Loading...
HomeMy WebLinkAboutB06-0145.PDF _ _ -� � , �� i M ichael Folwell , Architecture � , GENERAL NOTES DRAWING SYMBOLS �- C LA G G ETT- R E Y G A L L E R Y �31 CRESCENT DR 1 ALL WORK PERFORMED, INCLUDING MATERIALS FURNISHED, WORKMANSHIP, MEANS AND METHODS OF BOULDER, CO USA CONSTRUCTION SHALL CONFORM THE APPLICABLE AND LATEST REQUIREMENTS OF THE NATIONAL, STATE AND ROOM NUMBER &NAME DEfAIL REFERENCE LIST OF D RAW I NGS 80303 LOCAL BUILDING CODES, ALL LOCAL AND STATE HANDICAP ACCESS AND USE REGULATIONS, ANY FIRE DEPARTMENT REGULATIONS, UTILITY COMPANY REQUIREMENTS, LANDLORD'S RULES AND REGULATIONS, AND GENERAL CONDITIONS q Sh2�t# R E M O D E L phone 720-304-8082 OF APPLICABLE OWNER/CONTRACTOR AGREEMENT q_211 fax 303-499-4337 2 BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED CERTIFICATES OF INSURANCE WITH T-1 1 Projectda�a,General I�forma�on, folwell studios com THE OWNER, LANDLORD AND THE BUILDING DEPARTMENT, OBTAINED ALL REQUIRED PERMITS, AND PAY ALL FEES ELEVATION MARK CodeAnalyss,Viarnly&La��on map REQUIRED BY THE GOVERNING AGENCIES 3 THE CONTRACTOR SHALL VISIT THE SITE AND VERIFY THAT ALL EXISTING CONDITIONS AGREE WITH INFORMATION SECTION REFERENCE �THESE DRAIMNGS AND +9_��-„ --- A-1 1 F�r��1 THE DESIGN THEY SHOWN ON THE DRAWINGS. ANY CONFLICTS, OMISSIONS OR DISCREPANCIES SHALL BE BROUGHT TO THE REPRESENT REMAIN ATFENTION OF THE ARCHITECT FOR RESOLUTION PRIOR TO COMMENCEMENT OF ANY WORK NO ALLOWANCES WILL P ROJ ECT I N FORM AT ION THE PROPERTY OF 9 A-21 Extenor0eva�ons MICHAELFOLWELLARCHITECTURE SUBSEQUENTLY BE MADE ON HIS BEHALF FOR ANY ADDITIONAL EXPENSES WHICH ARE INCURRED DUE TO INSPECTION DOOR SYMBOL ANDARE INTENDEDTO BE OF EXISTING CONDITIONS a-2•�� USEDFORCONSTRUCTION AD-1 WaII SeC�OC�S AT THE STATED LOCAl10N ROOM NUMBER ANYUNAUTHORIZED 4 PRIOR TO COMMENCING WORK,ORDERING OF MATERIALS AND SHOP FABRICATION OF ANY MATERIALS, THE PROJECT NAME REPRODUCTION OR CONTRACTOR SHALL VERIFY ALL DIMENSIONS AS INDICATED ON THE DRAWING AND SHALL REPORT ANY o�- DooR NuMBER Claggett-Rey Gallery Addition & DRAWINGS OR DESIGN DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION INTERIOR ELEVATION REFERENCE Remodei IS STRICTLY PROHIBITED WINDOW NUMBER 5 DRAWINGS INDICATE LOCATION, DIMENSIQNS, REFERENCES, AND TYPICAL DETAIL FOR CONSTRUCTION 1 STREET ADDRESS MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT NECESSARY FOR PROPER CONSTRUCTION OF ANY PART OF 101 RooM NuMBER 4 2 100 East Meadow Drive THE WORK SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS FOR CONDITIONS NOT WINDOW NUMBER ILLUSTRATED, NOTIFY ARCHITECT FOR CLARIFICATION ANDIOR SIMILAR DETAIL 3 Vait Village Inn A-a.�o Phase #3 6 THE SCOPE�F WORK INCLUDES ALTERATION TO EXISTING FACILITIES WORK WHICH IS REQUIRED TO COMPLY PARTITION/WALL TYPE Unit 607 - WITH THE INTENT OF THE DESIGN SHALL BE PERFORMED TO PROVIDE A COMPLETE AND FINISHED PRODUCT, INCLUDING WORK WHICH MAY NOT BE SPECIFICALLY INCLUDED ON THE CONTRACT DOCUMENTS, AND SHALL BE ^ Vall, Colorado 81657 � INCLUDED IN ALL BIDS CONTRACTOR TO INSPECT AT TIME OF DELIVERY ALL FIXTURES PROVIDED BY OWNER TO t�.J��'" P ROJ ECT D I R ECTO RY INSURE PROPER QUANTITY,THAT ITEMS ARE DEFECT FREE, AND MATCH INVOICE CONTRACTOR TO BE �/ RESPONSIBLE FOR INSTALLATION, WHICH MAY INCLUDE BLOCKING, SHIMING, ETC IT IS THE GENERAL CONTRACTOR'S O RESPONSIBILITY TO COORDINATE ALL ITEMS SUPPLIED BY OWNER'S VENDORS AND TO VERIFY THAT ALL MATERIALS RECEIVED ARE IN ACCORDANCE WITH THE SPECIFICATION HEREIN ANY DAMAGES ITEMS OR DISCREPANCIES BETWEEN OWNER � MATERIALS SPECIFIED AND MATERIALS SHIPPED SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PROMPTLY Claggett-Rey Gallery � 7 THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL INSTALLATIONS, CONDITIONS, 100 East Meadow Drive MATERIALS AND FINISHES WITHIN THE PROPOSED CONSTRUCTION AREA AND ALL ADJOINING PROPERTY AFFECTED Vail Village Inn w � BY CONTRACTOR'S OPERATIONS THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING FOR ALL Phase #3 � � STRUCTURAL REMOVAL TASKS THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR REMOVAL TASKS THE Unit 607 CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY OR DURING THE VaiI,CO � .� EXECUTION OF THE WORK ANY EXISTING MATERIALS AND FINISHES WHICH ARE DAMAGED, SHALL BE REPLACED AS 81657 '— NECESSARY WITH NEW MATCHING MATERIAL AT THE CONTRACTOR'S OWN COST AND EXPENSE ITE � � 970-476-9350 , 8 THE CONTRACTOR SHALL DO ALL CUTTING, CHASING, CORE DRILLING, PATCHING AND REPAIRING AS REQUIRED � 'i � � � TO PERFORM ALL OF THE WORK THAT MAY BE INDICATED ON THE DRAWING, AND ALL OTHER WORK THAT MAY BE � REQUIRED TO COMPLETE THE JOB PATCHING SHALL MATCH ADJACENT SYSTEMS, MATERIALS AND FINISHES ARCHITECT � � M C� UNLESS OTHERWISE NOTED Michael Folwell Architecture 1 �' 9 CONTRACTOR SHALL EMPLOY ADEQUATE NUMBER OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND 731 Cresent Drive w �1 � � � , .� EXPERIENCED IN THE NECESSARY CRAFfS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS Boulder, Colorado 80303 AND THE METHODS NEEDED FOR PROPER PERFORMANCE OF THE WORK ALL WORK SHALL BE PERFORMED BY DULY 720-334-1168 � W � � � . LICENSED TRADESMEN AND AS REQUIRED BY STATE AND LOCAL GOVERNMENTS FOR EACH APPLICABLE TRADE, michael@folwellstudios com J Q � � � (PLUMBING, ELECTRICAL, ETC )WHO SHALL ARRANGE FOR AND OBTAIN REQUIRED INSPECTIONS AND SIGNS OFFS � ^� � Q � � � 10 THESE DRAWINGS ARE DIVIDED INTO SECTIONS FOR CONVENIENCE ONLY CONTRACTOR, SUBCONTRACTORS, �-� � CONTRACTOR 5 VENDORS AND MATERIAL SUPPLIERS SHALL REFER TO ALL RELEVANT SECTIONS IN BIDDING AND PERFORMING THEIR � �'` � ` ,�� WORK AND SHALL BE RESPONSIBLE FOR ALL ASPECTS OF THEIR WORK REGARDLESS OF WHERE THE INFORMATION '' ` " ���' OCCURS ON THE DRAWINGS � � � y G�,�� (f� � U 11 CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE WORK OF ALL TRADES AND SHALL PROVIDE ALL � "f _ ��*�� SCOPE OF WORK � W (� ^ D I M E N S I O N S R E Q U I R E D F O R O T H E R T R A D E S S U B C O N T R A C T O R S S H A L L B E R E S P O N S I B L E F O R C O O R D I N A T I O N O F T H E I R � _ . __- c w � L L.I � — � WORK WITH THE WORK OF OTHERS, AND SHALL VERIFY THAT ANY WORK RELATING TO THEM WHICH MUST BE � -= ��4 �'— PROVIDED BY OTHERS, HAS BEEN COMPLETED AND IS ADEQUATE PRIOR TO COMMENCING THEIR WORK ` - ,,.�,,,.,�„� �� '` °�° Interior alteration to First Floor Retail space no structural � � � � ..--�__.:.:""...._.vmt.»>... � " � �- ��� , '��� - '� changes Q �j 12 CONTRACTOR SHALL PROVIDE STRUCTURAL BACKING/BLOCKING FOR ALL WALL AND CEILING MOUNTED � � , t?�� ` ��,�..�; - _ _ � ,4-�� �?� -- . ��w� , � _ FIXTURES, FINISHES, EQUIPMENT, BATH ACCESSORIES, ETC ��. � � .�r:�''r�.� - , ��� r , � -'""'f� .xr� ��� ."�' a. �"'-�-'"'`^�-`"��'���.-�....._.�.=.-,s�"".��"""�",.�.� �rr�J fa�s�,}�'�'1ri�s � � � � '_ lla�l_ �,�� _ 13 CONTRACTOR SHALL INSTALLALL MATERIALS AND EQUIPMENT AS PER MANUFACTURERS WRITTEN INSTRUCTION r, ¢'- ��� �� �W� �� e �_ � �ates��� � , _ Goif7st C�DE ANALYSIS � � AND/OR RECOMMENDATIONS '�`��;� �,f�a°' .� � - -� � -- - I I ' � 14 CONTRACTOR SHALL AT ALL TIMES DURING THE COURSE OF THE CONTRACT KEEP THE ADJOINING PREMISES , - ,,���" ;� t -� CODE REGULATIONS 2003 IBC W .�:�� � > INCLUDING STREET AND OTHER AREAS ASSIGNED TO OR USED BY THE CONTRACTOR, FREE FROM ACCUMULATIONS OF t ��� � = OCCUPANCY GROUP. Group B WASTE MATERIALS AND RUBBISH CAUSED BY CONTRACTOR'S AND SUBCONTRACTOR'S EMPLOYEES � � ����' µ '; � � 1 5. C O N T R A C T O R S H A L L A S S I S T W I T H D E L I V E R Y A N D S T O R A G E O F O W N E R S U P P L I E D I T E M S, A N D D I S P O S E O F } �'��� ' � �-� � C,� ANY RESULTING TRASH. " ��"� _ � � ' � � �' 16. CONTRACTOR SHALL VERIFY WITH OWNER AND IMPLEMENT ALL LANDLORD CONSTRUCTION AND DESIGN __ ���� �l�st Vai! SQUAR E FOOTAG E J CRITERIA, SHOWN ON THIS SET OF DRAWINGS OR ACKNOWLEDGED IN WRITING � � ,-�'� �� �� y°� U 17 CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR ALL TRADES PRIOR TO INSTALLATION, AND SAMPLES OF � t ��� �� � Existing space to be remodeled 1,276 Sf ALL MATERIAL AND COLOR FINISHES FOR ARCHITECTS APPROVAL CONTRACTOR SHALL PROVIDE TIMELY AND _a COMPLEtE DATA ON ANY DEVIATION/SUBSTITUTION FROM CONTRACT DOCUMENTS , - � � � - � 18. CONTRACTOR SHALL BE RESPONSIBLE FOR A THOROUGH, PROFESSIONAL CLEANING OF THE ENTIRE FACILITY � PRIOR TO OWNER TAKEOVER DATE ALL EXPOSED HORIZONTAL AND VERTICAL SURFACES INCLUDING, BUT NOT LIMITED TO, THE FOLLOWING MUST BE WIPED CLEAN AND FREE OF DUST DATE: 05-10-0� WALLS, EXPOSED STRUCTURAL MEMBERS, STAIRS AND RAILINGS, CABINETRY, LIGHTING FIXTURES/LAMPS, DUCT WORK, SPRINKLER PIPES, STOREFRONT SYSTEMS, INTERIOR/EXTERIOR GLAZING, ETC �a9��M+� DRAWN BY: MF �. ALL FLOORS MUST BE MOPPED CLEAN ---- 19 CONTRACTOR TO PROVIDE THREE(3)COPIES OF AS BUILT INFORMATION, OPERATION AND MAINTENANCE Mid Va�) CHECKED BY: 4 MANUALS, INCLUDING ALL PRODUCT GUARANTIES AND WARRANTIES � REVISIONS: 12-12-06 20 CONTRACTOR IS RESPONSIBLE FOR A CERTIFICATE OF OCCUPANCY PRIOR TO FINAL RETAINAGE INVOICE, ANY AND ALL TRADE TESTING AND SIGNOFFS, AND SHALL VERIFY THAT THEY HAVE BEEN SECURED AS ISSUED BY REQUIRED S ITE LOCAL AUTHORITIES PRIOR TO OWNER OCCUPANCY Vicinity Map north �.� �� ������ ' ���� #.� � ,.�: ��.� ,��������� , � � � � � y�gr�� � �'��?������� ��*����'���"� SITE SURVEY �;���� ��.z� � d �suL��a�?,�,...y,;�..,��...,.� �.��,.',"�3�� "1 �--.....�,�MA 8ep R ���t..�:��������-�I��s�.��'� "�` E�r�.!���:::.e�,.� ❑ "�-�.,..,e,.�Fib,r �w�i���.?i�:�},��s�+���:�'�`�'�3�r:��#���'�t,�C*.����i���s;,t�;'�..E� PRE DESIGN �-..� �d�����'`".`.,,, �'#�@ Cun.^?ru�3.�t t('ii1�'��:3'�:�G�'.+'�3r��'�'�`� �i�1�f�c'"aT1�'Ula�:,i13;:�''� "��.,, ��V�1� 8 '"''re`" '`.�..�„� �}i�`�Gt�fa�`:.'`.^E:a�V3�e�I`3���:�� r�r'�a�'r���4'��.`°�r�3Y�`�����CTf�s.�n :, '' "' �"�'` }����� t}y.`�� �' � SCHEMATIC DESIGN � " �.�.. '� ��z�:W��;c.;�i �,t°Er�,,��,��,sS�+��}�� .et��r;�,,, ��M�r,},,���r'?�u3cy'x�R¢�z;a�.i. a t S� `�� � �IF,���Sw�w�'J:ij C.�ww3 L�`4���'s��alt�i dr��3*��`�r� {KY�SiM'��+��'✓`e`o''�r��d��.s�Qi i.ifv� ��� , �i I r1 '^c'' y'". Nia `w �+fT:.r.Yiw(���� � �`•_•, '',. e ��'"~— � S�;'i��� �h r.,Ju�n .t..t��#���:���i�.�r s�� �'�°� �zv--- ^�..,,, C�R,�, S 1T�a;sr a�gt�S;�3'!d3.,���''�ta�".�a`.si�i'��''i.1,�4t?i�f7�:���::'�tIfl3Grig��L:'.d1��r� �� E`a s' Ray, ° � �"`�^�^��,, d ��ekRd �r�xc:�;,:��fe�r�;,i�:t�:�ca.�.t��`�:���:������n��;�:t'���3�,'�;� �' �,T_- � DESIGNDEVELOPMENT � - . 8 _ �� ����f�4�,:����3��. � �� ; �g ���� _ � ..' "',w,,,��_ r`,Pe�,4 r...- '3 � t'}�rS�t�2�+73:Vf3C3tl�C:R,3('�:�:r�' � � _ V � �'� .,"""'^`^^�.='•�'� ,,, � rr.��Ch::'d;�?":i.MfE,'ti14'iC3� "' �.0 ��"'•' u, i3i�L2�^seti�'�°�"ifS[�vu�`+v.(.w:� �,�,,, �F "i�� ��u��%��`x�� 2 � �� � - � SITE PLAN REVIEW W�BBdp�y�a, �d� �a`w"'w„`' C6d5'�i"&��`�CSU��1:lt,e ��A ^� ^�"2 " ` � �`S F�'•�...,,�.ri � . "�`'w• `�-� � � !` - � s R'it���..�,�'' V-� ��,�„� F� � DOCUM NTTION .. - .�„�...,�.,5� ..�. _ �''-,.�„�'�-��,,, e , . , DamRd '_,',, ��°�•���,�� � SUPP MA.�JO��-�--- ��vet � � � ' ' Etr' I,�,��� t � rL� V� � U il� �s ��� �a �� ,..1NqApy,� � °;°'l� py ..� G ' " fl��;�� ' � � 1� ��, ,pd � t�`'''''��*�. � i} ��Ger�rllR.� � ,- f �� fiq� � �`�--�`'� _ ��,;,,FoiM?erli - " L7 � st i?d � .,. � '`'''°,`""`_--;� :`�._ :,'����._ � �. �` ''� � Rd +,,'<<t u, �,�' ,� �,'���` � ����A''�a, e �� , 5.E ? �°'°F�� ��� "�`'�����` !� �� l �Pa �/f _ �.a�.2�},v���f` i�� �v � 'Ff �� � ��; �..� V/` i� a ��4��{::��.A� �� � �P� ��� � �-���rar (�tc�t�s��` e °�`� .'�:<i,�:,. V r '�'�' � � �Q3 �� -�vi �'r, : � ��,� �i 1 �S�D J�R��� � � 1 Location Map north / - � - � e,- , � �'`� , M ichael Folwell - � ; FINISH SCHEDI�LE DOOR SCHEDULE Architecture ROOM# FLOOR BASE CEILING NORTH WALL SOUTH WALL EAST WALL WEST WALL NOTES ON SPECIAL CONDITIONS DOOR# SIZE DESCRIPTION HARDVIARE NOTES ON SPECIAL CONDlTIONS . 1-100 6'-8"X 6'-0" FRENCH DOORS PASSAG_DEADBOLT CUSTOM 731 CRESCENT DR 100 GALLERY WOOD WOOD GYP BD GYP. BD GYP BD GYP BD BOULDER, CO USA 101 GALLERY WOOD WOOD GYP BD GYP BD GYP BD GYP. BD 2-100 6'-8"X3'-0" EXTERIOR FULL LIGHT LOCKSEr W/PAN►C HARQWARE EXTERIOR FINISH TO MATCH EXlSTING BUIl.D1NG WINDOWS &DOORS $0303 103 GALLERY WOOD WOOD GYP BD GYP BD GYP BD GYP BD 1-107 6'-8"X 3'-0" 1 HR DOOR PASSAG= DEADBOLT phone 720-304-8082 �- 104 OFFICE CARPET VfNYL GYP BD GYP BD GYP BD GYP BD GYP BD fax 303-499-4337 105 COPY AREA CARPET VINYL GYP BD GYP BD GYP. BD GYP BD folwell studios com 106 ART STORAGE CARPET VINYL GYP BD GYP BD GYP BD GYP BD GYP BD 107 ART STORAGE CARPET V1NYL GYP BD GYP BD GYP. BD GYP BD GYP 8D O THESE DRAIMNGS AND THE DESIGN THEY REPRESENT REMAIN THE PROPERTY OF MICHAELFOLWELL ARCHITECTURE WIND4W SCHEDULE ANDAREINTENDEDTOBE USED FOR CONSTRUCTION AT THE STATED LOCATION ANY UNAUTHORIZED WINDOW# SIZE TYPE HARDWARE NOTES ON SPECIAL CONDITIONS REPRODUCTION OR OTHER USE OF THESE DRAVIANGS OR DESIGN 1-104 X 7'-7 1/2" V I F OPERABLE CASEMENT EXTERIOR FINISH TO MATCH EXISTING BUILDING WINDOWS IS STRICTLY PROHIBITED 2-104 X 7'-7 1/2" V t F OPERABLE CASEMENT EXTERIOR FINISH TO MATCH EXISTING BUILDING WINDOWS � O � � I � � I ' I � 28'-2" V.I.F � � 8'-0" 7'-3 1/Z" 5'-4 1/2" 7'-6" � � I CUSTOM WOOD COL UMN > '� I � , ' �- � � �n • � � � � M c� --- - - - - - - - - - � `., T , � . � W J O � �p � � i � � COP > 3 102 ` � i05 ^� � � � (� O EXTERIC�R EXISTING ART STORAGE I COPY � J Q � � '� C�AI l FRY . SPA�E °O . P� ' 104 � � � (� 00 � - O � 5.., � ~ � it - , NO�ONGER A � � � � � � O i 07 �' 11� IL lDING DOQR AT U � BUIL TlN DESK � � �,,, THIS OPENING ,_ „ REPLACE � � � � ( > EXISTING WINDOW v EXIS7ING ART STORAGE m ��O�ERABLE W � � W � �_ STONE HEARTH GAS KlVA FIREPLAC:E „ 1 00 �' CUSTOM BUILTINBOOKSHELVES gp� R 16 -3 1/2 103 0 �+ iO4 � ""; O � > WOOD � COL UMN ��, CUSTJM WOOD COL UMN LLERY� "' �E � T \ � � � / � `� � � �-+ 6',S� 2 REPLACE W � • EXISTING WINDOW > � � 1 �10� 90° R 1�2�, 104 W/OPERABLE �R North-South Buildin Section �,� 6°° R "",TS � 2 �� � �� BUILTINBOOKSHELVES 3�_7�� � Scale: 1 /4 = 1 - 0 � 0 1�, �.�-ERY I z�-71�z� '6�- J �: ; ; v H r' BUIL lN WOOD SHEL VINC > �" 30° R ; m � STONE HEARTH .m � � DATE:S/10/06 _ BUILT lN BOOKSHfLF/PA1NTlNG � DRAWN BY: I -" . DlS'LAY ISLAND � REMOVE CHECKED BY: �� EXISTING GALLERY I '-0 1/ ° EXISTING W oow , ' CUSTOMVi00DCOLUMN &DOORS R PLACE REVISIONS: 12/12/06 W/WALL TO ATCH "' EXISTING Sl lNG �b BUIL T�IN SHEL VING � CARPET WOOD __ _ _ , y� � in I � � 1-100 �• � CUSTOM WOOD COLlNIN � � � m � _ I ,�" � N � i N ' ; � SITE SURVEY I � � � �, � m � j�t�y � � PRE DESIGN � � � BUILTIN SHEL VING `-' t° �` � I � �� � � SCHEMATIC DESIGN �t � , � BUILT lN SHELVlNG � 3. � � DESIGN DEVELOPMENT sr, �g,, ` GAS KNA FIREPLACE �e� 11'-11" � 6`-6 1/2" � � _� � SITE PLAN REVIEW � � 30° R � 30° R �� �� � CONSTRUCTION � < DOCUMENT REMOVE � 3'-11" SUPPLEMENTAL EXISTING WINDOW 11,_6 � �2�� INFORMATION REPLACE W/WALL TO MATCH - EXISTINGWINDOW EX1STlNGENTRYDOOR EXISTINGSIDING (�� GO�� � REPLACE EXISTING DOOR W/ EXTERIOR 2 �' � FULL-LITEDOOR W/PANIC HARDWARE _1 �,�- - {,)�, � 28'-2" V.I.F. �� U �- ` VI/ALL TYPES � � ��3 �� - 3 5/8" METAL STUD WALL WITH 5/8" GYP, BD. �S� Z i�����' . � � - EX/STING WALL Floor Plan ' 1 ' Scale: 1/4" = 1 '- 0" PROJECT NORTH : M ichael Folwell � : Arch itectu re , 731 CRESCENT DR BUILT IN WOOD SHELVING BOULDER, CO USA � 80303 � STONE HEARTH phone 720-304-8082 fax 303-499-4337 folwell studios com BUiLT lN BOOKSHELFlPAINTING DISPLAY ISLAND �� REMOVE �THESE DRAIMNGS AND � EXISTING GALLERY �� EXISTING WIN�OW THE DESIGN THEY CUSTOM WOOD COLUMN u &DDORS REfLACE REPRESENTREMAIN " W/WALL TO MaTCH THE PROPERTY OF �� EXISTING SlD1�JG AND ARE NT NDE TO gE ECTURE ,i USED FOR CONSTRUCTION BUILTtNSHELVING ATTHE STATEDLOCAIION CARPET WOOD �____ ANY UNAUTHORIZED i ' REPRODUCTION OR � ' OTHER USE OF THESE i ` i DRAIMNGS OR DESIGN � i IS STRICTLY PROHIBITED CUSTOM WOOD COL UMN � � � ,- � . � , , � , � , � �-=== �� - �� �� �� � �� �� �� OBUILT lN SHELVING � GAS KIVA FIREPLACE � O � � � O � Z � }+ _ � � � . �- ._ � � � REMOVE � REPLACE WINDOW � - � M C� W/WALL TD MATCH � � � � � 3 EXISTING WINDOW EXISTING ENTRY DOOR EXISTING SlDlNG REPLACE EXISTlNG DDOR W/ EXTERIOR J w � � O FULL-LITE DOOR W/PANlC HARDWARE � Q � � � QD � � � � � � o � � � o �- W � — C.� W � w � � — � �._ � � o � c� N O - � � � � � T � .� W � C� � C� Q J U � DATE: 12/13/06 � DRAWN BY:CG CHECKED BY: " REVISIONS: ' � ; � SITE SURVEY ' � PRE DESIGN MEN'S RESTROOM WOMEN'S RESTROOM � SCHEMATIC DESIGN � DESIGN DEVELOPMENT � SITE PLAN REVIEW � CONSTRUCTION DOCUMENT � SUPPLEMENTAL INFORMATION Site Plan Site Plan ' . � Scale: 1 /4" = 1 '- " 0 PROJECT NORTH Michael Folwell Architecture � 731 CRESCENT DR. BOULDER, CO USA 80303 phone 720-304-8082 fax� 303-499-4337 folwell studios com � �THESE DRAWINGSAND THE DESIGN THEY REPRESENT REMAIN THE PROPERTY OF MICHAELFOLWELL ARCHITECTURE AND ARE INTENDED TO BE USED FOR CONSTRUCTION ATTHE STATED LOCATION ANY UNAUTHORIZED EXISTING PAINTEDWOOD REPRODUCTION OR EXISTING BALCONYRAILING SlDING OTHER USE OF THESE DRAWINGS OR DESIGN IS STRICTLY PROHIBITED EXISTING PAINTED WOOD SIDING - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - EXISTING WHITE STUCCO EXTERIOR � O � � � EXISTING EXTERIOR LIGHTING � O � � Z � �= EXISTINGAWNINGWITH - - - - - - - - - - - - - - - - � � NEW FABRIC COVER � � TO MATCH EXISTING CLAGGETT REY EXISTING EXTERIOR LIGHTING � •i � � AWNINGS � Q � � ��� T W � � N00 NEW OPERABLE WINDOWS � FRAME COLOR TO MATCH EXISTINa EXISTING STONE PLANTER BUILDING WINDOW AND DOOR � � � (� O FRAME COLOR � Q � � � Q � �- o _ C� � � — . � � � o >— W c� — v w � W � � �= � PAINTED WOOD SlDING TO MATCH EXISTING EXISTING PAINTED WOOD SlDING � O (� � � 1 — � � T East Elevation ~ �s � „ , �, w > Scale: 1/4 = 1 - 0 (!� EXISTING PAIhTED WOOD SlDING � OUTLINE OF EXISTING CONNECTING BRIDGE — � J U DATE: 5/24/06 EXISTING DOWNSPOUT . DRAWN BY: CHECKED BY: � REUt ONS:, ,r' � EXISTING BALCONY RAILING '������-~ -�. �r�� � �Q' p.� .:; � U� r � ���� � , EXISTING PAINTED WOOD SlDING C� �� �L, �{(� Y EXISTING WHITE STUCCO EXTERIOR (��I� � PRE DESIGN EXISTING WHITE STUCCO EXTERIOR 1 r P 1:D��� � , � SCHEMATIC DESIGN ' J�� � ����:� �• EXISTING BALCONYRAILING �� ��f iq� \" ��` 1�" `�ly�`�,U►k�0 � �J � ` �l. � L, DESIGN DEVELOPMENT � � ; �'� �:o��� r� � � � r� pro -` � � Q SITE PLAN REVIEW ��.�►�. � � � `�Q� $ 1 , � D�CUME TTION - - -- - - -- - - - - - - - - --- - - - - -- - - - - - - - - -- - - - -- � - - - - - - - - - - - - - --- - - - - - - - - - - - - - - -- - - - - - - - - - - - - _ _ � ETI_R€ :, - - - - - - -- - --- �� x_ _ _- ____ _ ' SUPPLEMENTAL �- - - - - - - - - - - - - - --- --- - - - - / - - - - - - - - - - - :,:= =_- _=;_;_ - - -- - - - - - INFORMATION - - - _ - - ' = - �. EXISTING EXTERIOR LIGHTING EXISTING STONE PLANTER EXISTING AWNING WITH ' NEW FABRIC COVER TO MATCH EXISTING CLAGGETT REY AWNINGS EXISTING STONE PLANTER Exte r i o r , Elevations EXISTING EXTERIOR LIGHTING PAINTED WOOD SIDING TO MATCH EXISTING So u t h E I evat io n EXISTING AWNING NEW FULL LlGHT EXIT DOOR W/PANIC HARDWARE � 2 ' Scale: 1 /4" = 1 '- 0" -,�- -- - J � //'�� V� �� ��� ��� �� S �� _� G;,� � GU�,�r.,�S � "Q 'Q '� Q c -;z v � c, :s 'Q "�c- d � Q � 'h "a ';Q, '� "}a '�' '� '�e Q' Q Q '� "�z '� '� '� '� d 'ad=�d-'e'd 'e'd 'ad �d '�d �d 'ad `dd-`�d 'Rd 'Rd �d-'dd `g4-'�d-'gd Rd-�gd=�a '4td ad_Rd Ra Ra 4rd_'ga �d '�a Rd=aa � "¢ c 'v :z '� '� 'Q ;a ;Q -�z, -`a '� "Q '� �, '� Q '� � Q- Q 'Q �¢ Q � � � c '� � '� Q '� Q-'a•'d a•`d 'gG '�d 'Q•`d 'Ftd `R�4 ac ad `Rd 'dd 'F�d 'R�`Q 'Q•`d 'ad ��Q `F�d `ad 'a`d"ad `�d 'Ftd 'F�d 'ad 'ad '�4 4td=ad `e�d_'o4 Rd 'Fd 'F�' '�'s c, Q, � �, '�, � Q � '� '� '�-. ';z "� �`a, ;a "� ;a -� '�• 'ti � '�; '� '�, �, �, c '�,_ c� '�r, '� -� `4:Rd_ a4 Rd �4 ad �d �4--F'•`d F•`d g 4�'d=ad F4��d `Rd e�d=4�d F•'d FG �G �4 F2'd aC a•`d 'ad od_ad g4_Rd g4 R4 Rtd � � R'd� '¢etd � d-'�' a d F � '�'d� R - a`d� �d- ¢`d�' R'd ' d Q �� `��� T.—;--r. � EX/STING CONC FLODR &PAN 5/8"TYPEX GYP BD , f tiIETAL U BRACKET SPACED C�24"O C i 549 DEEP X 3 y25 BY 155-217 INCH , (No 25 carbon sheet steel gaye)HAT SHAPED EXISTING STEEL BEAM FURlNG CHANNELS Q 12"O C WITH NO 6 WALL80ARD SCREWS @ 8"O C WOOD TRIM ,° E�� � -.� � '._ � ■ ■ ■ �t 1r1�Y. � ' tt ^t Ce�ling Section @ Secondary � .�_ - .--,;�> - � �q q # � A t° 4�! y Interior Steel Beam 'oist °�� ��-.. `�. � �y ��f��{� � 1 k �-' ' � .'"- k`;�' A° , Scale: 1 1 /2�� _ 1 �_ ��� �-,,�ry},'v�.r��'�i�,s�>� � _ , - _� _ - ; � _ �...,, . ,--: �� .,.� — __ s.- _ . -�,� �,�,�y,;�� ,��, � �s.;,rs;��.� FIRE-RE5t5TANCE-RaTE�CONSTRUCTiQlJ ?� �y�,�,,� ��-a�y t � r;�, ��,�i - "�L5 v'�1'°�'i41.,h-e:( r F s.,-� y.�� � A�'_.L�-Y.V � TABL�720.t(3) � -�y,=��`;� � , _ P,tt�JiG7UT�1 PRdTECT{OrJ FOR FLOCR AfdD ROdF SYSTEP.7Szo �-� ���,��{;�?�F ��- _,- --- _ __ ,F,� �g�; THICKNE55 OF FLOQR 6SINIlAUL1 THiCRP�E55 �`�r� � OR ROOF Sl.AB I OF CEIUNG ��� +���,r;��;': mehes a�"r ° �_�__ 1 (Incn� ����,�Z,[�� FLODR Oq ROdP RE[d � 4 � 3 2 � i 4 ( 3 � 2 � 1 ;�� ,��;�k�-�;�:w€ corisraucnora _4 J NU�dBER _ _CE1L1:�G COPt57RUCT[ON hour�hoar�hour Qrot�t I haur,haur h�Uf h0u� "" ''`�''F�I�`=;�' c� ua ' f ` +��' y�� ] Sili o -- -- - ° � • i �"� ,���U�r=; i.egzreLal�cnner�lr �"� � I 7 U !b' S U 3.5�— -- ,f -. � _ I :? ��',,��`°'- ,,-�-,�- tt��„° �Sl.�b(n�ceilu��r:c�uired)-Atin�me�m ccr��r m�er � I -- �^—T�--"`f F� '�'+�,-�,'_`f,� � C:L�?U[1.11L• i �N, �,�,�,4,y���r ae�re_m�ru�crcic �V�-I i nannrc�treaed rr�n}curcment d�sll ocrt t+�tcse th��r� fi 6 5.7 !d G� 3? ' a K. � ` �/"h '_" { '� � t — '^y. ,��`:�"` �z 5ar�d-li�:hntct�4t cc�n..ntc 3-I I ' �(� � � '� ����` `s ° $.1 .. K ! .�,�� ,�°n 3 ' 4 Li h�we��E� r e a-I t � � , _. =�` ���_, { � 1 u nCrc[ _ - - --- • --- 5 t �-E-i 3.h � �a — , _ ! _ ���:`°�. � - -_ -- '�.�'� 't,;`�:`�:= � Slab��uh iusp�nd.f�CClLC6�UC 1 C1'Ci11GilI11C^1'_ �iCl:ll� ; �T� F�' �;���{:� 5-1.1 ;l+lastu o�er mnt.d l.�th:�nach.d w`!,"col,i•eolled � ,� ' , �y ���'�'"'�`` �»� �.,- �rhanrtcls ti�ac�d I?"nn ccnter CeiGne Tuc.ucd G" ' - — — t �- — — �g 'w�L: i ;nk�nimum hctma�u«c, , � �r�?� ',��'-�':�;: ���.,_ j � /"T} r?� p;vm n alflu��irc � �,�'� ����r�•:�;�,V 1 ,s p =7 1`attac6ed[o f101 S � � � ' ;� ,s��,a��,.,, i '�����.� � ��ndi(No 2S c..ubon shect,lr:l�aesl b}'f3"�r:p b�, � � ; f °�,� �f��;�•�� � '2� � ` � i I ?°., �;��,�F,_.. IK"hat-fili.epcd g.11�.11tllCd ti1LCI 1I11iifIC�S l�]Lsl • � .�:+kf5-n`_a.. � I"-long N� G r:�rru s Thc rF�.�it�teE�arc spaced?�3" I } I ' �''�` �"�`�;' ( � I ; ^�T _<����- i �ufl rcnter sp.�i 3j"artd arc�a��ror�cd?.IUII�11F,CIf �`��_ "�- > I � � - �"'�r�'_`�'r`.�. I i I � � �x_, � r�_. i.RrmEnrced t�ngth�t:�5"in�zn.�1a b}�D U33 t`u 31 gahanize:( i � " � - '��;;.,o-,�. � 5�1CC1 C.��C �° i � �._.-r"4`Y � "7r."=° �onuclC i j a(t.uuiLCl stccl tT�t strag�hangct5 „�� , '�''-`,,_'`.-�s�?j;� lt:��ing forrned e�f�e�Ifuu cn�a,e thc 6�ti uf thc , f �&:� k"�--�'� ' ' � j -,:�; �;i��=-F- � i � 5•�l ch�iinri.Thr strap le�n,en,rrr,s�weheJ ao[hc S�dc ; — � — i 34`. _ _ , _ `/% _ °�:� ����`''�, � i =� �,�;,.r�., �ot tl�r umcretc ta�sGS u nh'/y_"by 1�/t"lan�z � i ' J' ,����� i , � ��-���,,s � 1 pn�eerKln4cn fasten.n Thc tiv:ilihosr�it inet,�llrcl i � � �"'�'� �,�, - �f' . ' t� , ,�{i�=�-,, i«ith th:inne dtmcncine��ter��ertd�cUl.v lo the � � i �;• ������; � i� �,r'"a�_,� I � chann�lc All cr�d��mts c,c�ur nn ch:�nnrls and ' l i :�, {���;,y,- � `�uPPlemenriry�h,inncls are crosali�d�+,uviQcl to tlie ; � �,�' °'��,�`+i.;' �.ii� _s,�.d,�"�;�,�, i ' � ma=n channele.E?"�ach tide.�t en�E�cymt � , � � ;;�' ���;."- , I '� N`e�ry�'�� uccurrcnccc.7'I�e fniahcd�ceding t�k,c.itrd � '1y-�,�t�_��y„^,- - _ _ aPProCiittalefY 1?"f,4lativ tf�e cof7 ii of ihe llcx,r d�h + � x.:��.t•.. �� ;,.���,�;,fi,, �!G}�ptiuni pl.ielcr on met�l l.�di altachcd to the huttum� - -- ` � i „"�;, ''��ry�.�T�t�, ;cucd u�nli ti�q�lc No 1(i�age uv dvuhlcd Nn 1 S � I , � ��;�. ,�;;�'�,�. (w 1 I I ga�e a�ire ua,�paccd G°on cantcr Pt:ister mned 1 2 i �+ ,� ' , � s ''--''�,FG�: ��`�k;;.., � i far scrat�h�n,�t,I ±Cor hro��n c��,�t.b}•u�cieht. � — .� "l, _1�`� � — /� /K � � ,y'�.�'��';,�`= Ti`rs�i"r' tsx'.a: I � `�3Rsum•to-�an�t.�ewn�atcl'or:-hc�urti}+tc:�t For � ; � � ;,�, �'�;;�r�, � ?.hour st�stecn p[.�ater e.arat � ; � '��� ,:��t=,��'` ` ` - - , - - i t a t;�+��;;;�', �Vcmi�tulE�r gepu�rn pin,FCr on ra��t.J lath an�et�eJ�n � � ' � �: �'��',�?`--�_•� k � _ ! _ _ � _ , _ �t ����s�,.,. !�?.( the h�uom�litrttl��itli su.�lt Nu 16 g,i,s�or�Ir�uftic�l i `�K .���} ��'"'� , ., � �- hx,� I U 11�9-m�h f N��. I 3 f31L'.�_i��}ti��n p�ti 6"tsn ccntcr i I I , `• i ,'°`� °,��' �'a. F4`���..-�-A,':,. _t,'r .`,�_ `a��e. � [emcni 1a+[cr o+�er m�1.i1 l.uh�stnched Itr thc � � � � � -;:� �r�y�y;�'; I � R I , I7t1l�VfT1 4�lOfil Uf JI'ittil5 ttlQl SI(7�IC NO 1!��•�gc ur � ' ;;� , ��' �doubkYlO 439"�l�o l S[���'.gazc)u�rr uer tipac�d ! i •�t ' ,`�,°'_ 6.Stecl�on�s eomttvcted n�tit �'�'� �G°an crntrr Plaster m�red! ?►arr scratclt��ut.I l i — � — � — '' `lyr ;�� ����'.�;'_ �for Uirntn�nat for 1-hour sttite�n.trvd E 1 for ct�tch' I � — — , y��- �.i p��ured rcentur��d con�rete � ! � � _�^,� -r�.��, ��6�b cm mctnf lath furms or � coa[.I.! I.I�v br�lsn ro.tt Por_hour sysEcm h} � i ;� '>r��'��;�_ y11.C��UC711 lttllLCd r _ 1CCIC�If Cl'Rl�ttl In ti.11l(� � i I ' � � ��, �`s`y���_- � � 1 ` - -- - �Ce�Gn::al`/�"T}�pa\�,.,Ilboar.l`.ttt�ct�ed u�'/" `� -�;� �?�T-= . x i r�Y,���__;. ce�a h}3`/w"by O.U?1 an�h((Vu 25 rarhnn,Qirrt i � u`� ,��-'r,�,- �s •cl;n�r1 h.it•sh��:d lurnne 4hanncic 12"«n t � I �.� '��;�w�t — I — ';� �'���.s�; 6-�,i ,c nter w tth 1"lon�ihu G w.rlElxam{scrcw�;�t ti"un � — i — '�/,` _ `�,� _ �sr �x�; F.Wt�, � � cntcr.Ch.mnrls w�ec ticJ tn tx��tum churci at ao�tit, � , I � � °�� . „����; ,++ith dnul�tcit 0.t1»?inch f No IR Et�l',��acc?�t irc or ; i i , ``` �`^��`=' .� '�`° I � 1 S�,E•�yi , - 4+u+�n�ed I�luu�yjcrttils on�vire It.�n�er�r ._ I � I ��� - '���;;," �1°�xxt-f1nn:J�}�ptiurn pl.ititrr mixcJ 1 1 bg�tu�cht i ( I —'--_. ""'�� � ;a� ,�,�, I , � i � _� ,�.�rx , es�pc�m tn,,ind.e_,�r��ate.wPPf�cd over neetal].idi. � =�, . ryn;•, iTnih � trJ.l �th treJ C�"un�rncer to`!j �I��nncls spsC��t E i�l." � '� ,��"-.� 1 M,..,_ ��1,, _ _ �r � _ �ry;; �r�., , on�tia[er.t'h.�nnch�c:�reJ tu Ju«ts:�t cach — ` ' -; — I ' ��' :�k;�:=�.�: � ;,: r����-�; �ntcrsection«�th ttvo titr.utde uf tl 019�nclt(\u 1 d � , �� �'�`�,��`„- Ix.-�..,. x��wC:,:�_ - -- �13 11�.gsge'F•,�Iv.u�vcd«irc � k�� 6��;��,r � N; �_;.z fC��ITIf littc/jl 3,r,3'.�`i":', ''y,e= F'.�lsn„�,. ji�L� 3�-h�`'���, t28 �'° =�"'" 2006INTEANA710NAL BUILDING COOE'�';�{ ;�;��5�,- 21 ,�. -y u,--�� ��k},n���,�;�.. ��3 .n �,_:. SECQND LAYER 112"PROPRIETAR Y G YPSUM C�YPSUM BOARS APP/ED TD FLANGES AND M i c h a e I F o I w e I I EX/ST/NG PLASTER WALt WALL BOARD APPL/ED TO SUDS WITH 1518 ,�iCROSS WEB OPEN/NGS FASTENED TO STEEL SECOND LAYER 1/2"PROPR/ETARYGYPSUM TYPE S DRYWALL SCREWS f2 O C CREATING S�TUDS WITH 1"TYPE S DRYWAL�SCREWS WALL BOARD APPLIED TO SUDS WlTH 15/8" Arch itectu re A STUD CAVITY BETWEEN BASE AND SECOND C�24"D C TYPE S DRYWALL SCREWS 12"O C CREATING - BASE LAYER 7/2"PROPRlETARY TYPE X LAYERS OVE COLUMN FLANGES A STUD CAVITY BETWEEN BASE AND SECOND GYPSUM BOARS APPLIED TO FLANGES AND I LAYERS OVE COLUMN FLANGES ACROSS WEB OPENINGS FASTENED TO STEEL � STUDS WITH 1"TYPESDRYWALL SCREWS FACELAYER 1/2"PROPRIETARYGYPSUM WALLBOARD STEEL CO�UMN BASELAYER 1!2"PROPRIETARYTYPEX 731 CRESCENT DR. C}24"O C APPLIED TO STUDS WITH 2 1I4"TYPE S DRYWALL SCREWS GYPSUM BOARS APPUED TD FLANGES AND -� BO U LD E R, CO USA >2"O C 1 1/4"BEAD APP�IED WITH 4D DRYWALL NAILS ACROSS WEB OPENINGS FASTENED TO STEEL JO/NT COMPOUND 1l16"THICK APPLIED OVER CORNER STUDS W1TH 1"TYPE S ORYWALL SCREWS 80303 15/8"NON COMBUST1BtE STEEL STUDS BEAD AND FACE LAYER @ 24"O C phone 720-334-1168 � fax 303-625-1030 �, EXISTING BATT INSULATIDN EXISTING BATi'INSULATION michael @folwellstudios com EXISTING PIASTER WALL 5/8"TYPE X GYPSUM BOARD 1 5/8 NON COMBUSTIBLE STEEL STUDS � 0 THESE DRAWINGS AND , THE DESIGN THEY REPRESENT REMAIN THE PROPERTY OF MICHAELFOLWELL ARCHITECTURE FACE LAYER 1/2"PROPRIETARYGYPSUM WALLBOARD AND ARE INTENDED TO BE APPLIED TO STUDS W1TH 2 1/4"TYPE S ORYWALL SCREWS USED FOR CONSTRUCTION 12"D C 1 1/4"BEAD APPLIED WITH 4D DRYWALL NAILS ANY UNAU HORIZEDATION 15/8"NON COMBUSTlBiE STEEL STUDS JOINT COMPOUND 1/16"TH/CKAPPLIED OVER CORNER OTHER USE OF THESE 7 5/8"NON COMBUSTIBLE STEEL BEAD AND FACE LAYER DRAWINGS OR DESIGN EXISTING STEEL COLUMN EXISTING STEEL COLUMN STUDS EXISTINC STEEL COLUMN IS STRICTLY PROHIBITED BATT/NSULAT/ON EXlST/NG E TERIOR WALL ASSEMBtY EX1STlNG EXTERIOR WALL ASSEMBLY EXIST/NG EXTERIOR WALL ASSEMBL Y � EXISTING PLASTER WALL 5/8"TYPE X CYPSUM BOARD 5/8"TYPE X u YPSUM BOARD EATT INSULATION Column Detail @ Column Detail @ � Southwest Corner Southeast Corner Column Detail @ Interior Wall Column Detail @ East Wall � 5 „ , „ 6 „ , „ 7 „ , „ 8 „ , „ - Scale: 1 1 /2 = 1 - 0 Scale: 1 1/2 = 1 - 0 Scale: 1 1/2 = 1 - 0 Scale: 1 1/2 = 1 - 0 � 3 HOUR FIRE RATING 3 HOUR FIFiE RATING 3 HOUR FIRE RATING 3 HOUR FI4E RATING W (� � � � � C��� � ,�,�� STRUCTURAL � Q� � �� ��'v BEAM � > � . . . , . �� / . �/�/ "s� �— � �' //�� ' ad a4 Rd Rd ad Ra Ra Rd ad Ra �4 ad Ra Rd �a . �(/�� Rd Ra Rd R'a ad `ad Rd ad ad ad `e'd 'Rd Rd Rd Rd �/�� ac� .d Rd aa gd e�a Ra Ra ad Qa a'4 'aa Rd `e`d • � � � � � � � � � � � � � � � � � � � � � � L"' uJ tit tit � R �� R� � Q i Q� Q Q Q L R R i Q� h� Q. Q R 'R tt �� �� �,2 Q � �� �� Q ;z. 1 c' c, c, tz �x. � a s •z •x' Q ie 'c Q � �= � Rd aa aa R4 Ra Ra Rd ad ad e�d ad e�d Rd �d Ra� C �d Rd Rd Rd gd Rd Rd ad ad Rd Ra Rd Rd Rd e'd � V 4 Rd ad �d �d Rd �d Rd Rd �d Ra od a4 � rrl C [2 � Q i � R R Q tt� FL �R� R R Q t[� � Q �� Q� Q i iR. 5R i R �� �� �� Q R Q Q Q tt Ft rz Q� � R� t2�� �� �� Q� Q � _ ' _ ' ' ' ' _ ' ' _ ' � ��% v�d ad v ad ad ad v-d ad ad v�d v�d v�d ad ad cd RG Rd R a4 F°d Rd Rd ad a4 ad ad Rd gd Rd Rd .d ad ad aG �4 a4 d Rd R4 a'd a4 od Fd �R Q � tt � �� Q� Q�i � Q�i tt 4 Q Q Q tt i Q Q R R rt �� �� � Q 'Q `Q � �L� Q C� �� Q� R L [t. R s R Q� Q Q � � R Q R RQ R Rd ad RQ Rd d R d R RQ R Rd Rd Rd gd d '/� d ad R Rd Rd R Rd RQ � \ � W 5 N 00 y Q Q} • Q � � tiL� �t� � Q R �Q R Y YS [i� �2 Lt i � .� � ' ' W O cr� � UL APPROVED 1 RMES NT J .� � Q � FOR 2 UR ROOF ASSEMB Y ' � % � � Q I WOOD 'IRiM UL AP CENT PA/NT , � � � EXlSTING eONC F�OOR I EXISTING CONC F�OOR FOR 2 R ROOF � Y � � O � � � &PAN ' � � � O 2 LAYERS OF 5/8"TYPE X 2 LAYERS OF 5/8"TYPE X — � � � — —� � — � � � CYPSUM BOARD GYPSUM BOARD EXISTWG CONC FLOOR&PAN � � Q I 2iAYERSOFS/8"TYPEX I � W (� � METAL U BRACKET SPACE� METAL U BRACKET SPACED GYPSUM BOARD Q24"OC � Q24"OC � � � � � � w � W � � EXISTING STEEt BEAM I EX/STING STEEL BEAM METAL L-SHAPED BRACKET SPACED Q 24"O C � , � O (� � ' EXISTING STEEL BEAM � O � � I T \ � / � � PRIMARY � EXISTING PLASTER CEILING � p NON-COMBUSTIBLE METAL STUD CHANNE� / -� / BEAM TURAt �� EX1ST NG LASTER CEIL/NG W \ WOOD TRIM WOOD TRIM I r� � , 2 LAYERS OF 5/8"TYPE X GYPSUM BOARD 4 � V NON-COMBUSTIBLE METAL q p.i • STUDS � 8 � � NON-COMBUSTIBLE � p. i�Q D- , METAL STUD CHANNEL 5/8"TYPEX GYPSUM BOARD GALLEf3Y , � NON-COMBUSTlBLE METAL EXJSTING NON-COMBUSTIBLE METAL STUDS PRIMARY � STUDS WOOD TRIM STRUC BEAM � � ` - - � ` v - - ---- - - - - - - - - , 5/8"TYPE X GYPSUM BOARD � DOOR UNIT BY OWNER NON-COMBUST/BLE METAL STUDS @ �6"D C �` � � � � / � / E Tl SEC D UC ME E�����8'� EXISTING EXTERIOR WALL ASSEMBLY P L/STED R ES T % EXISTING GALLERY � � DATE: 11/21/06 � � . � DRAWN BY: �, � 5/8"TYPE X GYPSUM BOARD � � � � � � � � � � - CHECKED BY: i ' BATT/NSULATION � REVISIONS: 12/12/06 1 � a 3 � 0 4 . . . 2 . � . � AD-� � A -1 � t — — — — — — — — — -- — � � SITE SURVEY � � � i PRIMARY ❑ STRUCTURAL PRE DESIGN i EX/ST/NG EXTER/OR WALL ASSEMBLY BEAM , � � SCHEMATIC DESIGN BATT INSULATION PRiMARY � � � _ .. ��.� _ � — — i STRUCTURAL BEAM � DESIGN DEVELOPMENT i I � Q 6 � p_ � p_ � SITE PLAN REVIEW � � r "" � ' � / � CONSTRUCTION � } NON-COMBUSTIBLE WQOD BASE � � � � � � DOCUMENT � META!STUD CHANNEL ) , � � � ,� / SUPPLEMENTAL WOOD BA5E WOOD BASE DOOR UNIT BYOWNER �' '� � �' --• � ❑ INF ATION � WOOD FLOOR 2 SFRUCTURAL ��4� C�L�� � AD-1 BEAM � C• � v� t�� �, � g � r � � 1/2"PL YWOOD SUBFLOOR 1/2"PL YWOOD SUBFLCDR 1/2"PL YWOOD SUBFLODR �. L EX1STlNG CONC FLOOR EXISTING CONC FLO'JR EXISTING CONC FLOOR R e f I e cte d S t r u ct u ra I C e i I i n P I a n ������ � 1 Wall Section @ Primary Wall Section @ Primary Scale: 1 /4�� - 1 �- o�� � I nterior Beam I nterior Beam Exterior Wal I Section PROJECTNORTH - 4 „ , ,� 3 „ , „ 2 „ ,_ „ Scale: 1 1 /2 = 1 - 0 Scale: 1 1 /2 = 1 - 0 Scale: 1 1/2 = 1 0 0 N NATI�RAL OUTDOaR AIR VE�TILQTIO� IViECHANIC�4L SPECIFICI�TiON: MECHANICAL LEGEND ARENOTNECESSARILYU DONLEGEND � , ROOM SI7F ���� - ROOM (SQ.FT.) VENT1LA710N 1 GENERAL oA OUTDOORAIR � MANUAL BALANCING DAMPER '}'� -�p V 4% OF SQ.FT. a FURNISH ALL LABOR,SUPERVISION, MATERIALS, EQUIPM N�CAND FACILITIES � � RA RETURN AIR CHANGE OF ELEVATION N L r . 100, 1(l2& 103 Galle 836.5 33.5 NECESSARY TO FURNISH, FABRICATE, DELIVER,STCRE AND INSTALLALLWORK gq SUPPLYAIR —�° (D)DROP (R)RISE � � O N ry NOTED ON THE DRAWINGS AND/OR SPECIFIED HEREN '�'' p � 104� 105 O�ice 182.2 7.3 b THE CON7RACTOR SHALL FURNI5H AND INSTALL ALL WORK NECESSARY TO MAKE A � EXHAUSTAIR FLEXIBLE WCT CONNEC710N � � V o0 COMPLETE SYSTEM WHETHER OR NOT SUCH DETAIIS ARE MENTIONED IN THESE � RETURNAIR DAMPER � �NING VMfES IN 90°e�ow � %j � C� 106 St��rage 59.9 2.4 SPECIFICATIOPJS OR SHOWN ON THE PLANS, BUT WI-ICH ARE OBVIOUSLY sAO SUPPLYAIRDAMPER � � p � DUCT S I Z ES A R E N E T F R E E A R E A � Q �j � NECESSARY TO MAKE A COMPLE7E SYSTEM, EXCEP'lNG ONLY THOSE PORTIONS SG SUPPLY GRILLE � C� � O g THAT ARE SPECIFICALLY MENTIONED HEREIN OR PL�INLY MARKED ON THE � 1ST NO IS SIZE OF SURFACE SHOWN 1 Q7 St��ra e 66.1 2.G RG RETURN GRILLE 2ND NO IS DUCT dEPTH U �N t� ~ ACCOMPANYING DRAWINGS AS BEING INSTALLEQ UWDER ANOTHER SECTION OF THE TG TRANSFERGRILLE � � � � � SECTION THRU SUPPLY AlR DUCT � ❑ O �.- SPECIFICATIONS � SD SUPPLYDIFFUSER � ��N N � U TOTAL� 1144.7 4S.S RD RETURN DIFFUSER SECTiON THRU RETURN/EXHAUSTAIR DUCT � � � �� 2 WORKMANSHIP �L- +� 4-- �*-' � � ( � � � a.7HE WORK SHALL BE ACCOMPLISHED IN A THOROUGH AND WORKMAN-LIKE MANNER To TRANSFER DIFFUSER Qx SUPPLTY DUCT 7URN DOWN � � � � �t'(S SATISFACTORY TO AND MEETING THE APPROVAL OFTHE�WNER AND ARCHITECT OO THERMOSTAT � J p., �O � AI� B�L���E � RETURIVlEXHAUSTOUGTTURNDOWN � .� (\j `N U QD DUCT AIR SENSOR �S 3_ MATERIALS ���$� SUPPLY REGISTER/�FFUSERlLOWER � � � � OPERABLE NECKSIZEv •� ((f '� � � � a ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND THE BES7 OF THEIR SQ DUCTSMOKE DETECTOR � � UNIT TAG Sen1ice Q11(. WINDOW SQ/FT. RESPECTIVE KIND,FREE FROM ALL DEFECTS AND OF THE MAKE AND QUALITY �E����� RETURN REGISTER/DIFFUSER/LOWER � •L N '�1"' W � � W H SPECIFIED � F1RE/SMOKE DAMPER NECK SIZEt-/ OUTSIDE AIR REGISTER/DiFFUSERtLOWER — � Q = � 1 0 4&1 0 5 O F F I C E � F I R E D A M P E R ��-E EXHAUST REGISTER/DIFFUSERlLOUVER W � � WINDOW#1 106&107 STORAGE 2 20 54 15 4 SITE INSPECTION NECK Size� � �� � a CONTRACTOR SHALL VISIT THE SITE OF WORK PRIOQ TO SUBMISSION OF HIS BID M❑ MOYOR OPERATED DAMPER(MOD) � U � O C 104&105 OFFICE AND THOROUGHLY FAMILIARIZE HIMSELF WfTH THE IVORKING CONDITION3&EXACT ��—CFM DOOR UNDERCUT WINDOW#2 2 20 54 �rj POINT OF NEW CONNECTION V 1 0 6&1 0 7 S T O R A G E NAT URE OF THE WORK �'— 'C W 00 O b SUBMISSION OF A BID ACKNOWLEDGES FULL RESPCNSIBILITY FOR FURNISHING A g.,.,_�� (A)SEC710N CUT LJNE N R'f J O = ' � {B)SHEET SHOWN ON ;� .� � �' WiNDOW#t3 100,102&103 GALLERY 2 20 54 15 COMPLETE AND FUNCTIONAL SYSTEM V N c NO CHANGES IN CONTRACT WILL BE MADE TO ACCa1lIMODATE OR ALLOW EXTRA -� N � � FUNDS FOR ANY OMISSION WHfCH RESULTS FROM AFAILURE TO THOROUGHLY L � d- � WINDOW�4 FRONTDOOR 1 12 24 2 MAKE THE EXAMINATION � � TOTALS� 47 5_ CODES AND PERMITS � m a ALL MECHANICAL EQUIPMENT, INSTALLATION,ETC,SHALL CONFORM TO THE 2003 O IMC AND ORDINANCES AS INTERPRETED BY THE 70tVN OF VAIL BUILDING � DEPARTMENT. G E��E�A L N�TES. b CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERVIITS AND INSPECTIONS C COPIES OF ALL PERMITS AND INSPECTION REPORTSSHALL BE SUBMITTED TO THE ARCHITECT 1 ELE�CTRIC BASEBOARD UNITS EB�-1 THR ESB 2 PROVIDED BY �'�� R�G�ST ELEi:.TRICAL CONTRACTOR. SHOWN HERE FOR REFERENCE 6 AS-BUILTS ^0 O H ,1, ONLY. a.CONTRACTOR SHALL PROVIDE A COMPLETE SET OFAS-BUILTS DOCUMENTS WITH �� " = O ALL CHANGES NOTED THEREON AT THE COMPLETIOJ OF THE PROJECT AND Pf�IOR + 2g 4 , � * f TO FINAL ACCEPTANCE AND PAYMENT ��s�� ���m�� 7 GUARANTEE '� �� a CONTRACTOR SHALL UNCONDITIONALLY GUARANT�ALL LABOR AND MATERIALS ON �SS�ONA�E�G � ALL WORK AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER COMPLETION 8 SUBMITTALS a_CATALOG INFORMATION AND CUTS OF ALL EQUIPMEV7 AND DEVICES SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW(SIX CCPIES OF EACH) 9 COORDINATION � a THE DRAWINGS ARE DIAGRAMMATIC AND INTENDEDTO SHOW SCOPE � b THE CONTRACTOR SHALL COORDINATE HIS WORK VI1TH OTHER TRADES TO PROVIDE BEST ARRANGEMENT OF AL�DUCTS,PIPES,CONDUf,ETC � a � 10 CUTTING AND PATCHING s� � � a ALL CUTTING AND PATCHING REQUIRED OF THE STRJCTURE(NEW OR EXISTING} � Q SHALL BE PROVIDED UNDER OTHER SECTIONS OF THE WORK �— C b PROVIDE NECESSARY REQUIREMENTS TO 7HE PRO.ECT SUPERINTENDENT � � � , B °'� �—+ 2 ► 6 c X-RAY SLA85 PRIOR TU CORING � � EXISTING ART STOftAGE %�� T 105 � co�v B 11 CLEANUP � SPACE p a UPON COMPL.E710N OF THE WORK UNDER THIS SEC-lON,THE CONTRACTOR SHALL � O REMOVE ALL SURPLUS MATERIALS, EQUIPMENT ANC DEBRIS INCIDENTALTO THIS Q .. 4� WORK AND LEAVE THE PREMISES CLEAN AND ORDERLY (Y'� ! �_ ��� g 12. TEMPERATURE CONTROL DEVICES � � � � ART STOR GE 2 a THE HVAC SYSTEM SHALL BE PROVIDED WITH AN AI.TOMATIC SPACE TEMPERATURE � 2, ,��TO EBB-1 CONTROL DEVICE THAT SHALL BE CAPABLE OF BEIN3 SET TO MAINTAIN SPACE i � TEMPERATURE SET POINTS FROM 55°F TO 85°F � b CONTROLS SHALL BE ADJUSTED TO PROVIDE A TEM�ERATURE RANGE OF AT LEAST � � � 5°F AND UP TO 10°F,AND HAVE A CAPABILITY OF TEFMINATING ALL HEATING AT A Q� � iO3 a��oC� TEMPERATURE OF NO MORE THAN 70°F I � � GALLERY c THERMOSTATS SMALL HAVE NUMERIC SET POINTS Itl°F,ADJUSTABLE SETPOINT � � ^� STOPS AND SHALL BE MOUNTED AT 54"ABOVE FINIS-IED FLOOR ADJACENT TO THE W ROOM'S LIGHT SWITCH � ■� °� � 13 BEFORE STARTING ANY WORK,THE CONTRACTOR FOP THIS SECTION OF THE WORK � � SHALL EXAMINE A COMPLETE SET OF DRAWINGS FOR ALL.TRADES, INCLUDING � � '�' ARCHITECTURAL,STRUCTURAL, HVAC,ELECTRICAL,FRE PROTECTION AND PLUMBING � > y 4' DIMENSIONS,SPACE REQUIREMENTS AND POINTS OF CONNECTION TO ALL EQUIPMENT � � � SHALL BE VERIFIED,AND ANY MINOR ADJUSTMENTS NECESSARY TO AVOID CONFLICT "�'�et J J � WITH THE BUILDING STRUCTURE AND THE WORK OF THE OTHER TRADES SHALL BE � `V G�,L��Q� MADE CONTRACTOR SHALL NOTIFY ARCHITECT IMMECIATELY IF ANY MAJOR � Y CONFLICTS OCCUR � 14 COORDINATE LOCATIONS OF ALL ROOF AND EXTERIOF WALL OPENINGS WITH ALL � RELEVANT TRADES,AND PROVIDE WATERTIGHT FLASFINGS WHEREVER � , s I m�o PENETRATIC�IVS OCCUR EXACT LOCATIONS AND 51ZESMAY BE DEPENDENT UPON �� EQUIPMENT SELECTIONS,CUORDINATE SIZES AND LOCATIONS OF ALL OPENINGS WITH APPROPRIATE EQUIPMENT REQUIREMENTS ,ir\ 15 PERMANENT ACCESS TO E4UIPMENT SHALL BE PROVDED,AND A MINIMUM OF 30" i ' CLEAR WORKING SPACE IN FRONT OF ACCESS PANELS TO THE COMPRESSOR, � BLOWER ASSEMBLY AND AIR FILTER SECTION OF THE EQUIPMENT SHALL BE PROVIDED (� BY GENERAL CONTRACTOR AEC PROJECT#: 26752 �XlSTlNG GALL�RY Y / '16 ALL EQUIPMENT SHALL BE SECURELY FASTENED TO TNE BUILDING STRUCTURE WITH Y CODE APPROVED VIBRATION ISOLATORS DATE: ISSUE� EBB-1 O $� 17 EACH PIECE OF EQUIPMENT AND ALL SYSTEMS SHALLBE ADJUSTED AND RE-ADJUSTED 11-3-06 CDS TO INSURE PROPER FUNCT(ON OF ALL CONTROLS, MANTENANCE OF TEMPERATURE, ADEQUACY OF FLOWS AND CAPACITIES, ELIMINATION OF NOISE AND VIBRATION,AND SHALL BE LEFT IN PROPER OPERATING C�NDITION 18 THE GENERAL CONTRACTOR SHALL FURNISH&INSTALL AL�OF THE REQUIRED ACCESS PANELS IN THE DRYWALL CEILINGS TO GAIN�ERVICE ACCESS TO THE O EQUIPMENT. � 19 ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO fHE MANUFACTURE'S ' / 3�2 INSTALLATION OPERATION&MAINTENANCE MANUALS�ECOMMENDATIONS Drawn By_ Chedced By GALLERY ESPEClALLY FOR SERVICE CLEARANCES RJB RPC . / � � � 20 ELECTRICAL CONNECTIONS a UNLESS OTHERWISE INDICA7ED ALL MAGNETIC MOTJR STARTERS,THERMAL �.�+11.1C1�1�1�I 1�.�L ~� OVERLOADS, LOW VOLTAGE THERMOSTATS, CONTRJL RELAYS,CONTROL � TRANSFORMERS AND SOLINOID VALVES SHALL 8Y FURNISHED BY THE MECHANICAL CONTRACTOR VEl�TTILATION b PROVIDE MOTORS AND EQUIPMENT FOR ONLY THO�E CURRENT CMARACTERISTICS � INDICATED ON THE DRAWINGS. c_ IT IS THE INTENT OF TH(S DIVISION TO REQUIRE A CCMPLETE SYSTEM PER THE �T /, AT � CONTRACT DOCUMENTS LI"11 V $, � d COORDINATE ALL EQUIPMENT REQUIRING ELECTRICAL POWER,REGARDLESS OF C VOLTAGE,WITH OTHER TRADES,SO THAT ALL SYSTEMS ARE COMPLETE AND _ OPERATIONAL , e ALL THREE PHASE MOTORS SHALL BE PROVIDED WI'H PHASE LOSS PROTECTION SCALE• 1/4"=1�-O�� ' f ALL SINGLE AND THREE PHASE MOTORS,STARTERSAND DISCONNECTS PROVIDED ' , NORTH BY MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR ���������� ���� 21 TEMPORARY HEATING DURING CONSTRUCTfON a M�CHANICAL EQUIPMENT SHALL NOT BE UTILIZED FOR TEMPORARY HEATING. b GAS FIRED TEMPORARY HEAT SHALL BE PROVIDED BY THE GENERAL CONTRACTOR. O SCALE 1/4"=1'0" 1 of 1 o����,��,�����r�. -_ 1�- _ -�__-__------ �-r�..�..�,�.� 0 N CO '����,��'��� ����i���,��'��� PARTITION SURFACES --� , � • TYPICAL 8'0' CEILING � � - CUT INSULATION FLUSH ' ������'��� � °'��, � � � � �� ������I ������������ WITH PART�TION � � FIRESTOP MADE IN ` � � C� �N,� 1 YVO SECTIONS O RECESSEDORSURFACEDOWNLICaHT ABBREVIATpNS Q 20 GA GALVANIZED � �� 0p � PIPE SLEEVE CUT 1=LUSH a WALLMOUNTEDUdiTFlXTURE AC -ABOVECOUMER SCOPE Furnish all materials and labor requir�d to execute this work STEEL FIRESTOP- WITH OUTSIDE PAFtTiT10N AFF -ABOVEFNISHEDF100R (/) N V U o0 RECESSEDFl.UOR IIGHTFUOURE as indicated on drawing and as specified,as necessary to complete the EACH SIDE OF Ae AFG -ABOVEFlNISHEDGRADE � (n � �� SURFACES AL -AWMINUM contract Electncal work shall inciude, but not lim�ted to,these ma�or PARTITION,SCREW pa SURFACEFlLOR LIGHTFDCIURE q) -COPPER � C � > �; items TO PARTITION 1� MAIN CIRCUIT BREAKER FIXTUREOESPGNATIONS o�s� -n�s�cw�no�, � p INSU�TIOI'� UPPERCASE-FIX7URETYPE EM -EMERGENCY GC � &B R A N C H C I R C U I T B R E A K E R S LOWERCASE-SNA7CHOESIGNAYION EMP -ENERGYMANAGEMENTPANEL U •� RS �1 SHAOING ON PIXTURE HJDICATES EMERG BATTERY BACI(UP EWC 'ELECTRIC WATER COOLER Q� � �v/ A Compiete wmng system for new lighting and power as shown, � � n MAXIMUM MOUNTING HEIGHT IS GND -GROUN� � � T � including new panelboards new cor�duits newvinres,new`nnnng - �� �� �� FWORESCENTSTRIPFURURE GFl -GROVNDFAUlTN1TERRUPIER � � � � c�sy��, �^��':�s�'"�`3x� _-. �.�k�,'�=��,; � ����;,�;� ����„<.�d,��w � ���i 48 , MINIMUM 1518 NF -NOTFUSED ��tn N X devices, new con tro l dev�ces,e tc for a com le te I� h tin an d �.�� �--���� �#����-�` t? `����5������:���,������� F,�`i4��, �3 T� T R A C K L I G H T A S N O T E U O R S C H E D U L E D N I C -N O T M C O N T R A C T � � N � t 1� (� P 9 9 u .,x �� . and ower s tem �� � � WALLNBlSMER NTS -N T o� �s. :...� � ++ V--- P � � �'C�X � p T o—Q POLEPAOUNiED FDQURE UG -UNDERGRWND n' � O � /� y+� POST(80LLARD)FlXTURE � -��T��PROOF W � L �y a Complete feeder(s)installation as reqwred for new and/or "� _ � � �O l..l XflNR -7RANSFORMER n' a �y, O > electrical a aratus as shown on sin/�le Ime dia/��am 3nd ` -*- at�,._�„up+_�--.r,,,.,-�, 7M`%��� , \���`� � �p V�T �78' -MOUNTNOHEIGHTTOCENTERWE �+ �J � PP `J u� yM1{;KAru.T..�,"�,.ys,r+0.?+,+.-iY"v'¢'F.ycf.1 3cP�g'`,aY jv" "y. sv��w�.,,e- ,�� _\ �i 4y4��' � y��;x`fhe �z 3'�7" 'km�:c "�;`� e� +`�=w-�* '' s�;:_,-- ;�.� .-. � CEILINGORVIEALLMWMEDEXITl1GliT OFDEVICEAFFORAFG � � N � I1 dra�nnngs wf'�'�,' �•?�=`•��• ^*•�:����`� i��x':'�".�.�i��a;`a..'X,�' i'?�:'�;:���`u-��s`"�z'r�,,�G4�-�'�="'A.`��``;��?; h'v X 0 � EMERGENCYBA7TERY4IGHTS FIREALARMSYSTEM � x_., �,: � ,,,,, � 0� � b Com lete branch arcuit winn re wred forthe connection of � � , � � DUPLIXRECEFTACLE�18"UNLESSNOTED �F�� FIREAURMCONTROLPANEI .� V �^' CO ap � P 9 q � �.�, � OWBLEWPLEXRECEPTACLE�18'UNIESSNOTED � fIREALARMANNUNCIATORPANEL . �/ � emergency i�ghting and exit signs to existing emergency stand FIRESTOP SHALL_ v� � p fWSHhtOORDUPLEXRECEPTACLE L L �' SEAL ENDS OF � fIREALARMPULLSTAiION W � U r 1 by power system FIT TIGHT AROUND � v � $PECIAIOUTtETASNOTED INSULATION WITH QJ AIARMHORNORSPEAKER PIPE 2' MIN (TYP) (V � DUPLERRECEPTACLEHALFSIMffCHED�18'UNLESSNOtED �" N � � O V A P O R B A R R I E R � J N� p� COMBHJATIONHORNfSTROBEORSPEAKERlSTROBE � Q � I` � TELEPOWERPOLE �H TiERMALHEATDETECTOR W � C� 2 Compiete prov�s�on, installation and connection of lighting fixtures, COATING VAPOR BARRIER � � MULTI-OUTLETPLUGSTRIP exit signs and lamps as specified and as shown on dra�nnngs NOTE •� SMOlCFJ10NIZATION bETECTOR L' -� /1� COATING v Q Q Qi JUNCTION 80X C1 FIOOR,CEILNG OR M WALL �p pHOTOELECTRIC SMOKE DElECTOR � (� Q !'� �y 3 F�re alarm system wdl be by others Coordinate connections to the COVER FIRESTOP WITH T1N0 COATS � m ♦ COMPUTERREIFPHONE WTLEf INFLOORORV�LL ,,,�, HEATlPHOTOEIECTRICSMOI�OE�ECTOR '�' U W O C OF WHITE VAPOR BARRIER COATING �- FINISHED FLOOR � TELEllI510NOU71ET �� o�oro�o-roR V �C � � hood&duct detection W � TELEPHONEBACKBOARD � � (� 0 � CONWRRUNCONCEALEDINWALLORA80VECEILWG SPRBJKLERSYSTEMFLOWSMTCH }+ � J � Q 4 Complete connection of HVAC/Plumbmg motor(s),water heater(s), �- SPR9JI(LERSY5TEMTAMAERSV�fCH _ � eqwpment, etc.fumish by mechanicai-refer to both electncal and �� � � � ' I —� CIRiXJRHOMEE2UN p� S.ra�BE S � ��Y1 � ����� ��'�� ������� ��'���� — CONDURRUNBELOWFLOORORGRADE SMOKFJFIREOAMPERCONNECTION (1 W � and mechanical drawmg for scope and work and addiUnal�nfor- � CONWRS'Rl&UP-CAP&MARK � REMOTEPlDICATORLIGNT � mation $ LIGHTSVIATCHAT48'UNLESSNOTED �"' cO NO SCALE suescwars SECURffYSYSiEM Q X s=z-PO�esw,rai NOTES 3=3-WAYSVNTCH � CONTACTDOORSWITCHMJAMBORHNGE O 5 Provide grounding and bonding Facil�ties <=+wn,rswr5p+ 1 HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF 80X K=KEY-0PERATEDSIMTCH � "�10N"�10N�"S�'��"' m UNLESS NOTED OTHERWISE T0=7HERMALOVERLOADSWTTGi ��R � 6 Complete all electncal demolition as required P-S�CH�TMP�� ❑K KEY-0PERATEOACCESS5IMTCH � � � �� '�� � DIMMERSMiCHWJVWTTAGE ��( SURVERUINCECAMERA 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN Q PUSHHUTTONCON7ROLSTATION 7_ Core drdling and patching of exist�ng bwlding structure reqwred for � TOP OF DOOR TRIM AND CEILiNG LINE � PNOTOELECTR�CELL DIS7RBUT10NEQUIPMENTSYM80LS electncal work Core dnil�ng shall foilow Bwiding Standard procedures T�e�a+ �—�- DISCONNECTSWITCH and contractor shail have wntten approvais from bwlding owner pnor 3 MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATI�NS Q 111ERMOSTATAT6Q'UNlESSNOTED ---,r— �SES ��Q RE�� PROJECT.CLAGGETTARTGALLERY i i � � PROJECT# 26752 `� DNISqN15EQUIPMENT CIRCURBREAKER � O � ST to start of any work. , AND NOTED ON ELECTRICAL FLOOR PtANS SHALL GOVERN Q FOODSERVICEEQUIPMENT �� CURRENTTRIWSFORMER ,a CLIENT CLAGGETT , ENGINEER �SOH OVER THOSE SHOWN ABOVE �N TRANSfORMER O� ' �' 8 Test of entire system and work ' ' ' � ' ' ; CO1N"A'"��`nON��" � MEfER � �o DESCRIPTION PANEL A NEW PANEL ELECTRICAL LOADS � ! VOLTAGE 1202�8V,3P.4W Q(3}� SPEAKER IN CERNGORVLLALL � �pp�E7�CMp7tpR 5fARTER � • "' 2� [�O� �7 ,r ti MOUNTMG.SURFACE�--��--~- i MAINS I 150A MLO 4 FOR CEILING HEIGHTS HIGHER THAN 7�", WSTALL FIRE ALARM V�{ VOLUMECONTROLAT60'UNLESSNOTED DISCONNECTSWffCH t-- 9 Operating, Mamtenance and identfication instructions manuals,if , O� ,, � r an TYPE EXISTING ± i i AIC I 10K NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80'AFF � �, MICROPHONEOURETINROORBOXORNfALL �� P�B���R������H���� ,p s �� � y PHASE PHASE OTHERWISE INSTALL AT 6"BELOW CEILING C CALI-IN SiMidi `�,,O �� a � �.����o�g,��� . ,� �,w DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION � PROGRAMBELL m TRANSFORMER �,�SS� G� • 10 PERMITS AND FEES: Obtain and pay for all necessary perm�ts,mspea 0 ��R� ��p GROUND UNAL�N tions, examinations and fees or charges necessary for execution and 5 MOUNTING HEIGHTS PER IBC 2003 AND ADA CODES � ���K RECEPTACLES 5 900 ?0 1 1 2 1 20 1800 TRACKLIGHTS A qMPUFlER � CIRCUffBREAKER complet►on of electnca{work. ❑ � MOTOROVTLET COPlER 180 ?Q 1 3 4 1 20 1050 TRACK LIGHTS RECEPTACLES 4 720 :0 1 5 6 1 20 1050 TRACKLIGHTS � AUTOMATICTRANSFERSIMTCli 11. REGULATIONS AND CODES. RECEPTACLES 5 900 20 1 7 8 1 20 1800 TRACK LIGHTS A Appl�cabie codes� National Electnc Code(1999) RECEPTACLES 5 900 ±0 1 9 10 1 20 1800 TRACK LIGHTS Conform to the prevading edition and amendments thereto ofthe BASEBOARD HEATING 1414 30 2 11 12 1 20 100 SHELVING LIGHTS Town of Vad Electncal Code, pertinent NFPA publicat�ons � 1414 13 14 1 20 1800 TRACK LIGHTS � - and to the reqwrements of Federaf, State or otherCity agenc�es SPACE 0 15 16 1 20 1250 OFFICE LtGHTS having�ur�sd�ction SPACE 0 17 18 2 30 1063 BASEBOARD HEATING 12 CONDUIT AND WIRE SPACE 0 19 20 1063 " � � ; � � SPACE 0 21 22 2 30 850 BASEBOARD HEATiNG PANEL � A CONDUCTOR SIZES AND TYPES_ Use only copper�nnre,600 voit „ A ° �' SPACE 0 23 24 85D B B B � msulat�on,stranded in sizes#8 and larger,solid in s�zes#10 and SPACE o 25 26 o SPACE REWORK B � A � � smaller Contro)wmng shall be#14,stranded In s¢es#1 and SPAGE 0 27 28 0 SPACE � 3 � T 105 B � � O smailer, use types TW,THHN orTHW in s�zes largerthan#1,use ExIST►NG ART sTORAGE SPACE 0 29 30 0 SPACE ��i'+' �r THW or XHHW. Use type THHN for w�res entenng or passmg 0 31 32 0 107 SPACE 2 �_ � � through fluorescent hght�ng foctures 0 33 34 0 ART STORAGE � A� �, � � B MC cabie permitted per local codes o 35 36 0 '� 0 37 38 0 - C B B 3 g � � � 13 ELECTRICAL DEVICES 0 39 40 0 B � � A Convenience receptacles wdl be 20 amp,commerc�al grade o 41 42 o A- 3 �` � � decora style_ F�nish per owner or arch�tect e � � LOAD CALCULA710N SUMIlAARY J RE1Nl7RK EXfS11NC PANEL,PRdVIDE NEW CIRCUIT BI�EAKERS AS REQUIRED � EXISTIrdG ART STORAGE ---- � 104 � � � � B Light switches wd)be 20 amp, commeraal grade, i REFERENCE EXIS'1NG PANEL SCHEDULE FOR EXISI"ING LOAD CALCULATION I � � � � B J A_7 OFFICE � ^, decora style Firnsh per owner or archdect. CAICUlATED POVUER FACTOR PER EXISTfNG ANC NEW LOAD CALCULATIONS WE HAVE A NET REDUCTION OF � � � y Q 95 ' EIEGTRICAL LOACS OF I 11227 WATTS , � 1� g C Dimming switches will be a m�rnmum of 600w or as noted CONNECTED LOAD ! CONN�TED AMPS � � DEMAND LOAD DEMAND AMPS A-22,24 ��� � � `V Provide decora style,fin�sh per owner or architect LI�HTWG ! 10650, � 31� 1 ; ; 13313� ; 39 GALLERY � � D All mounting heights�nnN conform to ADA guidelines Typ�cal receptacle RECEPTACLES 3600 1D� ; 360o I 10 A � , � � heights wdl be+18"AFF and swrtch heights�nnll be+46"AFF MECHANICAI. ; 6653 8 22i ! I 7361 2aI � A-16 � unless noted otherwise. KffCHEN I o, ! O1 ; ; 01 i o � B �s TOTAL I 209041 ( f 63i I 24274� i 73� � E Provide GFI type�eceptacles at kitchens,bathrooms, � � � � � ( f � i ,� A-4,6 � � � � garages, exterior etc as requ►red by code � � A 2 g B A-18,20 � � �m8 � 14 SUPPORT . q A D � � � � � A S u p p o r t a i l e l e c t n c a l e q w p m e n t i n d e p e n d e n t o f a c c e s s i b l e c e d�n g s a s � � � �� �� �� a � � � ••— requ�red by NEC_ � � � �` 15 ELECTRICAL BOXES � � � �� A At fire rated wali s ace electncal boxes at o osrte sides of the wall PROJECT_CLAGGETTART GALLERY ' I PROJECT# 126752 � •— � no less than 2�F"horizontal distance pP CLIENT:CLAGGETT i I �_�EN�lNEER i SOH � �m � i �.�, A-14 � � � � B When phone,TV&power receptaCles are sf�own on pian next to each other DESCRIPTION PANEL A OLD PANEL ELECTRICAL LOAQS ! ! I �VOLTAGE '1201208V�3P,4W � Locate respective receptacles next to each other on site with no more MOUNTAVG SURFACE ��! �( � (—j(�—! �rMAiNS 150A MLO than 1"seperat�ng cover plates TYPE EXISTIN� —� � ��AIC ��K � , DESCRIPTION A B�SE C 3KR P CIR CIR P BKR A B�SE C DESCRIPTION ���`����`� ������� GALLERY � - M � � � FC COfVTROL 100 ?0 1 1 2 1 20 1500 UGHTS �� � FAN COIL 2500 30 2 3 4 1 20 1500 LIGHTS 2500 5 6 2 30 2500 FAN COIL itn FAN COIL 25Q0 30 2 7 8 2500 " A-8,10 " 2500 9 10 2 30 2500 FAN COtL f� � ` B RECEPTACLES 540 ?0 1 11 12 2500 '�/ � FAN COIL 2500 30 2 13 14 1 20 540 RECEPTACLES A-1 AEC PROJECT#' 26752 " 2500 15 16 1 20 540 RECEPTACLES � RECEPTACLES 540 >_0 1 17 18 1 20 540 RECEPTACLES RECEPTACLES 540 _>D 1 19 20 1 20 54o RECEPTACLES REFERENCE THIS PLAN FOR POWER PLANNING ONLY. RECEPTACLES 540 20 1 21 22 1 20 540 RECEPTACLES REFERENCE ARCHITECTURAL PLANS FOR LIGHTING, DATE: ISSUE: a 23 2a � 2o sao RECEPTACLES RECEPTACLES AND SYSTEMS � 0 25 zs o 11-3-06 CDS 0 27 28 0 A-9 0 29 30 0 � 0 31 32 0 0 33 34 0 F 0 35 36 0 '�~ 0 37 38 0 f� `'� � 0 39 40 0 � 0 41 42 0 • LOAD CALCULATION SUMMARY � 102 Drawn Bp Checked By 1 � ( 1_____ _ � I � GAL�.ERY SOH AEC ' EXIS7ING PANEL�ECTRICAL LOADS FOR DOCUMEIYTATION ONLYREFERENCE j �,,, CALCULATED POWER FAGTQR PANEL A NEW FOP PANEL SCHEDULE AND ELECTRI�CAL LOAD CALCULATIONS_ i 088 1 1 J � ' � CONNECTED LOAD 1 CONNECTED AMPS DE:MAND LOAD DEMAND AMPS f � ELECTI�I�AL LIGHTING 3000� i 9; �_� 3750� � 11; / A-11,13 RECEPTACLES 5500 15i ' S500 � 15� � MECHANICAL 25000 i 81� �( 26250 86� ' e (�NE-LI�eTE KITCHEN I o1 I o� I , I oI i o� �} � �� TOTAL 33500! � I 1051 �— i 35500 � 1i2i i I i I I I I I ( I i �� ( MECHANICAL EQUIPMENT SCHEDULE f � ' S�HEDUL�S TAG DESCRIPTION HP/KW/F�A VOLTAGE PHASE CONDUCTORS SWffCH CIRCUff BREAKER REMARKS , HARDWIRE PROVIDE OIL-FfLLED BASEBOARD , BB ELECTRIC BASEBOARD PROVIDED 250W/LF 208 1 (3#1d,1#10G)12"c CONNECTION 30A2P LENGTHS AS SHOWN = BY ELECTRiCAN VIA T-STAT BERKO LF SERIES OR EQUAL NORTH . ERV-1 ENERGY RECOVERYVENTILATOR 3 5 FLA 208 1 (3#12,#12G 12"C 302 20A2P � �� ���� DH-1 DUCT HEATER#1 �KW 208 3 (4#12,#12G)1�2"C 3013 20A3P SCALE 1/4"=1'0" •