Loading...
HomeMy WebLinkAboutB08-0223APPROVALS Permit #: B08-0223 as of 09-17-2008 Status: ISSUED Item: 05100 BUILDING DEPARTMENT 07/24/2008 cgunion Action: CR F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0223\BO8-0223. DOC 09/05/2008 cgunion Action: AP APPROVED CORRECTED PLANS Item: 05400 PLANNING DEPARTMENT 07/30/2008 bgibson Action: AP Item: 05600 FIRE DEPARTMENT 07/10/2008 drhoades Action: AP Separate permit/shop drawings required for changes/additions to the existing monitored fire alarm system prior to any inspections occurring. **kkkk*k*kk*****************kkkkkkk*************kkkk*kkkk*kk**k*****k****kkkk**********kk*k********k**kk*kkkkkkk**k********kkkk*kkkk********kkkkkkkkkkkk******kkkkk*k*******k*kkkkk** See the Conditions section of this Document for any that may apply. bld_a It_con stru ction_perm it_041908 CONDITIONS OF APPROVAL Permit #: B08-0223 as of 09-17-2008 Status: ISSUED **k .......**##k*#**rt**rtrt#rt######k######rt#rt###rt#rtrtrtrt#rt##rtrt###rt###*#*#**#########*##*###***####* ***rt**rt#rt#rt*rtrt*rt*#*rt#rt#*#*rtrt*******#*#**#**********#**********rtrtrt##*#rtrt*#rtrt*k*** Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 16 (BLDG.): (SFR) SMOKE DETECTORS ARE REQUIRED PER SECTION R313 OF THE 2003 IRC. Cond: 18 (BLDG.): STAIRWAYS ARE REQUIRED TO MEET SECTION R311.5 OF THE 2003 IRC OR SECTION 1009 OF THE 2003 IBC. Cond: 19 (BLDG.): GUARDS ARE REQUIRED TO MEET SECTION R312 OF THE 2003 IRC OR SECTION 1012 OF THE 2003 IBC. Cond: 39 (BLDG): EMERGENCY ESCAPE AND RESCUE OPENINGS ARE REQUIRED TO MEET SECTION R310 OF THE 2003 IRC OR SECTION 1025 OF THE 2003 IBC. Cond: 34 (BLDG.): A COPY OF THE SOILS REPORT WILL BE REQUIRED BEFORE A FOOTING INSPECTION WILL BE CALLED FOR. b I d_a It_co n st ru ct i o n_pe rm it_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R080001670 Amount: $5,569.55 09/17/200802:02 PM Payment Method:Credit Crd Init: DDG Notation: credit card - Hedy Gurrentz ----------------------------------------------------------------------------- Permit No: B08-0223 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2103-124-0305-6 Site Address: 1465 GREENHILL CT VAIL Location: 1465 'A' GREENHILL COURT Total Fees: $6,579.49 This Payment: $5,569.55 Total ALL Pmts: $6,579.49 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 1,553.75 RF 11100003112700 RECREATION FEES 211.80 UT 11000003106000 USE TAX 4% 3,800.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 "ViKIL TOW F De velopment Review Coordinator 75 South Frontage Road Vail, CO 81657 Phone: 970-479-2128 Fax: 970-479-2172 Inspections: 970`-479-2149 BUILDING PERMIT APPLICATION Separate Permits are required for electrical, plumbing, mechanical, fireplace, etc. Project Address DRB# j?? 4l I??7(?? 'n f t' Project # 1 ?'?J 0 1 ?J^?? Contractor Information Building Permit #:-??1 7J ' L i 2i?i Company: ("wr r v,- e) 4'2, / T?SY Y °1 ee Detailed Description of Work: Company Address:, ??lnU S ?4S 1 U n 1 Company Ph: -b, ?" Z?o (g2//Fax: P C r D Contact Name: q J / Contact Ph: l / (Use additional sheet if necessary) E-Mail: De-0 1)V r 6 E-PLY, l- Ck U[ C-© I / / Architect () Designer () Engineer ( ) Town of V it Contractor Registration No: `? Phone: X ?Fax: COntractor tune re uir d J E-Mail: 9 ( 4 e ) Property Information2 Work Class: ) Parcel #: t/0. 0 New( ) Addition (t/ Remodel ( )Repair )Other( L gal Descriptidn: Lot ( Work Type: Interior( ) Exterior () Both (V) Subdivision: G_1'e-?\ G?.? ?7 !'1 Building Type: Job Name: Single-Family( ) Two-Family (" Multi-Family ( ) Owner Name: f?Q-? Y ?' ?'- >1 ?^ ?? ?l Z-; Commercial ( ) Townhome ( ) Other ( ) Mailing Address: a-b J ?-- # & Type of E ' ting Fireplaces: Gas Appliances (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or Gas Log (Wood/Pellet ( ) Wood Burning ( ) visit www.eaglecounty.us/patie) Valuations (Labor & Material) # & Type of P,rbposed Fireplaces: as ApOliances (Aw Gas Log ( Wood/Pellet ( ) Wood Burning T--)- Building $ O1 No ( Plumbing $ Does a Fire Alarm Exist: Ye?No( Monitored Alarm: Yes ( ) Electrical $ am" Does a Fire Sprinkler System Exist: Yes ( ) No l Mechanical $ Other $ Date Received D E C 1-9 ?/? , \VI IIREI?D Total $ JUL 0 3 2008 TOWN OP VAIL ******************************************************************************************** TOWN OF VAIL, COLORADO Statement ******************************************************************************************** Statement Number: R080001091 Amount: $1,009.94 07/03/200802:45 PM Payment Method: Check Init: JLE Notation: 3250 GURRENTZ ----------------------------------------------------------------------------- Permit No: B08-0223 Type: ADD/ALT SFR BUILD PERMIT Parcel No: 2103-124-0305-6 Site Address: 1465 GREENHILL CT VAIL Location: 1465 'A' GREENHILL COURT Total Fees: $6,367.69 This Payment: $1,009.94 Total ALL Pmts: $1,009.94 Balance: $5,357.75 ******************************************************************************************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 1,009.94 f2l REScheck Software Version 4.2.0 Compliance Certificate Energy Code: 2000 IECC Location: Vail, Colorado Construction Type: Single Family Glazing Area Percentage: 8% Heating Degree Days: 9248 Construction Site: Owner/Agent: Designer/Contractor: Ceiling 1: Cathedral Ceiling (no attic) 3500 53.0 0.0 70 Wall 1: Wood Frame, 16" o.c. 12000 21.0 0.0 616 Window 1: Metal Frame:Double Pane with Low-E 1000 0.350 350 Door 1: Solid 200 0.630 126 Basement Wall 1: Solid Concrete or Masonry 1200 13.0 0.3 247 Wall height: 9.0' Depth below grade: 4.0' Insulation depth: 4.0' Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 3000 36.0 0.0 84 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 4.2.0 and to comply with the mandatory requirements listed in the RRESc?chheck Inspection Checklist. t???- , 'Q--7,f n 'i - / 3'--- 711 Name - Title ` Signature Date Project Title: Report date: 09/03/08 Data filename: C:\Program Files\Check\REScheck\gurrentz\rescheck.rck Page 1 of 4 Compliance: Passes Compliance: 8.2% Better Than Code Maximum UA: 1627 Your UA: 1493 CNJ( REScheck Software Version 4.2.0 Inspection Checklist Ceilings: J1:eiling 1: Cathedral Ceiling (no attic), R-53.0 cavity insulation Comments: ,,?A"bove-Grade Walls: tx wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: Basement Walls: Basement Wall 1: Solid Concrete or Masonry, 9.0' ht / 4.0' bg / 4.0' insul, R-13.0 cavity + R-0.3 continuous insulation Comments: Exterior Insulation has a rigid, opaque, weather-resistant protective covering that covers the exposed (above-grade) insulation and extends at least 6 in. below grade. Windows: L3 Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes -Z Frame Type C1c-X Thermal Break? 1.1-* Yes Comments: Doors: L3/Door 1: Solid, U-factor: 0.630 Comments: No Floors: YFtoor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-36.0 cavity insulation Comments: Air Leakage: 2,- Joints, penetrations, and aA other such openings in the building envelope that are sources of air leakage are sealed. (3/ Recessed lights are 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, fixtures are installed with a 3" clearance from insulation. Vapor Retarder: Q%" Installed on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: Materials and equipment are installed in accordance with the manufacturer's installation instructions. 0 Q Materials and equipment are identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. Insulation is installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and In a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: J Ducts in unconditioned spaces are insulated to at least R-5. Ducts outside the building are insulated to at least R-8.0, quct Construction: All joints, seams, and connections are securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics are rated UL 181A or UL 181 B. Project Title: Report date: 09/03/08 Data filename: C:1Program FileslCheck\REScheckigurrentzlrescheck.rck Page 2 of 4 Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). 0 The HVAC system provides a means for balancing air and water systems. Temperature Controls: Thermostats exist for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor is provided. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: F-1 Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: Li All heated swimming pools have an on/off heater switch and a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps have a time clock. Heating and Cooling Piping Insulation: a- HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: Report date: 09/03/08 Data filename: C:\Program Files\Check\REScheck\gurrentz\rescheck.rck Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5' to 2.0" Over 2" Temperature ("F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Insulation Thickness in Inches by Pipe Sizes Piping System Types Fluid Temp. . Range("F) 2" Runouts 1" and Less 1.25' to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Project Title: Report date: 09/03/08 Data filename: C:\Program Files\Check\REScheck\gurrentz\rescheck.rck Page 4 of 4 r NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MEO VY Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 ELECTRICAL PERMIT Permit #: E08-0238?? ADUP Project #: PRJ07-0604 Job Address: 1465 GREENHILL CT VAIL Location.....: 1465'A' GREENHILL COURT Parcel No...: 210312403056 OWNER GURRENTZ, HEDY & KENNETH G. 10/06/2008 17706 E JAMISON AVE AURORA CO 80016 APPLICANT PIKE ELECTRIC 10/06/2008 Phone: (970) 390-7610 PO BOX 6158 AVON COLORADO 81620 License: 379-E CONTRACTOR PIKE ELECTRIC 10/06/2008 Phone: (970) 390-7610 PO BOX 6158 AVON COLORADO 81620 License: 379-E Desciption: WIRING FOR REMODEL Valuation: $7,000.00 Square feet: 1412 Status .. . Applied .. Issued. . . Expires. .: ISSUED 10/06/2008 10/06/2008 04/04/2009 FEE SUMMARY **** **w*?**.***, ....*.**.«**«*.**...**...*«„**«*..*w..w.. Electrical Permit Fee--------- > $57.50 Total Calculated Fees--> $61.50 Investigation Fee--------------> $0.00 Additional Fees ---------- > $0.00 Will Call Fee--------------------> $4.00 Use Tax Fee------------------- > $0.00 TOTAL PERMIT FEE---> $61.50 Total Calculated Fees ------- > $61.50 Payments --> $61.50 BALANCE DUE---------- > $0.00 ****************************************************************************************************************************************************************** APPROVALS Item: 06000 ELECTRICAL DEPARTMENT 10/06/2008 JLE Action: AP CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. Signature of Owner or Contractor f Date Print Name elec_prm_041908 A TOWN OF VAIL, COLORADO Statement Statement Number: R080001864 Amount: $61.50 10/06/200804:04 PM Payment Method: Cash Init: JLE Notation: PIKE ELECTRIC ----------------------------------------------------------------------------- Permit No: E08-0238 Type: ELECTRICAL PERMIT Parcel No: 2103-124-0305-6 Site Address: 1465 GREENHILL CT VAIL Location: 1465 'A' GREENHILL COURT Total Fees: $61.50 This Payment: $61.50 Total ALL Pmts: $61.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ EP 00100003111100 ELECTRICAL PERMIT FEES 57.50 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 T17WNOF?NI " Development Review Coordinator 75 South Frontage Road Vail, CO 81657 'Phone: 970-479-2128,,, Fax. 970-479-2172 Inspections` 970-479-2149 ELECTRICAL PERMIT APPLICATION Project Address IyCtS F' ILIl L L C lv Contractor Information h ,,ryry Company: b/XF- Company Address: v City: 4VrC State: CO Zip: e *,)- C Contact Name: F4 A,, iI/v/_ A ??c?k?eb ?L Contact Ph: Cell E-Mail: t74kKc I-11K ULP (0' Town of Vail Contracto egis tion No: X ?, Contractor Signature (required) Property Information Parcel #: -7 S Legal Description: Lot # Blk # Subdivision Job Name: ^- Owner Name:,! (,?QRL k; ?-- Mailing Address: (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) ) Architect( Name: Phone: Fax: E-Mail: Designer( ) Engineer( ) Project #: V`F_,) - CI ` -o Building Permit #: SQW -CMG 2_2, Q Electrical Permit #: L__ ; ?0 2 Detailed Description of Work: ??Ty?_O l (Use additional sheet if necessary) COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Material) Amount of SQ Ft /,/- / I Electrical $ .77L''00 Work Class: New ( ) Addition ( ) Remodel K Repair () Other ( ) Building Type: Single-Family) Two-Family ( ) Multi-Family ( ) Commercial ( ) Townhome ( ) Other ( ) Date Received: f? C , j? 6 _JOWNr-)F ?IAIL GG, NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT MWNOFVnII Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 p. 970-479-2139 f. 970.479.2452 inspections. 970.479.2149 MECHANICAL PERMIT ADUP Job Address: 1465 GREENHILL CT VAIL Location.....: UNIT A Parcel No...: 210312403056 OWNER GURRENTZ, HEDY & KENNETH G. 01/06/2009 17706 E JAMISON AVE AURORA CO 80016 APPLICANT WESTERN FIREPLACE SUPPLY, IN 01/06/2009 Phone: 668-3760 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323-M CONTRACTOR WESTERN FIREPLACE SUPPLY, IN 01/06/2009 Phone: 668-3760 1685 PAONIA COLO SPRINGS, CO 80915 PO BOX 670 MINTURN, CO 81645 License: 323-M Desciption: INSTALL GAS FIREPLACE INSERT (GAS PIPING BY OTHERS) Valuation: $4,286.38 ALL TIMES Permit #: M09-0004`-` z3 Project #: PRJ07-0604 Status ... Applied .. Issued. . . Expires . .: ISSUED 01/06/2009 01/08/2009 07/07/2009 rtrt*****#*# .#****rt***************** *****##*rtrt. ************#*******FEE SUMMARY**#*******************************#*********************# ?***..,. .*##**rtrt Mechanical Permit Fee---> $100.00 Will Call ------------ > $4.00 Total Calculated Fees ---> $129.00 Plan Check ------------------- > $25.00 Use Tax Fee------ > $0.00 Additional Fees-----------> $0.00 Investigation- ------> $0.00 TOTAL PERMIT FEE---> $129.00 Total Calculated Fees--> $129.00 Payments-----------------> $129.00 BALANCE DUE--------- > $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 01/06/2009 JLE Action: AP CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: CON0010517 SEPARATE PERMIT REQUIRED FOR GAS PIPING. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INS E I ALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0t AM - 4 PM. 01 /08169 / Si afuk of Ratner or Contractor Date mechcanical_permit_041908 TOWN OF VAIL, COLORADO Statement Statement Number: R090000025 Amount: $129.00 01/08/200902:55 PM Payment Method: Check Init: DDG Notation: Western Fireplace 2211 ----------------------------------------------------------------------------- Permit No: M09- 0004 Type: MECHANICAL PERMIT Parcel No: 2103 -124-0305-6 Site Address: 1465 GREENHILL CT VAIL Location: UNIT A Total Fees: $129.00 This Payment: $129.00 Total ALL Pmts: $129.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description --- ---- Current Pmts ------------ ----------------- MP 00100003111100 --- ---------------------- - MECHANICAL PERMIT FEES 100.00 PF 00100003112300 PLAN CHECK FEES 25.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 Development Review Coordinator 75 South Frontage Road Vail, GO 81657 Phone: 970-479-2.128 Fax: 970-479-2172 ' Inspections: 970-479-2149 1V((1} Ul" ll iiiJ k TOWN OF VAIL MECHANICAL PERMIT APPLICATION The followina items MUST be attached to this oermit aoDlication Mechanical Room Lavout drawn to scale to include: _ Mechanical Room Dimensions _ Combustion Air Duct Size and Location Flue, Vent and Gas Line Size and Location _ Heat Loss Calculations Equipment Cut / Spec Sheets Project Address o0 146S Gv"Eu ill U. Contractor' Information Company: W?.SW t . N? 01 ACC_ U Company Address: I b.S PAf, OlA Project #: Building Permit#: `Foezle,-10:2 Mechanical Permit #: i l ? - VQ ?T Detailed Description of Work: City: CdO SV_J2-'oN State: CU Zip: R()21S Contact Name: P/ L IRICF Contact Ph: Cell: qqs - 1168 E-Mail: ?{ Town of Vail on cy? egistration No: 3o13- M X I Contractor ignature (required) Property Information l? L Parcel #: a I o3 - v3 ' a S Legal Description: (Lot # -l . / Blk # Subdivision: Q s N l yb/Y Job Name: f I_ Owner Name: GuR R E N 1Z ?K6dy ?W Frl Mailing Address: t S. S Al Jt. (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie)6C6,CN I[0001d Vj IAQ (_ CO Architect () Designer () Engineer () ?? I I Name: Phone: Fax: E-Mail: IP-01 .oo INSWIA?_/UN 0 ONE ?XS cic ? IN&'a (Use additional sheet if necessary) Complete Valuation for Mechanical Permit: Mechanical $ 4 9(43 . .2?X0 Work Class: New ( ) Addition ( ) Remodel X Repair ( ) Other ( ) Boiler Location: Interior ( ) Exterior ( ) Other ( ) No/Type Existing Fireplaces: Gas Appliances(X) Gas Logs ( ) Wood/Pellet ( ) No/Type Proposed Fireplaces: Gas Appliances() Gas Logs ( ) Wood/Pellet ( ) Building Type: Single-Family Two-Family ( ) Multi-Family ( ) Commercial ( ) Townhome ( )) Other 7( ) Date Receive E ? IF o V n JAN -6 2009 TOWN OF VAIL NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MWNO M Town of Vail, Community Development, 75 South Frontage Road, Vail, Colorado 81657 z? p. 970.479.2139 f. 970.479.2452 inspections 970.479.2149 C) PLUMBING PERMIT Permit #: P08-0136 O ASFR Project #: w-3a-, _cyc)u? Job Address: 1465 GREENHILL CT VAIL Status ...: ISSUED Location.....: 1465 'A' GREENHILL COURT Applied ..: 10/16/2008 Parcel No...: 210312403056 Issued. .. 10/16/2008 Expires. .: 04/14/2009 OWNER GURRENTZ, HEDY & KENNETH G. 10/16/2008 17706 E JAMISON AVE AURORA CO 80016 APPLICANT HABITAT DESIGN GROUP 10/16/2008 Phone: 303-443-5402 ROBERT MOORE 3393 IRIS #110 BOULDER CO 80301 License: 0000002409 CONTRACTOR PLUMBING SYSTEMS, INC. 10/16/2008 Phone: 970-390-7763 PO BOX 3879 AVON COLORADO 81620 License: 277-P Desciption: reconfigure master bath. tub to showerADDITION OF GRFA Valuation: $15,000.00 *rtrt******#*********###********##********** R***#***# .*****##*** FEE SUMMARY ********* ********* ***************#************** *******#*******#* Plumbing Permit Fee---> $225.00 Will Call ----------> $4.00 Total Calculated Fees ---> $285.25 Plan Check ---------------- > $56.25 Use Tax Fee-- > $0.00 Additional Fees ------------ > $0.00 Investigation--------------> $0.00 TOTAL PERMIT FEES--> $285.25 Total Calculated Fees--> $285.25 Payments----------- > $285.25 BALANCE DUE-----------> $0.00 APPROVALS Item: 05100 BUILDING DEPARTMENT 10/16/2008 JRM Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTIQ?I SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 970.479.2149 OR AT OUR OFFICE FROM 8:0( AM - 4 PM. /7 Signatur¢ of 904r or Contractor ` Date Print Name v plmbpermt1_041908 i Deve opment Review Coordinator 75 South Frontage Road Vail, CO 81057 Phone: 970-479-21128 Fax: 970-47972172 k ' Inspections: 970-479-2149 TOWN OF VAIL LUMBING PERMIT APPLICATION Project Address: lcles- S = c.,i h C? Project #: s / „ /L Building Permit #: /,?Sr - 0--z z,3 (? /'j Plumbing Permit #: pV e -0 I3( Contractor Information Architect ( ) Designer ( ) Engineer ( ) Company: Name: Phone: Company Address: _/7.?S, 1z Fax: City: State Zip: E-Mail: Contact Name: Contact Ph: _4_L(i --7_ 0 Cell: E-Mail: s? Town of V?Vl ractor Registration No: l X Co or Sig ure (rey?fired) `' Plumbing Valuation (Labor & Material) _ Plumbing $ /J.' &-X) Detailed Description of Work: - ?`?""?•cu'e (Use additional sheet if necessary) Work Class: New ( ) Addition ( Remodel ) Repair ( ) Other ( ) Property Information Parcel #: Legal Description: Lot # Blk # Subdivision: Job Name: Ue r . Owner Name: Mailing Address: (For Parcel # Contact Eagle County assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) ? ?005. q4",G Building Type: ) Single-Family4--)j Two-Family ( ) Multi-Family( Commercial( ) Townhome ( ) Other( ) Date Received: 'D L?C?Is?V?G OCT 16 2008 D .__?OWN OF VAIL f **?k####?k ?k ?k####**#?k#ek##ek####***#*##***###?k***#*#*####**ok ?k###?k***###ek****#*?k*####*#########*?k* TOWN OF VAIL, COLORADO Statement Statement Number: R080001968 Amount: $285.25 10/16/200804:15 PM Payment Method: Check Init: JLE Notation: 3846 PLUMBING SYSTEMS INC ----------------------------------------------------------------------------- Permit No: P08-0136 Type: PLUMBING PERMIT Parcel No: 2103-124-0305-6 Site Address: 1465 GREENHILL CT VAIL Location: 1465 'A' GREENHILL COURT Total Fees: $285.25 This Payment: $285.25 Total ALL Pmts: $285.25 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ PF 00100003112300 PLAN CHECK FEES 56.25 PP 00100003111100 PLUMBING PERMIT FEES 225.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 01-30-2009 Inspection Request Reporting Page 1 4:09 I,m Vail, CO - City Of Requested Inspect Date: A i d T Friday, January 30, 2009 GDENCKLA ss gne o: Inspection Type: BLDG Inspection Area: JRM Site Address: 1465 GREENHILL CT VAIL 1465'A' GREENHILL COURT A/P/D Information Activity: B08-0223 Type: A-BUILD Sub Type: ASFR Const Type: O Occupancy: HEDY & KENNET GURRENTZ G Use: IRC wner: , H . Contractor: GURRENTZ, HEDY & KEN Phone: (303) 690-6711 Description: ADDITION OF GRFA Requested Inspection(s) Status: FINAL Insp Area: JRM Item: 90 BLDG-Final Requested Time: 08:30 AM Requestor: GURRENTZ, HEDY & KEN Phone: (303) 690-6711 Assigned To: GDENCKLA Entered By: BELLM K Action: Time Exp: Comment: unit was completed before the hoildays. No tinal inspection, unit remains occupied and appears to be complete. Insuection History Item: 30 BLDG-Framing Approved 10/16/08 Inspector: JGG Action: AP APPROVED Comment: Framing in remodel areas OK. Item: 50 BLDG-Insulation ** Approved ** 10/30/08 Inspector: JRM Action: AP APPROVED Comment: Item: 60 BLDG-Sheetrock Nail ** Approved ** 10/30/08 Inspector: JRM Action: AP APPROVED Comment: Item: 70 BLDG-Misc. Item: 534 PLAN -FINAL C/O Item: 90 BLDG-Final ** Approved ** 01/30/09 Inspector: JGG Action: AP APPROVED Comment: Unit was completed before the hoildays. No final inspection, unit remains occupied and appears to be complete. REPT131 Run Id: 9081