Loading...
HomeMy WebLinkAboutVail Lionshead Filing 3 Block 1 Lot 1 (4).PDF � � � � �0 � � , � � ' � � � .- � I � �� ` -; 1 � r � � - � o�� l � �1 JJ '1 � � ...�J J_I ��I ..s J �.J J � a � O ° ' o , a � a ' a .; �� � � � � ' 1 � � � � � . � � o .� � � � I � r1 ; r > > ; 1 � � I � �� -� � 1 � f � _ � _ c _ � � � � �.� �� � ...�� ..�� ��� �� ...� � � � J � o J � , Q � I � � \ � O � � � - � � ` � � ' �� �' � t'' o y � � � o � �..s�l�1�I/ �...� �I �I �..aJ �J 3 ° � � , _ o � i 3 � � � y L H � � 3 O � � �JII�� � �� �--� _� � �� � r � � I�� i-�� �--� � � _� � �--�� �--�TJ� ♦r , � `Y� � T-�� �-�� ►� / � -i T--� _ �� � 1 � 1 � r 1 'ti' � �-�, I , r 1 ,1 S � � 1 ' � � � � J �IJ �I� J�I�I �� = 9 N vi �J J � J._I J � J J J _I _�_I J_I J .J J J .�J J� -..1 J J J J J�J J a a� �. � c � v a y � H L � � � e d N ° v r Q r � O CONTRACTOR: . � ~ . MONITORING CENTER. ALARM SERVICE COMPANY: U APEX �ECURITY GR4UP I- 1429 GRAND AVENUE, SUITE D ��� �o ��� GLENWOOD SPRINGS, COLORADO 81601 BASSETf tAPE� ��' �o a�N 1429 G RAN D AVEN lJ E ~ TE�. (970) 945-2152 FAX (970) 945-7922 SUIT D , 1429 Grand Avenue, Suite D � °go =z ��� GLENWOOD SPRINGS, COLQRADQ 81601 - o �NU �� W4� S EC U R ITY G Rt�V P Glenwood Spr�ngs, co 8 � so � Z o�� g �z� .. � J ��� �� ��� a+ E-� w z ; U L# 970.949.6677 Q/�/ ��� z€� ��m � W � LL } Z W2J WF � j ° �_ O U Z ��W �"'� ��NZ r�, ?� W/I� 3QKS 1�U1 �Q�Q ✓ry�' /y� V "�� ZN Ua�y M'�"� W PROJECT ANALYSIS BATTERY CALCULATIONS GENERAL NQTES N�W ��� N�� W W �`�� m� � 3��i �Zi.�i ��� � � � � , �ati F4 TOTAL TOTAL �, All requ�rements of contract spec�f�cations and draw�ngs apply ' N � a � 0. � QUANTITY STANDBY STANDBY ALARM ALARM � A � A � D EVI C E CURRENT CURRENT CURRENf �iOd� �1�a�yS1� €AMPS� €AMPS� €AMPS� €AMPS� 2 Installation shall conform to all requirements of applicable electncal codes - N FI R E P R 0 TE C TI 0 N C 0 D E S Occupancy: B 3. Wiring methods and materials shall conform with all applicable sections of NEC Article 760. � Number of Stories 2 FX-2017-12A 1 0.230000 0 230000 0.380000 0.38000C � � ' 4. See Mircom Field Wiring Specifications for additional installation requirements. � �. O 4 ALL WORK SHALL CONFORM TO THE CURRENT EDITIONS OF NATIONAL, Tenant Area C200 DM-1008A 2 0.080000 0 160000 0.100000 0.20000Q o o ' „�� � � STATE AND LOCAL CODES, AND OTHER REGULATING AGENCIES WHICH DACT/UDACT-100 1 0.045000 0 045000 0.120000 0.12000G ' �o� � p HAVE AUTHORITY OVER ANY PORTIONS OF THE WORK. ALL CONTRACTORS 5. 120VAC 60 Hz input power for fire alarm controls shall be a ded�cated, lock�ng, properly labeled, o o x � �� �k AND SUBCONTRACTORS PERFORMING GENERAL CONSTRUCTION, MIX 2251/A 1 1 0.000230 0 002530 0 00650Q 0 07150C source � o � �� .. MECHANICAL, ELECTRICAL, PLUMBING OR RELATED WORK SHALL COMPLY MIX 5251 RP 7 0.000200 0 001400 0 007000 0 04900G �� � � �1 � � _ � WITH APPLICABLE SECTIONS OF THE CODES THAT HAVE JURISDICTION 6 All wiring, including shields, must be dry and free of shorts and grounds 3 �„ CLASS STYLE MIX-M500MA/MB 18 0 000400 0 007200 0.005500 0.09900( � �� �� ` � z CIRCUIT CLASS STYLE DESCRIPTION MIX-M500R A 3 0.000300 0 000900 0.005100 0.01530( � a° � �� (� � � � � 7 Provide M�rcom with one copy of "as built" draw�ngs so accurate documentation can be maintamed. a y �� _. Z A P P L I C A B L E C O D E S: I.D.C. B B INITIATION DEVICE CIRCUIT 4-WIRE SMOKES 40 0.000070 0 002800 0.051000 2.04000( �; o^ � ;� � O z o� � , � � � � S.L.C. B Y SIGNALING LINE CIRCUIT SIGNAL LOAD 20 0.000000 0 000000 0.060000 1.20000( $ 120VAC is not permitted in same conduit with low voltage wiring. N C �� .�- � W � � � r 1997 UBC UNIFORM BUILDING CODE N.A.C. B 4 N O T I F I C A T I O N A P P L I C A N C E C I R C U I T � ~ � � •� � � 9. Do not apply power except in the presence of a factory-tra�ned Mircom. technical representat�ve. I�1� = R a 1997 UFC UNIFORM FIRE CODE * MIX-2251/A 5 0 000230 0 001 150 0 006500 0.03250( � W * MIX-5551A/RA 6 0 000200 0 001200 0.007000 0.04200(� 10. Any smoke detector head �nstalled before bu�lding is cleaned and accepted shall be cavered to � � � � 1999 NEC NATIONAL ELECTRICAL CODE protect from dust Any false alarms due to d�rt-contaminated heads shall be the respons�b�l�ty � � TYPE OF SYSTEM * MIX-M500SA/MB 3 0.000400 0 001200 0.005500 0.01650(� of the electrical contractor � � 1999 NFPA 72 FIRE ALARM CODE ZONE PROTECTED PREMISES * S2415 2 0.000000 0 000000 0.061000 0.12200G �� � 11 There will be no condu�t entry allowed 18" or lower on the side panels or through the bottom �- '�� � . ADDRESSABLE DEVICES * S2430 1 0.000000 0 000000 0.084000 0.08400G of all control equ�pment backboxes. � ,`` Town of Vail Code Amendments 0 . . * P2475 3 0 000000 0 OOOOOd 0.172000 0.51600(� � * PC2475 2 0.000000 0 000000 0.188000 � 37600G 12 Manual pull stat�ons shall be mounted at 48" above f�nished floor to the top of dev�ce � � � TOTAL 0 454 5 364 �3. Locai f�re Quthority shall witness final test. SYMBt�LS LIST SEQUENCE OF OPERATION DERATINGOF20% 0091 �.0�3 SHEET INDEX W � HOURS QF SUPERVISION X 60 32 688 OUTPUT MINUTES OF ALARM X 0 167 1.075 � � � a EDWARDS NO EXCEPTION TAKEN F�MAKE CORRECTIONS NOTED �� O SYMBOL DESCRIPTION • • a CATALOG # 0 REJECTED .,�f""t REUISE AND RESUBMIT � � � 1 O MIN = .1 67 HOURS [�SUBiJIIT Sr ECfFiED ITEM a � J J FA0.00 COVER SHEET p FACP FX-2a17-12A FIRE ALARM CONTROL PANEL a -� ¢ o MINIMUM BATTERY SIZE REQURIED 33 763 AMPHOURS � � � � Z z w O � '- FA1.00 PANEL PLAN VOLTAGE DROP CHECKING !S DNLY FOR GENERAL CONFORMANCE WITH TNE � � oo (y � � O MIX-2251/A PHOTO SMOKE DETECTOR � >' �? m �- N J BA7TERY SUPPLIED 40.0 AMPHOURS / DESIGN CONCEPT OF THE PRG,IECT AN� GENERRL � r �y � � P N p � � � Z z FA2.00 RISER / DETAIL PLAN f.ONFORMANCE WITH THE INFORMATION GIVEN IN THE � N O o MS-400U/MIX-M501 DOUBLE ACTION MANUAL PULL STATION � N w � a � �'-� � CONSTRUCTION�OCUMENTS ANY ACTI�N SHOWN IS SUQJ�CT ;.; A ❑P � � _, v� z r- � � v�� * ADDED EQUIPMENT FA3.OQ Tenant Finish Area TO THE REQUIREMENTS OF TNEPLANS AND SPECIFICATID�aS pq W M� � N N ° �� °O � �W � � Z °' GONTRACTOR IS RESPON5IRLE FOR OIMENSIONS WHICH 5tlrlll 7 � � n o Q M M MIX-M500M DUAL INPUT MODULE ¢ W v � Z cn W w -° � ?� p � �� � � m� � � BE CONFIRMED AND COOflDINATEp AT THE JOB 51TE -�-+ a °o � m •• � S2415 15cd VISUAL ONLY WALL MOUNTED � N�. � _ � Q � o �Q p � FABRICATION PROCESSES ANJ TECNPJIf1UES OF CONSTRUCTIOPd � � o m COORDINATION OR WORN {A ITfI THAT Of ALL TRADES AND THE �1j N '�p � � g c� � � � � Q w � w � w � SATISFACTORY PERFURI�7APd � , ,5 a� wQ w� wcn � � � °� a ° 0 q d � � � � ' � �p S2430 30cd VISUAL ONLY WALL MOUNTED �Q �Q j Q j � o ° o� o ° o � ' ❑o -- C�C�F T}iEWORK Z�` r- Z � �` F= v z W z z w ��-. � DATEq�1�..�� a�` -- � � � � � a � � P2475 75cd AUDIO/VISUAL WALL MOUNTED z� c��? ca F- U � w � w o w � c� o N Q ° � p � W N �N P U T Q a a N Q a Q � N � N� N� . . . Q = G O N Z A L E S C G u�U t T l f;,&F N G I N E E R I N G � a v � a PC2475 75cd AUDIO/VISUAL CEILING MOUNTED � � � � � N Smoke Detector X X X � 0 0 o Na �' ° � Thermal Detector X X X � C � ' x x x SCOPE OF WORK 3 Z � o 0 Manual Pull Stotion ; � � y d n , � . -� a � �; • °i REPLACE THE EXISTING FIRE ALARM DEVICES IN THE TENANT FINISH. ALL NEW DEVICES SHALL BE INTELLIGENT W a � � DEVICES AND LISTED WITH THE EXISTING MIRCOM SYSTEM W a � � ,C w Q r�n � � d � Water Flow Switch x X X X ` � Sprinkler Tamper Switch X X � � +' AC Fa�lure X X � circuit snort X X O � � 0 U C�rcu�t Open X X °i Low Battery � X W � W d � N U] C/2 O � O �7 1 CEILING LINE CONDUIT CHART p�D � NO OF CONDUCTORS VOLTS NARE SIZE MANIFACTURER DIMENSIONS AREA 6" 1 TNASTED PAIR 300V �14 AWG ATLAS Z18-14-1-1TP 308 0 D 0744 TIMSTED SHIELDED PAIR 300V �16 AWG ATLAS 218-i6-1-STP 228 0 D 0408 "� SOLID CONDUCTOR 600V #14 AWG TYFE THHN 0641 0 D 003 � ED CONDUC70R 600V ;�14 AWG TYPE THHN 073 0 D 004 � � � � �j ' � H OR N/S TR OB E 1 ATLAS NARE TYPES SHOWN ABOVE ARE U L LISTED ApD C S F M APPROVED � (S F M � 7161-0972 100) o- a Q E FIRE 2 CONDUIT PILL SHALL BE SIZED PER N E C. CHAPTER i, PGS 70-685, TABLE �y4 (SEE BELOW) 0 3 ALL NARING IS TO BE POWER LIMITED CLASS 2 IN ACfORDANCE WITH N E C ARTICLE 760 L� 4 FAN AND DAMPER CONTROL CIRCUIT NARING WHERE 1"OVAC SHALL 8E RUN IN SEPARATE O NOTE: MOUNT HORN/STROBE CONDUIT IN ACCORDANCE WITH NEC 760-29-A2 � ACCORDING TO LOWEST 5 VERi1CLE CONDUIT SUPPORTS SHALL BE PER NEC 3�6-12 AT 10FT INTERVALS . N JO" $O'� D I M E N S I 0 N. 6 U L LABELLING SHALL BE CLEARLY MARKED ON ALL tABLE O � 7 CONDUCTORS IN VERTICAL RACEWAYS SHALL BE SUPFORTED ONE CABLE SUPPORT SHALL A � BE PROVIDED AT TOP OF THE VERTICAL RACEWAY PLUS A SUPPORT FOR EACH 100FT IN7ERVALS AS SPECIFIED IN N E C 300-19(A) 8 CONDUCTORS ARE NOT TO BE SMALLER THAN N016 fOR SINGLE CONDUCTOR, N019 FOR � O TWO OR THREE CONDUCTOR, NO 22 FORE FOUR �2 FUE CONDUCTOR, AND NO 24 FOR 6 OR MORE CONDUCTOR MUL7ICONDUCTOR CABLIS CONDUIT FILL a��� O N �--- MANUAL PULL STATION CALCULATE THE TOTAL AREA OF 7HE WIRE BEING RUNIN THE CONDUIT FROM THE TABLE o00o ii � O N ABOVE CHOOSE THE SIZE OF CONDUIT BASED ON TFE MAXIMUM FILL DIMENSION FROM O � O � THE TABLE BELOW THAT DOES NOT EXCEED THE TOTAI AREA OF THE WIRE O��O 0�0� i N � � NDUIT SIZE MAXIMIM FILI � L C 1/2� 12 SOU�RE INCH ODOO �, O 4'$" 3/4" 21 SOU/RE INCH O�OO ` _ �" 34 SQUIRE INCH �' 1-1/4" 60 SQU/RE INCH ._ C � j 7-1/2" 82 SQU/RE INCH i � w 2° 1 34 SOUARE INCH V a C O FLOOR LI N E FIGURES ARE BASED ON 40% CONDUIT FILL AND ARE AKEN FROM N E G. CHP 9, TABLE 4 POWER LIMITED WIRING w, �i ,W/� C a v RADIONICS EQUIPMENT IS U L APPROVED AND C S F M LIS7 FOR POWER- v! L N L LIMITED INSTALLATION UNLESS OTHERNASE NOTED ALL NARING AND INSTALLATION METHODS � � O C SHA�L CONFORM TO N E C ARTICLE 760 PARTC - PONER-LIMITED FIRE PROTECTIVE � � O O SIGNALING CIRCUITS N � a r Z O � F � CIRCUIT LOADING AND PARAMETERS ALL INITIATING, INDICATING AND SIGNAL LINE (DATA) CIRCUTS, WITH THE EXCEPTION OF 70 NOTE VRMS AUDIO CIRCUITS ARE POWER LIMITED WHEN INSTALLED AS POWER LIMITED WIRING ACCORDING TO NATIONAL ELECTRIC CODE ARTICLE 760, AL. CABLE MUST CARRY A TYPE "FPL"] � � o WIRE RUNS SHOULD BE BROKEN (AS SHOWN IN FOLLOWING DESIGNATION CABLES INSTALLED IN ENVIRONMENTAL AIR P_ENUM SPACES WITHOUT CONDUIT N � QF� DIAGRAM) AT ALL TERMINAL CONNECTIONS TO PROVIDE PROPER MUST CARRY A TYPE "FPLP" DESIGNATION CABLES INSTALED IN RISER SHAFTS WITHOUT Q r� Wo ��� W�W 'O �Z VISION OF THE CIRCUITS CONDUIT MUST CARRY THE TYPE "FPLR" OR THE "FPLP" D=SIGNATION TYPE "FPL" CABLE � �o �Zo MAY BE USED FOR GENERAL PURPOSE FIRE ALARM USE WITHOUT CONDUIT, WITH THE ��W �U =�� EXCEPTION OF RISER OR PLENUM APPLICATIONS FX-200O MIRCOM � �Sa �� �_� W �^WO � W'"o ING MUST BE INSTALLED PER NATIONAL ELECTRIC CODE, ARTICLE 760, AND THE LOCAL � ��� �W �Z AUTHORITY HAVING JURISDICTION O ��� �� ��� Z OQ � �ZU � SHIELDED OR UNSHIELDED CABLE MAY BE USED AT THE DIiCRITION OF THE SYSTEM DESIGNER J ��� �� ��� a Z CARE SHOULD BE EXERCISED WHEN MIXING DATA TRANSMI�SION, TELEPHONE AND AUDIO Q �a�� z€� ��m Z W � CIRCUITS IN THE SAME CONDUIT HIGH LEVEL AUDIO (70 VPMS) MUST BE RUN IN A w � z o�� � � ,� SEPARATE CONDUIT GENERALLY, SHIELDING IS RECOMMENDED IN AREAS WHERE ELECTRICAL U i z W�'U i' = W� O OISE MAY CAUSE INTERFERENCE I E WIRE TRAYS, PLENUMS, RETROFITS OR UNDERGROUND �W''' o��.�, o�"' � w aWZ =G�' p�� r M I STALLATIONS ��= 4U� W � � ��3 =N� �JY � W WHEN SHIELDED WIRE IS USED, SHIELDS SHOULD BE TIED T�GETHER IN JUNCTION BOXES, _�� QN =�� q A AND INSULATED FROM BUILDING GRROUND SHIELDS SHOUL[� BE GROUNDED ONLY AT THE MAXIMUM CONTROL PANEL W�� �mo J a W w 16" � §�� NZW ��m o 0 a a� � N 17 a � a A � A � � � PREPARE WIRE AS SHOWN N N n O � ' o � °' �- N °� � � o `� � O �i � °°� � . '�' O 4 � �1 � � � � � � � � � O m � v = N � Q � a � �� L � LL M ircom PAN E � CON �I GU RATI ON o �^ � �; � o a � o �, „ a — Z c� NO SCALE N 3� V �1 � � � � � � W � � v � LOAD VS. DISTANCE � L = w � INDICATING APPLIANCES CIRCUIT (3.4 VOLT DROP) H� y _ � LOAD MAXIMUM DISTANCE TO LAST APPLIANCE, IN FEET � _ � � CURRENT � � � � J 12 AWG 14 AWG 16 AWG 18 AWG � � 0.1 A 10,625 6,538 4,250 2,615 ('� ) . 0.25 A 4,250 2,615 1,700 1,046 �- "'� �l ��� ,;,.�� � 0.50 A 2,125 1,308 850 523 << O 0 75 A 1,406 865 563 346 1.0 A 1,062 654 425 262 � � 2 0 A 521 327 213 131 � 3.0 A 344 212 138 85 V 0 � T G E D R 0 P 3.5 A 303 186 121 75 CA � CU � ATI ON S f B LII o, � � °� o � • o v t� d � NAC SCHEDULENOLTAGE DROP CALCULATIONS - MAIN PANEL APPLIANCE QUANTITIES CURRENT DRAW � � � N 20� MAXIMUM VOLTAGE DROP � VOLTAGE DROP TOTALS � � o0 V/0 V/0 A/V A/V . TOTAL WIRE ACTUAL ACTUAL TOTAL �,,; A � N 0 � CIRCUIT OUTPUT VOLTAGE = 20.4VAC (FOR CALCULATIONS) ESTIMATED 15cd Wall 30cd Wall 75cd Wall 75cd Ceiling . . CIRCUIT GUAGE VOLTAGE VOLTAGE CIRCUIT � ; � � 0 n � ; m CIRCUlT DESCRIPTION CKT TYPE LENGTH 0.061 0.084 0.172 0.188 . LOAD , � CKT 1 Island Gnll (18,16,14,12) DROP � DR O P (V O L T S) I M P E D A N C E z o �o � m � _ � NAC 300 Feet 2 1 3 2 1 098 14 9.914 2 023 1 842 �2 Q � pp".., °} � R � a -3 . . , �-1 d �u � @� 0o L q . ♦ ' ' • . . . . . . i� o yQm N N � o �- W � � - � � . . . . . � W � a � t° �' g . . w r, a � � ' ' • • . . . . . � � � � z � c� L ' � � o . . . . . . O 0 N � " o APPLIANCE SUMMARY TOTAL LOAD (AMPS) � � Z � � M � � 2 1 3 2 3 � � N � �9$ �NO EXCEPTION TAKEI'J �MAKE CORRECTIONS NOTEQ ' y d n - � �� �iEJEC7ED �'REVISE AND RESUBMIT � °��, � rn � OSU6MiT SPEC1FiED ITEM �j � C � DESICNNGCONCE T EOF GTHERAPROJECTRMANDE WGENERAL �j a V O t � CONFORMANCE WITH THE INFQRMA�'ION GIVEN IN TtiE E-� � W a COGlSTRUCTION DOCUMENTS ANY ACTION SNOWN IS SUaJECT � U x � � � t0 TRE AEQUIFEMENTS OF THE PLANS AND SPECIFICATIQ`J5 Q � V w GONYRACTOR IS RESPONSIBlE FOR. OIMENSIONS WHICH SNALL as SE CONFIRMED APda COORO1NAtED AT THE J06 51TE � COQRDINA710N OR WORf( 4"JITH tFIAT QF ALL TRADES ANU THE fABRICAI'ION PROCESSES AP�D TCCHNIf1UES Of CONSTRU O +' SATISFAC'CORY PERFURiJIA�dC�yti"jH- �t9R '� DATE����L BY ' 0 N � � v GONZALES �Uli�d��, •dGIN€ERING � � a °' F E; W � � x x w � U� O i DATA IN (+) DATA OUT (+) DATA IN (+) DATA OUT (+) p� >+ � DATA IN (-) DATA OUT (-) DATA IN (-) �O� OOO� DATA OUT (-) FROM PREVIOUS DEVICE TO NEXT DEVICE FROM PREVIOUS DEVICE TO NEXT DEVICE � � � �2+� °' � WIRE SCHEDULE � oa > (3+) (1-) a . SIGNALING LINE CIRCUIT A = 2 # y 6 AWG FPL RED / WHITE a , B210LP INITIATING DEVICE CIRCUIT B = 2 # 16 AWG FPL TWISTED PAIR RED / WHITE ° � NOTIFICATION APPLIANCE CIRCUIT C = 2 # 14 AWG FPL RED / BROWN o HORN CIRCUIT D = 2 # y 4 AWG FPL RED/BLACK `` WM H MS DA STROBE CIRCUIT E = 8 # 14 AWG FPL RED BROWN � ° NOTIFICATION APPLIANCE CIRCUIT F = 2 # y 2 AWG FPL RED / BROWN Q ° TELEPHONE CIRCUIT G = 4 # 22 AWG CAT-5 PHONE CABLE ° � 120VAC POWER P = 3 #12AWG CU THHN o N Z d � � B210 � P MS - 4 �1 AD w / MS — DA _ o � DETECTOR BASE DUA � ACTION PU � � STATION � � � y � go � NONE � N O N E � �/�� v � I� r/ w � v a C O � � •- �+ � a � � � � � DATA IN (+) ) DATA OUT (+) W N O O i� DATA IN -) DATA OUT (-) a T � > FROM PREVIOUS DEVICE � TO NEXT DEVICE � � �'i ~ TO INDICATING MIX-M500S � DEVICES AS NEEDED � � PER CIRCUIT � o � o� 9 O 0 QN J O� O 56� 8 9 1 00� �W �zm 8 �[ W � <UJN E W4K � �ZO C+� J O D �/� �hK �� WJ� O 22 KVId' 7 .� 2 75 V I �OW �� WSI% ° 135• 5 i5 ao ISLAND GRILL w ��� WN �Z� �_� TENS 24VDC DEVICESL❑❑P ~ �-� �� ��� 6 s�$9 3 j F P 2 N�TIFICATI❑N p ��^ o 5 TYP TYP TYP TYp TYP TYP CIR C UIT Z °�� � � �� END �F LINE �� �o Z° a FR�M PREVI�US TYP x `� �� p; z RESIST�R IS 47KS� ±10% 3 + 6 1 5 3 2 1 J ��< �W ��� W 5 z� 4 D E V I C E E 2 w m�� o�� ��m � a � �NES � ADDRESS � � �s z ��Z oWW o?� � � � _ CONVENTIDNAL Z�NES �5 EXISTING Z 1�, � + TYPICAL ❑F 8 ZONES P 2 N❑TIFICATION C� g�,� �aW �Q ts� G� W 3C2 1.U2 W�Q � /-' TYP TYP CIRCUIT Z�� 4N� _�� 24VDC T� � 5 �� �W� J�a W � � C 0 N TR 0 � M 0 D U � E NEXT DEVICE �R '�� m END �F LI�E RELAY ��U NzW ��m a F a � I N I T I A T I N G W I R I N G N M Q AQ A D NOT TO SCALE 120VAC P� N DEDICATED � O , . CIRCUIT F A C P � � � a CENTRAL � _ STATI�N �� �� G� o °°`� � r11 � . � � O � � �� � " � � �' °-' 0 V N m � ` � S SP T ; �" � �� L '� Z EC RALERT STR�BE SPECTRALERT H�RN/STROBE Q � a — � '� ,� o �o � �1 � � a c� o m � ��� � Z 415, S2430, S241575, S2475, S24110 P2415, P2430, P241575, P2475, P24110 3 � U �1 � O � FROM (-) �-� T� NEXT (-) C-) �' � ti W "�,'� G� C� W PREVIDUS DEVICE �R HORN (n N� s � a � ONE — � NE DE VICE �+� �+� END �F LINE �+� �+� � � R W DIAGR �, M �C � ,° > J STR�BE ,� � � ,� J NONE �_ �� � FR�M TD NEXT � " PREVI�US DEVICE �R DEVICE END �F LINE O � � SPECTRA � ERT SPECTRA � ERT � � STROBE WIRIN � H �� RN /STROBE WIRING E � , NOT TO SCALE NOT TO SCALE W � � °� o • • o V C� d � • � � o � � o0 � � � ?-' A • � +� N N � � � � ON � � z o oa � m .. � � � P�'� a � � � IL ~ o O o0 0 O a o �1 d � �'+ L C�j N � ° `'' a °D W a CTRALERT CEILING HORN/STROBE � �, �0 EXCEPTIOIU TAKEN �MpKE CORRECTfON$NOTEO � W U� � � � J `` PC�415W, PC2430W, PC241575W, PC2475W, PC2495W, PC24115W a C'J REJECTED M � L � Z CISUBMITi SPECIFfED ITEM w ° � �"{REVISE AND RESUBMIT � O � � � � O � N � M E C+) STR�BE (+> CNfCKING IS ONLY FOR GENERAL COAIFORMANCE WITH TNE � _ � OESIGN CONCEAT Of THE PROJECT AND � � ' � � CONFORMANCE WITN THE INFURMAT GENERAL Z 0 CONSTRUCTION UOCUMENTS,ANY ACTIDN SHOWN NS SUBJEC7 � � � N cu +)- HORN (+) 70 �NE REQUIREMENiS OF THE PLANS A!I(D $P r � � o� n � FR�M T� NEXT ECIFICATION� ' �` PREVIOUS STR�BE O STR�BE (-) DEVICE �R CONTRACTOR IS RESPONSIBlE FOR. DIMENSIONS WHICH SHAII Qi Q f�-,°U � g� CUNFIRMED AND COORDINATED AT TNE JOB SITE � DEVICE END �F LINE FABRlEATION PROCESSES�ND TECNNIQUES OF CONSTRUCTION W � 0 � H�RN (-> H�RN (-) SAtt�€ACTORY ER URP�7AP CE OF THE 6VORKL�TRA�ES ANU THE � � W O a � DA7f��_ V=Z BY A � U � GpNZALES CO \ ING&FN RWG rn � - , w � SPECTRALERT CEILING o � � o M d� � � HORN /STROBE WIRING � G U � NOT TO SCALE h � N w w � W V■ rx o � � w _ 1 �a � � � � � � � � a � • o � � � � � ' S I 75 ¢ O'� I � F I � � � I • N I � J � I Q � � CEILING - 7'6" � CEILING - 8'-0" 0 0 � EXISTING KITCHEN � � _ o y �0 ' � 3 � � � 30 � 0 _ O � � Z � d I v� � N � I � 3 O � � � C C� v J COUNTER � = a � i � - - - - - - - - - - - - - - - - - - - - - - - � C .L � OFFICE y i y L CEILING - 7'6" � � � CEILING - 7'6" W � 0 0 d � o�� a � _ � F HALF WALL � � � EXISTING �- - - - - - - - - - - - �S�,D�D-BA� - - - - - — � � II I r- - - - - - - - - - - - - - - - - - - - - - - - N } � N �� �OJ I � Wo� j= �o= vF3S I I � I � � �g � a I I �mW �U ~�W i I � °�W '� W��^ CEILING - 7'6" � � � � ��� �W ��� I � i Z� so� �j�t ��/1�Zo /y WK Q �~� ` ZOw N-y � I � � � � �� ��� W z 2 � � � $�� �W� °§m � a I I CEIUNG - 9'0" � � �'-� o�W WN? �w� O U � I CEILING - 7'6" � w aWZ =�� °�� I ��_ �.U� W�� �' �" _ •35 I 75 I � C� g�� ZNW �a (� f� �F � U�W g � ��� A Q � BATHROOM � I � Z � '� I w�a r'nm� a�a W w 15 � 3�� NZW ��m f� W a W � �F I � � i CEILING - 3'-0" ' N � � A � A � � � I � I �- - - - - - - - - - - - - - - - - - - - - - - - � I N N � BATHROOM I d1 O �135 I � O I�JF � A ii AI CEILING - 7'6° I o � ^ O � � �� �. - - - - } o � M �� w - - - - - - - - - - � _ li P 0 U ' � „) � O -- � _ --� m p�(1 � �1 ` � Z Q Q •C � � �� �� R LL S' -o N4 � �; ♦+ ` Z EXISTING ,1 0 0 � r BAR CEILING - 9'-0" a c� o rn ' „� � � z � C.7 N y J � �� � O ~ TO REMAIN = o� 3 `� w wz z � � � W � s �„� } � o� x �� �� _ W � = W N �� a � O � J 75 � � � �, v r:,, � � CEILING - �'-0" � �� ■ --� �- � C� I CEILING - 7'6" I �1 I I Q � CEILING - 8'-0" � I � i I � I i I I CEILING - 9'-0" � � I I � , I I �� W t� i I ° � � � \ � °� o ' ■ a � C� � � 0 i i � i �5 � � 00 � r � � , u � 0 n � � Z O o0 �i � o 0 � o ` ;•Y• Ci O �" �"' � N � � a O A � � � R � 00 � � Q o v � m � N o � W a � •► W � � � �o N � � � Q � ,°� � � ° � SYSTEM �AYOU T '� � � M N NO EXCEPTION TQKEN �fI�AKE CORRECTIONS NOTED � � � 0 N � � � A ' � ++ � ++ REJECTED ��PFVISE AND RESU9MIT 1/4 = 1 -0 �SUBMIT SPEC{F{EQ ITEM � � � n � CIIECKING 15 ONLY FOR GENERAI CONFORMANCE WITH THE Q � C 'i UESIGN CONCEPT OF THE PROJECT ANU GENERAL W � C�NFORMANCE WITH THE INFORMATIDN GIVEN IN THE G,�j X Q = � 'Q, TQ THE REQUIREMENTS OF THE PLANS AND SPECIFICATIDNS � �(JPJSTRUCTIDN DOCUMENTS ANV ACTION SNOWN IS SUBJECT Q � W Qo a W � � Ct]t1TRACTOR IS RESP�NSIBIE FOR DIMENSIONS WHICH SHALL �k CONFIRMED ANp COORDINATED AT THE JOB SITE � FABRICATION PROCESSES�'ND TECHNIaIIES Of CONSTRUCTION a, COLI�DINATION OR WOR4( WlTli T OF ALL TRADES AND THE � SA7�SFACTORY PERFURi�",A�!CE TH O � DATE��vLD2 B� � - o O � � GONZALES CON ULTING GINEERINC � U � N 6 W N F W � w " � � o ', _ _ - - —