Loading...
HomeMy WebLinkAboutB06-0028 Permit �� Community Development Department 75 South Frontage Road Vail, Colorado USA 81657 CERTIFICATE OF OCCUPANCY This certificate is issued pursuant to the requirements of Title 10, Section 10-1-2, ADOPTED CODES of the Vail Town Code certifying that, at the time of issuance, this structure was found to be substantially in compliance with the various ordinances of the town regulating building construction or use for the following: Name and description of project Vail's Front Door Buildin�E Buildin�5 units 9,10,11 Address of project: 174 Gore Creek Drive Vail CO 81657 Owner name and address: Lodge Properties Inc 174 Gore Creek Dr Vail,Co IBC Edition: 2003 IBC Occupancy Group(s): R2 Type(s) of Construction: VB Permit Number(s): B06-0028 Occupant Load: Sprinkler System Y/N Type: Y 13 Martin Haeberle,Chief Building Official 2 � Date TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW(SFR,P/S,DUP) PERMIT Permit #: B06-0028 ��Z��v `��� Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VaILS FRONT DOOR BUILDING'E' iJNIT 5 Applied . . : 02/13/2006 Parcel No...: 210108278002 Issued . . . 06/26/2008 Legal Description: Expires.....: 11/14/2008 Project No : PRJ06-0038 OWNER LODGE PROPERTIES INC 02/13/2006 PO BOX 7 VAIL CO 81658 ARCHITECT 4240 ARCHITECTURE, INC. 02/13/2006 Phone: 303-292-3388 1621 18TH STREET SUITE 200 DENVER CO 80202 License: C000001868 APPLICANT HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A CONTRACTOR HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A Desciption: VAILS FRONT DOOR BUILDING 'E' LJNIT 5 CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Occupancy Type Factor Sq Feet Valuation RESIDENTIAL/MULTFAM( ZONE 3 VB 116 . 28 14, 557 $1, 692, 687 . 96 STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 345 $39, 737 . 10 Totals . . . 14, 557 53 , 714, 875 . 00* Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 3,714,875.00 Fireplace Information: Restricted:Y #of Gas Appliances: 0 �of Gas Logs: 0 #of Wood Pallet: 0 r***►+**s***�***r****s*��a*►***►****�������++***�*rr*��*�**r*x�**+*+* FEE S UMMARY+.+��•*s****r*+*�**+***r��+***.*•.•�*•�v*s++.s*�*****+*.++s Building------> $15,518.50 Restuarant Plan Review--> $0.00 Total Calculated Fees-----> $35,798.42 Plan Check---> $l0,087.02 Recreation Fee------------> $l0,189.90 Additional Fees------------> ($690.00) lnvestigation-> $0.0 0 TOTAL FEES-------------> $3 5,7 9 8.4 2 Total Permit Fee-----------> $3 5,10 8.4 2 W ill Call-----> $3.o o Payments-------------------> $3 5,10 8.4 2 BALANCE DUE---------> $0.00 ****�a�*r*+*+*******�*s**r*r*�******��+�r***r**�*r*********s*►*►***:r**«**►**�+***s*s**a*���***r******sr**►�*sa*�**a�*�*�+�*es.*�*s*�*a***+*►e�++ Approvals: Item: 05100 BUILDING DEPARTMENT 07/19/2006 cdavis Action: AP 12/05/2006 jplano Action: AP Approved Rev 1 root moditications tor insu. hours 07/09/2007 ep Action: DN Rev2 . IR4701 . No additional valuation. 10/04/2007 ependley Action: AP Rev4/IR5637 . Approved ASI E-056 Unit 11 Bu� No added valuation. Added plan review fee of �120 . 00 due . 12/19/2007 jplano Action: AP Rev3/IR5633/ASI E-054, unit 5 buyer change: $180 due 04/23/2008 jplano Action: DN Rev6 . IR7178/ASI E-054a, buyer changes, Neec window from the new bedroom XX19 05/08/2008 sgremmer Action: AP REF 7559 REV 7 ASI E-055a unit 10 buyer ch< 05/22/2008 NSC Action: AP Approved B06-0028 REV. 8 IR#7654 ASI# E-056i before issue of permit . 11/11/2008 NSC Action: AP Approved B06-0028 REV#6 ASI E-054A Unit #9 changes . IR#7178 $180 . 00 due for plan check fee. Item: 05400 PLANNING DEPARTMENT 07/19/2006 George Action: AP 11/O1/2007 GR Action: AP UNIT #11-ASI E-056 04/02/2008 George Action: PA This is a partial approval tor interior ch� Unit #9 ASI E54 dated March 27, 2008 Item: 05600 FIRE DEPARTMENT 07/18/2006 McGee Action: AP 11/O1/2007 mcgee Action: DN ASI E-054 Unit 9 5A Plans showing changes to fire alarm and fire sprinkler are not stamped by BCER. 11/O1/2007 mcgee Action: DN ASI Unit 11 5C Sheets A 152, 154, 156 show changes to tire alarm and tire sprinkler but plans arE stamped by BCER. Ol/09/2008 JJR Action: DN ASI -055 UNIT 10 Changes to fire sprinkler and fire alarm not stamped by BCER. 02/13/2008 mcgee Action: AP ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP B06-0028 ASI E 054 Unit 9 (5A) Rev 3 02/13/2008 mcgee Action: AP B06-0028 ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP ASI E 054 Unit 9 (5a) Rev 3 05/28/2008 JJR Action: AP ASI E-055a Unit 10 (5B) Also noted in permit REV08-0006 08/05/2008 McGee Action: AP ASI E-054a 08/05/2008 McGee Action: AP ASI E-056a Item: 05500 PUBLIC WORKS 07/14/2006 tk Action: AP Approved Building permit revisions dated rf 6/16/06 and 7/06/06 Item: 05550 ENGINEERING CIVILS +.*.+.«*..*.*.:*..**.*.*�+*s*+*��+*+***�*.*.�«�:**.�**+**+�+�.�►***�**.:*..*.*.****:s*.�.*�.**r**.*.�+�.�*�**.+�.*.***�*****...**�+***�.*�*+.+�.* See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ardinances and state laws, and to build this structure accarding to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town a e thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVA E TELEPHONE T 479-2149 OR A OUR OFFICE FROM 8:00 AM-4 PM. f SI URE OF OWNER OR RACTOR FOR HIMSELF AND OWNER �f PAGE 2 ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B06-0028 as of 11-19-2008 Status: ISSUED ******************************************************************************************************** Permit Type: NEW(SFR,P/S,DUP)PERMIT Applied: 02/13/2006 Applicant: HYDER CONSTRUCTION, INC Issued: 06/26/2008 Job Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E'L1NIT 5 Parcel No: 210108278002 ******************************************************************************************************** � CONDITIONS ******************************************************************************************************** Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PR10R TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ************��********************************************************�********************* TOWN OF VAIL, COLORADO Statement ****++***************�***********+***************************************************+****** Statement Number: R080002229 Amount: $180.00 11/19/200804 :06 PM Payment Method: Check Init: DDG Notation: Hyder 61427 ----------------------------------------------------------------------------- Permit No: B06-0028 Type: NEW (SFR, P/S,DUP) PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $35, 108.42 This Payment: $180.00 Total ALL Pmts: $35, 108.42 Balance: $0. 00 *****************+*********************************************************+**************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300, PLAN CK - project GFP012 180.00 ----------------------------------------------------------------------------- ,. ��`. �� �,� � �l,�l�#►�,� / ' - �,,";'�z+'��,�e _ �� j� Buiiding artment S�rvic ` 'S.til:X 4 h...�,F �rx;,.: +4�: � *,, November 1l, 2008 y „��. ,�` ,�°'�� � Martin Haeberle ��"�'���� °��, ��'� �;�,, �:� Chief Building Official, Town of Vail ���� �,�.:�� 75 South Frontage Road Vail, CO 81657 RE: PROJECT: ° ;�b►SI E-054a Unit#9 Buyer Revisions PERMIT NUMBER: B06-0028 REVISION NUMBER: REV6 INTERNAL REF#: 7654 ADDRESS: 151 Vail Lane Dear Mr. Ruther: SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003 International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the documents submitted to be complete for construction. Plans: ASI instructions/ 10 sheets , � � � ,� No additional square footage- No added valuation Sincerel , John Plano Plans Examiner/Senior Building Inspector SAFEbuilt Colorado John.plano(n�SAFEbuilt.com Page 1 of 1 SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631 Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax: (970)328-1791✓V:�Plan Review\Vail�Front Door�B06-0028\tov-b06- 0028_IR#7178_FAL.doc 3� 1�- o� ��,� �� 0 � C� � � �`r� ` �I �G:: A ICATION WILL NOT BEI� EPTED IF INCOMPLETE OR UNSIGNED �' ��r Building Permit# 'P� iQQ Cx�B �r �j J I" 97t�-d°T���2���9�`n(�nspect�ons) � u , ������L � �� I��I ��YTOWN OF VAIL BUILDING PERMIT � e�rmft� �re required for electr�cal, plumbmg, mechanical, etc.. 75 S. Frontage Rd. Vail, Colorado 81657 , � ***All Revision submittals must include the Field Set of approved plans. No further inspections will be performed until the revisions are approved. *** CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact and Phone#'s: L' -A Z �,. �-� v � �� �I AT ENTION: ,JR,CHARLIE,GREG,CHRIS Contrac Signature: COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ For Parcel# Contact Ea le Count Assessors Office af 970-328-8640 or visit www.ea le-count .com P�rcei;�# d�O�o 1 Job Name: �\�s �' Job Address: S� ,` N� Legal Description Lot: Block: Filing: Subdivision: Owners Name: a .�a �1�-s Address: _ Phone: ArchitecUDesigner: 4a � Address: Phone: � Engineer: M� Q Q � Address: Phone: REASON FOR REVISIONS: /�.5-�- E- O�q�, - C��-�'�'i�Sh.� gv.��, ��.�g� C?.,: ti uv� Work Class: New�Q Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( ) Work Type: Interior( ) Exterior( ) Both (� Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No ( ) **�*�**********�****************,�*,�**************FOR OFFICE USE ONLY******�*,�**,�*****�*��*�*******,�*********�***** Date Received:. Permit Fee 10 : Plan Ck Fee '80 : Accepted By: � : . "�� ��: P�"rmit Fee�(11): �� '�� � :Plan:Gk Fee.�81) F ; . •. Outsourced Terms: '° F:lcdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 4/18/2007 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW(SFR,P/S,DUP) PERMIT Permit #: B06-0028 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING'E' LJNIT 5 Applied . . : 02/13/2006 Parcel No...: 210108278002 Issued . . . 06/26/2008 Legal Description: Expires.....: O1/17/2007 Project No : PRJ06-0038 OWNER LODGE PROPERTIES INC 02/13/2006 PO BOX 7 VAIL CO 81658 ARCHITECT 4240 ARCHITECTURE, INC. 02/13/2006 Phone: 303-292-3388 1621 18TH STREET SUITE 200 DENVER CO 80202 License: C000001868 APPLICANT HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License : 109-A CONTRACTOR HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A Desciption: VAILS FRONT DOOR BUILDING'E' UNIT 5 CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Occupancy Type Factor Sq Feet Valuation RESIDENTIAL/MULTFAM( ZONE 3 VB 116 . 28 14, 557 $1, 692, 687 . 96 STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 345 $39, 737 . 10 Totals . . . 14, 557 $3 , 714, 875 . 00* Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 3,714,875.00 Fireplace Information: Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pallet: 0 *+***�***�**r�+�+*rr*rr**+��***�*�*�***r**�*�**�*+**�***r*►**�+�****■ FEE SUMMARY*•**.a.�.r****.**►*��+*+�*���+�,.****.►*�*.*•*..��+�*�.*+�� Building------> $15,518.5 0 Restuarant Plan Review--> $o.o o Total Calculated Fees-----> $3 5,7 9 8.4 2 Plan Check---> $i o,o a�.0 2 Recreation Fee------------> $10,18 9.9 0 Additional Fees------------> ($6�o.o o) Investigation-> $o.00 TOTAL FEES-------------> $35,798.42 Total Permit Fee-----------> $34,928.42 W ill CaII-----> $3.0 0 Payments-------------------> $3 4,9 2 8.4 2 BALANCE DUE---------> $0.00 ****r****r►*r*+�**�+.*�*�*r*+*r��*****ss***r*sr■*�r+��+�t*rrr.�*�*+**rs*�*�*t*tr**r*r+a*****r*+*sr****a*******�*+*rr+r*�+r*a**+�*a**v**�►«a*:r.s* Approvals: Item: 05100 BUILDING DEPARTMENT 07/19/2006 cdavis Action: AP 12/05/2006 jplano Action: AP Approved Rev 1 root moditications tor insu. hours 07/09/2007 ep Action: DN Rev2 . IR4701 . No additional valuation. 10/04/2007 ependley Action: AP Rev4/IR5637 . Approved ASI E-056 Unit 11 Bu, No added valuation. Added plan review fee of $120 . 00 due. 12/19/2007 jplano Action: AP Rev3/IR5633/ASI E-054, unit 5 buyer change; $180 due 04/23/2008 jplano Action: DN Rev6 . IR7178/ASI E-054a, buyer changes, Neec window from the new bedroom XX19 05/08/2008 sgremmer Action: AP REF 7559 REV 7 ASI E-055a unit 10 buyer ch< 05/22/2008 NSC Action: AP Approved B06-0028 REV. 8 IR#7654 ASI# E-056� before issue of permit . Item: 05400 PLANNING DEPARTMENT 07/19/2006 George Action: AP 11/Ol/2007 GR Action: AP UNIT #11-ASI E-056 04/02/2008 George Action: PA This is a partial approval tor interior ch< Unit #9 ASI E54 dated March 27, 2008 Item: 05600 FIRE DEPARTMENT 07/18/2006 McGee Action: AP 11/Ol/2007 mcgee Action: DN ASI E-054 Unit 9 5A Plans showing changes to fire alarm and fire sprinkler are not stamped by BCER. 11/O1/2007 mcgee Action: DN ASI Unit 11 5C Sheets A 152, 154, 156 show changes to tire alarm and tire sprinkler but plans arf stamped by BCER. Ol/09/2008 JJR Action: DN ASI -055 UNIT 10 Changes to fire sprinkler and fire alarm not stamped by BCER. 02/13/2008 mcgee Action: AP ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP B06-0028 ASI E 054 Unit 9 (5A) Rev 3 02/13/2008 mcgee Action: AP B06-0028 ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP ASI E 054 Unit 9 (5a) Rev 3 05/28/2008 JJR Action: AP ASI E-055a Unit 10 (5B) Also noted in permit REV08-0006 Item: 05500 PUBLIC WORKS 07/14/2006 tk Action: AP Approved Building permit revisions dated rE 6/16/06 and 7/06/06 Item: 05550 ENGINEERING CIVILS .�*+...**��*.�*+*��*.*«+..*��...****+�+�**.*..�*«.***.»*..+*.+*.�**.�.*.*.*.**...�.»��»*.*►�*�.*.,*��*++*.*+�+�*«...*.++*�.*,*.«*�.*.,.*�*�.�*+** See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BF.MADE TWENTY-FOUR HOURS[N ADVANCE BY TE�EPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. ---.,� ,, �r_ SIGNATURE OF OW O TRACTO RT�4S�LF AND OWNER _..._� PAGE 2 ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B06-0028 as of 06-26-2008 Status: ISSUED ******************************************************************************************************** Permit Type: NEW(SFR,P/S,DUP)PERMIT Applied: 02/13/2006 Applicant: HYDER CONSTRUCTION, INC Issued: 06/26/2008 Job Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Parcel No: 210108278002 ******************************************************************************************************** CONDITIONS ******************************************************************************************************** Cond: 33 (PLAN)THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. l ����� ` Hyder Constructdon June 11th, 2008 Permits/revisions ready for pick up. Doug Thompson has been contacted. These are the fees due: Fee Item# B06-0022 Revision 15, ASI E-077 $ 60.00 81 B06-0018 Revision 20, ASI 0-028 $ 120.00 81 B06-0028 Revision 8, ASI E-056A $ 120.00 81 B06-0021 Revision N/A, Ref#7436 $ 120.00 81 ,, . . ..� ..x...� .,r,. . . .. �. ..r., ra ,��� „��2�,� T���������������� � .d�- Y '�. 3�' f �a.� TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW(SFR,P/S,DUP) PERMIT Permit #: B06-0028 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING 'E' 11NIT 5 Applied . . : 02/13/2006 Parcel No...: 210108278002 Issued . . . 06/26/2008 Legal Description: Expires.....: O1/17/2007 Project No : PRJ06-0038 OWNER LODGE PROPERTIES INC 02/13/2006 PO BOX 7 VAIL CO 81658 ARCHITECT 4240 ARCHITECTURE, INC. 02/13/2006 Phone : 303-292-3388 1621 18TH STREET SUITE 200 DENVER CO 80202 License: C000001868 APPLICANT HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A CONTRACTOR HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License : 109-A Desciption: VAILS FRONT DOOR BUILDING'E'LJNIT 5 CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Occupancy Type Factor Sq Feet Valuation RESIDENTIAL/MULTFAM( ZONE 3 VB 116 .28 14, 557 $1, 692, 687 . 96 STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 345 $39, 737 . 10 Totals . . . 14, 557 $3, 714, 875 . 00* Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 3,714,875.00 Fireplace Information: Restricted:Y #of Gas Appliances: 0 #of Gas l.ogs: 0 #of' Wood Pallet: 0 ��***r**r�s�r******a**��r****�r**r****�***+*��**r*+**+*r****+*a**r*�* FEE SUMMARY*�+�«�****+r**�*r�*�*******+r**+*+*�*+*+***�r+***r*+�****** Building------> $15,518.5 0 Restuarant Plan Review--> $o.o o Total Calculated Fees-----> $3 5,7 98.4 2 Plan Check---> $10,0 6 7.0 2 Recreation Fee------------> $10,1 B 9.9 o Additional Fees------------> ($9 9 0.0 0) lnvestigation-> $o.0 0 TOTAL FEES-------------> $3 5,7 9 6.4 2 Total Perm it Fee-----------> $3 4,8 0 8.4 2 W ill Call-----> $3.0 0 Payments-------------------> $3 4,8 0 6.4 2 BALANCE DUE---------> $0.00 •�**�s***�**�****+�*��***+�+*r*err+*r�*+*+*****+*+*�*�****«r+*�*�***��«�*rr*r**t*�****a*+**���a**+��a*****��*��*a***�*+r+�*r+�ar+.�r++x**�srr***� Approvals: Item: 05100 BUILDING DEPARTMENT 07/19/2006 cdavis Action: AP 12/05/2006 jplano Action: AP Approved Rev 1 root moditications tor insu. hours 07/09/2007 ep Action: DN Rev2 . IR4701 . No additional valuation. 10/04/2007 ependley Action: AP Rev4/IR5637 . Approved ASI E-056 Unit 11 Bu� No added valuation. Added plan review fee of $120 . 00 due. 12/19/2007 jplano Action: AP Rev3/IR5633/ASI E-054, unit 5 buyer change: $180 due 04/23/2008 jplano Action: DN Rev6 . IR7178/ASI E-054a, buyer changes, Neec window from the new bedroom XX19 05/08/2008 sgremmer Action: AP REF �559 REV 7 ASI E-055a unit 10 buyer ch< 05/22/2008 NSC Action: AP Approved B06-0028 REV. B IR#7654 ASI# E-056i before issue of permit . Item: 05400 PLANNING DEPARTMENT 07/19/2006 George Action: AP 11/O1/2007 GR Action: AP UNIT #11-ASI E-056 04/02/2008 George Action: PA This is a partial approval tor interior ch� Unit #9 ASI E54 dated March 27, 2008 Item: 05600 FIRE DEPARTMENT 07/18/2006 McGee Action: AP 11/Ol/2007 mcgee Action: DN ASI E-054 Unit 9 5A Plans showing changes to fire alarm and fire sprinkler are not stamped by BCER. 11/Ol/2007 mcgee Action: DN ASI Unit 11 5C Sheets A 152, 154, 156 show changes to tire alarm and tire sprinkler but plans arE stamped by BCER. O1/09/2008 JJR Action: DN ASI -055 UNIT 10 Changes to fire sprinkler and fire alarm not stamped by BCER. 02/13/2008 mcgee Action: AP ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP B06-0028 ASI E 054 Unit 9 (5A) Rev 3 02/13/2008 mcgee Action: AP B06-0028 ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP ASI E 054 Unit 9 (5a) Rev 3 05/28/2008 JJR Action: AP ASI E-055a Unit 10 (5B) Also noted in permit REV08-0006 Item: 05500 PUBLIC WORKS 07/14/2006 tk Action: AP Approved Building permit revisions dated rE 6/16/06 and 7/06/06 Item: 05550 ENGINEERING CIVILS �..+**+.*+.*,«*.*«►***�.***.*.*.**�***+**�**.*.*..*►*►�.*.**...:...*.....*.*...:+*+:.:..,.*+.*...*.�**.**++..*....*,*.+*.�.*►*+.*.�.*+**.*.*.*�.. See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. PAGE 2 ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B06-0028 as of 06-26-2008 Status: ISSUED ******************************************************************************************************** Permit Type: NEW(SFR,P/S,DUP)PERMIT Applied: 02/13/2006 Applicant: HYDER CONSTRUCTION, INC Issued: 06/26/2008 Job Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E'LJNIT 5 Parcel No: 210108278002 ******************************************************************************************************** CONDITIONS ******************************************************************************************************** Cond: 33 (PLAN)THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. �'- �-. `''��'`�. `^_� /, � SIGNATURE OF OWNER O �` N�' CTOR F - �AND OWNER *******************************************************************************���******�*** TOWN OF VAIL, COLORADO Statement ***********************�************�*+*********�+******************+****************�****** Statement Number: R080001037 Amount: $210. 00 06/26/200810:23 AM Payment Method: Check Init: DDG Notation: Hyder 60207 ----------------------------------------------------------------------------- Permit No: B06-0028 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $34, 808 .42 This Payment: $210.00 Total ALL Pmts: $34, 808 .42 Balance: $0.00 *******************************************************�*�********************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300, PLAN CK - project GFP012 210. 00 ----------------------------------------------------------------------------- . ����� � H der Construction Y June 20t", 2008 Permits/revisions ready for pick up. Doug Thompson has been contacted. These are the fees due: Fee Item# B06-0028 Revision 7, ASI E-055a $ 210.00 81 T��`�..,.F�E� I?UE Tt'�C�/�tY„ , , , . , = ',���}r�t� �,a� � o� , o� � o�a � . � . � APPUCATION WILL T BE A CEPTED IF INCOMPLE OR UNSIGNED � ��L� (Q --(yjC>��� �������� � � ��'��� Building Perm►t# � $ � `,\ij �r -�� �� �;��,�� 97"�-4!'9'21���Itis„ �i�.��.,. ��-': � : '' �_. . . �_ . . ... .. _. r . �` � "; . , ������ f REVISIO _ O TOWN O�� 4 L � UILDING PERMIT Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. �.,e Vail, Colorado 81657 ��°���� �� ,�,. �,, ***All Revision submittals must include the Field Set of approved plans. No ftxrl:h�r-rr�s� e will be perFormed until the revisions are approved. *** ��\ CONTRACTOR INFORMATION \� General Contractor: Town of Vail Reg. No.: Contact and Phone#'s: � �e r �} � — � c� '1 "1 - ATT NTION: OE JR,CHARLIE,GREG,CHRIS Contractor Signature: COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $ , � PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ � � � For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com Parcei�# �� a,\o���a �o`� � Job Address: � Job Name: vG N``S � � r \S� Va: � �..G�n e i� \�'l Legal Description Lot: Block: Filing: Subdivision: � Owners Name: RQ Address: . Phone: � Architect/Designer: Address: Phone: O Engineer: � � �" Address: Phone: REASON FOR REVISIONS: - AST E-o a (.J�r•�k�`\O '&�•.�e� e�e.r:5:o�s Work Class: New(p,� Addition ( ) Remodel ( ) Ftepair( ) Demo( ) Other( ) Work Type: Interior( ) Exterior( ) Both (p� Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s� Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No( ) **�*�****�*�*************************************FOR OFFICE USE ONLY********��*�*�*�*�*�********�****��*�********* Date Recei�ed:! Permit Fee 10 : ` PIan.Ck Fee`80 :: Accepted By: ,' . .� � '�� � Permit Fee��.(11): ��� � PIan�CkFee�81) ,���; � O'utsourced Terms: y F:\cdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 4/18/2007 � � ' � � ������nc. c.t�t.c���Do Bu�ldittg D�partmeat 5enrices May 8, 2008 George Ruther Community Development, Town of Vail 75 South Frontage Road Vail, CO 81657 RE: PROJECT: Front Door ASI E-055a unit#10 buyer changes PERMIT NUMBER: B06-0028 REVISION NUMBER: REV7 INTERNAL REF#: 7559 ADDRESS: 151 Vail Lane Dear Mr. Ruther: SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003 tnternational Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the documents submitted to be complete for construction. Plans: ASI instructions/ 13 plan sheets Plan review fee: $90 No additional square footage- No added valuation / .�-� Sincerely, � � , Shane Gremmer Plans Examiner SAFEbuilt Colorado P.O. Box 1618 Eagle, CO 81631-1618 (970)328-1790 shane.�emmer�u,SAFEbuilt.com Page 1 of 1 SAFEbuilt Colorado Eagle Office✓P.O.Box 1618✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631 Phone:(970)328-1790✓Toll Free:(877)428-6412✓Faac:(970)328-1791✓\\Eaglel\eagle shared drive�Plan Review\Vail�Front Door�B06- 0028\tov-b06-0029.7559 FAL.doc TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT � � l; 75 S. FRONTAGE ROAD � � VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW(SFR,P/S,DUP)PERMIT Permit #: B06-0028 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING'E'LJNIT 5 Applied . . : 02/13/2006 Parcel No...: 210108278002 Issued . . : 03/27/2008 Legal Description: Expires.....: O1/17/2007 Project No : PRJ06-0038 OWNER LODGE PROPERTIES INC 02/13/2006 PO BOX 7 VAIL CO 81658 ARCHITECT 4240 ARCHITECTURE, INC. 02/13/2006 Phone: 303-292-3388 1621 18TH STREET SUITE 200 DENVER CO 80202 License: C000001868 APPLICANT HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A CONTRACTOR HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A Desciption: VAILS FRONT DOOR BUILDING'E'UNIT 5 CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Occupancy Type Factor Sq Feet Valuation RESIDENTIAL/MULTFAM( ZONE 3 VB 116 .28 14, 557 $1, 692, 687 . 96 STORAGE/LOW HAZ (S2) ZONE 3 IA 115 . 18 345 $39, 737 . 10 Totals . . . 14, 557 $3 , 714, 875 . 00* Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 3,714,875.00 Fireplace Information: Restricted:Y #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pallet: 0 ****►�*r**rs******►�r*+*****r*+*r*�+*r+*�****t*****►**»*+*t*s**�*+*** FEE S UMMARY****++***+►r++r***�*+********+**s***�r�++*+.*+�.*..r�.�*+*+ t3uilding------> $15,518.5 o Restuarant Plan Review--> $o,0 0 Total Calculated Fees-----> $3 5,�98.4 2 Plan Check---> $10,0 8�.0 2 Recreation Fee------------> $10,18 9.9 o Additional Fees------------> $1,2 0 0.o o) Investigation-> $o.o o TOTAL FEES-------------> $3 5,7 9 8.4 2 Total Permit Fee-----------> $3 4,5 9 8.4 2 Wi11 Call-----> $3.oo Payments-------------------> $34,598.42 BALANCE DUE---------> $o.o0 +:s�**+*��*�#*��**�**:*****.*s*■«■***s*►���**.�****srrrr►.****r��**r*t*t*«***:.*+rt***s***�***s***+:*.*srs�s*s**rtrr**�********.�+**+*►►r*.**s■*. Approvals: Item: 05100 BUILDING DEPARTMENT 07/19/2006 cdavis Action: AP 12/05/2006 jplano Action: AP Approved Rev 1 root moditications tor insu. hours 07/09/2007 ep Action: DN Rev2 . IR4701 . No additional valuation. 10/04/2007 ependley Action: AP Rev4/IR5637 . Approved ASI E-056 Unit 11 Bu� No added valuation. Added plan review fee of 5120 . 00 due. 12/19/2007 jplano Action: AP Rev3/IR5633/ASI E-054, unit 5 buyer change: $180 due Item: 05400 PLANNING DEPARTMENT 07/19/2006 George Action: AP 11/O1/2007 GR Action: AP UNIT #11-ASI E-056 Item: 05600 FIRE DEPARTMENT 07/18/2006 McGee Action: AP 11/O1/2007 mcgee Action: DN ASI E-054 Unit 9 5A Plans showing changes to fire alarm and fire sprinkler are not stamped by BCER. 11/Ol/2007 mcgee Action: DN ASI Unit 11 5C Sheets A 152, 154, 156 show changes to tire alarm and tire sprinkler but plans arf stamped by BCER. O1/09/2008 JJR Action: DN ASI -055 UNIT 10 Changes to fire sprinkler and fire alarm not stamped by BCER. 02/13/2008 mcgee Action: AP ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP B06-0028 ASI E 054 Unit 9 (5A) Rev 3 02/13/2008 mcgee Action: AP B06-0028 ASI E 056 Unit 11 (5C) Rev 4 02/13/2008 mcgee Action: AP ASI E 054 Unit 9 (5a) Rev 3 Item: 05500 PUBLIC WORKS 07/14/2006 tk Action: AP Approved Building permit revisions dated rE 6/16/06 and 7/06/06 Item: 05550 ENGINEERING CIVILS �*�*�.+.+.«+�.*.*.*.*+*.*.*,*.**..:*���*.*.***:.*.*�*.*s*.*.*.*�s*.**�.�+*.���,**...*.*.*.*.*�:*.�*�**.*�*.*.*��.�*.*.*.*,�**.*.*,+�...**:�.�..*. See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. ��.r'.c�`.c"+�` �"..�e2c-�,u. SIGNATURE OF OWNER�ONTRACTOR FOR HIMSELF AND OWNER PAGE 2 ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B06-0028 as of 03-27-2008 Status: ISSUED ***********************************************************************************+******************** Permit Type: NEW(SFR,P/S,DUP)PERMIT Applied: 02/13/2006 Applicant: HYDER CONSTRUCTION, INC Issued: 03/27/2008 Job Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E'LJNIT 5 Parcel No: 210108278002 ******************************************************************************************************** CONDITIONS ******************************************************************************************************** Cond: 33 (PLAN)THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ******************++*****************************************************�****************** TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R080000356 Amount: $300. 00 03/27/200803 :40 PM Payment Method: Check Init: LC Notation: #59210/HYDER CONSTRUCTION INC. ----------------------------------------------------------------------------- Permit No: B06-0028 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $34, 598 .42 This Payment: $300.00 Total ALL Pmts: $34, 598.42 Balance: $0. 00 *+**********************+******************************************************************* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES -8, 069.62 PF 00100003112300, PLAN CK - project GFP012 8,369.62 ----------------------------------------------------------------------------- �t(a��;o� ��� � ��-���� �� ��� ATION L NOT I LETE OR UNSIGNED �� � Bu�ldin Permit# —dOd /k � �7��4����4�,�{��i����'�#'�4.��) �� O `� � � �'���.��� EVISION TO TOWN OF VAIL BUILDING PERMIT ,._, �li Separate Permits are required for electrical, plumbing, mechanical, etc.! '�,�� �,1 75 S. Frontage Rd. Vail, Colorado 81657 ***All Revision submittals must include the Field Set of approved plans. No further inspections � will be preformed until the revisions are approved. *** � CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact and Phone#'s: �e,. C. - (� l�.�. Z. 9 � - 4R`1 ATTENTION: OE ,CI�ARLIE,GREG,CHRIS Contractor Signature: � COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor 8� Materials REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ For Parcel# Contact Ea le Count Assessors Office af 970-328-8640 or visit www.ea !e-count .com ������ a�d� aa.t -i� �Job Name: v��`+5 ���� �� Job Address: S� �Q,` �Ne Legal Description Lot: Block: Filing: Subdivision: Owners Name: Address: Phone: v�,:� �Q� � Ar�hitecUDesigner: 4� Address: Phone: Engineer: � Q e`� Address: Phone: REASON FOR REVISIONS: ,a�ss E-o S4 ��: � SG. r �� G r w.•. vM � Work Class: New(� Addition ( ) Remodel ( ) Repair( ) Demo( ) Other( ) Work Type: Interior( ) Exterior( ) Both(� Does an EHU exist at this location: Yes ( ) No( ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( ) —� No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: —� No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes O No O Does a Fire Sprinkler Syst �, ,_ .:, FOR OFFICE USE ONLY***** � �[3a���e�3/,�d �� , � � @Tnl��.�8@ �!'4�• � p�a� ��e w �� , r Aa�ep€ed�B� �- � ?� �, ��� '" : , '° R a Fee{8�j �� " �� �� ,�.. ._ .�, ,. � � ..� _ .. �e e(1�1�?�. . rm�t:;,� °' c OUtSQUCC@�':TEftY1S � � 4 �° � WV � $ , � ..� . . � , . o. .. < , .. .- = << � ,:. . . � _.._ �� _ ;u L F:\cdev\FORMS\Permits\Building\building_revision_4-18-2007.doc Page 1 of 1 4/18/2007 � �- �; � � b411�# :, .a:�� � � ���. ������;��� Bnitding Departmeat Services December 19, 2007 Charlie Davis Chief Building Official, Town of Vail 75 South Frontage Road Vail, CO 81657 RE: PROJECT: ASI E-054 Unit 9 Buyer changes PERMIT NUMBER: B06-0028 REVISION NUMBER: 3 INTERNAL REF#: 5633 ADDRESS: 151 Vail Lane Dear Mr. Davis: SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003 International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the documents submitted to be complete for construction. Plans: ASI E-054 Unit 9 Buyer changes. Plan review fee: $180.00 No additional square footage- No added valuation Since , John Plano Plans Examiner/Senior Inspector john.plano(a�SAFEbuilt.com Page 1 of 1 SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631 Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fa3c: (970)328-1791✓V:�PIan Review\Vai1�F'ront Doar�B06-0028\tov-b06- 0028.Rev3_FAL.doc r �� Q l a�!o-� ��J `'� �(1�:.� �" ' � '2-� C�=-�- �—I � � N BE ACCE IF P S NED Buil g, �Oto T W a►0 • 9-Z �.(I ectiorrs) - . � . ���'���� � VISION T TOWN OF VAIL BUI D G MIT Separate Permits are required for electrical, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 **'�All Revision submittals must include the Field Set of approved plans. No further inspections will be preformed until the revisions are approved. *** CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact and Phone#'s: . � 7 � — ATTENTION: 0 ,CHARLIE,GREG,CHRIS Contractor Sig ure: COMPLETE REVISIONS EVALUATIONS FOR BUILDING PERMIT Labor& Materials REVISED AMOUNT: $ � ELECTRICAL: $ OTHER: $ PLUMBING: $ MECHANICAL: $ REVISED TOTAL: $ For Parcel# Contact Ea le Count Assessors Office at 970-328-8640 or visit www.ea le-count .com ParceE# a-� o a � Job Name: Job Address: � s k 1 Legal Description Lot: Block: Filing: Subdivision: Owners Name: ` Address: Phone: Architect/Designer: � 4 Address: Phone: Engineer: � W�lj Address: Phone: � REASON FOR REVISIONS: p�i G�c�Sb , ��� C �, "� Work Class: New(�. Addition ( ) Remodel ( ) Repair( ) Demo ( ) Other( ) Work Type: Interior( ) Exterior( ) Both �j�, Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Gas A liances Gas Lo s Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( ) No ( ) Does a Fire Sprinkler System Exist: Yes � No ,�v_ �� FOR OFFICE USE ONLY Qther Fees:' ,.. r.. .. . �ccupancy Group: �'—�] e �; �, :, � oe of Construction; Date Received:' , , : �.l� �, F:\cdev\r� : _ . T��N ��2/8/�0�� � "�ermits\Building\building_revision_11-23-2005.doc Page 1 of 2 � � ��«�� � �. �����InC. C�C3!��F��.[�t�? Bnilding Department Services October 3, 2007 Charlie Davis Chief Building Official, Town of Vail 75 South Frontage Road Vail, CO 81657 RE: PROJECT: ASI E-056 Unit 11 Buyer changes PERMIT NUMBER: BO6-0028 REVISION NUMBER: 4 INTERNAL REF#: 5637 ADDRESS: 151 Vail Lane Dear Mr. Davis: SAFEbuilt Colorado has reviewed only for their conformance to the provisions of the 2003 International Building Code as adopted by the Town of Vail. SAFEbuilt Colorado finds the documents submitted to be complete for construction. Plans: ASI E-056 Unit 11 Buyer changes. 25 plan sheets Plan review fee: $120.00 No additional square footage- No added valuation Sincerely, � Matthew Royer Building Official SAFEbuilt Colorado P.O. Box 1618 Eagle, CO 81631-1618 (970)328-1790 (877)428-6412 matt.ro.�(c�SAFEbuilt.com Page 1 of 1 SAFEbuilt Colorado Eagle Office✓P.O.Box 1618 ✓ 1286 Chambers Avenue,Unit 101 ✓Eagle,Colorado 81631 Phone:(970)328-1790✓Toll Free:(877)428-6412✓Fax:(970)328-1791✓Z:�Plan Review\Vail�Front Door�B06-0028\tov-b06- 0028.Rev4_FAL.doc 4��40 ARCHITECT'S SUPPLEMENTAL VAIL'S FRONT DOOR INSTRUCTION No. E-056 ro: Doug Thompson/ Hyder Construction, If1C. PROJECT NO:: 20693.OH 543 Santa Fe Drive DATE ISSUED 09.I 0.07 Denver, CO 80204 FROM: Michael Dire 303-825-1313 303-292-3388 The Work shall be carried out in accordance with the following Supplemental Instructions issued in accordance with the Contract Documents without change in Contract Sum or Contract Time. Proceeding with the Work in accordance with these Instructions indicates your acknowledgement that there will be no change in the Contract Sum or Contract Time. Architect's Supplemental Instruction Title: Building E—Revisions Associated with Buyer Changes for Chalet Unit#11. Reason for Change: To incorporate buyer requested changes into Unit#11 (SC) affecting architectural,structural,mechanical,plumbing and electrical. Description of Instructions: See attached drawings and annotations,as well as 8 '/z"x 11" specifications for design information. Sheet BR 11-A151 Plan"1"—Added: Bedroom to Multi-Purpose Room; Shower to Bathroom; a floor outlet to Multi-Purpose Room; Double rod and shelf to Storage Room; and Low Voltage Panels to Storage Room. Revised: Layout of Bathroom and Storage Room. Sheet BR 11-A152 Plan"1"—Added and Located: Speakers, motion detectors, sprinklers heads and smoke detectors to Reflected Ceiling Plan. Added: Note for all arched soffits to be flat. Added and Revised: Lighting in Multi-Purpose Room,Bathroom, F3edroom,and Storage Room. Revised: Arched soffit from Foyer to Multi-Purpose Room; and ceiling heights of Multi-Purpose Room and Bedroom. Sheet BR 11-A153 Plan"l"—Revised: Wall type to partition wall between Toilet Room and Jr. Master Bathroom to address graphisoft conflict with 3"waste down from above. Sheet BR ]1-A154 Plan"1"—Added and Located: Speakers, motion detectors,sprinklers heads and smoke detectors to Reflected Ceiling Plan. Added: J-Boxes to Bedroom and Jr.Master Bedroom; Lighting to Bedroom;and a note for all arcli soffits to be flat. Revised: Arched soffits in the Jr.Master Bathroom and between[he Foyer and Corridor Sheet BR 11 —A155 Plan"l"—For Information Only Sheet BR 11 —A156 Plan"i"—Added and Located: Speakers,motion detectors,sprinklers heads and smoke detectors to Reflected Ceiling Plan. Added: J-Boxes to Bedroom, Sr. Master Bedroom; Lighting to Bedroom; and a note for all soffiCS to be made flat. Revised: Arched soffits in Sr. Master Bathroom. --�.y.=».,m.a..�K,m.�.� Sheet BR 11 —A157 a" . " ` / Plan"1"—For Information Only �,' �"`� �_� _ �_� � w;,. � �! � •�°a �J! i,.i -�, ...,�,t( . S�fi��uilt Ga�orado 42�40 ARCHITECTURE INC 1621 Eighteenth Street Suite 200 Denver,Colorado 80202 The information contained in this message is privileged and�confidential intended only for the use of the individual(s)or entity(ies)named t 303.2923388 f 303.292.31 13 above. If the reader of this message is not the intended recipient,you are hereby notified that any dissemination,distribution,or copying of www.4240architecture.com this communication is strictly prohibited. If you have received this communication in error,please nolify 42/40 Architecture,Ine.immediately. 4�40 Sheet BR l 1 —A158 Plan"1"—Added and Located: Speakers,motion detectors,sprinklers heads and smoke detectors to Reflected Ceiling Plan. Sheet BR A251 Elevation"1"—Added: Keyless Entry/intercom box to West Elevation; and a note Co provide wiring,box and blocking for future satellite connection. Elevation"2"—Added and Located: Outside air intake termination to side wall of chimney. Sheet BR A252 Elevation"1"—For Information Only. Elevation"2"—For Information Only. Sheet BR-S150 For information only. Sheet BR-S153 For information only. Sheet BR-S155 For information only. Sheet BR-S I 57 For information only. Sheet BR-S 159 For information only. Sheet M 153 Plan"1"—Added: Ducting to new Bedroom. Revised: Hydronic Piping Layout. Plan"2"—For Information Only. Plan"3"—Far Information Only. Plan"4"—For Information Only General—Revised: Radiant Floor Zone Schedule. Sheet BR 11-P153 Plan"1"—Added: Waste&Vent and Hot&Cold water lines to Batllroom for new shower. Plan"2"—For Information Only. Plan"3"—For Information Only. Plan"4"—For Information Only. Sheet P403 Revised:Unit SC Waste and Vent IsomeMc. Sheet E008 Revised: Load Center Schedule. Sheet E153 Plan"1"—Added and Revised: Various A/V Equipment, lighting and Receptacles for revised floor layout. Plan"2"—Added: J-Boxes to Jr. Master Bedroom and Bedroom. Plan"3"—Added: J-Boxes to Jr. Master Bedroom and Bedroom. Revised: Sconces in Sr. Master Bathroom and Bathroom. Plan"4"—Added: J-Boxes to Living and Dining Room. General—Added: General and Detail Notes. � � � �..�, . e...., �..� �� �' ����; �J �� tT�:.��� �. �; 42�40 ARCHITECTURE INC 1621 Eighreenth Street Suite 200 � h It (; f(� a('�(� Denver,Colorado 80202 The information contained in this message is privileged and c nfidentia�teh�e�dTily'�fof the i7se�df'!h�'IPidRnVual(s)or ntity(ies)named t 303.292.3388 f 303.292.31 13 above. If the reader of this message is not the intended recipi e ere y no i ie a any issemin i n,or copying of www.4240architecture.com this communication is s[rictly prohibited. It you have received this communication in error,please notify 42/40 Architecture,Inc.immediately. � 4�40 Attachments and Enclosures: Architectural Sheets:BR 11-A151,BR 11-A152,BR 11-A153,BR 11-A154,BR ll-A155,BR I 1-A156,BR 11-A157,BR 1 I- A158,BR A251,BR A252 Structural Sheets: BR-S150,BR-S153,BR-S155,BR-S157,BR-S159 � � MEP Sheets: M153,BR I 1-P153,P403,E008,E153 Copy To: 4240 By: Jarvie Worcester/VRDC Mark Gee/Monroe&Newell Received By: Jim Ness/Monroe&Newell Jay Watson/ABS Consultants Steve Shayler/ABS Consultants Marcus Vahling/ABS Consultants �'j , t„�... � .,.�ndy Coc an/Slifer Designs Submit to Town of Vail: [�YES � NO i b+�,.'����..- ��n•-� �.ti ob Pieran=eli/Thul ev Ron inellii BCER !�`��� �1 � ,i �;�` �f, 42�40 ARCHITECTUREINC 5�����Il� '�'���r��0 1621 Eighteenth Street Suite 200 Denver,Colorado 80202 The information conlained in this message is privileged and confidential intended only for the use of the individual(s)or enlity(ies)named t 303.292.3388 f 303.29231 13 above. If the reader of this message is not the intended recipient,you are hereby notified that any dissemination,distnbution,or copying of www.4240architecture.com this communication is strictly prohibited. If you have received this communication in error,please nolify 42/40 Architecture,Inc.immediately. TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW (SFR,P/S,DUP) PERMIT Permit #: B06-0028 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Applied . . : 02/13/2006 Parcel No...: 210108278002 Issued . . . 07/21/2006 Legal Description: Expires.....: O1/17/2007 Project No : PRJ06-0038 OWNER LODGE PROPERTIES INC 02/13/2006 PO BOX 7 VAIL CO 81658 ARCHITECT 4240 ARCHITECTURE, INC. 02/13/2006 Phone: 303-292-3388 1621 18TH STREET SUITE 200 DENVER CO 80202 License: C000001868 APPLICANT HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A CONTRACTOR HYDER CONSTRUCTION, INC 02/13/2006 Phone: 303-825-1313 543 SANTA FE DRIVE DENVER CO 80204 License: 109-A Desciption: VAILS FRONT DOOR BUILDING 'E' UNIT 5 CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Occupancy Type Factor Sq Feet Valuation RESIDENTIAL/MULTFAM( ZONE 3 VB 116.28 14, 557 $1, 692, 687.96 STORAGE/LOW HAZ (S2) ZONE 3 IA 115.18 345 $39, 737.10 Totals. . . 14, 557 $3, 714, 875.00* Number of Dwelling Units: 2 Town of Vail Adjusted Valuation: 3,714,875.00 Fireplace Information: Restricted:Y N of Gas Appliances: 0 N of Gas Logs: 0 �t of Wood Pallet: 0 ***************************�*****************a:************�**�******* FEE SUMMARY*********************************�******�****************** Building------> $15,518.50 Restuarant P1an Review--> $0.00 Tota1 Calculated Fees-----> $35,798.42 P►an Check---> $l 0,0 8 7.0 2 Recreation Fee------------> $10,18 9.9 0 Additional Fees------------> $1,5 0 0.0 0) Investigation-> $0.00 TOTAL FEES-------------> $35,798.42 Tota1 Pernrit Fee-----------> $34,29s.42 Will Call-----> $3.00 Paymen[s-------------------> $34,298.42 BALANCE DUE---------> $0.00 *******************�**************************�*******************�*************************�:***************�************************************ Approvals: Item: 05100 BUILDING DEPARTMENT 07/19/2006 cdavis Action: AP Item: 05400 PI,ANNING DEPARTMENT 07/19/2006 George Action: AP Item: 05600 FIRE DEPARTMENT 07/18/2006 McGee Action: AP Item: 05500 PUBLIC WORKS 07/14/2006 tk Action: AP Approved Building permit revisions dated r� 6/16/06 and 7/06/06 Item: 05550 ENGINEERING CIVILS *******************************************************************************************************************+***************************** See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan and state that all the information as required is correct. I agree to comply with the information and plot plan, to cornply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHON -2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. SIGNATUR OF ER OR FOR MS D OWNEF PAGE 2 *�:**�*�**:�*�*�:**�:*�x****�x*�****�***�*�*�:*���*�**�*�:***�x��x***�:�*�x*�*�*�:*�**�*�*�x�:x*�:*�:*�*�:*��x�**�x***�x*�:*�:* CONDITIONS OF APPROVAL Permit#: B06-0028 as of 07-21-2006 Status: ISSUED �**�**�:*�x***��*�:***�:**�**�*�*:x�:*�*�**�*�***�*�***�*�:*�***�**�*:x*�:*�*=x*�x***�x��x�*�*�:*�*�***�*��*�:***�*�*** Permit Type: NEW (SFR,P/S,DUP) PERMIT Applied: 02/13/2006 Applicant: HYDER CONSTRUCTION, INC Issued: 07/21/2006 Job Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Parcel No: 210108278002 **�x***�:*�:*�:*��*�:****�x��*��x��x**�***����:*�x*��****�*�x��x**:x*��x***�x*�*�x*�x�*��x��x*�x*�*�:*�***��x*�x*:x*�*�*�x*�x�*�x*� CONDITIONS **�:�*�**�:*�:*�*�***�:*�:*��x****�*�:*�*�**�:***�:�*�:*�**�x�*�x*�*�*��*�:*�:*�x*�x�:��:�x�:**�*�x*�**�z*�*�*���:*�x**�*�x*�:*�:*�: Cond: 33 (PLAN) THIS PROJECT WILL REQUIRED A SITE IMPROVEMENT SURVEY. SUCH SURVEY SHALL BE SUBMITTED AND APPROVED PRIOR TO REQUEST FOR A FRAME INSPECTION. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ***��**********�******����*�**�******�********************************��***��**************� TOWN OF VAIL, COLORADO Statement *+***************************�x*:�****************************�********************�x*****��*** Statement Number: R060001047 Amount: $24, 190.4007/21/200612:12 PM Payment Method: Check Init: LC Notation: #53910/HYDER CONSTRUCTION INC. ----------------------------------------------------------------------------- Permit No: B06-0028 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $34,298.42 This Payment: $24, 190.40 Total ALL Pmts: $34,298.42 Balance: $0.00 *******************************************************:x****�:**************�x**************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 15,497.50 RF 11100003112700 RECREATION FEES 8,692.90 ----------------------------------------------------------------------------- � � u APPLICATION WlLL NOT BE ACCEPTED IF INCOMPLETE OR UNSI Project#: ���� �� Buildin Permit#: • � i" � � . •, ) ����''� a TOWN OF VAIL BUI�DING PERMIT APPLICATION Separate Permits are required for elect�icai, plumbing, mechanical, etc.! 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION Ge eral Contractor: Town of Vaii Reg. No.: Contact Person and Phone#'s: 2 0 —�, 1 v � � $�2�13t3 Email address: ��, �,,,�� Fau#: C3o3� g,�: �, Contractor Signature: � COMPLETE VALU S F UILDING PERMIT Labor&Materials BUII.DING: $ ELECTRICAL: $ OTHER:$ PLUMBING: $ MECHANICAL: $ TOTAL: $��� • � !� �s For Parcel#Contact Ea !e Coun Assessors O�ce at 970-328-8640 or�sif wJGw.ea le-count .com � ,,,, .�,l �l ��J �:a2��"C���.� Job Name: , 1 '�'�� v�'`S C � Job Address: �}4�1.,a` �t�N i '�-'r�u�,'.'t�' t.T'.yi., r17 . Legal Description Lot: ,�. Biock: Filing: Subdivision: ,/�i-y�. �z��'{�, Owners Name:U y �„��R�5 Address:�3 7 t3E � Phone:�� -13�� ArchitecUDesigner: Address: �b2 j /S ,5�" ..,�2, Go Phone:����,,2�2�33Pfr' Engineer: ,�p� ���„��, �'�, Address: �3I !�'yiv,ro� . � Fw�iZ Ct> Phone: 7 Detailed description of work: � F;Z�-/y7�� �iti rl'J ',�j�'=�- L ,' ,�/DCj��IZ �� ' � - '2 � .� ' "/ Work Class: New( Addition( ) Remodel ( ) Repair( ) Demo( ) Other( ) Work Type: Interior( ) Exterior( ) Both ( Does an EHU exist at this location; _Yes( ) No( ) Type of Bidg.: Single-family( ) Two-family(.3) Multi-family( ) Commercial( ) Restaurant( ) �ther( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No�T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T' e of Fire laces Pro osed: Gas A liances �i Gas Lo s �' Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes No O Does a Fire Sprinkler System Exist: Yes � No O � FOR OFFICE USE ONLY T e`of Construction " F�� �� ���� Oa�upancj►;Group ,,, „ Accepted By: TC�WN OF VAIL F�\r�lPV\F("1RM5\PFRMTTS\Ruil�iinnlhnilrlinn nr�rmit 11-�3-?005.DOC Paae 1 of 14 11/23/2005 �*********************************************************��******�************************* TOWN OF VAIL, COLORADO Statement **********************************************************�****************************�**** Statement Number: R060000138 Amount: $10,108.0202/16/200611:09 AM Payment Method: Check Init: JS Notation: 52915/HYDER CONSTRUCTION ----------------------------------------------------------------------------- Permit No: B06-0028 Type: NEW (SFR,P/S,DUP) PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $25,608.52 This Payment: $10,108.02 Total ALL Pmts: $10,108.02 Balance: $15,500.50 ************�x**********************�******************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 21.00 PF 00100003112300 PLAN CHECK FEES 10,087.02 ----------------------------------------------------------------------------- TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A07-0149 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING'E'UNIT 5 'A' Applied . . : 11/16/2007 Parcel No...: 210108278002 Issued . . . 12/07/2007 Project No : Expires . .: 06/04/2008 OWNER LODGE PROPERTIES INC 11/16/2007 PO BOX 7 VAIL CO 81658 APPLICANT ENCORE ELECTRIC 11/16/2007 Phone: 970-949-9277 ATTN: SHANNON GEIER 2107 W. COLLEGE AVENUE ENGLEWOOD COLORADO 80110 License: 668-5 CONTRACTOR ENCORE ELECTRIC 11/16/2007 Phone: 970-949-9277 ATTN: SHANNON GEIER 2107 W. COLLEGE AVENUE ENGLEWOOD COLORADO 80110 License: 668-5 Desciption: NEW FIRE ALARM SYSTEM FOR VAILS FRONT DOOR BUILDING 'E' UNIT 5 'A' &'B'-CONSTRUCTION OF A WOOD FRAME DUPLEX I'OWNHOME Valuation: $9,606.00 «*****�*��****++****s*****t**r+��*�a**r**►�r*►x*******t**�****r***x� FEE S UMMARY ■**s**********s******+*s******+a�sr+*********+rs*****�*v***► Electrical---------> $0.0o Total Calculated Fees--> $592.22 DRB Fee---------> $o.0 0 Additional Fees----------> ($2 3 2.0 0) Investigation----> $o.00 TotalPermitFee--------> $360.22 WiIICaII---------> $o.00 Payments------------------> $360.22 TOTAL FGES--> $592.22 BALANCE DUE--------> $0.00 **�*+**r*►*t*�*�sa**s*�***ss+**►*********r**s***.**********+***.*****a**�*****t*****+*r*.*.*s**sx*s**s*a**t*t*tr«t*a**:**s�********�s**t�***+�*** Approvals: Item: 05600 FIRE DEPARTMENT 11/19/2007 McGee Action: AP Change smokes in garage storage units to tl (typ) Recalculate battery backup to comply with 15 minute alarm time. Add detector to water entry room E-003 . Resubmit alarm sequence and matrix to have thermals trip alarm and red line requi: noted. Condo' s are under seperate permit, one per unit . Relocate smokes in living rooms to within 16 ft of top of stair (typ) . ..******..*�*.**.*...*.**..�.�...*..*.**.*.*..«*�*+...�.*.****.�....***�.****M.*.*.*.*..,:.*.*M**.*****.**..:�:*:***�.�**.«*.*.*.*..*.**.*.+,..** CONDITIONS OF APPROVAL *.�..*.�*.*.�...*�..**...«..***.*.*#��**.*.*....�.*.*«�*��*..�«.*..�....**..**.*.�.*.�..�.�*.*..*�*..,�.*�,�..*********�***.*.���*...«�.*�......** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TVVENTY-FOUR HOURS IN ADVANCE BY TELEPHO A 9-213 OM 5:00 -5 PM. _-�f:�/ � , SIGN URE OF O OR C RACT FOR HIMSELF AND OWNER ******************************************************************************************** TOWN OF VAIL, COLORADO Statement *****************************************+*+***********************************�****�******* Statement Number: R070002668 Amount: $360.22 12/07/200708:38 AM Payment Method: Check Init: JS Notation: 1862/ENCORE ELEC ----------------------------------------------------------------------------- Permit No: A07-0149 Type: ALARM PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 'A' Total Fees: $360.22 This Payment: $360.22 Total ALL Pmts: $360.22 Balance: $0.00 **************�***************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 FIRE ALARM PERMIT FEES 360.22 ----------------------------------------------------------------------------- TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FLZONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E06-0194 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Applied . . : 09/27/2006 Parcel No...: 210108278002 Issued . . . 10/30/2006 Project No : ���� .��,,��� Expires . .: 04/28/2007 OWNER LODGE PROPERTIES INC 09/27/2006 PO BOX 7 VAIL CO 81658 APPLICANT ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277 PO BOX 8849 AVON CO 81620 License: 331-E CONTRACTOR ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277 PO BOX 8849 AVON CO 81620 License: 331-E Desciption: ELECTRICAL FOR VAILS FRONT DOOR BUILDING 'E' UNIT SA, SB & SC - CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Valuation: $0.00 Square feet: 14557 ***�*****************************�*****************************�*** FEE SUMMARY ***********�************************************************ Electrical---------> $665.85 Total Calculated Fees--> $668.85 DRB Fee---------> $0.00 Additional Fees----------> $0.00 Investigation----> $o.oo Total Pemvt Fee--------> $66S.85 Will Call---------> $3.00 Payments-----------------> $668.85 TOTAL FEES--> $668.85 BALANCE DUE--------> $0.00 ******�****�************************************************************************�******************�*******************************�********�: Approvals: Item: 06000 ELECTRICAL DEPARTMENT 10/05/2006 mroyer Action: AP Item: 05600 FIRE DEPARTMENT ****�*****�:***************�********************************�*�******�:**�*�****�*******�**�**************�****���*********************���********* CONDITIONS OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *********�****�:**************************�*****************************�************************************************************�**�+******** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. �, ********************************�*********************�****************��*****�************* TOWN OF VAIL, COLORADO Statement **�x�*********************************�:****************:x**************�x***********�********** Statement Number: R060001839 Amount: $668.85 10/31/200605:07 PM ` Payment Method: Check Init: DDG Notation: Encore Elec 20503 ----------------------------------------------------------------------------- Permit No: E06-0194 Type: ELECTRICAL PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $668.85 This Payment: $668.85 Total ALL Pmts: $668.85 Balance: $0.00 �**�**************�******************:x*:�*****�**�x****����*********************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 665.85 WC 0010000311z800 WILL CALL INSPECTION FEE 3.00 ----------------------------------------------------------------------------- APPLICATION WILL NOT BE ACCEPTED IF INCOiNPLETE OR UNSIGI����.-aC� (� / / Project #: � �.�(� � _.. �� �[, Building Permit #: (� •- �UZ `�'' � Electrical Perrnit #: ` � � 970-479-2149 (Inspections) TOWN OF f��4i� � TOVI/N OF VAIL ELEC7'RICAL PERMIT APPLICATION 75 S. Frontage Rd. �� Vail, Colorado 81657 G � $,.._ CONTRACTOR INFORMATION Electrical Contractor: Town of Vail Reg. No.: Contact and Phone #'s: ����r� �.�.�c�� 33 � — � ;���1� ��ri� �- E-Mail Address: ���� ��� � n����. _ L�� Contractor Si nature: �- e COMPLETE SQ. FEET FOR NEW BUILDS and VALUATIONS FOR ALL OTHERS (Labor & Materials) AMOUNT OF SQ FT IN STRUCTURE: �� �� � ELECTRICAL VALUATION: $ Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www,ea le-coun ,com for Parce/# Parcel # �1� s t� ��7 $'t�C��. Job Name: va�� ����fi ��JU� Job Address: l�� ��`'��.. �.�� �'�• ��:1 6 (�.�,Y�C � 'f j 1{� -��' � �'. Legal Description Lot: Block: Filing: Subdivision: Owners Name:�� e � r.�.�� Address: �� �'�� -7 Phone: �-2 �_ �0 3� Engineer: Add ss: Phone: � (�..� �Z 3 fi�.n,,.r-�t,�. P�..�..w o 3 -�z� - 6 z.�o Detailed description of work: �/�� �S ,�-v n--�- �,�,�- ��L;� ��1� '� �}� �}- ,�j V' c��s�-v c-�-��r� e� u �v� _�--a:��e �� i�� �v� i�vm Work Class: New J� Addition ( ) Remodel ( ) Repair ( ) Temp Power ( ) Other ( ) Work Type: Interior ( ) Exterior ( ) Both � Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family( ) Duplex (j0� Multi-family( ) Commercial (�J Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: � No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No Does a Fire Alarm Exist: Yes ( ) No (X[ Does a Fire Sprinkler System Exist: Yes ( ) No (� **kx�F*kk!:�'c�: :����:�*xxx�:�:�*xx��::���:��F01t OFFYCE USE ONLY�:���xx�:*�x*,����x�xxx:��:��::�**�x:�;���:x�X:� � ` � '� Other Fees Date Received: �� DRB Fees. Acce ted B : ` Planner Si n-off: V �, \\Vail\data\cdevAFORMS\PE RM ITS\ELECPERM.DOC 07/26/2002 Page 1 of 1 Lynne Campbell - overage From: Diane Golden To: Lynne Campbell Date: 11/O1/2006 1:28 PM Subject: overage Lynne, permit # E06-0194 for Encore Electric overpaid by $20.00 Jacque has been notified. Let me know if I need to give you any more information. Town of Vail *�+� CLf5TD�4ER RECEIRT *** t7per: AJRIVUSZ Type: FB Drewer: 1 I�ate: 11J0�/Q�5 �i Re�eipt no: 158@7 Description �uantity Aeaunt M5 MISCELLANEDUS G/L account nueberl.a@ 5�0.0[� �A�1@d�[�s133100 EtJCORE ELECTRI� aUER F'RYMENT/F�ERMIT#EQ�6-@194 Tender detail CK CF�CIS �`�Ns fc'Q�.04� Total tendered s��,�� Total pay�ent f20.0@ frans date: li/��/Q�6 Tioe: 14:4c:33 THANH YDtJ F4R YGllk F'NYMENT! file://C:�Documents and Settings�Administrator\Local Settings\Temp\GW}00OO1.HTM 11/Ol/2006 TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E06-0194 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Applied . . : 09/27/2006 Parcel No...: 210108278002 Issued . . . 10/30/2006 Project No : Expires . .: 04/28/2007 �+�C�•-UU�, • OWNER LODGE PROPERTIES INC 09/27/2006 PO BOX 7 VAIL CO 81658 APPLICANT ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277 PO BOX 8849 AVON CO 81620 License: 331-E CONTRACTOR ENCORE ELECTRIC 09/27/2006 Phone: (970) 949-9277 PO BOX 8849 AVON CO 81620 License: 331-E Desciption: ELECTRICAL FOR VAILS FRONT DOOR BUILDING 'E' UNIT SA, SB & SC - CONSTRUCTION OF A WOOD FRAME DUPLEX TOWNHOME Valuation: $0.00 Square feet: 14557 *********�*******�*****�****x***a:**************�************m*�**** FEE SUMMARY ******a***************xx*******************�**�************* Elec[rical---------> $665.85 Total Calculated Fees--> $668.85 DRB Fee---------> $0.00 Additional Fees----------> $o.00 Investigation----> $0.00 Total Pemut Fee--------> $668.85 Will Call---------> $3.00 Payments------------------> $668.85 TOTAL FEES--> $668.85 BALANCE DUE--------> $0.00 ****************************�****************�****�****�*****�**********�****�*****************************�********�:**************************** Approvals: Item: 06000 ELECTRICAL DEPARTMENT 10/05/2006 mroyer Action: AP Item: 05600 FIRE DEPARTMENT �**********************�*************************«******�***********�********************«*****�****************��****************************�** CONDITIONS OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. *****************�*****�*************�****�**�************�**�***«*********�**�************************************�***************************�* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. PI328L PAGE: 1 F P O E N T R Y / R E C E I V I N G R E P O R T -------------------------------------------------------------------------------- FPO NUMBER : F28618 DATE RECEIVED: 11/14/06 REMARKS : REFUND OVER PAYMENT ON THE CHECK RECEIVED BY: LC ENTERED:11/14/06 8 : 55 BY: LCAMPBELL VENDOR: 0000001 - Encore Electric INVOICE NUMBER: E06-0194 INVOICE DATE: 11/14/06 INVOICE POSTED: 11/14/06 8 : 55 BY: LCAMPBELL PAYMENT DUE: 11/17/06 AMOUNT: $ 20 , 00 ACCOUNT# PROJ# AMOUNT ITEM DESCRIPTION -------------- ------ -------------- ---------------- 00100003193100 $ 20 . 00 REFUND OVERPAYMENT ON E06-0194 ********#*#*********#�*t�**####**#**#*#*#####**�#**#*****�***##*#***##*#*#**#*�**#***#*#**#* TOWN OF VAIL, COLORADOCopy Reprinted on 11-14-2006 at 08:50:02 11/14/2006 Statement **��********�*******************************************�****�****�**************�x********** Statement Number: R060001839 Amount: $668.85 10/31/200605:07 PM Payment Method: Check Init: DDG Notation: Encore Elec 20503 ----------------------------------------------------------------------------- Permit No: E06-0194 Type: ELECTRICAL PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $668.85 This Payment: $668.85 Total ALL Pmts: $668.85 Balance: $0.00 ****************�:****************************************+**********�:*********************�x* ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 665.85 WC 00100003112800 WILL CALL INSPECTION FEE 3 .00 ----------------------------------------------------------------------------- (? Q � � l \ � ' � �,� CQ C. �'t.; c�-�.��..�... .� C�`�-�����-� �- � � �"� (..���. � � . �� .C,v,�=-E-►�-�. � � �...� �r-�--�-��`-°� � ��--� ��. � � � —oc7 _ 1 —���� � � n--� � , G� , TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M06-0280 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING B' UNIT 5 Applied . . : 10/OS/2006 Parcel No...: 210108278002 Issued . . . 10/24/2006 Legal Description: Expires . .: 04/22/2007 Project No : OWNER LODGE PROPERTIES INC 10/05/2006 PO BOX 7 VAIL CO 81658 APPLICANT HEATING & PLUMBING ENGINEERSIO/05/2006 Phone: (720) 274-0073 715 VALLEJO STREET . DENVER � COLOR.ADO 80204 License: 347-M CONTR.ACTOR HEATING & PLUMBING ENGINEERSIO/05/2006 Phone: (720) 274-0073 715 VALLEJO STREET DENVER COLOR.ADO 80204 License: 347-M Desciption: VAILS FRONT DOOR BUILDING 'E' UNIT 5-MECHANICAL Valuation: $206,200.00 Fireplace Information: Restricted: /t of Gas Appliances: 0 /f of Gas Logs: 0 N of Wood Pellet: 0 ***********************************************************�******** FEE SUMMARY ***********�************************************************ Mechanical---> $4,140.00 Restuarant Plan Review--> $0.00 Total Calculated Fees---> $5,1�8.o0 Plan Check---> $1,03 5.0 0 TOTAL FEES--------------> $5,17 8.0 0 Additional Fees-----------> $0.0 0 Investigation-> $0.00 Total Pernut Fee----------> $5,178.00 Will Call-----> $3.00 Paymen[s-------------------> $5,178.00 BALANCE DUE---------> $o.00 +***************�*******�m�***+******�*******************+*****«**************************+***+*****************�****�*�**�***********+***+*+*+** Item: 05100 BUILDING DEPAR.TMENT 10/12/2006 mroyer Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG. ) : COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG. ) : BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond: 25 (BLDG. ) : GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC. . Cond: 31 (BLDG. ) : BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG. ) : PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004 .6. ****�********************�**************�*************�*************************************************************************�************�*** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM. � SIGNATURE OF O OR CONTRACTOR FOR HIMSELF AND OWNEF � � ********�*****��*******�*************�*�*�*******�**�****+*�+�*��*********�***+��***�******* TOWN OF VAIL, COLORAI)OCopy Reprinted on 10-24-2006 at 12:40:06 10/24/2006 Statement �x:x***********:x*********:x**�x+********:��x�x******************************+******�*************** Statement Number: R060001645 Amount: $5,178.00 10/06/200602:00 PM Payment Method: Check Init: JS Notation: 94681/HEATING & PLUMBING ENGINEERS, INC. ----------------------------------------------------------------------------- Permit No: M06-0280 Type: MECHANICAL PERMIT � Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING �E� UNIT 5 Total Fees: $5, 178.00 This Payment: $5,178.00 Total ALL Pmts: $5, 178.00 Balance: $0.00 *********************************************************************�x******�:******�****�x*** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ --=--------- MP 00100003111100 MECHANICAL PERMIT FEES 4, 140.00 PF 00100003112300 PLAN CHECK FEES 207.00 PF 00100003112300, PLAN CK - project GFP012 828.00 WC 00100003112800 WILL CALL INSPECTION FEE 3 .00 ----------------------------------------------------------------------------- r APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNEqY,� c���,.�� TOV Project #: Uv� � � 0�_ O � � � Buiiding Permit #: -o�Z g - � Mechanical �ermit �: Q • Z� � ��Q�y�� � 970-479-2149 (Inspections) TOWN OF VAIL MECHANICAL PERMIT APPLICATION 75 S. Frontage Rd. Permit will not be accepted without the following: Vail, Colorado 81657 Provide Mechanical Room Layout drawn to scale to include: ❑ Mechanical Room Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue,Vent and Gas Line Size and Location ❑ Heat Loss Calcs. ❑ Equipment Cut/Spec Sheets CONTRACTOR INFORMATION Mechanical Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: I-�A-r,r,�, +QIkM�� r,� C��j�:,,�«� 3`I "1 - `�Z� - �t �-( `�� `l`�I . E-Mail�ddress: S�t�e r3 �� !�vC , �� Fax#: �ZO� `Z°?y-p �-j/`�, Contractor Signature: t! COMPLETE VALUATION FOR MECHANICAL PERMIT Labor& Materials MECHANICAL $ Zt�Y��ZCo � tooc � ?��� X ZO - � ���Z�r X t,? 'S = � S 1 �a� � Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www,ea /e-coun ,com3for Parce� Parcel # ]ob Name: v�-'` ��, a=�-•...� ;:r°.r�_ `?��rc,�. ;. � ]ob Address: �7`/ C"u� C_r�ec_�,� ��Z tv n t� 5 t,���., r� �!�,� `� _ Legal Description Lot: Block: Filing: Subdivision: Owners Name: �R�L R�.�-.rts Address: °• 4p'� �S4 Phone: prue(�-a.�:,t �vc�v c z'f��a �/'7a-��s - �35? Engineer: �S Address: i��3o r�.'''��� 5�1 tc �tL:� phone: F=`f' ��'•�', �'3 ozvz- - �'�°6Z.�'� ���p Detailed description of work: r„��h�.,,,,� - � - ' ��'Z_. /'r F',rr`, � s`Q t3 t¢`r•s}a->, '/� C.i9 L�c°±,�' f eP'�;,�r//o±(.. s �;�,.�; F^E �� '$��'S{c-ati- t� � i _ ti�«a_f...e`°+"` i715�qet1 �+e /�3.5 �;�Y r n s-�f; ,,� r_��`.��f f�``�"t�r az^t t�$`, Work Class: New(� Addition ( ) Alteration ( ) Repair( ) Other( ) Boiler Location: Interior(e�) Exterior O Other O Does an EHU exist at this location: Yes O No(k) Type of Bldg: Single-family( ) Duplex( ) Multi-family(,Y) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No T e of Fire laces Existin : Gas A liances Gas Lo s Wood Pellet Wood Burnin No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No ( ) Z��**************x�***x�*FOR OFFICE USE ONLY*********************x�******* �� Other Fees: Date Received: r � � Accepted By: ,�/ 5` 'Y F:\cdev\FORMS\Permits\Building\mechanical_permit_11-23-2005.DOC 11/23/2005 � - ******************************************************************************************** TOWN OF VAIL, COLORADO Statement *******************************************************************************************� Statement Number: R060001645 Amount: $5,178.00 10/06/200602:00 PM Payment Method: Check Init: JS Notation: 94681/HEATING & PLUMBING ENGINEERS, INC. ----------------------------------------------------------------------------- Permit No: M06-0280 Type: MECHANICAL PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING �E' UNIT 5 Total Fees: $5,178.00 This Payment: $5,178.00 Total ALL Pmts: $5,178.00 Balance: $0.00 ***********************************************t******************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 4,140.00 PF 00100003112300 PLAN CHECK FEES 207.00 PF 00100003112300, PLAN CK - project GFP012 828.00 WC 00100003112800 WILL CALL INSPECTION FEE 3.00 ----------------------------------------------------------------------------- TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Permit #: P06-0129 Job Address: 174 GORE CREEK DR VAIL Status . . . : ISSUED Location.....: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Applied . . : 10/OS/2006 Parcel No...: 210108278002 Issued . . . 10/24/2006 Legal Description: Expires . .: 04/22/2007 Project No : OWNER LODGE PROPERTIES INC 10/05/2006 PO BOX 7 VAIL CO 81658 APPLICANT HEATING & PLUMBING ENGINEERSIO/05/2006 Phone: (720) 274-0073 715 VALLEJO STREET DENVER COLORADO 80204 License: 353-P CONTR.ACTOR HEATING & PLUMBING ENGINEERSIO/05/2006 Phone: (720) 274-0073 715 VALLEJO STREET DENVER COLOR.ADO 80204 License: 353-P Desciption: VAILS FRONT DOOR BUILDING 'E' UNIT 5-PLUMBING Valuation: $137,600.00 Fireplace Information: Restricted: ?? #of Gas Appliances: ?? #of Gas Logs: ?? #of Wood Pallet: ?? *******************�*********�************************�****�********* FEE SUMMARY x:�**************************�******�************�********:�*� Plumbing---> $2,070.00 Restuarant Plan Review--> $0.00 Total Calculated Fees---> $2,590.50 Plan Check---> $517.5o TOTALFEES--------------> $2,590.50 Additional Fees-----------> $0.00 Investigation-> $0.00 Total Permit Fee----------> $2,590.50 Will Call-----> $3.0 0 Payments-------------------> $2,5 9 0.5 0 BALANCE DUE---------> $0.00 **********�:******************************x********************�*:�***********�*******�************************************************************ Item: 05100 BUILDING DEPARTMENT 10/12/2006 mroyer Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ***************�*********************************************************�***************************************************************�**�***� DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM-4 PM: _,, ..._- ,�--- _ SIGNATURE O ER OR CONTRA TOR FOR HIMSELF AND OWNEF �' *****�*********�*****�********�**�*************************�***************�********�******� TOWN OF VAIL, COLORADOCopy Reprinted on 10-24-2006 at 12:51:09 10/24/2006 Statement *****************************************************�:*�:****�*********************�********* Statement Number: R060001642 Amount: $2,590.50 10/06/200601:52 PM Payment Method: Check Init: JS Notation: 94681/HEATING & PLUMBING ENGINEERS, INC. ----------------------------------------------------------------------------- Permit No: P06-0129 Type: PLUMBING PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E� UNIT 5 Total Fees: $2,590.50 This Payment: $2,590.50 Total ALL Pmts: $2,590.50 Balance: $0.00 ******************************************�:**************************+********************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 103.50 PF 00100003112300, PLAN CK - project GFP012 414.00 PP 00100003111100 PLUMBING PERMIT FEES 2, 070.00 WC 00100003112800 WILL CALL INSPECTION FEE 3 .00 ----------------------------------------------------------------------------- �� •-'' '` APPUCATION WI�L NOT BE ACCEPTED IF INCOMPLETE OR UNSI -V Q Project #: _���'�O'�� V � Building Perm�t#: � 6 Z� �f�'��f�j���t{r�'/�1 � /� /'� � Plumbing Permit#: � iY,riT V��� F � ( \ � � U ` 9 0-479-2149 (Inspect ons) 75 S. Frontage Rd. `J Vail, Colorado 81657 TOWN OF VAIL PLUM�ING PERMIT PLICATION CONTRACTOR INFORMATION Plumbing Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: �„ �►- kn��s:n� L��n�€r3 3s3 —'P �� �3(�rsf �1Z�_zi� -Z�� E-Mail ddress: ��,,;�, r� ,. . '� C.�� �-, ._ �1 C- • c Gwc, Fax #: �Z D -Z? Contractor Signature: y° O��g. COMPLETE VALUATION FOR PLUMBING PERMIT(Labor& Materials) PLUMBING: $ �,3� (-�p b ;(opb = 13 rj�(o � �C ti S - Zo(� f X �.Z"5 � `�Z J''��'j Z� Contact Ea /e Coun Assessors Office at 970-328-8640 or visit www,ea /e-coun�com for Parce/# Parcel # )ob Name: vA ; 1 � t�=r�r�-t {_,r�z;,� '��, r���r ;,�r,,�#. s � � Job Address: j 7`� G�'E Cn_°P rC Ia� Vf},�- Gv �/6 S'7. Legal Description Lot: Block: Filing: Subdivision: Owners Name: ���� c=�f.c� � Address: Po Bc�k S �e�� t r,.k , ,,� `l g���:'c� Phone• Engineer: �QS Address: �53� tb*� �7���ys - Z3S Z_ i?�,�� �� � 5� 5�r{� �tt?o Phone• Detailed description of work: �1 ;� ° '� - CZ 3 - (��L1, ��r�R°L� ��3 g c�.�, i°�tt�� ��` �' EGi,v ,i t'�a�� f�./}�--� 7a � +'� /y"`.e,i , � �r i?r.,�t r9�,�`� ��s+ �r`�''C c"'f I}� r'� «�'�?f�_e� .b � /'�-�"_�s `�e� �{r� �,d � ��5. Work Class: New(k) Addition O Alteration ( ) Repair( ) Other( ) Type of Bldg.: Single-family O Duplex O Multi-family(f�c) Commercial ( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: X�xX��XZXF �xX�""""""""""`�""x"�"`xxx*FOR OFFICE USE �� x ONLYxx�xx��xxxx�xx��*xx�*xxx�xxx�xxxxx*�x 1� Other Fees: Date Received: ��� Acce ted B : � � 5 �q� Z � F:\cdev\FORMS\PERMITS\Building\plumbing_permit_11-23-ZOOS.doc Page 1 of 1 11/23/2005 � *****�***************�*************************�******************************************** TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R060001642 Amount: $2,590.50 10/06/200601:52 PM Payment Method: Check Init: JS Notation: 94681/HEATING & PLUMBING ENGINEERS, INC. ----------------------------------------------------------------------------- Permit No: P06-0129 Type: PLUMBING PERMIT Parcel No: 2101-082-7800-2 Site Address: 174 GORE CREEK DR VAIL Location: VAILS FRONT DOOR BUILDING 'E' UNIT 5 Total Fees: $2,590.50 This Payment: $2,590.50 Total ALL Pmts: $2,590.50 Balance: $0.00 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 103.50 PF 00100003112300, PLAN CK - project GFP012 414.00 PP 00100003111100 PLUMBING PERMIT FEES 2,070.00 WC 00100003112800 WILL CALL INSPECTION FEE 3 .00 ----------------------------------------------------------------------------- B06-0028: Entries for Item:90 - BLDG-Final 15:19 06/18/2013 Action Comments By Date Unique_ Ke qp mgsafe 11/14/2008 A000119 975 qp mgsafe 01/21/2009 A000122 104 Total Rows:2 Page 1 E06-0194: Entries for Item:190 - ELEC-Final 15:19 06/18/2013 Action Comments By Date Unique_ Ke AP mgsafe 01/21/2009 A000122 106 Total Rows: 1 Page 1 M06-0280: Entries for Item:390 - MECH-Final 15:19 06/18/2013 Action Comments By Date Unique_ Ke AP mgsafe 01/21/2009 A000122 115 Total Rows: 1 Page 1 P06-0129: Entries for Item:290 - PLMB-Final 15:20 06/18/2013 Action Comments By Date Unique_ Ke qp mgsafe 01/21/2009 A000122 116 Total Rows: 1 Page 1