Loading...
HomeMy WebLinkAboutRAMSHORN Sprinkler heads freedom® residential concealed pendent sprinkler vk456 (K4.9) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK456 is a small highsensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a lowprofile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to ½” (12.7 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cULus Listed: Category VKKW NYC Approved: MEA 89-92-E, Volume 36 NSF Certified: NSF/ANSI Standard 61, Drinking Water System Components Refer to the Approval Chart on page 147g and Design Criteria on page 147h for cULus Listing requirements that must be followed. 3. technical data Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Patents Pending Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Seat Assembly: Brass UNS-C31600 Compression Screw: Brass UNS-C36000 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Form No. F_103105 Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Sprinkler 147e Replaces page 147e-j, dated April 3, 2009. (Revised minimum and maximum dimensions in Figure 2.) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com freedom® residential concealed pendent sprinkler vk456 (K4.9) Ordering Information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK456 and Cover Plate Assembly must be ordered separately: Sprinkler: Part No. 13620AJ (includes a 140 °F (60 °C) rated sprinkler with a protective plastic cap covering the unit). Cover Plate Assembly: Base Part No. 13750 (2-3/4” diameter), Base Part No. 14934 (3-5/16” diameter), or Base Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 135°/57° = A For example, cover 13750 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13750FA. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 13623W/B (available since 2006), or B. Head Cabinet Wrench Part No. 13619*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the fusible element to disengage, releasing the deflector and sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Sprinkler Model VK456 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 147f TABLE 1: AVAILABLE SPRINKLER TEMPERAT URE RATIN GS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Temperature Rating of the Cover Assembly (Required) Cover Plate Base Part Number3 Large Cover Plate Base Part Number3 Square Cover Plate Base Part Number3 Ordinary 140 °F (60 °C) 100 °F (38 °C) 135 °F (57 °C) 13750 14934 15394 Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. freedom® residential concealed pendent sprinkler vk456 (K4.9) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart Residential Concealed Pendent Sprinkler VK456 For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria on page 147h. Sprinkler Base Part Number1 SIN NPT Thread Size Nominal K-Factor Maximum Water Inches mm U.S. metric2 Working Pressure 13620A VK456 1/2 15 4.9 70.6 175 psi (12 bar) Maximum Areas of Coverage7 Minimum Water Supply Requirements7 Listings and Approvals3 (Refer also to Design Criteria on page 147h.) cULus4 NYC5 NSF6 Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5°). 12 ft. x 12 ft. (3.7 m x 3.7 m) 13 gpm @7.0 psi (49.2 L/min @0.48 bar) AX1 AX1 AX1 14 ft. x 14 ft. (4.3 m x 4.3 m) 13 gpm @7.0 psi (49.2 L/min @0.48 bar) AX1 AX1 AX1 16 ft. x 16 ft. (4.9 m x 4.9 m) 14 gpm @8.2 psi (53.0 L/min @0.56 bar) AX1 AX1 AX1 18 ft. x 18 ft. (5.5 m x 5.5 m) 17 gpm @12.0 psi (64.4 L/min @0.83 bar) AX1 AX1 AX1 20 ft. x 20 ft. (6.1 m x 6.1 m) 23 gpm @22.0 psi (87.1 L/min @1.52 bar) AX1 AX1 AX1 Installed below ceilings with slopes8 up to and including a 8/12 (33.7°) pitch. Refer to Figure 5 on page 147j. UL NYC NSF6 16 ft. x 16 ft. (4.9 m x 4.9 m) 17 gpm @12.0 psi (64.4 L/min @0.83 bar) AX1 --AX1 20 ft. x 20 ft. (6.1 m x 6.1 m) 26 gpm @28.2 psi (98.4 L/min @1.94 bar) AX1 --AX1 Sprinkler Temperature Ratings A -140 °F (60 °C) Cover Temperature Rating X -135 °F (57 °C) 137501, 149341 (large diameter), or 153941 (square cover plate) Cover Plate Finishes 1 -Polished Chrome, Painted White, Painted Ivory, and Painted Black9 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 5 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 36. 6 Tested and Certified by NSF (National Sanitation Foundation) to NSF/ANSI Standard 61, Drinking Water System Components. 7 For areas of coverage smaller than shown, use the “Minimum Water Supply Requirement” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the “Minimum Water Supply Requirement” used. 8 Areas under sloped ceilings must be measured along the ceiling slope. Actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area of coverage. 9 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. ������������������������������������������������������������������������������������ Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. Sprinkler 147g TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com freedom® residential concealed pendent sprinkler vk456 (K4.9) Sprinkler 147h DESIGN CRITERIA (Also refer to the Approval Chart on page 147g.) cULus Listing Requirements: When using Viking Residential Concealed Pendent Sprinkler VK456 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 147g. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart on data page 147g for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. ••• IMPORTANT : Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 1: Sprinkler Installation and Correct Use of Wrenches freedom® residential concealed pendent sprinkler vk456 (K4.9) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler 147i Figure 2: Sprinkler Dimensions and Cover Installation Figure 3: Identification of Custom Paint Color for Concealed Covers Figure 4: Square Cover Assembly 15394 TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com freedom® residential concealed pendent sprinkler vk456 (K4.9) Form No. F_103105 Sprinkler 147j Figure 5: Installation Instructions -Sloped Ceilings Notes: 1. Listed areas of coverage correspond to areas measured along ceiling slope. (For sloped ceiling installations, actual floor coverage in the horizontal plane under sloped ceilings will be less than the listed area.) 2. Actual installations may require multiple sprinklers. A single sprinkler installation has been shown for clarity. 3. For “cathedral” ceiling applications, install sprinklers in a symmetrical mirror-image of Figure 5. Refer to the Approval Chart for listed areas of coverage. Maximum ceiling slope = 8/12 (33.7°). See Note 1 below. Replaces page 147e-j, dated April 3, 2009. (Revised minimum and maximum dimensions in Figure 2.) mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Mirage® Standard and Quick Response Concealed Pendent Sprinkler VK462 and HP Sprinkler VK463 are thermosensitive glass-bulb spray sprinklers designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to ½” (12.7 mm) of vertical adjustment. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on”, “thread-off” design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approval: Class 2015 NYC Approved: MEA 89-92-E, Volume 32 VdS Approved: Certificate G4080021 LPC Approved: Ref. No. 096e/12 CE Certified: Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2032 and 0786-CPD-40249 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be followed. 3. technical data Specifications: Available since 2006. Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17.2 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. Sprinkler VK462 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2” (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metric†) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Patents Pending *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The mi���������������������������������nimum operating pressure for LPCB�� a�������nd CE Approvals ONLY is 5 psi (0.35 bar). †Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector: Copper UNS-C19500 for Sprinkler VK462 Phosphor Bronze UNS-C51000 for Sprinkler VK463 Deflector Pins: Stainless Steel Alloy Bulb: Glass, nominal 3 mm diameter Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Sprinkler 54a TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6) Cover Assembly Materials: Cover: Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs: Nickel Alloy Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage® Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix (°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E For example, sprinkler VK463 with a 155 °F/68 °C temperature rating = 13667AB. Cover Plate Assembly: Base Part No. 13504 (2-3/4” diameter), Base Part No. 13642 (3-5/16“ diameter), or Base Part No. 15394 (square cover plate, 3-5/16” diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black = M-/SW1007 Temperature Suffix (°F/°C): 135°/57° UL (139°/59° FM) = A, 165°/74° = C For example, cover 13504 with a Polished Chrome finish and a 165 °F/74 °C temperature rating = 13504FC. Note: Square cover plate 15394 cULus Listing is for the 135 °F (57 °C) temperature rated cover plate only. Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part No. 14412 for cover 13504, or Part No. 14867 for the large diameter cover (available since 2007) **Requires a ½” ratchet (not available from Viking). ***Optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: five (5) sprinklers (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the yoke, pip-cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Sprinklers VK462 and VK463 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 54b mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart Mirage® Concealed Pendent Sprinklers VK462 and VK463 Sprinkler Base Part No.1 SIN NPT Thread Size Nominal K-Factor Maximum Water Working Pressure Listings and Approvals4 (Refer also to Design Criteria on page 54d.) Inch mm U.S. metric2 cULus5 FM NYC6 VdS LPCB Standard Response Applications 13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) --AU1, BX1 --AY1, CZ1 ----14697A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) --------AV2, BW2 AV2, BW27 Quick Response Applications 13503A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 --AV1, BW1 ----AY2, CZ28 14697A VK462 1/2” 15 5.6 80.6 175 psi (12 bar) AV1, BX1 --AV1, BW1 ------13667A VK463 1/2” 15 5.6 80.6 250 psi (17.2 bar)3 AV1, BX1 --AV1, BW1 ------Sprinkler Temperature Ratings A -155 °F (68 °C) B -175 °F (79°C) and 200 °F (93 °C) C -200 °F (93 °C) Cover Plate Assembly Temperature Ratings9 U -���������������������������������������135 °F (57 °C) cULus Listed cover 135041, 136421 (large diameter), or 153941 (square cover plate) FM Approved as 139 °F (59 °C) V -���������������������������������������135 °F (57 °C) cULus Listed cover 135041 or 136421 (large diameter) W -165 °F (74 °C) cover 135041 or 136421 (large diameter) X -��������������������������165 °F (74 °C) cover 135041, 136421 (large diameter), or �����153941 (square cover plate) Y -135 °F (57 °C) cover 135041 Z -165 °F (74 °C) cover 135041 Cover Plate Assembly Finishes10 1 -Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 2 -Polished Chrome, Painted White Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 The Water Working Pressure rating is stamped on the deflector. 4 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 5 Listed by Underwriter’s Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 32. 7 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40249. 9 The 135/139 °F cover has an orange label. The 165 °F cover has a white label. 10Painted finish consists of Polyester Baked Enamel. �������������������������������������������������������������������������������������������������Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information.�� NOTE: Custom colors are indicated on a label inside the cover assembly. Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERAT URE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Temperature Rating of Cover Assembly (Required) Bulb Color Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) cULus 139 °F (59 °C) FM Red Intermediate 175 °F (79 °C) 150 °F (65 °C) 165 °F (74 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific specific installation standards. Sprinkler 54c TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6) Sprinkler 54d DESIGN CRITERIA (Also refer to the Approval Chart on page 54c.) cULus Listing Requirements: Mirage® Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. For hazard occupancies up to and including Ordinary Hazard, Group II. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Maximum spacing allowed is 15 ft. (4.6 m). Minimum spacing allowed is 6 ft. (1.8 m) unless baffles are installed in accordance with NFPA 13. Minimum distance from walls is 4 in. (102 mm). Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler obstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklers must be followed. N����������������������������������������� ������������������������������������������������OTE: Concealed sprinklers m��������������������������������������������������������������ust be installed in neutral or negative pressure plenums only. •••••• FM Approval Requirements: Mirage® Concealed Pendent Sprinkler VK462 is FM Approved as a standard response standard spray sprinkler as indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT : Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to page SR1-3 or QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA , FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Figure 1: Identification of Custom Paint Color for Concealed Covers Figure 2: Square Cover Assembly 15394 mirage® standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6) TECHNICAL DATA August 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler 54e Figure 4: Sprinkler Dimensions and Cover Installation Figure 3: Sprinkler Installation and Correct Use of Wrenches Form No. F_103005 THISPAGEINTENTIONALLY LEFT BLANKReplaces page 54a-e, dated June 5, 2009. (Revised minimum and maximum dimensions in Figure 4). MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA April 25, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers available in several different finishes, temperature ratings, and K-Factors to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E, Volume 16 ABS Certified: Certificate 04-HS407984B-PDA VdS Approved: Certificate G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved: Ref. No. 096e/03, TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, and 0786-CPD-40171 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 51d and Design Criteria on page 51e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifi cations: Available since 1987. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: Refer to the Approval Chart Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C23000 or Copper UNS-C19500 for Sprinklers 06661B and 12281. Copper UNS-C19500 for Sprinklers 06665B, 06764B, and 07060. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated Form No. F_080488 Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Sprinkler 51a Replaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) TECHNICAL DATA April 25, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 06661BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 51b MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA April 25, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51d. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Sprinkler 51c Figure 1: Standard Sprinkler Wrench 10896W/B TECHNICAL DATA April 25, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS Approval Chart Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers Maximum 175 PSI (12 bar) WWP Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 51e.) NPT BSP U.S. metric2 Inches mm cULus4 FM7 NYC8 VdS LPCB Upright-Standard Orifice 06661B VK300 1/2” 15 mm 5.6 80.6 2-3/16 56 A2 A3 A2 --------07060 VK345 --15 mm 5.6 80.6 2-3/16 56 --A3 --A3 A3 B312 B314 Conventional-Standard Orifice 06766B VK310 1/2” 15 mm 5.6 80.6 2-3/16 56 A3 --A3 --A3 B312 B314 Upright-Large Orifice 06665B VK350 3/4” --8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 B312 --14817 VK350 --20 mm 8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 B312 --06764B VK350 1/2” 15 mm 8.0 115.2 2-5/16 59 A2 --A2 A3 ------Conventional-Large Orifice 06768B VK354 3/4” 20 mm 8.0 115.2 2-5/16 59 A2 --A3 --A3 B312 --Upright-Small Orifice10 06717B11 VK325 1/2” 15 mm 2.8 40.3 2-3/16 56 A2 A1 A2 --------06719B11 VK327 1/2” 15 mm 4.2 60.5 2-3/16 56 A2 --A2 --------06931B11 VK327 --10 mm 4.2 60.5 2-3/16 56 ------A3 --E113 --Maximum 250 PSI (17 bar) WWP Upright-Standard Orifice Base Part Number1 SIN Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on page 51e.) NPT BSP U.S. metric2 Inches mm cULus4 FM NYC9 VdS LPCB 12281 VK315 1/2” 15 mm 5.6 80.6 2-3/16 56 A2 --A2 --------Upright-Small Orifice10 1228611 VK340 1/2” 15 mm 2.8 40.3 2-3/16 56 A2 --A2 --------Approved Temperature Ratings A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) B -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) C -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F (141°C) D -135 °F (57 °C), 155 °F (68 °C), and 175 °F (79 °C) E -155 °F (68 °C) Approved Finishes 1 -Brass and Chrome-Enloy® 2 -Brass, Chrome-Enloy®, White Polyester5,6, Black Polyester5,6, and Black Teflon®5 3 -Brass, Chrome-Enloy®, White Polyester5,6, and Black Polyester5,6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 cULus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 7 For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA. 9 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied, with hydraulically calculated wet systems only. Exception: 4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 11The sprinkler orifice is bushed. 12 Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 Certified, Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 14 MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. Sprinkler 51d MICROFAST® AND MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS TECHNICAL DATA April 25, 2008 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler 51e DESIGN CRITERIA (Also refer to the Approval Chart on page 51d) cULus Listing Requirements: Microfast® and MicrofastHP® Quick Response Upright and Conventional Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style (conventional) sprinklers. Designed for use in Light and Ordinary Hazard occupancies (exception: small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. For conventional sprinklers, refer to the installation guidelines for old style (conventional) sprinklers. •• FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_080488 THIS PAGE INTENTIONALLY LEFT BLANKReplaces page 51a-e, dated March 7, 2008. (Updated LPCB Approval on Sprinkler 14817.) microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester and Teflon® coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart. (Note: FM Global has no approval classification for Teflon® and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: MEA 89-92-E, Volume 16 Refer to the Approval Chart on page 43d and Design Criteria on page 43e for cULus and FM approval requirements that must be followed. 3. technical data Specifications: Available since 2003. Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: Sprinkler VK319 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP) sprinklers can be identified by locating “250” stamped on the deflector. Sprinkler VK305 is rated to a maximum 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Nominal K-Factor: 5.6 U.S. (80.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-11/16” (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap: Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment: Brass UNS-C36000 For Teflon® Coated Sprinklers: Belleville Spring-Exposed, Screw-Nickel Plated, Pip Cap-Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-/W, Black Polyester = M-/B, and Black Teflon® = N Temperature Suffix (°F/°C): 135°/68° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK305 with a Brass finish and a 155 °F/68 °C temperature rating = Part No. 12121AB Form No. F_030103 Viking Technical Data may be found on The Viking Corporation’s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Sprinkler 43a Replaces page 43a-f, dated March 2, 2007. (Revised FM Design Criteria. Added the Model G-1 Escutcheon.) TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the “Sprinkler Accessories” section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). B. Wrench for recessed sprinklers with protective shields: Part No. 13655W/B** (available since 2003) **A ½” ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B. Twelve-head capacity: Part No. 01725A (available since 1971) 4. Installation Refer to appropriate NFPA Installation Standards. 5. Operation During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. inspections, tests and maintenance Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. availability Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. Guarantee For details of warranty, refer to Viking’s current list price schedule or contact Viking directly. Sprinkler 43b Figure 1: Standard Sprinkler Wrench 10896W/B microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATIN GS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. Sprinkler 43c Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) Approval Chart Microfast® and MicrofastHP® Quick Response Horizontal Sidewall Sprinklers Base Part Number1 SIN Maximum Pressure Thread Size Nominal K-Factor Overall Length Listings and Approvals3 (Refer also to Design Criteria on pg 43e.) NPT BSP U.S. metric2 Inches mm cULus4 FM NYC5 LPCB Maximum 175 PSI (12 Bar) WWP For Light or Ordinary Hazard Occupancies. Deflectors must be located 4” to 12” (102 mm to 305 mm) below the ceiling. 12121 VK305 175 psi 1/2” 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X --A1Y ------Maximum 175 PSI WWP For Light Hazard Occupancies Only. Deflectors must be located 4” to 6” (102 mm to 152 mm) below the ceiling. 12121 VK305 175 psi 1/2” 15 mm 5.6 80.6 2-11/16 68 cULus FM6 NYC LPCB A1Y, B1X A2Y, B2Z --------Maximum 250 PSI WWP For Light or Ordinary Hazard Occupancies. Deflectors must be located 4” to 12” (102 mm to 305 mm) below the ceiling. 12285 VK319 250 psi 1/2” 15 mm 5.6 80.6 2-11/16 68 cULus4 FM NYC5 LPCB A1Y, B1X --A1Y ------Approved Temperature Ratings A -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141 °C) B -135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 200 °F (93 °C) Approved Finishes 1 -Brass, Chrome-Enloy®, White Polyester7, Black Polyester7, and Black Teflon®7 2 -Brass Approved Escutcheons X -Installed with standard surface-mounted escutcheons or the Viking Microfast® Model F-1 Adjustable Escutcheon8, or recessed with the Viking Micromatic® Model E-1, E-2 or G-1 Recessed Escutcheon Y -Installed with standard surface-mounted escutcheons or the Viking Microfast® Model F-1 Adjustable Escutcheon8 Z -Installed with the Viking Model G-1 Recessed Escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking’s current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Other approvals may be in process. 4 Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 5 Accepted for use, City of New York Department of Buildings, MEA 89-92-E, Vol. 16. 6 FM Approved for installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 7 cULu s Listed as corrosion-resistant. ��������������������������������������������������������������������������������������������������Other colors are available on request with the same Listings and Approvals as the standard colors. 8 The Viking Microfast® Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. Sprinkler 43d microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on page 43d.) cULus Listing Requirements: Quick Response Horizontal Sprinklers VK305 and VK319 are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate the deflector 4” to 12“ (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4” (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. •••••••• FM Approval Requirements: Install in accordance with the latest applicable FM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT : Always refer to Bulletin Form No. F_091699 -Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA , FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler 43e Figure 3: Sidewall Sprinkler VK305 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon TECHNICAL DATA February 13, 2009 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com microfast® and microfasthp® quick response horizontal sidewall sprinklers (vk305 & vk319) Sprinkler 43f Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_030103 Replaces page 43a-f, dated March 2, 2007. (Revised FM Design Criteria. Added the Model G-1 Escutcheon.) Figure 5: Sidewall Sprinkler VK305 Dimensions with the Model G-1 Recessed Escutcheons