Loading...
HomeMy WebLinkAbout#3 Structural Engineering CalculationsMonroe & Newell Engineers, Inc. Vail, Colorado Denver, Colorado Dillon, Colorado -~-~vdC, - coo 2 SC)c.- c> o z Z STRUCTURAL ENGINEERING CALCULATIONS For: Vail's Front Door Building "E" The Chalets at the Lodge at Vail Vail, Colorado M&N # 5500.02 OF a,0 waa~ 1 These drawings and calculations are the property of Monroe & Newell Engineers, Inc. Any use or reproductions of these calculations without the expressed written permission of Monroe & Newell Engineers, Inc. is strictly prohibited. **P.E. stamp on sheet applies to the following calculation pages and indicates that have been reviewed. This includes all sheets attached to this cover. January 10, 2006 10N. 200 Platinum Sponsor me Colorado Chapter of I he American Institute of Architects www.monroe-newell.com 1701 Wynkoop Street * Suite 200 * Denver, Colorado 80202 (303) 623-4927 * FAX (303) 623-6602 * email: denver@monroe-newell.com The Chalets at the Lodge at Vail Building E (M & N #5500.02) Building #3 Calculations See upper floors of Building #2 for Calculations at upper floors of Building #3 PRODUCT 204-1 (Single Sheets) 205-1(Padded) Monroe & Newell Engineers, Inc. JOB SHEET NO. OF_ CALCULATED BY DATE CHECKED BY DATE SCALE I I ' 1 Ih I. I I ~ I u 1 j I I ~ ~ I I I I I 'I 1, i1 I ~ 1 1 ; 1 I 1 , 1 \ 11I I wl w9 r--t~ 1 I i I Z { , IE 'M-II -116- LVL 1~~d0•yy,~~ ii'~~I o~ ~ r~~Il ~ I ( WIOXba ;AI R L - I I_ 1 11 1 Ip ~ i1--~ 1 L- ~~4~ Wig T wlox8e 1 I - (3)-II 7Y LVL7 t1`~ 1 '~C b {a Ir ~ r { f i t 'I I Z ~ ~ 1 I t 410X49 Z'a -4 -4 { I Or Y 91 1 O D= i S-zz d o ' i 410X45 0 I i 1 i t I D= 11 ((gg -i J i i 1 i 'r 1 @ i ~ D I _ I ELI r r i~i• a 1 i { { ! 1 i 1 1 1 ~e I ; 1 I ' i z~ i WIO , Q ' 1 1 yL, _ yt es ~I n I i I I i I I I i I I I I 1 1 I , '1 1 1 1 J 1 1 ~ I I ~ ~a I I _ _ wi xw 'yWr ~ r I I WIOX88 I { I , I r { I ~ ~ r r ~ I I wro ys 0~ I I ~Z ~ { I I WIOX49 - ~ I w~lG 3 iD mo I II 1 1 1 1 , 1 I I i ! Z U i 11 7/$" BGt/450 r i to I -11 7/ WL 1 ~~yPb c r; 1A/ TE/b wiOxbB ~ ~ ~ a ~ ~I~ ~ A I I I iI I 1y I I wiOX4s . u I ! 11 ! 0 I I ! I I I I - J II i 0 I I y Z~ Z~ D Z~ r i r> Or u I r , I i I II I I I ~ o I I 1 I r i I ~ wio ; r I I I ~ - ---_-_r_____---~ 1 L I I , I El ~ Monroe & Newell JOB 15 b 0 Engineers, Inc. SHEET NO. OF A CALCULATED BY C\' DATE ` W CHECKED BY DATE SCALE / N f FLY WOO-p PRODUCT 204-1 (Single Sheets) 705-1 (Padded) A Monroe & Newell Engineers, Inc. 1(Single Sheets) 2g5-1(Padded) JOB V a, l S/an~~r SHEET NO. CALCULATED BY CHECKED BY SCALE OF DATE DATE A Monroe & Newell Engineers, Inc. SHEET NO. OF_ CALCULATED BY DATE CHECKED BY DATE SCALE 4 Monroe & Newell Engineers, Inc. JOB _ G 430O . U °Z SHEET NO. CALCULATED BY `11 CHECKED BY SCALE OF DATE 1Z15f o5 DATE PRODUCT 204-1 (Single Skeels) 205-1 (Padded) v Monroe & Newell Engineers, Inc. SHEET NO. OF I CALCULATED BY t~ DATE l2L `p 0 CHECKED BY DATE 12/e(/2005 03:2i3 3036236602 MONROE NEWELL PAGE 01/02 Monroe & Newell Engineers, Inc. 1701 Wynkoop Street, Suite 200 Denver, Colorado 80202 (303) 623-4927 (303) 623-6602 Fax E-mail: denver®monroe-newel? u,ww- Monroe -newell _ COm Date: Attention: Company: Telephone,; Frorn: S ubj ect: Message; 4 r FACSIMILE TRANSMITTAL LETTER IZ-- ~-Q3~ Pages: (incladitransmittal): M _ - Project m; '575-40 • ~Z' If transmittal is not as indicated please notify sender xxx 2005 P(at;num Sponsor The Colorado Chapter of 'file flmeriann Ingtitutc Of Architects 12/07/2005 09:28 3036236602 Monroe & Newell Engineers, Inc, MONROE NEWELL PAGE 02/02 JOB V Ep ezt6 f j4ta S F~60.0i SHEET NO. _ OF CALCULATED 8Y - DATE 110Z CHECKED BY DATE 4f:Af P i i i ............................j............. i. . Monroe & Newell Engineers, Inc. _....r -7 ~7 5~ao ~oZ SHEET NO. OF CALCULATED BY__ / ~ DATE.. CHECKED BY DATE SCALE 4; 44 ' 4~"1 4 toZ) ~2 t a { l~,v 3v= 3500u ►l oU 'K- 10 Z 00 U (1G0 k 1:0 (n (QOC ji. A Monroe & Newell Engineers, Inc. PRODUCT 204-1 (Single Sheets( 205-1 (Padded) JOB Z SHEET NO. OF CALCULATED BY CHECKED BY SCALE DATE 171 11105 DATE Title : Job # Dsgnr: Date: 2:09PM, 5 DEC 05 Description Scope : User: KW X060365, Ver5.6.1, 25-Oct-2002 Concrete Rectangular & Tee Beam Design Page 2 (c)1983-2002 ENERCALC Enweerinq Software c:\projects\5500.02.ecw:Calculations Description Conc beam at unit 3 bump-out Section Analysis Evaluate Moment Capacity... Center Left End Right End X : Neutral Axis 3.655 in 3.655 in 3.850 in a = beta * Xneutral 2.924 in 2.924 in 3.080 in Compression in Concrete 149.124 k 149.124 k 157.080 k Sum [Steel comp. forces] 210.864 k 210.864 k 262.886 k Tension in Reinforcing -360.000 k -360.000 k -420.000 k Find Max As for Ductile Failure... X-Balanced 40.245 in 40.245 in 40.2449 in Xmax = Xbal * 0.75 30.184 in 30.184 in 30.184 in a-max = beta * Xbal 32.196 in 32.196 in 32.196 in Compression in Concrete 1,231.494 k 1,231.494 k 1,231.494 k Sum [Steel Comp Forces] 334.500 k 334.500 k 390.250 k Total Compressive Force 1,565.994 k 1,565.994 k 1,621.744 k AS Max = Tot Force / Fy 26.100 in2 26.100 in2 27.029 in2 Actual Tension As 6.000 OK 0.000 OK 0.000 OK Additional Deflection Calcs L Neutrai Axis lb.675 in Mcr 623.67 k-ft (gross 592704.00 in4 Ms:Max DL + LL 1,149.05 k-ft Icracked 161965.40 in4 R1 = (Ms:DL+LL)/Mcr 0.543 Elastic Modulus 4,030.5 ksi Ms:Max DL+LL+ST 1,149.05 k-ft Fr = 7.5 * fc^.5 530.330 psi R2 = (Ms:DL+LL+ST)/Mcr 0.543 Z:Cracking 448.685 ksi I:eff... Ms(DL+LL) 230839.865 in4 Z:cracking > 175 : No Good! Leff... Ms(DL+LL+ST) 230839.865 in4 Eff. Flange Width 12.00 in ACI Factors (per ACI, applied internally to entered loads) AGI 9-1 & 9-2 DL 1.40U AGI 9-2 Group Factor 0.750 UBU 1921.2.7 1.4" Factor 1.400 ACI 9-1 & 9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7 "0.9" Factor 0.900 ACI 9-1 & 9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 ....seismic = ST * : 1.100 Title : Dsgnr: Description Scope : User KW-Co0365,Ver 5.6.1, 25-Oct-2002 . Concrete Rectangular & Tee Beam Design (c11983-2002 ENERCALC Enaineerino Software Description Conc beam at unit 3 bump-out General information Span 28A0 tt Depth 84.000 in Width 12.000 in Beam Weight Added Internally LReinforcing Calculations are designed to ACI 318-95 and 1997 UBC Requirements Vc 5,uuu psi Fy 60,000 psi Concrete Wt. 145.0 pef Seismic Zone 1 End Fixity Pinned-Pinned Live Load acts with Short Term Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam... Count Size V from Top Count Size V from Top Count Size V from Top #1 6 9 2.00in #1 6 9 2.00 in #1 7 9 2.00 in #2 6 9 68.00 in #2 6 9 68.00 in #2 7 9 68.00 in Uniform Loads Dead Load Live Load #1 5.610 k 5.100 k Summary Span = 28.00ft, Width= 12.00in Depth = 84.00in Maximum Moment : Mu 1,758.61 k-ft Allowable Moment : Mn`phi 1,786.96 k-ft Maximum Shear: Vu 150.74 k Allowable Shear: Vn'phi 155.89 k Shear Stirrups... Stirrup Area @ Section 0.4 00 in2 Region 0.000 4.667 Max. Spacing 24.000 24.000 Max Vu 150.738 150.738 Short Term k 9.333 24.000 84.413 Beam Design OK -0.1743 in 164.15 k 164.15 k 14.000 18.667 23.333 28.000 ft 24.000 24.000 24.000 24.000 in 82.403 82.403 148.728 148.728 k Bending & Shear Force Summary Bending... Mn*Phi @ Center 1,786.96 k-f @ Left End 1,786.96 k-fl @ Right End 2,083.18 k-fl Shear... Vn*Phi @ Left End 155.89 k @ Right End 155.89 k Deflection Deflections... DL + [Bm Wt] DL + LL + [Bm Wt] DL + LL + ST + [Bm Wt] Reactions... DL + [Bm Wt]] DL + LL + [Bm Wt] DL + LL + ST + [Bm Wt] Maximum Deflection Max Reaction @ Left Max Reaction @ Right Job # Date: 2:09PM. 5 DEC 05 Page 1 c:\oroi ects\5500.02.ecw: Ca Icu lati ons Start End 0.000 ft 28.000 ft Mu, Eq. 9-1 1,758.61 k-ft 0.00 k-ft 0.00 k-ft Vu, Eq. 9-1 150.74 k 148.73 k U pwa rtl 0.0000 in at 28.0000 ft 0.0000 in at 28.0000 ft 0.0000 in at 28.0000 ft Ca). Left 92.750 k 164.150 k 164.150 k Mu, Eq. 9-2 Mu, Eq. 9-3 1,318.96 k-ft 681.71 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft Vu, Eq. 9-2 Vu, Eq. 9-2 113.05 k 58.43 k 111.55 k 57.65 k @ Right 92.750 k 164.150 k 164.150 k uownwara -0.0418 in at 14.0000ft -0.1743 in at 14.0000ft -0.1743 in at 14.0000ft Title : Dsgnr: Description Scope : KW-060365, 25-Oct-2002 (c)14R3-2002ENER ENERCALCEncin EnaineerinanaSo Software Concrete Rectangular & Tee Beam Design Description 8" slab at unit 3 bump-out Job # Date: 5:38PM, 6 DEC 05 Page 1 r,~projects\5500.02.ecw_Ca lculations General Information Calculations are designed to ACI 318-95 and 1997 LIBC Requirements Span i u.uu tt Depth 8 fu 4,000 psi .000 in Width 12.000 it FY 60,000 psi Concrete Wt. 145.0 pcf Seismic Zone 0 End Fixity Pinned-Pinned Beam Weight Added Internally Live Load acts with Short Term Reinforcing Rebar @ Center of Beam... Rebar @ Left End of Beam... Rebar @ Right End of Beam... Count Size 'd' from Top Count Size 'd' from Top Count Size 'd' from Top #1 3 6 6:00in #1 in #1 in ~Un fom oads ✓ wT Dead Load Live Load Short Term Start End #1 0.350 k 0.100 k k 2.500 ft 10.000 ft Concentrated Loads Dead Load Live Load Short Term Location #1 2.500 k 2.500 k k 2.500 ft Summary Beam Design OK Span = 10.00ft, Width= 12.00in Depth = 8.00in Maximum Moment : Mu 20.48 k-ft Allowable Moment : Mn*phi 29.85 k-ft Maximum Deflection -0.3087 in Maximum Shear: Vu 8.28 k Max Reaction @ Left 5.50 k Allowable Shear: Vn*phi 38.71 k Max Reaction @ Right 3.84 k Shear Stirrups... Stirrup Area @ Section 0.440 in2 i Region 0.000 1.667 Max. Spacing 3.000 3.000 3.333 5.000 6.667 8.333 10.000 ft Not Req'd Not Req'd Not Re 'd 3 000 3 0 Max Vu 8.280 8.123 q . . 00 in 0.395 0.395 3.036 4.372 5.294 k Bending & Shear Force Summary Bending... Mn Phi Mu, Eq. 9-1 Mu, Eq. 9-2 Mu Eq 9-3 @ Center 29.85 k -ft , . 20.48 k-ft 15.36 k-ft 7 61 k-ft @ Left End 0.00 k-ft @ Right End 0 00 k ft . 0.00 k-ft 0.00 k-ft 0.00 k-ft . - -0.00 k-ft -0.00 k-ft -0 00 k-ft Shear... Vn*Phi . Vu, Eq. 9-1 Vu, Eq. 9-2 Vu Eq 9-3 @ Left End 38.71 k , . 8.28 k 6.21 k 2 97 k @ Right End 38.71 k . 5.29 k 3.97 k 2.27 k Deflection Deflections... upward DL + [Bm Wt] 0.0000 in Downwaro at 0.0000 ft -0.1608 in at 4 8000ft DL + LL + [Bm Wt] 0.0000 in . at 0.0000 ft -0.3087 in at 4 7200ft DL + LL + ST + [Bm Wt] 0.0000 in . at 0.0000 ft -0.3086 in at 4.7200ft Reactions... Ca Left (aD Right DL + [Bm Wt]] 3.343 k 2.749 k DL + LL + [Bm Wt] 5.499 k 3.843 k DL + LL + ST + [Bm Wt] 5.499 k 3.843 k Title : Dsgnr: Description Scope : KW-060365, 2 Concrete Rectangular & Tee Beare Design (c)1199833--220022 ENERCAI C Engineering Software Description 8" slab at unit 3 bump-out Job # Date: 5:38PM, 6 DEC 05 Page 2 c9nrniects'S500. 02. ecw Calculations j Section Analysis - Evaluate Moment Capacity... Center Left End Right End X : Neutral Axis 2.280 in 0.000 in 0 000 in a = beta ' Xneutral 1.938 in 0.000 in . 0 000 in Compression in Concrete 79.070 k 0.000 k . 0.000 k Sum [Steel comp. forces] 0.000 k 0.000 k 0.000 k Tension in Reinforcing -79.200 k 0.000 k 0.000 k Find Max As for Ductile Failure... X-Balanced 3.551 in 0.000 in 0 0000 in Xmax = Xbal ' 0.75 2.663 in 0.000 in . 0.000 in a-max = beta ' Xbal 3.018 in 0.000 in 0.000 in Compression in Concrete 92.362 k 0.000 k 0 000 k Sum [Steel Comp Forces] 0.000 k 0.000 k . 0.000 k Total Compressive Force 92.362 k 0.000 k 0.000 k AS Max = Tot Force / Fy 1.539 in2 0.000 in2 0.000 in2 Actual Tension As 1.320 OK 0.000 OK 0.000 OK Additional Deflection Calcs Neutral Axis 2.495 in Mcr 5.06 k-ft (gross 512.00 in4 Ms:Max DL + LL 13 50 k-ft Icracked 192.58 in4 R1 = (Ms:DL+LL)/Mcr . 0.375 Elastic Modulus 3,605.0 ksi Ms:Max DL+LL+ST 13.50 k-ft Fr = 7.5 - fc^.5 474.342 psi R2 = (Ms:DL+LL+ST)/Mcr 0.375 Z:Cracking 111.193 ksi Leff... Ms(DL+LL) 209.379 in4 Leff Ms(DL+LL+ST) 209.394 in4 Eff. Flange Width 12.00 in ACI Factors (per ACI, applied internally to entered loads) ACI 9-1 & 9-2 DL 1.4uu Aci 9-2 Group Factor u.l5u UBU 1921.2.7 "1.4" Factor 1.400 ACI 9-1 & 9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 LIBC 1921.2.7 "0.9" Factor 0 900 ACI 9-1 & 9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 . ....seismic = ST ' : 1.100 Title : Job # Dsgnr: Date: 5:37PM, 6 DEC 05 Description [ Scope Rev: 560100 --r UserKw-060365,Z5.6.1,25-0ct-2002 Concrete Rectangular & Tee Beam Design Page 1 /r 119A3-20m ENERCALC E i ` . n9 n..nn, Sofhvare c:\nroiects\5500.02. ervrCa1nulations Description 8" slab at unit 3 bump-out i General Information Calculations are designed to ACI 318-95 and 1997 UBC Requirements span 10.00 tt a 4,000 psi Depth 8.000 in Fy 60,000 psi Width 12.000 in Concrete Wt. 145.0 pcf Seismic Zone 0 End Fixity Pinned-Pinned Beam Weight Added Internally Live Load acts with Short Term Reinforcing Rebar @ Center of Beam... 'Rebar @ Left End of Beam... Rebar @ Right End of Beam... Count Size 'd' from Top Count Size 'd' from Top Count Size 'd' from Top #1 3 6 6_00in #1 in #1 in Uniform Loads Dead Load Live Load Short Term Start End #1 0.350 k 0.100 k k 4.000 ft 10.000 ft Concentrated Loads Dead Load Live Load Short Term Location #1 2.500 k 2.500 k k 4.000 ft Summary Beam Design ®K Span = 10.00ft, Width= 12.00in Depth = 8.00in Maximum Moment: Mu 24.98 k-ft l Allowable Moment : Mn'phi 29.85 k-ft Maximum Deflection -0.3549 in Maximum Shear: Vu , 6.45 k Max Reaction @ Left 4.29 k Allowable Shear: Vn*phi 38.71 k Max Reaction @ Right 4.37 k Shear Stirrups... Stirrup Area @ Section 0.440 in2 Re gion0.000 1:667 3.333 5.000 6.667 8.333 10.000 ft E! x. Spacing 3.000 3.000 3.000 3.000 3.000 3.000 3.000 in x Vu 6.450 6.293 6.065 3.876 3.876 5.213 6.135 k Bending & Shear Force Summary Bending... Mn*Phi Mu, Eq. 9-1 Mu, Eq. 9-2 Mu, Eq. 9-3 @ Center 29.85 k-ft 24.98 k-ft 18.73 k-ft 8.71 k-ft @ Left End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft @ Right End 0.00 k-ft 0.00 k-ft 0.00 k-ft 0.00 k-ft Shear... Vn*Phi Vu, Eq. 9-1 Vu, Eq. 9-2 Vu, Eq. 9-3 @ Left End 38.71 k 6.45 k 4.84 k 2.31 k @ Right End 38.71 k 6.14 k 4.60 k 2.45 k LDeflection Deflections... Upwaru Upwnwafu DL + [Bm Wt] 0.0000 in at 0.0000 ft -0.1846 in at 4.9200ft DL + LL + [Bm Wt] 0.0000 in at 0.0000 ft -0.3549 in at 4.8800ft DL + LL + ST + [Bm Wt] 0.0000 in at 0.0000 ft -0.3549 in at 4.8800ft Reactions... (a Left a Right DL + [Bm Wt]] 2.613 k 2.953 k DL + LL + [Bm Wt] 4.293 k 4.373 k DL + LL + ST + [Bm Wt] 4.293 k 4.373 k Title : Dsgnr: Description Scope Rev: 560100 Rectangular User KW-060365, Ver 525-Oct-2002 L (c)19833--2002 2002 ENERC NERCALC Enoineerino nc Software E Concrete & Tee Beam Design Description 8" slab at unit 3 bump-out Job # Date: 5.37PM, 6 DEC 05 Page 2 c:\oroi ects\5500.02. ecw:Ca lcu l a tlon s 5ection Analysis Evaluate Moment Capacity... Center X : Neutral Axis 2.280 in a = beta * Xneutral 1.938 in Compression in Concrete 79.070 k Sum [Steel comp. forces] 0.000 k Tension in Reinforcing -79.200 k Find Max As for Ductile Failure... X-Balanced 3.551 in Xmax = Xbal ' 0.75 2.663 in a-max = beta ' Xbal 3.018 in Compression in Concrete 92.362 k Sum [Steel Comp Forces] 0.000 k Total Compressive Force 92.362 k AS Max = Tot Force / Fy 1.539 in2 Actual Tension As 1.320 OK Additional Deflection Calcs Left End 0.000 in 0.000 in 0.000 k 0.000 k 0.000 k 0.000 in 0.000 in 0.000 in 0.000 k 0.000 k 0.000 k 0.000 in2 0.000 OK Riqht End 0.000 in 0.000 in 0.000 k 0.000 k 0.000 k 0.0000 in 0.000 in 0.000 in 0.000 k 0.000 k 0.000 k 0.000 in2 0.000 OK eutral Axis 2.495 in Mcr 5.06 k-ft Igross 512.00 in4 Ms:Max DL + LL 16 40 k-ft Icracked 192.58 in4 R1 = (Ms:DL+LL)/Mcr . 0 309 Elastic Modulus 3,605.0 ksi Ms:Max DL+LL+ST . 16.40 k-ft Fr = 7.5 ' Pc^.5 474.342 psi R2 = (Ms:DL+LL+ST)/Mcr 0,309 Z:Cracking 135.045 ksi Leff... Ms(DL+LL) 201.955 in4 I:efi... Ms(DL+LL+ST) 201.955 in4 Eff. Flange Width 12.00 in ACI Factors (per ACI , applied internally to entered loads) ACI 9-1 & 9-2 DL 1.400 ACI 9-2 Group Factor U./5u uBG 1Y21.2.7 1.4" Factor 1 400e_ ACI 9-1 & 9-2 LL 1.700 ACI 9-3 Dead Load Factor 0.900 . UBC 1921.2.7 "0.9" Factor 0 900 ACI 9-1 & 9-2 ST 1.700 ACI 9-3 Short Term Factor 1.300 . ....seismic = ST ' : 1.100 Title : Job # Dsgnr: Date: 5:29PM, 6 DEC 05 Description Scope 'Rev: 560100 User: KW-0 60365, Ver 5.5.1, 25-0ct-2002 Page 1 (c2002ENERCALCEngineeringSoftware oncrete Rectangular & Tee Beam Design c~~rojectsl5500.02.ecw:Calculations Description ConC beam at unit 3 bump-out General Information Calculations are designed to ACI 318-95 and 1997 UBC Requirements Span Zd.uu tt t'c ,,UVU psi Depth 32.000 in Fy 60,000 psi Width 18.000 in Concrete Wt. 145.0 pcf Flange @ One Side Flange Thickness 8.000 in Seismic Zone 1 Web Spacing 8.000 ft End Fixity Fixed-Fixed Tee beam weight calc'd u sing Depth ' Width Live Load acts with Short Term Reinforcing Rebar @ Center of Beam.,. Rebar @ Left End of Beam... Rebar'@ Right End of Beam... Count Size 'd' from Top Count Size 'd' from Top Count Size 'd' from Top #1 6 9 2.00in #1 8 9 2.00 in #1 8 9 2.00 in #2 6 9 28.00 in #2 8 9 28.00 in #2 8 9 28.00 in Uniform Loads Dead Load Live Load Short Term Start End #1 4.000 k 4.000 k k 0.000 ft 28.000 ft Summary Beam Design OK Span = 28.00ft, Width= 18.00in Dept h = 32.00in 'T' Beam with Flange= 8.00in thick @ One Side, Web spac= 8.00ft Maximum Moment : Mu -863.18 k-ft Maximum Deflection -0 1828 in Allowable Moment.: Mn"phi 978.25 k-ft . Maximum Shear: Vu 152.41 k Max Reaction @ Left 120.12 k Allowable Shear: Vn'phi 152.41 k Max Reaction @ Right 120.12 k Shear Stirrups... Stirrup Area @ Section 0.400 in2 Region 0.000 4.667 9.333 14.000 18.667 23.333 28.000 ft Max. Spacing 6.220 7.000 14.000 14.000 14.000 7.000 6.322 in Max Vu 152.414 124.298 62.149 60.669 60.669 122.819 150.934 k Bending & Shear Force Summary Bending... Mn•Phi Mu, Eq. 9-1 . Mu, Eq. 9-2 Mu, Eq. 9-3 @ Center 729.91 k-ft 431.59 k-ft 323.69 k-ft 157.09 k-ft @ Left End 978.25 k-ft -863.18 k-ft -647.39 k-ft -314.19 k-ft @ Right End 978.25 k-ft -863.18 k-ft -647.39 k-ft -314.19 k-ft Shear... Vn'Phi Vu, Eq. 9-1 Vu, Eq. 9-2 Vu, Eq. 9-2 @. Left End 152.41 k 152.41 k 114.31 k 55.48 k @ Right End 150.93 k 150.93 k 113.20 k 54.94 k Deflection Deflections... DL + [Bm Wt] DL + LL + [Bm Wt] DL + LL + ST + [Bm Wt] Reactions... DL + [Bm Wt]] DL + LL + [Bm Wt] DL+LL+ST+[Bm Wt] uowara 0.0000 in at 0.0000 ft 0.0000 in at 0.0000 ft 0.0000 in at 0.0000 ft Car Left (a) Right 64.120 k 64.120 k 120.120 k 120.120 k 120.120 k 120.120 k bum maw -0.0815 in at 14.0000ft -0.1828 in at 14.0000ft -0.1828 in at 14.0000ft Title : Dsgnr: Description Scope : L cser: K W0020E 5, Ver5C E, 25-Ocino0$oftware Concrete Rectangular & Tee Beam Design Description Conc beam at unit 3 bump-out Job # Date: 5:29PM, 6 DEC 05 Page 2 r\nrniecfs\550n Q7 erw'Calrulatinrts LSection Analysis Evaluate Moment Capacity... Center Left End Right End X : Neutral Axis 2.185 in 5.420 in 5.420 in a = beta * Xn.eutral 1.748 in 4.336 in 4.336 in Compression in Concrete 133.722 k 331.704 k 331.704 k Sum [Steel comp. forces] 18.697 k 148.347 k 148.347 k Tension in Reinforcing -360.000 k -480.000 k -480.000 k Find Max As for Ductile Failure... X-Balanced 16.571 in 17.755 in 17.7551 in Xmax = Xbal * 0.75 12.429 in 13.316 in 13.316 in a-max = beta * Xbal 13.257 in 14.204 in 14.204 in Compression in Concrete 1,712.629 k 814.959 k 814.959 k Sum [Steel Comp Forces] 334.500 k 446.000 k 446.000 k Total Compressive Force 2,047.129 k 1,260.959 k 1,260.959 k AS Max = Tot Force / Fy 34.119 in2 21.016 in2 21.016 in2 Actual Tension As 6.000 OK 8.00.0 OK 8.000 OK Additional Deflection Calcs Neutral Axis 5.860 in Mcr 167.94 k-ft (gross 73,570.99 in4 Ms:Max DL + LL 560.56 k-ft Icracked 31,066.35 in4 R1 = (Ms:DL+LL)/Mcr 0.300 Elastic Modulus 4,030.5 ksi Ms:Max DL+LL+ST 560.56 k-ft Fr = 7.5 * Pc^.5 530.330 psi R2 = (Ms:DL+LL+ST)/Mcr 0.300 Z:Cracking 231.863 ksi Leff... Ms(DL+LL) ' 32,209.415 in4 Z:cracking > 175: No Good! Leff... Ms(DL+LL+ST) 32,209.415 in4 Eff. Flange Width ACI Factors (per ACI, applied ini ACI 9-1 & 9-2 DL 1.400 ACI 9-1 & 9-2 LL 1.700 ACI 9-1 & 9-2 ST 1.700 ....seismic = ST 1.100 46.00 in ernally to entered loads) ACI 9-2 Group Factor 0.750 UBC 1921.2.7 "1.4" Factor 1.400 ACI 9-3 Dead Load Factor 0.900 UBC 1921.2.7 "0.9" Factor 0.900 ACI 9-3 Short Term Factor 1.300 The Chalets at the Lodge at Vail Building E (M & N #5500.02) Building #4 Calculations See Building #2 for Calculations of Building #4 The Chalets at the Lodge at Vail . Building E (M & N #5500.02) Building #5 Calculations See upper floors of Building #2 for Calculations at upper floors of Building #5 Monroe & Newell Engineers, Inc. JOB SHEET NO. CALCULATED BY CHECKED BY SCALE OF DATE I ~-7 I DATE ~ F~.~ t :...ate .../.J'. 1 F--./.,i . bL -TL 1 V, ` L L. t r _ ; j i PRODUCT 2044 (Single Sheets) 205-1 (Padded) Monroe & Newell Engineers, Inc. PRODUCT 204-1 (Single Sheets) 205-1(Padded) JOB SHEET NO. CALCULATED BY. CHECKED BY_ SCALE OF_ DATE DATE r ~ `V U3 'Z - ~0 a 3 pot r I~ 1h'l ~IL II- C i R 1 Monroe & Newell JOB i Engineers, Inc. SHEET NO. OF } DATE a CALCULATED BY DATE CHECKED BY SCALE m,. GL +I e LVID _ YY" 1 7 /n FYI - 1 41- ,v E- K - - G ri f- 2 I gy=p 4, X120 e 1-7 /i 7a- JOB s~ Monroe & Newell OF Engineers, Inc. SHEET NO. A CALCULATED BY DATE 1 105 CHECKED BY DATE SCALE L!~ (P~ acY.r- t t E ~Cr o4 MOP, s_~.- . i Monroe & Newell JOB - OF Engineers, Inc. SHEET NO. CALCULATED BY DATE DATE CHECKED BY SCALE . ! j l r l a _ t _(ft 1~y T i ! / `l Monroe & Newell JOB Engineers, Inc. SHEET NO. OF 1 - DATE a ^ CALCULATED BY DATE CHECKED BY SCALE r D~ 5 5 ic, a r , i c u p - /vv y JOB \ \ ° 2c::z "'d~, =i• - I 'y`~, t; 1 Monroe & Newell ~y Engineers, Inc. SHEET NO. 1a of CALCULATED BY DATE e i CHECKED BY DATE SCALE ~r U- L. ~ F 1 Monroe & Newell Engineers, Inc. SHEET NO. ~ of )t A _ CALCULATED BY DATE CHECKED BY DATE SCALE '1-5 l I ~ ~.ra { I .1 PRODUCT 2D4-1 (Single Sheets) 205-1(Padded) JOB Monroe & Newell v Engineers, Inc. SHEET NO. c of A CALCULATED BY ` ,L 1~ DATE I ' CHECKED BY DATE SCALE t(P L'sEr 22 ' JOB 1 J i l Monroe & Newell OF Engineers, Inc. SHEET NO. A CALCULATED BY DATE CHECKED BY DATE SCALE 9 -7' g Title : 24F - V8 Dsgnr: Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software amm Description Bm #1 Steel Beam Design General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 1 Steel Section : W10X22 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 5.50 ft Bm Wt. Added to Loads Elastic Modulus 29,000.Oksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 DL 1.300 0.600 k/ft LL 1.120 0.560 k/ft ST k/ft Start Location 1.500 ft End Location 1.500 5.500 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 Dead Load 1.980 1.980 k Live Load 1.820 1.820 k Short Term k Location 1.500 5.000 ft Summary Using: W 10X22 section, Span = 5.50ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Allowable Moment 9.359 k-ft 63.800 k-ft fb : Bending Stress 4.841 ksi 33.000 ksi fb/Fb 0.147:1 Dougl Job # Date: 6:58AM, 16 JAN 06 s 153, Lkft' .p 56 Page 1 5b 153.ecw:Calculations Beam OK Static Load Case Governs Stress Max. Deflection -0.015 in Length/DL Defl 8,296.6: 1 Length/(DL+LL' Defl) 4,367.8: 1 Shear 7.999 k 48.816 k fv : Shear Stress 3.277 ksi 20.000 ksi fv / Fv 0.164 :1 Shear @ Left 7.99 k 4.24 7.99 k Shear @ Right 8.00 k 4.19 8.00 k Center Defl. -0.015 in -0.008 -0.015 -0.015 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 7.99 4.24 7.99 7.99 k Reaction @ Rt 8.00 4.19 8.00 8.00 k Fa calc'd per Eq. E2-1, K"L/r < Cc I Beam Passes Table B5.1, Fb per Eq, F1-1, Fb = 0.66 Fy Title : 24F-V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description Jc a5 3 Scope : Rev: 580006 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 2 (c)1983-2003 ENEACALC Engineering Software 5b 153.ecw:Calculations Description Bm #1 Section Properties W10X22 ti Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 Cw 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description Scope : v t~~ Ver 5.8.0. 1 Steel Beam Design Page 1 5b 153.ecw:Calculations (c)1983-2003 ENERCALC Engineering Sc Description Bm #2 General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X22 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 6.25 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 DL 1.300 k/ft LL 1.120 k/ft ST k/ft Start Location ft End Location 6.250 ft noummary A Beam OK 2 Static Load Case Governs Stress Using: W 10X22 section, Span = 6.25ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Allowable Moment 11.924 k-ft 63.800 k-ft Max. Deflection -0.024 in fb.: Bending Stress 6.168 ksi 33.000 ksi Length/DL Defl 5,654.6 : 1 fb / Fb 0.187 : 1 Length/(DL+LL Defl) 3,061.2: 1 Shear 7.631 k 48.816 k fv : Shear Stress 3.127 ksi 20.000 ksi fv / Fv 0.156 : 1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 11.92 k-ft 6.46 11.92 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 7.63 k 4.13 7.63 k Shear @ Right 7.63 k 4.13 7.63 k Center Defl. -0.024 in -0.013 -0.024 -0.024 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 7.63 4.13 7.63 7.63 k Reaction @ Rt 7.63 4.13 7.63 7.63 k Fa calc'd per Eq. E2-1, K'L/r < Cc I Beam Passes Table B5.1, Fb per Eq. F 1-1, Fb = 0.66 Fy Title : 24F - V8 Dsgnr: Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #2 Steel Beam Design Dougl Job # Date: 6:58AM, 16 JAN 06 yr:op- 65,00-Oz SI!5g Page 2 i 5b 153.ecw:Calculations Section Properties W10X22 Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 Cw 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : VFP Scope : L~e.l 580006 Pa ge 1 : KW0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design L983-2003 ENERCALC Engineering Software 5b 153.ecw:Calcu1ations Description Bm #3 General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : WlOX22 l Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 7.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 DL 0.940 0.600 k/ft LL 1.120 0.560 k/ft ST k/ft Start Location 2.670 ft End Location 2.670 7.000 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 Dead Load 1.980 1.980 2.400 k Live Load 1.820 1.820 3.100 k Short Term k Location 2.670 6.000 4.670 ft Summary Using: W1 OX22 section, Span = 7. 00ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Moment 22.316 k-ft fb : Bending Stress 11.543 ksi fb / Fb 0.350 : 1 Shear 12.971 k fv : Shear Stress 5.314 ksi fv / Fv 0.266 : 1 Beam OK Static Load Case Governs Stress Allowable 63.800 k-ft Max. Deflection -0.058 in 33.000 ksi Length/DL Defl 2,951.8 :1 Length/(DL+LL Defl) 1,438.1 :1 48.816 k 20.000 ksi Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 22.32 k-ft 10.86 22.32 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 10.81 k 5.22 10.81 k Shear @ Right 12.97 k 6.40 12.97 k Center Defl. -0.058 in -0.028 -0.058 -0.058 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 10.81 5.22 10.81 10.81 k Reaction @ Rt 12.97 6.40 12.97 12.97 k Fa caldd per Eq. E2-1, K'L/r < Cc I Beam Passes Table B5.1, Fb per Eq. F1-1, Fb = 0.66 Fy Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : nev: otmuo User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #3 Steel Beam Design Page 2 5b 153.ecw:Calculations Section Properties W1OX22 Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 CW 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F -V8 Doug[ Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Description Bm #4 Steel Beam Design General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X26 y s! Pinned-Pinned Load Duration Factor 1.00 Center Span 6.83 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 it Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. ~ . #1 #2 #3 #4 #5 #6 #7 DL 0.940 0.470 0.940 k/ft LL 1.120 0.560 1.120 k/ft ST k/ft Start Location 2.000 5.330 ft End Location 2.000 5.330 6.830 ft Point Loads Dead Load Live Load Short Term Location #2 1.200 2.700 1.600 4.700 #3 #4 13.300 2.400 36.900 3.100 1.500 2.000 5.330 3.170 Note! Short Term Loads Are WIND Loads. #5 #6 #7 k k k it Summary Beam OK Static Load Case Governs Stress Using: W1 OX26 section, Span = 6.83ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Allowable Moment 72.333 k-ft 76.725 k-ft Max. Deflection -0.137 in fb : Bending Stress 31.111 ksi 33.000 ksi Length/DL Defl 1,844.3 :1 fb / Fb 0.943:1 Length/(DL+LL Defl) 597.6 :1 Shear 49.792 k 53.716 k fv : Shear Stress 18.539 ksi 20.000 ksi fv / Fv 0.927 : 1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 72.33 k-ft 21.49 72.33 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 26.92 k 9.63 26.92 k Shear @ Right 49.79 k 15.01 49.79 k Center Defl. -0.137 in -0.044 -0.137 -0.137 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 26.92 9.63 26.92 26.92 k Reaction @ Rt 49.79 15.01 49.79 49.79 k Fa caldd per Eq. E2-1, K'L/r < Cc I Beam Passes Table 35.1, Fb per Eq. F 1-1, Fb = 0.66 Fy Page 1 5b 153.ecw:Calculations Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580006 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Steel Beam Design Page 2 (c)1983.2003 ENERCALC Engineering Software 5b 153,ecw:Calculations Description Bm #4 Section Properties W1OX26 Depth 10.330 in Weight 25.85 #/ft Web Thick 0.260 in Ixx 144.000 in4 Width 5.770 in lyy 14.100 in4 Flange Thick 0.440 in Sxx 27.900 in3 Area 7.61 in2 Syy 4.890 in3 Rt 1.540 in R-xx 4.350 in Values for LRFD Design.... R-yy 1.360 in J 0.400 in4 Zx 31.300 in3 CW 345.00 in6 Zy 7.500 in3 K 0.660 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Description Bm #4.1 General Timber Beam Page 1 5b 153.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam:3.5x11.875 Center Span 5.50 ft .....Lu 5.50 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Point Loads Dead Load 540.0 lbs Ibs Live Load 200.0 Ibs Ibs ...distance 1.670 ft 0.000 ft - A_-r= Ibs Ibs Ibs Ibs Ibs Ibs Ibs Ibs Ibs Ibs 0.000 ft 0.000 It 0.000 ft 0.000 ft 0.000 ft Beam Design OK Span= 5.50ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.068 : 1 Maximum Moment 0.9 k-ft Maximum Shear * 1.5 0.8 k .Allowable 17.5 k-ft Allowable 11.8 k Max. Positive Moment 0.89 k-ft at 1.672 ft Shear: @ Left 0.54 k Max. Negative Moment 0.00 k-ft at 5.500 ft @ Right 0.25 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.005in Max. M allow 17.47 Reactions... @ Right 0.000 in fb 130.19 psi fv 19.25 psi Left DL 0.40 k Max 0.54 k Fb 2,547.91 psi Fv 285.00 psi Right DL 0:19 k Max 0.25 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.003 in -0.004 in Deflection 0.000 in 0.000 in ...Location 2.486 ft 2.486 ft ...Length/Deft 0.0 0.0 ...Length/Deft 21,710.0 16,160.91 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.005 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Y Ck 21.924 Le 11.325 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 11.480 Cl 0.980 Max Moment Sxx Req'd Allowable fb @ Center 0.89 k-ft 4.20 in3 2,547.91 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 0.80 k 0.36 k Area Required 2.807 in2 1.277 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 0.54 k Bearing Length Req'd 0.207 in Max. Right Reaction 0.25 k Bearing Length Req'd 0.096 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver 5.8.0 (c)1983-2003 ENERCALC En Description Bm #4.1 General Timber Beam Page 2 5b 153.ecw:Calculalions Query Values - M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 0.54 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : 24F - V8 Dsgnr: Description Scope : (c)1983-2003 ENERCALC Engineering Sc Description Bm #5 Steel Beam Design Dougl Job # Date: 6:58AM, 16 JAN 06 Page 1 5b 153.ecw:Calculations General Information Code Ref: RISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : WlOX22 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 5.83 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. .?7 #1 #2 #3 #4 #5 #6 #7 DL 0.705 k/ft LL 1.515 k/ft ST k/ft Start Location ft End Location 5.830 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 _-#3 #4 #5 #6 #7 Dead Load 0.400 k Live Load 0.200 k Short Term k Location 0.500 ft Summary Using: W1 OX22 section, Span = 5.83ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Allowable Moment 9.676 k-ft 63.800 k-ft fb : Bending Stress 5.005 ksi 33.000 ksi fb / Fb 0.152 : 1 Shear 7.084 k 48.816 k fv : Shear Stress 2.902 ksi 20.000 ksi fv / Fv 0.145 : 1 Beam OK Static Load Case Governs Stress Max. Deflection -0.017 in Length/DL Defl 12,198.9 :1 Length/(DL+LL Defl) 4,032.6 :1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 9.68 k-ft 3.19 9.68 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 7.08 k 2.49 7.08 k Shear @ Right 6.59 k 2.15 6.59 k Center Defl. -0.017 in -0.006 -0.017 -0.017 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 7.08 2.49 7.08 7.08 k Reaction @ Rt 6.59 2.15 6.59 6.59 k Fa caldd per Eq. E2-1, K*Ur < Cc I Beam Passes Table B5.1, Fb per Eq. F 1-1, Fb = 0.66 FV Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : !v: bbuuub er: KW-0606238, Ver 5.8.0, 1-Dec-2003 1983-2003 ENERCALC Engineering Software Description Steel Beam Design Bm #5 Page 2 5b 153.ecw:Calculations MET- :1 ji - Section Properties W1OX22 t Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 CW 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F - V8 Dsgnr: Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software 111 0 Description Bm #6 General Timber Beam Page 1 5b 153.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name Micro Lam: 3.5x11.875 Beam Width 3.500 in Beam Depth 11.875 in Member Type Manuf/So.Pine Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000 pcf Full Length Uniform Loads Center DL Left Cantilever DL Right Cantilever DL Center Span 4.00 ft .....Lu Left Cantilever ft .....Lu Right Cantilever ft .....Lu Truss Joist - MacMillan, MicroLam 1.9 E Fb Base Allow 2,600.0 psi Fv Allow 285.0 psi Fc Allow 750.0 psi E 1,900.0 ksi 345.00 #/ft LL 325.00 #/ft #/ft LL #/ft #/ft LL #/ft 5.50 ft 0.00 ft 0.00 ft Beam Design OK Span= 4.00ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0088 : 1 " 0 k 1 4 k-ft 1 Maximum Shear 1.5 . Maximum Moment . 5 k-ft 17 Allowable 11.8 k Allowable . Max. Positive Moment 1.36 k-ft at 2.000 ft Shear: @ Left @ Right 1.36 k 1.36 k Max. Negative Moment 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.003in 000 in 0 @ Right . Max. M allow 17.47 Reactions... fb 198.43 psi fv 25.13 psi Left DL 0.71 k Max 1.36 k Fb 2,547.91 psi Fv 285.00 psi Right DL 0.71 k Max 1.36 k Deflections Center Span... Dead Load Total Load ever... an Le Deflection -0.002 in -0.004 in Deflection ...Location 2.000 ft 2.000 ft ...Length/Deft ...Length/Deft 21,778.0 11,370.96 Right Cantilever... Camber ( using 1.5 * D.L. DO ) Deflection @ Center 0.003 in nPari I Hari Total Load til ft C ...Length/Dell @ Left @ Right 0.000 in 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 11.325 ft Sxx 82.259 in3 Cf 1.000 Rb 11.480 Cl 0.980 Max Moment Sxx Reo'd @ Center 1.36 k-ft 6.41 in3 @ Left Support 0.00 k-ft 0.00 in3 @ Right Support 0.00 k-ft 0.00 1n3 Shear Analysis @ Left Support @ Right Support Design Shear 1.04 k 1.04 k Area Required 3.665 in2 3.665 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction Max. Right Reaction 1.36 k Req'd 1.36 k Bearing Length Bearing Length Req'd Dougl Job # Date: 6:58AM, 16 JAN 06 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 Area 41.563 in2 Allowable fb 2,547.91 psi 2,600.00 psi 2,600.00 psi 0.518 in 0.518 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580004 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software General Timber Beam Page 2 5b 153.ecw:Calculations Description Bm #6 (query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.36 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : 24F-V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580004 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (01983-2003 ENERCALC Engineering Software Description Bm #7 y General Timber Beam Page 1 5b 153.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name Micro Lam: 3.5xl 1.875 Center Span 4.00 ft .....Lu 5.50 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Trapezoidal Loads #1 DL @ Left 710.00 #/ft LL @ Left 810.00 #/ft Start Loc 0.000 ft DL @ Right 710.00 #/ft LL @ Right 810.00 #/ft End Loc 1.250 ft #2 DL (6 Left 355.00 Wit LL @ Left 405.00 #/ft Start Loc 1.250 ft DL @ Right 355.00 #/ft LL @ Right 405.00 #/ft End Loc 4.000 ft Point Loads Dead Load 540.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs Live Load 200.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 1.250 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft Beam Design OK Span= 4.00ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.172 : 1 Maximum Moment 2.4 k-ft Maximum Shear * 1.5 2.0 k Allowable 17.5 k-ft Allowable 11.8 k Max. Positive Moment 2.39 k-ft at 1.504 ft Shear: @ Left 2.85 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 1.92 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.006in Max. M allow 17.47 Reactions... @ Right 0.000in fb 349.12 psi fv 48.98 psi Left DL 1.48 k Max 2.85 k Fb 2,547.91 psi Fv 285.00 psi Right DL 0.97 k Max 1.92 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.004 in -0.007 in Deflection 0.000 in 0.000 in ...Location 1.920 ft 1.920 ft ...Length/Deft 0.0 0.0 ...Length/Dell 12,465.2 6,554.00 Right Cantilever... Camber ( using 1.5 x D.L. Dell ) Deflection 0.000 in 0.000 in @ Center 0.006 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : rev: 5tluuva User: KW-06( (c)1983.2003 General Timber Beam Page 2 5b 153.ecw:Calculations Description Bm #7 Stress Calcs Bending Analysis Ck 21.924 Le 11.325 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 11.480 Cl 0.980 Max Moment Sxx Read Allowable fb @ Center 2.39 k-ft 11.27 in3 2,547.91 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 2.04 k 1.75 k Area Required 7.143 in2 6.149 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 2.85 k Bearing Length Req'd 1.086 in Max. Right Reaction 1.92 k Bearing Length Req'd 0.731 in Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 2.85 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Hev:56oo06 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983-2003 ENERCALC Engineering Software 5b 153.ecw:Ca1cu1aticns Description Bm #8 General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X22 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 11.50 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 2.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 DL 0.320 0.690 0.320 k/ft LL 0.425 0.625 0.425 k/ft ST k/ft Start Location 3.000 8.670 ft End Location 3.000 8.670 11.500 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 Dead Load 2.300 2.300 1.400 Live Load 2.600 2.600 1.600 Short Term Location 3.000 8.670 9.670 #6 # k k k ft Summary Using: W 10X22 section, Span= 11.50ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 2.00ft, LDF = 1.000 Actual Allowable Moment 36.777 k-ft 63.800 k-ft fb : Bending Stress 19.022 ksi 33.000 ksi fb / Fb 0.576 : 1 Shear 13.545 k 48.816 k fv : Shear Stress 5.550 ksi 20.000 ksi fv / Fv 0.277 : 1 Beam OK Static Load Case Governs Stress Max. Deflection -0.266 in Length/DL Defl 1,054.9 :1 Length/(DL+LL Defl) 519.7 :1 Force & Stress Summary <<-= These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 36.78 k-ft 18.21 36.78 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 11.31 k 5.49 11.31 k Shear @ Right 13.55 k 6.54 13.55 k Center Defl. -0.266 in -0.131 -0.266 -0.266 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 11.31 5.49 11.31 11.31 k Reaction @ Rt 13.55 6.54 13.55 13.55 k Fa calc'd per Eq. E2-1, K"Ur < Cc I Beam Passes Table B5.1, Fb per Eq. F1-1, Fb = 0.66 Fy Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : 1983-2003 Description Ver5.8.0, 1-Dec-2003 Steel Beam Design CALC Engineering Software Bm #8 Page 2 5b 153.ecw:Calculations Section Properties W1OX22 Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 Cw 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F-V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Enaineering Software Description Bm #9 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Center Span 8.00 ft .....Lu 8.00 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0 ksi Full Length Uniform Loads Center DL 135.00 #/ft LL 180.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Beam Design OK Span= 8.00ft, Beam Wi Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support General Timber Beam Page 1 5b 153.ecw:Calculations Jth = 3.500in x Depth = 11.875in, Ends are Pin-Pin 0.151 : 1 2.6 k-ft Maximum Shear * 1.E 17.2 k-ft Allowable 2.60 k-ft at 4.000 ft Shear: 0.00 k-ft at 0.000 ft 0.00 k-ft Camber: 0.00 k-ft Max. M allow 17.24 Reactions... fb 379.41 psi fv 35.67 psi Left DL Fb 2,515.19 psi Fv 285.00 psi Right DL Deflections i 1.5 k 11.8 k @ Left 1.30 k @ Right 1.30 k @ Left 0.000in @ Center 0.022in @ Right 0.000in 0.58 k Max 1.30 k 0.58 k Max 1.30 k Center Span... Dead Load Total Load Left Cantilever... Lead Load I otal Load Deflection -0.014 in -0.032 in Deflection 0.000 in 0.000 in ...Location 4.000 ft 4.000 ft ...Length/Deft 0.0 0.0 ...Length/Deft 6,662.1 2,973.46 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.022 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 15.922 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 13.612 Cl 0.967 Max Moment Sxx Reg'd Allowable fb @ Center 2.60 k-ft 12.41 in3 2,515.19 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 1.48 k 1.48 k Area Required 5.202 in2 5.202 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.30 k Bearing Length Req'd 0.495 in Max. Right Reaction 1.30 k Bearing Length Req'd 0.495 in Title : 24F - V8 Doug[ Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Description Bm #9 General Timber Beam Page 2 5b 153.ecw:Calculations Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.30 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : 983-2003 Description Bm #10 Ver5.8.0, 1-Dec-2003 CALC Engineering Software Steel Beam Design Page 1 5b 153.emCalculations General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W1OX45 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 20.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 14.50 ft Point Loads Note! Short Term Loads Are WIND Loads. 1111 #1 #2 #3 #4 #5 #6 #7 Dead Load 8.400 k Live Load 7.200 k Short Term k Location 14.500 ft Summary Using: W 10X45 section, Span = 20.00ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 14.50ft, LDF = 1.000 Actual Allowable Moment 63.925 k-ft 122.750 k-ft fb : Bending Stress 15.623 ksi 30.000 ksi fb / Fb 0.521 : 1 Shear 11.762 k 70.700 k fv : Shear Stress 3.327 ksi 20.000 ksi fv / Fv 0.166 :1 Beam OK Static Load Case Governs Stress Max. Deflection -0.492 in Length/DL Defl 871.3 :1 Length/(DL+LL Defl) 487.4 :1 Force & Stress Summary _ , These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 63.92 k-ft 35.25 63.92 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 4.74 k 2.76 4.74 k Shear @ Right 11.76 k 6.54 11.76 k Center Defl. -0.492 in -0.275 -0.492 -0.492 0.000 0.000 in Left Cant Dell 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 4.74 2.76 4.74 4.74 k Reaction @ Rt 11.76 6.54 11.76 11.76 k Fa calc'd per Eq. E2-2, K*L/r > Cc I Beam, Major Axis, (102,000 * Cb / Fy)A. 5 L/rT (510,000 * Cb / Fy)A.5 , Fb per Eq. F1-6 1 Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / (I * d) Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580006 Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983-2003 ENERCALC Engineering Software _ 5b 153.ecw:Calculations Description Bm #10 Section Properties W1OX45 Depth 10.100 in Weight 45.18 #/ft Web Thick 0.350 in Ixx 248.000 in4 Width 8.020 in lyy 53.400 in4 Flange Thick 0.620 in Sxx 49.100 in3 Area 13.30 in2 Syy 13.300 in3 Rt 2.180 in R-xx 4.320 in Value's for LRFD Design.... R-yy 2.010 in J 1.510 in4 Zx 54.900 in3 CW 1,200.00 in6 Zy 20.300 in3 K 1.120 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Hew 580006 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983.2003 ENERCALC Engineerino Software Description Bm #11 Page 1 5b 153.ecw:Calculations General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X54 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 20.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 14.50 ft Point Loads Note! Short Term Loads Are WIND Loads. - -_.r 7 - ft, #1^ #2 #3 #4 #5 #6 #7 Dead Load 9.300 k Live Load 9.100 k Short Term k Location 14.500 ft Summary Beam OK Static Load Case Governs Stress Using: W1 OX54 section, Span = 20.00ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 14.50ft, LDF = 1.000 Actual Allowable Moment 75.414 k-ft 150.000 k-ft Max. Deflection -0.476 in fb : Bending Stress 15.083 ksi 30.000 ksi Length/DL DO 955.9 :1 fb / Fb 0.503 : 1 Length/(DL+LL Defl) 504.7: 1 Shear 13.877 k 74.666 k fv : Shear Stress 3.717 ksi 20.000 ksi fv / Fv 0.186 : 1 Force & Stress Summary « - These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 75.41 k-ft 39.18 75.41 k-ft Max. M - Max. M @ Left Max. M @ Right Shear @ Left 5.60 k Shear @ Right 13.88 k Center Defl. -0.476 in Left Cant DO 0.000in Right Cant DO 0.000 in ...Query Defl @ 0.000 ft 3.09 5.60 7.28 13.88 -0.251 -0.476 -0.476 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 k-ft k-ft k-ft k k 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in Reaction @ Left 5.60 3.09 5.60 5.60 k Reaction @ Rt 13.88 7.28 13.88 13.88 k Fa calc'd per Eq. E2-2, K*L/r > Cc I Beam, Major Axis, (102,000 * Cb / Fy)^.5 UrT (510,000 * Cb / Fy)11.5 , Fb per Eq. F1-6 1 Beam, Major Axis, Fb per Eq. F1-8, Fb =12,000 Cb Af / (I * d) Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : HOW Ibbu(M) User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Soft Description Bm #11 Steel Beam Design Page 2 5b 153.ecw:Calculations Section Properties W1OX54 Depth 10.090 in Weight 53.67 #/ft Web Thick 0.370 in Ixx 303.000 in4 Width 10.030 in lyy 103.000 in4 Flange Thick 0.615 in Sxx 60.000 in3 Area 15.80 in2 Syy 20.600 in3 Rt 2.750 in R-xx 4.370 in Values for LRFD Design... . R-yy 2.560 in J 1.820 in4 Zx 66.600 in3 Cw 2,320.00 in6 Zy 31.300 in3 K 1.120 in Title : 24F - V8 Dsgnr: Description Scope : Dougl Job # Date: 6:58AM, 16 JAN 06 -Rev: 590006 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983-2003 ENERCALC Engineering Software _ Sb 153.ecw:Calculations Description Bm #12 eneral Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 1111 G Steel Section : W10X112 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 20.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 14.50 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 44 #5 #6 #7 Dead Load 20.200 k Live Load 40.400 k Short Term k Location 14.500 ft Using: W 10X112 section, Span= 20.00ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 14.50ft, LDF = 1.000 Actual Allowable Moment 245.775 k-ft 315.000 k-ft fb : Bending Stress 23.407 ksi 30.000 ksi fb / Fb • 0.780 : 1 Shear 45.053 k 171.536 k fv : Shear Stress 5.253 ksi 20.000 ksi fv / Fv 0.263 :1 Beam OK Static Load Case Governs Stress Max. Deflection -0.652 in Length/DL Defl 1,043.7: 1 Length/(DL+LL Defl) 368.3: 1 Force & Stress Summary « These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 245.78 k-ft 84.90 245.78 k-ft Max. M - Max. M @ Left Max. M @ Right Shear @ Left 17.78 k Shear @ Right 45.05 k Center Defl. -0.652 in Left Cant Defl 0.000in Right Cant Defl 0.000 in ...Query Defl @ 0.000 ft 6.67 17.78 15.76 45.05 -0.230 -0.652 -0.652 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 k-ft k-ft k-ft k k 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in Reaction @ Left 17.78 6.67 17.78 17.78 k Reaction @ Rt 45.05 15.76 45.05 45.05 k Fa calc'd per Eq. E2-2, K*Ur > Cc I Beam, Major Axis, (102,000 * Cb / Fy)A.5 UrT (510,000 * Cb / Fy)A.5, Fb per Eq. F1-6 1 Beam, Major Axis, Fb per Eq. F1-8, Fb =12,000 Cb Af / (I * d) Title : 24F-V8 Dsgnr: Description Scope : Dougl Job # Date: 6:58AM, 16 JAN 06 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design Page 2 (c)1983.2003 ENERCALC Engineering Software 51c 153.ecw:Calculations Description Bm #12 Section Properties W10X112 Depth 11.360 in Weight 111.75 #/ft Web Thick 0.755 in Ixx 716.000 in4 Width 10.415 in lyy 236.000 in4 Flange Thick 1.250 in Sxx 126.000 in3 Area 32.90 in2 Syy 45.300 in3 Rt 2.880 in R-xx 4.660 in Values for LRFD Design R-yy 2.680 in J 15.100 in4 Zx 147.000 in3 Cw 6,030.00 in6 Zy 69.200 in3 K 1.750 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : 1 Steel Beam Design Page 1 Description Bm #13 General Information Steel Section : W10X88 Center Span 20.00 ft Left Cant. 0.00 ft Right Cant 0.00 ft Lu : Unbraced Length 14.50 ft Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Fy 50.00 ksi Pinned-Pinned Load Duration Factor 1.00 Bm Wt. Added to Loads Elastic Modulus 29,000.Oksi LL & ST Act Together Point Loads #1 #2 #3 Dead Load' 11.400 Live Load 22.200 Short Term Location 14.500 Beam OK Static Load Case Governs Stress Using: W 10X88 section, Span = 20.OOft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 14. 50ft, LDF = 1.000 Actual Allowable Moment 137.311 k-ft 246.250 k-ft Max. Deflection -0.490 in fb : Bending Stress 16.728 ksi 30.000 ksi Length/DL Defl 1,335.3 :1 fb / Fb 0.558 : 1 Length/(DL+LL Defl) 489.4: 1 Shear 25.240 k 131.164 k fv : Shear Stress 3.849 ksi 20.000 ksi fv / Fv 0.192 : 1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 137.31 k-ft 48.91 137.31 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 10.12 k 4.01 10.12 k Shear @ Right 25.24 k 9.14 25.24 k Center Defl. -0.490 in -0.180 -0.490 -0.490 0.000 0.000 in Left Cant DefI 0.000 in 0.000 0.000 0.000 0.000 0.000 in Right Cant DO 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query DO @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 10.12 4.01 10.12 10.12 k Reaction @ Rt 25.24 9.14 25.24 25.24 k Fa calc'd per Eq. E2-2, K'Ur > Cc I Beam, Major Axis, (102,000 ` Cb / Fv)A.5 UrT (510, 000' Cb / F#1.5, Fb per Eq. F1-6 I Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / (I "d) Note! Short Term Loads Are WINU Loads. #4 #5 #6 #7 k k k ft Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580006 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983-2003 ENERCALC Engineerino Software Description Bm #13 Page 2 5b 153.ecw:Calculations Section Properties W1OX88 Depth 10.840 in Weight 0.~y 87.97 #/ft Web Thick 0.605 in Ixx 534.000 in4 Width 10.265 in lyy 179.000 in4 Flange Thick 0.990 in Sxx 98.500 in3 Area 25.90 in2 Syy 34.800 in3 Rt 2.830 in R-xx 4.540 in Values for LRFD Design R-yy 2.630 in J 7.530 in4 Zx 113.000 in3 Cw 4,330.00 in6 Zy 53.100 in3 K 1.490 in Title : 24F-V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description Scope : nev: oouuuo User: KW-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Desi n Page 1 (c)1983-2003 ENERCALC Engineering Software g Sb 153.ecw:Calculations Description Bm #14 General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X30 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 20.00 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 14.50 ft Point Loads #1 Dead Load 3.200 Live Load 5.300 Short Term Location 14.500 #L # 0.400 0.800 16.250 #4 #5 Note! Short Term Loads Are WIND Loads. #6 #7 k k k ft Summary Using: W1 OX30 section, Span = 20.00ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 14.50ft, LDF = 1.000 Actual Moment 38.305 k-ft fb : Bending Stress 14.187 ksi fb / Fb 0.727 : 1 Shear 7.438 k fv : Shear Stress 2.368 ksi fv / Fv 0.118 : 1 Beam OK Static Load Case Governs Stress Allowable 52.698 k-ft Max. Deflection -0.434 in 19.518 ksi Length/DL Defl 1,370.7 :1 Length/(DL+LL Defl) 553.5 :1 62.820 k 20.000 ksi Force & Stress Summary « - These columns are Dead + Live Load plac ed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 38.30 k-ft 15.03 38.30 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 2.86 k 1.26 2.86 k Shear @ Right 7.44 k 2.95 7.44 k Center Defl. -0.434 in -0.175 -0.434 -0.434 0.000 0.000 in Left Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query DO @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 2.86 1.26 2.86 2.86 k Reaction @ Rt 7.44 2.95 7.44 7.44 k Fa caldd per Eq. E2-2, K"L/r > Cc I Beam, Major Axis, L/rT > (510,000' Cb / Fy)^.5, Fb per Eq. F1-7 1 Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / (I' d) Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver 5.8.0, 1 (c)1983-2003 ENEACALC Engir Description Bm #14 Steel Beam Design Page 2 5b 153-ecw: Calculations Section Properties W1OX30 Depth 10.470 in Weight 30.03 #/ft Web Thick 0.300 in Ixx 170.000 in4 Width 5.810 in lyy 16.700 in4 Flange Thick 0.510 in Sxx 32.400 in3 Area 8.84 in2 Syy 5.750 in3 Rt 1.550 in R-xx 4.380 in Values for LRFD Design.... R-yy 1.370 in J 0.620 in4 Zx 36.600 in3 Cw 414.00 in6 Zy 8.840 in3 K 0.810 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : Rev: 580006 User: Kw-0606238, Ver5.8.0, 1-Dec-2003 Steel Beam Design (c)1983.2003 ENERCALC Engineering Software Description Bm #15 Page 1 5b 153.ecw:Calculations Summary Beam OK Static Load Case Governs Stress Using: W 10X22 section, Span = 5.50ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 5.50ft, LDF = 1.000 Actual Allowable Moment 19.249 k-ft 58.000 k-ft Max. Deflection -0.023 in fb : Bending Stress 9.956 ksi 30.000 ksi Length/DL Defl 5,762.1 :1 fb / Fb •0.332 : 1 Length/(DL+LL Defl) 2,810.3: 1 Shear 11.551 k 48.816 k fv : Shear Stress 4.732 ksi 20.000 ksi fv / Fv 0.237 : 1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 19.25 k-ft 9.37 19.25 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 11.55 k 5.63 11.55 k Shear @ Right 5.07 k 2.49 5.07 k Center Defl. -0.023 in -0.011 -0.023 -0.023 0.000 0.000 in Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query DO @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 11.55 5.63 11.55 11.55 k Reaction @ Rt 5.07 2.49 5.07 5.07 k Fa calc'd per Eq. E2-1, K*L/r < Cc I Beam, Major Axis, L/rT < (102,000 * Cb / Fy)A.5, Fb = 0.6 Fy (F3) I Beam, Major Axis, Fb per Eq. F1-8, Fb =12,000 Cb Af / (I * d) Title : 24F - V8 Dsgnr: Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software gom Description Elm #15 Steel Beam Design Dougl Job # Date: 6:58AM, 16 JAN 06 Page 2 5b 153.ecw:Calculation s Section Properties W1OX22 Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in lxx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in Values for LRFD Design.... R-yy 1.330 in J 0.240 in4 Zx 26.000 in3 CW 275.00 in6 Zy 6.100 in3 K 0.660 in Title : 24F - V8 Dsgnr: Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Rom Description Bm #16 General Information General Timber Beam Dougl Job # Date: 6:58AM, 16 JAN 06 Page 1 5b 153.ecw:Calculations Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Beam Width 3.500 in Beam Depth 11.875 in Member Type Manuf/So.Pine Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000pcf Full Length Uniform Loads Center DL Left Cantilever DL Right Cantilever DL Center Span 8.00 ft .....Lu Left Cantilever ft .....Lu Right Cantilever ft .....Lu Truss Joist - MacMillan, MicroLam 1.9 E Fb Base Allow 2,600.0 psi Fv Allow 285.0 psi Fc Allow 750.0 psi E 1,900.0 ksi 60.00 #/ft LL 80.00 #/ft #/ft LL #/ft #/ft LL #/ft Span= 8.00ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.070 : 1 Maximum Moment 1.2 k-ft Maximum Shear * 1. Allowable 17.2 k-ft Allowable Max. Positive Moment 1.20 k-ft at 4.000 ft Shear: Max. Negative Moment 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k-ft Camber: Max @ Right Support 0.00 k-ft Max. M allow 17.24 Reactions... fb 175.18 psi fv 16.47 psi Left DL 0.28 k , Fb 2,515.19 psi Fv 285.00 psi Right DL 0.28 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dt Deflection -0.007 in -0.015 in Deflection ...Location 4.000 ft 4.000 ft ...Length/Deft ...Length/Defl 13,789.6 6,440.13 Right Cantilever... Camber ( using 1.5 * D.L . Defl ) Deflection @ Center 0.010 in ...Length/Defl @ Left @ Right 0.000 in 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 15.922 ft Sxx 82.259 in3 Cf 1.000 Rb 13.612 CI 0.967 Max Moment Sxx Read @ Center 1.20 k-ft 5.73 in3 @ Left Support 0.00 k-ft 0.00 in3 @ Right Support 0.00 k-ft 0.00 in3 Shear Analysis @ Left Support @ Right Support Design Shear 0.68 k 0.68 k Area Required 2.402 in2 2.402 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction Max. Right Reaction 0.60 k Req'd 0.60 k Bearing Length Bearing Length Req'd 8.00 ft 0.00 ft 0.00 ft Beam Design OK 0.7 k 11.8 k @ Left 0.60 k @ Right 0.60 k @ Left 0.000 in @ Center 0.010in @ Right 0.000in Max 0.60 k Max 5 0.60 k 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 Area 41.563 in2 Allowable fb 2,515.19 psi 2,600.00 psi 2,600.00 psi 0.229 in 0.229 in Title : 24F-V8 Dsgnr: Description Scope : Dougl Job # Date: 6:58AM, 16 JAN 06 Rev: 580004 - Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software Sb 153.ecw:Calculations Description Bm #16 Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = Moment Shear Deflection 0.00 ft 0.00 k-ft 0.60 k 0.0000 in 0.00 ft 0.00 k-ft 0.00 k 0.0000 in 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : 24F - V8 Dougl Job # Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #17 Steel Beam Design General Information Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Steel Section : W10X88 Fy 50.00ksi Pinned-Pinned Load Duration Factor 1.00 Center Span 13.75 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 It Lu : Unbraced Length 7.00 ft Distributed Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 DL 0.850 0.300 k/ft LL 0.110 0.400 k/ft ST k/ft Start Location 1.500 ft End Location 1.500 13.750 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 #6 #7 Dead Load 0.600 15.800 k Live Load 0.700 29.300 k Short Term k Location 1.500 6.830 ft ~unuuat y Beam OK Static Load Case Governs Stress Using: W 10X88 section, Span = 13.75ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 7.00ft, LDF = 1.000 Actual Allowable Moment 174.549 k-ft 270.875 k-ft Max. Deflection -0 316 in fb : Bending Stress 21.265 ksi 33.000 ksi . fb / Fb 0.644 : 1 Length/DL Defl 1,403.1 : 1 Length/(DL+LL Defl) 521.6 :1 Shear 29.642 k 131.164 k fv : Shear Stress 4.520 ksi 20.000 ksi fv / Fv 0.226 : 1 Force & Stress Summary These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 174.55 k-ft 64.16 174.55 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 29.64 k 11.93 29.64 k Shear @ Right 27.98 k 10.63 27.98 k Center Defl. -0.316 in -0.118 -0.316 -0.316 0.000 0.000 in Left Cant DO 0.000 in 0.000 0.000 0.000 0.000 0.000 in Right Cant DO 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0.000 0.000 0.000 0.000 in Reaction @ Left 29.64 11.93 29.64 29.64 k Reaction @ Rt 27.98 10.63 27.98 27.98 k Fa calc'd per Eq. E2-1, K'Ur < Cc I Beam Passes Table B5.1, Fb per Eq. F1-1, Fb = 0.66 Fy Page 1 5b 153.ecw:Calculations Title : 24F - V8 Dougl Job Dsgnr: Date: 6:58AM, 16 JAN 06 Description : Scope : USerKW' 08238,Ver5-8.0,1-Dec-2003 Steel Beam Design (c)1983.2003 ENERCALC Engineering Software Description Bm #17 Page 2 5b 153.emCalculations Section Properties W10X88 Depth 10.840 in _r Weight 87.97 #/ft Web Thick 0.605 in Ixx 534.000 in4 Width 10.265 in lyy 179.000 in4 Flange Thick 0.990 in Sxx 98.500 in3 Area 25.90 in2 Syy 34.800 in3 At 2.830 in R-xx 4.540 in Values for LRFD Design.... R-yy 2.630 in J 7.530 in4 Zx 113.000 in3 Cw 4,330.00 in6 Zy 53.100 in3 K 1.490 in Monroe & Newell Engineers, Inc. PRODUCT 2044 (Single Sheets) 2051 (Padded) JOB SHEET NO. OF_ CALCULATED BY DATE CHECKED BY DATE SCALE L ~ N QO Lf) uI e - 1 1- I I S u [-,I Iw L R r , JOB \h-- Df:a Monroe & Newell Engineers, Inc. SHEET No. OF A LATED BY~ DATE sl'. CALCU CHECKED BY DATE SCALE Ft r t 4 1 A / ~ -70 f L 2r~i~ L( JOB VIE D9- el.~ 5 & Lf d=~_ -1 ' oaf ' Monroe & Newell Engineers, Inc. SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE SCALE PRODUCT 204-11Single Sheets) 2054 (Padded) JOB Monroe & Newell 3 Engineers, Inc. SHEET NO. OF A CALCULATED BY DATE CHECKED BY DATE SCALE i, 2- 20, PRODUCT 204-1 (Single Sheets) 205-1(Padded) 515 ~I PIC_ Title : Job # y @ Dsgnr: Off? Date: 1:59PM, 15 JAN 06 Description : SI G Scope : *D 5;pa''92 Rev: 580004 Page 1 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 General Timber Beam (41983.2003 ENERCALC Enaineerina Software 5b 155.ecw:Calculaticns Description Hdr #1 General information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name 3-2x10 Center Span 3.25 ft .....Lu 2.00 ft Beam Width 4.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 9.250 in Right Cantilever ft .....Lu 0.00 ft Member Type Sawn Douglas Fir - Larch, No.2 Bm Wt. Added to Loads Fb Base Allow 900.0 psi Load Dur. Factor 1.000 Fv Allow 180.0 psi Beam End Fixity Pin-Pin Fc Allow 625.0 psi Wood Density 35.000 pcf E 1,600.0 ksi Full Length Uniform Loads Center DL 600.00 #/ft LL 560.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Beam Design OK Span= 3.25ft, Beam Width = 4.500in x Depth = 9.25in, Ends are Pin-Pin Max Stress Ratio 0.381 : 1 Maximum Moment 1.5 k-ft Maximum Shear * 1. Allowable 5.8 k-ft Allowable Max. Positive Moment 1.54 k-ft at 1.625 ft Shear: Max. Negative Moment 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k-ft Camber: Max @ Right Support 0.00 k-ft Max. M allow 5.77 Reactions... fb 288.90 psi fv 68.52 psi Left DL Fb 1,078.06 psi Fv 180.00 psi Right DL Deflections 2.9 k 7.5 k @ Left 1.90 k @ Right 1.90 k @ Left 0.000 in @ Center 0.005 in @ Right 5 0.000in 0.99 k Max 1.90 k 0.99 k Max 1.90 k Center Span... Dead Load Total Load Lett cantilever... ueaa Loaa I oral Loaa Deflection -0.003 in -0.006 in Deflection 0.000 in 0.000 in ...Location 1.625 ft 1.625 ft ...Length/Deft 0.0 0.0 ...Length/Deft 12,092.7 6,305.32 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.005 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 34.195 Le 4.118 ft Sxx 64.172 in3 Area 41.625 in2 Cf 1.200 Rb 4.752 Cl 0.998 Max Moment Sxx Read Allowable fb @ Center 1.54 k-ft 17.20 in3 1,078.06 psi @ Left Support 0.00 k-ft 0.00 in3 1,080.00 psi @ Right Support 0.00 k-ft 0.00 in3 1,080.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 2.85 k 2.85 k Area Required 15.845 in2 15.845 in2 Fv: Allowable 180.00 psi 180.00 psi Bearing @ Supports Max. Left Reaction 1.90 k Bearing Length Req'd 0.676 in Max. Right Reaction 1.90 k Bearing Length Req'd 0.676 in 64s ' Title : Dsgnr: Of Y? Description Scope : Job # 9-;@ Date: 1:59PM, 15 JAN 06 's )S5, Y F 42 - FieV: bbuvU4 Page User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software 5b 155.ecw:Calculaticns Description Hdr #1 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.90 k 0.0000 in • Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: 00 Description Scope : Job # Y_@ Date: 1:59PM, 15 JAN 06 SIBS) EJ ~T= D(2, Rev: 580004 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software 5b 155.ecw:Calculations Description Hdr #2 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x9.5 Center Span 6.50 ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 9.500 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Full Length Uniform Loads Center DL 700.00 #/ft LL 775.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Summary Span= 6.50ft, Beam Width = 3.500in x Depth = 9.5in, Ends are Pin-Pin Max Stress Ratio 0.763 : 1 Maximum Moment 7.8 k-ft Maximum Shear * 1.5 Allowable 11.4 k-ft Allowable Max. Positive Moment 7.83 k-ft at 3.250 ft Shear: @ Left Max. Negative Moment 0.00 k-ft at 6.500 ft @ Right Max @ Left Support 0.00 k-ft Camber: @ Left Max @ Right Support 0.00 k-ft @ Center Max. M allow 11.35 Reactions... @ Right fb 1,785.33 psi fv 217.44 psi Left DL 2.30 k Max Fb 2,587.86 psi Fv 285.00 psi Right DL 2.30 k Max Beam Design OK 7.2 k 9.5 k 4.82 k 4.82 k 0.000 in 0.090 in 0.000 in 4.82 k 4.82 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.060 in -0.125 in Deflection 0.000 in 0.000 in ...Location 3.250 ft 3.250 ft ...Length/Deft 0.0 0.0 ...Length/Deft 1,303.2 622.18 Right Cantilever... Camber ( using 1.5 ' D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.090 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 52.646 in3 Area 33.250 in2 Cf 1.000 Rb 6.192 CI 0.995 Max Moment Sxx Reo'd Allowable fb @ Center 7.83 k-ft 36.32 in3 2,587.86 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 7.23 k 7.23 k Area Required 25.368 in2 25.368 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 4.82 k Bearing Length Req'd 1.836 in Max. Right Reaction 4.82 k Bearing Length Req'd 1.836 in Title : Job # 9- @ Dsgnr: Oli? Date: 1:59PM, 15 JAN 06 Description : S155;513 Scope : IF C)n Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 2 (c)1983.2003 ENERCALC Engineering Software 5b 155.ecw:Calculations Description Hdr #2 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 4.82 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: Of'i? Description Scope : Job # y-@ Date: 1:59PM, 15 JAN 06 I nev. JaUUU/ User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 1 (c)1983.2003 ENERCALC Engineering Software 5b 155.ecw:Calculations Description Bm #1 General information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Center Span 11.25 ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 It Beam Depth 11.875 in Right Cantilever It .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Trapezoidal Loads #1 DL @ Left 60.00 #/ft LL @ Left 120.00 #/ft Start Loc 0.000 ft DL @ Right 60.00 #/ft LL @ Right 120.00 #/ft End Loc 5.170 ft #2 DL @ Left 85.00 #/ft LL @ Left 155.00 #/ft Start Loc 5.170 ft DL @ Right 85.00 #/ft LL @ Right 155.00 #/ft End Loc 11.250 ft Beam Design OK Span= 11.25ft, Beam V~ Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support 'idth = 3.500in x Depth = 11.875in, Ends are Pin-Pin 0.201 : 1 3.6 k-ft Maximum Shear * 1.E 17.7 k-ft Allowable 3.57 k-ft at 5.895 ft Shear: -0.00 k-ft at 11.250 ft 0.00 k-ft Camber: 0.00 k-ft Max. M allow 17.72 Reactions... fb 520.19 psi fv 48.20 psi Left DL Fb 2,584.51 psi Fv 285.00 psi Right DL Deflections 2.0 k 11.8 k @ Left 1.17k @ Right 1.34 k @ Left 0.000 in @ Center 0.049in @ Right 0.000in 0.44 k Max 1.17k: 0.51 k Max 1.34 k Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.033 in -0.087 in Deflection 0.000 in 0.000 in ...Location 5.715 ft 5.670 ft ...Length/Deft 0.0 0.0 ...Length/Deft 4,127.0 1,551.83 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.049 in ...Length/Dell 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Oalcs Bending Analysis Ck 21.924 Le 4.118 It Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 6.923 Cl 0.994 Max Moment Sxx Read Allowable fb @ Center 3.57 k-ft 16.56 in3 2,584.51 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 1.75 k 2.00 k Area Required 6.147 in2 7.029 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.17 k Bearing Length Req'd 0.445 in Max. Right Reaction 1.34 k Bearing Length Req'd 0.509 in Title : Dsgnr: Oli? Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #1 General Timber Beam Job # y~ @ Date: 1:59PM, 15 JAN 06 SIC-6) Page 2 5b 155.ecw:Calculations Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.17 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: 01'i? Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #2 General Timber Beam Job # y-@ Date: 1:59PM, 15 JAN 06 ~Sksr5 1 SJ3 '14F Pik-. Page 1 5b 155.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 13.50 ft .....Lu 2.00 ft 00 ft 0 Beam Width 5.250 in . Left Cantilever ft .....Lu Beam Depth 11.875 in Right Cantilever ft ....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi #1 DL @ Left 115.00 #/ft LL @ Left 150.00 #/ft Start Loc 5.670 ft DL @ Right 115.00 #/ft LL @ Right 150.00 #/ft End Loc 13.500 ft Point Loads Live Load 800.0 Ibs ...distance 5.670 ft Ibs Ibs Ibs Ibs 0.000 ft 0.000 ft Ibs Ibs IDS iu5 Ibs Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft 0.000 ft Beam Design OK Span= 13.50ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.301 ; 1 Maximum Moment 8.0 k-ft Maximum Shear * 1.5 3.2 k Allowable 26.7 k-ft Allowable 17.8 k Max. Positive Moment 8.03 k-ft at 5.940 ft Shear: @ Left @ Right 1.46 k 12 k 2 Max. Negative Moment 0.00 k-ft at 0.000 ft . Max @ Left Support 0.00 k-ft Camber: @ Left 0.000 in Max @ Right Support 0.00 k-ft @ Center 0.116 in @ Right O.000in Max. M allow 26.67 Reactions... fb 781.20 psi fv 51.04 psi Left DL 0.65 k Mai 1.46 k Fb 2,593.50 psi Fv 285.00 psi Right DL 0.95 k Max 2.12 k Deflections Center Span... Dead Load Total Load Left Cantilever... uead Load Total Load Deflection -0.077 in -0.177 in Deflection 0.000 in 0.000 in ...Location 6.804 ft 6.804 ft ...Length/Deft 0.0 0.0 ...Length/Deft 2,090.9 915.36 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.116 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 4.615 Cl 0.997 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Max Moment Sxx Reo'd Allowable fb 8.03 k-ft 37.17 in3 2,593.50 psi 0.00 k-ft 0.00 in3 2,600.00 psi 0.00 k-ft 0.00 in3 2,600.00 psi @ Left Support @ Right Support 2.19 k 3.18 k 7.674 in2 11.166 in2 285.00 psi 285.00 psi 1.46 k Bearing Length Req'd 0.370 in 2.12 k Bearing Length Req'd 0.539 in Title : Dsgnr: 01'i? Description Scope : Job # 9.7@ Date: 1:59PM, 15 JAN 06 56 56 I= Olz er KW-0606238, Ver 5.8.0, 1-Dec-2003 1983.2003 ENERCALC Engineering Software Description Bm #2 General Timber Beam Page 2 5b 155.ecw:Calculations Query Values M, V, & D @ Specified Locations Moment Shear @ Center Span Location = 0.00 ft 0.00 k-ft 1.46 k @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in Title : Job # 9-_ @ Dsgnr: 6f? Date: 1:59PM, 15 JAN 06 Description : S1545i E5g Scope : VF 1-Dec-2003 ineering Software Description Bm #3 General Timber Beam Page 1 5b 155.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 13.50 ft .....Lu 2.00 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Trapezoidal Loads #1 DL @ Left 115.00 #/ft LL @ Left 150.00 #/ft Start Loc 5.670 ft DL @ Right 115.00 #/ft LL @ Right 150.00 #/ft End Loc 13.500 ft Point Loads Live Load 800.0 Ibs Ibs Ibs ...distance 5.670 ft 0.000 ft 0.000 ft Ibs Ibs 0.000 ft Ibs Ibs Ibs Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft ummary I Beam Design OK Span= 13.50ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.301 : 1 Maximum Moment 8.0 k-ft Maximum Shear * 1.5 3.2 k Allowable 26.7 k-ft Allowable 17.8 k Max. Positive Moment 8.03 k-ft at 5.940 ft Shear: @ Left 1.46 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 2.12 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.116 in Max. M allow 26.67 Reactions... @ Right 0.000in fb 781.20 psi fv 51.04 psi Left DL 0.65 k Max 1.46 k Fb 2,593.50 psi Fv 285.00 psi Right DL 0.95 k Max 2.12 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.077 in -0.177 in Deflection 0.000 in 0.000 in ...Location 6.804 ft 6.804 ft ...Length/Deft 0.0 0.0 ...Length/Deft 2,090.9 915.36 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.116 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 4.615 Cl 0.997 Max Moment Sxx Reo'd Allowable fb @ Center 8.03 k-ft 37.17 in3 2,593.50 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 2.19 k 3.18 k Area Required 7.674 in2 11.166 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.46 k Bearing Length Req'd 0.370 in Max. Right Reaction 2.12 k Bearing Length Req'd 0.539 in Title : Job # y-@ Dsgnr: 01'i? Date: 1:59PM, 15 JAN 06 Description Scope V f`- Rev: 58000a User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam fc11983.2003 ENERCALC Encineerinq Software Page 2 5b 155.ecw.Calculations Description Bm #3 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.46 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Job # y @ Dsgnr: 00 Date: 1:59PM, 15 JAN 06 Description : 6)56,58 Scope : VFDP Description Bm #4 Multi-Span Timber Beam Page 1 5b 155.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Douglas Fir, 24F - V8 Fb : Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Spans Considered Continuous Over Support Fv : Basic Allow 240.0 psi Load Duration Factor 1.000 Timber Member Information Description Span ft 9.00 5.75 4.00 Timber Section 6.75x15 6.75x15. 6.75x15 Beam Width inl 6.750 6.750 6.750 Beam Depth in 15.000 15.000 15.000 End Fixity Pin - Pin Pin - Pin Pin - Free Le: Unbraced Length ftl 9.00 5.75. 4.00 Member Type GluLam GluLam GluLam Loads Live Load Used This Span ? Yes Yes Yes Dead Load Wit 205.00 430.00 430.00 Live Load #/ft 270.00 865.00 865.00 Results Mmax @ Cntr in-k1 41.1 0.0 0.0 = @ X ft ' I 3.78 0.00 4.00 Max @ Left End in-k 0.0 -36.0 -124.3 Max @ Right End in-k -36.0 -124.3 0.0 fb : Actual psi 162.4 491.1 491.1 Fb : Allowable psi 2,376.3 2,385.6 2,390.3 i Bending OK Bending OK Bending OK Shear @ Left k, 1.80 2.44 5.18 Shear @ Right k 2.47 5.00 0.00 fv : Actual psi 27.7 49.8 53.2 Fv : Allowable psi 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k 0.78 1.93 3.33 LL @ Left k 1.02 2.99 6.85 Total @ Left k 1.80 4.91 10.18 DL @ Right k 1.93 3.33 0.00 LL @ Right k 2.99 6.85 0.00 Total @ Right k ! 4.91 10.18 0.00 Max. Deflection in I -0.014 0.005 -0.049 @ X = ft l 4.14 3.76 ^ T 4.00 Query Values 00V U. KW-0606238, Ver 5.8.0, 1-Dec-2003 2-2003 ENERCALC Engineering Software Location fti 0.00 Moment in-k. 0.0 Shear k 1.8 Deflection in, 0.0000 -36.0 2.4 0.0000 0.00 -124.3 5.2 0.0000 Title : Job # 9 @ Dsgnr: Off? Date: 1:59PM, 15 JAN 06 Description : 55 Scope Rev: 580004 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi-Span Timber Beam (c)1983-2003 ENERCALC Engineering Software 5b 155.ecw:Calculations Description Bm #5 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Douglas Fir, 24F - V8 Fb : Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Spans Considered Continuous Over Support Fv : Basic Allow 240.0 psi Load Duration Factor 1.000 Timber Member Information Description Span ft 5.75 3.25 Timber Section 6.75x15. 6.75x15 Beam Width inl 6.750 6.750 Beam Depth in 15.000 15.000 End Fixity Pin - Pin Pin - Pin Le: Unbraced Length ft 5.75 3.25 Member Type Glul-am GluLam m _Am 1.00 6.75x15 6.750 15.000 Pin - Free 1.00 GluLam Loads Live Load Used This Span ? Yes Yes Yes Dead Load #/ft 705.00 390.00 390.00 Live Load #/ft; 965.00 775.00 775.00 Results Mmax @ Cntr in-k 56.2 0.0 0.0 @ X = l ft i 2.38 0.00 1.00 Max @ Left End in-k' 0.0 -58.3 -7.0 Max @ Right End in-k, -58.3 -7.0 0.0 fb : Actual psi 230.4 230.4 27.6 Fb : Allowable psi 2,385.6 2,392.2 2,397.7 Bending OK Bending OK Bending OK Shear @ Left k 3.96 3.21 1.16 Shear @ Right k 5.65 0.58 0.00 fv : Actual psi 52.4 26.2 0.0 Fv : Allowable psi 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k 1.68 3.57 0.46 LL @ Left k 2.28 5.29 1.28 Total @ Left kj 3.96 8.86 1.74 DL @ Right ki 1 3.57 0.46 0.00 LL @ Right k 5.29 1.28 0.00 Total @ Right kl 8.86 1.74 0.00 Max. Deflection in 0.007 0.001 -0.001 @ X = ft 2.61 1.23 1.00 Query Values Location ft i 0.00 0.00 0.00 Moment in-k 0.0 -58.3 -7.0 Shear k~ 4.0 3.2 1.2 Deflection in 0.0000 0.0000 0.0000 Monroe & Newell Engineers, Inc. PRODUCT 2041 (Single Sheets) 205-1(Padded) JOB SHEET NO. CALCULATED BY CHECKED BY_ SCALE OF DATE DATE d i 1 •~/I10_.46 S b-,"' .O-.4 x~ I Nr JO Y1 Z J I- r M :r `31 ~ ~ J CLXOIM J 4CS I I ~W o 1 III ~s,o~. I I a c~ ! r I A - - ! - Il ;lid o - 1I g_ I 1° I I I- a II I f LaLG ~ v., .eia. II-r I I ~ - I ;4 OJ y.j.~ A I I INN p=< 4 0 41 - - --~~i Ii "I IAI.A \7 II I III I'~ it 6~ mY :r j II li, I i O r 0 ~ N i ( I t I i I Z i__ I 7 r r '7 I ! I t~~ _ _ I ! I I I _ I ~I I A~i I ~ ~e ~M NIr I I I • LT-4 r a o, I i, t !I:~ li ~ ~ i r } .I, .I A ~ ~ N t ~ ~ ~ I I JOB 1.. r Monroe & Newell I~-7 Engineers, Inc. SHEET NO. .Ll ,j p^ s-r'1 ALCULATEDBY ( NECKED BY SCALE L i T :E ` 5 W~ 1Z~1 l a25 ~ _ _ : R. ( s ~ d, e~ P 113 / Lt7l a ' t 1 1 n p I L 1 ' OF S DATE o DATE PROOUCT 204-1 (Single Sheets) 205-1 (Padded) Monroe & Newell Engineers, Inc. J JOB + t3~°f v ✓ SHEET NO. OF _ ~v DATE CALCULATED BY l CHECKED BY DATE ~i 4 y b - JOB \ ( V Fad fj'~ Monroe & Newell t SHEET NO. OF Engineers, Inc. { CALCULATED BY DATE CHECKED BY DATE SCALE 77 P-1 2- e- tyo ~ " 1 G 42.0 ~ 1 . { . f 51 1, .c t L L..- _ rte- w i ~ ~ ? 1CB I Cl Sid';d Monroe & Newell Engineers, Inc. SHEET No. OF CALCULATED BY DATE 1 CHECKED BY DATE SCALE r 4~ ~Dfz- JOB Monroe e & Newell \ Engineers, Inc. SHEET NO. OF CALCULATED BY DATE a CHECKED BY DATE SCALE Title : Job # @ Dsgnr: fEnf? Date: 12:40PM, 15 JAN 06 Description Scope: Rev: 580006 Page 1 User: KW-0606238, ver5-8.0, 1-Dec-2003 Steel Beam Design 5b upper floor s157.ecw:Calculations (c)1983-2003 ENERCALC Engineering Software Description Hdr #1 Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 General Information r - Fy 50.00 ksi Steel Section : W10X30 Pinned-P inned Load Duration Factor 1.00 Center Span 3.25 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 3.25 ft Note! Short Term Loads Are WIND Loads. Distributed Loads 4 #1 #2 #3 #4 #5 #6 #7 k/ft . DL 0.420 k/ft LL 0.560 k/ft ST ft Start Location ft End Location Note! Short Term Loads Are WIND Loads. Point Loads #1 #2 #3 #4 #5 #6 #7 k Dead Load 12.500 k Live Load 38.000 k Short Term ft Location 3.000 x Beam OK Summary Static Load Case Governs Stress Using: W 10X30 section, Span = 3. 25ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 3.25ft, LDF = 1.000 Actual Allowable Moment 12.008 k-ft 89.100 k-ft Max. Deflection -0.003 in fb : Bending Stress 4.447 ksi 33.000 ksi Length/DL Defl 40,624.5 : 1 fb / Fb 0.135 : 1 Length/(DL+LL pefl) 11,225.8 :1 Shear 48.257 k 62.820 k fv : Shear Stress 15.363 ksi 20.000 ksi fv / Fv 0.768 : 1 Force & Stress Su DL Maximum Only Max. M + 12.01 k-ft 3.05 Max. M - Max. M @ Left Max. M @ Right Shear @ Left 5.53 k 1.69 Shear @ Right 48.26 k 12.27 Center Defl. -0.003 in -0.001 Left Cant DO 0.000in 0.000 Right Cant Defl 0.000 in 0.000 ...Query Defl @ 0.000 ft 0.000 Reaction @ Left 5.53 1.69 Reaction @ Rt 48.26 12.27 Fa calc'd per Eq. E2-1, K'L/r < Cc I Beam Passes Table B5.1, Fb per Eq. F 1-1, Fb = 0.66 Fy These columns are Dead + Live Load placed as noted » < LL LL+ST LL LL+ST @ Center @ Center @ Cants @ Cants 12.01 k-ft k-ft k-ft k-ft 5.53 k 48.26 k -0.003 -0.003 0.000 0.000 in 0.000 0.000 0.000 0.000 in 0.000 0.000 0.000 0.000 in 0.000 0.000 0.000 0.000 in 5.53 5.53 k 48.26 48.26 k Title : Dsgnr: /Eni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Hdr #1 Steel Beam Design Job # Date: 12:40PM, 15 JAN 06 Page 2 5b upper floor s157.ecw:Calculations Section Properties Depth Web Thick Width Flange Thick Area Rt Values for LRFD Design.... J Cw W1 OX30 10.470 in 0.300 in 5.810 in 0.510 in 8.84 in2 1.550 in 0.620 in4 414.00 in6 ;M Weight 30.03 #/ft Ixx 170.000 in4 lyy 16.700 in4 Sxx 32.400 in3 Syy 5.750 in3 R-xx 4.380 in R-yy 1.370 in Zx 36.600 in3 Zy 8.840 in3 K 0.810 in Title : Dsgnr: fErn? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Hdr #2 General Timber Beam Job# -!C:@ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor s157.ecw:Calculations General information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 6.50 ft .....Lu 2.00 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0 ksi Trapezoidal Loads #1 DL @ Left 235.00 #/ft LL @ Left 185.00 #/ft Start Loc 0.000 ft DL @ Right 235.00 #/ft LL @ Right 185.00 #/ft End Loc 1.750 ft #2 DL'@ Left 265.00 #/ft LL @ Left 290.00 #/ft Start Loc 1.750 ft DL @ Right 265.00 #/ft LL @ Right 290.00 #/ft End Loc 6.500 ft Point Loads Dead Load 2,300.0 Ibs 200.0-16S Ibs Ibs Ibs Ibs Ibs Live Load 6,900.0 Ibs 300.0 Ibs Ibs Ibs Ibs Ibs Ibs ...distance 1.750 ft 5.670 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft Summary Beam Design OK Span= 6.50ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.712 : 1 Maximum Moment 14.1 k-ft Maximum Shear * 1.5 12.7 k Allowable 26.7 k-ft Allowable 17.8 k Max. Positive Moment 14.07 k-ft at . 1.768 ft Shear: @ Left 8.44 k Max. Negative Moment -0.00 k-ft at 6.500 ft @ Right 4.73 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.031 in @ Right 0.000in Max. M allow 26.67 Reactions... fb 1,368.18 psi fv 202.96 psi Left DL 2.57 k Max 8.44k Fb 2,593.50 psi Fv 285.00 psi Right DL 1.70 k Max 4.73 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.020 in -0.065 in Deflection 0.000 in 0.000 in ...Location 3.042 ft 2.990 ft ...Length/Deft 0.0 0.0 ...Length/Deft 3,808.4 1,194.77 Right Cantilever... Camber ( using 1.5 ° D.L. DO ) Deflection 0.000 in 0.000 in @ Center 0.031 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Title : Dsgnr: fEni? Description : Scope : Job # E@ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983.2003 ENERCALC Engineering Software 5b upper floor s157.ecw:Calculations Description Hdr #2 Stress Caics Bending Analysis Ck 21.924 Le 4.118 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 4.615 CI 0.997 Max Moment Sxx Req'd Allowable fb @ Center 14.07 k-ft 65.09 in3 2,593.50 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 12.65 k 7.10 k Area Required 44.397 in2 24.917 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 8.44 k Bearing Length Req'd 2.142 in Max. Right Reaction 4.73 k Bearing Length Req'd 1.202 in Query Values mama s M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 8.44 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: fEni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #1 General Timber Beam Job # -_@ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor $157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Center Span 11.25 ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi #1 DL @ Left 60.00 #/ft LL @ Left 120.00 #/ft Start Loc 0.000 ft DL @ Right 60.00 #/ft LL @ Right 120.00 #/ft End Loc 5.170 ft #2 DL @ Left 85.00 #/ft LL @ Left 155.00 #/ft Start Loc 5.170 ft DL @ Right 85.00 #/ft LL @ Right 155.00 #/ft End Loc 1 1.250 ft Summary Beam Design OK Span= 11.25ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0. 201 : 1 Maximum Moment 3.6 k-ft Maximum Shear 1.5 2.0 k Allowable 17.7 k-ft Allowable 11.8 k Positive Moment Max 3.57 k-ft at 5.895 ft Shear: @ Left 1.17 k . Max. Negative Moment -0.00 k-ft at 11.250 ft @ Right 1.34 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.049in @ Right 0.000in Max. M allow 17.72 Reactions... fb 520.19 psi fv 48.20 psi Left DL 0.44 k Max 1.17k Fb 2,584.51 psi Fv 285.00 psi Right DL 0.51 k Max 1.34 k Deflections i Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection 0.033 in 0.087 in Deflection 0.000 in 0.000 in ..Location 5.715 ft 5.670 ft ..Length/Deft 0.0 0.0 ...Length/Dell 4,127.0 1,551.83 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.049 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 6.923 Cl 0.994 Max Moment Sxx Read Allowable fb @ Center 3.57 k-ft 16.56 in3 2,584.51 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 1.75 k 2.00 k Area Required 6.147 in2 7.029 1n2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.17 k Bearing Length Req'd 0.445 in Max. Right Reaction 1.34 k Bearing Length Req'd 0.509 in Title : Dsgnr: A---h'(? Description : Scope : Job # _ - @ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 2 User: KW-0606238, Ver5.8.0, t-Dec-2003 General Timber Beam (c11983-2003 ENERCALC Engineering Software Sb upper floor s157.ecw:Calculations Description Bm #1 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.17 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: fEm? Description : Scope : Job # C-_@ Date: 12:40PM, 15 JAN 06 Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983.2003 ENERCALC Engineering Software Description Bm #2 Page 1 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 13.50 ft .....Lu 8.00 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Trapezoidal Loads #1 DL @ Left 115.00 #/ft LL @ Left 150.00 #/ft Start Loc 5.670 ft DL @ Right 115.00 #/ft LL @ Right 150.00 #/ft End Loc 13.500 ft Point Loads Dead Load 500.0lbs Ibs Ibs Ibs Ibs Ibs Ibs Live Load 800.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 5.670 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000ft Beam Design OK Span= 13.50ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.304 : 1 Maximum Moment 8.0 k-ft Maximum Shear * 1.5 3.2 k Allowable 26.4 k-ft Allowable 17.8 k Max. Positive Moment 8.03 k-ft at 5.940 ft Shear: @ Left 1.46 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 2.12 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.116 in Max. M allow 26.44 Reactions... @ Right 0.000in fb 781.20 psi fv 51.04 psi Left DL 0.65 k Max 1.46 k Fb 2,571.20 psi Fv 285.00 psi Right DL 0.95 k Max 2.12 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.077 in -0.177 in Deflection 0.000 in 0.000 in ...Location 6.804 ft 6.804 ft ...Length/Deft 0.0 0.0 ...Length/Deft 2,090.9 915.36 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.116 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 15.922 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 9.075 Cl 0.989 Max Moment Sxx Reg'd Allowable fb @ Center 8.03 k-ft 37.49 in3 2,571.20 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 2.19 k 3.18 k Area Required 7.674 in2 11.166 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.46 k Bearing Length Req'd 0.370 in Max. Right Reaction 2.12 k Bearing Length Req'd 0.539 in Title : Dsgnr: EE15i? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #2 General Timber Beam Job # -@ Date: 12:40PM, 15 JAN 06 Page 2 5b upper floors 1 57.ecw: Calculations Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.46 k 0.0000 in Q Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: A-Di ? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 er: KW-0606238, Ver5.8.0, 1-Dec-2003 1983-2003 ENERCALC Engineering Software Description Bm #3 General Timber Beam Page 1 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 11.75 ft .....Lu 7.00 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Trapezoidal Loads #1 DL @ Left 60.00 #/ft LL @ Left 80.00 #/ft Start Loc 4.000 ft DL @ Right 60.00 #/ft LL @ Right 80.00 #/ft End Loc 11.750 ft Point Loads Dead Load 400.0 Ibs Ibs Ibs Ibs Live Load 800.0 Ibs Ibs Ibs Ibs ...distance 4.000 ft 0.000 ft 0.000 ft 0.000 ft Summary - Span= 11.75ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0182 : 1 Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft Beam Design OK Maximum Moment 4.8 k-ft Maximum Shear " 1.5 Allowable 26.5 k-ft Allowable Max. Positive Moment 4.83 k-ft at 4.042 ft Shear: Max. Negative Moment -0.00 k-ft at 11.750 ft Max @ Left Support 0.00 k-ft Max @ Right Support 0.00 k-ft Max. M allow 26.47 Reactions... fb '469.83 psi fv 29.79 psi Left DL Fb 2,574.63 psi Fv 285.00 psi Right DL Deflections Camber: 1.9 k 17.8 k @ Left 1.24 k @ Right 1.22 k @ Left 0.000 in @ Center 0.049 in @ Right 5 0.000in 0.51 k' Max 1.24 k 0.54 k Max 1.22 k Center Span... Dead Load Total Load Left Cantilever... ueaa Loao I oral Loaa Deflection -0.033 in -0.080 in Deflection 0.000 in 0.000 in ...Location 5.734 ft 5.687 ft ...Length/Deft 0.0 0.0 ...Length/Dell 4,283.2 1,755.92 Right Cantilever... Camber ( using 1.5' D.L. DO ) Deflection 0.000 in 0.000 in @ Center 0.049 in ...Length/Defl 0.0 0.0 Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 14.303 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 8.601 Cl 0.990 Max Moment Sxx Reo'd Allowable fb @ Center 4.83 k-ft 22.52 in3 2,574.63 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 1.86 k 1.84 k Area Required 6.518 in2 6.446 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.24 k Bearing Length Req'd 0.314 in Max. Right Reaction 1.22 k Bearing Length Req'd 0.311 in Title : Dsgnr: fEni? Description Scope : Job # @ Date: 12:40PM, 15 JAN 06 Rev: seoooa Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983.2003 ENERCALC Engineering Software Sb upper floor s157.ecw:Calculations Description Bm #3 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.24 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: /Eni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #4 Multi-Span Timber Beam Beam Width in 6.750 6.750 6.750 Beam Depth in 15.000 15.000 15.000 End Fixity Pin - Pin Pin - Pin Pin - Free Le: Unbraced Length ft 4.50 5.75 4.00 Member Type GluLam GluLam GluLam Job # @ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor s157.ecw:Calculations Loads Live Load Used This Span ? Yes Yes Yes Dead Load #/ft 205.00 430.00 430.00 Live Load #/fti 270.00 865.00 865.00 Results Mmax @ Cntr in-k @X= ft Max @ Left End in-k Max @ Right End in-k fb : Actual psi Fb : Allowable psi Shear @ Left k Shear @ Right k fv : Actual psi Fv : Allowable psi 41.1 0.0 U.U 3.78 0.00 4.00 0.0 -36.0 -124.3 -36.0 -124.3 0.0 162.4 491.1 491.1 2,389.0 2,385.6 2,390.3 Bending OK Bending OK Bending OK 1.80 2.44 5.18 2.47 5.00 0.00 27.7 49.8 53.2 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k 0.78 1.93 W 3.33 LL @ Left k 1.02 2.99 6.85 Total @ Left k 1.80 4.91 10.18 DL @ Right k 1.93 3.33 0.00 LL @ Right k 2.99 6.85 0.00 Total @ Right ki, 4.91 10.18 0.00 Max. Deflection in -0.014 0.005 -0.049 @ X = ft 4.14 3.76 4.00 Query Values Location ft 0.00 0.00 0.00 Moment in-k 0.0 -36.0 -124.3 Shear k I 1.8 2.4 5.2 Deflection in 0.0000 0.0000 0.0000 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #5 General Information Douglas Fir, 24F - V8 Spans Considered Continuous Over Support Timber Member Informa tion Description Span ft 5.75 Timber Section 6.75x15 Beam Width in 6.750 Beam Depth in l 15.000 End Fixity ft Pin - Pin 75 5 Le: Unbraced Length . Member Type GluLam Live Load Used This Span ? Yes Dead Load #/ft 420.00 1 ive Load #/fti 560.00 Title : Dsgnr: `Eni? Description Scope : Multi-Span Timber Beam Job # : @ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor sl57.ecw: Calculations Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Fb : Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Fv : Basic Allow 240.0 psi Load Duration Factor 1.000 3.25 4.25 6.75x15. 6.75x15 6.750 6.750 15.000 15.000 Pin - Pin Pin - Free 3.25 4.25 GluLam GluLam Yes Yes 420.00 400.00 560.00 800.00 Results Mmax @ Cntr in-k i 2 .2 00.0 0 0 0.0 25 4 @X= ft . . Max @ Left End in-kl 0.0 -13.2 -130.0 Max @ Right End in-k -13.2 -130.0 0.0 fb : Actual psi 166.9 513.8 513.8 Fb : Allowable psi 2,385.6 2,392.2 2,389.6 Bending OK Bending OK Bending OK Shear @ Left k l 2.63 1.40 5.10 00 0 Shear @ Right k , 3.01 4.59 . fv : Actual psi 26.2 49.7 53.4 Fv : Allowable psi I 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k 1.09 1.09 3.29 LL @ Left k 1.53 0.51 6.40 Total @ Left k 2.63 1.60 9.69 DL @ Right k 1.09 3.29 40 6 0.00 00 0 LL @ Right k 0.51 . . Total @ Right n 1.60 9.69 0100 Deflection Max inl -0.006 0.004 -0.051 . @ X = ft i 2.80 1.88 4.25 query Values Location ft 0.00 0.00 0.00 Moment in-ki 0.0 -13.2 130.0 Shear k' 2.6 -1.4 5.1 Deflection in! 0.0000 0.0000 0.0000 Title : Dsgnr: FEni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #6 Page 1 5b uooer floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name 6.75x15 Center Span 8.00 ft .....Lu 8.00 ft Beam Width 6.750 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 15.000 in Right Cantilever 7.25 ft .....Lu 7.25 ft Member Type GluLam Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi Load Dur. Factor 1.000 Fv Allow 240.0 psi Beam End Fixity Pin-Pin Fc Allow 650.0 psi E 1,700.0 ksi Full Length Uniform Loads Center DL 220.00 #/ft LL 290.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL 445.00 #/ft LL 885.00 #/ft General Timber Beam Job # @ Date: 12:40PM, 15 JAN 06 Span= 8.00ft, Right Cant= 7.25ft, Beam Width = 6.750in x Depth = 15.in, Ends are Pin-Pin Max Stress Ratio 0.697 : 1 Maximum Moment -35.0 k-ft Maximum Shear * 1.5 Allowable 50.2 k-ft Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support Max @ Right Support Max. M allow fb 1,657.08 psi Fb 2,379.07 psi 0.33 k-ft at 1.152 ft -11.70 k-ft at 8.000 ft 0.00 k-ft -34.95 k-ft 50.18 Reactions... fv 141.64 psi Left DL Fv 240.00 psi Right DL Shear: @ Left @ Right Camber: @ Left @ Center @ Right -0.58 k Max 5.57 k Max Deflections Beam Design OK 14.3 k 24'.3 k 3.49 k 9.56 k 0.000 in 0.030 in 0.274 in -2.33 k 16.05 k Center Span... Dead Load Total Load Lett Cantilever... ueao Loac I oral Loaa Deflection 0.020 in 0.012 in Deflection 0.000 in 0.000 in ...Location 4.848 ft 5.333 ft ...Length/Defl 0.0 0.0 ...Length/Deft 4,881.3 7,945.86 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection -0.183 in -0.584 in @ Center 0.030 in ...Length/Dell 952.1 297.8 @ Left 0.000 in @ Right 0.274 in Stress Calcs Bending Analysis Ck 21.584 Le 16.473 ft Sxx 253.125 in3 Area 101.250 in2 Cv 1.000 Rb 8.069 Cl 0.991 Max Moment Sxx Req'd Allowable fb @ Center 11.70 k-ft 58.99 in3 2,379.07 psi @ Left Support 0.00 k-ft 0.00 in3 2,400.00 psi @ Right Support 34.95 k-ft 176.14 in3 2,381.30 psi Shear Analysis @ Left Support @ Right Support Design Shear 5.23 k 14.34 k Area Required 21.808 in2 59.755 in2 Fv: Allowable 240.00 psi 240.00 psi Bearing @ Supports Max. Left Reaction -2.33 k Bearing Length Req'd 0.531 in Max. Right Reaction 16.05 k Bearing Length Req'd 3.659 in Title : Dsgnr: EEtii? Description Scope : Job # @ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 2 11 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software Sb upper floor s157_ecw:Calculations Description Bm #6 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft -2.33 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft -2.33 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: FEni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #7 General Timber Beam Job # G-@ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 9.67 ft .....Lu 2.00 ft Beam Width 5.250 in Left Cantilever 2.17 ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever it .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Point Loads Dead Load 1,800.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs Live Load 5,600.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 2.170 It 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft _v4 Summary Beam Design OK Span= 9.67ft, Left Cant= 2.17ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.627 : 1 Maximum Moment -16.1 k-ft Maximum Shear * 1.5 11.1 k Allowable 26.7 k-ft Allowable 17.8 k Max. Positive Moment 0.00 k-ft at 0.000 ft Shear: @ Left 7.43 k Max. Negative Moment -3.94 k-ft at 0.000 ft @ Right 1.59 k Max @ Left Support -16.09 k-ft Camber: @ Left 0.059 in Max @ Right Support 0.00 k-ft @ Center 0.041 in @ Right 0.000 in Max. M allow 26.67 Reactions... fb 1,565.17 psi fv 178.82 psi Left DL 2.31 k Max 9.17 k Fb 2,593.50 psi Fv 285.00 psi Right DL -0.33 k Max -1.59 k Deflections Center Span... Dead Load Total Load Left Cantilever... ueaa Loaa I otat Loaa Deflection 0.027 in 0.027 in Deflection -0.040 in -0.166 in ...Location 4.010 ft 4.010 ft ...Length/Deft 1,317.2 313.6 ...Length/Defl 4,254.2 4,254.18 Right Cantilever... Camber ( using 1.5 * D.L. DO ) Deflection 0.000 in 0.000 in @ Center 0.041 in ...Length/Dell 0.0 0.0 @ Left 0.059 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 4.615 Cl 0.997 Max Moment Sxx Read Allowable fb @ Center 3.94 k-ft 18.24 in3 2,593.50 psi @ Left Support 16.09 k-ft 74.28 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 11.15 k 2.39 k Area Required 39.117 in2 8.374 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 9.17 k Bearing Length Req'd 2.329 in Max. Right Reaction -1.59 k Bearing Length Req'd 0.404 in Title : Dsgnr: FEni? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software 77720 -z Description Bm #7LL General Timber Beam Page 2 5b upper floor s157.ecw:Calculations Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 16.09 k-ft 1.74 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 16.09 k-ft 1.74 k 0.0000 in Title : Dsgnr: AEni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #8 Page 1 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Center Span 9.67 ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever 2.17ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Point Loads Dead Load 120.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs Ib Live Load 160.0 Ibs ...distance -2.170 ft Ibs 0.000 ft Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft s Ibs 0.000 ft 0.000-ft Summary Beam Design OK Span= 9.67ft, Left Cant= 2.17ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.038 : 1 Maximum Moment -0.6 k-ft Maximum Shear 1.5 0.5 k Allowable 17.7 k-ft Allowable 11.8 k Max. Positive Moment 0.02 k-ft at 7.736 ft Shear: ft @ Left @ Right 0.30 k 0.02 k Max. Negative Moment -0.28 k-ft at 0.000 Max @ Left Support -0.63 k-ft Camber: @ Left 0.004in Max @ Right Support 0.00 k-ft @ Center 0.002in @ Right 0.000in Max. M allow 17.72 Reactions... fb 92.11 psi fv 10.88 psi Left DL 0.22 k Max 0.42 k Fb 2,584.51 psi Fv 285.00 psi Right DL 0.02 k Max 0.02 k Deflections Center Span... Dead Load Total Load Left Cantilever... Deaa Load Total Load Deflection 0.001 in 0.001 in Deflection -0.003 in -0.008 in ...Location 2.877 ft 2.877 ft ...Length/Deft 17,817.8 6,208.6 ...Length/Defl 96,470.7 96,470.68 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.002 in ...Length/Defl 0.0 0.0 @ Left 0.004 in @ Right 0.000 in Stress Calcs General Timber Beam Bending Analysis Ck 21.924 Le Cf 1.000 Rb @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 4.118 ft 6.923 Max Moment 0.28 k-ft 0.63 k-ft 0.00 k-ft @ Left Support 0.45 k 1.586 in2 285.00 psi 0.42 k 0.02 k Sxx 82.259 in3 Cl 0.994 Sxx Req'd 1.32 in3 2.91 in3 0.00 in3 @ Right Support 0.03 k 0.102 in2 285.00 psi Area 41.563 in2 Allowable fb 2,584.51 psi 2,600.00 psi 2,600.00 psi Bearing Length Req'd 0.158 in Bearing Length Req'd 0.007 in Job # @ Date: 12:40PM, 15 JAN 06 Title : Dsgnr: IEM? Description : Scope : Genera! Timber Beam Rev: 580004 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #8 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft -0.63 k-ft 0.11 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft -0.63 k-ft 0.11 k 0.0000 in Job # 77 @ Date: 12:40PM, 15 JAN 06 Page 2 5b upper floor s157.ecw:Calculations Title : Dsgnr: FEni? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software Sb upper floors 157.ecw:Calculations amn+xs~~°' i Description Bm #9 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 13.00 ft .....Lu 2.00 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Full Length Uniform Loads Center DL 180.00 #/ft LL 240.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Point Loads Dead Load 200.0 Ibs Ibs Ibs Ibs Ibs IDS lus Live Load 200.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 5.170 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.0 00 ft 0.000 ft Summary Beam Design OK Span= 13.00ft, Beam Width = 5.250in x Depth = 11.875in, E nds are Pin-Pin Max Stress Ratio 0.385 ; 1 Maximum Moment 10.3 k-ft Maximum Shear * 1.5 4.6 k Allowable 26.7 k-ft Allowable 17.8 k Positive Moment Max 10.26 k-ft at 6.136 ft Shear: @ Left 3.07 k . Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 2.99 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.151 in @ Right. O.000in Max. M allow 26.67 Reactions... fb 997.40 psi fv 73.85 psi Left DL 1.39 k Max 3.07 k Fb 2,593.50 psi Fv 285.00 psi Right DL 1.35 k Max 2.99 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.101 in -0.222 in Deflection 0.000 in 0.000 in ...Location 6.448 ft 6.448 ft ...Length/Deft 0.0 0.0 ...Length/Deft 1,547.7 701.77 Right Cantilever... Camber ( using 1.5 * D.L. Deft ) Deflection 0.000 in 0.000 in @ Center 0.151 in ...Length/Defi 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Title : Job # '-,-@ Dsgnr: fEni? Date: 12:40PM, 15 JAN 06 Description Scope Rev: 580004 Page 2 - User:KW-0606238,Ver 5.8.0, 9-Dec-2003 General Timber Beam 5b upper floor s957.ecw:Calculations (cj9983.2003 ENERCALC Engineering Software Description Bm #9 Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 4.615 t CI 0.997 Sxx Reg'd Allowable fb @ Center Max Momen 10.26 k-ft 47.45 in3 2,593.50 psi @ Left Support 0.00 k-ft 0.00 in3 00 in3 0 2,600.00 psi 2,600.00 psi @ Right Support 0.00 k-ft . Shear Analysis @ Left Support @ Right Support Design Shear 4.60 k 4.48 k Area Required 16.155 in2 15.724 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports 07 k 3 Bearing Length Req'd 0.780 in Max. Left Reaction . 99 k 2 Bearing Length Req'd 0.759 in Max. Riqht Reaction . Query Values M, V, & D @ Specified Locations @ Center Span Location = 0.00 ft @ Right Cant. Location = 0.00 ft @ Left Cant. Location = 0.00 ft Moment 0.00 k-ft 0.00 k-ft 0.00 k-ft Shear 3.07 k 0.00 k 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in Title : Dsgnr: FEnf? Description : Scope : Job # ---@ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 1 18 User: KW-0606238,Ver 5.8.0, 1-Dec-2003 General Timber Beam (67983-2003 ENERCALC Engineering Software 5b upper floor s157.ecw:Calculations Description Bm #10 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined III Section Name MicroLam: 5.25x11.87 Center Span 11.00 ft .....Lu 2.00 ft Beam Width 7.000 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Point Loads Dead Load 5,000.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs Live Load 14,100.0 Ibs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 0.670 it 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft Summary Overstressed in Shear ! Span= 11.00ft, Beam Width = 7.000in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 1 .143 : 1 Maximum Moment 12.1 k-ft Maximum Shear * 1.5 27.1 k . Allowable 35.6 k-ft Allowable 23.7 k Max. Positive Moment 12.05 k-ft at 0.704 ft Shear: @ Left 18.05 k Max. Negative Moment 0.00 k-ft at 11.000 ft @ Right 1.27 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.041 in @ Right 0.000in Max. M allow 35.60 Reactions... fb 879.02 psi fv 325.67 psi Left DL 4.81 k Max 18.05 k Fb 2,596.41 psi Fv 285.00 psi Right DL 0.42 k Max 1.27 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.028 in -0.095 in Deflection 0.000 in 0.000 in ...Location 4.796 ft 4.708 ft ...Length/Defl 0.0 0.0 ...Length/Deft 4,787.0 1,382.83 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.041 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 164.518 in3 Area 83.125 in2 Cf 1.000 Rb 3.461 Cl 0.999 Max Moment Sxx Reo'd Allowable fb @ Center 12.05 k-ft 55.70 in3 2,596.41 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 27.07 k 1.91 k Area Required 94.988 in2 6.708 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 18.05 k Bearing Length Req'd 3.438 in Max. Right Reaction 1.27 k Bearing Length Req'd 0.243 in Title : Dsgnr: FEni? Description : Scope : Job # -7,@ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983.2003 ENERCALC Engineering Software 5b upper floor s157.ecw:Calculations Description Bm #10 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 18.05 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: /EnY? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 Rev: 580004 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (61983-2003 ENERCALC Engineering Software Description Bm #10 for shear calculation reduction rage i 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 11.00 ft .....Lu 2.00 ft 00 ft 0 Beam Width 7.000 in Left Cantilever . ft .....Lu 00 ft Lu 0 ft Beam Depth 11.875 in Right Cantilever . Member Type Manuf/So.Pine Truss Joist - MacMillan, Microl-am 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Point Loads _ 390.0 Ibs Dead Load 3 Ibs Ibs Ibs Ibs Ibs Ibs , Live Load 9,550.0 Ibs ...distance 0.670 ft Ibs Ibs Ibs Ibs Ibs Ibs 0.000 It 0.000 ft 0.000 It 0.000 ft 0.000 ft 0.000ft Summary i P Beam Design OK 11.OOft, Beam Width = 7.000in x Depth = 11.875in, Ends are Pin-Pin Span= Max Stress Ratio 0.776 : 1 2 k-ft Maximum Shear' 1.5 8 18.4 k Maximum Moment Allowable . 35.6 k-ft Allowable 23.7 k Max. Positive Moment 8.19 k-ft at 0.704 ft Shear: f @ Left @ Right 12.26 k 0.90 k Max. Negative Moment t 0.00 k-ft at 11.000 Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.030in 000in O @ Right . Max. M allow 35.60 Reactions... fb 597.25 psi fv 221.29 psi Left DL 3.29 k Max 12.26 k Fb 2,596.41 psi Fv 285.00 psi: Right DL 0.32 k Max 0.90 k Deflections Center Span... Dead Load Total Load Left Cantilever Dead Load Total Load Deflection -0.020 in -0.066 in Deflection 0.000 in 0.000 in ...Location 4.840 ft 4.708 ft ...Length/Deft 0.0 0.0 ...Length/Defl 6,657.3 2,006.13 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.030 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 164.518 in3 Area 83.125 in2 Cf 1.000 Rb 3.461 Cl 0.999 Max Moment Sxx Reci'd Allowable fb @ Center 8.19 k-ft 37.84 in3 2,596.41 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 18.39 k 1.35 k Area Required 64.542 in2 4.733 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 12.26 k Bearing Length Req'd 2.336 in Max. Right Reaction 0.90 k Bearing Length Req'd 0.171 in General Timber Beam -s:. Title : Dsgnr: IFni? Description : Scope Job # ,@ Date: 12:40PM, 15 JAN 06 Rev: s8oooa Page 2 User: KW-060623Ver 5.8.0, 1-Dec-2003 General Timber Beam Sbupperfloors157.ecw:Calculations (c)1983-2003 ENERCALC Engineering Software Description BM #10 for shear calculation reduction Ouerv Values Moment Shear Deflection M, V, & D @ Specified Locations 0.0000 in @ Center Span Location = 0.00 It 0.00 k-ft 12.26 k @ Right Cant. Location 0.00 ft 0.00 k-ft 0.00 k 0.0000 in = 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft Title : Dsgnr: /Ehf? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Description Bm #11 General Timber Beam Job # @ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor 5157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 10.00ft .....Lu 2.00 ft Beam Width 5.250 in Left Cantilever 5.67ft .....Lu 5.67 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Full Length Uniform Loads Center DL #/ft LL #/ft Left Cantilever DL 215.00 #/ft LL 290.00 #/ft Right Cantilever DL #/ft LL #/ft Trapezoidal Loads #1 DL @ Left 215.00 #/ft LL @ Left 290.00 #/ft Start Loc 0.000 ft DL @ Right 215.00 4/ft LL @ Right 290.00 #/ft End Loc 3.750 ft #2 DL @ Left 325.00 #/ft LL @ Left 430.00 #/ft Start Loc 3.750 ft DL @ Right 325.00 #/ft LL @ Right 430.00 #/ft End Loc 10.000 ft Summary Beam Design OK Span= 10.00ft, Left Cant= 5.67ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.331 ; 1 Maximum Moment -8.4 k-ft Maximum Shear * 1.5 5.9 k Allowable 26.5 k-ft Allowable 17.8 k Max. Positive Moment 7.09 k-ft at 5.687 ft Shear: @ Left 3.93 k Max. Negative Moment -3.70 k-ft at 0.000 ft @ Right 3.31 k Max @ Left Support -8.36 k-ft Camber: @ Left 0.054in Max @ Right Support 0.00 k-ft @ Center 0.033in @ Right 0.000in Max. M allow 26.53 Reactions... fb 813.15 psi fv 94.44 psi Left DL 3.04 k Max 6.87 k Fb 2,579.93 psi Fv 285.00 psi Right DL 1.25 k Max 3.31 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.022 in -0.084 in Deflection -0.036 in -0.191 in ...Location 5.812 ft 5.312 ft ...Length/Deft 3,772.7 712.2 ...Length/Deft 5,515.3 1,43202 Right Cantilever... Camber ( using 1.5 D.L . DO ) Deflection 0.000 in 0.000 in @ Center 0.033 in ...Length/Dell 0.0 0.0 @ Left 0.054 in @ Right 0.000 in Title : Dsgnr: FEni? Description Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Description Bm #11 General Timber Beam Page 2 5b upper floor sl57.ecw: Calculations Stress Calcs Bending Analysis Ck 21.924 Le 11.676 ft Sxx Cf 1.000 Rb 7.771 Cl Max Moment @ Center 7.09 k-ft @ Left Support 8.36 k-ft @ Right Support 0.00 k-ft Shear Analysis @ Left Support Design Shear 5.89 k Area Required 20.659 in2 Fv: Allowable 285.00 psi Bearing @ Supports Max. Left Reaction 6.87 k M x Ri ht Reaction 3.31 k 123.389 in3 0.997 Sxx Req'd 32.81 in3 38.89 in3 0.00 in3 @ Right Support 4.96 k 17.395 in2 285.00 psi Bearing Length Req'd Bearing Length Req'd a. g Query Values M, V, & D @ Specified Locations Moment @ Center Span Location = 0.00 ft -8.36 k-ft @ Right Cant. Location = 0.00 ft 0.00 k-ft @ Left Cant., Location = 0.00 ft -8.36 k-ft A- I Area 62.344 in2 Allowable fb 2,593.50 psi 2,579.93 psi 2,600.00 psi Job # @ Date: 12:40PM, 15 JAN 06 1,746 in 0.839 in Shear 3.93 k 0.00 k 3.93 k Deflection 0.0000 in 0.0000 in 0.0000 in Title : Dsgnr: EEni? Description : Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #12 General Timber Beam Job # @ Date: 12:40PM, 15 JAN 06 Page 1 5b upper floor s157.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3.5x11.875 Full Beam Width 3.500 in Beam Depth 11.875 in Member Type Manuf/So.Pine Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000pcf Length Uniform Loads Center Span 9.5o ft .....Lu 2.00 ft Left Cantilever ft .....Lu 0.00 ft 00 ft 0 L Right Cantilever . u ft Truss Joist - MacMillan, MicroLam 1.9 E Fb Base Allow 2,600.0 psi Fv Allow 285.0 psi Fc Allow 750.0 psi E 1,900.0 ksi Center DL 60.00 #/ft LL Left Cantilever DL #/ft LL Right Cantilever DL #/ft LL Summary Span 9.50ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.169 : 1 Maximum Moment 3.0 k-ft Maximum Shear " 1. Allowable 17.7 k -ft Allowable ft t 4 750 ft Shear: Max. Positive Moment Max. Negative Moment 2.99 k- a 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k-ft Camber: Max @ Right Support 0.00 k-ft Max. M allow 17.72 Reactions... fb 436.28 psi fV 45.45 psi Left DL 0.33 k Fb 2,584.51 psi Fv 285.00 psi Right DL 0.33 k 1.9 k 11.8 k @ Left 1.26 k @ Right 1.26 k @ Left 0.000 in @ Center 0.021 in @ Right 0.000 in Max 1.26 k Max 5 1.26 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load 000 in 0 Total Loa 0.000 in Deflection 0.014 in -0.052 in Deflection 750 ft Length/Deft 4 . 0.0 0.0 ...Location 4.750 ft . ...Length/Deft 8,234.7 2,177.55 Right Cantilever... 000 in 0 0.000 in Camber ( using 1.5 * D.L. Defl ) Deflection Length/Deft . 0.0 0.0 @ Center 0.021 in @ Left 0.000 in @ Right 0.000 in Bending Analysis 924 Le 21 118 ft 4 Sxx 82.259 in3 Area 41.563 in2 . Ck Cf 1.000 Rb . 6.923 Cl 0.994 Sxx Reo'd Allowable fb @ Center Max Moment 2.99 k-ft 13.89 in3 2,584.51 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi 00 psi 600 2 @ Right Support 0.00 k-ft 0.00 in3 . , Shear Analysis @ Left Support @ Right Support Design Shear 1.89 k 1.89 k Area Required 6.628 in2 6.628 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports 26 k 1 Bearing Length Req'd 0.480 in Max. Left Reaction . 26 k 1 Bearing Length Req'd 0.480 in Max. Right Reaction . 195.00 #/ft #/ft #/ft Beam Design ulc Title : Dsgnr: fEni? Description : Scope : User: KW-0606238, Ver 5.8.0. 1-Dec-2003 (c)1983.2003 ENERCALC Engineering Software Description Bm #12 General Timber Beam Job # -1 -1 @ Date: 12:40PM, 15 JAN 06 Page 2 5b upper floor s157.ecw:Calculations Query Values T M, V, & D @ Specified Locations Moment Shear Deflection Center Span Location = 0.00 ft 0.00 k-ft 1.26 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Title : Dsgnr: /Enf? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 Rev: 580004 Page 1 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineering Software 5b upper floor s157 ecw:Calculations Description Bm #13 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam:3.5x11.875 Center Span 10.00ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Point Loads Dead Load 230.0lbs 230.01bs Ibs Ibs Ibs Ibs Ibs Live Load 770.0 Ibs 770.0 Ibs Ibs Ibs Ibs Ibs Ibs ...distance 2.170 ft 7.830 ft •0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000ft Summary Beam Design OK Span= 10.00ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.133 : 1 Maximum Moment 2.3 k-ft Maximum Shear * 1.5 1.6 k Allowable 17.7 k-ft Allowable 11.8 k Max. Positive Moment 2.30 k-ft at 5.000 ft Shear: @ Left 1.05 k Max. Negative Moment 0.00 k-ft at 10.000 ft @ Right 1.05 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.020 in @ Right 0.000in Max. M allow 17.72 Reactions... fb 334.98 psi fV 37.91 psi Left DL 0.28 k Max 1.05 k Fb 2,584.51 psi Fv 285.00 psi Right DL 0.28 k Max 1.05 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.013 in -0.050 in Deflection 0.000 in 0.000 in ...Location 5.000 ft 5.000 ft ...Length/Deft 0.0 0.0 ...Length/Dell 8,997.7 2,410.30 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.020 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le 4.118 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 6.923 Cl 0.994 Max Moment Sxx Read Allowable fb @ Center 2.30 k-ft 10.66 in3 2,584.51 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 1.58 k 1.58 k Area Required 5.529 in2 5.529 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 1.05 k Bearing Length Req'd 0.400 in Max. Right Reaction 1.05 k Bearing Length Req'd 0.400 in Title : Dsgnr: FEni? Description : Scope : Job # @ Date: 12:40PM, 15 JAN 06 1-Dec-2003 ineering Software General Timber Beam Description Bm #13 5b Page 2 oer floor s157.ecw:Calculations [Query Values EN - M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 1.05 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Monroe & Newell OF- CALCULATED Inc. SHEET NO. CALCULATED BY DATE CHECKED BY DATE ,off ,e, 59e l 01218 110-.4b . - ~f Olas .O-.r , .O-.b ~.t/I b rf Ol T"8 if An 40 in . ~J J (JV J ' Na maN maJ 0 ~ m I f _ d m I:,I m m - i M~ I Ni ii) A ~..A If- n /1 S ~I I ~ y w w i ry W mLL mN N "Ilb I tell I - ~ L a ~ I n ~ I r, I I sue- Orr C ~ III I' ~ i x ,y a ~ I ~ III S I r p I' iI; ~I ~ aS ~ I .3k3 it ~ I l i n ~ 'I i I MT- III - ~ ~~{p~ I 42 `I y r ~Z2 JOB Monroe & Newell < OF Engineers, Inc. SHEET No. CALCULATED BY DATE -1 CHECKED BY DATE SCALE , a , ~7 +--7 A Monroe & Newell Engineers, Inc. T .106 y;' T~! SHEET NO. OF CALCULATED BY DATE ~az t - _j 1 F CHECKED BY DATE SCALE PRODUCT 294-1 (Single Sheets) 205-1 (Padded) 4/ Monroe & Newell Engineers, Inc. 4s-' 4 SHEET NO. OF y , CALCULATED BY * t{-°t DATE I y''?~~" CHECKED BY DATE SCALE Monroe & Newell JOB Engineers, Inc. SHEET NO. l OF CALCULATED BY DATE--J-2,-J- Q CHECKED BY DATE SCALE P-58Co _ P Monroe & Newell JOB . OF Engineers, Inc. SHEET NO. r CALCULATED BY •-^°°v! DATE o C-, CHECKEDBY DATE Monroe & Newell Engineers, Inc. JOB SHEET NO. OF CALCULATED BY DATE s CHECKED BY SCALE DATE 1 l f, i 7 (ri 4:7L L 4 DL,. l:Z_ L4 0- l T, Wy, ~ , 0 Li t 3, -7 k L 0i f L ~ awl ' - _ 4 . , , c 1 _ w I~ II1= i k56~ r- Monroe & Newell 106 Engineers, Inc. SHEET NO. ~I - OF 77CALCULATED BY DATE I Y7 CHECKEDBY DATE SCALE 4 a,onrE _ -p,g _ . I ' trs i 17 2 `i ' ? 7e 0_ i ~ w_ , . _VL , J ~ . . Monroe & Newell Engineers, Inc. JOB SHEET NO. - CALCULATED BY r CHECKED BY SCALE DATE DATE ` ik 4 MAX 4140 ivtl- =47:~2 111 Monroe & Newell c~ Engineers, Inc. SHEET NO. OF CALCULATED BY DATE 3 CHECKED BY DATE SCALE P-5611 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Hev: 580004 - - User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 1 (c)1983.2003 ENERCALC Engineering Software 5b roof.ecw:Calculations Description Bm #1.1 Simple Span General information Section Name 8.75x22.5 Beam Width Beam Depth Member Type Bm Wt. Added to Loads Load Dur. Factor Beam End Fixity Wood Density Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Center Span 4.50 ft .....Lu 8.750 in Left Cantilever 0.75ft .....Lu 22.500 in Right Cantilever ft .....Lu GluLam Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi 1.000 Fv Allow 240.0 psi Pin-Pin Fc Allow 650.0 psi 35.000 pcf E 1,700.0 ksi 2.00 ft 0.75 ft 0.00 ft Full Length Uniform Loads Center DL Left Cantilever DL Right Cantilever DL 210.00 #/ft LL 700.00 #/ft 210.00 #/ft LL 700.00 #/ft #/ft LL #/ft - ' - Beam Design OK Span= 4.50ft, Left Cant= 0 .75ft, Beam Width = 8.750in x Depth = 22.5in, Ends are Pin-Pin Max Stress Ratio 0.070 : 1 Maximum Moment 2.4 k-ft Maximum Shear * 1.5 3.3 k Allowable 147.4 k-ft Allowable 47.3 k Max. Positive Moment 2.39 k-ft at 2.260 It Shear: @ Left 2 22 k Max. Negative Moment -0.07 k-ft at 0.000 ft @ Right . 2.14 k Max @ Left Support -0.27 k-ft Camber: @ Left 0.000in Max @ Right Support 0.00 k-ft @ Center 0.000in Max. M allow 147.40 Reactions @ Right 0.000in fb 38.82 psi fv 16.88 psi Left DL 0.79 k Max 2.93 k Fb 2,395.83 psi Fv 240.00 psi Right DL 0.56 k Max 2.14 k De flections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.000 in -0.001 in Deflection 0.000 in 0.000 in ...Location 2.281 ft 2.260 ft ...Length/Deft 234,185.9 57,261.1 ...Length/Deft 343,362.3 87,854.82 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.000 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis . Ck 21.584 Le 4.118 ft Sxx 738.281 in3 Area 196.875 in2 Cv 1.000 Rb 3.812 CI 0.998 Max Moment Sxx Read Allowable fb @ Center 2.39 k-ft 11.96 in3 2,395.83 psi @ Left Support 0.27 k-ft 1.35 in3 2,398.47 psi @ Right Support 0.00 k-ft 0.00 1n3 2,400.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 3.32 k 3.21 k Area Required 13.844 in2 13.369 in2 Fv: Allowable 240.00 psi 240.00 psi Bearing @ Supports Max. Left Reaction 2.93 k Bearing Length Req'd 0.516 in Max. Right Reaction 2.14 k Bearing Length Req'd 0.376 in Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : nev: 00v U4 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 2 (c)1983-2003 ENERCALC Engineering Software 5b roof.ecw:Calculations Description Bm #1.1 Simple Span Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft -0.27 k-ft 2.22 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft -0.27 k-ft 2.22 k 0.0000 in Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 Building #5 Dsgnr: Date: 11:35AM, 11 JAN 06 Unit #58 Description : Building #5, Unit #5B Scope Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Multi -S an Timber Beam Page 1 (c)1983-2003 ENERCALC Engineering Software 5b roof.ecw:Calculations Description Bm #1 multi-span General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Douglas Fir, 24F V8 Fb Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Spans Considered Continuous Over Support Fv Basic Allow 240.0 psi Load Duration Factor 1.000 l limber memner information Description Span Timber Section Beam Width i Beam Depth i, End Fixity Le: Unbraced Length 1 Member Type Loads Live Load Used This Span ? Dead Load #/f Live Load #/f Dead Load #/ft Live Load #/ft Start ft End fl Dead Load @ Left #/f1 Dead Load @ Right #/ft Live Load @ Left #/ft Live Load @ Right #/ft Start ft End ft Point #1 Dead Load Ibs Live Load Ibs @ X ft 0.75 4.50 25.75 8.75x22.5 8.75x22.5 8.75x22.5 8.750 8.750 8.750 22.500 22.500 22.500 Free - Pin Pin - Pin Pin - Pin 0.75 2.00 2.00 Sawn Sawn Sawn Yes Yes Yes 140.00 210.00 460.00 700.00 210.00 700.00 0.750 4.500 11.500 310.00 310.00 1,025.00 1,025.00 11.500 0.750 4.500 25.750 1,600.00 4,900.00 11.500 t(esults Mmax @ Cntr in-k 0.0 0.0 988.1 @ X = ft 0.00 0.00 14.59 Max @ Left End in-k l 0.0 -2.0 -1 289.2 Max @ Right End in-k 2.0 -1,289.2 , 0.0 fb : Actual psi i 2.7 1,746.3 1,746.3 Fb : Allowable psi 2,236.2 2,233.0 2,233.0 Bending OK Bending OK Bending OK Shear @ Left k l 0.00 21.79 21.16 Shear @ Right k 0.45 25.88 14.83 fv : Actual psi ! 0.0 184.1 149.3 Fv : Allowable psi 240.0 240.0 240.0 I _ Shear OK Shear OK Shear OK rseaciions & UeTlectlon DL @ Left k LL @ Left k Total @ Left k DL @ Right k LL @ Right k Total @ Right k Max. Deflection in @X= ft 0.00 -5.03 11.05 0.00 -16.31 36.00 0.00 -21.34 47.05 -5.03 11.05 3.47 -16.31 36.00 11.36 -21.34 47.05 14.83 -0.007 0.017 -0.555 0.00 2.61 14.25 vuery values Vail Front Door Residences Building #5 Unit #5B (Z15:>6/q Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : User; KW-0606238, Ver5.8.0, 1-Dec-2003 Multi- S an Timber Beam Page 2 (c)1983-2003 ENERCALC Engineering Software 5b roof ecw Calculations Description Bm #1 multi-span Location fti 0.00 0.00 0.00 Moment in-k 0.0 -2.0 -1,289.2 Shear k 0.0 -21.8 21.2 Deflection in i -0.0071 0.0000 0.0000 Vail Front Door Residences Building #5 Unit #5B eSB 15 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : sec KW-0606238, Ver 5.8.0, 1-Dec-2003 1983-2003 ENERCALC Engineering Software Description Bm #2 General Timber Beam General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name 8.75x22.5 Center Span 23.75 ft .....Lu 2.00 ft Beam Width 8.750 in Left Cantilever 6.50 ft .....Lu 2.50 ft Beam Depth 22.500 in Right Cantilever ft .....Lu 0.00 ft Member Type GluLam Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi Load Dur. Factor 1.000 Fv Allow 240.0 psi Beam End Fixity Pin-Pin Fc Allow 650.0 psi E 1,700.0 ksi Full Length Uniform Loads Center DL #/ft LL #/ft Left Cantilever DL 230.00 #/ft LL 765.00 #/ft Right Cantilever DL #/ft LL #/ft Trapezoidal Loads #1 DL @ Left 165.00 #/ft LL @ Left 550.00 #/ft Start Loc 0.000 ft DL @ Right 165.00 #/ft LL @ Right 550.00 #/ft End Loc 10.500 ft #2 DL @ Left 220.00 #/ft LL @ Left 725.00 #/ft Start Loc 10.500 ft DL @ Right 220.00 #/ft LL @ Right 725.00 #/ft End Loc. 23.750 ft ummary Beam Design OK Span= 23.75ft, Left Cant= 6.50ft, Beam Width = 8.750 in x Depth = 22.5in, Ends are Pin-Pin Max Stress Ratio 0.449 ; 1 Maximum Moment 58.1 k-ft Maximum Shear * 1.5 15.7 k Allowable 129.6 k-ft Allowable 47.3 k Max. Positive Moment 58.15 k-ft at 12.659 ft Shear: @ Left 10.23 k Max. Negative Moment -4.86 k-ft at 0.000 ft @ Right 10.48 k Max @ Left Support -21.02 k-ft Camber: •@ Left 0.072 in Max @ Right Support 0.00 k-ft @ Center 0.119in @ Right 0.000 in Max. M allow 129.58 Reactions... fb 945.16 psi fv 79.87 psi Left DL 3.86 k Max 16.69k Fb 2,106.22 psi Fv 240.00 psi Right DL 2.28 k Max 10.48 k Deflections Center Span... Dead Load t otai Loao uert t,anmever.., vcau waU J vtai LV- Deflection -0.079 in -0.411 in Deflection 0.048 in 0.326 in ...Location 12.418 ft 12.056 ft ...Length/Deft 3,254.9 478.1 ...Length/Defi 3,588.1 693.89 Right Cantilever... Camber ( using 1.5 * D.L. DO ) Deflection 0.000 in 0.000 in @ Center 0.119 in ...Length/Deft 0.0 0.0 @ Left 0.072 in @ Right 0.000 in Page 1 5b roof.ecmCalculations Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Dsgnr: Date Description : Building #5, Unit #5B P-56 160 Job # 5500.02 11:35AM, 11 JAN 06 Scope : Hev: oauuua User: KW-0606238, Ver 5.8.0, 1-Dec-2003 General Timber Beam (c)1983-2003 ENERCALC Engineerina Software Description Bm #2 Stress Calcs Bending Analysis Ck 21.584 Le 5.148 ft Sxx 738.281 in3 Area 196.875 in2 Cv 0.879 Rb 4.262 Cl 0.998 Max Moment Sxx Req'd Allowable fb @ Center 58.15 k-ft 331.17 in3 2,107.05 psi @ Left Support 21.02 k-ft 119.76 in3 2,106.22 psi @ Right Support 0.00 k-ft 0.00 in3 2,110.26 psi Shear Analysis @ Left Support @ Right Support Design Shear 15.34 k 15.73 k Area Required 63.911 in2 65.522 in2 Fv: Allowable 240.00 psi 240.00 psi Bearing @ Supports Max. Left Reaction 16.69 k Bearing Length Req'd 2.935 in Max. Right Reaction 10.48 k Bearing Length Req'd 1.843 in Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft -21.02 k-ft 10.23 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 It -21.02 k-ft 10.23 k 0.0000 in Page 2 51c roof.ecw:Calculations Vail Front Door Residences Building #5 Unit #5B L25131-7 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : f,tl V. JOVVV4 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 Page 1 (c)1983.2003ENERCALCEngineering Software Multi-Span Timber Beam 5b roof.ecw:Calculations Description Bm #3 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Douglas Fir, 24F - V8 Fb . Basin Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Spans Considered Continuous Over Support Fv : Basic Allow 240.0 psi Load Duration Factor 1.000 Timber Member Information Description Span ft' 3.50 26.00 8.25 Timber Section 8.75x22.5 8.75x22.5 8.75x22.5 Beam Width in j 8.750 8.750 8.750 Beam Depth in 22.500 22.500 22.500 End Fixity Free - Pin Pin - Pin Pin - Free Le: Unbraced Length ft 3.50 2.00 8.25 Member Type Sawn Sawn Sawn Loads Live Load Used This Span ?Y Yes Yes Yes Dead Load #/ft 220.00 220.00 220.00 Live Load #/ft! 725.00 725.00 725.00 Point #1 Dead Load Ibs 2,300.00 Live Load Ibs, 8,200.00 @ X ft' Results Mmax @ Cntr in-k i 0.0 511.0 0.0 @ X = ft ! 0.00 13.35 0.00 Max @ Left End in k 0.0 -510.5 -385.9 Max @ Right End in-k -510.5 -385.9 0.0 fb : Actual psi, 691.4 692.2 522.7 Fb : Allowable psi 2,228.9 2,233.0 2,214.1 Bending OK Bending OK Bending OK Shear @ Left k 0.00 12.68 7.80 Shear @ Right k 13.81 11.89 0.00 fv :Actual psi 93.4 84.2 45.9 Fv : Allowable Si p 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k 0.00 6.00 4.60 LL @ Left k j 0.00 20.49 15.08 Total @ Left kj 0.00 26.49 19,68 DL @ Right k! 6.00 4.60 0.00 LL @ Right k 20.49 15.08 0.00 Total @ Right k 26.49 19.68 0.00 Max. Deflection in 0.060 -0.302 0.161 @ X = ft 0.00 13.35 8.25 Query Values Location ft 0.00 0.00 0.00 Moment in-k 0.0 -510.5 -385.9 Shear k 0.0 12.7 7.8 Deflection in l 0.0598 0.0000 0.0000 tP_ l0 Title : Vail Front Door Residences Job # 5500.02 Vail Front Door Residences Dsgnr: Date: 11:35AM, 11 JAN 06 Building #5 Description : Building #5, Unit #5B Unit #5B Scope Page 1 Few 580004 User: KW-0606238, ver5.8.0, 1-Dec-2003 Multi-Span Timber Beam 5b roof.ecw:Caiculations (c)1983-2003 ENERCALC Engineering Software y._ Description Bm #4 Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined General Information Douglas Fir, 24F - V8 Fb : Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi i Load Duration Factor 1.000 Spans Considered Continuous Over Support Fv : Basic Allow 240.0 ps Timber Member Information i Description Span f 3.50 20.25 5.50 8.25 Timber Section 8. 75x22.5 8.75x22.5 8.75x22.5 8.75x22.5 Beam Width in 8.750 8.750 8.750 8.750 Beam Depth in 22.500 22.500 22.500 22.500 End Fixity ft Free - Pin 50 3 Pin - Pin Pin - Pin 00 2.00 2 Pin - Free 8.25 Le: Unbraced Length Member Type . Sawn . Sawn Sawn Sawn Loads - Live Load Used This Span ? Dead Load #/ft Live Load #/f Dead Load #/f Live Load #/ft Start ft End ft Dead Load @ Left #/ft Dead Load @ Right #/ft Live Load @ Left #/ft Live Load @ Right #/ft Yes Yes Yes 310.00 310.00 310.00 1,025.00 1,025.00 1,025.00 3.500 20.250 5.500 Start ft~ End ft 3.500 20.250 5.500 Point #1 Dead Load Ibsl 4,900.00 Live Load Ibs 14,100.00 @ X ft; Yes 310.00 1,025.00 4.500 195.00 195.00 650.00 650.00 4.500 8.250 Results X Mmax @ Cnti ink 0.0 272.0 0.0 0.0 @ X = ft 0.00 12.01 0.00 8.25 Max @ Left End in-k1 0.0 -896.1 -263.1 -404.6 Max @ Right End in-k~ -896.1 -263.1 -404.6 0.0 fb : Actual psi j 1,213.8 1,213.8 548.0 548.0 Fb : Allowable psi 2,228.9 2,233.0 2,233.0 2,214.1 Bending OK Bending OK Bending OK Bending OK Shear @ Left k' 0.00 16.12 1.53 9.18 Shear @ Right k 23.67 10.91 5.81 0.00 fv : Actual psi 1 163.7 105.0 24.9 50.9 Fv : Allowable psi1 240.0 240.0 240.0 240.0 Shear OK Shear OK Shear OK Shear OK I Reactions & Deflection - DL @ Left k 0.00 9.85 2.65 3.59 LL @ Left k, 0.00 29.95 9.78 11.40 Total @ Left ki 0.00 39.79 12.44 14.99 DL @ Right k 9.85 2.65 3.59 0.00 LL @ Right k 29.95 9.78 11.40 0.00 Total @ Right k 39.79 12.44 14.99 0.00 Max. Deflection im -0.085 -0.060 0.011 -0.140 @ X = ft i 0.00 12.15 2.86 8.25 Y Values Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Dsgnr: Date Description : Building #5, Unit #5B Scope: Multi-Span Timber Beam 580004 KW-0606238, Ver 5.8.0, 1-Dec-2003 33-2003 ENERCALC Engineering Software Description Bm #4 Job # 5500.02 11:35AM, 11 JAN 06 Page 2 5b roof. ecw:Calculations Location ft 0.00 0.00 0.00 0.00 Moment in-k 0.0 -896.1 -263.1 -404.6 Shear k 0.0 16.1 1.5 9.2 Deflection in -0.0851 0.0000 0.0000 0.0000 95620 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Rev: 580004 Page 1 User: KW-0606238,Ver 5.8.0, 1-Dec-2003 Multi-Span Timber Beam (c)1983.2003 ENERCALC Engineering Software 5b roof. ecw:Calculations Description Bm #5 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Douglas Fir, 24F - V8 Fb : Basic Allow 2,400.0 psi Elastic Modulus 1,700.0 ksi Spans Considered Continuous Over Support Fv : Basic Allow 240.0 psi Load Duration Factor 1.000 Timber Member Information Description Span ft Timber Section Beam Width in Beam Depth in End Fixity Le: Unbraced Length ft Member Type 9.00 5.75 4.00 8.75x22.5 8.75x22.5 8.75x22.5 8.750 8.750 8.750 22.500 22.500 22.500 Pin - Pin Pin - Pin Pin - Free 2.00 2.00 4.00 Sawn Sawn Sawn Loads Live Load Used This Span ? Yes Yes Yes Dead Load #/ft 205.00 330.00 330.00 Live Load #/ft 675.00 1,100.00 1,100.00 Results Mmax @ Cntr in-k 76.4 0.0 0.0 @ X = ft l 3.78 0.00 4.00 Max @ Left End in-k 0.0 -66.1 -137.3 Max @ Right End in-k -66.1 -137.3 0.0 fb : Actual psi 103.5 185.9 185.9 Fb : Allowable psi 2,233.0 2,233.0 2,227.5 Bending,OK Bending OK Bending OK Shear @ Left k 3.35 3.08 5.72 Shear @ Right k 4.57 5.14 0.00 fv : Actual psi 22.0 18.7 23.2 Fv : Allowable psi 240.0 240.0 240.0 Shear OK Shear OK Shear OK Reactions & Deflection DL @ Left k _ 0.78 1.78 2.50 LL @ Left k 2.57 5.87 8.36 Total @ Left k 3.35 7.65 10.86 DL @ Right k; 1.78 2.50 0.00 LL @ Right k'; 5.87 8.36 0.00 Total @ Right k! 7.65 10.86 0.00 Max. Deflection in! -0.006 0.002 -0.013 @ X = ft 4.14 3.37 4.00 Query Values Location m ft 0.00 0.00 0.00 Moment in-k 0.0 -66.1 -137.3 Shear k 3.3 3.1 5.7 Deflection in! 0.0000 0.0000 0.0000 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : r: KW-O6( 983.2003 Description 1-Dec-2003 ineering Software Bm #6 General Information Section Name 8.75x19.5 Beam Width 8.750 in Beam Depth 19.500 in Member Type GluLam Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000 pcf Point Loads Live Load ...distance 6,000.0 Ibs 20,500.0 Ibs 7.250 ft Span= 14.50ft, Beam V\ Max Stress Ratio Maximum Moment Allowable Max. Positive Moment Max. Negative Moment General Timber Beam rage i 5b roof.emCalculations Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Center Span 14.50 ft .....Lu 7.25 ft Left Cantilever ft .....Lu 0.00 ft Right Cantilever ft .....Lu 0.00 ft Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi Fv Allow 240.0 psi Fc Allow 650.0 psi E 1,700.0 ksi Ibs Ibs Ibs IDs iub Ibs Ibs Ibs Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft Beam Design OK 'idth = 8.750in x Depth = 19.5in, Ends are Pin-Pin 0.940 : 1 97.2 k-ft Maximum Shear' 1.5 103.4 k-ft Allowable 97.15 k-ft at 7.250 ft Shear: 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k ft Camber: Max @ Right Support 0.00 k-ft Max. M allow 103.36 Reactions... fb 2,102.37 psi fv 119.13 psi Left DL 3.30 k Fb 2,236.71 psi Fv 240.00 psi Right DL 3.30 k Deflections L ft Cantilever @ Left @ Right @ Left @ Center @ Right Max Max 20.3 k 41.0 k 13.55 k 13.55 k 0.000 in 0.114 in 0.000 i n 13.55 k 13.55 k Center Span... Dead Load Total Load 321 in -0 e Deflection 0.000 in 0.000 in Deflection ...Location -0.076 in 7.250 ft . 7.250 ft ...Length/Deft 0.0 0.0 ...Length/Deft 2,285.6 542.21 Right Cantilever... Camber ( using 1.5 * D.L. Defl ) Deflection in 0.000 0 in 0.0 0 0 @ Center 0.114 in ...Length/Deft .0 0. . . @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.584 Le 14.929 ft Sxx Cv 0.937 Rb 6.756 Cl Max Moment @ Center 97.15 k-ft @ Left Support 0.00 k-ft @ Right Support 0.00 k-ft Shear Analysis @ Left Support Design Shear 20.33 k Area Required 84.692 in2 Fv: Allowable 240.00 psi Bearing @ Supports Max. Left Reaction 13.55 k Max. Right Reaction 13.55 k 554.531 in3 0.995 Sxx Read 521.22 in3 0.00 in3 0.00 in3 @ Right Support 20.33 k 84.692 in2 240.00 psi Bearing Length Req'd Bearing Length Req'd Area 170.625 in2 Allowable fb 2,236.71 psi 2,248.95 psi 2,248.95 psi 2.383 in 2.383 in Vail Front Door Residences Building #5 Unit #56 Rev: 580004 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #6 Roo Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope: General Timber Beam Page 2 5b roof. ecw:Calculations Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 13.55 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Vail Front Door Residences Building #5 Unit #56 k55823 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #513 Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #7 Steel Beam Design Page 1 5b roof. ecw:Calculations Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 a General Information 500ks1 . Steel Section : W10X22 Fixed-Free Load Duration Factor 1.00 Center Span 7.25 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 ksi Left Cant. 0.00 ft LL & S T Act Together Right Cant 0.00 ft Lu : Unbraced Length 7.25 ft Note! Short Term Loads Are WIND Loads. ; Distributed Loads 0; ZZ B" #1 I ME:: #2 43 #4 #5 #6 #7 k/ft DL 0.155 k/ft LL 0.515 k/ft ST ft Start Location ft End Location Summary Beam OK Static Load Case Governs Stress Using: W 10X22 section, Span = 7 .25ft, Fy = 50.Oksi End Fixity = Fixed-Free, Lu = 7.25ft, LDF = 1.000 Actual Allowable Moment 18.188 k-ft 54.277 k-ft Max. Deflection -0.121 in fb : Bending Stress 9.407 ksi 28.074 ksi Length/DL Defl 5,635.6 :1 fb / Flo 0.335 :1 Length/(DL+LL Defl) 1,441.7 :1 Shear 5.017 k 48.816 k fv : Shear Stress 2.056 ksi 20.000 ksi fv / Fv 0.103 : 1 Force A Stress Summary « These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 18.19 k-ft k -ft Max. M - -4.65 -18.19 k ft Max. M @ Left k-ft Max. M @ Right Shear @ Left 5.02 k 1.28 5.02 k k Shear @ Right k Center Defl -0.121 in -0.031 -0.121 -0.121 0.000 0.000 in . Left Cant Defl 0.000in 0.000 0.000 0.000 0.000 0.000 in Right Cant Defl 0.000 in 0.000 0.000 0.000 0.000 0.000 in ...Query Defl @ 0.000 ft 0.000 0,000 0.000 0.000 0.000 in Reaction @ Left 5.02 1.28 5.02 5.02 k-ft k k Reaction @ Fit Fa caldd per Eq. E2-2, K'L/r > Cc I Beam, Major Axis, (102,000' Cb / FV)A.5 L/rT (510,000' CID / FV)A.5 , Fb per Eq. F1-6 1 Beam, Major Axis, Fb per Eq. F1-8, Fb = 12,000 Cb Af / 0 ` d) 959)5 ;LL~ Vail Front Door Residences Building #5 Unit #5B Description Bm #7 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #56 Scope : Section Properties W1OX22 Depth 10.170 in Weight 22.04 #/ft Web Thick 0.240 in Ixx 118.000 in4 Width 5.750 in lyy 11.400 in4 Flange Thick 0.360 in Sxx 23.200 in3 Area 6.49 in2 Syy 3.970 in3 Rt 1.510 in R-xx 4.270 in R_yy 1.330 in Values for LRFD Design.... J 0.240 in4 Zx 26.000 in3 Cw 275.00 in6 Zy 6.100 in3 K 0.660 in K55 `L5 Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Building #5 Description : Building #5, Unit #5B Unit #5B Scope Rev: 580004 Page 1 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 General Timber Beam 5b roof.ecw:Calculations (c)1983-2003 ENERCALC Engineering Software - Description Bm #8 i General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name 8.75x22.5 Beam Width 8.750 in Beam Depth 22.500 in Member Type GluLam Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000 pcf Center Span Left Cantilever Right Cantilever Douglas Fir, 24F - V8 Fb Base Allow Fv Allow Fc Allow E 8.00 ft .....Lu 2.00 ft ft .....Lu 0.00 ft 8.25 ft .....Lu 8.25 ft 2,400.0 psi 240.0 psi 650.0 psi 1.700.0 ksi Full Length Uniform Loads Center DL 115.00 #/ft LL 375.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL #/ft LL #/ft Trapezoidal Loads - - #1 DL @ Left 4 115.00 #/ft LL @ Left 375.00 #/ft Start Loc 8.000 ft 000 ft 10 DL @ Right 115.00 #/ft LL @ Right 375.00 #/ft End Loc . #2 DL @ Left 210.00 #/ft LL @ Left 700.00 #/ft Start Loc 10.000 ft 250 ft 16 DL @ Right 210.00 #/ft LL @ Right 700.00 #/ft End Loc . Juu►n►a► y Span= 8 OOft Right Cant= 8. 25ft, Beam Width = 8.750i n x Depth = 22.5in, Ends are Pin-Pin Max Stress Ratio 0.223 : 1 ' 8 k-ft -31 1. Maximum Shear Maximum Moment . 6 k-ft 143 Allowable Allowable . Max. Positive Moment 1.08 k-ft at 2.000 ft Shear: Max. Negative Moment -8.59 k-ft at 8.000 ft Max @ Left Support 0.00 k-ft Camber: Max @ Right Support -31.76 k-ft Max. M allow 143.63 Reactions... fb 516.18 psi fv 53.54 psi Left DL -0.42 k Fb 2,334.60 psi Fv 240.00 psi Right DL 3.66 k f I t' Beam Design OK 10.5 k 47.3 k @ Left 3.32 k @ Right 7.03 k @ Left 0.000in @ Center 0.005 in @ Right 0.056 in Max -1.82k Max 5 13.18 k De ec ions Center Span... Dead Load Deflection 0.003 in ...Location 4.839 ft ...Length/Deft 29,166.0 Camber ( using 1.5' D.L. Defl ) @ Center 0.005 in @ Left 0.000 in @ Right 0.056 in Total Load Left Cantilever... Dead Load 0.001 in Deflection 0.000 in 6.000 ft ...Length/Deft 0.0 81,613.75 Right Cantilever... Deflection -0.037 in ...Length/Deft 5,301.4 0.000 in 0.0 -0.148 in 1,335.7 1-569v Vail Front Door Residences Building #5 Unit #5B User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #8 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : General Timber Beam Page 2 5b roof.ecw:Calculations Stress Calcs Bending Analysis Cl, 21.584 Le 16.988 ft Sxx Cv 0.980 Rb 7.742 Cl Max Moment @ Center 8.59 k-ft @ Left Support 0.00 k-ft @ Right Support 31.76 k-ft Shear Analysis @ Left Support Design Shear . 4.98 k Area Required 20.739 in2 Fv: Allowable 240.00 psi Bearing @ Supports Max. Left Reaction -1.82 k Max Right Reaction 13.18 k 738.281 in3 0.998 Sxx Read 43.86 in3 0.00 in3 163.23 in3 @ Right Support 10.54 k 43.919 in2 240.00 psi Bearing Length Req'd Bearing Length Req'd Query Values M, V, & D @ Specified Locations Moment @ Center Span Location = 0.00 ft 0.00 k-ft @ Right Cant. Location = 0.00 ff. 0.00 k-ft @ Left Cant. Location = 0.00 ft 0.00 k-ft Area 196.875 in2 Allowable fb 2,348.84 psi 2,352.84 psi 2,334.60 psi 0.320 in 2.318 in Shear -1.82 k -1.82 k 0.00 k Deflection 0.0000 in 0.0000 in 0.0000 in 9562-7 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : mew om u4 User: KW-0606238, Ver5.8.0, 1-Dec-2003 Genera! Timber Beam (0)1983.2003 ENERCALC Engineering Software Description Bm #9 Page 1 5b roof.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Center Span 4.50 ft .....Lu 4.50 ft Beam Width 7.000 in Left Cantilever 8.25ft .....Lu 8.25 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, Microl-am 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0 ksi Full Length Uniform Loads Center DL 55.00 #/ft LL 175.00 #/ft Left Cantilever DL 170.00 #/ft LL 560.00 #/ft Right Cantilever DL #/ft LL #/ft Trapezoidal Loads #1 DL @ Left 115.00 #/ft LL @ Left 375.00 #/ft Start Loc 8.000 ft DL @ Right 115.00 #/ft LL @ Right 375.00 #/ft End Loc 4.500 ft #2 DL @ Left 210.00 #/ft LL @ Left 700.00 #/ft Start Loc 10.000 ft DL @ Right 210.00 #/ft LL @ Right 700.00 #/ft End Loc. 4.500 ft 1 Summary B D i OK -,r eam es gn Span= 4.50ft, Left Cant= 8.25ft, Beam Width = 7.000in x Depth = 11.875in, Ends are Pi n-Pin Max Stress Ratio 0.720 : 1 Maximum Moment Allowable Max. Positive Moment Max. Negative Moment Max @ Left Support . Max @ Right Support Max. M allow fb 1,862.19 psi Fb 2,584.66 psi Deflections -25.5 k-ft Maximum Shear * 1.5 35.4 k-ft Allowable 0.00 k-ft at 4.500 ft Shear: @ Left -6.47 k-ft at 0.000 ft @ Right -25.53 k-ft Camber: @ Left 0.00 k-ft @ Center 35.44 Reactions... @ Right fv 112.54 psi Left DL 3.18 k Max Fv 285.00 psi Right DL -1.27 k Max Center Span... Dead Load Deflection 0.007 in ...Location 1.871 ft Length/Dell 7,232.8 Camber ( using 1.5 * D.L. Defl ) @ Center 0.011 in @ Left 0.261 in @ Right 0.000 in Total Load 0.007 in 1.820 ft 8,147.80 ~v Deflection ...Length/Deft Right Cantilever... Deflection ...Length/Deft 9.4 k 23.7 k 6.24 k 5.50 k 0.261 in 0.011 in 0.000 in 12.43 k -5.11 k -0.174 in -0.697 in 1,137.1 284.0 0.000 in 0.000 in 0.0 0.0 815521 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Rev: 580004 Page 2 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (61983.2003 ENERCALC Enaineerino Software 5b roof.ecw:Calculations Description Bm #9 Stress Calcs Bending Analysis Ck 21.924 Le 16.327 ft Sxx 164.518 in3 Area 83.125 in2 Cf 1.000 Rb 6.892 CI 0.997 Max Moment Sxx Req'd Allowable fb @ Center 6.47 k-ft 29.97 in3 2,591.67 psi @ Left Support 25.53 k-ft 118.53 in3 2,584.66 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 9.35 k 8.26 k Area Required 32.823 in2 28.970 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 12.43 k Bearing Length Req'd 2.367 in Max. Right Reaction -5.11 k Bearing Length Req'd 0.973 in Query Values ~ M, V, & D @ Specified Lo cations Moment Shear Deflection @ Center Span Location = 0.00 ft -25.53 k-ft 6.24 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft -25.53 k-ft 6.24 k 0.0000 in Vail Front Door Residences Building #5 Unit #5B K502~ Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 1 (c)1983-2003 ENERCALC Engineering Software 5b roof ecwCalculations Description Bm #10 General Information Section Name 8.75x22.5 Beam Width 8.750 in Beam Depth 22.500 in Member Type GluLam Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000 pcf Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Center Span 15.75 ft .....Lu 2.00 ft Left Cantilever 8.25 ft .....Lu 8.25 ft Right Cantilever 3.75 ft .....Lu 3.75 ft Douglas Fir, 24F - V8 Fb Base Allow 2,400.0 psi Fv Allow 240.0 psi Fc Allow 650.0 psi E 1,700.0 ksi Full Length Uniform Loads ~MHNIM Center DL 160.00 #/ft LL 525.00 #/ft Left Cantilever DL #/ft LL #/ft Right Cantilever DL 220.00 #/ft LL 735.00 #/ft Trapezoidal Loads #1 DL @ Left 220.00 #/ft LL @ Left 735.00 #/ft Start Loc -8.250 ft DL @ Right 220.00 #/ft LL @ Right 735.00 #/ft End Loc -3750 ft #2 DL @ Left 160.00 #/ft LL @ Left 525.00 #/ft Start Loc -3.750 ft DL @ Right m 160.00 #/ft LL @ Right 525.00 #/ft End Loc 0.000 ft Summary Beam Design OK Span= 15.75ft, Left Can t= 8.25ft, Right Cant= 3.75ft, Beam Width = 8.750in x Depth = 22.5in, Ends are Pi n-Pin Max Stress Ratio 0.244 : 1 Maximum Moment -32.2 k-ft Maximum Shear * 1.5 11.5 k Allowable 134.3 k-ft Allowable 47.3 k Max. Positive Moment 17.56 k-ft at 8.430 ft Shear : @ Left 7 70 k Max. Negative Moment -8.69 k-ft at 0.000 ft @ Right . 5.67 k Max @ Left Support -32.23 k-ft Camber: @ Left 0 053in Max @ Right Support -7.05 k-ft @ Center . 0.004in Max. M allow 134.30 Reactions... @ Right 0.000in fb 523.86 psi fv 58.65 psi Left DL 4.05 k Max 14 96 k Fb 2,182.95 psi Fv 240.00 psi Right DL 2.21 k Max . 9.43 k De flections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection 0.002 in -0.052 in Deflection -0.035 i n -0 221 in ...Location 2.773 ft 8.097 ft ...Length/Defl 5,604.0 . 894 4 ...Length/Deft 77,736.7 3,644.68 Right Cantilever... . Camber (using 1.5 * D.L. Defl) Deflection -0.000 i n -0 043 in @ Center 0.004 in ...Length/Dell 369,263.1 . 2 117 4 @ Left 0.053 in , . @ Right 0.000 in Vail Front Door Residences Building #5 Unit #5B 9569,`9 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Bm #10 rdye G 5b roof.em Calculations ZEMMMMOMMI Stress Caics Bending Analysis Ck 21.584 Le 16.988 ft Sxx 738.281 in3 Cv 0.916 Rb 7.742 Cl 0.998 Max Moment Sxx Read @ Center 17.56 k-ft 96.00 in3 @ Left Support 32.23 k-ft 177.17 in3 @ Right Support 7.05 k-ft 38.60 in3 Shear Analysis @ Left Support @ Right Support Design Shear 11.55 k 8.50 k Area Required 48.112 in2 35.418 in2 Fv: Allowable 240.00 psi 240.00 psi Bearing @ Supports Max. Left Reaction 14.96 k Bearing Length Req'd Max Right Reaction 9.43 k Bearing Length Req'd Area 196.875 in2 Allowable fb 2,195.25 psi 2,182.95 psi 2,192.03 psi 2.630 in 1.658 in Query Values ecified Locations & D @ S V M Moment Shear Deflection p , , @ Center Span Location = 0.00 ft -32.23 k-ft 7.37 k 0.0000 in @ Right Cant. Location = 0.00 ft -32.23 k-ft 7.37 k 0.0000 in 0000 in 0 @ Left Cant. Location = 0.00 ft -32.23 k-ft 7.37 k . General Timber Beam 95&30 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : User: KW-0606238, Ver 5.8.0, (c)1983-2003 ENERCALC Engi Description 1-Dec-2003 General Timber Beam neering Software, Bm #11 Page 1 5b roof.em Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. base allowaDles are user uCIII c~ s Section Name 8.75x22.5 Center Span 19.33 ft .....Lu 2.00 ft 50 ft 4 Beam Width 8.750 in Left Cantilever . 4.50ft .....Lu Lu 3.75 ft 75 ft 3 Beam Depth 22.500 in Right Cantilever . Member Type GluLam Douglas Fir, 24F - V8 Added to Loads Bm Wt Fb Base Allow 2,400.0 psi . Load Dur. Factor 1.000 Fv Allow 240.0 psi Beam End Fixity Pin-Pin Fc Allow 650.0 psi Wood Density 35.000 pcf E 1,700.0 ksi Full Length Uniform Loads Center DL 110.00 #/ft LL 370.00 #/ft Left Cantilever DL 207.00 #/ft LL 688.00 #/ft Right Cantilever DL 207.00 #/ft LL 688.00 #/ft ummary Beam Design UK _ Span= 19.33ft,'Left Cant= 4.50ft, Right Cant= 3.75ft, Beam Width = 8.750in x Depth = 22.5in , Ends are Pin-Pin Max Stress Ratio 0.175 : 1 Maximum Shear" 1.5 8.3 k Maximum Moment 22.5 k-ft 1 k-ft 132 Allowable 47.3 k Allowable . Max. Positive Moment 22.47 k-ft at 9.775 ft Shear: @ Left @ Right 5.50 k 5.31 k Max. Negative Moment -2.58 k-ft at 0.000 ft Max @ Left Support -9.55 k-ft Camber: @ Left @ Center 0.018 in 0.034in Max @ Right Support -6.63 k-ft @ Right 0.017in Max. M allow 132.05 Reactions... fb 365.21 psi fv 4,1.93 psi Left DL 2.71 k Max 9.75 k Fb 2,146.36 psi Fv 240.00 psi Right DL 2.44 k Max 8.85 k Deflections MONOM Center Span... NNEE Dead Load Deflection -0.023 in ...Location 9.775 ft Len gth/ D of I 10, 252.3 Camber ( using 1.5' D.L. Defl ) @ Center 0.034 in @ Left 0.018 in @ Right 0.017 in uldl LudU ~c. v... -0.105 in Deflection 9.665 ft ...Length/Deft 2,210.55 Right Cantilever... Deflection ...Length/Deft 0.012 in 0.071 in 9,116.2 1,514.1 0.012 in 0.061 in 7,777.0 1,465.2 Stress Calcs Bending Analysis Ck 21.584 Le Cv 0.898 Rb @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 9.266 ft Sxx 738.281 in3 Area 196.875 in2 5.718 Cl 0.998 Max Moment Sxx Read Allowable fb 22.47 k-ft 125.36 in3 2,150.82 psi 9.55 k-ft 53.37 in3 2,146.36 psi 6.63 k-ft 37.04 in3 2,147.73 psi @ Left Support @ Right Support 8.25 k 7.97 k 34.393 in2 33.195 in2 240.00 psi 240.00 psi 9.75 k Bearing Length Req'd 1.714 in 8.85 k Bearing Length Req'd 1.555 in P-563) Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Building #5 9 Description : Building #5, Unit #5B Unit #5B Scope Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 2 5b roof.ecw:Calculations (c)1983.2003 ENERCALC Engineering Software r r Description Bm #11 Query Values y M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft -9.55 k-ft 5.25 k 0.0000 in @ Right Cant. Location = 0.00 ft -9.55 k-ft 5.25 k 0.0000 in @ Left Cant. Location = 0.00 ft -9.55 k-ft 5.25 k 0.0000 in Vail Front Door Residences Building #5 Unit #5B p5t$32 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Rev: 580004 User: KW-0606238, (c)1983-2003 ENER Description Ver 5.8.0, 1-Dec-2003 CAC Engineering Software Bm #12 & 12.1 General Timber Beam General Information Code Ref: 1 997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 3. m Center Span 3.67 ft .....Lu 2.00 ft 00 ft 3 Beam Width 3.500 in . Left Cantilever 3.00ft .....Lu 00 ft Lu 0 ft Beam Depth 11.875 in . Right Cantilever Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Added to Loads Bm Wt Fb Base Allow 2,600.0 psi . Factor Load Dur 1.000 Fv Allow 285.0 psi . Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000pcf E 1,900.0ksi Point Loads _ Dead Load 1,000.0 Ibs Ibs Ibs Ibs Ibs Ibs Ib Ibs Ibs Ibs Ibs Live Load 2,600.0 Ibs lbs 000 ft 0 Ibs 000 ft 0 s 0.000 ft 0.000 ft 0.000 ft 0.000 ft ...distance -3.000 ft . . Summary Beam Design OK Span= 3.67f , Left Cant= 3 .00ft, Beam Width = 3.500in x De pth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0 .614 ; 1 Maximum Shear * 1.5 5.4 k Maximum Moment 10.8 k-ft 7 k-ft 17 Allowable 11.8 k Allowable . Max. Positive Moment 0.00 k-ft at 0.00 0 ft Shear: @ Left @ Right 3.63 k 2.94 k Max. Negative Moment -3.05 k-ft at 0.000 ft Max @ Left Support -10.85 k-ft Camber: @ Left @ Center 0.056 in 0.007in Max @ Right Support 0.00 k-ft @ Right O.000in Max. M allow 17.65 Reactions... 582.14 psi fb 1 fv 131.01 psi Left DL 1.88 k Max 6.60k , Fb 2,575.47 psi Fv 285.00 psi Right DL -0.81 k Max -2.94 k Deflections Center Span... Dead Load Total Load Left Cantilever... u Dead Load i 7 otal Load 134 in -0 Deflection 0.005 in 0.005 in 542 ft 1 Deflection Length/Deft n -0.037 1,925.0 . 539.0 ...Location 1.542 ft . ...Length/Deft 9,068.0 9,067.96 Right Cantilever... Camber ( using 1.5 ` D.L. Defl ) Deflection 0.000 in 0.000 in @ Center 0.007 in ...Length/Deft 0.0 0.0 @ Left 0.056 in @ Right 0.000 in Stress Calcs Bending Analysis Ck 21.924 Le Cf 1.000 Rb @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction 6.178 ft 8.479 Max Moment 3.05 k-ft 10.85 k-ft 0.00 k-ft @ Left Support 5.45 k 19.105 in2 285.00 psi 6.60 k -2.94 k Sxx 82.259 in3 Cl 0.994 Sxx Read 14.14 in3 50.53 in3 0.00 in3 @ Right Support 4.40 k 15.456 in2 285.00 psi rage 5b roofiecw: Calculations Area 41.563 in2 Allowable fb 2,584.51 psi 2,575.47 psi 2,600.00 psi Bearing Length Req'd 2.516 in Bearing Length Req'd 1.119 in Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Dsgnr: Date Description : Building #5, Unit #5B Scope : V-5t333 Job # 5500.02 11:35AM, 11 JAN 06 User: KW-0606238, Ver 5.8.0, (c)1983-2003 ENERCALC En( neering Software Bm #12 & 12.1 General Timber Beam Page 2 5b roof. acw:Calculations Description Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft -10.85 k-ft 2.97 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft -10.85k-ft 2.97 k 0.0000 in 95(331-t Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 Building #5 Dsgnr: Date: 11:35AM, 11 JAN 06 Unit #5B Description : Building #5, Unit #5B Scope : Rev: 580004 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam Page 1 (c)1983-2003 ENERCALC Engineering Software 5b roof.ecw:Calculations Description Bm #13 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name Micro Lam: 3.5x11.875 Center Span 19.33 ft .....Lu 2.00 ft Beam Width 3.500 in Left Cantilever 4.50ft .....Lu 4.50 ft Beam Depth 11.875 in Right Cantilever 3.75 ft .....Lu 3.75 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Full Length Uniform Loads Center DL 30.00 #/ft LL 100.00 #/ft Left Cantilever DL 105.00 #/ft LL 335.00 #/ft Right Cantilever DL 105.00 #/ft LL 335.00 #/ft Beam Design OK Span= 19.33ft, Left Cant= 4.50ft, Right Cant= 3.75ft, Beam Width = 3.500in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.317 : 1 Maximum Moment 5.6 k-ft Maximum Shear * 1.5 3.0 k Allowable 17.5 k-ft Allowable 11.8 k Max. Positive Moment 5.56 k-ft at 9.775 ft Shear: @ Left 1.97 k Max. Negative Moment -1.17 k-ft at 0.000 ft @ Right 1.64 k Max @ Left Support -4.56 k-ft Camber: @ Left 0.008 in Max @ Right Support -3.16 k-ft @ Center 0.075in Max. M allow 17.55 Reactions... @ Right 0.024in fb 810.72 psi fv 71.27 psi Left DL 0.92 k Max 3.57 k Fb 2,559.90 psi Fv 285.00 psi Right DL 0.80 k Max 3.15 k Deflections Center Span... Dead Load Total Load Left Cantilever... Dead Load Total Load Deflection -0.050 in -0.388 in Deflection 0.005 in -0.268 in ...Location 9.994 ft 9.665 ft ...Length/Deft 21,556.3 403.4 ...Length/Deft 4,643.3 597.28 Right Cantilever... Camber ( using 1.5 D.L. Defl ) Deflection 0.016 in 0.222 in @ Center 0.075 in ...Length/Deft 5,743.9 406.1 @ Left 0.008 in @ Right 0.024 in Stress Caics Bending Analysis Ck 21.924 Le 9.266 ft Sxx 82.259 in3 Area 41.563 in2 Cf 1.000 Rb 10.384 CI 0.994 Max Moment Sxx Redd Allowable fb @ Center 5.56 k-ft 25.80 in3 2,584.51 psi @ Left Support 4.56 k-ft 21.36 in3 2,559.90 psi @ Right Support 3.16 k-ft 14.79 in3 2,568.01 psi Shear Analysis @ Left Support @ Right Support Design Shear 2.96 k 2.46 k Area Required 10.394 in2 8.614 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 3.57 k Bearing Length Req'd 1.361 in Max. Right Reaction 3.15 k Bearing Length Req'd 1.198 in Vail Front Door Residences Building #5 Unit #5B P15635 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : KW-0606238, Ver 5.8.0, 1-Dec-2003 M-2003 ENERCALC Enaineerina Software Description Bm #13 Query Values M, V, & D @ Specified Locations @ Center Span Location = @ Right Cant. Location = @ Left Cant. Location = General Timber Beam Moment 0.00 ft -4.56 k-ft 0.00 ft -4.56 k-ft 0.00 ft -4.56 k-ft Page 2 5b roof.ecw:Calculations Shear Deflection 1.43 k 0.0000 in 1.43 k 0.0000 in 1.43 k 0.0000 in Ow Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Building #5 Description : Building #5, Unit #5B Unit #5B Scope : Rev: 580004 Page 1 User: KW-0606238, Ver 5.8.0, 1-Dec-2003 General Timber Beam 5b roof.ecw:Calculations (c)1983-2003 ENERCALC Engineering Software Description Bm #14 General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam: 5.25x11.87 Beam Width 5.250 in Beam Depth 11.875 in Member Type Manuf/So.Pine Bm Wt. Added to Loads Load Dur. Factor 1.000 Beam End Fixity Pin-Pin Wood Density 35.000pcf Point Loads Center Span 10.33 ft .....Lu Left Cantilever ft .....Lu Right Cantilever ft ...Lu Truss Joist - MacMillan, MicroLam 1.9 E Fb Base Allow 2,600.0 psi Fv Allow 285.0 psi Fc Allow 750.0 psi E 1,900.0 ksi vcau ~vu.. Live Load 7,300.0 Ibs Ibs Ibs Ibs ...distance 7.000 ft 0.000 ft 0.000 ft 0.000 ft Summary ySpan=~10.33ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin M Stress Ratio 0.809 ; 1 2.00 ft 0.00 ft 0.00 ft Ibs IDs lull Ibs Ibs Ibs 0.000 ft 0.000 ft 0:000 ft CLA Maximum Moment 21.6 k-ft Maximum Shear * 1.5 Allowable 26.7 k-ft Allowable k ft at 6 983 ft Shear: Max. Positive Moment Max. Negative Moment 21.56 - 0.00 k-ft at 10.330 ft Max @ Left Support 0.00 k-ft Max @ Right Support 0.00 k-ft Max. M allow 26.67 Reactions... fb 2,097.02 psi fv 156.77 psi Left DL Fb 2,593.50 psi Fv 285.00 psi Right DL Camber: 0.79 k 1.57 k @ Left @ Right @ Left @ Center @ Right Max Max Beam Design OK 9.8 k 17.8 k 3.14k 6.52 k 0.000 in 0.083 i n 0.000 in 3.14k 6.52 k Deflections Center Span... Dead Load Deflection -0.056 in ...Location 5.620 ft ...Length/Deft 2,230.8 Camber ( using 1.5 * D.L. DO ) @ Center 0.083 in @ Left 0.000 in @ Right 0.000 in Stress Calcs Bending Analysis Total Load Left Cantilever... -0.231 in Deflection 5.620 ft ...Length/Deft 537.13 Right Cantilever... Deflection ...Length/Deft Ck 21.924 Le 4.118 ft Cf 1.000 Rb 4.615 @ Center @ Left Support @ Right Support Shear Analysis Design Shear Area Required Fv: Allowable Bearing @ Supports Max. Left Reaction Max. Right Reaction Max Moment 21.56 k-ft 0.00 k-ft 0.00 k-ft @ Left Support 4.71 k 16.530 in2 285.00 psi 3.14 k 6.52 k Sxx 123.389 in3 Cl 0.997 Sxx Reo'd 99.77 in3 0.00 in3 0.00 in3 @ Right Support 9.77 k 34.294 in2 285.00 psi Bearing Length Req'd Bearing Length Req'd i Load Total Load 0.000 in 0.000 in 0.0 0.0 0.000 in 0.000 in 0.0 0.0 Area 62.344 in2 Allowable fb 2,593.50 psi 2,600.00 psi 2,600.00 psi 0.798 in 1.655 in Vail Front Door Residences Building #5 Unit #5B A~~63-7 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #56 Scope : f User: KW-0606238, Very-8.0, 1-Dec-2003 General Timber Beam Page 2 (c)1"ev:9634003"" ENERCALC Encineerinc Software 5b roof. ecw:Calculations Description Bm #14 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 3.14 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Q Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Vail Front Door Residences Building #5 Unit #5B Steel Beam Design Scope : User: KW-0606238, Ver 5.8.0, 1-Dec-2003 (c)1983-2003 ENERCALC Engineering Software Description Hdr #1 Page 1 5b roof.ecw:Calculations General Information Steel Section : W10X22 Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #513 Code Ref: AISC 9th ASD, 1997 UBC, 2003 IBC, 2003 NFPA 5000 Pinned-Pinned Fy 50.OOksi Load Duration Factor 1.00 Center Span 4.50 ft Bm Wt. Added to Loads Elastic Modulus 29,000.0 kst Left Cant. 0.00 ft LL & ST Act Together Right Cant 0.00 ft Lu : Unbraced Length 4.50 ft Point Loads Note! Short Term Loads Are WIND Loads. #1 #2 #3 #4 #5 46 #7 Dead Load 4.600 k Live Load 15.100 k Short Term k Location 2.250 ft >ummary Beam OK Static Load Case Governs Stress Using: W1 OX22 section, Span = 4.50ft, Fy = 50.Oksi End Fixity = Pinned-Pinned, Lu = 4.50ft, LDF = 1.000 Actual Allowable Moment 22.218 k-ft 63.800 k-ft Max. Deflection -0.019 in fb : Bending Stress 11.492 ksi 33.000 ksi Length/DL Def! 12,082.8: 1 fb J Fb 0.348:1 Length/(DL+LL Defl) 2,850.4: 1 Shear 9.900 k 48.816 k fv : Shear Stress 4.056 ksi 20.000 ksi fv / Fv 0.203 : 1 Force & Stress Summary <<-- These columns are Dead + Live Load placed as noted » DL LL LL+ST LL LL+ST Maximum Only @ Center @ Center @ Cants @ Cants Max. M + 22.22 k-ft 5.23 22.22 k-ft Max. M - k-ft Max. M @ Left k-ft Max. M @ Right k-ft Shear @ Left 9.90 k 2.35 9.90 k Shear @ Right 9.90 k 2.35 9.90 k Center Defl. -0.019 in -0.004 -0.019 Left Cant DO 0.000in 0.000 0.000 Right Cant Def] 0.000 in 0.000 0.000 ...Query DO @ 0.000 ft 0.000 0.000 -0.019 0.000 0.000 0.000 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in 0.000 0.000 in Reaction @ Left 9.90 2.35 9.90 9.90 k Reaction @ Rt 9.90 2.35 9.90 9.90 k Fa calc'd per Eq. E2-1, K'L/r < Cc I Beam Passes Table B5.1, Fb per Eq. F1-1, Fb = 0.66 Fy Section Properties W1OX22 Depth Web Thick Width Flange Thick Area Rt Values for LRFD Design.... J Cw 10.170 in 0.240 in 5.750 in 0.360 in 6.49 in2 1.510 in 0.240 in4 275.00 in6 Weight Ixx lyy Sxx Syy R-xx R-yy Zx Zy K 22.04 #/ft 118.000 in4 11.400 in4 23.200 in3 3.970 in3 4.270 in 1.330 in 26.000 in3 6.100 in3 0.660 in I`<-5731 Vail Front Door Residences Title : Vail Front Door Residences Job # 5500.02 11 JAN 06 Date: 11:35AM , Dsgnr: Building #5 Description : Building #5, Unit #5B Unit #5B Scope Rev: 580004 User: KW-0606238, ver 5.8.0, 1-Dec-2003 Page 1 General Timber Beam 5b roof ecw:Calculations (c)1983-2003 ENERCALC Engineering Software Description Hdr #2 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined de Ref: 1997/2001 NDS C General Information , o Section Name MicroLam: 5.25x11.87 Center Span 3.25 ft .....Lu 1.75 ft Lu 0.00 ft ft Beam Width 5.250 in Left Cantilever Lu 0.00 ft ft Beam Depth 11.875 in Right Cantilever Truss Joist - MacMilla MicroLam 1.9 E n Member Type Added to Loads Bm Wt Manuf/So.Pine , Fb Base Allow 2,600.0 psi . Load Dur. Factor 1.000 Fv Allow 285.0 psi 0 psi 750 Beam End Fixity Pin-Pin Fc Allow E . 900.0 ksi 1 Wood Density 35.000 pcf , Live Loady 12,800.0 Ibs Ibs Ibs Ibs ...distance 1.750 ft 0.000 ft 0.000 ft 0.000 ft Summary Span= 3.25ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin Pin M Q+' ss Ratio 0.761 : 1 Ibs Ibs Ibs 0.000 ft 0.000 ft 0.000 ft Beam Design OK ax e Maximum Moment 13.5 k-ft Maximum Shear * 1.5 Allowable 26.7 k-ft Allowable k ft t 1 755 ft Shear: Max. Positive Moment Max. Negative Moment 13.46 - a 0.00 k-ft at 0.000 ft Max @ Left Support 0.00 k-ft Max @ Right Support 0.00 k-ft Max. M allow 26.68 Reactions... fb 1,309.36 psi fv 216.95 psi Left DL Fb 2,594.34 psi Fv 285.00 psi Right DL Camber: 1.82 k 2.12 k @ Left @ Right @ Left @ Center @ Right Max Max 13.5 k 17.8 k 7.73 k 9.02 k 0.000 in 0.005 in 0.000 in 7.73 k 9.02 k L Deflections Center Span... Dead Load Total Load Deflection -0.003 in -0.015 in ...Location 1.664 ft 1.664 ft ...Length/Deft 11,263.3 2,646.34 Camber ( using 1.5 * D.L. Defl ) @ Center 0.005 in @ Left 0.000 in @ Right 0.000 in Left Cantilever... Dead Load Total Load Deflection 0.000 in 0.000 in ...Length/Deft 0.0 0.0 Right Cantilever... Deflection 0.000 in 0.000 in ...Length/Deft 0.0 0.0 Stress Calcs z Bending Analysis Ck 21.924 Le 3.604 ft Sxx 123.389 in3 Area 62.344 1n2 Cf 1.000 Rb 4.317 Max Moment Cl 0.998 Sxx Redd Allowable fb @ Center 13.46 k-ft 62.27 in3 2,594.34 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi @ Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 11.60 k 13.53 k Area Required 40.696 in2 47.458 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports 73 k 7 Bearing Length Req'd 1.964 in Max. Left Reaction Max. Right Reaction . 9.02 k Bearing Length Req'd 2.290 in P-JI Ltv Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : Hew 560004 Page 2 56 User: KW-0606238, Ver5.8.0, 1-Dec-2003 General Timber Beam (c179A3-9003 FNFRCALC Fnninaarinn Snftware 5b roof.emCalculations Description Hdr #2 Query Values M, V, & D @ Specified Locations Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k.-ft 7.73 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in Nt,V15''$1 Vail Front Door Residences Building #5 Unit #5B Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : General Timber Beam Description Hdr #3 Page 1 5b roof.ecw:Calculations General Information Code Ref: 1997/2001 NDS, 2000/2003 IBC, 2003 NFPA 5000. Base allowables are user defined Section Name MicroLam:5.25x11.87 -,._r_. - Center Span 3.50 ft .....Lu 3.50 ft Beam Width 5.250 in Left Cantilever ft .....Lu 0.00 ft Beam Depth 11.875 in Right Cantilever ft .....Lu 0.00 ft Member Type Manuf/So.Pine Truss Joist - MacMillan, MicroLam 1.9 E Bm Wt. Added to Loads Fb Base Allow 2,600.0 psi Load Dur. Factor 1.000 Fv Allow 285.0 psi Beam End Fixity Pin-Pin Fc Allow 750.0 psi Wood Density 35.000 pcf E 1,900.0 ksi Point Loads Dead Load 4,000.0 Ibs Ibs Ibs Ibs Ibs Ibs los Live Load 11,000.0 lbs Ibs Ibs Ibs Ibs Ibs Ibs ...distance 1.750 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft 0.000 ft Summary Beam Design OK Span= 3.50ft, Beam Width = 5.250in x Depth = 11.875in, Ends are Pin-Pin Max Stress Ratio 0.635 : 1 Maximum Moment 13.1 k-ft Maximum Shear 1.5 11.3 k Allowable 26.6 k-ft Allowable 17.8 k Max. Positive Moment 13.15 k-ft at 1.750 ft _ Shear: @ Left 7.53 k Max. Negative Moment 0.00 k-ft at 0.000 ft @ Right 7.53 k Max @ Left Support 0.00 k-ft Camber: @ Left 0.000 in Max @ Right Support 0.00 k-ft @ Center 0.007in @ Right 0.000in Max. M allow 26.61 Reactions... fb 1,278.71 psi fv 181.09 psi Left DL 2.03 k Max 7.53 k Fb 2,588.23 psi Fv 285.00 psi Right DL 2.03 k Max 7.53 k Deflections Center Span... Dead Load Total Load Left Cantilever.,. Dead Load Total Load Deflection -0.004 in -0.017 in Deflection 0.000 in 0.000 in ...Location 1.750 ft 1.750 ft ...Length/Deft 0.0 0.0 ...Length/Deft 9,391.6 2,519.60 Right Cantilever... Camber ( using 1.5 * D.L. DO Deflection 0.000 in 0.000 in @ Center 0.007 in ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in Stress Calcs ~ Bending Analysis Ck 21.924 Le 7.207 ft Sxx 123.389 in3 Area 62.344 in2 Cf 1.000 Rb 6.105 Cl 0.995 Max Moment Sxx Req'd Allowable fb @ Center 13.15 k-ft 60.96 in3 2,588.23 psi @ Left Support 0.00 k-ft 0.00 in3 2,600.00 psi Q Right Support 0.00 k-ft 0.00 in3 2,600.00 psi Shear Analysis @ Left Support @ Right Support Design Shear 11.29 k 11.29 k Area Required 39.613 in2 39.613 in2 Fv: Allowable 285.00 psi 285.00 psi Bearing @ Supports Max. Left Reaction 7.53 k Bearing Length Req'd 1.911 in Max. Right Reaction 7.53 k Bearing Length Req'd 1.911 in Vail Front Door Residences Building #5 Unit #5B User: KW-0606238, Ver5.8.0, 1-Dec-200: (c)1983-2003 ENERCALC Engineering Sc Description Hdr #3 III--l"PO 7~ Title : Vail Front Door Residences Job # 5500.02 Dsgnr: Date: 11:35AM, 11 JAN 06 Description : Building #5, Unit #5B Scope : General Timber Beam Page 2 5b roof. ecw:Calculations uuery values - M, V, & D @ Specified Locations . n. _ Moment Shear Deflection @ Center Span Location = 0.00 ft 0.00 k-ft 7.53 k 0.0000 in @ Right Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in @ Left Cant. Location = 0.00 ft 0.00 k-ft 0.00 k 0.0000 in The Chalets at the Lodge at Vail Building E (M & N #5500.02) Building #6 Calculations See Building #2 for Calculations of Building #6