO: 08.04.08
�uG �� 2ooa
enver, CO 80204 FROM: )ason Ringdahl
i
'r'�w'� ��' �'����,,,_,._,�.43-825-1313 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructions
indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time.
Architect's Supplemental Instruction Title: Building B—Lodge at Vail Guestroom Door&Pool Gate Revisions
Reason for Change:
At the request of VRDC,change the locking functions and exterior doors into the Guestroom Suites at Level 2 as well as the
operation/locking of the pool gates. Revise the two exteriar doors at the balconies from the Guestroom Suites on Leve] 3 to be code
compliant(threshold&width requirements).
Description of Instructions:
1. Note that this ASI replaces ASI B-010 where the sliding doors were changed from 5'-0" to 6'-0".
2. Change doors B231b,B241,B251 and B310b from 6'-0" sliding patio doars(which provide a clear opening of 29.9'), as
denoted in ASI B-010,to a swinging door with sidelight. The door,sidelight and frame are aluminum clad wood as
manufactured by Pella(similar to doors used at the Chalets). Tbe finish is to match the other aluminum clad wood
windows and doors. The doors are to have a low-profile sill in order to meet accessibility requirements. Refer to the
attachments for additional information.
3. Change door B320b from an in-swinging door to an out-swinging door. The door is aluminum clad wood as manufactured
by Pella. The door is to have a low-profile sill in order to meet accessibility requirements. Refer to the attachments for
additional information.
4. "rhe doors noted above are to be provided with new hardware sets B45 or B46 that include ADA compliant hardware from
the door manufachirer,as well as VingCard readers which will be provided by the Owner and installed by the Contractor.
Refer to the attachments for additional information. The hardware finish(es)are to be dark bronze to match existing.
5. If the half inch maximum threshold height is not achieved per the attached threshold detail, install ADA/Code complianC
threshold ramp/extensions as manufactured by NGP,Inc. or EZ-Access. Refer to the attached product information.
6. The pool gates sho�m on 1/L208 are to be modified to what is shown on ASK 5-002.
7. The main entry/exit pool gates to the north and northwest are to be provided with panic bar hardware on the pool side with
an electric card reader/keypad on the opposite side, in lieu of a gravity thumb latch. The electric card reader/keypad will
be provided by the Owner and installed by the Contractor. Refer to the attachments for additional information.
8. The pool gate to the southeast is to be provided with panic bar hardware on the pool side with no hardware on the opposite
side. Refer to the attachments for additional information.
9. The pool gates to the Guest Rooms are to be provided with an etectric card reader on the pool side with a lever on the
guest room side. The electric card reader wi11 henrovided b�the O�xm___�_r_anr] �n�+a�led by the Contractor. Refer to the
attachments for additional information. ������t�t�t�, D`�,� � /�P������
10. Change the swing of the southeast pool g te to swi t. ��� �'� �� Subject to inspection and Compliance to all
— —�� �` relevant Adopted Build� and Municipal Codes.
� Changes in Plan� U be roved.
a �`rF-j,f,j
��� � 3 v�_ : c�
I � � Date �'Z�- _� BY
42�40 ARCHITECTURE INC , i '
; �_____--_ f � �Oa2: �G� Cs���
1621 Eighteenth Sveet � � SAFEb�.iilt ColoraC�O
Suite 200
Denver,Colorado 80202 The information contain' i message is privileged and�confidentlal inle3ec7only for the use of the individual(s)or entity(ies)named
t 3032923388 f 3031923 1 1 3 above. If the reader of this message is not the intended recipient,you are hereby notifed that any dissemination,distribution,or copying of
www.4240architetture.com this communication is strictly prohibited. Ii you have received ihis communication in error,please notify 42/40 Architecture,Inc.immediately.
� 42q.o
Attachments and Enclosures:
-ASK B-185,ASK I3-186,ASK B-187,&ASK B-188;all dated 07.25.08.
-Partial Door Schedule and I-fardware Set 45 and Set 46; dated 07.25.08.
-NGP,Inc ADA Compliant Interlocking Ramp cut sheets(3 pages).
-�Z-Access Rubber Tlireshold Ramp cut sheets (2 pages).
-ASK S-001 &ASK S-002; dated 07.25.08.
�� Copy To: ASI File
By: Randy Hart/4240 Architecture
Rick Caudel/VRDC
Sub it'to Town of Vail: � YES ❑ NO
� .
42�90 ARCHITECTURE WC -
1621 Eighteenth Street
Suite 200
Denver,Colorado 80202 The informalion contained in this message is priviieged and confidential intended only for the use of lhe individual(s)or entity(ies)named
t 303.292.3388 f 303.292.31 13 above. If the reader of this message is not the intended recipient,you are hereby notified that any dissemination,distribution,or copying of
www.4240architecture.com this communiwtion is strictly prohibited. If you have received this communication in error,please notify 42/40 Architecture,Inc.immediately.
�� B 53 , �,�T., � — �5��
CL . B231
1 �❑
— _ W,�. GUEST�ROOM
� - 234 — —
CLO
� � _ �� � _ B233 B2 2
_f 184 0
GUEST ROOM F�EL. —� � 231 b
� _ GUES�T�ROOM �
8241 I
_ � .
B — / � —
/ — �
� _ � � - - � / // '
I � - -_ _ _ _ ��
\`� - � - � �
/ • .
1� - -
, , - . __-: ,
, ,.;,
-� _., — , ;, �
1 ; i -
� � � -
- � �, ,
� — � � �
� �� � �
\ - - - ��
� � '�- \ •� ,
� � � – – �
� 1 � � _
� � RE: ASK S-001 & ASK S-002 I �
�
FOR GATE REQUIREMENTS �_ //
�
� � � — � ____ �
-� ' � - - - - - - _ — .
� � � - _ �
\ � � - �- -
� - � _ � _ �
� _ � , -
— i � �� _ — — — } , ;; .,,�
/ \ / � ,� a
I � �� � � �` �,''�°°A:�`� - ;
� � � � ��
I ` � C,��`- �� �� �j�
� � � � � � I I f�� %�1 � � 'o!^R n� , �t �,'`1
� � � � � 1
" � \ � � � �� ��<<,, :. . _ ,�3 j,
� �I � � �°,� 6 _ h f,
I � "` � � � �,
� I � ,//f 1 _.0\O � II 1�C�� ��.�a,� ; � /
"�� 'i:� �i�
t 8
�����Y, � _ ����
SPA / GUESTROOM SUITES � �--�
1 FLOOR PLAN — LEVEL 2 EL 8182'
��
,,��„««°r,�«°,� Vail�s Front Door o�nw�NC No: ASK B-185
424o p«„�r/n���1op�� REFERENCE: 8 — 1/A102
Vail Resorts �SSUE: nsi B—oss
Develo menC Com an ��� ���5�08
P P Y scuE: �/a" = i'–o"
Drnvcr,Color�do :Avon.Colorado �f�� �: �R
, i „
� C=—
�' B4 — 95'-5"
F . EL.
� _ _ 1 __ GUES�M g300 CLO
� 1�C RAMP �
1 pN
B 06
I
E STAI R G � 1 N
,
CLO � yJ - S
� CLO ,=�7Y R
�i � TAI R DOR g 5 '
, F.F. EL. �� ,'
B322 ��_-_ _ � B303
.�--
y� BATH i B310
8323 � �� YER � I
`� � � �
— i �_-_ �_ _ —
� 1 / I— 0 i B TH — LIVING OOR M
I 1 , 1 B��_ 3 'i, — �,° � 1
�_ —
� B321 B � BEDROOM / ❑
— � —
� B3
W� BAR � I Efi AR
B311
1 � I _ I� B311b Q �
—
�VI ROOM
0
I I � 32 b _ — _
-
—
� ~� �r�i,T�.
_ � �y� l� ".�d�e,?�
� I �� E�.,�:,.' .,4,��,.
. �
�— E.. `��",;•"'1—
_ � ' 1
, �,,:�, a
� � ,1
1 ��>:'���J���V
, g.,,<--."-,r;;
' �/ �.r��.:.�.....u"d ��'� „�� :�
C�'y. z
' ��� }A a)� ` ,%.
� ' r'
1 � � � '
SPA / GUESTROOM SUITES
2 FLOOR PLANS — LEVEL 3 EL 8195'
�«�,��°��°�R��°�� Vail's Front Door ��w�NC No: ASK B-186
4��� ����„���/D���d�,p�r REfERENCE: B — 2�A102
Vail Aesorts ISSUE: ASI 8-056
� Develot�ment Coiny�an� ��� ��25�o8
Dcnvcr,Colorado C C � $G��: ��8� _ ��—��
iAvon.Colorado DRAWN BY: JR
FIELD VERIFY (TO MATCH EXISTING CONDITIONS)
AS SCHEDULED
AS SCHEDULED 3'-0" FIELD VERIFY (TO MATCH
EXISTING OPENINGS)
z \ . // z \. /
O \ / // � \\
� /� � /
z � z �
� � �
� �
w ox
o w
J = / J S
� CJ / � U
� Q � Q
= g S �
cUi� O c�n O
� � \
� \ �
Q } \ Q � \
t,_ \ \
� �
w w
> >
� \ / ° \
J J
W \ / �'J
� � \
\ \
TYPE G TYPE H
Clad Wood with Clad W. � �tf��;�
G l a ss �,��� ¢ '��:����
� �
E. �:��?�.�L
Jur-�i�v��l
1 D 0 O�R � TYP E S � ���, ��.� � '
r�'�,,, ��.�
�'��'� e� � � ``,
.� i
,�«���««°ER��°�� Vail's Front Door oRAW�N� No: A —=i s`�
4��� O�rner/Dcvclopa� REf���E: /161�
Vail Resoits ISSUE: ASI 8-056
� Development Companp �: j�25/081'-0"
�
Dcnva�,Colorado . . Avoq Colorado �RAWN BY: dR
EXIST. CONC TOPPING SLAB
OR PAVERS
NEW CLAD WOOD DOOR
NEW DOOR MANUFACTURER
PROVIDED LOW PROFILE
SILL/THRESHOLD
EXIST. CARPET FLOORING
OR TILE (RE: ID)
XIST. CONC. SLA�
��� �' FT. SLOPE
GUEST ROOM L ELS 2 & 3 _ -
- - (LEVEL 2 SIMILA . ,
< >o a'
e - — — — —
a d
a
0
a p �
�
Q a
a
NOTE:
1 . REFER TO 1/A503 & 3/A503 FOR ADDITIONAL
INFORMATION.
2. IF 1/2" MAX THRESHOLD HEIGHT IS NOT ACHIEVED,
INSTALL ADA/CODE COMPLIANT THRESHOLD
RAMP/EXTENSIONS AS MANUFACTURED BY NGP, IN OR
EZ-ACCESS (SEE ATTACHED). � � '
�
. �� 4 �����
'�,�' ,�`3�.
� �
GUESTROOM DOOR THRESHOLD DETAI �° `�`�'���^'L
1 , , z = , -o �-�-��,.�
J��-Si���:�V
�^��r
C.�,�` --���
�� �
���r: ��
��, .`•.�
��,� - ,�l
„�`\� ��i�1 t ,r`y
�r�h�««°ta«°,� Vail�s Front Door �w�w�NC r,o: ASK B-188
424o Q`n'cr/Dcvcloper RffERENCE: A614
Vail Resorts ISSUE: ASI 8-056
�� Deaelo ment Com an� �A�� 07/25�08
p p } SChLE: 1 1/2 = 1'-0"
Dcnvcr,Coloiado ;\��on,Colorado DRAWN BY: NK
� � � �
� � � �
� °p W W W W
° 0 0 � 0 0
� N
� �' 3 3 3 3 -
�
`� � � � � � �
a
0 0 0 0 0
N N O �n O O O O O
�`o mm � � � � � �
a w w w w w
� O Q � W W W W W
y •j � � h h H f0 l0
�t �t V' V' �1'
0 � y x �0 00 00 �0 0�
� Z
o �
0
° a�o ocoo o°po a�°o ocoo
p � � � �- �- �-
y F m �1 m m m - 0
Y Y Y Y Y �-
� Q Q Q Q Q Q
�
a O
� U
�-
m
� z � �C �C �C � t�i�
� LL � ti � � � J
LL J
Q
a � � � � � � � � � Z � � � � � �
� Q Q Q Q Q � � � � � � � � � � �
w
J U U U U Z U U U U U U
� > > > > � > > j > > >
2Z22m 222Z Z2
� W W W W W � � � � � � � � � � �
LL � � � � � O O O O � O O O O O O
J J J J � O O 0 � � � O O 0 � 0
� � � 0 � � >- �- �- �- a W W >- >- >- >- W � >-
� � � � � � mmmmWOO mmmmomm
0000 � » 0000 � oo
Q Q Q Q Q W W W W Q O O W W W W O W W
O O � � � � � O � � O � O 0
» j � oaa » » a5 �
� } � � � � = 0000 � � � 0000 � oo
o � aaaaiZZ aaaazaa
0
� Y V V 7 V d'
U
= M M M M CJ
H
F
= O O O O O
C�
W I� r I� I� 1�
2 +I tl tl tl +I � �
_ ' ' ' ' - � �
m o 0 0 0 0 o Y Y
� � ih iy ih ih <`'> U U
� O O
a
� `� W � W �
m W � 1= � � � 1= NN
� > � �
o w i� a�O � WY W m � WY
� ZJ � � � � � � °' � a ° o � > a ° o �
W � � � O O O W p p ;= Q OW � z � Q � W � ZO
,� o � � o 0 o Wo o � o o � � � w o o3 °� � w
� ` o p � 0-' � � J � � W 1� (/� = � QU � I� fn = � QU �
A yri J � � � � � C� C� ,c C� WJW � VWcQi� C� WJW � VWy
W _ � p � w w w cn Z Z � Z � Q � � C� � v� 2 � Q � � � � <n
'xi coo ov) > > � � > > m h Z ? W = OZOQ co Z ? W = 0 ? � Q
v > N owc� c� c� oJ J � a W = �n � o > � a v W x �n � o � va
� �
� O C7 � I� h Q F� Q
a V Z Z a� � N � � II W = � W �
� � � Q ch V in W O O W � U QWQQQ N U QWQQQQQ
0 ° ° oaN N c" � c� c� � � Q W �nWWW � Q W �nWWWWW
A a a o <n m m m C9 m m i- = W �, .- �- �- .- o 0 2 W M .- .- .� o .- �-
:
.. . `�� �'��'���eo�� (>�r��Js' l�� 3�
� � ������� a� -�� ��������������fl Phone:800-647-7874 � �Erv;�!.;ag£..cui,�
Tltc prrduEL;You ct1E nc=9'�The),�optc yoa;tru5� Fax:8D0-255-7874
� �t�. '"'T°",..�"'��.�Yib+'T�4�rt:� '.x °�'s�3:��'�a�:C��:.S.��"r.['�x;` -�m.qi..t,...i$a'J.�.,'L`.'�' 'M."'?a,r'�n�.:r'E'.:`'i'.'�rJ'�`.�.�.�.�>z�TS':�7Y�s'.�. ."�c-,.'.:...5'r'_�1�k'3!.+"�"d's"�'°"�':H.�is.'ir.r*�1'.,F7Ti)Y,+1i .
--_'.__....,......_..-.._. '�' � �
�� ""''� �5�� .94 fbslft. Typical Wall.110
�' ' �i�pL?K's� .v4 ibsirc ��z" `-�Q�- Af{produccs pages
!.� 1 ' T16 and T!7
���� �r �
� : � � � �
�:� �:
; 3/4" ��l� 1631bsJfc �.
�" � Se7ST�`2i£� L63 ibsltc Illustrations shown at 5Qq
9" —--
�. : 1
_ ;�
,..
�:'� _�� I R I t�0 2.06 IbsJft.
��..-: ,�y .;� 1 �C':74���`�n 2.0616c.ih. 12�� _ __ .
�iv
':;�k+F r
� I
::xKni..:.
''�`� . l li4'
�_ �, ' � �{2; 2.77 Ibslt[.
� . l ���zsC�Y�:�1 z.»ics.,r�. __
,E,�: - -- ;5:,
,.
__...,. .:_:i_:��.: '
� � �� 1 �.
__ _ . �.�_:
�_.-� N
kiX ' �
�al�t} 3.8ZIbz1k.
� � �� � �t f�D�'+i4#� s.az ms n�_ -
�-��.� _ — i a„
i,��._�I
I
Q
� �
I :�i i$ 4.53 Ibs.lfc. �
I
� i :?175ES�.� 4.53 Ibs./fc.
' ._:.... __ 21..
y .
�
�� ...::��. N
I
1 fi2f}� 5 58�bS,Ft i
Q�ai���K�3 5.5816s1ft. lq^ ___
�
c
� �
. � R�2c 6.3716s1f�. .
,�M�SUS��S=S 6.371bsJfc.
?��.
�
�
iv '
� f:
N
" .- 1 }'��5�3 7341bsJfc. -
E22506�It� 7.3416sJft.
_ ,,:.i<'__.' .:; 30,�
'T I b `_'"_"_ —
�� ���
� Phone:800-b47-7874 � a�av�✓.ng�a.ran�
FaX:aoo-iss-�s�a ' � �-� �� � � � � �, � � _
� .r� -, -•�� �, •
�� • rs � � ,� � � � �� � .�.� �,_ � _ _.. _
w • �.
,. , .
' �, �
� �� -
..��,� -�'�� _ . . .�, ,�� ,,� _ -� ; ..
���.�,°���t ��.������-� �:����;�� ��� ����2���
k-,.
�,.
uY Return closedvends provideyan�attractive finishzd appearance co �
ra�nps. They are available in several lengths and can be crimined to `�
accommodate any size ramp assembly. ,y� �
RCE's are also available wi[h slip-resistant"SlA"finish. �e�� lek hand recurn `Y
� o iilusuaced _
0
�_�� � � �� j .
, � �
�� �
.�v�:�-'7 �- � � t°�
�,s:�-9C5�i� 14-� '
F�----- ..�} .
c� [
'' `=`..:','-.
--1 :�f.C'°i�3 � � � � f]
;tr,��-1�L°r►�.§�
15" i a
3,
si�T� 2 i � �
:,�'� LIC3's:ka � � � �� �+�`
J ,.� _
zr - � :y
-t
�;a
� � �
�z-
�XC�-30(indudes RCE-21 + 12" extension)
k'�i;L-3�C;�[�r(inctudes RCE-2i + 12" extension)
MATERIALS&FWISHES
�Aluminum mill finish
� •DKB-Alwninum dark bronze
finfsh
Slip Resistanc SiA Finish ��
---� qll chreshoids are available wich �� �
our slip resistant,non-skid finish
;
for becter vaction.Suffix"SIA". . ..__;;�, ��..
'FJ7;
�� �� �
Phone:800-¢47-7$74 tir�t�v,�.n9�i.cer�;
�
- � fax:soo-ZSS-�s�a � § ��� i� � � E� �3 �. � �
� _ - .� ..;� -o`
_.
��:��,:.�:�����. - �.�, � � � z, � `
�.��a�B��,B�; ����'s�3�
_.-�x- .�....�.a=,�_��.x.�-: _.-��,..��.��....,�.c.�.���..�...A«�..��.._� �`"�� .���r � AII aluminum ramps �-
i� � � ��
this section
MATEftIALS&FINISHES
,=i
•Aluminwn mill finish �
•DK8-Alumin�m dark bronze
finish
i �
Typic I Wall.925 Slip Reslscant SIA Finisli �� �
N '
�
1 All thresholds are available with �, -
� 4" our slip resistant,non-skid finish �s
�S'� .53 Ibs.Hc. ior better traaion.Suffix"S!A". .
b5�C3:S,F3 .53 i6s_llc.
�
N ......_....�::.......'�:.
1 Typical Wall.125 -
i 6,. -
,r�� .86lbs.i(c.
�ST�E�C� .861bsJfc. ,-� � �,
+
T,
�
i Typical Wall.125 ��
N fa:',� .80 fb,lfc "when used with 657 N �
� f'+5�'�1}z.L� .80 IbsJft. t�
��� �
����:������������ ��.������° ����������.�-��.,K.,..�.�.,��,
�` SuppGed with beveled ends- (end slope= 1:2). Specify if straighc cuc is required
` Rubber ramp sections may be combined wich aluminum ramp componencs for higher rises.
or wi�h b"flat aluminum fnterlod<ing threshold#957 for various oHsec condicions.
r Black silicone adhesive a�ailable to secure ramps withouc fasceners. Specify RR5007BL, _
each cube wili secure 2 ramps 12"wide x 36"long(b square feet.)
i
1 `�
,2"
C�r'�,�w 3416s1(c � - ��
maximum length= I 18" ��.'� � �
Slope= I:12 ;y "
114us�racions shown at 50% '� �' ' '
1 � ....:.:�:::-.:_::'..,... .
6��
- �$Z7�� I.OIbzJfc �
maximum length°120" � ;
— --- T 21;.';_
� � � �r�e��o� �� � <�.�2}
�� �
�..�Y, ,�,,�-�.y —.�...---..- �U _ E� TH�ESH�LD-_ A�P
�.� -_ _
:,,�._ �.�.��.�..���_... ___._..�.� ..__ .
I �I ��� . � ,� Ramp simply sits again5t the
j
s� -� `�� �� � ' doorsill(inside or outside}to
a. �_ °___�n= : �
� ��-,_,�-_..a. - . :-x.
,rr-•..-..._��n.-
�'�s��=°��;: � ' provide a smooth ground-to-
�r_,_.
�i�:°- •
"--`-'°`='�"� ' x ,;i-- sill transition and is espeaally
-���-�'�-� �
�;-, +; practical for sliding giass doors
because it does not interfere
� �`� - - with the door track.Made of
, : � � � � � � ;
- �`�� k- �,�, � . 100%recyded tires,EZ-ACC[SS
�� Rubber Threshold ramps are
- ADA approved,slip-resistant and
s,� , designed for years of continued
� ' use.Standard width is 48°(for �
wider entrances,simply place
�,» ° 2 ramps side-by-side).Ramp
•, �.
can easily be trimmed for lower
I,P��hts and widths to fit any
t �;=� �. ���,��, entrance or threshold.ldeal for
'`���`��-=-� - ' indoor and outdoor use and, �
- ~Rw'�.. r_ -
�,..,.:.�;. : �_ _ �,�� ° because it is fully portable,can
�- . , easily be moved to another door
:, � �' �� ��-���=�� "�
.�
,�, � , _. :�"�~ r � �; � or location if desired.
f'=���`� �" � � ��=��`��,_�'��"��,�r�`� .._
- :-=�. _.-:.�.._. .'� . ...
. .. :_..
-���: R '
�
=".+�._
�
,...
�.r,. ,....:.
: � i� d i
.. .
...__ , :...,: . .-�, . .. �.�.,_i
.
.: . _.,�::.. ,
;.,: ... ,�ne��t . ' .i,�t> .'::'+�
...
_..,_, __.- ,,:- .. ..
�-- ' � �r�.��. �.c&
�_I.!� .:- .
.._ . ���- : '�i�.;,
';.._ ...,. . .. „-�, .:...: :`i t :..
SPEGFICATl�NS THR 150-1 7HR 250-1 THR RISER 225 iPR :
Made of recyded rubber _ . • __
__. ___
_ _ .
Non skid surface ' _ . --
UsablesfzelHxLa4��1.. . ... .. � � x��4'��'xa8' -- 2;�i'x24"Y48" . � 24'x2-7'(t�voeach) .� .
Weighc(Ibs.)' _ _ 18 - ,. 4� Z>b5 per riser(two eachl
. x..
Weight capacity(Ibs.} 850 �l� _ 850 �j(i _ _ 850 �$f _
For velieelchairs&scooters ' � _.. - . -
Usage guide{ine�"' 1'h"rise 2I5"rise Call customer service for details
* VJeights are approximate and may vary.
rfi Optional components available ro reach heights grea[er than 2!':".�all for details.
Consult your equipmenYs owner guide tor proper degree of indine.Never exceed its recommenda[ions.
'�" i � ,_ ,, �UPSShippabie
�.. :�:: � _',� �,,;.; � . _.. i .— -
.y�.:,: .... '_
.r �v- .. .. .-. ..: . .
:�8 `d .�t.,.�:�_:�. _-�---.... ,i .___.. .... _ . . . .
. �� � � `
.I.�. �z-.�cc�s� RU BER THRESHOLD RAMP
{��� _ Available in 1'/z' and 2'h" heights (optional Risers also offered)
INSTRUCTIONS FOR iNSTALLATI�N AND USE
BEFORE YOU BEGW SECURING THE RAMP:1t is recommended that the Rubber
i. Maximum weight limit is 600 pounds. Threshofd ramp be secured to the surface it is laying upon.
2. Read and foNow all instructions before use.Do not use if ramp is i. ATTACHfNG TO WOOD
damaged or unstable.�or wheelchairs and scooters on1Y Ramp is not a. Place ramp in desired location and ensure that surface if
intended for commercial use.1MPORTANT:Use ramp only with a free of dirt and debris.
qualified helper and always use your lap belt. b. Secure ramp using supplied Phillips head screws(2
3 WARNING:It is important that you refer to your equipment's each).Space screws eventy(see DIAGRAM 2 for
(wheelchair or scooter)Owner Guide for lhe proper degrae of placement)and drive until head is%+"below the ramp
inclineldecline and chair direction before using ramp.Never exceed its surface.
recommendations. 2 ATTACHING TO CflNCRETE
FlTTING A RUBBER THRESHOLD RAMP:Ramp can be easily Uimmed to a. Place ramp in desired location and ensure that surface if
accommodate lower heights and narrower widths and,if necessary,notched free of dirt and debris.
to suit the doorjamb configuration.Attemately,ramp can be combined with b- Secure ramp using supplied Phillips head screws and
an additional Rubber Threshold Ramp and one set of Rubber Risers to concrete anchors(2 each).
create a maximum height of 4%". c. Place a cardboard template under the ramp,then install
1. If door threshold is equal to the height of the Rubber Threshoid Ramp screws in locations shown in DIAGRAM 2.Drive screws
(either 1'/�°or 2%:"high),use Threshold Ramp as is(see DIAGRANi 2, until they penetrate the cardboard template(top of screw
section A). will be roughly Y<"betow the ramp surface).
?. it door threshold is less than the height oF the Rubber Threshold Ramp d. Remove ramp,but DO NOT REMOVE SCREWS.Using
(either 1%"or 2'h"high),trim ramp to lhe desired height,depth and/or the hoies made in fhe c,ard`uoard es a yuid�,dr;,,4^�!'�:
width using a reciprocating saw,razor kn+fe,or hand saw(see holes into concrete using a 5/16"masonry bit.
DtAGRAM 1). e. Remove tempiate,then insert anchors into concrete.
Drive each screw into anchor until the screw head is'/<"
�WARNING:Use caution when operating any non-manual saw as below the ramp surface.
serfous injury may result due to unexpected binding or pinching of rubber
ramp materiaL Always follow tool manufacturer's safety guidelines.
3. If door threshold is greater than the height of the Rubber Threshold
Ramp(eilher 1Yz"or 2%z"high),two Rubber Threshold Ramps{as DIAGRAM 1
shown in DIAGRAM 2,sections A&B)along with one pair of 7hreshold
Risers{DIAGRAM 2,section C)can be combined lo accommodate a
rise up ro 4'/<"high. r '`=.!a`"
.'�;�
a. When creating greater heights,an additional Rubber Threshold VViDTH rf,��3� �"
Ramp(Section B of DIAGRAM 2)will be used NOTE:With this �� s
configuration,Section A must remain at its ori inal heiqht(ok to `"��� "���� ,
9 �.z�,�'n`�^'�.s� �r� s ��`�` tv
trim width only). '� � ��a-�.� ,�. „�.,.�`�+, c+£�`.
b. Section B,as shown in DIAGRAM 2,can be tnmmed to the desired £ z ;,�, ,,,�{��;��� � � �r -,�,
height,depth andlor width.If Section B is trimmed,the Rubber �-'?,k-;;r;��g,,k-•`'
ftiser(Sec[ion C),used to increase overafl height,needs to be H�IGHT
trimmed to match the depth o#Seciion B. pEP��
c. Secure(Section B to Section C using suppfied Phillips Head
Screws).
'`^�_, �i� �
?-� �{�7���4 x-'� _ ,
4 �
DIAGRAM 2 ; _.�` ������� ���
i ���°�*����.������,��.
i �. � ���.f- r �s�
�..�-���� �`\ ������ h���
.-r`'" � '� ��' y�'�''�,�� �
v �.�'��...� s��, �� � } ��"�'.� �,,,-���r,�
���''�r^'�''t�`��}7't�¢ f� '\� �ys�,^-°'�t`Yr?o-��`����f F�`.r'-.14r s
�� -; ,.�.�+w�''��r�'. � � `` �'�`,� �"`�y��9' �,�'�
M������x_Z�"`-*�z w�.�' ' ". �, �`�•���'A r'rx����
'��'�'�;���`� 4'f'd�`-,�� �:���-�'�-,
�� \
��!; �t 4 ��_���i���\ \\\ -�'.
`\i -�4 ?2,...Y q� I�'.. `' \. ��� �,g�
� `4.�m���,�, k11�?L � `�.l ��,.r' .
� Y Y:Y;
\}"a xa}�`iL.a.4�X1.�'; 'k'��� � �
h
��e'1 �57�£�a'��� � � ��
f v�� �'�����`' (('} GC
`./ �yo- ,�s�
1 YEAR
�qRqA��
6450 REV 02-08-06 One-year limited warranty.Call 253-249-1101 for details.
OO 2006 Homecare Produc[s,Inc.AI rights reserved.
a
0
_�— —5--__k_
—'�" , �"_-��
�--_ _� ~�;� -
��
�� ►
�RE: 2/ASK S-002 —
_ �
_... M... ...
t ,
O '
� � < µ � �
c.
, , �� t
j �ik A
,r .�—':`
� ( ; i sk; � RE: 1/ASK S-002 �
,;;
�,,, ,�,
�, ��'i
�� — y�.:.:��� } �
�'� 3'4��, ��_ �
� � �}
RE: 2�ASK S-002 �;�
�""' BUT WITHOUT ,� �
� � CARD READER�
- HARDWARE ON —
;
, .
OUTSIDE , I � -� -
r�
iv f+� � �t��''�.c, e
� , � " c.���`; _, �`e'.
1 PARTIAL SITE PLAN e. ;�,�,!�,+���,�
J�3�-���uz:aEJ
/ ���� �� �
e '/�'c� ��r f,
�� A�
�,��„t«<<,FR«<�«� Vail's Front Door o�u,wiNC No: ASK�`��=o �
4z4o o���,��/t�����l��p�� REFERENCE: L202
Vail Resorts �ssuE: ns� e—o5s
Develo ment Com an r OATE: 7�25/08
D�„�-<,,co�or,ao p � � scALE: t = 3a'—o°
,\�on,Colorado DRAWN BY: JR
1 '
METAL FENCE & GATE AT POOI/SPA
DECK (RE: 1 & 2/L208)
GATE MT0. ELECTRIC CARD READER
(VING) ON 'OUTSIDE' OF GATE, BY
OTHERS
� -
WEATHERPROOF BOX & KEEPER
�, 6„
� SURFACE MOUNTED PANIC BAR ON
i
'INSIDE' (POOL SIDE) OF GATE
(w/VING LOCK OVER-RIDE FOR
� EXITING FROM POOL)
i
�
ROUNO HOLE PATTERN (3/8" DIA.,
1/2" STG. CTRS, STRAIGHT-LINE
PATTERN) PERFORATED METAL
APPLIED TO POOL SIDE OF FENCE
GATES FROM POOL TO OUTSIDE NoTE:
1 SUor,4CE b"OU":?ED °f,N;C 9ev rp gr
�VIEW FROM POOL SIDE� —BY HOOVER FENCE CO3 OR SIM
—DELUXE KIT D-6045 w�LOCK BOX
�, POOL AND SPA GATE C� EXIT ENTRY -MOUNriNC P�nTE NoT NEEOEo
—BLACK FINISH
� ��2 — � � —LOCK BOX, COMPATBLE w/ELECTRIC CARD READER
METAL FENCE & GATE AT POOL/SPA
DECK (RE: 1 & 2/L208)
LEVER (w/VING LOCK OVER—RIDE FOR
EXITING FROM GUESTROOMS) ON
GUESTROOM SIDE OF GATE
GATE MTD. ELECTRIC CARD READER
(VING) ON 'INSIDE' (POOL SIDE) OF
GATE, BY OTHERS
ece^`
�° WEATHERPROOF BOX & KEEPER
M . ,
ROUND HOLE PATTERN (3/8" DIA ^�-~—""`^�;.\
1/2° STG. CTRS, STRAIGHT—LW .- �� �e:� �g
PATTERN) PERFORATED META ��,�� �n j��, ,
APPLIED TO POOL SIDE OF � �,�" Ft�`..rJ;
��
�. i?S�St���l��
GATES FROM OOL TO LEVEL 2 GUESTROOMS s� �, �
(VIEW FROM POOL SIDE) J��m`e�`��°J
s.,,�,-,,..,� �., t
POOL AND SPA GATE C GUESTROOMS �°� ���� '
1 i�2° _ ,•—o" ��� ,-�
.` ,��f ::i;d�
�\�}f,; .�i � ,
v � �,, t-t'G %:
�. ,�' �"
Ir �
:�"h„"">ER""`d V t�.11's Front Door DRAWING N0: ASK s-002
4��� O���ner/Dc�-cloper REFERENCE L208
Vail Resoi[s ISSUE: ASI B-056
Develo ment Com an� DATE: 7/25/OS
Dcnvcr,Colorado p p � SCALE: 1�2�� = 1�-0��
\�-on,Colorado DRAWN BY: JR
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-213 8
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
NEW COMM BUILDING PERMIT Permit # B06-0018
Job Address: 174 GORE CREEK DR VA1L Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 02/10/2006
Parcel No...: 210108278002 Issued . . : 10/02/2008
Legal Description: Expires . .: 09/O1/2009
OWNER LODGE PROPERTIES INC 02/10/2006
PO BOX 7
VAIL
CO 81658
ARCHITECT 4240 ARCHITECTURE, INC. 02/10/2006 Phone: 303-292-3388
1621 18TH STREET
SUITE 200
DENVER
CO 80202
License: C000001868
APPLICANT HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
CONTRACTOR HYDER CONSTRUCTION, INC 02/10/2006 Phone: 303-825-1313
543 SANTA FE DRI,VE
DENVER
CO 80204
License: 109-A
Desciption: Town of Vail Adjusted Valuation: 7,739,000.00
CONSTRUCTION OF A 3 STORY UNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Occupancy Type Factor Sq Feet Valuation
STORAGE/LOW HAZ (S2) ZONE 3 IA 115. 18 108, 815$12, 533, 311 . 70
Totals . . . 108, 815$27, 739, 000.00*
Fireplace Information:Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
****�**a*s**►a*:�**►s*�***�s***�.**�*******�s******�*******�ss:*****FEE SUMMARY *****�*********as*r*r***�a**********************x*s****
Building------> 10 3,2 0 6.10 Restuazant Plan Review--> $0.0 0 Total Calculated Fees---> 2 0 6,415.2 0
Plan Check---> 103,206.10 Recreation Fee--------------> $0.00 Additional Fees----------> S1,322.97
Investigation-> S 0.0 0 TOTAL FEES-------------> 2 0 6,415.2 0 Total Permit Fee----------> 2 0 7,7 3 8.17
W il1 Cal1-----> $3.0 0 Payments-------------------> 2 0 7,7 3 8.17
BALANCE DUE---------> $0.0 0
*:***s*a***ss:ts*�►s******x�***x****�*xs*+***as�sas+****+**x*►*s*****�***a:*s**:�*a«a**s:�*****�***:s:*a******ss::*******a*<****■*�s**s**s
Approvals:
Item: 05100 BUILDING DEPARTMENT
05/30/2006 MROYER Action: PA Approval is granted for Grading, Excavat
Shoring only. Other approvals required prior to approval of full building permi
approval
required prior to issuance of partial permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
07/11/2006 MROYER Action: AP Full building permit pending conditions
department sign-offs .
10/02/2006 MROYER Action: PA Rev. 1 - IR #1254; approved structural c
Additional $0.
11/13/2006 mroyer Action: AP footing revision for crane #1
12/22/2006 jplano Action: AP RFI No. A-112 approved. 1 hour plan revi
$60 . 00
02/07/2007 MROYER Action: AP Approval for temp. stairs on East end of
Tower.
Additional Permit Fee: 148 . 48, Plan Review: 96. 51 . CIA o per contract Permit fe
and
Plan Review: 77 .21 . Total fee of 244 . 99 must be collected prior to release of Y
03/Ol/2007 MROYER Action: DN Revision 5- Dock levelers . Comment lette
to
Doug Thompson and Neha 03/Ol/2007 .
04/13/2007 MROYER Action: PA Rev. 5- IR# 2971- ASI A-017 Add dock le�
improve loading dock.
Billed 1 hour @ $60
04/17/2007 MROYER Action: CR Rev. 7, IR-3090- Ramp elevation clarific
comment
letter sent to Neha. 04/17/2007 .
08/27/2007 ependley Action: AP Rev. 11, IR 4225-Grade modification/ accE
no
additional square footage. Plan review fee $300 . 00
09/17/2007 ependley Action: AP Rev. 12, IR5441-ASI 5-026 approved. No adc
valuation.
Additional plan review fee of $60 . 00 due
11/13/2007 JPLANO Action: CR NEED ADA ACCESSIBLE STALL AND ACCESS
11/26/2007 jplano Action: AP Revl4, IR6037, Temporary Restrooms apprc
hours of plan review due.
11/30/2007 jplano Action: CR Correction letter sent on sign package
12/18/2007 cdavis Action: PA Partial approval for Shoring System Fina
and
sign off from engineer of record
12/27/2007 mroyer Action: PA rev. 6/ir3089/ steel deck clarifications
be
issued. no additional fees.
Ol/17/2008 mroyer Action: AP Approval for Rev #7 3090 Elevation and �
Elevation
clarifacation with new ramp detail
02/05/2008 jplano Action: AP Rev. 17/IR6346, Letter from Koechlien on
Inspection and Letter from PCL on adjacent building monitoring approved. No Cha
03/12/2008 sgremmer Action: AP Rev. 15; Approval of sign package ref#61
03/24/2008 nchand Action: AP Approval for ASI-5041 IR#6556 B06-0018 F
EXTERIOR HEATERS
03/25/2008 JPlano Action: AP Revision 17 (6346) special inspections �
Engineers have been received and are ok. See SAFEBuilt letter in file dated 2-�
lcampbell
05/20/2008 NSC Action: AP Approved B06-0018 ASI-028 REV.20 IR#756�
of
plan review due, $120. 00
08/25/2008 jplano Action: AP Temporary Exit plans dated by SB Aug.25,
approved
$120 . 00 due
09/23/2008 jplano Action: AP Rev22, IR8716/Temporary exit plan for cor.
offices, ok to issue after fire department approval
2 hours of plan review due=$120 . 00
10/14/2008 jplano Action: AP Rev23, IR8825/This is a partial approval
�ASl �-U56) - L hours ot plan review due=�1�U . UU
Item: 05400 PLANNING DEPARTMENT
05/30/2006 George Action: PA This approval is a partial approval for
shoring and grading only. Addtional approvals required for building permit.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
07/14/2006 George Action: AP
08/24/2006 George Action: AP
12/20/2006 George Action: PA This is a partial approval for the const
a
temporary stair to provide emergency egress out of Lodge Tower South. This stai
temporary
only and shall be removed prior to the issuance of a final CO
02/06/2007 George Action: PA This approval is for the addition of loa
levelers only
03/05/2007 George Action: PA Building A. This is a partial approval f
clarifications to the stell decking only. No other revisions are permitted by t
approval.
03/05/2007 George Action: PA Building A. This is a partial approval f
in
footing elevations and the slope of the foundation.
11/13/2007 GR Action: AP ASI S-038 TEMPORARY TOILET TRAILER PLAN
02/19/2008 GR Action: AP Rev. l7/IR6346, Letter from Koechlien on
Inspection and Letter from PCL on adjacent building monitoring approved. No Cha
03/31/2008 George Action: PA This is a partial approval for a revisic
ski
club patio area to add outdoor seating, changes in stair design and a modificat
swinging gates.
09/02/2008 George Action: PA This is a partial approval for the addit
lock pool gates and a change to two patio entry doors
(ASI B-056)
09/03/2008 George Action: PA This is a partial approval for site work
modifications
to the parking garage "snorkel" wall. ASI 5-042
Item: 05600 FIRE DEPARTMENT
05/30/2006 mvaughan Action: PA partial approval for grading and excavat
Requires fifty percent submittal in 30 days, 100 in sixty.
06/Ol/2006 CD Action: AP PARTIAL APPROVAL-EXCAVATION AND SHORING
07/13/2006 mcgee Action: AP Approved subject to Admin Mod and MOU' s.
02/14/2008 McGee Action: COND Provide detailed plans for gas shut off
portable
heaters.
Provide detailed plans and new mechanical plan for fire pit.
Provide review by BCER for fire exiting due to changes in sidewalks per origin�
Landscaping shall not obstruct access to FDC or Knox Box or fire hydrant.
02/20/2008 mcgee Action: AP ASI 5-038
02/20/2008 mcgee Action: AP
06/23/2008 mvaughan Action: AP asi s-042 for retaining walls
08/05/2008 McGee Action: PA ASI 5-041 Partial Approval: No data on f
appliance or shut off other than note to "comply with Building Code" .
10/Ol/2008 mv Action: AP
10/Ol/2008 MVAUGHAN Action: AP Temporary exiting plans for temp office�
Item: 05500 PUBLIC WORKS
07/14/2006 tk Action: AP Approved Building permit revisions datec
6/16/06 and 7/06/06
11/14/2006 tk Action: AP Footing for Crane-No comments
02/06/2007 tk Action: AP Approved ASI-A-017 for installation of L
Levelers.
Plan received 1-31-07, dated 1-29-07 .
08/14/2007 tk Action: AP Approved revised Final Grading Plans dat
received 8/8/07 .
06/30/2008 TK Action: CR ASI 5-042, Site modifications requires t
following
corrections :
l . The retaining walls behind the path gate and the Fire Hydrant at the
cul-de-sac are required to be no greater than 6' per Town Code, please revise .
Item: 05550 ENGINEERING CIVILS
.***...:****�*+..**«**�********�****�****:::.:.:.::***:**::::+�**:::*.*::.+*+.*�:***********.**:**,:.:**::*:�*:**�**�*:,:*�,::*****.:.***
See page 2 of this Document for any conditions that may apply to this permit.
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot pla�
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereta
REQUESTS FOR INSPECTION SIfAI,L BE MADE TWENTY FOUR HOURS IN ADV CE Y TELEPHONE � FROM 8:00 AM-4 P
SIGNA F O ONT OR FOR HIMSELF AND OW�
PAGE2
********************************************************************************************************
CONDITIONS OF APPROVAL
Permit# B06-0018 as of 03-17-2009 Status: ISSUED
********************************************************************************************************
Permit Type: NEW COMM BUILDING PERMIT Applied: 02/10/2006
Applicant: HYDER CONSTRUCTION, INC Issued: 10/02/2008
303-825-1313 To Expire: 09/Ot/2009
Job Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITEBUILDING'A'
Parcel No: 210108278002
Description:
CONSTRUCTION OF A 3 STORY IJNDERGROUND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE.ALL SITE
WORK IMPROVEMENTS AND LANDSCAPING
Conditions:
Cond: CON0008091
Response to complete plan review comments required to be submitted prior to June 19, 2006.
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
*********************************************************************************�**********
Statement Number: R090000240 Amount: $178.00 03/17/200910:14 AM
Payment Method: Check Init: SAB
Notation: 62240 HYDER
CONSTRUCTION
Permit No: B06-0018 Type: NEW COMM BC7ILDING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: 207, 738. 17
This Payment: $178.00 Total ALL Pmts: 207, 738 .17
Balance: $0.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300, PLAN CK - project GFP012 120.00
PN 00100003153000 INVESTIGATION FEE (BLDG) 58.00
-----------------------------------------------------------------------------
�� �� � b�u I
� � ., tir�c.
��� �����
Building Department Services
��,
'� 1��< .
4,
}..
August 25, 2008 rta�'��
���� �. '�
;�
Martin Haeberle ;r�� ;•s'
Chief Building Official, Town of Vail ���r�"KK�
75 South Frontage Road ��
Vail, CO 81657
��.;
.-�.x�,.. ��'
RE: PROJECT: Front Door
PERMIT NUMBER: 606-0018
REVISION NUMBER: n/a
INTERNAL REF#: 8716
ADDRESS: 174 Gore Creek
Dear Mr. Haeberle:
SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003
International Building Code Section 107 as adopted by the Town of Vail. SAFEbuilt Colorado finds
the documents submitted to be complete for construction after Fire Department Approval.
Plans:
Temporary Exit Plans for offices on site. ASI issue date 8/11/08
,-.
Plan review fee . • � T�`�- 'n.l� �' `i� ��f.F�.
No additional square footage- No added valuation
Sincere ,
John Plano John King
Plans Examiner Building Official
SAFEbuilt Colorado SAFEbuilt Colorado
john.plano cr,SAFEbuilt.com john.kin�(�a,SAFEbuilt.com
elofl
SAFEbuih Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue, umt lui � �,agle,l;oioraao�ibsl
Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax: (970)328-1791✓V:�Plan Review\Vai1�F'ront Door�B06-0018\Temp Office
Plan_FAL.doc
��o�-a��� �
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNS GNED ���°
Buildmg Per �t#:
� 97���`-��.��� p��fioi�s)
�
�WN��V,�:� A REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be performed until the revisions are approved, ***
CONTRACTOR INFORMATION
General Contractc,r: Town of Vail Reg. No.: Contact and Phone#'s:
�1 �� �.(�/U� C �C�� - �r�v� - .S/�
ATTENTION: .TOE,JR,CHARLIE,GREG,CHRIS
Cont�a i��ature:
�
COMPLETE REVISIONS EVALUATIONS FOR BUtLDING PERMIT Labor& Materials
REVtSED AMOUNT: $ � �� ELECTRICAL: $ �� OTHER: $.
I'LUMBING: $ MECHANICAL: $ REVISED'TOTAL: $
For Parcel# Confact Ea le Counf Assessors Office at 97Q-328-8640 or visit www.ea le-count .com
�'�r `��}#
2- � �
Job Name: `�, � r _{.. Job Address: �� V�� �
� I � i��v✓�l- �)Ir
Legal Description Lot: Block: Filing: Su6divisian:
Owners Name: �'RD � -� Address: . Phone:
Architect/D�sigiie�:��4� Address: Phone:
Engineer: ��ra� �- N.�.91GII Address Phone: � �
REASON F�R REVlS10NS:
-l�e-rn ��Y�� �c� � a c-e
Work Class: New� Addition ( } Remodel( ) Repair( ) Demo ( ) Other( )
fWork Type: i��terior�) Exterior O Both O � Does an EHU exist at this location: Yes O No O
Type of Bldg.: Singie-family( ) Two-family( ) Multi-family( ) Commercial,(�} Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fir� laces Existin : Gas A liances Gas Lo s Wood/Pellet Woo Burnin
No/T e of Fire l�ces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wo ' Burn n NOT ALLOWED
Does a Fire Alarm Exist: Yes ) No O Does a Fire Sprinkler System Exist: ' Yes�j) No O
***********,�***n�*�*****«*****,�******************FOR OFFICE USE ONLY��,�****************�*****�***�*�***��********
� Date Received:�' Permit Fee 10 : - PIan;C Fee; 80 : M
! Accepted By:�^ Permit Fee(1'1):- i PIan.0 Fee(81): '
t Outsourced Terms: �
F:\cdev\FORMS1Permits\BuildingUauilding_revision_4-18-2007.doc Page 1 of 1 A/;g12007
..��..�.��s � _ _
,
� �3�o� -��8�
4�4� � � - � 7 ro
ARCHITECT'S SUPPLEMENTAL VAIL'SFRONTDOOR
INSTRUCTION No, A - 030
To: Doug Thompson/ Hyder Construction, If1C. PROJECT NO: ZO693.OH
543 Santa Fe Drive issuE�: 08.1 1.08
Denver, CO 80204 FROM: Randy Hart
303-825-1313 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructions
indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time.
Architect's Supplemental Instruction Title: Building A- Temporary Field Offices in Parking Garage(Lower&Mid Levels)
Reason for Change:
Due to the impending removal of Hyder's Construction Trailers,offce accommodations need to be made for Hyder's remaining
on-site Staff.
Description of Instructions:
Per attached Sketches, temporarily provide Field Office space in Elect. Room A122, Storage A123 and Storage A207-maintaining
Code required clearances at electrical panel and transtormer within Elect. Room A122. Provide make-up air ductwork, fans and
fire/smoke dampers at rated walls as indicated. Balance make-up air to 20cfm per Occupant in each Room. Maintain required exit
access/egress from temporary Offices as indicated. Offices are currently planned to be occupied until the end of December 2008.
Attachments �nd Enclosures:
Architectural Sketches ASK A-047,ASK A-048 &ASK A-049; each dated 08/08/08. ,��ti���'��" E�liance to a��
Subject to inspection and Comp�
relevant Adopted Building andbe approved�des.
Changes in Pla
Date�25--�_._---g�-�
Cnde: 26c53 1 �''�--
�.� i.:k7U1�+ �`���Y�'`{n �
Copy To: ASI File O
BY� � Rick Caudel/VRDC U
� S. Jarvie Worcester/VRDC W
Submit to wn of V . �YES ❑ NO Jay Watson/ABS Engineers U
L.L
LJ._
�
REVIE�'��D B1�
AUG .?_5 ���'�
t
p
42�40 ARCHITECTUREWC � SAFEbuiit Colorado
1621 Eighteenth Street �----�-
Suite 200
Denver,Colorado 80202 The intormation contained in this message is privileged and confidential intended only for the use of the individual(s)or enlity(ies)named
t 303.292.3388 f 303.29231 13 above. If Ihe reader of this message is not the intended recipient,yuu are hereb�notifed thal any dissemination,distribution,or copying of
�awv✓.4?40archicec[ure.com this communicatier,is;trictly prohibited. If you have r�cei�,ied this commur.ica6on in errer,tlzas,-noiify 42/40 Arshiteciur�,In�.irnmediatel�.
!
/GC�^'�'ca/ P�n �� o
a TdnSyofrY]oY /��' �d�rJ �� N�
"�' Rc 'c% Cc�qIGC/Car ncGS,
. . , •: • . ..
R - .< 1. ' - } _•t' S• - .4 '4.I`•'w�••j�
STAIR i • . .� - - . ��.....,_.. : :�
� � ASOt 81.� � ` �. �.
•• • .� , ... .. '•�,y,
' R
�� �� a �d �:�,�.` ..�Fi
.. �9
:Y._.
.5 – – – 5 dl � Gr� ��4 �, ,;•
..1 N.ROOR E ••�- � � JV�A 3 4 � ��r�
57-10 ROOM� '122 � 6 �� 8
r , z .n e,s<� o- ScC/� �A• -� �''
���$ I/b!�tlGf"• Q�.: �5 � `,-t t�^,":� .�
� j
�
I�D �W�VdG� l�(,b �► /1 t!L f7 "' >!'i i��i e_.s'' i''�
3
Cs�.�+ITSK/J�I(w �..Ft°°R 3 : t/ „:Mr"�,.-; ,:,
8153-10 � �a�-0 1 V
��ti.;i,..�..��..�..
„4�/!_�nw!'Vi• STORAG �,�,, \\ . �O*'J,� ;
��� �O» 1 �� A123 � L {.
f]� �� ' 29 �r' '�.
8i�j� �/ � �� ' � �"�.�
/'��"�'j•�G� a niz3 � 2s 2� t \ 28 � � z
�dG�'W ��� � eis —io-
— — ••. � �
�o�� c�mp���'�5, c - -�. -
�f�P�d CM�!l�/ls 2 __. _� _..
I '. � � Ew�Pa �o
\ ur�oF
, 8,53�_0- \ "�"E r�i�Csa�.
A211 AND WALK
- \ \ HTM'y �RC a
MFA IX7NN
� � I9& ,�,0�
'' � � �oao)
:: \
.` \ \
� - - - - ; - �- i -
�_�' Fans s�ad//Gie�v�c�io(n �C � �
Y �i.�s�� �a�iV��• . / V i(/V( 51 52 53 54 �55 55 5
� �,/ a, •-o- ��
���Q�C�dfi�� /n !•° �/ ODI�� a'Pan�o tu�E � \
' � ur�o�
�1��� d� �b 80 8>ao�.,GG����� ,. �`- '�
o�� 4oc�a,n . � o ���.. � �:
-- �%✓ �� drL'vsin � /Cr ��
P ���y � - - 73 74 75 7(
L5 r0 �/ !/����l.��/�. . – – —
� � I
� � � �,: a,sa•—o-
� — — — -- � — — — .
Low/�R G�v� �' Ki�l� , �\\.. ...
,
A/o _._—_.___
1 "' �-D" ;A �_- _ _ :
� � l� - � �� � ; �EVi������_ ��' N b a}'.
r�MPo�a,e�,yYvE�e ST �,� o�F,�E .] --�;; � o
� � U
z5 24 AtJG ��� , � w
' � U
i �
� SAFEbuif� Colorado �
� � Q
^«h«C«°f R«°��' Vail's Front D oor DRAWING NO:A S� A•44�
��� n�a•ncr/Dcvclopc� _REFEAENCE: /T/�'1��?'
Vail Resorrs �AsrA�o3a
Dev;;lopmen�Company ��,�,�
Dcnvcr,Coloradu
rl}•on,Colurad�� D�pyp� �(�
-- _-_- . J .- -
%� 12 ^ I \ �O6 v Y 169.5" I R
av °
�Z F�2KIN �� FlN. FLOOR � N�
E 8166_0 E:fIST.L006E UfH CONDOAIIMUTA Wp�ro SUB I-FlLL
� ICC.BAR ' BUILDING-SO 0 SHADING IMDICA � REMNN
INIAY/ ft �� o I�.STRAINER ARFA TO ft TlP.-RE:D701, RE UC�.
� pp�K D102 FOR SC PE OF DE7dOLI110N
R.4 — � euur�ns
rx�� lA•a49' �"�
�I""�019- �i.RE: 4 _�5� J — I � — '"--��:-_A,.
�. 3,
A �- � � ����! �.�
�J�'I�lUd�jO� ATCHLIN 1 11NE OF IXPANSION JOINf ABOVE � T � ��, �
a o 3� _ ���` �
', L i e,s�-0• I .. �. E. ;�_..:,��� � �
.. F
�� - ------ -- - -- -- . 2'-6' 8167' 43 8167'-1 7 I,�"1 3f�. •1
I a1 �..)
,r�,,. ,,
) Ga�. ,5 ,6 ,� �:.,�.�s,
� EGRE55 BELOW, 876 '-9 3/4" �(n/� uD �s��
SHOWN DASHm 0 GE i �'�/(/ / / �a �
!� n �i
Q$ — �'Z• _ 8 66FL0 � �� �n j .�i� ''�y,"�y F. �, ,.�
ORIDE "�� v -t
8�' � + � � � • lSC SF
� d /� 3
�lP , �, R CI�'!4�
( '� d8,65�_� ,,
0����-D v� CONCREIE CURB
u+o wax
Ex�• L zo �, � 23 24 ,
� W B �� 8166' ' (LSC SF
� ���) � 9'-6' 7-6 MECH
P _ . � WALL RE N105
'�
8166'-0"
O �� �� �
�1 —
3 ,�. � � atss'-s• �
A211 8165'-5 1/4' �. � ���� �
.'� \
\ 10 DRAIN
MECH.GPo � CAILING DOOR � � �
RE NECH. � f—HOUSNG ABOVE I A� c� �/
OWGS.- 102 \ �
\ aC P �'01G�
`•.i. `� e,ss-<3 � �/��j�
;; 8,65�-3 , 4• � , �j= �'M+I q•0 - .
��� a
a D 31�/
�a. �, �.i�: y�
� — b, m. a�
I I 8164'-10 1/2° 1.
1h �• I
8164'-0' 25 2fi
( SPAC� (LSC SPACE)
q x. o
-rN b YECH WALL
OPQJING R
,S MiQ5
D ,
I �` I 7z I
L 5 — _ - -- — >"
. AIJGN FACE&AHCff
����w,� U
OL
I I ` ^ ' � f`� � V
` !��
l`'!io� E✓,�� p RK� � . �
, �t �,
_... .
� l�"=1 0" �•q �o� �,z ..,i, ,. _
� �
�T�N1PQ,e�4R�''f�� cotilsT- �i,F�o oF��c�s .�
��-. . �
,A,�h�tr«<:Fa�,.��.<� V�1��S FYOI1� �00�' �w,wtNC r�o:�SK A•�8 �
�.24c� A/��a� �
Oo•ncr/Derclnpc� Rg���
�
uc111 ReSOiCS S�E-A O
��:/'7����
Development Company �/�f�.
Ucnver,Col��rado 1rnn,Colurado
DR/+WN BY:`^��
f . . � .
I
U.8 — — — — -- — � _
RAILMG ON SfONE CAP __ ___
RE:IANDSCAPE � �,
�".« '
....y .-...,,�`..
,�r � Q� ��;�,� �„�
���i��\ NEW WALL AND .�� �`t� 3 �.
r y FIEVATOR N.I.C. ti ��
/�- - - - - - - - - - - - - — '� ���F_-� S.�
IIC--I E. � ��,.�
f I�_� - EUNUST A1R
T.8 — — — — — �� +^+� ;�;e"'?
ii r— — ,
�I � RE:NECH.FO - '
STONE VENEER � : � IXW�US(S FM!" �::,cr.<".�.��.a _:�i �
REIAINING IXWWST P1R OPENING �� � "�'�._�' .
W� I RE M104 �
I � ; r3
r+EUU waus ,e�.�, =c"<,.
H.i.c. .y�,� , § i.
�� I r '/Z. �, `_'_/-�/ �.
" o.l'� � 4 �
3' �- �oo
SfONE ��f�J� �_Y �-B�
A' � ��Gif/r'� 10'-0' AREA�RNN� I
� IYP.OF 5
S.5 — '
•� 8167'-1 3 " , M1AE H. ROOM �OS �
/ `Id . AZO6 OS 3 LOADING 3
" �P � DWJN�� �, I 3 T.O. OCK LEVQER I C OPEMNGS A
,'� � �O%� �2 A206 8169-6 I i�0 ACCESS NEW
y. . / X
•�rV.�./Ir(�j1 .r�' � P 6 �� N. FLOOR OW
w�� ��• `,,�i� � 166.0 WSl.LODGE Mi CONDOAIINIUN W�TQ
f�} eQ/� �� � LOADWG DOCK �P ICC.flAR ' BUIIDING-SO D SHADING INDICA REMAIN
(�//"I7J(J �� / EN1Ry/IXfT � � RESIRAINFR PFFA TD R N,IYP.-RE DI01,
': DOCK
�R.4 •s� �\ - !/ � _ BUMPERS
� LOADING
\ / �• 1 0 \.� i / \�. DOCN ' -
MATCHLINE ���:� ' �� � �'� _c5�SrL� �
RE: A105 �� / �l�ip�y� —
':. - ' �nd•
R oi �'�. L�••• ^I Bt66',' � E OF IXPANSION J�]IM ABWE, (' I
. • :.
% � RE DEfA1L 14/A570'S'
` ��G,� �• ------ 2'-6" 8767' 4 3 8167'-1 7/2'
� S�s ;r+c �.,�.\�� ` — --- �„ c�P;ral "h
0" �o
�
D� � C 15 6 17 �
,B�law�.ke,4SX B �� •,.w„ ,� .�
E�p6S gaqy. 816 '-9 3/4
/� SHOWN 0.4SHm � A � � •i
'j�► /1(/� �,� (�/� � /� _ ' FlN. OOR
• .
Q.5 i�y� ei a �
OftIOE
�1G• 8 n-�o�K �,2 ---
Vrir►eav dGa�C,Ew�Or , , �� f
\ •k 8165'-7 7 4"�
�r�u�d� ��rn�orary�r�/�e. 5.0 ��,.��,� ,�. � U
24 2.
/�?io• L�v�c. ��Ki�1 �u� l� ���� � �
_ i�
� M= / /1 RE CML OWllNNGS FOR iUNNE1 RWUWAY PROFILFS,AND WISTRUC110N DANN 1. ALL WORK F01
��� �—d .�.'.!t Coloradc� 'PART OF iH15
R�:�/����A . HE��M�WB �
--""' -- - DOORS W/LOC
/ r�.Jc��,�.. 'MRL
. ��iMPOR�-1•-Y I I Y�� ���'�.!•i.� ? _��=P?C T4F
�;GEPoOR. nNC
�«h«Y<<<>rR,_��.�� Vail's Front Doo� o�W�N� �0:�5� A'0¢�
�2�� O+�ncr/Dcvdoper , RffERENCE�/j���A
Vall ReSOrtS �E" O
De��eloprrien�Company ��sl AR'O3�j
llcm�cr,Coloradu rlcoq Colutado O�� v�Ov
DRAWN 8Y:
�O! _
C O N S U L T A N T��� 1 N G
January 9, 2006
Building Safety & Inspection Services
Town of Vail
Vail, Colorado
Attn: Electrical Plan Reviewer
Re: Vail's Front Door—Buildings A, C & D—Garage, Ski Club & Skier Services
Subj: IECC Lighting Compliance
To whom it may concern:
Buildings A, C and D are all served from a common electrical service. The IECC Lighting Compliance
calculations far these buildings were prepared in three parts to allow for a streamlined review process.
Please see the attached sets of calculations for details of each building.
Buildings A and D are shown to be in compliance. Building C is shown as not in compliance. When all
three buildings are looked at together they comply:
M Buildin� Allowed Watts Actual Watts
"A" 17,461 16,702
"C" 16,071 18,797
"D" 34,940 32,817
Total 68,472 68,316
Lighting design for this electrical service Complies with IECC 805.
Should there be any questions, please contact us.
Sincerely, � ��� �
Consultants, Inc.
�
�� � �'
�✓�/
'j'�� Ron E. Bourgault,P.E.
Partner
[REB/mwr]
P:�2001-134-03�ADM[1V�Etec_A\Corr\Mwr-Ltrv2006-I-9 Bld�A-C-D[ECC Compliance Letter.Doc
1530 16TH STREET,SUITE 400 _, _
DENVER, COLORADO 80202
303-623-6200 FAX 623-8435
Permit Number
Lighting Compliance Certificate Checked By/Date
2003 IECC
COMcheck-EZSoftware Version 3.0 Release 1
Data filename:P:\2001-134-03�ADMIN�EIec_A\Schedules�Building A-Garage�Bldg-A-Parking-mtv.cck
\\\\\ � ���oa�e�Mri�vi��i
Section 1: Project Information \\�����` � ��m� ��o�,%.,,,��
` !7 0 (���R���A
Project Name: VaiPs Front Door =v '' "��:���
Building A-Parking : 6� �o '
Designer/Contractor: ABS Consultants Inc. 'p� ���
Document Author: Marcus Vahling .� �.',���0
C, ig���o�eQ°��L+!��';'�1,'^�
Section 2: General Information �,`,'%r��`q�°�'��`�'��
.�,: �.}^•.5i��0
JAN �1 0 2006
Building Use Description by: Whole Building Type
Project Type: New Construction
Building Tvne Floor Area
Parking Garage 92279
Section 3: Requirements Checklist
Bldg. �
Dept. �
Use �
[ ] � Interior Lighting
� 1. Total actual watts must be less than or equal to total allowed watts
� Allowed Watts Actual Watts Complies(Y/N)
� 27684 27624 YES
�
� Exterior Lighting
[ J � 2. Efficacy greater than 45 lumens/W
� Exceptions
� Specialized lighting highlighting features of historic buildings; signage;safety or security lighting;
� low-voltage landscape lighting.
�
� Controls,Switching,and Wiring
[ ] � 3. Independent controls for each space(switch/occupancy sensor).
� Exception: Areas that must be continuously illuminated.
[ ] � 4. Master switch at entry to hoteUmotel guest room.
[ ] � 5. Individual dwelling units separately metered.
[ ] � 6. Each space provided with a manual control to provide uniform light reduction capability.
� Exceptioris:
� Only one luminaire in space;An occupant-sensing device controls the area;
� The area is a corridor,storeroom,restroom,ar lobby;Areas that must be continuously illuminated;
� Areas greater than 250 sq.ft;Areas that use less than 0.6 Watts/sq.ft.
[ ] � 7. Photocell/astronomical time switch on exterior lights.
� Exceptions: Areas requiring lighting during daylight hours
[ ] � 8. Tandem wired one-lamp and three-lamp ballasted luminaires.
� Exceptions
� Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans,specifications and other
calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003
IECC,Chapter S,requirements in COM check-EZ Version 3.0 Release 1 and to comply with the mandatory requirements
in the Requirements Checklist.
MAru�� V�K�,u�� . .o _
Principal Lighting Designer-Name ig ture Date
Lighting Application Worksheet
2003 IECC
COMcheck-EZ Software Version 3.0 Release 1
Section 1: Allowed Lighting Power Calculation
A B C D
Total
Floor Allowed Allowed
Area Watts Watts
Buildin�Tvbe (ft21 (watts/ft21 B x Cl
Parking Garage 92279 0.3 27684
Total Allowed Watts= 27684
Section 2: Actual Lighting Power Calculation
A B C D E F
Fixture Fixture Description/ Lamps/ #of Fixture
ID Lam_p Description/Wattage Per Lamp/Ballast Fixture Fix r Watt. D( x El
A GARAGE FIXTURE/Metal Halide 150W/Electronic 1 49 170 8330
B GARAGE CUT OFF/Metal Halide 150W/Electronic 1 37 170 6290
C LOADING/Metal Halide 175W/Electronic 1 29 232 6728
D LOADING/Metal Halide 175W/Electronic 1 4 232 928
E TUNNEL/Metal Halide 150W/Electronic 1 26 170 4420
WP TUNNEL/Metal Halide 175W/Electronic 1 4 232 928
Total Actual Watts= 27624
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies.
Total Allowed Watts= 27684
Total Actual Watts= 27624
Project Compliance= 60
Lighting PASSES: Design 0.2%better than code
Permit Number
Lighting Compliance Certificate Checked By/Date
2003 IECC
COMcheck-EZSoftware Version 3.0 Release 1
Data filename:P:�2001-134-03�ADMIN�EIec_A\Schedules�Building A-Garage�Bldg-A-CRS-mtv.cc
i`\`�11R ilIIIIL'ty//�
Section 1: Project Information \�����``�� ,R��a��;�,,�/
� d p �V�c•:P�f
Project Name: Vail's Front Door ; '� 's'�u`�';
Building A-Conidor,Storage,Of�ce,Industrial - ' 2 �3 `-a =:
. �-+�
. .-�;
Designer/Contractor: ABS Consultants Inc. ' ;��
Document Author: Marcus Vahling ;��".`
.
�a••...om°'4"�
Section 2: General Information ���`��'�� �" '
%,,,.,
�IAN i 0 2oaf�
Building Use Description by: Activity Type
Project Type: New Construction
Activitv Tvpe(sl Floor Area
Corridor,Restroom,Support Area 5936
Storage,Industrial and Commercial 2334
Office 451
Industrial Work,<20 ft Ceiling Height 5835
Lobby-Other 2118
Section 3: Requirements Checklist
Bldg. �
Dept. �
Use �
[ ] � Interior Lighting
� 1. Total actual watts must be less than or equal to total allowed watts
� Allowed Watts Actual Watts Complies(Y/N)
� 17461 16702 YES
�
� Exterior Lighting
[ ] � 2. Efficacy greater than 45 lumens/W
� Exceptions:
� Specialized lighting highlighting features of historic buildings;signage;safety or security lighting;
� low-voltage landscape lighting.
�
� Controls,Switching,and Wiring
[ ] � 3. Independent controls for each space(switch/occupancy sensor).
� Exception: Areas that must be continuously illuminated.
[ ] � 4. Master switch at entry to hotel/motel guest room.
[ ] � 5. Individual dweiling units separately metered.
[ ] � 6. Each space provided with a manual control to provide uniform light reduction capability.
� Exceptions:
� Only one luminaire in space;An occupant-sensing device controls the area;
� The area is a corridor,storeroom,restroom,or lobby;Areas that must be continuously illuminated;
� Areas greater than 250 sq.ft;Areas that use less than 0.6 Watts/sq.ft.
[ ] � 7. Photocell/astronomical time switch on exterior lights.
� Exceptions: Areas requiring lighting during daylight hours
[ ] � 8. Tandem wired one-lamp and three-lamp ballasted luminaires.
� Exceptions
� Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans,specifications and other
calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003
IECC,Chapter 8,requirements in COM check-EZ Version 3.0 Release 1 and to comply with the mandatory requirements
in the Requirements Checklist.
M���s V�,H��u�� � �o
Principal Lighting Designer- amN e Sig ture Date
Lighting Application Worksheet
2003 IECC
COMcheck-EZ Software Version 3.0 Release 1
Section 1: Allowed Lighting Power Calculation
p B C D
Total
Floor Allowed Allowed
Area Watts Watts
Area Categorv (ft21 (watts/ft21 B x Cl
Corridor,Restroom,Support Area 5936 0.9 5342
Storage,Industrial and Commercial 2334 0.8 1867
Office 451 i.l 496
Industrial Wark,<20 ft Ceiling Height 5835 L2 7002
Lobby-Other 2118 1.3 2753
Total Allowed Watts= 17461
5ection 2: Actual Lighting Power Calculation
�, B C D E F
Fixture Fixture Description/ Lamps/ #of Fixture
ID Lamn Description/Wattage Per Lamp/Ballast Fixture Fixtures Watt. D( x E1
B GARAGE CUT OFF/Metal Halide 150W/Electronic 1 2 170 340
C LOADING/Metal Halide 175W/Electronic 1 7 232 1624
CV COVE FIXTURE/28W-TS/Electronic 1 37 30 1110
D LOADING/Metal Halide 175W/Electronic 1 6 232 1392
D1 VALET DOWNLIGHT/Metal Halide SOW/Electronic 1 12 60 720
DL DOCK LIGHT/Incandescent 250W 1 8 250 2000
EP PIT LIGHT/Incandescent 100W 1 2 100 200
F STAIR/48"T8 32W/Electronic 2 8 64 512
G INDUSTRIAL WRAP/48"T8 32W/Electronic 3 28 96 2688
J STRIP/48"T8 32W/Electronic 2 1 64 64
K TANDEM STRIP/48"T8 32W/Electronic 4 44 128 5632
SC DECORATNE SCONCE/Incandescent 60W 1 7 60 420
Total Actual Watts= 16702
Section 3: Compliance Calculation
If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero,the building complies.
Total Allowed Watts= 17461 "'— --
Total Actual Watts= 16702
Project Compliance= 759
Lighting PASSES: Design 4%better than code
Permit Number
Lighting Compliance Certificate � ch�kea Byi�ate
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a
Data filename: P:A2001-134-03\ADMIN�Elec A\Schedules\Building C - Ski Club\Bldg-GSkiClub.cck
,;�,;t,l`��'�i?11!{I//� //
Section 1: ProjectInformation ''''''�° "' '�� ��'
�� ;� s
`,�� ��o� � o,,�� %,,,
� �cw �. •� '�i
Project Name: Vail's Front Door ���° �°��'
= O SJ R �
° �'���
Building C - Ski Club = ° � 3 ,_r`..�; �
Designer/Contractor: ABS Consultants, Inc. _ ��`
Document Author: Michael Rogers, LC � ��`��;
i •������e���e���\`��
Section 2: General Information ��ii�o������A�„�������
Building Use Description by: Activity Type JAN 1 0 200G
Project Type: New Construction
Activitv Tvae(sl Floor Area
Corridor, Restroom, Support Area 3599
Storage, Industrial and Commercial 2447
Kitchen 180
Lobby -Other 1087
Convention, Conference or Meeting Center 1999
Office 235
Exercise Center 3953
S ection 3: Requirements Checklist
Bldg. �
Dept. �
Use �
� Interior Lighting
[ ] � 1. Tota1 ac�tual watts must be less than or equal to total allowed watts
� Allowed Watts Actual Watts Complies(Y/N) s�,�i g�f��� ��
� 16071 18797 NO
�
� Exterior Lighting
[ ] � 2. Efficacy greater than 45 lumens/W
� Exceptions:
� Specialized lighting highlighting features ofhistoric buildings; signage; safety or security lighting;
� low-voltage landscape lighting.
�
� Controls, Switching, and Wiring
[ ] � 3. Independent controls �r each space(switch/occupancy sensor).
� Exception: Areas that must be continuously illuminated.
[ ] � 4. Master switch at entry to hotel/motel guest room.
[ ] � 5. Individual dwelling units separately metered.
[ ] � 6. Each space provided with a manual control to provide unifarm light reduction capability.
� Exceptions:
� Only one luminaire in space; An occupant-sensing device controls the area;
� The area is a corridar, storeroom, restroom, or lobby; Areas that must be continuously illuminated;
� Areas that use less than 0.6 Watts/sq.$.
[ ] � 7. Automatic lighting shutoffcontrol in buildings lar�er than 5,000 sq.$.
[ ] � 8. Photocell/astronomical tiine switch on exterior lights.
� E.rceptions: Areas requiring lighting during daylight hours
[ ] � 9. Tandem wired one-lamp and three-lamp ballasted luminaires.
� Exceptions:
� Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair.
Lighting Application Worksheet
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a
S ection 1: Allowed Lighting Power Calculation
A B C D
T otal
Floor Allowed Allowed
Area Watts Watts
Area CateQorv ($21 (watts/tf21 B x Cl
Corridor, Restroom, Support Area 3599 0.9 3239
Storage, Industrial and Commercial 2447 0.8 1958
Kitchen 180 1.2 216
Lobby-Other 1087 1.3 1413
Allowance: Decorative/ Fix. ID: LTG9 52(a) 1 52(b�
Allowance: Decorative/ Fix. ID: LTGS 240�a) 1 240(b)
Allowance: Decorative/Fix. ID: LTG4 795(a) 1 480�b)
Convention, Conference or Meeting Center 1999 1.3 2599
Allowance: Decorative/ Fix. ID: LTG3 150(a) 1 150(b)
Allowance: Decorative/Fix. ID: LTG2 108(a) 1 108�b)
Allowance: Decorative/Fix. ID: LTG1 1684(a� 1 1500(b�
O�ce 235 1.1 258
Exercise Center 3953 0.9 3558
Allowance: Decorative/Fix. ID: LTG8 1680(a� 1 300�b�
(a)Area claimed�st not exceed the illuminated area perrnitted for this allowance type.
(b)Allowance is(B x C)or the actual wattage ofthe fixtures given in Section 2,whichever is less.
Total Allowed Watts = 16071
Section 2: Actual Lighting Power Calculation
A B C D E F
Fixture Fixture Description/ Lamps/ # of Fixture
ID Lamp Description/Wattage Per Lamp/Ballast Fixture Fixtures Watt. (D x EL
A1 6" DOWNLIGHT /Triple 4-pin 42W /Electronic 1 37 35 1295
A4 4" DOWNLIGHT /Triple 4-pin 18W /Electronic 1 4 18 72
AS 7" DOWNLIGHT / Triple 4-pin 42W /Electronic 1 3 37 l ll
A6 HID FLOODLIGHT /Metal Halide 70W / Electronic 1 14 85 1190
A7 MR16 LOW VOLTAGE/ 37W MR16 1 54 32 1728
A8 4" APERATURE MR16/ 37W MR16 1 15 37 555
A9 6" WALL WASHER/Triple 4-pin 32W /Electronic 1 8 35 280
A10 CF CYLINDER/Triple 4-pin 32W / Electronic 1 6 35 210
B 1 6" SHOWERLIGHT /Twin Tube 24/26/27W /Electronic 1 2 30 60
D1 6" IND WALL WASHER/ Incandescent 75W 1 8 35 280
F1 4' UPLIGHT /48" T8 32W /Electronic 1 1 32 32
F2 3' UPLIGHT / 36" T8 25W /Electronic 1 2 25 50
F3 2x4 TROFFER/48" T8 32W / Electronic 3 3 96 288
F4 4' STRIP /48" T8 32W /Electronic 2 17 64 1088
F8 8' TANDEM STRIP /48" T8 32W / Electronic 4 2 128 256
G 4' WRAP /48" T8 32W / Electronic 2 33 64 2112
L LOCKER UPLIGHT /48" T8 32W / Electronic 1 149 32 4768
L1 LOCKER UPLIGHT /48" T8 32W / Electronic 1 22 25 550
LTG1 20 LAMP -25W IND DECO FIXTURE/ Incandescent 25W 1 3 500 1500
LTG2 BAR PENDANT / Quad 2-pin 18W / Electronic 1 6 18 108
LTG3 GREAT DECO FIXTURE/ Incandescent 25W 2 3 50 150
LTG4 6 LAMP -40W IND DECO FIXTURE/Incandescent 40W 6 2 240 480
LTGS ELEVATOR LOBBY/Incandescent 40W 3 2 120 240
LTG6 DECOR RR SCONCE/ Quad 2-pin 13W /Electronic 1 6 13 78
LTG7 LOCKER RR SCONCE/ Quad 2-pin 13W /Electronic 2 2 26 52
LTG8 LOCKER ROOM CHANDELIER/ Incandescent 75W 7 4 75 300
LTG9 CORRIDOR WALL SCONCE/ Quad 2-pin 13W /Electronic 1 4 13 52
LTG10 LOCKER RR PENDANT / Twin Tube 24/26/27W /Electronic 1 4 27 108
S1 VANITY WALL SCONCE/ Incandescent 60W 2 2 120 240
S2 STAIR LANDING SCONCE/ 48" T8 32W / Electronic 2 6 64 384
S3 ELEVATOR PIT /Incandescent 60W 1 3 60 180
Total Actual Watts = 18797
Section 3: Compliance Calculation
Ifthe Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies.
Total Allowed Watts= 16071
Total Actual Watts = 18797
Project Compliance= -2726
Lighting FAILS: Design 17%worse than code
Permit Number
Lighting Compliance Certificate Checked By/Date
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a
Data filename: P:\2001-134-03\ADMIN�EIec A\Schedules\Building D -Skier Services\Bldg-D-SkiService.cck
Section 1: Project Information `�������;'�' �°,''�`,v;,,
�0��� '� ` � �", ���
`��'�'�°°•°.B `• e��:
A � %,
Project Name: Vail's Front Door ��m�O �,° �!_
Building D -Skier Services = •�Q o� c 9G�;
Designer/Contractar: ABS Consultants, Inc. = .O QtJ� °'��_
Document Author: Michael Rogers, LC � :�+�
� ��\��
Section 2: General Information �°'��i,,����c�'%�`►�,i�,�.����o`''��
Building Use Description by: Activity Type .J��t � U `006
Project Type: New Construction
Activitv Tvoe(sl Floor Area
Retail Sales, Wholesale Showroom 6107
Restaurant 2919
Lobby-Other 438
Office 2080
Comdor, Restroom, Support Area 11536
Storage, Industrial and Commercial 4068
Section 3: Requirements Checklist
Bld�. �
Dept. �
Use �
� Interior Lighting
[ ] � 1. Total actual watts must be less than or equal to total allowed watts
� Allowed Watts Actual Watts Complies(Y/N)
� 34940 32817 YES
(
� Exterior Lighting
[ ] � 2. Efficacy greater than 45 lumens/W
� Exceptions:
� Specialized lighting highlighting features ofhistoric buildings; signage; safety or security lighting;
� low-voltage landscape lighting.
�
� Controls, Switching, and Wiring
[ ] � 3. Independent controls �r each space(switch/occupancy sensor).
� Exception: Areas that must be continuously illuminated.
[ ] � 4. Master switch at entry to hotel/motel guest room.
[ ] � 5. Individual dwelling units separately metered.
[ ] � 6. Each space provided with a manual control to provide uniform light reduction capability.
� Exceptions:
� Only one luminaire in space; An occupant-sensing device controls the area;
� The area is a corridor, storeroom, restroom, or lobby; Areas that must be continuously illuminated;
� Areas that use less than 0.6 Watts/sq.$.
[ ] � 7. Automatic lighting shutoffcontrol in buildings larger than 5,000 sq.$.
[ ] � 8. Photocell/astronomical time switch on exterior lights.
� Exceptions: Areas requiring lighting during daylight hours
[ ] � 9. Tandem wired one-lamp and three-lamp ballasted luminaires.
� Exceptions:
� Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans, specifications and other
calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003
IECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2a and to comply with the mandatory require�nents
in the Requirements Checklist.
!"l�u�i�u �G,�r�S. L� ��/ � 1- �'-0�
Principal Lighting Designer-Name Signature Date
Lighting Application Worksheet
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a
Section 1: Allowed Lighting Power Calculation
p B C D
T otal
Floor Allowed Allowed
Area Watts Watts
Area CateQorv (ff21 (watts/$21 B x Cl
Retail Sales, Wholesale Showroom 6107 1.7 10382
Allowance: Merchandise Display/Fix. ID: T 1 2580(a) 1.6 2580(b)
Allowance: Merchandise Display/Fix. ID: DL-205 200(a) 1.6 200(b)
Restaurant 2919 0.9 2627
Allowance: Decorative/ Fix. ID: DL-211 160(a) 1 160(b)
Allowance: Decorative/Fix. ID: DL-210 80(a) 1 80(b)
Allowance: Decorative/Fix. ID: DL-207 539(a) 1 539(b)
Allowance: Decorative/Fix. ID: DL-204 640(a) 1 640(b)
Allowance: Decorative/Fix. ID: DL-203 800(a) 1 800(b)
Lobby -Other 438 1.3 569
Allowance: Decorative/Fix. ID: DL-206 238�a) 1 238(b�
Allowance: Decorative/ Fix. ID: DL-201 200�a) 1 200(b)
Office 2080 1.1 2288
Corridor, Restroom, Support Area 11536 0.9 10382
Storage, Industrial and Commercial 4063 0.8 3254
(a)Area claimed iraist not exceed the illuminated area pernritted for this allowance type.
(b)Allowance is(B x C)or the actual wattage ofthe fixtures given in Section 2,whichever is less.
Total Allowed Watts = 34940
Section 2: Actual Lighting Power Calculation
p B C D E F
Fixture Fixture Description/ Lamps/ #of Fixture
ID Lam�Description/Wattaee Per Lamp/Ballast Fixture Fixtures Watt. x E
A1 6" DOWNLIGHT /Triple 4-pin 32W / Electronic 1 27 35 945
A2 6" SURFACE/ Triple 4-pin 32W / Electronic 1 30 35 1050
A3 9" SURFACE/ Triple 4-pin 42W / Electronic 2 18 90 1620
AS LOW VOLT MR16/ 37W MR16/Electronic 1 114 37 4218
A6 QUARTZ FLOOD/ Incandescent 150W 1 26 150 3900
A7 6" DOWNLIGHT /Triple 4-pin 32W /Electronic 1 7 35 245
A8 4° LOW VOLT MR16/ 37W MR16/ Electronic 1 11 37 407
A9 6" DOWNLIGHT / Triple 4-pin 32W / Electronic 1 3 35 105
D 4' WRAP /48" T8 32W /Electronic 2 9 64 576
DL-201 CHANDELIER/ Incandescent 2�W 8 1 200 200
DL-202 CHANDELIER/Incandescent 25W 6 2 150 300
DL-203 CHANDELIER /Incandescent 40W 1 2 400 800
DL-204 CHANDELIER/ Incandescent 40W 8 2 640 1280
DL-205 WALL SCONCE/Incandescent 40W 1 5 40 200
DL-206 PENDANT / (1�40W & (1)37W 2 4 77 308
DL-207 PENDANT / (1}40W & (1)37W 2 7 77 539
DL-209 WALL SCONCE/Incandescent 40W 1 40 40 1600
DL-210 WALL SCONCE/Incandescent 40W 1 2 40 80
DL-211 WALL SCONCE/Incandescent 40W 1 4 40 160
DL-212 WALL SCONCE/Incandescent 25W 2 4 50 200
F4 4' STRIP /48" T8 32W /Electronic 2 21 64 1344
F8 8' STRIP /48" T8 32W / Electronic 4 1 128 128
G 2x4 TROFFER/48" T8 32W / Electronic 3 34 96 3264
G1 2x4 TROFFER/48" T8 32W / Electronic 3 8 96 768
G2 2x4 TROFFER/48" T8 32W / Electronic 3 4 96 384
G3 2x2 TROFFER/ 24" T8 17W / Electronic 3 8 51 408
J SINGLE LAMP STRIP /48" T8 32W /Electronic 1 5 32 160
K 8' TANDEM SINGLE/48" T8 32W / Electronic 2 72 64 4608
M 4' WALL BRACKET /48" T8 32W /Electronic 2 5 64 320
S3 ELEV PIT / Incandescent 60W 1 2 60 120
T 1 TRACK/ 30w per foot 1 86 30 2580
Tota1 Actual Watts= 32817
S ection 3: Compliance Calculation
Ifthe Total Allowed Watts minus the Total ActTCal Watts is greater than or equal to zero, the building complies.
Tota1 Allowed Watts= 34940
Total Actual Watts= 32817
Project Compliance= 2123
Lighting PASSFS: Design 6%better than code
Permit Number
Lighting Compliance Certi�cate cne�kea ByiDace
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a ������WIIIW ���
Data filename: P:\20F90D�1\ADMIN�EIec A\SCHEDU�I\BUILDI�l\BLDG-B�I.CCK ������OQ R �' ��,���
_ \``�oe• O��p� . i 'f�
/
S ection 1: Project Information _v�=Q�� �=
_ ° � �. �
Project Name: Vail's Front Door � � ;�a
Building B - Spa � �:.`�.,��
Designer/Contractor: ABS Consultants, Inc. F •....••'��`.`�
Document Author: Michael Rogers, LC ����� i;,,,,,���'��°�``'°`�
Section 2: General Information �1AN 1 0 ZO��
Building Use Description by: Activity Type
Project Type: New Construction
Activitv Tvne(sl Floor Area
Corridor, Restroom, Support Area 7237
Office 468
Hotel Function 5457
Lobby-Other 1073
Exercise Center 2416
Retail Sales, Wholesale Showroom 578
Section 3: Requirements Checklist
Bldg. �
Dept. �
Use �
� Interior Lighting
[ ] � 1. Total actual watts must be less than or equal to total allowed watts
� Allowed Watts Actual Watts Complies(Y/N)
� 23144 22820 YES
�
� Exterior Lighting
[ ] � 2. Efficacy greater than 45 lumens/W
� Exceptions:
� Specialized lighting highlighting features ofhistoric buildings; signage; sa�ty or security lighting;
� low-voltage landscape lighting.
...
�
� Controls, Switching, and Wiring
[ ] � 3. Independent controls �r each space(switch/occupancy sensor).
� Exception: Areas that must be continuously illuminated.
[ ] � 4. Master switch at entry to hotel/motel guest room.
[ ] � 5. Individual dwelling units separately metered.
[ -] � 6. Each space provided with a manual control to provide unifarm light reduction capability.
� Exceptions:
� Only one luminaire in space; An occupant-sensing device controls the area;
� The area is a comdor, storeroom, restroom, or lobby; Areas that must be continuously illuminated;
� Areas that use less than 0.6 Watts/sq.$.
[ ] � 7. Automatic lighting shutoffcontrol in buildings lazger than 5,000 sq.$.
[ ] � 8. Photocell/astronomical time switch on exterior lights.
� Exceptions: Areas requiring lighting during daylight hours
[ ] � 9. Tandem wired one-lamp and three-lamp ballasted luminaires.
� Exceptions:
� Electronic high-frequency ballasts; Luminaires on emergency circuits or with no available pair.
Section 4: Compliance Statement
The proposed lighting design represented in this document is consistent with the building plans, specifications and other
calculations submitted with this peimit application. The proposed lighting syste�n has been designed to meet the 2003
IECC, Chapter 8, requirements in COMcheck-EZ Version 3.0 Release 2a and to comply with the mandatory requirements
in the Requirements Checklist.
�"�«.K�4rr.� /�v��i�S f G� ��t/• a� 1- �!�OCo
Principal Lighting Designer-Name Signature Date
Lighting Application Worksheet
2003 IECC
COMcheck-EZ So$ware Version 3.0 Release 2a
Section 1: Allowed Lighting Power Calculation
�, B C D
T otal
Floor Allowed Allowed
Area W atts W atts
Area Cate�orv (i�2) (watts/$21 B x Cl
Corridor, Restroom, Support Area 7237 0.9 6513
Office 468 1.1 515
Hotel Function 5457 1.3 7094
Allowance: Decorative/Fix. ID: DL-117 96(a) 1 96(b)
Allowance: Decorative/Fix. ID: DL-115 1271(a� 1 1271(b)
Allowance: Decorative/Fix. ID: DL-113, DL-ll3EM 72(a) 1 72(b)
Allowance: Decorative/Fix. ID: DL-112 150(a> 1 150�6)
Allowance: Decorative/Fix. ID: DL-ll 1 416(a) 1 416(b)
Allowance: Decorative/Fix. ID: DL-108 72(a) 1 72(b)
Allowance: Decorative/Fix. ID: DL-107 200(a) 1 200(b)
Allowance: Decorative/Fix. ID: DL-106 160(a) 1 160�b�
Lobby-Other 1073 1.3 1395
Allowance: Decorative/Fix. ID: DL-116 80(a) 1 80(b)
Allowance: Decorative/Fix. ID: DL-109 300(a) 1 300(b)
Allowance: Decorative/Fix. ID: DL-103 240(a) 1 240(b)
Allowance: Decorative/Fix. ID: DL-101 180(a) 1 180(b)
Allowance: Decorative/Fix. ID: DL-100 225(a� 1 225(b�
Exercise Center 2416 0.9 2174
Allowance: Decorative/Fix. ID: DL-105 576(a) 1 576(b)
Retail Sales, Wholesale Showroom 578 1.7 983
Allowance: Merchandise Display/Fix. ID: F8 432(a) 1.6 432(bj
(a)Area claimed must not exceed the illuminated area pernritted far this allowance type.
(b)Allowance is(B x C)or the actual wattage ofthe fiactures given in Section 2,whichever is less.
Total Allowed Watts = 23144
Section 2: Actual Lighting Power Calculation
A B C D E F
Fixture Fixture Description/ Lamps/ #of Fixture
ID Lamp Description/Wattage Per Lamp/ Ballast Fixture Fixtures Watt. x E
--�... __
A2,A2EM 6" DOWNLIGHT / Triple 4-pin 26W /Electronic 1 23 26 598
A3 LOW VOLTAGE/MR16 1 29 37 1073
A4 6" DOWNLIGHT / Triple 4-pin 42W /Electronic 1 2 42 84
AS 4" DOWNLIGHT /Triple 4-pin 26W / Electronic 1 18 31 558
B 1 SHOWER/Incandescent 75W 1 11 75 825
B2 STEAM RM/ 37W FLOOD 1 10 37 370
C1,C2, C LOW VOLTAGE ACCENT / 37W 1 38 37 1406
DL-100 CHANDELIER/Incandescent 2�W 1 1 225 225
DL-101 PENDANT /Incandescent 25W 3 1 180 180
DL-103 SCONCE/ Incandescent 40W 1 6 40 240
DL-104 FITNESS FLUORESCENT / Quad 2-pin 26W /Electronic 4 14 106 1484
DL-105 WALL SCONCE/Quad 2-pin 18W / Electronic 2 16 36 576
DL-106 LOCKER RM SCONCE/Incandescent 40W 1 4 40 160
DL-107 SPA SCONCE/Incandescent 25W 4 2 100 200
DL-108 SPA CEILING/Quad 2-pin 18W /Electronic 2 2 36 72
DL-109 SPA CHANDELIER/Incandescent 60W 5 1 300 300
DL-111 LOCKER RM FLUORESCENT /Twin Tube 24/26/27W /Electronic 1 16 26 416
DL-112 LOUNGE WALL SCONCE/ Incandescent 25W 3 2 75 150
DL-113, LOBBY CEILING/Twin Tube 18W / Magnetic 4 16 72 1152
DL-115 TREATMENT RM/ Quad 2-pin 26W /Electronic 1 41 31 1271
DL-116 RETAIL PENDANT / Incandescent 40W 1 2 40 80
DL-117 LADIES LOLTNGE/Triple 4-pin 32W /Electronic 3 1 96 96
F1, F1EM 46" SINGLE LAMP STRIP /28W TS /Electronic 1 14 36 504
F2, F2EM 46" SINGLE LAMP STRIP /28W TS /Electronic 1 8 36 288
F3 SINGLE STRIP /48" T8 32W / Elec,-tronic 1 12 41 492
F4 46" SINGLE LAMP STRIP / 28W TS /Electronic 1 8 36 288
FS 8' STRIP / SSW TS / Electronic 2 2 132 264
F6 4' STRIP /Other/Electronic 1 2 70 140
F7 CEILING WASH/Metal Halide 70W /Electronic 1 6 82 492
F8 RETAII. CASE FIXTURE/ 28W TS /Electronic 1 12 36 432
G2 UPLIGHT / 37W FLOOD 1 10 37 370
J4 STRIP /48" T8 32W / Electronic 2 3 64 192
J8, J8EM 8' TANDEM/48" T8 32W /Electronic 4 10 128 1280
K, KEM 4' WRAP /48" T8 32W / Electronic 2 11 64 704
K1 4' UPLIGHT /48" T8 32W / Electronic 1 7 32 224
K2 3' UPLIGHT / 36" T8 25W / Electronic 1 6 25 150
MEM STAIR WALL BRACKET /48" T8 32W /Electronic 2 1 64 64
N PIT LIGHT / Incandescent 60W 1 3 60 180
R, REM 2x4 TROFFER/48" T8 32W / Electronic 3 13 96 1248
R1, R1EM 2x4 TROFFER/48"T8 32W /Electronic 2 49 64 3136
R2 2x4 INDIRECT /48"T8 32W /Electronic 3 1 96 96
T UNDERCONTER/24V lOW 8 8 80 640
T 1 UNDERCONTER/24V lOW 4 3 40 120
Total Actual Watts = 22820
S ection 3: Compliance Calculation
Ifthe Total Allowed Watts minus the Total Acti�al Watts is greater than or equal to zero, the building complies.
Total Allowed Watts = 23144
Total Actual Watts = 22820
Project Compliance= 324
T Lighting PASSFS: Design 1%better than code
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT Permit #: A07-0098 ��j1� �7 ( �l�
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING 'A' Applied . . : 09/14/2007
Parcel No...: 210108278002 Issued . . : O1/14/2008
Project No : ����� _�z � Expires . .: 07/12/2008
OWNER LODGE PROPERTIES INC 09/14/2007
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 09/14/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License : 668-5
CONTRACTOR ENCORE ELECTRIC 09/14/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-5
Desciption: VAILS FRON"T DOOR BUILDING 'A' WIRE AND PIPE ONLY
Valuation: $106,563.00
a+**r�r*r*r�+�**►***r*:r*�+*�are*►�+r******at�s*:rr�***�****+*****x*** FEE SUMMARY �`a*****�*+**a�+►******�r*****ax****t�*r+r**e***r�*�+****+►+*
Electrical---------> $o.o o Total Calculated Fees--> $4,z 2 a.11
DRB Fee---------> $o.o o Additional Fees----------> $o.o 0
[nvestigation----> $0.00 Total Permit Fee--------> $4,228.11
W ill Call---------> $0.0 0 Payments------------------> $4,2 2 8.11
TOTAL FEES--> $4,2 2 a.i i BALANCE DUE--------> $o.o 0
a****rw�►�****�**s****..r:+*�rr*+******tv*x.**�.**��*r��+��*«*:**r*rt*��*�*r►r►�*������***t«**�:**r**r*�+r�*r*a**«+r�t�+*+**r�*r�**.*+*r*++r«+r+►
Approvals:
Item: 05600 FIRE DEPARTMENT
09/24/2007 mcgee Action: DN Plans cio not meet minimum requirements tor
or review.
Plans do not reflect ceiling heigth or slope in all rooms .
Walls and beams are not distinguishable.
Beam depth is not specified.
Plans do not contain information required under
NFPA 72 - 4 . 5 . 11 . .Recommend reviewing appednicies as well .
10/11/2007 mcgee Action: AP wire pull permit .
The wire pull permits are approved subject to final changes on the alarm plans
from BCER.
**�*..*****.»�**.*.****•*�********»�.***.�****►�*�*.*.****�+.+******«***..*:*�*����*�+**.*«**s**.**.****s�*�*..,..******«*.*.��.�.....*�.***++*.*
CONDITIONS OF APPROVAL
..*�,*..**..*.*�.�**,..*,*..**.*.*.*****.*.*.*�.*.�***.***.*«*,**.*.*.*.***.*.**M********.�.�*.*�.�..*�,:..**,*.*.*.�.�*�**�.....**,:*.*.*�.*�.....
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable t reto.
REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVAN ELE HON�F.9�-�?� 79-2252 FR DA-AM-5 PM.
SI RE O O TRACTOR FOR HIMSELF AND OWNER
******�****************************+********************************************************
TOWN OF VAIL, COLORADO Statement
************************************************************�*******************************
Statement Number: R080000053 Amount: $4,228 . 11 O1/14/200801:32 PM
Payment Method: Check Init: DDG
Notation: Encore Electric
1883
-----------------------------------------------------------------------------
Permit No: A07-0098 Type: ALARM PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $4,228 .11
This Payment: $4,228. 11 Total ALL Pmts: $4,228 .11
Balance: $0. 00
***************�***********************************+****************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------—---------- ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 3, 996.11
PF 00100003112300 PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
HYDERSUBMITTAL COVER
CONSTRUCTION INC.
543 Santa Fe Drive,Denver,Colorado 80204
Phone:(303)825-1313 Fax:(303)825-3223
Email:info@hyderinc.com Website:www.hyderinacom
TO: Town of Vail DATE: �-2t�z�99�.,,
� lalo�
PHONE:
ATTENTION: Charlie Davis
PROJECT: VFD Site Work & Bldg A - Garage/Dock
HCI Job No. 26006
WE SENDIN • BMITTED F R: A TION T N:
❑ Shop Drawings � Approval ❑ Approved as Submitted
� Letter � Your Use ❑ Approved as Noted
❑ Prints � As Requested ❑ Retumed After Loan
❑ Change Order � Review and Comment ❑ Resubmit
❑ Plans ❑ Submit
❑ Sam les SENT VIA: ❑ Returned
❑ Specifications ❑ Attached ❑ Returned for Corrections
❑ Other: ❑ Separate Cover Via: ❑ Submittal Return Date:
Remarks: Vails Front Door permit#B06-0018 Building A Generator Load test report for review and acceptance.
cc: Signed:
Kyung Kim
__-- ___.___.�,�.�....Q_�.x,�.,.,a.�„� -,�.�._,-�._�h�«��
Rocky
Mountain
�
December 6, 2007 ��� � �' ����
Job/GL Gode;
�ccrued Tax:
_...,,,._ .,.
Encore Electric '
2107 West College Avenue
Englewood, Colarado 80110
Project and Equipment Reference: Vail's Front Door
Onan Generator Set Made1350DFEG, s/n 8070017711
To Whom It May Concern:
Start up and systems check out of the above referenced project and equipment has baen
completed on November 16, 2007.
The one year warranry has commenced as of the start up and systems check out date.
Cummins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equipment and we appreciate the
opportunity to do business with you. If we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
Power Gs�2eration Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Henderson,CO 806d0
Phone 303 287 0201
Fax 303 286 3776
Toll Free II00 927 7201
��
i �
Cummins Rocky Mountain, lndustrial/Generator Division
8213 East 96th Avenue, Henderson, Co 80640-8523
Phone (303) 286-7697 Fax (303} 287-4837
Initial Start Up
System Checkout and Test Record
Start Up Date: � �n ivaV ��
Owner.• VA/L'S FRONT DOOR
VAIL'S FRONT DOOR
959 VAIL LANE
VAIL, COLORADO 81657
Contractor: ENCORE ELECTRIC, INC.
2107 WEST COLLEGE AVENUE
ENGLEWOOD, �OLORADO 809?0
, �:;,.
Manufacturer: onan ;
Vlodel Number.350 DFEG ���p/�p �
Serial Number. v7e�oi7 7// ���`
J�.
��-:�.'�"' ,
R _ ...
Manufact�.cw, ' Zen�#h
Vlodel Nutmb .�,TG 800 Z�� A-E� o — L5`7 FSn�- —Z-
Serlal Number. . � � j-�;;� �
Manufacturer: Zenith
Vlodel Number,zTG soo Z�5` !�-vf;;��/ �--C�7�sU�jt --�
Serial Number:_ 15l �'"I l-- l ��
Manufacturer: Y,_
Vlodel Number: °��'�
Seriai Number:
Manufact�rer.
Vlodel Number:
, .,_:_=,Serlal Number:
Manufacturer:
Vlo�1�1 Number: _.. �
.S�rial�lumber:
Manufacturer:
Vlodel Number:
Serial Number.
Page 1
. ,
I
Init►al Installation and Prestprt Checks
I Sound REA )NGS: ; Please Click Sound Readings Link to Access Form
Fue►Sy'�
�Natural Gas �LPG Vapor �LPG Liquid
Manua!Shut Off Valve
Primary Cas Pressure Regulator
Gas Votume Surge Tank
Dry Fuel Stralner
Flexfbie Fue/Connectlon
Gas Available;_Water Column No Load,_Water Column Full-Load
�Gasollne
Flex/ble Fue/Connectlon Supply
Primer Tank(If Requiredl
Gasol)ne Avaflable
Primed
iesel
Flexlble el Connectlons fsupp/y and Rerurnl
o Englne �Supply Tank �Day Tank
ase Tank
�Day Tank
Screen�FflterASSemblyAhead of Fuel lnlet
Fue!Transfer Pump and/or Solenold Valve
Day Tank�Ioat Switch Wired to Fuel Transfer Pump (A.C. or D.C.1
CheckValves on Englne
Fuel Return/Overflow Line to Maln Tank One Size Larger than Supply
u eve!below In�ectors
le uel Avallable
eed�1ese!
Exhausi System
Flexib/e Exhaust Tubing
E ust Condensatfon Trap �v r �G� ��''G L,"�G
er
or Exhaust Piping Slze
ong-Radius Exhaust Elbows
Ex `st Thlmble
ain Cap/Beveled End wfth Screen
rayc 2
� --___________..
�
Initial Installation and Prestari Checks
Mode%
E/ecfrica/Check Oui S/N:
AMPS: '
Generator Maln Circuft Breaker- Closed
Phase Rotation atATS
�Clockwise Rotation tAeCJ �Counter Clockwise Rotation fAC81
�ATS Voltage set points
�Under Vo/tage ��� t (�
BPick Up 9�0 of Normal
Drop Out 9�0 of Pickup
[�Over Voltage
�Drop Out 9�0 of Normal
Delay seconds
�Frequency Sensing at ATS
BPfckup % of Norma!
De/ay seconds
Voltage
Hertz
Aliow Proper No Load Warm Up
Start up(Add load)
e or Svultch 1n Run Positfon
dd Load by Load Bank-if required
Automatic Starl
SetATS Tlme Delays
RE-Check Oil&Coolant Levels
Selector Swltch in AUTO Operatfon Genset
ATS Lfnear Mvtor Swltch- On
Slmulate Power Failure
(Lltfiltyr Mafn Breaker or T.est�vitch at the Awtomatfc Transfer Swltci�l
Engine/Generaio►
E e Start OK
e&Gen rator Under toad OK
D ess re�ibs
Temperature � Degrees
nusual NoisesNibra fons
�
Page 5
�. -- __._._._.__., _ _, :_ �v..,
Initiol Installotion and Prestart Checks
Model:
Auiomatic Loqd Transfer Switch S/N:
Transfer to Emergency- OK j
Remove toad fMaln ereaker or Test Switch in the Auto Load Transfer Switchl
Start Tlme Delay Seconds
Transfer Tlme Delay Seconds
Program Transltfon Time De/ay seconds
Vottage
Hertz
Return Load to Normal lMain Breaker or Test SwitchJ
Re-TransferTlme Delay minutes
Program Transition Time Delay seconds
Re-Transfer to Normal OK
Cool Down Perlod minutes
Englne Shut-DOwn OK
Acceuories
Supply Tank to Engine
Remote Annunc/ator Functlonal
Set Battery Charger Chargfng Rates
VDC Float VDC
VDC Epualfze VDC
aExereserCiock, set t►me and day
�Set Exerclse Perlod
finaf Instailatfon Recommendallons
I
�
Page 6
Initial lnstallation and Presfart Checks I'
Onan Warronty lnitiallon
Engine/Generator-In Service Date: r� �/� �'i
Automatic load Transfer Swttch -In Servlce Date:
Check Out&Initial Start Up
Performed By: �,��� Date: ���� f '��
Performed By: Date:
Witnessed By:��f���j.,�{-j-�,'_, Date: 6 �
Company: k-°,,�JC�� �(�:c.T.�c.-c.�,:
Flnal Check
Engine Switch In Remote Posltion
Generator Ffeld ereaker On
Transfer swltch connected to Normal
Transfer SwTtch in Auto Posltion
Exercfser Clock Operatlonal
Instruction Given To:
nowner �atP:
�Contractor Date:
�Other, Speclfy Date:
Date:
Date:
Date:
i
Page 7
Generetor Model and Cantro!Informatian �I
Complete Generator Set Model and Spec. Number ��i'c::�, �?�';��c�cl f �
Generator Seri�1 Number l�x��7v���-7 "���
Controi: 100 ControL•
3100 Contral:
3200 ControL-
other:
Where applicable llst generator control information.
Control calibratfon P/N: 3�- L-/S�'
Control checksum number:
List All Feature P/N's:_ �s'y��z-
.�'�'j�c%"��f
S��i?
SJ L�,
ss7�j
�3�7
Sl�s3
— �'"Fv E'.i
- S 7LZ-
s'��7
s78n
G /S`21'
_ �/S�f
_ Gr/ /
Page 8
C u m m i n s �ndustria! / Generator Div'rsion
8213 East 96th Avenue • Henderson, CO 80640
R O C K Y M O U N T A I N L L.C Phone: 303-287- - - _ I
0201 • 800 927 7201 Fax: 303 286-3776
Load Bank Test Results
Job Name: ��i� - �"� �� � �i c
� J 7� � � �7
Date: ��,//� � 7
Contractor: ��`t�C�c'�'�'-c:" �C Fr�� l �
Power Factor: ',
Model Number: ��� �7��!� �� Hours 7ested: �
Serial Number: '7��70 (tJ(�7 7 // Performed By: ✓��. ��
�
Voltage Voltage Voitage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
f>�Y� �°��' �f���' �f�� %fau ��'v �va 3.�� �a0 `f`�1 /z3�
��rs �°�� �� �v �fU�� �fov yc�u :3 3l- �.iG� �7 ����
��e�� ��� ��� �%�v ��� ��a �v�a �3�- v�? �`1' !���
�`�r S �f�r� �t�'� ��r) �t�C� vf�� �i�� � .�.��'� �ca ��� ��%��
�y�`f�'� .' � ✓t _ U 1/�l)C� r, . ,� _ � ,, ..-
f?''�J d7��' �`�' �OCJ `��'� J.� � (�li �'Yj' l`'i 7
1�r�' y�'v �n `f fl� �a� ��r� �vca �3z G�U �� !��
���t� ��'c� ���� tf� �f U r� �f UU' �fr�c� ?� �l '�f r� !�7
t r s ��v ��� �f� � �v �uo �aa � 3� �o � f u�
l��f� �f�� �f�c� �°i� ��CJ �fv� �a� ��� lO� ��i ���
Comments:
Customer Signature: Date:
�'� _____-- - ._�___..��R
.�..m���._1 �:�.,�-.�;�;:
r
ti
ROCIq/
Mountain
�
December 6, 200� �E� i v' 2007
Jab/GL Code:
'�ccrued Tax:
_�,,,,,._ ,, -
Encore Electric '
2107 West College Avenue
Englewood, Calarado 80110
Project and Equipment Reference: l�ail's Front Door
Onan Generator Set Model 350DFEG, s/n B070017711
To Whom It May Concern:
Start up and systems check out of the abo►�e referenced project and equipment has been
completed on November 16, 2007.
The one year warranty has commenced as of the start up and systems check out date.
Cummins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equapment and we appreciate the
opportunity to do business with you. IJ'we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
�ower Generation Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Henderson,CO 80640
Phone 303 287 0201
F�303 28r 3776
Toll Free 800 927 7201
�nn�
i �
Cummins Rocky Mountain, Industria!/Generator Division
8213 East 96th Avenue, Henderson, Co 80640-8523
Phone (303) 286-7697 Fax (303) 287-4837
Initial Start Up
System Checkout and Test Record
Start Up Date: � b /vaV Q�
Owner.• VAIL'S FRONT DOOR
VA/L'S FRONT DOOR
�59 VAIL LANE
VAIL, COLORADO 81657
Corltractor: ENCORE ELECTRIC, lNC.
2i07 WEST COLLEGEAVENUE
ENGLEWOOD, �OLORADO 80990
. _,;
Manufacturer: Onan ; .
Vlode/Number.350 DFEG ���p/�p � ���:.
Serial Number. ��
_ ,�,.�i t�7t�Q/� �// �,.,.
$�
;��
ka:`
Manufact .r • �eni_th � '�
Vlodel Nuliib .�TG 800 ZC,S A-p o - �`7�Sn� -Z,.
Serfal Number: , � 1 1�';� k
Manufacturer.• Zenith
Vlodel Number.ZTG 800 �G'j S �p�,�j�/ ,--�j��s-U�j� _�
serial Number: _ !S l I!- 1 ��
Manufacturer:
;i....
Vl�de!Number: -
Serial Number:
Manufacturer.
V►ode!Number:
. . ..,..::...Serlal Number;
Manufacturer.•
VJo�I�!Number: _.. �
,S�t�ial Number.
Manufacturer.•
Vlodel Number:
Serial Number;
Page T
' ,
lnitial lnstallation and Prestart Checks
Sownd REAb►NGS: ;. Please Ctick Sound Readings tinK to Access Eorm
Fuel Syslem
�Natural Cas �LPC Vapor �LPG Liquid
Manual Shut Off Valve
Primary Gas Pressure Regulator
Gas Volume Surge Tank
Dry Fue►Stralner
F/exl6le Fue!Connectlon
Cas Available;�Water Column No Load,!Water Column Fu!!-toad
�casoline
F/exlbfe Fue!Connectlon Suppiy
Primer Tank�If Requiredl
GasolJne Avatlab/e
Prfined
iesel
Flexlble el Connections fSUpply and Returnl
o Engine �Supply Tank �Day Tank
ase Tank
�Day Tank
Screen/FilterASSembJyAhead of Fue!In1et
Fue1 Transfer Pump and/or Solenofd Valve
Day Tank Float Switch Wlred to Fuel Transfer Pump (A_C. or D.C 1
CheckValves on Engine
Fuel Return/Overflow Line to Maln Tank One Slze Larger than Supply
u eve!below►n)ectors
fe uel AvallaB/e
eed Dleset
Exhaust System
Flexible Exhaust Tubing
E ust Condensatfon Trap �vT �� ��''L ��C:-
er
or Exhaust Pipfng Size
ong-Radius Exhaust Elbows
Fx st Thlmble
ain Cap/Beveled End wlth Screen
ra yC 2
Inrtial Installotion and Presfarf Checks
Model:
Elecfrical Check Out S/N:
AMPS:
Generator Main Circuft Breaker-Closed I
Phase Rotation atATS �
�Clockwise Rotation(ABCI �Counter Clockwise Rotation fAC81
QATS Voltage set points �
�UnderVoltage L r
BPick Up qo of Normal �.��
Drop Out 9�0 of Pickup
�Over Voltage
Drop Out �o of Normal
Delay seconds
�Frequency Sensing at ATS
Pfckup � of Normal
Delay seconds
Voltage
Hertz
Allow Proper No Load Warm Up
Stad up(Add Load)
e or Svaltch In Run Position
dd Load by Load Bank-ff required
Automaiic Sfad
Set ATS Tfine Delays
RE-Check OfI&CooJant Levels
Selector Swltch In AUTO Operatfon Genset
ATS Unear Motor Swltch-On
SJmulate Power Fafiure
IWtlift�r,Mafn ereaker or Test�witch at the Automatic Trar�sfer Swftchl
Engine/Generator
E e Start OK
e&Gen rator Under Load OK
O ess re�Ibs
Temperature I Degrees
nusual Noises/vlbra ions
Page 5
�
Initial Installation and Prestart Checks
ModeL•
Aufomatic Load Transfer Switch S/N:
i
Transfer to Emergency- OK �
Remove toad fMafn Breaker or Test Swftch in the Auto load Transfer Switch) i
Start Tfine Delay Seconds
Transfer Tlme Delay Seconds
Program TransJtfon Time De/ay seconds
Voltage
Hertz
Return toad to Normat lMain ereaker or Test Switchl
Re-TransferTlmeDelay minutes
Program Transition Time Delay seconds
Re-Transfer to Normal OK
Cool Down Perfod minutes
Englne Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functlonal
Set Battery Charger Charging Rates
VDC Float VDC
VDC Epuallze VDC
�ExereserClock, Set time and day
�Set Exerclse Period
Finaf InstaNatlon Recommendatlons
I
�
Page 6
. i
Initia!Installation and Prestart Checks I
'i
Onan Wananty lnitiation
Engine/Generatar-in Service Date: �'� ��� ��i�
Automatic Load Transfer Swftch -!n Service Date:
Check Out&Initia!Start Up
Performed By: �,�lf� Date: r��� f '��
Performed By: Date:
Witnessed By: ��f���j,�{7-� Date: � 6
company.� k-°,���� ,EI�c.T.�-'c.�-=
Flnal Check
Engine Switch In Remote Posftlon
Generator Fleld ereaker On
Transfer Swltch Connected to Normal
Transfer Switch in Auto Posltfon
Exerciser Clock Operatlonal
Insfruction Given To:
(�owner na�a:
�Contractor Date:
�Other, Specffy Date:
Date:
Date:
Date:
�
I
Page 7
i ._
� M
Generator Modef and Contrai Informatian i
Complete Generatar Set Model and Spec. Number ���c�, �?��=���c'f
GeneratorSerial Number_ 13���7�<�,� �r�
Control: 100 Control.
3100 ControL•
3200 Control:
other:
Where applicab/e 11st generator control fnformation.
Control cal�bratfon P/N: 3�- L-/S�
Gontrol checksum number:
List All Feature P/N's: �'yF�i-
���f�=''f
����
s�c�G�.
�s7°j
ss`�7
��s3
s �.3
- s�Zz- -
��f7
— S7�'n
�r /Sc'1'
G•• /S9
�.r��
Page 8
I � ��� C u m m i n s �ndustriai /Generator Division I
8213 East 96th Avenue • Henderson, CO 80640 �
R O C K Y M O U N T A t N L L C Phone: 303-287-0201 • 800-927-72d1 Fax: 303-286-3776
Laad Bank Test Resuits
Job Name: ��i� � >`�'����" � tai�
Date:__ j�j/C � 7 i
Contractor: ���i���'-� �L�c`�aZ.�f l ��
Power Factor: ;
Model Number: ���j �7�� /(� G��= Hours Tested: � I
Serial Number: _!7��70 (lJ(�7 7 l� Performed By: �/�� ��
Voltage Voltage Voftage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
a�� ��� ���� ��� �a� ����� ���� ,��� �� �� 1��
o�Cs �?�� �� �v �U�� �uv ���� � 3z- �.�G� �7 l���
����5 �'�� �t�J �f�v �f�i� �"�o ���a �3l- U�' �I� f���
��r� �`f�� �f�`'� ��c> �t�(� �-f�� �fiUv 3 ..�.�,� �vc� `f�1� ��,�-
G���'� �'t''�J !�f�c� � �� /J.. << _ E f, ..-
� lu� �'v� �v� 3�.� �� (�u �� �U7
I�r-�' y�v �� �f�a �U� ��� �l�C� �.�'Z- fvv %�� !u�
���t� ���c� ���� �f�u �lr�`t� �fvU Lf�4i �� � `�� r�7
! r S ��� �l�r� �f� o �� �oo �a � 3� �,o � l��
l�4�� �i�� �f�c� ��i1 `fou ��v �o� �.3� �d ��i ���
Comments
,
Customer Signature: Date:
�� --_--- __._a__���..ma,.�
_�.�z,.�.� �:�w
ROCIC]/
Mountain
�
December 6, 2007 9E� � �' �Q��
J�b/GL Gode:
'�ccrued Tax:
_�.,,,,._ �.
Encore Electric '
2107 West College Avenue
Englewood, Colorado 80110
Project and Equipment Reference: Vail's Front Door
Onan Generator Set Mode13SODFEG, s/n B070017711
To Whom It May Concern:
Start up and systems check out of the above referenced project and equipment has been
completed on November 16, 2007.
The one year warranry has commenced as of the start up and systems check out date.
Curnmins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equipment and we appreciate the
opportunity to do business with you. If we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
Power Generation Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Nenderson,CO 806d0
Phone 303 287 0201
Fax 303 286 3776
Toll Free 800 927 7207
i =
� Cummins Rocky Mountain, lndustrial/Generator Division
8213 fast 96th Avenue, Henderson, Co 80640-8523
Phone (303) 286-7697 Fax (303) 287-4837
lnitial Start Up
System Cf►eckout and Test Record
Start Up Date: � �o IvaV 4�
Owner: VA/L�S FRONTDOOR
VA/L'S FRONT DOOR
959 VA/L LANE
VAIL, COLORADO 81657
Contractor: ENCORE ELECTRIC, INC.
2107 WEST COLLEGE AVENUE
ENGLEWOOD, �OLORADO 80�10
, ��-
Manufacturer: onan t
Vlodel Number.350 DFEG ���p/�p � ��
Serial Number: ���p�� ��� ��
,�-
<..:
F'.:.:.
Manufact�rw „• zenith
Vlodel Nut»b .�,TG 800 ZC�` A-E� o - �`��So�- -Z�
Serfal Number.- . ( � J--�:;� �'
Manufacturer: zenith
Vlodel Number.ZTG 800 �S �-of�' �7 �--a7�sU�jS --�
Serial Nurnber: _ t 5� �•�'!l— l ��
Manufacturer: ;{._.
Vl.�del Number: °���`
Seria!Number:
Manufact�rer.
Vlode/Number:
. . .,..:;�=.Serlal Number:
Manufacturer:
Vlo��el Number: . �
.S�t�ia!Number.
Manufacturer:
Vlodel Number:
Serial Number:
Page 1
' Initial lnstallation and Presfart Cftecks
(-Sound REA 1NGS::: Ptease Click Sound Readings Lfnk ta Access Eorm
Fuel System
�Natura!Gas �LPC Vapor �LPG Lipuid
Manual Shut Off Valve
Primary Gas Pressure Regulator
Gas Volume Surge Tank
Dry Fuel Stralner
F/exidle Fue/Connectlon
Cas Avallable;_Water Column No Load,_Water Column Fult-toad
�Caso►Ine
Flexlble Fue/Connectfon Suppfy
Primer Tank(!f Requiredl
Gasollne Avallable
Primed
lese!
Flexible el Connectlons tSupply and Returnl
o Engine �Supply Tank �Day Tank
ase Tank
�Day Tank
Screen/Ff�terAssemblyAhead of Fuel►nlet
Fuel Transfer Pump and/or Solenofd Valve
Day Tank Fioat Switch Wlred to Fuef Transfer Pump fA.C. or D.C.1
CheckValves on Engine
Fuel Return/Overflow Cine to Main Tank One Size Larger than Supply
u eve!below►nj�ectors
fe uel Avallable
eed�Ieset
Exhaust System
Flexible Exhaust Tubing
E ust condensat�on trap �'j'vT C� t�r r%'C �—�'G
er
or Exhaust Plping Size
ong-Radius Exhaust Elbows
Ex st Thlmble
afn Cap/Beveled End with Screen
rvyc 2
�
Initial/nstallation and Prestart Checks
Mode/:
Electrical Check Ouf S/N:
AMPS:
Generator Maln Circuft ereaker- Closed
Phase Rotation atATS
�Clockwlse Rotatlon(ABCI �Counter Clockwise Rotation fACel �
�ATS Voltage set points �
�UnderVoltage ��� t (�
BPick Up 3�, of Normal
Drop Out �o of Pickup
�Over Voltage
Drop Out % af Normaf
DelaV seconds
�Frequency Sensing at ATS
BPfckup % of Norma!
De/ay seconds
Voltage
Hertz
Allow Prpper No Load Warm Up
Start up(Add load)
e or Switch in Run Pos)tfon
dd Load by Load Bank-if required
Automcrtic Sfad
SetATS Tfine Delays
RE-Check Oil&Coolant Levels
Selector Swltch In AUTO Operatfon Genset
ATS tlnear Motor SwJtch- On
S)mu/ate Power Faflure
IWtliftyr,Mafn Breaker or Test�vitch a.t the A�tomatfc Transfer Swftch!
Engine/Generaio►
E e Start OK
e&Gen rator under Load OK
D ess re�ibs
Temperature I Degrees
nusual Noises/vibra fons
Page 5
Jnitial Instaltation and Prestart Checks
Modeh.
Automatic Loqd Transfer Switch S/N:
i
Transfer to Emergency- OK '
Remove load fMaln sreaker or Test Switch in the Auto Load Transfer Switchl
Start Tfine Delay Seconds
Transfer T1me Delay Seconds
Program Transftion Time De/ay Seconds
Voltage
HertZ
Return Load to Normal(Main 8reaker or Test Switchl
Re-Transfer Ttme Delay minutes
Program Transition Time Delay seconds
Re-Transfer to Normal OK
Coo/Down Perlod mtnutes
Englne Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functlonal
Set Battery Charger Charging Rates
VDC F/oat VDC
VDC Epuallze VDC
�Exere serGock, Set tlme and day
❑Set Exerclse Pertod
Flnal Inslallatfon Recommendallons
i
Page 6
lRif� i
ral Instatlat►on and Presfart Checks �
Oncrn Waaantylnitiation
Englne/Ceneratar-In Service Date: ri �/� �'i
Automatic Load Transfer Swttch -!n Servfce Date:
Check Out&Initial Siari Up
Performed By: �,�11� Date: r��� � ��
Performed 8y,• Date:
WitnessedBy: ��,rV�`�j,,�j-��„ Date: ///�j��
company: k°�lC��- �(�G-T'��.% _..�F�_-
F/nal Check
Engine Switch/n Remote Posltlon
Generator Ffeld ereaker On
Transfer Switch connected to Normal
Transfer Swftch in Auto Positfon
Exercfser Clock Operatlonal
lnsfrucHon Glven To:
�owner �atp_
�Contractor Date:
�Other, Speclfy Date:
Date:
Date:
Date:
�
Page 7
.�
, ;
Generatar Model and Control Informatian '
Complete Gerrerator Set Model and Spec. Number ��rr�, �?<<;���cl,c I
�enerator Serial Number 13���7����-7 ���
Control: 1�Contral:
3100 ControL•
3200 Control:
other:
Where applicab/e llst generator control informatfon.
Control calibratfon P/N: 3�- G/.s'�
Control checksum number:
ListAll Feature P/N's: �s���
.�K'f`�=''f
J���
sS�
�s�
ss�7
3l,�s3
- �' S3
-- S 7ZZ-
�'*i�7
S7S�
(, 1 S1s'
I - G /S�
4.+�n
I
Page 8
Inrtial Installotion and Presfarf Checks
Model:
Elecfrical Check Out S/N:
AMPS:
Generator Main Circuft Breaker-Closed I
Phase Rotation atATS �
�Clockwise Rotation(ABCI �Counter Clockwise Rotation fAC81
QATS Voltage set points �
�UnderVoltage L r
BPick Up qo of Normal �.��
Drop Out 9�0 of Pickup
�Over Voltage
Drop Out �o of Normal
Delay seconds
�Frequency Sensing at ATS
Pfckup � of Normal
Delay seconds
Voltage
Hertz
Allow Proper No Load Warm Up
Stad up(Add Load)
e or Svaltch In Run Position
dd Load by Load Bank-ff required
Automaiic Sfad
Set ATS Tfine Delays
RE-Check OfI&CooJant Levels
Selector Swltch In AUTO Operatfon Genset
ATS Unear Motor Swltch-On
SJmulate Power Fafiure
IWtlift�r,Mafn ereaker or Test�witch at the Automatic Trar�sfer Swftchl
Engine/Generator
E e Start OK
e&Gen rator Under Load OK
O ess re�Ibs
Temperature I Degrees
nusual Noises/vlbra ions
Page 5
�
Initial Installation and Prestart Checks
ModeL•
Aufomatic Load Transfer Switch S/N:
i
Transfer to Emergency- OK �
Remove toad fMafn Breaker or Test Swftch in the Auto load Transfer Switch) i
Start Tfine Delay Seconds
Transfer Tlme Delay Seconds
Program TransJtfon Time De/ay seconds
Voltage
Hertz
Return toad to Normat lMain ereaker or Test Switchl
Re-TransferTlmeDelay minutes
Program Transition Time Delay seconds
Re-Transfer to Normal OK
Cool Down Perfod minutes
Englne Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functlonal
Set Battery Charger Charging Rates
VDC Float VDC
VDC Epuallze VDC
�ExereserClock, Set time and day
�Set Exerclse Period
Finaf InstaNatlon Recommendatlons
I
�
Page 6
. i
Initia!Installation and Prestart Checks I
'i
Onan Wananty lnitiation
Engine/Generatar-in Service Date: �'� ��� ��i�
Automatic Load Transfer Swftch -!n Service Date:
Check Out&Initia!Start Up
Performed By: �,�lf� Date: r��� f '��
Performed By: Date:
Witnessed By: ��f���j,�{7-� Date: � 6
company.� k-°,���� ,EI�c.T.�-'c.�-=
Flnal Check
Engine Switch In Remote Posftlon
Generator Fleld ereaker On
Transfer Swltch Connected to Normal
Transfer Switch in Auto Posltfon
Exerciser Clock Operatlonal
Insfruction Given To:
(�owner na�a:
�Contractor Date:
�Other, Specffy Date:
Date:
Date:
Date:
�
I
Page 7
i ._
� M
Generator Modef and Contrai Informatian i
Complete Generatar Set Model and Spec. Number ���c�, �?��=���c'f
GeneratorSerial Number_ 13���7�<�,� �r�
Control: 100 Control.
3100 ControL•
3200 Control:
other:
Where applicab/e 11st generator control fnformation.
Control cal�bratfon P/N: 3�- L-/S�
Gontrol checksum number:
List All Feature P/N's: �'yF�i-
���f�=''f
����
s�c�G�.
�s7°j
ss`�7
��s3
s �.3
- s�Zz- -
��f7
— S7�'n
�r /Sc'1'
G•• /S9
�.r��
Page 8
I � ��� C u m m i n s �ndustriai /Generator Division I
8213 East 96th Avenue • Henderson, CO 80640 �
R O C K Y M O U N T A t N L L C Phone: 303-287-0201 • 800-927-72d1 Fax: 303-286-3776
Laad Bank Test Resuits
Job Name: ��i� � >`�'����" � tai�
Date:__ j�j/C � 7 i
Contractor: ���i���'-� �L�c`�aZ.�f l ��
Power Factor: ;
Model Number: ���j �7�� /(� G��= Hours Tested: � I
Serial Number: _!7��70 (lJ(�7 7 l� Performed By: �/�� ��
Voltage Voltage Voftage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
a�� ��� ���� ��� �a� ����� ���� ,��� �� �� 1��
o�Cs �?�� �� �v �U�� �uv ���� � 3z- �.�G� �7 l���
����5 �'�� �t�J �f�v �f�i� �"�o ���a �3l- U�' �I� f���
��r� �`f�� �f�`'� ��c> �t�(� �-f�� �fiUv 3 ..�.�,� �vc� `f�1� ��,�-
G���'� �'t''�J !�f�c� � �� /J.. << _ E f, ..-
� lu� �'v� �v� 3�.� �� (�u �� �U7
I�r-�' y�v �� �f�a �U� ��� �l�C� �.�'Z- fvv %�� !u�
���t� ���c� ���� �f�u �lr�`t� �fvU Lf�4i �� � `�� r�7
! r S ��� �l�r� �f� o �� �oo �a � 3� �,o � l��
l�4�� �i�� �f�c� ��i1 `fou ��v �o� �.3� �d ��i ���
Comments
,
Customer Signature: Date:
�� --_--- __._a__���..ma,.�
_�.�z,.�.� �:�w
ROCIC]/
Mountain
�
December 6, 2007 9E� � �' �Q��
J�b/GL Gode:
'�ccrued Tax:
_�.,,,,._ �.
Encore Electric '
2107 West College Avenue
Englewood, Colorado 80110
Project and Equipment Reference: Vail's Front Door
Onan Generator Set Mode13SODFEG, s/n B070017711
To Whom It May Concern:
Start up and systems check out of the above referenced project and equipment has been
completed on November 16, 2007.
The one year warranry has commenced as of the start up and systems check out date.
Curnmins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equipment and we appreciate the
opportunity to do business with you. If we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
Power Generation Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Nenderson,CO 806d0
Phone 303 287 0201
Fax 303 286 3776
Toll Free 800 927 7207
i =
� Cummins Rocky Mountain, lndustrial/Generator Division
8213 fast 96th Avenue, Henderson, Co 80640-8523
Phone (303) 286-7697 Fax (303) 287-4837
lnitial Start Up
System Cf►eckout and Test Record
Start Up Date: � �o IvaV 4�
Owner: VA/L�S FRONTDOOR
VA/L'S FRONT DOOR
959 VA/L LANE
VAIL, COLORADO 81657
Contractor: ENCORE ELECTRIC, INC.
2107 WEST COLLEGE AVENUE
ENGLEWOOD, �OLORADO 80�10
, ��-
Manufacturer: onan t
Vlodel Number.350 DFEG ���p/�p � ��
Serial Number: ���p�� ��� ��
,�-
<..:
F'.:.:.
Manufact�rw „• zenith
Vlodel Nut»b .�,TG 800 ZC�` A-E� o - �`��So�- -Z�
Serfal Number.- . ( � J--�:;� �'
Manufacturer: zenith
Vlodel Number.ZTG 800 �S �-of�' �7 �--a7�sU�jS --�
Serial Nurnber: _ t 5� �•�'!l— l ��
Manufacturer: ;{._.
Vl.�del Number: °���`
Seria!Number:
Manufact�rer.
Vlode/Number:
. . .,..:;�=.Serlal Number:
Manufacturer:
Vlo��el Number: . �
.S�t�ia!Number.
Manufacturer:
Vlodel Number:
Serial Number:
Page 1
' Initial lnstallation and Presfart Cftecks
(-Sound REA 1NGS::: Ptease Click Sound Readings Lfnk ta Access Eorm
Fuel System
�Natura!Gas �LPC Vapor �LPG Lipuid
Manual Shut Off Valve
Primary Gas Pressure Regulator
Gas Volume Surge Tank
Dry Fuel Stralner
F/exidle Fue/Connectlon
Cas Avallable;_Water Column No Load,_Water Column Fult-toad
�Caso►Ine
Flexlble Fue/Connectfon Suppfy
Primer Tank(!f Requiredl
Gasollne Avallable
Primed
lese!
Flexible el Connectlons tSupply and Returnl
o Engine �Supply Tank �Day Tank
ase Tank
�Day Tank
Screen/Ff�terAssemblyAhead of Fuel►nlet
Fuel Transfer Pump and/or Solenofd Valve
Day Tank Fioat Switch Wlred to Fuef Transfer Pump fA.C. or D.C.1
CheckValves on Engine
Fuel Return/Overflow Cine to Main Tank One Size Larger than Supply
u eve!below►nj�ectors
fe uel Avallable
eed�Ieset
Exhaust System
Flexible Exhaust Tubing
E ust condensat�on trap �'j'vT C� t�r r%'C �—�'G
er
or Exhaust Plping Size
ong-Radius Exhaust Elbows
Ex st Thlmble
afn Cap/Beveled End with Screen
rvyc 2
�
Initial/nstallation and Prestart Checks
Mode/:
Electrical Check Ouf S/N:
AMPS:
Generator Maln Circuft ereaker- Closed
Phase Rotation atATS
�Clockwlse Rotatlon(ABCI �Counter Clockwise Rotation fACel �
�ATS Voltage set points �
�UnderVoltage ��� t (�
BPick Up 3�, of Normal
Drop Out �o of Pickup
�Over Voltage
Drop Out % af Normaf
DelaV seconds
�Frequency Sensing at ATS
BPfckup % of Norma!
De/ay seconds
Voltage
Hertz
Allow Prpper No Load Warm Up
Start up(Add load)
e or Switch in Run Pos)tfon
dd Load by Load Bank-if required
Automcrtic Sfad
SetATS Tfine Delays
RE-Check Oil&Coolant Levels
Selector Swltch In AUTO Operatfon Genset
ATS tlnear Motor SwJtch- On
S)mu/ate Power Faflure
IWtliftyr,Mafn Breaker or Test�vitch a.t the A�tomatfc Transfer Swftch!
Engine/Generaio►
E e Start OK
e&Gen rator under Load OK
D ess re�ibs
Temperature I Degrees
nusual Noises/vibra fons
Page 5
Jnitial Instaltation and Prestart Checks
Modeh.
Automatic Loqd Transfer Switch S/N:
i
Transfer to Emergency- OK '
Remove load fMaln sreaker or Test Switch in the Auto Load Transfer Switchl
Start Tfine Delay Seconds
Transfer T1me Delay Seconds
Program Transftion Time De/ay Seconds
Voltage
HertZ
Return Load to Normal(Main 8reaker or Test Switchl
Re-Transfer Ttme Delay minutes
Program Transition Time Delay seconds
Re-Transfer to Normal OK
Coo/Down Perlod mtnutes
Englne Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functlonal
Set Battery Charger Charging Rates
VDC F/oat VDC
VDC Epuallze VDC
�Exere serGock, Set tlme and day
❑Set Exerclse Pertod
Flnal Inslallatfon Recommendallons
i
Page 6
lRif� i
ral Instatlat►on and Presfart Checks �
Oncrn Waaantylnitiation
Englne/Ceneratar-In Service Date: ri �/� �'i
Automatic Load Transfer Swttch -!n Servfce Date:
Check Out&Initial Siari Up
Performed By: �,�11� Date: r��� � ��
Performed 8y,• Date:
WitnessedBy: ��,rV�`�j,,�j-��„ Date: ///�j��
company: k°�lC��- �(�G-T'��.% _..�F�_-
F/nal Check
Engine Switch/n Remote Posltlon
Generator Ffeld ereaker On
Transfer Switch connected to Normal
Transfer Swftch in Auto Positfon
Exercfser Clock Operatlonal
lnsfrucHon Glven To:
�owner �atp_
�Contractor Date:
�Other, Speclfy Date:
Date:
Date:
Date:
�
Page 7
.�
, ;
Generatar Model and Control Informatian '
Complete Gerrerator Set Model and Spec. Number ��rr�, �?<<;���cl,c I
�enerator Serial Number 13���7����-7 ���
Control: 1�Contral:
3100 ControL•
3200 Control:
other:
Where applicab/e llst generator control informatfon.
Control calibratfon P/N: 3�- G/.s'�
Control checksum number:
ListAll Feature P/N's: �s���
.�K'f`�=''f
J���
sS�
�s�
ss�7
3l,�s3
- �' S3
-- S 7ZZ-
�'*i�7
S7S�
(, 1 S1s'
I - G /S�
4.+�n
I
Page 8
! Industrial / Generator Division �
� C u m m i n s 8213 East 96th Avenue • Henderson, CO 80640 �
R O C K Y M O U N T A 1 N L L C Phone: 303-287-0201 • 800-927-7201 Fax: 303-286-3776
Load Bank Test Resuits
Job Name: �/�i� � ��-'c'�'�r �;, t>i'z Date: f�,�l� !`� � I
Contractor: _ �������'� �L Ft'ia2.��" Power Factor: l ',
� � �
Model Number. ��'�"�j �7�c� /(p C.�� Hours Tested: I
Serial Number: !7��70 (l�(�7 7 /� Performed By: ✓�C� ��
Voftage Voitage Vo(tage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
(/�Z J "T G ��� �7'L�-'' T Ti't,% ^Zd(J �L'C� �U!�' .3.�1i [s'D �� /`� �
d��,� �'�� �� �'v �Uu �-uv �cju 3 3Z- �G� �f 7 l���
��Q�t{ ��� 4��J �f�v ��� �vo �v� �3�- U�? �I' f���
c�`�r 5 �{�J �f�� ��c> lt�(� vfv� �fi�� 3 ..�.�,� �c� �� ��%,�:.
� , � � f „ � , „ ...
�y�� �f�v �r�� �cv ur� �v� �v� ��.� �� �; �� i�7
Jr�r� y�v �� `f°� ��v �u�� �vC� ��z- G�v �� !°7
���t� ��'c� ���� �f�,�.t> �jUr� �fUr� �fr�G� �� � `�� lv�
t r S ��� �f�ca �f� o �� �ao �a� � 3� �o � f u�
l��r� �i�� �`�'c� �°� �oU ��v �o� �3y �� �f� ���
Comments:
i
Customer Signature: Date:
---_��. .�.�z. t 2�,�r_�- �—
�
ROCICy
Mountain
�
December 6, 2�07 ��� � µi �Q��
JablGL Gode:
accrued Tax:
_� ,,,._ ,,.
Encore Electric '
2107 West College Avenue
Englewood, Colorado 80110
Project and Equipment Reference: Vail's Front Door
Onan Generator Set Mode1350DFEG, s/n 8070017711
To Whom It May Concern:
Start up and systems check out of the above referenced project and equipment has been
completed on November 16, 2007. I
The one year warranty has commenced as of the start up and systems check out date.
Cummins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equipment and we appreciate the
opportunity to do business with you. If we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
Power Generation Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Henderson,CO 60640
Phone 303 287 0201
Fax 303 286 3776
Toll Free 800 927 7201
I *
� Cummins Rocky Mountain, Industria!/Generator Division
8213 East 96th Avenue, Henderson, Co 8064Q-8523
Phone (303) 286-7697 Fax (303) 287-4837
Initial Start Up
System Checkout and Test Record
Start Up Date: ' � I�aV 0�
Owner: VAIL`S FRONT DOOR
VA/L'S FRONT DOOR
959 VAIL LANE
VA1L, COtORADO 81657
Contractor: ENCORE ELECTRlC, INC.
2107 WEST COLLEGE AVENUE
ENGLEWOOD, �OLORADO 80990
, -�'.
Manufacturer: Onan 3
Vlode/Number.350 DFEG ���p/(p �" ;�:�
Ser►al Number. ���p�� ��� ;�,�;
.':a:�a:-'."
F ,.:.
Manufact�r; • Zen�rh
Vlodel Nui»b .�,TG 800 ZC� A-d o — l5`7�SO�- —Z
Serfal Number.• . / � j�;;� x
Manufacturer. zenith
Vlodel Number,zTG 80o ZGj 5` 1�-vP�j3'/ �--Cj7�s(��jS --�
Serial Nurnber. �5l �/1-- d -�
Manufacturer. Y.,.
V[odel NWmber. °
Serial Number:
Manufactc�rer.
vlodel Number:
. . ..,�;_�.Seria!Number:
Manufacturer:
wo�p►�el Number: __..:. �
,S�t'ial Number:
Manufacturer:
Vlodel Number:
Serial Number.•
Page 1
lnitfal Installation and Prestart Cfrecks
Sound REA )NGSs ; Please Ctick Saund Readfngs tink to Access Form
Fuel Sysiem
�Natural Gas �LPG Vapor �LPG Liquid
Manual Shut Off Valve
Primary Gas Pressure Regutator
Gas Vo/ume Surge Tank
Dry Fuel Strafner
Flexf6le Fuel Connectlon
Gas Ava)l�ble;_Water Column No toad,_Water Column Fu!!-Load
❑caso►jne
Flexible Fuel Connectlon Supply
Primer Tank(If Requiredl
Gasol)ne Avallable
Primed
lesel
F/exible el Connectlons fSupp/y and Return)
o Engine �Supply Tank �Day Tank
ase Tank
�Day Tank
Screen/FilterAssemblyAhead of Fuellnlet
Fue!Transfer Pump and/or Solenold Valve
Day Tank Float Switch Wlred to FueJ Transfer Pump fA.C. or D.C.1
Check Valves on Englne
Fuel Return/Overffow Line to Maln Tank One Slze Larger than Supply
u eve!below►ntectors
le uel Avaflable
eed Dlesel
Exhausf System
F/exiple Exhaust Tubing
E ust Condensatfon Trap �vT �C �i''L L�G:-
er
or Exhaust Plpfng Slze
ong-Radfus Exhaust Elbows
Ex st Thlmble
aln Cap/Beveled End wlth Screen
Payc 2
� --- ___--__
Initial lnstallation and Prestart Checks
Model:
Electrical Check Oui S/N:
AMPS: '
Cenerator Mafn Circuit Breaker- Closed
Phase Rotation atATS
�Clockwfse Rotatlon tA8C1 �CounterClockwise Ratat►on fACeJ
QATS Voltage set points
�Under Voltage ���/ l r�
Pick Up 3�, of Normal
Drop Out 9�0 of Pfckup
�Over Voltage
Drop Out % of Normal
De/ay seconds
�Frequency Sensing at ATS
Pfckup 9�0 of Norma!
Delay seconds
Voltage
Hert7
Allow Proper No Load Warm Up
Start up(Add load)
e or Svaltch In Run Posltfon
dd toad by Load Bank-if repuired
Automatic Stari
Set ATS Tfine Dela ys
RE-Check Ofl&Coolant Levels
Selector Swltch ln AUTO Operatfon Genset
ATS Lfnear Motor Switch- On
S)mu/ate Power Fallure
IWtlfft7r,Mafn Breaker or Test�vitch at the Awtomatfc Transfer Swftcf�l
Engine/Generaior
E e Start OK
e&Gen rator Under Load OK
O ess �Ips
Temperature I Degrees
nusual NoisesNibra ions
Page 5
Initial lnstallation and Prestart Checks
ModeL•
Automatic Loard Trpnsfer Switch S/N:
Transfer to Emergency- OK
Remove Load(Mafn ereaker or Test Switch in the Auto Load Transfer Switchl
Start Time Delay S2COndS
Transfer Tlme Delay Seconds
Program Transltion Time Delay Seconds
Voltage
Hertz
Return Load to Normal lMain 8reaker or Test Switchl
Re-Transfer Tfine De/ay minutes
Program Transition Time De/ay seconds
Re-Transfer to Normal OK
Coo!Down Perlod minutes
Englne Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functlonal
Set Battery Charger Charging Rates
VDC Float VDC
VDC Equallze VDC
�Exere ser Clock, Set time and day
QSet Exercise Perfod
Final Instailaflon RecommendaHons
i
Page 6
Initial lnsfallation and Presfart Checks �
�
Onan War�anty lnifiation
Englne/Ceneratar-In Service Date: ri �/� �'i
Automatic Load Transfer Swltch -In Servlce Date:
Check Out&Initial Slad Up
Performed By: ��1�� Date: ���� f '��
PerPormed sy.• �ate:
Witnessed sy. `
�� �l�fT� Date: � � �
CompanV• k°,,�/C�Y�.- ���t,-]"��.:
Final Check
Engine Switch In Remote Posftlon
Generator Ffeld Breaker On
Transfer Swltch Connected to Normal
Transfer Swltch in Auto Positfon
Exercfser C/ock Operatlonal
Insfruction Given To:
�owner �atP_
�Contractor Date:
�Other, Speclty Date:
Date:
Date:
Date:
�I
Page 7
Generator Model and Control Information 'I
Complete GeneratorSet Model and Spec. Number ��rc:�� ��������c'f
Generator SeriaJ Number T���7v<��7 ���
Control: 100 Controh.
3?0o Controh.
3200 Control:
other:
Where applicable llst generator control Informatfon.
Control calibratfon P�N: 3�- �/s-�
Control checksum number:
ListAll Feature P/N's: <s��z-
������
����
S3�a
_ TS�
�-3`�'7
��r3
— �'��'.:3
— s 7 Zz-
s�'�7
57Sn
G /s�3
i�sq
�� �
Page 8
industriai / Generator Division
� C U !'1'1 1'1''1 1 �'"i 5 8213 East 96th Avenue • Henderson, CO 80640 �
R O C K Y M O U N T A 1 N L l.C Phone: 303-287-0201 • 800-927-7201 Fax: 3Q3-286-3776 '
Load Bank Test Results
Job Name: f/<�ic S ��i��-�r � ��t
Date:_ r�/l� � 7
Contractor: _ ��'t�tt���� �L Fr ia�� Power Factor: f I
�
Modei Number. ���i �7�c� /�v C�� Hours Tested: � I
Serial Number: !.7��70 (tf("7 7 (/ Performed By: ✓��� ��
Voltage Voltage Voftage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
a7�' �°��' �f��� ��� �a U ���v �v� 3.��- �a 't� /�3�
!�'�lS �i:� �c� �J �U�'� �UC� L f GfiJ .�✓ �JZ� �'Gj � l L'�
��e�{ ��� �tG J ��v ���j �aa �v�a �3�- ��? �I� !���
��r � �f�r> lt�� ��r.> �t�C� vf�� �fUC� 3 .�.�� �c� `f t� t�%,��
c���f� �'�v ��� ��v �'ur� �vt� �v� ��:� ,_ G�c; '��' i�?
1��-� �/�v �� `f°� �av �r�� �vv 3�'z (�c� �� !°�
���t� ��� ��°�> �� �f�'t� �fv� �fr���` �� l� '�� r v7
1 I S ��v �f�� �f� o �c� �un �� � 3� �o � f u�
l�4�� �i�� ��'c� `��i� �au ��v �a� 33� bv �� ���
Comments:
�
I
i
Customer Signature: Date:
Rocky
Mountain
.
December 6, 2007 ��� � f° �00�
Jab/GL Code;
>ccrued Tax:
_...,,,.. ,,.
Encore Electric '
2107 West College Avenue
Englewood, Colorado 80110
Project and Equipment Reference: Yail's Front Door
Onan Generator Set Mode13SODFEG, s/n 8070017711
To Whom It May Concern:
Start up and systems check out of the above referenced project and equipment has been
completed on November 16, 2007.
The one year warranry has commenced as of the start up and systems check out date.
Cummins Rocky Mountain LLC considers this testing to be final acceptance of the
equipment.
Please note that maintenance and scheduled service are not included with warranty and
that maintenance in accordance with the manufacturer's instruction/ns and
recommendations will help protect warranty coverage. For information on maintenance
and scheduled service contracts please contact us at 303-927-2282.
It has been our pleasure to supply you with this equipment and we appreciate the
opportunity to do business with you. If we may be of any further assistance,please call.
Cummins Rocky Mountain LLC
Power Generation Division
Robin Johnson
Onan Warranty
Cummins Rocky Mountain LLC
8211 East 96th Avenue
Henderson,CO 80640
Phone 303 287 0201
Fax 303 286 3776
Toll Free 800 927 7201
il , '
'
Cummins Rocky Mountain, Industrial/Generator Division
8213 East 96th Avenue, Henderson, Co 80640-8523
Phone (303) 286-7697 Fax (303) 287-4837
Initia/Starf Up
System Checkout and Test Record
Start Up Date: � �n �a� 4�
Owner: VAIL�S FRONT DOOR
VAIL'S FRONT DOOR
951 VAIL LANE
VAIL, COLORADO 81657
Contractor: ENCORE ELECTRIC, INC.
2107 WEST COLLEGE AVENUE
ENGLEWOOD, �OLORADO 80110
.;_�;
Manufacturer: Onan =
Vlodel Number.350 DFEG 57 p/(p � �
Serial Number. ��r„�pi7 �// �
.�-.
F„_,:.
Manufact�,c4 • Zenith
Vlodel Nuii�b .�,TG 800 ZC s A-F� o - �5`7 FSo�- -Z
Serfal Number. . ! ! 1 . � �`
Manufacturer: Zenith
Vlode/Number,ZTG 800 �Gj 5" �-o�;�j�'/ --(�7�sU�jS -�
S�rial Nurnber: !5��!!-- l -�
�
Manufacturer. � �_.
��
Vf.�del Number:
Serial Number.
Manufact�rer.
Vlodel Number:
. . .,-��..,Serla/Number.
Manufacturer•
wo��l Number. -.-� �
,S�►'ial Number.
Manufacturer:
Vlodel Number:
Serlal Number.
Page 1
i
� Initial lnstallation ond Prestart Checks
[� Sound:REA lN�3S�:>; Please Click Sound Readings tink to Aecess Eorm
_ , _
Fue/Sysfem
�Natural Gas �LPC Vapor ��PG Lipuid
Manua►shut Off valve
Primary Gas Pressure Regulator
Gas Volume Surge Tank
Dry Fuel Strafner
Flexl6le Fuel Connectlon
Gas Avalfable;_Water Column No Load,_Water Column Full-Load
�caso►!ne
Flexlble Fue!Connectlon Suppfy
Primer Tank(If Requiredl
Gasollne Available
Prlmed
lese/
Flexible el Connections fSupply and Returnl
o Engine �Supply rank �Day Tank
ase Tank
�Day Tank
Screen/FilterAssemblyAhead of Fuel lnlet
Fue!Tiansfer Pump and/or Solenoid Valve
Day Tank Float Switch Wlred to Fuel Transfer Pump(A.C. or D.C.1
ChecKValves on Engine
Fuel Return/Overffow Line to Main Tank One Size Larger than Supply
u evel below Injectors
fe uel Avallable
eed�lesel
Exhausf Sysiem
Flexible Exhaust Tubing
E ust Condensatfon Trap ��'r �d ��''C L"TG-
er
or Exhaust Ptping Size
ong-Radius Exhaust Elbows
Ex st Thlmble
a)n Cap/Beveled End with Screen
Page 2
Initial Instailation and Prestart Checks
Model:
E/echical Check Dui S/N:
AMPS:
Generator Maln Cfrcuft ereaker-Closed
Phase Rotatfon atATS
�Clockwlse Rotatlon(ABCJ �Counter Clockwise Rotation fACBJ
QATS Voltage set polnts
�UnderVoltage �e� � (�.�
BPick Up qo of Normal
Drop Out 3�0 of Plckup
�Over Voltage
BDrop Out 9�0 of Normal
Delay seconds
�Frequency Sensing at ATS
Plckup 9� of Normal
Delay seconds
Voltage
Hertz
Allow Proper No Load Warm Up
Starf up(Add load)
e or S�vltch In Run Positfon
dd Load by Load Bank-ff requfred
Automatic Stad
SetATS Tlme De�ays
RE-Check Oi!&Coolant Levels
Selector Sw)tch ln AUTO Operatfon Genset
ATS Linear Motor Swltch-On
Slmulate Power FaHure
IWtlHt�r Mafn Breaker or T.est Switch at the Autamatfc Transfer Sw1tGa1
Engine/Generato►
E e Start OK
e&Cen rator Under Load OK
O ess �Ibs
Temperature 1 Degrees
nusual Noises/Vibra fons
Page 5
I
Initial Installatlon and Prestart Checks
Model:
AutomoNc Load Transfer Swftch S/N: ,
Transfer to Emergency- OK
Remove Load(Maln Breaker or Test Swltch in the Auto Load Transfer Swftchl
Start Tlme Delay Seconds
Transfer Tlme Delay Seconds
Program Transitlon Time Delay seconds
Voltage
Hertz
Retum Load to Normal lMaln Breaker or Test Switchl
Re-Transfer Time Delay minutes
Program Transitlon Time Delay seconds
Re-Transfer to Normal OK
Cool Down Perlod minutes
Engine Shut-DOwn OK
Accessories
Supply Tank to Engine
Remote Annunclator Functional
Set Battery Charger Charging Rates
VDC Float VDC
VDC Epuallze VDC
�Exere ser Clock, Set tlme and day
�Set Exerclse Period
Flnal Insiai/aHon RecommendaHons
I
�
Page 6
� - I
i
.
Initial Installation and Presfart Checks
Onan Wonanly Inifiation
Engine/Generator-In ServJce Date: ri /��' �'�
Automatic Load Transfer Switch -In Servlce Date:
Check Out&Initia/Stari fJp
Performed By: �./�� Date: ���� ��
Performed By: Date:
Witnessed By: ���`����j��, Date: G � _
company: �.,,/C�. �EI�T-�-�-`�
Final Check
Engine Switch►n Remote Posltlon
Generator Field ereaker on
Transfer Sw/tch connected to Normal
Transfer Swftch!n Auto Posltion
Exerciser Clock Operatlonal
Insfrucfion Given To:
�Owner Date:
�Contractor Date:
�Other, Speclty Date:
Date:
Date:
Date:
�
I
Page 7
� _ -_ _ �
�
Generator Model and Control Information
Complete CeneratorSet Model and Spec. Number %���c, �7��=���G'f
Generator Serial Number_ I3��7v��i� ���
ControL• 100 ControL•
3?a0 Control:
3200 Controh.
other:
Where applipble Ilst generator control Informatfon.
Control calibratfon P/N: 3�� C/S�
Control checksum number:
List All Feature P/N�s: ��z-
..�°'���f
.S�f�
sS�. —
ss7�j
s3`J'7
5�r3
s��3
s 7Zz-
5��7
-- S7Sn
( /Sll'
I _ G /S�
�!(o/
Page 8
. � Industriai/ Generator Division
C u m m � n s 8213 East 96th Avenue • Henderson, CO 80640 I
R O C K Y M O U N T A 1 N L L C Phone: 303-287-0201 • 800-927-7201 Fax: 303-286-3776
Load Bank Test Results
^ �Job Name: r%�ic S �",�i•,.,.j oi2 Date: ��//C � 7
Contractor: �������`'-� �L��/a2.�� l ��
Power Factor:
^ � �
Model Number. ���i `�'J' 7�� /(d C.a� Hours Tested: �
Serial Number: !7��70 (lJ(�7 7 /� Performed By: ✓�r ��
Voltage Voltage Voltage Amps Amps Amps OIL Water Ambient
Time L1 L2 L3 L1 L2 L3 KW HZ PSI Temp Temp
a7� �'�� ��?�� �t�� �a U ��;v �v a 3.�� �o 't 1 /��
o��s �°4� ��, �v �fU�� �uv yau :� 3Z- �.,�� �r l��
��e�5 �� �f�J �l�v �f�/� ��o ��� �3d- w�' �I� !���
a�r 5 �f��l ��U ��c> �t�(� ��� �f�� 3 .,�.�1� �vc� �� ��,�_
G���f� �tZ� ��� �'°v `/uo ��� �fv� 3�3 �c; ��' l�7
!�r� y�v �� �f°� �av ��rc� �vv 33z !vv �� !u°�
���t� ��� ��c� �°u �u t� �fv� �fa�� 3� � �� �u7
1 I S ��`� �l�c� �f� o �� �vo d�ao �3� �o � f u�
l��.� ��� �fL�c� ��i1 �oU ��v ���1 �.3y l�v ��i ���
Comments:
Customer Signature: Date:
llL�U/ 1 //�UUI/N1U1V U(; �( R1V1 IV4Vl�l.�Vla rnr. iv�, �iuzwi�uu • � ���
A,�� ��.A"'S
r�l.'4.y, r�.<:.: >:,� ' ':,
.�` �
.r�j' ���F: �i�'a o�ee'°'b,?e .i� ?�e...•.
�! .pF�'3�` •.
�'OU#•'fClt O�MGOV�RNJr� T�°%Rf• ` { � �' ��, ��.'S .�4 � § k � � s .
's. a.a..• a:G € , s ' : s .� # '}� €
rs`�;�.e;. t'.«�x;_�e.x; .. ,:'S ,r' S �'" 3 � . x 4 . .
r , �� ���i Da >: � . �' . 3 i
' �_:.��`�.s�Ca•%' a . � . i ; � � '£ 3 � ..Y' i� u ' .
. ta`� ,
Tv: Charlie�Davis,Town c►f Vail, Building Offic�l
F�oma Mike StewsrC, Lead �levabar Inspecfar
970-468-0295 ext. 108 or elev�tor@nwc:eog.co.us .
Da�: �.z/�.7/2007
Praject Name: Vail's Front Daor Elevat�ar#C1 Perimit# BQ�-0020
❑ Elevator Plan Review
�� �feva�tar T�esX and Inspection
Locatian: 151 Vail Lane, Vail, Co. � �
Permit Number: NWCCOG 07�218 � :
Elevator Type: Hydraulic Passenger
❑ The pl�ns; have been reviewed and found to confnrm to �II �ppficable ASME 17.�. and
IBC codes.
[�-'� The rated speed of the conveyance meets ASME A17.1 requiremerrts, speed in up
direction 200 FPM, speed in down direction Z00 FPM
C�''r Th� E(eva�r at the above location was inspect�ec! and tes�ed on 12/14/2007 and a:
0 TEMPORARY Cerfificafie; has been issued.
��-FZNAL Inspection Certif[cate; has be�n issued.
. . . �❑ Nt3 Certifica't,�; is t�eing issuecl.
❑ FOFL CONSTRUCI�ON USE C7NLY � �
Comments:
Elevator annunciatar panel still needs to be instatled in the Fire Command Room � •
Label aIl eleva�or landing�ambs tio indiCate its id�ntif��ion number; Ci, D�, D4, D21, DZ2
Signature �
Northwest Colorado Council af Govemments i P4 8ax 2308 + Silverthorne • CO ♦ 80498
970�68-0295 � F�x 97�-4E$-'I208 ♦ www.�wacag.co.us �
�.a,��
� G�
DEC/17/2007/MON 07: 57 AM N�CCOG FAX No, 9704681208 P. 002
�s .<.
-°�
���...
r'»: o.,
r�: �y�*� ;��4�.��`` `�•_
,s�� i, ' i, : , y��:'•.r .
` , , • • ��;,4 . � , { , .
.fe'�U�7'Cll OF�,.GOY$r��N+1��I��^"� , {� � ' # ,�, Q 1 p , � � .
6" R f � , . ; a e t � �k
ri'R.n;° f,��'�rlsz`:^�`s'�' � '#� � 4 �Ie � e
, . ���}�° `a,� ' Y : ..G : .r $ }.� : y • ... � �' .� .
• `�iri� .
To: Ck�arlie Davis,Town of Vail, Building C�ffiaal .
From. Mike Stew�rt, Lead EEevator�Tnspector � �
970-�68-OZ95 ext. 108�or et�rrator�nwc.cag.co.us
17�ioe; 12/17/2007
Project Name: Vai['� Front Daor Elevai�ar# �3 Pennit# BOG-��i
❑ Elevat�ar Plan Review
�� Elevator Test and Inspeckion .
Lacation: 15i Vail Lane, Vail, Ca. � � , : . �
Permit Number: NWCCOG 07�-137 � �
Elevafior Type: Hydraulic passenger �
❑ The plans; have been reviewed ar�d found to conform to all applicable ASM� 17.�. and
. IBC codes. � . ��
C��The rated speed of the conveyance meets ASME A�,7.1 requiremenfs, speed in up
dir•ecction 150 FPM, speed in dawn directiQn 150 .FPNi
��The �levator at the above locationk was inspectecl and tested an 12j14/2pQ7 and a:
❑ TEMP4RARY Cert+ficabe; has been i5sued.
L��FINAL Tnspection Certificate; has been issued.
CI NO �ertifi�te; is being issued. � . �
� FOR CONSTRUCTION l�S� OI��Y ,
Comments:
El�vator annunciator panel still needs to f�e instal[ed in tYie Fire Command R�oom �
Lab�l �f1 elev'atior landing jambs to indicate its identificafion number: C1, D3, D4, D21, D2,Z
Signature
Northwest Colarddo Council of Gavemmac�ts + PO Box 2308 �� Silverthome + CO � 8Q488
. 970-468=0295 a Fax 970-46�1208 ♦ www.nwacog.co.us � .
DEC/17/2007/MON 07: 57 AM N�CCOG FAX No, 9704681208 P. 003
,�° .;�,�..
,��;.,, ,::�„"�" �>
.�� ,<„�,,_,. ..�•.
r- , �;, e ka� • �•• ��.vc,Y
,�j s. �t�:.`�1.'i' c• . 1:fd`'+� } ..
.�',� s . .� ry y t� f R
I:'PIF�C�I PF i�OV�,NM$ T$"' � ` ~ i y •, 3 � � � �i ,PS i
�'�% a.s f� . ' 3 y 'i s � � � f
.�»�ar>: !i�;ta�R'ew�'�`�..° !�l � : , ! � s : i
Y € � '� � � ',y' � s
:���9 p•'A � � ... �.; . , r �
���% .
To: Chariie Davis,Town af Vaff, Building Officia!
From: Mike Stewart, Lead EEevatior In�pector
970-968-�295 ext. 108 or elevator@nwc.cog,co.us � .
[?ate� 12/17/2007 • . . : �'
projecC Name: Vail's Fr�on�Daor Eleva�oE-�f' D4 �'mi��# B�G-00?�. � �
❑ Elevat�or Plan Review . � �
Ca�''r Elevabor Tes�and Tnspecrion
� Loea�on: 151 Vail.Lane, Vail, Co. �
Permit Number. NWCCOG 07-138
Eleva�or Type: Hydraulic Passenger
❑ The plans; have been reviewed and found to conform t� all applicabl�ASME �.7.1 and
I�C cc�des.
p�� The ra�d speed ofi the �onve�r�nc� m�ts ASME A17.7, requirements, speed in up � •
direction 15� �PM, speed in dawn direcbion 150 FPM . . . �
C�"'�The Elevator at the above locadon was inspected and tested on 1�/14/2007 and a:
d T�MPQRARY Certificate; has been issued.
�r FiNAL Inspec�on Cerfificate; has been issued. .
❑ NO certificate; is being issuecl. �
� CI FOR CONSTRCJC[�ON U5� �NLY
Camments: .
E[evabor annunaator panel still needs to be installed in �he Fire Command Room
Label af� elevator landing jambs to indicate its identifiptian�number: Ci, D3, D4, D21, D22 �
Signature
Northwesfi Colorado Couneil of Gavernmenfs � PO Bax 2308 ♦ Silverthorne ♦ CO ♦ 80498
970-468-�295 � FaX970-468-1208 ♦ www.nwc.cag.co.us
DEC/17/2007/MON 07; 57 AM N�CCOG FAX No, 9704681208 P. 004
3<: ���= m.
,<s� .<�i`�� '� ��.
.ti. ,�.¢.
> Wi. J��Y.lS,' �eA� �'Z
f'°,: < .1 �le: .u'; y r fy lr�� .
s,'u �; �'`4 •r.p,r.', '�y
,��'OU7�iCll O�x,.C�dV�tNM•� TS,%• �, } s k � .'t ' � ; � .
.:�'.'��� 'a'� . 'e .', R .� � '>;
���t"c>' ' �'�,a=�l;�> >l' � � 1i �: �p � � .
�y��,,��,� � f . .b � � '9 � + i 3 ; .
. •i.�y:.xi . . .... „,
To: Gh�r[ie�D�vis,Town of V�il, Building Of�ida!
From: Mike 5tewart, Lead Elevator Inspector
970-468-4295 �. �DS or el�vator@nwc.cog.CO.us
a�: iz/i7/2oo� �
P�roye.cC Name: Vail's Fr+ont Door Eleva�or# DZ�. Pe�'mi�# B�6-OQ21 �
❑ E(evatar Plan Review - �
. CC�� �levatpr Test�r�d Inspe[.tion .
Location: 151 Vail Lane, Vail, Co. . � � �
P�rmit Number: NWCCOG 07--103
Elevator Type: Hydraulic Passenger
❑ lt�e plans; have been reviewed and found to confarm �ko all applicable ASME 17.1 and
IBC codes. .
C��The rated speed of the cor�vveyance meets ASM�A17.1 requirements, speed ir� up
� direction 110 FPM, speed in down directian 110 FPM
[�� The Elevator at the abave Iocation was in�pected and tested an 12/14/7A07 and a:
❑ � T�MPORARY Cerfi�cabe; has been issued. -
�� FINAL Znspection Certi�cate; has been issued.
❑ NO certificate; is being issued. �
❑ FQR CQNSTRUCTION IJSE ONLY
Comments:
Elevator annunaatior panel still needs to be installed in t�e Fire Command Raom �
Label a!I elevator landing jambs to indicate its identifica�"ron number: C1, D3, p4, D21, D22
Stgna�ure
Northwest Colorado Council of GoverrrmeMs + PO Box 2308 � •Silverthome w Ga + 804�98
970-46&0285 + F�c 970-�4B8-1208 a wvow_nwc.cog.ca.us
DEC/17/2007/MON 07: 57 AM N�CCOG FAX No. 9704681208 P, 005
. � ,�1�L
� �1
..ei"wK� .d' o.fe''� �,
''g� �. •:K.•.�{' ' sQ.
� • �" .�sk�iS•�� . !'�. •. ` ' . '. <
t . , 3 3 " ; �
. . �QiP1VCll OF�OYE,RH� T��v ; i. � �' e S � � L � i
..�'�i�"t !°a!'r`_X r } r••n i; � � � � ' '� `s
.�n',or�L ,wo�f��S4?�ua�=x� o : i :. � � ¢ p� s
� ' ,wn.&�d:ii%'� s �. . 's l�d ° . � ♦ � . . . ,C� � �''
A
Tb: Charlie�Davis,Town of Vai[, Buifding Official
From: Mike Stewart, I�ad Elevator Znspe�tar
970-•468-�0295 e�. 108 or eleva�ar�nwc.cag.co.us
Dabe� 12/17/2007 � � • .
Project Name: V�i1's Frvnt Door Elev�to�'# M7�2 Permit# 606-002� .
❑ Elevator Plan Review
0� .Elev�tor Test and.Inspec�ion.. _.. .. .. .. _ _. . . .. .. . .. .
� Location: iS'i Vail Lane, Vail, Co.
Permit Number: NWCCQG 07-105 �
, Eleva�r Type: Hydraulic Passeng�r �
❑ The plans; have �een reviewed and found to conform to alI applicable ASME 17.1 and
z�c cactes. .
��The rated speed of the conveyance meets ASME A17.1 requirements, speed 1n up, �
direcEion 110 FPM, speec� in down dire�ction 110 FPM � . '
C�� The Elevator at the above lacatian was inspected ar�d tested on 12,/14/2Q07 and a:
❑ TEMPORARY Certi�icate; has been issued.
C�---�FINAL Tnspectian Certif�ca�; has been issued.
� NO certificate; is being issue�i. .
❑ FOR C4NSTRUCT�4N US� ONLY
Comments:
Elevator annunciator panel still needs to be ins�ailed in the Fire Command Raom
l.abel all elevatior ianding j�rnbs to indicat+e its identification number: Ci, b3, D4, DZ1, D22 �
Signature . .
NortY�west Calorado Council of Govemmr�nts ♦ PO Bax 2308 ♦ Silverthame ♦ CO � 80495
. 970-468-0295 * Fax970-46&1208 � vwvw.nwc.cag.co.us
Vail, Colorado
Denver, Colorado
Frisco, Colorad��
Monroe 8� Newell
Engineers, Inc.
November 12, 2007
Town of Vail
75 So. Frontage Road
Vail, CO 81657
Attn: Mr. Charlie Davis, Chief Building Official
Re: Vail's Front Door Building A—
Parking Ga.rage and Loading Dock (M&N#5500)
Dear Mr. Davis:
Monroe &Newell Engineers, Inc. observed the foundations, structural framing, and other
struciural items during construction.
To the best of our knowledge and belief,based on our limited visual observations and the
information provided us,the foundations, structural framing, and other structural items
are constructed substantially in compliance with the intent of the construction documents
as approved by the Town of Vail Building Department.
If you have any questions or comments,please call.
Very trul�y�yours,
,�,���W�p��t�����".�°'���,
M �'i"� �L ENGINEERS, INC.
d.
��� �� `°1'{��� . . ... ,, ,
f� �a �.
�^�s
��,. .,$ �
s��, /�6(9• 00(, s
fi � �a
�n� e ..
Pe���� ���� �,1'E.
��. �° .
Princip�l`"�,
Cc: Randy Hart, 4240 Architecture
Rick Caudel, Vail Resorts Development Company
A 2007 Platinum Corporate Sponsorof
��� � � Colorado
A Canponent of The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
(iO3) 623-4927 • FAX (303) 623-6602 • email: denverC�monroe-newelLc<�m
� s .
..`
�/y�_�j� �0� �����
������ �o�� Marc E.Espinosa
David B.Robinson,P.E.
\ Richard D.Matthies,P.E.
FNCivFt:ai�c.,inc.� Stephen C.Rondinelli,AIA
,,�,,,�;�=r,�,�,�,�:,;�r���-�,;,��„�,>>,a Robert M."Mike"Cordero,P.E.
g�(o - oe��-�
November 19, 2007
Mr. Charlie Davis,Chief Building Official
Town of Vail,Community Development
Email: CDavis@vailgov.com
Chief Mike McGee,Deputy Chief
Town of Vail,Department of Fire and Emergency Services
Email: MMcGee@vailgov.com
Mr.Matt Royer,Building Official
Safebuilt—Consulting Building Inspection and Plan Review
Email: Matt.Rover@safebuilt.com
Re: Clarification of Elevator Status/Annunciation Request for Vail Front Door Fire Command Room
Over the past few weeks there have been numerous discussions and emails regarding the request for
elevator status/annunciation for the Fire Command Room in Building C of Vail's Front Door.These
discussions have included the Town of Vail Building and Fire Department, as well as the Northern
Regional Council of Governments Elevator Inspector and various members of the design team and
contractor. Some of the discussions included the specific items listed in the May 15, 2006 Memorandum
of Understanding that was submitted and approved by the Town of Vail,that are being provided in the
Fire Command Room in Building C,in addition to the requested elevator status/annunciation panel.The
design team and contractor are currently proceeding with the design and addition of the requested elevator
status/annunciation panel far the elevators in Building A,C and D. Building E(Chalets)will have a
separate Fire Command Room and those elevators will be provided with an elevator status/annunciation
panel for the elevators in Building E only and will not be connected to the Fire Command Room in
Building C.
Since this issue may not have been been described in the Memarandum of Understanding as currently
approved,I felt it necessary to provide this document to clarify the original request and the purpose of the
performance based approach requiring the Fire Command Room,the components specifically listed in
that document and lastly, clarify the request.
Based on these discussions I felt the need to restate the original intent of the Memorandum of
Understanding and to clarify in this document the extent of the elevator/annunciation being proposed for
the Vail's Front Door Project and the components that are intended to be installed in the Fire Command
Rooms in Building C and Building E.
To assist the reader in request for clarification Pve excerpted pertinent sections of the May 15, 2006
Memorandum of Understanding(the submitted Memorandum of Understanding is attached for your
reference). The excerpted sections are indicated in italic text.
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•Fnx: 303-422-7900
� ,i
MEMORANDUM OF UNDERSTANDING REpUEST
Vail Front Door Project
Vail, Colorado
Modi�ed Mav 15,2006
April 3, 2006
VAIL FRONT DOOR— VAIL, COLORADO
1. SMOKE MANAGEMENT SYSTEM(STAIR and ELEVATOR HOISTWf1 Y)
2. FIRE COMMAND ROOM
3. USE OF ASSUMED PROPERTY LINES AND FIRE SEPARATION
4. USE OF 508.2 FOR CREATING SEPARATE BUILIDNGS
5. ACCESSIBILITY REQUIREMENTS IN RESIDENTIAL CHALETS
6. DOOR OPENINGS INTO SKI CLUB EXIT ENCLOSURE
This document supersedes all previouslv submitted�re protection and life safety documents related to the
Vail Front Door Project. Previous documents produced bv Rolf Jensen and Associates, Inc. (RJA)will
not be in effect. Effective March 11, 2006 BCER Engineering,Inc. BCER)will be the fire protection and
life safety consulting engineers of record for the pro'7ect•
INTRODUCTION
This Memorandum of Understanding(MOU) request is the documentation of several meetings and
discussions with the Town of Vail Building and Fire Department. The intent of this correspondence is to
"document" how the design team will comply with the requirements of the adopted building,fire code
and amendments as adopted by the Town of Vail. This document differs from the Request for
Administrative Modification process in that we are not requesting any variance from the adopted building
and fire codes. This document should be a reference to and complement the Life Safety Report and
Construction Documents prepared by the design team.
1. SMOKE MANAGEMENT SYSTEM(STAIR AND ELEVATOR HOISTWAY)
The buildinn is not considered a high-rise structure, however, meetinQS with the TOV Fire
Department identified that f re department access was limited and that performance based
approach was taken for this complex. This required a smoke management system to augment the
fire department access. The smoke management system will include the pressurization of Stair
#CS01 and Elevator#1 in Building C. Buildin� C is the Alpine(SKI)Building located in the
center of the Vail Front Door Complex. This stair and elevator will provide access to all levels of
the complex. The stairs and elevator are located near the fire command room and the fire
department staQing area on the exterior of the buildin�
• Stairwell Enclosures—The smoke management svstem for the desiQnated stairwell
enclosure will consist of a pressurization fan for the designated stairwell will be
activated automatically upon fire alarm activation(water-flow or detection). The svstem
will be desiQned such that durin�peration the doors into the stairwell will not require
more than 30-pounds of force to open, reQardless of the barometric pressures of the
environment. We discussed that the system will not need to be designed to any minimum
pressure differential such as 0.05 inches of water column but it would be enou�h to keep
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION ll.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838•TE�EPHONE: 303-422-7400•FAx: 303-422-7900
[
the stairwell positive in relation to adjacent spaces A smoke manaQement system will to
be desiQned bv a fire protection enQineer and submitted to the�re department for their
review and ap rp oval•
• Elevator Hoist-wav—The smoke manaQement s sy tem for the desi nated elevator hoist-
wavs will consist of a pressurization fan for the elevator shafts activated upon fire alarm
activation (water-flow or detection). The smoke management svstem will not need to be
desi ned to an minimum ressure di erential. However the s stem will be desi ned to
keep the elevator positive in relation to the adjacent spaces or elevator lobbies The
positive pressure will extend bevond the hoist-wav into the elevator lobbies or adjacent
corridors. It is intended that the smoke manaQement system will prevent smoke from
miQratinQ from floor to floor via the identified elevator hoist-way or stair enclosure
• EmerQencv Power and Control—The smoke management system will be connected to
the buildinQ emergenc� op wer svstem since this is a life safetv system The smoke
manaQement svstem will also be manually controlled from the�ire command center
utilizing an approved smoke control panel
2. FIRE COMMAND ROOM
At numerous meetinQS with the TOV fire department the design team nresented the�re
department access and the location of the fire command room The TOV fire denartment agreed
the buildinQ was not a hi�h-rise but requested that a�re command be provided It was agreed to
by the team that the fire command center would be located near the entrance o BuildinQ C or the
Alpine(SKI) Club near the main entrance Further clarification from the fire department also
required that the fire command room would not be shared with anv other function and would
require direct access to the exterior via the stair enclosure The currentl�pproved location
�rovides a central response point for the cre department sta in,�area with access to stairs
servinQ the buildinQ and an elevator servinQ all levels of the building complex The fire command
room location has been anproved and also communicates to the stair enclosure AlthouQh a
normallv non-occupied room cannot communicate to a stair enclosure the access from the
exterior into the stair enclosure is a desirable condition and acceptable to the fire department
Listed below are the components that will be included in the fire command room•
• Annunciation Panel for the fire alarm svstem
• Fire Fighter Smoke Control Panel
• Public address, voice communication svstem status and controls
� A direct dial tele hone.
• A table for reviewing building plans and schematic dia rams
• Schematic building plans including typical floor lans egress drawings fire protection
�stems, smoke control diagrams fire-fighting ec�uipment and fire department access
• Kevs to access all portions of the buildi�
Items#3-6 have not been included in the request for clarification but can be referenced in the attached
Memorandum of Understanding.
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION ll.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•F,ax: 303-422-7900
In the preparation of the original Memorandum of Understanding,the use of code required terms and list
of items provided in that document were very specific and deliberate.The use of the terms Smoke
Management System and Fire Command Room were specific to this project as well as others where
BCER is the designated Fire Protection Engineer of Record.The term Smoke Management System was
used in lieu of the IBC defined term for a Smoke Control System as well as Fire Command Room in lieu
of Fire Command Center.These terms are clearly defined in the International Building and Fire Code and
have clearly defined requirements. It has always been the intent of the design team and project that since
Vail's Front Door was not a high-rise building but,did have some compromised fire department access,
the requirements for the Smoke Management System and the Fire Command Room were to be described
through the Administrative Modification and Memorandum of Understanding process.We are not
requesting any clarification for the Smoke Management System.With respect to the Fire Command
Room, I feel it important to re-discuss the intent of the Fire Command Room as compared to the Fire
Command Center.
A Fire Command Center is typically found in high-rise buildings. Fire ground operations usually involve
establishing an incident command post where the fire fighter can observe what is happening,control
arriving personnel and equipment,and direct resources and fire fire-fighting operations effectively.
Because of the difficulties of controlling a fire in a high-rise building, a separate room within the building
is provided at a locarion acceptable to the fire department.That room is usually located along the front of
the building near a main entrance.The room contains equipment necessary to monitor and control
building service systems.Below is a list of the items in IBC Section 911. Beside each item I've indicated
if the Vail's Front Door Project was intending to provide the equipment listed.
Required Equipment for Fire Command Centers in Equipment being provided by the May 15, 2006
accordance with Section 911 of the 2003 Memorandum of Understanding. (Clarification of
International Building Code Equipment being provided as of November 19,
2007).
Emergency Voice/Alarm Communication System Provided per MOU-Fire Alarm System has Voice
Unit Alarm/Paging Capability and is controlled from the
Fire Command Room for Building A,C and D.
Building E(Chalets)has a separate system for
those buildings and is controlled from the Building
E Fire Command Room.
Fire Department Communications Unit Provided per MOU—Fire Alarm System has FD
Communication capability and an Emergency
Radio Enhancement System is being provide.
Annunciation unit visually indicating the location Not Provided in MOU—Added based on request
of the elevators and whether they are operational from the TOV Building and Fire Department.
(Design team is proceeding with providing an
elevator status/annunciation panel for Building A,
part of B, C and D,including elevators C1,C5,D3,
D4,D20,D21, B2 and B6. BCER re uests
consideration that onlv the elevator status be
provided for Building C which would be Elevators
C1 and C5. Building E(Chalets)will also have an
elevator status/annunciation panel for the elevators
in that building and will not be connected to the
Building C Fire Command Room).
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION 1119.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838•TELEPHONE: 303-422-7400•Fax: 303-422-7900
Status indicators and controls for air handling Specifically excluded in MOU and not provided in
systems. the Fire Command Room based on this
clarification.
Fire-fighters control panel required by section Provided per MOU as part of the Smoke
909.16 for `smoke control systems' installed in the Management System.
buildin
Control for unlocking stairway doors Specifically excluded in MOU and not provided in
simultaneously the Fire Command Room based on this
clarification.
Sprinkler valve and water-flow detector display Provided per MOU as part of the Fire Alarm
panels System Annunciation
Telephone for fire department use with controlled Provided per MOU.
access to the ublic tele hone s stem
Fire pump status indicator Fire pump not required for this building.
Specifically excluded in MOU and not provided in
the Fire Command Room based on this
clarification.
Schematic building plans indicating typical floor Provided per MOU.
plan and detailing the building core,means of
egress,fire protection systems,fire-fighting
e ui ment and fire de artment access.
Worktable Provided per MOU.
Generator supervision devices,manual start and Specifically excluded in MOU and not provided in
transfer features. the Fire Command Room based on this
clarification.
Public address system where specifically required Provided per MOU-Fire Alarm System has Voice
by this code. Alarm/Paging Capability and is controlled from the
Fire Command Room for Building A,C and D.
Building E(Chalets)has a separate system for
those buildings and is controlled from the Building
E Fire Command Room.
Based on this Request for Clarification, BCER is requesting that the Fire Command Room in Building C
and E be provided with the equipment listed above per the May 15, 2006 Memorandum of
Understanding. For clarification BCER is also reyuesting that an Elevator Status/Annunciation Panel in
the Building C Fire Command Room be provided for Elevators C1 and CS only. In Building E an
Elevator Status/Annunciation Panel for each of the elevators in Chalets will also be provided. No other
equipment as listed above from Section 911 of the IBC is being proposed for inclusion in either of the
Fire Command Rooms.
Due to the current project schedule for completion and anticipated occupancy later this month(or early
December 2007)we would request your concurrence of this clarification by signature of the document
below.We are anticipating that the components listed above will in place and operational for the issuance
of at least a Temporary Certificate of Occupancy for Building C. However,due to the time needed to
design,produce and install the elevator status/annunciation panel in the Building C Fire Command Room,
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION 1119.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,CO�ORADO 80002-1838•TE�EPHONE: 303-422-7400•FAx: 303-422-7900
there may be a request for a mutually agreed upon time frame for the installation of the panel.Please call
if you have any questions regarding this request and contents of the document.
Prepared by:
BCER Engineering,Inc.
Stephen Rondinelli,AIA
Principal,Director of Fire Protection and Life Safety
�-1PP VE /
,
� f �
; ,.
, � ,- � �,
,+ ,�% '/,�: _ i- `
_ r� i l �U !J'� ;�:�'�--�'r--�-- �i%i��%-'`�`--�,
TUV �UIILDING I7EPARTMENT/DATE TOV FIl2E DEPARTMENT/DATE
C:IDOCUMENTS AND SET"TINGS\SCR�DESKTOP�BCER VFD FII2E COMMAND ROOM CLARIFICATTON ll.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,(',OLORADO 80002-1838•TELEPHONE: 303-422-7400�FAX: 303-422-7900
r�
'�'i3A?i't ���1�
�yT7-�
� Marc E.Espinosa
� David B.Robinson,P.E.
� Richard D.Matthies,P.E.
ervci:�Fett��c,inc. Stephen C.Rondinelli,AIA
,,:r.,;.,=r,,,,r,,,,,,,,�,�t::,,,;,;;,,,,,, Robert M."Mike"Cordero,P.E.
��� - oc���
November 19, 2007
Mr. Charlie Davis,Chief Building Official
Town of Vail,Community Development
Email: CDavis@vailgov.com
Chief Mike McGee,Deputy Chief
Town of Vail,Department of Fire and Emergency Services
Email: MMcGee@vail ov.com
Mr.Matt Royer,Building Official
Safebuilt—Consulting Building Inspection and Plan Review
Email: Matt.Rover@safebuilt.com
Re: Clarification of Elevator Status/Annunciation Request for Vail Front Door Fire Command Room
Over the past few weeks there have been numerous discussions and emails regarding the request for
elevator status/annunciation for the Fire Command Room in Building C of Vail's Front Door.These
discussions have included the Town of Vail Building and Fire Department, as well as the Northern
Regional Council of Governments Elevator Inspector and various members of the design team and
contractor. Some of the discussions included the specific items listed in the May 15,2006 Memorandum
of Understanding that was submitted and approved by the Town of Vail,that are being provided in the
Fire Command Room in Building C,in addition to the requested elevator status/annunciation panel.The
design team and contractor are currently proceeding with the design and addition of the requested elevator
status/annunciation panel for the elevators in Building A,C and D. Building E(Chalets)will have a
separate Fire Command Room and those elevators will be provided with an elevator status/annunciation
panel for the elevators in Building E only and will not be connected to the Fire Command Room in
Building C.
Since this issue may not have been been described in the Memorandum of Understanding as currently
approved,I felt it necessary to provide this document to clarify the original request and the purpose of the
performance based approach requiring the Fire Command Room,the components specifically listed in
that document and lastly,clarify the request.
Based on these discussions I felt the need to restate the original intent of the Memorandum of
Understanding and to clarify in this document the extent of the elevator/annunciation being proposed for
the Vail's Front Door Project and the components that are intended to be installed in the Fire Command
Rooms in Building C and Building E.
To assist the reader in request for clarification I've excerpted pertinent sections of the May 15, 2006
Memorandum of Understanding(the submitted Memorandum of Understanding is attached for your
reference). The excerpted sections are indicated in italic text.
C:�DOCUMENTS AND SETTINGS\SCR�DE3KTOP�BCER VFD FII2E COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD f�OAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•FAx: 303-422-7900
t
MEMORANDUM OF UNDERSTANDING REOUEST
Vail Front Door Project
Vail, Colorado
Modi�ed Mav I5,2006
April 3, 2006
VAIL FRONT DOOR— VAIL, COLORADO
1. SMOKE MANAGEMENT SYSTEM(STAIR and ELEVATOR HOISTWAY)
2. FIRE COMMAND ROOM
3. USE OF ASSUMED PROPERTY LINES AND FIRE SEPARATION
4. USE OF 508.2 FOR CREATING SEPARATE B UILIDNGS
5. ACCESSIBILITY REQUIREMENTS IN RESIDENTIAL CHALETS
6. DOOR OPENINGS INTO SKI CLUB EXIT ENCLOSURE
This document supersedes all previously submitted fire protection and life safety documents related to the
Vail Front Door Project. Previous documentsproduced bv Rolf Jensen and Associates, Inc. (RJA)will
not be i►z e�'ect. Effective March 11, 2006 BCER E�igineering, Inc. (BCER)will be the�ire protection and
li e safety consulting enRineers of record for the project.
INTRODUCTION
This Memorandum of Understanding(MOU)request is the documentatiort of several meetings and
discussions with the Town of Vail Building and Fire Department. The intent of tl�is correspondence is to
"document" how the design team will comply wit12 the requirements of the adopted building,fire code
and amendments as adopted by the Town of Vail. This document differs from the Request for
Administrative Modification process in that we are not requesting any variance from the adopted building
and fire codes. This document should be a reference to and complement the Life Safety Report and
Construction Documents prepared by the design team.
1. SMOKE MANAGEMENT SYSTEM(STAIR AND ELEVATOR HOISTWAY)
The buildinQ is not considered a high-rise structure, however, meetings with the TOV Fire
Department identi aed that fire department access was limited and that performance based
approach was taken for this complex. This reguired a smoke management svstem to au,�ment the
fire department access. The smoke manaQe�nent svstem will include the pressurization o Stair
#CS01 and Elevator#1 in Building C. BuildinQ C is the Alpine (SKI)Buildinglocated in the
center of the Vail Front Door Complex. This stair and elevator will provide access to all levels o�'
the complex. The stairs and elevator are located near the fire command room and the fire
department staging area on the exterior of the building
• Stairwell Enclosures—The smoke manaQement svstem for the designated stairwell
enclosure will consist of a pressurization fan for the designated stairwell will be
activated automatically upon fire alarm activation(water-flow or detection). The system
will be designed such that duri�operation the doors into the stairwell will not require
more than 30-pounds of force to open, regardless of the barometric pressures of the
environment. We discussed that the system will not need to be desiQned to any minimum
pressure differential such as 0.05 inches of water column but it would be enough to kee�
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD ROAD,SUITE 200,AFiVADA,COLORADO 80002-1838�TE�EPHONE: 303-422-7400•FAx: 303-422-7900
,
the stairwell positive in relatio�2 to adjacent spaces A smoke manaQement svstem will to
be desiQned bv a�re protection engineer and submitted to the fire department for their
review and ap roval.
• Elevator Hoist-wav—The smoke management svstem for tlie designated elevator hoist
wavs will consist of a pressurization�'an for the elevator shafts activated upon fire alarm
activation(water-flow or detection) The smoke manaQement svstem will not need to be
desi�ned to any minimum vressure di fferential However the system will be desi n�
keen the elevator positive in relation to the adjacent snaces or elevator lobbies The
positive pressure will extend beyond the hoist-wav into the elevator lobbies or ad'a7 cent
corridors. It is intended that the srnoke management svstem will prevent smoke from
miQratinQ from floor to floor via the identified elevator hoist-way or stair enclosure
• Emer�encv Power and Control—The smoke management system will be connected to
the buildinz enzer�encv power system since this is a life safet�system The smoke
mananement svstem will also be manually controlled from the fire command center
utilizinQ an approved smoke control panel
2. FIRE COMMAND ROOM
At numerous meetin.es with the TOV fire department the design team nresented the�re
devart�nent access and the location of the fire command room The TOV fire denartment agreed
the buildann was not a hiQh-rise but reguested that a fire command be�rovided It was aQreed to
by the teanz that the fire command center would be located near the entrance ofBuildin� C or the
Alptne(SKI) Club near the main entrance Further clarifccation from the fire department also
repuired that the fire command room would not be shared with anv other function and would
require direct access to the exterior via the stair enclosure The currentl�approved location
provides a central resvonse point for the fire department staeing area with access to stairs
servinQ the buildinQ and an elevator serving all levels of the building complex The fire command
room location has been anproved and also communicates to the stair enclosure Although a
normallv non-occupied room cannot communicate to a stair enclosure the access from the
exterior into the stair enclosure is a desirable conditio�i and acceptable to the fire department
Lasted below are the components that will be included in the�re command room•
• Annunciation Panel for the fire alarm s stem
• Fire Fighter Smoke Control Panel
� Public address, voice communication svstem status and controls
• A direct dial tele hone.
• A table for reviewing building plans and schematic diagrams
• Schematic buildinQ plans includin�typical floor lans egress drawingsz fire protection
systems, smoke control diagrams fire-fightin e uipment and fire department access
• Kevs to access all portions of the building
Items#3-6 have not been included in the request for clarification but can be referenced in the attached
Memorandum of Understanding.
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIItE COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400�FAX: 303-422-7900
1
In the preparation of the original Memorandum of Understanding,the use of code required terms and list
of items provided in that document were very specific and deliberate.The use of the terms Smoke
Management System and Fire Command Room were specific to this project as well as others where
BCER is the designated Fire Protection Engineer of Record.The term Smoke Management System was
used in lieu of the IBC defined term for a Smoke Control System as well as Fire Command Room in lieu
of Fire Command Center.These terms are clearly defined in the International Building and Fire Code and
have clearly defined requirements. It has always been the intent of the design team and project that since
Vail's Front Door was not a high-rise building but,did have some compromised fire department access,
the requirements for the Smoke Management System and the Fire Command Room were to be described
through the Administrative Modification and Memorandum of Understanding process.We are not
requesting any clarification for the Smoke Management System. With respect to the Fire Command
Room, I feel it important to re-discuss the intent of the Fire Command Room as compared to the Fire
Command Center.
A Fire Command Center is typically found in high-rise buildings. Fire ground operations usually involve
establishing an incident command post where the fire fighter can observe what is happening,control
amving personnel and equipment,and direct resources and fire fire-fighting operations effectively.
Because of the difficulties of controlling a fire in a high-rise building, a separate room within the building
is provided at a location acceptable to the fire department. That room is usually located along the front of
the building near a main entrance.The room contains equipment necessary to monitor and control
building service systems. Below is a list of the items in IBC Section 911. Beside each item I've indicated
if the Vail's Front Door Project was intending to provide the equipment listed.
Required Equipment for Fire Command Centers in Equipment being provided by the May 15,2006
accordance with Section 911 of the 2003 Memorandum of Understanding. (Clarification of
International Building Code Equipment being provided as of November 19,
2007).
Emergency Voice/Alarm Communication System Provided per MOU-Fire Alarm System has Voice
Unit Alarm/Paging Capability and is controlled from the
Fire Command Room for Building A,C and D.
Building E(Chalets)has a separate system for
those buildings and is controlled from the Building
E Fire Command Room.
Fire Department Communications Unit Provided per MOU—Fire Alarm System has FD
Communication capability and an Emergency
Radio Enhancement System is being provide.
Annunciation unit visually indicating the location Not Provided in MOU—Added based on request
of the elevators and whether they are operational from the TOV Building and Fire Department.
(Design team is proceeding with providing an
elevator status/annunciation panel for Building A,
part of B,C and D,including elevators C1,C5, D3,
D4,D20,D21,B2 and B6.BCER requests
consideration that onlv the elevator status be
provided for Building C which would be Elevators
C1 and C5. Building E(Chalets)will also have an
elevator status/annunciation panel for the elevators
in that building and will not be connected to the
Building C Fire Command Room).
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FIl2E COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•FAx: 303-422-7900
1
Status indicators and controls for air handling Specifically excluded in MOU and not provided in
systems. the Fire Command Room based on this
clarification.
Fire-fighters control panel required by section Provided per MOU as part of the Smoke
909.16 for `smoke control systems' installed in the Management System.
buildin
Control for unlocking stairway doors Specifically excluded in MOU and not provided in
simultaneously the Fire Command Room based on this
clarification.
Sprinkler valve and water-flow detector display Provided per MOU as part of the Fire Alarm
panels System Annunciation
Telephone for fire department use with controlled Provided per MOU.
access to the ublic tele hone s stem
Fire pump status indicator Fire pump not required for this building.
Specifically excluded in MOU and not provided in
the Fire Command Room based on this
clarification.
Schematic building plans indicating typical floor Provided per MOU.
plan and detailing the building core,means of
egress,fire protection systems,fire-fighting
e ui ment and fire de artment access.
Worktable Provided per MOU.
Generator supervision devices,manual start and Specifically excluded in MOU and not provided in
transfer features. the Fire Command Room based on this
clarification.
Public address system where specifically required Provided per MOU-Fire Alarm System has Voice
by this code. Alarm/Paging Capability and is controlled from the
Fire Command Room for Building A,C and D.
Building E(Chalets)has a separate system for
those buildings and is controlled from the Building
E Fire Command Room.
Based on this Request for Clarification,BCER is requesting that the Fire Command Room in Building C
and E be provided with the equipment listed above per the May 15, 2006 Memorandum of
Understanding. For clarification BCER is also requesting that an Elevator Status/Annunciation Panel in
the Building C Fire Command Room be provided for Elevators C1 and CS only.In Building E an
Elevator Status/Annunciation Panel for each of the elevators in Chalets will also be provided. No other
equipment as listed above from Section 911 of the IBC is being proposed for inclusion in either of the
Fire Command Rooms.
Due to the cunent project schedule for completion and anticipated occupancy later this month(or early
December 2007)we would request your concurrence of this clarification by signature of the document
below.We are anticipating that the components listed above will in place and operational for the issuance
of at least a Temporary Certificate of Occupancy for Building C. However, due to the time needed to
design,produce and install the elevator status/annunciation panel in the Building C Fire Command Room,
C:�DOCUMENTS AND SETTINGS\SCR�DESKTOP�BCER VFD FII2E COMMAND ROOM CLARIFICATION 11.19.07.DOC
5420 WARD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•FAx: 303-422-7900
there may be a request for a mutually agreed upon time frame for the installation of the panel.Please call
if you have any questions regarding this request and contents of the document.
Prepared by:
BCER Engineering, Inc.
Stephen Rondinelli,AIA
Principal,Director of Fire Protection and Life Safety
�/
.�1PP VE
;
� � �
�_. c'� 6�� �CU CJ�'� _.;�-i�_.��-�`��f i'`"—�� // ��� ` �
TOV BUIILt7ING I�EPARTMENT/DATE TOV FIRE DEPARTMENT/DATE
C:�DOCUMENTS A1QD SETTINGS\SCR�DESKTOP�BCER VFD FIRE COMMAND ROOM CLARIFICATION 1].19.07.DOC
5420 W?,RD ROAD,SUITE 200,ARVADA,COLORADO 80002-1838�TELEPHONE: 303-422-7400•F/+x: 303-422-7900
� �
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT Permit #: A07-0099 � bCo�v U 1,�
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED �Jd� � Ul CD�`
Location.....: VAILS FRONT DOOR-ONE VAIL PLACE Applied . . : 09/14/2007
Parcel No...: 210108278002 Issued . . . 11/08/2007
Project No : t -� ��, vc �� Expires . .: OS/06/2008
OWNER LODGE PROPERTIES INC 09/14/2007
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 09/14/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-S
CONTRACTOR ENCORE ELECTRIC 09/14/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-5
Desciption: ONE VAIL PLACE-WIRE AND PIPE ONLY
Valuation: $4,500.00
*+a+«*�****+******s+**�x*****x�***r**r*�**r*�******s*+*rs*******►*s* FEE S UMMARY ****r�**tr**�******+*+*�****+***r*r+*�**********�*s****+****
Electrical---------> $o.0 o Total Calculated Fees--> $4 0 0.�5
DRB Fee---------> $0.o o Additional Fees----------> $o.o 0
Investigation----> $o.oo Total Permit Fee--------> $400.�5
W ill Call---------> $o.o o Payments------------------> $4 0 0.�5
TOTAL FEES--> $4 0 0.�s BALANCE DUE--------> $o.o 0
�*****►*****�r******��*�:�**�*+�:x*r**s***s***v****�***********aa�***��*s**�******�*******►*��*vs**+r***►******�*�**+a�*****+s�***t*****r********►*«
Approvals:
Item: 05600 FIRE DEPARTMENT
10/11/2007 mcgee • Action: AP The wire pull permits are approved subject
changes on the alarm plans from BCER.
*�..*.,*���.*.���*.*»*.*.*.*.*...*.***..***.*..*,:**.�***«**.*.*�«+:..�*+*+**,�»**.*�.******,.***.,�.�+,:�,*,:*��.**�.*+.,.*..*.*....*.**....,�**.*�*
CONDITIONS OF APPROVAL
*�*��*****.�*.*..*******..****�*,*.*.*.*�..*.*.*.*�***..*..,*�*�*�«*.*.*.***..����*.*.***«**.****«...******.*.*.*.��«�.�,:»**�**.�.«*...��*.***...
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and ot ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHA DE TWENTY-FOUR S IN ANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM.
tO
�
. ,
*******************�************************************************+***********************
TOWN OF VAIL, COLORADO Statement
***********************+***********�******************+***********�*************************
Statement Number: R070002475 Amount: $400.75 11/08/200701:44 PM
Payment Method: Check Init: LT
Notation: Encore
Electric, Inc. / ck 1829
-----------------------------------------------------------------------------
Permit No: A07-0099 Type: ALARM PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-ONE VAIL PLACE
Total Fees: $400.75
This Payment: $400.75 Total ALL Pmts: $400.75
Balance: $0. 00
**�*****************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 168.75
PF 00100003112300 PLAN CHECK FEES 232 .00
-----------------------------------------------------------------------------
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT Permit #: E07-0289
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VISTA BAHN LIFT HOUSE-OPERATOR SHELTER Applied . . : 10/24/2007
Parcel No...: 210108278002 Issued . . : 10/30/2007
Legal Description: ��t S�� -Ud�� Expires . .: 04/27/2008
Project No :
OWNER LODGE PROPERTIES INC 10/24/2007
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 10/24/2007 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
CONTRACTOR ENCORE ELECTRIC 10/24/2007 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
Desciption: INSTALL A 150 AMP ELECTRICAL SERVICE TO MANUFACTURED
BUILDING. CONNECT FACTORY INSTALLED INTERNAL WIRING TO NEW
SERVICE
Valuation: $8,400.00 Square feet: 0
r*�***********►x***»ss*********+***��*�:a�+********+******+**r:+s**** FEE S UMMARY *rr**�r*+**********►*�xx*************+�*�*****r*s*�►**�+*�**
Electrical---------> $196.65 Total Calculated Fees--> $200.65
Investigation----> $0.0 0 Additional Fees----------> $o.0 0
W ill Call---------> $a.o o Total Permit Fee--------> $2 0 0.6 5
TOTAL FEES--> $2 0 0.6 5 Payments------------------> $2 0 0.6 5
BALANCE DUE--------> $o.0 0
•*�.�s*+�+�*s**�*e*****r.**:s.s:+.**r►*�t*t*********::*sr*rr►►*►*as�********►*►*»**:r***s**+x**t�xtx****:s***+*ss.***:**xs►*►t*t.�*+*****s****+***
Approvals:
Item: 06000 ELECTRICAL DEPARTMENT
10/26/2007 SHAHN Action: AP
Item: 05600 FIRE DEPARTMENT
***.*.*.+****..+*+r*.*.*++*........:,:*.+*.�*�**.***.,*��*.�*.+�.,*,.*.*+«+.+**.�**+.****�*....**�*.*«.*►*s*.�+.+..�.....:.�..*«*.:.*...*.��.�*+.+
CONDITIONS OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
�***.�.+*.******�.�**ss+.*�*.*****�.*.+*++.M�***���.*s*:.*,:**«*s*�..�.*.*.*.*.»***.�*�*�.«�**.++�*s�+**�**.*+*****,:.*«.�+.+.++.+*..►.+*.+.�.*+*.»
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE B PHONE A 479-214 UR O ICE FRO 8:00 AM-4 PM.
SIG F O, ER OR OR ITIMSELF AND OWNER
***+*********************************+*********�**************************+*****************
TOWN OF VAIL, COLORADO Statement
*******************************************************�************************************
Statement Number: R070002370 Amount: $200.65 10/30/200709:10 AM
Payment Method: Check Init: DDG
Notation: Encore Electric
1819
-----------------------------------------------------------------------------
Permit No: E07-0289 Type: ELECTRICAL PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VISTA BAHN LIFT HOUSE-OPERATOR SHELTER
Total Fees: $200.65
This Payment: $200.65 Total ALL Pmts: $200.65
Balance: $0.00
**********************+****************************************+****************************
ACCOLJNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 196.65
WC 00100003112800 WILL CALL INSPECTION FEE 4 .00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UN�I�1��` ��vZ a
Project#: ���d
Building Permit#: Qaz —o t ey
. �• � «► �� Electrical Permit#:
���jj� � 970-479-2149(inspections)
�r
75 S.Frontage Rd.
Vail,Colorado 81657
TOWN OF VAIL ELECTRICAL PERMIT APPLICATION
CONTRACTOR INPORMATION
Electrical Contractor: Town of Vail Reg. No.: Contact Person and Phone#'s:
�-Catt.ti �.i-E�-t�'i-�- ��. ,�3 � —F� T`��-R�r� (_�Ntalcit- �t'l l- l�l�3
E-Mai)Address: ��,�a,,�w�r�,.��,,�f, ��,,,`„ Fax#: c�cec� _ � �
Contractor i ature:
b
COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK(Labor&Materials)
AMOUNT OF SQ FT IN STRUCTURE: ELECTRICAL VALUATION: $ $ c�oo �
Contact Ea /e Coun Assessors�ce at 970 328-8640 or visft www.ea /e-coun .com for Parce/#
Parcei #
6P�a-R-tcf�. SHt.�Tt�rs. IT`{ GaRC CRLC.tic Pctr.vr.
Job Name: Job Address:
Uz,STA 43!ti-c�-1� (�<T t1-w��.- ��..L�. �o
Legal Description Lot: Block: Fiiing: Subdivision:
Owners Name: V�� �i�� Address: Phone: ��9 _ 3�T8
Engineer: Address: Phone:
Detailed description of work: �� w �3 0 � � �� ,ro�t 3� e�.c���.�. sww��
'!e V+e►vw�-�urc� lnvcic!-�� . C`qhv�Ei-T Fh'��1' 3.t�irae-�-tc.�0 �rR.�►.�/►+-- c.+Z1�LKlo 10
K R.w+ l�o A r�P U�t'Mt-c.+��- ��-�.
Work Class: New�, Addition ( ) Remodel( ) Repair( ) Temp Power( ) Other( )
Work Type: Interior( ) Exterior(� Both( ) Does an EHU exist at this location: Yes( ) No( )
Type of Bldg.: Single-family( ) Duplex( ) Multi-family( ) Commercial� Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: � No. of Accommodation Units in this building: �
Is this rmit for a hot : Yes No
Does a Fire Alarm Exist: es O No(J(� a Fire Sprinkler System Exi •
. p __ _
. >
******************* **** *********FOR OFPICE USE ONLY**,�***** ***���`,�*;�� *** *
other F�es: Date Reoeh►ed. pF VAIL
DRB Fees: A ' .' B :
Planner S n-off:
F:\cdev\FORMS\Permits\Building\elecacal�ermit_11-23-2005.DOC Page 1 of 2 11/23/2005
.
- t
�awxo�v� �
Amendment to the 2002 N.E.C. Town of Vail Ordinance 4. Series of 2005
a� Overhead services are not allowed in the Town of Vail.
� Underground services sha//be in conduit (PVC) from the utJ/ity transformer to the electric meter, main
disconnect switch, and to the first electrical distribution circuit breaker panel.
� The main disconnect switch shall be readi/yaccessfb/e,andlocated next to the meter on the exterior wall of
the structure. All underground conduits are required to be inspected before back-filling the trench.
ra' In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common
walis and spaces are exempt.
�e' NM Cable (Romex) can be used on/y/n sfng/e and mu/ti-faml/y dwe//ings not exceeding 3 stor�es
Type NM cannot be used in any buf/ding mfxed with Type�yB,E,F,H,I,M&S ocrupancfes
�' A/uminum conductors smaller than size #8 are not permitted.
TOWN OF VAIL ELECTRICAL PERMIT GUIDELINES
o All installations of exterior hot tubs or spa's require a DRB approvai from planning. This application will
not be accepted without a copy of the DRB approvai form attached (if appiicable).
o If this permit is for installation of an exterior hot tub or spa on a new elevated platForm or deck over
30"above grade, you must also obtain a building permit.
❑ If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platForm,
a structural engineer must review the existing condition and verify that it will support the added
concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing
with this appiication.
❑ If this is a remodel in a multi-family building with a homeowners association, a letter of permission
from the association is required.
❑ If this permit is for a commercial space, two (2) sets of stamped drawings are required. E/e�ct�ca/
one/ine and pane/schedu/es a�e required if/oad is added or distribution is a/te�al,
I have read and underst th bove.
�� o
u � O
Signatu D te Si ned
If you have any questions regarding the above information or have additional questions,
please contact the Town of Vail Electrical Inspector at 970-479-2147. The inspector can be
reached on Monday thru Friday mornings between the hours of 8am and 9am. You may also
leave a voice mail and the inspector will call you back.
F:\cdev\FORMS\Permits\Building\electical�ermit 11-23-2005.DOC Page 2 of 2 11/23/2005
j�o�•� Cn.oss Tn.4,�s��►�
5oc �.�A �� r+a o�r�TZZ�
za811za� 3� y���
rr�+-*r�.�--
� 'rG�i GOK �u�'Q
3 r�►�,►�,,,� �
S T�K,��.� �'"�
7 L�H-rs
►�J, sT�.- 3,��� =
L�� t��u�
�ct+�p u c..tL_
3o A Z� Lu--rE►�w�� (�r.P*Z
4
�e
(0 1.._,-��'I�.w S�. �
g L'��� I..�►s� �
1� L',�fw�,st �
;.
Z Z5 a- rJ�vtA 3Z
�� � � ��
�z�f��
j?MN1f,C.QOhQD
G Ro
.c c1'r`�
ReP
�yn � - =
clatl c�� u '�'iL �o—�8 ---3 =r I
��I C��1�'1t�FV�1
$VZf c�Zi
—�� M �, ��
�� �w�r �'�z�
n� 7� �
� �
� ��"r"�-{�!1 a) � �l'"H .��") Lv
� �z^�, ���-� a s���-� z
U„ '7SM��J,� ! O"�� ?Vi?yf'1V3,� S
T7�'
' h J�+d �as sriy1 �
d�t� ��mt11�7 �Z d°E �,,,,,J ,+oQ s�v�1
�
-��n��tl�S --�'�.!`�+dd
�� � '
a�Sno� !��1
r��►c� -v1S 'I'�
1Z no�+c� �lld u h — I
- _ d►'r°�_--,''1i� ri,t-H�.: c� _ }9
� i
a� s
8 L
� s �
�. £
--- � ,.
��+�v� �OS I 'd�
�: _ h—" �,nJS
� �rd ,,h
., .,, �
�� ��
�+�+� ���t1 �
��d �� ��z - )
-�! ��►�x �, - h
. ��d5"�
��a,J� C �s �
� � `�
�
'''"`'�"h �� � '`Qzl�Soz
aa�.��ao�wr� �� d�.��oc
��� Ssov� 1���H
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT Permit #: A07-0108
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 10/04/2007
Parcel No...: 210108278002 Issued . . : 10/18/2007
Project No : �'�—�j �. pp 2� Expires . .: 04/15/2008
OWNER LODGE PROPERTIES INC 10/04/2007
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 10/04/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-5
CONTRACTOR ENCORE ELECTRIC 10/04/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-5
Desciption: VAILS FRONT DOOR BLDG'A'NEW FIRE ALARM SYSTEM
Valuation: $48,536.00
*****►+**�*�+*****�*+s*******+**�**a�*********x***+*�+*�*+******�*** FEE SUMMARY rrv*+*�rs*t*�***�*tr***r****r+**+******s�****►*x**�*►+*****�
Electrical---------> $o.o o Total Calculated Fees--> $z,0 52.10
DRB Fee---------> $o.o o Additional Fees----------> $o.o 0
Investigation----> $0.0 0 Total Permit Fee--------> $2,0 5 2.10
W ill Cal I---------> $0.o o Payments------------------> $2,0 5 z.10
TOTAL FEES--> $z,0 5 z.1 o BALANCE DUE--------> $o.o 0
*s+«»�::e+«*r***»rrr:r*e*r�s**r��*ss**r*****r**:****r***s****r*+rr*r***s�*****s*s********s******s*►*►*+*x�+**+*e►+*�*�a�:**��*»�**r�v*�**�►**r****«**
Approvals:
Item: 05600 FIRE DEPARTMENT
10/17/2007 McGee Action: AP Single station manual pull stations are noi
approved.
Sheet FA3 .33 does not show any devices .
Corrections are required before rough-in inspection.
Re-submit change in specitication to retlect double action manual pull station pe:
adopted codes and standards .
Re-submit Sheet FA3 .33 with devices.
10/18/2007 mcgee Action: AP FA3 .33 issue resolveci. Floor plan only. No
this area.
Pull station re-submittal is approved with double action device.
.�.».*....+.�..*..*.*.*.:�.**.»..*.*.*..�*.*.*.�**..*:*..:..**«....*...*..�.,.*:...*�.*.:.�**..**...,�..�.***.*.*+.*...+...+..**.«:.�..�...*«**..
CONDITIONS OF APPROVAL
..*.�.,�.�.�..........�*�.�...*.*..,.*.�.�.�.****.**�****«*��**.*..*.*****...*...*...***.*.*.*.*..**.�..*.�.*....**,.*,*»...*......*.**..�.*.**...
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of t Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HO IN AD BY ELEPHONE AT -2135 FROM 8:00 AM-5 PM.
U O ER OR ONT CTOR FOR LF AND OWNER
*************************************************�*********+********************************
TOWN OF VAIL, COLORADO Statement
**********************************************************************�**********+**+******+
Statement Number: R070002262 Amount: $2, 052 .10 10/18/200703 :35 PM
Payment Method: Check Init: DDG
Notation: Encore electric
1812
-----------------------------------------------------------------------------
Permit No: A07-0108 Type: ALARM PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A�
Total Fees: $2, 052 .10
This Payment: $2, 052 .10 Total ALL Pmts: $2, 052 .10
Balance: $0. 00
**************�**************************++*************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 1, 820.10
PF 00100003112300 PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
TOWN OF VAI'FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT Permit #: A07-0118
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 10/10/2007
Parcel No...: 210108278002 Issued . . . 10/18/2007
Project No : Expires . .: 04/15/2008
�'Z3 O� �C�o=� �
OWNER LODGE PROPERTIES INC 10/10/2007
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 10/10/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-S
CONTRACTOR ENCORE ELECTRIC 10/10/2007 Phone: 970-949-9277
ATTN: SHANNON GEIER
2107 W. COLLEGE AVENUE
ENGLEWOOD
COLORADO 80110
License: 668-5
Desciption: ONE VAIL PLACE LOWER LEVEL FIRE ALARM SYSTEM
Valuation: $5,000.00
****+�+��t**�*►�*»********+*r*r*�*+rs+***►r***+***��**�s***�*►rt**** FEE SUMMARY +*v*******r�s********+*+****r***t****r****+*+****+**+�*w*t*►
Electrical---------> $o.o o Total Calculated Fees--> $419.5 0
DRB Fee---------> $o.o o Additional Fees----------> $o.o 0
Investigation----> $0.00 Total Permit Fee--------> $419.50
Will Call---------> $o.oo Payments------------------> $419.so
TOTAL FEES--> $419.s o BALANCE DUE--------> $o.o 0
•*a*r***s****►**�+a+**s**r****s+******�**********►**a��+x+*****r��*s*********�***»**s**+**»r*�**s***********�*+**�******���+«�s*�**�**+**********
Approvals:
Item: 05600 FIRE DEPARTMENT
10/18/2007 McGee Action: AP Add detection to restrooms (typ) per TOV ac
and standards.
....*.*.*....*..**..�.***......�:*,*,*.�,:,*.*.*.*.*�:..*.*.*...**..*.�.�.*,��,....*�,:.....**.**,*..*..*.�*.�.�.�*.�.�*�,:,*.».**...*.**...�....,.*.
CONDITIONS OF APPROVAL
�*.,�*.*,*.��**���«*��***�**.*.�.*.*.....�*,*,*�*�*�**«*.*«*.*..*��..�...*.*.�*..**�**.*.�**..�*��.**��.,....**..**..**....***.*.�*�*.*.*.�*�....
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPE ON SHALL B MADE TWENT R HOURS IN ADVANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM.
� � �
� �
********+*+++***************************************+***************************************
TOWN OF VAIL, COLORADO Statement
*********************************************�*************************�********************
Statement Number: R070002261 Amount: $419.50 10/18/200703 :34 PM
Payment Method: Check Init: DDG
Notation: Encore electric
1813
-----------------------------------------------------------------------------
Permit No: A07-0118 Type: ALARM PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $419.50
This Payment: $419.50 Total ALL Pmts: $419.50
Balance: $0.00
****************************************************************************************+***
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 187.50
PF 00100003112300 PLAN CHECK FEES 232. 00
-----------------------------------------------------------------------------
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
SPRINKLER PERMIT Permit #: F07-0072
�3,��-a��g�� -��-�t��I
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITEBUILDING'A' Applied . . : 08/02/2007
Parcel No...: 210108278002 Issued . . . 08/07/2007
Project No : Expires . .:
���.�d� -O���
OWNER LODGE.PROPERTIES INC 08/02/2007
PO BOX 7 �
VAIL
CO 81658
CONTRACTOR FIRE PROTECTION INC 08/02/2007 Phone: 303-399-1366
4981 EAST 39TH STREET
DENVER
CO 80207
License: 176-5
APPLICANT HYDER CONSTRUCTION, INC 08/02/2007 Phone: 303-825-1313
543 SANTA FE DRIVE
DENVER
CO 80204
License: 109-A
Desciption: CONSTRUCTION OF A 3 STORY LINDERGROLJND PARKING STRUCTURE
WITH LOADING DOCK AND ACCESS TUNNEL CAST-IN-PLACE. ALL SITE
WORK IMPROVEMNETS AND LANDSCAPING-New fire sprinkler
system and standpipe installation for entire Building A
Valuation: $294,225.00
*r*s*****+***********tstr***t**�s**t*►*s****►��*►*t***s****�*��t**r* FEE S UMMARY x*****�*+*a**��+*+�*+******�+�**�:*+�*+*�*s****��e***+*��***++
Mechanical---> $o.o o Restuarant Plan Review--> $o.0 0 Total Calculated Fees---> $12,8 54.56
Plan Check---> $3 5 0.o o DRB Fee---------------------> $0.0 o Additional Fees-----------> $o.o 0
Investigation-> $o.00 TOTALFEES--------------> $1z,854.56 TotalPermitFee----------> $12,854.56
Will Call-----> $0.0 0 Payments-------------------> $1 2,8 5 4.5 6
BALANCE DUE---------> $o.o 0
**►*�*►*��*»xt******►*���*****►***r+*��r*+�**��r*s�r*+****t*+***tr*�********++t**r**************�***�***r********�x*********�*****�+:*r*******r*�
Item: 05100 BUILDING DEPARTMENT
Item: 05600 FIRE DEPARTMENT
08/03/2007 mcgee Action: AP Remote Area A05A
l . The Hydraulic Design Intormation Sheet inciicates the area is 1950 sqtC. The hyc
on Sheet 2 of 8 indicates the area is 2089 .
2 . The Hydraulic Data Summary shows 21 heads calculated but the Flow Summary list;
heads.
3 . Node 135 is not on the plans.
Area A05
4 . Hydraulic Design Sheet shows 1950 sq ft and hydraulic data shows 2032 sq ft .
5 . Caution: Velocities in 2 1/2 in pipe in proximity ot Node 198 to 97 may present
challenge in that the pipe has two 90 degree ott sets shown. It appears the pipe �
wrap beneath a beam (not clearly shown) . Pressure stress on tlex tittings may reqi
bracing.
Conter with installer ret additional issues on mechanical tee 's and tittings trom
manufacturers .
Upper Level Water Curtain
6 . Provide rational for density at water curtain (3 gpm/1 ft or . 15/130sqft/hd. ) .
7 . Is design area 2047 sqft or 1950? Both are shown.
Zone A06
8 . Two Hydraulic data plates are shown, both labeled "Upper Level Water Curtain" .
more accurately reflect area of coverage.
9. Resolve conflict in design area (2028 vs 1950) .
Sheet 3 of 6
10 . Provide tamper switches .
11. Provide filter and dryer for air compressors .
12 . Provide wiring schematic and show source of AC for compressors .
13 . . Lable each DPV to reflect area ot coverage. Provide graphic color plan and mc
with high end pressure, low air pressure, and trip pressure on each zone.
14 . Protect all drum drips from vehicular damage.
CONDITION OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
.*..*...+..*******...:.�..+**:..*:+.*:.*.+�.�..:***.�..*.*�*.:�*:*..�.*.*..+,*:***+*�**.*....:***+**.***�**.*�***.*��►«*++.��+*•*.++..+.++.*.*�..
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan,
and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all
Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review
approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN AD ANCE BY TELEPHONE AT 479-2135
FROM 8:00 AM-5 PM. J-'��, J
* j�� '�----
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER
************+*****+***+********+++++***************+**************************************�*
TOWN OF VAIL, COLORADO Statement
********+**************�*********************************************�**********************
Statement Number: R070001452 Amount: $12,854 .5608/07/200710:29 AM
Payment Method: Check Init: DDG
Notation: Fire Protection
32490
-----------------------------------------------------------------------------
Permit No: F07-0072 Type: SPRINKLER PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $12, 854.56
This Payment: $12, 854.56 Total ALL Pmts: $12, 854.56
Balance: $0. 00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 SPRINKLER PERMIT FEES 12, 504.56
PF 00100003112300 PLAN CHECK FEES 350.00
-----------------------------------------------------------------------------
�ug i � 2007 8 �44A�� F1RE ?ROTECTIGN , INC 3033215D8� No � 2161 P � ? �
�o�- o��.�
APPtICA'TION WILL NOT BE ACCEPTED IF iNCOMPLETE OR UNSIGN D..
,--�-� S4 Project iF: �'.'�� � �,
----� `�8uilding Perrr�lt#: �" _�� :���=„ �"
•K �""' Sprinkler Permit#:
� � 970-478-2135 Inspections)
(
`�"; TOWN F VAIL FIRE SPRINKLER PERMIT APPLICATION
������ Fire Sprinkter shop drawings are required at tlme of perr»it submittal and
75 S. Frontage Rd. must include the following.Permit appllcation wi11 not be accepted
V'all� Colorado 81657 without thls Information:
• A Colorado Registered Enginee�s stamp or N.I.C.E.T. Level 111(min)stamp.
• Equlpment cut sheets ot materials.
• Hydraulic caiculations.
. A:State of Colorado Pian Registratlon form.
• Plans must be submitted by a Registered �'Ire Protection Contractor.
CON',I',RA,CTOR 1NFOR1►�,A,TION
F,I�Sprinkler Contractor. Town of Vail Reg.No.: Contact and Phone#'s:
�t � �::c�aa ��1�: 1��. I�to - S 3e� ��i� i.��.�� t��N �5
E-Mail Address:
Contractor Signature: �
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor�Materials)
• Fire Sprink�er.$ �r�"�Z,�Cj a^
� �
Coniact Ea le Coun Assessors Office at 9T0-328-8640 ar visit www.ea le-co .com for Parcel#
A�arcel# ' '�°
`� ������"� '���� .»��
JoB Name: �` '^ Job Address�
+ uy f1'°��7 Gck� �'� �4 174` � - �u�.�' Ci'�z�' �ia. �i�(.
Legal Description L . B c:k: iling: : �
O1M1Brs Ne�T1e:�� w�i Addr�ss: +�� �, �,,,,; �r��_ e• •�
0
Englneer: Address: ' � - ���
Detailed Loc:atlon ot woric:(i.e�.,floor,unit ft,bldg.�) � �y. /� .
�'rAf�(,'S ccrZ �n�„', �'°0���''v � ''N�� ' ✓1,S S�
Qetailed description of work� '
�'w �,.�,�kl;� 1�0 �?�dF'tF'r �NaT.rti�7�.�.s ����: � 3 ��
Work Clr�ss: New�Addltlon O Remodel( j Repair O Retro-t{t O Other O
Type oi 81dg.: Si�gle-family( ) Twafamity( ) Multl-family( ) CommercfaJ,�}-..Restaurant( ) 4ther( )
No.of Existing Owelling Units in this building: No.of Accommodation Units In this building�
Does e Flre A�arrn Exist: Yes( ) No( j Does a Fire Spiinkler System Exist: Yes( ) No( )
w,�*w«:*:x.��►+r�,��.�.w�.�t,.*�,.��*,�*lx*�xx.A..FOR OFFICE USE ONLY*,��*#..«�►,�,►w,�*#�#***�*,�,.,.ww*«#*x**��.�
� -- I. g
� tit�
;a i;>'!
ifl i; � . . ._ -
5t .
���j __ , �/a- �s� �-�
„Y!1{�8181C�`������ , 0�/2,l20�2
JUL/16/2007/MQN 08: 04 AM N�CCOG FAX No, 9704681208 P, 003/004
���_ �Q`� ��� ��`� . , . . �
Gw�.t�; �o�G �. �Q�P. �.tC.� � � � � .
a��
� � � . NQr�hwest Colorat�v�Councti�a�Governmer�ts T� .
���raroR���zr ap��,arcarror� ��,
Pennit�. ���_1 d� , 3esrisdiction�•�e-+�x L�,� ��-,2 Fax#
� Tota! Fee-�� Da�e Patd -!!-� E�ea p�# �����l �°t��
, ptan Revle�wed and Approved by ate Issued "7-l��'7
l�is sedlon bo be compta#ed by NWCCO�"a Pernt�t Facpirdtiotl Date �-/n'��b'�
� ** Ail the�o[Iowiing must be aampteted by Che�tevatar cont�ac�or**�
• Tn�awrat�,itEeglbte or mfssing information wiil c:�use�delay In ttte applicatlon proce�s.
� Please complet� � separa�e applica�ion per c�ttveyanc�. ,
Jurisdi�fiion �uilding P��mit#� �)�_,��' �� �
.7ob Address � � � � ' tl� � �. '� C� ��la ��
. �. Bullding ar Homer�wriet's.Nam� �1 � �.-�S �'�'Drti� �C°aca f� �J� � r�' �
� . own�r V fl i#, R�sc�c�.�-s �J�.v e,1 o p�rt� t�n�.p a.r�� .
. , M�iliJ'1g Addriess. ��� �f�r�C�h r�1.a�rz-K �.0 cz�. �1 V O n ; C,i� $!,r�,.2.,p .
.Pno���!7 o f S t-f-� � a�.�35 �_ . �#°l�10 �L#- 5 �:���
Elevator Cot�r�or t r i S�a 2.1�1}�,� '���11 A�"C� t�.
INctltillg Add�ess �(� � �7� �-�-�C� �7 �,�,�� , �C:� � �" � �)
, Phone# ��0 ' �J c�l�� ��� Fdx# ��a" �,.s�•� ' �Q �� _ �
• * Permit�e `re 1�ane ear f�r n�wr i tatior�s ar+d s�x�rotr€hs for a[tera�lons*
� New in�tallatfon� Unit or Canfiract# '��� �'a.0
��Albaratlan [unit cannat be retarped t»servJc�wdtilinspee�e�and�ppt�ov�:d byNINCC[)GJ
� nas�rit�e wa,rk_ W i��0��, �t�G�,rCt.u..L.i�... ��C�(�'� � �C'.t.r,G�.2'�.�_ .
Ho'nt� � n�rn►�rvsraws►Yror� �EES � .
' ,I hereby aertlfy t1�at I lwv+2 nead 8nd examined this aPPI[cat9a► passenger aC fr�ight devator,[u�la,�talOr:l�o1►�ng wattc
� '. arid know tfie satne hf f�e trve and aorret#. A![P�ns of ' Up to a�d hdudu'i9#50,000 of valtration=�350.00
, taws and ordtrwr�tes ganreming�this type af worlc will be Over�50,000 aE vatuatlan=�350.00 plus�6.00 f�ead�
• . oamp�ed with whect�e�s�Fed perein or not Tt�e qranti�g flF #i,ovo.00 rn frattion�reoF ov�er;5o,000.oa
a permit doeS hot p�+esume to give auU-�ohLy Co rlv�ate ar C�noe! ' �
t#�e pravisions of dnY otf�t'Stabe or bd{aw regulatln9 ue+�,awnt�wat�or�vate e�esiiteace e�ovabo�: .
on or the pe�ormanae af�vc.t;on. Up to arid iadudiog$20,000 oF va[uatqan=$7�0.00
Uver�20.000 of valual�on=$250.00 plus$3.00 for eacri '
' �; c� �b"7 . �t,000.00 or fr�tian�ov�ec�zo.000.ao .
. 51g c+�of tontractor or autlraized agent Date
� Fees fpC ciu�jor al6erat9qri5 Shall be ds set fath�t Tabte 3 A aF the - .
- - --- - UniEOtm Administ�-ati�e Cbde or Tabte i-A.
Slgnatur+e of owner C►ate � �� t �1 � � w
YALU�ITxON=.__.
. ��-e. - -�' 3 5� .0� �
Etevatar pian review and field inspec�ons wl[I be c�nduc�d by d�e Northwest Colorado Cour,dl
. be forwarded to NWG'pOG for�ew and app�nvat. Schedute insp�cqons by con�Gting the MN t
970-R58-0295 ext 108. Pl�ase make d�dcs yabEe ta NWCCOG. �
����
;'r ��
11-02-2007 Inspection Request Reporting Page�'f6
4:23 pm Vail,CO - Citv �f
Requested Inspect Date: Monday, November 05,2007
Inspection Area: CD
Site Address: 174 GORE CREEK DR VAIL
VISTA BAHN OPERATOR SHELTER
A/P/D Information
Activity: B07-0164 Type: COMBLD Sub Type: NCOM Status: ISSUED
Const Type: Occu�pancy: Use: V B Insp Area: CD
Owner: LODGE PROPERTIES INC
Contractor: DOPPELMAYR CTEC INC. Phone: (801)973-7977
Description: CONSTRUCTION OF A NEW OPERATOR HOUSE FOR VISTA BAHN
Requested Inspection(s)
Item: 537 PLAN-FINAL C/O Requested Time: 08:00 AM
Requestor: DOPPELMAYR CTEC INC. Phone: (801)973-7977
Comments: w/c cody�470-9139
Assigned To: BGIBSON Entered By: JMONDRAGON K
Action: ...-------.� Time Exp:
`�.
� Iter�` 9Q'fBLDG-Final �` Requested Time: 02:00 PM
Requestdr: ,DOPPELMAYR CTEC�NC. Phone: (801)973-7977
Commerits,�w/c cody 470-9139
Assigned To;, GDENCKLA / Entered By: JMONDRAGON K
Actrpn: f' Time Exp: ��'�~
�,f ��
�'�...
w.
� �.�
�_ ..__- "�:,.�
�, ,:�
1 �� T 4
A'}.:�
� �n���'.. �., _ �t'�
-,,l i
,F�,� � ,$
I�"; , �
r/� f
�
e- J... � � aa f
\ �`1` �,' j ,
.
.� � 4
�
—_.
�1� ��� ._=�i � �,�`�1
\,f� ��, r� �
i .
E
i
Inspection Historv
',
Item: 10 BLDGFootings/Steel + UFER qrd **Approved"`" `.�
06/28/07 Inspector: JR�71 Action: AP APPROVED
Comment: FODTER AND FOUNDATION PAD APPROVED
Item: 20 BLDG-Foundation/Steel
Item: 21 PLAN-ILC Foundation Plan
Item: 30 BLDG-Framing
Item: 22 PLAN-ILC FRRMING
Item: 50 BLDG-Insulation
Item: 60 BLDG-Sheetrock Nail
Item: 70 BLDG-Misc.
Item: 90 BLDG-Final
Item: 531 FIRE-TEMP. C/O
Item: 532 PW-TEMP.C/O
Item: 533 PLAN-TEMP. C/O
Item: 530 BLDG-Temp. C/O
Item: 535 DIA-30 DRY REMINDER
Item: 536 DIA-SITE/LANDSCAPING
Item: 538 FIRE-FINAL C/O
Item: 539 PW-FINAL C/O
Item: 537 PLAN-FINAL C/O
Item: 540 BLDG-Final C/O
REPT131 Run Id: 7199
. . � W ��_���
: , ��
��.���
� ��- } �„ _ �..3-o� -oo zg
� � F� y _.�. . ,;.
. �.�
c tr�.!.�; I�i:llc l 1��;� IN( . ���� �
� �PY
.a����i �o. Zc,o� � C� L� p M Uw..�s �r�.�-
�
� �
�o�
N�r. Leonard Sandoval Ap� 2 4 �001
"I�o�i-�i ol�Vail Uepartment ol�1'ublic Wc�i 's l,.O ��i`� A
i.i09 Lli:llorn Grive w�` Q�'�/�f U
Vail. C:O 81057 §.,, �,,c �� ��
� �
1tL: Construction Site AcccSS .ind Staging Ylan— Vail's Fi•ont lloor
Amended for 2U07 Construction Scason
Dear Leonard.
t�c�llo���ing is a summary c�l�the site sia�ing and acc;Gss plan iar the ceferenced E'roject:
l. Schedule
A. 'The construclion sch�dulc is based on 1�londa}� through F'riday 7:OOAM tu
�:30 PM and Saturdays 7:00 AM to �:30 PM. Actual work haurs may vary
lnrt t�ill conf�rm to "I'own of Vail requirements.
B. The 2007 Vail Village/ Lionshead Village Construction Hours InPormaiion
Handout for holiday hours is incorporated into the Project Schedule.
C. Hyder Construction will provide �veekly schedule u}�dates to the Town of
' Vail.
D. I-lyder Ccanstruciion will continue io attend the ���eekly "I'OV coordination
meetings ta update the progress of the projeci and its impacts upon acijacent
�ropertics.
T. f1 plan for the occupancy orthe various buildii�gs �vill Ue issued at a later date.
II. Attached is the site access and stagi�ib plan for the period of April 23. 2�07
through November 16, 2007:
A. During this per•ioci the site will Ue accessed i'r�m Vail Road �n the ���est
and from thc east via Vail Valley Drive through the Gt�ld Peak area.
1. Reference M}��'#2 for the traffic control plan for Vail Road.
2. Reierence MHT#1 ior the traffic control plan for the Gold Peak
Children's Ce»ter.
3, It is assumed that thc bus stop at the Gold Peak Children's
Center will be relocated to the Gold Peak turn out as it «Tas in the
200G Summer Constructian Season.
�. A ience ��%ill be installed at Gold Peak ta separate �oiistruction
activities fi•om the publie.
� .,_•� „----�- �--- • � • ,_ _ .,�_._ �,_,__ ,_� ,•.: ,
n. v uii i�c;aw�a utrCS i7oi iili�tiu uii tisiii�, iut; v 15ta r3unn sx� nn �init
surroundin� ski yard tor summer activitics.
,, , l, i , . • . . �. . � i.,� �.I„ �� • . . � F , , . . x , , _ � . ... ,
Vail's Front Doar— Site Access and Staging Plan
April 20, 2007
Page 2 of 4
1. Reference the attached Vail Resorts signage plan for pedestrian
access to the mountain.
2. The bike path will be closed between the Bridbe Street Lodge to
Bric�ge Street and Vail Raad. A detour on the bike path will be
set in the vicinity of the Tivoli Lodge. Signage will be posted
along the path directing traffic to the Village. Local pedestria»
trafiic will be allowed between the "I'ivoli ai�d tlie Bridge Street
Lod�e.
3. Mill Creek Road above the project site will be closed to
pedestrian access at the Rockledge Road turn out.
4. A 6' hi�;h fence with �reen scrcen will be installed on the west,
north and east sicies of the project. A 4' high green mesh
construction fence will be installed on the south side of the
�roject on the mountain.
5. The pedestrian streetscape work around One Vail Place, the Hill
Building and Bridge Street Lodge will commence on April 30,
2007.
C. Work occurring afier Noveinber 17, 2007 will be performed under a
separate site access and staging plan. This plan will be submitted to The
1'ow�z of Vail by September 15, 2007.
III. Access to and from the site will be managed from a check point at the delivery
zone on Vail Road.
A. The construction access trailers will remain at the south side of the site in
their current location. Visitors to the construction trailers will be directed
to access from Bridge Street.
B. A delivery check point is established at the west side of the site off of Vail
Road.
IV. An emergency egress plan by BCER Engineering showing e�ress �3atterns trom
affected areas of the South Lodge Tower, the Lodge at Vail and the lower level of
One Vaii Place has been submitted under separate cover.
V. Building specific emergency egress plans for the upper Levels of Oi1e Vail Place
and the Hill Building will be submitted separately.
VI. Homeowners and merchants in the surrounding areas will be pravided with notice
of the construction site access and staging plan once the plan has been approved
bv tlie Town of Vail.
VII. Temporary task lighting within the constructian siie will be provided to meet
OSHA standards and will comply witll The Town of Vail lighting discharge
requirements.
Vlll. 1'wo tower cranes will continue to be utilized on the site. No crane pick will be
allowed over occupied areas or buildings.
A. Aviation beacon lights are mounted at the tops of each tower crane.
I3. `1'hree emer�ency drop zones are shown on the Construction Fire
Department Access Plan b}' BCER Ei1�111�eI'II1�T. These may be utilized in
the event of an emer�ency to evacuate an injured person from within
limits of construction.
Vail's Front Door— Site Access and Staging 1'lan
April 20, 2007
Page 3 of 4
IX. Concrete truck and concrete pump wash aut will be allowed only in designated
areas within the limits of construction. Prior to completion of the project these
• �vash out areas will be remediated.
X. Mill Creek Circle will not be used for construction access at any time.
XI. A detailed SWMI' is posted in the job site trailer.
A. Copies of the SWMP and constructian dewatering discharge l�ermits have
been provided under separate cover.
B. Street sweeping will be provided at both the Vail Road and Vail Valley
Drive access points as required to minimize dust and vehicle tracking.
C. Dust within the site and on the Gold Peak access road will be mitigated
witl� the use of water trucks. Ma�nesium Chloride may be used on the
Gold Peak access road if required.
XII. All construction personnel parking will be managed offsite.
A. During the summer building season the Village parking garage will be
utilized.
XII1. Names and co�itact numbers for Hyder Constniction are listed below
A. Doug Thompson, Project Executive
Office: (303) 825-1313
Direct: (720) 932-3264
Cell: (303) 829-5950
B. Scott Miller, Project Manager(Site, Parking Garage, Chalels)
Uffice: (303) 825-1313
Direct: (720) 932-3271
Cell: (303) 882-6238
C. Richard Snyder, Project Manager(Lod�e ai Vail and Skier Services)
Office: (303) 825-1313
Direct: (720) 932-3279
Cell: (303) $29-2644
D. Chad Craft, Project Manager(Ski Club and Chalets)
Office: (970) 476-2813
Cell: (970) 471-1497
C. Jeff I-Iaselhorsi, Project General Superintendent
Cell: (303) 829-57�1
Site: (970) 476-2811
' F. Bill Partridge, Project Superintendent (Parking Garage and Siie)
Cell: (97Q) 471-5729
Site: (970) 476-2811
G. Rene Robleda, Project Superintendent (Alpine Club)
Cell: (303) 829-1331
Site: (970) 476-2811
H. Steve Barden, Project Superintendent(Lodge at Vail)
Cell: (97Q) 401-0038
Site: (970) 476-281 l
I. Steve Kelley, Project Superintendent(Skier Services)
Cell: (970) 471-5729
Vail's Front Door— Site Access and Siaging Plan
f��ril ?0. 2007
Page� c�f�
Site: (970) 476-2811
,l. Je�hn King. Pr�j�ci Superintendent ("1'llc Cha(els)
Cell: (970) ��5-004�
Site: (970) �76-2811
K. 24 I-lour Emergency Number
(303) 459-5208
��Ve reco�nize thal there �vill be a considerable amount of construction activity ���ithin the
To���n of Vail occurring concurreni wiih the constructian ol�il�e Vai1's i'ront Uoor 1'roject.
We understand that moditications to the above plan may Ue necessary ior the work in the
area ta be completed successfully and on schedule. We will coo��erate in any�vay feasible
recognizing ot course that �ve are alsa under a very tight constniction schedule for the
completion ol�the project.
Sincerely,
HYDLR CONS"1'RUC'rION INC., by
___� ..
;..-,�_ �
�-:=�. ..,_._---�---_._�__-___
�---+�.�---..�:-� _
Scott Miller, I'r�jeci Manager
cc: Mr. Rick Caudel, Vail Resarts Development Co.
Mr. Brian McCartney,Vail Resorts
Mr. Charlic Davis,To�vn of Vail Chief Building Official
Mr. Mike McGee,Town of Vail Fire Marshal
Mr. Matt Royer,Construction lnspection Agency
Attachments:
Site�ccess and Staging Plan Phase 1 —Pebruary ?G,?OU7
MHT#1 and�#2
Vail Resorts Signage Alan
.lob 1-tazard Analysis t'nr Sitc Safety and Cranes
� �
��
C:"���.��T�.'[_.��'TfC.�'� I'��[_`.
JOB HAZARD ANALYSIS FOR SITE SAFETY AND CRANES
JOB TITLE: VAIL'S FRONT DOOR
GENERAL CONTRACTOR: HYDER CONSTRU�TION INC.
JOB LOCATION: VAIL, COLORADO
PROJECT EXECUTIVE: DOUG THOMPSON
SAFETY & TRAINING: NICK FRENZE, MILLER SAFETY
JEFF HASELHORST,BILL
SENIuR S U�E1Z1N 1 ENDENTS: PARTRIDGE,RENE ROBLEDO,
JOHN HING
Date: November 15, 2006
STEP HAZARD NEW PROCEDURE OR PROTECTION
Coordination with Miscommunication Discuss safety policies and procedures with GC.
Contractor
Safety Emergency Work Injury First-Aid/CPR qualified personnel on site.
Res onse
Safety Emergency Work Injury Emergency phone numbers listed in job trailer.
Res onse
Safety Emergency Work Injury Crane equipped with personnel stretcher (stokes basket).
Res onse
Loss Control, Safety measures Hyder's full time Director of Safety&Training will oversee
Inspections neglected or ignored. operations and ensure compliance company policies.
Work in'ury
Loss Control, Safety measures Documented weekly jobsite inspections. Documented
Inspections neglected or ignored. monthly tool inspections. Daily Pre-Task for each crew.
Work injury Weekly behavior audits erformed.
Loss Control, Safety measures Strict discipline program for ALL employees. SEE HYDER
Inspections neglected or ignored. SAFETY PLAN.
Work in'ury
Loss Control, Safety measures Full compliance with OSHA regulations.
Inspections neglected or ignored.
Work injury
Loss Control, Safety measures All employees riding in vehicles must wear seat belts.
Inspections neglected or ignored. Drivers must follow all posted signs.
Work injury
Personal Protective Personal Injury Hardhats worn at all times on site. Safety glasses to be worn
E ui ment at all times. Gloves as re uired.
Personal Protective Cannot perform job. Employees installing cable clamps will be allowed to take
Equipment/Gloves Clamps installed gloves off while installing clamps. As soon as clamp is
incorrectly. installed gloves must be worn.
Personal Protective Personal Injury Proper clothin� and work boots.
E ui ment
Personal Protective Personal Injury Foimal monthly inspection of PPE Hyder inspection
Equipment checklist.
Hazcom Employee exposure Hyder Hazcom Safety Policy is on site in the field office.
Page 1 of 6
,�•
�
��
f.'t:}?�:�T�[.'C`�l I�)'4 I'���`.
Hazcom Employee exposure Chemical inventory list and MSDS will be specific and
u dated throughout the project.
Hazcom Employee exposure The hazcom will be available for all employees. Employees
will be instructed of the location of the hazcom acket.
Hiring practices Inexperience help Written applications, references, diug screens, tool
work comp fraud inspections, site orientation is required by all trades.
Orientation is given by the H der Safety Officer.
Hiring practices Inexperience help Applicants interviewed by HR Dept/Project Manager or
work comp fraud General Su erintendent.
Hiring practices Inexperience help Hazcom training prior to start.
work comp fraud
Tower Crane Falls, worker injury, Vertical and horizontal lifelines shall be installed to the boom
Erection overhead protection and tower frames prior to erection for use to access crane for
erection and maintenance.
Tower Crane Work injury, Are to be barricaded to keep other trades out of area of
Erection overhead rotection erection of crane.
Tower Crane Work injury, At no time shall any employees work over another employee
Erection overhead rotection erecting the tower crane.
Detail Crews Falls, worker injury. 100% tie off when exposed to a fall hazard great than 6'
Fire hazards. andlor within 6' of the leading edge. ALL EMPLOYEES
Overhead hazards.
Detail Crews Falls, worker injury. Inspect floor below before start of work for: Other works,
Fire hazards. fire hazards, equipment, etc.
Overhead hazards.
Detail Crews Falls, worker injury. Baker Concrete to cap all rebar prior to employee exposure.
Fire hazards.
Overhead hazards.
Deck Forming Ops Falls, employee 100% tied off above 6' and within 6' of the leading edge.
injury, or illness. Hazard line systems to be used. 100% tie off to be used
outside the hazard lines.
Deck Forming Ops Falls, employee Housekeeping kept regularly by Hyder and Baker
in'ury, and illness Construction
Tower Cranes Employee injury, Tower cranes are not contract to Hyder but will be operated
equipment failure, by Baker Concrete Construction up with contract
collapse responsibility for contracts on cranes to assure of a 3rd party
inspection after erection of the tower crane.
Cranes Caught in between, Company trained and qualified operators.
damaged equipment,
damage to structure.
Cranes Caught in between; Yearly crane insnP�t;r,,, hy�„t�;�P �P��,�P. ��r�;;�h?�� uru
� damaged equipment, daily logs kept by operator and Hyder Superintendent
damage to structure. equi ment manager.
Page 2 of 6
e� .
��
��
t'C_��:�T�.I_�'t_`T[�..��? I���`.
Cranes/Mobile Caught in between, Craz�e radius flagged off.
damaged equipment,
damage to structure.
Cranes/Mobile Caught in between, Back up alarms on all cranes
damaged equipment,
damage to structure.
Cranes/IV1obile Caught in between, Overhead clearances checked.
dainaged equipment,
damage to structure.
Cranes/Mobile Caught in between, Assistants to the operator: Spotters, qualified flagmen and/or
damaged equipment, radios.
damage to structure.
Cranes/Mobile Caught in between, No personnel hoisted by cranes.
damaged equipment,
dama e to structure.
Forklifts Crushing employee Trained and qualified operators.
in�ury
Forklifts Damage to the Back up ala�m, assistant to operator for backing in blind or
equipment or maneuvering in tight areas.
structure.
Materials on roof Objects falling. Area below will be secured and marked as no access
alid structure Worker Injury (DANGER)
Materials on roof Objects falling. Trans picked up regularly.
and structure Worker Injury
Materials on roof Objects falling. Oxygen and acetylene hosted in proper carts.
and structure Worker Injury
Access Falls, worker injury. Ladders to have monthly inspection tags. All ladders
Third party liability. inspected before each use
Access Falls, worker injury. Ladders tied off with rope or chain.
Third arty liability.
Access Falls, worker injury. Ladder access to comply with OSHA regs.
Third arty liability.
Access Falls, worker injury. Rope at all access ladders to lower or pull up tools and
Third art liability. materials.
Access Falls, worker injury. All trades to use our ladders.
Third arty liability.
Fire Prevention Fire,personal injury, All employees trained in fire prevention. HOT WORK
equipment and PERMITS PRIOR TO ANY HOT WORK.
structure damage.
Fire Prevention Fire, personal iniurv_ FirP Pxt;n�,,;�hPr±��,A��.,,,oa ..,:.,.:.. ,�� r_„ ,__. . ,
., „ __b�......,� v rJ1GLV\+U ,��«���� �� u� a����u� worx.
equipment and
structure damage.
Page 3 of 6
�,�
���
�.'�_)�:�T���{� TIt��; I�F�`,
Fire Prevention Fire, personal injury, All torch sets will have backflow valves/quick connects
equipment and attached to gauges.
structure damage.
Fire Prevention Fire, personal injury, Fire blankets where necessary.
equipment and
structure damage.
Fire Prevention Fire, personal injury, Approved type safety cans with antisplash screens and loaded
equipment and spouts.
structure damage.
Fire Prevention Fire, personal injury, Fire extinguisher on all cranes and designated area trough out
equipment and the building.
structure damage.
Fire Prevention Fire, personal injury, General Contract to meet standards for posting fire
equipment and extinguisher every 3000 sq. ft.
structure damage.
Fire Prevention Fire, personal injury, Trans clean-up on a regular basis.
equipment and
structure dama e.
Wall and floor Falls and worker All workers will be trained to tie off when working within 6'
O enin s injury. of the leadin edge and/or above 6'.
Wall and floor Fall and worker Guardrail installed around all major interior openings,
o enin s. in'ury. including elevator shafts at each floor.
Wall and floor Falls and worker DO NOT ENTER tape installed 6' back from temporary
o enin s injury. leading edges.
Wall and floor Falls and worker No unauthorized personnel allowed on roof or floors until
o enings in'ury. released by Hyder or the Site Safet Director.
Utilities/Electrical Electrocution Electrical color coding program to be used for ins ection.
Utilities Public utilities GC to identify underground and overhead wires, manholes,
service damaged, etc.
disrupted,
electrocution, fire,
ex losions, cave-ins
Utilities Public utilities GFCI to be used for all temporary power.
service dainaged,
disrupted,
electrocution, fire,
ex losions, cave-ins
Water, sanitation Hepatitis, disease, Clean water, containers, and cups GC will supply and
worker illness maintain ort-a johns.
Page4of6
; _ �
�
��
�°(�1��T�Ir�=`TI��'� 1`�'�`,
POST ACCIDENT RECOVERY PLAN
l. PRE-PLAN
a. Anticipate your needs as work progresses.
b. Have a plan and train employees.
2. WHEN A FALL OCCURS, FOLLOW THESE GUIDELINES:
a. 17etermine the seriousness of any injury to the fallen employee. If the
employee is unconscious,bleeding, and/or pain in his back, etc., call
emergency services if needed (Ca11911).
b. Assure a clean access path for rescue team.
c. Determine the most effective means of rescue.
d. Protect the rescuers from injury first.
e. Stabilize the injured employee if possible prior to moving him to prevent
further injury.
f. Lower the employee to a safe area.
g. Re-evaluate injuries, if any.
h. Transport to the designated medical facility, if treatment or a drug/screen
is required.
i. Check fall protection systems immediately to determine damage. Replace
or repair any that received load.
j. Remove the employee's full body harness and lanyard from service and
have inspected by the competent persons.
k. Always conduct an investigation and document.
3. RESCUE EQUIPMENT FOR RECOVERY OPERATIONS MUST BE
AVAILABLE FOR USE IN CLOSE PROXIMITY OF EACH WORK AREA AT
ALL TIMES WHERE EMPLOYEES ARE EXPOSED TO FALLS. THE
FOLLOWING EQUIPMENT MAY BE USED FOR RECOVERY
OPERATIONS:
a. Ladders.
b. Cranes with stokes basket or personnel work platform.
c. Scissors Lifts
d. Arial Lifts
e. Descent Systems
f. Never attempt to lower employees from a point above them without a
mechanical advantage. (One human cannot hold another).
g. If you are not sure of the rescue situation, do not hesitate to ca11911 and
let the fire department rescue employee.
h. Hyder may assist with cranes for rescue of other contractor employees but
not only under the instruction of the Controlling Contractor.
Scope: To provide the safest work environment for our employees and surrounding
workers of this jobsite.
Page 5 of 6
.�
��
�
�
�.`(;?1�:�T�.I_'(. T'[�l`� I'���`,
Equipinent: Full body harness, 2-six foot shock absorbing lanyards. Secured Anchor
point will be used with inline shock absorbers, and rope grabs.
Training: Hyder Subcontractors and Hyder employees trained in the con•ect use of all fall
protection equipment. All employees trained in Hyder protection policies and
procedures.
I�iscipline: Hyder wiil discipline any employee not complying with Hyder safety policies
and procedures and/or jobsite rules.
Incentive: Hyder has a quarterly incentive program and will reward employees, who
have not been disciplined, or have a recordable or lost time injury.
Fall Protection Procedures: All Hyder& Subcontractor employees will be 100% tied off
or protected when exposed to a fall hazard.
Fall protection procedures may change as job progresses to protect employees from
unseen hazards.
Page 6 of 6
. F`t:Ui I :CC �NTERPRISES FF�X N�. :97�?�2.r'753F] �pr-�. 06 2'd�6 fll:53.F'M P2
. . i
� _ .
� CC ENTERPRISE5 - TRAFFIC CONTR�L SPECIAL[STS, 1NC �
Confiracfor, HYDEl7 �ONSTRUCTfQN . PAGE #2
� Project; VqIL FRpNT DOOC� (Ml�� CREEK CIRCLEj
Method of Hand)ing Traffiic; TI�UCKS TURNING ON � I..ANE ROAD
. ' PREPARED BY; N
��- UI/.' i
fn.�i. r�••r rlovf �i�l%h f(J�' �y �
. ' . � • ATSSA TCS NAME DATE •
WILLpw�oqb . � S
L�?i � .
��
. . 0,9 ,
m�x,x: O
� iweMNC: <�,
oN
• � , .
_ ,�� ?�O+ . �� � .
. � . . �.".�-� �
- E FOREST ROA�7 � 200' � � . '
. �
,200' � .
WORK .
. S�
��� ""�`` ENTRAJ�lC�
ONIM1W •
���5: .
� . 1• GONTRACTOR WlLL HAV�TRUCKS TURNII�G ON AND�FF ROAD Ai`�fVTRANCE TO WORlC 511'E,
� . 2. FLAGGER AT E FOREST RD AND VqIL RD lNT�RSEC110N WILL ALLOW lOCAL TRAF�fC TO PASS THROUGH
. AND CONTROL DEWEf�(ES TO TWE 51TE. TH�FI.AGGER AT S!1'E ENTRANCE UVILL CpMR4L TRUC�<5
LEAVING 1}iE 51TE AS THkY ENi'ER THE ONE WAY,
51GNS;
� 2- TRUCKS ZURNING p� �{Wy . 2-FIAGGER SYMBOI � �
. � ��.
� �`,'��1 :CC ENi"ERP�IScS FAX NQ. :9702d2F53(3
,+� Apr. 06 �29�6'31:5oPt�1 pi
''i%1 1e� ` '
��A�
� �tH '
� 51
CC ENTEI�PRISES - �RAFFIC CONTR�� SPECIA�.ISTS, INC
Cor�traCtor; HYDER CONSr1�UCT1�[� PAGE #1
ProjeC�: VAI�. �RONT DO�R (VAIL VALLEY DR1VE) . � �
Method af Handling Traffic; 7RUCKS TU�NING ON 2 LANE ROAD � �
. � N
• � �� �{ � � PREPAR�D BY; � W E
• . U �rint� f na�r. !l (1b' OG'
ATSSA TCS fVAIVIE pq-(� S
' nn+uia ' �-r--`�`.�_ +-_+�� .
nm.n�c �
ON Ntw Q .
2��' � .
_ y
. �
. y� }
'�` � . . .
' M�
tUf�NUU�
ONi
200' . �
. , . , � � .
. . PAR14Poc'a � N Q .
tor � i�,
�� � . `�r:,, .
. . � n
. . "41
. A�r ~�
• . ! �� .
� � G��q,.�,u�.noA° .�oo . �
. _ .�� . .
�vor�s: �
t. CONTRACTOR WtLI.HA1l�TRUCKS Tl1RN(iVG�N AN{7 O�F 1/q�L VAl.LEY DR„ DURING WQRKING HOURS ONLY.
2. FIAGGERS ON VAIL VALL�Y ROAD WiLL S'fOP T�AFF�C�pR JRUCKS NRMNG.
FLAGG�I�ORI GRAi��t1 wo��r nnnn�x,��� �T,.�,,.�,....- --- -. -
.-. .�•,•••,••..r,�, ,y���o�vr �t<uc_KS t-UI2 PARKING LOl'TRA�F�C. �
SlGNS & Q�VlCES:
2-TRUCKS TURNING ON HWY 3- FLAGGERS SYMBOL .
-`���)
��
E¢gineering,Inc
s1m w xou,sm mp
Aev.n.�CO 80(IU2�1838
Pxx�3Qi42?J4pp
Fa 70i4227900
�
O
�
�
V1
�
H��1
�V
�
o�/neee�.oesrt
VAIL RESORTS
DEVELOPMENT
COMPANY
AWN.COIABA]10
42�40 D
ARCHITECTURE
��a�
..�ma+.+,.��
�,�
����.
•`�� ��j�9
�OP
� I O�
{ o
5 �d
Site
II I I II
SITS
CONSTRURCTION
FIltE DEPARTMENT
ACCESS PLAN
FDC06.A
�•��-��
��
Eagineering,Iaa
s�xo w po.o,wn mo
��wh�O 80001-1938
R�30i4L+Ji00
Fi.c 30i122]900
�
�1
O
�.
�
V 1
a
�
�
�
ORNSR/DEVAOPHA
VAIL RESORTS
DEVELOPMENT
COMPANY
APoN,COIABAD�
42�40
ARCHITECTURE
����
..'���.,.°W°'�.�..a�
.�.�..�
�.�....�,.��
���
����
N0:2D693.03
� ��9
aOpP
� 5 a 6d
Sik
II I I I�
SITE
CONSTRUCTION
FIRE DEPARTMENT
ACCPSS PLAN
FDC06.B
,.=,o.-o.
�
7'EMPORARY REClAS61FICJ1110N
4F AS8EM8LY�lCY ROOM&
e�e. a�sort ros�oxur,wr meo e�ooaivwns. a.waa adaieieiax ru e�aoo.
0. ClRE11I lOSRD OCGRAIR 14tD 6!!0 OOpIPAI�x OL GIR�IC CGIEIRICIpN Mtl E cJ00.
�.� 111lIfitN ACQSlIF ROIIIE.
� —� �xxnw mn�a wr.
IA
EXTERIOR IXIT
COVERED D(R
STAIR SCAiFOLD
(MIN. 44�
N
IX!T t0 LOBBY
�
No1Es .
TASfE NC pIARt Po!11E WlA00f6
11LL t SIOlfO N MIlADOY G
RH SWING DOOR IN GYP. BOARD
PARTITION TO STRUCNRE. PROVIDE
EXIT DOOR MATH EGRESS HARDWARE
AND SIGNAGE AS REQUIRED.
i �
I �
'STAFF ONLY' EXtT DOOR
WITH PANIC HARDWARE AS
REpU1RED. STAFF TO EXIT
T� ��.
1 wu�ruN AocESS�s�
�ROUTE AND EI(ISi1NG
DEYO AND CON5IRUCTION
L I EXTERIOR
'
�'
►1AINTAIN
�cimNC oc�r
PAiH
NOT—RAiED
DfIT ABOVE
LEVEL t
—NEW PARTRION T
- �
�� _�
S _ �
�� t
� °�! '� oamNC noo�s oN xo�n-oP� uflnca
lI CONNECTED TO FlRE ALAR11
� �=T TO BE MAIlRAINED DURING CONSTRUCTION.
E)Uf
EXISTING LODGE AT VAIL & INT'L WING
CONSTRUCTION TYPE: IIIA (ASSUMED) ��
B
� y �
.> _ 1
YAINTAIN PROiECiED COVERED TEMP
PASSAGEWAY AND TEIIPORARY STAIR
DURINO CONStRUCTION IN ACCORDANCE
WtTH IBC 3306.7 NEW OVEI�IEAD
PROTECTION TO BE PROVIDED WHEN
OVERIIEAD PROTECTION IS REQUIRED.—
EXITING IN PLACE AFfER
DEIIO OF SOUTFI BUILDING
NEW SPA LOWER LEVEL
CONSTRUCTION TYPE: IA
� �����
CEP01 � "_3�'-0"
D(1511NG
�POS�ED EXtT
rost<so
OCCUPANTS
� A
' EXISTINC DUT
...�. :°��:�
�_ , ���,� 4 .
��1
15' 0 15' 30' 60'
� �
�
�
� EXI5IING
POSTED EXIT
aosr <iu
OCWPANTS
C
EXISTING E1QT
�
?OSf �200
OCCUPAItTS
D EXIT FRON VAIL PLACE ON
BELOW.
onmNC ocR
e�.,� TEYP EGRESS STAIR.
L'"'� 1 12' STAIR 0.2 = 360
OCCUPAttT CAPACITY.
r 'r
_
3fT HAINTAINED
CLEARANCE
NEW CONCRETE/PAVED SURFACE CONNECi1NG
C04ERED PASSAGEWAY AND TEMPORARY EGRESS
STAIR (OCT. 31. 200B)
NOTE: AREA TO BE I�PT CLEAR OF FUMIUBLE
OR COMBUSTABLE MATERULLS POST'NO STORAGE
ON DQT PATH BY ORDER OF TOV FIRE
DEPARTMENT.'
TEMPORARY YECHANICAL AND
EIECTRICAI EQUIPNENT ROOi1
(PER BO-016 6.14.2006 PERAIIT/ASIB-001)
WRH EXIT TO EXTERIOR EXIi ROUTE.
FIRE DEPARTMENT AND
EMERGENCY STAGING AREA
� EXIT AT ONE VAII
PLACE PUZA
FENCE AT CONSTRUCTION
S,w,'�ING LINE
;�,,���
l
%
i �
ENG[NEERING, INC.
5420 Wneo Row,Su� 200,ARVwn,CO 80002•1838
Pxo�303.4227400 F�x 303.4227900
li�
0
z
z
�
0
�
Z
W
3
�
V�O
u,O �
�
a° .—�i�IoMi�
U3���
Uj� �
��� �
�
� °
3-1
�
O C
i--�i �
� o � �
�, o �
�+ ; o U g
� � �
O A � � J
� � �
w � � o6
� �
� Q
�
�
�
o -°o�
� � °
� U
`�' A 1 >
< �'� �
�
� � � �.
J ,,�___ , :� � .
.e € 's � x �'�
!
� r _"�-- �sL,�ugo ca+smucnan am,wcc � /
� ��St (SCE)SFFLY9ElNSfALLID AND , 9LT CE . � � I PRO�� \ .
YAINTAINm AT ANY CCESS PqNT� �
� �b •f��� -a•[ 7XE 91E ALL TFAFlIC _NNG 7HE 51 ��. ..N ��g5 �
\ � r" ALL BE dREC7ED M SCE �, � '.� m�•r SOUT7 TOWETCb0.
E � � � \
`�' �o,� �� � '� � ��
s
�,j, ��. s �� �ie �� --- I
\ � . -
� "° �<_ � �-
���� �� � �� —_ _
,
, _., tn 'Fltirj . -- ' -
���.�. .:.�� �g ,-�. ��.
� � -._ ,
irr
� 1 i ., /^ _
t� m i u�
< � (
i �
'___ ' ..--�i ��yT�� � ..
i,, i , .
� o �
onsnNC }�--; � � D. 1, �+a 4 �.�
�EGETAlION '
'� .
TO RDANN I �-'+ � - ` p C9 '
UNDISTUflBm a�� j` ' °F - 0 4 '.-��:
'f
+yr'�" � �UNfiik4 UNITS!!' �''.
U.SF.S I ?@��
� � ��. �� ..��- r o�� '
b_
1
i �ppA�pS00� I � _ _J�- t .�z.. J '.I -
BOUlDiWY � � _'L - -- �'2�` �'� ~°:.�. _ '
- � � " "
� I s:` , ' �-, -
�a.,�, �,
�cnor� ' i i uaR ss. � ,�nr��e �` � �,: awcts _
AT ROCK�EDCE i�+m�V i ��� 1 : UNIT 12�1 �
n�,-«� � ,' :� � �� `�
_ .(5EEtt1� I � � - -- `m�-� �1
� � �`� ' � � " -- ' - .. ,
, ,. -. .
...HA(p TE��. � . r: �i '�i A:i STAqNC D MATEISAL STOkACE-�Ia� .n, i
{� _
_ ��'.,'} �,v.�� �, i `'�wsmrc�`'-y.. ,�,`�?-r •y /ST�p,N� ^ ,G
. '�� '
.
"�""'�.i. � VE4iTA110N... q�4H _ � OOS7INC ��%.1�i
� �6"4'"s--1�� TO REMNN yE(�E7ATON
�'� � UNDISIURBED
_ i
' ., 1■ ■1 ��-7l�""�•. ��O TO REMAIN o- w�r
� �+' � �.,,� � UNDISNRBED
U.SF.S� ,- ,..SICfFENCE � •� `" :
� ,,-�,�,.� �� ,: � ,v,,,�
�---------= -_ . �.',�� �. `
f
�__-__�__- . .
_' � _
. . �� "+t �:. ---- `
♦. ..'�4,x--_.:"�-..r�� �'usvs.
�_a— �� ._...
�asnNC�c��non ���� . - ���
ARE/S TO REMAIN .' /'al����1ltlrtl��l��ll� _y
UNDISNRBED WRING ' __ �, �/��
ca+smucnon �
vrtarasm ���
r�ci'°°' �i
BQINDARY . �1 �
� SILT
� \\ �.
� . ��
�
. �
ti� �
__ `
I y_
'
-- _ � SI TE STAGI N G AN D
-
- ACCESS PLAN
GRAPHIC SCALE � ' - � ,
y ,m.�, H ASE -2/� - 2007
��c_�a n . .. -
LEGEND
O O O n�/�n O O O PROPOSED STABILI2ED -0 O 6 7ROPDSED CONSTRUCTIDN PROPOSE�CONSTRUCTION -
17VE CONSIRUCTION ENIRANCE
O O O�O O O O FENdNC ^.12}jD;�; MANAGEMENT OFFIGES
PROPOSED CONSTRUCTON
�(�pypqyy/Tpy,yyfpq�� PROP�SEDMR7ERIAL ■�I��I��I��I��I� PHASINGBWNDARY
—iT—aT— PROPOSED 9LT FENCE � � STORAGE AREA
REVISIONS TO 7HESE PROPOSEU EROSION CONiROL
THRd1GH UT IHERCONSTRUCTI NESEWEN�NG PROCESS a 4 a��ES a 4 a EXPORTEHAUL ROAD
GENERAL NOTES ST�GING ANO ACCESS NOTES:
1.SEE GRADINC DETAI�SHEETS FOR EROSION CONTROL DETAIlS AND NOIES. 1. LOCAL AND CONSiRUCT10N RCCE55 fROM GOL�PEAK TO THE VISTA
BAHN CHAIRLIFT ALONG THE SOUTHEAST END OF THE SI1E WILL BE
2.CONSTRUGTION FENCE BY FIY�ER CONSTRUCTON. UMITED. THE COLD PEAK ACCESS ROAD AT 1HE VISTA BAHN CHAIRLIFT -
WLL BE CLOSED DURINC TNE 2007 CONSIRUCTION SEASON.
3.WATER OUALITY AND GONSIRVCTION DEWAIERING BY.�NN ENGINEERING/HYDER CONSTRULTION.
2 VAI�RESORTS DE�ELOPMENT C0.(VRDC)TO PROViDE MPROPRIATE
4.N1DER CDNSTitUCTON TO PROVIDE ALL THE NECESSARV EROSION CON7ROL RENSIONS DURING ALL AND ADEWATE SIGNAGE FOR ttO5URE5 AT GOLD PEAK AND AT pLL
CONSTRUCTON PHASES/J!D PRONDE SWHMP(OLLOVANG CONSTRUCTON COIAPLETION. ACCESS POINTS TO iHE SKI YARD ABOVE TME CONSTRUCTON SITE TO
1HE EAST,SDUTI AND WEST OF PEPI'S fACE.
5.ALL INLfTS IN THE CONSiRUCTION AREA SHOULD BE PROVIDED YATH EROSION CONTROL PROTECTION
AN�AS CONSTRUC710N PROLEEDS,ADDIPONAL INLET PROTECTION MAY BE REOUIRED. }, CLOSURE ABOVE HOCKLEDGE ROAD MA1H BE GATED,SICNED AND
MAINTI,INED BY 1HE CONTRACTOR DURING CONSTRUCTION FOR ME MRL
6.CONSIRUCTON EIAP�OYEES WILL PARK OFF-SI7E. CREEK ROAD CON57RUCTON ACGE55.
7.OFF-Sll[RUN-OFF M�Y BE MEAV1'AND IS TO BE CONTROLLED BY VAIL RESORT$DEV C0.(VkDC), {. '(ME CONTRACTOR IS TO PRDNOE ALL THE APPROPRUTE ON SITE
SICNAGE FOR SKI YAR�AN�CONS7RUCTIDN AREA CLOSURES. NOT
&DE-WAIERWC OF THE BUIIDINC FOUNDA710N5 N9LL BE PRO�IDED BY A SEPERAIE ENGINEER. �IMIIED TO PLA2A5,BINE 7RAIL5,PEDES7ttIAN WAU(WqYS,ETC.
9.91E GtEAN-UP AND ADJACENT PROPERTV PROIECTON SHALL BE THE RESPqJ51BILitt OF iHE
GENERAL CONTRACT�R AND NAINTAINED,YMEN NECESSARY,PER THE T�WN OF VAIL REGS.
vaansow.owcvawwnov-s..,w+c.ncc _ a uxm�.asnM..�m
L
��, I I°i, ��� a "� �,�_-�" ,.-� �-• r
� , ` ��, � `��� �;
�' 1 � r r /, �f�±L z l��. CHWSTIANA
■.'i .. �'� ;i.'c�� _.. �v �,p .�\� " �� �'.
-. 1,1 -�� _� Y� j`. ._ '�� , 3 \ \�� � ,
fl' :i � �L-- "' � J r �,:. � ��" � '- �'" .0 m,,p � �,\ r--J � -
,ce n �/� F L I
...`-..� � � t N PN �or � -. �
j ��. ' ' �i�`- ,AHDSn11l'� ' .
�.� i mW�na7K,Yelc • 1 '�5 io a��fq ° ��� �� \ ' � i LOT D.BLO�C 2
�' � uuemuRegn:: � � �' ��J
^�.� svA #�� � . � aE V,u� "'ia� '�y' ``� �,�" 1 ��=�� r \ ,
� c, - a� euu.omc / � � ��� , ��
. . � �� ;, _ �J, ���� �� --- - --L---
� � � � - CaLDEN PENC Hp15E , �� n/� s �� '�'g "—"
� �� --
_ * .�. `� LOT Ct / - � ,� �t� \ �� . a- ...
. �R_ , ..-. � .,' ' _ � � . - 1 \ � �..
' �i
f,
4 fl f _ ! �� _., `f/'��� � \J� �' -
r R:�� i -, i >r,
� �
�',5, . �, -� � � _... c �� \ .
`,
��!G`�... ..- 1 . 1 . � . .. x� . -__ 'i ` \ _ AIL�4LLAfiE FlF1Y1 FlLINC � TXE CON1RACttNf IS TO.
i _
�', �v.�, .�,t-h~ '� - ��.5 - �'��.=. - �` '\ _ .
V
' �\ PROVIDE MPROPRUTE
„�^ , " _ � •'�:�� . + -' . CL�AIRE ANDP�
,.tS. � A
. ,. � ��y'. �' ._ �`'; ,m�. . � ACTOR IS TO ii- \\ . .. pifl1571ANA WT-OFF .
' ' ."� �` '" 9� : •-. � a .���I � RONDE APPROPRIAIE ', \\,
_ {'� .. � 9GNAGE FOfl PAT7 El�STI ~•VECEfA
. } _ .� � � ,_ ., !"., 1 ;a�wno�ccESS ur m \���� -
, r�. � > � . � _. ......... .
`i �
� : _ - ,,,.- / ` _ ; , � s isY„ •.�``u°� �:- `��- -{� ' --- _
__ �l ��5��p N _
4yt N_".i"'BED __.:�� - 1
«�;. .� n �� , � �T .�.. -o ---_ -
i �l Y�� _ � :' � � ;t� �'° �� '� � � � _
.
� �"• � ' �� _ � . v � PAR B
� � � � � _� � ° �j 3 ,�uif R e�oa�t T�i � L0T 3,BLOCK
• e __ ._
i \
� . � , --- - -�a� �1 _ �
� — -- -----
.,, �.. -_ -' �oT,.
�
� ..
� � ,, , .....r... , _
.......,
�. . ,� : . , '':� 1�%, i(—
� � ' '
. �. _, . , , � _ �
., _ � : �
:. , , :•-�{ -
� , ��- ........ 1 ::�4 1�� ��,_ ��-
, < -' _ 1 ., �, . 14, 1 _ _ �
,
, , , � a � ��
, �
\
J .�`..� ��. ° ' ... . - > J._., :... . !PI�CAST� 1� , . 1..... . _ __ _ .
� �
v... !corICRETE .I� '.� �a � �1 '� �."_�"_ �\ ' dRd�
'u S �� `. . - �.,: .r,.. : LIFf �i�� �.. � �`�' DnDE�£LOPmn� � � M1LL�RE
j.r� u4 � '. Fy
i �J ' � ;
�, �- c; . � , ' ....� :. HWSE�i �. .� y� 'i I1 AREAS TO REHAN/�� ' 'i
� ' _.�I� " �Y � ' � E ����ne� .� .... .. _ -"
� � `,i � - -- -- - -
S�'^Z'i�` 3* T ' 1 � ?l� /
Y�'nl 2{ S...JV 4 ��n,�3 - : �� I � , �� '�� �� �.......... . ... ... "II �', � '\_....� m�za�umnnm
Pca�sm�ar Z z.? �s� . '�'� .� ' � � ` sd � 1 /' i ' .. . 1 � VAII.RESORTS
MANAGEMENT �;..�.�y��ay<., �, � I I� �Ii �r'./��" �or 4 e�oac t , oT 4.BLOCK t
�� _ , ��. � �` ` ��� , DEVELOPMENT
% . . � � I� I COMPANY
\.. ��4��' "�'�r���X // � ■�N$;f��/ .�� . . I . \ t'ON.COIARADO
+� �.�X,2i'?• � I �� �� t0T 4.BLOCK.1 . \ C
/� - � /� �f V � '`
� +? � 1I 1/ . L 11�` tir.��mv.+ .a�ow
' a.�<`;
, a � : fi I /_;'— � _� � ' 42�40
���T.p� � yk��� ���`� ' ui k/ . . •" �.\ '�'- ARCHITECTURE
•5��. � i Y . 1 ?1` . _� �' '('-__ �
: �
� �
. ; � �
'�. , e : n 1 i _ �� i
\, ' ' ,� 1' \ \t. � �'•i _ ... �
-.. � _ ,
. . I � •.. ':
r�or ...... . � l . \ � \\
i
coNSm�ucnow�ce - . . , I ,�;,� �:� � .tor n.ewtrc--�� -- ' °"•
� ro e6�-�oc.�Tm ' . .. . ' : ' ` w < j -
�/
oEssu� . .:..- '� ' .�
� e�oD h v To :.. . - g (rn) -.:� �� . � `::.� _ . �1� .i LOT 70,BLOC u.. ...a,.
v�� .
�� corrsmucna��nu � }::. I 1RACT E �� ���? '-i� �'�,I �- . . . //... . . �.
�� � . � # � � `�\ . , i �� .�. � 1 N.R..��..,.�,
�' cwrnNC � , �j ��' � j ..��.,�
� FlNIS1j� � ��� P� `�� `� ` `� II�
•
` ' � ::. ��:�uncmux
'... �:� � i..
�, \ �... �: '���../e 1,�, . .. ��� �. ..� .` I
\ �.'� � .�/ ..coxsrtNtTi ..FaleE �' � ' �.''�pR� ,� +_� � I PROJ£CE NU sssa
� ' e `' � � �, ISSLF ISSLF.N ISSUF.
1.
�+:!:�. �. ..._ TO BE PE ��ED . .. ..,. rvo. nnxs. orscamnon
FD �� .�
_�-`
\1.� ..AS'NECE55 Y lO �. tl� � �� ' .. \
�`�.. °a� ot W1�A6 tdlSlmlCipN
s:`.�` �--------- ■i��i��i u.sv.s--'- cwrsmucn ut� $'� � ZA � u* � ,�•� a.m.a ancrosrxar/
♦i��i�� �.<�, �����• •1i���� ��i��i�� I� ,���. s� .�� f - , rari mm.
•-��,_"....r_�. 1l\�i��l� I � :�t ��b CONST. � .1 �. .`;- � 4 DS.t5A6 &DGUEPfRFSP/ L
., � i ,
��t _— `� .,�. ` - �l�RN�ER �\ LOT 73,BLOqC t 1 _ rorimxst.
J . '� r mbm rat75 pw
u =��..�— �.__ ,� w P'`�►�� \ - j _
�: �. i - �-_� � -, ;��, �.
_ .$7 FENCE(7YPj �= �� � � ` ' \ � ryLOT 14,.�OCK 1
I "`�-�—'T� . � i
__ i ,, �. � i
a�oriocw s �
... � 1' � - �I - cor�smucnow eccESS ��. .`� � \, � . .
,. ONLY.AT COLD PEAK �\ t
,-. . J ; IURN-OFE'($EE INSETi � � .
�' � i _
�- �
_:��
_ +��^\ I, �+ �y�
,...._. ,m /
. .. - �."_ . . .
.. - - .. - -'. __. . . _ � "I Ql\ . g �
.` .._ . . \ � tr ,
_.. , _
,. .c
_ �
...� �. '_' \�.._ r, --
ROCKLEDCE ROAU '.- _-. -�' �.... � .. . - �r N � .
� _
"_.' " � . V T7E CONIRACTOR IS TO ,��
PRONDE MPROPPoA7E
�� SIGNAGE FOR ROAD � ;
. " �PO�p . � CLOSUFiE NN ACCE55 _
4
/\ ,
' y .__
' / �
_
_ / - - � anovosEU Qes
/ \ z
' / �ESSERY BMR�
. '- �\���/ � ANU GAIF.IUCARI AND SIiE
..: '/ �.� PR�OSED " .. f��157RUCTON ACQ55 ONLY
. iNE CONTRACTOR IS TO ' .
,... R����E RO �` '_- BARRItl25 ANb AIED pRONOE APPROPPoATE ' I I
-. Ap a CONSiRUCTON CCESS SICNACE FOR ROAD � � \
� � CLOSURE AND ACCESS - �- � � .._
- I '
S1�
_ - _ Mcc q� - r`� �'� SIT'E STAGI:VG
RO� ��^ � A��D ACCESS
R ROAD ACCESS INSET �s� �' P�v
GOLD PEAK ACCESS SET
PHASE 1,2007
CO6.D
SCALE �._��
0
�
� ,> ,- ♦ -i ., � �\\�� ��`� �� �� � � � `
� � �� �� `.\ � � �`��` � , . ;��.� "'__"'- `� � _ `.`�� ����� ' . _ __
��/ -'/ � ��\ �\ \ � \ yc� � �.`� l\\ *o. � �'__ � ` - _` �.... _ "-'__ _�� ��� � _- ____-- lt -
.., ' � ; _ . _ _
1 � / / , ` \ �.; � \\ .� �` \ �... ���` \_` �� _'__" _ ___ ` ` � ` ' I - ___'_ � �__-"_' � ��_�l`_
V � \ � � , \ \ \ ���`\ \���� �� �� ` \��y � ` � `_ \` _
. _
, �.
' 4 �` �.\���``` �` '.. ,\` \ � \� .\.. y�`��� r �.\ , .�i , �, �_ � - - -
'
. �
:
_ , I -` , _ _ ,
i' `� /� �.: l � \ ` \ �� 4 \ l ��",.��'��a'+.` -I \ ��� _ �� ` � � ` __� � �,_ �� �___ �____ �
f \_ � -y \ �J`�� �` ` �-____"_" _` �` ` � \\ � ` _ `\ 'i"\
. .I �'- �� \� `\ � �\�\\. � � \��` I --- � � � �� ��� '- _ -'- � _ �- _ �-, � - '
Y""� �`� �` �\\ � \�\ �.,. *\,\ �\\ �M`` \\ ...�.I �� ^�_`�f�, ` `___-____--_ ` ` ` `` ``` `` '_-- ` `` ` `` ` ` __` ` _`` ` _`'� ` )
,_ _- I �> >`�� ` `� ��- '- ��� ���� �� � '- __�� � � ����` �-- �� `� . ��
� �� � �"- `�� ���� �` �1�� � �� ��- ��-- -- �� � � --- � ��
. ,\� � _� . � � �.�� ��-_ _ �_ , � � -_ ' � � ' � �`` • -_
� '' 7� ��. �'� � �� ��\ � '+i`l. �'_--- ,•� \� � ``--___----- _ ____ ����` ` ` ` � _`_ `_ -� �` �```` _ -- __ � I``- � -�_ ` � --
-'--- - - -_._ ' �1 � ` �. \ � `� �,� �,_ �'' � ----- _____ �� � � ---_____ � r�'� ` _______- � __ __ -- ___`- �,` _
" -- �.; '� -� �\ ��''� _ `�. ` __ �; ` � ------- -----`` � `\ �'�-_ '_ ,` � ��`�__-`___� ` `�_ ___--'- `� �� --_—
- - _ .s` `` �,.;,-��.., � :� _ -:� � , ___ , `�� � , ___ _ '„, , ��
- _ i� � (� �� '1 � �`\' .`` \� .+. �� �.� --� ��`�\ � �''-- - - `� ` � � ` ��- ' ` � ` ' `� , -_ _'- '`�� \ �_,—
'��� �� "/�' '� - --- �� _ , i �- `� � __ ' ' �� ����___ -___�� ��� ��
GOLDEN � , '��,�� � - . ,; ;\?\. \�,\, \`\`\ \ __ - _ .- ,\\- _ _ \-_` _''``` ` `_` ,`' ---= ' ------___- \_' `'_--
'��^ �� '� �� �, . .
�-,&'A_K \-� ,_--'" ' - • �' \- ` '\` `'�• :�,��. _-- �, l� ---- ---- _ _ __ _ -- ___ _ _ �" _ �` _- ___-=
`/ ' � �, ' ~• , •r\ � � \,� '` - -- ----- - �- -
SKI �I�9 _ '` .�' `�� -
i `- /
_o
� •
_ %; ,_ -'� -��; � ; � �;: .�:
�;� `--T'' -�� < '� ' - \;
//i �\ ``�/ '_ �1\ \ `�// w` __ ``�' F
/'� \ ���1 �1/ �'\',! `�/ ��.
� � � �
1 x, �
� / ��
i l �ti � w .
'_-_� �' � � y�i������ � : »_;
rti-�� 7."__ �
/ � � /
, ,
`__ _- � l
1 -I
1 I
�_7 �.� "��, i �
� - - ,
�_. , __ __
� ' '�t,�
; ;,�, , ,
_�_ ` `,� � f - _ �
�
�_�e� �(/�/�/j^��\ � rt '
ve�_�"- \ . r�
�_� �'� i
;�__�` �� --- -,
� - --
� �\� ��-_
_��� �A♦
/ �� �`°° ° �
� '"'' �`�
� � � �
� � l'
� __��� .
�:
-; ` -� .
s
i3 - -� ,`S
_ �
�
�_�-; ;�
,
s r � �.
� ��.
"..i� _ ��� t�
�/�/.[/�J1 4
r'.. __l-�i�.�__�`�'l \�.\'�.-
�
��
N�„_ �
N;���� �
���►�=����
�% .��.�-�e�- �r��.4�
�v7/ s'♦ N ,
��.��� P �,,•a �
�� �!v�e�� _ � �' �' ! �
�' �•`��� ��`:va - ` � `
.
����E�6 �',�.� �� i
��'� ��-� �`�:^��r� �����
��1 _ �E�
-i �r�+ ��►� t:� ``��`�� ���
� � - � -�
�w '��c� :� �_ »t�
��� ��..s �� �
� �� '° --- �
'��es �i7) , �r �, �, r; `�a
, �`
�� = i�r,:�5 ��� � � '� � �� -
,, t- �x�c�y�m�����¢. _ , ,.�q �s ,.
-�/��tl���^'°!'��,V�J•I��S'^:L4� _��.�\���II/`I���iaA� ��.\a�.✓
� �Qb�r-- - a=l 03. .�
r�r'����
�
�--''' =.` ;�;-';,__�; �` � , , ,, �� -- _. � .
' � \' � `�'� `'� ���.
� � � .��` - .7 --- � ` --
�\�� \ `\\ `\ ` \\`� �� .
<:, , � _ •,. , Rf��_'�. ,-�
` ' `�\ :,���, - ,
b ��= � �'__ -- �
__ =�; - ��;�� _ �' ____ ;_,, --- ��; <
�,-;� _;', �' ����` _--
�
�
�':
J �� �F"1_�-. '� ' �?'`�. , ` ' 81 _' � _ ���� �-�, ___i `` _.-. , �_=�
� •.� ,� � F � �;
, r' � t- ' . : .. .�r v � i`�� - t1 ,iiy�i i„i!! I,� ��� I� .���7 - \ �--�� '�\~ -- � �
-��z - r" ��u�� i �-,-�-__- i
a�, � • _ ' . . - „ �- rl� � �,,'•�-__�_�;� _ ,�,/���,,,- ,_ �� ,
fr � ��� ' _- '�� ;�, "�v - r= � I 'i �1j D��, . � �` '_`J ` " �� ��` ���
_ � ji � ,I��i Y - � - � .\��� �� ,�J��.,_. ��
.�� 'L . �l t__ S>O ` � - �.� -- r \� "_• �� \��� .,1� � ``'_ " "- \ T�^ `_ `, � ` _
����
� rG� __4 �1 .' h�.^�: . - _- - ` ,r . ._ 4 `'.� ' ' B �-__ - ` �`___ � _�-``�
' P/�.� � _ r-_� " � � ' _- — i� ~, �� ,y�'G' �:� ' C _ __ ��—.����A, �;----=�� ,� �- - =
_ .
, . .
�
. . - , ,
. � =�� - _ __ � _ , --
� ' �. I, � '
. '. ... . _ � �
,
�
..�: � ` � ' � ' � � • �_�� '�-,�' '
% ' � I 1 F': '� � J'-�� � . _
'^�•(1`, / � �""r� __ ' (� b/� v ���__ \ i �'� ��._ � U�
�.,,, � ...— � - l = ��.__ '� ' j -_ _ _ ' -'i`,' / _' � - % :' . , ; ��, �
� \ � h�� '/ ` ��� � �.' —,(f /,' r— ' �'_ - � '+
,\ —__—� ' :��.r '1 1 ' / ' , �' \ �I _�`� � j _ �
\ � `\ �____'� .i^�\\ ��\`. ,.�:, _''�:%� ' .�`\` - � i i �''1 , - �
} ------- �. . , �_ j P E E K'-�" � `•e ''�. " ' _,'�
- _ ��_� ,�. _ _. —_. �� �- _ _- E C. � C'�.� �. ' , �
� � �_ �V � � ���i . `\�`=��\J ./'�' � .i 't' � � ',��—l� � __ 1
— I�=_� -- '�-�:l�:� � I - :� " - p � " . -_ i � �, �;�
. _
.
_ . . _ _
.
`
� _ , " _
,, . , _ — _
I
, ; -- --_-_.. -- — — _
- - _ � � _ �f__-�- d _ _ _ ; V
_.
� - - _ - - - .. _
, _-- =---_ � - - - � --
- _ __ - _ - 1�EADOiI' — /9�:g C._.;` _ -' " , �; - ._ � SCALE: 1" 80'
__� � ; --, . ,- � -� _
- - �_ , ;-, \` ` - . , PARKING i ; � �. .
; ; --�•-,-._��o�,�__�-�_ _ _,, - - - _ - � ___._.--- - - -- --- -- � _.._- — CONTOUR INTERVAL = 2
J _ I
�1
O
O
�
�"'�
11
�
�
�
VAIL RESORT'S
DEVELOPMENT
COMPANY
AVON,CAIARADO
a2,ao
��w���,���
e�uai
�`�i� ,
� � _
f
SI7'EA
�� �,
SITE
si�
ACCESS
PLANNING
C06.ACC
� ��_�ar
VAIL MOUNTAIN
ACCESS
�.
LIMITED
PEDESTRIAN
& CYCLIST
ACCESS TO
vAIL MOUNTAIN
PLEASE FOLLOW
DIRECTIONAL
SIGNS T4
CHAIR 12/
GOLDEN PEAK
�
�
�
,..�` ,,,:,
� V ,alL R ESC� R �r �
� � .��x:,� . � �,��,_
Vail's Front Door
Summer 2007 Signage Key
Map: Aeriai Photo with Pedestrian Access Route Highlighted
Sign Breakdown (Please Reference Exhibit ��A" :
1: Single Sided, with signs A, B, and C: mounted on black metal stand with
sign post.
2: Single Sided, with signs A, B, and C: mounted on black metal stand with
sign post.
3: Single Sided, with signs A and B: mounted on black metal stand with sign
post.
4: Single Sided, with signs A and B: mounted on black metal stand with sign
post.
5: Single Sided, with signs A and B: mounted on black metal stand with sign
post.
6. Single Sided, with signs A and B: mounted on black metal stand with sign
post.
7. Single Sided, No Vail Mountain Access, Service to Pirate Ship Park Only!
Please follow directional signs to Chair 12/Golden Peak.
8. Single Sided, Heavy Construction Traffic!!! Please be aware and obey all
posted signs!
TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2135
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ALARM PERMIT Permit #: A06-0068
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-FOUNDERS PLAZA Applied . . : 07/28/2006
Parcel No...: 210108278002 Issued . . . 08/03/2006
Project No : Pr fOG �'d o.�-� Expires . .: O1/30/2007
OWNER LODGE PROPERTIES INC 07/28/2006 �64����0
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 07/28/2006 Phone: 970-949-9277
P.O. BOX 8849
AVON, CO
1060 W. BEAVER CREEK RD.
AVON, CO 81620
License: 668-5
CONTRACTOR ENCORE ELECTRIC 07/28/2006 Phone: 970-949-9277
P.O. BOX 8849
AVON, CO
1060 W. BEAVER CREEK RD.
AVON, CO 81620
License: 668-5
Desciption: VAILS FRONT DOOR-RELOCATE HORN/STROBE FOR FDC AT FOUNDERS
PLAZA
Valuation: $500.00
***************************************************************�**** FEE SUMMARY ****************m*******************************************
Electrical---------> $o.0 o Total Calculated Fees--> $2 5 0.�5
DRB Fee---------> $0.00 Additio�al Fees----------> $o.0 0
Invesrigation----> $o.00 Total Pernut Fee--------> $250.�5
Will Call---------> $0.00 Payments------------------> $250.75
TOTAL FEES--> $250.75 BALANCE DUE--------> $0.00
********************************+********************************�**********�***********************************************************�*******:�
Approvals:
Item: 05600 FIRE DEPARTMENT
07/31/2006 DRhoades Action: APPR Ok to sign off per Mike McGee.
**��*******�****************�**���**************�***********��*********************�*�***:�*******************************************************
CONDITIONS OF APPROVAL
**************************************�****�****�***********************�*************�*****************************************************�****
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2135 FROM 8:00 AM-5 PM.
�e:G�1�' /��,
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
*��**�***********�****************�*****�*****************�******************************+**
TOWN OF VAIL, COLORADO Statement
*�x*******�*******************************************************************************�:**
Statement Number: R060001139 Amount: $250.75 08/03/200608:30 AM
Payment Method: Check Init: LT
Notation: Encore / ck
1501
-----------------------------------------------------------------------------
Permit No: A06-0068 Type: ALARM PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
• Location: VAILS FRONT DOOR-FOUNDERS PLAZA
Total Fees: $250.75
This Payment: $250.75 Total ALL Pmts: $250.75
Balance: $0.00
**�********************************************�x************************************�*******
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
BP 00100003111100 FIRE ALARM PERMIT FEES 18.75
PF 00100003112300 PLAN CHECK FEES 232.00
-----------------------------------------------------------------------------
y -- �
. r
APPLICA ON WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI �"� , ��
Project#: � �
� QO Buiiding Permit#:
j' Alarm Permit #:
T1�WNOFYAII, ' TOWN OF VAIL FIRE ALARM PERMIT APPLIC
ATION
Commercial & Residential Fire Alarm shop drawings are required at time of
7S S. Frontage Rd. ap�lication submittal and must include information listed on the
Vaii, Colorado 81657 2" page of this form. Appiication wili not be accepted without this
information.
CONTRACTOR INFORMATION
Fire Alarm Contr ctor: Town of Vail Reg. No.: Contact Person and Phone #'s:
��,c'cy f `
-�c z�s� ��f3'-�� <<zi�,✓ L�..�.��-;� ��/��`��.�
E-Mail Address: Fax#: r •
. ,tra or Signature: '� �� 'Y�
y
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor& Materials)
Fire Alarm: $ � (�
Contact Ea /e Coun Assessors D�ce at 970-328-8640 or visit www,ea lecoun ,us for Parce/#
Parcel #
Job Name:C�'�}l C ��� Job Address: �`/� ��'��-- ��7'�'�+�-
— �/�-- �''�.
Legal Description Lot: Block: Filing: Subdivision:
ner Name•
r' �zz r�` S Add �:�x, �a-�c%F ���� Phone: I
Engineer�'�,����-� Address:
Phone:
Detailed Location of work: (i.e., floor, unit #, bidg. #)
Df''�`.'� 1/r.�9a t� ,�L.�G.� ,�'�7E�`z�vrc�
Detailed description of ork:,�� -
� ���'L'`f� 'S?iw�� ��- �-� Cr A'� �,�,.,r,�� �T r .���.hJ- .
�
Work Ciass: New ( ) Addition ( ) Remodel
O Repair O Retro-fit O Other ee�"t o G�j-�
Type of Bidg.: Single-family( ) Two-family( ) Muiti-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation units in this building:
Does a Fire Alarm Exist: Yes No ( ) Does a Fire Sprinkler System Exist: Yes No ( )
:�*:���*���,��*�*******,����*�*��**�*,�**�**FOR OFFICE US��� ���� D�pi���A� ��I
7'e9t'k9e *9t��Y�� ����� � *�c9ck�Y
�� .
�� Other Fees: - :� ' ` � °Date Receiv • ❑
S b Publpc Wa` =Permit Fee:- A ted B :
� Occupan Group:
. . . .
:,_,. �
F:�cdev�FORMS\PERMITS�Fire�alarm�erm_12-05-05.doc � ��'.��"
Page 1 of 5 :2/�5/2005
�
• A�P('���� Lb�.��lD� ��� i`�� o b
Pk�P�SE►� �JEvs
MAINTAIN EXIT FR i-}o2u hti�o �E
ONE VAIL PLAC LDct'�Tt�a
.
-� `�` REL ATE F.D.C. WITH DEMO TO
::�:``�� ED LOCATION
...:.. .....::.
....:.....:.:.::...
...... ..::.:.>
..:.... .::::.. .: ..,.: AP OV
�.,,, .. ..,... :,,,..1 � �
:�:•-�a""'�':::.. :•..::, ,....: ,
..:..
::.,w-� ' '
. •� , >
:t� / .:
., ,. ::1 .,: .::
.. .,... .
�,,,,.. :.,:::::.: .:�.. , ;.
,,.. .::..
, .. . r
. . ..
.:
,.,. :::::::::.: ::::
::::, ..
: .
. ... . .
.:::.
. .:: .
E,,�;�3.: .. ... � <:;«:� TENA�`�.
':GN�.;: ' ''?� �;
;��€� �, �!'ECAIL
.::: . ::.:.
� :;:<;>:«:<::»::::::;<::::>>:;; :::� •
�:: �
:3 �,, `:': .� : : • ' T.�
:a„� , ;:.:.. � .
.. •.�• 1
:: :
:::;.
:.::..: : TEN •
� , :>. � ::
; 4 > .,.:.. � >::: � TENANT :.< : �I"� AIL .
. .:.:..: ;
:.,. ;
::::..:.
> �. , .:..... �. � � RETAIL � :
:..:.<. .
r ; � � ::
�£Cv, : : . ` TENANT .
. ; � :.
,�� .: � � .. .>. ._>; .
:. . ......;....>
� REIAIL
<.
: .:..
...�.,...
1 • .::
:
,
. ; �
: • • �
. .� .
,
, .. �. .
.�
� ..: �.. �� �1 � � � ; >.,- °-��
, :..
;: ; , �,`;,. �
,::.. . ;:-.. >: A��Y 1 : TENANT :
,
:. r: ...:
� �� . `:.
: � � <: :,REfAIL
.
.::��`� � �
r �::�'� �
�WI N G ��}
... .
BY
::::�`:��;�:<;:,:>:<:::..:B
, ::1'; LO
. •
. ::::..:.. : ..::<:.:::..
,::;>;._. .
;...;:::::.;�>, >
.>..::... ::
..
' ` ':.
:
„ �� � - . .. M1f �.: TENANT
:.
s � ' ''° RETAIL
.. •
,
., .
., :. : � : : l
� :: }
�._::::£ ��s: .
� . � �
_
�c INT�L WING � � � EXIST1NG
. ,.
:
�: , . : i
� :
::
: 1
. .:.:, :: : �:
(ASS.UMED) :::::,: . Ex�T
5. .: ';.:.:� '� ' '' � � �: ADA ACCESSIBILIYY ti
, r : � � .�. ,� �': EXISTING RAMPS, �:CO
VEL :.�� ` .��. �"� 1�'� � T I N G `'� `� VAIL FRONT DOOR`:1h
�� �'���� ..� ,�� ``"�XIS �
- ``:: � E VAI L P LAC E `..:�.�...
�y:°;.::, :��E�st��� �QU �Tn�r� ON
. :
.: .
��::�.. , .: ..
;, ...:.... .. :
.� �
�;��r'.��iJ
; ; G
t
. .
,.a , ,:. , �>
<.
, . .
.
.
.
-%�,,:i�?>/ / ,:.. .... . ;._ ; :
NO CNANGE IN E
..l .w45yi ......... .
' � � �:.��i;:
... ............ '
�
' �, ` '�►��- � �
� .: � �' `-��,�
:
,��.�. ��;
.. . .,....,.
.
. :. . , . �
.. .
,
.
: .
_.. .. : . :..
�,.. .
. .
...w ..: .: . ��
..:. - ..
.:
.., . ;:. ,, : �. ; �� .
.., :- � . . ..... .
, :....:..... , ...�
, : .. . : .
..
.,,..,. . � ::. ...
. :
, : . . . . .....:� .
-� s���
. : . . .
... .......
. ' ; :_�::;:�r :�� � �
, �.� :
,� ,. .."�:. .. .. :i�� .. .■� �r: ,..,..
. .a�
: ::.,. ,.� � ��'— n�
� '_ �._� �.U�SR� ��
' � � • .4..
. :. ... �
, ,,;..:._,,;:
�,;s";��� P�Z�PC"
::•.. ' :
v,,. t
:; .� ;
,.f :; ::: ...
;.;:
�.;-'�.CONSTRUCTION �
�AINTAIN TEMP STAIR � �--
��,SHORiNG LINE SCAFFOLD DURI�tG / �- '�
:; �
,' � . ; CONSTRUCTIO
,, �r,. ,
: ,,.,:
,:,,:;'� > ;
�,, ,r,:; .; t
.'� i/"�//��i .. 'kS.C��.,' y.'.;' . •. ) ;
IJ. ` 1 � .
�S� * 3
�'r �� �1.+.'. .� k.. � .
.r;}' >
.. .:' ,,.11� ,�� '. ..�
!Ji' .
.. ..'.. !•i:' '?t. � , '>,:� . E i
�
APPLICA ON WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI �. �Z�
- Project #:
,� QO Building Perm�t#:
�
� Alarm �ermit �:
TnWNOFYAIL ` TOWN OF VAIL FIRE ALARM PERMIT APPLICATION
- Commercial & Residential Fire Alarm shop drawings are required at time of
75 S. Frontage Rd. ap�lication submittal and must include information listed on the
Vail, Colorado 81657 2" page of this form. Application will not be accepted without this
information.
CONTRACTOR INFORMATION
Fire Alarm Contr ctor: Town of Vail Reg. No.: Contact Person and Phone #'s:
�''"'��`' �`�/,-�yr,�
��zfze � f.��13�°� �i�.-✓ �c�`���°��-
E-Mail Address: Fax#: ���_ �'t�
,tra or Signature:
� .��!��
COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials)
Fire Alarm: $ Q �
Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www,ea lecoun ,us for Parce/#
Parcel #
Job Name:�/�� �� Job Address: ��`� ��'�� ���� ` —
��� �d�
Legal Description Lot: Block: Filing: -� Subdivision:
ner ame• Add ��t� Phone: I
� - f �� i�' S .'�x� c'Gy £��F�E
Engineer��„y��,�� Address: Phone:
Detailed Location of work: (i.e., floor, unit#, bldg. #)
D/'►�"� �,�4t c-- ,�'L4 C-r_ �'�T�'�z�cd��
Detailed description of ork:;�� �
i�f �c+�i'Z,,`.,d� �T z.��`°� � ,p'�� �=�� � � -�s(.E w`��F�..�� .�'�"�+ =
� -
Work Class: New( ) Addition ( ) Remodel ( ) Repair( ) Retro-fit( ) Others��t�C`Lc�'�
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation units in this building:
Does a Fire Alarm Exist: Yes No ( ) Does a Fire Sprinkler System Exist: Yes � No ( )
***�r�*�*�**�***�****��*�r��*��*�r������*�FOR OFFICE USE ONLY�r**�*******�*��r**�*��r*��**��**��*����
Z� Other fees: ;: Date Received; . .
/ °P blic Wa :Permit Fee. ;� Acce ted;B : '
�b u
Occupancy`Group• � �
F:\cdev\FORMS\PERMITS\Fire\alarm�erm_12-05-05.doc Page 1 of 5 12/05/2005
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT Permit #: E06-0125
�� G� -cz_> t�S�
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 07/28/2006
Parcel No...: 210108278002 Issued . . . 08/10/2006
Project No : t���-�� -C�o:�.�� Expires . .: 02/06/2007
OWNER LODGE PROPERTIES INC 07/28/2006
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 07/28/2006 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
CONTRACTOR ENCORE ELECTRIC 07/28/2006 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
Desciption: VAILS FRONT DOOR-TEMPORARY POWER -��c� �
Valuation: $14,500.00 Square feet: � 0
*************************�**********************x**�*************** FEE SUMMARY *�****************�***�******************�******************
Electrical---------> $327.75 Total Calculated Fees--> $330.75
DRB Fee---------> $0.00 Additional Fees----------> $0.00
Investigation----> $o.00 Total Permit Fee--------> $330.�5
Will Call---------> $3.00 Payments------------------> $330.75
TOTAL FEES--> $330.75 BALANCE DUE--------> $0.00
****�****************************�********************************************************************************�******************************
Approvals:
Item: 06000 ELECTRICAL DEPAR.TMENT
07/28/2006 shahn Action: AP
Item: 05600 FIRE DEPARTMENT
*�**�**************�***********+*************+****************************************************�*�*********�**********************************
CONDITIONS OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
*******************************�*****************************�***�**�*************�**�***********************************************************
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
C
SIG U OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
***********�**+************�*�*******+*****************************************�************
TOWN OF VAIL, COLORADO Statement
****************************************************************************'****************
Statement Number: R060001196 Amount: $330.75 08/10/200610:44 AM
Payment Method: Check Init: DDG
Notation: Encore
Electric 1504
-----------------------------------------------------------------------------
Permit No: E06-0125 Type: ELECTRICAL PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $330.75
This Payment: $330.75 Total ALL Pmts: $330.75
Balance: $0.00
************************************************************�*******************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 327.75
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSI ��- ��S
Project #:
� �� Building Permit #:
....
�� � � ` Electrical Permit #:� �,_,(S(
, �
�"�'��`�� �70-47�-214� (Inspections)
75 S.Frontage Rd.
Vail,Colorado 81657
TOWN OF VAIL ELECTRICAL PERMIT APPLICATION
CONTRACTOR INFORMATION
Electrical Contractor: Town of Vail Re�No.: Contact Person and Phone #'s:
ca't� ����t`�z-��- �� �� � /�w-! C�.�r�-rz�-. `17� ��Y lr-lYi3
E-Mail Address: Fax#: G17U� y�Q- �"L�
or Sign�ature:�
,�� �,
COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials)
AMOUNT OF SQ FT IN STRUCTURE:° � ,� ;;�/�'L ELECTRICAL VALUATION: $ d�
Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www,ea le-coun ,com for Parce/#
Parcel # Z CQC p g�`7�3�j�-
Job Name:��� t�''�°�""'� �����- Job Address ���� ���r��-- ��`�"��"�
;l:A�c�- �O
Legal Description Lot: Block: Filing: Subdivision:
Owne s Na • �.� �.� Addre e vF �� � Phone:
Enginee�� C�'.����f 5 A �� '�� �— C,f;) � Phone:
Detailed description o�work: �,���� ��.c�c`�-
Work Class: New( ) Addition ( ) Remodel ( ) Repair( ) Temp Power ) Other( )
Work Type: Interior( ) Exterior yC,l Both ( ) Does an EHU exist at this location: Yes ( ) No �
Type of Bldg.: Single-family( ) Duplex( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( ) �
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
Is this ermit for a hot tub: Yes No
Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
�*�*���*��*��� �**�*�**����*�**�*****FOR OFFICE USE ONLY*�*�****�*�***������r*��r�r�r*�r**��r*�r****
� �
b .
�3 �:Ot�rer Fees. � �Date Rece��ed: �
=�'DRB Pees'. . . Acce ted:B :.
Planner Si n-off.
�
F:\cdev\FORMS\PERMIT'S\Building\electical�ermit_11-23-2005.DOC Page 1 of 2 li/23/2005
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
ELECTRICAL PERMIT Permit #: E06-0189
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 09/27/2006
Parcel No...: 210108278002 Issued . . . 10/30/2006
Project No : -��1�-�� �a�� Expires . .: 04/28/2007
OWNER LODGE PROPERTIES INC 09/27/2006
PO BOX 7
VAIL
CO 81658
APPLICANT ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
CONTRACTOR ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277
PO BOX 8849
AVON
CO 81620
License: 331-E
Desciption: ELECTRICAL FOR CONSTRUCTION OF A 3 STORY UNDERGROUND
PARKING STRUCTURE WITH LOADING DOCK AND ACCESS TUNNEL
CAST-IN-PLACE. ALL SITE WORK IMPROVEMNETS AND
LANDSCAPING.
BUILDING "A"
Valuation: $708,869.00 Square feet: 0
**�:�**********************+******�********************************* FEE SUMMARY ************************************************�***********
Electrical---------> $14,457.50 Total Calculated Fees--> $14,460.50
DRB Fee---------> $o.0 0 Additional Fees----------> $o.o 0
Investigation----> $0.0 0 Total Pernttt Fee--------> $14,4 6 0.5 0
Will Call---------> $3.00 Payments------------------> $14,460.50
TOTAL FEES--> $14,460.50 BALANCE DUE--------> $0.00
�******************�**********************�**********�*****************************************�:*************************************************
Approvals:
Item: 06000 ELECTRICAL DEPARTMENT
10/05/2006 mroyer Action: AP
Item: 05600 FIRE DEPARTMENT
**�**********�*******�*****�******�*****�************************�******************�***�*�***�**********�*��************************************
CONDITIONS OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
*�************�**************************************�*****�****�***********************************�*************************�********�*******�*
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes an her ordinances of the own applicable thereto.
!/�/� J
******��*************+***+�**�**�************************�*�******************+**********���
TOWN OF VAIL, COLORADO Statement
****�:*******************************�x�x**************��:�:****************:�++****�x**********�x�x*
Statement Number: R060001844 Amount: $14,460.5010/31/200605:12 PM
Payment Method: Check Init: DDG
Notation: Encore
Electric 20506
-----------------------------------------------------------------------------
Permit No: E06-0189 Type: ELECTRICAL PERMIT
Parcel No: 2101-082-7800-2
Site Address: ].74 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $14,460.50
This Payment: $14,460.50 Total ALL Pmts: $14,460.50
Balance: $0.00
*+*�*:�***********+�x******************�*******�*:x***********�********************�*�:x�*******
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
EP 00100003111100 ELECTRICAL PERMIT FEES 14,457.50
WC 00100003112800 WILL CALL INSPECTION FEE 3 .00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE����� ���5
Project #:
Building Permit #: � b� �
��G— Q 1 � � Electrical Permit #: C ' `O� gs
� 970-479-2149 (Inspections)
TOWNOFYAIL TOWN OF VAIL ELECTRICAL PERMIT APPLICATION
75 S. Frontage Rd. �
Vail, Colorado 81657 � � / �
I � � �Q
CONTRACTOR INFORMATION
Electrical Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:
�1�c�'r�e �l � i c l ��i -� �0,.,� ,� �rnd
E-Mail Address: << , _Fax#: �-�� - c��q _ a 2�, =
Contractor Signature: �
�
COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials)
AMOUNT OF SQ FT IN ST'RUCTURE: � �` � j 5 ELECTRICAL VALUATION: $ ��;' ��`� �'(�C-(
Contact Ea /e Coun Assessors O�ce at 970-328-8640 or visit www,ea le-coun ,com for Parce/#
Parcel # 2 ( b `� � 1�(�a "-
Job Name: vU � �5 �U�� ��� 7ob Address: �1� �c(U1((-� �'....LQ�(,� �''•
v t
Legal Description Lot: Block: Filing: Subdivision:
Owners Name:L�G� � �j.;� � .Address: � Phone: �7 � _ ��>��
Engineer:A�S C 5� , �t� Address: ��Z3 .�,U � Phone: �U3_ �z� _ � Zu�
Detailed description of work: ��,,.�L��� �,� � '� 5. � V�,-� . V��
�;u.�c `��-rv���-�, w;�-, I c�u�.l�r�� d v L �/-;d �L�sS
Work Class: New ( Addition ( ) Remodel ( ) Repair( ) Temp Power( ) Other( )
Work Type: Interior( ) Exterior( ) Both � Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family O Duplex O Multi-family O Commercial Restaurant O Other O
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
Is this ermit for a hot tub: Yes No
Does a Fire Alarm Exist: Yes ( ) No Does a Fire Sprinkler System Exist: Yes ( ) No
�***��**��*�����***********���*******�*FOR OFFICE USE ONLY*****���*��*�****��*�***������**�**�*
� Other Fees: Date Received:
� ., DRB Fees: ACCe ted B :
� �`� Planner Si n�-off: �
�
, ,
F:\cdev�BUILD�G\APPL[CATIONS\ELECPERM2005.DOC 07/O6/2005
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
MECHANICAL PERMIT Permit #: M06-0219
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 08/18/2006
Parcel No...: 210108278002 Issued . . . 08/22/2006
Legal Description: Expires . .: 02/18/2007
Project No :
OWNER LODGE PROPERTIES INC 08/18/2006
PO BOX 7
VAIL
CO 81658
APPLICANT HEATING & PLUMBING ENGINEERS08/18/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLOR.ADO 80204
License: 347-M
CONTR.ACTOR HEATING & PLUMBING ENGINEERS08/18/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 347-M
Desciption: MECHANICAL WORK FOR PARKING GARAGE TO INCLUDE 16 FANS, 5
HEATERS, 4 SOUND ATTCAVITORS AND ELECTRIC HEAT
Valuation: $190,376.00
Fireplace Information: Restricted: #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0
******************************************************************** FEE SUMMARY ******�***********************************************�*****
Mechanical---> $3,82 0.o o Restuarant Plan Review--> $o.o o Total Calculated Fees---> $4,��8.0 0
Plan Check---> $9 5 5.0 0 TOTAL FEES--------------> $4,��s.o o Addirional Fees-----------> $o.o 0
Investigation-> $o.oo Total Pernut Fee----------> $4,778.00
Will Call-----> $3.0o Payments-------------------> $4,��8.00
BALANCE DUE---------> $0.00
**************************************************�****************************************�*****************************************************
Item: 05100 BUILDING DEPARTMENT
08/18/2006 JS Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Cond: 22
(BLDG. ) : COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION
304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL.
Cond: 23
(BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND
CHAPTER 10 OF THE 2003 IMC.
Cond: 25
(BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC.
Cond: 29
(BLDG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003
IMC AND CHAPTER 3 OF THE 2003 IFGC. .
Cond: 31
***�**�*************�****�****�*�**********************************************�*�*+********
TOWN OF VAIL, COLORADO Statement
*****�x***********�***********�*********************************�x**+*************************
Statement Number: R060001277 Amount: $18.00 08/22/200602:56 PM
Payment Method: Check Init: DDG �,���k—
Notation: i�t��&
Plumbing 2603
-----------------------------------------------------------------------------
Permit No: M06-0219 Type: MECHANICAL PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $4,778.00
This Payment: $18.00 Total ALL Pmts: $4,778.00
Balance: $0.00
:�****************************�:************************************�*************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
MP 00100003111100 MECHANICAL PERMIT FEES 15.00
WC 00100003112800 WILL CALL INSPECTION FEE 3.00
-----------------------------------------------------------------------------
(BLDG. ) : BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS
LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING.
Cond: 32
(BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR
TO AN INSPECTION REQUEST.
Cond: 30
(BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED
MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 .6.
*******************�*�**�**�*********************************************�***************************************************************�*******
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
..�,,..�e �f�. �
SIGNATU WNER O CONTRACTOR FOR HIMSELF AND OWNEF
�
` � APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNE� (aL��'Z$
TOV Project #: V '�C.> �°
Building Permit #: o ^ !$
- .� ��� � � Mechanical Permit #: �/
��Q��1� ' 970-479-2149(Inspecti ns) (
TOWN OF VAIL MECHANICAL PERMIT APPLICATION
75 S. Frontage Rd. Permit will not be accepted without the following:
Vail, Colorado 81657
Provide Mechanical Room Layout drawn to scale to inctude:
❑ Mechanical Room Dimensions
❑ Combustion Air Duct Size and Location
❑ Flue,Vent and Gas Line Size and Location
❑ Heat Loss Calcs.
o Equipment Cut/Spec Sheets
CONTRACTOR INFORMATION
Mechanical Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:
' lk „ � s 3`7�7--M �re 5 Zv-Z� -z/h'�
E-Mail ddress: f�� � ���� �� . Fax#:
Z� 'Z �o
Contracto igna ure:
, ��11 � zc� —`��o � �3�7.
COMPLETE VALUATION FOR MECHANICAL PERMIT Labor & Materials
MECHANICAL: $ I��/ ��C-� ��� �� X 1,ZS _ ;�L ��O
Contact Ea /e Coun Assessors O�ce at 970 328-8640 or visit www,ea /e-coun ,com for Parce/#
Parcel #
Job Name: vA�r7s Fmn� �R $k�Ice�n ,�} � Ga,,� G�,,�,�K ��R
�,r,k�n � ]ob Address: 7 Y
�1a �o « Doc.K. U�,�. co 8/6.Y' ,
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: ��• eSG+'?�,5 Address: Ro, /jox QS""T Phone
a o Lo Z '�`°"�"�... ���....��'�-.��.
Engineer: Add�ss:�53� !!s"'� Sf saik.
S � Phone:3d 3-�623 -6 Znb
Detailed description of work: �n��.rcqz, �vo,e� � �,�.r,�„5 6,ti,,,�,�e 'tv �nc.L��,¢ �L
�x S , S nvFr�! r?W ��,�-re rs� y sorc�d ,p�,�u�t-YarS �-e'/c c. 1{+4-T.
Work Class: New(p�) Addition ( ) Alteration ( ) Repair( ) Other( )
Boiler Location: Interior( ) E�erior( ) Other(�() Does an EHU exist at this location: Yes( ) No (�)
Type of Bldg: Single-family( ) Duplex( ) Multi-family( ) Commercial (J(� Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No T e of Fire laces Existin : Gas A liances Gas Lo s Wood Pellet Wood Burnin
No/Type of Fireplaces Proposed: Gas Appliances( ) Gas Logs( ) Wood/Pellet( ) Wood Burning (NOT ALLOWED)
Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No ( )
************************FOR OFFICE USE ONLY*****************************
Other Fees: Date Received:
Accepted By:
F:\cdev\FORMS\Permits\Building\mechanical_permit_l1-2�-2005.DOC 11/23/2005
� y �
l �
************************************�*******************************************************
TOWN OF VAIL, COLORADO Statement
*************************+******************************************************************
Statement Number: R060001238 Amount: $4,760.00 08/18/200608:00 AM
Payment Method: Check Init: JS
Notation: 94023/HEATING
AND PLUMBING ENGINEERS
-----------------------------------------------------------------------------
Permit No: M06-0219 Type: MECHANICAL PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A�
Total Fees: $4,778.00
This Payment: $4,760.00 Total ALL Pmts: $4,760.00
Balance: $18.00
*******�x************************�********************************************************+**
ACCOUNT ITEM LIST: �
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
MP 00100003111100 MECHANICAL PERMIT FEES 3,805.00
PF 00100003112300 PLAN CHECK FEES 955.00
-----------------------------------------------------------------------------
11��
��.,
�� II ��
i�
AGENCY
January 23, 2007
Charlie Davis
Chief Building Official, Town of Vail
75 South Frontage Road
Vail, CO 81657
RE: PROJECT: Front Door Plumbing Revision
PLAN REVIEW: P06-0076
ADDRESS: 151 Vail Lane
Dear Mr. Davis:
Colorado Inspection Agency has completed a review of the following documents:
1. Plans:
■ 4— Plumbing Sheets
These documents were reviewed only for their conformance to the provisions of the 2003
International Plumbing Code. Colorado Inspection Agency finds the documents submitted
to be complete for construction and ready for issuance.
One hour of plan review fee is due. $60.00 total.
Sincere ,
,
-,--...
�
John Plano
Plans Examiner
Colorado Inspection Agency
Colorado Inspection Agency p:970.328.1790
1286 Chambers Avenue f:970328.1791
Eagle,CO 81631
�Z 3F"��y�., y` . ; '�,f : ,�:
� :"ffi�s, i .z+'i � `�
_ m f.a' � ��Y o4 �s'�` �. �'. . . %Pe�'.. ... hP
Colorado Inspection Agency
Eagle Office
°��_
12�ffi C:.t��rnk�t;rs:�1v�r�ue> �1C71 Pic�r�s �xc�rnrr�t;�: --+v`"'N L�t-��
G�ac�le, :c;ic�rac�c�81�a;�l EsiailcJir�g :)�ficicyl: Matthew Royer
C�ffic� i'i?c�c�e: 970-328-1790
.---�
P!,rrr�il #: �' �� -� L`X.��� l��le;rn��f �'cf. #: �C�(
Prc.7j�c:t l�ic�rr��. �2ur—T �cs"O�_ �?evisi�.�r� nc.�rr��k��r: �'�
C�eseription: `�L.-_��'— CZ.�.�"T�' G�-(Z�f�s�- / S�D a i�.- r o.��-f`�2-���'i�
�__.__ _
. 2LV�I ��L� U
��,��0-7
APPLICATION WILL NOT BE ACCEPTCD IF INCOMPLETE OR UNSIGNED (e-�� �o
r Buildin�Permit#
�M. �( �. •���� b 9Z,�t�=47J-�'��4J(t��pecti.pn�)
�J
������ � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
U" �O — � �el-r CG _ �
ATTENTION: E, ,CHARLIE,GREG,CHRIS
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea /e Count Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parc���
a l o G&���,
Job Name: U�; �� ��t Job Address: ��� U�, � �n�
YJoo�' `
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: U��� ��� Address: Phone:
ArchitecUDesigner: y2 /y o Address: Phone:
Engineer: �S Address: Phone: �
REASON FOR REVISIONS: I�ra�.�.�� s�-�� /�;t -ta su��+�.r� etj�-h,�--
Work Class: New�Q Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
NoIT e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes ( ) No( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( )
FOR OFFICE USE ONLY
O�her.Fees: � Occupancy Group; _- _ � Acc ' '; �.k '
';TYpe of Construction: - :'-. . .-,'=;. : Date Received: :;
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT Permit #: P06-0076
�-j�t�� _ o��5
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 08/Ol/2006
Parcel No...: 210108278002 Issued . . . Ol/26/2007
Legal Description: n Expires . .: O1/30/2007
Project No : `��~�U�' � u���
OWNER LODGE PROPERTIES INC 08/O1/2006
PO BOX 7
VAIL
CO 81658
APPLICANT HEATING & PLUMBING ENGINEERS08/Ol/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 353-P
CONTRACTOR HEATING & PLUMBING ENGINEERS08/01/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 353-P
Desciption: PLUMBING WORK FOR NEW PARKING GARAGE INCLUDING PIPING, SUMP
PUMPS, SEWAGE EJECTORS AND DRAINS
Valuation: $271,536.00
Fireplace Information: Restricted: ?? #of Gas Appliances: ?? k of Gas Logs: ?? ll of Wood Pallet: ??
��*************************�***************************************** FEE SUMMARY
********+********************�******�***********************
Plumbing---> $4,08 0.0 0 Restuarant Plan Review--> $o.0 o Total Calculated Fees---> $5,10 3.0 0
Plan Check---> $1,02 0.0 o TOTAL FEES--------------> $5,103.o o Additional Fees-----------> $o.o 0
Investigation-> $o.o o Total Permit Fee----------> $5,10 3.0 0
Will Call-----> $3.00 Paymen[s------------------> $5,103.00
BALANCE DUE---------> $0.00
***�********�*****************************�***************************�*****************************�***�*��:*******************�**�**�****�******
Item: 05100 BUILDING DEPARTMENT
08/Ol/2006 JS Action: AP
Ol/23/2007 jplano Action: AP REVISED PAGES P001, P101, P103 AND P104
APPROVED, ONE
HOUR OF PLAN REVIEW DUE, $60.00
CONDITION OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
Entry: O1/23/2007 By: jplano Action: AP REVISED PAGES P001, P101, P103 AND
P104
APPROVED, ONE HOUR OF PLAN REVIEW DUE, $60.00
*********�*******�*�*********************�**************************************************************�***�*************�*********�******�:*�:***
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM. -
SIGNATUR OF NER OR CONTRACTOR FOR HIMSELF AND OWNEF
�\
(:'�vG�� , ��L�
►���?`�-� �
APPLICATION WILL NOT BE ACCEPTCD IF INCOMPLETE OR UNSIGNED (e_�� �o
�Y � ✓�� � Building Permit#:
��
� � 970-479 2149(Inspections)
�������� � REVISION TO TOWN OF VAIL BUILDING PERMIT
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approv�d plans. No further inspections
will be preformed until the revisions are approved. ***
CONTRACTOR INFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
Glcr Co v - C� (�ee�-� �� _ �
ATTENTION: �E, ,CHARLIE,GREG,CHRIS
Contractor Signature:
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials
REVISED AMOUNT: $ �� ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $
For Parcel# Contact Ea le Counf Assessors Office at 970-328-8640 or visit www.ea le-count .com
Parcel#
ollola�a.2r�
Job Name: — Job Address:
�Vc.; ►.� r�t YJoor- I s� v�„ 1 L-o.,.�.
Legal Description Lot: Block: Filing: Subdivision: �
Owners Name: UG�� ���� Address: Phone: �
Architect/Designer: y2 /L�a Address: Phone:
Engineer: �S Address: Phone:
REASON FOR REVISIONS: /�ra��� s�-�� ��;� � sG���.f-� e�j��,.-
Work Class: New� Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior( ) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A ►iances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Atarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No( )
FOR OFFICE USE ONLY
Oth�r Pees: �ccupancy Group: '�� Acc ' ;'
Type of Construction: ` Date Received: '
F:lcdev\FORMS1Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 12/8/2005
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT Permit #: P06-0076
�U� _._;<��,i �-
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 08/Ol/2006
Parcel No...: 210108278002 Issued . . . 08/03/20.06
Legal Description: —�.7�:��� __L�C;;` � Expires . .: O1/30/2007
Project No : •
OWNER LODGE PROPERTIES INC OS/O1/2006
PO BOX 7 ,
VAIL
CO 81658
APPLICANT HEATING & PLUMBING ENGINEERS08/Ol/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLOR.ADO 80204
License: 353-P
CONTRACTOR HEATING & PLUMBING ENGINEERS08/O1/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 353-P
Desciption: PLUMBING WORK FOR NEW PARHING GARAGE INCLUDING PIPING, SUMP
PUMPS, SEWAGE EJECTORS AND DRAINS
Valuation: $271,536.00 �
Fireplace Information: Restricted: ?? #of Gas Appliances: ?? H of Gas Logs: ?? #of Wood Pallet: ??
**********************��*�:*****************************************�* FEE SUMMARY
*****************************************�******************
Plumbing---> $4,080.00 Restuarant Plan Review--> $0.00 Total Calculated Fees---> $5,103.00
Plan Check---> $1,020.00 TOTALFEES--------------> $5,103.00 Additional Fees-----------> $0.00
Investigation-> $0.0o Total Pernut Fee----------> $5,103.00
Will Call-----> $3.00 Payments-------------------> $5,103.00
BALANCE DUE---------> $0.00
�*�***�***************�*************************�**�**********************************�*�*******�*�***********m****�****************�*******�*�**
Item: 05100 BUILDING DEPARTMENT
08/Ol/2006 JS Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
************************�*****�************************************�*******************�*�**************�****************��*****�:***************+
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM.
SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF
m_,—�.�;.
�`�; � � �--��;L a� Z�!G�tv
� �d
i '_.� �
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED �� �� �✓� � �
Building Permit# �
#. 9TQ-479 2149(irispect�ons)
����Y� � REVISION TO TOWN OF VAIL BUILDING PERMIT `�
Separate Permits are required for electrical, plumbing, mechanical, etc.!
75 S. Frontage Rd.
Vail, Colorado 81657
***All Revision submittals must include the Field Set of approved plans. No further inspections
will be preformed until the revisions are approved. ***
�<t�-`�- '{' 1''��tl � - CONTRA�6�91VFORMATION
General Contractor: Town of Vail Reg. No.: Contact and Phone#'s:
_ !�1-A- �o�.
ATTENTION: JQE,JR,CAARLIE,GREG,CHRIS
Contractor Signat .
COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials
REVISED AMOUNT: $ ELECTRICAL: $ OTHER: $
PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ _
For Parcel# Contact Ea le Coun Assessors Office at 970-328-8640 or visif www.ea le-count .com
Parcet#
._._.. .
�.l 0l o Fs�.2���-�.
Job Name: Job Address �5( Uo•;( L.n
Vw; �
Legal Description Lot: Block: Filing: —� Subdivision:
Owners Name: Address: 13�' �'-��K Phone: `c� s�+s Z3co
u � c.
ArchitecUDesigner: Address: I`2� �g'"�5 4+��cc� Phone: 3D1 �+'-��
�Zi �
Engineer: Address: Phone:
REASON FOR REVISIONS: 1"'0 �-;�e. 11•e- S�w{� !_.octg�.TowQr �o.rt.g� �(�%�a5.. ►�--t-� �•�
t3ld �-
Work Class: New� Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( )
Work Type: Interior(x) Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( )
Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial(X) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin
No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED
Does a Fire Alarm Exist: Yes O No O Does a Fire Sprinkler��errr�xist;�.-._�X�_(___,�,__, No O
-, �.
;_
FOR OFFICE USE ONLY ,�
� ;.
�
=0ther Fees: . , Occu anc' Grou : cce B .
Type of Construction n;} Date,Received: �;, ., :: ; ' M
� - A � ' ;
F:\cdev\FORMS\Permits\Building\building_revision_11-23-2005.doc Page 1 of 2 �� ` 12/8��005 :
4240 ,
ARCHITECT'S SUPPLEMENTAL
INSTRUCTION No. A-OOt�. VAIL'S FRONTDOOR
ro: Doug Thompson/Hyder Construction, Inc. PROJECT No: 2Q693.08
543 Santa Fe Drive issuF�: 09.07.06
Denver,CO 80204 FROM: genjamin Gray
303-825-1313 ' , 303-292-3388
The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract
Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instnactions
indicates your acknowledgement t�iat there will be no change in the Contract Sum or Contract Time.
ArchitecYs Supplemental Instruction Title: Building A-SLT Drainage Connections
Reason for Change:
To tie the South Lodge Tower downspouts to the Vail Pront Door Building A storm sewer system and to tie the South Lodge Tower
garage drains to the Vail Front Door Building A sandloil interceptor.
Descripfion of Instructions:
See attached plumbing drawings from.4BS.
Construction coordination with the plans for the expansion of the South Lodge Tower necessitates the installation of a storm
drainage line from the west side of the proposed elevator tower to the Vail Road storm manhole P32. Roof drainage downspout#R4
and area/planter drains will need to be routed from a 4"interior storm line within the laading dock. A cleanout is to be provided at
fhat point in which the line penetrates the exterior wall(See South Lodge Tower Plumbing Plans}.
The attached plans show the routing and invert elevations for the proposed 6",SDR35 PVC storm drain pipe. This plan is a portion
of the Vail's Front Door Site/Civil Construction Plans Sheet C14.A. '
Pricing savings and/or additions are to be provided to the Owner in accordance with the submittal of this AST.
Attachments and Enclosures:
AB S plumbing sheets: P 102,P 104,P 105,and P 107,ail dated 9/Q6/06.
AEI Civil Sketch: South-J_.odge-Tower-Downspout-Area-Drains dated 9/OS/06,and Letter dated 9/07/06.
By. Copy To: ASI File
Rick Caudel/VRDC
Received By: Alex Valdez/ABS
Bob Herbst/AEI
42�40 ARCHlTECTURE INC
1621 Eighteenth Street
Suite 200
Denver,Colorado 80202 The information contained in this message is priNleged and confldential intended orYy for Ihe use of ihe individual(sy or entity(ies)named
t 303.292,3388 f 303.292.3113 above. It the reader of tFrs message is nOt the intended recipient,you ara hereby notified that any disseminetion,dislribution,or copying of
www,424parchitecture.com this communication is striqly probibited. If you have received this communicaGon in error,please notify 42/40 Architecture,Inc.immediately.
S—�
� SiaR
� n50t C
Q.5_"—__' '—'___"—__'
BN�ElF�t
RQOM
0 �EC
,_
a��
'ORnGE
r,�
�-------- --�: -- 5--
I �IE�bIV35Y I I I � I 9 � � 9� �
I �b'SLffVE l � r4.
50 •b16352'� I — _ _o� ' �4. 1 9.F5)
I � �
�
b�3'-d
� — I�IE�DIS7p'
-- '—- ' IE�DIS] I i , 5 I IEi 8154 siss
4 '_' I = �
] � , � ------ --- -- --- - � -,-- --- - I� � �I-- —
sisa-o � —_ 5 I b B S llvo2_' __�_ COUF_ ,�
� \� I � i I iP il I ��A I - �I i6 1
, I
� � � I
I � � � I
,� � i I
� � I
1B I M����I ]0 3i �] �� N II I I I COUI
\ ais3. .I \ I \ I �5 i )E I 4�) 79 �y W a�
/ � � I I �
!—"_ ol _ _\ I
__ \
\ —__ ___
28'-3'I \ \ _—_ ___ '__ ___ __" ___ __' ___ __
\ �
�� � I a wro[cnixr[o
� \ �rNE Of iUNNEI i , i L�MES(M) I
� 53_0.� I1 � � <B�
CON/rtEtE CURB � / I I �
nNO�wax I � ��� 4 i I I
I �e � � I
iE I i9 � 20
ae.�.,ai s� /I!I '
—_ _ Bi56'-fi / I I
i; 71 ' _ IJ "� 3�I
.} µ I� �� j� � I
�5 66 a8
I49 50 I Sil
I I I
IE8166.4'
'______ '__ ___ _b ECa/5 _—�haiLLL tArOUi� ____ __�_
� I GpR GCH g1v I ZI
�_��� {•�J -- IE�6150.1 �CwiP�EVEL GnMGC�. �v Putq' S?nLES In I I UI O
. ouv J�— __��i_--_ I
� \ I 4. DMix 4� T— _� �� _ 4aD-� � �__
� SLOPE AT I/B'PB2 F(XjT—
4 I �� � I � IEi01 6' 4'� T ,.T 3 50�_
y�p� � � I I av Ru.v � 4.�
IE��l5f3' � � I ��\ ai5� I 4 ��DI653' I
� �
�� I I � � ' IE�BIM9 i� IE�HI525' � I 5 Wo\ e s-o
( N-�'—____'_______'__ _ " _—' __' _' '_ \ I �MES(m)
IEHIS
�J ��_ ___ '_ 5 I�fECys
� �r -- , I - -- -- --- -i — — -- --- - --
�
I55 56 5) I \\58\� �\g 6p 61 I C61P fil II 6ai COMD. •�
65 66 61 fifl I E4 )0
I I�° ,ou���nE � �II
� I ur�or nxx¢I
�BO�f I�4' i
I I I
I I I II I I
�
couv
�_—_—_—_—_—_—_—_—_�_—_—_—_—_—;� —_—'__ _" I _'A_—19 —80\\ � Bi Bi I ESI A� B5 CBMP. I
�� I 'I _— _ _—_ _�_ _—_ __' ___ _-8� _-990 —89
blsa'.p I
�---- -------------�---------------I----- I �:a�\6, I/ / I I ji
i I . . ;. ,. ... . I ,
I � �
I I I
25 Zq �
23
I I ,
� �
I I
ZZ 21.�
OI !�'�82 TO 51ff7 PI04 FLR CONfIIUATIGI
LEGEND O 4•�",�,��++�+�
!��%iF'%%% O 4'S0 H15TE UP TO,VEA ORAM ABOVE.
\ Q 4'STORM DOHI FRqi qgpyp(p103)TO�J.OW FLLVR
BUIIDI �-P�R�IN6 5F${�.BgZ pppy�pE CLEANpn AT 18'AF.F.
E%MRE� OS 4'S0 YL��TE WYN ON COU1tM TO BBDW RQ�R
RE�DiPl0\1 PROJIDE CZEANp/i AT 18'AFF. �
BUILDIN6 D'� �-5yg�p�p� b 10'STORM�OYN FRpM LEyg,qgp��.
�����
OO +'sr aorra�oF wn�sw,Fr.
BQ r�ar Twce�vo u�,u�ai�s Pex iscco srrsiFicnnor�
O a•so ws��on sanH�o�e�ra,at Re�x.o
s�T r�w wre carmruAnmt
CONEGT 4'50 TO TRHJLX DRhIN ABPiE.
G.�
„
¢ Q�
Bi56-a I "
_—______-- _—_�,�e�l 141� u..i
IE,816585' ' a-n pF�iH _�� I �
� ` �E,e�,���T-
4'
W
z I
i = IU
—__ _—___—_ _—_ "—_ _—_ �
i—
� � �
Ii >1 ]) I ]a 15 )6 I i�
I I I
I � �
90 91 93 I 9J ga I I
__________ ___ ___ _ 95_ _ I_
i �5a-� � ° � I
, ' � � ' y >
II i Bi51'-1 J/�' ��Bi55'-ii 3/a' �
' I uNE D ROqt oBOVE�'� I
I BisO'-i i/a" /
f��I O S' �? �IE815B.II �4�� Bi59'-t0 i/3'I Bi5)'1ZJ%� � T 4T�� BiSfi-
I I� � II PEi.Wk1 BROW T
SEE:SiRUCi I ✓ .1 \J '
II� I �I ei60'-0 1�Z' lV� I
I Bi5)'-)!/� �
� �� � i ��m
� O I / B'�Sl'-
I ��qT�y,� �Q/Q J
�U£,
I I � �a-sa—s i,'sro��� /�� j c
� �\ , i � �
� ,� ���'��� �
I//--LONLAEiE CUxB� � -\\� � e1�� I
/ &CU11ER ttP. � � � `\ \ `\
�� I8�6i''� PE SiRUti.
/ OR Rpp(—�\�\\
/ \\ � �Z
i � ;, �,5._2.
// I/ \`� � I
/ �
�� eia�-s va \
/
i Cuu w�.l
i 6ELOw
I I
I n
I I I I �e;
�9.8 7 9
.�..�
S�P 2 6 2006
�
O
Q
� �
1'-� �
o z
� A
V 1 �
�
�
011NpiN6YpOP01
VAIL RESORTS
DEVELOPMENT
COMPANY
svox,cowwno
42�40
ARCHfTECTURE
'm':a�°�
��
��
�����
°�J °DDP
� 9 a oa
•�c��.a�
BUILDING A
PARTIAL LOYPE
GARAGE PLAN
iPEST
P10�
ON
�
a
s
a
�
i
u
�
<
a
4
�
y
mp
b
m
8
7
u
�
�
�
�—
F2E:PI04
� � � 4 �3 u��IXn �B . 3Q � � 3 �4, . .— — —�— — —�— . 6���� I� — — — — � — — _ RrE:PI04
'- 3 .�j ' Cuua 5 �U I I
. , � . � 3 — _ _ � _
i ^ �
. .'; ` — 0 �NM�B'�fi J' Fi' II � ��OG E . � �
\ � Si � 4
'____'_ b I ` ..-- I
4 - � �I
I __'-___ ' II I b e a>' Bi6�'-i i z' Q 6 _ � ' IE8161.75 --
IS ' p I � b• I 11 RtAIH i II ��`. �i.94' - -� - -—r-_
\
'-> i�o A51 � � I � �
A51 A51 4 A51 I� \ / � �
I � �AiP10] I
�-- S BELOW. 9i64-9 4 I �� I' (7 � � ��� -" � /� I � I I
HOwN D.�SrFD ��-p O
I �J �
�
4 I
4 I II 9
DiiN /__- BI66 ♦ � I � � \ I � I II I � I 1�
/ C ____ _ MiD-�EVE�vqR iNG � I , � I
/ nz+o - -—-— —- _r�� �
� � —n �
I � i --- lT�-—-i-— �
'63� mxcaerz aae � i
exo waK � 4 �b' ct.etv. �
CONCP CLWB bi66.-�• I I � I�. II 4• AT OFBEAMII ' � I O �
(�') W'-6'x]'-6 uEC4 � I I �\ � 3� , I I I �"'�
— � _ _ _ _ �oPE���wE �� � , o -�- - i Q—i A
_ _ _ _ � � D
- I' I r
� � Btfi6'-.. —-—�EG/5 -—-—- —-__ _ - EU/S II �&P201 'T
�'j O I � _—_— — _—_ ___ n ____1` ' , ~
I � I "'a"DEEP 6EAM — +� `_, �'1
Bt69'-5 I/s" Bt�B. > i/Z• I � � S 8�68'-a" �I r^ /��'y��
/,`� u�I+ V 1 1`i�i
8168'-J'
10'
YECH GRILLE �" � '� Y� I 0.VEA DRAIH � I B�fi)'_ I p � I I g 3 �
RE NECH. � _���,�{��� CONNG�ODR � -LEVELIpqRKING ARFF OFYN I 9 /� 8 13
UwGS.�u ,;;.�^. ' �f-uouSiNC ABWE�a' ,�1 p�1 I I xG oiiu 4. . II '� � � � �
�1+f .?'�' I 4'�
I B 3 i ,-�. I . �
.','{;�t. ,.,fi;�'/ I I 4
—� , ___ � //� � __- 9i6�'-l' � � � \ � v m
d
__ �uGHt n�rua65 rr � 13 3 �m
--1- _ J __;� _ _ 10' 9�68'-a'.L 8�68. 6" y � 816B. �..
-- 12'SLffyE L1.Bf V. JT��` � �
ei6� 0��2' -— — --- - AT OF
I I 36"DEE BEAM t � — — -- i--� � —-—- Vl�II. R�'�S�R S
I ai '-a' � mi mHCa ae
I N. LOOR
I I i e' ii ' ii 3• 5g-p DEVELOPMENT
� ° i COMPANY
n i i
I I �voa,winrt�m
DFNE � I. I IN$ALL A5 TI6Hf 8� fI Wi��0� nLL n9WE �'{I ��
I I A2f 2 � TId1LiLFiE A$ I I I 4GI�
w�u���`�" �� ARCHfTECTURE
__—�- _---_—_ _ - - — aE�.uro� I I P26 j I — .
� � _� _ _ � _ _ ___ ' _ __ ' _ ���` " 1 ' -
� e�B�.�, ��.�
_ , �. ����� :a
� I I O01t1 r0 PI i /z�b"oEEC eEnH - - - __ ouhn _ �' ��..maev.�.s..e
/\ B 6B'-3
_-__—�--�-�__�__-__�___ __ I_ _ b I Bi6 -9" -_
�J -�- IEil32' �I � I �IDI.41 B• e�6a-io' � ��
I I � 8�69-0" �E%RUSMFAN
00 �q��
a2ii •
� I � 4 G1. .4' ' �� iu.ma�.c
._Q. I � � 12, � \`g �
4 er6o.J.. IISI'-)l4' / � � �^�` .
I I `� /
PROJECT N0:2001-1}4-0]
/ TO FvP �
I I II I � �• �A-PI �aIV i � DOYN TO �� IGIION
� � � EA DRAIN � OW IN T�_ 1 9�ii 9 A21 � I � 01 01.1��,01 PoM LA6'IRCIW
I 4
Z I i ia /
� IE 5' I D15H ' �/ I � MNd i00 OkPf IID
IKEYNOTES o ' � 1NE0G '�" , s •,o� � / r.wcoa,.
QI 4'STOfU7 p7yi1 TO LEVa�p}'� �
I Q 8'STqUA pOyd�TO LEVEL ggp(II�`,
Q3 4'STORM UP TO ARFA pRqIH F6�TO SV�T ppqp�
E%AGT LfX.ATiON AT 6R,qpE. I �
I Q4 4'STORM UP TO 4'AD-](,a'�AT TOP OF STRLGlLR.4L pEGK I
6ELOW FINI51��pqpE,�, p-�
QS 10'STOWi ppyN Qgpy RaR�pyIDE 4'WLO.LOLATFD 18
� ABOJE FINISV�p�(�y, �
I 6 6'SiLGt L�W�ggp{�r{q�Fppy�pE 4'Y1G0.LOLATID 18' I
FPOVE FINIS!$�F�q'�
Q7 3•STOFAI U'TO PFEA DRAIk TO 5V$T P040 POR EXPGi
� ILL�4TION AT 6Rp�DE.
QB 4'STORM STIGK. I� I
O L.aATOl/WT{�ryFRLM GML IN�T.C.Q7RDINATE EXIGT CONffGT10N
I � I/1'GW MD 1•DRqIN LP TO SILI�OGK/�gpyE,
n VEAT TRALE AI�INSI,LA7E R P62 ISOSO SpEGIFIGATIpM
i� 8'STORM FRpM RO/.P IN.ET. TO GIVIL iOR Cp(}iWATION,
19 4'DRAIN UP TO 4'�i LCLA AT F1�OL 11ATERFROOFIN6 Q
i urae.rsE,n�vim i
I Q RAfiE POOL WATB3PRq;p I
ID'ABWE F{�IN A NSIBLE �+Oµ��MIHATE P�FE
COHIRALTORiBUILDIHS MAI OF A R�L LEAK
� ABOVE FINI51fi�FLppRR0.�R I PRpyIGf 4'WLD.LOGAT�IB' I
�y GONEGT 4'SiORM TO TRBIGN IN�TO SFffT PIp1 I
FOR GONfIWAT1011
� � A51
I �
4 4 � I I
I
DR E t5)'_)Jre' �/
np-o
� I
I I \ \ `I\\ ` /
\
Bi60'-6�/2" �
\\ /
I I I / � ` /
/
k.
� I �
2 I GIV DETML '�\ � �
CUPB wLF �
0o rv �
� � � ei�ia'
I \
I �
I
� - I
LE6EN
� r�,x,Pxux i
i i
/ \ I . .i
entDiraY �q.u.�NS s�r��ae I
�nrA e� I
� REiDiPl01 �
Iw���n� �oi I 19�.8 1�
I �
� � I
� � � � i �
�i1PARKING GARAGE/t p�INC DOCK—PARTIAL b•ID 1 FVFi pT itb�gin* p AN 0 ITH
/
/ I �v t�,ur�
/ � ,,,�uUa O
o Pc3
i
aoo
i/� � f O�a
9 �a
I addnl Q Inldiry
�I / \[
/ /
� BUILDING A
� MID LEVEL
%��� ' ; r�y; GARAGE
'- ---�i/ PLAN—SOUTH
' -� .
r �' P 10 5
I�Y
SCALS: 1/B" = 1'-0'
�
r�,aviot
i ',
�PIP'� iNFLl ypg RE�.SiRUCt � �..�
7 / 4� / O
�3 � O
I � � P SUB t0 WiiHW ��� AL&IILUINC
3 NL ROOR . �'� B PLWS
fOR PI% /1
\ j 3 � /% � �.�.��
I / \
I I "_�-
R -- --- --i-- � _�--�_�-�-�--�-- �—=- -- _—�---I � I ------------ ,'� U'
a ' ,— ---- --- ----- -- -------
-- ---- ,-- ---r— \� --- -- --- - � �t f ---- ---
----,---- �
� � �
� T � � � — ,.a , z
� � ----�----
\ � �—_—_ ___ S[p
------, , I � ! � � 6 � I �� -t�--_-,-_._-- - -- ------- ------r -- � A
, ,
� � �--------r I , � .
� � � q � p� -r
% /,�'� I �a23-� I I ,� � \�i°5 'r \ � i _ I—aN
PE�NPIOS , � '-- �PIPIN6 / 1� �
. FOR PIPR�I6 � ''I `r 1 F+�1
O r-�_'__ '_ I___'__ __'_' '—__ '_'�L'__�, � / R�Eo�,Q�105 ` I I — I 4�1 i I ,
'
i
� � �,�p
, _I__ 1 vi� IA �ab23 1
. ,
I I ' —_ _—_ _— __ ' _—_—
, i I - — -- -�- �� ^
, I I •�_� — — — — — --�
.
� ° - - - - -
�
�---------- � , T -- --- =--� ---�
4
I I I I I ' � I I � I I I i I — �� � �
' _— I _ , I IQ �� I ��1�P�I � I , � 1 p I� �
N —_—_—_—_—_� � _ _— —_ _ _— I I d2-1 I CONCRCt(��VPBE\ I // 5'�'
� — _ WALL �
_ _ iCA
_ _" I
_ L
_ __ �
� '— I ING
" _ 11D ..� .
�
—� _ __ I RE. '�� )
i __
_" — _ ,
I �� -'"_�—-_I � I —_— —" _ _ _—_—_
' �"__"" ' ' I I '— ___ ' _'_
' i �O "—___ _ "
I � i . i I I \ . —_— • `
I I �� I
i
I Woll�
�
y
� -. �D"�
�/
` .'.,.
�� ''
I � �"" � xE BU0.UINC 0 Pi,WS
�---------1- , 4� � �
� � I � �OR SiEEL�MU.IxG � p��pepgqp�
LS --------�----- -�,'- - I - -�- �- � �� VAIL RESORTS
g__ ____�_____�_---_, �____�__ __ L-- _ ----�-----�-- — �-- __r_ __ ,� j _'�,� DEVELOPMENT
, � �
, ,
' � o L \
' .l- ' iB
� !/ _� COMPANY
I \ _ _ � \ �oON,COLIplDO
I "____,____"""- ` - � R:BIIINING o
�„_ 4. i i '[%ANS /
I FE�Nfl05 I I 5 k'
i i .FOR PIPI 2 o I T /� .�.i 0
I 4� ,-� I � / \ t`� 42�40
I I `� �`,, � ARCHRECTIJRE
�' , �� �
_ � o...�.
2 - ' /-- /
I - _ -�`
I RE BUiIDiNC `_"_ _ �/ /1
I I E%ANS 5 a� OvEn I I I I I / \ / � �LL
I I � r�o I i \ i / -� „� / j 'e°u�_� °`
,
I _
,
I I �_.
� � I � �
� � � � � I �
\ / ;
, -
-------------�------------�-------------- , _
------- I �--------�-, , � jl -
J � �
------ �� I I �
---- , I , , , �
��
, ��
----- , � .�,�,m
---- � � � -
,
--- ,
--------- � - � , .- � �
� � ------- , , j � , -� _ � j/ � : % , �,.;��.�
, , , .
I � �' � _
I I ' ' ' '
, � � „ ,
, � _ ,
� � _----
I � ' � �_ - � � - -
� � �---------_j I \ ...
.� ;,
I � � I
I I � j ,' % � � "'� vnaecr Ho:zooi ,�.o,
I i I I I / _ �'� / � �f0��� �,\ `, � 0. M IPf10N
I i i i i i � � � ,��,� ��-�' � ��
�� o, o,.,ob �,��
� � � � \ � '�_ � K.9
I I I I I � / a.wm sx otvr um
25 �2a �3 / �,\ f� %��� �� rwiww.
/ tiv,tm�
22 21.3 / ����
202 19.8 19 78 17 / \ % ' / � �,-- � ' �,
N / �� ' 7 ��
`�-
� � � % ���� � ���
�K�ING RAG /LOADING DO ID PLUMBING PLAN � ��_ ' -��� �
� � � � � ��\ F.6
16.; % �
\,
\,
OIGEI'NOTES ���4 ,a� � � � ���_
i o2ain wix Poo�w..ex��ir�s.coor�irv�re wn�sro vr5�sw � /� / E.5
3 COORDINATE FXA[.T LOLATION OF 6hRK�E LID DRAIN WTH 57W7LiLW�.p�},N �2'.3
a caoFCr r sror+�To�owt�cvr Hoza.E cc+a�in,�h�r�.ocpnor�w.M % i R E E D BY
a+.�rutiss r-oR san��raa
(0 8 �.. ��CS O
A51 4 `/ /
LE6END i9� �"� o�a o p
- rsF/,,w�«
euitDir�-� �NS s�r tu�at
e,uft+�.�,
RE�D/PIO\I
BULDINS 9'� `5�T PIOI
����
��l �i ��V�t'�
\\
COLORADO IN PECTION
AGENC
� ' ��o
9 aa
eridR(k LO�d10(
BUILDING A
ROOF PLAN
P 10'7
S�ALE: 1�8• _ ,•-�-
� , =- _= ._
�,"'-•,.�
- -
--- - _
ALPINE EPJGiNEERING, INC,
Sep2ember 7, ZOOt�
ti1r. Rick ('audel
Vail Resorts Devclopment Co.
P.O. Bc�x 959
Avon. CO 81620
RE: Vail's Front Door
SL.'I' Downspout
Dear Rick,
The capacity��f the 6" PVC pipe th�t outtalls Downspaut #4 and the are3 inlets for the
west side c�f the South Lodge Tower is I.03 cfs at a 2°ro grade. The calculateci 100 vear
fl�w fi'om ihe roofs is 0.075 cts. -
Therefore the proposed pownspaut #4, area drains and 6" PVC have adequate caparit}�
for the tlows. The 6" PVC pipe w�il discharge into Manhole P32 in the Vai] Road storm
� sewer systcm, which has adeyuatc capacity for this flc�w.
Please do not hesitate to call with any yuestions or comments.
Sincerely,
���-�.,f0
����
Heiko Mues, PE
Cc: Bob Herbst
_ -__ --
-------
--__ _ .------— -- _
F�41'dtt�t 5!e�l�t'jt�t?i,l?(' Fl�.�Ok !�1 • E�iYdCuS,�O�ll!dd0 i`�IF.? • iy' } �} -- --
�� t0, h jji� • F�� r),'tl� �'h ;;}:;7
___ ___ _ __ _ __.
� _ . __ __ __-- . -
w
z
�
�
J
�
d.
C
M
O
C�
O
�
O
O
N
r
O
m
O
V
O
O
Q
�
Q
�
3
a
�
�
O
F-
�
a
O
�
a
a�
�
ti
�
�
3
�
'v
c
0
�
a;
>
O
�
a
TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT
75 S. FRONTAGE ROAD
VAIL, CO 81657
970-479-2138
NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES
PLUMBING PERMIT Permit #: P06-0076
g D!�DD/S�
Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED
Location.....: VAILS FRONT DOOR-SITE/BUILDING 'A' Applied . . : 08/O1/2006
Parcel No...: 210108278002 Issued . . . 08/03/2006
Legal Description: �7r ea—OOo�B, Expires . .: O1/30/2007
Project No : ./
OWNER LODGE PROPERTIES INC 08/O1/2006
PO BOX 7
VAIL
CO 81658
APPLICANT HEATING & PLUMBING ENGINEERS08/O1/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 353-P
CONTRACTOR HEATING & PLUMBING ENGINEERS08/O1/2006 Phone: (720) 274-0073
715 VALLEJO STREET
DENVER
COLORADO 80204
License: 353-P
Desciption: PLUMBING WORK FOR NEW PARKING GARAGE INCLUDING PIPING, SUMP
PUMPS, SEWAGE EJECTORS AND DRAINS
Valuation: $271,536.00
Fireplace Information: Restricted: ?? #of Gas Appliances: ?? Jt of Gas Logs: ?? N of Wood Pallet: ??
********************************************************************* FEE SUMMARY
**************************************�******************�:**
Plumbing---> $4,OsO.00 Restuarant Plan Review--> $0.00 Total Calculated Fees---> $5,103.00
Plan Check---> $1,0 2 0.0 0 TOTAL FEES--------------> $5,10 3.0 o Addirional Fees-----------> $o.0 0
Investigation-> $o.o o Total Permit Fee----------> $5,10 3.0 0
Will Call-----> $3.00 Payments-------------------> $5,103.00
BALANCE DUE---------> $0.00
*****************************************************************�:******�********************************x**********x******�****************�****
Item: 05100 BUILDING DEPARTMENT
08/O1/2006 JS Action: AP
CONDITION OF APPROVAL
Cond: 12
(BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE.
*************************�******************************************�***************************�*****x******************************************
DECLARATIONS
I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot
plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply
with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design
review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto.
REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4
PM. /�/,/�(��`�v 6
%
*******�****�**�***************�*******************************************�*******�********
TOWN OF VAIL, COLORADO Statement
**�**************�x*******************:�******************�***********************************
Statement Number: R060001142 Amount: $1,030.00 OS/03/200612:09 PM
Payment Method: Check Init: LT .
Notation: HPE / ck 93866
----------------------------------------------------------------------=------
Permit No: P06-0076 Type: PLUMBING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A�
Total Fees: $5,103.00
This Payment: $1, 030.00 Total ALL Pmts: $5,103.00
Balance: $0.00
*********�x�************+***********:x�********************:x********************�x*************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PF 00100003112300 PLAN CHECK FEES 1,020.00
PP 00100003111100 PLUMBING PERMIT FEES 7.00
WC 00100003112800 WILL CALL INSPECTION FEE 3 .00
-----------------------------------------------------------------------------
********************************************************************************************
TOWN OF VAIL, COLORADO Statement
********************************************************************************************
Statement Number: R060001130 Amount: $4,073.00 08/01/200604:48 PM
Payment Method: Check Init: JS
Notation: 93788/HEATING
AND PLUMBING ENGINEERS
-----------------------------------------------------------------------------
Permit No: P06-0076 Type: PLUMBING PERMIT
Parcel No: 2101-082-7800-2
Site Address: 174 GORE CREEK DR VAIL
Location: VAILS FRONT DOOR-SITE/BUILDING 'A'
Total Fees: $5,103 .00
This Payment: $4,073.00 Total ALL Pmts: $4,073 .00
Balance: $1, 030.00
********************************************************************************************
ACCOUNT ITEM LIST:
Account Code Description Current Pmts
-------------------- ------------------------------ ------------
PP 00100003111100 PLUMBING PERMIT FEES 4,073 .00
-----------------------------------------------------------------------------
APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG Q � -7 �
Project #: "`i �� V� `�LJ
• Building Permit #: p�-po��
��Q�Y�� � �. �`� Piumbing Permit #
� 970-479-2149 Ins ' ��
� P t� �
75 S. Frontage Rd.
Vail, Colorado 81657
TOWN OF VAIL PLUMBING PERMIT APPLICATION
CONTRACTpR INFORMATION
Plumbing Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s:
, �4,A�bi - � 3S 3 — P �ffM�C
E-Ma� Address: u Zd` �!� �Z.i �{
�" i � 1NG Fax#: ��p � Z7� `� � t
Contractor � nature:
COMPLETE VALUATION FOR PLUMBING PERMIT(Labor& Materials)
PLUMBING: $ �`� I p j� �,4���,,�
Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www,ea /e-coun ,com for Parce/#
Parcel #
Job Name:�'q`,'lS '�"'"T AwR �k�'tce�� /�.
5 )ob Address: �7`� �'+'� �cK a+2,
`` � Sl S'?.
Legal Description Lot: Block: Filing: Subdivision:
Owners Name: �/},2 CSvr- S Address: d• �K q S-Q Z
Phone:9'7b� �'YS-z 3.5 z�
Engineer: �S Address: �S3v r�a'*► sT S�s� yrm Phone:
Detailed description of work: P/u,��„� ��K Z" 3°3"6 Z 3 '(Z c a
� �X� .r� Pr PI�t �
Su.�P F k�n c�J S `� C�c,�y+s t- D,e,1.�n 5 .� G'�C- �a�l.�c aL� V 5
Work Class: New(� Addition ( ) Alteration
( ) Repair( ) Other( )
Type of Bldg.: Single-family( ) Duplex( ) Multi-family( ) Commercial
( ) Restaurant( ) Other( )
No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building:
,�*��,�,�,�*���*�*�*x**,��***x���,��*�x*,�*�,��
FOR OFFICE USE ONLY***********��****,�,�,��***�,�,�*�,�**,��*,�*
Other Fees: Date Received•
Acce ted B :
U� (� i� ___._.
� � 3 ..� � � � ov � �
D
F:\cdev\FORMS\PERMITS\Building\plumbing�ermit_i1-23-2005.doc AUG U 1 2006
Page 1 of 1 11/23/2005
TOWN C�F VAiL
� . `��_ oo� s
''�2 S c��, � U a ��S
, KL�A, Inc.
Structural Engineers and Builders
� Golden, Colorado Loveland, Colorado Falmouth. Massachussetts
July 27,2006
Mr. Matt Royer
Colorado Inspection Agency
P.O.Box 1618
Eagle, Colorado 81631-1618
Re: Vail Front Door,Vail ,Colorado
STR UCTURAL ENGINEERING PLAN CHECK
Architect: 4240 Architecture
Structural Engineer:Monroe&Newell Engineers
Dear Matt:
We have completed our review of the above project for compliance with the 2003 International
Building Code and the Town of Vail required structural design criteria.
Our wark has consisted of the review of the project structural drawings and structural calculations
submitted far permit. We have also briefly reviewed the other documents submitted(geotechnical
report, architectural and mechanical drawings, etc.) to help us interpret the structural drawings and
foundation requirements, but have not reviewed drawings other than structural drawings far code
compliance. We have not performed a multidisciplinary review or a coordination review between
structural and other disciplines. We have performed an overall structural review with detailed spot
checks of specific locations, in the attempt to verify that the intent of the building code has been
achieved; we have not numerically checked one hundred percent of the structural members or
connections.
We have reviewed the following sets of drawings and structural calculations,Volumes I,II,III, IV,
V,and VI:
1) FOR CONSTRUCTION, dated 10 January 2006, including structural calculations and
specifications
2) ADDENDIJM#1,Dated 24 January 2006.
3) BLDG. DEPT. RESP./ FINAL CONST., dated 3 April 2006, including revised sriuctural
calculations and specifications.
4) BLDG. DEPT. RESP./FINAL CONST., dated 15 May 2006, including revised structural
calculations and specifications.
5) Temporary shoring package,dated 23 May,2006,including structural calculations.
6) BLDG. DEPT. RESP./ FINAL CONST., dated 5 July 2006, including revised structural
calculations and specifications.
805 14th Street. Golden. Colorado 80401 ■ Phone: 303 384 9J10 ■ Fax: 303 384 9915 ■ Website: www.klaa.com
t `
7) Additional follow up structural calculations and structural sketches, dated between 5 July
06 through 14 July 2006.
During the course of our review,we have raised structural code issues and errors ar inconsistencies
in the drawings to the attention of the Engineer of Record(EOR),who has in turn responded to and
resolved our concerns. When a comment was resolved by modifying the construction documents,
we have not reviewed the modified drawings in all cases; we feel that it is the EOR's responsibility
to ensure that changes to the structural drawings made as a result of our plan check are properly
communicated to the contractor for construction. Note, the 2003 International Building Code
requirements for Structural Observation and Structural Inspection are beyond the scope of our
review,these duties must be carried out by the EOR and a third party inspection agency.
At this time, all structural plan check comments have been addressed by the EOR and are
considered closed. It is our professional opinion that the project conforms to conventional design
and construction practices and meets the minimum requirements of the building code. Please note
that the completion of this review does not absolve the EOR of ineeting any section of the building
code not explicitly addressed in the review, or allow the violation of any State or City Law, or any
other ordinance.
Please do not hesitate to contact us with any questions or comments.
Sincerely, �pp0 !/C�
p�,� ,,.......
•�S P.H�q,`�'c�
c,,��� ti�:o
610
James P.Horne,P.E., S.E.
Project Engineer '��
., . �
SS��NAL E�\
cc. David Thomsen, CIA(electronic file)
.
� ��7`
H�D ER To�� a$ �a�� � �
CONSTRUCTION INC . � ��
� � ��
�k
�� ,.: �,�•:
May 22, 2005
�
Mr. Leonard Sandoval
♦
Town of Vail Department of Public Works
1309 Elkhorn Drive
Vail, CO 81657
RE: Construction Site Access and Sta in�lan_—Vail's Front Door
_---
�
. Dear Leonard,
Following is a summary of the site staging'and access plan for the referenced Project:
I. Reference the attached Project Schedule representing a start date of May 30,
2006.
A. The construction schedule is based on Monday through Friday 7:OOAM to
5:30 PM and Saturdays 7:00 AM to 4:30 PM
B. The 2006 Vail Village/Lionshead Village Construction Hours Information
Handout for holiday hours is incorporated into the Project Schedule.
C. Hyder Construction will provide weekly schedule updates to the Town of
Vail.
D. Hyder Construction will continue to attend the weekly TOV coordination
meetings to update the progress of the project and its impacts upon adjacent
properties.
II. Attached are three (3) separate site access and staging plans
A. Site Access and Staging Plan#1 represents the work period of May 22, 2006
through October 31, 2006.
1. Plan#1 is intended to work concurrently with the previously
approved Site Access and Staging plan for the spring utility work in
the Public Right of Way. This work is operating under a separate
Right of Way Permit. The previously agreed upon Vail Merchant
Delivery Zone will be maintained until road closures are no longer
required. Currently the last road closure is scheduled to be
completed on June 10, 2006.
2. During this period the site will be accessed from Vail Road on the
west and from the east via Vail Valley Drive through the Gold Peak
area.
i. Reference MHT#2 for the traffic control plan for Vail Road.
ii. Reference MHT #1 for the traffic control plan for the Gold Peak
Children's Center.
543 Santa Fe Drive•Denver,Colorado 80204•(303) 825-1313•Fax: (303) 825-3223•Email:infoC�hyderinc.com•Website:www.hyderinc.com
iii. Pending the Town of Vail's approval the bus stop at the Gold
Peak Children's Center will be relocated to the Gold Peak turn
out.
iv. A fence will be installed at Gold Peak to separate construction
activities from the public.
3. Vail Resorts intends on using the Vista Bahn ski lift and surrounding
ski yard for limited summer activities.
i. Hikers will be allowed in the area adjacent to the construction
activity per the signage and fencing requirements shown on Plan
#1.
ii. Bikers will not be allowed in the area and will be blocked at
Rock Ledge Road. A map will be installed in the Vista Bahn
plaza directing bikers through the town to get access to the
mountain.
iii. The ski yard will be separated from the construction site by an 8'
tall painted plywood fence.
B. Site Access and Staging Plan#2 represents the work period of November
l, 2006 through Apri122, 2007.
1. During this period the site will be accessed from Vail Road only.
i. Reference MHT#2 for the traffic control plan for Vail Road.
ii. The bus stop will be re-established at the Gold Peak Children's
Center.
iii. The access road to the east will be restored to its current
condition and all storm water management BMP's will be
removed.
2. Vail Resorts intends on using the Vista Bahn ski lift, surrounding ski
yard and ski runs for their standard winter program.
i. The ski yard will be separated from the construction site by an 8'
tall painted plywood fence.
ii. Skier signage will be managed by Vail Resorts.
C. Site Access and Staging Plan#3 represents the work period of April 23,
2007 through October 31, 2007
1. During this period the site will be accessed from both Vail Road and
from the east via Vail Valley Drive through the Gold Peak area.
i. Reference MHT#1 for the traffic control plan for Vail Road.
ii. Reference MHT#2 for the traffic control plan for the Gold Peak
Children's Center.
iii. Reference MHT#3 for the traffic control plan for access to One
Vail Place.
iv. Pending the Town of Vail's approval the bus stop at the Gold
Peak Children's Center will be relocated to the Gold Peak turn
out.
2. Vail Resorts will close the Vista Bahn ski lift and surrounding area
for the relocation of the lift and the associated utility and grading
work.
. �
3. The pedestrian streetscape work around One Vail Place, the Hill
Building and Bridge Street Lodge will be performed in three
separate phases as depicted on Plan#3.
D. Work occurring after October 31, 2007 will be performed under a separate
site access and staging plan similar to Plan#2. This plan will be
submitted to The Town of Vail by September 15, 2007.
III. Access to and from the site will be managed from a check point at the delivery
zone on Vail Road.
A. The construction access trailers will be located at the south side of the site.
Visitors to the construction trailers will be directed to access from Bridge
Street.
B. A temporary Knox box will be located at the delivery check point to
provide keyed access to any area of the site in case of emergency.
IV. The site will be surrounded by either a 6'-0" chain link fence with two layers of
green fabric depicted in red on the attached access and staging plans. The areas
of the site that are subject to high pedestrian traffic will be surrounded by an 8'-0"
high painted wood fence depicted in green on the attached access and staging
plans. All fencing will be installed to withstand winds of 80 miles per hour.
Snow adjacent to the plywood fencing will be managed to maintain a clear height
of 6'-0" for the safety of the public.
V. An emergency egress plan by 42/40 Architecture showing egress patterns from
affected areas of the South Lodge Tower,the Lodge at Vail and the lower level of
One Vail Place is attached.
VI. Signage will be placed along Vail Road to direct pedestrian access to the Vista
Bahn ski lift via Gore Creek Drive to Bridge Street in both the summer and winter
seasons.
VII. Vail Resorts will install a pedestrian barrier in both the summer and winter modes
to increase the separation between pedestrian traffic and construction activities on
the mountain. The Vail Resorts barrier is shown in blue on the attached access
and staging plans.
VIII. Homeowners and merchants in the surrounding areas will be provided with notice
of the construction site access and staging plan once the plan has been approved
by the Town of VaiL
IX. Temporary task lighting within the construction site will be provided to meet
OSHA standards and will comply with The Town of Vail lighting discharge
requirements.
X. Two tower cranes will be erected on the site. The tower cranes will be erected so
as to allow 20' of clearance under the crane hook above the highest projection
around the site. No crane pick will be allowed over occupied areas or buildings.
A. Aviation beacon lights will be mounted at the tops of each tower crane.
B. Two emergency drop zones are shown on Access and Staging Plan#1 and
#2. These may be utilized in the event of an emergency to evacuate an
injured person from within limits of construction.
C. Mobilization and removal dates for the tower cranes are shown on the
attached schedule.
' � ,
XI. Concrete truck and concrete pump wash out will be allowed only in designated
areas within the limits of construction. Prior to completion of the project these
wash out areas will be remediated.
XII. Mill Creek Circle will not be used for construction access at any time.
XIII. A detailed SWMP is attached for reference.
A. Copies of the SWMP and construction dewatering discharge permits have
been provided under separate cover.
B. Street sweeping will be provided at both the Vail Road and Vail Valley
Drive access points as required to minimize dust and vehicle tracking.
C. Dust within the site and on the Gold Peak access road will be mitigated
with the use of water trucks. Magnesium Chloride may be used on the
Gold Peak access road if required.
XIV. Snow removal from the material delivery zone and from within the site will be
hauled to an off site stockpile area. Vehicle tracking at the material delivery zone
will be managed with gravel and/or de-icing compound to maintain safe access
points.
XV. All construction personnel parking will be managed offsite.
A. During the summer building season the Village parking garage will be
utilized.
B. During the winter building season a remote parking area and buses will be
utilized. Currently the remote parking area is planned to be near Gypsum.
Details for the parking area will be provided once they are available.
XVI. The interior and exterior renovation of the South Lodge Tower is scheduled to run
concurrent with the summer 2006 building season.
A. Modifications to the east stair tower are required to avoid construction.
An emergency egress plan by 42/40 Architecture dated May 4, 2005 is
attached.
B. A separate site access and staging plan will be provided for this project.
XVII. Names and contact numbers for Hyder Construction are listed below
A. Doug Thompson, Project Executive
Office: (303) 825-1313
Direct: (720) 932-3264
Cell: (303) 829-5950
B. Scott Miller, Project Manager(Site, Parking Garage, Chalets)
Office: (303) 825-1313
Direct: (720) 932-3271
Cell: (303) 882-6238
C. Chris Knight, Project Manager (Lodge at Vail, Alpine Club, Skier Serv.)
Office: (303) 825-1313
Direct: (720) 932-3284
Cell: (303) 358-3607
D. Jim Benvenuti, Project General Superintendent
Cell: (303) 829-7145
Site: To be provided
E. Rene Robledo, Project Superintendent (Site)
Cell: (303) 829-1331
. .
• .
Site: To be provided
F. Bill Partridge, Project Superintendent (Parking Garage)
Cell: (970) 471-5729
Site: To be provided
G. 24 Hour Emergency Number
(303) 489-5208
We recognize that there will be a considerable amount of construction activity within the
Town of Vail occurring concurrent with the construction of the Vail's Front Door Project.
We understand that modifications to the above plan may be necessary for the work in the
area to be completed successfully and on schedule. We will cooperate in anyway feasible
recognizing of course that we are also under a very tight construction schedule for the
completion of the project.
Sincerely,
HYDER CONSTRUCTION INC., by
� ��,�-�
Scott Miller, Project Manager
cc: Mr. Rick Caudel, Vail Resorts Development Co.
Mr. Brian McCartney, Vail Resorts
Mr. Charlie Davis, Town of Vail Chief Building Official
� �
"'�,_,-.�
'�. %��1 :CC ENTERPR I SES FAX N0. :970242053� Apr. �6 2086 01:50PM P1
R�L,��V •
� ■ i
f ■
�7 ■ ■
■ ■
CC ENTERPRISES - TRAFFIC CO�ITROL SPECIALISTS, INC
ContraCtor; HYDER CONSTRUCTION PAGE #1
Project: VAIL FRONT DOOR (VAIL VALLEY DRIVE)
Method of Handling Traffic; TRUCKS TURNING ON 2 LANE ROAD
N
� �j PREPARED BY; �' E
tJ �. .� �' �
�i�n �� n�r , .��/J/5�06 S
ATSSA TCS NAME DATE
n,.Kacs ff�_ "''
�- z
Nf:NING � � � � � .
aN Hwv p
}
2��� �
>
�
a
�� ��1� y
�� z���:�
tur,Ninic�
ONF
2���
, �� �
FARI(mx; N �
,�r �
� `-�~-
l�' -'
. . . � �___r,
'�_�
�
��
NA���oAO �oo-
GRP���
■�
NOTES:
1. CONTRACTOR WILL HAVE TRUCKS TURNING ON AND OFF VAIL VALLEY DR„ DURING WORKING HOURS ONLY.
2, FLAGGERS ON VAIL VALLEY ROAD WILL STOP TtZAFFIC FOR TRUCKS TURNING.
FLAGGER_ON GRAD�p HAUL R4AD WILL STOP TRUCKS F�R PARKING LOT TRA�FIC,
51GN5 & DEVICES:
2 - TRUCKS TURNING ON HWY 3 - FLAGGERS SYMBOL
•� F";UM :CC ENTERPRISES FAX N0. :9702420530 Apr. 06 2006 01:51PM P2
CC ENTERPRISES - TRAFFIC CONTROL SPECIALISTS, INC
Contractor; HYDER CONSTRUCTION PAGE #2
ProjeCt; VAi� FRONT DOOR (MILL CREEK CIRCLE)
Method of Handling Traffic; TRUCKS TURNING ON 1 LANE ROAD
PREPARED BY; N
�i�nT�i/ n��a�. //Oh%�' w E
, ATSSA TCS NAME DATE
s
wrccownoq�
� ���
o�
ri��Kacs �
� IUfMNC: �� . . .
pN �GJ � �
� �l
' � �� � � 2O�' . � �r� .
'�„��, �
E FOREST ROAD � 200' \�
y
200'
WORK
SITE
,u„"`�,� 'i"' ENTRANCE
ON I IWY ��
NOTES:
1. CONTRACT�R WILL HAVE TRUCKS TURNING ON AND OFF ROAD AT�NTRANCE TO WORK SITE.
2. FIAGGER AT E FOREST RD AND VAII.RD INTERSECTION WILL ALLOW LOCAL TRAFFiC TO PASS THROUGH
AND CONTROL DELIVERIES TO THE SITE. THE FLAGGER AT SITE ENTRANCE WILL CONTROL TRUCI<5
LEAVING THE SITE AS THEY ENTER THE ONE WAY
SIG NS:
2- TRUCKS TURNING ON HWY 2- FLAGGER SYMBOL
,
� -
1000 'Mobilize-Job Site Set Up
__ -- - - --
1010 Site Demolition
1020 Layout
1030 CleadGrub Site/Prep for Dewatering
1040 Relocate Utilities
&Shori
1045 _ Construction Dewatering Trench/Wells
1050 Underpining&Shoring
1060 Mass Excavation
1080 Erect Tower Cranes
1090 Cast-In-Place Structure
1095 Below Slab Utilities&Vaults
1100 Waterproofing at Deck _
1105 CMU Walls
1120 Stairs&Railings
1125 Fire Sprinker
1140 Mechanical Plant
1150 Electrical Service
1160 Rough Mechanical
1170 i Rough Electrical&Fire Alarm
1180 !Trim MEP&Fire Alarm
1190 Overhead Doors-Doors&Hardware
1200 Paint
1210 Final Clean&Punch
1220 Building A-Garage/Dock Substantial Co
2000 Relocate Operations in Lodge
2010 Complete Electrical Gear Relocation
2020 Relocate Mechanical Plant
2030 Interior Demolition
2040 Relocate Kitchen Hood
2050 Demo West&South Wings
2060 Excavate for Shallow Foundation
2070 Shallow CIP Foundations
2075 Backfill Foundation
2080 Below Slab Utilities
7'30MAY06 '07JUN06
5 01JUN06 07JUN06
5 05JUN06 09JUN06
10 06JUN06 16JUN06
30 08JUN06 14JUL06
24 12JUN06 11JUL06
95 12JUN06 I 030CT06
100 12JUN06 �090CT06
5 11 SEP06 15SEP06
140 11SEP06 16MAR07
15 030CT06 !190CT06 i
—20��0-5MAR07 30MAR07
30119MAR07 '27APR07
30 19MAR07 27APR07
40 09APR07 O1JUN07
30 09APR07 18MAY07
20 09APR07 04MAY07
40 23APR07 1 J5 UN07
40 23APR07 i15JUN07
20 04JUN07 29JUN07
7 18JUN07 26JUN07
10 20JUN07 03JUL07
5 05JUL07 11JUL07
0 i 11JUL07
10 08JUN06 19JUN06
10 14JUN06 24JUN06
20 14JUN06 08JUL06
15 20JUN06 ,08,JUL06
--+—
15 10JUL06 26JUL06
7 10JUL06 17JUL06
5 18JUL06 22JUL06
15 24JUL06 09AUG06
5 10AUG06 ,15AUG06
,
15 16AUG06 I 01 SEP06
VAIL'S FRONT DOOR
SUMMARY SCHEDULE
START DATE:
May 30, 2006
�'.Mobilize-Job Site Set Up
I�Site Demolition
ri Layout
�°'!CleadGrub Site/Prep for Dewatering&Shoring
�°��-'Relocate Utilities
��Construction Dewatering Trench/Wells
� Underpining&Shoring
� - -- Mass Excavation
�.Erect Tower Cranes
-��:�-=���r�*���_� Cast-In-PlaceStructure
�;'Below Slab Utilities&Vaults
�'Waterproofing at Deck
��CMU Walls
■r�t-_.,. Stairs&Railings
�:Fire Sprinker
�'Mechanical Plant
I�:Electrical Service
��-'Rough Mechanical
�'Rough Electrical&Fire Alarm
�Trim MEP&Fire Alarm
�:Overhead Doors-Doors&Hardware
�'Paint
�'.Final Clean&Punch
Building A-Garage/Dock Substantial Completion
:��Pii�'i O� �/ai�
� ,
� i
��Relocate Operations in Lodge
'��-'Complete Electrical Gear Relocation
�-��-'Relocate Mechanical Plant
�'!Interior Demolition
---'�Relocate Kitchen Hood
�-.Demo West&Suuth Wings
F+Excavate for Shallow Foundation
�!Shallow CIP Foundations
�'Backfill Foundation
�'Below Slab Utilities
�
2100
2110
2120
2130
2135
2140
2145
2150
2155
2170
2180
2190
2195
2200
2205
2210
2220
2230
2240
2250
2255
2260 -
2270
2280
2290
2300
2310
2320
2325
2330
2340
2350
2360
2370
2380
2385
2390
2395
2410
2450
2460
Pour Interior Slabs
- - --- _ __ __ _
Erect Steel-West Wing
CMU Sheath Exterior Walis-West
Dry In&Roof-West Wing
Set Windows&Doors-West Wing
Exterior Stone Veneer-West Wing
,Interior Wall Framing-West Wing
Rough MEP&Fire Protection-West Win�
Gyp&Finish-West Wing
Structural Steel-South Wing
Frame&Sheath Exterior Walls-South W
Dry-In and Roofing-South Wing
Set Windows&Doors-South Wing
Duct Work-South Wing
Elevators
Frame Interior Walls-South Wing
Rough MEP&Fire Alarm- South Wing
Gyp,Tape&Finish-South Wing
Interior Stone and Tile
Millwork, Lockers&Tirm
Floor Coverings
Final Paint
Final Clean&Punch
Buildinq B Spa&Lodqe Substantial Com[
Frame&Sheath Structure from 8188
HT&Steel Roof Framing
Sheath/Dry-In/Roofing
Set Windows&Doors
Elevator
Interior Framing
Fire Sprinkler Piping
Rough MEP&Fire Alarm
Gyp,Tape&Finish
Interior Stone&Tile
Miliwork,Lockers&Trim
Doors&Hardware
Kitchen Equipment
Final Paint
Floor Coverings _ __
Final Clean&Punch
Buildina C Ski Club Substantial Comc
5 04SEP06
20 09SEP06
15 030CT06
20 200CT06
5 06NOV06
30 06NOV06
15 15NOV06
30 06DEC06
15 19JAN07
20 05MAR07
10 02APR07
10 16APR07
5 23APR07
10 30APR07
45 30APR07
10 14MAY07
20 28MAY07
20 25JUN07
20 10JUL07
20 24JUL07
5 21AUG07
5 21AUG07
5 28AUG07
0
20 19MAR07
20 09APR07
20 07MAY07
5 21 MAY07
20 21 MAY07
10 21 MAY07
10 28MAY07
20 04JUN07
20 02JUL07
20 24JUL07
30 14AUG07
5 18SEP07
7 25SEP07
5 040CT07
5 110CT07
5 180CT07
0
08SEP06
020CT06
190CT06
14NOV06
10NOV06
15DEC06
05DEC06
18JAN07
08FEB07
30MAR07
13APR07
27APR07
27APR07
11 MAY07
29JUN07
25MAY07
22JUN07
23JUL07
06AUG07
20AUG07
27AUG07
27AUG07
03SEP07
03SEP07
13APR07
04MAY07
01JUN07
25MAY07
15JUN07
O1JUN07
08JUN07
29JUN07
30JUL07
20AUG07
24SEP07
24SEP07
030CT07
100CT07
170CT07
240CT07
240CT07
Pour Interior Slabs
�- Erect Steel-West Wing
�CMU Sheath Exterior Walls-West
�i Dry In&Roof-West Wing
l�Set Windows&Doors-West Wing
11�!'W�!`�`:Exterior Stone Veneer-West Wing
i Interior Wall Framing-West Wing
- . �:Rough MEP&Fire Protection-West Wing
��Gyp&Finish-West W Ing
:Structural Steel-South Wing
��Frame&Sheath Exterior Walls-South Wing
��°�Dry-In and Roofing-South Wing
r!Set Windows&Doors-South Wing
�'J Duct Work-South Wing
�'*��^�� Elevators
�_Frame Interior Walls-South Wing
i�-'-��Rough MEP&Fire Alarm- South Wing
�°'Gyp,Tape&Finish-South Wing
�� _Interior Stone and Tile
_-.- Millwork,Lockers&Tirm
!�:Floor Coverings
�'Final Paint
� Final Clean&Punch
Building B Spa&Lodge Substantial Completion
� Frame&Sheath Structure from 8188
�:HT&Steel Roof Framing
�-m`Sheath/Dry-In/Roofing
F Set Windows&Doors
�'E�evator
�"Interior Framing
�- Fire Sprinkler Piping
�^��_�:Rough MEP&Fire Alarm
�'"':Gyp,Tape&Finish
_... _Interior Stone&Tile
-. .- Millwork,Lockers&Trim
��Doors&Hardware
!�Kitchen Equipment
��.Final Paint
�Floor Coverings
D:�Final Clean&Punch
` Building C Ski Club Substantial Completion
4050
4060
4070
4075
4080
4090
4095
4097
4100
4105
4110
4115
4120
4130
4140
4150
4210
4225
4220
4230
4240
4250
4270
4260
4280
4290
4300_
4310
Set Steel at 8i70
�Pour Slab on Deck 8170
Erect Main Level Steel Framing 8182
'Backfili Foundation
--- - - - ---
'Erect Wall and Roof Framing _
Erect Heavy Timber Roof Framing
_ Prep&Place Slab on Deck _ ___
Interior Wall Framing_Lower Level_
-�-- -_
,Exterior Wall Framing __
_ Rough Fire Sprinkler-Lower Level
Roof Sheathing&Dry-in
-- - - _ - -- --
Rough MEP-Lower Level
— - -
Interior Wall Framing-Main Level
,Doors&Windows
-- _--_
Roofing
;Elevators
---� - - -- _
_ Fire Sprinkler-Main Level _
- -�--
1 Exterior Veneers&Trim _
Rough MEP-Main Level _ _
Gyp,Tape&Finsh-Lower Level
Gyp,Tape&Finish-Main Level
- -- - —- -
�Millwork,Trims, Finishes-Lower Level
MEP Trim-Lower Level
Millwork,Trims,Finishes Main Level
2470
2480
2490
2510
2520
2530_
2540
2550
2560
2570
2580
2590
MEP Trim-Main Level
Kitchen Equipment __
Final Clean&Punch
Substantial Completion-Skier Services
!Clear Snow&Grub Building Site
Prep Site for Dewatering&Erosion Control
Electrical&Phone Relocation�West
_ Excavation&Shoring-South&West_ _
Excavation&Shoring_-East __
Pour Pad&Erect Tower Crane
Cast-In-Place Garage&Mezzanine
__- - -- -
Foundation Walls-Chalets
Underslab Utilities
Slab on Grade-Garage
Vertical Waterproofing
Rock Backfill to Garac7e/Mezz Lid
10 02MAY07 15MAY07
2,16MAY07 17MAY07
- —
-
10 16MAY07 29MAY07
7 I 25MAY07 I 04J UN07
15 30MAY07 ,19JUN07
� 23 O6JUN07 09JUL07
-! - - '
� 4 20JUN07_ i25JUN07 �I
_�_10 28JUN07 112JUL07
� 10 02JUL07 �,16JUL07
� 10 06JUL07 119JUL07
7 10JUL07 Y18JUL07 I
- - -- -� --
I 15 13JUL07 02AUG07
10 17JUL07 30JUL07 _
5 19JUL07 25JUL07
20 19JUL07 15AUG07 �I
_ _ _ _- -- -
50 19JUL07 26SEP07 �
_ 10,24JUL07 O6AUG07 ;
� 30��26JUL07 I 05SEP07 �
15 31JUL07 _�i20AUG07 _��
I 15 03AUG07 �I23AUG07 �,
- r 15�'�21AUG07 �I 10SEP07
�_ 15 24AUG07 �I13SEP07 �
1_ 10 07SEP07 I20SEP07 �I
20 I 11 SEP07 I 080CT07 I�
10�020CT07 I150CT07 �
5 I 020CT07 I 080CT07 I
i7�'160CT07 �240CT07 JII
OII �40CT07 ,
5 08JUN06
3 14JUN06
7 17JUN06
45 26JUN06
_ 35 19AUG06
10 I 25AUG06
601 13SEP06
55 300CT06
10 20NOV06
4�0-4DEC06
20�26DEC06
10�17JAN07
I 13JUN06 I
16JUN06 '
24J UN06
18AUG06
129SEP06
06SEP06 �,
24NOV06 �I
��18JAN07
'01 DEC06 I
�07DEC06
I,23JAN07
�30JAN07
�°-Set Steel at 8170
�Pour Slab on Deck 8170
�Erect Main Level Steel Framing 8182
�Backfill Foundation
�!Erect Wall and Roof Framing
�-=°�'_Erect Heavy Timber Roof Framing
� Prep&Place Slab on Deck
�_Interior Wall Framing-Lower Level
��Exterior Wall Framing
�`-',Rough Fire Sprinkler-Lower Level
� Roof Sheathing&Dry-in
Rough MEP-Lower Level
w -Interior Wall Framing-Main Level
Doors&Windows
- Roofing
� '�- �- Elevators
1�!Fire Sprinkler-Main Level
���Exterior Veneers&Trim
_._�Rough MEP-Main Level
i Gyp,Tape&Finsh-Lower Level
� Gyp,Tape&Finish-Main Level
� Millwork,Trims, Finishes-Lower Level
MEP Trim-Lower Level
� -_:Millwork,Trims,Finishes-Main Level
�MEP Trim-Main Level
�Kitchen Equipment
�Final Clean&Punch
# Substantial Completion-Skier Services
►� Clear Snow&Grub Building Site
�Prep Site for Dewatering&Erosion Control
!�`Electrical&Phone Relocation-West
�" Excavation&Shoring-South&West
�"T°`�" Excavation&Shoring -East
�Pour Pad&Erect Tower Crane
�--"�-" ' Cast-In-Place Garage&Mezzanine
"v -'' "-Foundation Walls-Chalets
�`�Underslab Utilities
i Slab on Grade-Garage
��"i Vertical Waterproofing
-�Rock Backfill to Garage/Mezz Lid
2595 Horizontal Waterproofing 10 24JAN07 06FEB07
_ i - - - - - _ - - - - - - _ _
2600 CMU Walls-Garage_ _ ' 15 07FEB07 �27FEB07
- --- - - _ _ _ - - i __ --_ .- - -
2605 TFoamfill to Subgrade 15 07FE607 ,27FEB07 J
2610 Frame Bwlding 1 I_ 30 07FEB07 20MAR07
2615 _ Frame Building 3 30 07FEB07 20MAR0�
2618 _'Protection at Foam �, 5 28FEB07 ',06MAR07 �
- ---- -
2620 _1 Rough Fire SpriNkler-Garage 10'28FEB07 I 13MAR07
2625 I Basecourse Fill on Foam 10'�07MAR07 ,20MAR07
-- --- - - - - -- - - -,--
2630 Rough MEP&Fire Alarm Garage 15 07MAR07 �27MAR07
- - ___- --
2635 Dry-in&Roofing Building 1 15 21 MAR07 10APR07
-- - - - - r ------.
2637 Dry-in&Roofing Building 3 15 21 MAR07 10APR07
2640 Framing-Building 2 30'21 MAR07 01 MAY07 I
- - � -- - _- _ �
2645 Framing-Building 4 ', 30 21 MAR07 01 MAY07
2647 Doors&Wlndows-Building 1 � 5 28MAR07 ,03APR07
- -- ---_ - - - - �
2648 Doors&Windows-Building 3 I 5'28MAR07 �03APR07 I
_ - - . -- -
2649 Rough Fire Sprinkler&MEP Building 1 40'04APR07 �29MAY07_
2650 __ Rough Fire Sprinkler&MEP Building 3 _ _� 40 04APR07 I29MAY07
3170 Exterior Veneers&Finishes-Building 1 60,04APR07 '26JUN07
- - --- --- -- ---- - --
3180 Exterior Veneers&Finishes-Building 3_ _ _ 60 04APR07 '26JUN07 _I
2652 Elevators-Building 1 � 40 11APR07 05JUN07
-- - 9- -_ ---- -, --- --- - -- _
2653 Elevators-Buildin 3 40 11APR07 05JUN07
- -- - - - - -
2655 Dry-in&Roofing Building 2 15 02MAY07 22MAY07
2657 Dry-in&Roofing Building 4 15 02MAY07 22MAY07 �
-� g - - - — --
2685 Frame-Buildin 6 30 02MAY07 26JUN07
F - - --
02MAY07 12J UN07
2680 � rame-Buildin 5 40 ---- I
2690 Doors&Windows-Buiiding 2 5',09MAY07 '15MAY07
- -- 9- ___ _ _ i _ .I- — -.
2691 Doors&W Indows-Buildin 4 5�09MAY07 �15MAY07
- --- - --- --- - I _ _
2692 Rough Fire Sprinkler&MEP Building 2 40I 16MAY07 11JUL07 I
2693 Rough Fire Sprinkler&MEP Building 4 � 40,16MAY07 11JUL0�
___ --,-
3190 Exterior Veneers&Finishes-Building 2_ _ i �16MAY07 ,08AUG07 i
3200 Exterior Veneers&Finishes-Building 4 ' 60I 16MAY07 '08AUG07 '
2870 Gyp,Tape&Finish-Building 1 40 30MAY07 25JUL07 '
-- ---- � �
2880 I Gyp,Tape&Finish-Building 3 40 30MAY07 25JUL07
- _ - - - - �- ---'
2695 Elevators-Building 2 40,06JUN07 01AUG07 �
_- � ------ - -�
2700 Elevators-Building 4 40 06JUN07 01AUG07
- - - ---
2710 Dry_in&Roofing Building 6 � 15 13JUN07 �03JUL07
2715 Doors&Windows-Building 6 � 5 20JUN07 ,26JUN07
I -- - - --__----- - -- _ -
2720 Dry-in&Roofing Building 5 15I,27JUN07 �18JUL07
3210�xteroFVe eerls&Fnishes BBu'��Idi9g6 _ 60 2�JUN07 '22AUG07 �
_ 27JUN07 19SEP07 �i
2725 �Doors&Windows-Builging 5 _ 7105JUL07 I 13JUL07
2890 Gyp,Tape&Finish-Building 2 40'i 1 J2 UL07 05SEP07 �'i
l __--- -- - ---
r"Horizontal Waterproofing
_ CMU Walls-Garage
� Foamfill to Subgrade
� Frame-Building 1
� -_ Frame-Building 3
�:Protection at Foam
�Rough Fire Sprinikler-Garage
�_Basecourse Fill on Foam
� ,Rough MEP&Fire Alarm Garage
i� - Dry-in&Roofing Building 1
�_'-°.- Dry-in&Roofing Building 3
�Framing-Building 2
��Framing-Building 4
!�Doors&Wlndows-Building 1
^ Doors&Windows-Building 3
� --'-Rough Fire Sprinkler&MEP Building 1
��+Rough Fire Sprinkler&MEP Building 3
�l Exterior Veneers&Finishes-Building 1
�� -_°=Exterior Veneers&Finishes-Building 3
�� Elevators-Building 1
� ` Elevators-Building 3
Dry-in&Roofing Building 2
Dry-in&Roofing Building 4
W i Frame-Building 5
�-Frame-Building 6
°'Doors&Windows-Building 2
�?Doors&Wlndows-Building 4
1��=�= Rough Fire Sprinkler&MEP Building 2
�Rough Fire Sprinkler&MEP Building 4
�� Exterior Veneers&Finishes-Building 2
��Exterior Veneers&Finishes-Building 4
�Gyp,Tape&Finish-Building 1
�°"' Gyp,Tape&Finish-Building 3
�In� __'Elevators-Building 2
��"'"�' Elevators-Building 4 I
� Dry-in&Roofing Building 6 I
�Doors&Windows-Building 6
T""!Dry-in&Roofing Building 5
�` �' Rough Fire Sprinkler&MEP Building 6
�T --Exterior Veneers&Finishes-Building 6
" Doors&Windows-Builging 5
Gyp,Tape&Finish-Building 2
2900 Gyp,Tape&Finish-Building 4 40 12JUL07 05SEP07
- -- -- __ - --- -
- . - -- -_ 9 --- � I16JUL07 07SEP07
2727 Rough Fire Sprmkler&MEP Bwlding 5 I 40 � _ _ ,
3220 Extenor Veneers&Fmishes-Bwldin 5 60116JUL07 �050CT07 _
2930 Int.Firnshes-Building 1 � 60 26JUL07 I 170CT07 '
2940 Int.Finishes-Building 3 � _ 60,26JUL07 I,170CT07 �
2730 I Elevators-Building 5 _ _ __� 60'',02AUG07 �240CT07 �I
2740 �Elevators-Building 6__ � 40 02AUG07 26SEP07
__ - - -- --
2910_ _ _ Gyp,Tape&Finish-Building 6 _ 40I 23AUG07 170CT07
2950 Int.Finishes-Building 2 ' 60�O6SEP07 28NOV07 _
2960 Int.Finishes-Building 4 �' 60 06SEP07 28NOV07
- —— -- -_
2920 Gyp,Tape&Finish-Building 5 50 10SEP07 I 16NOV07
---- - - — --- -
2970 Int.Finishes-Buiiding 6 60 180CT07 II 11JAN08 ,
- - - -- �
2990 MEP Trim-Building 1 _ 20�,iSOCT07 14NOV07
_ - , 9 - i !---
3000 MEP Trim-Buildin 3 20�180CT07 �I 14NOV07
3050 ,Final Clean&Punch-Building 1 1p I
------- - -- - -- ----- -
15NOV07 28NOV07 I
3060 Final Clean&Punch-Building 3 10 15NOV07 I 28NOV07 ��
-- - - - 1
2980 llnt.Finishes-Building 5 70 19NOV07 }26FEB08
_ - - -
3110 �Substantial Compietion Building 1 0 I 28NOV07
--, -
3120 'Substantial Completion-Building 3 O I 28NOV07 �
- - --- - _ -- - '
--- -
3010 �MEP Tnm-Building 2 20 29NOV07 27DEC07 �
3020 I MEP Trim-Building 4 20 29NOV07 �27DEC07
-- _ g - - _ ___ _ __
3080 I Final Clean&Punoh-Buddin 4 10'28DEC07 11JAN08
- - -
--
— ; —
l �28DEC07 11JAN08 J'
3130 Substantial Completion-Building 2 0 11JAN08
- - ---- - ---- - , _ __ -
3140 Substantial Completion-Building 4 0 11JAN08
-- , --------- - �- __ _ _
3030 MEP Trim-Bwlding 6 20�14JAN08 j08FEB08 �
-_ -- - - - - -- - ---
3090 Final Clean&Punch-Building 6 10 11 FEB08 �22FEB08 I
--_ - - - -- -- _ _
3150 Substantial Completion-Building 6 0 22FE608 ',
- � -- -- - — _ -
3040 I MEP Trim-Building 5 30 27FE608 ;08APR08
-- -- - - --- - _ _ --
3100 'Final Ctean&Punch-Building 5 15 09APR08 �i 29APR08
3160 Substantial Completion-Building 5 0 29APR08 L
HYDER!.
I�qNSfRU('9lON IN('.,
Gyp,Tape&Finish- Building 4
_ Rough Fire Sprinkler&MEP Building 5
- ���¢�� 'Exterior Veneers&Finishes-Buiiding 5
� - Int. Finishes-Building 1
��� Int. Finishes-Building 3
��-���-?Elevators-Building 5
�� ' Elevators-Building 6
�"�'°Gyp,Tape&Finish-Building 6
i Int. Finishes-Building 2
, i Int. Finishes-Building 4
�Gyp,Tape&Finish-Building 5
t� °• Int. Finishes-Building 6
� MEP Tnm-Building 1
�° " �MEP Trim-Building 3
`'Final Clean&Punch-Building 1
� 'Final Clean&Punch-Building 3
� � -'"_ Int. Finishes-Building 5
Substantial Completion-Building 1
Substantial Completion-Building 3
_ 'MEP Trim-Building 2
��_:_MEP Trim-Building 4
i Final Clean&Pundh-Building 2
!Final Clean&Punch-Building 4
Substantial Completion-Building 2
Substantial Completion-Building 4
° MEP Trim-Building 6
Final Clean&Punch-Building 6
Substantial Completion-Building 6
?'- _: _ MEP Trim-Building 5
Final Clean&Punch-Bu
Substantial Completion-
Date Revision
18JAN06 SUMMARY SCHEDULE
� 05MAY06 1 Revised Start
-- - --� ---- ---
12MAY06 Contract
Checked I Approved :
{ _ __ I
DHT I
-- � X *, i ' N��vnruc .. ,�s+"' _ � ,�` *' �
i �
` � %� � . J� �% � - � ... _ —__�- + i'. I` �'�� �`r .` � ` --
:`� �`� �� Y 7 r�wo ma.i,une.Hc.
' � � RiVA RIOGE � � �� `\CWRT�CONDEE NIUMS �-��-_�_ ������
. • \ / ; ) ... .. r��+-� ��� .� ��� 1°i j� /'��� � �' . 7 ' i� `
1 CHAliTS C � " -
� ' (NOf2TF± � ! � A PART OF I -- „ � 1 �. . � TR�CT G � t: � ��.�� u��.
OW PUCE I �� '; � � .�e _- ����-����� . . I 1 l0T C�OCK A '`� � � J/! 1 _ f �-s.F E2��+� .
�
� � L ..:. �� � 'y � �� 4 _ �. 1 /� S -� 'N
I CONDOM / ..� . �� � p# . �5 .-.\\\\�\\\\\ 'j � �.SIX1TN N7NG '��_---�--' LO C '� � S� O ,.,.5� \� '�RED LION COtJ005.- ��*��� ,c.f �--�
� � � � �� e� � ���� �� e 1 � l� � , +c��`�� � ��� � �� ���� ���� � �
�. I � .nc 1,.,- _.,..` x� � "Y � � �� �a �
� reva Ri� � (wu r�'-- � ----��-'� vv <��'' _ �� \ ..�
� � ja_° �CHA����fsouTr+%. .`z�.� �'. � � � '�� � . �� � �' ;` �� �ta•. ;� •,��;�w O
'� :F�,,, � t m-:.:: 4„- .. ; u. � _ ` 1 �i �� 'n � ``su - E + � ,�z
-- � � s "�s:w�.� � � � �-- � �8������A. ��,r�� � �' � �
� �E� ::. -- � . -� 1 � � � � � ,
�� 0,�� ,,:. ` __' � �:�" i �,,�!'e�_,� � 1 � � � m. ?'� - '�'P{�•f `I CHRI571ANA . �+
� ' � � i
, � _ '�� __` � _�\ � s �\ � � �-"C� o- _ ��;�e���-x `N.:. + 1 '� � -..�'u�z � /T, .+J_'_ ) .p � .4e �l \'��\ �. O
���� � - _ � "� ;J _ _.c-°�°--�;,�*.�w ' ° J � � ,_ �;:� � A. � i� ;��'� i •� `�?? i--i
� ,_ � h -� F�. ��. �.�^- � \-P� ,��/ f _�'�-�'"� �° � �' xs ` �\
, , ��
, > > _ _
,� . , _
%
'. '. l 1�' .,.�..
,` �
„ � ...y
� {^' �
. ' �.. , � .��� !."`�` ;. � ;\ \ - ' i /� .
��� _`.�` \ , ..._ � -,r...d - ..�'�� �#- / --��—��-`� _ �'i�. -',� . ��'°7 - i o,:� �'� :.- :� ��oi._. A� � �� � .
, .. , , �- -.. , \
i i
_,. —
. _ .
,I
_ � , °� ,� � �:, � m_ � �, � ls ! , ; ,:`°���.�.a� '� ' �� ?,� ,..,
, 1 ,
e::
� . . . — �,�
� _
:�
. �„ __ ._ _ ,.
�..
�
m
�
. _ — _ . .���-o�-, . .0 � �( . �� �
r � � � �' n Y �,.
�� — g' � ', h:.. .�' .� 1� �J .:6 '°"� �� 1�. . �' - r+'£� � �\
I` �
� �
� e
r
1
} /
I 1�- '�,. . "
�
� � :.
b l ��
f -'4�* .,.�.
� . �,; . �.M o,,.. . . �
� ' .
. ,� l
�
� -0 1
-���,., -:�. l
we F�"' t.
� �. ,.,.�€,eY� �.�� 3 �K� .?;;;`� �7•;�-L .. L�,SWTH;i°�S'MDOMINIUM'�"^',.��,� ;` ..,, li -�:� 1� , A ... �!r[,�� � IY �;_ ,.,\ �
^ � •,:'-tr -b..� .�.: '�k.,<�Z}cF .H i.- � �� � �', .. :. .Q _ � '.� . '�. i {• I \\
�� � �� � °Z.}� n 1 f - il . ��� �.
�� ,
�- \�. - _ _�- ,.G ' §.� �� r<-? .���� � (1 � � i.. f ;�0 � ��,..,4. �G`_ �:..-.� �GOLDEN PEAK HOUSE ,�� ���r'___
-------- ---�.--- _ . , -1� - - --A— �,- � - --
� --- --- -- --� � _._ _ '. i� � � �� '-� _
, �"
_ . _ �
_ , _� _ ., , . . = - - - �,
- - - M . - - -
�-� `� --.--�a«-+.z;. ,.. �.,r '"i'.�. ' -__ _ i�.._1'.3'� :.a. i �'a` � ..w+:��F" � ��L -
, _ �
,., . .r:r._.._ j .... �
` ..;, ��� _ ' "..,�....
�
��.` �� \.� o r � .,-.. .�� � .. � e. ' x,.,� '��'��-'°'�'�'t � .�� :l�,-� - "wH.�. i �'�� s'� _
__ � �, . ' -_ -' ,
� o �
f. ..� . , � . -�
\ ,
� . .
- \ �� `� g _.., .-��' �, ..i?-.:,w.,� �R- -� .. �` � .,w �`= _ �e4 I .'� � .p� �'. 'y.,_.�� � _ - -�r �\� \� I 1 i - -
I ��b' � . '� s ,� � �o { r � �� ` ' �
` � ` �� \\ I ` `�\4 �`� __ .��� y� ��'• � �`r�'`y�°'�-%i � .���.. ( ,� `�jn� �_;�,� ,z.��`, J� � __,J �� ` ` -_
�\ _
\
� � �` \ ...�-r - �-- �
� �` � . -- . ... "' t - - . �„ �:L
� \ . ;. , .. � . n �
��` `\ � � _ . -_ _,_� . � ., �k°L'. _ ��s sr.
��� ��� U. F.S. a � . . . '�` t� �� ' �f �� '���`� w
� ` ` �` _ . , .�: � ,y�. �, �ibi2' _ _ E �� �Y
m,�, - , ._ - , ..`
`\ \` `\ \ g"� � - __.�_to� � ,� ; ``�`. °' -;K �i�rsa�EK s�ew�� m:_-- ,�,.�� A q r,i
�
� '� F
� I _' Rl CREfI(-SU � Y�^ _ , `} ` '4C �� � 1 , ��.6sR
� � � � .
�
�� �� 1C ' .\ �. . T_ �
�� . .� � T--- ' -- -_ �1� � �'-. °' _ �,- - %, F ,� '
__ - _ / � �.� � �� � _ _ "1-c +" �r f1^1 `�'� =
\`� '- .- - � \� � :�' ' ,..�E� r' � ...,;s __ �� e,'*j
� �\ - ,_
. \ .. �� � "
� . � �
�� � � � .
�\. �` �\ ` � . , �\�\\� ` .� 2. ' _;.�s ,-^+ �.��� `•y,
\ �I� - - ---- � , \ � ' ' � ^ �� � � ' � ,.� �5 I g
� � � �
� �
� ___ _ ` " �l� _� ` ;\ .�,\, �,�;i \�..�" _ _�- , ��_ _"�=r '� . .aa`,`
. . � `\. .
. ` .� �
.
. .` ` � ,. . �. a
. � � �,.
.
.\ ` �` � �
�
i
i
� � �i� ' � L�" __°u' �W.
. .� . �
�, __ `e"- � ��-.. � �'.����� �a�_ ,.� _ _�.� _ "�"�"� �a-eee
. � � . „
. . �� �
�'
`�` �� � ^ .. _�:.- L ut � � �� � � � t"`
��� �, w� � .� ��� . . . '. -�� �� � � 1
� � ` �a
� � �� � ' �'' ,:��, , :� '4 ..^:€'-1' `�:��•. ��' r _ �.*�s. ��. OK t j,�'
\ .. °� � � _ . �_ .
._� � ___;, ._ , _�, .. -` ., ., '..•.*� v� -�
� •� - , - .�, � yi` ..�" ��� �` ,:9 s i�5 ���.
��\ � i �' �� {�� � _ � - - , �� �.rv , d� .� �'. �."�: � ; '��
\\• `;• � ` ` � � _ , -_ `� �� ..�` �� _ t� � �.' � � .,I I .,���`�� ;:
� `.
.� � -
� ` . . `.. .� � ` ' I
.� � � , , t
. �
^� � , '
x
` ��\ ..L _= .,y ..� ._�.,_,; ,�y�. . _ -� �\ . �X` ,� �� . �
\ ` _
\ �
. �\ �\ � �� J,�_ �.. .�`, NE%JS�lF-� t� ; � � .
�\ �\ "�� ''� _ -::> _� � -��'°'_ \ 1 F;�' �s�' . I; , - y��\f
������ ��---��/_" _ � - .�- �� `�: . �. � ��� � 1
� �,�y x
�\ �� ` ��-- .�� ,- __ ' �.�J{mcjv,c ' �- __ � � � �� .
� ` �` �._�� ` �\ " �� _.�-� 1 ;\�\� .... .. �' ' . S� \
\\ ♦ `♦ _ - ` ` ��\ .1. . \1_\ ..\� ` ` I!' ��
� . ;. ., `� � .,.�,�^ e, ' "'`
�, __ _ � ti - �-�� . , � ..... i rt-
. __ �� _ . . .. . `�� - -- . , �v�. ��.�.,�
��\��� �.��`^,,_ � a � \ .\ � �, ! ,.. i � �;
1� \ � `r � 4 ti i.� �r.,a" ,� ,`-_ r. �
� �� � �
�� � � � � - - � ' .
_ � � � � � �'� \,
GC OFFICE COMPOUND , ' ' � ` \\�,, �� -- � �„y K �\
PORT-O-JOHN \ .ssa ' � �,�\\ ��qo � i�:,� _ �.
.EGRESS STAIRS `�\ �` �`�\\\\���\ �� '. ��'b� � �, ^ ,�- y „
-�`MATERIAL DELIVERY,TURNAROUND,JOB ENTR,4NCE � \ � �`�� �.'',` ��� �*f'� ° ' 9 �'�,j �t �� i<" �`
�FLAGMEN-SEE TRAFFIC CONTROL PLAN ` \�`_\ \\��� \�� ��� � � �;;.: � 5 �'' s� �� � ���,,;� T' �
VAIL ASSOCIATION SKI COMPANY BARRIER ��� ���\ �\ � �'��,: � ��;zV� . - �- y, ��., ' jrn�i��„��,. ~
EMERGENCY DROP ZONE ``��`.\����. ����` \ �\ `\ \`\ � ; .a'`°� ` � :�'�_�l�°„'�, �� � "
�PROPOSED SHORING L�NE �-« ` \�� \�� �� �\ ��*�i.- �,���� ��"` I �����L �I �'
� � ������V� +.�k � � � °�` � ��
GC 8'PLYWOOD FENCE AT PUBLIC ACCESS � `�. � r 5 �� ' �;
GC SITE FENCE WITH WIND SCREEN \��� \\ \ ` � \��� �\ \ �:��r�� � 5
LARGE TOWER CR4NES :\` \�� \ �` y�� ; __ _��_��;�� � �.�
DUMPSTER N01E:'fQN DUITS A 6L` �� ` � � _ y.7
VAULiS E%IS.i.SEE �� � ' . � `���"� �� �i� ,M,,
s+4�ow u7i0W PLANS � �) � � �'�FSs �" 9a
LIMITED MATERIAL STAGING AREA `�`� �;,���� r ��\ ,_` �.,,g����,�, ��
. �
, HAUL ROUTE FOR EAST SITE SPRING 2007 \`�� ��� ��� �\� ��� _ � l; '�:� �'
, �r��.� _ ,�`.,,�,_
DELIVERY/EXCAVATION HAUL ROUTE FOR WEST SITE �`` � � \�\\`�. `� (� � ��"
TEMPORARY PEDESTRIAN FENCE ` � `� ��� \���\ ������ ` �-%„^°` -
� PEDESTRIAN CROSSWALK �� - -� ,,` � `�.\ `•.`\* ,�>�`�,�\ �� ` � ` \ �'� � �� `��T�_".
SIGNAGE \j���n ,J - `�` �� �c+ i 8?� �.�� i' 1 �
ag 1-NO BIKES BEYOND THIS POINT ,`�l"'----___`` ` \� �\`��` ��`.\`;� `+�` `����� ��
@§ 2-NO PEDESTRIAN ACCESS BEYOND THIS POINT -`-----____ � � �`�\` `J�� ,�`;`y;-, � 1�•
°Q 3-TEMPORARY CHAIN GATE `` w \ \ `
$ ::'<.4-CAUTION HEAW TRUCK TRAFFIC ON ROADWAY
$ �5-SLOWPEDESTRIANCROSSING VAIL FRONT DOOR
�' 6-NOACCESSBEYONDTHISPOINT PROPOSED ACCESS & STAGING
� �7-VAIL RESORT EMPLOYEES ONLY
•:�:��g-BIKE PATH CLOSED 5/22/06 - 10/31/06
� .9-DESCRIPTIVE MAP TO ROCK LEDGE ROAD
■10-PEDESTRIAN ACCESS TO VISTA BAHN SKI LIFT VIA
GORE CREEK DRIVE TO BRIDGE STREET
� C3.0 4.03.06.TIF(34%of Scale);Vail Front Door Logistics Spring 2006;Vail Front Door;05/17/2006 12:48 PM
A � �
---,� GE; �Fllll1G i � ---� `_ , l
� , . �� � . p.�,�
i % �� i � I �
�...fi� � `�i � 1 .
• I '
}'' � �' ♦ ��f j � \�
• '• 1�\�� �i � -_J �
a;�y�** � =�'��'`.\( i`'1\�-
r
� \ � �\ �i p� �a..
; ��:�� ,�, _
��••+• �ny f•�� � ' ��;�fri_ VAII.RPSORTS
� ���� �` :, DEVELOPMENT
1 !�l i�i COhiPANY
��i.. ' 1 ��J y nvoN.cmnanoo
�''�1 � � � `y ; ,1 � _ a2jao
r ���� ��/ �y aacNRecrur�
.�� __�.�/ , 7 d,.,� �
� r �° .. . _. _ �, ; ..��
/`� T
�', � LoT �,\t2� �°°°°°
� � .�, �--- ��� ,� �.,�
, , ,
LOT 4.BLOCI�i � �°""`�0.�.�
� ; �" �y „�
��'T � �� � PMOI�TNO&]391 �
� . � ''l..-��`�L.c+��L)L�� �ry0g OA'I�E �IION
F�� �F;�u �`� � 01 011006 W161MICIIR!
� ^(/ � � �� �{ 61E C/'/.61PoICIM.W
\ `�` 111� I �� FINRIRCGE33
� _ .'� .^J�y}"�_}..J.' 0e RNDSTAGING
Oj- �� 5:`— i/
� �� � ��-����� ..
.�� � - _ �, � F- i
�� �
�� I . � �-J= i
-..Q � ! i `.. ���-� .-a
-�� ��'
�`\ li / �� � .. . .- I
\� �\�vx���f�/� ����% � �
... ,:> , `i, ' �
� �-� � � .
�
�� i,
R-�:�. ��`�- ��./ � ��� '
� 4�_ °�$�, ; l.- o�� ;
� ` ._�"�,� ���' 1 � �. {i .�:.,
I q � �ti '�';
- -__.__ \�//(�•--� �/ `� * � 'K i
.� �------- � � � yl �O
I
srre
SI'I'E
GRAPHIC SCALE F.XISTING
" ° CONDIT'IONS
�a Rr� PLAN
I lrch �0 M1 �O�.O
cr°i.,. t•=�a'
�
`� O
� �
��
� �
_�
�
�
�
�
.
� .
o � �' `—� _�._. — ��i1Ml�~~'�'_' �— l ` \ �g,� � i1
/' �`.� --� -- -- _' I ! ,i- ,\ C k I,1
����� �-" � _t_ -='-w7",e�oac t � \dT 8.BL� \'` � �_ � ' S
����.,. � . . I y� �.ri \ �
�j;/ ' � I _ _ � �
� �\ L0T 4,BLOG(1 �� -- -t- \ ' .
x � ' � � F t� � �or e." �ocK i �
���� � -- _ r' t '\ s
�°— _ i �`r `�
�rr= �� il
� ', _� ,'�, / _i A . 1�-}"�"�'-�_ _ _
� � �% ' % 1/\ "
.\� ; , , , %,
� ' \..� \� `�� LAT Q(�BL�(1 � j
� '�� _�` � � I LOT .BLOCK 1
�: „� 7 i i �,
�s'� ` °.:-. 1 �� �� � � /
� ��;., a�� ��� . _ ;—r, i � / �l
� � �.
� �,�, �. � ��,;,_�=, ,1� �; _i , -:�� ,. -- ,
��, �, .= ,,__ � ✓�,
,� ''�; -___� _ -L------� ,
, , �-.—. �
; � ' � , .—
XF � � � ,:( /��LO�BC CK 1 / ��„I` " '�
� �r ` %n\i ;\\ ��' 1 '�1 LO
�� �� �� �lf � ��4 ,; 1 � �
`µ���� �\ 4, ;, ' \ \- '�i ;1 � �
``\\\����" - \'` i1 . �L T 15. `�
-'_ � \ 4 i
____.\ _`\ �,\ '1 ,
1
\ `,� '\ �
.�\
,� � �..
\ '\1, _,_
,-
� 6 ��� �""�
� r�.�i� �__
ey�O � �'��`�i' `'�t
see cormNU�non �:.�
ROPOSED HAUL RO \ \t
PEAK AR � �
1 �\
� � mr cc�(rn) �
�� e -,��
�
�
�
Np
Ce
R i
`
1
., .
�a,a�oac�
,1 .
i 11 .
_ � I
—"----- __ GqDEN PEAK SKI BASE I
� �
e,e�oac i _
! 'I ` �'��� ,__
�,1 "Au.�r�,y�
4�,
I 1
- -- -- __-�--� ' �
; - �
� +`/'t
l� r n.s�oac /
., ;- o -
� % cHi�,s c�,vt
�
\ . \ / _\ r
� � }y ,,.1
� ._. �p
T 16.BLOCK a � 9LT FENCE(TYP) I F�
� � � ���4�4 4 4�4��� � i � ��� � IMkdAwm AT�ANY AcCE55�EMRANfE
-`�� (� a 4 4 4 a 4 a � � r �. ;r��� 1HE si[.lui mur�c iuw�c nie sre
� /a E�,,,F y<' SIULL BE C7ED TIRWQi A SCE.
�4 a 4 ��c,�'� "1 1 ,�--
d a d a 4 Q d Q
9L7 Fi7lCE
O
�
s
C6.OB 4.3.06.TIF(34°/a of Scale);Vail Front Door Logistics East Haul Road;Vail Front Door;05/17/2006 12:36 PM
r
W
O
O^
^
�
� w
�
�`I\
I
� d t' \
ALT (TYP)� Q w.mm.wuu
d d VAII.RESORTS
/ Q 4 DEVEIAPMENT
/ d d COMPANY
/ a 4 nwN,cannnro C
/ a 4
a°a � -- --- a2jao
a a — u�a,rrFC,uaE
,� �..� �
a a� � �.W
a �
� reom��+o:a.w.i
��ue �xua
� NO. DATE DG9411PIiON
� O1 6t140A W15IRUCip11
/ am.ae ewc ovr aw/
/ rwi casr.
East Haul Route �
FLAGMEN - SEE TRAFFIC CONTROL PLAN #1
GC Site Fence
SIGNAGE
1 - CAUTION HEAVY TRUCK TRAFFIC ON ROADWAY
AS D SF
L EN SI(
.�.,e„ o o a
� � �e
s °
�
s�
EROSION AN]
SEDIMENT
CONTROL
PI.AN
CO6.B
� ,•-,��
� e. �, I . .. � n ' - NOIy1H 1HNG . . .q-'�%� � �
__ x ... . , . . . .. er� �Y � .. �.
� �+` ° i�"re; . ,". .
� {• �� `� I� �„' � -'=w
� RivA Rioce % ��� 4 � � � :-��'� 1� �� , . � � `� ��,' ',; r.�«�,.o�...vM.�.
�/ � /y _ � �.rr � -- ' � \COURT COND INIUMS ,
CHALE7S � �° 1 - ... _, 1 �� �/� 1 CT C ^'� � ��
i
� - . °- iNOR?H) +.'„ � f,.- . . �:. . � . LOT C BLOCK A� � ` � . � - t _ � E�'A ��.mm .a
OW PLACE � ' � ?�. � _ . /� �, ... � � -'� � � I � � �..� � � �� +�
� ' - - . / t� %v y��--°,y�' � .�.'���' ���` � /
�� �
_ / ?°.
♦
y �51��1 .:§WT+i WINC I � � J,�,.. 4 i . y �5 /�� � �%.� r'r
I CONDOAI �. 4 ! ; .�- q T I . .� LO C l �1�,� � '' \� RED LI(NJ CONDOS,. y d �v ,vf
� � :'�l. � � �, - t BS ND7f1EARE � � ��. 4, � �'
\ I � `'_�° �� r� � EENTNESOU L DGE �� . �'-� �� � _ �� �'^ ,yy � �� �I
I Z ��� ND T I L D T VAI� .. �J ��1. �-i3��6 � �� � A 1: F,L�
RIVh Rlor �� . O Ff ' - �' • �Z
..:.
� :, m... . . . �
:
��� r ��....... � CHAI.`__55.(�9UTµi.. u� "a r` ., f I 1 � . � 1 ,� ��A � � �� "� "���� T..,,... _ � � . �� � ''
`
,p
:�..
�� v � ,F d...f '_` 9. sam � � � a \.:LL,\ u + �♦ \ �� F �# O
�\ ' ��,, '� __ • : '� : r <{. str����„ :. - �� �__� 1 11�u� � ������ ``�' � ��_ Z�, ��•
� _
\ � 1 � '
� � ,: , . �
0,��'$� . � �t ,' � '.. �` ,♦�� Y; . 1 1 �; m _ T^ ' 4Q,P�c��i Y�� ..n.X��- � CHRIST7ANA �. O
�� � -- �- � ' n , � � . -„ ��_ _ � 'c t � �� }.
�;��� 'i '.:'.=3�""`� .w_ �� � � t.�T �� ) � �\, � "a'� A
'�t� , �, `>� � '�� si .�Pe_ '��p�'n�`°�� -�� � '"'' � �. ' ;°���°� �i�a '�_ �� ��c v ss C'� / �':A . �+ � �
'�������������� c.�a -- `�y�_ � - - \L 'g ,— r_� � . --������i'. , ,Ea'._,,` �..,'.`\ �?� �C �..
�_:�\ - � �'*.Y k� . � . '� ,k� . � " .p ., ,.�,.Li . -� ��� .�1t�' I a} i' / y{a � "�,�� /�
,
; � „
-' ,,;:� � ., < -r �i ,/
.
R
\
--'�.i, ���� ��' . � �:,.._ �,.. --- —a�_ .. -1" :�e� i� ..� ` a .. �^ i'�" ,: o� � � _ \ i�
� � '�b �� . . ., • / '
,, ,. � r rg., ,i --- i.:a°�; �1
&-. � '�� : �,�\ %
� �"�i �
! '� -, � .�: � _- � � . ., e � _.;� � > ¢ .� ��� �
_ � - , � l� ) � ,_�� k�a 1� n ���'` �
�` .;.. > .. � ._. .. , �..,� ,2 � � ��� � /
\ r . �s� l `�;� �..�,o � . I ,
������ , e , ;�' _ .+- i � �..:-aM� '' _ �s' ._ �C \ > V
_ "�,c s ji.t���!-,��r' + � �� � c... -}��f� k ?N` :��
n
�
<u�
� ri- &. �,.y° � /. -- WTH:e:�iNDOMINiUM ��� .�,a. �i r�� �. A� �� . x � � /
� �. �'=ar t. : :. . ���
, - �,�.� ,,a '�s�'F y �:, q ={^ ,�.�aaE,�s ""� a _ .,�.. �. �� •�, `.I F ,^ .�: ��� `
_ .,�, � `"�
, , � x
_ , . _
, �. : ,
A y F A \
�, `�� .--. .�. .,a � ``��� �� �: .�� /' . I� .` � -os'-` ,°"�}'� �GCIDENPEAN�HWSE '`�� ___ ____
I
a
���^'r
� '-„z'��
t
�
f'
� � � .:� . . . � __
.________ar`___�\__ =?i _; ___'-ca l:_.� � . ._.a -1 .��___ _ __ _ __ __ ___ __ '._ _ __ _ __ _l�_ �� -L07 C1 _ / .��
�
�
'�_� _ _. � �-< �_..�.�� '..'+-�,-.�...°:>�: _� �';c L�� �" '*.�� ,�'y T�_'�.�_� "'a. �ge '"�
. ;
+
>_�
�_ _ .. ._ - � - _ "�_�,��,,-�����—�
�
_ J
��� �\ � nr n ., -•� • . ,- � .. '. � . . . � , ��. ,y� �-_������� / .:`4 •� mK:"��"�`��_/ µ • '���( _
� ��
m� : � � ,q
-- � � �� w... ` -"., ' �� .. �,�� cs � -�� �� .�•. . ��\ ..�t .♦ u- l a r" c :.s.�` �,.-•---'�-,%�' �t � �'T`^�� �a e ' ,o�' j � '1 X /µ� .'- � 1
� � \ ' :,- • _ . ,� .. n., 6 y � �\ ' .,w� ay f � #!, � t './� - � 1 �
� � �� � �' f � _.__. � , . ��� « . � �.� � t M r�� � __�
�
��-.\ � � � �"'� r.� I��...:..�a4 � �.... , - o=�- 1 ,'�. �� t. t� '_ �A I , � _ �
� �.. .. ._ . .
'..
__ � — e -, . � -� �� :�' c
, �, , , _ � __
--_ . ..... _ -= , , ,� - � , _ X� --r L� ce; uap , ---
-_ . `. . _ _- _ . _ �� � � �°• �
,
� � � � - ..� . �,. -'v�. ' W =F �
� � _ � �.� .. _ �- �� .. `�
� � �
� - � ;; ' - ��v __ f _�7 �`�'��^� '�� . �� r� �� �� I F�
, �
-, �. �� � U. F.S. _ _- .. z R�.., .� _. � i- � ," ' '\ �
`� �� � � � ' � � ''n �>. 2 \��li��T�, _ k�.:" . ��G"`^- �no. - � � l ��� Q�
(. �
�` � _ /�
� �� � _-� ' �� �. AAILI: EK 900 �l �u.� �s. � � I�� �� /� '\ !
�� ��` ��` \�� �� � ''- ICL QtEf9(-Sll � � , yb:- � ,. � � _ -" _ � �'�? �s'�. m~w`��'°' � , � `�\i j� �1 _
� _ t _
�� � �-_�--_ ' ______-,- \'�� � '� �-' . ��� . ` ' ��-1`, .�,;. r i: +..,`� �,1 t ��� � i
, �♦ �� __. _ .`� _\ .. . ��� -�~ , '� r�... �..� .���� _ l\.� �,-___ l
� �� � �
�� -_ � i -- �� �� ��: ' �`� r'\, m� ..���� „� ,,a�,- r, ..� � ':I, ''i ,',*�,yi+*"�• :��Y� ( ���!�__'
` `� - � .�.`:�` ��`��: ?�:�-.+�.�` - - - T �.� � , � 1-�.� ������.o�.`
�` . \ ,,. ..r
'' \ ��``` --_- � ..�� �` ��``� ° . �>.i. � �r:�. �, . _ b� �.s, ���� � . '� �w
. `.
�,, . � - '
. . �� �' � `f
. �\ .
� , ��
�`�� \`�` � � �'- . .._ .�\ :� �1` �. __ -- __,.J_ e�i-�s �� i L! 'c'`i��� VAII.RFSORTS
.\ `. '� .. �w I' - �T` �'�,�- ,�, r� 1Li�. ' ..-.0 .� - — ��� �� vsi.o�NT
� �� . � � -.
. . ���� ,� �-- -� .x�- �[,� � i '� . _� - �,�ceas �ii DE
�
1
� � _, �
�-„ �_ /
� . ��, ���"� �t�c �...�_ - ' - - a 1 _ A OMP
�� � �'� ��� � v `-�.. � -�- �,�:. '�k` .. � '°'° ` �i� ���� �� - � �- 1 � �,���7 voN.cw�awo
.
� ,
. � � � �. .,,, . ,s � : �(° � _
� a�
� u . ,. �
� ia � s 5. � .` � � 2t �. ����a � .��� � I
�� � _ �x'��, � �.,�. .� e x � \ i \ '���
,�`a ..�, �L rP �',� ; �.� , � i �� i' ;r�� .f„\;;� _ o
.. � � ;
� °
` _
� i�
` . ` '\ . m ' ,�� .�
�` _ ,
. _
��. �` �'���. ' �= E � � ��.�� � �- -� � - � �\ d r ' � �g��' .� - � -f �i� - 42�40
� ...� , �--� _ �i 5� e r� i �: 2Y
�� . . t �"�" , �� -. �� � - � � '��- - i� V ' , f_�- 1�tLL e
� � � �y- � ' - -.. _ _ �. � , d..�..
`. �� �� `�� "�\ � �.,u � _ �/ a\�Z•�� „ �..-_ '. -- "'`� �`� � �L�p _� YF �*i./ } `)I 1 � ` �k� ;y9 \ FJ'• �.__—' - '
` - ..
. �}
I 1 ARCNfTECTUR
� � ♦ � 'b' .. �,.-��. __ *,' r Y� �
L � _ , •'� � ._^�$� � � I k � ' a.
� �`` ��c; , � �.__ _ \ i,'�'," ,.�`,.- �� . � I � ��;�}\ � _�-_��_ � � � m�..,�
���``�� � _�_ ""�-` ` � � .:- �'� �� �i . - I a o�.< 1� ;i �- � ��, r' ',
. � �` _
\ ` „
�\ \ '�'
� ` ,��
�\ .. � � - �^
` � r
� � • _ _.. � 5 `,i` -} =�-''�"-, >
\'� \��� �� \��` �-----__ ����c"�,���` - s§,.� =m��- _ �� __ �- 3� 31 �� 6 �1\ ���� I I .. .. ,� 7��. �oo
�� \ \�� '-. � � � \���✓-� F '":��...� � ��\ (. �� _, I�� �� . 1'� , +.+•`vRR� � J .T LOT 3f..9LOCK L �g �. p.,u�
�-.` ��`` �_-_` � � a � � _ .t. .�a'`'_��^v� ��\� �� ':,`"°...�.. � I -4.:{�-�� -s � ��; . '� 1 ,
y� `` .. � ` .\ .. „ k..a.. T�� �.... . . , I�_
�� - _ `\ � �J � . � � � � � f ����� � � � � ��` LOT 4. BLOCI�1 _ _" �,'S� ..a.ma.eo
�\ \\\� ___ �� ��.`\` �.- � ` .. � � �.� % '�= '� q �t. ,r�. �. L t`. _ �:ra + .,...._ � � i rv
�\ � ` �� �� ` \-� � ` .. ��\, � �\ Y�� �`A ��.'�` .. � �__ � ..�+I I � -'y�,. . (� �� e 'f�� eao7ec�NO.ews.i,.,�,.
� � ?, ,� .�k-� o- .,r-_..�� - ��s�� �B
` -"'- ��\\���\ �� \ .dtes ��-.�\ �' � \\ �����\� Hw�;,�;� a. .. ���"��y 4�,�`f - >. � ���., - No. nnre s�w�iorv
\`` ��� �\ ��� �� ��`\ ��� \ �\�. �,,`�,/ .. ��,,�'.� � �r _ � � � w oi.io.oe aa�xucnax
�__'---�`�� � �� ♦ ``� �� � �� ..\\ . , � ,^'�" `- � _ .'' '"` ..-!� i I/ ] / sq[ mwimenox
\``\ `� `\�� \ \�� \\`� � f � �II4 ��.. < \ �\\ � � / / � �.---- 05.0100 FINRLACCE55
�� �� � ` ``��� ` ���` � � � �� r� ` ;..I �� � � ,cT.� �'t.. � er�osrncn�c
\� � ��\ , � � � I � `� a� , "� -
�� ��\ -i �. tees..� \ � �� <� - .- r 1. I �, .. -�,; � aw., /
� �\ �� �` �. / \\ ♦ ti %�,`o �o� ` �-� -'x- ��i,�'.�. �l
� � � � `` \ � � �� 'Y bc\ � / —_ , 'Cf
-_ `` \` `\ ♦\ \` \\\ �, 4 ����� i 1 J '�'". O� I -- ` �.:
_� � �"� ```_` \�� �� w.w.� \\� \� \� �� - � � � T I I � n ..
� \ �\\ �\ �\\ �\ �\ �\ \\ �� T��ct:s,�, �`'� ����� �l� � b � , �� .
� � � � � \ \ � \ `\ . \ '� ._� ������_ �
� ��\\ �� \♦ �� ` � . �` \/ i t:� \ \
� � �� � �
� � ���\
�� �_I -•� � �\ � ��` \ �\ �� I `� ,'��� � ° �� ! 1 m _ , �. /
� \``\ `\ � �`'� \\ � �\ �\\ � � ^a:�"�A..1 �.. � '�r�. �,{'a°!: � } �� \\ I I .. � ��..ti 1
, \ � ` � � ` � . � �
� � � . ♦. . . . � �`� � � ��� . x q 1 � ����� 1 � � � f
�., •.. \NOTE \DUIlS !6. \♦ ♦ � \ � �-����i�`y�, ' .-t4i ' =�'e�•'�\ !�/ '
� VAULTS SEE � ♦ ♦ _ � ♦ W � .,� . �- �\ V/� b
GC OFFICE COMPOUND 0 IN snµ�o�w a�,ws. \ `�m� �\ -QS.�'s .- a�_3.. ," � n°:4� �,�xl` �„ /�/ ' ��r f�`rl- -_ �
PORT-O-JOHN 0 IN • � � ,�,,, �� � � �� ,.,�7�'„7�c �: ��.�,, ",>� ��ry�!- i��� �
. \� � ��.., . '�L' �...� ' i
■EGRESS 0 IN \�� \ \`� �'� \� � � '�`^ �`� �4 � / � i
MATERIAL DELIVERY,TURNAROUND,JOB ENTRANCE 0 IN �_� ` �� �� �.``\ \ \��\\¢\ � � `` ��� ±' `v ` '�.y` i ��\ 4I
�M FLAGMEN-SEE TRAFFIC CONTROL PLAN 0 IN _ � \\ ���\ \� � � � 'M.� \✓���`�. _e- '��,,� � ! '//
`� i ��,v����
VAIL ASSOCIATION SKI COMPANY BARRIER 0 LF �. � ,_ ___ '�� `\� ��� �y�'F. �, `�.� �' � �� �� ! � ���+��°;"�, � •��;1,\ i 1 �'^��'`r1{`,9
EMERGENCY DROP ZONE 0 IN '�� � � ���� �--_ �_ � ���
} -��y,1� �� `\� '\ ` `��'�.\\ �� ,'\ --� \ ��� { `:����on��
?- PROPOSED SHORING LINE 0 IN ' ,_ � -'--,` ��`\�` ��� �� � ` / �\�� � s� t" �� �
_ _ \�� `.!ti ������---- � °X:,
'-------- `< - u` �� � ----- � � \ � °�
GC PLYWOOD FENCE AT PUBLIC ACCESS 0 IN _ � , , � , �, / `. , � , W �:,' _ `�� -- � g
�GC SITE FENCE WITH WIND SCREEN 0 IN
�:-� LARGETOWERCRANES OIN VAIL FRONT DOOR S�
DUMPSTER O IN
LIMITEDMATERIALSTAGINGAREA OIN PROPOSED ACCESS & STAGING
� DELIVERY/EXCAVATION HAUL ROUTE FOR WEST SITE 0 IN 11/01/06 � 4/Z2/O7 S�
SIGNAGE O IN GRn2Hlc SCnLE EXISTING
.1-PEDESTRIAN ACCESS TO VISTA BAHN SKI LIFT VIA 0 IN CONDTTIONS
GORE CREEK DRIVE TO BRIDGE STREET 0 IN t a R*� P�N
t IeeA�M A
CO3.0
Cfelp. ,"=qp
C3.0 4.03.06.TIF(34%of Scale); Revised Vail Front Door Logistics Winter 2007;Vail Front Door;05/17/2006 12:52 PM
�
� �'� RIV14..RwE � ��� � '�'"�s+ �,y, .. / �. �� i 9v� �� ��,/ ��' � ,/� ��� �'��_
� �-,l�,:�TS�{SOUTN� � , '�✓-� a �� � l� ., � �� I t tl0M', � � A A /6 ��,�t"' �r«.a �n. • /
� � �'"' ,� � �./ � / � �F ' 1 ��� N . • ��Y� ENGINEERING INC.
� � a . 1� �� - � ��'- .�� " � � � '----� �' rr � ,/- ��`.. Q,O� � °"4�•1&m°
-- ,�` �.� �� � .���� �1 �' _ �"',� �'1 ��� /� _ "��_`- " Fi P�a � � ��`� ;�i
__ •• � f�� � �•~ �, i _ _---" �� �'��/� � �\\
` _
, . „"� � ' �/ o ��', ____'_ - _-- �a`� �,. , . \�
, � , �{ 1 • '
. \ 1
:��•w � ` _�: / � �� / \ � . � � ,, -- - . -- _—_ -_ " �''P .. . �` "1� �
� _ i �, ,�� , \ � � - /� J
-` \ _... . -, ., _ .,_ _ '�j"� /�/
, .._._ ��. .. -. --- j;_� , , �„ � '�, t`.A � � , ,��� A � V - � � --��� � �r'.�� �� �� . Z'�� �� � \
� ` \
�' _ �i� , -�� . . 8 _ � L� � " - � '✓' e � � �/ / \v I"'�
_ � 1�
. _ �
.�'7'e, v ,..,_ � _ . � ,.,� .� ./" "_�o-- __ � �sM„a�ns Co. � �� ,y'�
� `_�� �._'__' -�_..Lp ,d :�y^a i�,w'� �_- - - __ ._�� .t � ,`��\:�� . � �\ O
�- � � I O
_ _ _ _
�
� ' � � r` ���.
,
� �..-�
r � � .- ,
� •�� � ,��, �� � _ � � ��1 � r - ,�� ��� � I ��"
s.,..
�
� f� � � � �,��`�,C� � � � a �� �� '� '�`��'' -- -- �. . ��: i.,
, �. �,_ �,. . , " '°� �
�, � Y.. "��,.., � �,.j � . sw� -L� • ..�_ , .. .,� ,:. --�. .l ``� HILL «<.r= ... . . . i
.. , -�• 3aa.. �:y',�c.:�9� „`Eitf.. �1� 0 IN M,1:^'i ��& �-$F}II.DING �,,= ��
-� �� � bD E. ,TM.�� ... a.
- y,__ _ �,..-�5���l.e�. . . . . _ � � � � � •���i � �
�. � „��,,,_ - y �� `� � - ODGE A h,��- "��' _ . 1 t�� � � � GOLDEN PEAK NOUSE �
� �u;
� �
�
d� � � �
��
� -�„i . t.�. .� �r� �. .,-�� -- - --- ------ ' - -- -- -- ---- --- --- - - - -- - �p - -"_l07 C1 . . .i.
-� �� � �`.3 �� - - ��� _ �� - _ ��`�i� ��fl �?�...�� °� _,�, � �� '"����,
�pj. -ax. y ,y�'s�' i. i',� �" . „ �� . _ - 1 '_:: `.,�"w��7 .;sar' ��:u,� d- � _ �K. '.
-� - Jc _1= . �. - ^'��y..� . i'!E's"'��,,�f�z;� � _�-.�_._ v�- f �J-., y�;/ �.
.
,. .
, � ,. '
. ! .
_ .' L -�---w---- ��.� s�� T_ . . � >..rt .: _ r ���,�- .. , �,�� P�� _ `98` .'J
s:. «
. ..
__ � ., .;
. 't �y �7�' �., J � �l
r:.,.. � �i�, '�BNf �e� .A. :_� � Y J .�' �✓ � ,�� .� b, ___ ' r7__i /� ;s' �„ ��� k� iRACT,�'.
«dn. � . . . �, r
. `,
���,� ,.
� �µ ��
� .
.a �,�. , ..;' .-� � .. .
a ---- ��`
�� � .zs -�v� - 21� '. �.� -"'a_°=.,�L\�'��.<� •, ` ' � �..- _ �,- t�`".�d ����'�.�,i � _�. e.� _ __.�a�, �AIL� GE,flFldl
'
_
�
.....,,W.- ,.r .,. , � ,:.: r-. �e - �^:- , � =:�ck,�aii :�.,� a" `"`��fi}t ��-S
.. > _ � - "`"�„.. ' `�F , ." ... �����,� � � - � \ �r.M��tu•w. }''.*�� 3a �'(;* ��^ 'r'7i -11i _, . �' `���,
. �.
' . ` .-0 .� . , , . ..ti� � - � ��i✓� ,.�' �; '00
_
. '� � ' �,�� �
�
.. .__� . ��--.:� � .... �.��._.� *� � �/�
..i ---° � ,.�..t,.,, �a. a �;� ,., , . �.....�,,,,_=°�--.n�..,�...� .,, ..:. ,:,.. ��. ..._� .�.. �re J_,..-,c � `:i."��;,m �T;e '��._ � V J
�� � j .� �� � \
� � ,�; � a, 'K-� �,,...,..
_ _ � � ; , - ____�_,, „�.. ,�>_ F r _�.� ; `�i �
�,
:o�.�n,�. = c��: r -__ � e, _ �
' � -- �' ��a.,w.e,� '-` �` �.'�,eri s . .::� w-�.� �,� �� �-.�c-.� _ _ :�`�1
. t .� ..... "
� - `-. - �,. ;�, _.� . �+ ,. �� _ ♦
_ , ,,,�.+-�1A
� � ��
e _ ,; ..�. ,; u �, .. . ;, � �,_� _ =A :� ``"� _ o ,• �
.
,
; , ��A � . �� � .,, � � _ . � _
< .
. _ . �
� :` r,;
__ G z� / --
__ . , ,
_.`
_ j
--- , • -
--= � , ,
�� :�. ,. �.v. �\, Y -, ' �� ==�,� 1'i '��y �j- • +'
� � ,
� r
�
' Yi S - ' ��`r .' , -��—�i'.. �'. , .. _ �L_. �T '� � .. 11 '�Si
�- - �_ �_,�� r��.� , � , ���., H
� � . �
, ,
� � ' , ��- , - r -- , � r
,.� a
_ e�'� ,' �' �1 w;, �� �,,� �. � _ " ,.;_'_'� � � , , �� ` ���� �" ����� ,. ;-- ' �� � ���-�i��**�o�� _ ---
. i:: .. x � � .,."�.,. �� � ..� �� �° � -w art-n.,.> �.. .._ �
• Nr .; '� / py.�
�� �M� �� N°" �° �.. �ur�n. � �r // _ :"1^ I �fl�� f 1F�1
- � .d». � __ _ a � , �� � �l ,�
__ a �,�b� �
`� _ -
�
-- � �>�„n,. ��m i .yy�v . wP. .W yy� / //if�., _
` „� , „o.-..*� �..m,,,""�. , . .�..�s��„ tiV �t ��'''� � f � � -�a i
. _
,
,
� ^ . `
�
i
.
�. . . . � � � � � _-
,,� „ ,�,.. , ,. �� �� � �
i
y t I s�; � . .<� :��: '` .,:? �, j� �,., , .
� �
�� � .__- �.: . �:: ,:�� �� � ,. a.ai:
_"- -- .. �,y„. , ...,� r � b , .. .. � . ._ ; _-c .. � �.f°� �' _ �
: ��
�,�c � '. ":,. � �,r��W„,. .A� ^ �y��,. ;'. ,a 9`' 'a�� � �d" "`w�^ .��"'�� :,� r.c . " k`�. rw ,/ ��:�� � � yl� I' '� ..�� ��w
�.__- „� i _ i
�-°� � _ . �___.-__
. �
�, >
�.:
- ,no.r�+ . . , .,.,. ., %�"""e"° .. ,. �g, �`� \ , � ��r'�z;�'`yr%`� s,.. . (�au.�� F A I I .'� DEVELOPMENT
_ _
,_ � �,... „< �� - ., a _ ,.. , f� .
„_ * j�.:� , � � ,� �.�I� - � �
_" , � _ ` -' '� y� —- V � � .- � COMPANY
. .. - ,.... ` ..a.- � ;. _..�
•Y
�. � � _��.':�� � .._ "� '•,' . .: � ;. -' � . ts ' %:�l0T 1, B�OCK t�t,� � nvoa.crnnw�o
�
r
.
• �, • _
� �- ... ,. .�� . . . . . �.... . ., '
.' ___ . ._-'° � -:�� , . <.. �. ..._ ,� .,. __ ..;r� - J�� )
, - .., � ....... ���. ,Y\ ,�,,.
_
,. � .
�
..,_.. _...,. �;r �. ; .. ._ _ _� .. , - -- ��; a - - '
� ✓
r
�
� >, `, �i�� , .,. �\\-,. -�
j . ;.
_ , � ���� �� a� � " '� � e�
� _ �,,.
„
;. ..._--a_._,.:... . \ _ - ww -, /�"�--
; �
�
,
I "
`�-� `�`i"� 1
t
�r-- ,_ �.�, � � -- � �_ ��. �o �'� -- �
�
;. � �-i� �� � �� �' .-= � ��;- �� - - _ � - - - ' .,��. 2�4
� r i.
.
_ .
� , ; ; ,. � .. _ _ ,
. .,. _._ . ..
....
.�� _� .� `Sie3 ` a_' ' '__ '�_ _._ , -, ' j� . . j 1 j , ,-
..
.
. .�\. � c _ s .
�,
., .. , , _ ' " . �.o.,�
� .
� " �.� """"- '' • '
, . - ���� .� . ' ' .,�<- -�' ` . '.�' i7
� �., . � . . ., _� . �
,... .. ... , . _� . ,` � `
�
_ ,�y
...:.
„ .i,;=,,,.. ' ..,� _. . "",..,�_'-- ..___ -.. ,, ,, .�,-� .,..� ..;.,' u.� , �, I \ / °Y
� �- , -. oo� - ....,. � _ S R �`\
�'.,,. �. , _ ._ . f . �.00
e,
.
-_` «�
'. ' -t� ; c.:.:.. ,,, .. '_ _-..,- '__'__ B1 , .� . . ..� .��,:� .. ., c �
r . 's: � NxCNrtECTURE
� � �
� / i
;� � ��C�� � �^ � 1``� t '�%
.
- �.. � . -.. � '�' '7..., .� _ , g ��.
1
.. ,
�.
�w . '..-�:� . '.,,. . � .. '- . � y� i -�
` '..--_� _ , . '. -___ _l �� '•'/ mn.vo
� . . _
. --... ` . � . .._ ._ _.'
.
.. �_ \ ,... ,:. ..,..,r. :;i, .:-__ ..;-i . ��� .
` °.
� \�� ,��� �� n �� � � 1
�'
�-�� �p � .. .- . .-. __ ��+e 1"�""^c...
„ \ �� _ ' _
�- -- � �. � a .c� �.o�
� , ��,,�y�,�
�c`. -\ ._.._, '���. 1:._....:.e.\a�_..-..:�� .__ �-... ��::_., �.._ � '. ' z ._._ �y -'""�%A"p'c � � // '
y. ' . �°� _' __ '_ ��_ � u�� ' :'gH'�" �l % „�,.i .� �i 1``� ` / �j�
.� - -. _ �
�-'�7_.�__ � � '.. ,-'_d _ __ —' __—"_ ' .
,,--- .. �i u� - — -- �- -- ' ,'„+--�� r ' �'� '�� � / �' _ . m�
s .
_ ,
-. �. -- �,.. ., �.. : .
.�
�..
. ,.
�
. �� . _ -- __ i
'
. .,+� U S.F S � ��� _ _ ' � . ow.�a�,
.
. \�
. ., . . ._ , ..-.
x`
�. � `Y � . � ' �`�. xaa ��m - i� . --
,.,�
1
� ; ,�
�, , �_
. � �
, , 4
, , �
. ._ .,, � �- � / , , ,�
,, ., ,
,
. . __ . _ . / , \
, , - ,. -- , , � �.,��
�. , . , , _ -- _ ,. y
. . y //. _/�'
� �� ``` \`��� ,iK � � ♦ ,. �� � `�� � ��.�\� !y' 'S n' / ✓� � PROJFGTNO8�2591*
� . �� � ^�y L_�
�� \ �� � �����.`. i . .��� � I . . IS51'.E SSIIE 65UE
� �` � � _ w
�, � ��`` ��`y`
- _ \°�k� \ ✓ �I_ �, � ���. f`°O1� •/ � NO. DA'IE DES�ISLON
/
' � �' � ' LOT LO
�. �. �.. `. .. `�� ___ \ �.�� - . . �� m m.ions miannr,mx
., ., �, ��- _ r
,. .. -, ��.. ��..., '-. ,y `� � � �
, . .. _ �?.
`` ```` `^`` ```\ ```` ``\` � ... :�h'�\ �`�� � 1�� �', w.w•c.... .� 05.04.08 FINAL RCCESS
..� ...,., = \ `
\,... ..�,�`
�� � � � � \ _` `` ��, "';.. _ __ '
�� � � . � �`+ .
'� �.\ ��` ��.. `"\ ��. ���. � �^.. `.�� \ �. ��\` ,� �\ ANOBT�GING
� •, l I `• �,'%,
� /
♦ . `
. � �
� / .. 1 T U j
. . ,, � . .. ;;. ,:. �d 1'.
. . . . _ . � - - ���
�
� , . �. , �, , , � �� z, �
� . . � _ � � �
. . . '� �, �� � t a. � ��' �.,R � ; !� 'j ,y;�� �
.� �.� ^° � ���� -;��.,, � `�� �;, � �r, `��� . ��-�;.� I I' 1. I��'_
� - , �� , . . .���,_ � � ���� � � � � �� ' ��� �,
. �� � � �� ° �r I � ,� 1� -',
. �, � ,� : ,� ' � � _ ; � '� ,,
i ��i
'- ' ` � '�.� �
��.
, - � -
DELIVERY/EXCAVATION HAUL ROUTE FOR WEST SITE 0 IN ��,�,,1} � �' �,�� :�..�.n. ` ��\ \ �. . ,
. , ` �� ` �� i r� \ ,
LARGE TOWER CRANE 0 IN / �F Pp Ti `�- - � �k !� ' �_ �
GC OFFICE COMPOUND 0 IN " � . . ��j�� � � �1�'� '��
PORT-O-JOHN 0 IN ` � \ `\ �` \ ` \� \ +-J ' ; � � ,,.
PHASE 1 PEDESTRIAN DECK PAVMG 5/16/07-7/10/07 0 IN `� , �� �`� � I, �� ``^` Y� � �-y'�
`:i
MATERIAL DELIVERY,TURNAROUND,JOB ENTRANCE 0 IN ��` ,��, N ?'� "��
�FLAGMEN-SEE TRAFFIC CONTROL PLAN 0 IN '�, `\� \"` � �� ��`� � ��
VAIL ASSOCIATION SKI COMPANY BARRIER 0 IN ��� ��' � ���� �:� _ ��\ ' ��;,� !' � � �r
\ J \ k i r
PRIVATERESIDENTIALACCESSAVAILABLEAPPROXB/1/07 OIN ` `\``� `\� -- - -- =*�-�-_]- - -- =�; `�.. � '"� � . _ � �? -
GC SITE FENCE WITH WIND SCREEN 0 IN �`�`` �.�` `\���.�\ U.S.F.S. 1� _ _ _ `. �_ � ".�„� � ���; �^
� ��,` ? .'�� I �.�',
GC PLYWOOD FENCE AT PUBLIC ACCESS 0 IN �� �'�, ``\�� I �` , � �� '�; � �I
DUMPSTER OIN ��=\� `�� � '�.' - �-, - -__
_;HAUL ROUTE FOR EAST SITE SPRING 2007 0 IN 1` ` `�` `�� � ��'- ` �```������ --�_ - �. srre
7�. HIKERS DECEN9lp�G FROM THEB ����� �.
PHASE 2 PEDESTRIAN DECK PAVING 7/11/07-8/31/07 0 W \ � ` `�'�.�`` .�PICKER TRAIL WILL�EYl6O1RECTIED�e, �� �`� �
"�«PHASE 3 PEDESTRIAN DECK PAVING 9/1/07-10/31l07 0 IN -_ _ , bDM!!(ROCK LEDGE ROAD " - �� �
SIGNAGE 0 IN Il ' . • . . ' -'� . `'' _ �7yi�;; SITE
�1-PEDESTRIAN ACCESS TO VISTA BAHN SKI LIFT VIA 0 W ��=;�'��� _._
7M1
OVE T.i.
GORE CREEK DRIVE TO BRIDGE STREET 0 IN - `���k`�- G R A D I N G
VAIL FRONT DOOR ��� - � �ti- �- P�
Proposed Access & Staging - � � � - -- - -- -- C09.0
4/23/07 - 10/31/07 � �•_�
FILE018.TIF(34%of Scale);Vail Front Door Logistics Spring 2007;Vail Front Door;05/17/2006 12:56 PM
r
a
Vail, Colorado
Denver, Colorado
Frisco, Colorado
�
Monroe 8� Newell
Engineers, Inc.
September 27,2006
4240 Architecture
1621 Eighteenth Street, Suite 200
Denver,CO 80202
Attn: Randy Hart
Re: Vail's Front Door(M&N#5500.02)Building A and Site
BUII.DING PERMIT#:B06-0018 �.�,�� _ ���
Dear Mr.Hart:
The following are our responses to the structural portions of The Town of Vail Building
Department comments for the above building,dated August 22,2006.We have included the
original comment with each response. Our September 27, 2006 responses are noted with"M&N
Response(9/27/06)"and are shown in red.
BUILDING DEPARTMENT COMMENTS:
ASI A-001, dated 6/15/06: Parking garage entry way modifications
5. S109: Plan view at new lid modifications over new ramp below: Verify
superimposed dead foading is sufficient in this area, structural cafculations have
not been submitted and loads can not be verified. Section 3 &4/A203 show several
feet of soil overtop, along with planter/site walls, topping slabs throughout, and
the concrete and CMU shaft wall around the exhaust shaft. lBC 1604.4.
HES 9/18/06: Dead loads appear too low: ca�ulations show 250 psf dead bad.This
load accounts for 8"slab plus 4"topping, plus 10"of 120 pcf soil. Section 3/A203
shows that 8"soil is the minimum depth,additional dead loads due to greater soil
depth,sidewalks and planter walls appear omittect.Additionally, it is unclear if post
tensioned beam seif weight is included. PT beam calcuiations have bwe�prestress
for PB13(482k in calcs vs.589k on S003)and higher prestress for PB15(295k in
calcs vs.214k on S003), please check designs.
:
�
��.'?._�a�
.,...
�
2006 Platinum Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
C303) 623-4927 • FAX <303) 623-6602 . email: denver�monroe-newell.com
M&N Response (9/27/06)
The computer model accounts for the self weight of the 8" thick concrete slab.
The remaining 100 psf of dead foad accounts for the possible additional soil, the
sidewalks, and the planter walls.
The self weight of the post-tensioned beam is accounted for and included in the
computer model.
Refer to the attached SSK-A033 for the revised "Post-Tensioned Beam
Schedule" from sheet S003 with the corrected "effective forces" and "bottom of
concrete to cgs" for Beams PB13 and PB15.
No revisions are required to the designs.
10. 16/S303: steel columns are not called out on plan, verify small shed roof snow
loads have been considered in the design of columns, header, and supporting slab
and other structure below. tBC 1604.4, 1603.1
HES 9/18/06: Roof point�ads are not shown in PT beam calculatior�s,please verify
this loading is included as indicated. EOR coordinate column call out, not shown on
plan or section.
M&N Response (9/27/06)
Refer to the attached revised PT calculations for Beam PB13 with the point
loads from the up columns. The columns are noted as "by others". Monroe &
Newell Engineers, Inc. and Hyder Construction will coordinate with the Engineer
of Reco�d for the South Lodge Tower Project.
End of Comment Responses.
If you have any questions or comments,please catl our office.
Very truly yours,
���uur�rrrr;..
M , ��i�L ENGINEERS,INC.
.
2, ,�`•.
s :
1 �
� :
:'��s .:
Pe� •�:
.�
Prmctp�'�F�C •...••
d � �
� N �
� �,
� O �
o �.
d �
� �
o �
�� � � ��
� � �e �:o
° n o �. orc� �-�r
� o �
o� � � ��
� O
`� O
n
0
�
D
o m �
n r+�j Z
�� � �
z�oinm
�Z
����� Z
[mmmm O
c�zoacn �
r• �O(AO
=�ND� �
V � ✓�
�O
O p
°'� a
0
�
�
0
ASI A 001
�
ASI A-001
PBI2
�
PB13
—
��
PB15
�4"
�4"
�4"
—
��.
�..
28"
—
�8"
�,.
40�IG
�,�
48�iG
—
�G51G
—
�68K
18" e
Iq" LEFT (WEST)
14" RI6HT (EAST)
�m��� ��``"�°
���
I�I" LEFT (WEST)
I'1° RI6HT (EAST)
SSK A-033
�'� i�T � � � �OST T � l�ls � 0i�1 � 1�
� � �1`� SC � � l� l� � �
/5��3 � � DC�_ ' � '
A-033 3��
� 18
�
�� 18
Vail, Colorado
Denver, Colorado
Frisco, Colorado
Monroe 8� Newell
Engineers, Inc.
STRUCTURAL ENGINEERING CALCULATIONS
(Supplemental) �
For:
Vail's Front Door
Building "A" Garage / Site
Building Permit #B06-0018
(responding to ASI A-001)
Vail, Colorado
M&N #5500.02
```,,����a���au.��':
��� � �;;
s �
_
z =
�` :
'�.7 ti+;.""�PO.
�e
y�'�i F Cd►-d�'.
�:��iin�. .�
These drawings and calculations are the property of Monroe&Newell Engineers,Inc. Any use or
reproductions of these calculations without the expressed written permission of Monroe&Newell
Engineers,Inc.is strictly prohibited.
**P.E. stamp on sheet applies to the following calculation pages and indicates that have been reviewed.
This includes all sheets attached to this cover.
September 27, 2006
. �
:-•::.:•
2006 Plati Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
<303) 623-4927 • FAX (303) 623-6602 . email: denver�monroe-newell.com
-T-�-��'t � �o
Vails Front Door
Project #5500.02
Post-Tensioned Beam PB13
�
� �
�, ,
���
�
�� � .
.�. � �
,
Peter's Beam PB13-Point Load Roof.cpt
9/26/2006
Monroe and Newell Engineers,Inc.
RAM Concept m 2008 Bentley Systems,Inc.
RAM Concept°is a trademark of Bentley Systems,Inc.
2.02
'OR SiZE.
E
GONSTRUGTION
JOINT
INDIGATES FAGE OF I
EXISTIN6 LODGE
TOWER BUILDIDI� i
aiar-a in• I
eo�rror+ar i•-o•
PARALLEL 70 BE
TOP OF GONGRE'
ELEVATION � 8L
0
r---"' -\ ' '_'
b'WIDE GONGRETE /� i i P I
GURB WITH +5 HORI2. � AOII ^` �� 8180'-'1� � i
AND K4 X DOWEL � AOtI � i i TOP OF�� �
AT I'-b" J9� j� I I � GONGRE i
q• �� .'��`� �' 1�' 3p �
8 1 8 1'-4 I/2' � -.n�O�V. _�__���F�,,1i BO�EM OF A(3EAM �
BqE i
RE.ARGH FpR ���b� - ��' Ib AS REQUtf2ED �
�• .
OPENIN6 LOGATION �
' i i � ___ __PBI3_�
'�••-�" '�"' �V� "' -�"�-'��'��'
UP ONLY BY �� �
_i i . --
i
OTHERS - _""_'IS_ -- �"'i"_"."--"'_"__"_' �
8181'-4 1/2' i___ r�_ / b180•_�"
�i
I _I I . �
8181'-8 I/2' /� A51 A-001 i ppINT
L
A017 _ ��
TOP OF EXISTIN6 ----------� ��
- ' r�'__---".'r'.;-"""--"_'_""_ '
CANGRETE S�AB _�� � � --
.. __'--°--_ _'_ L�___'_ t-'-�--'__---°�_�___ '
ON STEEL.IOISTS -' i i
� JOINT � i i PB14 \
PIGAU `
.
AOI"1 � I I/ PBI4 \.
� �������������� � ��_�.����������
y�'r"-----°�i�-�-'-� '
8181'-4 I/�' �� � —-
_ ���__����� � w�.�_�_������L�������������������� '
� II
� ii
/ �� \\
8181'-4 I/�' � /� .i i
� Apl7 � � i� PBI4
�
�� ��-- ��-��'��"���--°����"�'�-��'����
/`2 4 �� '
-'-"-"'
ii —-
' " ' 'r�"'----""--°---_-'__°------�- �
B13-SP N 1 i i
� A51 A-001 i� �
8181'-3" i I i i 19
I � , 8181'-4 I�' �I A51 A-001 (
i ii
���T� ��_���______�� �_��� ���� _ _ _
� __ �_�___������_�1 � ��� �JJ�A��__�_ 1 i
i � 7_�__
- -�— �— — —_'_B2l__' � ----� tJ' - - � ----
� r---_' '__ -_'___------' I_ -____'__ __ --_'_ ___ __'___._ _
- �'�'
.__-- ---y-_-_�____J_-_-___r_� 8i8P_3. 8i80'-i0
T i GONSTRUGTI
I � JOINT I LOW POINT ,
SLOPE � _/_\___}_________'__"___������-� �'_�'�'
r------ -----°
18 I 1 � � J 1\ � �
`------ -'-'�'�� "-'-'--'-���J
� 4�-6� L`
�L `� `
�q._Z.
28'_�•
i
18
1
4
S�0
� �
�,�
�
ZIJ
��_
F�F
��Q
❑�
❑
�
�
8181._3`
'�-�---� -°---,�_�--
' __ ______________
� i
i �
�
� i SL� OPE
1 �
, � 1
Iry� I
�m 1
1 �
� �
� i
i � I
�,,,�,.�, �,�ar � Q ��
�.�,�___ r...,� 1��+►�
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
UnItS
Geometry Units
Plan Dimensions:feet Slab Thickness:inches Support Dimensions:inches
Angles:degrees Elevations:inches Support Height:feet
Loading and Reaction Units
Point Force:Kips Line Force:kips/ft Area Force:psf
-Report As Zero:0 Kips -Report As Zero:0 kips/ft -Report As Zero:0 psf
Point Moment:kip-ft Line Moment:pounds Area Moment:#/foot
-Report As Zero:0 kip-ft -Report As Zero:0 pounds -Report As Zero:0#/foot
Spring and Stiffness Units
Point Force Spring:kips/in Line Force Spring:ksi Area Force Spring:pci
Point Moment Spring:k-ft/° Line Moment Spring:k/4 Area Moment Spring:k/ftg
Slab Analysis Units
Force:Kips Moment:kip-ft Concrete Stress:psi
-Report As Zero:0 Kips -Report As Zero:0 kip-ft -Report As Zero:0 psi
Force Per�dth:kips/ft Moment Per Width:Kips Deflection:inches
-Report As Zero:0 kips/ft -Report As Zero:0 Kips -Report As Zero:0 inches
Materials Units
Concrete Volume:cu.yds Reinforcing Area:sq.in. PT Force:Kips
Rebar Weight:tons Tendon Profile:inches Reinforcing Stress:ksi
PT Weight:pounds Cover:inches
Miscellaneous Units
Floor Area:sq.ft. Density:pcf Elongations:inches
Tendon Ang�es(for friction):radians
Units-2
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Signs
Positive Loads
—� � � �
Positive Analysis
� �
� � � ....
� �� ,� �... . ..�
'�� 'F' rf.... ..�f�
.
:r
�...........r
r...� �-..
�
� � �� � �
.�, � ��...�� ,.
�, ti, ��
ti, •ti ��
ti, •��
~'�
Positive Reactions
�
� � � � �
��
Signs-3
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials
Concrete Mix
Ma Density fci Pc fcui fcu Poissons User Ec/ User Ec
Name (pct) (psi) (psi) (psi) (psi) Rat/o Ec Ca/c (psll (Rsil
3000 psi 150 3000 3000 3725 3725 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
4000 psi 150 3000 4000 3725 4975 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
5000 psi 150 3000 5000 3725 6399 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
6000 psi 150 3000 6000 3725 7450 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
PT Systems
System Aps Eps fse fpy fpu Duct Width Strdnds Min Radius
Name Type (sq.in.) (ks!) (ksi) (ksJ) (ksi) (fnches) Pe�Duct (feet)
'/z"Unbonded unbonded 0.153 28000 175 243 270 0.5 1 6
'/�"Bonded bonded 0.153 28000 160 243 270 3 4 6
0.6"Unbonded unbonded 0.217 28000 175 243 270 0.6 1 8
0.6"Bonded bonded 0.217 28000 160 243 270 4 4 8
PT Stressing Parameters
System Jacking Stiess Seating Loss Anchor Wobb/e Frictlon Angu/ar Frict/on Lon�Teim Losses
Name (ksi) (inches) Fiiction (fil�eet) (>/rad/ansJ (ksf)
'/z'Unbonded 216 0.25 0 0.0014 0.07 22
'/�"Bo�ded 216 0.25 0.02 0.001 0.2 22
0.6"Unbonded 216 0.25 0 0.0014 0.07 22
0.6"Bonded 216 0.25 0.02 0.001 0.2 22
Reinforcing Bars
Bar As ES Fy
Name (ks!) (ks!) (ksl)
#3 0.11 29000 60
#4 0.2 29000 60
#5 0.31 29000 60
#6 0.44 29000 60
#7 0.6 29000 60
#8 0.79 29000 60
#9 1 29000 60
#10 1.27 29000 60
#11 1.56 29000 60
Materials-4
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials (2)
SSR Systems
StudA�a HeadA�a Min C/earHead Specified Stud Fy Stud Spacing Rounding Min Studs
SSR System Name (sq.In.) (sq.In.) Spacing(inches) Spacing(inches) (ks!) /nc�ement (inches) Per Rai/
3/8"SSR 0.11 1.11 0.5 None 50 0.25 2
1/2"SSR 0.196 1.96 0.5 None 50 0.25 2
5/8"SSR 0.307 3.07 0.5 None 50 0.25 2
3/4"SSR 0.442 4.42 0.5 None 50 0.25 2
Materials-5
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Loadings
Loadfng Name Type Ana/ysis On-Pattem Factor Oif-Pattem Factvr
Self-Dead Loading Self-Weight Normal 1 1
Balance Loading Balance Normal 1 1
Hyperstatic Loading Hyperstatic Hyperstatic 1 1
Temporary Construction(At Stressing)LoadilA,q�essing Dead Normal 1 1
Other Dead Loading Dead Normal 1 1
Live(Reducible)Loading Live(Reducible) Normal 1 0
Live(Unreducible)Loading Live(Unreducible) Normai 1 0
Live(Storage)Loading Live(Storage) Normal 1 0
Live(Roo�Loading Live(Roo� Normal 1 0
Loadings-6
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations
All Dead LC
Active Design Criteria: <none>
Loed/ng Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Dead+ Balance LC
Active Design Criteria: <none>
Loading StandaMFactor A/t.Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Initial Service LC
Active Design Criteria: Initial Service Design
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1.13 1.13
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 1 1
Other Dead Loading 0 0
Live(Reducibie)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-7
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (2)
Seroice LC: D+(1.0 � 0.0) L
Active Design Criteria: Service Design
Loading Standa�rlFacto� A/t Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducibie)Loading 1 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1 0
Sustained Service LC
Active Design Criteria: Sustained Service Design
Loading Standaid Facto� A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0.5 0.5
Live(Unreducible)Loading 0.5 0.5
Live(Storage)Loading 1 1
Live(Roo�Loading 0.5 0.5
Factored LC: 1.4D
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Facto� A/t.Enve%pe Factoi
Self-Dead Loading 1.4 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.4 0.9
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-8
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (3)
Factored LC: 1.2D+ 1.6L+0.5Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Load/ng StandaMFactor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 1.6 0
Live(Unreducible)Loading 1.6 0
Live(Storage)Loading 1.6 0
Live(Roo�Loading 0.5 0
Factored LC: 1.2D+f1 L+ 1.6Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Factor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 0.5 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1.6 0
Long-Term Deflection LC
Active Design Criteria: <none>
Loading Standaid Factor A/t Enve�p�e Factor
Self-Dead Loading 3.35 3.35
Balance Loading 3.35 3.35
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 3.35 3.35
Live(Reducible)Loading 2.18 2.18
Live(Unreducible)Loading 2.18 2.18
Live(Storage)Loading 3.35 3.35
Live(Roo�Loading 2.18 2.18
Load Combinations-9
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Load Combinations (4)
Live Load
Active Design Criteria: <none>
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 0 0
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 0 0
Live(Reducible)Loading 1 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-10
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Rules
Code Minimum Design
318-02 Min.Reinforcement
User Minimum Design
Specified Min.Reinforcement
Initial Service Design
318-02 Initial Service Design
Service Design
318-02 Service Design
Include detailed section analysis
Sustained Service Design
318-02 Sustained Service Design
Strength Design
318-02 Strength Design
Punching Shear Design
Ductility Design
318-02 Ductility Design
Design Rules-11
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Mesh Input: Standard Plan
Mesh Input: User Notes; User Lines; User Dimensions; Slab Area Priorities; Beam Priorities; Point Supports; Point S�
Drawing Import: User Notes; User Lines; User Dimensions;
Design Strip: Latitude SSSs;
Scale = 1 :65
�
;
Mesh Input:Standard Plan-12
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Standard Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
Element:Standard Plan-13
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
:
Element:Slab Summary Plan-14
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Below Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Element Thicknesses; Wall Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
t=8
h- 0
� Fix,Pin Rigid
Shear
5000 psi
t=8
h- 0
Fix,Pin Rigid
Shear
5000 psi
Element:Supports Below Slab Summary Plan-15
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Above Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Above; Wall Element Thicknesses; Wail Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
�
Element:Supports Above Slab Summary Plan-16
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Temporary Construction (At Stressing) Loading: All Loads Plan
Temporary Construction (At Stressing) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Temporary Construction(At Stressing)Loading:All Loads Plan-17
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Other Dead Loading: All Loads Plan
Other Dead Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=333
�� Fz=333 Fz=455
1-
• � � z=
Fz=455
Fz=333
Fz=333
�,,,n� �f t��
= - � ''�-
Fz=455
Fz=455
i
�
�
,
Other Dead Loading:All Loads Plan-18
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Reducible) Loading: All Loads Pian
Live (Reducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Valu
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=133
z=
Fz=133
Fz=133
•' ;
..
Fz=182
Fz=182
Fz=182
Live(Reducible)Loading:All Loads Plan-19
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Unreducible) Loading: Ail Loads Plan
Live (Unreducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load V�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Lc��, �'�,,, �a� a��.
k _
Live(Unreducible)Loading:All Loads Plan-20
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Storage) Loading: All Loads Plan
Live (Storage) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Value�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Storage)Loading:All Loads Plan-21
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Roo� Loading: All Loads Plan
Live (Roof) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Roofl Loading:All Loads Plan-22
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Service LC: D + (1 .0 � 0.0) L: Deflection Plan
Service LC: D + (1 .0 � 0.0) L: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1:65
Vertical Deflection Plot
�� �
� '� ����� �, �
,d��R.��.�.��.�_.�,�
0 0.08 0.16 0.24 0.32 0.4 0.48 0.56 0.64
Min Value = -0.09401 inches @ (23,-1 .75) Max Value = 0.6725 inches @ (0.0164,-2.75)
Service LC:D+(1.0�0.0)L:Deflection Plan-23
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Mx Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (X-Axis direction)
One Contour = 0.1 Kips
Min Value = -6.739 Kips @ (0,1 .5) Max Value = 1 .114 Kips C� (11 .25,1)
Factored LC:1.4D:Mx Plan-24
Vaiis Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: My Plan
Factored LC: 1.4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (Y-Axis direction)
One Contour = 5 Kips
Min Value = -220.4 Kips @ (15,1 .5) Max Value = 13.79 Kips @ (33,1)
Factored LC:1.4D:My Plan-25
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Reactions Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
�
0
T
� �
T T
rn
0
T
�
�
�
�
••
�
TT
V,
Q
..
•
•
Factored LC:1.4D:Reactions Plan-26
a
Vail, Colorado
Denver, Colorado
Frisco, Colorado
�
Monroe 8� Newell
Engineers, Inc.
September 27,2006
4240 Architecture
1621 Eighteenth Street, Suite 200
Denver,CO 80202
Attn: Randy Hart
Re: Vail's Front Door(M&N#5500.02)Building A and Site
BUII.DING PERMIT#:B06-0018 �.�,�� _ ���
Dear Mr.Hart:
The following are our responses to the structural portions of The Town of Vail Building
Department comments for the above building,dated August 22,2006.We have included the
original comment with each response. Our September 27, 2006 responses are noted with"M&N
Response(9/27/06)"and are shown in red.
BUILDING DEPARTMENT COMMENTS:
ASI A-001, dated 6/15/06: Parking garage entry way modifications
5. S109: Plan view at new lid modifications over new ramp below: Verify
superimposed dead foading is sufficient in this area, structural cafculations have
not been submitted and loads can not be verified. Section 3 &4/A203 show several
feet of soil overtop, along with planter/site walls, topping slabs throughout, and
the concrete and CMU shaft wall around the exhaust shaft. lBC 1604.4.
HES 9/18/06: Dead loads appear too low: ca�ulations show 250 psf dead bad.This
load accounts for 8"slab plus 4"topping, plus 10"of 120 pcf soil. Section 3/A203
shows that 8"soil is the minimum depth,additional dead loads due to greater soil
depth,sidewalks and planter walls appear omittect.Additionally, it is unclear if post
tensioned beam seif weight is included. PT beam calcuiations have bwe�prestress
for PB13(482k in calcs vs.589k on S003)and higher prestress for PB15(295k in
calcs vs.214k on S003), please check designs.
:
�
��.'?._�a�
.,...
�
2006 Platinum Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
C303) 623-4927 • FAX <303) 623-6602 . email: denver�monroe-newell.com
M&N Response (9/27/06)
The computer model accounts for the self weight of the 8" thick concrete slab.
The remaining 100 psf of dead foad accounts for the possible additional soil, the
sidewalks, and the planter walls.
The self weight of the post-tensioned beam is accounted for and included in the
computer model.
Refer to the attached SSK-A033 for the revised "Post-Tensioned Beam
Schedule" from sheet S003 with the corrected "effective forces" and "bottom of
concrete to cgs" for Beams PB13 and PB15.
No revisions are required to the designs.
10. 16/S303: steel columns are not called out on plan, verify small shed roof snow
loads have been considered in the design of columns, header, and supporting slab
and other structure below. tBC 1604.4, 1603.1
HES 9/18/06: Roof point�ads are not shown in PT beam calculatior�s,please verify
this loading is included as indicated. EOR coordinate column call out, not shown on
plan or section.
M&N Response (9/27/06)
Refer to the attached revised PT calculations for Beam PB13 with the point
loads from the up columns. The columns are noted as "by others". Monroe &
Newell Engineers, Inc. and Hyder Construction will coordinate with the Engineer
of Reco�d for the South Lodge Tower Project.
End of Comment Responses.
If you have any questions or comments,please catl our office.
Very truly yours,
���uur�rrrr;..
M , ��i�L ENGINEERS,INC.
.
2, ,�`•.
s :
1 �
� :
:'��s .:
Pe� •�:
.�
Prmctp�'�F�C •...••
m �. � �
m
0
�
Q �
�i � ^F ^F
�Q � �Q 1--1
3L� 3� �
�
� w�D � wl� m �
�� J� 0
6� 6r Q 0 —
�
� � � �
� �
�u Q �
� � � � � �
'� � ry n � � Q
� � �
c� U
�
= 0 �
1 � n h �
1� �
�
�
� �
�
I ry h h
� � � �
�
l.t_i �
m �n �
� � � � �
0 0
�
� <Q <Q
a _� _�
Q �
t�chitectofRecotd Va.ils Front Door oRaw�NC No: SSK A-033
424o Building A
REFERENCE: 5003
Ownei/Devdopes ISSUE: ASI A-001
V311 RCSOttS DATE: 09/27/O6
Develo ment Com ari SCALE: N.T.S.
Denvec,Colocado p p y
Avoa,Coloxado DRAWN BY: CLH
Vail, Colorado
Denver, Colorado
Frisco, Colorado
Monroe 8� Newell
Engineers, Inc.
STRUCTURAL ENGINEERING CALCULATIONS
(Supplemental) �
For:
Vail's Front Door
Building "A" Garage / Site
Building Permit #B06-0018
(responding to ASI A-001)
Vail, Colorado
M&N #5500.02
```,,����a���au.��':
��� � �;;
s �
_
z =
�` :
'�.7 ti+;.""�PO.
�e
y�'�i F Cd►-d�'.
�:��iin�. .�
These drawings and calculations are the property of Monroe&Newell Engineers,Inc. Any use or
reproductions of these calculations without the expressed written permission of Monroe&Newell
Engineers,Inc.is strictly prohibited.
**P.E. stamp on sheet applies to the following calculation pages and indicates that have been reviewed.
This includes all sheets attached to this cover.
September 27, 2006
. �
:-•::.:•
2006 Plati Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
<303) 623-4927 • FAX (303) 623-6602 . email: denver�monroe-newell.com
-T-�-��'t � �o
Vails Front Door
Project #5500.02
Post-Tensioned Beam PB13
�
� �
�, ,
���
�
�� � .
.�. � �
,
Peter's Beam PB13-Point Load Roof.cpt
9/26/2006
Monroe and Newell Engineers,Inc.
RAM Concept m 2008 Bentley Systems,Inc.
RAM Concept°is a trademark of Bentley Systems,Inc.
2.02
'OR SiZE.
E
GONSTRUGTION
JOINT
INDIGATES FAGE OF I
EXISTIN6 LODGE
TOWER BUILDIDI� i
aiar-a in• I
eo�rror+ar i•-o•
PARALLEL 70 BE
TOP OF GONGRE'
ELEVATION � 8L
0
r---"' -\ ' '_'
b'WIDE GONGRETE /� i i P I
GURB WITH +5 HORI2. � AOII ^` �� 8180'-'1� � i
AND K4 X DOWEL � AOtI � i i TOP OF�� �
AT I'-b" J9� j� I I � GONGRE i
q• �� .'��`� �' 1�' 3p �
8 1 8 1'-4 I/2' � -.n�O�V. _�__���F�,,1i BO�EM OF A(3EAM �
BqE i
RE.ARGH FpR ���b� - ��' Ib AS REQUtf2ED �
�• .
OPENIN6 LOGATION �
' i i � ___ __PBI3_�
'�••-�" '�"' �V� "' -�"�-'��'��'
UP ONLY BY �� �
_i i . --
i
OTHERS - _""_'IS_ -- �"'i"_"."--"'_"__"_' �
8181'-4 1/2' i___ r�_ / b180•_�"
�i
I _I I . �
8181'-8 I/2' /� A51 A-001 i ppINT
L
A017 _ ��
TOP OF EXISTIN6 ----------� ��
- ' r�'__---".'r'.;-"""--"_'_""_ '
CANGRETE S�AB _�� � � --
.. __'--°--_ _'_ L�___'_ t-'-�--'__---°�_�___ '
ON STEEL.IOISTS -' i i
� JOINT � i i PB14 \
PIGAU `
.
AOI"1 � I I/ PBI4 \.
� �������������� � ��_�.����������
y�'r"-----°�i�-�-'-� '
8181'-4 I/�' �� � —-
_ ���__����� � w�.�_�_������L�������������������� '
� II
� ii
/ �� \\
8181'-4 I/�' � /� .i i
� Apl7 � � i� PBI4
�
�� ��-- ��-��'��"���--°����"�'�-��'����
/`2 4 �� '
-'-"-"'
ii —-
' " ' 'r�"'----""--°---_-'__°------�- �
B13-SP N 1 i i
� A51 A-001 i� �
8181'-3" i I i i 19
I � , 8181'-4 I�' �I A51 A-001 (
i ii
���T� ��_���______�� �_��� ���� _ _ _
� __ �_�___������_�1 � ��� �JJ�A��__�_ 1 i
i � 7_�__
- -�— �— — —_'_B2l__' � ----� tJ' - - � ----
� r---_' '__ -_'___------' I_ -____'__ __ --_'_ ___ __'___._ _
- �'�'
.__-- ---y-_-_�____J_-_-___r_� 8i8P_3. 8i80'-i0
T i GONSTRUGTI
I � JOINT I LOW POINT ,
SLOPE � _/_\___}_________'__"___������-� �'_�'�'
r------ -----°
18 I 1 � � J 1\ � �
`------ -'-'�'�� "-'-'--'-���J
� 4�-6� L`
�L `� `
�q._Z.
28'_�•
i
18
1
4
S�0
� �
�,�
�
ZIJ
��_
F�F
��Q
❑�
❑
�
�
8181._3`
'�-�---� -°---,�_�--
' __ ______________
� i
i �
�
� i SL� OPE
1 �
, � 1
Iry� I
�m 1
1 �
� �
� i
i � I
�,,,�,.�, �,�ar � Q ��
�.�,�___ r...,� 1��+►�
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
UnItS
Geometry Units
Plan Dimensions:feet Slab Thickness:inches Support Dimensions:inches
Angles:degrees Elevations:inches Support Height:feet
Loading and Reaction Units
Point Force:Kips Line Force:kips/ft Area Force:psf
-Report As Zero:0 Kips -Report As Zero:0 kips/ft -Report As Zero:0 psf
Point Moment:kip-ft Line Moment:pounds Area Moment:#/foot
-Report As Zero:0 kip-ft -Report As Zero:0 pounds -Report As Zero:0#/foot
Spring and Stiffness Units
Point Force Spring:kips/in Line Force Spring:ksi Area Force Spring:pci
Point Moment Spring:k-ft/° Line Moment Spring:k/4 Area Moment Spring:k/ftg
Slab Analysis Units
Force:Kips Moment:kip-ft Concrete Stress:psi
-Report As Zero:0 Kips -Report As Zero:0 kip-ft -Report As Zero:0 psi
Force Per�dth:kips/ft Moment Per Width:Kips Deflection:inches
-Report As Zero:0 kips/ft -Report As Zero:0 Kips -Report As Zero:0 inches
Materials Units
Concrete Volume:cu.yds Reinforcing Area:sq.in. PT Force:Kips
Rebar Weight:tons Tendon Profile:inches Reinforcing Stress:ksi
PT Weight:pounds Cover:inches
Miscellaneous Units
Floor Area:sq.ft. Density:pcf Elongations:inches
Tendon Ang�es(for friction):radians
Units-2
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Signs
Positive Loads
—� � � �
Positive Analysis
� �
� � � ....
� �� ,� �... . ..�
'�� 'F' rf.... ..�f�
.
:r
�...........r
r...� �-..
�
� � �� � �
.�, � ��...�� ,.
�, ti, ��
ti, •ti ��
ti, •��
~'�
Positive Reactions
�
� � � � �
��
Signs-3
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials
Concrete Mix
Ma Density fci Pc fcui fcu Poissons User Ec/ User Ec
Name (pct) (psi) (psi) (psi) (psi) Rat/o Ec Ca/c (psll (Rsil
3000 psi 150 3000 3000 3725 3725 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
4000 psi 150 3000 4000 3725 4975 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
5000 psi 150 3000 5000 3725 6399 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
6000 psi 150 3000 6000 3725 7450 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
PT Systems
System Aps Eps fse fpy fpu Duct Width Strdnds Min Radius
Name Type (sq.in.) (ks!) (ksi) (ksJ) (ksi) (fnches) Pe�Duct (feet)
'/z"Unbonded unbonded 0.153 28000 175 243 270 0.5 1 6
'/�"Bonded bonded 0.153 28000 160 243 270 3 4 6
0.6"Unbonded unbonded 0.217 28000 175 243 270 0.6 1 8
0.6"Bonded bonded 0.217 28000 160 243 270 4 4 8
PT Stressing Parameters
System Jacking Stiess Seating Loss Anchor Wobb/e Frictlon Angu/ar Frict/on Lon�Teim Losses
Name (ksi) (inches) Fiiction (fil�eet) (>/rad/ansJ (ksf)
'/z'Unbonded 216 0.25 0 0.0014 0.07 22
'/�"Bo�ded 216 0.25 0.02 0.001 0.2 22
0.6"Unbonded 216 0.25 0 0.0014 0.07 22
0.6"Bonded 216 0.25 0.02 0.001 0.2 22
Reinforcing Bars
Bar As ES Fy
Name (ks!) (ks!) (ksl)
#3 0.11 29000 60
#4 0.2 29000 60
#5 0.31 29000 60
#6 0.44 29000 60
#7 0.6 29000 60
#8 0.79 29000 60
#9 1 29000 60
#10 1.27 29000 60
#11 1.56 29000 60
Materials-4
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials (2)
SSR Systems
StudA�a HeadA�a Min C/earHead Specified Stud Fy Stud Spacing Rounding Min Studs
SSR System Name (sq.In.) (sq.In.) Spacing(inches) Spacing(inches) (ks!) /nc�ement (inches) Per Rai/
3/8"SSR 0.11 1.11 0.5 None 50 0.25 2
1/2"SSR 0.196 1.96 0.5 None 50 0.25 2
5/8"SSR 0.307 3.07 0.5 None 50 0.25 2
3/4"SSR 0.442 4.42 0.5 None 50 0.25 2
Materials-5
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Loadings
Loadfng Name Type Ana/ysis On-Pattem Factor Oif-Pattem Factvr
Self-Dead Loading Self-Weight Normal 1 1
Balance Loading Balance Normal 1 1
Hyperstatic Loading Hyperstatic Hyperstatic 1 1
Temporary Construction(At Stressing)LoadilA,q�essing Dead Normal 1 1
Other Dead Loading Dead Normal 1 1
Live(Reducible)Loading Live(Reducible) Normal 1 0
Live(Unreducible)Loading Live(Unreducible) Normai 1 0
Live(Storage)Loading Live(Storage) Normal 1 0
Live(Roo�Loading Live(Roo� Normal 1 0
Loadings-6
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations
All Dead LC
Active Design Criteria: <none>
Loed/ng Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Dead+ Balance LC
Active Design Criteria: <none>
Loading StandaMFactor A/t.Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Initial Service LC
Active Design Criteria: Initial Service Design
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1.13 1.13
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 1 1
Other Dead Loading 0 0
Live(Reducibie)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-7
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (2)
Seroice LC: D+(1.0 � 0.0) L
Active Design Criteria: Service Design
Loading Standa�rlFacto� A/t Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducibie)Loading 1 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1 0
Sustained Service LC
Active Design Criteria: Sustained Service Design
Loading Standaid Facto� A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0.5 0.5
Live(Unreducible)Loading 0.5 0.5
Live(Storage)Loading 1 1
Live(Roo�Loading 0.5 0.5
Factored LC: 1.4D
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Facto� A/t.Enve%pe Factoi
Self-Dead Loading 1.4 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.4 0.9
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-8
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (3)
Factored LC: 1.2D+ 1.6L+0.5Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Load/ng StandaMFactor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 1.6 0
Live(Unreducible)Loading 1.6 0
Live(Storage)Loading 1.6 0
Live(Roo�Loading 0.5 0
Factored LC: 1.2D+f1 L+ 1.6Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Factor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 0.5 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1.6 0
Long-Term Deflection LC
Active Design Criteria: <none>
Loading Standaid Factor A/t Enve�p�e Factor
Self-Dead Loading 3.35 3.35
Balance Loading 3.35 3.35
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 3.35 3.35
Live(Reducible)Loading 2.18 2.18
Live(Unreducible)Loading 2.18 2.18
Live(Storage)Loading 3.35 3.35
Live(Roo�Loading 2.18 2.18
Load Combinations-9
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Load Combinations (4)
Live Load
Active Design Criteria: <none>
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 0 0
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 0 0
Live(Reducible)Loading 1 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-10
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Rules
Code Minimum Design
318-02 Min.Reinforcement
User Minimum Design
Specified Min.Reinforcement
Initial Service Design
318-02 Initial Service Design
Service Design
318-02 Service Design
Include detailed section analysis
Sustained Service Design
318-02 Sustained Service Design
Strength Design
318-02 Strength Design
Punching Shear Design
Ductility Design
318-02 Ductility Design
Design Rules-11
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Mesh Input: Standard Plan
Mesh Input: User Notes; User Lines; User Dimensions; Slab Area Priorities; Beam Priorities; Point Supports; Point S�
Drawing Import: User Notes; User Lines; User Dimensions;
Design Strip: Latitude SSSs;
Scale = 1 :65
�
;
Mesh Input:Standard Plan-12
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Standard Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
Element:Standard Plan-13
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
:
Element:Slab Summary Plan-14
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Below Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Element Thicknesses; Wall Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
t=8
h- 0
� Fix,Pin Rigid
Shear
5000 psi
t=8
h- 0
Fix,Pin Rigid
Shear
5000 psi
Element:Supports Below Slab Summary Plan-15
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Above Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Above; Wall Element Thicknesses; Wail Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
�
Element:Supports Above Slab Summary Plan-16
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Temporary Construction (At Stressing) Loading: All Loads Plan
Temporary Construction (At Stressing) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Temporary Construction(At Stressing)Loading:All Loads Plan-17
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Other Dead Loading: All Loads Plan
Other Dead Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=333
�� Fz=333 Fz=455
1-
• � � z=
Fz=455
Fz=333
Fz=333
�,,,n� �f t��
= - � ''�-
Fz=455
Fz=455
i
�
�
,
Other Dead Loading:All Loads Plan-18
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Reducible) Loading: All Loads Pian
Live (Reducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Valu
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=133
z=
Fz=133
Fz=133
•' ;
..
Fz=182
Fz=182
Fz=182
Live(Reducible)Loading:All Loads Plan-19
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Unreducible) Loading: Ail Loads Plan
Live (Unreducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load V�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Lc��, �'�,,, �a� a��.
k _
Live(Unreducible)Loading:All Loads Plan-20
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Storage) Loading: All Loads Plan
Live (Storage) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Value�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Storage)Loading:All Loads Plan-21
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Roo� Loading: All Loads Plan
Live (Roof) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Roofl Loading:All Loads Plan-22
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Service LC: D + (1 .0 � 0.0) L: Deflection Plan
Service LC: D + (1 .0 � 0.0) L: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1:65
Vertical Deflection Plot
�� �
� '� ����� �, �
,d��R.��.�.��.�_.�,�
0 0.08 0.16 0.24 0.32 0.4 0.48 0.56 0.64
Min Value = -0.09401 inches @ (23,-1 .75) Max Value = 0.6725 inches @ (0.0164,-2.75)
Service LC:D+(1.0�0.0)L:Deflection Plan-23
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Mx Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (X-Axis direction)
One Contour = 0.1 Kips
Min Value = -6.739 Kips @ (0,1 .5) Max Value = 1 .114 Kips C� (11 .25,1)
Factored LC:1.4D:Mx Plan-24
Vaiis Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: My Plan
Factored LC: 1.4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (Y-Axis direction)
One Contour = 5 Kips
Min Value = -220.4 Kips @ (15,1 .5) Max Value = 13.79 Kips @ (33,1)
Factored LC:1.4D:My Plan-25
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Reactions Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
�
0
T
� �
T T
rn
0
T
�
�
�
�
••
�
TT
V,
Q
..
•
•
Factored LC:1.4D:Reactions Plan-26
a
Vail, Colorado
Denver, Colorado
Frisco, Colorado
�
Monroe 8� Newell
Engineers, Inc.
September 27,2006
4240 Architecture
1621 Eighteenth Street, Suite 200
Denver,CO 80202
Attn: Randy Hart
Re: Vail's Front Door(M&N#5500.02)Building A and Site
BUII.DING PERMIT#:B06-0018 �.�,�� _ ���
Dear Mr.Hart:
The following are our responses to the structural portions of The Town of Vail Building
Department comments for the above building,dated August 22,2006.We have included the
original comment with each response. Our September 27, 2006 responses are noted with"M&N
Response(9/27/06)"and are shown in red.
BUILDING DEPARTMENT COMMENTS:
ASI A-001, dated 6/15/06: Parking garage entry way modifications
5. S109: Plan view at new lid modifications over new ramp below: Verify
superimposed dead foading is sufficient in this area, structural cafculations have
not been submitted and loads can not be verified. Section 3 &4/A203 show several
feet of soil overtop, along with planter/site walls, topping slabs throughout, and
the concrete and CMU shaft wall around the exhaust shaft. lBC 1604.4.
HES 9/18/06: Dead loads appear too low: ca�ulations show 250 psf dead bad.This
load accounts for 8"slab plus 4"topping, plus 10"of 120 pcf soil. Section 3/A203
shows that 8"soil is the minimum depth,additional dead loads due to greater soil
depth,sidewalks and planter walls appear omittect.Additionally, it is unclear if post
tensioned beam seif weight is included. PT beam calcuiations have bwe�prestress
for PB13(482k in calcs vs.589k on S003)and higher prestress for PB15(295k in
calcs vs.214k on S003), please check designs.
:
�
��.'?._�a�
.,...
�
2006 Platinum Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
C303) 623-4927 • FAX <303) 623-6602 . email: denver�monroe-newell.com
M&N Response (9/27/06)
The computer model accounts for the self weight of the 8" thick concrete slab.
The remaining 100 psf of dead foad accounts for the possible additional soil, the
sidewalks, and the planter walls.
The self weight of the post-tensioned beam is accounted for and included in the
computer model.
Refer to the attached SSK-A033 for the revised "Post-Tensioned Beam
Schedule" from sheet S003 with the corrected "effective forces" and "bottom of
concrete to cgs" for Beams PB13 and PB15.
No revisions are required to the designs.
10. 16/S303: steel columns are not called out on plan, verify small shed roof snow
loads have been considered in the design of columns, header, and supporting slab
and other structure below. tBC 1604.4, 1603.1
HES 9/18/06: Roof point�ads are not shown in PT beam calculatior�s,please verify
this loading is included as indicated. EOR coordinate column call out, not shown on
plan or section.
M&N Response (9/27/06)
Refer to the attached revised PT calculations for Beam PB13 with the point
loads from the up columns. The columns are noted as "by others". Monroe &
Newell Engineers, Inc. and Hyder Construction will coordinate with the Engineer
of Reco�d for the South Lodge Tower Project.
End of Comment Responses.
If you have any questions or comments,please catl our office.
Very truly yours,
���uur�rrrr;..
M , ��i�L ENGINEERS,INC.
.
2, ,�`•.
s :
1 �
� :
:'��s .:
Pe� •�:
.�
Prmctp�'�F�C •...••
d � �
� N �
� �,
� O �
o �.
d �
� �
o �
�� � � ��
� � �e �:o
° n o �. orc� �-�r
� o �
o� � � ��
� O
`� O
n
0
�
D
o m �
n r+�j Z
�� � �
z�oinm
�Z
����� Z
[mmmm O
c�zoacn �
r• �O(AO
=�ND� �
V � ✓�
�O
O p
°'� a
0
�
�
0
ASI A 001
�
ASI A-001
PBI2
�
PB13
—
��
PB15
�4"
�4"
�4"
—
��.
�..
28"
—
�8"
�,.
40�IG
�,�
48�iG
—
�G51G
—
�68K
18" e
Iq" LEFT (WEST)
14" RI6HT (EAST)
�m��� ��``"�°
���
I�I" LEFT (WEST)
I'1° RI6HT (EAST)
SSK A-033
�'� i�T � � � �OST T � l�ls � 0i�1 � 1�
� � �1`� SC � � l� l� � �
/5��3 � � DC�_ ' � '
A-033 3��
� 18
�
�� 18
Vail, Colorado
Denver, Colorado
Frisco, Colorado
Monroe 8� Newell
Engineers, Inc.
STRUCTURAL ENGINEERING CALCULATIONS
(Supplemental) �
For:
Vail's Front Door
Building "A" Garage / Site
Building Permit #B06-0018
(responding to ASI A-001)
Vail, Colorado
M&N #5500.02
```,,����a���au.��':
��� � �;;
s �
_
z =
�` :
'�.7 ti+;.""�PO.
�e
y�'�i F Cd►-d�'.
�:��iin�. .�
These drawings and calculations are the property of Monroe&Newell Engineers,Inc. Any use or
reproductions of these calculations without the expressed written permission of Monroe&Newell
Engineers,Inc.is strictly prohibited.
**P.E. stamp on sheet applies to the following calculation pages and indicates that have been reviewed.
This includes all sheets attached to this cover.
September 27, 2006
. �
:-•::.:•
2006 Plati Sponsor
The Colorado Chapter of
The American Institute of Architects
www.monroe-newell.com
1701 Wynkoop Street • Suite 200 • Denver, Colorado 80202
<303) 623-4927 • FAX (303) 623-6602 . email: denver�monroe-newell.com
-T-�-��'t � �o
Vails Front Door
Project #5500.02
Post-Tensioned Beam PB13
�
� �
�, ,
���
�
�� � .
.�. � �
,
Peter's Beam PB13-Point Load Roof.cpt
9/26/2006
Monroe and Newell Engineers,Inc.
RAM Concept m 2008 Bentley Systems,Inc.
RAM Concept°is a trademark of Bentley Systems,Inc.
2.02
'OR SiZE.
E
GONSTRUGTION
JOINT
INDIGATES FAGE OF I
EXISTIN6 LODGE
TOWER BUILDIDI� i
aiar-a in• I
eo�rror+ar i•-o•
PARALLEL 70 BE
TOP OF GONGRE'
ELEVATION � 8L
0
r---"' -\ ' '_'
b'WIDE GONGRETE /� i i P I
GURB WITH +5 HORI2. � AOII ^` �� 8180'-'1� � i
AND K4 X DOWEL � AOtI � i i TOP OF�� �
AT I'-b" J9� j� I I � GONGRE i
q• �� .'��`� �' 1�' 3p �
8 1 8 1'-4 I/2' � -.n�O�V. _�__���F�,,1i BO�EM OF A(3EAM �
BqE i
RE.ARGH FpR ���b� - ��' Ib AS REQUtf2ED �
�• .
OPENIN6 LOGATION �
' i i � ___ __PBI3_�
'�••-�" '�"' �V� "' -�"�-'��'��'
UP ONLY BY �� �
_i i . --
i
OTHERS - _""_'IS_ -- �"'i"_"."--"'_"__"_' �
8181'-4 1/2' i___ r�_ / b180•_�"
�i
I _I I . �
8181'-8 I/2' /� A51 A-001 i ppINT
L
A017 _ ��
TOP OF EXISTIN6 ----------� ��
- ' r�'__---".'r'.;-"""--"_'_""_ '
CANGRETE S�AB _�� � � --
.. __'--°--_ _'_ L�___'_ t-'-�--'__---°�_�___ '
ON STEEL.IOISTS -' i i
� JOINT � i i PB14 \
PIGAU `
.
AOI"1 � I I/ PBI4 \.
� �������������� � ��_�.����������
y�'r"-----°�i�-�-'-� '
8181'-4 I/�' �� � —-
_ ���__����� � w�.�_�_������L�������������������� '
� II
� ii
/ �� \\
8181'-4 I/�' � /� .i i
� Apl7 � � i� PBI4
�
�� ��-- ��-��'��"���--°����"�'�-��'����
/`2 4 �� '
-'-"-"'
ii —-
' " ' 'r�"'----""--°---_-'__°------�- �
B13-SP N 1 i i
� A51 A-001 i� �
8181'-3" i I i i 19
I � , 8181'-4 I�' �I A51 A-001 (
i ii
���T� ��_���______�� �_��� ���� _ _ _
� __ �_�___������_�1 � ��� �JJ�A��__�_ 1 i
i � 7_�__
- -�— �— — —_'_B2l__' � ----� tJ' - - � ----
� r---_' '__ -_'___------' I_ -____'__ __ --_'_ ___ __'___._ _
- �'�'
.__-- ---y-_-_�____J_-_-___r_� 8i8P_3. 8i80'-i0
T i GONSTRUGTI
I � JOINT I LOW POINT ,
SLOPE � _/_\___}_________'__"___������-� �'_�'�'
r------ -----°
18 I 1 � � J 1\ � �
`------ -'-'�'�� "-'-'--'-���J
� 4�-6� L`
�L `� `
�q._Z.
28'_�•
i
18
1
4
S�0
� �
�,�
�
ZIJ
��_
F�F
��Q
❑�
❑
�
�
8181._3`
'�-�---� -°---,�_�--
' __ ______________
� i
i �
�
� i SL� OPE
1 �
, � 1
Iry� I
�m 1
1 �
� �
� i
i � I
�,,,�,.�, �,�ar � Q ��
�.�,�___ r...,� 1��+►�
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
UnItS
Geometry Units
Plan Dimensions:feet Slab Thickness:inches Support Dimensions:inches
Angles:degrees Elevations:inches Support Height:feet
Loading and Reaction Units
Point Force:Kips Line Force:kips/ft Area Force:psf
-Report As Zero:0 Kips -Report As Zero:0 kips/ft -Report As Zero:0 psf
Point Moment:kip-ft Line Moment:pounds Area Moment:#/foot
-Report As Zero:0 kip-ft -Report As Zero:0 pounds -Report As Zero:0#/foot
Spring and Stiffness Units
Point Force Spring:kips/in Line Force Spring:ksi Area Force Spring:pci
Point Moment Spring:k-ft/° Line Moment Spring:k/4 Area Moment Spring:k/ftg
Slab Analysis Units
Force:Kips Moment:kip-ft Concrete Stress:psi
-Report As Zero:0 Kips -Report As Zero:0 kip-ft -Report As Zero:0 psi
Force Per�dth:kips/ft Moment Per Width:Kips Deflection:inches
-Report As Zero:0 kips/ft -Report As Zero:0 Kips -Report As Zero:0 inches
Materials Units
Concrete Volume:cu.yds Reinforcing Area:sq.in. PT Force:Kips
Rebar Weight:tons Tendon Profile:inches Reinforcing Stress:ksi
PT Weight:pounds Cover:inches
Miscellaneous Units
Floor Area:sq.ft. Density:pcf Elongations:inches
Tendon Ang�es(for friction):radians
Units-2
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Signs
Positive Loads
—� � � �
Positive Analysis
� �
� � � ....
� �� ,� �... . ..�
'�� 'F' rf.... ..�f�
.
:r
�...........r
r...� �-..
�
� � �� � �
.�, � ��...�� ,.
�, ti, ��
ti, •ti ��
ti, •��
~'�
Positive Reactions
�
� � � � �
��
Signs-3
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials
Concrete Mix
Ma Density fci Pc fcui fcu Poissons User Ec/ User Ec
Name (pct) (psi) (psi) (psi) (psi) Rat/o Ec Ca/c (psll (Rsil
3000 psi 150 3000 3000 3725 3725 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
4000 psi 150 3000 4000 3725 4975 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
5000 psi 150 3000 5000 3725 6399 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
6000 psi 150 3000 6000 3725 7450 0.2 ACI 8.5.1 (no Wc) 2500000 3000000
PT Systems
System Aps Eps fse fpy fpu Duct Width Strdnds Min Radius
Name Type (sq.in.) (ks!) (ksi) (ksJ) (ksi) (fnches) Pe�Duct (feet)
'/z"Unbonded unbonded 0.153 28000 175 243 270 0.5 1 6
'/�"Bonded bonded 0.153 28000 160 243 270 3 4 6
0.6"Unbonded unbonded 0.217 28000 175 243 270 0.6 1 8
0.6"Bonded bonded 0.217 28000 160 243 270 4 4 8
PT Stressing Parameters
System Jacking Stiess Seating Loss Anchor Wobb/e Frictlon Angu/ar Frict/on Lon�Teim Losses
Name (ksi) (inches) Fiiction (fil�eet) (>/rad/ansJ (ksf)
'/z'Unbonded 216 0.25 0 0.0014 0.07 22
'/�"Bo�ded 216 0.25 0.02 0.001 0.2 22
0.6"Unbonded 216 0.25 0 0.0014 0.07 22
0.6"Bonded 216 0.25 0.02 0.001 0.2 22
Reinforcing Bars
Bar As ES Fy
Name (ks!) (ks!) (ksl)
#3 0.11 29000 60
#4 0.2 29000 60
#5 0.31 29000 60
#6 0.44 29000 60
#7 0.6 29000 60
#8 0.79 29000 60
#9 1 29000 60
#10 1.27 29000 60
#11 1.56 29000 60
Materials-4
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Materials (2)
SSR Systems
StudA�a HeadA�a Min C/earHead Specified Stud Fy Stud Spacing Rounding Min Studs
SSR System Name (sq.In.) (sq.In.) Spacing(inches) Spacing(inches) (ks!) /nc�ement (inches) Per Rai/
3/8"SSR 0.11 1.11 0.5 None 50 0.25 2
1/2"SSR 0.196 1.96 0.5 None 50 0.25 2
5/8"SSR 0.307 3.07 0.5 None 50 0.25 2
3/4"SSR 0.442 4.42 0.5 None 50 0.25 2
Materials-5
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Loadings
Loadfng Name Type Ana/ysis On-Pattem Factor Oif-Pattem Factvr
Self-Dead Loading Self-Weight Normal 1 1
Balance Loading Balance Normal 1 1
Hyperstatic Loading Hyperstatic Hyperstatic 1 1
Temporary Construction(At Stressing)LoadilA,q�essing Dead Normal 1 1
Other Dead Loading Dead Normal 1 1
Live(Reducible)Loading Live(Reducible) Normal 1 0
Live(Unreducible)Loading Live(Unreducible) Normai 1 0
Live(Storage)Loading Live(Storage) Normal 1 0
Live(Roo�Loading Live(Roo� Normal 1 0
Loadings-6
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations
All Dead LC
Active Design Criteria: <none>
Loed/ng Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Dead+ Balance LC
Active Design Criteria: <none>
Loading StandaMFactor A/t.Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Initial Service LC
Active Design Criteria: Initial Service Design
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1.13 1.13
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 1 1
Other Dead Loading 0 0
Live(Reducibie)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-7
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (2)
Seroice LC: D+(1.0 � 0.0) L
Active Design Criteria: Service Design
Loading Standa�rlFacto� A/t Enve%peFactor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducibie)Loading 1 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1 0
Sustained Service LC
Active Design Criteria: Sustained Service Design
Loading Standaid Facto� A/t.Enve%pe Factor
Self-Dead Loading 1 1
Balance Loading 1 1
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1 1
Live(Reducible)Loading 0.5 0.5
Live(Unreducible)Loading 0.5 0.5
Live(Storage)Loading 1 1
Live(Roo�Loading 0.5 0.5
Factored LC: 1.4D
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Facto� A/t.Enve%pe Factoi
Self-Dead Loading 1.4 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.4 0.9
Live(Reducible)Loading 0 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-8
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Load Combinations (3)
Factored LC: 1.2D+ 1.6L+0.5Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Load/ng StandaMFactor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 1.6 0
Live(Unreducible)Loading 1.6 0
Live(Storage)Loading 1.6 0
Live(Roo�Loading 0.5 0
Factored LC: 1.2D+f1 L+ 1.6Lr
Active Design Criteria: User Minimum Design, Code Minimum Design, Strength Design, Ductility Desig
Loading Standaid Factor A/t.Enve%pe Facto�
Self-Dead Loading 1.2 0.9
Balance Loading 0 0
Hyperstatic Loading 1 1
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 1.2 0.9
Live(Reducible)Loading 0.5 0
Live(Unreducible)Loading 1 0
Live(Storage)Loading 1 0
Live(Roofl Loading 1.6 0
Long-Term Deflection LC
Active Design Criteria: <none>
Loading Standaid Factor A/t Enve�p�e Factor
Self-Dead Loading 3.35 3.35
Balance Loading 3.35 3.35
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 3.35 3.35
Live(Reducible)Loading 2.18 2.18
Live(Unreducible)Loading 2.18 2.18
Live(Storage)Loading 3.35 3.35
Live(Roo�Loading 2.18 2.18
Load Combinations-9
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Load Combinations (4)
Live Load
Active Design Criteria: <none>
Loading Standaid Factor A/t.Enve%pe Factor
Self-Dead Loading 0 0
Balance Loading 0 0
Hyperstatic Loading 0 0
Temporary Construction(At Stressing)Loading 0 0
Other Dead Loading 0 0
Live(Reducible)Loading 1 0
Live(Unreducible)Loading 0 0
Live(Storage)Loading 0 0
Live(Roo�Loading 0 0
Load Combinations-10
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Rules
Code Minimum Design
318-02 Min.Reinforcement
User Minimum Design
Specified Min.Reinforcement
Initial Service Design
318-02 Initial Service Design
Service Design
318-02 Service Design
Include detailed section analysis
Sustained Service Design
318-02 Sustained Service Design
Strength Design
318-02 Strength Design
Punching Shear Design
Ductility Design
318-02 Ductility Design
Design Rules-11
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Mesh Input: Standard Plan
Mesh Input: User Notes; User Lines; User Dimensions; Slab Area Priorities; Beam Priorities; Point Supports; Point S�
Drawing Import: User Notes; User Lines; User Dimensions;
Design Strip: Latitude SSSs;
Scale = 1 :65
�
;
Mesh Input:Standard Plan-12
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Standard Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
Element:Standard Plan-13
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Elements Above; Column Elements
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
:
Element:Slab Summary Plan-14
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Below Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Below; Wall Element Thicknesses; Wall Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
t=8
h- 0
� Fix,Pin Rigid
Shear
5000 psi
t=8
h- 0
Fix,Pin Rigid
Shear
5000 psi
Element:Supports Below Slab Summary Plan-15
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Element: Supports Above Slab Summary Plan
Element: User Lines; User Notes; User Dimensions; Wall Elements Above; Wall Element Thicknesses; Wail Element
Drawing Import: User Lines; User Notes; User Dimensions;
Scale = 1 :65
�
Element:Supports Above Slab Summary Plan-16
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Temporary Construction (At Stressing) Loading: All Loads Plan
Temporary Construction (At Stressing) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Temporary Construction(At Stressing)Loading:All Loads Plan-17
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Other Dead Loading: All Loads Plan
Other Dead Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=333
�� Fz=333 Fz=455
1-
• � � z=
Fz=455
Fz=333
Fz=333
�,,,n� �f t��
= - � ''�-
Fz=455
Fz=455
i
�
�
,
Other Dead Loading:All Loads Plan-18
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Reducible) Loading: All Loads Pian
Live (Reducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Valu
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Fz=133
z=
Fz=133
Fz=133
•' ;
..
Fz=182
Fz=182
Fz=182
Live(Reducible)Loading:All Loads Plan-19
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Unreducible) Loading: Ail Loads Plan
Live (Unreducible) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load V�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Lc��, �'�,,, �a� a��.
k _
Live(Unreducible)Loading:All Loads Plan-20
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live (Storage) Loading: All Loads Plan
Live (Storage) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Value�
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Storage)Loading:All Loads Plan-21
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Live (Roo� Loading: All Loads Plan
Live (Roof) Loading: User Lines; User Notes; User Dimensions; Point Loads; Point Load Icons; Point Load Values; L
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Live(Roofl Loading:All Loads Plan-22
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Service LC: D + (1 .0 � 0.0) L: Deflection Plan
Service LC: D + (1 .0 � 0.0) L: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1:65
Vertical Deflection Plot
�� �
� '� ����� �, �
,d��R.��.�.��.�_.�,�
0 0.08 0.16 0.24 0.32 0.4 0.48 0.56 0.64
Min Value = -0.09401 inches @ (23,-1 .75) Max Value = 0.6725 inches @ (0.0164,-2.75)
Service LC:D+(1.0�0.0)L:Deflection Plan-23
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Mx Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (X-Axis direction)
One Contour = 0.1 Kips
Min Value = -6.739 Kips @ (0,1 .5) Max Value = 1 .114 Kips C� (11 .25,1)
Factored LC:1.4D:Mx Plan-24
Vaiis Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: My Plan
Factored LC: 1.4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (Y-Axis direction)
One Contour = 5 Kips
Min Value = -220.4 Kips @ (15,1 .5) Max Value = 13.79 Kips @ (33,1)
Factored LC:1.4D:My Plan-25
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .4D: Reactions Plan
Factored LC: 1 .4D: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
�
0
T
� �
T T
rn
0
T
�
�
�
�
••
�
TT
V,
Q
..
•
•
Factored LC:1.4D:Reactions Plan-26
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + 1 .6L + 0.5Lr: Mx Pian
Factored LC: 1 .2D + 1 .6L + 0.5Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (X-Axis direction)
One Contour = 0.5 Kips
Min Value = -11 .74 Kips @ (0,1 .5) Max Value = 5.019 Kips @ (11 .25,1)
Factored LC: 1.2D+1.6L+0.5Lr:Mx Plan-27
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + 1 .6L + 0.5Lr: My Plan
Factored LC: 1 .2D + 1 .6L + 0.5Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (Y-Axis direction)
One Contour - 10 Kips
Min Value = -410.3 Kips @ (16,1.5) Max Value = 7.123 Kips @ (36,0.5)
Factored LC: 1.2D+1.6L+0.5Lr:My Plan-28
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + 1 .6L + 0.5Lr: Reactions Plan
Factored LC: 1 .2D + 1 .6L + 0.5Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
T'^
V J
r
�
T�/�
w J
�
NM
t'J
Factored LC:1.2D+1.6L+0.5Lr:Reactions Plan-29
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + f1 L + 1 .6Lr: Mx Plan
Factored LC: 1 .2D + f1 L + 1 .6Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (X-Axis direction)
One Contour = 0.2 Kips
Min Value = -8.12 Kips @ (0,1.5) Max Value = 2.956 Kips @ (11 .25,1)
Factored LC: 1.2D+f1 L+1.6Lr:Mx Plan-30
Vaiis Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + f1 L + 1 .6Lr: My Plan
Factored LC: 1 .2D + f1 L + 1 .6Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Bending Moment Plot (Y-Axis direction)
One Contour = 5 Kips
Min Value = -277.8 Kips @ (16,1.5) Max Value = 6.726 Kips @ (36,0.5)
Factored LC: 1.2D+f1 L+1.6Lr:My Plan-31
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Factored LC: 1 .2D + f1 L + 1 .6Lr: Reactions Plan
Factored LC: 1 .2D + f1 L + 1 .6Lr: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
d-
T
T
T
�
T
T
Q
�
�
�
��..y.
V
�
0
�
Factored LC:1.2D+fi L+1.6Lr:Reactions Plan-32
Vaiis Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Live Load: Deflection Plan
Live Load: User Lines; User Notes; User Dimensions;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Vertical Deflection Plot
� �
'�``��� ' ;�
-.„��
� � � � � � i � � • � � � � i �
Min Value = -0.04613 inches @ (23,-1 .75) Max Value = 0.332 inches @ (0.0164,-2.75)
Live Load:Deflection Plan-33
Vails Front Door-Peter's Beam P613-Point Load Roof:cpt-9/26/2006
Live Load: Reactions Plan
Live Load: User Lines; User Notes; User Dimensions; �
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Reaction Plot: (Wall Below,Column Below,Point Spring,Line Spring,Point Support,Line Support)(Fr,Fs,Fz,Mr,Ms,Mz)(
�
T
1
" -- '� - o
oo �.nco �
�����_!b
�
N �
O
� O O
Q
O �l! �"J �iJ � �
oo �rcfloar
i� �TI I���� N �J"�
�
Live Load:Reactions Plan-34
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Design Strip: Latitude Design Spans Plan
Design Strip: User Notes; User Lines; User Dimensions; Latitude Span Boundaries; Latitude Strip Boundaries; Latitu�
Drawing Import: User Notes; User Lines; User Dimensions;
Element: Wall Elements Above; Wall Elements Below; Column Elements Above; Column Elements Below; Slab Elerr
Scale = 1 :65
Design Strip:Latitude Design Spans Plan-35
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Design Strip: Longitude Design Spans Pian
Design Strip: User Lines; User Notes; User Dimensions; Longitude SSs; Longitude SSSs; Longitude DSs; Longitude
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Design Strip:Longitude Design Spans Plan-36
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Design Strip: Punching Checks Plan
Design Strip: User Lines; User Notes; User Dimensions; Punching Checks; Punching Check Sections;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Design Strip:Punching Checks Plan-37
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Latitude Tendon: Standard Plan
Latitude Tendon: User Notes; User Lines; User Dimensions; Tendons; Num Strands; Tendon Forces; Jacks; Profile F
Drawing Import: User Notes; User Lines; User Dimensions;
Element: Wall Elements Above; Wall Elements Below; Column Elements Above; Column Elements Below; Slab Elerr
Scale = 1 :65
Latitude Tendon:Standard Plan-38
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Longitude Tendon: Standard Plan
Longitude Tendon: User Lines; User Notes; User Dimensions; Tendons; Num Strands; Profile Points; Profile Values;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Longitude Tendon:Standard Plan-39
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Service Design: L.T. Deflection Plan
Service Design: User Lines; User Notes; User Dimensions; Latitude SSS Designs; Longitude SSS Designs; Latitude
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Section Analysis Plot: (Long Term Deflection)(Context: Max Demand)
� :
1 .75
00241--0.0191
0.0112 0.00057
Service Design:L.T.Deflection Plan-40
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Summary: Punching Shear Status Plan
Design Summary: User Lines; User Notes; User Dimensions; PC Designs; PC Design Numbers; PC Design Status; f
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Design Summary:Punching Shear Status Plan-41
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Summary: Latitude Status Plan
Design Summary: User Lines; User Notes; User Dimensions; Latitude SSS Designs; SSS Design Numbers; SSS De;
Drawing Import: User Lines; User Notes; User Dimensions;
Element: Wall Elements Below; Wall Elements Above; Column Elements Below; Column Elements Above; Slab Elerr
Scale = 1 :65
Design Summary:Latitude Status Plan-42
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Design Summary: Latitude Top Reinforcement Plan
Design Summary: User Notes; User Lines; User Dimensions; Latitude SSS Designs; SSS Design Top Bars; SSS De:
Drawing Import: User Notes; User Lines; User Dimensions;
Element: Wall Elements Above; Wall Elements Below; Column Elements Above; Column Elements Below; Slab Elerr
Scale = 1:65
Design Summary:Latitude Top Reinforcement Plan-43
Vails Front Door-Peter's Beam PB13-Point Load Roof.cpt-9/26/2006
Design Summary: Latitude Bottom Reinforcement Plan
Design Summary: User Notes; User Lines; User Dimensions; Latitude SSS Designs; SSS Design Bottom Bars; SSS
Drawing Import: User Notes; User Lines; User Dimensions;
Element: Wall Elements Above; Wall Elements Below• Column Elements Above� Col EI
Scale = 1 :65
4 #9 x 15 B.
a� � a� a�
� � � �
� , umn ements Below, Slab Elerr
II 4 #9x22B. �
a� a�a� a� a� a� a� a� a� a� a�a
_ �� � � � � � � � � �
- � -�,
Design Summary:Latitude Bottom Reinforcement Plan-44
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Calc Log
Calculating Everything Out-of-Date
Active Calculation Options:
The structure is not automatically stabilized in the X and Y directions.
Supports above slab NOT included in self-dead loading.
Tendon vertical component NOT considered in punch check reactions.
6 zero-tension iterations are used to eliminate tension in area spring�
Creep Factor of 2.18 used in ECR calculations.
Shrinkage strain of 0.0004 used in ECR calculations.
ACI 318-02 is used in design.
Live load reduction not used
Stiffness matrix is already up to date
Self-dead load creation is already up to date.
Balance load creation is already up to date.
Concrete cross section calcs are already up to date.
Tendon cross section calcs are already up to date.
Live load reduction calcs are already up to date.
All loading resuits are already up to date.
Hyperstatic results are already up to date.
All load combo results are already up to date.
Calculating Code Minimum Design envelopes.
Calculating User Minimum Design envelopes
Calculating Initial Service Design envelopes.
Calculating Service Design envelopes.
Calculating Sustained Service Design envelopes.
Calculating Strength Design envelopes.
Calculating Ductiliry Design envelopes.
Calculating Code Minimum Design-Pass'
Calculating User Minimum Design-Pass'
Calculating Initial Service Design-Pass 1
Calculating Service Design-Pass 1
Calculating Sustained Service Design-Pass 1
Calculating Strength Design-Pass 1
Calculating Ductility Design-Pass 1
Caiculating Code Minimum Design-Pass:
Calculating User Minimum Design-Pass:
Calculating Initiai Service Design-Pass 2
Calculating Service Design-Pass 2
Calculating Sustained Service Design-Pass 2
Calculating Strength Design-Pass 2
Calculating Ductility Design-Pass 2
Calculating Code Minimum Design-Final Design ChecF
Calculating User Minimum Design-Final Design ChecW
Calculating Initial Service Design-Final Design Check
Calculating Service Design-Final Design Check
Calculating Sustained Service Design-Finai Design Check
Calculating Strength Design-Final Design Check
Calculating Ductility Design-Final Design Check
This anaiysis has been completed successfully,check above for any warnings or errors.
Calc Log-45
Vails Front Door-Peter's Beam P613-Point Load Roof.cpt-9/26/2006
Estimate
Concrete Costs
Materials: 100 per cu.yds x 10.44 cu.yds = 1044
Labor: 50 per cu.yds x 10.44 cu.yds = 521,g
Total: 150 per cu.yds x 10.44 cu.yds = 1565
Post-Tensioning Costs
Materials: 1 per pounds x 349.9 pounds = 349.g
Labor: 0.5 per pounds x 349.9 pounds = �74,9
Total: 1.5 perpounds x 349.9 pounds = 524.8
Formwork Costs
Materials: 1 per sq.ft. x 236 sq.ft. = 236
Labor: 1 persq.ft. x 236 sq.ft. = 236
Total: 2 persq.ft. x 236 sq.ft. = 471.9
Mild Steel Reinforcing Costs
Materials: 1000 pertons x 0.5829 tons = 582.9
Labor: 500 pertons x 0.5829 tons = 291.4
Total: 1500 pertons x 0.5829 tons = 874.3
Total Costs
Materials: 9.375 per sq.ft. x 236 sq.ft. = 2212
Labor: 5.188 per sq.ft. x 236 sq.ft. = 122q
Total: 14.56 per sq.ft. x 236 sq.ft. = 3436
Estimate-46