Loading...
HomeMy WebLinkAboutVail Lionshead Filing 1 Block 1 Lot 7 Unit 6.PDF �v _ _ _ _ _- _ _ _._. a — - - - - - � `�u.�'�h � ��v� �c ;f-Hallway alcove Existing fixed glass --�- � � � � beyond Replace exterior door,�amb � �' , � • � � and threshold with new door �_ � '/ y � � � to match existmg West - Hallwa � Remove carp�t, investigate Bedroom exterior door �� �------�� - Y � ,_ _T__ r existin g slo pm g floor condition (� �, alcove � ; � repair as requred, field venfy _ '� � ' ' . � I i � with Property Manager � � Granite sdi - - --+ --�-- -New wall infitl , �� --- -t--------- -- -- t- I � �( � ; � � bi-fold door ii ---- - - � I� � � �-- ire lace wali Enlar ed i Existm ; t w@St East '� � P 9 9 ' I Bedro Bedroom i i � L� alcove beyond alcove firepiace ! , Car e t � Car e t D '� � ' P ( P � ,, � Granite sill i � h \ Remove existing bi-pass doors , �-- Sheet steei firepla;e surround. �;-Baseboard � instail French doo•s per drawing - - ---, Hallway Elevation Firepiace Elevation field verify design Nith Architect heat cover �:- "� '�j�. �-��- y �- ` ' i � \ / �� �•�� �� / j � Wood tnm on • � � ��: �� '� `� . �,,(� existing pipe column-� So�t -� • � � r �' �- , - --- _ �-�.- _^_�^ - __ �'�� . � � � . � . �. --_ r -�: � , i ; 1 ' � ; I � ; 1 � , , , � -- - - ' - - - - �-- ��G ' ! �°:`.°--� - �a N` , � � �� �� Dining Entry „ , ��' �� � L �; � `i � ( 1 � Q� ?> island I� --�� � � � V v� � , � ;� Mudr � I — -- , T Laundry cabmet � �, Dashed wall mdicates-�- �� � ; y Relocate door to HWH �_� wall to be removed, typ \ � � - --_l� Living/Dining Elevation closet as indicated --——-,-- :l � ' - --— t-+- i-T� a HW{-{, Wet b �and closet � E / ' to be r �oved � I W�� I - � � � _� , � "..' — —' � Soffit--� ' , F Window above �` � ' t Entry �, �� � ; � �� � � � , � Tde �_—I � ' ' i � ant ` I I . ` � ' � Alcove above, - o � access from hall--�- � � � i � Micro � i � � hood s �� Ref '-'r- - � m En(arge existmg ' "New door - `-' � ' alcove � to bedroom Dining Kitchen .�.. , , � � -� ! � Kitchen — � pW i- � -'-�--�' Range i -- I � Tile - - f j � ( 1 .� _ � , �, � 5� � ' f U � i I Living N � South i-� 1 T�ie w � Bedroom � Island Carpet Kitchen Elevation � � � � �� . ? �;° � �--Fixed glass wmdows to mudroom, � �p �o � " f --So�t match existmg window detail � � � ' � f , � ---�- o �. i � _ � � � , , � I � � � � — � � Shaded area indicates Remove existmg bi-fold ! � -- -t =r new construcUon, ty p d o o r s, in s t a l l n e w w a l l � i � � � ' t � Wood tnm on . S h e e t m e t a l i ; � i ecolumn -- -� ---! - —_ -- � Kitchen �I I i surround—�- '� l - �������� P p — , , - ., I ; � Living �,, +, ; qPR 2 2003 Island � ; ' % � � I �) I � - -�------Remove phone�acks--� � ' Ewstm � g and wire from south � � ; fireplace + �� ���-���'���' �In'e bedroom wall and east �� ! � �a hving area wall , � � I I � - � Town o�Vail �' �-New wall infill ; Wood trim on pipe column Living/Kitchen Elevation @ wet bar door -� ����� �� �,1 ' �� � 2* 1NT�RIOR ELEVATIONS 1/4��=��-o�� �,¢ �Ly�( � � , � Peel�Lanc�.�r�lter Architects, L.L.C. Deck David Mark Peel,A I A Kathy Langenwalter,A I A NELKIN REMODEL � P.O. Box 1202 Vail, Colorado 81658 date � g o3 Lodge at Lionshead Phase III Tele 970-476-4506 Fax 970-476-4572 " Unit 6 project . drawn - , Vail, Colorado sheet � of2 1 _ �LOOR PLAN 1/4��=��-o�� r^_.. ' � ' _ -^ '"' T " .._ -. - .. _�-�"_ _ _` _ t -- � -� _ ' _"'- 4 _ `� ' . - ii l � ( � � Existing fixed glass Exist�ng slidmg dwr Existing operable window Existmg fixed glass � � _ �.—_ - - , _ � T ----- � t ____�__ _ _ _ - ---._ !._ _ _ � Remove side trim, ' � ' � � / ;�� typical both sides ��'� � � � =� / I r�- ` Remove trim between T n m b b e T r i m t o b e-f---Y � , , � remo�ed removed , , �- ; r� ^ fixed glass and door _ �..i ' ` `.i� \�� � ' I � t 4 /: � � '�Remove existing �� Tnm and stop to-� f � �-Tr�m to be removed .� � / i � plaster on pipe column ' be removed, typ. � r"--� / � ,� � �---Q� � Existing Window Wall Plan Section Existing sili to be remove�� � � NOTE. Shaded area i�dicates existmg matenals to be removed. , � �_ Existing fixed glass Existing slid�ng dmr Existing operable window, Existing fixed gtass ' - - � �� + � ------# - — __ �,. �---+ � _ ; � ---__ � -----------t }-------- - , 1x wood trim =- ___,_- � _ , �— -- -- � �� - -- � _.`�� �---=- � � � � �_ �-�---- ; ,� �-', � ;j , � �� �� � 1 x wood trim � � / �x wood tnm�-%- ,� ' ' � � Shc trim to be I ____�__ - ,�-- 1 �� _ ____. � ___ _� --- , _--___ _ _ ,�� ' �2 � '� � � T=- Paint o erable y' � 11 \ dete�mmed m field p � � `� ` �� � , wmdow frame � ,� j � �os Ref. \ - � ' � �� �----Finish existing plywood Paint glass-+ � `\ / � � r to match drywall door frame � �--�onceal pipe column Wood stop, typ ->- � . � with wood trim,field Wood tnm, typ. � ,I �� � �� � , �, verify with Architect ' �� R � / � � Revised W�ndow Wall Plan Section �,, , X wood�m �� ! ( � / r NOTE Shaded area indicates new wood tnm =.--Wood baseboard cover � � � + � a / I � IO � � Undercabinet � f I � WtNat�W WALL DETAILS �"=�'-o" � light,typ• j 2 f - , / � � { � f � � � fo � . � � plug mold,typ � ' ` � I) lme of so�t above I Rembve ex�stmg tri 7rim to be y�Exist�ng column �----•Remove upper tnm � � removed � � � � � ` ' Y , I �\ Fixed glass i '�*'� f-Incandescent�xture,--� � ' , � �� recessed downlight,typ. I � Wood valance to Tnm to be F�xed lass � Remove exist�ng � \ ai removed 9 ' 0 erable � o conceal window covering, I - � wlndow ��xed glass stop and tnm, typ ' _ I .----� ' a field venfy with Architect !/rj, I , Shding I ss dcor ; ..�. � °-' �r/ I i � � � � Wood tnm -�- + � ( , - Remove existing tnm J � Wood stop---- �- ' � �i-� # Remove existing tnm � , � Faed glass ,' Fixed glass Ef�-------Incandescent fixture, recessed �__.�__�____. Existmg fixed glass — � � - Remove sill trim ' ����' �--�\\ 1 adjustable trims, typ Wood stop--- � f � l Wood tnm— — ----f---� ' � Existing Window Wall Elevation 1 x wood tr�m----- --- --�-- -- �----1 x wood trirr � Wood valance \ Paint door f�ame� y---Wood trim� pipe column 1 - ' 'ELE�TRICAL LAY4UT 1/4��=��-o�� { Wood tnm � � � ; Fixed g(ass _ Wood stop - ' ? � -- Paint window frame i , r Exist�ng fixed glass � - ' � Fixed glass Fixed glass MATERIALS SPECI�ICATIONS Wood stop —�- � ' i Sliding I ss door Operabie Woad stop and trim � � � Field venfy wood --�--�-�-�- � window typ �fixed glass 4. Kitchen cabinets: Clear alder, natural finish, Shaker style door panel with slab drawer; _ tr,m�s�n w�tn Architect � , Hallmark CL-SFP-1116 OQR-ISQ-slab drawer, 2 '/;' stile, from Thurston, 1 x wood tnm i � —1x wood tnm ! InC. Wood baseboard cove� Fixed gla§s Fixed gfass � 2. Countertops, alcove sills: Granite, Venetian Go1d Exisfing baseboard heat __ _ - __ _ ��.,�-_.:_,�.:_a,� r ._,w:�.�.��_,T_,�.:,-�:�..::�._..,.,;:,wk. ._�„.µ�;., Wood baseboard cover � 3. Appliances: Refrigerator -Amana Easy Reach Plus Refrigerator Model ARB1917C, - �``µ-��W - - • , - stainless steel with black cabinet Range -Frigidaire Slide-In Electric Range Model PLE5389A, Sta�n�ess - Revised Win�ow Wall Elevation NOTE� Shaded area indicates new wood tnm � _ steel with black cabinet Revised Winc�ow Seetion Microwave - Frigidaire Over-the-Range Microwave Model PLMV168K, G stainless steel with black cabinet NOTE• Shaded area indicates new wood tnm WINDOW WALL ELEVATIONS '�14"=��-0�� - Dishwasher-Frigidaire Built-fn Dishwasher ModeIFDB956RB, stainless steel � with black cabinet - 4. Wood trim: Clear alder, natural finish, simple profile, 2 %z' casing, 4 "/:' base. Style as " p?P/( anaern■�r Architect� L L G � approved by Owner. ` . , , DavidMark Peel,A f A. Kathy Langenwalter,A'I A � � � 5. Interior doors: C1ean Iined, two panel, clear a�der, natural finish doors. style as NELKIN REMODEL , P,p,Box 1202 Vai1, Colorado 81658 date l�S�03 � , approved by Owner. ` " - � � _ Lodge at Lionshead Phase lil Te1e970-476-4506 Fax 970-476-4572 project _ ; 6. Baseboard heat covers: Clear alder, natura� finish, simple profile, accessible to heating U�l�t 6 , , � . elements. Verify design with Architect and Property Manager. � � - ` ° drawn , ; - , V�il, Colorado. ; 7. Tile and carpet: As selected by-Interior Designer, - - , � � �- , sheet 2 of 2 G � t _ ,� � � � . . - _ _ _�------___________-------__.__.__.._ �__.___�..._____ ._ ____ - - GENERAL NOTES - _ Contractor is to visit�e site, verify existing conditions, including utility locations, h6okups and stubs, and familiarize himself with all new work. In the event of discrepancies befinreen the � drawings and existing cond�tions, notify the Architect before proceeding with the work. All , work to be performed in accordance with all applicable codes and regulations. The Contractor shall �emove from the site and safely store all fumiture, fumishings and personal property of he Owner that is currently in the unit and scheduled to remain. The Contractor shall remcve from the site and dispose of all demolition materials, debris and rubbish as soon as p�acticable. Protect all existing areas from the new work and repair all damaged work that isto remain. _The building and grounds shall be kept clean at all times. Interior detailing, finis�es and materials; including material and performance specifications, are to match existing�r as selected and/or approved by the Owner or Owner's Representative. The� include, but are not limited to, floor flnishes, doors, hardware, trim, closet systems and shelving, fireplace surround, built-in furnishings, cabinetry, appliances, lighting fixtures and trm, sound and security systems Provide blocking as required #or proper installation of Mese items Mechanical and electacal systems design shall be the responsibility of the General Contractor, required subcontractor or others as selected by the Owner ' The Architect assum� no responsibility for errots, omissions and applicable code requirements of cons�ltants. The Architect assumes no responsibility for utility coordination, �- care of ad�acent p�operties, performance specifications and the components of construction safety, nor for the Cortractor's failure to carry out the work in accordance with the Construction Docume�ts. � � The investigation of hazardous materials is beyond the scope of these Architectural Services. The Owner shall be responsible for all existing hazards on the property; and for the discovery, presence, Fandling, removal or disposal of or exposure of persons to hazardous m�terials, waste or su�stances in any form on the property, including, but not limited to, asbestos, asbestos pr�ducts, etc Ownership and possession of the original Architectural drawmgs shall remain that of the Architect. Reproducibe copies will be provided at the Owner's request and expense These drawings are not to beused on other projects except on agreement in wnting and with appropriate compensa�ion to the Architect. CONSTRUCTIDN NOTES 1. Remove flooring frcm west bedroom to investigate existing sloping floor in northeast corner. Notify Property Ma�ager and Architect when the floor is exposed. Determine solution to problem and repairas required. 2. Remove existing kiichen appliances and cabinets, install new apphances and cabinets per plan. Provide electical as required by code and as indicated on the pfans 3. Remove existing wet bar and closet; modify laundry closet as mdicated to create mudroom � � . Reroute plumbing � required. Construct walls as indicated. Install fixed glass windows at - top of wall betweenmudroom and living; match existing detail. Provide cabinet for laundry `�` closet, field verify design with Architect. Provide lighting and electrical in mudroom as required by code ard as indicated on the plans _ � 4. Remove existing dcor to HWH closet and relocate as indicated. Patch wall as required. Relocated lighting and switch as required. 5. Remove existing fireplace hearth and mantel. Eliminate small closet in bedroom and create lower and upper alwves as indicated on the plans Field verify alcove sizes and finish with � Architect after demclition. Install door to bedroom. Install sheet metal surround to fireplace, field verify size and�etailing with Architect. � 6. Remove existing kit,hen, dining, living lighting, install new lighting as indicated on the plans Remove exiting teleahone jacks and wire from south wall of south bedroom and from east wall of livmg area. I�stalf telephone service are indicated on drawings. 7. Provide cost option �o replace existing sliding glass door in living area with new sliding glass door. Verify manuf2cturer with Architect 8. Remove window trirn and stops #rom living/dining window wall as indicated on the drawings Install new wood trin and stops as indicated. Field venfy sill and baseboard heat cover , detaihng with Architect. 9. Remove existing plaster from both pipe columns. Trim with wood, field verify detailing with Architect, 10. Replace.�If interior coors, casing, door hardware and base trim throughout unit. Existing bi- • pass docsrs at bedroom closets to be changed to French doors. Install wood casing around east exterior door ofmudroom. Doors, hardware and casing as approved by Owner 11. Replace existing pato door, �amb and threshold in easf bedroom with metal door to match west bedroom door. . _ 12. Replace casing at bedroom windows and patio doors, install new wood sifls at both patio � doors. Field verify d:tailing with Architect. , 13. Remove any existinc trim at baseboard heat, provide new wood baseboard heat covers throughout unit. ' 14. Remove existmg flocring material in entry, kitchen, livmg, dining areas, mudroom and three i ; bedrooms. Install tile throughout mudroom, hallway, living, dining, kitchen and entry. ' Carpet in each of th�three bedrooms. Bathroom flooring does not change, however base trim does. 15. Texture and paint drywall throughout unit. Replace all electrical switch plates and outlet covers. Clean existiag paint from existing switches and outlets. a � NELKiN REMODEL • � Lodge at Lionshead Phase Ifl, Unit 6 � - Vail, Colorado