Loading...
HomeMy WebLinkAboutM02-0242.PDF �, FLAG NOTES � - f� 1� MOUNT BOTTOM OF EXHAUST FAN 12° A F F. Alvine and ', � �2 PROVIDE 14 GA STEEL FRAME, 1/2"x1"x16 GA EXPANDED Associates Inc. �, METAL SCREEN WITH REMOVABLE REAR PANEL ON MOTOR ��� SIDE OF PROPELLER FAN e�8 3� INTERLOCK MOTORIZED DAMPER WITH ASSOCIATED EXHAUST 1102 Douglos On The Moll FAN Omaho, Nebraska 68102 4�2/346-7007 Fax 402/346-9576 GENERAL NOTES 1• WSTALL CARBON MONOXIDE SYSTEM PER MANUFACTURER'S RECOMMENDATIONS (� C G � � � R T � a 1 ; � a ,�, o . , , �� i t'� 3 GARAGE EXHAUST �� ° �-� PROVIDE TURNING ° A � %" 14,000 CFM VANES IN EXISTING , 36"x36" CONTROL DAMPER Mt_0 �T� CONCRETE AREAWAY a M 1/2°xt"x16 GA EXPANDED METAL � 14 13 I 2 11 0 9 8 i 6 5 4 3 2 1 "� ��"�� � / ��SCREEN WITH 14 GA. STEEL FRAME � R�� � � % � GARAGE � � j � EXHAUST AIR � _� � � �~� �� =� � \ GARAGE FLOOR � ��� \ a � � e � � � EXISTING 36°x36" SUPPORT CONTROL DAMPER OPENING IN WALL FROM WALL WITH ANGLE IRON SECTIUI� A SCALE: 1 /4"=1 '-0" M1.0 � l STAIR � CARBON MONOXIDE HIGH LEVEL ALARM ��� „H„ E STING EXI TING EXISTIN RAMP S CAR ON MONOXIDE DETECTO (TYP) ,, CO-1D ; � co CO-1C oi�ER Roorn - NIC �� L ��� > X � I � ,,, 15 16 17 X ELEVATOR 18 19C ZO HC HC `'� LOBBY 2 �� \ �,_. 1 � � EF-4G � � 7 1 � l S EF-3G � , 1 �CARBO ONOXIDE HIGH EVEL ALARM �Y 2 � 31 3� 33C 34 35C 36C 37 38C 39 I � � � � � CO 1E CO-1F � , ���:�:g: �=�- STORAGE �� r � � ) „�� � ` � � � { f ^ � . � .,�-y ,�w� � i J � � � � �--"---� � ` �� . I' --�f• %�� �// � i ` � � . � � � �':`. . 1 22 ?3 24 L5 26 27 28C 29C 30 STGRAGE I' � � � ` J � ,° _-��� �' � � � � STAIR � ,�„ � � . 4 � _ '" ��t� �� • �/ Q�2 � � P�l�M I''�, `� , PLAN NOi2TH ����f�l �l I ��� ���� `� �������� l �� I = � I I 1 / sca�� va�� , �,_m,� . � � p0 RE�s ` � � oes• � ' � COPYRIGHT AA # 20026246 11�05�2002 `" +v4��°��1 , ` ee • Permission to reproduce all or part of this Drowing - G��`� 2 O is hereby granted solely for the I�m�ted purpose of construct�on of th�s pro�ect or orchiv�ng ' �� m� Unauthonzed copying, d�sclosure or construct�on use ° o� without written permiss�on of Alvine & Associates, .•'�� '°�......o° � Inc is prohibited by copyright law ss/ONAL� � NOTE: �� DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS ond KEY PLAN clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site Loy out and coordinate all work prior to installat�on to provide cleorances required for operation, mointenance, and Sh��t Numb�r codes and ver�fy non—�nterference with other work DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICATIONS N ' 1102 Douglos On The Mall , Om oha, Nebraska 68102 ° 402/346-7007 �� Fox 402/346-9576 Alvine and Associates Inc. engineers and consultanta 11—OS-2002 15 O6 20026246M10 dwg nhoesing � 1 - - -- ---- - - ' , , ». .. � -�" �� ' GENERAL NOTES '� Alvine and ,�� 1. INSTALL CARBON MONOXIDE SYSTEM PER MANUFACTURER'S Associates Inc. RECOMMENDATIONS. engheers and correuttants 1102 Douglas On The �lall Omaho, Nebroska 68102 402/346-7007 Fax 402/346-9576 � � � L � �' 1 � R T �) 1 � �, � A GARAGE EXHAUS 11,4�0 CFM 13 12 11 1 g 8 7 6 5 4 3 2 1 M1.0 PARKING STAIR GARAGE "H' GARAGE RAMP CARBON MONOXIDE HIGH LEVEL ALARM S CO DETECTOR (TYP) �` � CO-1B co CO-1A �� 2 EXISTI�IG �,�, // DELIVERI' MECHANICAL II II// BAY ExIST'G ROOM EXISTIN 11 �� PHGNE ELEVAT R � ROOM LOBBY 15C 16C 17C u � DRYEF2 STORAGE CAGE HOUSEKEEPING � —� ❑ STORAGE � 3 � � NEW ENGWEERING OFFIC "� � DEFARTMENT SPAC � � TOOL � � ROOM � N I C OFFIC � SPAC EXISTING Sw'I TUNING � � & STORAGE TO REMAIN � II � � 11 � NIC � � _ � � � � � � � � � �IIIIII � HAN ,ING II II II � G C � � � 'ROOM �� ,� \� � � � � �� 1� \, �1' � EYISTING EXISTING � � GIFT �HOP S4•'I BOOT OFFICE STORAGE ExISTING RENTAL � � N I C fJ I C & REPAIR TO REMAIfJ � — � � , � � � � �� � � EXISTING GIFT SHOP TO REMAIN N I C � BAR � a � 5 STAIR "J' � ,� . � � � Da t� �� NOV �2 i��1�M I fi ��� PLAN NORTH i������lf��� ����1 = ������1 ����� ��� ' _ � 1/� " � SCA�� I/8" = I'_m" � Pp0•RE�� m COPYRIGHT AA # 20026246 11/05/2002 OQ:• �,-�° e Permission to reproduce oll or part of this Drowmg , V����1�N/ A ;�� is hereby granted solely for the limited purpose of y �� f m� construct�on of th�s pro�ect or arch�v�ng . o Unouthor�zed copymg, d�sclosure or construct�on use o� without wntten permission of Alvine & Assoc�ates, . ao��C,�' Inc �s prohibited by copyright law ss/ONAI-E��\ � 1 NOTE: - ���� DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS and KEY PLAN clearances from ARCHITECTURAL, STRUCTURAL, shop and other appropriate drawing or at site Lay out and coord�nate all work prior to installation to provide clearances required for operation, maintenance, and 5h��#. Numb�r codes and verify non—interference with other work. DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICATIONS N ' 1102 Douglas On The Moll , Omaha, Nebroska 68102 ° 402/346-7007 �� Fox 402/346-9576 Alvine and Associates Inc. engmeere and consuftants � 11—OS-2002 15 OS 20026246M11dwg nhoesing , �I , _ � t GENERAL NOTES �� Alvine and ,�� _ 1 INSTALL CARBON MONOXIDE SYSTEM PER MANUFACTURER'S Associates inc. RECOMMENDATIONS er�heers and correultaMs 1102 Douglos On The Moll Omaha, Nebrasko 681�2 — 402/346-7007 Fax 402/346-9576 � ; � h � FAN SCHEDULE z ? MARK EF-1G EF-2G EF-3G EF-4G � SERVES GARDEN LVL. GAR BASEMENT GARAGE BASEMENT GARAGE BASEMENT GARAGE LOCATION SEE PLANS SEE PLANS SEE PLANS SEE PLANS i TYPE CENTRIFUGAL CENTRIFUGAL WALL WALL CLASS - MAXIMUM WEIGHT (LBS) 500 500 2�5 2�5 EF-2G�\ �Ef-1G AIRFLOW (CFM) 11,000 14,00� 11,000 11,000 TOTAL SP (IN. W C) 0 5 0 5 0125 0125 WHEEL TYPE BI BI PROPELLER PROPELLER 6" HIGH REINFORCED 12 WHEEL DIA 30 30 36 36 MAX HEIGHT 7'-6" �GAUGE CURB OVER EXISTING MINIMUM ABOVE GRADE EXHAUST AREAWAY MAXIMUM FAN RPM 725 870 610 610 MAXIMUM FAN BHP 2 2 3-6 �-6 �6 �� , MAXIMUM SONES 20 0 27.0 21.0 21_0 HP 5 5 3�4 3�4 / � VOLTS 200 200 200 200 � � � � � � EXISTING EXHAUST AREAWAY / \ MOTOR � � � � \ \ PHASE 3 3 3 3 � � � � � � � � � � � � � � � � � DATA T�E O.D P. 0 D.P_ 0 D_P. 0 D P � � � � � � � � � � � � � � � I I I I I I I I I I I I � CONTROL DEVICE (BY OTHERS) - - - � � � � � � �' \ — , , , , , , T� EXISTIfJG LANTER � i i � i i � � \ ROOF/WALL OPENING SIZE - 43x43 43x43 L_1___�vj�____L_1___����----L_J ' - � 5 MANUFACTURER COOK COOK COOK COOK ' � � EXISTING ALKWAY - 300TLC-B 36XMW 36XMW \�// MODEL NUMBER 300TLC B � REMARKS (1) (2) (1) (2) (3) (1) (4) ��) �4� S E CT I 0 N A REMARKS M�.2 \ 1 � (1.) FAN SELECTED @ 8500 FT ALTITUDE, 70'F TEMPERATURE. SCALE: 1 /4��='I �—O�� . � (2.) PROVIDE FAN WITH: .�� ��� u >. `, EF-2G -STANDARD DISCONNECT SWITCH r I'`y��'� ,� � � -MITERED CORNERS - (3) REINFORCED WHEEL_ � 4 PROVIDE FAN WITH WIRE GUARD ON PROPELLER SIDE II;�I'� �,� EF-1G � ) o � A � ---� M 1 2 '� � � � � COLORADO .� � LOADING BANLIRC GM � DOCI< � NIC � � � � '��� . STAIR � " � „H„ � LOCAIE �COLUMN LOCATE ON WALL E Q U I P M E N T � WEST OF WEST OF — DELIVERY BAY ELEVATOR LOBBY 7pg Q{Y Paft # Supplier Description CO-7A CD-1B CO-1 6 CM-21A MACURCO CO DETECTOR RIB-1 2 RIB2401B INVENSYS SPDT RELAY-IN-A-BOX 24VAC MACURCO MACURCO TR-1 2 694-M2 KELE 700VA MULTI-TAP TRANSFORMER � � GAS DETECTOR GAS DETECTOR S E Q U E N C E 0 F 0 P E R A TI 0 N ,_ � C M-21 A C M-21 A GARAGE CO DETECTION I THE MACURCO C�A-21A (CO-1) CARBON MONOXIDE DETECTOR MONITORS THE PARKING GARAGE FOR CO LEVEL � � I � �r r � �¢ a IF CO LEVELS AS MEASURED BY ANY ONE SENSOR, INCREASE TO 25-35 PPM (ADJ) AVERAGED OVER 5 �� � IIIIII I a� z� a a� �� a a� �� MINUTES, THE CM-21A OPENS THE GARAGE DODR AND STARTS THE GARAGE EXHAUST FAN ,.{ .-�I., ,.{ �.{ WF1EN THE CO LEVELS FALL BELOW THE SET POINT iHE i'AN IS TURNED OFF AND THE DOOR IS CLOSED � J �--14-I1 � I LOCATE IN FAN R00lA I I I'� w"I I I I'� w'� THERE IS A MINIMUM DF 5 MINUTES DELAY BETWEEN ON AND OFf TIMES TO MINIMIZE SHDRT CYCLE OF B-1 NORTH °w °w w w � � � � w w � � EXHAUST FAN AND DDOR OPENERS / � � r Y m m � rc > r m m ��� � � � TR-1 PROVIDE ALARM REL A Y A T 1�0 ppm OF CO AFTER 30 MINUTES AND SOUND BOTH AUDIO 5T AIR � AND ViSUAL NOTIFICATION OF HIGH LEVEL OF CARBON MONOXIDE wITHIN ASSOCIATED >>�,� � II II II v�RiFY -- � - ------ - ------ - ------ GARAGE AREA (VERIFY WITH BUILDING OWNER IF REMOTE ALARM SIGNAL IS REQUIRED) "�' � .��— I ---------- (( 11 ------------------------------------ VOLTAGE __ N -------1------------------------ ---—----------- ------ -------- `A_J� I i ------—------- -------------------------------------� f � I � i � PARKING GARAGE (GARDEN) CARBON MONOXIDE DETECTORS � � � � , � � � � --, � ------------------------------------- � i r----------- � i i � i � i � i i � i 480 3� � GARAGE � � � � � L7 L2 L3 � DOOR � i i � OPENER � i i RIB-� ORG � L- W g RIB-� ORG __ M i �---------------------�--- W B o �� -- YEL i i PLAN c �� -----H 12DVAC W y � BLU _, � � NORTH � � � --- W Y BLU � r--- � i i � i i i 1 ' I I I �1 ��1 !� ���� � \ ��� I — � �� 1 � � EF-1G � , � , � M MOTDR SOUTH ; pOWER S P Y � _ � M����i� f��� ���1� �, � i BY E C � / i i � i � � � i � i ' SCALE I/8" = 1'-0" � ------- L__________________________________________________�______-_-__-_-________ � LOCATE �COLUMN LOCATE ON WALL LOCATE �COLUMN LOCATE �COLUMN WEST OF WEST OF WEST OF EAST OF V-2 CLCVI.TOR LOBBV L-d R-4 co-ic co-io co-ie co-iF MACURCO MACURCO MACLIRCO MACURCO GAS DETECTOR GAS DETECTOR GAS DETECTOR GAS DETECTOR CM-21 A CM-21 A CM-21 A CM-21 A �' a� z� � a� z� � a� z� o aw aw � a� �� °a a¢ �� a° a� �� a arc 4� a I., p� /� LOCATE IN FAN ROOM I I �� �h I I r'h I�� � I rh rh I � ��I �h B-'I NDRTH ° °w w w j � °w °w w w � ¢ ° ° w w � � y/C�tCei �� N�V SL/ ¢ ¢ r r m m ¢ ¢ r r m m ¢ ¢ > r m m ¢ ¢ r > m m TR-1 i��i�Ml`� �� VERIFY -- � - ------ - ------ - ------ _________________ _______ ________ ____________________ _______ ________ _______ ________ VOLTAGE __ N -------Z---- ---------------- --------------------� ---------------- --------------- i � i � � PARKING GARAGE (BASEMENT) CARBON MONOXIDE DETECTORS � , � � � � ' ------------------------ ' � �-------------------------- � G�DORE i � � i � i � OPENER � � RIB-1 � i i 480 3� �__- W g ORG __ _�` ,, � i � Li t2 u � YEL , v i I 1 I � W Y BW � � � � RIB-1 �--- i � � � W B ORG a o � �----------------------1--- � i ' i � YEL _ _ H 120VAC i � i i � W Y BLU � � � v � i i i POWER SUPPLY i , EF-2G , BY E� , ; EF-3G ; ; o0 � M MOTOR EF-4G � ; �Q.P��..e.. �,i m COPYRIGHT AA # 20026246 11/05/2002 � � � So�TH � , Permission to reproduce oll or part of this Drowing %� v�;�J ' ° a ' --------------+-----------------------------� Y 9 Y s �--------------------------- ______---- is hereb ronted solel for the limited purpose of ; ;� � m�g construct�on of this pro�ect or arch�ving .v� 84 ; Unouthonzed copymg, d�sclosure or construct�on use � ;� ' without wntten permission of Alvine & Associates, .� .e°�� Inc is proh�bited by copyright law , FSS�Q���EN�\ NOTE: - � DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS and - - - , KEY PLAN cleorances from ARCHITECTURAL, STRUCTURAL, shop and \� other oppropriate drawing or at site Lay out and coordinate all work prior to mstallation to provide clearances required for operation, momtenance, and Sh��t Numb�r codes and venfy non-interference with other work DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICATIONS N ' 1102 Douglas On The Moll o� , Omaha, Nebraska 68102 402/346-7007 �� Fox 4�2/346-9576 Alvine and Associates Inc. engmeers and consultants 11-OS-2002 15 14 20026246M12 dwg nhoesing ' 1