Loading...
HomeMy WebLinkAboutB08-0072 B07-0360 �9� Communit� Developr�zent Deprzrtl�ierit 75 Soutli Froritrzgc Rorrd V�zil, Colorc�do USA 81657 CERTIFICATE OF OCCUPANCY This certificate is issued put•suant to tlie requirenlents of Title 10, Section 10-1-2, ADOPTED COD�S of the Vait 'Totivn Code certifying d�at, at the time of issuance, dlis structure was found to be substantially ii1 compliance with the variolis ordinances of the town regulating buildii�g construction or use for the following: Name and description of project CORE AND SHELL R�SIDENTIAL CONDO AND RETAIL SPACES Address oE project: 288 BRIDGE STREET Owner name and address ROSENQUIST RICHARD N. - BROWN TEFPREY 385 CLAYTON SZ' DENV�R,CO 80206-4228 IBC Edition: Permit Nuulber(s) 2003 B08-0072 Occupancy Group(s): R2/M/!12/B Type(s) of Construction: V ��� �, ;� `Martin Haeberle, Chief Building Official Occupant Load: VARIES Sprinkler System Y�N Type: 13 �/o ��� � Date � T � TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S.FRONTAGE ROAD VAIL,CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIlbIES ADD/ALT COMM BUILD PERMT Permit # B08-0072 Project# � �p 1- a�C 3�( Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.......: RUCKSACK BUILDING Applied.. . : 04/07/2008 ' Parcel No....: 210108244003 Issued. . . : �05�8f�998-- l 1� (�-!f� Expires.....: 11/16/2008 OWNER ROSENQUIST,RICHARD N. - BROW 04/07/2008 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT HIGHLAND BUILDERS CORPOR.ATIO 04/07/2008 Phone: (719) 499-9248 2598 Palmer Park Blvd. Colorado Springs CO 80909 License: 208-A CONTRACTOR HIGHLAND BUILDERS CORPORATIO 04/07/2008 Phone: (719) 499-9248 2598 Palmer Park Blvd. Colorado Springs CO 80909 ' License: 20$-A Desciption: CORE AND SHELL FOR NEW SECOND FLOOR RESIDENTIAL CONDO AND GROUND FLOOR RETAIL SPACES IN TI-�BRIDGE STREET BUILDING (FORMER RUCKSACK) Occupancy: mixed Type Construction: VA , Valuation: 1,348,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 i�►tiitt#*iit!#i►ttti#t4tfti�titittl�*ttRRitiiii+F#t4�t�►ii4#4#if#ttk FEE SUMMARY *i4f4t#tti►�i�ii4�i1�#�Iitiftiiit�M/itRiiit#ittti�tiiitii4ttt• Building—= $6,8 7 8.95 Restuarant Plan Review--> $0.0 0 Total Calculated Fees--> $3 9,15 9.2 7 Plan Check--� $4,4 71.3 2 Recreation Fce------> $0.0 0 Additional Fees---> $84,917.2 5 Investigationa $o.0 0 TOTAL FEES > $3 9,15 9.2 7 Total Permit Fce------> 12 4,0 7 6.52 Wi11 Call—> $4.00 Payments —> 124,076.52 BAI,ANCE DUE---> $o.0 0 •iiit4tf#tit►t#ltttt�iftti�iit�*ttti#tti►ii/i##�kM�Y�ki►itti*t#*ti#tiiitit#t#ittiti�#4�kt*t#iti�ti#►i44t#ttittiiit*itttltii►t+liitiittittRltt�i�iiti�t Approvals: Item: 05100 BUILDING DEPARTMENT � 04/21/2008 cgunion Action: CR corrections required. sent comments to applicant and architect F:\cdev\CHRIS\PERMIT.COMMENTS\B07-0307\B07-0307.DOC .. :,. , :'�.; ��y.:t ,'' f , B - '� :t_: 05/Ol/2008 cgunion �Action: CR second check review comments sent F:\cdev\CHRIS\FERMIT.COMMENTS\B08-0072\B08-0072.secondcheckDOC.DOC OS/05/2008 cgunion Action: AP APPROVED REVISED, CORRECTED PLANS DATED 5/1/OS 11/14/2008 cgunion Action: AP APPROVED REVISED PLAN SETS DATED 11/14/08 Item: 05400 PLANNING DEPARTMENT 04/16/2008 sdh Action: AP Approved, with additional conditions placed on issuance of permit. 11/14/2008 RLF Action: AP APPROVED 11/14/OS REVISIONS ' Item: 05600 FIRE DEPARTMENT OS/09/2008 mcgee Action: AP Fire sprinkler and fire alarm permits and plans required. Item: 05500 PUBLIC WORKS 05/13/2008 csalli Action: AP itif►iit�i/ttiitittif4ttRK�ti#iit�tf#�l�t4ti�iit4tit*�1*#i#iiiiti4#i►4tift�t#tiiit�ktt4ittt►f4iFt#i1��tiit�Y#iltFiit��litit►#tfit►it/+Ittif►ittttitii#/ See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the informatio completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and p , ly with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision co desi ' w approved,Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS ADVANC AT 479-2149 OR AT OUR OFFIC OM 8:00 AM• 4 PM. . S ATURE OF OWNER O NTRACTO AND OWNER ;,,� ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B08-0072 as of 11-17-2008 Status: ISSUED ************s*****s*********************************s*******s******************************s*****s****** Permit Type: ADD/ALT COMM BUILD PERMT Applied: 04/07/2008 Applicant: HIGHLAND BUILDERS CORPORATION ' Issued: OS/20/2008 (719)499-9248 To Expire: 11/16/2008 Job Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Parcel No: 210108244003 Description: CORE AND SHELL FOR NEW SECOND FLOOR RESIDENTIAL CONDO AND GROUND FLOOR RETAIL SPACES IN THE BRIDGE STREET BUII,DING (FORMER RUCKSACK) **********************************s************Conditions:***s*s**********s************************s****ss Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTEA Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0009897 The Developer shall submit executed agreements for encroachment,shoring and/or temporary access on,over, under or across adjacent properties. Such agreements shall be executed by and between the developer and the adjacent property owners,inclusive of the Town of Vail,prior to issuance of a building permit,for any and all improvements,temporary access or dishubance proposed off of Parcels 1,2,3,and 4;parts of Lots C and D,Vail Village First Filing. Cond: CON0009957 SEPERATE PERMITS WILL BE REQURED FOR FUTURE RETAIL SPACES 204-207 AND FINISH OF FUTURE SECOND FLOOR RESIDENTIAL UNIT. THIS BUII.,DING PERMIT IS FOR CORE AND SHELL ONLY. Cond:CON0009958 SPECIAL INSPECTION REPORTS REQUIRED PER STATEMENT OF SPECIAL INSPECTION. SEE PLANS Cond:CON0009972 Fire alazm permit required Entry: OS/09/2008 By: mcgee Action: AP Entry: OS/09/2008 By: mcgee Action: AP Cond:CON0009973 Fire sprinkler permit required. Cond: CON0010455 COMPLETE FIRESTOPPING PACKAGE TO BE SUBMITTED AS A DEFFERED SUBMITTAL ITEM SEE ARCHITECTS RESPONSE TO PLAN CHECK COMI��NTS Cond:CON0010457 :� �TI�APPLICANT SHALL REPLACE EXISTIl�TG ROOF OVER RESIDENTTAL +`AND ON TOWER WITH DAVINCI SHAKE AS APPROVED BY TI�DRB UNLESS FUTURE DRB APPROVAL IS RECENED FOR A CHANGE TO MATERIALS. Cond:CON0010458 Tf�APPLICANT SHALL REPLACE ALL RAILINGS ON OR ADJACENT TO TI�EAST ELEVATION WITH WOOD RAII,ING TO MATCH EXISTING RAILING. Cond:CON0010459 N4 CONSTRUCTION MAY ENCROACH OVER THE PROPERTY LINES `° Development Review Coordinator •._ . _ � �. �� �: � � ' � � �� �' 75 South Frontage�Road � � � �� �� � " Vai�r CD`�$�.�J�7 � ° `� �r, ��_�� . " ..,:.; Phone: 970-479-2128 :; � .� �� �. � �,;,�,. - ° Faxi970-479-2452 �� ��_� ��� �� � �,� � , , * � ���R�ctions: 97Q-479-2149' ___. ��� ��'���'�� ��` .. Transmittal Form Revision Submittals: 1. "Field SeY'of approved plans MUST accompany revisions 2. No further inspections will be performed until the revisions are approved &the permit is re-issued. 3. Fees for reviewing revisions are $55.00 per hour(2 hour minimum), and are due upon issuance. . . _.._ _. __ (J/Revisions _ Permit#(s) information applies to: Attention: O Response to Correction Letter �� , ° attached copy of correction letter ` ' u`���� � �D� oZ ��a�J"j S��c��1(lCZ��( ( ) Deferred Submittal ( ) Other Project Address: ��� �` j�� ? 5 r Description/ List of Changes: dC ' Contact Information Company: 6[ ����b4 c,f� �cJ s/'1 O�-�f�7� Company Ph: ���- ��%'���(�Fax: Y��- � C� � Contact Name: /l�'tl��} �4�L 1��(�3f C� Contact Ph: �l�/ Z y�' ���� Cell: ,�(�.c,� E-Mail: �/�, ,2(/�\ I/ll G�l4cct4��U c d�4cSS ,C6C.�( Town of Vail Contractor Registration =�( X �� �� ', Signature (required) Revised ADDITIONAL Valuations (Labor 8� Materials) (DO NOT include original valuation) Building$ Plumbing$ (Use additional sheet if necessary) Electrical$ Mechanical$ ' ._.._ v.._, ... .� .._ ____ �, Fire Sprinkler/Alarm$ Date Received: �I �'� � `=' `_'� � � � �� � ��� i To�� � �i NOV 0 6 2008 ' � � �� _ _ _ ! TOWN OF VAIL !. ' �,.,;�,���Et.�,.n.J11:1,:\ri�iiie�i�t FRITZLEN PIERC� ARCHITECTS �: VViili<iitt F. !'ii�ri:ir,!tr;lti!t�Cf i � T��snn Ck�ariluii,C)irc+.t��r:�f:�rchitcr.turc VAII,COLORADO i f�afhv hlc-clii��;a.(.'3fii�:����•I�u��ger ! �0�-G�1�. '�I ;i November 13, 2008 � lM � \Y� � il D �� Chris Gunion, Building Plans Examiner N�� � 4 ���8 'I Department of Community Development ;� Town of Vail Music Festival ;j 75 S. Frontage Rd. T'�WN �� VA�� Vail, CO 81657 �°�• �� Re: Plan Review Comments (based on plans submitted 11/06/08) �i Building Permit# 608-0072 '� �'� 2886ridge Street ;; ,; Chris, '�� Thanks for the opportunity to review your comments, above referenced,with you and Martin 'I this morning. Attached are responses and revisions to the plans per our discussions. Our responses to !li your comments are in red lettering following your comment '! The plan revisions include responses to comments from Rachel Friede, dated 11/10/08. ; Please note that per our discussion this morning we are still considering options for repr�oofing the existing roof surfaces that remain,the tower and Unit R-3. We will make a selection of roofing products based on roof slope,Class A rating, and existing construction of these toofs. We will make a lication to Desi n Review fo I approval of the products selected. , PP 8 Pleas ntact rr� you ve any questions. '� � li '.I e$ S� I Pierce, Archii Town of Vail �''I OFFICE COPY �' , , �� . �� FRI7'ZLEN 1Ei:iU Falln�lre*Rc�atl.��.,iti.('..�, �;i P I E R C E �%,ril,C�?l::iaiic t3i i�" p; �)7ii.-�%'b.G:i1"} C: �i-....i.;:�.-.Eii��� �I (:: i!�to(:>>vail.uchitr:c„•.c:am ' i; _•��.�•••• ti�tiler.,:«ilarf:hile<:ts,:n,ti i �� i I [ i . I i �I��� ����� � ;' ;� � De,aa�tment of Community Diewe�opment D � � � � � � � Building Safrty and Insp�eeribn Seivic�s I':I �s so�►,f�naye Road NOV 14 2008 'i �ai/, Cobrado 81657 '� 970-4T9 2138 TOWN OF VAIL I ! fAX 970-475 2952 www.vaik�ov.aom BUILDING SAFE7Y AND INSPECTION SERVICES PLAN REVIEW CdMMENTS: Building permit plan r+�risions submitbed ii/06/08 �I TO: Contractor/A Inn icant Archite '�� Highland Builders Bill Pierce � Mark Hallenbeck proj#0721 � FAX/Email #: mark@highlandbuiiders.com bill@vailarchite�ts.com , !; NUMBER OF PAGES: 4 '�� FROM: Chris Gunion, Building Plans Examiner � !,i DATE: 11/12/08 ' BUILDING PERMIT#: 608-0072 '�I OWNERS NAME: Jeff Selby ��I� SITE ADDRESS: 288 Bridge Street 'i I OCCUPANCY GROUP: mixed '�� TYPE OF CONSTRUCTION: VA �� ;i NUMBER OF STORIES: 3 BUILDING AREA: 10101 s.f. �� �� The documents submitted for this project dated li/06/08 have been reviewed for compliance with I, the 2003 Intemational Building Code, 2003 Intemational Residential Code, 2003 Intemational ! Mechanical Code, 2003 Intemational Fuei Gas Code, 2003 Interna�onal Plumbing Code, 2003 I Intematlonal Energy Conservation Code and 2008 National Electrical Code as modified and adopted I, by the Town of Vail. 7rie fro/%wing ao�nn�nt�w!//n�e�erl tn de addrzesse+d prio�tv i�ruanae of a buf/ding permit: For processing: • Please submit three com In ete sets of revised construction documents containing the requested ' information with al1 plan revision items clouded or otherwise identlfied Partial �lan sets or ' loose olan sheets are not aaaeal�ed. I • Please resaond in writing to each comment by marking the attached list or creating a resuonse �i letter. Indicate which qlan sheet, detail, sr�ecification, or calculation sMows the rea� � information. Please send revisions to the attention of the plans exami�er with the buildinq '; �it application number noted. . • Pl��se be sure to include on the resubmittal the engineer's or architect's"wet"stamR, signature, � reaistration number and date on the cover page of any structural calc4lations, all structurai I details and structural sheets of the plans. For commerciai or multi-family orojects all sheets of the �lans must be stam� � . ;I Please coordinate plan resubmittal with any Planning or Fire Department comments. ! ,� . I � i Include reference to ali SK detail sheets on the full size plans. Provide a section cut or other detaii reference on the appropriate plan sheet. �i See attached detail manual. SK detaiis are referenaed on Sheets Si, S2, S3, S4, and S6. 'i These plans are stamped by archifiect to reference architectural details only. ' i i 2 Include complete firestopping details for all pipes, conduits, cabies and other items penetrating fire '�, resistive assemblies. This was to be a deffered item from the o�iginal plan review and has not been ! � submitted. IBC 703 ! Contracbor will provide design installation and oertification of penetration protection by '; liaensed engineer for each penetration of inembrane assembiy. '�,i 3 Revise sheet X001 to indicate the correct occupancy type for the second floor on the code floor plans '� sheets and the code summary spreadsheet. Plans show reference to R occupancy. This space has ' changed to M occupancy. See revfi�ed sheet X001; Revised fio Business group B '''I ;, 4 Revise all exit and occupant load numbers on 2/X001 and 3/X001. Second level and first level plans i are incorrect. Coordinate with the X011 spreadsheet. IBC table 1004.1.2 � See revised sheet X001; Load number revised per X001 spreadsheet. ! ,'I 5 Revise sheet X001 to indicate the area on the adjacent north egress easement at the new exterior i exit stairway is non-buildable, or provide fire barrier at the north property line per IBC 706 and 602 � See rc.wised sheet X001; Noted as non-buildable '; ';� 6 Complete the code sumrnary on sheet A000 to indicate the mechanical, plumbing and electrical codes '!, to indicate the current codes as adopted by Town of Vail. See cover page for list of those codes. I See reviaed sheet A000 � 7 Revise sheet A200 to show the accessible route to storage room 102. IBC 1104 �, Aaoessibility not required by IBC 1104.4 exaeption i. j 8 Include construction details including handrails for new stair from retail 207 to storage 102. Clearly III! indicate on pians as new stair. IBC 1009 See revi�ed no�es on stair; Sheet A200 � ; - �� 9 Clarify note on exissting stairway into hall 10194'-9"from landing 100'level that indicates UP. See revised sheet A201 'II 10 Revise plans to show wall type identification tags on ail new walls. Multiple sheets. � ' See Revi�ed Sheets A200,A201, A202 � � 'i 11 Revise sheet A201 and A202 to clarify lines shown in the void space between this building and the I A&D building behind the gate. ' This spaoe is oocupied by emergency exit route for ABkD Buiiding per agreement between � owners of both properties. Stairs indicated are not supporbed by A&D Building ' � 12 Revise plans for the new east exterior stairway to comply with IBC 1009.5.2. '� See revised sheet 2/A704 " ���I ,i � . � . 13 Revise sheet A201 to show the accessible route to retail space 205. See Revised Sheet A201 ,� 14 Revise sheet A201 to show handrails on the stairway from Bridge Street to retail space 205. , See Revised Sheet A201 15 Revise sheet A201 to show 1 hour wall type identification tags on the mechanical shaft at the left of �, grid line 5. !; See revised wall tag and struetural referenoe, sheet A201; Reference revised wall type W9 Sheet A801 " 16 Revise A201 section reference at the existing bathroom and trash room area. Secdon reference text is not complete. I� See revised sectlon re�ferenoe, sheet A201 ' 17 Revise A201 to indicate wall type construction for the trash room walls. 1 'hour fire barrier ; cons�uction is required within 5'of the property line. IBC table 602. A parapet wall is required per '� IBC 704.11 See revised wall tag sheet A201; Referenae revised wall type W9 Sheet A801 �!, � i 18 Revise finish landing level at the exterior stair door from retaii 206. Landing shall be at the same ! elevation per IBC 1008.1.4. sheet A201 '' One inch drop to exfierior deck surfaae approved by Martin Haeberle ii/13/08 i 'i i 19 Revise A201 to ciearly dimension the east stair widths and the stairs and landings. Reference A703 j details. IBC 1009 ' See A703 for details. '� ,� 20 Revise A201 to indicate the east stair riser height and tread depths. Reference A703 details. IBC 1009 I'� See sheet A703 and A303.1 for details. 21 Revise sheet A202 finish deck elevations. The landing elevations shall be�he same as the interior floor. IBC 1008.1.4 One inch drop to exterior dedc surfaoe approved by Martin Haeberle 11/13/08 22 Coordinate location of deck adjacent to the north of the elevator sheet A202. Structural pians do not �; match. '� See r+evised structural pians sheet S3 23 Revise sheet A202 to show handrails and specify riser height and tread depths at the stairways in the I,'i rear deck spa area. ; See revised sheet A202 � '�� I� 24 Revise sheet A202 to specify stair width, riser height and tread depths at the east stair. Also �; reference appropriate stair details or sections. ; See A703 for details. ',', 25 Revise sheet A202 to indicate to provide safety glazing at all existing windows within 60"of the new i spa. IBC ch. 24 Spa is not induded in project ; 26 Show compliance with IBC 3109.4 for the spa enclosure or safety cover. Sheet A202 i Spa is not included in project ;,' 27 Revise sheet A203 to specify stair width, riser height and tread depths at tMe east stair. Also � reference appropriate stair details or sections. , See sheet A703 and A303.1 for de�ails. �� . �z,�.�. _ � 28 Revise A203 to provide a minimum 36"width at the new deck access to the existing north deck area. IBC 1003.3.4 Rebuild to current oonditlon � 29 Revise A204 to provide a secction at the roof overhang where shown at the north properly line � adjacent to elevator. This roof are has changed from the original plan. Show compliance with IBC ' 704.11 'I Roof overhang shown within property Iine.Con�acbor tio submit ItC j 30 Revise sheet A303 to indicate the proposed finish grade. II See Revised Sheet A303.1 ;� 31 Revise east elevation to correspond with the second floor deck plan. Sheet A303 shows deck railing ; to grid line G. ' Revision referenae is noted on elevation 32 Coordinate 1/A701 with the A201 floor plans at the trash room area. Plans do not match. See r+evi9ed detail i/A701 ; 33 Revise A704 handrail extension detail to comply with ANSI 117.1. The extension is �hown incorrecNy. ,; See revised der�ail 2/A704 !� 34 Revise A802 to indicate the app�opriate 1 hour roof/ceiling assembly detail. The UL details !� referenced appear to be for beams. See revised sheet A802 tor notie reference 35 Revise A802 east deck section. This detail appears to be no longer relevant. i De#ail 1/A802 is void. '! 36 Revise 6/A803 to show 1 hour assembly on the roof beam per the approprfate fire resistive assembly � listing. Detail6/A803 is revised 1�include 5/8 Inch Type X beam wrap. �i 37 Include the 1 hour roof/ceiling detail on sheet A804 construction assembly details. ��, See revised sheet A/804 38 Revise detail A807 to provide a minimum 30"parapet above the roof deck per IBC 704.11. Show the , property line location on this section. Construction may not encroach onto the adjacent properly. ! See revised detail per discussion with Martin Haeberle 11/13/08, ReFerence Sheet A807 ' and revised structural SK-20 �i 39 Reference detaii A/807 on the floor plans sheets. See sheets A201 and A703 Structural Comments: I'II 40 Coordinate second level deck north of elevator with architectural plans. Sheet S3 shows further 'I encroachment to the north properly line. I See r+evised structural plans, Sheet S3 'I 41 Coordinate roof ovefiang location with architecturai plans at the roof adjacent to the elevator where li shown at the.norlfi properly line. Encroachment onto adjacent properly is not permitted. � �, Roof ovefiang shown within properly Iine.Contracb�r bo submit TLC I i � i I� Plumbina Comments: 42 Revise plumbing plans to show the revised architectural background floor plans. ' Plans were revised. 43 Inciude a second floor core/shell plumbing plan. � !� PlumWng pipelines were revfsed and they are routed through the aeiling of the first level i now(see no�e #2) re�erNng to a riser on Pi.i where those pipes are valved and capped ' for fienar�t flnish oonttnuatlon. The 4"sanitary sewer is also routed in tl�e oei8ng of i'� � IevN and oonnected tio tl�e existing sewer riser in the shaf�. I extended the no�e #i �o ,I I I r , w indicaUe it more clearly. This is why we removed 2nd level plan. Detailed sewer routing is indMa�ed on tanant finish plans for Ritz Carlton on P2.0 plan.The general note#2 calls I, for fire rabed sealants on all piping perietratlng fire rated assembiles. I ' LNec�ankal Comments: i 44 Revise sheet M2.0 to provide smoke/fire dampers at duct penetrations into the 1 hour vertical shaft. ! � IBC 716.5.3.1 � Missing dampers added. 'i 45 Revise M3.2 where snowmelt work is shown on the adjacent nortfi properly. Encroachment on the '; adjacent property is not approved '� Snowmelt zone #9 removed. See Snowmeit schedule on Mi.i and revised Aoor plan M3.2. ',� 46 Revise mechanical plans to show the revised architectural background floor plans. I Plans revised. ; ,�i � 47 Include plans for any relocation or alteration of the existing exhaust ducts or HVAC ducts from the ' basement restaurant space that have been effected by the remodel. I All fresh air and exhaust from remodeled restaurant is now rout�ed infi�the shaf� Partial i Boi�r Room Ceiling HVAC plan on M2.0 indiptes connecdon points(see plan note #i) and a note"7 in fi capped for]oe's deli"on the pardal plan for exhaust. We added a note (see nobe #20)that the oontrac�r remodeling the restaurant shali verif'y and provide �I fire dampers on duclwork penetratlng from boiler room to 7ce's Deli if required as per i your oomment#44 i Electrical Commenis: II� 48 Revise electrical plans bo show the revised architectural background floor plans. Multiple sheets i Plans revised. �i i Piease refer bo the oover sheet for fMormatlon on resubmittin9 plans. In order to avoid delars in i�uanoe of I a pnrn�it,please chac:k�(roquastad infarmadon is included with tl�e resubmitbad pians. Ple�se submit ! revised plans ss a oomplebe set. Partlal plan r�ubmittals will not be roviewed. i � F:\cdev\CHRIS\PERMIT.COMMEM'S\BOB-0072\808-0072.revisions.DOC �I 'I . � i ; '� �I !I i i ' I 'I iI �I 'I �; 'i{i' I � B � ----.. . ;A • �. � . ��` :�._,..___-- `"'�1/Val I ._ Wall � r,. Lamp 1 60W A-19 ] 13W PLC 1 100W A-19 Wall mounted sconces for direct/indirect illumination from a fufly shieEded iight source. One piece, three-ply opal glass diffuser. Color: Black or white. Lumen A B C 1750 133/a 9'he 7'% 3 � 4-. �. `� � ��� �� � j��-- � _ ���. �/�.7-Z��-�. �� o� �� ������ �� ����� �� ���� ��� �::: ���� � � i __� $5 I�� C� L� � MC� � « NOV 14 2008 i _TOWN OF_VAIE.. � � p � � � o � � NOV 14 1008 11-14-2008 TOWN OF VAIL PLAN CHECK CONIIVIENTS - 3 DETAII.BOOK FOR 288 BRIDGE STREET DETAILS ARE REFERENCED ON SHEETS S 1, S2, S3, S4, AND S6 Town of Vatl OFF �CE COPY � nr esnRa— 1l��wsw w n.w.— ��.�...�.���. .._.. ��rLTiVOD�I�A71wr. .. $'T/�!hC MTlIM�OIAIO...... I�er�sn�crl�-- �'IIAT GIMMlL.-. ID'RM MTT NMIt _-. M�i S711UGTJ— MOIVOIW.MM�IMI....• � ,- 0 o e o � o 0 I I OIYLL�lrOXY MOIR y r If' 1 R71'6f�W Ol..�110 EMM7111i Ar vr w�v�wcn�u / I \ � . ���� • • � ^--_—tldlfA/O0TO1!NM� ..,. .___ ._�ao�ew,w a-�s coMr. _................_...._..._.a�r•o�c. ..,.,..ia awo-rw� •r•ae. --..._..__....._.......�av o,uc�a�naa+ __.�._... �xes cw e��ca nu GANIT6 r0!111�T ._.___......,r�id�e�eis T� �r w MroR�nww c--!!'eJ. �,.__...:....�.�..���" � „,„t........_._......._Yr����1 � I��MI��ItlR�� �_ ___ �,•a,rwoav re�,Nw t,.........,......... y,�IY�T3�'/0! ^�,....................�aj"R�iD M1T M�IL. `T-- ---IMS.rna�crJ �_....--�wdo co�o, �._._.............x•1Mf GIANlL ;_._.....'-•.'—,�•Tf}!hC f`T�IM�OMV —^^�....°..........,el�INY IZ'CMr rMLL _..^�,..._............�•TYR 7!�Yr11R1�OMD "'� �lY R-If M�T 1lrIL. .._...___........._br11{A�tN� .. •Y„ t ,.° �. „°"� `v't ,�'`� , i., „, i I ,�, G ' �! , .�... ,.a, � ���. _. .�.. . , �- ;_ __ ;�,y.�...,�:,:�.,::�.:.�.,_..,:��:.,�,�,,,�,�,..<,�,.,�.���..�.,�.�,,.�,.�...�e...�,�„�,.,;�,�rr. r,r.:,..y��",/,c^ _ ��. �.o�.�� 'ERMIT ZE155UANGE j �W � �\i W �d. s � M � � • ' w i�� � 1%� � `'_' ? W ,�� W �W �� � g`�� � >°� m J m M � W �� * V 4�oG �. Y V�W .tl �N V OL � u�� m m �v' 2�F" � V j � G GSTN DETA I LS �K�I 3" GONGRETE TOPPING W/ HYDRONIG TUB�NG X�" �.J. MIRA DRAIN 9800 DR,4 NAGE GOMP051TE ON TOP OF GGW-500R WATERPROOFiNG GARLISLE GGW-500 RE NFORGED HOT APPLIED L�QUID MEMBRANE 5Y5TEM NSTALLED BETWEEN THE LOWER SLAB AND SHEATH N6 GONT. MEMBRANE VERT. FOR i�" ON ALL SIDES a'4" PLYWOOD SHEATH NG �x SLEEPERS RIP TO e PER FOOT SLOPE BOND BEAM W/ 2-#4'S GONT. ITT 3511.88 � ROWS �/4" ANGHOR BOLTS • !6" O.G. 3x LEDGER .06.08 Z�++ �v N� W d. H � W � W �� pC �� W^ �/i 5�4� W >��� � � �a�� m�z m °�� 00 �� � o N � GSTN DETA I LS � LEDG�:::�: CE:��',�i;. �z ��4�� _ ,� ;,,,. SK02 GONTRAGTOR TD GOORDINATE BEARIN6 LEN6TH W/ MANUFAGTURER 2X SLEEPER • I b" O.G. 11�" GONG SLAB W/ HYDRONIG TUBING g/a"' �'LYWOOD SHEATHING 42" R-38 BATT INSUL �/a" HAT GHANNEL 5/e" TYPE 'X' GYPSUM BOARD i.��.v8 'ERMI T ?EI55UANGE Z�++ : . `"� t� = f�cc , � . W i= = �� ii� � � z W s W �� � W� � V^ �/1 O.'^o vI >m oo� W ���0 . V ��[[o..,,77,,11c � �N _OOL mmu �°� °v' � �� � o N -� GSTN DETAILS i JOIST BEARING DETAIL 5K08 3/4" s I'-O" ��O� 2X SLEEPPR • Ib" O.G. !1�" GONG SLAB W/ HYDRONIG TUBING �/a" PLYWOOD SHEATHIN6 12" R-38 BATT INSUL �/e" HAT GHANNEL (REF: STRUGT.) INDIVIDUAL WRAP BEAM 5/e" TYPE 'X' GYPSIJM BOARD i STEP �N FLOOR (WEST) 5K04 8/4• , �,-O• � T Z�++ W ��. �� s j: t!;. / ';M i���Y �i�;� � ? W � W �� � ��� � s�b � V ��� {]�'" G � '+~�� m u Z m o�i � �i 00 � N ° GSTN DETAILS SiG04 2X SLEEPER o 16" O.G. U'z" GONG SLAB W/ HYDRONIG TUBIN6 �/a" PLYWOOD SHEATHING i2" R-38 BATT INSUL �/a" HAT GHANNEL 5/a" n'PE 'X' 6YPSUM BOARD I.06.08 'ERMI T �u ��ll� �W i� : i'��Y �d �il l� � � W ,�� W ^ OC �`W'^ SX N �� V'? s m�� J ry � W �� V �� � � ��z� 00 °Q"� � ui � � N ° GSTN DETAlLS i STEP IN FLOOR {NORTH) SK05 9/4" ■ i'-O" 5�O� :?,;�,''tv i 4°fN1G csi-f.�,d��t°' 5!al." i�'�"'V�tG%!;yi..; "�" �;(�"-,�II? !1'vaa,E�l._�......IQN �f�, F';�Yr�iC�C�.C' 1 w Uc� .�>�Ci ,� :� A�..� G�f3�. �.X!� i�C;>c".A: iGh;�, .C!c.' ;'..t:� 4 ,�,i..€� �"71P��1.�� ,�4Gi,'�.,, ,.t"�rC,4T?c„�P'`!�'y �....'��.'' �ir�.!'� :��^v„�`r�,ii.��a''��u�� �`J/�s�� !�rr��': ��x ,:��Y���7i.ir�r i�`sf�i.�...�%c'i,�ct�zr' �.',=i .���t��...:'�,n.� �%;�" �-�z;��{�r°r v,, � f.:• .�. '�......��\��.: �{ }. \ i�� . �.-'"=k-,".:° _ i. _ � x,t, � ` � �r. � ' �� ��. i ` ` l, ` � ` ' } .... .. �� \i ' � % .. `�....... � ..,.�� � �3. !� . .,r" . �...� �.���� �.. �. E `, . s f� • '�:: " � �`��- � �!!� . � �.::�,... _ _ ._.y�� ..:...�...�, r�,,. T°�-�..�._ � �� ' �W w�r.ri��.... ,...�. i �°�'�.�;��� r��, ,�,7�; , ��r��� , �,�-� +r , `�'' � r.�s3ri i����a�%+r r:.� i s:t ', � .��� ,� . ` ��a � � / ��' \ �� � � i '�"�� ~ � .��� � ��f�'?,:..�,r.:°)h:ji^.,i,j r-%f ?�.P'�l..w���.�.;��:,, a� ���:�t������ � I � ..,.f. „�.. ..._,.�.,r..:�; ; � ; .. ,. , , � >._ . �... l ���� '+ I . �,..,mv....��.,�a��...�,,,���,�,�..a,�. � . Iqc:3F� t:';f?,,.,�.�,�.,,.. '�':Yt�"'.i�tE'f ;�,c ;c.,r�;.i..'�t•., ;jW. £� .�... 3 � A _____._......... .. _,.. .... Z�++ 1 H u� I�tI,: ,fi� �a �rii %...,u., � i�i i_f..,.� �;� r� ,� {�,.,,� �� �. �„�� r a � y . .. t�3.3r`� 'i p) 't' i � � � dwx+w�' � J+ 'tt iw.L�..n . \ ;�"? r e.,�.� ., ', `� "-G-��P�I c..�.:� 1'�:!i..'.,"!.,�,,!....�:; � ��.����„f,..�. SYNTFfNIG SHAKE 5/e" PLYWOOD 3" RIGID INSULATION R-38 BATT INSULATION 5/8" TYPE "X" GYf'SUM W:4L.LBrJARL7 R.S. GLULAM RE�: STRUGT i.l��i:�.i.���,: ,..,,�_.,�, i;fM.M I°r , .�l��iUF�Nc'_;.c' �,,,,,uaww....,_...,..�,...�,.�,., �� W V ����r, IM1 N W �li * �� iii �! `� 4t�1e.d, 46d � � � /� ��.�a�, F..��� 4�».yG�.�va 6.e.dp (� � � 1l v r �Vi h __Q . 1� :�.. �m >�i O�: ^d L' d,.. j r. �'i� �C J ,. ;V _' - Q, � J; Z�- K7 ;� G��iN *'JE'"fA�.IL.� �r-� � � �?,..r✓G� ?��"" v c°i�c.Ni C'1� �°tin-r ,'i _ i c� ���1,,,,/ � �_�' � I -Y2" DIA. EPDXY `'� A AI/��OR EAGH END I I/2" 4 I/2" ELE\/?�TI ON `F� � 1 � ._ „_,..,. __,�_ ._ . ... .� y _". ._...... Q.}� ...' � 1�i� ._--- � 3� �\� NO SGALE 2�� SEGTI ON � I �� � i.�>�:,.JB ,,_ EF:MIT �15C-aUAhlGE r -- �°.--- -- _ 2 7� .. � J u � �'� I F-W t��'v � j �d ii1'° � `' W �� � `��, � !-� ;"" � � �° ,� ,a, m_ �� w ;�o� , �✓ a- �� � �"" .� � .�...... 7`� J t� �`� J Q � m.... � � ?V �� � A 7 J 1 � �7 ��'�TRGUT ��E i t�IL� ���� 1�t,` ,�i�"�'�!`"'.,,`',..�°�� \ y*,� .:..1�s14E.�.. N.,..�?;�',' �. � � Ci'°�;.A ��.L. 1 , i� � __ � .._ _ t , �� i! � � :, ! �; � i'; , � �.i �/ 1� �,: �.I': \j a q '' . .\ 4 ; ',1 ``� '� ,� ;'} � _..�..,�;r:- r� ��. � /�i,. (u ' �^�" � 'l. ?�.'L-"�"� �r�wi�,�r / �k� •r�r ,�, ..__ E ;? � ' �� I � �� f� ...... , :�—y;°,� � �r ,.:r�:��.� � �� ...;x ;...F::"�C'?"� ,.._.�:T F� ," : . , ~°~ i � 1 w.f �.,. �:� :.__i.._ :.r'�. ; � . .. r �. - � ��V ..,,�.,�.....�mW.�.�,,,��,,�,�.�„w,,.�,.�,.�,,.�,,.,,�..�«.� �.��f:, �.. ... r '�X�an�,�•',��i'j�'i.. \ �t:y` "IG:.�J',I�:\�>,��5'f�.. § .�. .. ... .. , � J V !�; N� � F-u� �i'i � �G. IY�) �,�.� �,a,...� �..\x�.ms �, ��„•` T� �.� 1 ��� � .��� ; � a� �,,. !,�� � �� ,. �� ' S�� G� J � n �� ' ��,,� _ � c.M'�,.T� _�.�.,.`� �..., ;-,�, , �...�...'�.��_.n�..l.. � .......µ:.°`"'���.,...R��,.. i DEGK EDGE DETAIL SKIO I I/2" = I'-O" �' E.J. W/ BAGKER ROD d SEALANT 2 BUFF GOLORADO SANDSTONE, -O" EDGE BOARDER � MORTOR BED �' HYDRONIG TUBING MIRADRAIN BOARD WATERPROOFfNG RUN UP WALL MiN. 24" x^�r.: .� .4f,,,i;.,;M,_..� �'`i.... ,s,.����s 2xb SLEEP�R R?P TO SLOPE AT i'4" PER FOOT REF: STRUGT 5/8" TYPE 'X' ORYWALL W27x114 REF: STRUGT �.Ob.08 PE�.MI''" R�15�UAN�E � _._ W u ��� F � � m �W �li':� �� ii�!4 u '"'" F W � Y x Uw F.- g^ �. � �W ;� >� ;,r x W >� �a � �,•'p� � v v y x,d i 0 �N �'a U ,�n !^.✓ 9 �y S.l ? m ,�'u T_� M `�Z w U J � � � , C7EGk: DETAI L ��� � DUAL INLET DEGK DRAIN FILL AROUND DRIAN W/ PEA GRA�/EL TO PREVENT MORTAR FROM GLOGING DRAIN INLET 2" BUFF GOLORADO SANDSTONE lY2" MORTOR BED Y�" HYDRONIG TUBiNG MIRADRP�IN BOARD WATERPR�OF I NG 3�q�� PLYWOOD 2x6 SLEEPER RIP TO SLOPE AT Y4" PER FODT REF: STRUGT i DEGK DR?�IN DETAIL SK ! i/2„ _ ._�, I.v�.c�8 'E�MI T �E I�SUr�NGE Z W W V F-W °i a � �': ��1'„ i�� � ii� < l,m, v z W �. W �� C� � �N ��/\ �` ~ N V / �d' W.- �s �n W jro �':^ � � ��;�r' � �l.i J i.Vi,i X� Q,.J^ �� U 0. V -� I�/ m ,� l�vL+� �.- ? " ' Uv 7.r M QZ d�yVy �� �.�1 ~ s`J � �GK i7RAtN DETAI(.. ��� � � JOB ��`�C��r' _�` .. ��'"��iTtr�✓ 4oV�en�ineeruig'��. SFfEET I�,___ `� j" "� � � 143 e.m�Cx]ow�7riv� wife 390 F— crc�sroads snc�ng center "�,r�� • O VQH.CPSOK7dG$7({.Y7 CAICULATEf]BY��� DATE _� "f�✓'~�� 970l476-2170 Cti�CKEp BY ,__ �ATE sc�u.e �—� (S � �' �L`— ��j : ; ;� � �� ���� ...�� . : . �� ��� �� ; � ���:r� ��=� �-�'�.�.�t- . r�. r� ��' : �--�� , �, : ,i . _ : �� , � .. �� � �p �,�, :-•-� 1 ; � _ . � �� '�'�" f� , c � , : �a � c � � _ . . � a • ; ; . � � ` ;.,--�—`r�„�,,.-..... l{ � � � � �� - �`� _ � - . *�'�'''' �,�,, <� �� _t't"� 1� ..�` _...��.��- t : � c_ , , � �t"-°i ��,,, '�� �-�e y��:�� .I . � ` `� � . � t t _,-..-.--, � ����' �' ¢-.' ��r - : �r%�` � ��=�" 4 �',. � ` f t. �I.�.� �:.�-� :�� ��.,�r/,�[�� .. . fi.� , .. �i+� �'"° � °�7- 1� l4 _ # � � . , .. i _..�.. ,. ��� ��� �' O`�'1•�,icr�•/•j�'�'�.�,�•y � ` J :��I`�'!. �"��O(/ F•` __. •- .S . . 0 {�_ ) }]�y .{�}. 1• µ ` �� [ �..i/!� . n s � _ . •.e�r. F s,�V3 1"ra : . ,1. � �>.,� m: � ` .A.... .. ._� ........ .. � � ` � � .,�� � s� � � � �.� f�� - ,-� , . - ,. , , . - , � !f3 _�Y " . � � _ �: � _ 0 �: . .;,. . . . : �. �. �. .:. . . .. ..:.. . .��. 4._ ;. ) - . , �J ' � . ' /w . �V �:._ � � _ :_ :..�i�..+Y. c. � i p. . . _.. , r�, o�, ... ti. . .a i . . : ' {:� : : ... - µ .. e � �A....i. � �p ; . , . , ' p m ` ��� , � _.. e, � �� �� ., . o : _ � : � �r 4�; � �4 �,�� . � C�htr; . �� � :_ , . . . _ : _ _ �:...`�o _ �r��`�� �.��;;.�.,,,�� ���`�`�,���� ;. .� � `' t � � it . � � -- � , .... . _,.�z,. ...y ,s�":''_`._ . .._ .. .. . g" r3-.,y�'_ ed's . ._ ..,..`� -f -r, s ..5 .- -v }. c ,ir� �: .. ..'_ "' _.____ .__ ........ .. - '_. ..._.. ,. .,.�-;� P" � � � . ` , � - ,: _._. .. -�-'--- - _. �. _ �_..___ ._.--..__ -- : . ;.. . �_ - � , , _ � .,.�-: r�,3y' ..°"f _�- . ..,� . � .. -< ... -...✓ - . , . . . . . _ ' . . F �. � ..E.. . .... . : ..+ . , . � . . . : . . , . . : . . .�.-. . . : : t .... ;. .: . .f_. . _i . : .. '.. . .� ' . r� a. , '.� . . . ` - -.j,. ... . . _. ; � . � . . �' . : . .....; .... � � - . . � . _. ..y. .:. .. . .� 1 . . .: ..{. .,_ .: ..i.. . ... .. . ., .. ._ . , . . i . � . ,.. . . : _. � � i ��.,._..:>..�..� `� . : .. . _. . 'i ,� _�2 � � � . . <!f` �_ : ,. . .; , , : _� _. ` .�!►��... . � . . . ' . .. . t f�� . �� . � � � c . � .:. , .:_ _ '. .. . - . . . . . . . � �. �.... _ € . . . � . ` /� . �'. . \f , ' , . E�._ � �i_ - . � _ ... . ,. . .. �.� � � � . . .. "�x_.. _.... . . ..... . � , .. ` . . � . .-h_ . . . .. , i� v . , � . , , ' . e. . � .. . . . _ , � . .{. . . .. f. . . � �. .i.. : _ �. . �� .. . . .. y . . .. . y, . .. ` ;. .�. . . :. . _ . _ . i. � ._ :._ ; � .p. : ; , , . t , � : . .,, v. ,,- .o.. � .. . - . . : ..q. y.. ... _ ' .i.. i , ; _.. . ... . ; . �, . ..i.. . ..�.. . . .w,.. :. . .. ..- N . ... . .. . ..... .. .,F. . . ., . : . ,�..�..� � -��-::....... .....r.. .' . . �. . - . .. -� . . � . . -.i�.r..w+�u�._'..xi�--.�.y.�w.�.�.�,. r.�' .` . � . .,��. a,o+w..<�au�-+� � �� � � . ' . ��+�� . . � ' . . .. ... . . ... ..a. .... �. e� . . .x>ars��NY�.�a+w�vw�w.a. . .. ... , � ...� _�r -��+..:,�'+t �._. . �`.�` ...... �. . > . .... . ' .:.. : ,. .: . . .i- .� : . � � • , _ _. . , ,. �. ���,�� ����� : Q����nsc�r',�fi�c�`�,� `� �m:o: _;. :. , i _ _ �. d: � � �� �� r� f . ...,.- �.. q d'. .� , . . r:3 : � �� .. �. • - .�_ . e � Y�".'.. . . .4. . .. ... ' ..t. . . .,....n-�. . . .,✓^.ha-a�c.�,� , , . ._ . . � : . '� . . , % . : : . '. yJj . . � ' ` � •f��� .. �. . " . .. . . : .. ' r_. '___ . �. _.i.. .. . . ..w. ��. . . . . . � '�;���` :,. . ' ... . . . S � . ' . �. . : ,� �:,. r 4 � 308 �T'�' �IJ/�� c'"..''' �.°'��L� �._J"`i+�.�L-'�:..:.� .✓ twyre er.giru erir+�,inc. Shi�ET NO. +"'� '� OF OQ 143 e.mdGd�w cir'rve uate 390 j �j . .. crossraar,is shcK�ping t;enier CALGUtATED 6Y �� OATE_;� •-/ �°V� � sro�l,cotaracio 8'657 970(476-21]0 CHECKED 8Y___ DATE SCAI_E , �l ��� ���� �_ . s. k1�� ��� . ����¢ : � .,. ��� �� �.�.. �. ..----��--:W. �. .�_ _ � � � �_ �Y��.a.. �,� : ' : . .. . _. .�, .. : �� 3. �, .;.. .� �� . �. . � � , =�� �b�' � _ ; � , E1 �� , � __ .��-°I" -��� ��-X � }�s��x��-`" . : ,�� ��" ��� � .� � . .��.--� fi���r�.�-�.�:�- . . �,.,...�.., ,���—.�-' ��. ��- r���` _. z. � ,� �� .�_ � � . � � tt � � : . _ �._..�..�.�..._. �. : ; y���� . r " �� �� ��AN�I --'- - : ... . . .. ... ..i.. :_ �+•4'' '�:� M �}r�+. s^ . 1./„._. . �- .1 .. � � ,- �.. ��7' 4�����tt+� ��f/ � i Qa,� ;.�,,.. �.�. � �.� -t: s�- _ t � .. , . . .:. �,.. �.. _ . :. � -. . .... . � .. ........:... ....__..s. . �. � � ' �"��� .....•� ,r.' . � r+. ! n �: f i a,{��� � ;, - .aF' Q,. 5 f ^ :i ' .! ? , , � , _ _ ��` �� . � . . -::�3�SS:�'"r.. � ' <'.' 'L' � ' : ��.���. �,�l�(� ��`�"���.. �� '�� L� � i ___ F . Q .,� __ ����� � �1C,�� �a '�oYle an�inErn:i*�;�.ktc. SHfET NO.�__ 6F__ 14�e.meatlow tlrive suite 39U �-� ^j • DQ crosscor,�is stwppkig cetrter CALW LATED BY DATE�'_ U� I vt�.CUk�vcnio 81657 97014162170 ��BY DATE SCALE ; e ; �- ���4 � � �!� �1 L; _ _���tt� � �y��� ���� II � C.� ��'J,�,`�5. 4�. .%�- �1���7 � ��. �� : d�P��� - : ,__ �P�`'�� ��.��`�� �-�=..�.-���..� ' ���L� --.�.-.�..r _ , _ ��� e ��i � � . �� �L�,, � 4 � , , � � � � � �. ? , �� � �� . � _._...��..,_ ,. � p ; � � 't 5 ., � E � £ � j a F � � � E . . � � �� .� � �, : , . � _ , 7« l ' ' _ p • ��� !: � � � } `t � { � � e' f � . �.3 , �� � �1 � �� � �� _� �4 �[ �, l 3� _ - :: ' ���� i !�f." _.. � �. � �. a �f s t4 � � ts �(� ` '- ' �� t�� , f� ° I /2. ! �'z � �' - , . . . r ' �'Z '� �s � �' � ����� � �E� J� _� �0°t{ . ; �.t.�� �l`�'"��c� i.t ���`�C7 t� ,. ._._...---�.�... ; ���� � '� � , . �.,,..� , _ . . : . . �6�_t�1..� L_�1�. ���°�-- �� ��"'."�'" �l�lt,t_ j�l�LL. , . : . ��� � � M��� ., � • ,�,�`*��,����;,���,���, � . :.x � �;;ca , ���;��: 6>� .. i �. � s � ;� r�-: : _;. m, ' � 2 , ; ; ,. ....��... : _. • ;�'"� •�,..., � . � . . ... . . . � �� u F�;t� '1.�{`r��. . `��t...� � I o .� ��l ,.�.:�:� ��' � c� I t,-���;�._ I bUyie etr{�neenny.�c. SH€Ef NC7. . „�+ ` 'rJ _ OF DQ143 s.meaoow� suire 390 arossroads stwF+p�43 center �� �"� �.���_ :�� vai!,cdorndo 81657 CAi.CUlA7ED BY 6AFE__ 47Ul476-211ll CHECtCEb BYv__ DATE SGAI.E . , :. ; ; � . : �t ' �1^� �� X�� ...�—` �� �.►-�t� �-�` ---�. ,�� ; , r'� � ,� _. . . ..._ .... '. _.._ ...; . . . ..�.�..:.,, '. . w�w �!"'^.,'"". ^«.'.°..,�' .'a,"-.`.�,..,.�..._� _�. , � ', '-Sr . .. � ��� � s . �- � a p � _ . .. � ... � .j�� �� . . . : _ �1Y � � f � � , �.�"""".� , . _. , ��� � � i � }� �;,,( =-� .�- � ; '- �..� �°�`�"� � i ��`=��:�- . � :� �� ' ;; ; .. �.�,�.�.�...�..�_. - _ �._ � � ..o ..�., � t ; i � t �.i ''�j 4" � � , ; � i E,, � ��� � T � � � g� � _._� � f � .vf���.. � � �- ��� =� 1��. ., � ��� �.�..� _`��.�.,.��y...Y.y.�. _ � f _.___ � � r ' � y s.. �. . ��_ t �'°----�—^ � � �� ��- =�L(,�P-�� �,�'� : ��'�� �'.�... �::[,�.�=�� ��.� _ —_ .a.� .. _ . .�.�...�,�.. . �.� � �� � . �- , �-������:: �{��� ����l�fl : ����� d ; � . �; . . -� .<. .�. .. . : . ��,�4�'� c���!"�y � ' ����@�`�.} � ���l�w�rf� . - � � "I'� ..�`.S s . . .. _ . .. . � �,, .( y : � 6 . .. . . i 77' ��. d �,.-.a :. . ..: . � ii... .. .. .. .. � ,�,.. R'eses�s . . ' . . � . . - ������ � .�a __ ��-� �'�i� -�i� "�" �it 1 Ll���r DoYle t:n�nder�9,inc, 5HEET N0. �T!�"" �(T OF _ DOt43 e.meadow dtive wite 3A� /'►�+�)� y> aossro�s s�+opping cerAer CALCt!lATE➢8Y_ _ YfJ DATE � �s` � � v� va�,cobraGo 91657 470/47a2170 ���p gY DATE � V� ��! S�ALE �+►" � � `-� G/ : ;. . ;. :_ f � ' i : ; :._. ;_ : . _ ,_ ......__._ / _._. _ , ' i. ; ` .a. -..�.. ' � . _. ... � .;_ I .;. .; � .:;. . ._. �.._.._� ' .. f �� �. �..:�r�...�.+ j � ,., � � k, �.. � �'.7 � ��CO �` � '���.. �� � ? f .�C:+ ` :.. � �f_ _ ; � . ���- k9 �t�z-(�L; �?-t,�t �1�z��I � ' fZ 3_ ;. ` ; -_ _. , : ; ; � � ' 4 �� °_ 2 ��u3s ��`5 �� �� � !� -� ' � � , �Z �r�:��, � :�c�s z��� C�2� ��c,; �� D �,� . � , , : _ � ; �-�-1��: �u:7� : � C���� t � } � � r� �����'r�V . :. .. _P. . .. ._ .. . ... , � .. .:. .. ' .:. . ..:. �: ' . - . . o�G-�C�"�,v �_ `� _ . . . . � ; ::.. . . ; .._; . .... -_.. :. .. . �. ... .i.. .. .�_.... ...�.�. ..:. .. �. .;. : . � _ ._ .i.._ _ . . .'t.... . . f.. � . . . . . . . . . . ,i.: ' . . .. . . ,2.... .. _1_ . .. . . . _ : � .. . ' . . _ �7 . .. . . ._ .�.. .. �. � ' � . :. � #�ti ',, _ : . . . .. . :.. , . .. .. ;... i . �. � :{ �- . . . . . . Y• �� f 7�.,:1 . . . . ��it • L�r$q�y . t"t�' a'�zG�+K;�<s F`" u3. �:�`' ;�; r;� _ �`"° x $ ,�_ . � a .- . _ :;; � � ;. , .. � _ `�a�, �,' t �::��„°,.:�..s�-�` I � .,� �T��� �-�; �=��!l,�J(�..Y� buy�a»yineeri�,g.inc. sti�Er t�o.._ �t�""..� _ oF DQT43 e.meatlow driv5 sui?e 390 -- ' � ,� crossroads shoppfng Gen`�pr GALCULATED 8Y DATE � � �'��� v�l,c�"WOC�a BtbV7 47c71A?b-2170 CHECICEO BY 6kTE�— L� Q.�� � �- � —o� �,,....�.�.._...... . �...�.�.;��..�. �.e_ _ � __�. �.�. _.�,..�.,.�.......�..�...�.�..�.P.�-.�.. , y,-..._ ,�*�.._ ,,-.�_':.� ....�, , ' .... . . ,+'s�,^+��, . ., ... ......�...,.�..... k y... ,�.,. < .__.. .,.�-... .�..,, �....-. . . ...�`; ' _ � - .m�..,.._ ti,. .,.W.�wv�w+m" . ..,�.�v✓� _ : �. r .- �_ �:.-e--.. ... s y. .... . ..... . . t "' ,° ,�"��Z �(''� �. �(. c:3 ,� ;� �� G?� ti ' f,' f : � ♦ .,' ��� �� ���.(U�Lf �t� � � � , �,o.._..�,,,,._„__.. � � ...u.._ , r �r.� . _w:....�..� : �_ �� _ � , � . �-� ` _ _. _o.�..,.�..� � . ; ' �� �U.� ` � � , , '1 �.'- S � _� 7.�`� ��v��� �� ; �� -� . � �, ` _ � � � `�`ai�Ci:.V t �; ' . � ` � f � � . � �. ��G ; , � � ; ; �� �--� ..-=�u v �.�` : ; � �Z, . , f � _ -�'a� ��,-�,�j =� � -`' _ _ � � ; � ;' 2�a � � ��'��Z ` � � �� �' oc�., 3 ° f � -� lr�-�l� L�� ` �� ' ; _ �c�s�t � `�. � ��G-�'�v�.���.:.._.� _ : .. � . _ ; � , _ _ _. � : . . : � . , �''`�� � '� ��£'�' ; c��-,g•�iacri.v�z?•,o�'� o�t�` �°'° � .,E . ' <-�,: , : , . � a. , e ..� .,,� .: .. . .;. �`�.,t.` *.s� o J� �� l ���= ��'" �...t,l� L111,c�; �, �. boVkr anytnebring,��c:. SH�EY NO `� �'c_�% p� t43 e.meotlow dm�e suK�39t3 • oQ ctossoa�3s shcip�ir�cenf9r CALCULA7'ED BY .�. DkTE �r�/ 1 r�c':/ va�coswcirJU 8165) 470l476-2 i M, CWECtCED 8X_.., DAT€ SCALE � � . � }���X �t�' .Xo�t� ��L� ; . 3- ��-���v �a�'.� _ �P�t� L��:� . ►�. � ��- ��� , , _ � t��i� ' _,r . . . _ ��=. - ; � �, _�... 4� ,,�_ _ _ �. _I�. r (73/���''�'�� �� �-�. �, �- -.�.'� �.:� , �� . ��� -� -. --�� � � _.;.,� { ._. ��� �tr _�_�..� .�,.� - � ���� � �-�::-� � ���° (� �'!z`� � �� 3r��, 3 J � � , . /� . ���- x l� �� �. L.; __ �.. .�-�,,,, ���� � � �t l- � � � ��"t''a , ���tit �t�� ���� `� �-�`f��-�� . � .�.:A.:�`' . ,.. �f� .� I.... �� . ; .. . � � ;. . ��.r��i�i�,� �- " �. f�� � . . . ; .. . _ . , .��' �S1a `at"`t+�ro�( ^ �.t � n(� ��� . . _ . . . .t.. .�t t� . , ... . . . . ..... . ,�a ,. , . ; ... . � - . �. . ��R'� . � �<� . . ' ' ' � . �:.� , I , i I 9 •�� �� . .........._.. � 1 i � :3--: `3 � �! � � * � � � � � � � �4' , `h �� � �"'�.'" � . A � / . . / i \ � � � ' � 1 / , � r � ♦ .. , . ? E + �\ l � . � / � \ t,, ' I �� y / � r !' - � %� 1 � � ` � y ; r t.' f/ / � •�1 _ �- � ` � �C = � � , � �� ��-4��,__ . T. �{,�� U C71�.� txiYie eng�eering.inc. SHEET ND. j�� G OF.� • 143 e.mP.t�dow�r�e state 39Q ,. «.y Qd �''��/( ...��,,� crossroa�is shoFF�9 center CALCULATED BY �.!—�� ..._.___ DATE ��!' J,. �� �� Va+7.C01QfOdQ 6)C:17 97D/47b2170 GHECKED BY - pAT'E SCALE I �' I I . , , r �; :-��f����� �vu�c.-� f���x°�i� �.-�`—t ��"� � �„�� � a: � ; � ` . ' � t `� --� �-� (�'i.__ �., , : �t ` n� , . ���.u�.�,.���,, ,�r. ��z " � " - : ... 2 � �.,,��,�y�, '�-- _ �,, _,,, ... . � , ` . .w y j,.. . .. ...�. <. � �<e : :.. �'?�4'xt��--�� ���- � . � — �� "� x �? �' ;:,��.:> �' t�� ��: !��� ��-�" '�� t �'�+rJt':'" t/L.�'�"! d �"^f'` � }� �s w�(. ,�c :<r ..�,. ,�,,,� �".�r �. ��-��_�r..� �-- � . , _ : _ �'`� :� �--'�`'`'"" ��C'l s�'{� �:.�F��� �E"�1 1'�`' . r1 � ` � ���'��'��� � —����-?�� Y�. ,�-�L : : . . , : � . , �- ��-���-��-�t� ` , . . a .. . .. ?� �� .. U-� C� � ;_ . � : Z .. . _ �'�u�,,; x ��+G��. ` : ; ,._ �_ �� �r �_ , ._ � _ � �; . _ ,�..��. : _ : �, a a _ � ��t� ; , �tt _ ; ; ; �?' lf; � ... 4, ,� ._., � _ . 1 iL', T ,�C . _ ��Y�� i � .���: $�,., , t� �;;,t-�,�,�`a���� �:: . �:< �: . � . .. .._..... � ... �-, >r :.. .r` �. J >;a :. J./� .� ! � � �. � - �� : :.�� -� x �. . . . ......_.._. . ... _ � ' . i . � - - �� ' ..._ s� ` . � ,r� . �� � T : a . y,� � . .. . . . . . .,. �,.1"'`��. . � .� � t��'� ����:;:�.=�` ��r-�'—� bovte ang�neanng.�c sr1EE7 n1o. � � `"___�� � � 143 e,meatl�w drive s��te 390 / � � C.pss,�XfS 5h�p�Cehte� _-��._� �_f l_�� vWi,colcrrocio 8T657 GALCULATEQ 8Y DATE 1_ 97G(et78-2i 7Q CNEpcEO BY,..� DA7E _,, SCAI_E �- ; �_,. ��,..«.�.e,.w � Lry-. , � � , '� _. � /�'�'�:�.� , i : h �: . � j , „�,�-' �� —1—r^�•,��( � � ^ i t+ J r ~ ! ��" .�: ..,�; r .. . /. `; . .. ; ^ r � , �, �;r �� V`✓�� ': � i . �n • ' J _ . ,t-.._. ..: ,_ . .. � �, r y : . " s � .�„,., ......j�f. . ,..._ y.1..�" _rf_�,....�...�.�- • m.. �. ..,..; ..W�, . ... . � r i I � � • 3 • ; ` A ' y '.._. . �, �Z � �� � "%G � � � .�." � � ��� c., � .= �� y� `/� . �`�� .�;� � � � d , . ..� .. � ;, . .�� . : r..� _;_ "_i.2' _. . � _ , ; � r - - .----� --- , L k'� �f�,'t : a 4 �r?'��:l.t%� � � �� �`� � ,��-�. `� ��. ���. . -- _ , �...�. -�� �� � . � : � �� . G—�� �'' X � t,f��� �:1�� ��"��� : _ � '��; m�.�- L����� � ����c?�. � . . * � ov R���s � , . ,. . .:_ : ��4'�%}��-.jt�'9 o .-� F�'•:�o� „•:c��k�_ �. . . , p � , .� . . : ; � 1�49�ig ;� �� ; °� : � : t�o _ � :.. � . . .. . :_ �,F! � � . DNA�: - ,--, - - ;.: .a._:r-•-. �: . x-�<<..� ,'�,. �,.. ;:, :_..� .,�_�� r��f .�:-�;.� _� , y I .. � , ,- „ ,-.. .-. ;F.:�,- �" .. �.. ` � , �.: ,. ,._ r--- : i . � _._ __ __ . -- -._.. .•...----...-- _ , _ . � ' -�^ � -� �--___�. _._ ___..,._......_. _ ._ "� ^.. �. ....._.,._— . . � �-�_ ... __J.� �r . _ � 'c,d _, � _ , r.._. c .., �;>.x -A_;.. - � . :,.��--°��`---.. `�a-t�.-- , ; . _ .<�F:�.-��a�.,��_ ««_... ._«x ., .. -,s.. . .. . ,, . , . : �a..Y. _ �� � ! : . . : . . . . � . . ..... � 3 t., y. � �� �'"�F ��.. � § � �.,,,.,• ��°"' . : ;. � �,+-^."'- . ��i�� �,,.�-.., , ' E a ° y `°,��^' r . ,. . � s , r' ..m.......,.,. - _ .._._-v-..-�--.�......�,:..,.._.�..,._,«.. e . ......._..- .«.�,.,....,. ... ..,.... , ...--.,.,...-.._.. -...d- ,... .. . g ` . _ _ , _ _..,,_ .w..,,,e,,..,,. . . : . .r . . .. .. .. . � � 1 . <. � . : � �- ' � . . ': .. ... . ._.�:�. � j�; . . .. ;. .. ..j... �Y . C.. . , r r . �.. . . .�.. � . v ' .., eiC � j .r . . ��. . � .,��1�•' '. ., � e . � 5 �' � .r�. z� ..:. .. .i.f. ` !: . ✓+ % � t .., `^-.„„ � , � : .. .' : : . -� , �.r-.. � i/~.' '�. +.—i. '^``�:... ... . ��;�^ . ...->._..»...-,.,..�,.�..,..,,,.w ..:... . .;.. � , ,._.._...-...-�� . ' ,;��- € �, f ; , .. . _ ,i F -� '. �V . _ . . .. �, ...�. „"`� .,� I f _ 1� 1, � � � � �� ' i �.4., ��� �J s°q: i �� � ,A, ; , � �. ,`. .� C./ i �—� � ......., �. �" �',� � .�'�.`.� . �'� � � � � : � -� t. , �;, ; - ,�__. ; , ..w,.,_Y-°�. - £ ' � ; . � � ,...�.,-x.—. ��7 i'� t�,�. r.. i ' � � �? , <. �� � � � . �:. _.c,.....��.u....�.:�„�,,,;,,,,..�.._ ..�, .�..,.�«,.,.., , . } � . � � , � . .. � 'a�: �� � : ' �-----^°-�,°-� ,..�� �' � :. ;. t : / ,, „„� � f � > � ` � ��,��� � ' ��ww- �...���.0 � . - . . ' , . : ,�� : ""^ :° t` ';� . . � � * . �,���i....w�4'.P^"�'' . . t , . .:.. ._.. , ..V +mf - � � , � .- : � w�� .. . . . �.. . � . . .� ��: f �I z. . .. .�.;. . ... . . � . . � , � .�; a . � . s�'f . : . ;. ' ' �'/ �. � �'°` �"` �� �� � �� :.`� �°�. �.c� ,_ ` . - _ , . �_ _.. , :.... ._, u - r. �`� -� � � : � , � � �� � � -.;���`��I � .� .-�.... r `, . { ..: . ...... . . . : � ..b.. ' . . , , . , . .:, ...... • � rt �� - . . . . , . � �,. _ . . . . � ; � . . � . � . � _ � .{. � .. .. . . . . . � � ', . . ' . �� � � . � � � '� . I ' � : � � '. '. , ,.� . , .,. . .._ _ . ..�_ . : .: ..t_ . . <. . . . . . � . . . = , . . . ... .{. . ,. , �'t�°�'�y-, �.r�� �"��:% '��, �� � ���'� � ,',�. _ �. � -� � . _�:.�.9..�:.�::.• - ; : : _ s.. , , _ � ,. .; : '�V� ; 2 ; �h� � r � a � �, s • ;. , ;. :._ ,.. � _ ;._._ :... . ;�a ,g� � "� �F � a � z ,�` �-.� ' . . . . � . � `,�,y s -S. { . .. . . ; � . . . . > i , � >_ ', � -i.. . ;, .� . , . .;. . ... � ; . .:. .. }. . ...... .�_ ; : ^ � � ��� `��� � � °: f y � " . � , . _ . _ £ a .. . . . . �. . . . . ., . . . .t. -�.-��i�'��a� -�a��'�-�'�. � c : £ ' _ ' . , :. : . y � . . :.. - � � . "�--q-$� aaer���, ,�. �„ : €�;x�`3 -. � . . , .. . . . � . . ;. : .{. " ` �� x � _ . . � � . . � � '. . . . .. . - . �. . . . ' ... . _.. ����5. � T. . ..� • , . - ' • . � �m..,.a�+�� -,d++•taaeiaawwAwan�m�.,oa�usx��' - .,.:�.a.,�-> .:�.:�.:. � ..:....:. :-.... :.,�,..:... _.e..__ ...... ...._.... ..�...wc�,00,c-:,,._c.a..—P- .a....::c,Jv._.wzeL. �es� ❑ .,oe ���'�f�-'��L— �� G���y l ..'"--� -{--'� �-- _ f - boyb ang�neerirp,inc SHEET NO. --'�^°,••` [ � � Of • DQ !Q3 e meatlow�?ve wi!B 390 _ _ -" cr04srwx�s Sho(�i�8 Ct�h`er ✓�..� � r vail,caiOrodo 8#657 ��'��T�D 8Y �� -� pATE c 97�Jd�a-2174 CHECKED BY__ QATE SCALE F � j /;- ��.....«..T--��„r `""�Mw�' ,.. • .: . ; . . < ��f�'�^�:�..� �„ �-''�„r„°'��,...•?�.�.-- :. ; ��.r`-� . ,�.� -:r ,,......,.,, . . ..,--�"�".: -^'�. -�°".-" ,/� �t'" 1 �,✓.`�; > � _ �G��<.'r �� � e , � r _ �= � � �� :; J�� . ...�---.�....,�- �' � _-t._- t ,� � . �r �-+`� �" �. � .. � , ;. �. . : � h ' � � _r ; ., . � + P � ; # = �r , . � : � _ �_,�-�— � �- ��-�. ;' ! �" ,� . �. � { : a ; � � � + � , ���. �,�.,.a.�.,�-._n.� _�,�......_.�...._... ,: .�W._.,... w, ,� _. ..._ . ; v� 1 �� ; 3 � � r , f � ." � k E ' � ' ' �� � ,... ,� � � �� � � � � -�.,����� �, � . . � + � �. t ' ...�~- �,r f i � �j � , , �• � ? • � �'r: F_,�.: C ti } . y'.- j:'� ! ° � .� f t? � �, „ �+ , i s� r� � � � . i � ,�„-., .rr . r --. ,,.-• ...�!��.�� � C�� �...✓ �. }i� . V . �M1 ; .� ' .i �L�-.!""w-�"� �:.J. � � .�-3- . . .. � . � ��' . � , � � °� r �. . €._ .M. -+ . � ._.� ... �„ ...,.. . ,::+,_,,.,r..,,,„ �� � ' .. <.,.«...b--»�-_._.:-.........,�,_.....«..,.....f.:..,::,.«-.... ` ` ���. ., . .. .... ...�:..�...�r .. _. . ». _ . � ,. -., ..: a .�i . . :. r. .� �.. , f i .... _ . __ . . .. . . -. -+h...._,.....<...-.. .. ...<..+..- �k 3 S� j t. � ; �_ � � �`' j �� � r�� ��..- '?C ?" � _ "'' ' � . � � � . � ��. ��� � � ;. ��=�-� ��� �:� , , � j _ � ` , ; ,.. �' ; < , : i i ; . ; � ' �`''� � �`' �� _:��'�r �, ��� f� �.. r.. � > , ' d� :��� ... , : . .;. . .._. , .... . . . , ¢ .. ,��R��f� , : , e ���,....� l,cr� �•�,�,y e�1CMq��..��,� •.; t,a ;�Z` @. . O; ;� 14965 �: . . . � .. .:<<,,`'� : ; ? . ������� . �$�����.. _ � _ _ _ � . .,. . . -��? . � '� . t ! }`'�' . .Y 'srS� "y""�� ��:^^�fr 'i.,,;,_�� �,-r""'!' � �L .L (;. '°'�. _I�. �� . „�.....�...� ... , ... �_...�,�.�._,.-,,.r--., - .�_w,.��,..� . -_..�,�-_-......_...._ . ,,,,.>_o..�,.. _- _ ,.�.,.,..a,m.�-.. _ .,— _._.� , p ,,oe.���.i�.%��.�,'i::� �t: �'-�:.-. �"�C,.�:?�� Do�Ae snek�eering,ir�. SHEE7 NO._ --^'--'°''°:'`:� OF j ! y Q 1 A3 e,rneaciaw ci�ve suiFe 340 �-,- 1 D orosuc�cx�snoPF�+B cer•tar CALCULATED BY ;YL�_�,� DAT� `� t " � � vaN.�o!oratfa 81657 - 47pt47�2?70 CHECKED 8Y . DATE _, SGALE ���.-±-"' f , ' ' �i.�� =i"i,_�`,s�c';,� �x��..;� � ,�„„ .. ""`, � �, : . : ��::�'�r._.� ��,� � �� � . s; r ;� ��;— �.. �� � _ '` . ����� , . ; _,.� � _��. _ : ._�.�. . : , _ . _ �.,__,�A..;.;.. .r_,. , �. _ ,__ � .�: __... _�,..� __. ._ ..��_ � rv#� , _�..:. � �► # � , �__ , ' � � ," ' � - . � - � � , �, �� � ���� �� _ � �� . � �. � . �.,� �.....� a - . � ' ' -_,.-- . - 2-�.� , F �� �_._ � � � ,�.-- , �' �,{`� � 1.-� f f'� .�� m . .� t � � 'y' ,'� ,�,�'' � ��'"��- `�i '-r -' } ; � , 9 . � : , ,- � , ,. _ , r t j �� ` � �� �. b � t _. : �. , �, � � � L�_1"� � � t i�-_�~ � � x� � �'� .-..--�,� '' t � t.� �' �,.�` �,�„f�-�-�''' �I F��,� ��_ E � ; , ; , j ' -, �', �� �,�':� ��'�-�^a,..;� � � ! �'�'�`��� �� � � ,� � : ����� ��- � .�c:�'.�°;::��!.� `=x�'��� � .., -• . t �- �r p�;��..-�,�.,t... �Y,,,. ����..b��" _ , . --- �y:�> . � �- � �-� /�� U,. .� ���;' � .t �*? �"�! �'": . .: ....�..�.�.._.�,..�.., . x. .... ...�..��.. _�_._.._� : , ,_ �_.._�,,,,, ��-;�?�.-_.:. ; ��� �,,:-� `'`� _ '�r�,.„,� °�*`� �..%��-�::,� � - �� , �.. � �.� �. ._ �. . ,�`�_�` ,�:�� �,�� a�„a,, � ; � s, �: � _.. . ;. -� ,�,. �e .- '-=i 6� `. y^ �. . � � �� .�� � '� , , , �° >�' : `�i�.���, �i._.# � ��" N`��4_ � *9.� �' �� =�s€�: , �; � �oe �---l���� ��..�. .' -��,;� ��, :r.. ; boyie engineenng.s,c. swEEr No__ op O 143 s •readow drive su'te 390 -�^�''� V , ; �,,, � Q crosuc�c7s fic:pping c�rt±er CALCULA7EP BY �!. �"'� ��"''� . .. "'� .'' -�•. � vo�l�do•c7ck�S i 6.57 � PATE ! � 97U?47G-?l 7U PQ4 RF��s j qtECKEO BY DATE� � ��.••��• [r � • 5CALE '� .`f.'Zy p` � •p ye'. � :' �49¢� �; a � _.�.�. . _ . ....... .._...�. . _ . .. . ,,. , . . � . '- � '•.. „ `. ..��. ��"^'�--"-t�.-5.:,-. ��`i�'��`?```,I', ��:�.,.�+ , s�ax� � - �. ..� , , !. -..�r�.� x t3� �,r�;.1r?.�� :� ;l��.'' , .-.�,�_ ���`r;� �',.� ; Y , �. � e ���� f� �� ���� �����;:. { } �.-��'�E�� r, �� t��',;.� ��°�.� .--�.�._`__ ' , �� � � . r , . _ � . .� _ � . , . � �� - �_.. .. ��_,,._. _ ._ . _,..� � �o��: .�.�.�-,. . ..,,_,....... _.. .. y �E.-�"��. �. .���,�� � ... . �' . � . i �„�,�-�.,,(��,... ,� , t , ; , . � "' ''4"`�-�'�'"� ,,f" , � � � � � l � ' , £3 .�� � _ ._ ��.�... `���a ���. .�. � � . �.----,-r„��,� �,�-.- - . ��� ' ��� �� i � , � � t � f N ; �t�.t„-- ��-r�,�=� ---�-�---� � � ��.,�.�, _., � .,�,�-.�._ �, .. F� 4 '� � �_.,.. 5 r�-- � v �� �. _ �"�:,� . � ► . � � `���'` , , � � : � "�`� _ � � , _ .��" �'�3(G� �5:. , �_�-_ ; � �� � � - — o �%-'�,,-'��=- -�--�-,.� „�,,,-- . � Jb , ' t � � -�-�--�---�,-��---- � � �a -�:� T � � � ,� � �. � � ,� � .- , 1 1' �� r-�. A ,��--�----�- _-�---�-�,- �� __�- ���`-�`��#-"` � �...�_ �.,r__.�_.e__�-�-____ :. .. . � . � �-� '` �..-�- ; . ,; . . ,. _, .� , __. ��� ,. � �" �.� ,4 , �h ic.°i��� - ', i . �. .. , . -. . . . ..f , . . . . . . . '.[.. . . . � ' . � �. . . -1, ,. f,) v' ...,.....e..,_..l..n.,,,.. ,..wmsx.x.�..vo.ww+,q.. . . . _ "'. . . � . . , ��`��.��n- ' t ......�.x ��,.-e. •,,.... ,, r:�.:.. ,. .... _ .. " �« .. f / i. � .`.... . . . { ( ��.�. _,. � . ' _ • . � ;�:.=��-"�,l��`��._�? � .�...�;.,,��`-� , � � � �� �,��--� ����, ,�.�.�:�=' �.�',.�,�.-- � , : �,-�; E`-�'y�- ��.��,�-�� ��.��� ��„ �� f .,,�,., �,,.�-. �; � � �,,, ,. , �: ( _ , „�.; ' �; r /�`3 ,�,.. 'r'�"—� ��.�, .r-� _,a � ��»,:,.'^"'"' _�,�.,t�,�.��„ � ��-.+ - '"....» .. �-<.:.. �. , . �,; , ����-�.�` �-���"''�. � ��,�`��,.�.- �'��'--�.�. �'�=� ��._ , .�:�.�_�.�� ._�.....�� �,�..�ri...m... ._ � ��,� ._r....�w:�. .�.�....�_�..� �r._r._�. , . � . . . � ����� �' - `�� �c. �,����-.-�_�.�'.� � � �JL�. �. ���"�`` F� �'�.�"'" � °� � ��`�: �k��.'"�"f ��� ; �1� r.-�...� . : ;. .�� �:.�:,� , �" � ��� �r.���—�'�:� �� X:� �t� ��� �� � �� ��' ��?�h �y�. 1� +, �„„,� �` < ,4 �,��. � �,.. �:ei"`�i(.,. �-� � s � s, �/ ;,s� �d y,,,, � ��1 C �. �f''.4/ • f j �_� .. �,.s�`4a� . l..a.���°�._;-�t,:.?.+..f� .: '�..S:.r ��r!`X � ".�+ �'� .�►a'f/"'°".t � �� ��'(� .�-~�==t��'" -��-- _ , , ,� �yle arq�me�ering,inc. SFiEEf NO. !��••': ..•� OF D T43 e.meodoW��re suife 39C _,,,,,• " M,, , � Q r�c�ss�UdS ne�ret � ,[ . _ s� .j �ir'� CALCUtATED BY ✓'�� _ DA7E ' vr�d,coiarodo B1657 47�A76-217Q GHECKED BY DA7E,_ SCAtE . ��p4 Rf��� _ k �.,�,•µ�c�'••�� T � . o .-� , � � ..�, ;,r, :o �a�� '� 149 <• � . �, ' m• . � .... _ O�� ••.....�` �'` . �;S1r��t A� �-��'�` $.�.. ,. � _- - � � L�"� �- .�.�- Y r �, � 1� �z��ti�� `, � �� ;�_,.��:.Q�;; � �� . � ___..:..: � j� ��..,�� �,���=.�.-�,�l, �,�-- ;;.�..... ��'`�� � . � ....����� �?�_.�.�.�-'� ;� ���� . ,,. 'M '.. : .. . t ., � ��`:.µ�;�',r. 3 +�,"�".._ �.-r�"� !�� ��:'~--':, , � _ . ....,w. T . � � �'`�'�"` �'�,�-�' , £� tt �, , � � � . �`'�:� ,, ,� � •--'` .��"'> ;.,,��-' ��- a' - ' -�"`:� w;`�.� �Z ��_ . , .. ... ,. � �� . � � ._er . �, ._ , 's ,.�.��.-�, ���` ��;;'.� ,`.y , � = f� � � _ ��,e,"' r .I'�""`;i��� l �} �' . ��,� �,..� . t l ' '��� r _. _ � -� ��.:! ..r, � ..�.,�: # ���j�J' (r �" _..,�.,_,,,,,_,,.....,.�.�,.�... �. _ ��.., � � �� , � .�,.. ... _ �v _ .,.,.�.t-. � ; . _ ' �5�; :�:� .. ��� � !i �� '`''�. t' yf.- .._- �i r � �4- �, � � , .,,,,� � � ��l.... �.=� .. �; _ ` . < „ .._��,�;�___.__�.... ...�_____ S 7�: � ! ��, ! f''' .� . �S : . , , . ��__,� t �,�'"�"'�a�"G r�.;. as..�r -^�. �' ���-�. ' _ , _.x_�_ . .. � -� -~' -��;�-. , _ =��..� ��.. � � �� ���`t-��-'7"" ; �--� �-�- � .►� .� .:�-K�„� ; :�:.r�``��f'�_ �`'�-',� ��=�..-` ��� ��'� 1.�; �� 1�,% ;�y--�=rt� �`��°� ,,,,_ ,� . ,�: �. < �f � � �-t�'��`� , `�{�=��:!`�' �``�'".� �� ' �� c�; �'i�..i C.�L.- �`--��'�C�� g:,�•°' �� ;' ��=-. f��"c>: -�-.�C_(�`;`i'�; ��� ��'--�" , � ' . �- -�-�- � � �'�t.�.� �'c"� '�� '� � ,�� `��,.tl�c,-�"�`� �� � r.*� � : � �"� �"-':.� � ,.. � _. ��- � ��:''"� C� `' �1-�� �'-��'�-�:�'��.� � , : , � �(����� �� � � tx�Yie ersyinrzetirmg.inc. 81��T NO._, � � ! � i O� 143 e.rnaodow drive suite 39f1 � ""-Q QO Crossropds snop�iang eenlo� CALCULATED 9Y�� PATE � ~�7! �i�s� v�_cotoraCa 816�7 ?70�476-217Q CHECKED SY D0.TE SCAL£ . �� . . pC ,� ���' ^�r�, ✓ �4" ��kc,'hi.�'�,L•.��� ' N�i'��' ��.. _ ... _ ' . . 1^ a�� . _ �° :. S"s �� � . . � . , .- �.- yi,•_-. -- ✓' • y' .. ' ... �, . . .. — c ;�:Y? �i . ��':IiP4i .?••...r�r.,..,.._,.' :. . ... ... . ,^ . .. � �� � �. � ..� �- . _.... :... , ���� � � � v D _.. ... �_.��.�;..,�..�..�w.� ' ,; ; ' � , �_.. �_ � , ,_ _ 3 •� ` 4 . . . : . , . V .,. : � i�� Y�'��°„ � -: � ,. , .- :, � �L�t Y� _ _ . � ��_ � 4 ... �"' �� I •v,'iWI� —� � � . :... �..� f � � i . ., : .. . ,�.. � . . .... � .r �,Y",. :� . �. : .,�.:. .... 4 (y k . � .`��: ;... .... .<�. �"' . ..�.. � n :.... ..... G.. � �. .�. �. . tr ' � z� t .. . . . .w.. . � �' M. .. . .... .... . ... .. ,. .. �.. . . . f ,.. .. : ..�. � �� ."'_".�` 1r°� - � . , .. . � "i -����" �� c�. � � . � ,� �c : � ,� �. �, , : : . � : , s . f , 4 � . .� _ . ����t� ±=��. �`���`� �=����=�� `"��'�?�I" c�. _ _� _.�...�.,��,.4..�_�.�.,..����....�._._Y..�.,.���r.�.�� .....�..� . � � �oB �1��" �T. �e,�.l (��� bayle engineering,inc. SHEET NO. � � + � OF 143 e.meadow drive suite 390 Ocrossroads shopping center CALCULATED BY ��� DATE �� � � '�� vail,colorado 81657 -/-�'� �`�!� �"'°j�.,. l 970/476-2170 CHECKED BY ���F"( ..�r ri 6/ DATE � " ���� � z.++ SCALE _` _ ,�-- 2 � l2 G��� W ��"�- � ���5 �����, � � ��'���� t� �r���"�. : c9 I�o �� , � : ���:t� ��� : ; �x !�� l�`��, ' . .; �` � �� _ �I �" : . �. . �� � �. . � 4 � : ; �� �. , . � � � - - � : ; � , : : i.���(� ' ' : . � �r .�_. __ � � � t ; ; ,. lp c�..� ; ���°�'. ��"1.�. �c��„�t'U � : c�.��� GNl U ��1,.1� ' ' ,� _. : ? _ ;. _ :_ �, --,.. . ____ : : � � ; , . ... .. . _;. . .. . ... . _ : ���.P�-c,�?-- ���-L�-- �__ � !:C� '�c� � _. _ _ _ _ _,.. w . �- `c �i��: ' ��t1��� _ � __ _ , __ �� � N ��'� . ,�� ,..r. � y. , �.. �����'' ; : .n:�,. � _ _ ..._ _ _ . _ ;__ : : . , - I�����°� -� , �� , ; .-.� � 1t �� 2 ' � , �. � �� , ; �- , � -����.1�E v �J ' 'f r t �: , __ �,�? ���'��' l�L. ~ E� ,�?��"�, � . � �;, �t� 'c��; � , � __ , ,_ , RE� __..... .__. _ _ ........ .. _ ��,�.q�s o�P° ►� lF9_ _ ; ' .. ` _ _ __ . ; :.__ �. o'M F' . F� `... �s.�� C�'a. �� ;. _ � o� g �o 2. ��j '' t�`C�s t,� 9�� � . � � ' .. _ _ . ; ; <. >_.._. _... ,1 ; _ _. .. _ i_ ;_ . �r '_;, �1 '�s J _°t���y _ ; ; �- — : e. , .. � 4 ; .,�c���� , __ � ., : ,. � ��� ��-t�--�� ��. F;�� ! C��t���` ���e�e�.�; �����—��— �1 � Qtas e.m�a�ow c��v� sune aao .�.��^�y /� � °–'. ;sv����u��u+��cantar CALCUtATED BV { �''-�Gt�r' .M— or,tE t�" --�� �a+.caaaa�ai�� 970j47b21?0 CHECKED BY DATE,_... SCA�E . _ .. , ����.�� ;.-"��'°�'J " ,�`��'J �Z. �� � �.t L'�-'�' � �,. ; _; �,}�- � r � , l �C �Y#�"��;, '`�:... . .__. , ` �� ' *� � �' t t ��„C',°� � � �� �' � _ _ , �-`�=L � `' � �=� ' �t ?(1�� � '`. � , � i � � t,�.y [:� � '� s �. �. y�:��2: L�'� .. t�f�"� 1-�t � l � � �� � �� t� �-��.�-�..�� �� ���`�'t� , _ ��� C���� ��, x� ��' ��c.� � � _ E� �� ''��'� � • $ r.� G � �T' �� �;���: T' � �- ..� , , . � �� �, �POO R���sr�, ��q..�{�,lcH;g����f�,. � ° / \ ` `� �4`� � �.,? �i,;� � �,�...�,,�.,�.�.�/�.....-- 65 '"'' .� • : , _ ..� ... . .... . �x2� �.� � ;! � ; � • � e.,.•. s� �� +��r��� : ���-�t� �-��� � , � , . ��t � ��'�.+"', ,r..'"�I`"L-' �!` � �•'�� � ,.� ��" p C�' ��'�G� �-�:� ' � ,'`�� , �. ,. � '��! ���' � - �� 12. ��� �_. __ _ _ � _ _ ._. - --�-- -�-�..-�._;.:�. -- -- _ -�-- _ �� �.� __,.�. �-v, � �_.,.�...���� ..-, ��t�T� .�� �� �2:x�� �t'f�'. 't`�'�: : : '��� � � �O�<�''� � C���c�' � �. ��-��� �, �� ��� _ � ����-�� y� I `��' �'� , ���s�° ��-���5' :� �- �'�:� ��1_v� �r�.=��.�- u�,c� ; C.:��� �'��� ���� . ' _��.� �1��'� � ___ . ,f � a : ��_i <<Q ❑ �� � '�.�`�e� -�' -�"�-�, � �LrJ(!Jb �,�. Goyla Anga�ind,�nc. 3HEE1'Nb.._.._ ��� ✓'f OF�. Q T43 e.meodow�iv� wiSe 39G ,! � � Crossroads shop[r,ng ce�?er L'ALCULATED BY �((�� � DA'LE.���Q_ � vc�N.Cc�tcxio C i O5'' 9?Of476 2170 CH£CKED SY____ DATE_ SCAL.E . ° -��C �� I�� �� , _ � Z� .� � , �T��... ��!-t.��i1 ��� /r�4- �� � -����T�lC�_ F�`�r�% ���'1 ! � � � . .�1 � � �-�� : -TT�£� ����,�- . � �� � �l.Tt` T"� .....,._�...W.�,.�� ,_,...�....�� ���a�t o�' .. . . -�"u-� ��'� , ��u � �t: _ . ���� �/�-�� ?�`Z"� �'' Y ������ l��� � r,� _ �� � � ��� �a� ���,s ����"►� ��� i ���`{ r , � �...... � ���� �' "('-� ��,o,��,��,��.,��o - � ..::-�,,.,��.�- ..�-� .�, ,� �,o �,..r........�-..��.,�� ._...._�.�.._ ` � .� _�,�5 5 �� � �• .. . . + °.. _ _. . � 1 � � •N��, . . � � ��L�nlr�\���� � t �� � �;.���..�"'r'�P.�� -�G{1�� . , t� - ��� �C.�t.t��'� � �.1�� ���_a�t� r ���►�J�{'� �� . ; . , : ���."�"i.�-� --�'t.c�' � -�P� : �' �:����. �o�t,lJ�t� _ '�t.�-�"� , . �. . � �.� ��- "�'�.�t'-�. I �� : e ��.� s������_ , : � . : _ ����--�� _� ��x�� 3�� . , .. _ -� ��c:�"�.".��� .� _ � :- .,o � � �_._ ��4-DGr� �'t", -��t t�t�,�.L•J� ��9���9.kM;. StlEET NO.��� OF Qt43 e.meadow drive suite 39(3 �.t, 1 i�,, cros.uoa�ts a!wppa5g c�516r CALCULATEO BY i� OATE `��` � ��c—•3 voit cao��c 8�657 - �� ,-"._'� 970l4;6217L CHECK€D BY_ „_ pA7� SCAI.E � t-L.-��•l_�L� . 1�'L-�..DS�i��!-�� 2� � � ���:� � . . � � t c r T -� : � 7 I��'�-��'��lz. 7 __. �,f'''' ���� 3� __ �:_� _�.__ _ _ ,..�.�. _ _...`...��.....�,..�.. _.�:__..� �t��{t� . ��� ��.. ��M�� •. +.J�� �. 2 / �x� �,. � ' � �'� �.. �- d � ` �-�-'a L-� �`" w'�'` ` � . , a � �r i . � � � - ,.... s=-•.._... ,.,,....,.�.......__. . .�,,..,...._ _..,• , � �` _ � t � ""'. ,,�.�.._,�.� 1�... � . ,, � _ _ �E:�cK �1� ,� ':��� � � ,�� ,�. ` ,` B�'�� � `"; r __ r� � ,� �� � � v�- ; ,� � , � � � �. � rtYy4 a �.,�"( } � �� ,, � y, . � ,� �, . �„ � ,, �r �l � � u�x, �y �.� �,�.�. � :. �� . ; � _ � � � �_ �- - �,,:�'� . _- '�t __ �`� r 1 ��� , � � ���� ,:.. � , _ � i ,�' � , r, R,,-��. �� �� �� � _ . � . �_ _��'' �l€ . . ,: , . , : _ �� S � I �I �z �►t�,��L�f . . ��� �� �� � . : .. . .. . . . ..t. . .. . .� ��.L��.��� �� L��-�c ��-� �'"���� ���'�s _ �_ � �� � .....� �- ....�..�_� v �A�� t�t u IS.�`,� � •E' �.=-,�'¢«` ' ,� � � �'��; >•��� , ���,:�`�% N, " � d' ��,. ��. s�- ._ i^n �,, N. ;1 .. x . . . . "" . ., � � ,:i " Sx, - ry s{) .'�+.a,a„j:,L}- • � ,,� �3�-'1 ]7Ci� S� �u t �.�t i� tx�yte en9ineeeki0.Ina. SNEET NO. � � G. � pp QQ743 e,maodow drire site 390 �� [D.'�� .� ^ �as�oas�v+r�p cenre� CALCtlLATED BY o�re � v�.co6orado SF6i7 970/476-2170 CHEC{C�D 8Y DATE $CA1.E � , . . , ; ; i .: . . . : �� ' . � ,� ' :� : i ` .. ..; ��_� ��� :. . -_ �,. . .. . : . . . . � . . . . ., < , . . .L : a Q� � i G'�j; V�.,/; ��� ��. � 4 - : . j i, � s'. .� x.. _ F.. .. �� . . ` ' : : i .' .. . , � . � . 0 ! . � : : . * � � .�.. ,� ...�. � j ' � � � '� � � � � . . . . � . i �. . . . . . : , . . -. , : ' : � i : : . , . . , � _� : :_. . ,... � .. . .. .. .. . .. _ ... .. .. W L.. �� ` ��:���(�:��. : . . . y ' . . / .�.. . . - .. . . ". ��' .- r �. .: ' ♦ :. ; :. : . ��.;.�_1 � . �.a�!�.T� '._�...... ..�.._... , .... ._�....y..' ' ; ; . � .��:� 4R,. �Y�Y����.��I�. .. ��. . ., . ` ' , , . � . _ - . ... ,'� � .... =. .. ... ._ _ . . r � . { . � � � . . : : � ���—`�' s , . � � ; � _ �._ _ � , _ _ , ; . € t � � : : . s � . �. _. .. . _. _ . . . , , ; � �'?�Z��.C. � .�Z�� ` ` _ :_. ` ' : - , _ . _ w_. _: ¢ . __. _ � i ; �.�c.�,�" ; _ X� �2 �c. { ; t � ; . . , v �,.:� . � � ._ � �._ :. _ .. �: - � . : ; . i ' . . � "3 �'I��� _. ; � � ; _ ; _ �.. ; _ _.� �_ : 1 . I � ; ; M _ {. _ . . ._ _. . .._ ..... � ,__.. , . > y # � � '� _ . _ i � ,w ' � . � V �- ` C '{- : � d j.� .. '- � r. /� , E . � �; y..; � e ,� . t : , . , , , f ,�' �s--�"' 1� �o . �......_ _. ,.. ... ._ r.--_--"'"' t�"�� t - , ��i. .. � a ° � � � . t . . . . . � � . .. . � '�� : , . . �. : :. , : ' �. ' . .. ,. }.. .. ,. __. . �. : - - .. .. _.:.. �... ;_. � C+.�...!..L �: � +�`. . ,.... s ._ . � { . , . . . ' ' . .. , . ' . . , : ; .: . . . < : : . _;. � � s. � � ... .: . _:- � .�.. .;. .. ..i __ _. y . _ . , .. y .... ...._: . . . . ;�� . , � , . � . . : : �. ; �L-� ��..`r"L 4 �l. '� � - � : ; . : . : _ : _ _ :. . . _ , : , � � � : : �,� �"T`i 1��� ,. , . ; � . . , _ _ , : . ; , _ . . : : ��:�i�4-�z �i� � ; , . _ _..,.� � � �-�'� N`� ' . . ,. .. . , . K.. .. e 1' ' � . G�G� /�c�i�.— � . ; '°� ��-� �-:�'t��'��i ��'. _ } ; ; � ����`' �'t , ; . , _. _._._ .._ ;_ _ . _�. _ . � �: �. ..��t� �. ; ; ; i � _ '_ _ ,._ . ` ._ :. .. _ � ,� ± _r '� . _ ' _ . ... ' ' : _ _ �Czt_LI... �;,���r ; " �' . �_. ?��. r'? 1��-�� _. _ , :- - ���"".�'"_ .��,��2 : �, 1 , ° � ��L� , � /+ � . : ; � � . . � . . . ; ; �r � ��,�'� i7��T`'� . _ . ._..:. .. + . ..�. ..� .: � . � � . . . . . Q . . ._ . .� ;. . . . � . . �. . �... .,..._... . . , � � , : �� , . 4._ ; q.��iCNqF����` ; ' ' . ' % ' ; v::� :a'+ .... .• . . ... .. ..i. � .., . : .. ... � ��,. . . . . ....�.... .. ♦ ... :- . . � . .,. ' .:... �. r •. i < .� ;,.����JJ �: . ; �. . { .. .S. F .< .. i -: .. _..;_ . ;.. �.. ._. . : .._ � .__ .. . . - .�� i _ • � i__ _ �'- . _. , 0 ; . .. . �. ._ � ...�. ._ ._.. f . �. . , ..r �... ....�,... : �F .. . . ... . . . < ... . ... .i-.. 'i'...I�r/ �� .. _ '. . .. : . '. . 4�sIGN : � , i ; _. { fi__ : ; >L :�: . � _ - ; �� : . ; � . , ;... �� �,- , : �a'�� �;�» � �:'� ��-��� , ��� ...�--- � - .. ��,���.��� I � � \, � � � 2 '� _` r,. / .� ,`� 1 � '.� � . - ( � - � ' , .� r � � ( �t 4 � \ � f j �3 . 1 , ` t � ` r ' � � ; � � � � , f / . y , .,,,..� \ � � � � � � � i / �: S) � x"% '�',�.�..� �.w+..,�,,,..�-..•�::.� � ! � r ( k , � .�� � i I I � � � � � i � � � I i 1 �-��s � { � � : i � : ''' _ „ � � 4 ; � � � �'`e. _ �,,,,�,�, ; ` ,.. - � _ , ' ' , . . � r , �. j , � , �, , ' , , _ .- ` `\ i s � j � i i5 . . . .............. . .. . ! � � ' I `€� ` r r f . _ � I — \ y � � �i � (: �i �t / � � 6 � � , ( � �>_ _a._ � _ �. �w. _. .: � . = �r- _ _ .� ...:�. .- -;__h:_.>� . � .F..; , . __ •---.___ :_ .__.� . � �' � ` -'' ,".. _...._._ , n., ,. _ _ _...___. . .... ._ . <. ._ .� ��` ' ` ,.�,.�.. . : _� ;. __.. � _;,.�; i '.,�..K'�a�t:`�v'.+^ ',. �..� . . , a . . _ _ . . _ .. - ��„. +P� �,f''� �,w.� k � s„«+'��""f�`£��5�'� ... . +^- ° d . s � . . . ,. ; . . . . . � � , r:.;.._..,...'�,.,.......,.-,�.....,...... . ..._...,..----..�...,... �--w-,,....._.-...:....,. ...,..._.....�...,,,,...« ....:.._.,...,,-�,.-:..,., _, . . _ ... € �� � . � � <. � � � `- . . � - 1. (�:. . . -. ..i... , . ..,. . � '.. �t. � � -� ; ?i. . �...,...�,,,,� . ' . .. v '. ... <a � x,i � 1 - �.� ."Y�: . � � .:i:. .t .>. .� . �.::. - . : °'i. ... - . '"'.,. . . . � .. � �,�.._.,.....,,,..--�py,�^�..d...__....�w,. .....K.,._.�....„„..��„c„ � ��,:�: . . . %'r"`�� , . : � � .; ��� . '�'S , ' �" . ( . �� . . . ; ........ _ . . .. . . � . , c . . . . . . ' . .� . � .. . .. : .. '�.' � . , . , . . ; � : . . .w..��....w-+..o...�..+».> . ., : ...:�..� . � . . . . .. n . -.t. �� . .. . I� .� �, � _ t( Y..r^k.{ �, �,,,.» � � � '��'i � �l � ��a ��� _ . 9 , ' � ��'" . ' : ( . `� ' ,. � � ...--:-- ::. (, -'�-� 1 _i%-�( �.:.. . . .:: �. n S �;i .� . . . ..... "� �''.,% , F� , v.�.Y %�i' �� � t . � � �, . l �- � ,�,.�,�.. j � :�:� � , � � ._ 1 . . �� �; > � . , � , , � _- a # . . ..., �. .......,.,.✓--...x..rw+..� .._�,m�^`Y�`�^^"+�.w�..q.+wau...�..�- «.,�>< • i � . . . . .�...�...�m,Knr•.e»�...�.. �.. . . . . ^�..-".�..."°^`w-�+^-w�....---�- .»... . . . . - . . . . . . �.�_ .._ :. . .. . :.. . f .. . .:. .: .. � A p � � . � € ..�+���. . �-`� r„ � : . . �,+� . ' -� s.. ��« � ! -"�.`� i °w�*° :.:�_.�-wK � - � �� . �� . : : . ! . _.,. ... {�';'����'„�-x��, Y� � � ,, �. � :. f.i , , : ;: ° , � '� � � � r� ,� t�� �-� >� � �.' . ;. �Y� ' � �.;-- r r , _ � � � . . .._ : ��- � `� � _ ,. _ . _ .: : _ , ���� �.=���' ���. � � �� �`� , �� � �,. — ..�.�.... . �..�wa�_ �. ��_ . . . � . . .F ' . . . . . . . . � :. . . . �'s. ... ;. : �... ... � � r F �.. :. � .. .. : >. _ � � � � � ,. ,�,. ���,. , :�� � � � , { :�-. . � , �. , ,. . ;_ > ; � , . . . . . .E. . . . . . . . 3 . ... _.. ... .. .. .. .... .... ........ ..-.. . ..__ ..�.. .... ... ...... _ .._._ . ... . ._.. . . ._._._. . �...�w..�-.e�e....,...,......>.4 "�-- �_ -° -- `� :�-�� .— � , ,.�: , :_ - - ----_ ___ , . _. _ � _ � __ _. _ - � . �: . � � .,:..: , � .. .,. _.. . . . __ -- ..� � .. �� �,�--��, � ,;� ,.��-�$... _ _ - _�, € ``�'""�;,`4�°-" � ���,_ . � ;�-, .� ,,,e. � ��������� : � <::� ___��._ m_w;...�.�.._�._..�._._�.. __. _.._�.�_���Mw��M.._cw..-..� . . � � ;. . � , � Y r. p y, ,�; � �. ,.. � � - ,. �. + : �, ...„,-�._ _.. ; ; �. �, � :� � fi! �.' : �, � _ � � ` � :. � ', „�,.,,...:�.-�.., _.�.....��. ... � y.s �..� �� ; ,� /.� ,��,.�. � � . _ � �; � _ £ ; . ...�..� ��..�A.,� .. ���` � -� � , � .�. �� �-?'"'" t �M ,.—� ;- �_. � �. � ��. � £ ..�� _ t l-=--� � �r--�r' �' `� � � �'} jj ; , � � �- ,�,:.J � � �� t _� , � ,, _..�- j k�.-��. �.,,,-�;�.� ��,c� :� ,� _ � . � : r. � _ . , � �! .. � � � � . . ; � ` � � ��� " _:.. �..�,.:..�--.�.�._.:_.....�,.:�._w..._._�...�.._.,--„�...._.:d.,..�..«...� � - . � � � ��«�.-�-..--,-»-,.«.._�,.-.�...m_.�--�,�.. x.�� .�.,,��. .�. . � s.. t r°'��"., �t �f �- �. �' ;.+:� ,�'`�� � . _ , ,. _, . .�. .,� � <-° �'%��`.,:.��',�,„,f'�. -� : . .ny .: 1� . . ! . . �j^ ,r--� , , fr:•' � L..w^ J( `4 +'�"�: �S"f t'�� m J . � _ . . � � � � � �+ � �� �/ f . t"� ` ; -. ..:.. ... . . , . . ,i... /_;� . .. . : f ,� , N . . �_. . ,.. _ . �. ., ... _�,,... 'S� !�'f' ., ; ., - � � .. . � � . `.�. ..�� ��� . . . . . ��� . �. � . . . . . . , . . . . € .,. ._ . ... . .. . < ��f�'�;`.. -��'w��� '.,�„i J�i�,. � � � �� �, ''� �'� '�,,,,f. -� �, �---..,:,...,�...»...�,.,..�—�,,....�._ ._�..a..�K.:�.�.... „ ; ;. . f, • � � ; � ,� �, ��� . . %� '�' '' i . . . . . . , _ �„Z 8 4 P��,? . ha,_.. .. � �£ 5` ' . . ,. .. � .�. . .. .. .� . . '� . .. . . � �� � � } £ _ -., . - <„- "�#„'`_�`^t E,y%!".��' L`=.,� �.:�t� �..t- �_... _.__ w � �i� _... __�_ __... ..-- _ _ A .._.._. . �.=: r ;%� • .— .�.o an,�� :F � _ .�_.-.»'.+°'"" ,fr._. °�-.--.._. ... ..___�_..__..__ .w.��- i s � •,. . ;,'r. w.�-� r � � j �.�a.,.t_ �,�< .,>.�. . ,, .��...N: �..� � :,A-K "� '°�.-^` - � ..�.,.__ :���:?�...,. � �.�f � i° ,., .,....., „ .,:'r_ A ....s::r;s.3,'' __._.,.�-_._..__._. ��� :: ' ' "— .�._..__., .-__.___._.__ ... _....._.�—____� .__ _' � ___ __ �,,. . ,,.n . . . ..,.v.«_,.,......�».- _ — ,_�.... , ._� •�_��m°'- -"„'� � � ; � � . _ . _ .. . " ' � ' ;.a,e.�..,,-.�`L,,a°'�. �_ _ . � � � �:_� y: � ..�� � � ,�� , ',,A.- ; ; � ; �, � �'°�'`" �. �r, � � _..:.�.'""�., � , 't � �`;_..-..�_ ..�..�:--� _.�.._..�...��...... _ ��= , �-�;� � � � _..;_ .�.�...�....� � � :.,r``�� _ �� ; ..� a � �''�=�,. -~�' � , . ' � ..'°� ;`� �`�" � � �_ �. , � � ° � �. �� � �`-����� ��$,.€ �`_,, .;a"�� ' _ ; : � r. . . "'�t��"�.w-:�. : ; x .-• �-* � ,, �,� � 5 �� '`� �� � �1' �.. �,,. �.''� '°''• ��; �,� �`.� a''�"°' ° -- -w° -� - ; : , . »s � . � ; . � - ._,.,, _�x. ..._. ,.._.�_._.....�... _ .........�.....a..-::..�° ` . -. s�.,�: ,..e,..:.e. . �� . � � � � ���'`•a.. . .. . .i . _. . . , . �� � ; . . . .. .! w� �. _ . } .. .. .. - � � � �F i� .,. . •r ��. �.. � . _ .. . j �w• � . ,�4[t "� Y_•, � � � i`+ . i'�:i . � . � . . � . . � � �_ , , , � �[ �-.yi� ...d 5 £ ��� � .. . _ . . : . � x: � 3. .. : .. , ' .. . �,� ' � . . . : `^*? � .. ' . �'^ ` : ` �_., ..`F �'1 �� ` . � . � �.n .. . i.r-•-.,.. . ..... _-_aru-e^�eA,�..«..-... . �y --..wbmo�y�w..-..�vyw,�+� � ? �Y� ' . . - ' + 3 � , ��,,. . . , � , t� � � , . } �` � � k � <.,r+ .�: � � :�° � � ; �,... �: ��� _ i � � � _.._. _ _' � �.�... . .�. ; 1 �.�: � _ ;., �„�,,.k.� ^ ,. ,<..T,,., ., � � `�` �"h�- � �+ � � ...�,v:H � � �_.,.,��.. �-__ - � . � � �. _.. l y,''� � £ ; �:' � �� F �� �. .... _ � � �i A� ,.'`���� �:.. � a ¢.. , i . ` _��� � �w�* i E ' _e d '> `i �• � �. .,1 „�°''j:,.� Fa {� t o�{u+> � � , �5 i °� . '�"-�....,,._.. r - ,. � , . . .. _ ;$$. rr.�.�3 $¢ � E�1p F { � ^}�,'3 � ' 3 j �3 E� �� � ' � . . ?��`.�'''..✓ � . d €�� �''�-�...�°r� ,py°`4:�.��.s� _�'�` . . $"'.,.,a. `..._.�-,. 4!`"'`'�F. ;,.r�.. . j� _ Y . . � . }: �� � � t��€ � f � � ��� , , . . � . � .. :tE , � 4.� � .. . "y.- . ; p � .�' :��t �. . '_ . . ' , " ,. .. 't -�� _'_ t ;. � . �; � : . .. _ ,� 3 �_L � � . �. ,� �� � ; ' � .�.� �. �. ; � � :._ � _. ;" - ..� . . � ,_ �� : ; , ; - _,� ��, ; t ;��; { . � ��, t���.}'.� � �_ � X :�, ��-"9'��,.� .�.� '� �::-��I w. � � , i;S t • �,,,,_�_.S'-^.`•.'�.�.�`,d_-_ •a. ,s,�«. .�".."'-' ... . :. _ . �� � �`�' �= n � ��� R E C1,�T � .�.�..w,.,.� r.�.�..,.__ _ ..o,..,- ,;..Mx ..... � ' 0. .... 4r � . `- �„ , �'' , a ` �1` '�,iGH �•.;'pF �g � � "� ��V.'v-,... Z f t: y ..�as-`�..,-y��. . ..�;a¢�;� ��,{s,.$r.. � .i �1�.��f '� i � ���p� a `B��d E ds �`�,,,F 3 s„�h €j �'t� i, a°"'ts°-i� '�.'^- :.,a°�yF , �- .-:.a �„a � ; �r �± a :�i �'�'�'`•'!$�`,y�.e? • ��y ,� -G� } �a � � °j� r" - � � ��r : , _ . _ , _� " ,�'� � i ,,*.� � �� ,�: � ` , ��;''°� t � . � ..L�yi wi .��, . t1 �S'�".,o� < < . 3 . � � s . ; : '. � '., ' E : v.� ' ' ( i � . �fq.�' i 'e<d,-�a���}{�# :: ' . ,.,-f .-.✓ � � ��� A tq ;��� ( 3'r'„9. ;�a�'.f �s£ :� . .:.-�,..,� ._�... . _'. . . . . _- . .'� :. v�.���t\l , 1 � 3� § ' : v' : .__ _.. �.�_.� �_.� � ' ' . �.. 4 � � . ,. _ . . s .. ... .... .. .r . � .. . . . . . �' .-e"��y,�e8�.� a��........ .....���"o`.�'i�"' �:..�� � €�.."`�"._..e'� . . �- .3.. .� -�, ... .. �...:+m. ._..�..«.. w.o�e„a,��..� � � . ... . . . . . ' . . . . � ' . . '. � ; � � i _ . .. : . ,� ` . ._ .-� :_ �' � .. . � . . ��� - g �. '... �� w,e i s � � � �. .--"'„�e,�¢'A" `1 �,/'�-*� ..an.a �•. :r' . .} . ,x"° �'- '°�� �1�'6� .; � � .���_�.•`� k � � ;.,�' t. f �,.�.,,,, F .s� :a� . -'�@���. ; ���'°a,�,�"°`° t � `�� 6 F ����� "� � � � _ �.�.».,.,....... —- :�,.�..,,. --. ... w,„,�..,,�,�-.�.... ��_°'-,�"-- ..a-=.1., « ��.--�.. 3 �,� . . . . �...�...,�. . .. .�..'� - � - - �,�-� ..�.�.e..i �,. ."��� .^'# ✓-.'r.��.> ,,,�� ..- .�..�_...� �.<_.�`°'.L..°� r., 1t:<: _. . _ ._._ , ...° -.....�. _ ___. _ _._ �'........4c'_. !�. _ ' „-�,_�. ., � ,_ �. .... _..,tis, ..N''__ _. _ `_�_`�__�___-- __...._""'__ __ . . .. ,.�. { _.�_. '� � � �: . >.�. . . � � ;��} 'd �3[u'IOY --� .: . .34'.' ..'y.-� . .. ._ . ,.. , j ` ; ( � � ' :: u-v^_s'h. S P��.. r:. 's.. a �'.r` �� t,s ,.� .y r". 4�:. . . t,:..Ji..d.7 k�.H`--.-- -__��......`.,_...._.._-._....._.___ JA°�._J.._�._....._.--'-_.,_.� `�1M,�,� .:�, :x-i R .v; �`-� 4' 's'o-<:?; -�:u ; : �_ SC�-s,;= ._..__..._�__—_°_----°----------_–----_-_—_ ----------.��______-- �,,,,� �:. ,,..........�..�.««..«.e.._u�. E ' �. >. � :. ` j _ ���� ;.�«-. • _ _ � , �� _ � ,;t:� :. � s � ' N �� ,w� i # � '- ..�-- � / �� �`� �'*�, �,,.�,��,�,� �° ``�� �" � .� ;,o•'"'"� �,,� � ;d � ��,;{ :"� !� r , ,<�,e '`�4 � � - . . . � . .�. ��r ... i. . � , � � ;.s•' �°;° . < .. ."� , . � �' . .- .. . �,._.. . . . � . r . � � c � � �----- �--�----�--�,,,,,,...,,,,. �-- '--�- d� � i �' . , � _ ._ , '' Y �"w�.�`r°"�.�.�-- ` � � d � i i '� �. � ; F �' E tc.'�.�. . ��+.� . 1� E , � ,�. �;;..� ��. ta. -... .. . ` � ; i . 3��� y, � / � ���� t~ � . �. �'..a�`,Y�w..$E. ; � � �a�. �'w ��w�° a/"��F . .. .. �"b "! 6.�JV-���� �a Y a '��•-•£' . i °'r � .. . . . ; .;_ .. g � E 4 � 6 ' � � � _ ��• � � . i : ..� ., 8 � } .mrx� - 1 . .�. � . . . . � .. . . g . � t E , . � �. ' .�_.� _ 4 ' i , � �.,.."`� 1 �� �"°"Sk�� d '� � _�^ r..,� , � ;.���'�t i: � ' � � ,,,�. ` °� � � - � ; ;�,�. ��� �� � -_'� `"�.� .�. � �� d�--'�"` �^°/` � � ..-w.� : , �,: �.�...�.� �y ,°� � ° � .�' ���� � � � : � }�°" �,�, � ,��:. , ��._�_ . �{ ... :�- �.��� , : � �� ���. _ ����� ,��,,, � � � f ' � �:;� � � ; � � - - � . : ,� = � �.r � � . ; , . , � � � � °:�.. '�-�_,�t� '�`�_�,o�,:` �?��.I�� �` � � t 3 � . . � � _ � 1` ` ��,}.,'T ';'.}' � �'� r°°�� � € � � � � .,.;y— � ; ,'' -�f� �,� �'; ��''�e,,�;C,� i � � •:i[✓.��:�,,;,.; �, „j �,.�! . . 4 � �:;....� t.i..tl �": � "`""'�s�.�/�: . . � .- r^��� ,. � G . . _ . . - �'. .. . _ �"�"�_ tt +`# . . - . , . . , : . . . .. . . .. . . � .. . . .. .� � 3 . . � � � ' �' . . • ; = _---• ,� ��i,r,.»�, . e � �` .5``'.� �£ !'� "�.- ."5 `��-... y,s���:�.+' ' .r....m.�.,..... � eN L°^. �.ar+'._� i .. ., ,e.s°' : �` <_..�r� �€ .x»a 3�� , � �F,� _ _ � ' 4�'`����� �--�"��' . � � _ . _ � �. ,- , � �...�-,•�;_��-�-` ; � �, � , _ _ _ _ . ` , , . . . ._ . � ; � , ; �,..� � ,..-�° � - s � � _ . . . : � � ���- �.;:� , : .���. � ... � , �--�,�,c..�. ;�. � �L-�. � . , . _ ..,�.� .. � �. : � � ....:-�..,...�..�_.._..A..�,.�..�.�_......,� ' � . � ; � ! � ; , ; . � .� . � � � {�� � .. : : .� � �.....4"� f �.' �.�.„, ���y�A,��"`4"'��.�'.��� ��� '"�`4.��'f���: ""..� ��'��• � '�.� ..;,� 5 ., 6 g E� E' t .� }�� :'- . : .. .. .f_ . _.. ..,....._ ..,,.:,.:.,.w�.,.„..w��..��f�-au....e.,.H�..e.,�.ad.�..� .. . . . ` � .. w..,..+• w, . . . � . . _ -. � . ' . . - ; ' � 3 s . . ; , : � �� . � . . . . .. . . ; . . . � 1�.: i . . . , . i � - ._ . .. � � , ; R �� , ` .t. '"d4s.. � '� �--�– `� ,� �. ( `.:J �-#�����"',�.. � .. ���,^` ��`'"' °°.�` �'°"'"�„ °. �� � � .. ; - � � 3 f ,(� y" .`."... t a ,s" „r.�„%� � � F 7`w�.' '�� '�'°,m�. . 3} $� �u- e; 3 � } �* ! Y.! ��Ld4 .e� � za.++f �,w✓ 1 � . 9 - } �` . - . � iN'Y �4.w� r,s�'°�! .�" ��°3S a�' . � .. 'yr �p itEGfsr ' .,..., F� . • �c�fi�,�cH.��,�� � c.�'�; ' �-e'� � : , ;. _ � .. : fs� m _ :o � �� . fi •....�•- � . ���,�;�;,{�i:l�' � ,,� ���!�.�� �� �l C.I:�(lJ!�� �e�a�.�- sH�r,o. � —� �_ � 143 e.meonoiw dmre sune 300 , ` ��,_._�,• a,�_� ...� � J,,, � ����� CALCULqTfD Bv � � f� �' . � CJ 970/4762170 p{��D BY pA7E 9CALE ,. , .. _ �. . _ ���Y��y � _ .. � �.� . _ .. : ' - : � i �. . � : .� : i : ' . . . .. .. ..�.. . : . : : .: '. . '. .. . :.... . � . . , i :_. ��f8 .. . . . �� #26�� . __ ; . _ . : : �:��-�'o . ; y� ,�� � : _ _. : _ _ _ i r _ :_ : _ ; : _.. ; ' ; � �. ;� . . _: _ �� _ :. . : � .a . . . _ _ , : ; ; _ : � � �I��: : . _ .,.,. , , _ ; . f :� � �1��..�" ; _ . _ _ 3`.� _ , ; �� ; ' � _ _ _I � .. _ : � �, _ , : _ I , . � �o ; __ : ; ;l j _ � �� _ � � _ : ; ; ! _ :���}- �;��'( t . .,� , � ; ,t _�; . , � ; , _ _ _ _ __ . . , : : _ . . _ _ _ , , � ; : _- _ �-����E���'"�-/�i-j~f" --�=_.��.��_ �'t,.�u1� �� :. �?'1�,� `�;�� ... _ _..........._.. �..�.. _,,,.... _..,..�.-...� ,.. . _ a , .. ,�. ._.... ;. . :� _ . "- ° ° .. s� F �,�a� �E��IF t�. .: !.� w ..••••.. _ .;.�,o,�M�"'��•,'�►a _. _ .. �' o .: _ �, k _ �i`'•t _G,� i � ...�Q �4 �� __ _ _ � � ; . . .. . . .. _ . . . . � .. -. .:.._.. .• � G,�s: .�•...� . . ! . _ . _. ' _. SSI(}!�A��� . :. '� ' , � ��.,����� ���fs�.....�.�ir..�rw o .� m �- ��� �'�. ��t Lp�� bq4se�lpineerinp.inC. SHEEF NQ -�y,�^�" G� Of ld3 e.mipdpw drNe sUR6 3Q0 y� Qaoss�odds shoPP�9�9nte� CALCULATEO BV ��"'�" DATF ��M (,,,,� �D�-� voM.Cddodo 81667 970/476�2170 CF�p�D BY p/�7� SCnLE ;.. ; . _. . �'4 .. ,_. �� � . ' .. ;� . . .� � �.. ; :._ , ; . :r . . _ .... '.. . • - E ' �,..5'������_ . _ , : : _: _ . _ L�*� , , r _. . __ , ��,�-� _ -i�k _ �� . ; � __ _ : � �� . _ . ; . '�'� ; .. -� �/ _ _ . " � , ; _. .. ' 1 ; . .. _ !.. . :. . �`°'`�..� . :... _ _ . - ��/ _ �1 _, . ,,,,,� I �°��,, �''�. � �. - �, �ltx _ � _ _ _ _ . , : �`''�..: ' ; _�, :.. "'' ,. , _ , . ; ___ .. .. _ > � . ;. ' : : �' # _ _.. ' _ ' _ .__ ' _ . . � -: ' ; . �w � : � ,w. .,... -..: : .� : _ ` _ _ _... �` /� �. �-��' _ l�r� _ _ . �� . _ L� ._ ..._ � j�,'�',`��:� �'` . ; : ._.� . ; ; �. : , , ( s��- ,� s �-�� . . :. 1 E+� ` ��.�..1� 2 - �z :NI �_ . .. . . � : ; : _ ��"� [�. ��~�.� 1� �'- `_ �c��7�'6�{ ��.h�� _ �%- _ �� R���� � . _�.._.. � - - •- � . _ _ ^ �l.o �:=r,�L,�. : .. , ,. :�, t� . �,,.....,. : .. (��y����-`�.�� .�. .. ._.. � : . � . _ � . , _ .. .. . . . . _.. . - ��� iL�r : ���D . � . . . . . _. ... _ . . ... t . ... . :.. _., .. � .....:. ; - . . . . ; .. .:.. : , . . .. . .. . .. ; �� 149H'S �: . . :�: : . ; � ; _ _;_ _ . _ _ _ , ' 9 . ;... . ..;. .. . ; M1 •i'�w.. ;. .._. .i .:..... : .. . .. . . _. . . .. '�i"S�QHAt.�-� : , . . _ . _ ; .,>� _ ; �������,�, � Town of Vail . � OFFICE COPY �o����� � Department ofCommunity Deve%pment Building Safety and Inspection Services 75 South Frontage Road �ail, Co%ado 81657 970-479-2138 FAX 970-479-2452 www.vailgov.com BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: Building permit plan revisions submitted 11/06/08 TO: Contractor/Applicant Architect Highland Builders Bill Pierce Mark Hallenbeck proj#0721 FAX/Email #: mark@highlandbuilders.com bill@vailarchitects.com NUMBER OF PAGES: 4 FROM: Chris Gunion, Building Plans Examiner DATE: 11/12/08 BUILDING PERMIT #: B08-0072 OWNERS NAME: Jeff Selby SITE ADDRESS: 288 Bridge Street OCCUPANCY GROUP: mixed TYPE OF CONSTRUCTION: VA NUMBER OF STORIES: 3 BUILDING AREA: 10101 s.f. The documents submitted for this project dated 11/06/08 have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2008 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit; For processing: . Please submit three complete sets of revised construction documents containina the requested information with all plan revision items clouded or otherwise identified. Partial ulan sets or loose plan sheets are not accepted. • Please respond in writing to each comment by marking the attached list or creating a response letter. Indicate which plan sheet, detail, specification, or calculation shows the requested information. Please send revisions to the attention of the plans examiner with the building permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet"stamp, signaturel reqistration number and date on the cover page of any structural calculations, all structural details and structural sheets of the plans. For commercial or multi-family projects all sheets of the plans must be stamped. � .�� ��' c �G��_ �'�'" �t,t 1L.17�Nr�l ��,��.�. ����. ��- ,� � � ,�a.���,� ��� �/'�1 1 O cross�ooc�shoppMsg r.en;er CALGULAT�O BY F�� DA7E��!�__��� Q vi:_c:WcxK�:io 9lf�iJ 97GJ47b-2I7Q (�iEC1C£D 8Y RRTE SGALE_....._.�..............�_.__.__ : � � �� t����:�'�-����� �'�� ��� _ �� ��.� � '' � '� �f�- �, �� � � � :, _ : � . ��,���. � �� ��� �. . � � r��- `' ��'� . � � ��,�." f _, ^�—'�^S,�,��y.y�y�.�j��j//�'� a� ��c��T �—r ' �" f/ 1�/�r . . . �. ��y���� (/�. � �� O4'l,+t!.t�Hq�'.�� - 4" �`��.� 1�,�`O � � r�h , _ :. . �,,,�-?� ; , o;_ � : ' �� �� ! � ,� � : . _ � _ , , , t _ �[���'�fi����y� �.a�� . � � � ° �� `���!'�1�(71�.... � � f ��� : 3� �� � �b �:-#f . _ , '� _ _ . , ,3 �, ��„�,� ,,, � � ' , : -,`a.� 2 �� �'' !�il��'—�, (l�1� �vl.-"�"S : : �=�� I L� �a �c.,�-�.�� I, ,,, : ; ; I �� �h�ti , _ �, ��� G��t' ��� ��FZ"�L . �t .`t'' � �L� t�.�: .c�.� � l�- `' _ , * �- ti�a � � : �.. . , _ _ , _. , ��, ��� �r � ?�. � , � � , . � �?��"���'-'��'�L� =-'J- ��t't , � �,� ����;,�,,,� _ ; ,. , ; 4 3/t�o �, `� �'�'�� , - � ���z��t�'Y' � . � ``' : _ ,` �� ����= 2� �z � � �� �,� : I� k�+��� ��.�""s � ' � �c L�" � � Please coordinate plan resubmittal with any Planning or Fire Department comments. Architectural Comments: 1 Include reference to all SK detail sheets on the full size plans. Provide a section cut or other detail reference on the appropriate plan sheet. 2 Include complete firestopping details for all pipes, conduits, cables and other items penetrating fire resistive assemblies. This was to be a deffered item from the original plan review and has not been submitted. IBC 703 3 Revise sheet X001 to indicate the correct occupancy type for the second floor on the code floor plans sheets and the code summary spreadsheet. Plans show reference to R occupancy. This space has changed to M occupancy. 4 Revise all exit and occupant load numbers on 2/X001 and 3/X001. Second level and first level plans are incorrect. Coordinate with the X011 spreadsheet. IBC table 1004.1.2 5 Revise sheet X001 to indicate the area on the adjacent north egress easement at the new exterior exit stairway is non-buildable, or provide fire barrier at the north property line per IBC 706 and 602 6 Complete the code summary on sheet A000 to indicate the mechanical, plumbing and electrical codes to indicate the current codes as adopted by Town of Vail. See cover page for list of those codes. 7 Revise sheet A200 to show the accessible route to storage room 102. IBC 1104 -- 8 Include construction details including handrails for new stair from retail 207 to storage 102. Clearly indicate on plans as new stair. IBC 1009 9 Clarify note on existing stairway into hall 101 94'-9"from landing 100' level that indicates UP. 10 Revise plans to show wall type identification tags on all new walls. Multiple sheets. il Revise sheet A201 and A202 to clarify lines shown in the void space between this building and the A&D building behind the gate. 12 Revise plans for the new east exterior stairway to comply with IBC 1009.5.2. 13 Revise sheet A201 to show the accessible route to retail space 205. 14 Revise sheet A201 to show handrails on the stairway from Bridge Street to retail space 205. 15 Revise sheet A201 to show 1 hour wall type identification tags on the mechanical shaft at the left of grid line 5. 16 Revise A201 section reference at the existing bathroom and trash room area. Section reference text is not complete. 17 Revise A201 to indicate wall type construction for the trash room walls. 1 hour fire barrier construction is required within 5'of the properry line. IBC table 602. A parapet wall is required per IBC 704.11 18 Revise finish landing level at the exterior stair door from retail 206. Landing shall be at the same elevation per IBC 1008.1.4. sheet A201 L 19 Revise A201 to clearly dimension the east stair widths and the stairs and landings. Reference A703 details. IBC 1009 20 Revise A201 to indicate the east stair riser height and tread depths. Reference A703 details. IBC 1009 21 Revise sheet A202 finish deck elevations. The landing elevations shall be the same as the interior floor. IBC 1008.1.4 22 Coordinate location of deck adjacent to the north of the elevator sheet A202. Structural plans do not match. 23 Revise sheet A202 to show handrails and specify riser height and tread depths at the stairways in the rear deck spa area. 24 Revise sheet A202 to specify stair width, riser height and tread depths at the east stair. Also reference appropriate stair details or sections. 25 Revise sheet A202 to indicate to provide safety glazing at all existing windows within 60"of the new spa. IBC ch. 24 26 Show compliance with IBC 3109.4 for the spa enclosure or safety cover. Sheet A202 27 Revise sheet A203 to specify stair width, riser height and tread depths at the east stair. Also reference appropriate stair details or sections. 28 Revise A203 to provide a minimum 36"width at the new deck access to the existing north deck area. IBC 1003.3.4 29 Revise A204 to provide a section at the roof overhang where shown at the north property line adjacent to elevator. This roof are has changed from the original plan. Show compliance with IBC 704.11 30 Revise sheet A303 to indicate the proposed finish grade. 31 Revise east elevation to correspond with the second floor deck plan. Sheet A303 shows deck railing to grid line G. 32 Coordinate 1/A701 with the A201 floor plans at the trash room area. Plans do not match. 33 Revise A704 handrail extension detai) to comply with ANSI 117.1. The extension is shown incorrectly. 34 Revise A802 to indicate the appropriate 1 hour roof/ceiling assembly detail. The UL details referenced appear to be for beams. 35 Revise A802 east deck section. This detail appears to be no longer relevant. 36 Revise 6/A803 to show 1 hour assembly on the roof beam per the appropriate fire resistive assembly listing. 37 Include the 1 hour roof/ceiling detail on sheet A804 construction assembly details. ti 38 Revise detail A807 to provide a minimum 30" parapet above the roof deck per IBC 704.11. Show the property line location on this section. Construction may not encroach onto the adjacent property. 39 Reference detail A/807 on the floor plans sheets. Structural Comments: 40 Coordinate second level deck north of elevator with architectural plans. Sheet S3 shows further encroachment to the north property line. 41 Coordinate roof overhang location with architectural plans at the roof adjacent to the elevator where shown at the north property line. Encroachment onto adjacent properry is not permitted. Plumbing Comments: 42 Revise plumbing plans to show the revised architectural background floor plans. 43 Include a second floor core/shell plumbing plan. Mechanical Comments: 44 Revise sheet M2.0 to provide smoke/fire dampers at duct penetrations into the 1 hour vertical shaft. IBC 716.5.3.1 , 45 Revise M3.2 where snowmelt work is shown on the adjacent north properly. Encroachment on the adjacent property is not approved 46 Revise mechanical plans to show the revised architectural background floor plans. 47 Include plans for any relocation or alteration of the existing exhaust ducts or HVAC ducts from the basement restaurant space that have been effected by the remodel. Electrical Comments: 48 Revise electrical plans to show the revised architectural background floor plans. Multiple sheets Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit,please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. F:\cdev\CHRIS\PERMIT'.COMMENTS\608-0072\608-0072.revisions.DOC `,-""F'`��e�,`'�,�, �r`:�„`' ' FRITZLEN PIERCE ARCHITECTS �1'illiam F Pierce,.Archit� � Tyson Dearcluf�i; Dircct„i :_� ��c.iri��ci���,� VAIL,COLORADO Kathy He>linga,Ofiice Mana�er L� � � tJ V L�, November 6, 2008 D Chris Gunnion � .: ;� �- �� ���� Building Plans Examiner Town of Vail 75 South Frontage Road ' ����� �� `��'��� ' Vail, Colorado 81567 ���,�00�2 Re: 288 Bridge Street, AKA The Rucksack Core & Shell plan clarifications Dear Chris: Enclosed please find three sets of revised and updated plans for 288 Bridge Street. We have addressed several issues including: • All possible future changes to the existing residential units have been deleted from these plans. Any future changes will be addressed in separate permit issuances if and when they occur. • All structural plans have been updated, including a series of 8 '/z x 11 sketches that have been identified on the plans. Second floor framing plans now indicate the correct final design and co nstru cti o n. • All architectural floor plans have been updated for consistency and to reflect actual conditions and include a series of 8 '/z x 11 sketches that have been identified on the plans. • All architectural elevations have been updated for consistency and to reflect actual conditions. • The site plan has been updated to reflect actual conditions. • The east stairway has been completely redesigned and is shown in plan and elevation correctly. In addition, mechanical, electrical and plumbing plans for the base building have been updated and the backgrounds updated. We have included sprinkler plans in your sets understanding that stamped copies have also been provided. Fire alarm plans are included. Rachel Friede has approved the Change to Approved Plans submitted earlier and has released us to submit this application along with applications for the several tenant finish permits. Sincerely, � , � �� Tyson Deard�ff (,71?fallridgf:Road,Suite C-1, �.ail,Coloradi�8165' I �a'O.d'b.b:i42 I� ��'O.4?6.�9p1 ! inio c�vailarc:hitects.ccim =4vw.��ailarchitects.com ARCHITECTS �-- - � C� C� C�, ���� t��� � � I COMcheck Software Version 3.5.3 '�' �'j Envelope Compliance C�ertificate _.__ �� �"o�� c�f I��rii ����J� Z 2003 IECC ������ � Report Date: 10/31/O8 r �,,��PY Data filename: P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Section 1: Project Information Project Type:Addition Project Title: Bridge Street Construction Site: Owner/Agent: Designer/Contractor: Bridge Street Jake Peterson Vail,CO 81658 AEC 40801 US Hwy 6 and 24 Suite 214 Eagle Vail,CO 81620 970-748-8520 jake@aec-vail.com Section 2: General Information Building Location(for weather data): Vail,Colorado Climate Zone: 15 Heating Degree Days(base 65 degrees F): 9248 Cooling Degree Days(base 65 degrees F): 44 Vertical Glazing/Wall Area Pct.: 10% Activitv Tvoe(s) Floor Area Retail Sales,Wholesale Showroom 4057 Office 395 Corridor,Restroom,Support Area 773 Restaurant 775 Section 3: Requirements Checklist � .: � , .- ..- Climate-Specific Requirements: Component Name/Description Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor all roof:All-Wood JoisURafter/Truss 4985 47.0 0.0 0.023 0.045 all walls:Wood Frame,Any Spacing 4327 21.0 0.0 0.062 0.064 all windows:Wood Frame:Double Pane,Clear,SHGC 0.60,PF 1.50 462 --- --- 0.360 0.520 wood doors:Solid 195 --- --- 0.300 0.108 sliding doors:Glass,Clear,SHGC 0.60,PF 1.50 250 --- --- 0.300 0.520 Basement Wall 1:Solid Concrete or Masonry>8",Furring:Wood, 2970 21.0 0.0 0.081 0.087 Wall Ht 10.0,Depth B.G.0.0 all other floors:All-Wood JoisUTruss 4843 30.0 0.0 0.033 0.040 basement floor:Slab-On-Grade:Unheated 270 --- --- --- --- (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: � 1. All joints and penetrations are caulked,gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. . --- _ ....-_ _ ___ . .... ..-. Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 1 of 6 � � � 2. Windows,doors,and skylights certified as meeting leakage requirements. � 3. Component R-values&U-factors labeled as certified. � 4. Insulation installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. � 5. Stair,elevator shaft vents,and other dampers integral to the building envelope are equipped with motorized dampers. � 6. Cargo doors and loading dock doors are weather sealed. � 7. Recessed lighting fixtures are:(i)Type IC rated and sealed or gasketed;or(ii)installed inside an appropriate air-tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. � 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq.ft.in area. � 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,specifications and other calculations submitted with this pertnit application.The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.5.3 and to comply with the mandatory requirements in the Requirements Checklist. �� J��,1��, ��"�c�'� � ���--"�(---C"��' Name-Title S' n re Date Project Notes: Addition of residential part on second floor and rising roof on retails. P F�/ ��� F �� � . .- O . r J� � �'�,� l Q 3/ .���� �SS��NAL ENG\� Project Title: Bridge Street z �� m Report date`10/31l08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 2 of 6 COMcheck Software Version 3.5.3 Mechanical Compliance Certificate 2003 IECC Report Date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Section 1: Project Information Project Type:Addition Project Title:Bridge Street Construction Site: Owner/Agent: Designer/Contractor: Bridge Street Jake Peterson Vail,CO 81658 AEC 40801 US Hwy 6 and 24 Suite 214 Eagle Vail,CO 81620 970-748-8520 jake@aec-vail.com Section 2: General Information Building Location(for weather data): Vail,Colorado Climate Zone: 15 Heating Degree Days(base 65 degrees F): 9248 Cooling Degree Days(base 65 degrees F): 44 Section 3: Mechanical Systems List n i Svstem T,y_oe 8 Descri tp ion 2 Plant 1:Heating:Hot Water Boiler,Capacity>=600 kBtu/h,Gas 2 Storage Water Heater 1:Service Water Heater w/Circulation Pump Section 4: Requirements Checklist Requirements Specific To: Plant 1 : � 1. Equipment minimum efficiency:Boiler Thermal Efficiency>=75%Et � 2. Newly purchased heating equipment meets the efficiency requirements-used equipment must meet 80%Et @ maximum capacity � 3. Systems with multiple boilers have automatic controls capable of sequencing boiler operation � 4. Hydronic heating systems comprised of a single boiler and>500 kBtu/h input design capacity include either a multistaged or modulating bumer Requirements Specific To: Storage Water Heater 1 : � 1. 1-in.pipe insulation on circulation systems � 2. Automatic on/off control required for circulating systems � 3. Gas Storage Water Heater efficiency>=0.53 EF Generic Requirements: Must be met by all systems to which the requirement is applicable: � 1. Load calculations per 2001 ASHRAE Fundamentals � 2. Plant equipment and system capacity no greater than needed to meet loads - Exception:Standby equipment automatically off when primary system is operating - Exception:Multiple units controlled to sequence operation as a function of load � 3. Hot water pipe insulation: 1 in.for pipes<=1.5 in.and 2 in.for pipes>1.5 in.Chilled water/refigeranUbrine pipe insulation:1 in.for pipes<=1.5 in.and 1.5 in.for pipes>1.5 in.Steam pipe insulation:1.5 in.for pipes<=1.5 in.and 3 in.for pipes>1.5 in. Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 3 of 6 � - Exception:Piping within HVAC equipment - Exception:Fluid temperatures between 55 and 105 degrees F - Exception:Fluid not heated or cooled - Exception:Runouts<4 ft in length � 4. Newly purchased service water heating equipment meets the efficiency requirements � 5. Water heater temperature controls:110 degrees F for dwelling units or 90 degrees F for other occupancies � 6. Hot water distribution systems>=300 kBtu/h must have one of the following:a)controls that reset supply water temperature by 25%of supply/return delta T b)mechanical or electrical adjustable-speed pump drive(s)c)two-way valves at all heating coils d)multiple-stage pumps e)other system controls that reduce pump flow by at least 50°/a based on load-calculations required Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck Version 3.5.3 and to comply with the mandatory requirements in the Requirements Checklist. �G�kQ✓ �"�VSC51/� �d—��"d�T'� Name-Title Si re Date �P�� REG�ST O..�O H(i,�,F'P G�;� Z �O • :Q 29840 � * Ys � ��. ��� �� �`SS�ONA1-E�G Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 4 of 6 � � . �- . COMcheck Software Version 3.5.3 Mechanical Requirements Description 2003 IECC Report Date: Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: Plant 1 : 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency: Boiler Thermal Efficiency>=75%Et 2. The specified heating equipment is covered by Federal minimum efficiency requirements.New equipment of this type can be assumed to meet or exceed ASHRAE 90.1 Code requirements for equipment efficiency.Used equipment must meet 80%Et @ maximum capacity. 3. Systems with multiple boilers have automatic controls capable of sequencing the operation of the boilers. 4. Hydronic heating systems comprised of a single boiler and>500 kBtu/h input design capacity include either a multistaged or modulating bumer. Requirements Specific To: Storage Water Heater 1 : 1. Piping for the specified circulating service hot water system must be insulated with a minimum of 1-in.insulation having a conductiv'ity no >0.28 Btu-in/(h-ft2-degrees F). 2. Circulating service hot water systems must have a time switch control that can automatically tum off the system during unoccupied hours. 3. Service water heating equipment used solely for heating potable water,pool heaters,and hot water storage tanks must meet the following miniumum e�ciency:Gas Storage Water Heater efficiency>=0.53 EF Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads.A single piece of equipment providing both heating and cooling must satisfy this provision for one function with the capacity for the other function as small as possible,within available equipment options. - Exception:The equipment and/or system capacity may be greater than calculated loads for standby purposes.Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. - Exception:Muttiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. All pipes serving space-conditioning systems must be insulated as follows:Hot water piping for heating systems:1 in.for pipes<=1 1/2-in.nominal diameter 2 in.for pipes>1 1/2-in.nominal diameter.Chilled water,refigerant,and brine piping systems:1 in.insulation for pipes<=1 1/2-in.nominal diameter 7 1/2 in.insulation for pipes>1 1/2-in.nominal diameter.Steam piping:1 1/2 in.insulation for pipes<=1 1/2-in.nominal diameter 3 in.insulation for pipes>1 1/2-in.nominal diameter. - Exception:Pipe insulation is not required for factory-installed piping within HVAC equipment. - Exception:Pipe insulation is not required for piping that conveys fluids having a design operating temperature range between 55 degrees F and 105 degrees F. - Exception:Pipe insulation is not required for piping that conveys fluids that have not been heated or cooled through the use of fossil fuels or electric power. - Exception:Pipe insulation is not required for runout piping not exceeding 4 ft in length and 1 in.in diameter between the control valve and HVAC coil. 4. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992,which meet or exceed ASHRAE 90.1 Code.New service water heating equipment can be assumed to meet these requirements. 5. Water-heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for dwelling units and 90 degrees F for other occupancies.Controls must limit output temperatures of lavatories in public facility restrooms to 110 degrees F. 6. Hot water space-heating systems with a capacity exceeding 300 kBtu/h supplying heated water to comfort conditioning systems must include controls that automatically reset supply water temperatures by representative building loads(including retum water temperature) Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 5 of 6 � . ` � or by outside air temperature.Exceptions:-Where the supply temperature reset controls cannot be implemented without causing improper operation of heating,coofing,humidification,or dehumidification systems.-Hydronic systems that use variable flow to reduce pumping energy. Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 6 of 6 � a " COMcheck Software Version 3.5.3 Interior Lighting Compliance Certificate 2003 IECC . Report Date: 70/31/08 Data filename: P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Section 1: Project Information Project Type:Addition Project Title:Bridge Street Construction Site: Owner/Agent: Designer/Contractor: Bridge Street Jake Peterson Vail,CO 81658 AEC 40801 US Hwy 6 and 24 Suite 214 Eagle Vail,CO 81620 970-748-8520 jake@aec-vail.com Section 2: General Information Building Use Description by: Activity Type Activitv Tvoelsl Floor Area Retail Sales,Wholesale Showroom 4057 Office 395 Corridor,ResVoom,Support Area 773 Restaurant 775 Section 3: Requirements Checklist Interior Lighting: � 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 8725 1024 YES � 2. Exit signs 5 Watts or less per side. Exterior Lighting: � 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings;signage;safety or security lighting;low-voltage landscape lighting. Controls, Switching, and Wiring: � 4. Independent controls for each space(switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. � 5. Master switch at entry to hotel/motel guest room. � 6. Individual dwelling units separately metered. � 7. Each space provided with a manual control to provide unifortn light reduction by at least 50%. Exceptions: Only one luminaire in space; Project Title: Bridge Street ��� Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 1 of 3 � An occupant-sensing device controls the area; The area is a corridor,storeroom,restroom,public lobby or guest room; Areas that use less than 0.6 Watts/sq.ft. � 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Areas with only one luminaire,corridors,storerooms,restrooms,or public lobbies. � 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. � 10.Tandem wired one-lamp and three-lamp ballasted luminaires(No single-lamp ballasts). Exceptions: Electronic high-frequency ballasts;Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2003 IECC,Chapter 8, requirements in COMcheck Version 3.5.3 and to comply with the mandatory requirements in the Requirements Checklist. G ,���,��f L�,. ,�� - �� ' �'�o � Name-Title ignature Date Project Notes: Addition of residential part on second floor and rising roof on retails. �P�p RE��Sr O�.O�O. H C/��'S� F G ;� Z � + :Q 29840 m ' . r� � ��� ��. ��SS�ONA�E�G\� Project Title: Bridge Street '�.�� Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 2 of 3 . � COMcheck Software Version 3.5.3 Interior Lighting Application Worksheet 2003 IECC Report Date: Data filename: P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/it2 (B x C) Retail Sales,Wholesale Showroom 4057 1.7 6gg7 Off� 395 1.1 435 Corridor,ResVoom,Support Area 773 0.9 696 Restaurant 775 0.9 698 Total Allowed Watts= 8725 Section 2: Proposed Lighting Power Calculation A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail S�es,Wholgsale Showroom(4057 aq.ft.) Linear Fluorescent 1:F1:48"T8 32W/Electronic 2 8 64 512 i)flioe(395.sq.R) Linear Fluorescent 1:F1:48"T8 32W/Electronic 2 1 64 64 +Corfidor.Restrnom,Support/U'#�s(773 8q.iti.) Linear Fluorescent 1:F1:48"T8 32W/Electronic 2 6 64 384 �es�aura�(r�s sy.�.) . Linear Fluorescent 1:F1:48"T8 32W/ElecVonic 2 1 64 64 Total Proposed Watts= 1024 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero,the building complies. Total Allowed Watts= 8725 Total Proposed Watts= 1024 Project Compliance= 7701 . . . Project Title: Bridge Street Report date: 10/31/08 Data filename:P:\Current Projects�27838-Bridge Street Building\Calculations\Mechanical\080228-comcheck.cck Page 3 of 3 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES . . ro�+ro�v,�u . Community Development 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2138, f. 970.479.2452, inspections 970.479.2149 ADD/ALT COMM BUILD PERMT Permit # B08-OO7Z � Project# �'1 � b � -b�3�� Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.......: RUCKSACK BUILDING Applied .. . : 04/07/2008 Parcel No....: 210108244003 Issued . . . : 05/20/2008 Expires......: 11/16/2008 OWNER ROSENQUIST,RICHARD N. - BROW 04/07/2008 -SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT HIGHLAND BUILDERS CORPORATIO 04/07/2008 Phone: (719)499-9248 � 2598 Palmer Park Blvd. Colorado Springs CO 80909 License: 208-A CONTRACTOR HIGHLAND BUILDERS CORPORATIO 04/07/2008 Phone: (719)499-9248 2598 Palmer Park Blvd. Colorado Springs CO 80909 License: 208-A Desciption: CORE AND SHELL FOR NEW SECOND FLOOR RESIDENTIAL CONDO AND GROUND FLOOR RETAIL SPACES IN THE BRIDGE STREET BUILDING (FORMER RUCKSACK) Occupancy: mixed Type Construction: VA Valuation: 1,348,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 ...«.«.......,..*..,.,.....*..*...............,.�.,�.,.......,,.......«. FEE SUMMARY ..,�...*..........«,...**.«..**...«........,........,..,,.........,......... Building Permit Fee--> $6,878.95 Will Call--------------> $4.00 TOTAL FEES---------> 511,354.27 Plan Check-----> $4,471.32 Restaurant Plan Review $0.00 Payments---------------> $11,354.27 Addl Plan Hrs---> $0.00 Recreation Fee---> $0.00 BALANCE DUE------> a0.00 Addl Plan Review $0.00 Investigation Fee--------> $0.00 *«�,..««*«...«***.,*..****...******.......«***.,.«*,.«««***«««*.*..«*.*«**«......***...*:*.**...*�*.«******.*«*..«**.*..**.....*.�.............*..*«* See the Approval and Conditions sections (following pages) of this document for any c � ions th apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an ac ate lot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comp w h all Town ordinances and state laws, and to build this structure according to the town's zoning and subdivision codes, desig review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOUR I NCE BY TELEPHON 970-479-2149 OR AT OUR OFFICE FRO 8:00 AM -4 PM. YOU MUST P OVIDE T PERMIT NUM O OBTAIN AN INSPE�TION. �� D DATE NATUR OF OWNER OR CONTRACT OR HIMSE�F AND OWNER ,.,� .,*....«.*..**......****,.*«..****..*.........,****.......*.**,...********�****.,►*,.**«*...«**��.�*****,...*«,,,,****..****....***...*.**«,.**«***..**.*�*.** APPROVALS � Permit#: B08-0072 as of 05-20-2008 Status: ISSUED *.*««�****...*.««,..*«.**********,,,,,,,,*«*�*«*«*.*.*,,,,,,,,,�*,�.«««.....***.**...,.*.**�*«**««*****.*«..*.**...**....*«**,.,..****.***«*****.....****,►,.**...*«* Permit Type: ADD/ALT COMM BUILD PERMT Applied: 04/07/2008 Applicant: HIGHLAND BUILDERS CORPORATION , Issued: 05/20/2008 (719)499-9248 To Expire: 11/16/2008 Job Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Parcel No: 210108244003 Description: CORE AND SHELL FOR NEW SECOND FLOOR RESIDENTIAL CONDO AND GROUND FLOOR RETAIL SPACES IN THE BRIDGE STREET BUILDING (FORMER RUCKSACK) •rr�,rrw*w*r,ew*****rw**r:*w*ww**wrwwww,e**:*:,+w,rr**rr,r****,r,r,rw*,►wwwtAP P rova Is•••••,,**«********...,.****�************«****.***,.****.,***......*...***..* Item: 05100 BUILDING DEPARTMENT 04/21/2008 cgunion Action: CR corrections required. sent comments to applicant and architect F:\cdev\CHRIS\PERMIT.COMMENTS\B07-0307\B07-0307.DOC 05/01/2008 cgunion Action: CR second check review comments sent F:\cdev\CHRIS\PERMIT.COMMENTS\608-0072\608-0072.secondcheckDOC.DOC 05/05/2008 cgunion Action: AP APPROVED REVISED, CORRECTED PLANS DATED 5/1/08 Item: 05400 PLANNING DEPARTMENT 04/16/2008 sdh Action: AP Approved,with additional conditions placed on issuance of permit. Item: 05600 FIRE DEPARTMENT 05/09/2008 mcgee Action: AP Fire sprinkler and fire alarm permits and plans required. Item: 05500 PUBLIC WORKS 05/13/2008 csalli Action: AP *wt**wrrwir,t**xwww#*r*t****w***w**rrwrrrwwww**w*wwerrrrrrrwww�rrr*r**w*****w*wwww**rr*rww********wrw**********wrr**ttr*rw******w#wrw*****t**rwt*****rr CONDITIONS OF APPROVAL Permit#: B08-0072 as of 05-20-2008 Status: ISSUED ..*...«..***..,,***.*..*�....****.*.........,,.*..*.,..,,*.............*«**...*........*******.*.*.»..x**..«**.*„****...**,�***,,,.,.,....,,*..******..*.*.*.. Permit Type: ADD/ALT COMM BUILD PERMT Applied: 04/07/2008 Applicant: HIGHLAND BUILDERS CORPORATION Issued: 05/20/2008 (719)499-9248 To Expire: 11/16/2008 Job Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Parcel No: 210108244003 Description: CORE AND SHELL FOR NEW SECOND FLOOR RESIDENTIAL CONDO AND GROUND FLOOR RETAIL SPACES IN THE BRIDGE STREET BUILDING (FORMER RUCKSACK) *****,r,r***********�*****,r,r,r*rr*********,e*,r,t,r,r,r***r******:***,r,r:*�Cond itions****************************,..****************************.**.**,�*.�*** Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0009897 The Developer shall submit executed agreements for encroachment, shoring and/or temporary access on, over, under or across adjacent properties. Such agreements shall be executed by and between the developer and the adjacent property owners, inclusive of the Town of Vail, prior to issuance of a building permit, for any and all improvements, temporary access or disturbance proposed off of Parcels 1, 2, 3, and 4; parts of Lots C and D, Vail Village First Filing. Cond: CON0009957 SEPERATE PERMITS WILL BE REQURED FOR FUTURE RETAIL SPACES 204-207 AND FINISH OF FUTURE SECOND FLOOR RESIDENTIAL UNIT. THIS BUILDING PERMIT IS FOR CORE AND SHELL ONLY. Cond: CON0009958 SPECIAL INSPECTION REPORTS REQUIRED PER STATEMENT OF SPECIAL INSPECTION. SEE PLANS Cond: CON0009972 Fire alarm permit required Entry: 05/09/2008 By: mcgee Action: AP Entry: 05/09/2008 By: mcgee Action: AP Cond: CON0009973 Fire sprinkler permit required. *****r******************************************s***��**************�*********************** TOWN OF VAIL, COLORADO Statement ************�***********��*******************�*��«*********r***************»***�+*******�*** Statement Number: R080000758 Amount: $7,854.27 05/20/200803:56 PM Payment Method: Check Init: DDG Notation: Highland Builders Corp 1311 ----------------------------------------------------------------------------- Permit No: B08-0072 Type: ADD/ALT COMM BUILD PERMT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $11,354.27 This Payment: $7,854.27 Total ALL Pmts: $11,354.27 Balance: $0.00 ***********�******�***+*+******************++*********************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 6, 878.95 PF 00100003112300 PLAN CHECK FEES 971.32 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- ***r*****************�*********t*****+**********�************************�****************** TOWN OF VAIL, COLORADO Statement *******�***********************«***+**********�****�*�*************�**********�**�*******�** Statement Number: R080000399 Amount: $3, 500. 00 04/07/200810:58 AM Payment Method: Check Init: CD Notation: Ck # 1226 (Highland Builders) ----------------------------------------------------------------------------- Permit No: B08-0072 Type: ADD/ALT COMM BUILD PERMT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $11,354 .27 This Payment: $3, 500.00 Total ALL Pmts: $3, 500 .00 Balance: $7, 854 .27 *****�*******************�**************�*******************r***�******�***�*****�+*****�*s* ACCOUNT ITEM L[ST: Account Code Description Current Pmts ' -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 3, 500.00 ----------------------------------------------------------------------------- , � u APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGN�j.�. � Project#: �"+��" ��� �d�3 . Building Permit#: -00 t 970-479-2149;(inspections} ������, � 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! CONTRACTOR INFORMATION General Contractor: Town of V�il Reg. � Contact Person and Phone#'s: 1.. ' c-tfk:� v � {, - � h `FL(�.� `" `� �- �1-�' Email address: � Fax#: �� __ S Contractor Signature: � � � .,>;-��7�/ _..i� COMPLETE VALUATIONS FOR BUILDING PERMIT Labor 8� Materials BUILDING: $ ' "L:� ��':{=�; ELECTRICAL: $ 5'�;,� �; �L �L; OTHER: $ +'�L} `rLy.� , �?� PLUMBING: $ -v ���_� , • MECHANICAL: $ �j-�� p.� TOTAL: $ �L ��;` �-,` For Parcel# Confact Ea /e Coun Assessors Office at 970-328-8640 or visit www.ea le-count .com Parcel# � �%i C:U D ��C%�=% � Job Name: Job Address: - �'-..;��C, 5 t,�k L�.� (.��v, `l C�� `, `,, X'..� - Legal Description Lot: Block: Filing: Subdivision: Owners Name: - Address: l�C�-j y'=�%��ti���u #:�• ;��, Phone: � �,� _:,�5-_= -- ,�.-„ � {' f'>/�(.V':'�. >'� 7' ., J Architect/Designer: Address: � Phone: 3��� � r r ,a ...� ; �1��� �. ��; L(7c�� � Engineer. �,���^ �,r�� Address: ���• ��, Phone: � ,_ �� Detailed description of work: A .. ����w�c '��"-�.. �i' �`�v���t� Work Class: New( ) Addition ( ) Remodel (►�f Repair( ) Demo ( ) Other ( ) Work Type: Interior( ) Exterior( ) Both (j�'� Does an EHU exist at this location: Yes ( ) No ( a�- Type of Bldg.: Single-family( ) Two-family( ) Multi-family( �'Commercial(��''Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: � No. of Accommodation Units in this building: NolT e of Fire laces Existin : Gas A liances "Gas Lo s �Wood/Pellet Wood Burnin � 'f No/T e of Fire laces Pro osed: GasA liances � Gas Lo s �, �Wood/Pellet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( � No ( ) Does a Fire Sprinkler System Exist: Yes (�' No ( ) �lS��,���� I�, " , I = � � � ���- � Date Received: �" D ���' :� ' ! � .�r� �. � Received'By: C -' � , , ,�� r k= 3 � � TOWN OF VAIL F:\cdev\FORMS\Permits\Building\building�ermit_ - - . "`-�°� Page 1 of 7 04/17/2007 May 01 08 10:55a Linda Malaby 970-984-0700 p.1 Mark Fi�tllenbeck ' FroM: Lirtds Malaby[mafaby�lwaii.nQtJ T� M�arK Hail�nbe�ck I 23,2�0810:46 AM Cc: D'iak Brown;Jetf Selby , Suhjsct: Stagin�Ag�eement�etl er RED LYON CQ rTDOMIN�UM A,SSOCXAT�ON 610 W.L�ON;��EAD C�tCLE,SZTITE 7,00 VAIL,COLORADp 81657 � 970-4'f6-3S35 Agri123,2008 Mx.Mark Hallenbxk . , ' and Buildcrs � 2598 Palmer Park Blvd. . ; , Colocado Sprit�,gs,CO 80909 � . � • Dear Ntack: . . . It is the Red Lion Caadamiaium Associatiou's w ulerstaading thet yon wi��Q�a y�g���Zocated iw the � poc�cet park beiw�een the itucksack Huild'ung aud�he Rad�,iat Building . The Association e�ptavcs tbc staging as you hsve outlirtod with certsi����n�: 1) There will be accesa tc our commercial ta�ar�t,The Ski$ar,ead thcir business sigtamge sod awning will not be obstructed from the p�b)x�yle�,v� th ir 2) There w,iIt be ea4y acce.as for the c+esidentiu d unit above The Ski Bar, 3) If any damagc occucs to onr pm,p�rty or ta�aata'bnsiness during the wnsttvctiionlstaging Pxocess, Hig,�tiand Btulders will be hetd liabk.and 4) A,1I conditions o£staging bev�b��t�by�Ta�of.Vaii. ._ � • , :a. If the�bove are acceptable terms,p[es�se sign belo�v and sc�ud a fa�similt copy to 970-476-6366. Red Lxon Condo,p�oc. �d$��� ��'�'-- /C• Linda R.Maleby, Manag�r � Mack H�iler�beck,Cp�. t a ,:.'. j ��va�u�, } BUILDING PERMIT APPLICATION CHECKLIST SINGLE FAMILY/DUPLEX CHECKLIST This checklist is to be used with any single family/duplex permit (new construction , addition, or remodel application.) C�Town of Vail Design Review Board approval must first be obtained (may not apply to interior remodels) C� Plan Check Fee must be paid at the time of application for projects over$100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: Arc itectural Plans __ Site Plans. Provide all site plan information as required for the Design Review Application for your project. Refer to the DRB application checklist for complete details. !� Construction staging plans. Provide construction staging and materials storage site plans. � Floor plans. Complete floor plans provided for each level. Complete dimensions, drawing scale noted, use of each room shown on the plans. Location of inechanical equipment clearly shown �' Building Elevations N,W,S,E elevations. Show all proposed exterior finish materials, guardrails, /windows, doors, and finish grades. C1 Window sizes and operation types. Specified on the floor plans or elevations. a' Reflected ceiling and finish plan. Required if fire alarm or fire sprinkler work is required. C9� Stairways, guards, and handrails Show all stairway details with rise/run, handrail and guard details C� Roof plan. Show all roof covering materials (Class A covering required) and underlayment, roof pitch C� Building cross sections. Show roof, wall, floor construction assemblies and insulation R values. Show roof and crawl space ventilation. Show ceiling heights in rooms and crawl spaces. C� Rescheck compliance certificate and inspection checklist(new construction and additions only). Provide a complete signed compliance certificate and inspection checklist. Verify all exterior building is detailed on the building plans as required on the Rescheck compliance report. � Fireplaces. All fireplace types shown on the floor plans. Specify gas log set, or gas appliance at each fireplace. Structural Plans 0� Soils Report. Include 2 copies of the soils report for your lot. � All sheets of the structural plans stamped and signed by a Colorado State Licensed Engineer. C� Design specifications sheet. Roof live load, Deck live load, Floor live load, Wind Speed/Exposure, Soils report number and soil bearing capacity referenced per the soils report. C�/Foundation plan. Provide a complete foundation plan with all footing/foundation section details C3' Framing plans. Provide complete framing plans for floors, decks, roofs. All beams, joists, rafters or trusses clearly shown. Include framing construction details and connection schedules. Ot r items Asbestos form completed. Asbestos test and report provided if any existing construction is �proposed to be disturbed. See Town of Vail asbestos testing requirement form. fY Plan check fees. Plan ch c ee e paid with your application. The building permit and recreation fees will be paid upon nce a building permit. 1 have read and understand the requiremen f thi hecklist. If any required information is missing from the application, I und nd pplicati ill not be ac epted. �� Ap cant's Signature Date F:lcdev\FORMS\Permits\Building\TOVSingleFamilyChecklist 4-16-2007.DOC u � : ����• ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICAT�ON • I have included the asbestos test a d port with my building permit application � c� c,�( �k�CV-�x GF--t" �-(.���TDV�� a � � applicant signature date � /� S a a��0 0 ZZ ���r OR • I certify my project will not disturb or remove more than 160 s.f. of building material. The construction plans submitted with my application clearly indicate this information. (This will be veri�ed during plan review, and will delay your project if found to be inaccurate) applicant signature date OR • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date F:\cdev�FORMS\Permits\Building\building�ermit 4-17-2007.DOC Page 5 of 7 04/17/2007 a u , . ������. WHEN A"PUBLIC WAY PERMIT" IS REQUIRED PLEASE READ AND CHECK OFF EACH OF THE FOLLOWING QUESTIONS REGARDING THE NEED FOR A "PUBLIC WAY PERMIT": o Is this a new residence? YES NO v o Does demolition work being performed requ' e the use of the Right-of-Way, easements or public property? YES��NO o Is any utility work needed? YES v NO o Are there any improvements being done to the driveway? YES �NO o Is a different access needed to the site other than the existing driveway?YES_NO ✓ o Is any drainage ork being done that affects the Right-of-Way, easements, or public property? YES � NO o Is a"Revocable Right-of-Way Permit" required? YES ✓ NO o Is the Rightt-of�- ay, easements or public property to be used for staging, parking or fencing? YES l/ NO If answer it N0, is a parking, staging or fencing plan required by Public Works? YES NO If you have answered YES to any of these questions, a"Public Way Permit° must be obtained. "Public Way Permit°applications may be obtained at the Public Works office or at Community Development. If you have any questions pleas r doval in Public Works at 970-479-2198. I HAV E J E ALL THE QUESTIONS. l �t S ontractor Signature Company Name Job or Project Name: � � �su Date Signed: -D � � 1� �� F:\cdev\FORMS\Permits\Building\building,�ermit_4-17-2007.DOC Page 6 of 7 04/17/2007 �i � TO WN OF VAIL 42 West Meadow Drive Yail Fire Department Vail, Colorado 81657 970-479-2250 December 30, 2008 Jeff Selby, Owner Bill Pierce, Architect Tyson Dearduff, Architect Mark Hallenbeck, Builder Re: 288 Bridge Street (Rucksack Building) TCO Issues (B08-0072) Dear Sirs: Based on a copy of a resolution furnished to the Town of Vail dated September 29, 2007, from the Rucksack Condominium Association in support of a permit application for the redevelopment of the Rucksack Building at 288 Bridge St., and given the plans were reviewed and approved based in part on the submittal of the resolution, addressing a commitment and agreement to install the required fire and life safety systems, and upon inquiries made by and statements from William Gardiner, and as a result of an on-site meeting with Mr. Gardiner, wherein he expressly indicated a willingness to allow the subcontractors installing the fire sprinkler system and fire alarm system within the building to access his unit , and Mr. Gardiner stating he had permission from the owner of the condominium above to allow us to view the interior of her condominium with the fire sprinkler contractor in attendance for the purpose of assessing any extenuating circumstances that would prevent the installation of fire and life safety systems, and wherein no such extenuating circumstances were found, it is the opinion of Vail Fire & Emergency Services that the fire sprinkler and fire alarm systems should be installed and the entire building brought into compliance with the applicable codes and the plans and details as submitted for the permit. The presence of commercial real estate below occupied sleeping quarters, the limited access and egress, the extent of combustible construction and number of habitable floors presents a distinct hazard to the life safety of the occupants. Furthermore, it is the opinion of Vail Fire & Emergency Services that no additional commercial spaces should receive a Certificate of Occupancy or Temporary Certificate of Occupancy until such time as the fire sprinkler and fire alarm systems have been installed and tested. Some consideration may be given to allow occupancy of the commercial space only if there is plan submittal, evidence of permission to proceed with the installations, a clear and concrete schedule to complete the installation, and some reasonable assurance the work will proceed without delay. No permission to delay the installation until spring, summer or next year will be considered. Rucksack Page 2 Please contact us if you wish to discuss this or other issues. Sincerely, Michael McGee Deputy Chief Vail Fire & Emergency Services 970 479-2135 � DH ENGINEERING JUDGMENT FIRESTOP DETAIL PROJECT: BRIDGE ST VAIL /�'���/ CONTRACTOR: HIGHLAND BUILDERS ���/`" F-RATING = 1-HR. � BOTTOM VIEW SECTION A-A A �j � � 2 3 � - - ----- -� I I I I I I I I I I I I I I L--- - - - -J 4 A 1.WOOD FLOORICEILING ASSEMBLY(ULIcUL CLASSIFIED L500 SERIES)(1-HR. FIRE-RATING). 2.OPENING FRAMED OUT AND LINED WITH FIRE-RATED GYPSIlM WALL BOARD. 3. PENETRATING ITEMS TO BE ANY OF THE FOLLOWING : A. MAXIMUM 4" NOMINAL DIAMETER STEEL PIPE. B. MAXIMUM 2"NOMINAL DIAMETER COPPER PIPE. C. MAXIMUM 3" DIAMETER CABLE BUNDLE TO CONSIST OF ANY COMBINATION OF THE FOLLOWING : A. MAXIMUM 71C N0. 12 AWG POWER CABLE WITH PVC JACKET. B. MAXIMUM 25 PAIR N0.24 AWG TELEPHONE CABLE WITH PVC JACKET. C. RGIU COAXIAL CABLE WITH PVC JACKET. D. MAXIMUM 31C N0. 8 AWG METAL-CLAD CABLE. E. MAXIMUM 31C(+GROUND) N0. 8 AWG COPPER CONDUCTOR CABLE (ROMEX). F. MAXIMUM 518 DIAMETER FIBER-OPTIC CABLE WITH PVC JACKET. G. MAXIMUM 3/4" DIAMETER COPPER GROUND CABLE WITH OR WITHOUT PVC JACKET. H. MAXIMUM 1-114"DIAMETER SINGLE OR MULTIPLE CONDUCTOR TYPE MI CABLE(SEE NOTE N0.4 BELOVIn. I.ANY CABLES, METAL-CLAD CABLES, OR ARMORED CABLES CURRENTLY LISTED UNDER THE THROUGH PENETRATING PRODUCTS CATEGORY. 4. HILTI FS 657 FIRE BLOCK(2"THICK, 8"WIDE, 5" DEEP, REF. FRONT VIEW) FLUSH WITH BOTTOM. NOTES : 1. MAXIMUM SIZE OF OPENING= 12"x 12". 2.ANNULAR SPACE= MINIMUM 114", MAXIMUM 1". 3.APPLY HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT IN ANY VOID THAT MAY EXIST AROUND PENETRANTS OR FIRE BLOCKS. THIS EN6INEERING JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXPECTED TO PASS THE STATED RATINGS IF TESTED. (REFERENCE : UL SYSTEM N0.W-L-8013, C-AJ-8056 8�F-C-1059) HILTI,Inc. Sheet �of 1 Drawing No. Tulsa,Oklahoma USA(800)879-8000 Scale 3132"=1" Designed by 102991 a Hilti Firestop Systems Date pec.��,2ooe Saving Lives thro Education DH ENGIN� � � '-JUDGMENT FIRESTOP DETAIL : PROJECT: BRIDGE ST VAIL � CONTRACTOR: HIGHLAND BUILDERS FRONT VIEW SEGTION A-A . . . A G� � U .` � NO ACCESS 2 � �. THIS SIDE � 3 A G� � . � � � _ . 1. CONCRETE BLOCK WALL ASSEMBLY(ULIcUL CLASSIFIED)(MINIMUM 8"THICK)(2-HR. FIRE-RATING). `�. PENETRATING ITEM TO BE ONE OR MORE OF THE FOLLOWING : � A. MAXIMUM 3" NOMINAL DIAMETER PVC PLASTIC PIPE. - B. MAXIMUM�" NOMINAL DIAMETER STEEL PIPE. 3. MINIMUM 8" DEPTH HILTI CP 620 FIRE FOAM. � NOTES : 1. MAXIMUM SIZE OF OPENING=48"x 20". 2.ANNULAR SPACE=MINIMUM 0", MAXIMUM 4112". ' 3.THIS SYSTEM IS DESIGNED AS A COLD SMOKE SEAL ONLY. . � THIS ENGINEERING JUDGMENT REPRESENTS A FIRESTOP SYSTEM THAT WOULD BE EXP�CTED TO PASS THE STATED RATINGS IF�ESTED. . (REFfRENCE : UL SYSTEM N0. C-AJ-8096� " HILTI,Inc. Sheet �of 1 D'rawing No. Tulsa,Oklahoma USA(800)879-8000 Scale ��.a�., Designed by _ �OA��Aa Hilti Firestop Systems oare �c.��,2008 � � Saving Lives thro Education � Mark Hallenbeck From: Fischer, Marco[Marco.Fischer@hilti.com] Sent: Wednesday, December 17, 2008 9:33 PM To: mark@highlandbuilders.com Cc: Coleman, Mark Subject: 288 Bridge St. project Attachments: 102991a Layout1 (1).pdf; 102992a Layout1 (1).pdf Mark, unfortunately the Engineering Judgments took longer than anticipated, the workload just before the holidays is huge. Attached you will find the two Engineering Judgments for the discussed situations. Please note that EJ 102992a for the large wall penetration is designed as a 'cold smoke seal only', I need to discuss some details with the engineer tomorrow morning. I will be in touch woith you afterwards to discuss the next steps. Thanks a lot for you�patience, hope everythings works out as planned. Best regards, Marco Marco Fischer Fire Protection Specialist Colorado/Utah Hilti North America 5400 S.122nd E.Ave I Tulsa,OK 74146 P 800-879-8000 I F 918-459-1815 I M 303-229-4778 E marco.fischerCcDhilti.com www.us.hilti.com From: Hensley,Clay Sent: Wednesday,December 17,2008 1:53 PM To: Fischer,Marco Subject: bridge «102991 a Layout1 (1).pdf» «102992a Layout1 (1).pdf» Because of the numerous field conditions encountered, it is not always possible to identify a firestop system that has been tested /classified by a nationally recognized independent testing laboratory (such as Underwriters Laboratories, Factory Mutual, Omega Point, etc.). In such a case, an Engineering Judgment ("EJ") may be appropriate. An EJ represents a firestop system that would be expected to pass the stated ratings and requirements if tested. All Hilti EJ's are designed in accordance with the International Firestop Counsel ("IFC") guidelines. These EJ's are designed by our experienced degreed fire protection engineers using, as the basis for our opinion: relevant 3`�-party classified systems tested in accordance with ASTM E-84, ASTM E-119, ASTM E-136, ASTM E-814, ASTM E-1966, ULC-S115-M95, UL 263, UL 723, UL 1479, or UL 2079, wide-ranging related internal testing of our firestop products, and extensive knowledge and experience of the perFormance characteristics of Hilti firestop products, and firestopping technology generally. Pursuant to IFC guidelines, each EJ is intended for one specific jobsite, since even slight variances from one application to the next can affect system perFormance. Best regards, Clay A. Hensley Fire Protection Department Hilti, Inc. � � BRIDGE STREET BUILDING 288 Bridge Street, Vail, CO, 81657 H I � TOP ASSEMBLIES ������ ?�NOF YAIL'j �jd 8'—Q� �Z �nbematlonN su codellnMn+.aomt tidity oi permit The�N�e or grsrMing ot a perrrdt ��ot be aomtrued b be a�t(a�Or�n�pprowl of my Mola�on at �r otth�pav�bm d tFii�cod�aoI �y otMr ad�no�oi th� Junedicdon.Pamil�Pnwmfrp otai���lhorih b viol�be ct�noetth� prov�ion.a a�ood.«ott�r a�.iuritak�ain.h�N noc ar ve�l.The�a a p�n�b�d on�n�on do�+�w+/ otlHr dMa:heA noip�th�bu�dinp ofi�i from tiqWrkq tt� oonedion of N�on in qie�rnducdon docttmlMt�nd a1fNt deh.TM buildin�oi�l k�o aWhoriud b prwaM oowp�noy orttw d• �la rMMtion ot I��or d�q►o11�to�diu�oKd �t�ws� OB� HIGH�. �T �UILDERS CORPORATION � 120 Willow Bridge Rd., suite 7 Vail, CO 81657 Phone: 970-476-4458 Fax: 970-476-4951 Town of Vail OF'FI�� COPY � -��1t�i� UUcUL SYSTEM N0.F-C-1009 �` METAL PIPE THROUGH 1-HR. OR 2-HR. WOOD FLOOR/CEILING ASSEMBLY F AND T-RATING=1-HR.OR 2-NR. � 0 L-RATING AT AMBIENT=LESS THAN 1 CFM/SQ.FT. N L-RATING AT 400°F=4 CFNUSQ.fT. � 0 TOP VIEW SECTiON A-A � —�— 3 � 1 2 4 f 1 I I 1 I I I I ! I I A � I I # A � I I i i � I I I I � I i I �I 1 I I I I I I I 1 I I I 1 I i i � � i I I I I I i I I I I I I I 2 5 1.WOOD FLOORICEILING ASSEMBLY(UUcUL CLASSIFIED L500 SERIES)(1-HR.OR 2-HR,fIRE-RATING) (2-HR.SHOWN). 2.GYPSUM WALL ASSEMBLY(UUcU1 CLASSIFIED U300 SERIES)(1-HR.OR 2-HR.FIRE-RATING)(2-HR. SHOWN). 3.PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A.MAXIMUM 4"NOMiNAL DIAMETER STEEL PiPE(SCHEDULE 10 OR HEAVIER). B.MAXIMUM 4"NOMlNAL DIAMETER CAST OR DUCTILE IRON PIPE. C.MAXIMUM 4"NOMINAL DtAMETER COPPER PIPE OR TUBING. D.MAXIMUM 4"NOMINAL DIAMETER STEEL CONDUIT OR EMT. 4.MINIMUM 3/4"DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT,CP 601S ELASTOMERIC � FIRESTOP SEALANT,OR CP 606 FLEXIBLE FIRESTOP SEALANT,FLUSH WITH TOP SURFACE OF FLOOR OR SOLE PLATE. 5.GENEROUS BEAD OF HILTI FS-ONE lNTUMESCENT FIRESTOP SEALANT,CP 6015 fLASTOMERIC FIRESTOP SEALANT,OR CP 606 FLEXIBLE FIRESTOP SEALANT,FLUSH IMTH BOTTOM SURFACE OF LOWER TOP PLATE. MOTES: 1.DIAMETER OF OPENING TO BE MAXIMUM 1"LARGER THAN DIAMETER OF P1Pf OR SQUARE-CUT WITH A MAXIMUM DIMENSION 1"GREAI'ER THAN THE DIAMETfR OF PIPE. 2.WHEN LUMBER PLATES ARE DISCONTINUOUS,ATTACH A NOMINAL 1-1/2"WIDE 20 GA.(OR HEAVIER)GALVANIZED STEEL PLATE TO EACH END OF LUMBER PLATE.STEEL PLATES -SHOULO OVERLAP 1/2"ONTO LUMBER,AND SECURED VYITH STEEL SCREWS OR NAILS. 3.ANNULAR SPACE=MINIMUM 0",MAXIMUM 1". 4.L-RATINGS APPLY ONLY WHEN HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT IS USED. 'Hilti. 0utperform. Outl st. f�ti,Inc.(U.S.)1-800-879-8000•www.us.hliti.co espar'�ol 1-800-879-5000•Hilti Firestop Systems�e 2007 205 � ULicUL SYStEM N0.F-C-1059 METAL PIPE THROUGH 1-HR. OR 2-HR. WOOD FLOOR ASSEMBLY F-RATING=1-HR.OR 2-HR. N � T-RATING=0-HR.OR 112-HR. o : � : 0 � � 0 TOR YIEW SECTION A-A LL ° T - 1 2 3 4 � � � ► � � � � � � � � A � � � � q � i � � � � � I I I 1 1 1 � f f I I I I I I i � 1 I I I 1 I I I I ! I I I t I I I 1 � � I I 4 1.WOOD FLOOR/CEILING ASSEMBLY(UWLC CLASSIFIED L500 SERIES)(1-HR.OR 2-HR.FIRE-RATING) (2-HR.SHOWN). Z.LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER,PLYWOOD,OR FLOOR TOPPING MU(TURE. 3.PENETRATING ITEM TO BE ONE OF THE FOLLOWING: A.MAXIMUM 6"NOMINAL DIAMETER STEEL PIPE(SCHEDULE 40 OR HEAVfER). B.AI�AXIMUM 6"NOMINA!DIAMETER CAST IRON PiPE. C.MAXIMUM 6"NOMINAL DIAMETER STEEL CONDUR. D.MAXIMUM 4"NOMINAL DIAMETER EMT. E.MAXIMUM 2"NOMINAL DIAMETER FLEXIBLE STEEL CONDUIT. 4.MINIMUM 314"DEPTH HtLTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 5.HiLTI FS-ONE INTUMESCENT FtRE3TOP SEALANT: A.MiNIMUM 518"DEPTN OF SEAl.ANT FOR A 1-HR.FIRE-ltATiNG. B.MlNIMUM 1-114"DEPTH OF SEALANT FOR A 2-HR.FIRE-RATING. NOTES:1.M/UqMUM DtAMETER OF OPENING=7-518". 2.ANNULAR SPACE=MINIMUM 114",MAXIMUM 3/4". 3.CHASE WALL(NOT SHOVItN,OPTIONAL)-THE 1'HROFJGH PENETRANT MAY BE ROUTED THROUGH A 1-HR.OR 2-HR.FIRE-ltATED GYPSUM CHASE WALL ASSEMBLY. � '� 1'�11ti- ��p@l'�O!^la'!� OJ.1t�a.St� �os _ _._ - Hifti,tnc.(U.S.) 79-8000•www.us.hifti.com•en espanol 1-800-879-5000•Hitti Firestop Systems Guide 2007 . UUCUL SYSTEM N0.F-C-1106 METAL PIPE THROUGH WOOD FLOOR ASSEMBLY F-RA71NG=1-HR. �, T-RATING=1/4HR. ° � TOP VIEW � —�--- SECTiON A-A � U LL 1 2 3 6 4 I I I I I I � � .A I I I I j j A I I I I I I I I � � I I I I � I I I I i i I I I � � I I i I � � I I I I � 6 3 4� 1.WOOD FLOORICEILING ASSEMBLY(UUcUL CLASSlFIED L500 SERIES)(1-HR.FIRE-RATING). 2.LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR Of LUMBER,PLYYVOOD,OR FLOOR TOPPING MIXTURE. 3.PENETRATING ITEM TO BE ONE Of THE FOLLOWING; A.MAXIMUM 4"NOMINAL DlAMETER STEEL PIPE(SCHEDUL�10 OR HEAVIER). B.MAXIMUM 4"NOMINAL DIAMETER CAST IRON OR DUCTILE IRON PIPE. C. MAXIMUM 4"NOMINAL DiAMETER COPPER PtPE OR COPPER TUBING. � D.MAXIMUM 4"NOMINAL DIAMETER STEEL CONDUIT. E.MAXIMUM 4"NOMINAL DIAMETER EMT. 4.MINIMUM 314"DEPTH HILTI CP 606 FLEXIBIE FIRESTOP SEALANT OR HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 5.MINIMUM 5/8"DEPTH HILTI CP 60S FLEXIBLE FIRESTOP SEALANT OR HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 6.MINIMUM 1/2"BEAD HILTI CP 606 FLEXIBLE FIRESTOP SEAi.ANT OR HILTI FS-ONE 1NTUMESCENT FIRESTOP SEALANT AT POINT OF CONTAC7. NOTES: 1.MAXIMUM DIAMETER OF OPENING=5". 2.ANNULAR SPACE=MINIMUM 0",MAXIMUM 7/8". 3.CHASE WALL(NOT SHOWN,OPTIONAL)-7HE THROUGH PENETRANT MAY ROUTED 1'HROUGH A 1-HR.FIRE-RATfD GYPSUM CHASE WALI.. Hilti. Outperform. Outl st. Htlti,Inc.(U.S.)1-800-879-8000•www.us.hiltl.co espanol 1-800-879-5000•Hilti Firestop Systems�,Ti'ide 2007 207 - � .- . UL SYSTEM N0.F-C-2030 PLASTIC PIPE THROUGH WOOD FLOOR/CEILING ASSEMBLY F-RATING=1-HR.OR 2-HR. $ ; T-RATING=0-HR.,3/4HR., 1-HR., 1-1/2-HR.OR 2-HR. N ;: Q . BOTTOM V(EW SECTlON A-A Q ; N ' 5 " � -- -- 1 2 6 � � A __ __ p -- -- 8 3 4 5 1.WOOD FLOORICEIUNG ASSEMBLY(UL CLASSIFIED L500 SERIESj(1-HR.OR 2-HR.F{RE-RATING) (2-HR.SHOWN). 2.LUMBER OR PLYWOOD SUBFLOOR WITH FINISH FLOOR OF LUMBER,PLYWOOD,OR FLOOR TOPPING MtXTURE. 3.WOOD TOP PLATE. 4.GYPSUM WALL ASSEMBLY(1-HR.OR 2-HR.FIRE-RATING)(2-HR.SHOWN). 5.PEMETRATING ITEM TO BE ONE OF THE FOLLOWING(ALSO SEE NOTE N0.2 BELOVI�: A.MAXIMUM 4"NOMINAL DIAMETER PVC PLASTIC PtPE(CELLULAR AND SOLID CORE). B.MAXIMUM 4"NOMINAL DIAMETER ABS PLASTIC PIPE(CELLULAR AND SOLID CORE). C.MAXIMUM 4"NOMINAL DIAMETER FRPP PLASTIC PIPE. D.MAXIMUM 4°NOMINAL DIAAAETER CPVC PLASTIC PIPE. 6.HlLTI FS-0NE INTUMESCENT FIRESTOP SEALANT INSTALLED TO THE MAXIMUM EXTENT POSSIBLE. 7.HILTI CP 643N FIRESTOP COLLAR WITH FASTENING HOOKS(SEE TABLE BELOVI�. 8.3/4"WOOD SCREWS AND WASHERS TO ATTACH EACH FASTENING HOOK. - NOMINAL PIPE DIAMETER PRODUCT DESCRIPTION NO.OF FASTENING HOOKS MAXlMUM HOLE SIZE � 1-1/2" CP 643 50/1.5"N � 2 2.112^ 2" CP 643 6312"N 2 2-518" 3" CP 643 9013"N 3 4" 4" CP 643110/4"N 3 5" NOTES : 1.ANNULAR SPACE=MINtMUM 0",MAXIMUM 1i2". � i� 2.CLOSED OR VENTED PIPING SYSTEM.(PVC,ABS,FRPP=SCHEDULE 40,CPVC=SDR 17). " � Hi1ti.�utperForm. Outlast. 208 Hilti,Inc.(U.S�800-879-8000•www.us.hilti.com•en espanol 1-800-879-5000•Hifti Frestop Systems Guide 2007 . l� SYSTEt�I t� F-C-2128 . �� �� PLASTIC PIPE THR�UGH 1-HR, �R 2-HR,..W�OD FL�OR/CEP F-RATD� = 1-F�t. � 2-FAt. � T-RATD�G = 1-I�t. OR P-Flt, � > �� � SECTI�I A-A 1 2 3 i i i i �� i i � i i � i i i i i i i i � i � � i i i i i i � ► � i ► � o o � � � � � � � i i i i i A � � � i q ii i i ii ii 5 i i i 6 7 4 L V�D FL�t/� ASSEMIBLY (l�. CLASSIfIED L500 SERIES) ti-F#2, �t 2-i�Nt. �-RATD�Q (�-t� Sl�M(�U. Z PENETRATArG TTEM TO � � ff TF� F�l�MIII� tSEE I�UTE NQ 3 � � . A. MAXIMIJM Z' I�INAL DIAMETER PVC PLASTIC PIPE t�EU.U.AR �ID SQ.ID C�. B. MAXIMIUM 2' I�D�AI. DIAlIETER ABS PLASTIC PI� tCEU.ULAR P�iIl Sn.ID C�RD, C� MAXD�M Z` I�hQNAL DIAl�TER CPVC PLASTIC PIPE. � 3. lI�1M 3/4' DEPTH � HILTI FS-�lE INTUMESCENT fIREST� SEALA�IT. 4, MIMNUM 5/8' DEPTH FQLTI FS-�E INTUI�SCENI' �IREST�' SEALANT. � � �� 5. MDVIl�I 1/2' BEAD � HII.TI FS-� INTl1MESt�NT �IRESTO' SiEAL�IT AT POINT �' CONTACT. :-�� �° ��� � HIL.TI CP 643N fIREST� C�L.L.AR VITH FASTENING l�CS. 7, HILTI 3Ji6' TOGCLER B[LTS TD ATTACH EACH FASTE�QI� F�C TQ FLmt/CEILING ASSEM�.Y, N�TES � 1. MAXIMI�! DIAMIETER � �EI�QNG = 3'. � 2 A�N�IlLAR SPACE = MIMMIl1Mi 0', MAXD�M 5/8'. ' �- 3� CL�ED Ot VENTED PIPDVG SYSTEM. tPVC � ABS = �DIx.E 40, CPVC = SDR ln. � �� 4. CFIASE VALt Q�T SI�IN, �'TI�IAU - TFE T1�Ra1GFl PENETRANT MAY � R�UTED I � TFIR�IGH A 1-HR� � 2-F�t. FIRE-RATED Gl(PSUM CHASE VI�.L. � � .F P ' ��� �;Hilti. 0utperform. 0utlast. ,: F�fi,inc.(U.S.)1-800-879-8000•wwwus.t�tl.c�en espanoi 1-800-879-5000•HiFti Frestop Syst�ide 2007 2� �� � . � -- - - I UL SYSTEM N0. F-C-2160 ; PLASTIC PIPE THROUGH 1-HR. OR 2-HR. WOOD FLOOR ASSEMBLY ' F-RATING= 1-HR.OR 2-HR. � f� ` I C ��i I T-RATING=1-HR.OR 2-HR. � . ; a I a � TOP VIEW LL � T SECTION A-A 1 2 3 4 r-i---------- � � : `f A � � q � � - � i i � � � � � � � � � � � 5 . � :�, = � � �. � 1.WOOD FLOORICEILiNG ASSEMBLY(UL CLASSIFIED L500 SERIES)(1-HR.OR 2-HR.FIRE-RATING)(2-HR. , . SHOWN). ' 2. LUMBER OR PLYWOOD SUB FLOOR WITH FINISH FLOOR OF LUMBER, PLYWOOD,OR FLOOR TOPPING MIXTURE. - 3.PENETRATfNG ITEM TO BE ONE OF THE FOL�OWING(ALSO SEE NOTE N0.3 BELOW): 3 A.MAXfMUM 2"NOMINAL DIAMETER PVC PLASTIC PIPE(SCHEDULE 40)(CELLULAR OR SOLID , CORE)(CLOSED OR VENTED PIPING SYSTEM). B. MAXiMUM 2"NOMINAL DIAMETER CPVC PLASTIC PIPE(SDR 13.5)(CLOSED PIPING SYST� � (�)��j `. F : V�\V� 4. MINtMtlM 3/4"DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. 5. H{LTI FS-ONE INTUMESCENT FIRESTOP SEALANT INSTALLED INTO ANNULAR SPACE TO FILL VOID TO MAXIMUM EXTENT PDSS►BLE. - NOTES.- >. .ssAX�,t�U.tfO/.4.ffETEROFOPEN/N�'i=4° 2.ANNULAR SPACE=MINIMUM 1/2", MAXIMUM 1-1/8". � ` 3.CHASE WALL(NOT SHOWN,OPTIONAL)-THE THROUGH PENETRANT MAY BE ROUTED THROUGH A 1-HR.OR 2-HR,FIRE-RATED GYPSUM CHASF WAILASSF�j�.y �� . � � Hilti. Outperform. Ou 210 �ilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com�Ven espanol 1-800-879-5000•Hilti Firestop Systems � � �� �� UL SYSTEM N0.F-C-2232 � PLASTIC PIPE THROUGH WOOD FLOORlCEILING ASSEM - �� � t� F-RATING=1-HR. - � ` �� T-RATING=3l4 AND 1-HR. � BOTTOM VIEW SECTION� N 2 LL 3 1 O o .. � � o -0 _ :�. � O ��� � O � 3 ��; o A ° � A � , :� 7 6 5 4 1.WOOD FLOORICEILING ASSEMBLY(tfL CLASSlFIED L�0 SERIES)(1-HR.fIRE-RATING). 2.PENETRATING ITEM TO BE ONE OF THE FOLLOWiNG(ALSO SEE NOTE N0.3 BELOVI�: A.MAXiMUM 4"NOMINAL DIAMETER PVC PLASTIC PIPE(CELLULAR OR SOUD CORE). B.MAXIMUM 4"NOMINaI.DIAMETER CPVC PLASTiC PIPf(CLOSED PIPING SYSTEM ONLI�. ; 3.MiNIMUM 518"DEPTH HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT. ' � 4.HtLTI CP 648E FIRESTOP WRAP STRiP(NOMINAL 3/16"TH1CK,x 1-3/4"WIDE)CONTINUOUSLY WRAPPED ' AROUND THE OUTER ClRCUMFERENCE OF THE PIPE,COVERING TWO TIMES,Wl7H ENDS BUTTED AND � � � ��� HELD iN PLACE WITH TAPE. �� - 3.HILTI RETAINING COLLAR WRAPPED OVER WRAP STRIPS,OYERLAPPING MINtMUM 1". ' � 1 6.HILTI RETA1NiNG COLLAR CLAMP FASTENED AT MID-HEIGHT OF HILTI RETAINING COLLAR. � ' � . 7.EVERY OTHER TAB OF RETAINING COLLAR SECURED TO GYPSUM CEILING WITH 114"DIANIETER x 1-1/Z" � y LONG STEEL TOGGLE BOLTS WITH 3/4"DIAMETER WASHERS(EX.HILTI TOGGLER BOLTS), �, s:� � � NOTES: 1.MAXIMUM DIANIETER OF OPENING=5". � � 2.ANNULAR SPACE=MINIMUM 0",MAXIMUM 1/2". ; 3.CLOSEO OR VENTED PIPiNG SYSTEMS(PVC=SCHfDULE 40;CPVC=SDR 13.5). � = 4.AS AN ALTERNATE TO UTILIZING CP 648E WRAP STRiPS WITH RETAINING COLLAR, � HILTI CP 643N FIRESTOP COLLAR N1AY BE USED.EVERY FASTENING HOOK OF FIRESTOP � COLLAR TO BE ATTACHED TO GYPSUM CEIUNG WITH 114"DIAMETER x 1-1/2"LONG � ` � STEEL TOGGLE BOLTS WITH 3!4"DIAMETER WASHERS(EX.HILTI TOGGLER BOLTS). : �'�. �� � ,.� � � � ft k 3t. * � ,Hilti. Outperform. Out�ast. I 2t?Q?.;,%° N�li,kic.(U.S.)1-800-879-8000•www.u�.com•en espar�ol 1-800-879-5000•Hilti Firestop�ems Guide 2007 213 I . UL SYSTEM N0.F-C-2270 ���� rLOWGUARD GOLD�OR BLASEMASTER� PIPE THROUGH WOOD FLOOR ASSEMBLY F-RATING=1-HR. � T-RATING=1-HR. � 0 BOTTOM VIEW SECTlON A A � N N ll.. 5 1 2 4 6 � A A 4 3 ,� � 7 6 �. 1.WOOD FLOOR/CEfLING ASSENIBLY(UL CLASSIFfED L500 SERIES)(1-HR.FIRE-RATING). 2.LEIMBER OR PLYW�D SUBFLOOR WITH FINISH FLOOR OF LUMBER,PLYWOOD,OR FLOOR TOPPING MtXTURE. 3.WOOD TOP PLATE. 4.GYPSUM WAlL ASSEMBLY(UWLC CLASS{FfED U3�OR 11400 SERIES)(1-HR.FIRE-RAT[NG). 5.PENETRATING 1'f'EM TO BE ONE OF THE FOLLOWING(CLOSED OR VENTED SYSTEM): A.MAXiMUM 2"NOMINAL DtAMETER FLOWGUARD GOLD�CPVC PIRE(SDR 11). B.MAXtMUM 2"NOMINAL DIAAIIETER BLAZEMASTER�CPVC PIPE(SDR 13.5). 6.MINIMUM 3I4"DEPTH HILTI FS-ONE INTUMESCENT FfRESTOP SEALANT. 7.MINIMUM 112"BEAD HILTI FS-ONE INTUNfESCENT FIRESTOP SEALANT AT POINT OF CONTACT. NOTES: 1.MAXIMUM DIAMETER OF OPENING=3". 2.ANNULAR SPACE=MININIUM 0",MAXIMUM 5f8". 3.CPVC PIPE MAY BE INSTALLED WITN CONTINUOUS POINT OF CONTACT. i � FlowGua�d Goid ar�BtazeMas6er a�e registered trademarks of Noveon IP Holdings Corp. FGGBM is a trademark of Noveon IF Hddings Corp. �� Hilti. O��erform. Outlast. a 214 Hitd.Inc.(U.S.)1�79-8000•www us.hilti.com•en i espand 1-800-879-5000•Hilti Frestop Systems Guide 2007 - - � ' <� r UL SYSTEM NO:W-L-2186 PLASTIC PIPE THROUGH GYPSUM WALI.ASSEMBLY F-RATING='!-H�t OR 2-HR. � T RATING=1t2-HR OR 1-HR. � L-RATING AT AMBIENT=LESS THAN 1 CFNUSQ.FT. � L-RATING AT 400°F=2 CFM/SQ.FT. ° FRON.�T�V�E�N SEC7'ION A A � A � 1 2 3 ' 4 3 � I A 1.GYPSUM WALL ASSEMBLY(Ul CLASSIFIED U300,U400 OR V400 SERIES)(1-HR.OR 2-HR.FIRE-RA71NG) ��'� �� (2-HR.SHOWN). � � 2.[NOT SHOWN]WOOD STUDS TO CONSIST OF 2"x 4"LUMBER.STEEL STUDS TO BE MIN.2-1l2"V111DE. } 3.[OPTIONALj MAXIMUM 3°NOMINAL DIAMETER STEEL PIPE SLffVE(SCHEDULE 40 OR LtGHTER). 4.MAXiMUM 9"NOMINAL DIAMETER SDR 9 CROSS-LINKED POi.YETHYLENE(PEX)TUBING(CLOSED PIPING SYSTEM). 5.HILTI FS-ONE INTUMESCENT FIRESTOP SEALANT: A.MINIMUM 518"DEPTH,FOR A 1-HR.FIRE-RATING. � : B.MINIMUM 1-114"DEPTH,FOR A 2-HR.FIRE-RATING. �� ���� NOTES: 1.MAXIMUM DIAMETER OF OPENING=3". 2.ANNULAR SPACE=MINI�IUM 112",MAXIMUM 1-3/8". ° 3.WHEN A STEEL SLEEVf IS PROVIDED FOR ASSEMBLIES WITH L-RATINGS,APPLY HiLTi fS-ONE � iNTUMESCENT FIRESTOP SEALANT AR4UND PERlPHERY OF OPENING TO COVER EXPOSED - ENDS OF SLEEVE AND TO LAP MINfMUM 1/4"ONTO GYPSUM BOARD ON EACH SIDE OF WALL 4.WHEN A STEEL SLEEIIE IS NOT PROVIDED,PENETRANT MAY BE INSTALLED AT AN ANGLE NOT GREATER THAN 45°FROM PERPENDICULAR. � , A� Hilti. Outperform. Outlast. FBti,inc. U.S. 1-800-879-8000•www us.hi •en es •Hitti Fresto S �Guide 2007 291 ( ) � panoll-800-879-5000 P ys � � � $ . � UL SYSTEM N0.W-L-2244 PLASTIC PiPE THROUGH GYPSUM WALL ASSEMBLY F-RATING=1 AND 2-HR. o .� T-RATING=1 AND 2-HR. � L-RATING AT AMBIENT=LESS THAN 1 CFM/SQ FT. � L-RATING AT 400°F=2 CFMiS4.FT. �;` FRONT VIEW � SECTION A-A A � 1 2 3 4 5 A � 1.GYPSUM WALL ASSEMBLY(UL CIASSIFIED U300,11400 OR V4�0 SERIES WALL)(1-HR.OR 2-HR. F[RE-RATING�(2-HR.SHOWN). 2.(NOT SHOWN}.WOOD STUDS t0 CONSIST OF NOMtNAl.2"x 4"LUMBER.STEEL STUDS TO BE MINIMUM 2-1t2"iMDE. 3.PENETRATiNG ITEM TO BE ONE OF THE FOLLOWING : A.MAXIMUM 2"NOMfNAL DlAMETER PYC PLASTlC PIPE(5CHEDULE 40 OR HEAVIER} (GELLUl.AR OR SOLID Ct3RE�(CLOSED PIPING SYSTEM ONLI�. B.MAXlMUM 2"NOMINAL DtAMETER CPVC PLASTIC PIP�(SDR 110R SDR 13.5�(CLOSED PIPING SYSTEM ONLY). 4.MINtMUM 5I8"DEPTH HILTf FS-ONE INTUMESCENT FIRESTOP SEALANT. 5.MIN[MUM 1!2"BEAD H[LTI FS-ONE tNTUMESCENT FIRESTOP SEALANT AT POfNT OF CONTACT. � ( NOTES: t.MAXIMUM DIAMETER OF OPENING=3". I 2.ANNULAR SPACE=MINlMUM 0°,MAXIMUM 5I8". i � � i I � i ; _ ' Hilti. ���uerf�rm. Outtast. �''� 292 iHiiti,Inc.(U.S.}1-800-879-5000•rvww us.hilti.com•en espanol 1-800-879-5000•Hiiti Firestop Systems Guide 2007 BXUV.L570-Fire Resistance Ratings-ANSI/UL 263 Page 1 of 6 3I�\��LINE CERTIFt ATIONS 018 T�RY BXUV.L570 Fire Resistance Ratings - ANSI/UL 263 ?a�e_9�om Design/Syrstem/Construct�an/Assembiy Usage Disclaimer • Authortties Having Jurisdiclion 5hould be conwited in at�pses as to the partkular requir�nent5 tovering the it�sWllation and use of UL Listed or Ciassified products,equipment,system,devioes,and materiais. • Authoritles Havi�g lurisdiction shpuld be o�nsulted befor�ro��on. • Fre resistance assembi�and products are devebped by U►e design wbmitter and have been imestlgated by UL for compliance with applicable requiremenCS.The published information canrwt always address every construction nuance encountered in the field. • When field issues arise,it is recommended the first coMact for assistance be the technical service staff providetl by tlie product manutacWrer noted for the design.Users oP flre re�stance assemblies are advised to cpnsult tfie general Guide Ir�formadon for each P�oduct category and each qroup of assembites.7rie Gufde Infortnation includes specif"cs conoeming altemate materiais and altemate methods of co�strudion. • Onfy produds which bear UL's Mark are considered as passified,Llsted,or Recoyn¢ed. ! � Fire Resistance Ratings - ANSI/UL 263 See Gener�l Fnfortnatlon for Fire ResistancP Ran�9e_nNCta u �a� Desiyn No.L570 September 09,2008 I � Unrestrainet!AssembiY Rating—1 Hr. Load itestricDed fw�Canadian Appllcatlons—See C�uide BXUV7 `.,�-d_\ � ,�� �, , � �� � � �` � �� � �� �� � � � �(��..-- ����� ��-��..---`�a I ` _ _r.��-�._ a _�,,.�.. ..�, , .���..�r.� --- �.�r_.� �. I - �/�`�� 1�G�-- G� 7� D CC� � [lM � � � � f ��T 2 1 �nn� I � ' TOWN QF `�I,���_. � � _� �' IL E C OPY http://database.uLcom/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.htmi?name=B... 9/26/2008 BXUV.L570-Fire Resistance Ratings-ANSUUL 263 Page 2 of 6 � � � � � I � � � , I � � � I i i i � � � , i i �- � � 1'AO°ry^g SY�—T��1���9 SYStem shall consist of one of the foliowing: http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=B... 9/26/2008 BXW.L570-Fire Resistance Ratings-ANSUtJL 263 Page 3 of 6 � srscem No.i Subflooriny—fdom 19/32 in.thidc wood stnxtural panels installed perpendicufar to the joisLS with end joints staggered. Plywood or paneis seared to joists wtM corupvctlon adhesive and No.6d�inged shank nails,spaced 12 In.OC abng each joist.Staples having equal or greater withdrawal and lateral resistance strergth may be substituced for the 6d nails. Vapor Barrier—(Optional)-Nom 0.030 in.thick oommercial asphatt saturated feiL Finish floor—Min 1 by 4 in.T&6 fumber installed perpendicular to the jasts,o�min 15/32 In.thidc wood structura� panels,min grede"Unde�faymenY`or'Stngle-Floor".Face grain of plywood or strength azls of panel to be perpendicular tp joists with joints sta99ered. �rstem No.2 �+���p—Nom 19/32 in.thidc wood structural paneis installed perpenditular to the joists with end joints staggered. Plywood or panefs sepired to joists with wnstruction adhesive and No.6d rfnged shank nails,spaced 12 in.OC along each joist.Staples having equal or greater withdrawal and lateral resistance strength may be substituted for the 6d nails. Vapor Barrier—(pptiona�j_Nom p,030 in.[hick commercial asphaft saturaced felt. Floor Mat Naterials•-(Optioeal)—Min 3/8 in.to max 3/4 in.thick Hoor mat material loosely laid over the subfloor. � UNITED STATES GYPSUM CO—LEVF1RpCK�&and Sound Reductio�Board Attemate Floor Mat Maberials�—(Optfonaq-Nom 1/4 in.thick floor mat material loosely laid over the subFloor. UNI7'ED STATE.S G1rp�M CO—LEVELRpp(�g�nd Ftoor Underlayment SRM-25 �^ate F1oor Mat Mate�ials*—(Optio�al)-Nom 3/8 in.thidc floor mat material loosely�aid over the subfioor. SOLtlTIA INC—Type SC50 i � �^�h�O�^9'��ToPP�����rc"—Mi�1/2 in,thickness of floor bo�fng mixture having a min compressive strength of 1200 psi.Refer to manufacivrers instructions accompanying tl�e materiai for specific mbc design. UNITED STATES GYPStlM CO—Type LRK iSYstee+No.3 ` Subfloarcinp—Nom 19/32 in.thidc wood�uryi panels instalied perpend(qilar to the joists with end joint5 staggered. PlYwood or panels secured to joists with coru�ction adhesive and No.6d ringed shank nails,spaced 12 in.OC abng each )oist.Staples having equal or greater withdrawal and lateral resistance strengtfi may be wbstituted for the 6d nails. Yapor Barrier—(Optionaq-Nom 0.03U fn.thick commercial asphalt saturated felt. � Pbor Mat Mabarials#—(Optipnal)-Min 3/8 in.to max 3/4 in.thick floor mat materiai loosely laid over the subfloor. UNITED STATES GYPSUM CO—LEVElRpCK�Brand Sound Reducdon Board N��ternate Roor Mat Maberials'�—(Optionaq-Nom i/4 in.thick floor mat material fooseiy Iaid over the subHoor. UNITED STATES GYPSUM CO—LE{/ELROCK�Brend FFoor Underlayme�t SRM-25 I ( INben+ate Flaor Mat Materials*—(Optional)-Nom 3/8 in.thidc fbor mat material loosely laid over the subFloor. SOLUTIA INC—Type SC50 ( Fi�ish F�oorin�-Hoor Topping Miuture*—Min 1/2 in.thickness of Floor toppin9 mixture having a min compressive strength of 3000 psi.Refer to manufacturers instructions accompanyfng the materiai for specific mix design. � UNITED STATES GYPSUM CO—Type HSLRK http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=B... 9/26/2008 � BXUV.L570-Fire Resistance Ratings-ANSI/UL 263 Page 4 of 6 � System No.4 5ubflooriny—Nom 19/32 in.thidc wood strvctural panels installed peryendicular to the joists wRh end joints staggered. Plywood or panels secvred to/oists wiM cor�structio�adhesive and No.6d ringed shank nails,spaced 12 in.OC abng each joist.Staples havtng equai or greater withdrewal and lateral resisqnce screngtfi may be wbsUtuted for the 6d nails. Vapor Barrier-(pptrona�)—Nom 0.030 in.thick commerciat asphait saturated felt Finish Flooring-Ftoor Toppinp yixtures—Mtn 3/4 or 1 in.thidmess of Aoor Wpping mixture for 19/32 or 15/32 in. th�dc wood sWCWraI panels re5pettiveiy,having a min wmpressive strength of 1000 psi.Refer to manufaUurePs instructlons accompanying the material for specific mix design. ALLIED CUSTOM C,YPSIJt�1 pLASTERyyORKS LLC—Accu-Crete and Aau-Radient Mbernate Floor Mat Maberiaix—(ppnp��)-Floor mat material nominal 2-9,5 mm thick bose laid over the subfloor. Floor topping shail be a min of 3/4 in.or i In.thitk for 14/32 or 15/32 in.thidc wood strvctural panels respecitively. ALLIED CUSTOM GYPSUM PLASTERWORKS LLC—Type AccuQuiet P80,Type AccuQuiet C40,Type AccuQuiet RSM 20, Type AcwQuiet RSM 32,Type AccuQufet RSM 48,Type AauQuiet RSM 64,and Type AccuQuiet RSM 120 SYstem No.5 �+ct�ra�Cement-Fiber Un1ts*—Nom 3/4 in.#hick,with tong edges tpngue and grooved.Long dimension of panels W be perpendicuiar to joi�with end joints sqggered a min oF 2 ft and centered over the joists.Panels secured to�ists witry 1-5/8 in.bng No.8 self-drilling,self-cpuntersink(ng steel screws spacetf a max of 12 in.OC in the fieid with a screw located 1 i�.arul 2 in.from each edye�and 8 in.OC on the perimeter with a screw located 2 in.from each edge,located 1/2 in.from the sFde edges of the panel. UNITED STATES GYPSUM CO—FORTACRETE Structural panels � 2•�+re�M�ood Membe►s*—Min 9-1/2 in.deep"I'shaped wood joists spaced at a max of 19.2 in.OC,and blodced at the ends usir►g 2 in.by 10 in.wood m�nbers.Min joists beariog on piates�all be 5-1/2 i�.loists sewred to the bearing plates with two 8d or lOd nails at each end.Spaang may be tncreased to 24 in.OC when Batts and Biankets'�(Item 38) is used. YVE1fERNAEUSER—Types T7I�36p,17I�560,TJI�/L65,TJI�/L90,TJI�/H90,77I�/HD90,T7I�/HS90,T7I�100C, TJIm 300C. � ������+�+�e�Wood Memberss—Min 14 in.deep wood and steel trusses spaced a max of 19.2 in.OC.Min bearing and nailing or boldng to bearing plates(tfirough steN bearing d(ps)shall be in acoordance witl�the manufacturer's � instaltation instructions.Spacing may be increased tp 24 in.OC when Batts and Blankets*(Item 3B)Is used. WEYERNAEUSER—Types TJH,T)L(X),T]M,T]S,T]W,TJL. 3.Insulation-Batts and Btankets#—(Optlonal)—Glass Rber insulatfon,secured to the wbflooring with staples,or to the wood joists with 0.090 in,diam gaiv�eel wires,or draped over the resilient channel/gypsum panel(or Steel Framing MernbersJgypsum paneQ ceiling membrane.My thidcness of glass fiber insulation bea�ing the UL passiticaUon Marking as to Surface Buming Charecteristics and/or Fre Resista�ce. 3A•Insu(ab°�"Loose F'il�Naterial*—As an aitemate to Item 3—Any thkkness of loose fill material bearing the UL Classification Marking for Surface Buming Charac[erist��applied within the conceated space,over the resiNent or furring ���/9YP5�Panet or Steei Freming Members/gypsum panei ceiling membrene. 3g•L�suletio�-Batts and Biankets*—(For Use When Structy�al Wood Members=are spaced 24 in OCj—MIn. 1 in. thidc glass fiber insulation bearing tlie UL Classificatlon Marking as to Surface Bumi�Characteristics and/or Fire - R�� �� channel/gypsum panel(or Steel Fra ' -��p�T • Rm�,zsT�.� .���� � � � 4•ResiFient Channds—Nom 1/2 in.dee I 0.020 in.thick galv steel.Installed p�'Z-3/8 In.wide at the base and i-3/8 i�.wide at the face,formed from � ���'� perpendiwlar to the foists,spaced a max of 16 in.OC when rro insulatfon is fitted in the space,or 12 i�.OC when insulatipn is fitted in the cpncealed space.Two courses of resilient channel po5itioned 6 %� in.OC at gypsum panet butt-joints(3 in.from each end of wailboarcl).Chartnels oriented opposfte at gypsum panel butt- 1 joints.Channel splices ove�lapped 4 irt.beneath wood trusses.Channels secured to each truss with 1-1/4 in.bng Type S � screws. � I ; i � � , 4A.Alternabe Steet F�ami�y�y�y�_�ryot Shown)-As an altemate to Item 4,main runners,cross tees,cross � channels and wall angie as listed below. . 1 _ _�. I _ _.__.. __.._.._. _..,_ i . __.___..__ __ __._.__. � - _ � http://database.u(.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=B... 9/26/2008 � BXUV.L570-Fire Resistance Ratings-ANSI/UL 263 Page 5 of 6 • �.._ a.Main Runners—Nom 10 or 12 R long,15/16 in.or 1-1/2 in.wide face,spaced 4 R.OC.Maln ru�ners suspended by min 12 SWG galv steel hanger wires spaced 48 in.OC.Hanger wires to be located adjacent to main runner/cross tee intersections.Hanger wirPS wrapped and twist-tied on 16d nails driven in to side of joists at teast 5 in.above the bottom face. 4 ` b.Cross Tees—Nom 4 ft long,1-i/2 in.wide face,installed perpendicular to the main runners, spaced 16 in.OC.Additional cross tees or cross channels used at 8 in.from each side of butted 9ypsum panel end joints.The cross tees or cross cha�nels may be riveted or screw attached to the ' wall angle or channel to facilitate the ceiling installation. c.Cross Channels—Nom 4 or 12 ft long,instailed perpendicular to main runners,spaced 16 in. OC.When Batts and Blankets(I[em 5)are used,cross channels spaced 16 i�.OC. � d.Wall Angle or Channel—Painted or galv steel angle with 1 in.legs or channel with 1 in.legs, 1-9/16 in.deep attached to walls at perimeter of ceiling with fasteners 16 in.OC.To support steel ,' frami�g member ends and for screw-attachment of the gypsum panels. ? __ _ . _. __ i � � CGC INC—Type DGL or RX, USG INTERIORS INC—Type DGL or RX. ` 4g•A�temate Steel Framing Members—(Not Shown)*—As an altemate to Items 4 and 4A,furring channels and Steel Framing Members as described below. a.Furring Cha�nefs—Fortned of No.25 MSG galv steel.2-3/8 in.wide by 7/8 in.deep,spaced 24 in.OC,perpendicvlar to joists.When insulation,ltems 3,3A,or 36 is used,the furring channel spacing shail be reduced to 16 in.OC.Channels secured to joists as described in Item b.Ends of adjoining Channels overlapped 6 in.and ded together with double strand of No. 18 SWG galv steel wire near each end of overiap. b.Steei Framing Members*—Used to attach furring channels(Item a)to the wood joists(Item 2).When wood joists are spaced 19.2 in.OC,clips spaced a max of 38.4 in.OC.When wood joists are spaced 16 or 24 in.OC,clips spaced a max of 48 in.OC.RSIC-1 Gips secured to alternating � joists with No.8 x 2-1/2 in.coarse drywall screw through the center grommet.RSIC-V clips secured to altemating joist5 with No.8 x 1-1/2 in.coarse drywall screw through the center hole.Furring channels are friction fitted into dips.Adjoining channels are overlapped as described in Item a.As an altemate,ends of adjoining channels may be overlapped 6 in.and secured together with two self-tapping#6 framing screws,min.7/16 in.long at the midpoint of the overlap,with one screw on each Flange of the channel.Additional clips required to hold furring channel that supports the wallboard butt joints,as dpscribed in Item 5. PAC INTERNATIONAL INC—Types R$IC-1,RSIC-V. 4C.Stee1 Framing Members*—(Optional,Not Shown)-Used as an altemate method to attach min.1/2 in.deep resilient channels(Item 4)to structurel wood members(Item 2).Resilient channels are friction fitted into dips,and then dips are secured to the bottom chord of each structural wood member with a min. 1-3/4 in.long Type S steel screw through the center hole of the ciip and the resilient channel Flange.Adjoining resilient channels are overlapped 4 in.under strudural wood members.The Gip flange is opened slighUy to accommodate the two overlapped channels.Additionai Gips required to hold resilient channel that supports Lhe gypsum board butt joints,as described in Item 5. KEENE BUILDING PRODUCTS CO INC—Type RC Assurance. 5.Gypsum Board*—Two layers of 1/2 in.or 5/8 in.thidc by 4 ft wide gypsum panels,installed perpendicular to resilient channeis(Item 4).The base layer of panels screw-attathed to the resilient channeis with 1 in.long Type S screws spaced 8 in.OC at the butt joints and 16 in.OC in the field of the panel.The face layer screw-attached co the resilient channels with ' 1-5/8 in.Type 5 screws spaced 8 in.OC and 1-1/2 in.Type G screws spaced 8 in.OC at the butt joints located mid-span between resilient channels.When Steel Framing Members(Item 4A)are used,gypsum board installed with long dimension perpendicular to cross tees.The base layer of panels fastened to cross tees with 1 in.long Type S screws spaced 8 in.OC at the butt joints a�d 16 in.OC in the field of the panel.The face layer screw-attached to the cross tees with 1-5/8 in.Type S screws spaced 8 in.06 and i-1/2 in.Type G screws spaced 8 in.OC at the butt joinks located mid-span between cross tees.Screws along sides and ends of panels spaced 3/8 to 1/2 in.from panel edge.End joints of panels shall be staggered with spacin9 between joints on adjacent panels not less than 4 ft OC.When Steel Framing Members(Item 46) are used,panels installed with long dimension parallel with joists.Base layer attached to the furring channels using 1 in. � long Type 5 bugle-head steel screws spaced 8 in.OC along butted end joints and 12 in.OC in the fieid of the panels.Butted end joints shall be staggered min.2 ft.within the assembly,and occur midway belween the continuous furring channels. Each end of the gypsum panels shali be supported by a single tength of furring channel equal to the width of the panel plus 6 in.on each end.The fumng channeis shall be spaced approximately 3-1/2 in.OC,and be attached to underside of the joist with one RSIC-1 clip at each end of the channei.Butted base layer end joints to be offset a minimum of 24 in.in adjacent courses.Outer layer attached to the furring channels using i-5/8 in.long Type S bugle-head steei screws spaced � 8 in.OC at butted joincs and 12 in.OC in the field.Butted end joints to be offset min 12 in.from base layer end joints. Bucted side joints of outer layer to be offset min 12 in.from butted side joints of base layer. http://database.ul.comlcgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=B... 9/26/2008 - BXUV.L570-Fire Resistance Ratings-ANSUUL 263 Page 6 of 6 � CANADIAN 6YPSUM COMPANY—1/2 in.Type C,IP-X2,IPC-AR;5/8 in.Type C,SCX,IP-X3,IP-X2. UNITED STATES GYpSU�y Cp—1/Z in.Type C,IP-X2,IPC-AR;5/8 in.Type C,SCX,IP-Xi,IP-X2. USG MEXICO 5 A dE C V—1/2 in.Type C,IP-X2,IPC-AR;5/8 in.Type C,SCX,IP-Xi,IP-X2. 6•Rnishiny Systeen—Fiber tape�nbedded in oompound o�er joints and exposed nail heads,covered with cornpound with edges of compound feathered out.As an alternate,nom 3/32 in.thidc gypsum veneer plaster may be applied to the entfre surtace of classified verreer baseboard.loints reinforced. *Bearing the UL Gassification Mark Last Uodated on 20�8-09-09 _T �..,,� _._._. �..____�.__ __. _..._.�__.__ � Questio�s? Notice of Disdaim r Page Too CoRyright�2nnR Underwriters Laboratori�In�� The appearance of a company's name or product in this database dces not in itseff assure that producGs so identified have been manufactured under UL's Follow-Up Seroice.Only those products bear(�g the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service.Always look for the Mark on the produd. UL permits the reprodudion of the material cnntained in the Oniine Certificatio�Direccory subject to the folbwing conditions: 1.The Guide Infortnatlon,Designs and/or listings(files)must be presented in their entlrety and in a non-misFeading manner,without any manipulation of the data(o�drawings).2.The state�nent'Reprinted from the Online Certifications D(rectory with pertnission from Underwriters Laboratories Inc."must appear adjacent to the extrac[ed material.In addition,the reprinted material must indude a copyright notice in the foibwing fottnat:'Copyright p 2008 Underwriters Laboretories Inc,�• � An +ngepeaoerti orpanization w�rkinQ for a safer world rrish,integttty< precisiun end knore6edqa. � � � i I i ( i ( i � http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAMElshowpage.html?name=B... 9/26/2008 � dJ � i a�� I HR. FIRE RATING UL/aSTM �63, a55EMBLY L5'f0 I HR. P1RE RATIN6 UL/ASTM �63, ?�SS�MBLY L5'10 PINISH FL04R PER DE5IGNER �" PLYWOOD 9" DI�4. DUGTING PER MEGH. FIRE DAMPERS AT PENETRATIONS �O" TJL G�4�1 LI6HT PER DE516NER W/ TENMAT FIRE RA'T�D GOVER RE5ILIEAIT Gh!?�N1�tEL fb" OG � LAYERS �" T'YPE X 6YP. BD. FINISH PLOOR PER DESIGNER �" PLYWC�OD �O" TJL RESILIENT GHANAtEL I6" OG � LA'f�R5 �" TYI''E X GYP. BI�. 4" DIA. DUGTING PER NIEGH. P�i?E D�4MPER5 AT P�NETRf+�TIONS GAN LI6HT P�R DE5IGNER W/ TENMAT PIRE R,4TED GOVER . � , . � � _ _ � � � � � V � D � � � , . T�3WN���AI� � TOWI�_OF_VAIL___�__, Department ofCommunity Deve%pment Building Safety and Inspection Services i 75 South Frontage Road � �ail, Co%ado 81657 ��, 970-479-2138 FAX 970-479-2452 www,vailgov,com Second Check Second check plan review comments are shown below original comment in bo/d ita/ics BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: plans submitted 5/1/08 TO: Contractor/Applicant Architect Highland Builders Fritrlen Pierce Mark Hallenbeck proj#0721 FAX/Email #: mark@highlandbuilders.com johlson@vailarchitects.com NUMBER OF PAGES: 3 FROM: Chris Gunion, Building Plans Examiner DATE: 5/1/08 BUILDING PERMIT #: B08-0072 OWNERS NAME: Jeff Selby SITE ADDRESS: 288 Bridge Street OCCUPANCY GROUP: mixed TYPE OF CONSTRUCTION: VA NUMBER OF STORIES: 3 BUILDING AREA: 7870 s.f. The documents submitted for this project dated 4/28/08 have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit: For processing: . Please submit four complete sets of revised construction documents containing the requested information with all plan revision items clouded or otherwise identified. Partial plan sets or loose �lan sheets are not accepted. • Please respond in writing to each comment by markinq the attached list or creating a response letter. Indicate which �lan sheet, detail, specification, or calculation shows the requested information. Please send revisions to the attention of the plans examiner with the buildina permit application number noted. . Please be sure to include on the resubmittal the e�ineer's or architect's "wet"stamp, siqnature, registration number and date on the cover page of any structural calculations, all structural a � details and structural sheets of the plans. For commercial or multi-family projects all sheets of the plans must be stamped. Please coordinate plan resubmittal with Town of Vail Public Works, Planning and Fire Department comments. Inc/ude requested information addressing Scot Hunn's comment: ' "Deve%per sha//address p/anning condition of approva/concerning submitta/of executed encroachment, shoring and temporary access agreements with adjacent �, property owners PRIOR to issuance of a bui/ding permit." As of 5/I/08, approva/s from Town of Vai/Pub/ic Works and Vai/Fire have not been entered in Permits+ for this bui/ding permit. Architectural Comments: 1 Sheet A000 indicates the building construction type is type VA, the code review sheet X001 indicates VB is proposed. Coordinate all notes on plans. Show the appropriate 1 hour ratings in the code tab/e X001"rating requirements of bui/ding e%ments"See XOOi 3 If type VA construction is used for the proposed building, include complete 1 hour assembly details for roof/ceiling, floor/ceiling columns and beams per IBC table 601. Include all fire resistive assembly listing details. If VB construction is used, include 1 hour construction details only where required for separated uses, and location of property, decks and parapets. Coordinate 1 hour assemb/y/istings with a//section detai/s on the p/ans P/an sections and detai/s contain information conf/icting with the assemb/y/istings Reference a//1 hour assemb/y detai/s on the p/ans and sections detai/s Provide the UL orgypsum assemb/y detai/on the stamped p/an sheets Mu/tip/e sheets Inc/ude assemb/y detai/for 1 hour roof construction, Coordinate with a//p/an sections and detai/s Mu/tip/e sheets See Sheet A804 for fire ratings. � Revise occupant load for first story M occupancy. X001 indicates occupant load factor is 100. This is incorrect. The occupant load factor is 30. IBC table 1004.1.2. Revise exit plans. Update a//occupant/oads on 2/X001 to show the correct occupant/oads See X001 6 Revise sheet X001 to show complete exit discharge to the public way at all east exit discharge locations. Provide complete plans and documentation for the east exit discharge at the"access agreement easement". Include details on a code compliant exit discharge per IBC ch. 10. Include documentation on exit discharge easement and show complete plan for exit discharge to the public way. P/ease inc/ude a copy of the requested exit easement for the bui/ding permit record, Document was not inc/uded. See attached document �1 Include a complete Statement of special inspection with all required information per IBC 1704.1.1. No statement was received with the revised p/ans See IBC 1704,1,1 for the required information to be provided. See the/ist of required specia/inspections on sheet 51 See revise Cover Sheet A000 � Revise roof plan and elevations to show new boiler vents and termination 2' above any roof within 10" per and 8'from a vertical wall per IFGC 503.6.5 No response was given to this comment. Show information on the roof p/ans See updated sheet A301 and A204 14 Provide fixed ladders, catwalks and working platforms for access to all rooftop equipment per IMC 306.5. Provide access to elevator equipment room per requirements of NWCCOG elevator inspector. o - �Sfiow Fxed/adders providing access to the roof and equipment from grade per IMC 306,5 See updated sheet A204 Electrical Comments: 33 Provide emergency egress illumination where for exterior stairs where two exits are required. No response was received 34 Provide receptacles above Show Window per NEC 210.62. No response was received 35 Provide separate branch circuits for elevator machine room and pit receptacles per NEC 620.23. No response was received 36 Location of 20hp elevator motor disconnect is not shown. No response was received Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. F:\cdev\CHRIS\PERMIT.COMMENTS\B07-0307\607-0307.DOC �i � I � ���� �� � Depaitment of Community Deve%pment Building Safety and Inspection Sen�ices 75 South Frontage Road �ail, Co%ado 81657 970-479-Z138 FAX 970-479-Z45Z www.vailgov.com Second Check Second check plan review comments are shown below original comment in bo/d ita/ics BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: plans submitted 5/1/08 TO: Contractor/A�plicant Architect Highland Builders Fritzlen Pierce Mark Hallenbeck proj#0721 FAX/Email #: mark@highlandbuilders.com johlson@vailarchitects.com NUMBER OF PAGES: 3 FROM: Chris Gunion, Building Plans Examiner DATE: 5/1/08 BUILDING PERMIT #: B08-0072 OWNERS NAME: Jeff Selby SITE ADDRESS: 288 Bridge Street OCCUPANCY GROUP: mixed TYPE OF CONSTRUCTION: VA NUMBER OF STORIES: 3 BUILDING AREA: 7870 s.f. The documents submitted for this project dated 4/28/08 have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit: For processing: • Please submit four complete sets of revised construction documents containinq the requested information with all plan revision items clouded or otherwise identified. Partial plan sets or loose plan sheets are not accepted. . Please respond in writinq to each comment b�marking the attached list or creatinq a response letter Indicate which plan sheet detail specification or calculation shows the requested information Please send revisions to the attention of the plans examiner with the buildina permit a�plication number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, siqnature, registration number and date on the cover �aqe of any structura� calculations, all structural . - I details and structural sheets of the plans. For commercial or multi-family,projects all sheets of I� the plans must be stamped. Please coordinate plan resubmittal with Town of Vail Public Works, Planning and Fire Department comments. Indude requested information addressing Scot Hunn's comment: "Deve%per sha//address p/anning rnndition of approva/concerning submitta/of executed encroachment, sho�ing and temporary access agreements with adjacent property owners PRIOR to issuance of a bui/ding permit," As of 5/1/08, approva/s from Town of Vai/Pub/ic Works and Vai/Fire have not been entered in Permits+ for this bui/ding permit. Architectural Comments: 1 Sheet A000 indicates the building construction rype is type VA, the code review sheet X001 indicates VB is proposed. Coordinate all notes on plans. Show the appropriate 1 hour ratings in the code tab/e XOOZ"rating requirements of bui/ding e%ments" 3 If type VA construction is used for the proposed building, include complete 1 hour assembly details for roof/ceiling, floor/ceiling columns and beams per IBC table 601. Include all fire resistive assembly listing details. If VB construction is used, include 1 hour construction details only where required for separated uses, and location of property, decks and parapets. Coordinate 1 hour assemb/y/istings with a//section detai/s on the p/ans P/an sections and detai/s contain information conf/icting with the assemb/y/istings Reference a//1 hour assemb/y detai/s on the p/ans and sections detai/s Provide the UL orgypsum assei»b/y detai/on the stamped p/an sheets: Mu/tip/e sheets Inc/ude assemb/y detai/for 1 hour roof construction. Coordinate with a//p/an sections and detai/s Mu/tip/e sheets 5 Revise occupant load for first story M occupancy. X001 indicates occupant load factor is 100. This is incorrect. The occupant load factor is 30. IBC table 1004.1.2. Revise exit plans. Update a//occupant/oads on 2/XO01 to show the correct occupant/oads 6 Revise sheet X001 to show complete exit discharge to the public way at all east exit discharge locations. Provide complete plans and documentation for the east exit discharge at the "access agreement easement". Include details on a code compliant exit discharge per IBC ch. 10. Include documentation on exit discharge easement and show complete plan for exit discharge to the public way. P/ease inc/ude a copy of the requested exit easement for the bui/ding permit record. , Docament was not inc/uded. 11 Include a complete Statement of special inspection with all required information per IBC 1704.1.1. No statement was receiveal with the revised p/ans See IBC 1704.Z,Z for the required information to be provided. See the/ist of required specia/inspections on sheet SI 12 Revise roof plan and elevations to show new boiler vents and termination 2' above any roof within 10" per and 8'from a vertical wall per IFGC 503.6.5 No response was given to this comment, Show information on the roof p/ans 14 Provide fixed ladders, catwalks and working platforms for access to all rooftop equipment per IMC 306.5. Provide access to elevator equipment room per requirements of NWCCOG elevator inspector. Show fixed/adders providing access to the roof and equipment from grade per IMC 306.5 Electrical Comments: 33 Provide emergency egress illumination where for e�erior stairs where two exits are required. No response was received 34 Provide receptacles above Show Window per NEC 210.62. No response was received 35 Provide separate branch circuits for elevator machine room and pit receptacles per NEC 620.23. No response was received 36 Location of 20hp elevator motor disconnect is not shown. No response was received Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0072\608-0072.secondcheckDOC.DOC � ; FtL E COP Y TOwN OF VAI� ; Department of Community Development 75 South Frontage Road i/ail, Colorado 81657 970-479-2138 February 27, 2009 FAX 970-479-2452 www.vailgov.com Honorable Mayor Dick Cleveland Inter-office mail Re: Rucksack construction project building permit number B08-0072 located at 288 Bridge Street Lots C&D, Block 5A, Vail Village Filing 1 Mr. Mayor, The following summary is in response to your request on information in regards to the recent events that have occurred at the Rucksack construction site. Snow removal from the Rucksack building onto the A&D Building Bob Webb, Code enforcement officer, was contacted by Susan Jasem at 8:00 am on February 25th, 2009 registering a complaint as to person(s) from the Rucksack building were dumping snow onto the roof of the A&D building next door. This complaint was forwarded to Leonard Sandoval of the public works department. Upon visiting the site it was determined that the snow was removed to repair a section of roof flashing. Approval of drainage from the Rucksack building onto the A8�D building The approved plans for this construction project did not include approval of drainage to be taken from the Rucksack building to the A&D building. The contractor, however, has run a drainage pipe from a 9 square foot roof area into the A&D building gutter. I have contacted the Rucksack building owner who indicated he will have the drain rerouted to an approved location within the Rucksack drainage system. A building inspection shall be performed to insure that this does take place. Egress from the second floor window of the A&D building An 18 inch passageway for the second floor window to grade was constructed by the Rucksack contractor as per an agreement with the A&D building owners. This passageway is not a building/fire code requirement, therefore was not considered as part of the building permit approval process. Chief McGee and I on Wednesday visited the site to become familiar with what has been done in regards to this passageway and we have concluded that it is an attractive nuisance. The design professional for the project will be required to provide a solution to remove the nuisance that will be acceptable to the Building and Fire Investigation teams. . ��� RECYCLED PAPER �. � � u;.,, ;� , .�.� {F � ♦i 4. ; � , ... Action taken '� e� ` � `' "'Y � � I have scheduled a meeting with the Rucksack construction team and inviting representatives of the A&D building to discuss these aforementioned items as well as a concern by the public works department in regards to the roof drainage from the A&D building that prior to the recent construction drained on the Rucksack property. This meeting is tentatively scheduled for next Friday March 6tn 2009. If I can be of any further assistance please contact me at 479-2142 Sincerely, , � f� ---_, Martin Haeberle Chief Building Official Cc: Stan Zemler, Town Manager George Ruther, Community Development Director Mike McGee, Deputy Fire Chief File � � � � '�OY���ZUPS��..O1(�fi+C�O' . COUNCII OF GOVFiRNMENTS`�``�� '���_��._����-- �-c, � M (� To: Martin Haeberle Town of Vail Building Official D � FEB 12 ! From: Steve Allen, Elevator Inspector (j� 1009 i I u � 970-468-0295 ext. 108 or elevator nwc.coa.co.us TOWN OF VAIL Dabe: 02/11/09 i Project Name: Highland Builders Corp. � � ❑ Conveyance Plan Review �] Conveyance Test and Inspection ��Wt� O� V�Bi� � � Location: 288 Bridge Street, Vail, CO 1� � � A ������� � _ _ _ ��Pl� Permit Number: NWCCOG 08-205 -� Conveyance Type: Commercial LULA ❑ The plans; have been reviewed and found to conform to all applicable ASME 17.1 and IBC codes � The rated speed of the conveyance meets ASME A17.1 requirements, speed in up direction 30 FPM, speed in down direction 30 FPM �1 The Conveyance at the above location was inspected and tested on 02/10/2009 and a: ❑ TEMPORARY Certificate; has been issued. � FINAL Inspection Certificate; has been issued. ❑ NO certificate; is being issued. ❑ FOR CONSTRUCTION USE ONLY Comments: Signature Northwest Colorado Council of Governments ♦ PO Box 2308 ♦ Silverthorne ♦ CO ♦ 80498 970-468-0295 ♦ Fax 970-46&1208 ♦ wvvvv.nwc.cog.co.us May. 29. 2008 9:40AM CARI �N CARLSON & DUNKELMAN No. 4893 P. 1 B�$ ,Oc�� �— � � � � o � � ' � D � AY 29 2008 286 BRYD�E ST�ET,INC. i t � �` �� ��= vA!L ��►9,2oos -�o���s+ 2�����\� Mr. Mark Hallenbeck -�� 5-�1 _ 6 2 3�( � �Tighland Builders 2598 Palmer Park Blvd. ��g - oo�t � Colorado Spriz�gs,CO 8c 09 Mark: 286 Bridgc Street,Inc. a:proves the following Staging Agreement: 1) Hig�iland Buildf;rs Corp. will provide a 4'-0 access to all commercial and resid�ential tena•+s, in�vit,ecs and licensees at the A&D Buiiding,286 Bridge Stxeet,Vail,C( '"A�D Building)at all ti.mes during the constructi n. 2) If any damage� curs to A 8�D Building prope,rt�y or the property of A&D tenant during tt construction/staging process,Highland Builders 1 be held liable and High nd Builders will indemnify the damaged party. �ii and Build�rs wiu li; le and will indcmtiify and hold harmless 286 Bridge Strcet, Inc. for any per nai injuries that m,ay occur in the staging azca durin the conslruction. �: ..�hiand Buildcrs shsll also list 286 Bridge Street Inc. a co- insured on its b �lders risk insurance policy. 3) AlI conditions c staging will be approved by the Tovvn of Vail aad Fire Y7epartment for ._1 emerge�ac�exits. � 4) No overnight st3ging. Staging will be used fdr only temporary drop o and deiivery to the�iridge S�Building. No construction shall occur in th staging area. 5) Staging will on] occur ttu�ough Septembcr 1,2Q08. 6) 4' tall traffic ba cade�wilI be placed 4' from the A&D Building. � 7) North Bast corn trae will be remo�'e and replac�d at n4 expense to 286 Bridge Street,v . by the same type of tree and a tree of equal or� r size. $) Highland Build� s Corp. shall be a1lor�ved to constntct or�modify the llowing items which are :t forth oz�tho building permit set of plans. a) A gate betw �n the A&cT7 Building aud the$urton Snowboazd Sh p. b) The gnttets �d downspouts on the ABcD Building which eurrentl flovv unta the roo �f the Burton Snowboard Shop. c) A bathroom�vent on tho A&D Building, ; May, 29. 2008 9:40AM CARI �ON CARLSON & DUNKELMAN No. 4893 P. 2 d) A xeductiu�in lengtl�of a stone wa11 up to 4 feet in Iength loca d on the southeast ;orner of the AcS�D Building. 9) �Tighland Builclers agrees to discuss vvith 286 Bridge Street,Inc.th most efficient mann r,r to a,ccomplish the matters set forth in paragraph 8 erein. ' 10)1'he parties wi 1( first attempt to agree on a redesign in r�vhich the ex' ting exit . will appear to c lisappear into the existing building. If an Agreement cannot be reach on tlus r:design,owner agrees to relocate the exit to the back f the buiiding. By: 286�ridge Str�et,Inc. �ighland Builders - �� ' i �y- jZn hrA,t.�a :ti. c���� y: Mark�Tallez�beck,Highlan Btu A;rnQu- t� i:�ict r�bR p�stu���;R 5'� 'L!-0�G � 124'i P.+� M�i" r T.Boyle Engineering,Inc. 1650 Fallridge Road,Unit G2 Vail,Colorado 81657 � � � 970/476-2170 FAX 970/476-4383 � � Februaiy 3,2009 �/ Kurt Reyna Fritzlen Pierce Architects 1650 Fallridge Road Unit Gl Vail,Colorado 81657 Subject: Penetradons in Ritz-Carlton Office Roof Beams Bridge Street Building Remodel 288 Bridge Street Vail,Colorado Dear Kurt: � This is to address the penetrations in the roof beams over the Ritz-Carlton Sales Office at the Bridge Street Remodel for Greg Denka at the Town of VaiL ' I have reviewed the holes that have been made in both the gluelam ridge beam and the gluelam valley beams in this area. I have determined that the penetrations in the ridge beam have been made according to the detail that was provided by this office,and they meet my approval. Furthermore,I approve of the penetrations that have been made in the north valley beam. However,one condition exists in the south valley beam that will require reinforcing the beam. Two holes were drilled adjacent to each other ' and one more was drilled above these at approximately the mid-span location of this valley beam. This combinarion ', of penetra6ons has reduced the capacity of this beam ' Strap ties should be added to the lower portion of tlus beam to compensate for this reduction in capacity. Two MSTA36 strap ties should be installed on the bottom of this beam, with 18" of these straps on each side of the damaged azea. Furthermore, one addirional MSTA36 strap tie should be added on each side of this beam in the lower 6"of the beam face. Again,these should be installed so that 18"of strap is on each side of the hole location. The addition of these strap des should restore the capacity of this beam to the required strength. Please give me a ' call if you have any qu ' � nts on these items. �a4,.....SjF Sin ere ours, �,�.•��C�F('•9c�'p ' O '� . r. • • g � . T. E , . 4 .� T' thy M.Boyl � Presiden �FS••••••••���� 5101�A� . • . � / .�\'7 � . ,��� p � � �., T.Boyle Engineering,Inc. 1650 Fallridge Road,Unit C-2 Vail,Colorado 81657 : 970/476-2170 FAX 970/476-4383 November 26,2008 Kurt Reyna Fritzlen Pierce Archifects 1650 Fallridge Road Unit C-1 , D � � � � �n � Vail,Colorado 81657 �� Subject: Various Framing Items � 26 M1no Bridge Street Building Remodel �uUO 288 Bridge Street Vail,Colorado T4WN OF VAIL Deaz Kurt: This is to address a few framing items at the Bridge Street Remodel that require clarification for Greg Denka at the Town of Vail. T'hree of the items aze components of the flat roof framing over the Ritz Carlton Sales Of�'ice Conference Robm. The east end of this roof was framed with 1 '/, x 14 LVL lookouts to create a roof overhang in lieu of the rafter layout originally shown on Sheet S4. I have reviewed the lookouts and their•attachment to the supporting beam and approve of them as installed. I also reviewed the parallam header over the opening in this east wall and deternuned that it can support the new loading from the lookout rafters. The third item I reviewed in tlus area was the attaclunent of the double 1 '/.x 14 LVL ledger to the existing building wall framing. I have deternuned that additional lag screws should be installed in tlus ledger. Four'/:"diameter x 7" lag screws should be installed into each existing stud adjacent to the ledger. Greg requested that the cantilevered beam that supports the southwest portion of the exterior Second I.evel deck over the stairs be chamfered to provide minimum code head clearance. The wood portion of this beam is a cosmeric wrap over a Wi0x22 steel beam. Therefore,it may be chamfered as needed without affecting the structural capacity of the cantilever. Greg also wanted documentation on the steel header beam that supports the Third Level interior joists over the � Second Level south wall. A W8x18 was installed at this location to replace the e�cisting 14"steel beam in order to _ provide adequate height for the windows in this wall. I sized this beam to be a simple header over the window openings and this south exterior wall became a bearing wall. This change was made during the conslruction stage,so I had to review the W 18x35 beam in the Second Level floor framing below this wall for the additional loading. I determined that the W 18x35 could not support the additional load. Therefore,I designed a solurion in which we added an MC12x31 chanael to the side of the beam to increase its capacity. This modification is documented on SK-2,dated June 12,2008. � ' The last item that Greg Denka requested I address as of today is the double LVL header over the interior stairway up to the residential storage area. This header spans approximately 3'-6"over the stairs and supports the floor framing above. It extends 2'—3'beyond the stair span on both ends,where it rests on a shzd bearing wall. Four holes have ; been made through the portion of this header resting on the bearing wall at the north end. This portion of the member works like a rim board or blocking. It essentially transfers load from studs above to studs below. As such, the penetrations have not affected its abiliry to transfer those loads. I hereby approve of this header as framed. , Page 2 • Mr.Kurt Reyna November 26,2008 Finally,there is one more framing modification that will be made shortly and requires documentation for the Town of Vail. The bearing wall that supports the sloped 2x12 rafters over the Ritz Carlton Sale Of�ice east of the elevator is being removed to create the Topo Gallery. A triple 1 '/,x 11 7/8 LVL beam will be installed to support the east end of these rafters where the bearing wall existed. This new beam will bear directly on top of the perpendicular triple 11 7/8 LVL beam at the south end,and will be supported by a 4-2x6 column at its north end. Please give me a c �� questions or comments on these framing items. Y Y O�'�°$ •••�(°°r,'�O Sincerel � v� �� � �o e o . LE , � , Timothy . o "•a..«�•'��G� President ssl0 N A�E� , � � � • d [ i � ! G i � I ' � . � ' o �� ��lT�� s� -8G11!.�I,NGi boY�e en9ineering,Inc. SMEEf NO. � � �� OF ' DQ 143 e.meadaw dtive suite 390 ��1r�,L�11 �f A crossroads sfapphg center CALCULA7ED BY { �-�� DATE � I � `��Qv � vaiL colaado 81657 970/4762170 CHECKED 8Y DATE ; scA� p REG/S 'I ............_�..........._l............_:......._ ._.. ..... ..... ..... .. ' i i i ••�` �`B« � ; i � : i : : � � : � : : F i � i � ` {���� . . , . +.... ....:..... .�.... ........ .._!............�............! .. ..---.........i...__....J. ..... ...._ ..... ' ' , �.........._.�.............:........ ._... ..... ...!+]. .,�.. ! OO : i ....'.._..._................� �... :� .... �..i........��a.... , ; : ' i ��tl � ;.. i ; ' 11.. ° . . ,.. 3 ,.. : : : . : . ' . . , �. � �•'��!d'11J1 � .. � ....__�.� �c I ./� : ;... j_��� • : .. ... _ ... a � �� � : ......... . ..:... ;.. ..; ..; . ..;. _. _ ._ . � .s~r _ o ., �� ; � ; � � � ....... � { �. �? .; . � ... ..� ; ; : ; : ; G;. ; . , _ ..._..._ .. f ; , : : '�"`:�.P( ._��.lr �.... . ....... r . �.. u��. ..�... �_ .. , ! ' � : : .............a_...........�..............;.............:.........._......_..................y............. �.........._:......... ..... �_.._ ... .... ..... � �...j..............1.............� . � r �._... r ...�... , : : : i � , ....... ; i �......... . � . � : i i ; � i j : ' ....i... � . _��� . .. � t;M� ; � : : . : : : : : : � ° � , : ' . . . � • ' [ . � iA . � .............}..........._;..............�..........�... .. .....__:..._........ .._. ......_........ ... .. ..... .. .. ... .... -- , .l. . i..... � . � � ... ... .. • , , ' i i i ... ' ......_'.._.........'...._... .... �.i�" ....a.•.. ....i_.. . . . . ; � . ; ....� i . i i i ; : � , ..t..: E � ....t... '... . i [ i � i c `' i . ! i � � ....._......i..............i.............i........_._L..... ' ......_A..........._`.,...........!......._..... . '............'...._......�......... ..... .... ...., _.. ........i:.. .i... .._:.... i. .... _S�J�.AI.�..._... . .... ��� : : : : : t t _..s.... .....h... . .. .... ..... a ......_.t.._._...._.. .......p........__.�V.,,`....i............A..........._. ; i i : � : ; Y i ...�.... i : : } r : : ; i ; i i i... i i ....�.... f .. ....:... ....:.. , ; . . ....�..... : .............:.............e.............'�...__...__i... ...._:......__...�..._......._�............._ _.. .... ..... ..... ..... . . . � . � i �.... _.. ..........>.... ....!.... ....i ...._ ..... ..... _ ..... _... ........1..........._e..........._i............... ..... ..... ..... ..... ..... .... ....°... • ' • � .. .._'.. � � ' � � E i i i � i I � � : 3 ....:..� i ....l.... j ..._�.... i i i i : ' i , ; . . . . � � i ; : i ....i... .. ' .«......t.... .�. i . , � : i � : : � : � . : . . �. : . . . i ' : i � '; . e � � � � � ' � � ....�.... .._�.. . .N:._...W....... r�. . . . i ,.. . . . � ._ .�..:.� . � .. _ ._ ........� ... _...._....._.....�....._.;.........._ _ _...........:..... ......_.._ ... _... ; : ; ; ;... ..i.... ��.... _ ... .... .. ..... : � ; e. ; ; . . : ,. � .. _. b : : : � , . � ...._.. ....{.... ....'... ; � � : . _.�.... ......... .......... ._.�.... ........ � : • : : : : � i.... I � f d �G . I L3 i X '��2 . � , ; ..... ..: ... ..:..............._.., . ...;.._..__.......... .__......,......._.. .. ..._.�'............. �...C�......_..� . .. _... �..._..�;..._......�............_..,.... ... .... .... .... _... : . , , � , .;.... ; : _._,_.. . _....__:.__...:...... ..�......:_ _ _; . , ,... : � � . .. , . .._. . ; ; . : t . ,..... ... . .....:.... ._.... ....... ...� _ E i ': ,��: � � ���0 t'+ i �-���� . < _ ....._._.........;__.....:_..__............._...... .. ..._ ..... _. . .... .... .... ..... ..... .... _ ......i............. ; ; ; ° : ; ; ; �', ; � ':, i j ' �_t� .�... ...;... ...'... ...i.. , ! I � : � I ; ...'... . ....a....... ...... j.... . . . . i : � . : . i S �.... . . .._...._ . ...1..:................ . _:.... ........ ,.._._...... ..............�.. � ; ; � : ! , � , , . __.,.... ........... ......._...... , ; � ; ; ; ; ,._........... e............:.............a..._..._... ....__�._....................................,..........._�......... _ ..._ � � . .... ..... � ..... ... ... ' ' ' i ; ' i -.._ ..... _ ....(..............`................ f ...... 1 . : � .:.�... i i ....r... . : i ' i i � i i � : . . . i ' . ��� � � ` ' ... ' ....i.... .._'._. ' ....i.... ........................_t....._....._:........._...... ........_....�.............�............�.... �.. . .. _`.. ; � .� i f i f ...i.... ' ...'.... ' ...... f.. . : ; � � , . f : { i . � ._.. . ....a...........d.._...... ... ..... ..... .... 1............_;............... .... ..... ... . . . r . : . ...;_._........¢.............:.... ....}............. : : : . . . , . . . j : € i ; i _.i... ; . 1 ( ? � ;.... � ' . . . t : , ` ....+.... ....`.... _:.�.... . ....�..... � . ....i... ; ; . ; : i .._j ........ .... . .. .._ � ....;... i � i ` ; i : i I i ; � � � i i I ......_:... � . : � ........._......... ..........�.........._.�... .. ...:..__.......:.............r.........._................._..._.i..................._._p._..........#...._.. ..... ..... ..... .... � _ '.._. . .........i...........!.. j � i : i j t : �. . .... ..... .... .... ..... i i I � l : : .._'.. ... ..�.`'..i : : � .. ...i... ...�....... i : : . : � . . .... ._k... ...`.. ; : •. 1 : ' ' ' ,.�.'.. ..,.. ' .............:.............e.............�..............♦ . . . C.. ... ... _ .. .... .... .'} _'... i i F ' ( i ` : . . .w '! .. .. ... . . � ' : i . � ' 'l i i i ; 't i 'i ....;.. ' � ' .... I. . ......�. .'.... ....':..... ....'.... ....'.... � ............'..........._�..............:............_i..........._..............:..._........�..........`•. . . ..... .... .... ..... . . . i � i . � � ' . ... ._. ..... ' : , '• � .. ` � . >.........._I ......._s.... ....j.... ..._,... . N1;.�Ei ' � � •` ! : � : � : : ; : : .•..:r...:. ....�....._......�.............:......._1.i..............;........_...11 .....�.........._,.............. ; , , , , : i � I . . � . .._j... � : . ....;.... . � q h�hl 8Xl� ' :�'� i ; : : . ....k.... .,��._ ;2'� ` . � L►d�G ; �.:..�.... .. :.....a 1� �` C�. , ° i.. ....{. ._.. . .. ............:......... . ....................._...............,....__.....i..........................,.........._..:.._ ..................r� _ .......�........ ... _......,......._...:........__'..._._........._........}......� ._.. .. u : ; : �, � ; � � f....�.........._.�.�................_....... ; � ; ; ; � M_f.... 1 � . , : : : . .� .� P . -�i... __..... ....... _�.... . X. ... . � ; ' 6�� i � � .........._:. . ; . _,......._a.. ........_.... � _. � ..__ _ ... ' : : . ; , , ,. ...;_..... _ � .. ......:..............�.____...a. _... .__ _... �.._. �. ..... �. : . ; , ; :. : � , � : : : ; : � � _...:... , ; , ; : : _,... F._ ; � � .,.._ t... f i I . � , , .!..... .... � � �.... W �... �.. .t.._ { � yy i ._i. i ! � y�\' � h ........_...:._.._......`.............:...._..... .........�......._.._'.... i ..........'.............i.__.... ..... .. . . . � � . . � �. ; . ....i.... � -- • � •- - ...... .... ........:.............t.............�. ..... ..... ..... ..... ..... ..... � t � ' ! > ...'... t . � : � � ..� �.... ...;.. '. j ' i i i i [ � � ...p.� ....i.. ....i... ...�.. . ........e�.V....'L�!....j..�._ i ' E p i ' _ .................. ... ........ .�..................................:.... ..'..........�.............i.........._.'. ..... ..... ._.. .... . � ; i F� ..�.�. ... ' ; � � /�. . � . ; . t... ....`_ ._L_. . _... ... _... ..... _.... ....._.1..........._j.� I y� � �.. . � ..._4. .. , r` ' i ` . i ; ..i...... (. � _ _ '. ....� ._ ._i.,�_..... ..t. ; � � i i ( � ' ' . . ...i_ ....'... � �,r : ' ....�.... .... �.... . u n . �.... i I � �,^ �( . � .........:.. . . „............ . .........;............. _ ........_I...1.�'��..._`....1.�.{�r�._�.�`_......I.........._..f.............i....._......E..........._!.............;......... ..:.`.. ... .... .....i..l..p.F.S.._...._... . Sl��3� : . : . . ; t t .� �'�1� , . : . I 3 ; . 4 . . ; i ; ; ; 1 ; �/� i t ' � ........ � F E ' i � .....�.. ......._i.............�..._�t.K......!..�... � .. .. �. • ... � : • � : : , , �' �f.N.-.�� _...... ..... ... _ .. P��...�'� , � .....................�.........;.......... .._........._.....r. i ,.�.. . .. . .. ..... ... : , . . � , . . . . . : , . : ; : ; : : : � : � i : �_.. ._� � : : : e .'• ; i (r ! E E ..., i ; ���� ' : : • : I � � . ........ ....� . � ....r......... .. ....�...........s_. " ; � . ��e� '...�J� . ......... :............�........... ...:.._..._: .: .. _.....:....._ _;..._�;�� _� t.�h.....� �.C.:!..........._;..... .._ ._ _.... _ ..... ._. .... _ _... .... ... _.._. . : : ; � : : - -- ' : : , : ; : : ; ..;._. ..,. � . : ., . , ; � �.... , 1 : , : E k`���( : : : � : i i : • : � x�._ ( I i ... .._�....... .... ... ...�.... _...... ....�.... _........ ; .._....'.`k{.!!!ki...._....__.__..._.........._�.............t .... ..�. ......... ..........._i_....:. �......_ {. � . ..... ..... .. . . . , . . � , ._ ._� _.....:..............._...:.... ...�.... . ... ......�......_ ' .... ` �� ..... _ ._.....i........_...;._......_.. ; + . : � . . . . : - t : : .....�................. .....r..........._�..... ; : ; ' . �j�.�✓� i i i i «..��, , .. . ...�.... ....� ...... , . : ! i ,. ' . ...t- -� . . � . _ ' ............ ._..._..............'............. ...._..w............... � � � �, , �. i . i i : . '.... ..... ..... ..... ` ..... I ' i i I � . i � ; i . . . . • .... �. �:... ..�.... ..... .� .... ........ ....i--.. � ���� ; ? ` i ; i i �. ' i , .. .... ._�.......:....... ...• . � �-YY�I _ ` . � _ . I .... _.. ... _ ...... ,.. ..... .... . .� : . : . � ��. t. ._.r..... , {.._.... , � : _. ... i : i � � ' .3.... .3... . ' � : : S� Q�Xlo �. . : � i .......:. . .... : t : .. . .... . . ... .:.._ . , _�_...........:............;.._......... .. .......:............_'......_...._.... � ... .._ .. ..... ,.......___:_. � � ; ' , ; � ; ; t...... a ........�.......; s :.... ' '. € ; � . r ' ; r0�_ ...�._.......'•..,t.: _t. _�.. ... ... _.!....... `: � ..._��.�.,'C" ,�..... , , , :._� : � ; : : : .�Xl �,I►� : , � ; , : , : : .. .. _.... ... v � . . ....�.. ...�..... ...:.... �......._: , . : . .............._..._ r........... . ......;...._....._....... .. _. ............_:............. .. .....: . ' ' �l,� ; : � : : ; ; , ..... _ ; .._ , ._.. .. _ _ ... .. � 1 4............:........._ .. ' ' ....j....... .i.... �... -. : ; � : i � ; �; i f ..._'.... ....�... ' ..._...;.... ;.... ; ° , ; ; • . � � ;... . : . ; . , :' i . . i : � I ; , � .._..... ......... .._......._ ....�.... .�.... ....... :.... .. � .............,.........._........_..._:.............'.. .......t........._..•........... ........._.;................. .................�............. .........�............_�..... ... ... . ; . . ; � . � _ _..�...... .... . .....t.............i...._.t.. .... ..... ,....�. ..... .... ..... � : � i 1 € i { .._t... . : ' � ' . . . i , ' : ..... ..;.... ....i... . ... I .....i... .. ........�.. ' � ? ; � '.. ... .._' . : :... ._i YP �. : : : : : : . : � . . . , � . : , ; � ; i ........_�...__.__:._.. ,___... . � ... ... : .. ; . : .� � � ..I.... � . . . . . . ; : , . .�.+- , , : . , , : i • � � � , � 'i ' .. . ........_�.... .i........_� .........:...._...i. ... . ...._ . . � ..... .... ..... ._ ..._ .._. _ �� ��' X ,�'- ....4... ....'._ : i ; .. I , ; : € : . .. ; ' • t : � � f � � : f... _.'. ' . � .... i � � i i ! i ...�.... ...�.... ..;.... ' i ° � � ; : , � ; � : ; ; : s � . : ..r.... ...�... _.. ...}.... .. .. . . ; ..L .:...... � .......:.. _..� ; .........:........._�........: .____.:........_:..._�............,...........a........ • t�1_� . �1- . ... .. . � . . . . _ .. ...._ _ . ... ... ... ... ...._ . ... : . : , , � ;.... , . . . : , ; : : � i ; : ..� ....'.... '. , � ...X.� ..-r-�� .U.:. .... . : ; : ; .. .� f , : : : : : : : : : : . �. ... .... : , . . . � � . ._.: . . �.. �u .��� ._._i... � : �.. _ ....�� . ; � ,_... _._ . ..:. _ ._ ._�...._._�.. , ,� .:. � . ,... .., . � .. , , : . fc� . . _� �-�� �..i.. � �. _._r. . _: , ; : � �'o � �h' _ � _ .._'_.___:. . _..'.... _'__ . ... ... ... .K4'_.���... ... �1� �', OG ' � f�X�p ,....... ; : . . , , f . _...{.... ......:......... .... ..... .... � ._..._.}.............j......._ _..... .._ _... � _..j.............;............;............:.......... . : ;... ...,....� , . ! ' : : •` ; ; ! , ....�_. i ' I I ....`.... ....i._. .�.. , j ' : I . : . . . . k ; i ...... ; , : N : � r E � . : .t.. ,� , �. E � � ..............:. : : : � : . : � . __._ ..... .... _... . .... __..... ��,�_� �...�..........._}'_...........�..._......_�._..........�.......... x._.._.._..i........_._�._.... .i i...... .t4..._'.............� __ .. ..:.... .._�_ , , ._;..... ....�._ �...<.... ....,..._ ...... ....�.... ...: .......�....__....:......... : ... _. � : : 3 ' � q 1 i � �........ _ f i ��,........p... { 3.... I .�_. I � t m� ; 5 � _.,.... ; ; , � ; i 1 d? � x ; . : ; � : . : � : : : J� .. _.. ; _ ; : , , . .. _. . �. ....._.... _�............._.. : ...._, _...�.... .. ._...._.__._...�... . � _._ . � ..._ � _... � � .. .. _ . ; ; : : , . . .... .....- - -..... __ .... .. . � � r._.. }. ....q.... ....f..... ....r... ....f.... "!� : : : � � ; : � ....4... ; � : � /�D�,? ;5�V�il�..; � �1� - � ; : , ; � , I.. ..1.... � � � , ..... ........ . .... ..�. _.... ....�_ _..{....... _�... ....�.�. ....:........ . ; _ _ __;_ � ._ � : _ ._._......... . � ... :.._...��_�...__�.�,..__..�.......�.��. .��.� .. ' ...�._....�........_' ��,I_. � ... . : : i i : � " , . p........ ._..� P... L " � i � : � ; : : � � i i ' . ; .f.... i . i i . ��. : : : , . � � . � � t�-�✓�L ; c� 3 t� ..i. ..��� .i.... , ._�.......�........F_...._;. ..._..........._�"'._.... � �'._�''.�,°�"�.._.�_ .._��... ...�l��_.._. :.l_` , , , _ .. .... _.. _... ... .... .... ... ..... _.. , : ,� �....,.. �,;.I, ; : . , , : : ..�� , ; � : � : , . .__ ...;. � : ; , . . ; : ; : �"�ax � : � �r��. � � �� � �i� �ou����_.:��%r.�.., ..:.f... , _ ..: ....�.... � , . �..:... .o� � ��.,,��,�.,,�, _ ; ' � ' i � O �/ � � �� ���.�� BUILDERS CORPORATION May 19, �008 Town of Vail 75 S. Frontage Road Vail, Co. 81657 Re: Bridge Street Project � To Whom It May Concern: This is to advise the Town of Vail, that Highland Builders will not use any of A&D building property for any staging area until an agreement has been signed by both parties. However, we will use the existing easement located on the east side of the A&D bui�ding to access the Bridge Street property. Sincerely, Mark Hallenbeck � C� C� C OM � MAY 19 1008 2598 Palmer Park Blvd Colorado Springs, co ao9o9 TOWN OF VAIL i h $ ���A1�TI� BUILDERS CORPORATION 4/28/08 D�parhnent of Community Dieve%pment Bui/ding Safety and Inspe�cbbn Servic�s 75.Soutt�Froniage Raad � - �ai/, Co%rado 81657 0 970-479 2138 v FAX 970-479 2452 � � � � RE: Bridge Street/ Rucksack Building. � � � C3 � To whom it my concern, � bA � � Highland Builders Corporation will employ the following for all special inspections: 1. CTL Thompson inc. of Glenwood Springs. 970 945-2809 A. Soil preparation. B. Steel Construction. 2. Boyle Engineering inc. of Vail, Co. 970 476-2170 A. Helical piers inspection. B. Masonry. 3. A&D Asbestos Testing and Consulting: No Asbestos in the building. If you have any questions, please give me a call at 719 499-9248. � � � �:� �n �� n Mark Halienbeck D Highland Builders Corp. � -ro�vN oF vai�. 2598 Palmer Park Blvd Colorado Springs, CO 80909 , -- -- �_ ,�,. � � . . a '�-.------�.--,' . �' '? `� Ci t� G `���' ,��' DISTRICT COURT . � .. F.api�Cpunty. C;uerada �:Ll�Y4.— ��� C9riffiedtq be fu4t, sr� and corr�Gt ._ , ; b,�K... 1�� 2�! y�s �� , � copy ol;itt@ ori ii�a�}n my custady. rR3:F �_ � . ._ . .._... __. � . �.�:�.' ..._......_,_ ._ �,. � e�_._._-- —, � � . � ' . _ �..�J DISTRYCT COURT, EAGLE CQUNTX� COLORADO �J� � C�,���� Case No. 86 CV 76 �r �'/�' / e+�� / Q�?-�.�?=�� � "G'�2_ ;� ,.., � -- ��,i�r� S�TTLEIYtENT 3TxPULATZON AND ORDER - � �j .�n �� LJ �/ OTTO STORK, , .-._, - �-� ( Piainti!!, v. TOWN OF VAIL RICHARD T. SANTULLI� GEORGE T. PRUSSIN, IYIYD AML�RICAN M�RTGAGE COMPANY, B1i1NK AMERYCA BUSINESS CREDIT CORPORATION, A 6 D ENTERPRISES, INC. , FIRST INTERSTATE BANK OF GOLDEN, BRIDGE STREET REAL ESTATE AND INVESTMENT COMPANY, LOWER BRIDGE STREET TRASH ASSOCIATION, TNC. , PUBLIC TRUSTEE �F EAGLE COUNTY, J�1LL UNKNOWN PERSONS WHO CIJ1Ili ANY INTEREST IN THE SUHJECT MATTER OF THE ACTION and DOUG NELSON, Defendants. PlaintiPf Otto Stork ( "Stork") , delendants George T. Prusein and Richard T. Santulli ("Prussin and Santulli") and delendant Chra►sler First Bu�insas Credi� Corporation fka BancAmerica suainess Credit Corporation ( "Chry�lar") � stipulate and agres ae followa: tt' � B � � I T � L � ` .. — Sy aqreement dated Auqugt 2, 1967, and rocorded August i0, 1967, in Book 211 at Page 26 0! ths raal property records � of Eagle County , Colorado ( the "Agreement" ) A & D Enterprises, Inc. , Fit2hugh Scott, Jr. and Ottie Kuehn aka Otto L. Kuehn entered into An aqreement relating to the use an� occupancy oP contiguous parcels of real prop�rty which th�y then individually owned. A b D Enterprisee, Inc. was thsn the owner of the real property described in the Aqreemen� ae Parcei A; Fitzhuqh Scott, Jr. wae then the owner of the real property described in the Agreement as Parcel B; and Ottie Kuehn aka Otto L. Kuehn wa� then the owner of the real propsrty described in the Agreement as Parcel C, Pruasin and Santulli are now, and eince January 1985, have been, the owners, as tenants in common, of the real property deacri�+ed ir� the Agreement as Parcel A and Stork is now tt�e awner of the real property desc+-:bed in t�ne Agreemen� as Parcel B having acquired said prop�a�-ty by warranty deed recorded April 29, 1975, in Book 239 at Y�qe �s01. Defendant :. Chrysler clafms an interest in Parcel A by v�rtue of a deed of �rust xecorded January 8, 1985, in Book 404 a� Page 416 of the real property recorda of Eaq'e County� Colorauo (the "Chrysler Deed of Truat") . Amonq other things, the Agreemsnt provided dt paragraph 10 theraof: Tha owner o! Parcel A hereby grants to the ow�er of Parcel 8 � rfght-of-way nnd easement �crose tha East 17.36 feet of Parcei A for: ingress and egrass to and from Parce2 B to Gora Creek Drivo tor �ho use and benefit ot tRe owner oP Percel B, hia guests, tenants and aseigns. (the "Easement") . Atter thsy acquired PArcel J►, Prueain an� Santulli cauaed certain improvamante and renovations to bs mado to the improvenanto already situatod on Parcol A which improvemants ' had baen in place when the Agreement was executed. In the course of makinq those improvaments, Pruasin and Sar_tulii caused the east wall of the buildinq upc�n Parcel A to be extended into the area ot the Easement. Foll�winq the completion of the im�rovements by Prussin a�nd Santulli, Stork, as the owner of Parcel H, filed this actian in the Eagle County Diatrict Caurt seeking, amang other things, damages from Prussin andl Santulli and a court order requirinq � ths removal of the ia�pro�emente that encraached into the area � oP the Easeaaent. Chrys3ar was named a� a party by virtue ot � ite interest in Paresl A created by the Chryslor i�eed o! = mruat. Douq Nelson wa� named as a dafsndant by plaintilf because he ie the tenant of Stork �+nd is in possession oP Parcel B under a laase. , All other defendanCs were either dismissed by tha court for failure to answer or disc2aimed any intoraet in the property which wae the subject matter of the action. - Stork, PruBSin and Santulli and Chrysler aro de�ixoue of resolving all claims deaert�d in the actfvn and o! providing against �Cuture uncertainty with reBpect ta the Eaeement and the remainder of the Agreement and ot amendinq the Easement across Parcel A for the benefit of Pa�rcel S . in coneideration af the foregoi.nq and the mutual promiees herainafter set forth, the partiea nqree as follows: 1. Prussin and Santulli shall pay or cause to be paid to Stork the eum of $27, 500.00. Said payment shall be made - 2 - to Stork thraugh the office of hia counsel , Fredric B. Butler. 2. PAr+�qreph 10 0� the Agreament shall be and is h�reby amonded in it�e sr.tiraty to provldo ae tollowtr: The owner of Parcel A h4reby qrant� to tbe owner ct Parcel B a nonaxclunive right-of-way and et�aement tor inqroas and egrese to and lrom Parcel B to Gora Creek Drive for the uso and benelit ot tho owner of Paz�cel B, his guests, tQnants and as�iqns, which easement is described as follows: That portion of a parcel of land describad in Book 188 at Pago 151 0! tho Eegle County, Colorado, Clork snd R�cardar's records, ssid parcol lyinq within Lots a , b and c, 81ock 511, Vnil Viilage, First Filinq, accordinq to ths xu►p thersof recorded in the o!f ice o! the Bagle County , Colorado, Clerk and Racorder, describsd as lollow�t Beginning at the northeast cornor of eaid parcel of land, said point ot baginninq � also being th• northaaat cornor nL � said Lot a, thonca alonq ths Qaatarly ;. l�.ne of said parcal S0o deqresa 09'00"E � 54.3? feet to the aoutheagt cornsr o! ~ said p�rcel; thence along the aoutherly line of oaid parcel S89 deqress 35'22"W 17 . 51 teet ; thonce departinq •aid southerly lino 5 courses 1) No0 dagr�ea 09' 00"W 4.50 feat 2) N69 degre�a 51'00"E 4 . 50 faet 3) N00 degrees 09•00"W 18.00 teet 4) N44 degreea 51'00"E 7.08 lett 5) N00 degreeB 09 '00"W 28 . 24 feet to the northeriy line oP said parcel; thence along said northerly line 8. 10 feet alonq the arc of a� curve to th4 riqht having a radius of 285.89 feet, a centrai angie of Ol degrees 37 '28" and a chord that bears S80 degrees 55 ' 39NE 8. 10 feet to the point of beginninq, corttaining 0. 0134 acres more or less . ( the "Aasndsd Easement�} . A copy of a survey dated April 13, 1988, showinq the Amended Easement is attnched hereto as Exhibft A and incorporated herein. Stork hereby quit claims �o Prussin and - 3 - . . � i i Santulli any portian of the Easement not within the area of the Amandsd Easement. Except as harein amended, Prussin and Santulii anc� Stork ratify, approve and conPirm the ownership QP the orher in the real prc��erty, imprcvements, easements and tice attendr�nt burdena and benefits deBCribed in the Agresment. 3 . During the construction o! �mpr.ovements on Parcel A by Prussin a►nd Santulli, a gas metQr Qervinq Parcel B was removed or diacartnected so that th� gas eervics to Parcel B has bean interrupted. Prussin and Santulli chall not object to Stork reattaching n qas �eter ao his solo exponse tv the linQ Rarvinq Parcel H so lo�q as Stork abtains apprcpriata approval lrom qovernmental authoritias and does not damaqe Parcel A or the area of the Ayaended EASement. Stork will undsrtAke to locate such matez in a manner that has thQ l�ast significant aesthatic impnct. 4. Stork, upon paynent to his ot the swe described in paraqrapA 1, co�apletely and uncond�.tiona.11y r�loa4ea, waivos, lorQgoa and diacharges any and all known or ur►known clalms wh�ch he a►ay havo nqainst Prus�in and 3antulli, th�ir haira, •xocutora, administratorw, attornsys und agonta o! and gram a►11 , causes ot nctian, suite, suse ot atonoy, accounts, � bills, covennnts, contracts, controveraies, agreoments, � promises, treapasses, damages, judgments, executiana, claims :� and damands whatsoever, in law or in equity which he �ay have ` ever had, now has or which his assiqnee4, emp�oyees, hereatter can, shall or �►ay have, lor, upon or by reseon of, any mntter which wds the subject of state court action, District Court, Eaqla County, Colorado Cnse No. 86 CV �b relating to tho property known a� Parcal 11 or tho A � D Building, or relatinq to the eaea�aent creatsd in the Aqreement �nd any trespass or damaqe relating to the improvements to the A & D euildinq psrformed by Prussin and Santulli as such etfect Parcel B. This reloase is not intended to and does not release futur� performance af obligationa aet lorth in the Agraement or the Amended Easement. 5. Pru��in and San�ulli completely and unconditionally re�ease, waive, forego and diseharge any and a12 known or unknown clmims which they may have e►gaf�nat Otto Stork, his � heire, executare, administrators, attorney�r or aqsnts ot and lrom a12 causea ot a►ction, auitg, oums o! noney, A�counts, covenantg, contracts, cantroversies, agreements, promises, trespaeses , damagea , �udyments, clains and demands whatsoever, in law or in equity whieh the� max ever have had, now hava or whiGh they their aesigneas, employees, offiasrs and directors k�ereafter c�►n, shall or may �ave, for, upon or - 4 - by reason of the clairas asaerted by them aqainst Otto Stork in state court action, Distrsct Court, Eagla Count�, Colorado Case No. 86 CV �6 relating to the liling o! s�id action againet them. This release is not intended to and does not releaee futura pe�rlorn�Ance of obliqations set farth in the Aqraement or the AraenBed Easement. 6. Chrysler hereby consents to the a�mendmenL of the eas�ment deecribed in the Agreement to that provided in tbis Settlement Stipul�tion and ratities aald J►mendsd Easement. 7. The partiea hAVa authorized and directsd their cauttsel to file thi� Stipulation with th• court to be �pproved and entered as the order o! the court. �t is further agreed that the court may snter an order dismiasing this action vith prejudice and that tho Lis Pandens rQCarded by plaintilf ba dismiesed as providad in C.R.C.P. 105. 8. Ea�ch pnrty agreas to execute auch additional documente as nay bo reasonably necas�Ary or convenia�nt to etfsctuats the terma of this Stipulation. Should any party Pail to oxacute suah documant upon roquQet, tha C2erk of th�e Eaqla County District Court is authorizod upon ex parte npplication to exeaute such necesga►ry or conveni�nt documen� for the lailinq or refusing party. Stork and Prussin and Santulli shall be reaponeib2o tc p�y thair own coa�s and fees incurred in this Action. FREDRIC B. HUTLER, �4722 � Counsel for Plaintitt � P.O. Box 960 � Eaqle, Colorado 8163a ;� (303) 328-7178 � WE EL �. PORTE�2FIE� JR. , 81 � � � L� L ..1�'�%'�Ct �„!� �'`%F�%� Attorney !or Prusain d Santu li ZU05 East 20th 1lvenue Denv�r, Colorado 80205-5601 (303) 393-0933 ROHINSON & MAI.LON EDWARD C. SELLS, �12924 Attornays for Chrysier 1202 Nighway ?4, Su�te 311 Evergreen, Calorado 80439 (303j 674�•3351 - 5 - o�ro sTO�c GEORGE T. PRUSSIN � _ RICN�IRD T. S1WT[1LLS CHAYSLER lIRST 8U8INES8 CREDIT CORPORIITION � � eY= � _ , � v � � _ ; ! � , , ` ^ � ( � • .. b � � STATE OF COLORADO j COUNTY OF EAGx.E ) s�. The foreqoinq Settlement Stipulation wag acknowledged before mo this day of , i988, by Otto Stork. Witnses my hand and ofticial ssal. My commission exp�res: . Notary Public � STATE OF NEW YORK ) COUNTY OF ) �ae Th• tcregoinq Settlament 8tipulation waa ecknowlodqed bRtora ma this day ot , 1988, by Gaorqe T. Pruesin. Witn�ss my han� and o!licial seal. My commiesion expires: _ G� � � Notary Public .,. .., .. STATE �F NEW YORK j COUNTY OF ) ss. The loregoing Settlement Stipulation was acknowledged before me this day of , 1988, by � Richard T. Santulli.. Witnese my h�nd and cfPic�al. seal. I , My commiasion expires: i � � Notary Publia � I � . - 7 - � � STATE OF COIARADO ) COUNTY OF ) s8. Tha toregoing settle�ent Stipulat�on was acknow2edqed bator4 me thie day o! ., 1988, by a� of Chryslsr First Businesa Cradit Corporation. Witness my hand and oPticial seal. My commission sxpires: . Natary Public _ �BPE$ The Poreqoing Settlement Stipulation is approvad t+nd ontered as the order of tho court thio da�y at , 1988. � BY THE COIIRT: � : � ,. .., ` � DISTRICT JUDGE - 8 - by reason of ths claims aeserted by them aqainst Otto stark in etate court a�tinn, Di�trict Court, Eagle County, Colorado Caaa No. 86 CV 76 relat�nq to the tilinq o! said action � against them. This release ia not intended to and doea not rslaasa future portarmanaa of abliqetioria �at rorth in the Agreamont or the Jlmended Easement. 6. Chrysler hareby consente to the amend�ent of the an44�ont describe3 in the Agreement to that provided in this Sattlem�nt stipulatian and ratitios said Amandad Easament. 7. The partios hava Authoriz�d and dirocted thair counael to tile thi� Stipulation with tho court to be approvad end entiored ee tho ordor ot tAa court. It ie turth�r Aqrood tha� the cnurt nAy ontor an ordsr diamis�ing thi� action with preiud�co nnd that th• Lis Pandons rocordod by plaintit! be dis�isaed as prov�dsd in C.R.C.P. 105. 8. Each party agrees to axecute such additional docunent� as may be rea�onably noco�sary or convaniant to sffo�tuato the terms of thie Stipulation. Should Any party fail to •xacuto auch document upon roquoat, tha Clork ot tha Eag2e Caunty D3strict Court ia authoriz�d upon ex parte application to axocuta �uch noceeaary or aonv.ni�nt docuaont !or the lallinq or rafusing party. Stork a�nd Pruaain and Santulli sha12 bo reaponsible to pey thair own co�sts and taes incurred in this action. FRE�RIC B. BUTLER, �4722 o �" Gi. � �- � Courteel !or Pl a nt i f t '- P.O. Box 960 .- : Eagle, Colorado 81631 � `" (303j 328-7178 I WENDELL B. POR�'ERFiELD, JR. , �5881 Attorney Por Prusain and S�ntulli 2005 Eaet 2oth Avenue Denver, Coloradc 80205-5601 (303) 393-0973 ROBINSON & MALLON EDWARD C. SEI.E�, #�1242a I � Attorneye for Chryeler 2202 Highway 74, Suite 31I ' Everqreen, CoZorado 8U439 (303) bi4-3351 — 5 — . i � � � � by reason ot the claims asaerted by the� ayainst otto Stork in Btate court dction, Dietrict Court, Eaql� County, Colerado Cnae No. 86 CV 76 r�lating to tha lilinq o� said action againat thom. Thie release is not intendad to and does not rsloa�n Puturo p�rtor�ance af obliqationo ��� Yortn �n �he Agraam�nt or the 1►�a�endad Easement. 6. Chryalar hereby ccnsenta to th� a�ondmont of t�4 �aa�m�nt d�scrlbod in ths Agreomont to �hak providod in thi� Sottleaant stipulation and ratifioa said Am�nd�d Easom�nt. 7. TAe partiee have authorizod and directed their _ couaoel ta tfle thi� Stipu�ation with th• caurt to be approvad and entered da Lhs ordar o! ths court. It i�s lurthar aqreed �hat the court mAy enLer an order dismissir�g thi� action with prejudice and that tt � Lis Pwnden� racordad by plainti!! be df�aisr�d e►• provid�d in C.R.C.P. 145. 8. Each party aqrees to oxocuta ouch additional docum�nt• as may b• roaaon�b�y nocA�UATY or aonveni�nt to � •!loctunta tha t�t�as o! thir Stipulation. Should any party fai], to sxocuto Quch document upon raqusst, th� Cl�rk o! th� Eaglo County District Court ie authorizod upon •x pnrte �+pplicatian to sxecute euch necsesary or conveni�nt do�wa�nt tor tho lniling or re�sstnq perty. Stork and Prussia and I5antulli ehall ba regponsible to pay their ot�m cost• and toes incurrod in this action. � FREDRZC 8. BLITLER, �47Z2 ,� :� � � : Counael !or P1AJ.nttlt ! P.O. Box 9b0 � Eegle, Colorndo 81631 � (30�) 328-�1�8 WENDELL 8. PORTERFIEL�, JR. , �588I Attorney !or Prussin and S�r��u►1�1 ZoO� East 20th llvenuo Denver, Coloradp 80205-560� (303) 393-0933 ROBINSON i MALI.ON � �DWARD C,� SELiS� N� 92 ,r : / . �f �' �� F � ''.` 1. , ,. . �...,_.� � A�tarn y� for Chrysler � 1202 Highway 74 ! Sut�te 3].1 Evergreen, Colarada 8C14�9 , (303) 674�3351 � _ g _ � � i . o�ro sTORx G RCE . PRUSSIH RI D T. 8�1NTtTLL� .( �/S!c n-�C . CHRYSLER FZRST BUSINESS CREDIT COEtFORAT20N ey: � tr'; � :; . � _ - 6 - . i ! STATE OF COLORAAO ) COUNTY OF EAGLE ) es. The toregoing Settlemsnt Stipularion was acknowledged be�are mo this day o! , 1968, by Ottc Stork. Witness my hand and official seal. My coatmie�sion expires: . Notary Public STATE OF NE YORK ) COUNTY OF } sa. The foregoin Settlement 5tipu ation wa4 nckr:owledqed I b�toro ma thia � day ot , 1988, by Gsarq� T. Pru�sin. Witnesst my hand and otticial al. My commiseion expirea: . � .. h'EVIN D�LO;�i � �Y P��c.����e u�rlew Y�rk `�` � No.a1-as�es27•� ;;, ��el+r�do�n a,bw►rr ca,nN �,) N Publ ic � COf�M�sio�r�Cxpires,lerwary 31,16OSL. � STATE OF N YORK ) ;;OUNTY GF � ) ss. The foregoin Settle�aent Stipu tion waa acknowledqed before me this � day ot , 1988, by Richard T. Santu i. WiCness �y hand and official ae a. Hy commiseion expirea: � � � N KE1AN DIlLO ; ��yPuab.S�ats a Nrw`fb�k ° Na a��+e�ss�z N ai'y Publ c , ��Nu�ary�31�190,� � � � _ � _ 3 , , � i • OTTO STORK ' GEORGE T. PROSSIN RICH�IRD T. 311NTLiLLI CHRYSI.E1t FYAST BUSINES$ CREDIT CORPOR�ITYON eYt . ; a : v: _ ,_ _ _ .. _ ` .,. ` . - 6 - , STATE OF COLORADO } COUNTY OF EAGI.E ) 8�. The forego g Ssttlemen Stipulation was acknowledq�d bafore mo this dAy of , 1988, by Otto Stork. Witness my hand and otficial aeal. My co�amiasian expirea: ��(1����� . . . � �l - � . � . " Notary Public � STATE OF NEW YORK ) COUNTY OF ) �s. Tb• toregoinq settl�ment 3tipulatian was RcknoWlodqed b�toro m4 thir dAy o! , 1988, by G�orq� T. Pru�►sin. Witn��s ny hand and o!licial o�al. u� My conmission oxpirsa: . i�3 � � y� Notary Public STATE OF NEW YORK ) COUNTY OF ? ss. The foreqoing Settlement Stipulation was acknowledqed before me this day of , 1988, by Rfaherd �'. 8antulli. Witneae �ay h�nd and otficia� seal. My commiasion expires: . Notary Public - 7 - OTTO STORK GEORGE T. PRUSSZN RICHARO T. 81lNTULLI CNAYST.ER FIRST BUSINES3 CREDZT . CORI�(� N � r 8Y: _ t�D �t. , :., � . � ..r .. 6 _ . . . : STATE OF COLORAD4 ) COtINTY OF ) 4s. Th• lorogoin$ 8ottlomont stipulation was acknowlodged b�tox� m� thi• '� day o! �,.�'1w� , 19fl6, by �A�.�. �'. �1y1hQ�.ti.t'�,,L__ a� � v;�s f'�.a� ��.t ot Chryolor Fir�t 8u�in��a Cr�dit �orporation. Witnos� my hand ard otlicial asal. �. ' `. . My cammission expires: .=1- �� -`/.�_- . • -_ ' ' , a��� r � !],�`�-i .� . NOtatt! PL1bl�C � '"' 4$QEB Ths torsgoing Settlement Stipulat on is approvod und ont�rqd a� tha ordor o! the �ourt thia � �dsy o! �,,,�,M'�� , 19 6 8. BY THE COURT: : !NI WNI. L JONE�J DISTRZCT JUDGE i� U: � _ � - 8 - .� � • 'tlint portiun of � parcal. oE lnnd dencrlbed 1n Bouk 188 et Pwtte 151 vf [he Kn�lu Com�ty, Colocrdo, 41urk and Rucurd�r'� [�curd�� �rld peccul lying viihlu Lots r,D end c, Block SA. Vu11 Ylltriga. F1ret Fill»g, uccurding to U��s •up t1�eTuof rururJeJ iu ehu uffJcc uf the wagle Cuunty, Culorxdc�. Clark ..uJ Itucucd�c� deucribad au fullowa; Brgliuiing at the nurti�euat caroer uf suid parcel of lund, uatd polnt of bngi�uiing elao 6etng thr no►'chra�t curnec of satd I.ot a, thr.nce elung che euyt�rly line of aald parcrl SOU°U9'OU"L� 54.:11 fea•c tu the aputhuxat curucr uf dald parc�l; theucc ulu�►g �hc nuutl��+rly ll��� of eeW purci�l SA9')S'?2"W 17.51 fent; thcnre d��p.+r�Jug nald soutl�4rly 11��C S cuuryca 1) NW'09'OU"M 4.50 fee[ Z) N89'SL'UU"L� 4.50 fcet �) NW°09'AU"Y 1B.W feet 4) Nti4'S1'QU"ii 7.08 f�at 5) NW'U9'UU"N 7H.24 f��t to thn nuttl�a�rly lip• of u�►fd peecal; . 1I1411Cb ulung ruid norab�rly linr R.lU laet wlung tl�M �rc of a curve to t.he � rlbht buving a rnJlon of 'lHS.89 fceC. n cunu'xl auKle uf O1']7'28" +u�d a .rl�ord Il,:it b�nra tiH0°9�'3�J"M: M.IU f.��t t�, thc pulni uf beglunl��.�;��t.�lntng U.UI ll� .���'oti t�un't� ur Ir�s. �Rsri/f Dece__� /s ��__._. _ ��f_.�`+�. ��� � ,._,.._•'�'��� �.l'iLlll� .�.�GC�111Ct f � s 1 CulOtelO P.1..S. 'l� :� 't3.'OS fa � � �._ • �f�/p�'�I ���0��� G 0 R E C R E E K 0 R I V E t 40' 1 ••���•�+•�•'" N=295.89� �=50.07' R=zs�e9' (�} �s ON�7•=t• v_: �,•w• :� cN.s w�ss'ss"c — a�o' " ( vo s. ""�� � �� / e ��/�, w �:T � o 0 ��; o 8 :% o PARCEL OF LAND �g�',. ,- � (BOOK 186, PAGE l9� 1 �$,� �� --"_.____._�.___ —._.�._ �' ��� . C NN°S1'oo°e )j`,/;! TRACT G ZOfI� / .' �'�-� 1/EME�t LCT b I������,/ I m PAVE NEQ.=/ 'pOCK WAII I -� aPE}' ' � OUTI�NE OF TME AB� ` � � ��/ dWIUiNG 4� - . , �'� A ,� i M> � %,/ � / a ��7 ,/ . � . : � Ni+9°��bO��E ° � • � ��O� � o �._�.-� r _--_ ____»�_M.�._.. ._._._ � t , � NOO��OQO.,w /' � � '/�/�,`�' ,�r�T ��� �CT : � Lr �f ' --- r �� � * S89°35�22�W � N69°56�58"W % 1751� soo°o�'O2"w � 214� ; PaRr oF �or C iiNDING I` Bun.OirvG OuTUnE��� STA�R E i �g � _,r.rd.�. '�' : . _. . ' .. .�. , ` ' � �:. � �..... . .�,.� � .�� .. . _..�.. '.: ! TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT COMM BUILD PERMT Permit # B07-0360 Project# PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.......: RUCK SACK BUILDING DRYWALL INSTALLATION Applied .. . : 12/11/2007 Parcel No....: 210108244003 Issued . . . : O1/18/2008 Expires.....: 07/16/2008 OWNER ROSENQUIST, RICHARD N. - BROW12/11/2007 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT HIGHLAND BUILDERS CORPORATI012/11/2007 Phone: (719) 499-9248 2598 Palmer Park Blvd. Colorado Springs CO 80909 License: 208-A CONTRACTOR HIGHLAND BUILDERS CORPORATI012/11/2007 Phone : (719) 499-9248 2598 Palmer Park Blvd. Colorado Springs CO 80909 License: 208-A Desciption: INSTALLATION OF DRYWALL ONLY ON EXISTING WALLS AND CEILINGS Occupancy: R2/B/M/A Type Construction: VA Valuation: $10,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 •rss+sssr+asss****a*s�s***�*t»xrr»+*s*s*�***af****r**ts*t�*r*s*sxs�+ FEE S UMMARY **vr*sx*�****s*******s********+**sra*s*****+�s*as****�*s*s** Building------> $181.25 Restuarant Plan Review--> $0.00 Total Calculated Fees--> $3 03.06 Plan Check---> $11�.81 Recreation Fee--------------> $0.0 0 Additional Fees----------> $o.0 0 Investigation-> $o.o o TOTAL FEES-------------> $3 0 3.0 6 Total Permit Fee---------> $3 0 3.0 6 W i I I Cal I-----> $4.o o Payments-------------------> $3 0 3.0 6 BALANCE DUE---------> $o.o 0 ***s****s**►*rt�*rts►rt*+t**�****a*****r*.s�r»*rs*ssss************a*******#s***s.s**�**+******+*+s***xst*sr*a*s*+****r*****s******+**#ss**ssrsax«*« Approvals: Item: 05100 BUILDING DEPARTMENT 12/12/2007 cgunion Action: AP Item: 05400 PLANNING DEPARTMENT 12/11/2007 JS Action: AP INTERIOR DRYWALL REPAIR AND REPLACEMENT ONLY .........::...,::.,�.......+...**���......:,.,.......*...*.�..�...:*.��*........�....*...�s....*,+..:+.:,*...«+..+.::...*«�.......*..�.:.:.*......* See the Conditions section of this Document for any conditions that may apply to this permit. ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: B07-0360 as of 01-18-2008 Status: ISSUED ******************************************************************************************************** Permit Type: ADD/ALT COMM BUILD PERMT Applied:. 12/11/2007 Applicant: HIGHLAND BUILDERS CORPORATION Issued: O1/18/2008 (719)499-9248 To Expire: 07/16/2008 Job Address: 288 BRIDGE ST VAIL Location: RUCK SACK BUILDING DRYWALL INSTALLATION Parcel No: 210108244003 Description: INSTALLATION OF DRYWALL ONLY ON EXISTING WALLS AND CEILINGS ***********************************************Conditions:************************************************ Cond: 1 . (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: CON0009651 ALL STAGING, MATERIAL STORAGE, ETC. MUST BE APPROVED BY PUBLIC WORKS i � I E DECLARAfiIONS � � I hereby acknowledge that I have read this application, filled out in f�ull the in rm�#ion�equired, completed an accurate plot plan, and state that all the information as required is correct. I agree�o coinply wit�the nforr�ation and plot plan,to comply with all � Town ordinances and state laws, and to build this structure accdrdin to the t wns zoning and subdivision codes, design review approved, International Building and Residential Codes and other�or�inances�f tl�e Town applicable thereto. � , � � f REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS[1V,'�ADV�NCE BY TEL�PHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM• 4 PM. ' � � -�._.__. �� � � � SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER � i i i � � � i � � � � � I � � � � **+�**********+***+********************************************�**�**�********+************* TOWN OF VAIL, COLORADO Statement *********�*+***********************************�************++*�*********�****************** Statement Number: R080000071 Amount: $303 . 06 O1/18/200810:30 AM Payment Method: Check Init: JS Notation: 1155/HIGHLAND BUILDERS ----------------------------------------------------------------------------- Permit No: B07-0360 Type: ADD/ALT COMM BUILD PERMT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCK SACK BUILDING DRYWALL INSTALLATION Total Fees: $303 .06 This Payment: $303 . 06 Total ALL Pmts: $303 . 06 Balance: $0. 00 **sr**�**********************************�**********�********************************�**�*** ACCOUNT ITEM LIST: Account Code Description Current Pmts BP 00100003111100 BUILDING PERMIT FEES 181.25 PF 00100003112300 PLAN CHECK FEES 117.81 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- � M . u APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNS�Iz`'�J�� r�2� Project#: � �v / k Building Permit#: -' IQ U � t� � � 970-479-2149 {Inspections) ������,t � � _ 75 S. Frontage Rd. Vail, Colorado 81657 TOWN OF VAIL BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, etc.! CONTRACTOR INFORMATION General Contractor: Town of Vail Reg. No.: Contact Person and Phone#'s: � �t ' �2��0 ►�:�� 2 _ y�v�� r' �' - " ��4��" Email address: � �� � �' Fax#: � ��� c� Contractor Signature� �j COMPLETE VALUATIO �FOR BUILDING PERMIT Labor& Materials BUILDING: $ ; �G,��j � ELEC7FdICAL: $ OTHER: $ PLUMBING: $ MECF#ANICAL: $ TOTAL: $ For Parcel# Contact Ea le Coun Assessors Office at 970-328-8640 or visit www.ea le-count .com Parcel# - � � � �'� Job Name: . Job Address: J'� '� �v`� {(� „� J�<.F" , Legal Description Lot:C��r� Block:.�-�-dQ Filing: Subdivision: � Owners Name�--�f/� s ��_ Address: ���z�L� �� Phone:. � ��s?u'� /" Ar hitect/Designer: . Address: �1 Phone: ;� I' v°� � �✓�-�, �=("� 'G.3 Z Engineer: Address: Phone: Detailed description of work: � �r �� � � Work Class: New( ) Addition ( ) --��i�e�el-F� epair(� Demo ( ) Other( ) Work Type: Interior(,� Exterior( ) Both ( ) Does an EHU exist at this location: Yes ( ) No( ) Type of Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial(�' Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No/T e of Fire laces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/T e of Fire laces Pro osed: Ga A lianc , i�a�:o -- -: ..11�1o��/ReUet Wood Burnin NOT ALLOWED Does a Fire Alarm Exist: Yes ( No O `�'' Does a Fire Spri�i er System Exist: Yes O No O F. *FOR OFFICE USE ONLY ;; � � Date Received: �. � i Received By: 'w '� F:\cdev\FORMS\Permits\Building\building�ermit_4-17-2007.DOC Page 1 of 7 04/17/2007 u ' . , ���� . BUILDING PERMIT APPLICATION CHECKLIST COMMERCIAL TENANT FINISH/IMPROVEMENT This checklist is to be used with any tenant finish/improvement permit application. � Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed � Plan Check Fee must be paid at the time of application for projects over$100,000 valuation (see attached schedule) �T ollowing information must be shown on all 4 sets of plans: Construction plans stamped and signed by a Colorado State Licensed Architect. C�Original building construction type per IBC chapter 6 ex. II-A, V-B �' Tenant suite or tenant space number. �r�/Tenant space location identification. Show location of the tenant space within the overall building. C�' Floor plans with existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index. Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. ►�� Reflected ceiling and finish plan. Type of materials must match the fire resistance/type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index �a Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. ���� Means of egress plan. Show all occupant loads and number of exits from the tenant space � Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel, separation of exits comply with code, illuminated exit signs are shown. �964 Windows shall be labeled with size, operation, safety glass. �k All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements. Accessible maneuvering clearances provided at all doors for accessibility per ANSI 117.1 Service counter-tops and built-in work stations provided with accessible areas per ANSI 117.1 � Bathroom facilities. All accessible/adaptable features, clearances and turning spaces provided per ANSI 117.1 requirements must be shown. � Separate sex bathroom facilities provided if the number of occupants or employees exceeds (15). � Toilet room floors/walls finish schedule. ❑ Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramic tile or other approved material, extending upward onto the walls at least 5". ❑ Walls within 2 feet of the front and sides of urinals and water closets must have a smooth, hard nonabsorbent surFace to a height of 4 feet. �b� Occupancy separations for walls/ceilings befinreen tenants clearly shown on the plans with fire resistive construction details and listings specified. �' Fire-stopping. Fire-stopping e ai bing, mechanical and electrical components in all fire rated walls and ceilings. �� Plumbing, Electrical and Me ' al Plans stamped by a olorado State Licensed Engineer Mechanical HVAC plans, plumbing plans, 'cal plans/pan schedules/load calculations. � Fire/smoke Dampers on mechanical plans at all du tions into fire resistive walls and ceilings. � Fire sprinkler plans. Show all proposed work per V ' ire a ergency Services requirements ��. Fire alarm pla . Sh all proposed work per i Fire and Emerge y Services requirements have read and un rstan the requirements of s checklist. If any requir information is missing from the applic ' n, er nd e application w' ot be accepted. App' ant' Signat e e _ F:\cdev\FORMS\Permits\Building\building�ermit_4-17-2007.DOC Page 3 of 7 04/17/2007 r �� 1� �OWNOf YAII,�. BUILDING PERMIT APPLICATION CHECKLIST , ` SINGLE FAMILY/DUPLEX CHECKLIST This checklist is to be used with any single family/duplex permit (new construct� , addition, or remodel application.) ►� Town of Vail Des,ign Review Board approval must first be obtained y not apply to interior remodels) . ��,�- Plan Check Fee must be paid at the time of application for projects er $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: Architectural Plans �f� Site Plans. Provide all site plan information as requir for the Design Review Application for your project. Refer to the DRB application checklist for complete tails. ��onstruction staging plans. Provide constructio staging and materials storage site plans. I� Floor plans. Complete floor plans provided for ach level. Complete dimensions, drawing scale noted, use of each room shown on the plans. Location of m chanical equipment clearly shown : �- Building Elevations N,W,S,E elevations. S ow all proposed exterior finish materials, guardrails, windows, doors, and finish grades. � Window sizes and operation types. S cified on the floor plans or elevations. ❑ Stairways, guards, and handrails Sh all stairway details with rise/run, handrail and guard details ' ❑ Roof plan. Show all roof covering terials (Class A covering required) and underlayment, roof pitch ❑ Building cross sections. Show r f, wall, floor construction assemblies and insulation R values. Show roof and crawl space ventilation. Sho ceiling heights in rooms and crawl spaces. ❑ Rescheck compliance certifi te and inspection checklist(new construction and additions only). Provide a complete signed c pliance certificate and inspection checklist. Verify all exterior building is detailed on the building plans as re ired on the Rescheck compliance report. (www.energycodes.gov) ❑ Fireplaces. All fireplace pes shown on the floor plans. Specify gas log set, or gas appliance at each fireplace. . ' Structural Plans '' ❑ Soils Report. Inclu 2 copies of the soils report for your lot. ❑ All sheets of the ructural plans stamped and signed by a Colorado State Licensed Engineer. ❑ Design specific ions sheet. Roof live load, Deck live load, Floor live load, Wind Speed/Exposure, Soils report number and s ' bearing capacity referenced per the soils report. ❑ Foundation lan. Provide a complete foundation plan with all footing/foundation section details ❑ Framing ans. Provide complete framing plans for floors, decks, roofs. All beams, joists, rafters or trusses clearly s own. Include framing construction details and connection schedules. Other item ❑ Asbestos form completed. Asbestos test and report provided if any existing construction is proposed to be disturbed. See Town of Vail asbestos testing requirement form. ❑ Plan check fees. Plan check fees must be paid with your application. The building permit and recreation fees will be paid upon issuance of a building permit. 1 have read and understand the requirements of this checklist. If any required information is missing from the application, I understand the application will not be accepted. � ' Applicant's Signature Date F:\cdev\FORMS\Permits\Building\building�ermit_4-17-2007.DOC Page 2 of 7 04/17/2007 TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 ; 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A08-0097�ZS 01 ' � �3�I Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 10/29/2008 Parcel No...: 210108244003 Issued . . . 11/14/2008 Project No : Expires . .: OS/13/2009 OWNER ROSENQUIST,RICHARD N. - BROW 10/29/2008 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT ALARMSPECIALISTS, INC 10/29/2008 Phone: (303) 986-5900 9457 S. UNIVERSITY BLVD, #514 HIGHLANDS RANCH CO 80126 License: 693-5 CONTRACTOR ALARMSPECIALISTS, INC 10/29/2008 Phone: (303) 986-5900 9457 S. UNIVERSITY BLVD, #514 HIGHLANDS RANCH CO 80126 License: 693-5 Desciption: INSTALL NEW FIRE ALARM SYSTEM Valuation: $25,000.00 ###*#i�F##f#f#4#►#+ki�R�YRt*####t*i14###t###*�#+F###/##**######}}##►###►# FEE SUMMARY '"*�*s**s*�s:**+***�**s**s**s**s*s**rssr****t****s+*as*s**sss Electrical---------> $o.o o Total Calculated Fees--> $1,16 9.5 0 DRB Fee--------> $o.0 o Additional Fees----------> $o.o 0 Investigation----> $o.o o Total Permit Fee--------> $1,169.50 W ill Call---------> $0.0 0 Payments------------------> $1,16 9.5 0 TOTAL FEES--> $1,169.50 BALANCE DUE--------> $0.00 *##}#i#######**t##iit#►**#**►#�Rf�kR#####ii###�F#i#t#►#A###i##*ti####**►t}######*/#*######*t�l##***i##t#*tR*#*t+ki#####t�Ft*##*M*M*###t#*#�#�##►#t##i#3 Approvals: Item: 05600 FIRE DEPARTMENT � 11/13/2008 mvaughan Action: AP i#f##4##t##tt*#*rti�F4f#tt#####*��F######t###9#######4t*#�#�#M######*###t##i#########t##**#t##4#4*##t**####if#F##►t*###i�##4##t##R#t#�######�F#t+kt## CONDITIONS OF APPROVAL #i####4####**M*##�F##f#�#t##*#t##t4*####*#}i##*f#t*t#i**#f#t*#######t**t#f##�t*i##tt*M#############}#####i##1*#*#f##t#######*#*i**#�F####f►#####*## � DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved,International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM-5 PM. /�,�i� �� o�r/ �'�v/r/ SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER �**r*****«**��*��*****�******************************�:*********+�*****�**********�*******�� TOWN OF VAIL, COLORADO Statement *****�******��*****��*****r*****+*�********�**********+****************+�*******���******s** Statement Number: R080002187 Amount: $1, 169.50 il/14/200812 :26 PM Payment Method: Check Init: LC Notation: #3252/ALARM SPECIALISTS ----------------------------------------------------------------------------- Permit No: A08-0097 Type: ALARM PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $1, 169.50 This Payment: $1,169.50 Total ALL Pmts: $1,169.50 Balance: $0.00 *******��**s*�************s�*�********************�*****r**��******************�************ ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 FIRE ALARM PERMIT FEES 937.50 PF 00100003112300 PLAN CHECK FEES 232 .00 ----------------------------------------------------------------------------- I I �. �•, �- �� . � �� �� � �Y -� � y �� "�' � �U#13 _ , -� � �;� ? �. '� � _ x � � � � � �� �` �„��»�� °`�� '°- � `3"�, � �r�,e�- '""�, � :� � r`�, ��" � � �� - � °�. ` "x 'y`:.��� �fq : � 3 � ��,� .� . z �.� �� �' .�dt''v��+�w,"'�' .Ra. �.�+� �`b"�"` �''': , ry, x, . ' ' c,� '� . _ - ... . :.... ..�* , . . ^ .,*�d. - - �- . �� .� - .:ms,�,. FIRE ALARM PERMIT Commercial & Residen#ial Fire Alarm shop drawings are required at the time of application submittal and must include information listed on the 2"d page of this form. Application will not be accepted without this information. € Project/Street Address ��KS�C/r �"���;v�S ,/� 200 /,jr: L° J" G,�'/ �� ��6.5 � Project#:_ �V�� (� �'� � Contractor Information: Building Permit#:_ �jL�� '(�(� �-Z. Company:_ /7�0�!'M�/�G�a,�;s� Zn/e Alarm Permit#:_��j"�� , Company Address:���5� S (/�'��'✓e/'S%t f b�1/�f�$/y CitY: �7�-,�'��i�G�s /QahG/� State: CO p �etailed Description of Work: ; Zip:_ 6��� � ContactName:�/'�'y l.�✓���5 _-�15�����lg �I�' �}K�/'r+� S� St�r1 , Contact Ph:�D� 9�6,S9G� CeIL• E-Mail __�WP��S G2.�G!'/� eC � Q� (use additional sheet if necessary) Town of Vail Contractor Registration No.: �Qq�j — s � ^ �'�/ - - Value of Fire Alarm: $ i+7�� Contractor Signature(required) (Labor$Materials) Property Information Work Class: Parcel#: New(�ddition( ) Remodel( ),Retro-Fit( ) Repair( ) Other( ) � , Legal Description: Lot#: Blodc#: Work Type: Subdivision: Interior( ) Exterior ( ) Both(.� Building/Complex Name:��c.+G�f��..�� Type of Building: Owner Name: Single-Family O Duplex O Multi-Family O (For parcel#,contact Eagle County Assessors Office at 970.328-8640 or visit CommerCial(,�estaurdnt( ) Othe�( ) www.eaglecouty.us/patie) Does a Fire Alarm Exist? Yes O No �} � �G � �i ('�1 (� �� Date Received: E I )! Does a Sprinkler System Exist? Yes O No(;� !U� . ± OCT 2 7 2008 ! .; f � ,.W�O�'1/t� ��' VAiL TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT ; 75 S. FRONTAGE ROAD VAIL,CO 81657 970-479-213 8 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ASBESTOS Permit #: ASB07-0022 Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.......: RUCK SACK BUILDING Applied . . : 08/07/2007 Parcel No....: 210108244003 Issued . . . : 08/09/2007 Legal Description: �'Z361 -6 2 c�`i Expires . . .: 02/OS/2008 Project No . : ?? OWNER ROSENQUIST,RICHARD N. - BROW08/07/2007 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT PROFESSIONAL ENVIRONMENTAL S08/07/2007 Phone: 303-356-9598 19537 40TH STREET DENVER CO 80249 License: 767-5 CONTRACTOR PROFESSIONAL ENVIRONMENTAL S08/07/2007 Phone: 303-356-9598 19537 40TH STREET DENVER CO 80249 License: 767-5 Desciption: REMOVAL OF POPCORN CEILING FOR THE RUCK SACK REMODEL Occupancy: Type Construction: Type Occupancy: ?? Valuation: $8,750.00 Add Sq Ft: 0 Fireplace Information:Resuicted: #of Gas Appliances: 0 #of Gas Logs: 0 #of Wood Pellet: 0 a�*ss***s*s*s***sa*�*******s**s***�s+s��s*t+*s►s�►*�*�*s+�ss4�s�r*s** FEE S UMMARY ****s*t****ssfs�**s*s�*+s**+sss�*a*a*:*a**s*�*ssrs*sf+ssss�s Building---> $58.00 Total Calculated Fees--> $116.o0 Plan Check—> $5 8.o o Additional Fees-------> $o.0 0 Investigation-> $o.o o Total Pertnit Fee--------> $i 16.0 0 Payments----------------> $116.0 0 TOTALFEES----------> $116.00 BALANCEDUE---------> $0.00 **ss►***s**+s*s**f�isss****asa�a�+���:s+s*s*sas�fi*►ss*a*a*a*+s+ss+*+�s�*ss**s*►*s+s*s�+*a*►a*�*s*ss*+a*s****s�*****r*rs*ss*�*s�s++sasss*arsss*ss► Approvals: Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 08/09/2007 DRhoades Action: AP Approved as noted: 1. At least one handheld fire extinguisher must be located outside the work area (in addition to the two shown inside the work area) . 2 . Deleveries to and from the jobsite must be coordinated through Check Point Charlie and comply with all Town of Vail Loading and Delivery rules. Mike Dowling was advised of these rules. ......*�....:.....:.:�.�.....:.:.*�*�:*.:�.....�:�.*:�:..�..:+.�...*......�.*.*:..:.....*..::.�.*.:...*...:�..*:*�..�...+........:.:::..*..:.�..: See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information reyuired, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residentail Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHAI,L BE MADE FORTY-E[GHT HOURS IN ADVANCE BY TELEP E AT 970-479-2135 OR 970-479-2252 SIGNA URE OF O OR CONT CTOR FOR HIMSELF AND OWNER � PAGE 2 ******************************************************************************************************** CONDITIONS OF APPROVAL Permit#: ASB07-0022 as of 08-09-2007 Status: ISSUED ******************************************************************************************************** Permit Type: ASBESTOS Applied: 08/07/2007 Applicant: PROFESSIONAL ENVIRONMENTAL SERVICES, LLC Issued: 08/09/2007 303-356-9598 To Expire: 02/OS/2008 Job Address: 288 BRIDGE ST VAIL Location: RUCK SACK BUILDING Parcel No: 210108244003 Description: REMOVAL OF POPCORN CEILING FOR THE RUCK SACK REMODEL Conditions: Cond: 3 8 (BLDG.): THIS PERMIT IS GOOD FOR ASBESTOS ABATEMENT ONLY. AN ASBESTOS ABATEMENT CERTIFICATE SHOWING THE AREA FREE FROM ASBESTOS IS REQUIRED PRIOR TO ANY FURTHER WORK OCCURING ON THIS SITE. IF FURTHER QUESTIONS ARISE, CONTACT THE VAIL FIRE DEPARTMENT AT 479-2250. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. I ! � � I ( ( I i � i I � u ' ; ����• ASBESTOS TESTING REQUIREMENTS THE TOWN OF VAIL AND STATE OF COLORADO DEPARTMENT OF PUBLIC HEALTH REQUIRE ASBESTOS TESTING ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL WILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION FOR ALL REMODEL, ADDITION OR OTHER PROJECTS INVOLVING ANY DEMOLITION OR REMOVAL OF BUILDING MATERIALS THAT MAY CONTAIN ASBESTOS. BUILDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERIALS ARE EXEMPT. A COPY OF THE REPORT MUST BE SUBMITTED WITH YOUR BUILDING PERMIT APPLICATION • I have included the asbestos test and report with my building permit application applicant signature date OR • I certify my project will not di ore than 160 s.f. of building material. The construction plans submitted with m plication ' formation. (This will be verified during plan review, and will dela ro�ect if found to be i curate) �� � app cant signature date OR • The building was constructed after October 12, 1988. The date of construction was original construction date applicant signature date � � � I i I I � i � I II I F:kdev\FORMS\Permits\Building\building�ermit_4-17-2007.DOC Page 5 of 7 04/17/2007 � �� r _ , a 06-30-2008 Inspection Request Reporting Page 5 4:14 pm Vail, GO - Citv_Qf Requested Inspect Date: Tuesday,July 01, 2008 Inspection Area: CG Site Address: 288 BRIDGE ST VAIL RUCKSACK BUILDING DRYWALL INSTALLATION A/P/D Information Activity: 607-0360 Type: A-COMM Sub Type: ACOM Status: ISSUED Const Type: OccupancY: Use: VA Insp Area: CG Owner: ROSENQUIST,RICHARD N. - BROWN, JEFFREY Contractor: HIGHLAND BUILDERS CORPORATION Phone: (719)499-9248 Description: INSTALLATION OF DRYWALL ONLY ON EXISTING WALLS AND CEILINGS Requested Inspection(sl /� �����Q� l/ Item: 90 BLDG-Final Requested Time: 08:00 AM Requestor: HIGHLAND BUILDERS CORPORATION Phone: (719)499-9248 -or- (970) �+76-4458 Comments: JR knows ab is-to final it Assigned To: GDENCKLA � Entered By: DGOLDEN K Action: Time Exp: � I n J�,v � O� 'L/ � � i W'" n � � ' !V I � � I � Inspection Historv Item: 50 BLDG-Insulation Item: 60 BLDG-Sheetrock Nail � Item: 90 BLDG-Final i I i II i' � ' I ; REPT131 Run Id: 8082 � � *********�*�r*************************�***************************************************** TOWN OF VAIL, COLORADO Statement **********�**.*******r*******:************************�*s****+«*�**��*****��*******�****�**� Statement Number: R070001481 Amount: $116.00 08/09/200704:44 PM Payment Method: Check Init: DDG Notation: �7 Cemark Inc. �(`{�y ----------------------------------------------------------------------------- Permit No: ASB07-0022 Type: ASBESTOS ParCel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCK SACK BUILDING Total Fees: $116.00 This Payment: $116.00 Total ALL Pmts: $116.00 Balance: $0.00 ************�*****************************************************�************************s ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 58.00 PF 00100003112300 PLAN CHECK FEES 58.00 ----------------------------------------------------------------------------- I i � I I I I � i ,, APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR U �. ��� ^ Project#: (3��' `�r� ��I�,,j Building Per it#: , � �����' Asbestos Permit#: • Z� d ��OFy� TOWN OF VAIL ASBESTOS ABATEMENT PERMIT APPLICATION Required per Ordinance No. 19, Series of 1998 75 S. Frontage Rd. Permit application will not be accepted without the following: Vail, Colorado 81657 1. Copies of Generai Abatement Certificate and State of Colorado Certification 2. A copy of written arrangements with the facility operators for any temporary disabiing of the air handling systems, fire sprinkler system, and alarm systems with the names and contact phone numbers of these individuals. � / � 3. Site plan with details addressing: waste container storage location. waste load out area j J�� location. entry and exiting details of abatement area. details of entry and exiting plans for the occupants of the structure in unaffected areas. CONTRACTOR INFORMATION On Site Abatement Contractor: E����� Town of Vail Reg. No.: Contact and Phone #'s: �o�n EN v. . (3 el �'l�Oi=�n� ��o �7 S N'1;ke, t�o Uc.t �r� y7 I-S"q 21 E-Mail Address: N��/t� �W(� L�-tur {�,l• Ke.t' Contractor Signature: � • COMPLETE VALUATION FOR ASBESTOS ABATEMENT PERMIT (Labor & Materials) Asbestos Abatement: $ $�7 S v , � Contact Ea /e Coun .�4s.sessors Office at 970 328-8640 or visit www,ea le-coun .com fo�Parce/# Par'Get�# �/p j-a�Z- �f/- od Z. -" Sa�e. �'�=�C�-�-� 11�c�lk�4�.E.�t CwN st �-r� 2�57 � r-i d � STQEeT ]ob Name: Job Address: S �2�'�w o E L �jQ�l�- C.•�.o Legal Description Lot: Block: $� Filing: (�.i,�11z�� 1�I�" Subdivision: � Owners Name: �� �� Address:�� ���� �. Phone: ,,�p_�,� .-��S � Project Manager: Address: Phone: Project Designer: Address: ( Phone: � L AirMonitoringSpecialist: .�o�+� T�u Address: Qou�7°I 1„Ih«„�'r�d �Yoa"�f Phone: ��3 ySY dZ� Y Detailed description of work: ��. �.� Po ��,-� �.<<< � Start Date: q �� End Date: �� 2no� Start Time: ;�.,, ,a� Quit Time: 5,e„ P ,..� Amount of Asbestos: Linear Feet: , Square Feet: g�0 55/Gal Drums: Work Class: New( ) Addition ( ) Remodel (�j Repair( ) Demo ( ) Other( ) Work Type: Interior(�J Exterior( ) Both ( ) T of Bld .: Sin le-famil Taivo-famil M ti- ' I u Does a Fire Alarm Exist: Yes O No(� S fe - y � . No(-�-- **t�t******�**************�*�***�t�c**�**� �`r � * � * * �* �t FOR OFF �Q�.�� � � �**� � �—�� � �V�i[i�! �Y$���� �'.^�� t. �.���� ��a �'.r _- `�'��" - . /'., ',j(C"� � ;Pttbli�l�Va' �i�rtiiit�e+�`:��:�` aAci:e' °:B � _ '�• s.::: x, v.<�.; ,�_�.�,,� ;�� �, , � . � ��.� � � .Ocxv n :,�Grou ,� ,�. ��� n,� �� � � � TOWN OF VAIL � F:\cdev\FORMS\PERMIT'S\Fre\asbestos�erm_12-5-05.DOC Page 1 of 1 12/05/2005 � �-, Calorado �nvironm�n��! Sp�ci�lists bba Professional Envimanmental Se�viccs L�C Vai1970-949-9911 �,�ozporate Offiice 614 Found�rs Avenue,Eagl�, Colora+do P.�. Box 5110,Ea.gle, �oiora.dv 8�631 Phoz�e{970) 328-373Q Fax(970)328-3731 Mike l�owling: (970)�7I-5921 Ce1�1 Augusx 22,20�� � Highland Buil�� ::rs Corporation Attz�:Matk I�,� r,;t�be�k F.O.Bo�d3�4`_� Vax�, Coloradcr ���558 Re: Asbe�tos �( ;lea�ance at 2$$Bridge Str���,�ail Color�c�o Deax Mark, �'his is to con,�:� :�n that th�asbestos aba�em+�nt proj�ect�t 288 �ridge S�et, V�.il COlbr�� has been con�� �leted successfu�ly w�ith all vf, asbcstos c�vmtaining materiai removed. �� C�e��raace sazx,q I,ing was per�'ormed �y ��'oairca Inc. azxd cl�ara�ce was giv�n and report �_ is attack�ed. Sincer�ay„ �� ��. � 1V�i.ke Dowlin�,; � � d NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES . : � �oAaro�v�, � Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 �l ���� p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 1_U ��C} ELECTRICAL PERMIT Permit #: E08-0104 �� �� 2 ACOM Project #: PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status. . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 05/21/2008 Parcel No...: 210108244003 Issued . . : 05/23/2008 Expires . .: 11/19/2008 OWNER ROSENQUIST,RICHARD N.-BROW 05/21/2008 -SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT BIG BEAR ELECTRIC, INC. 05/21/2008 Phone:970-390-9221 P.O. BOX 474 LEADVILLE CO 80461 License:291-E CONTRACTOR BIG BEAR ELECTRIC, INC. 05/21/2008 Phone: 970-390-9221 P.O. BOX 474 LEADVILLE CO 80461 License:291-E Desciption: RUCKSACK REMODEL:TEMPORARY POWER Valuation: $850.00 Square feet: 0 ..*.........,,.«.,,«.,.*.,....,..,..,..,...,.....,�......*.*...,..........* FEE SUMMARY .......«««««.*....*.......,,*..*.....«.....,,�,.,�......*..«.«............... Electrical Permit Fee---------> $57.50 Total Calculated Fees--> $61.50 Investigation Fee--------------> $0.00 Additional Fees----------> $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee-------------------> $0.00 TOTAL PERMIT FEE---> $61.50 Total Calculated Fees-------> $61.50 Payments-----------------> $61.50 BALANCE DUE----------> a0.00 .»...........�..,«...«........,...,..#.*..,.................*,...*.....*....,....,.,..,.,...*...........,.,.....*.*..«........,...*,..................,.........,..«..,.*... APPROVALS Item:06000 ELECTRICAL DEPARTMENT 05/22/2008 SHAHN Action:AP SUBJECT TO FIELD INSPECTIONS Item: 05600 FIRE DEPARTMENT •r,tw*rwwwrwiw:w**,twwrwrrtrww*fwww�wwwww*wtrawa*fr*fr,trf*,r,r*a,twwwwwww*wtw,rr�,tw+rrr*r*wwww*rwwwwwwrwwsrwfnt+,t�.trwrwfwwwww�wwww�w,t,�t�wwwrt*f+*w+*wwww*w*fwww,rw�►ws.�wwwwwwwt CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ,..........«...*�..«..........�....*..*..................*....,.#..,«.......»............*,..,...,.«.,.*.......�..,....,�*..*...«*«........,..»......,....,.,.,.....,..,....., DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUEST OR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE F O 8:0 AM-4 P S^�2�— � i ure of Owner r Contractor Date I elec_prm_041908 I I I > ��********************************�***********************��*************************�****** TOWN OF VAIL, COLORADO Statement «********�***********************�************+**********��+***********�*********++********* Statement Number: R080000789 Amount: $61.50 05/23/200811:11 AM Payment Method: Check Init: SAB Notation: 6165 BIG BEAR ELECTRIC ----------------------------------------------------------------------------- Permit No: E08-0104 Type: ELECTRICAL PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $61.50 This Payment: $61.50 Total ALL Pmts: $61.50 Balance: $0.00 ***********�*��******��***********************+***********************************+********s ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 57.50 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- I I �I f � �`"► �� APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED � Project #: Q2� 0� G 2z,�1- Building Permit #: G� ���C/� Z i� Electricat Permit #: �.o� - alGy- '����''�� ' 970-479-2149 (Inspections) 75 S.Frontage Rd. Vail,Colorado 81657 TOWN OF VAIL ELECTRICAL PERMIT APPLICATION CONTRACTOR INFORMATION Electrical ntractor• Town of Vail Reg. No.: Contact Person and Phone #'s: /`7i ��� 7J o�l�' �` �r: . �s��'�,,/��'r,�,. ��r ��� S'�21 E-Ma I Address: �j Q ,, �, �, Fax#: �i j�)y . �Z,y� Contractor Signature: ,r _ . _ �:C r f, e j ti� COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials) AMOUNT OF SQ Ff IN STRUCTURE: ELECTRICAL VALUATION: $ ��j Contact Ea /e Coun Assessors O�c1e at 970-328-8640 0�visit www,ea le-coun ,com fo�Pance/# Parcel # /v /v c� �/y�.��3 ]ob Name: � � L Job Address:��� , rr �� .�c�c,c. ��,�_�c,� s - Legal Description Lot: Block: Filing: Subdivision: Owners Name: �,� � �J, �, Address: � s � S� Phone: Engineer: Address: Phone: Detailed description o�work: � �� J ,,� �^ /-_ _ �"'� �` � /C.-d'�') YGl/ C��S� (,�°�' Work Class: New( ) Addition ( ) Remodel ( ) Repair ( ) Temp Power Other( ) Work Type: Interior( ) Exterior( Both ( ) Does an EHU exist at this location: Yes ( ) No( ) Type of Bldg.: Single-family( ) Duplex( ) Multi-family( ) Commercial Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: 2 No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No Does a Fire Alarm Exist: Yes( No ( ) Does a Fire Sprinkler System Exist: Yes ( ) No( ) *�t***,�****�*��r****�**�**********�,�*��**FOR OFFICE USE ONLY**��*�r***����r*��r�r***�r�r*��r*****�*****� O�fier Feesc �; Date Received: ��' ��ry DRB Fees: Acce ted B : Planner Si n-off: � F:\cdev\FORMS\PERMIT'S\Building\electical�ermi�li-23-2005.DOC Page 1 of 2 li/23/2005 _ �. � �A11 Vt� Yt1tL�• Amendment to the 2002 N.E.C. Town of Vail Ordinance 4, Series of 2005 ❑ Overhead services are not allowed in the Town of Vail. ❑ Underground services sha//be in conduit (PVC) from the uti/ity transformer to the electric meter, main disconnect switch, and to the first electrical distribution circui` breaker panel. ❑ The main disconnect switch shall be readi/yaccessib/e,andallocated next to the meter on the exterior wall of the structure. All underground conduits are required to be inspected before back-filling the trench. ❑ In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common walls and spaces are exempt. ❑ NM Cable (Romex) can be used on/y in sing/e and mu/ti-fami/y dwel/ings net exceeding 3 sto�ies Type NM cannot be used in any bui/ding mixed with Type A,B,E,F,H,I,M&�occupancies ❑ A/uminum conductorssmaller than size #8 are not permitted with the Town of Vail. TOWN OF VAIL ELECTRICAL PERMIT GUIDELIN�S ❑ All installations of exterior hot tubs or spa's require a DRB approval from planning.This application will not be accepted without a copy of the DRB approval form attached (if applicable). ❑ If this permit is for installation of an exterior hot tub or spa on a new elevated platForm or deck over 30" above grade, you must also obtain a building permit. o If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and verify that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application. ❑ If this is a remodel in a multi-family building with a homeowners association, a letter of permission from the association is required. o If this permit is for a commercial space, two (2) sets of stamped drawings are required. E/ect�ica/ one-/ine and pane/schedu/es a�e�equired if/oad is added a�dist�ibution is a/tered. I have, ad and understand the above. � � /:' r` o t� ,� �� -� / G�' Signature Date Signed If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at 970-479-21�7. The inspector can be reached on Monday thru Friday mornings between the hours of 8am and 9am. You may also leave a voice mai� and the inspector will call you back. F:\cdev\FORMS\PERMITS\Building\electical�ermit_i1-23-2005.DOC Page 2 of 2 11/23/2005 NOTE; TH/S PERMIT MUST BE POSTED ON JOBSITE AT ALL T/MES .� �nw�o�vn�� Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0255 ?A� �o��� ACOM Project #: PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.....: RUCKSACK BUILDING,ALL UNITS Applied . . : 10/21/2008 Parcel No...: 210108244003 Issued. . . 10/21/2008 Expires . .: 04/19/2009 OWNER ROSENQUIST,RICHARD N.-BROW 10/21/2008 -SELBY,CHARLES 385 CLAYTON ST DENVER CO 8Q206-4228 APPLICANT BIG BEAR ELECTRIC, INC. 10/21/2008 Phone:970-390-9221 P. O. BOX 474 LEADVILLE CO 80461 License:291-E CONTRACTOR BIG BEAR ELECTRIC, INC. 10/21/2008 Phone:970-390-9221 P.O. BOX 474 LEADVILLE CO 80461 License:291-E Desciption: INSTALL 800 AMP SERVICE, LIGHTING, OUTLETS AND BREAKER PANELS FOR ALL UNITS Valuation: $25,000.00 Square feet: 0 i � ,.t..,....,...«..*.,««.,..««..*.......,.....*.*..,..*.,*,.*.«*.«�,..*.«««*«*« FEE SUMMARY .,......�....,.«.*«.,..*.,*..,*..*.........*..*....,,.*.....,.....�.,.....*.,..,.* � Electrical Permit Fee---------> $546.25 Total Calculated Fees--> $550.25 Investigation Fee--------------> $0.00 Additional Fees----------> $0.00 iWill Call Fee--------------------> $4.00 � Use Tax Fee-------------------> $0.00 TOTAL PERMIT FEE---> $550.25 ' i Total Calculated Fees-------> $550.25 Payments-----------------> $550.25 ; BALANCE DUE----------> $0.00 ' *.,...*«.�.....«...,**,..****..««***.,......*.....«�....�,...*.,�..,....«.,......,.««,.**..,..,.,.*.,**...****«*.*.....*.*.*...*.......,.,,................«�.,...,.*..*.*.*..,.. Ij APPROVALS i Item: 06000 ELECTRICAL DEPARTMENT 10/21/2008 JLE Action:AP .*....,*.,.,«...«.,««*.,..*...«..*............*..,..*,.*..�...****«.«*..«....«.*..,.,..,..,..,.*..,..*«***«..*.,«.*.«....*..,....*.*........,.,.........,.*,....�,.«..,,*.,.,##..,*«*«.. CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ................,,....,...**.,«*..*.«««..,.«..«................*...*.*....,....�,...,..�..*..,.......«.........**.«.*...,..,.*..*...*.*..«....*.........*..«.*,.....*,..,...,.�,. DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUEST FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE F 8:0 AM-4 PM. ���2(—�� i ure of Owner or Contractor Date �� elec_prm_041908 , i . . �****r***��************************�+***********+���**************************************** TOWN OF VAIL, COLORADO Statement ***�********�***********r*�************�**+�*************+++********r***+*************+*�*** Statement Number: R080001991 Amount: $550.25 10/21/200811:02 AM Payment Method: Check Init: JLE Notation: 6386 BIG BEAR ELECTRIC ----------------------------------------------------------------------------- Permit No: E08-0255 Type: ELECTRICAL PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING, ALL UNITS Total Fees: $550.25 This Payment: $550.25 Total ALL Pmts: $550.25 Balance: $0.00 � *****************************+***********s*****�+�********************************�********s ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 546.25 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 � � i I i I i I � i � i i � I � i i i �I � , Development Review Coordinator ' ' 75 South Frontage Road :{----�._,� Vaii CO 81657 � , ; � .F.. Phone: 970-479-2128 � �. , �� ��� ��� _ � ' � Fax: 970-479-2�172 �� � , � z a� Inspections: 970-479-2149 �������_� � � � � ,��� ,_ .: . r:; ��4 �e _ , � ELECTRICAL PERMIT APPLICATION Project Address � ����� ' � ; � Project#: a� g�►�� s� . _ . Building Permit#:�i„�— /�� , Contractor Informat�on /� ' Electrical Permit#: �� " U � Company: � ` ' ' Detailed Description of Work: j �7i�' ' ' Company Address: � ' City:� ,�� State: Zip:_��,yf� ��v�i ' Contact Name: �� � �� �'� Contact Ph: ,� CeIL������v�JcZ�/ E-Mail:�i i� 1�SP�F k� ���.wC.,/1�� cI' (Use addition heet if necessary) ! Town of ail Contractor Registrati n No: ��l f—� COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND ; ' X VALUATION OF WORK(Labor&Material) ' Cont actor Si nature (re ired) Amount of SQ Ft ..,. _ _ _ Electrical$ Property Information ; Parcel#: a/0'� G�''' �y�j�� Work Class ._ . _ _ _. „ Legal Description: Lot# Blk# ' New( ) Addition ( ) Remodel � Repair( ) Other( ) i• ' Subdivision: ' Building Type: ' Job Name: V .S !� Single-Family( ) Two-Family( ) Multi-Family( ) Commercial�) Townhome( ) Other( ) ' Owner Name: � ' ! Mailing Address Date Received: ; (For Parcel#Contact Eagle County assessors Office at 970-328-8640 or visit , I www.eaglecounty.us/patie) ' Architect( ) Designer( ) Engineer� � ^ � r, � � Name:��C.��</�(�e � D � � Phone: ��j �'=�S]-i/ ' FaX: �'�'T � 1 7�i�R E-Mail: _ __ _ __ _ TOWN �� �s�f� � "'r'J' l->- � • C� �� I� . �� . b 'S�.�=/��� � ` � �� (� � \ a V \J � 09-14-2009 Inspection Request eporting Page 12 4:32 pm V�, CO=Citv pf Requested Inspect Date: Tuesday,September 15, 2009 Inspection Area: SH Site Address: 288 BRIDGE ST VAIL RUCKSACK BUILDING,ALL UNITS A/P/D Information Activity: E08-0255 Type: B-ELEC Sub Type: ACOM Status: ISSUED Const Type: Occupancy: Use: Insp Area: SH Owner: ROSENQUIST,RICHARD N. - BROWN, JEFFREY Contractor: BIG BEAR ELECTRIC, INC. Phone: 970-390-9221 Description: INSTALL 800 AMP SERVICE, LIGHTING, OUTLETS AND BREAKER PANELS FOR ALL UNITS Requested Inspection(s) Item: 190 ELEC-Final Requested Time: 08:00 AM Requestor: BIG BEAR ELECTRIC, INC. Phone: 970-390-9221 Comments: WC 3909221 Assigned To: MDENNEY Entered By: CGUNION K Action: Time Exp: �a-s 5 ���- c�.,..�,c�.�-- �t,� o 9� Inspection History Item: 110 ELEC-Service *"Approved*" 11/07/08 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: METER FOR JOES DELI 12/09/08 Ins ector: shahn Action: PA PARTIAL APPROVAL Comment: M�ERS FOR RESIDENCE 1 &2. 01/22/09 Inspector: MDENNEY Action: AP APPROVED Comment: 150 AMP METER RELEASE FOR UNIT C2. 02/18/09 Insp ector: MDENNEY Action: AP APPROVED Comment: 200 AMP METER FOR RITZ OFFICE-RES3 Item: 120 ELEC-Rough ""Approved** 11/19/08 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: CEILING FOR RETAIL SPACES 2&3 OK PROVIDE ACCESS TO THE ABOVE CEILING J-BOXES. Item: 130 ELEC-Conduit Item: 140 ELEC-Misc. 12/18/08 Inspector: shahn Action: NO NOTIFIED Comment: NEED DISC FOR DWH BOILER NOT READY Item: 190 ELEC-Final REPT131 Run Id: 10271 TOWN OF VAIL FIRE DEPARTMENT VAIL FIIZE DEPARTMENT 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 5 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Permit #: F08-0013 ���OZ-o2 ��� Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 03/28/2008 Parcel No...: 210108244003 Issued . . . 12/10/2008 Project No : Expires . .: OWNER ROSENQUIST,RICHARD N. - BROW 03/28/2008 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT BAILEY & PETERSON 03/28/2008 Phone: 970-476-0092 108 S. FRONTAGE RD STE 208 VAIL CO 81657 License: C000002169 CONTRACTOR WESTERN STATES FIRE PROTECTI 03/28/2008 Phone: 303-792-0022 7026 SOUTH TUCSON WAY ENGLEWOOD CO 80112 License: 338-5 Desciption: RUCKSACK REMODEL Valuation: $53,700.00 a�sss*sas��*s***�r*t*sa**r**s*s+**st***a****s**�*st�**t***r****�a**s FEE S UMMARY **'"***s��*s******a*ws*ss*�*+*s*******t**a*+*s+ss*�s***+***+► Mechanical---> $0.0 o Restuarant Plan Review--> $o.0 0 Total Calculated Fees---> $2,632.25 Plan Check---> $350.00 DRB Fee-------------------> $0.oo Additional Fees-----------> $o.00 [nvestigation-> $0.o o TOTAL FEES--------------> $2,6 3 2.2 5 Total Permit Fee----------> $2,6 3 2.2 5 W ill Call----> $0.0 0 Payments-------------------> $2,6 3 2.2 5 BALANCE DUE---------> $0.00 ###t###�t#i###ti###R#####4###*##i#t####t#t#######t#*#�###}*##t##tRt#*#4R##*#*t#*#####*###*####t�**##�f#+k###*#�F#�##*#st#*4##*i##i###+F#f#t###t#t#ts Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 04/17/2008 JJR Action: DN Denied plans received 04/07/08 . Plans are not stamped. 06/02/2008 JJR Action: AP 11/18/2008 mvaughan Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ::..:�*:.�.:..:.......::***.....�....*........:.:..+........+�*...*.*..:.�.*.*..:...++#.......**.:.��.**....+..+........:..:.:::**..:...+*....... DECLARATIONS � � I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is conect. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM-5 PM. SIGNA RE O O ER OR CONTRACTOR FOR HIMSELF AND OWNER I � � *****�*�*r�**�**********��****�************************************************************* TOWN OF VAIL, COLORADO Statement ***r***+****�********************+�*�*********r**************************+***********+�+**�* Statement Number: R080002339 Amount: $127.50 12/10/200802 :31 PM Paymeht Method: Check Init: SAB Notation: 107704 WSFP ----------------------------------------------------------------------------- Permit No: F08-0013 Type: SPRINKLER PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $2,632.25 This Payment: $127.50 Total ALL Pmts: $2, 632.25 Balance: $0.00 ********r***�*�***************+**************+********************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 SPRINKLER PERMIT FEES 127.50 ----------------------------------------------------------------------------- TOWN OF VAIL FIRE DEPARTMENT VAIL FIRE DEPARTMENT . 75 S. FRONTAGE ROAD VAIL,CO 81657 970-479-2135 ���- v36 � NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES �j6�-634 a SPRINKLER PERMIT Permit #: F08-0013 ��"�1 2 Job Address: 288 BRIDGE ST VAIL Status . . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 03/28/2008 Parcel No...: 210108244003 Issued . . : 06/17/2008 Project No : ��6'� _ U Z 3�( Expires . .: OWNER ROSENQUIST,RICHARD N. - BROW 03/28/2008 - SELBY, CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT BAILEY & PETERSON 03/28/2008 Phone: 970-476-0092 108 S. FRONTAGE RD STE 208 VAIL CO 81657 License: C000002169 CONTRACTOR WESTERN STATES FIRE PROTECTI 03/28/2008 Phone: 303-792-0022 7026 SOUTH TUCSON WAY ENGLEWOOD CO 80112 License: 338-S Desciption: RUCKSACK REMODEL Valuation: $50,700.00 *asks*ss**s�ss*s*as*s****a**»sa*a**#tss*at**r*sss�*s;►*s�e�**r+****t FEE S UMMARY k►##*M#�#fii�4#it#4�##***kRR#t#*##t�k*t#t###k#*#t##i##+F#i##4t Mechanical--> $o.o o Restuarant Plan Review--> $o.o o Total Calculated Fees---> $2,504.75 Plan Check---> $350.00 DRB Fee-------------------> $0.oo Additional Fees-----------> $o.00 Investigation-> $o.oo TOTAL FEES-------------> $2,504.75 Total Permit Fee----------> $2,504.75 Will Call-----> $0.0 0 Payments------------- $2,5 0 a.�5 -----� BALANCE DUE---------> $0.00 #f###t#ttttR►##tY*t1#t#}#t*##it#t#tMi#*###4+1#####*###t#RM##*####��#}#t#4t#t#R**#M*#*####4#4#*t#►#t*#*##M�#*�#tti*t#*####t4t**i#}f#f###4f##ftt##ttt Item: 05100 BUILDING DEPARTMENT Item: 05600 FIRE DEPARTMENT 04/17/2008 JJR Action: DN Denied plans received 04/07/08 . Plans are not stamped. 06/02/2008 JJR Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG. ) : FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ##�►tt##M**#####+k##i###*##tti*####*###R#t#t**�tti*#*##}f#f##4###4####f4#*i***}f##�###i######t##t*###4#######t##*#tt#4i##►f#}##Rt#####t###**##+k#*i DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, k and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all � I Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVANCE BY TELEPHONE AT 970-479-2252 FROM 8:00 AM-5 PM. (� SI ATURE OF WNER OR CONTRACTOR FOR HIMSELF AND OWNER � � ******�***********��*****+�***********�************************+**********�******�********** TOWN OF VAIL, COLORADOCopy Reprinted on 06-17-2008 at 10:32:36 06/17/2008 Statement ****�*************�**********************r***+*******�+�*******�***r*s*+******�******�****** Statement Number: R080000362 Amount: $2, 504.75 03/31/200805: 15 PM Payment Method: Check Init: RLF Notation: #107058 WESTERN STATES FIRE ----------------------------------------------------------------------------- Permit No: F08-0013 Type: SPRINKLER PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $2,504.75 This Payment: $2,504 .75 Total ALL Pmts: $2, 504 .75 Balance: $0.00 ��***************************************************+*********�+**********+*******+*+*+��*� ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 SPRINKLER PERMIT FEES 2,154.75 PF 00100003112300 PLAN CHECK FEES 350.00 ----------------------------------------------------------------------------- ' � � I I � � � � i , j , NOTE: � THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES : �n�ro�va�, � Town of Vail, Community Development, 75 South Frontage Road,Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit #: M08-0187 ACOM Project #: PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status. . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 08/01/2008 Parcel No...: 210108244003 Issued. . : 09/19/2008 Expires . .: 03/18/2009 OWNER ROSENQUIST,RICHARD N.-BROW 08/01/2008 -SELBY,CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT SUNDANCE PLUMBING 8 HEATING 08/01/2008 Phone:970-748-8977 P.O. BOX 3684 AVON CO 81620 License: 101-P • CONTRACTOR SUNDANCE PLUMBING 8 HEATING 08/01/2008 Phone:970-748-8977 P.O. BOX 3684 AVON CO 81620 License: 101-P Desciption: RUCKSACK REMODEL: INSTALL NEW BOILER FOR HEATING AND SNOWMELT SYSTEM Valuation: $70,000.00 ....................................«...,.*......................................FEE SUMMARY......................,t......«............,....».......,..............................» Mechanical Permit Fee---> $1,400.00 Will Call-----------> $4.00 Total Calculated Fees---> $1,754.00 Plan Check-----------> $350.00 Use Tax Fee---> $0.00 Additional Fees--------> Investi ation-------------> $0.00 g $0.00 TOTAL PERMIT FEE---> a1,754.00 Total Calculated Fees--> $1,754.00 Payments---------> 51,754.00 BALANCE DUE--------> E0.00 Nftk�HfRlnitllRRfM'tk4fM*1t1��RMlRRtMFNRRR+�#RtltRlltRfhFfF4fM*fMf�M�R�l�!*4kfMfF*ri*Jie*1'*fR�tht**fRM**WMft*1r4*k#11�#*R}t4*tktk***iftRfRt�tRfM#RfRfFttfF#iF**ltF�tFlnhttR�ltAtRYN*ft�tt*#il#f�Mtl�R�tRfMR�tkt4fRY�1t*iFiF*#OflHtl�9 APPROVALS Item:05100 BUILDING DEPARTMENT 08/04/2008 cgunion Action:AP Item:05600 FIRE DEPARTMENT ...««......«..................+.....,...«.....::...........«....�..,...................�...............«...:.............................«,....«..«...::«.*...................«......,.... CONDITION OF APPROVAL Cond: 12 (BLDG.):FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond:22 (BLDG.):COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond:23 (BLDG.):BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond:25 (BLDG.):GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond:29 (BLDG.):ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond:31 (BLDG.):BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond:32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond:30 imechcanical_permit_041908 � I (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. Nt4ithMtR{eJf�fRfFltfet*ittFilR##R�hF1fFfMf��M�ltFtlfhh!►fI1O*iF*k44i*M►fR#�hMfMfF*Mf1f1rMR►f'#H�f9eIMYtfFfF*}M'#1ftR►thHt*###*k/MfF*M1'#�fRf!#**YtYMYtf**f*if�f�+�Mft##RfYRf4fFfFf4#V 4ttRifrfff+�#ROR#Mt4RR*4*NFff*i!#V RftfMfRf DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 PM. Signature of — r6or�tr r Date Print Name I � E I if I I � i � I I � I i I mechcanical_permit 041908 II i r********************��***************�***************�********�*******************�******** TOWN OF VAIL, COLORADO Statement *��**����*******r*sr:***�*��****�**********+**�++�***********r*�*�*******************�+****« Statement Number: R090000033 Amount: $47 .00 Ol/12/200902 :23 PM Payment Method: Check Init: DDG Notation: Sundance P & H 7221 ----------------------------------------------------------------------------- Permit No: M08-0187 Type: MECHANICAL PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $1, 801. 00 This Payment: $47.00 Total ALL Pmts: $1, 801.00 Balance: $0.00 *********�**********************************+++�**********r**************************��***** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 REINSPECTION FEE 47.00 C E I I � i i � ****��****************************��**++*****************�******�*************************** TOWN OF VAIL, COLORADO Statement .r********+***********��+************.***r****�**�*�**************************�*******+*++�* Statement Number: R080001690 Amount: $1,754 .00 09/19/200812:58 PM Payment Method: Check Init: SAB Notation: 2299 SUNDANCE P&H ----------------------------------------------------------------------------- Permit No: M08-0187 Type: MECHANICAL PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $1, 754 .00 This Payment: $1, 754 .00 Total ALL Pmts: $1, 754 .00 Balance: $0.00 *****��++��***************+**�***********************�*******+***********************�*�**** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ : MP 00100003111100 MECHANICAL PERMIT FEES 1,400.00 PF 00100003112300 PLAN CHECK FEES 350.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- � � , � APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED D t . TOV Project #: 'Pf�G� -����'�' Building Permit #:_�_ �+ Mechanical Permit #: G — � ,ay��#fl��r� = 970-479-2149 (Inspections) lU�ll W 1` TOWN OF VAIL MECHANICAL PERMIT APPLICATION 75 S. Frontage Rd. Permit will not be accepted without the following: Vail,Colorado 81657 Provide Mechanical Room Layout drawn to scale to include: ❑ Mechanical Room Dimensions ❑ Combustion Air Duct Size and Location ❑ Flue,Vent and Gas Line Size and Location ❑ Heat Loss Calcs. ❑ Equipment Cut/Spec Sheets CONTRACTOR INFORMATION Mechanical Contractor: Town of Vail Reg. No.: Contact Person and Phone #'s: S.>.. � `o �E.g - �tZ E-Mail Address: Fax#: Contractor Signature: COMPLETE VALUATION FOR MECHANICAL PERMIT Labor& Materials MECHANICAL: $ o po Contact�Ea /e Coun Assessors O�ce at 970-.328-8640 or visit www,ea le-coun ,com fo�Parce/# Parcel # � � ]ob Name: , Job Address: � ��. Legal Description Lot: Block: Filing: Subdivision: Owners e: � Address: Phone: ` Engineer: Address: Phone: Detailed description of work: ` t • � „�,�� �c.,���f' h - .a� g _ - Work Class: New( ) Addition ( ) Alteration (✓� Repair( ) Other( ) Boiler Location: Interior( ) Exterior( ) Other( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg: Single-family( ) Duplex( ) Multi-family( ) Commercial ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building: No. of Accommodation Units in this building: No e of Fire Iaces Existin : Gas A liances Gas Lo s Wood/Pellet Wood Burnin No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Logs( ) Wood/Pellet( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) __ i � A / � ************************FOR OFFICE USE ONLY*********** ; ************* Other Fees: Date Received: � �I�IL �,� .1 LaQB Accepted By: � TOW I L F:\cdev\FORMS\PERMITS\Building\mechanical�ermit_l 1-23-2005.DOC r.� � �8312 S�ries Sp����ications � � r.�. �, �, Model GB312/90 GB312l120 GB312/760 G6372/200 G6312/240 GB372/280 Performance Data '"� Gas Input(MBH) ,r,y: _. `, 328.3 ��,_; 440.5 . 588.3��Mii���+�'.¢' `732 6 � ,„ ���'�i��d a . .. 1,028.8 , _ Gross IBR Output(MBH) 305 409 544 676 810 944 , ,,� . ,,,, ,.. .. , _ F ,�' , �x. 220 t�' � _s���,���.��� Output at Minimum Capacity 131 131 173 217 261 306 �° � Neti�f���-' � � � �',����'� . i .�"` ��;E, . ,..��� ..��:�. ���� �� ,���"� n.�.��' � �������.. .. . Thermal Efficiency 93.1% 92.8% 92.5% 92.3% 92.0% 91.7% �, � , � � .� ; , , Cornbustion�������,�� ' �. 93.1% ;�. ��;� 92:8% ' �� . � Boiler Horse Power 9.1 12.2 16.2 20.2 24.2 28.2 Firesid��. .�, '.. . .�. ���, 0.63: ��, 0.8,9 �,°�' �' MAWP(PSI) 50 . 50 50 50 50 50 �,_ � ,£. ,;. .:, Minir�+W�� � �' fiur' f ,� , . _ „- � ;:= 3'/z ��'� �}r �j��'',� _ , ., � ��w'`.�.� a.��_ � t �, � . Maximum Gas Pressure clnch WC) 10'/z 10'/z l 0Y2 10'/z 10 10'/z Maxjmu� � ,�,:_ � h� r V !`ry��"��'"��� 200°F ^ x ~ 200°F �' , ,. _ ..��v.r;, , _ Piping Connections f u� �� t�� Flue�'i e Diameter c�U 6" 6° �.?�- ; 6° `�? g° � "< *�� # `� 8° P . . ���.�-.,��, .<. . Dimension �Yqq� 18Yz" 18Yz" 18Yz" 19'/2" 19'/s" 19Yz" �. . r . �, - Dimensi������ �'N�a��`z ":", ' 5s��� � 12�/a" F�. 4 �w.k, , .� .��r� s�e�'�s Combustion Air Pipe Diameter cA��X 4" 4" 4" 4" 4" .4' ,. ,. . , �� �..� : , , �„ � ,�� . , � Connc' ,.� �y{�-�:;T. ���;,, .. . . . .. .B i ,. .. . ����.r�S:P,`� .. . , . .. Connection cST�(B-kit) 3�4� NPT 3�4�� NPT 3/a" NPT 3�4�NPT 3/a" NPT 1"NPT r`�',M�.;4�"� d �s z�.' �':� ;� GAS,�i�nn�G,� . , ry' � Physical Dimensions s . , � . . . �� f �; �F. ,,�ei�9 #of Heat EyccharYj�r , �: �P� " Dimension cXqq� � 13Ye" 13'/e" 15Ye" 17'/a" 19Y4" 21�/a" : , :� �� �, � ., � �IRIe'IISIOtI(XpK(=7E �'� ��., T��B" `�- "t"°� i�p "��p�� , _ �_� , � �. �� , i i i� � � ?.��, � _ Dimension cA) 51 Yz° 51 Y�° 51'/a" 51'/a" 51'/n" 51'/a" � Height �`� �, . ,a.,�. � ��� 593/a" 1? ,�593/a" � ��593/a" "� � ����r���,� • Width�e; � �39'/a°� � 39Ye" 473/a" 473ie" 55!/�'� 55i��' �. .: Boiler Feet Spacing cF) - 31'/a° ; 31'/2" 393/a" �'n;. 393/a" „: 48" 48" ., Dry Weight(Ibs.) 455 455 530 585 665 730 pp �.�t� ti A` , d „ ,., . ,,v_ �.� � - ..,�:� ,� A rox.���U N��i r��� ��" a��2�, Y5",��r�^��?"��A.i+no�„.��+. .��.. �v�-k��'�u��,s� �� AA -Flue Connection GAS -Gas Connection ST -Safety Valve Connection AL -Combustion Air Pipe VK -Boiler Supply TM -Pressure/Temperature Gauge AKO -Condensate Drain RK -Boiler Return ��b 282' 8.5" XRK X� -� '--' - I - -- -- I i i d '' I 18.5'I 6. " __59_7" TM i r � � —L-RK _._i_. 55.1' —45" i ST 4Q.7" A `;, 24.2° ' i: i , � B � �� �0.6`-t' ----- �3.9` � ( �^, r• F i �. �g 1.3" FRONT VIEW SIDE VIEW REAR VIEW TOP VIEW ;,�," i � � i i a� .� ', 1� �"9 - >� �...� .,. • � "9 � Venting Guidelines This boiler requires a flue system approved for Category IV(condensing,positive pressure:to ANSI Z21.13/CSA4.9.) It can be direct vented or through roof.Combustion air can be from the space or via sealed combustion.Consult your local codes for details. Approved Stainless Steel vent systems i {d i ra r4 r :'# 1 <�� �-� q ��.., :4.,F` n � �d P}�'� x E �}� - 6 tl itl.::-' � i.�., .. �, <a �V{� ei"i����� � eit� ,1i�G . .r�� -, � i S�,i'�k�����ir s .��� ���iq� ��y^f:,� �1Y ^ � itl 'd� b d�r ,.,s @l �` Y �(�1' y �rY i . , � ����t ., , . . . � i�i�r���4^� .��j�+�'i�,�di��;Y� l�:��r��!� { ��1,� (�fr�'i��,�'�,`,, � �..�.� Heat Fab Saf-T Vent EZ Seal AL29-4C � � a , s . . �� r, � �� �R y . �.. . i� ..E /i ii q . . .��up� rr�.m ,�,���,j���,, Z-FIex �,��F���µtis����,��°���, Z-Vent IV Special Gas Vent <<, ',���;��� AL29-4C �,� , Metai Fab Corr Guard AL29-4C ! ��' il.�� . q�� °�y-. . ��e u' Y�f": �� . : p � �:�� Pro-Tech��� ,�, t�� Fas�-N-Seal� � �� , ,�,,,. .s ,�,;��. � AL29-4C ;,?; Security Chimney CI-System AL29-4C ' _ _ __ _ _ CPVC Venting Systems(Requires use of starter adapter. See Installation Manual for list of approved chimney manufacturers.) .- ,: � -,:,„. . ,,.,, , �,c + n i ,�� '�.� „ � e .;a,.�,'„,, 1 .:,' I t i�� y �� . f C. ` � �n. .�n�•� S t ��ir+,. s,h a, .,�1f,�,��. �:€ � -. a �4t.�Alu.. �P..��n„ ,.��,��`.�4'' . ', USA Spears CPVC schedule 80 pipe to ASTM D1784 Canada ' ",��' IpEX System 636 CPVC " Combustion Air Requirernents ._^ y. . t V r'�lt ��' ' �... � � .. . . . . n� � � �`�'� GB3t 2 Boiler Size a ��' ��'�� � Required Air Flow tCFM) � � �Air��Supply��Pipe Diameter�in Inches � �4� � . . . . , . . . . . . GB312/90 95 5 � ;: , }�� ,,,� � ��k�,y!! 7��,8v i�;M n Lt. .. ,l� 1�h�rt 9 +`+ � i �� � �y r.. �h g .�.�'a t . � '�,, A.:�w4� �1� GB312/120 � �'�w ''� � 95 "���,,�t� ���'-�' �� , ��� 3,��d �;.. `�' ��'y� � '��5'a+14_-4W,�°�� , �.awt�a�t)k°�a.rl�. - .'3��.�,[ .. .Ak>�.,�ry�i utr.��slir.�8��a�"�ttt. ��1�'�i��''����a G B312/160 130 6 �', ,.. GB312/200 ���` �,�,.�� ���,� . i- 160 ,+��� ,,� ��� �, �� � �' � 8 `��,�,a M ? G B312/240 190 8 � GB312/280 _ 220 .. � .. � . . 8 ._._� ti..' i' Vent and combustion air supply system installation must comply with Part 10, Venting of Equipment of the National Fuel Gas Code.ANSI Z223.1 or CSA 6.149 or other applicable local building code regulations. IMPORTANT:The flue and air supply system must be designed for a maximum pressure of 0.40 inches WC(t 00Pa)for the overall system (vent and combustion air system) Vent Terminations:Approved Tee,Termination Elbow or Roof Cap for all category IV venting systems is required. " �; � - �»t� �t�G 4s�x� i,y�,.�•� � � "3�r �°'c i.. ,��i�� .�i •:ii��,� �'• , � �' ���'���',�1�,� ��� ,�� � ` . ...,��, a . . �_� ,.,. . , e�a a. '.?, ��.�,�v;�� ..�q��i"� '*i'k'��6� ��'�'i�t�*'r,���d,`,,.r.,.,.�... . _. ,. � e,,.a°!�d5+�,� Water hardness Corrosion � Fill the system with clean water from the municipal � Damage to the system can occur when oxygen is water supply. introduced to the heating system water.The following � Consult your local water department for the level must be avoided for best system operation: of CaCO3 Ccalcium carbonate)to determine if water � Undersized or faulty expansion vessels treatment is necessary. � Open vented systems � Do not use water from salt bedding systems(ion � If the system can not be constructed as a sealed exchange)used to soften water. system, the use of a heat exchanger as a means of � Approved Anti-freeze(Aluminum safe) system separation is required. � Rhomar—Rhogard(at a concentration no more than Retrofit installations 60%by volume). � Installing a dirt trap such as a wye-strainer is required. It must be � Noble Company—Noburst-AL(at a concentration no installed in the immediate vicinity of the boiler on the retum pipe greater than 50°/o by volume). at the lowest point in the system. � Maintenance � Follow the instructions of the approved anti-freeze vendor.An annual visit by a qualified service technician is recommended. • • — JOTED. 'ION :SIZE CT. : . 10 " P1 : 6 " 0 . 10 " Q� : ........... ; ; - i � _. .............. . ...............: � , , , ,...... ...... BDD EF-2 NEW BOILER VENT UP TO THE RO 3 �.C?::: ° OF 1 :� ��" � O� H° > �., : :> ..;;� . :............................................................................................................................................................: : � EF-1 NEW BOILER VENT UP TO THE ROOF � NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES : �o�ro�vnQ, ' Town of Vail, Community Development,75 South Frontage Road,Vail, Colorado 81657 p. 970-479-2139 f.970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT Permit #: M08-0278 ACOM Project #: PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status. . . : ISSUED Location.....: RUCKSACK BUILDING Applied . . : 10/31/2008 Parcel No...: 210108244003 Issued. . . 11/18/2008 Expires. .: 05/17/2009 OWNER ROSENQUIST,RICHARD N.-BROW 10/31/2008 -SELBY,CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT CLIMATE CONTROL CO OF GWS 10/31/2008 Phone:970-945-2326 P O BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129-M CONTRACTOR CLIMATE CONTROL CO OF GWS 10/31/2008 Phone:970-945-2326 P O BOX 1042 GLENWOOD SPRINGS CO 81602 License: 129-M Desciption: RUCKSACK CORE/SHELL MECHANICAL PERMIT Valuation: $26,000.00 ....,�,�............».«.«..............................»...................,..*.:..FEE SUMMARY.�..............,�......................,.��...............«..........:..........,......., Mechanical Permit Fee---> $520.00 Will Call-----------> $4.00 Total Calculated Fees---> $654.00 ' Plan Check-------------> $130.00 Use Tax Fee------> $0.00 Additional Fees----------> $0.00 Investigation-------------> $0.00 TOTAL PERMIT FEE---> 5654.00 Total Calculated Fees--> $654.00 Payments---------------> 5654.00 BALANCE DUE-------> a0.00 .............................«....«.........,�.....................................................:..............«...:................,..»..».».....................................3..... APPROVALS Item:05100 BUILDING DEPARTMENT 10/31/2008 cgunion Action:CR need revised plans. scope of work was not approved with the core/shell permit 11/18/2008 cgunion Action:AP APPROVED REVISED MECHANICAL PLANS WITH THE BUILDING PERMIT. ►,t���w,ex*:fwx,eww,ew,mwwn,Her,rww«rtw,t�w��::w,t,rx*►►►,�,e**rvewww,rw►,�,rrw«warr�►sx,�*trt�e�::+�i#�+i+rt►�►*,t�r,t#*+n,tix►r**ww��,w«w��rws.��i�t#►*,t�*►x►,�►�**+,etr*xwr,e,t*��weken«�ew►.,r��v,e►w�rw��►*+►+wk CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond:22 (BLDG.):COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond:23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. Cond:25 (BLDG.):GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond:29 {BLDG.):ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC.. Cond:31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond:32 (BLDG.):PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond:30 mechcan ical_perm it_041908 (BLDG.):BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. ret�wrrtew�v,tw►�t,t,t�t+f*:*tR***��rtw+t+e+e+�ver**w�►►��t�t*�*�w►xwwrrrwwwrrrtw�k+�,t�,t►rt+.w�*►r�**fsint�**wwwwwwwwrw�w,tyww*,t►,�x►►�t�fwn►��wrtw�wwfew,t:���t,t�*�*�t�tn►�t►fr**wwxw�w,rwf�w�:t:,tt+*�s�**���trtrr*► DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FO INS ECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 PM. , � (/ 18 � Signature of ontractor Date �Av � 6J ,�. 2� c�4,P Print Name mechcan ical_pe rm it_041908 ***�************+******************s****************************************�***�**********r TOWN OF VAIL, COLORADO Statement �**�***************�**+****�******�*****************�********************+***�************** Statement Number: R080002216 Amount: $654.00 11/18/200802 :07 PM Payment Method: Check Init: DDG Notation: Climate Control Company 26033 ----------------------------------------------------------------------------- Permit No: M08-0278 Type: MECHANICAL PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $654 .00 This Payment: $654.00 Total ALL Pmts: $654 .00 Balance: $0.00 *********�*******��********************************�*****�****�**�*+*******************+**** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ MP 00100003111100 MECHANICAL PERMIT FEES 520.00 PF 00100003112300 PLAN CHECK FEES 130.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- � O�t, 30. 2008 10: 57AM CLIMATE CON��O� C�1�'rA11Y No, 8461 P, 1 ,..._, . ,..� � :��r.. � �-: , f.�i��,-�. `IC" 'n;��,�41 �'J�J. �,��7<�.�`!"� !`;'�''M��i L'� �' `'arr` .-...,,.'. � �^'�i~J.:'�j� 5��.1:�,S'��f r�`�,,`�M1�Cyl..� �WV��I,aWI ',� R'l �����!''.-. , , . .,,. " _�__ `�s,,,�Y`�`, � :�'•L " ,,'��"n ,;� -h=75�outti F ntage F� � �,�.. .�`��: � g �,,� � E, � � - '.%�- ��:'� �.,� v��L' �. ��.��a. - I f�. � .. ,.pe°d # :��.°�:-.�'4a�_ +.�.. . . •,,� p: � �`� �. � ._• �.. ir-- TOWN OF VAIL MECHANICAL PERMIT APPLICATION The followlns�Items MUST be attaehed to this certnit ao�llcatlpn Mechanica Rccm Lavout drawn to scale to Incfude: Mechanlcal Room Dlmensions Combustion Air Duct Size and Loc�tion p Flue,Vent and Gas Llne Slze and Location � Heat Loss Cakulations Equipment Cut/Spec Sheets PTOject Address ��Q� � /7t �l�(,�. Project t�: �J�� � _._.a,�.�. .��,,��E ��ZEE,-, vA►.� -aD BuildinA Permit#: _ � 7� Contractor Information �O�� D �1r'1Q /� /� Mechaniral Permif#: y �d Company: I..LJMA7� �1�1�L I�MPi�1/�Ly _--- ...... .. _ . . ...._ , ._.... pb �� `Q� � Detalled Dascrlptlon of Work: 1 1��� Company Address: r• , _ c�ry;r�C-�+�WGOD SP6�stete: C� z�P: 8� Ovi� r r�E A�P �UCT, EXNAU�� � ' Contea Neme; �v � � ��L-�� � a �c�-�a9 �u c� . �- �a� co i cs; Contact Ph: 9 45-a� 6 �e,�: a � �x�u5` F�A� i Gfl��SF.}�� �f��'117 E-Mail: 1�ZI _ `� CL�MATE C�'.y���G�.C_��'u1PAN'(�Use addltlonal sheet'rf necessary in/� r . .. ..... . ..-'...._._.. ................ ......... . .. . . . . .... . . � Tow Vail Contractor Registration N0, l d�l .C�. Complete Valuation for�anical Permit � � G� X L�`�--�` — Meehanical S �6� ��d, � Contractor Slgnature(required> !, ' ---._.._._....---....____ _ _ _ ,. . . . . Property Information work Class: Parcel�i: � (d I O 2��"�� ��� New� Addition( ) Remodel( ) Repair( )Other( ) 1 6oiler Location: legal Description:Lot# ( Blk# Intarior( ) Exterior( ) Other( ) A[L Vic.�AG� . ._ . . ..... . ...... .. .__ ._.. .. .. . ._. . . _. Subdivision:,�_ No/Type Exlating Ffreplaces: Job Name: �$� �Q11�E � EE� Gas Appliances( )Gas Logs( )Wood/Pellet( ) ..... __._. .. _._ _.... .. . .. � Owner Name: J E-F� �E�`� No�'Type Proposed Flreplaces: � Malling Addross: Gas Appliances( )Gss Logs( )Wood/Pellet( ) (FOr Pareel ii Contaa Eagle Counry assessors Office et 97o-328-86ao or vieit gullding Type: www.eaglacounty.us/patie) .. . _.._.. : .. _ . ,.. ._ Singl�Famlly( ) Two-Family( ) Mutti-FamilY( ) _ Arehitect( ) Dealgner( ) Englneer9C) Commerclal� Townhome( ) Other( ) Ne�: A�� Phone: q 7�' �$` �5 Z V _ _ Date Received: F�: 0 - � I �-M��i, � � NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES : �o�ro�vn¢ . �...,.�,.,,. ���_��a� Town of Vail,Community Development,75 South Frontage Road,Vail,Colorado 81657 p.970.479.2139 f.970.479.2452 inspections 970.479.2149 '�6�-6� � PLUMBING PERMIT Permit #: P08-0081 3a�-��2 ACOM Project #: PRJ07-0234 Job Address: 288 BRIDGE ST VAIL Status. . . : ISSUED location.....: RUCKSACK BUILDING Applied . . : 07/23/2008 Parcel No...: 210108244003 Issued. . : 07I31I2008 Expires . .: 01/27/2009 OWNER ROSENQUIST,RICHARD N.-BROW 07/23/2008 -SELBY,CHARLES 385 CLAYTON ST DENVER CO 80206-4228 APPLICANT SUNDANCE PLUMBING&HEATING 07/23/2008 Phone:970-748-8977 P.O.BOX 3684 AVON CO 81620 License: 101-P CONTRACTOR SUNDANCE PLUMBING&HEATING 07/23/2008 Phone:970-748-8977 P.O.BOX 3684 AVON CO 81620 License: 101-P Desciption: RUCKSACK REMODEL: ROUGH-IN PLUMBING FOR FUTURE TENANTS Valuation: $66,000.00 f*fr*x***:*3rrxvr�wxxnyrrvkxrrrr+rr►x�M,t*�*f.***�x*+f�*r�nrx**►*��*f�irt*f**�ewt��wr: FEE SUMMARY ••••••••••••••••••••••••*••••••••••••••••••••••••••••••••»••••••••»••••••••••••••• Plumbing Permit Fee—> $990.00 Will Call--------------> $4.00 Total Calculated Fees---> $1,241.50 Plan Check----------> $247.50 Use Tax Fee----------> $0.00 Additional Fees------------> $0.00 Investigation----------> $0.00 TOTAL PERMIT FEES--> a1,241.50 Total Calculated Fees--> $1,241.50 Payments--------------> 51,241.50 BALANCE DUE-----> a0.00 t t R+!4�M#R i*►J f�f##'f�t R###t�#1t 1t I f f�R#t R f i#Y M t t#**Y f r iF 4 4 4►t R R#A f f�#f tF#1 t�R t t}#i f R A R�R t�#11 t�*1��!R R R!t�#/�R i�f�t�#t####Q#Q Q#R t R M�R 0#R Y t W i W W#/t k t 1Y t#*#i#4 J i J A R t#i t 11r f i i t H f#f i�#i�f f f 11 f I e i!i�Y t�f f#i f f f t t f i f J i##t f f t t APPROVALS Item:05100 BUILDING DEPARTMENT 07/23/2008 JLE Action:AP fiRMltZf�it4YikYnYliFy'YrYnk�ffft+tR4}�tf44kH###f#RR4kRAA1'RRRRNitflfwfRiR4�RiRRf�Rfftr44Vfff�kYf�flf#R4t4Yf#4rtYrfffrt�k#Mff4rt1(�RttRfliY4fiRi�Rf�iff4tf�4R4/ffrlk4�4RR4lwf�ff}f4t�lf!}ff}}*R4ffffle V tef4ffte�+�fttxtrtr CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. 1ff�►ffiNlf�#AR►fRffiR#JtRRtRiYYttRA^RwtRff4f r�1'*4*#t#fiY4#44#fJffi�###*#iffi444it#f#Hf4##4Rtfi44fifAAt*###iN#*Itf#*t�#ffNfiRl4lf#44►t!!44#4#4ltitR#�kKR►1f�f�1�*ttRtltif#i#*R�kififttttf4Aft#f4i4ff DECLARATIONS I hereby acknowledge that I have read this application,filled out in full the information required,completed an accurate plot plan,and state that all the information as required is correct. I agree to comply with the information and plot plan,to comply with all Town ordinances and state laws,and to build this structure according to the towns zoning and subdivision codes,design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM-4 PM. � � Signature o wner or ontrac r te � Print Name plmbpermtl_041908 **+*******��*s*********************�***�***�**�***********�***r************�**********�***** TOWN OF VAIL, COLORADO Statement ***■********«*�***���+��****rr****r*««*********�**+��**.****+*****�*******�***************** Statement Number: R080001276 Amount: $1,241.50 07/31/200801:11 PM Payment Method: Check Init: DDG Notation: Sundance 2293 ----------------------------------------------------------------------------- Permit No: P08-0081 Type: PLUMBING PERMIT Parcel No: 2101-082-4400-3 Site Address: 288 BRIDGE ST VAIL Location: RUCKSACK BUILDING Total Fees: $1,241.50 This Payment: $1,241.50 Total ALL Pmts: $1,241.50 Balance: $0. 00 *******+***************************�**++*+************�*****************r****+************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 247.50 PP 00100003111100 PLUMBING PERMIT FEES 990.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ----------------------------------------------------------------------------- I I I I , � � � f � i � i � i I Nov-OT-OT 11:OOpe From-TONN OF VAII CO�MUNITY DEVELOPMENT 9T04T02452 T-115 P.002/003 F-298 APPLICATION WILL NOT BE ACCEP'TED IF INCOMPL�OR UNSIGNED P�J O� ,,,G�,�(L Pro�ect#: T Building Permit#: Z L �� �' , Plumbing Permit�#: — G ��.'�� '� � 970-479-2149(InspeCtiOns) 75 S.Frontage Rd. Vail, Colorado 81657 TOINN OF VAIL PLUMBING PERMIT APPLICATION CON'J'RACTOR INFORMATION Plumbing Contractor. Town of Vail Reg. No.: Contact PerSOn and Phone#'s; . . Y�� —t�Eg — 8�1Z7 E-Mail Address: F�uc#: Contracbor Sign ture: COMPLETE VALUATION FOR PLUMBING PERMIT(Labor 8k Materials) PLUMBING: $ � $ Co�et E I►e Coun A�ws OASic�s at 970-3I8-8640 or visit www.ea / cnun .cnm fbr Pa�c�e/� Parcel # 7ob Nam@; � 7ob Add�ss. � �- �S4 e-.. ,e. l.egal Description lo� Block: Filing: Subdivision: ' � Owners Name• ' Address: Phone: .� E�gineer: Address: Phone: Debiled description of,work: �� , �,n , � � � work class: IVew( ) addition ( ) Alteration(✓f Repair( ) other( ) Type of Bldg.: Single-family( ) Duplsu( ) Multi-fam�y( ) Cortunercial( Restaurant( ) Other( ) No.of Existing Dwelling Units in this buildir�g: N�.of AccommodaGon Units in this building: ,r,rw,�,�,r*,��,r�rr�*«ww�rww,rw»,e«�e***»t�tk-rxx**FOR OFFICE USE ONLY*re,r�r,r*w,rx*�er�v,r,�,r�r��,r**,�********,t,t�t��tt� .� ,.�.�,..�,.:.,,.M,�,�,..,,.,. >, , , ... , ,... .... �.���,,:,.., �Othe ees.}'.� ' •.y .L�!1 � �E� .,�:.:'.�, .;!ir;,�, ��*., tDa'te6rR�el�d:':�� �,,.�,.: ,,..x p,�;. ,.a.��„+7k�RMh'M► ;,;p'" s8':�,.-.,,, �.., � ,ir;t jn� ����� � � �� �2� i . so P:\cdev\fORM51PERM1'TS�Bufiding�plumbfng�Crmit 1i-23-2005.Oot v�ge i of� 11/Z3/Z005 _ ` � `�`�� ��' . �� � , 09-14-2009 Inspection Reque Re rting Page 9 4:32 Requested Inspect Date: Tuesday,September 15, 2009 Inspection Area: SH Site Address: 288 BRIDGE ST VAIL RUCKSACK BUILDING A/P/D Information Activity: E08-0104 Type: B-ELEC Sub Type: ACOM Status: ISSUED Const Type: Occupanc�r: Use: Insp Area: SH Owner: ROSENQUIST,RICHARD N.-BROWN, JEFFREY Contractor: BIG BEAR ELECTRIC, INC. Phone: 970-390-9221 Description: RUCKSACK REMODEL:TEMPORARY POWER Requested Insuection(s1 Item: 190 ELEC-Final Requested Time: 08:30 AM Requestor: BIG BEAR ELECTRIC, INC. Phone: 970-390-9221 Comments: WC 3909221 Assigned To: MDENNEY Entered By: CGUNION K Action: Time Exp: •�-S 4 ��s��-- �� L'�' \ � �l�o� Inspection Historv Item: 110 ELEC-Service **Approved*" 05/27/08 Inspector: shahn Action: PA PARTIAL APPROVAL Comment: temp power approved. Item: 120 ELEC-Rough 09/09/08 Ins ector: shahn Action: PI PARTIAL INSPECTION Comment: SO�FIT LIGHTS ROUGH-IN O. Item: 130 ELEC-Conduit Item: 140 ELEC-Misc. Item: 190 ELEC-Final I I I, I REPT131 Run Id: 10271 B08-0072: Entries for Item:90 - BLDG-Final 12:16 06/12/2013 Action Comments By Date Unique_ Ke AP Aproved per previuos inspections Martin 08/02/2012 A000152 764 Total Rows: 1 Page 1 P08-0081: Entries for Item:290 - PLMB-Final 12:18 06/12/2013 Action Comments By Date Unique_ Ke PA SHIRT OFF MY BACK EXISTING GCD 01/13/2009 A000121 RESTROOM AND NEW SLOP SINK. 886 PA APPROVED LORO PAINO JRM 03/09/2009 A000123 APPROVED RITZ 458 Total Rows:2 Page 1 M08-0278: Entries for Item:390 - MECH-Final 12:17 06/12/2013 Action Comments By Date Unique_ Ke CR NO PLANS FOR JOE'S GCD 11/26/2008 A000120 451 CR 1.FLANGE FIRE DAMPERS FOR JOE'S GCD 12/24/2008 A000121 DELI. 599 2.JOE'S FCU STILL HAS NO HYDRONIC HEAT SUPPLY. CR boiler#2 in place,but not operational. shahn 08/10/2009 A000126 reschedule ins ection of flue chase. 457 AP FINAL APPROVED BOILER#2 IS UNDER jrm 08/11/2009 A000126 ANOTHER PERMIT M08-0187 470 Total Rows:4 Page 1 M08-0187: Entries for Item:390 - MECH-Final 12:17 06/12/2013 Action Comments By Date Unique_ Ke � CR 1.BOILER COMBUSTION AIR PVC PIPE GCD 12/26/2008 A000121 REQD TO BE SAME SIZE AS VENT SEE 598 PAGE 25. 2.TERMINATE T&P VALVE. 3.FILL OUT COMMINISSIONING LOG. 4.INSTALL CONDENSATE NEUTRILIZER. 5.PVC IS STILL AGAINST SNOW MELT BOILER VENT. REQS 6"CLEARANCE TO COMBUSTIBLES. CR ITEMS 1,3,4 FROM 12-26-08 HAVE NOT GCD 01/06/2009 A000121 BEEN ADDRESSED. 764 ITEM 2 IS APPROVED. ITEM 5 THE PVC HAS BEEN CHANGED TO CAST IRON PIPE AT THE POINT OF CONTACT.SEE PAGE 25 GALVANIZED PIPE IS APPROVED.STATE BOILER INSPECTION IS REQD. NR GCD 01/13/2009 A000121 887 AP Martin 08/09/2012 A000152 945 Total Rows:4 Page 1