Loading...
HomeMy WebLinkAboutBUFFEHR CREEK LOT 39 2000.PDF AT&T AT&T WIR SS S RVIC S SITE N0 . 2 - 056 VAIL I AT&T Wireless Services WEST SUITE C-1 1001 16TH STREET All a; DENVER, COLORADO 80265-0003 2077 N . FRONTAGE R D . VAIL , COLORADO 81657 ROOF - TOP ANTENNAS AND EQUIPMENTIROOM r PROJECT TEAM PROJECT SUMMARY DRAWING INDEX SYMBOLS J� 'X PROPERTY OWNER SITE ADDRESS TITLE SHEET __ __ PROPERTY LINE T-1 TITLE SHEET JAYNE BRANDESS REVOCABLE TRUST 2077 N FRONTAGE RD. X X X X X FENCING f 41184 HWY 6 VAIL, COLORADO 81657 AVON, CO 81620 IT AL —E E E— ELECTRICAL SERVICE HOME PHONE. NA A-1 SITE PLAN WORK PHONE: (970) 949-1636 —T T T— TELCO SERVICE CONTACT. BRIAN O'REILLY A-2 ENLARGED SITE PLAN01 I , CODE BLOCK KDC A-3 EQUIPMENT ROOM AND DEMOLITION PLAN (N) NEW Architects – Engineers, P.0 APPLICANT SITE LOCATION: 2077 N. FRONTAGE RD q-4 CONSTRUCTION, FINISH, AND CEILING PLANS 12250 East Iliff. Avenue, Suite 302 VAIL, COLORADO 81657 (E) EXISTING Aurora, Colorado 80014-1253 303 750 6999 FAX 303.750 0236 AT&T WIRELESS SERVICES A-5 ROOF PLAN Email: kdcdenver @kdcarchitects cam SUITE C-1 JURISDICTION. TOWN OF VAIL XXX A-6 ELEVATIO S A DETAIL REFERENCE SYMBOL e si e; www carc i ec s.com 1001 16TH STREET 75 S. FRONTAGE RD DENVER, COLORADO 80265 VAIL, CO. 81657 A-3 (303) 573-3277 (970) 479-2100 A-7 ARCHITECTURAL DETAILS AT&T WIRELESS SERVICES CONTACT: JEFFREY W. RINEHART BUILDING CODE 1997 UNIFORM BUILDING CODE A-8 DUMPSTER CORRAL SITE PLAN A Al2 ELEVATION REFERENCE SYMBOL "PROJECT APPLICANT AGENT 1996 NATIONAL ELECTRIC CODE A-9 A 2101020 003 PROPOSED EQUIPMENT OCCUPANCY B 2 07 UNMANNED TELEPHONE EQUIPMENT AND ANTENNA A-2 PLAN REFERENCE SYMBOL 7354 S WALKER COMMERCIAL ( � A-10 A rer,1112 NOR 11 M- IIIIIIIIIIIIIII ENGLEWOODG COST 80112 WATER SUPPLY: NONE/WASTE WATER: NONE/PLUMBING. NONE STRUCTURAL 0 KEYED NOTES JHR TEL- (303) 680-6600 S-1 SCREEN FRAMING DETAIL `NO DATE ISSUE) FAX (303) 680-2179 ELECTRICAL PUBLIC SERVICES CELL 303 905-4444 – I TAI ® 1 00 CLIENT REVIEW ZONING ( ) TELEPHONE. U S WEST S SCREEN SEC ONS AND D LS GROUND ROD WITH ACCESS 03 03 REVIEW/ ZONING RALPH WALKER 2 04 21.00 ZONING THE PROPOSED PROJECT INCLUDES S-3 DUMPSTER CORRAL FOUNDATION PLAN AND SECTION 0 XIT GROUND ROD 3 053100 ZONING REVISION 4 06 19 00 ZONING REVISION CONSTRUCTION MANAGER PROVIDE AT&T EQUIPMENT ROOM IN EXISITNG BUILDING. S-4 DUMPSTER CORRAL FLOOR PLAN AND ELEVATIONS ® GROUND ROD 5 062300 RF REVISION 06.27.00 ZONING " CONSTRUCTION TO BE ONE HOUR RATED MECHANICAL j $ 07 11 00 OWNER REVISION AT&T WIRELESS SERVICES �� DISCONNECT SWITCH 10 19 00 CONS RUC ON/REVISION �- SUITE C-1 M-1 MECHANICAL DETAILS, NOTES AND SCHEDULES 9 11.07.00 CONSTRUCTION/REVISION 1001 16TH. STREET INSTALLATION OF AT&T ANTENNAS ON ROOFTOP. METER ON METER/ BREAKER UNIT M� 12.2000 CONSTRUCTION/REVISION M-2 MECHANICAL PLAN DENVER, COLORADO 80265 01 2501 CONSTRUCTION/REVISION (303) 881-7386 3 SECTORS/ 4 ANTENNA PER SECTOR/ 12 TOTAL; 1 OMNI ANTENNA, ELECTRICAL CONTACT. DON WILL CIRCUIT BREAKER i COAXIAL CABLE RUNS FROM ANTENNAS TO EQUIPMENT ROOM; E-1 ELECTRICAL SPECS, NOTES, SYMBOLS, ABBREVIATIONS, AND ELECTRICAL SITE PLAN ARCHITECT / ENGINEER A NEW TELEPHONE SERVICE RUN TO THE EQUIPMENT ROOM, E-2 DEMOLITION PLAN GEN GENERATOR KDC ARCHITECTS ENGINEERS, PC. A NEW 400A ELECTRICAL SERVICE TO THE EQUIPMENT ROOM; E-3 POWER, LIGHTING, GROUNDING PLANS, AND NOTES 12250 E. ILIFF AVE SUITE 302 CAD WELD TYPE CONNECTION 0 w All dran s and written material contained AURORA, COLORADO 80014 AT&T PROJECT AREA IS APPROXIMATELY 960 SQUARE FEET E-4 ONE–LINE DIAGRAM, PANEL SCHEDULE AND NOTES herein may not be duplicated used or disclosed (303) 750-6999 without the written consent of the architect (303) 750-0236 FAX E-5 DETAILS AND DIAGRAMS � COMPRESSION TYPE CONNECTION ken camp @kdcarchitects com LAT 39°37'59.2"N E-6 DETAILS KUM I ki I e an CONTACT. KENNETH D. CAMP LONG 106°24'48.8"W —— —— -- —— — GROUND WIRE E-7 DETAILS WEST VAIL -� 2077 N. FRONTAGE RD. APPROVALS VICINITY MAP VAIL, COLORADO 81657 LEASE AREA DESCRIPTION NO SCALE DIRECTIONS T ® SITE � L SITE PARCEL NO.: – TAKE 1-70 WEST TO VAIL, TAKE WEST VAIL EXIT x{173, PROCEED EAST SITE NAME: WEST VAIL � PAST CITY MARKET TO BRANDESS BUILDING AT 2077 N FRONTAGE RD. WEST LEGAL DESCRIPTION: AT&T APPROVAL LEGAL DESCRIPTION – ENTIRE PARCEL LOT 39, RESUBDIVISION OF BUFFER CREEK, COUNTY OF EAGLE, DATE ASQ�� ROOF—TOP ANTENNAS & STATE OF COLORADO, EXCEPT DEPARTMENT OF HIGHWAYS, REAL ESTATE APPROVAL - � STATE OF COLORADO, PARCEL NO. 16 REV. 2, PROJECT EQUIPMENT ROOM NO 1 70-2(7)1 B3,ACCORDING TO CIVIL ACTION NO 1481 IN THE DISTRICT COURT IN AND FOR THE COUNTY OF EAGLE, STATE OF COLORADO DATE �ON��-�P 7� ���� CONSTRUCTION APPROVAL SAP - = ' �'� .4 SHEET TITLE DATE SITErr� RF APPROVAL �� / o C040� TITLE SHEET LANDLORD APPROVAL DATE S� �P , � ENN 1FH i i 113-�l39 SHEET NUMBER DATE ' <� ��b o\ \��V� EQUIPMENT ENGINEER APPROVAL NORTH SSED ARAN .0l� 1 DATE NTS 24445-7DE-2056–T01-11 S S e AT&T AT&T Wireless Services SUITE C-1 / ' \ 1001 16TH. STREET \ \ DENVER, COLORADO 80265-0003 O \ \\ ■ Ile / r TELE. PED KDC �� / / ,�' \ T ---r T � Architects — Engineers, P.C. i \ / / \ 12250 East Iliff Avenue, Suite 302 � Aurora, Colorado 80014-1253 / 303.750.6999 FAX 303.750.0236 , \ / / / 6', \ \ Email: kdcdenver®kdcarchitects.com i ` / .s \\ Website: www.kdcarchitects.com / , J / � ' ' - \ AT&T WIRELESS SERVICES ell / i ��` � &D / / ,��C� ` \ 2101020 003 \ / \ Ica coq' 1 2'x3.3' INLET JHR / / loo, P� QP��� / / 1 03.03.00 CLIENT REVIEW ZONING �+ 1100 // S 2 04.21.00 ZONING 3 05.31.00 ZONING REVISION ` TV RIS ` / `� STAIRWELL 19 a 4 06.19.00 ZONING REVISION 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION WV 07.11.00 OWNER REVISION CD ��9 / / 10.19.00 CONSTRUCTION/REVISION 11.07.00 CONSTRUCTION/REVISION 10'-0" x 8'-0" DUMPSTER ENCLOSUR �� \ / / Off( Off( 12.20.00 CONSTRUCTION/REVISION 01.25.01 CONSTRUCTION/REVISION DUMPSTER-6'-0° W. x 6'-8" H. x 5-6" D. \yam � �\ ,' �\O\v �O\'' � �h � C \ A, 9' HIGH CEDAR FENCE. W/ (2) 4'-6° GATES. \ / / hereinamay no) ber�duplicate�ri ulsed noarindisclosed \ without the written consent of the architect. >o, \ FH WV WEST VAIL 2077 N. FRONTAGE RD.. �p VAIL, COLORADO 81657 PLATTED / = 00"03'13" R= 5910.00' ROOF—TOP ANTENNAS �C L= 5.53' EQU PMENT ROOM CHD= S47 e 21 15 W P&M= 5.53' N37°15'30"W MEASURED 0.90' = 00 001 '31 " R= 5910.00' L= 2.61 ' SITE PLAN CHD= S47°02'03"W 2.61 ' SITEPLAN SCALE: 1"=15'-O" KE .E V ll�l ' B-1139 � ,�II � r, ` w �S�D A�GN\ 24445-7DE-2056-AO1-11 1 AT&T AT&T Wireless Services SUITE C-1 1001 16TH. STREET DENVER, COLORADO 80265-0003 N ■ 1 K C I IA13 I Architects — Engineers, PC. 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 Email: kdcdenver®kdcarchitects com Website: www.kdcarchitects.com EXISTING WALLS TOI 1 2 3 4 5 6 7 a 9 10 AT&T WIRELESS SERVICES BE REMOVED I D 21 01020.003 I � EXISTING TRANSFORMER I I . II I I I JHR PROPOSED AT&T DUMPSTER ENCLOSURE o EQUIPMENT ROOM 10'-0" x 8'-0' I SU E B ( STORAGE I I I I I I 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING SUITE "A" z BRANDESS RETAIL AND PROFESSIONAL BUILDING 3 05.31.00 ZONING REVISION 4 06.19.00 ZONING REVISION I 1 I 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION 07.11.00 OWNER REVISION DUMPSTER — 6'— "W. x 6'-8"H x 5'-6"D. 10'-0"7 7'-6' 1019.00 CONSTRUCTION/REVISION o 9 11.07.00 CONSTRUCTION/REVISION 1 C — — — 12.20.00 CONSTRUCTION/REVISION 01.25.01 CONSTRUCTION/REVISION 9 HIGH CEDAR FENCE/ B — W/(2) 4'-6" GATES o ELECTRICAL 17'-6' EXISTING BEAM FURRED OUT I EXISTING CONCRETE SIDEWALK m All drawings and written material contained herein may not be duplicated used or disclosed without the written consent of the architect. EXISTING COLUM WEST VAIL A I — I I — � — — — � — I — I s PROPOSED WALL 2077 N. FRONTAGE RD. 1 HR RATED VAIL, COLORADO 81657 CONSTRUCTION — I PROPOSED WALL 1 HR RATED CONSTRUCTION EXISTING CMU WALLS ROOF—TOP ANTENNAS 8c I 2068 WOOD DOOR & JAMB W/ EQUIPMENT ROOM LEVER HANDLE HARDWARE EXISTING PARKING PROVIDE WINDOW BLINDSI TO MATCH SUITE "B" ENLARGED SITE PLAN D 9Q ENLARGED SITE PLAN KENNETH D SCALE: 3/16" = 1'-0" { CAMP y : B-1139V� .r 24445-7DE-2056—A02-1 1 AT&T AT&T Wireless Services SUITE C-1 1001 16TH. STREET ' DENVER, COLORADO 80265-0003 K C \ Apo Architects — Engineers, P.C. / \ 12250 East Iliff Avenue, Suite 302 / Aurora, Colorado 80014-1253 r \ / 303.750.6999 FAX 303.750.0236 0 Email: kdcdenver®kdcarchitects.com \ / / Website: www.kdcarchitects.com 0POSED (2) AT&T PANEL ANTENNAS, 50' SECTOR SEE DETAIL 2,6/A-7. / AT&T WIRELESS SERVICES ROOF \- / \ / / 2101020.003 o \ JHR PROPOSED 4'-0 HIGH \ / WOOD MECHANICAL SCREEN `�oa SEE STRUCTURAL DWGS. O \ / \ \ 1 03.03.00 CLIENT REVIEW/ZONING \ / 2 04.21.00 ZONING /PROPOSED COAX ROUTE ON WALL of �j• / 3 05.31.00 ZONING REVISION PROPOSED HVAC ``�` / 4 06.1900 ZONING REVISION CONDENSERS ON ROOF 5 06.23.00 RF REVISION �- 6 06.27.00 ZONING REVISION PROPOSED (2) AT&T OMNI ANTENNA 07.11.00 OWNER REVISION 10.19.00 CONSTRUCTION/REVISION 9 11.07.00 CONSTRUCTION/REVISION 12.20.00 CONSTRUCTION/REVISION 01.25.01 CONSTRUCTION/REVISION WALL MOUNTED CABLE SUPPORT WITH SHROUD. SEE DETAIL 7/A-7. bc.� / / O / / / ®AII drawings and written material contained �p 1 , herein may not be duplicated used or disclosed ROOF `� + d,, without the written consent of the architect. <11 \ A UPPER LE� ROOF/ ANTENNA FRAME WALL MOUNTED EXISTING TRANSFO ER P POSED ACCESS P EL / / \ SEE DETAIL 6/A-7. WEST VA I L SEE TRUCTURAL D INGS \ / 2077 N. FRONTAGE RD. \ PR ANTE ( 230'AT&T SPAN L / PROPOSED AT&T PANEL VAIL, COLORADO 81657 AI1l2,6/A-7. ANTENNAS, 140' SECTOR EE D SEE DETAIL 2/A-7. a \ PROPOSED AT&T PANEL / ANTENNAS, 140' SECTOR \ LINE OF EXISTING G <2 A / \ WALL BELOW -7 / �G>' gyp. ROOF-TOP ANTENNAS & \ / EQUIPMENT ROOM / o ROOF PLAN 1 SCALE: 1/8" =1'-0" ROOF PLAN 0 yf. o cot K 8 5 -1139 NS�D ARAN\ 24445-7DE-2056—A05-11 r.F O I AT&T AT&T Wireless Services SUITE C-1 100116TH. STREET DENVER, COLORADO 80265-0003 PROPOSED HVAC CONDENSERS ON ROOF PROPOSED 4'-0" HIGH MECHANICAL SCREEN PAINT TO MATCH BLDG. 8 PROPOSED (2) AT&T OMNI ANTENNA PROPOSED (2) AT&T PANEL ANTENNAS, T.O. ROOF 230' SECTOR, PAINT TO MATCH EXISTING BUILDING PROP05ED (2) AT&T PANEL ANTENNAS, T.O. NEW WALL 140' SECTOR, PAINT TO MATCH EXISTING BUILDING EL " . 134—B t PROPOSED (2) AT&T PANEL ANTENNAS, OF ANTENNAS 140' SECTOR, PAINT TO MATCH EXISTING BUILDING — — — — — — — — — — — — EL. 132'-6" t � ■ 1 EXISTING 8" RUSTIC CEDAR SIDING PENTHOUSE LEVEL EL. 124'-8" EXISTING FLUTED CONCRETE 00111 1 ANEW DUMPSTER ENCLOSURE K C UPPER LEVEL Architects — Engineers, PC. A EL 112'-0" y 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 7 F 303.750.6999 FAX 30350.0236 Email: kdcdenver®kdcarchitects.com Website: www.kdcarchitects.com SUITE 'B' ® LOWER LEVEL AT 8c T WIRELESS SERVICE S PROVIDE WINDOW BLINDS 2101020.003 TO MATCH SUITE 'B' JHR 1 SOUTH ELEVATION 1 03.03.00 CLIENT REVIEW ZONING SCALE: 1/8 — 1 0 REVIEW/ ZONING 04.21.00 ZONING 3 05.31.00 ZONING REVISION 4 06.19.00 ZONING REVISION 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION 07.11.00 OWNER REVISION 10.19.00 CONSTRUCTION/REVISION +- 9 11.07.00 CONSTRUCTION/REVISION 12.20.00 CONSTRUCTION/REVISION 01.25.01 CONSTRUCTION/REVISION PROPOSED 4'-0" HIGH 4'-0" MECHANICAL SCREEN PROPOSED (2) AT&T OMNI ANTENNA PROPOSED (2) AT&T OMNI ANTENNA MECPHANICAL SCREEN GH PAINT TO MATCH BLDG. Q PAINT TO MATCH BLDG. PROPOSED WAG PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED HVAC CONDENSERS ON ROOF 23U SECTOR, PAINT TO MATCH EXISTING BUILDING 50' SECTOR, PAINT TO MATCH EXISTING BUILDING CONDENSER ON ROOF m l drawings a d written, mat rial egntain�d herein may no) be duplicate used or disclosed without the written consent of the architect. PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS, 140' SECTOR, PAINT TO MATCH EXISTING BUILDING 140' SECTOR, PAINT TO MATCH EXISTING BUILDING D(19ING 8" RUSTIC WEST VA I L CEDAR SIDING III hill or 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 El ROOF—TOP ANTENNAS 8c ` EXISTING FLUTED CONCRETE------,,,,___," EQUIPMENT R O O M zzzl EXISTING 8" RUSTIC CEDAR SIDING , IN A NEW DUMPSTER ENCLOSURE ELEVATIONS EXISTING FLUTED CONCRETE Oz 0 90 O � h n WEST ELEVATION 3 EAST ELEVATION KE MI '��� 2 SCALE: 1/8" = 1'-0° SCALE: 1/8" = 1'-0" � h B-1139 � �u' "��, 24445-7DE-2056—A06-1 1 i Ole \ /'' \\ AT&T AT&T Wireless Services \ ' \ \ SUITE C-1 EXISTING TRANSFORMER / \ / 1001 16TH. STREET i \\ °/ \\ / DENVER, COLORADO 80265-0003 \ /' \\ / � \\ \ EXISTING RETAINING WALL �' \\\ / / ° - \\\ \\ EXISTING TRANSFORMER \\ \\\ / ° / a � ■ i loll ♦ \ /' \ \ \\ EXISTING BUILDING \ \ / KDC\ > o 0 ♦ \ \ / Architects — Engineers, P.C. 2-5'-0" GATES \ / // 12250 East Iliff Avenue, Suite 302 / \ / Aurora, Colorado 80014-1253 \ \ ° / 303.750.6999 FAX 303.750.0236 \\ / ° /° \ Email- kdcdenver®kdcarchitects cam / \ Website: www.kdcarchitects.com \ \\ \ \\ AT&T WIRELESS SERVICES \ 2101020.003 \ 10'-0" x 8'-0" DUMPSTER ENCLOSURE / \ \ \ \ ' \ / JHR ' 1 03.03.00 CLIENT REVIEW/ZONING ° 2 04.21.00 ZONING ♦ \ 5��� \ .001, / 3 05.31.00 ZONING REVISION / 4 06.19.00 ZONING REVISION \ ° 5 06.23.00 RF REVISION DUMPSTER — 6'-0" W x 6'-8"H x 5'-6" D. ,,6�1 ° 6 06.27.00 ZONING REVISION 1 \ ° 07.11.00 OWNER REVISION 10.19.00 CONSTRUCTION/REVISION 11.07.00 CONSTRUCTION/REVISION / 12.20.00 CONSTRUCTION/REVISION 01.2501 CONSTRUCTION/REVISION / ' ♦ `� / m II drawings arld writton matgrial cpntain�d herein may not be duplicated used or disclosed 9' HIGH CEDAR FENCE W/ (2) 4'-6" GATES. ® \\ '�\\ / / without the written consent of the architect. 6'-0" x 10'-0" CONC. PAD WEST VAIL ♦ ♦ \ \\ 2077 N. FRONTAGE RD. ♦ \ \ \\ VAIL, COLORADO 81657 \ \ \ \ \ \ ROOF—TOP ANTENNAS & EQUIPMENT ROOM \ \ DUMPSTER CORRAL SITE PLAN of co�o� O)TRTIAL SITE PLAN 9 LE- 1/4" = 1'-0" O I K- ' Mfg I� <� t -1139 All IIq 8 Q) �W III , �`SED ARC`S\ 24445-7DE-2056—A08-11 r \\ �A r -` EXISTING TRANSFORMER AT&T AT&T Wireless Services / 2 x 12 RAKE AND EAVE TRIM 2 x 12 RAKE AND EAVE TRIM SUITE 1001 16T6T H. STREET / 12 ® DENVER, COLORADO 80265-0003 4 4 T.O. TRASH CORRAL T.O. TRASH CORRAL / 113'-0" 113'-0" EXISTING BUILDING \ / � 6x6 COLUMN � ■ , 5 T.O. FENCE 109'-0" T.O. FENCE 109'-0" S-3 / / moo, 1x8 LAPPED SIDING / 2X8 CROSS BRACING / INSIDE FACE OF COLUMN / \ / OF EACH WALL \ B.C. SIDING 101'-0" B.O. SIDING 101'—O- rL SLAB 100'-0" " T.O. SLAB 100'-0" K C Architects — Engineers, P.C. 12250 East Iliff Avenue, Suite 302 10'-0" x 8'-0" DUMPSTER ENCLOSURE n EAST ELEVATION WEST ELEVATION Aurora, Colorado 80014-1253 SCALE: 1/4" = 1'—p" SCALE: 1/4" = 1'—O" 303.750.6999 FAX 303.750.0236 �s Email: kdcdenver®kdcarchitects.com Website: www.kdearchitects.com RROPOSED 4" DIA. BOLLARDS (TYP.) n 3 � ` AT&T WIRELESS SERVICES o ` 2101020 003 2x12 RAKE AND EAVE TRIM 10"o `\ T.O. TRASH CORRAL T.O. , /� / 113'—p \ ' 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING DUMPSTER — 6'-0 . x 6'-8'H. x 5'-6" D. 3 05.31.00 ZONING REVISION \ / T.O. GATE 109'-0" 4 06.1900 ZONING REVISION \\ /,/ 5 06.23.00 RF REVISION p, GATES W/ HEAVY DUTY COMMERICAL 6 06.27.00 ZONING REVISION / \ HINGES AND LATCHES 07.11.00 OWNER REVISION 10.19.00 CONSTRUCTION/REVISION 9 11.07.00 CONSTRUCTION/REVISION 12.20.00 CONSTRUCTION/REVISION 01.25.01 CONSTRUCTION/REVISION PQ��o,aLE C - �G►ST�RF 0�Q�', 6x6 COLUMN B.O. SIDING 101'-0" �y M T.O. SLAB 100'-0" * 949 6x6 WOOD COL. (TYP.) 3 SOUTH ELEVATION A m All dr ings an material contained herei may not be d licated used or disclosed \ SCALE: 1/4" = 1'-0" without the written consent of the architect. 9' HIGH FENCE W/ (2) 4'-6" GATES. \ COMP. SHINGLE ROOF WEST VA I L 2077 N. FRONTAGE RD. 6'-0" x 10'-0" CONC. PAD T.O. TRASH CORRAL 11 3'-0" VAIL, COLORADO 81657 \ T.O. FENCE 109'-0" o 4 / ROOF-TOP ANTENNAS & \ \ 2X8 CROSS BRACING \ / INSIDE FACE OF COLUMN EQUIPMENT ROOM OF EACH WALL B.O. SIDING 101'-0" 6x6 COLUMN T.O. SLAB 100'-O" DUMPSTER CORRAL FLOOR PLAN & ELEVATION ELEVATIONS (� NNORTH SCALE: 1/4" = 1'-0" (j� FLLOOR PLAN SCALE: 1/2" = 1'-0" S 13 f 24445-7DE-2056—SO3-9 CONCRETE CAP EXISTING ASPH. PAVING 6" CONC. SLAB 1 4"0 SCHEDULE 40 CARBON STEEL PIPE AT&T Wireless Services F G T FILLED WITH CONCRETE AND PAINTED YELLOW SUITE C-1 _ __ IN ACCORDANCE WITH THE DESIGN AND 1001 16TH STREET ————— i——————————— ————— CONSTRUCTION SPEC. FOR PAINTING. DENVER, COLORADO 80265-0003 • �___ w _ —III=LI=III—II f 1 C° " o III—III=� I �� �I 1=1 I I—III I a 4 , 6X12#1 DF -III—III 1 #4 BARS @16" O.C. EA. WAY �b= e —I I i—I I ° • ° #4 L ® 16" O.C. 6" CONCRETE SLAB P COMP. SHINGLE ROOF ON (2) LAYERS #15 FELT ON 5/8" CDX 2-#4 BARS CON'T � N _Z PLYWOOD W/GALV METAL DRIP EDGE CONCRETE ° S54 - 2x10 @160C #2 HF 18° 6x6 WOOD COLUMN T.0 FENCE & GATE MIN 109 -0" Z 2 x 12 FASCIA 6 X 12 # 1 DF 18" x 24" MONOLITHIC F rG. A BOLLARD DETAIL 2 3 SCALE. 3/4" = V-0" SCALE: N T S Architects — Engineers, P C 12250 East Iliff Avenue, Suite 302 1X8 CEDAR LAPPED Co Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 2x6 STUD 24" Q.C. Email- kdcdenver @kdcarchitects com EACH WALL Website, www.kdcarchitects.com 2X8 CROSS BRACING INSIDE FACE oxx 18"x24" DP CONC MONOLITHIC FTG OF COLUMN OF EACH WALL ^ GATE 3 COMPOSITION SHINGLE ROOF S-4 ON 2 PLY 15# ROOFING - AT&T WIRELESS SERVICES 6X6 #2 HF COLUMN @ CORNER FELT PROJECT NUMBER 5/8" CDX PLYWOOD 2101020 003 2-2x8 — --o-- — — { 1 ROOF DECK W/PLYCUPS @ 16" 0 C - METAL POST BASE AND CAP (SIMPSON-STRONG TIE PBS66) B 0. SIDING 6" CONC SLAB W/ #4 BARS I I RAFTERS LOFK EACH WEND 101'-0" @ 16" 0 C EA. WAY GALV. MTL JHR T 0. SLAB I i DRIP EDGE ISSUE 100'-0" I I o � � I I 1 0303.00 CLIENT REVIEW/ZONING I I 11 2 0421 00 ZONING 3 0531.00 ZONING REVISION I 4 061900 ZONING REVISION 6" CONC SLAB W/ #4 BARS I 2X10 RAFTER @ 1 S 06.23.00 RF REVISION O 16" O.0 EA WAY I I O.C., #2 HF 6 p7 ZONING 11 00 OWNER REVISION L — — — — — — — J 8 101900 CONSTRUCTION/REVISION 9 11.0700 CONSTRUCTION/REVISION RS CEDAR 2X12 FASCIA 12.2000 CONSTRUCTION/REVISION 18"x18" CONC MONOLITHIC FTG 2 6X12 # 1 DF BEAM 012501 CONSTRUCTION/REVISION 10'-0" �Q¢ ��G►sreRF�R2� 6X6 #2 HF COL (BEYOND) r 1X8 CEDAR LAPPED SIDING a 949 y qTF °^� �NAOO X210" � I ox oV0 SHED SECTION A 4 FOUNDATION PLAN 0 5 EAVE DETAIL A ® AII drawings and written material contained 1 herein may not be duplicated used or disclosed without the written consent of the architect SCALE. 1/2" = V-0" SCALE: 1/4" = V-0" SCALE.1-1/2" = V-0" ® ° GENERAL NOTES: WEST VAI L 1. USE APPROPRIATE STRUCTURAL CONNECTION HARDWARE EQUIVALENT TO SIMPSON-STRONGTIE 2077 N. FRONTAGE RD.' CONNECTORS VAIL, COLORADO 81657 2. SUBMIT SHOP DRAWINGS, CUT SHEETS, OR CATALOG DATA FOR REVIEW. 10'-0" `\j 6X12 #1 DF BEAM 2X10 RAFTER @ 16" (MAX ) ROOF-TOP ANTENNAS & 0 C #2 HF EQUIPMENT ROOM SHEET TITLE — 6X12 #1 DF BEAM— I DUMPSTER CORRAL 6X6 # 2 HF FOUNDATION PLAN, COL. (TYP.) BLDG. SECTION & DTLS. NUMBER ISHEET 6 ROOF FRAMINGPLAN A GENERAL NOTES 8 NOT USED 9 NOT USED SCALE:1/4" = V-0" SCALE N T.S SCALE. N T.S. SCALE. N T S 24445-7DE-2056— 504-11 J WIR SS S RVIC S SITE NO . - .- All: WEST V L AT&T Wireless Services SUITE C-1 1001 16TH. STREET Alm&l AT&7 2077 N . FRONTAGE R DENVER, COLORADO 80265-0003 VAIL, COLORADO 81657 I ROOFiiiiiiiiiiiiii "TOP ANTENNAS AND EQUIPMENT ROOM ® ® ' PROJECT TEAM PROJECT SUMMARY DRAWING INDEX SYMBOLS PROPERTY, OWNER SITE ADDRESS TITLE SHEET __ __ i PROPERTY LINE , JAYNE BRANDESS REVOCABLE TRUST 2077 N. FRONTAGE RD. T-1 TITLE SHEET XC X X X X FENCING 41184 HWY 6 VAIL, COLORADO 81657 ARCHITECTURAL —E E E— ELECTRICAL SERVICE AVON, CO 81620 HOME PHONE: NA WORK PHONE: (970) 949-1636 A-1 SITE PLAN —T —T—T— TELCO SERVICE IDC CONTACT: BRIAN O'REILLY CODE BLOCK A-2 FIRST FLOOR PLAN -+ A-3 EQUIPMENT ROOM AND DEMOLITION PLAN (N) NEW Architects - Engineers, PC. AP P LI CANT SITE LOCATION: 2077 N. FRONTAGE RD. 4; 12250 East Iliff Avenue, Suite 302 ' VAIL, COLORADO 816571, .. (E) EXISTING ;, Aurora, Colorado 80014-1253 A-4 CONSTRUCTION, FINISH, AND CEILING PLANS 303.750.6999 FAX 303.750.0236 AT&T WIRELESS SERVICES Email, kdcdenver®kdcarchitects com SUITE C-1 JURISDICTION: TOWN OF VAIL A-5 ROOF PLAN XXX Website: www.kdcarchitects.com DETAIL REFERENCE SYMBOL 1001 16TH. STREET 75 S. FRONTAGE RD. DENVER, COLORADO 80265 VAIL, CO. 81657 A-6 ELEVATIONS A-3 (303) 573-3277 (970) 479-2100 AT&T WIRELESS SERVICES CONTACT: JEFFREY W. RINEHART A-7 ARCHITECTURAL DETAILS 1 - A_2 ELEVATION REFERENCE SYMBOL BUILDING CODE: 1997 UNIFORM BUILDING CODE MECHANICAL 204033.003 APPLICANT AGENT 1996 NATIONAL ELECTRIC CODE t PROPOSED EQUIPMENT OCCUPANCY: )K- -/�, M-1 MECHANICAL DETAILS, NOTES AND SCHEDULES A22 }{ ' ' UNMANNED TELEPHONE EQUIPMENT AND ANTENNA � 0 PLAN REFERENCE SYMBOL WALKER COMMERCIAL ( ) M-2 MECHANICAL PLAN BW X; 7354 S. EAGLE ST. ENGLEWOOD, CO. 80112 WATER SUPPLY: NONE/WASTE WATER: NONE/PLUMBING: NONE ELECTRICAL 0 KEYED NOTES MKS TEL: (303) 680-6600 ` �l ,�'• ° 7� w , FAX: (303) 73#52' W Z� ELECTRICAL: PUBLIC SERVICES E-1 ELECTRICAL SPECS, NOTES, SYMBOLS, ABBREVIATIONS, AND ELECTRICAL SITE PLAN !� � CELL: (303) 905-4444 TELEPHONE: U S WEST ® GROUND ROD WITH ACCESS 1 03.03.00 CLIENT REVIEW/ZONING CONTACT: RALPH WALKER E-2 DEMOLITION PLAN 2 04.21.00 ZONING THE PROPOSED PROJECT INCLUDES E-3 POWER LIGHTING GROUNDING PLANS AND NOTES ® XIT GROUND ROD 3 05.31.00 ZONING REVISION 4 06.1900 ZONING REVISION CONSTRUCTION MANAGER PROVIDE AT&T EQUIPMENT ROOM IN EXISTTNG BUILDING. E-4 ONE-LINE DIAGRAM, PANEL SCHEDULE AND NOTES ® GROUND ROD 6 06.27.00 ZONING RIEVISION CONSTRUCTION TO BE ONE HOUR RATED. AT&T WIRELESS SERVICES E-5 DETAILS AND DIAGRAMS DISCONNECT SWITCH �s SUITE C-1 C040 INSTALLATION OF AT&T ANTENNAS ON ROOFTOP. E-6 DETAILS � � o�� 1001 16TH. STREET METER ON METER/ BREAKER UNIT /'�� �Q DENVER, COLORADO 80265 • 3 SECTORS/ 4 ANTENNA PER SECTOR 12 TOTAL; 1 OMNI ANTENNA; E-7 DETAILS . (303) 881-7386 / � �K CONTACT: DON WILL CIRCUIT BREAKER AMP COAXIAL CABLE RUNS FROM ANTENNAS TO EQUIPMENT ROOM; A P ARC H ITECT / ENGINEER A NEW TELEPHONE SERVICE RUN TO THE EQUIPMENT ROOM; GEN GENERATOR i � �s � ,gyp ARG • KDC ARCHITECTS.ENGINEERS, P.C. A NEW 400A ELECTRICAL SERVICE TO THE EQUIPMENT ROOM; 12250 E. ILIFF AVE. SUITE 302 CADWELD TYPE CONNECTION 0 1 drawings ar�d written mat vial contained AURORA, COLORADO 80014 AT&T PROJECT AREA IS APPROXIMATELY 960 SQUARE FEET. herein may not be duplicated used or disclosed ® without the written consent o the architect. (303) 750-6999 COMPRESSION TYPE CONNECTION (303) 750-0236 FAX ken.camp @kdcarchitects.com LAT 39'37'59.2"N s CONTACT: KENNETH D. CAMP LONG 106'24'48.8"W -- -- ---- - GROUND WIRE ' WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 LEASE , AREA DESCRIPTION APPROVALS VICINITY MAP NO SCALE DIRECTIONS TO SITE " SITE PARCEL NO.: TAKE 1-70 WEST TO VAIL, TAKE WEST VAIL EXIT #173, PROCEED EAST SITE NAME: WEST VAIL Ra�_9D PAST CITY MARKET TO BRANDESS BUILDING AT 2077 N. FRONTAGE RD. WEST. e LEGAL DESCRIPTION: AT&T APPROVAL FF��G LEGAL DESCRIPTION - ENTIRE PARCEL �� F' LOT 39, RESUBDIVISION OF BUFFER CREEK, COUNTY OF EAGLE, DATE �, '` ROOF—TOP ANTENNAS STATE OF OF COLORADO, PARCEL NO pis REV OF, PROJECT s' REAL ESTATE APPROVAL EQUIPMENT ROOM NO. 1 70-2(7)1B3,ACCORDING TO CIVIL ACTION NO. 1481 IN THE E. �/ C DISTRICT COURT IN AND FOR THE COUNTY OF EAGLE, DATE 0� 70 V -ry STATE OF COLORADO. CONSTRUCTION AP P R OVAL Sir ' ; SHEET, TITLE • / Iv SITE1r� R F APPROVAL DATE ® .- �,�.� CE COPY TITLE SHEET LANDLORD APPROVAL DATE EQUIPMENT ENGINEER APPROVAL DATE NORTH � . DATE NT5 ' DWG. NAME:T1.DWG DATE: 5/19/00 2.40 PM AN ONE= Mon AT&T 3 / 110, AT&T Wireless Services / /,/ �� SUITE C-1 1001 1TH. STREET DENVER, COLORADO 80265-0003 / \ \ \ / 'e, \ \ / /// / \ \ loo, / \ \ \ \ '" / // / OP q /' 1 RIZI o Poi / ` `\ `� PED KD%am; / T Architects — Engineers, P.C. / / \ / // '' \ 12250 East Iliff Avenue, Suite 302 •' \ 'A Aurora, Colorado 80014-1253 �J / \ / �,'e \ \ 303.750.6999 FAX 303.750.0236 BOO/ / / \ / / �j \ \ Email: kdcdenverC�kdcarchitects com 100,// , / ' ,s, \\ a Website: www.kdcarchitects.com 5 / / \ /' ' ' - '��`s ` SERVICES 1100'loll ,�o \ \\ AT&T WIRELESS / CPO / / DRAWN/ ,� GP \ 204033 003 �� , � �\ �' / '/ / \ \\ a, BMW CHECKED BYI � \ \ \\ i \ ' ' 9QP sr MKS • / ,� � � / 2x3.3 INLET / / / \ \ / \ \ S/ 1t9 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING �\ \ /' \ �/ �QPG� �O�'F" 3 05.31.00 ZONING REVISION ooe\ RIS �� �.� STAIRWELL � o��, 4 0619.00 ZONING REVISION N / / IS 6 06.27.00 ZONING REVISION oell WV ' O� O� C040 1 DUMP ER V\ 6 HIGH CEDAR FENC P��` N DUMPSTER, ENCLOSUR os, sr, \ �`` \V rc�'C� Q / AMP W/ DBL. 12' GATE \ ',�\� \ Q �O v`` •5c, / �o C SED ARG��°"� 0 All drawings and written material contained herein may not be duplicated used or disclosed \ without the written consent of the architect. jo, \ FH SITE INFORMATION WEST VAIL 6 c�Re F, 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 OJY �v PLATTED � 0 0°03'13" . R= 5910.00' ROOF—TOP ANTENNAS & L= 5.53' EQUIPMENT ROOM CHD= S47°21 '1 5"W P&M= f 5.53 N37°1 5'30"W SHEET! TITLE MEASURED 0.90' = 00°01 '31 " R= 5910.00' L= 2.61 ' SITE PLAN F CHD= S47°02'03"W 2.61 ' SITEPLAN SCALE: 1"=15'—O" " DWG. NAME: A1.dw DATE: 5/19/00 2:40 PM AT&T AT&T Wireless Services SUITE C-1 1001 16TH. STREET DENVER, COLORADO SD265-0003 Ooe a 3e, I ,r '-3 . Architects — Engineers, PC. R `=P 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-12 303.750.6999 FAX 303.750..00 236 Email: kdcdenvergkdcarchitects com Website: www.kdcarchitects.com I EXISTING WALLS TO 1 2 3 I 4 5 6 7 8 9 10 x AT&T WIRELESS SERVICES BE REMOVED D 20403 ! - A BMW EXISTING TRANSFORMER I 0 MKS I I RMUMMUMN PROPOSED AT&T • � � ! c EQUIPMENT ROOM I I I I 1 03.03.00 CLIENT REVIEW/ZONING ° ! SUITE B I STORAGE I I 2 04.21.00 ZONING SUITE A BRANDESS RETAIL AND PROFESSIONAL BUILDING 3 05.31.00 ZONING REVISION 4 06.19.00 ZONING REVISION X® 12 t-0 a ®X ! 5 06.23.00 RF REVISION t ■ 5-6 6 06.27.00 ZONING REVISION DUMP5IER I_t C dK co E IF ___ - - - - -- ___ - - - - - ii 6' HIGH CEDAR FENCE/ C ,�4, c): C040 DUMPSTER ENCLOSURE O W/DBL. 12' GATES — K CAMP ! I ELECTRICAL I I I ! ! I B_1 139 I I �NSED ARG EXISTING BEAM ®All drawings and written material contained FURRED OUT I EXISTING CONCRETE SIDEWALK herein may not be duplicated used or disclosed without the written consent of the architect. t. � ttt� � tttttttttttttt� tttttttttttttt� � � t� �� :r • - • EXISTING COLUM WEST VAIL ! ! I I I I ! A - - - - - - - - 2077 N. FRONTAGE RD. PROPOSED WALL 1 HR RATED VAIL, COLORADO 8 657 s CONSTRUCTION ROOF—TOP ANTENNAS 8c ( EXISTING CMU WALLS � EQUIPMENT ROOM SHEET-TITLE,, I EXISTING PARKING FIRST FLOOR PLAN I r NUMBER ' 1 FIRST FLOOR PLAN • SCALE: 3116 1 0 DWG. NAME: A2.dw DATE: 5/19/00 2:40 PM i INSTALLATION KEYED NOTES M or 0 PROVIDE AND INSTALL VERTICAL CHASE. REFER TO 7/A-7 12" MAXIMUM 1'-0" FINISHED Al 4'-0" O A/C UNITS—SEE MECH DWGS 3'-0" 2'-0" BLOCKING BETWEEN STUDS AT&T Wireless Services 03 PROVIDE AND INSTALL EXHAUST FAN AND DUCT AS PER MECH DWGS. BEHIND GYP BOARD SUITE C-1 4" MINIMUM 1001 16TH. STREET ® PROVIDE AND INSTALL EXTERIOR WALL MOUNTED GENERATOR PLUG. TYPICAL DENVER, COLORADO 80265-0003 0 PROVIDE & INSTALL WAVEGUIDE PLATES & PORTS FOR COAX CABLE a PENETRATION THRU WALL REFER TO DETAIL 1/A-7. ® c � ■ 15© PROVIDE & INSTALL 3-5/8" METAL STUDS W/ 5/8" GYP. BD. EACH SIDE. c FINISHED FLOOR o 0 REFER TO DETAIL 9/A-6. (TYPICAL) i O7CV PROVIDE 3' X 6'-8" H.C. WOOD DOOR JAMS W/ LEVER HANDLE HARDWARE. N FACE OF WALL N ® PROVIDE STAINLESS STEEL GRAB BAR, SEE 1/A-3. (TYPICAL) if 0 INSTALL NEW 3'-6" X 7'-4" X 4" CONCRETE PAD FOR CONDENSER UNITS. WATERNCLOSET GRAB BAR WATERNCLOSET GRAB BAR Cz M a ® EXISTING WINDOWS TO BE BLOCKED WITH NEW WALL HANDY—CAPPED GRAB BAR DETAIL SCALE: N.T 5 K: KDC Architects — Engineers, P.C. DEMO KEYED NOTES] Aurora,East lad Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 10 WALLS AND DOORS TO BE REMOVED Email: kdcdenver®kdcarchitects corn Website: www.kdcarchitects.com Q REMOVE AND RELOCATE ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL DEMOLITION. 0 EXISTING DOOR TO REMAIN AT&T WIRELESS SERVICES PROJECT 204033 003 q 3 CHECKED 1 2 3 a MKS GEN FUTURE o 5 + PLUG EQUIP 1 03.03.00 CLIENT REVIEW/ZONING D 2 04.21.00 ZONING 3 05.31.00 ZONING REVISION III I I I I I 4 06.19.00 ZONING REVISION RESTRO M T 2 5 06.23.00 RF REVISION O I I I I 6 06.27.00 ZONING REVISION X-FMR EXISTING 8" 8 CMU WALL . " -1 I J �-J--I ` I I I I I -o i I Z Q I � I I I I I L U `� LL=- -- -J L- �J;� � m I L NVT p _ �� �� CAMP E r � _> -119 �B' I Z �- -� SUITE A I r SUITE A �� l o� CD METER & I N I I AT&T �- I STORAGE I AT&T i � t� 3 O SERVICE I� I SUITE B I / / EQUIPMENT ,� S�� ARC ENTRANCE I 6 o U L EQUIPMENT N N ROOM L N L- ROOM w vl I - -- - _-----__--__- A-s I � I - I I SUITE B m All drawings a d written mat vial contained SUITE A 5� L J SUITE A herein may not be duplicated used or disclosed W FU I II without the written consent o the architect. x X---MX x—x�X I % I INFORMATION 12,_0„ 51_6PF W 5 _6 EL 1 -LF I � III � WEST� VAIL x x I � _ IT CD l I cn r�7 DUMPSTER i I $I� i I —I — — — —I — - -- I 2077 N. FRONTAGE RD. x 00 ' c - - - - -�- - - Way -I- _ - - - - - - - - — c - - - - -1 �—______=_=_ - - - - VAIL, COLORADO 81657 EXISTING COLUMN I I Km x Q EXISTING BEAM FURRED OUT�� - - B —�-}— 14'-7" LL Uj m ELECTRICAL I FT -- -, 6 ,Ile ROOF—TOP ANTENNAS 8c EQUIPMENT ROOM ALARM I I I I 3 I I 4 7i xy c EQUIP RM- 1ST FLR I :4 AND DEMO PLAN . . (:�)50U1PMENT ROOM — FIRST FLOOR SCALE. 1/4" = 1'-0" DEMO PLAN SCALE: 1/4- = 1'-0" DWG. NAME: A3.dw DATE: 5/19/00 2:40 PM INSTALLATION PLAN KEYED NOTES 1CONSTRUCTION PLAN GENERAL NOTES FINISH SCHEDULE KEYED NOTES REFLECTED CEILING GENERAL NOTES ' ..�.� i H 1O RADIO EQUIPMENT PROVIDED AND INSTALLED BY OTHERS (SHOWN FOR COORDINATION PURPOSES) 1. THE FACILITY IS AN UNOCCUPIED TELEPHONE EQUIPMENT FACILITY. 1O EXISTING WALLS-FINISHED: NO MODIFICATION REQUIRED. NEW WALL (1) PRIME; (2) COATS OF PAINT. COLOR P-1 P.P.G. #2761 FLINTSTONE 1. THIS DRAWING IS FOR COORDINATION PURPOSES ONLY, REFER TO MECHANICAL A RADIO RACKS AND ELECTRICAL PLANS FOR SPECIFIC INFORMATION. B RECTIFIERS 2• THE NET AREA OF THE EQUIPMENT ROOM IS APPROX. 276 SQUARE FEET. AT&T B CLOSED-CELL BATTERIES (NON-GASSING TYPE) O RUBBER BASE: ARMSTRONG-CHARCOAL GREY #14123, 4" COVE 2. FIXTURE AND EQUIPMENT ELEVATIONS ARE AS MEASURED FROM EXISTING WALL. O18" WIDE CABLE LADDERS 7'-4" A.F.F. SUSPENDED FROM STRUCTURE. 3. THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK. 2 { ) USING BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLEY REFER TO DETAILS 4 & 5 A-6. BY OTHERS RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, O RESILIENT FLOORING: TARKETT "CONCERT ARTFLEC" AT&T Wireless Services OHIGH LOW TEMPERATURE ALARMS ADJACENT TO ENVIRONMENTAL SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF VCT-2 #2221 OFF WHITE SOLO SUITE C-1 CONTROL PANEL. SEE MECHANICAL DRAWINGS AND ALARM PANEL SCHEMATIC. THE WORK UNDER THE CONTRACT. 1001 16TH. STREET / '�= O GROUND BAR 4. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS 4 A/C UNITS & ASSOCIATED PIPING: INTERIOR PAINT P-2 REFLECTED CEILING KEYED NOTE$�] ���� DENVER, COLORADO 80265-0003 THAN 2—A OR 2—A1 0BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS EXTERIOR PAINT TO MATCH EXISTING O 13 TELEPHONE BACKBOARD 4' x ' x 3/4" TYPE "CD" FIRE RETARDENT TREATED OF THE PROJECT AREA DURING CONSTRUCTION. PLYWOOD. MOUNT VERTICALLY WITH BOTTOM 4" ABOVE RUBBER BASE. COVER 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE SITE 1O EXISTING CEILING TO REMAIN RELOCATE LIGHT FIXRURES AS REQUIRED AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE FRONT FACE WITH "FRP" FIBERGLASS REINFORCED PLASTIC PANEL. COLOR- WHITE. STARTING ANY WORK. TO ACCOMMODATE NEW CABLE TRAY LAYOUT. %. O SURGE ARRESTOR. SEE ELECTRICAL DRAWINGS. 6. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, O 2'x4' LAY-IN CLG. ® 9'-0" A.F.F. RUBISH AND REMOVE EQUIPMENTNOT SPECIFIED AS REMAINING ON PROPERTY. O POWER FAILURE RELAY. SEE ELECTRICAL DRAWINGS. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, O GYP. BOARD CEILING. OR SMUDGES OF ANY NATURE. O 200 AMP PANEL. SEE ELECTRICAL DRAWINGS. O COORDINATE LOCATION OF THE FOLLOWING W/ FINAL AT&T EQUIPMENT FLOOR PLANS. OENVIRONMENTAL CONTROL PANEL. SEE MECHANICAL DRAWINGS. — LIGHT FIXTURES WALL TYPES oEXTERNAL ALARM PANEL. SEE ELECTRICAL DRAWINGS. - SPRINKLER HEADS Y FLOOR MOUNTED AIR CONDITIONING UNIT. REFER TO MECHANICAL DRAWINGS. EXISTING WALLS - DUPLEX OUTLETS <S> WAVEGUIDE ENTRY PLATE. MICROFLECT CUSTOM 12 PORT THROUGH WALL - THERMOSTAT SEE ARCHITECTURAL DETAILS 1,2,/A-7. ROUTE COAX VERTICALLY AS PER DTL. 7/A7. NEW METAL STUD GYPSUM BOARD WALLS <S> MANUAL TRANSFER SWITCH. SEE ELECTRICAL DRAWINGS. O PROVIDE KEYLESS PORCELAIN FIXTURE W/ 24V DC LAMP FOR EMERGENCY LIGHTING <S> INSTALL VINYL COMPOSITE FLOOR TILE AS PER FINISH SCHEDULE AND MANUFACTURER'S (TYP. OF 6). CONNECT TO 24V DC RECTIFIER / CIRCUIT BREAKER AND PROVIDE INSTRUCTIONS SWITCH BY DOOR SO THAT LIGHTING FIXTURE IS NORMALLY SWITCHED ON BY TECHNICAN DURING POWER OUTAGE ONLY. KDC <S> PROVIDE 4" RUBBER COVE BASE AS PER FINISH SCHEDULE. INSTALL ON ALL NEW Architects — Engineers, PC. AND EXISTING WALLS OF AT&T LEASE AREA. O 2' x 4' FLUOR. LAY—IN FIXTURE '� 12250 East Iliff Avenue, Suite 302 16 INSTALL NEW CONDENSER UNITS ON PAD AS SHOWN. REFER TO MECHANICAL O Aurora, Colorado 80014-1253 AND ARCHITECTURAL DRAWINGS. SMOKE DETECTOR. 303.750.6999 FAX 303.750.0236 Email: kdcdenver®kdcarchitects com -�y O PORTABLE FIRE EXTINGUISHER. PROVIDE ONE (1) 20 LB. CO2 UNIT AND WALL BRACKET. Website: www.kdcarchitects.com <S> NOT USED. < 19 > FUTURE ELECTRICAL EQUIPMENT. AT&T WIRELESS S ERVI CE S REFLECTED CEILING LEGEND . - . NUMBER PROVIDE AND INSTALL EXHAUST FAN. REFER TO MECHANICAL DRAWINGS. 204033 003 HOMOsky O CONSTRUCT METAL STUD DRYVIT VERTICAL CHASE FROM WAVEGUIDE PORT TO ROOF. 2' X 4' LIGHT FIXTURE (NEW) SMT REFER TO DETAIL 6/A6. TAPE & BED TO MATCH ADJACENT SURFACE. O NOT USED O KEYLESS 24V DC SURFACE MOUNT FIXTURE ■ MKS <9> PROVIDE AND INSTALL A CONTINUOUS 2x8 AROUND PERIMETER OF ROOM ® SMOKE DETECTORy s s FOR CABLE TRAY. r, <9> TELCO ENTRANCE BOX BY OTHERS ® EXHAUST FAN REVIEW/ ZONING ,,�, 1 03.03.00 CLIENT REVIEW ZONING 2 04.21.00 ZONING 3 05.31.00 ZONING REVISION 4 06.19.00 ZONING REVISION 5 06.23.00 RF REVISION 20 2 6 06.27.00 ZONING REVISION 16 16 GEN 6 5 COI a PUG 12 1 3 (TYP.) (TYP.) A-7 .Y �r KE" CAMP B-1 139 S^ Nib a 2 11 i N� 1 3 4 �i k4lao100 s ANEL/ o N❑ SUR AR. _ • I I I m All drawings and written material contained o herein may not be duplicated used or disclosed TRANS without the written consent of the architect. LL CT. CAB SW 13 DISC M i `� SERVICE U 1 q 2 3 7 �. * ■ • METER & 5W ENTRANCE U 15 N� � WEST VAI L FTURE 19 EQUIP i TIF UTURE w �. I I 2077 N. FRONTAGE RD. EQUIP 3 W aN I I I I I VAIL, COLORADO 81 657 � I9 ANEL 7 a� 1 4= RELAY 4 EXT U oo ALARM a En 11 — — ROOF—TOP ANTENNAS 8c U 4 =-- EQUIPMENT ROOM �-1-T— — — 5 23 5 I I I I � TELCO A-7 BD. ' CONSTRUCTION, FINISH, 15 AND CEILING PLANS MQ SHIEET k 1 FlUMBER 17 4 FINISH PLAN REFLECTED CEILING PLAN (1 INSTALLATION PLAN SCALE: 1/4" _ ,'-0" SCALE: 1/4" _ ,'—o" #r:, SCALE: 1/4" 1'-0" 0 4' 8' 12' 0 4' 8' 12' 0 4' 8' 12' SCALE FEET SCALE FEET SCALE FEET DWG. NAME:A4.DWG DATE: 5/19/00 2:40 PM AT&T AT&T Wireless Services SUITE C-1 �0 1001 16TH. STREET DENVER, COLORADO 80265-0003 KDC 0 I f i Architects — Engineers, P C \ / / \ 12250 East Iliff Avenue, Suite 302 / / / / Aurora, Colorado 80014-1253 PROPERTY LINE O \ f 303.750.6999 FAX 303.750.0236 Email: kdcdenverUkdcarchitects.com Ile / Website: www.kdcarchitects.com \ / / / \ \ 1001, \ AT&T WIRELESS SERVICES \ ROOF / . . •l000l / PROPOSED (2) AT&T PANEL O / 204033 003 \ / ANTENNAS, 50' SECTOR \ / 2 6 \ / j / / \ / A-7 A-7 \ / / Emrs C V / \ MKS \ / / / / • • O1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING ZPROPOSEDOUTE ON WALL \ / / j 3 05.31.00 ZONING REVISION \ / / \ n' 4 06.19.00 ZONING REVISION / / \ PROPOSED (2) AT&T OMN TEN N4 5 06.23.00 RF REVISION PROPOSED (2) AT&T PANEL \�4 \ 6 06.27.00 ZONING REVISION ANTENNAS, 230' SECTOR / \� / / / o / , �._..,,,a mob., o �� �. o� o A-7 A-7 WALL MOUNTED CABLE SUPPORT NP, \ \ / / WITH SHROUD / \ / �� � °1 � O + \ UPPER LEVEL \ / CAMP A-7 \ ROOF / / �� 1o13b�0 / / \ / } / \ / m All drawings and written material contained / \ herein may not be duplicated used or disclosed / \ 1 \ / without the written consent of the architect. r / Q \ / / / WALLNMO NTEDE ANTE / • • A-7 \ \ EXISTING TRANSFORMER \ / \ / \ / WEST VAIL ROOF / / ,y0 PROPOSED AT&T PANEL O ,r 2077 N. FRONTAGE RD. olool ANTENNAS, 140 SECTOR A-7 VAIL, COLORADO 81 657 LINE OF EXISTING / \ WALL BELOW DUMPSTER / ROOF—TOP ANTENNAS 8c 6 HIGH CEDAR FENCE/ \ \ y p.. EQUIPMENT ROOM DUMPSTER ENCLOSURE / r W/D9L. 12 GATES \ \ \ �• l 4Y (��ROPLAN OF cALE: 1/8° =1'-0° ROOF PLAN NUMBER SHEET Y PROPOSED AT&T PANEL ANTENNAS, 140' SECTOR A 5 A-7 DWG. NAME: A5.dwg DATE: 5/19/00 2:40 PM N Mon AT&T E PROPOSED (2) AT&T OMNI ANTENNA ' AT&T Wireless Services SUITE C-1 PROPOSED (2) AT&T PANEL ANTENNAS, 1001 16TH. STREET 140' SECTOR, PAINT TO MATCH EXISTING BUILDING DENVER, COLORADO 80265-0003 PROPOSED (2) AT&T PANEL ANTENNAS, 14V SECTOR, PAINT TO MATCH EXISTING BUILDING PROPOSED (2) AT&T PANEL ANTENNAS, ® �� 230' SECTOR, PAINT TO MATCH EXISTING BUILDING A T.O. ROOF xk T.O. NEW WALL EL. 134'-8" _ OF ANTENNAS EXISTING 8" RUSTIC EL. 132'-6" CEDAR SIDING PENTHOUSE LEVEL EL. 124'-8" EXISTING FLUTED CONCRETE KDC UPPER LEVEL � EL. 112'-0" Architects — Engineers, P C 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 i� 303.750.fi999 FAX 303.750.0236 Email: kdcdenver®kdcarchitects com EEIWebsite: www.kdcarchitects.com ® LOWER LEVEL 00'—U" ATBcT UUIRELESS SERVICES i; . . • • �i F 204033 003 S DRAWN : J BW �ECKIED� ISSUE SOUTH ELEVATION MS. • � � j " � " s 1 03.03.00 CLIENT REVIEW/ZONING SCALE: 1/8 = 1'-0" 2 04.21.00 ZONING 3 05.31 AO ZONING REVISION i 4 0619.00 ZONING REVISION 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION PROPOSED (2) AT&T OMNI ANTENNA "fit �, ()V C040� �P 90 K I A j5 [3.1139 PROPOSED (2) AT&T PANEL PROPOSED (2) AT&T OMNI ANTENNA ANTENNAS,270' SECTOR FD, A°R PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS . _ 230- SECTOR, PAINT TO MATCH EXISTING BUILDING 50' SECTOR, PAINT TO MATCH EXISTING BUILDING ®All drawings and written material contained herein may not be duplicated used or disclosed without the written consent of the architect. PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS, - 140' SECTOR, PAINT TO MATCH EXISTING BUILDING 140' SECTOR, PAINT TO MATCH EXISTING BUILDING EEEEEIF EXISTING 8" RUSTIC WEST VA I L CEDAR SIDING 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 r✓ 4 .r ROOF-TOP ANTENNAS EXISTING FLUTED CONCRETE EQUIPMENT ROOM EXISTING B" RUSTIC CEDAR SIDING ELEVATIONS EXISTING FLUTED CONCRETE SHEETNUMBER .s r' r� WEST ELEVATION 3 EAST "ELEVATION SCALE. 1/8 = 1 —0 DWG. NAME: A6.dw DATE: 5/19/00 2:40 PM t %1 i PROVIDE AND INSTALL MICROFLECT DUPLEX sw+1900 18" CABLE LADDER 81334-12 WAVEGUIDE AT WALL [ PENETRATION SET IN BED ALPHA OF SEALANT (MICROFLECT RXO/TX1 850 xmit 81177 OR 8195) 1 HR. RATED EXISTING WALL RXO/TX1 P` 1900 xmit RXO/TX1 RX1/TX4P 1900 xmit (if needed) RX1/TX6 RX1/TX4 850 xmit {; RX0/TX1 P PIPE OR CONDUIT EXISTING ROOF OR WALL BSA AT&T Wireless Services RX1 TX6P ALPHA RXO/TX2 850 xmit SUITE C-1 GAMMA RXO/TXP2P 1900 xmit PIPE SLEEVE -i. RX1/TX5P 1900 xmit (if needed) 1 16TH. STREET DENVER, COLORADO 80265-0003 AT&T RXO/TX3P RX1/TX4P RX1/TX5 850 xmit �y RX1 X4 N GAMMA I< 28 1/2" RXO/TX3 RXO/TX3 850 xmit iy RXO/TX3P 1900 xmit RX1/TX5 RX1/TX5P RXO/TX2P RXO/TX2 RX1/TX6P 1900 xmit (if needed) FILL SPACE Lj BETA RX1/TX6 850 xmit WITH CAULK PLUS W9 1/2' GROUT ALL VOIDS ® , AROUND SLEEVE . 0 0 0 0 o INSTALL A 4" WAVEGUIDE BOOT (TYP.) ASSEMBLY AT OPENINGS USED INSTALLER INSIDE VIEW FOR COMMUNICATION CABLES OR 0 0 A SEALING CAP AT SPARE OPENINGS. RXO/TX1 RX0/1 RX1 X4P RX1/TX4 CORNER SUPPORT In M I AS SHOWN ` N r PROVIDE B1118 WAVEGUIDE 0 LO ENTRY PLATE BY MICROFLECT RXO/TX2 RXO/TX2P RX1 X5P(75 N NOTE: v o o o o (SET IN BED OF MASTIC SEALANT REQUIRED DIRECTLY TO BUILDING SKIN) PIPE MOVEMNTETHRU PENETRATI N. CABLES WITHIN NOTE: SCHEMATIC SAMPLE LADDER SYSTEM • • • • CAULK ENTIRE PERIMETER WITH RXD/TX3 RXO/TX3P 7P(71 CONDUIT PENETRATION SHALL BE APPROPRIATELY 1 HR RATED SEALANT. SEALED AFTER INSTALLATION. O O O O O PIPING/CONDUIT WALL PENETRATION COAX SUPPORT LADDER T—CONNECTION 1 COAX ENTRY BOOT AT EXTERIOR WALL 2 COAX COLOR CODE 3 4 DC Architects - Engineers, PC SCALE N.T.S. SCALE. N.T.S. SCALE: N.T.S. SCALE: NJ S. 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 ?` 303.750.6999 FAX 303.750.0236 .` Email: kdcdenver®kdcarchitects.com 2 ALUMINUM SHROUD Website: www.kdcarchitects.com 1 , 2 X 8 BAND CONTINUED F- RUNWAY END = 3/87j/ AT&T WIRELESS SERVICES SUPPORT (SB-163) ,--- 3/8"Ox6'• LAG BOLT 3 TYP PROJECT NUMBER o � 204033.003 U LO TIRE DP MICROFLECT #1592 X 71 Wim o WALL MOUNT w ° MKS 'd EXISTING FRAME WALL r SB-165 AT&T PANEL > 1 03.03.00 CLIENT REVIEW/ZONING ANTENNA 2 04.21.00 ZONING 3 05.31.00 ZONING REVISION 3-2x6 W/1/2' PLYWD. " 4 06.1900 ZONING REVISION �—SPACERS 6 6 5 06.23.00 RF REVISION m KEY NOTES: 6 06.27.00 ZONING REVISION _ O1 UNISTRUT 3/8 DIA P1008 SPRING-LOADED NUT (TYP PER HANGER) _J N 3/8"0x6" LAG BOLT " , ,�� 2 UNISTRUT P1000x18 LONG - ATTACH TO WALL WITH ANCHORS AS a„ 0� CO( AUXILIARY STRINGER TUBE O REQUIRED FOR WALL CONDITION �'S'9 OR CABLE RUNWAY 58-155 EXISTING WOOD 3� COAX (SIZE & QUANTITY AS REQUIRED) W/ NON-INSULATING HANGERS 0 SIDING 4'-0" OC MID) K 0H 1/2- CPS COAX W/ NON-INSULATED HANGER ® 48" O.C. (TYPICAL) ;i CAMP ELEC. CONDUIT OR TELEPHONE • -� OEXISTING WALL SURFACE �D AR� COAX SUPPORT �� LADDER WALL CONNECTION WALL MOUNTED ANTENNA DETAIL WALL MOUNTED CABLE SUPPORT W/ SHROUD m All drawings and written material contained 8 NOT USED a 5 6 herein may not be duplicated used or disclosed n'`, without the written consent o the architect. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE. N.T.S. INFORMATION.,:,. WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 n°k fir .i p ROOF—TOP ANTENNAS �c EQUIPMENT ROOM r ARCHITECTURAL D ET . . r 9 NOT USED 10 NOT USED 11 NOT USED 12 NOT USED A - 7 SCALE N T S SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. ��. DWG. NAME A7.dwg DATE: 5/' �x HVAC GENERAL NOTES F AIR HANDLER UNIT SCHEDULE LEGEND --� SYMBOL ABB. DESCRIPTION SYMBOL ABB. DESCRIPTION y SYM MFR & MODEL # AREA COOLING SUPPLY FLA FUSE MCA V PH HZ WT REMARKS ® SAD SUPPLY NR DUCT PD PRESSURE DIFFERENTIAL SWITCH HP ESP 1. THE HVAC CONTRACTOR SHALL PERFORM THE WORK IN ACCORDANCE WITH SERVICED CAPACITY CFM ® .12 f� RAD RETURN NR DUCT s S SWITCH THE BEST ASHRAE AND INDUSTRIAL STANDARDS. AC TRANE SEE PLAN 60,000 BTU 3/4 .55 2000 5.4 15A 15A 208 1 60 120 PROVIDE DISCONNECT 0 GSA OUTSIDE NR - RL - RL REFRIGERANT LIQUID AT&T 2. ALL HVAC WORK SHALL COMPLY WITH ALL APPLICABLE CODES OF THE 1 TWEO63P13FB C!E�11111 EAD EXHAUST NR DUCT - RS - RS REFRIGERANT SUCTION STATE OF COLORADO, LOCAL BUILDING CODES AND FEDERAL CODES, - e0D BDD BACKDRAFT DAMPER - CD - CD CONDENSATE DRAIN ^v HAVING JURISDICTION OVER THE CONSTRUCTION. 2 TWE063P13F8 SEE PLAN 60,000 BTU 3/4 .55 2000 5.4 15A 15A 206 1 60 120 PROVIDE DISCONNECT 0 L LINED DUCTWORK O.C. O.C. ON CENTER 3. HVAC CONTRACTOR SHALL EXAMINE THE PROJECT SITE AND DISCUSS ® CD CEILING DIFFUSER EXIST. EXISTING AT&T Wireless Services GENERAL REQUIREMENTS OF BUILDING AND WORK PERFORMANCE WITH * LOW VOLTAGE SMOKE DETECTOR TO SHUT DOWN UNIT UPON DETECTION & SEND SIGNAL TO EXTERNAL ALARM PANEL FOR AC-1 & AC-2. ® RAR RETURN NR REGISTER a POC POINT OF CONNECTION SUITE C-1 OWNERS REPRESENTATIVE. CONTRACTOR SHALL COORDINATE HIS WORK IN EAR EXHAUST AIR REGISTER Th. THROAT 1001 16TH. STREET WITH THE WORK OF OTHERS ON THE PROJECT. CONTRACTOR SHALL a[-C SWR SIDEWALL SUPPLY REGISTER I.D. INSIDE DIMENSION DENVER, COLORADO 80265-0003 CONFIRM EXISTING CONDITIONS AND PROVIDE ALL LABOR AND O VTR VENT THRU ROOF 0 D OUTSIDE DIMENSION MATERIALS TO MAKE A WORKABLE AND USABLE SYSTEM. CONDENSING UNIT FC FLEXIBLE CONNECTION W WITH 4. HVAC CONTRACTOR IS TO REPORT TO OWNERS REPRESENTATIVE ANY AFD AUTOMATIC FIRE DAMPER S M SHEET METAL OBSERVATIONS OR CONDITIONS WHICH ARE DISCOVERED IN THE }---f. MVD MANUAL VOLUME DAMPER 5 S STAINLESS STEEL ■ BUILDING WHICH WOULD PREVENT THE FULLEST USE OF THE HVAC SYM MFR & MODEL # V PH HZ COMP. FAN MFS SEER WT REMARKS SYSTEM. 101 QBD QUADRANT BALANCING DAMPER GC GENERAL CONTRACTOR ° CU TRANE MODEL DL DOOR LOUVER S-- --s, EXIST. TO REMAIN 5. HVAC CONTRACTOR SHALL ARRANGE AND PAY FOR ALL FEES, PERMITS, 208 1 60 30.7A 1.4A 60A 12 328 LOW AMBIANT KIT AND DISCONNECT - UC UNDERCUT DOOR 3/4' Sf ff f-/-5 EXIST. TO BE DEMOUSHED AND INSPECTIONS CONCERNING HIS WORK. 1 TTP 060D100A r STAT THERMOSTAT ® COMBINATION SMOKE FIRE DAMPER n s CU TRANE MODEL 6. HVAC CONTRACTOR SHALL FIELD VERIFY ALL ELECTRICAL POWER TTP 060D100A 208 1 60 30.7A 1.4A 60A 12 328 LOW AMBIANT KIT AND DISCONNECT H H. STAT HUMIDISTAT 9 SMOKE DETECTOR CHARACTERISTICS PRIOR TO ORDERING ANY MECHANICAL EQUIPMENT. er BT BY-PASS TIMER 7. ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY THE HVAC * LOW VOLTAGE SMOKE DETECTOR TO SHUT DOWN UNIT UPON DETECTION & SEND SIGNAL TO FIRE ALARM PANEL FOR AC-1 & AC-2. TS TEMPERATURE SENSOR CONTRACTOR. 8. THE ROOM THERMOSTATS SHALL BE CAPABLE OF BEING SET FROM 557 TO 857. 9. A DURABLE MAINTENANCE LABEL MUST BE AFFIXED TO MECHANICAL EXHAUST FAN SCHEDULE F. EQUIPMENT. TWO COPIES OF A MAINTENANCE MANUAL FOR THE # Y EQUIPMENT ITEMS SHALL BE PROVIDED TO THE OWNER BY THE AREA WATTS MAX. CONTRACTOR. 5YM MFR & MODEL # SERVICED CFM ESP /BHP V PH WT FAN RPM SONES REMARKS y 10. CONDENSATE DRAINS FROM AIR HANDLER COIL TO BE DWV COPPER EF COOK SEE PLAN 347 5" 351 115 1 35 1075 3.8 W/ BDD AND DISCONNECT. TUBING. GRAVITY DRAINS AND PRESSURIZED DRAINS SHALL BE 1 GEMINI-GC-640 . PROVIDE WITH TOTAL ENCLOSED DRIVE MOTOR. INDIRECT. DRAINS SHALL BE SUPPLIED AND INSTALLED BY THE HVAC CONTRACTOR. 11. THE SUCTION AND LIQUID LINES SHALL BE TYPE "L" HARD DRAWN COPPER TUBING, INSULATED WITH MINIMUM OF 1/2" ARMAFLEX OF EQUAL. SOFT COPPER TUBING MAY BE USED IF NECESSARY TO INSTALL LINES AROUND OBSTRUCTIONS. AVOID SHARP BENDS AS TUBING KDC PINCH CAUSING A RESTRICTION. USE LONG RADIUS ELBOWS WHENEVER OFSSUCTIONITRISERS. BRAZE RADIUS ALL BCU OWS FOR THE TRAP AT THE TO CU JOINTS WITH SILF05-50M GRILLE AND DIFFUSER SCHEDULE Architects - Engineers, PC 12250 EQUIVALENT BRAZING MATERIAL. DO NOT USE SOFT SOLDER. SUCTION BIRDSCREEN East lad Avenue, Suite 302 Auror a, Color ad LINES TO BE SUPPORTED A MINIMUM OF EVERY 8'. LIQUID LINES A WALL EXHAUST FAN- MODEL AM10R Aurora, 80014-1253 MINIMUM OF EVERY 6 . SYM MFR & MODEL # SIZE CFM MATERIAL BORDER TYPE FINISH NECK REMARKS REFER TO SCHEDULE a 303.750.6999 FAX 303.750.0236 Email: kdcdenver@kdcarchitects com 12. INSTALL EQUIPMENT AND RUN PIPES AND DUCTS PARALLEL WITH OR AT SG TITUS 272RS 16"X16" 20D0 STEEL 1 26 WHITE Website: www.kdcarchitects.com RIGHT ANGLES TO THE WALLS OF THE BUILDING UNLESS SHOWN # # PROVIDE AND INSTALL FRAMING OTHERWISE ON THE DRAWINGS. PARALLELED RUNS SHALL BE STRAIGHT 1 FOR ROUGH OPENING. AND TRUE WITH OFFSETS UNIFORM AND SYMMETRICAL. RG TITUS #271RL 20"X14" 2000 STEEL 1 #26 WHITE 13. CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER CONSTRUCTION AT&T WIRELESS SERVICES TIME AS NOT TO DISTRACT FROM NORMAL WORKING CONDITIONS. EG ITUS #355ZR-4D 14x14 375 STEEL 1 #26 WHITE 8" 14. CONTRACTOR SHALL VERIFY PIPE SIZE WITH MANUFACTURER'S REP FOR 1 PROJECT , ■ OVERALL PIPING RUN •• 204033 003 DRAWN GRAVITY BACKDRAFT DAMPER �l DP i r �I POWER EXHAUSTER MKS 12 x 14 DUCT �I NO ISSUE CONTROL. SECUENCE� GASKET 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING SECURE & CAULK 3 05.31.00 ZONING REVISION 1. THE AIR CONDITIONING UNITS SHALL DUTY CYCLE. AIR HANDLER ------ ENTIRE PERIMETER 4 0619.00 ZONING REVISION 5 06.23.00 RF REVISION 2. THE AIR CONDITIONING UNIT FAN WHICH IS LEAD SHALL RUN CONTINUOUSLY. I NJ 6 06.27.00 ZONING REVISION 3. UPON A CALL FOR COOLING, THE LEAD AIR CONDITIONING UNIT SHALL PROVIDE /DAMPER D-1 MOTORIZED ISO �a COOLING. IF THE SPACE TEMPERATURE RISES 3'F ABOVE SET POINT, THE AIR TEC SCREWS (3 PER SIDE) EG N.C. SPRING OPEN 18x18 SHEET METAL CONDITIONING UNIT WHICH IS THE LAG UNIT SHALL PROVIDE COOLING. WHEN 1 ON HYDROGEN DETECTION THE ORIGINAL SET POINT IS REACHED, THE LAG AIR CONDITIONER SHALL CEASE SKIRT THRU WALL ` . OPERATION. ' O RETURN PLENUM 4. THE COOLING SET POINT FOR THE AIR CONDITIONING EQUIPMENT IS 727, , H 'C�.• ADJUSTABLE. CONCRETE FLOOR EXISTING EXTERIOR WALL .� Ua �;{ 5. UPON HYDROGEN DETECTION AC-1, AC-2, CU-1, AND CU-2 SHALL SHUT DOWN � •' OPERATIONS. EF-1 SHALL START AND MAD-1 SHALL OPEN. U130�00 1/2- DIA. ANCHORS, 4 REQUIRED. 816ivAtO•_� 2 WALL MOUNTED EXHAUST FAN 1 SECTION AA M-1 NOT TO SCALE '. m All drawings a d written mat rial cpntained herein may no� be duplicate used or disclosed M-1 NOT TO SCALE without the written consent of the architect. INFORMATION ; I. . THERMOSTAT SUBBASE UPPLY 1�.5„ I WEST VAIL 5 DISCHARGE PLENUM FABRICATE Y2 1'-8 W1 W2 RC RH Y1 1 'S� AT �R[J 1'\ qT SUPP ,T FROM 18 GA. SHEET METAL 1 -5 RE( 1pry �Y 2077 N. FRONTAGE RD. (FINISH TO MATCH A.H.) �9M PT qT R� � �R VAIL, COLORADO 81657 N R Y BR W BK ,:LANG RH Y1 Y2 W1 W2 RC 1" ROLL(4)FSID SE 1/8" O.D. FLARE POP RIVET a SG ° MARVAIR CONTROLLER #LL357 SCREW PLENUM TO FLANGE ON A.H. 7�-5" MAX' °I I 45' GUSSET ° 18 GA SHEET METAL (8 PLACES) - - - - _ C- - - - - � r - - - 18 GA. - - -I R JOINT ROOF-TOP ANTENNAS & 2 1/2"x2 1/2"x6 LONG C W � Y I W Y I ' Q Q I EQUIPMENT ROOM ANGLE 14 GA.. ANCHOR TO WALL WITH � I � 4 3/8" WOOD SCREWS IN WOOD BLOCKING, - _ I r - I ATTACH TO A.H. WITH 2 - #12 TECS. (EACH SIDE) SHIIEETJITLE RG 1,_ _ I I I I I I RETURN PLENUM FABRICATE �C W �Y �G R Et �W TOP TAB ` FROM 18 GA. SHEET METAL MECH DETAILS, NOTES i A/C #1 A/C #2 (FINISH TO MATCH A.H.) SINGLE 45' � DOUBLE 45' JOINT CUT END 90' TAB f �_ AND SCHEDULES 1'-11 1/2"1 1'_g^ M-I FACTORY WIRING 90' 90' 9D' 90, ° -g0 TAB - - - - FIELD WIRING BY MECH. CONTR. END SECTION * VERIFY DIMENSION AS REQUIRED TO MATCH UNLESS OTHERWISED NOTED. • AR SMS SHEET NUMBER 45 1 8 RIVET OR 5 5T f„ AIR HANDLER FURNISHED. 3 DISCHARGE AND RETURN PLENUMS 4 ENVIRONMENTAL CONTROL PANEL SCHEMATIC (ECP) 5 PLENUM DETAILw= r M-1 NOT TO SCALE NOT TO SCALE M-1 NOT TO SCALE M -1 * VERIFY DIMENSION AS REQUIRED TO MATCH AIR HANDLER FURNISHED. DWG. NAME:M 1.DWG DATE: 5/19/00 2:40 PM a. 12 15 AT&TGROUND MOUNTED GROUND MOUNTED 1 CONDENSER CU-2 CONDENSER CU-1 1 9. AT&T Wireless Services 8 SUITE C-1 1001 16TH. STREET WALL PENETRATION DENVER, COLORADO 80265-0003 4 13 LOIN AMBIENT RETROFIT SHALL BE BUT NOT LIMITED TO � 19 20 EF-1 TXV• TAYTXVAOH5C (5-6 TON ONLY) SOLENOID VALVE: VERIFY WITH TRANE 101 _ n CONTROLER: BAYLOAM102A (XE 1200 (TTP) 10 ONLY) MAD-1 CONTROLER: BD.CONTROLER: SAYLOBOX01A (TTP060100A ONLY) --"— CONDENSER MOTOR: BAYMOTR3068 (TfP06OC100A ONLY) I 24V AC-1 TRAY E ��. 10 9 LISTED ABOVE ARE GENERAL PERAMITERS TO RETROFIT SPLIT SYSTEMS TO OPERATE TO MIN —20'F. CONTRACTOR 15 RESPONSIBLE TO VERIFY INFORMATION ABOVE AND CONTACT A TRANE MANUFACTURING REP TO OBTAIN CORRECT EQUIPMENT TO PROVIDE ABOVE PERFORANCE. CONTRACTOR SHALL PROVIDE LOW AMBIENT 2 7 I 24V C 21 LAF-1 EQUIPMENT AND LABOR IN CONSTRUCTION BID. I BAIT. 14 I I � PANEL 11 H 1 200A HVAC KEY NOTES I I LAF-0 I ® SUITE A AT&T EQUIPMENT K C OPAD MOUNTED CONDENSERS. INSTALL ON GRADE AS PER MANUFACTURER'S INSTRUCTIONS. TESL ROOM Architects — Engineers, P.0 REFER TO ARCH. DTLS OF A6 FOR ADDITIONAL INFORMATION AND LOCATIONS. I SW ( RCF-0 I 12250 East Iliff Avenue, Suite 302 OINSTALL AIR HANDLING UNITS PER MANUFACTURER'S INSTRUCTIONS AND PER DETAILS INDICATED Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 ON M1 DRAWINGS. I GP5 I Email: kdcdenver®kdcarchitects com OAT&T RADIO EQUIPMENT PROVIDED & INSTALLED BY OTHERS. DISCON'T 2424 SUITE B www.kdcarchitects.com SWITCH O REFRIGERANT LINES UP AND THROUGH EXISTING WALL. TYPICAL FOR 2 CIRCUITS, 4 PIPES. I I I I AT&T WIRELESS SERVICES s O5 ENVIRONMENTAL CONTROL PANEL: PROVIDE AND INSTALL ALL WIRING FROM MARVAIR RCF-1 F' CONTROLLER. SEE SCHEMATIC ON M-1 FOR CONTROL WIRING. MOUNT 66 . .A.F.F. I GP5 I • 2424 OHIGH AND LOW TEMPERATURE ALARM THERMOSTATS: PROVIDE AND INSTALL TWO (2) HONEYWELL FUTURE 204033 OD3 FARM–O–STATS T631A1006. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND SIGNAL WIRING DRAWN TO EXTERNAL ALARM PANEL. MOUNT AT 66" A.F.F.. I 3 FUTURE RCF-2 SMT 7O REFERENCE DETAIL 3/M-1. I EQUIPMENT L t� j CHECKIEIDBY O REFERENCE DETAIL 2/M-1 FOR NEW EXHAUST FAN EF-1. MKS ISSUE O9 NEW 14x12 EXHAUST DUCT REFERENCE 2 M-1. I i _NO , • + / I FUTURE AIF _ 1 03.03.00 CLIENT REVIEW/ZONING I I �� 10 TRANSITION FROM FAN COLLAR TO LISTED EXHAUST DUCT SIZE. EQUIPMENT 2 2 04.21.00 ZONING I FUTURE ,�z 3 05.31.00 ZONING REVISION 6 11 CEILING MOUNTED HYDERGEN SENSOR, RE ELECTRICAL DWG. FOR WIRING AND OPERATION. I T I 4 0619.00 ZONING REVISION CABLE TRAY 5 06.23.00 RF REVISION A/C 6 06.27.00 ZONING REVISION <a> NEW LIQUID AND SUCTION LINE. CONTRACTOR SHALL SIZE PER MANUFACTURE INSTRUCTIONS. 5 PANEL SUPPORT PIPING PER STATE AND LOCAL CODE. T I I 1 AF :#, <a> FIRE SEAL ALL PIPING WALL PENETRATION TYPICAL. - 6 8G I j 08 / RELAY FUTURE L� •..ee.e r 14 CONDENSATE DRAIN, RUN TIGHT TO STRUCTURE, TERMINATE AT CLOSEST INDIRECT OB.• �� 9 DRAIN. PROVIDE CONDENSATE PUMP EACH UNIT. 1- 7 15253 <S> CONTRACTOR SHALL VERIFY LIQUID AND SUCTION PIPING RUN, PROVIDE AND INSTALL I 3 CDPD { �� lfl�3o\0�•;��, SUPPORTS PER STATE AND LOCAL CODES. I EXT. ALARM GROW I ` ° 16 CONTRACTOR SHALL VERIFY PIPING ROOF PENETRATION, TYPICAL OF 4 LINES. PANEL s�ONA\- 17 NOT USED m�II drawings aq be dup icate ud writtenl, ed or disclosed material s contained 18 NEW 14x14 MAKE–UP AIR DAMPER AND THRU WALL DUCT. TERMINATE BELLOW CEILING. MAD-2 PCs 3 erein may no PRI without the written consent of the architect. - SHALL SPRING OPEN ON START OF EF-1 AND POWER CLOSE. � I I l- 19 MAD-1 AND MAD-2 FIRE DAMPER NORMALLY CLOSED, ON START OF EF-1 DAMPER SHALL SPRING INFORMATION, OPEN TO PROVIDE MAKEUP AIR. 2 7 20 FIRE DAMPER IS RUSKIN FD60, 1-1/2 HOUR RATED, WITH ROUND DUCT TRANSITION AND .�" 120V BLADE OPERATOR AIR STREAM LOCATION. DAMPER NORMALLY CLOSED, UPON EF-1 — — — _ WEST VAI L START DAMPER SHALL SPRING OPEN. MAD-1 AND MAD-2 8 21 CONTRACTOR SHALL RELOCATE EXISTING EXHAUST FAN AND DUCT WORK TO REVISED REST ROOM. I `s 2077 N. FRONTAGE RD. CONTRACTOR SHALL VERIFY RELOCATION AND MATERIAL REQUIRED. FAN SHALL BE SWITCH OPERATED. 14 VAIL, COLORADO 81657 18 MAD- DESIGNZ , NOTE � #f CONTRACTOR TO REVIEW AT&T SPECIFICATIONS I PRIOR TO BID. I ROOF-TOP ANTENNAS & T.O.S. & ka EQUIPMENT ROOM TRANE REPRESENTATIVE ALARMS e SHEET sTITLE' a, JOE BUSHARD 303-228-2831 i 303-228-2828 FAX 445 BRYANT STREET #5 DENVER, COLORADO 80204 MECHANICAL P LAN CONSTRUCTION EQUIP. PLA SCALE: 1/2" = 1'-0" SHEET' f .■ ■ 0 2' 4' 6' i SCALE FEET M 2 i DWG. NAME: M 2.DWG DATE: 5/19/00 2:40 PM i i ELECTRICAL SPECIFICATION GENERAL NOTES NOTE: POWER AND TELCO TO BE j y 1. ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGES AND HORSE- COORDINATED WITH OWNER, 1 . THE ELECTRICAL INSTALLATION WORK SHALL COMPLY WITH ALL POWER RATINGS OF ALL MECHANICAL EQUIPMENT. AT&T PROJECT MANAGER AND LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES 2. PRIOR TO INSTALLING ANY ELECTRICAL WORK, THE ELECTRICAL UTILITY COMPANIES AT&T APPLICABLE TO ELECTRICAL WORK. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND REQUIREMENTS 2. ELECTRICAL CONTRACTOR SHALL VISIT JOBSITE AND VERIFY ON THE JOB AND BY REFERENCE TO ARCHITECTURE, MECHANICAL EXISTING CONDITIONS BEFORE BIDDING AND SHALL INCLUDE AND EQUIPMENT SUPPLIERS DRAWINGS. SHOULD THERE BE ANY AT&T Wireless Services IN HIS BID THE NECESSARY COSTS TO CONSTRUCT THIS PROJECT QUESTION OR PROBLEM CONCERNING THE NECESSARY PROVISIONS ; SUITE C-1 1001 16TH. STREET IN ACCORDANCE WITH INTENT OF THE ELECTRICAL DRAWINGS, TO BE MADE, PROPER DIRECTIONS SHALL BE OBTAINED BEFORE DENVER, COLORADO 80265-0003 SPECIFICATIONS, AND ALL APPLICABLE CODES. PROCEEDING WITH ANY WORK. 3. ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED UNDER 3. OUTLET AND JUNCTION BOXES SHALL BE SIZED PER CODE FOR THE f THIS CONTRACT SHALL BE NEW, FREE FROM DEFECTS, AND SHALL ■�� �� ■ BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL QUANTITY OF WIRES THEY CONTAIN. SEE ARTICLE 370-6 OF N.E.C. ACCEPTANCE BY OWNER OR HIS REPRESENTATIVE. SHOULD ANY PROVIDE ADDITIONAL BOXES AND EXTENSION RINGS AS REQUIRED. TROUBLE DEVELOP DURING THIS PERIOD DUE TO FAULTY WORK- MANSHIP, MATERIAL OR EQUIPMENT, THE CONTRACTOR SHALL FURNISH ALL NECESSARY MATERIAL AND LABOR TO CORRECT THE ! TROUBLE WITHOUT COST TO THE OWNER. T TELEPHONE SERVICE r 4. ALL WORK TO BE EXECUTED IN WORKMANLIKE MANNER AND SHALL E ELECTRICAL SERVICE PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. 1W CONDUIT RUN EXPOSED 5. ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE LISTED (hash marks indicate no. of wires, less gnd.) BY UNDERWRITER'S LABORATORIES. - — — — — - CONDUIT RUN CONCEALED 6. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL GROUNDING CONDUCTOR CUTTING AND PATCHING RELATED TO ELECTRICAL WORK, UNLESS ____________ NOTED OTHERWISE AND COORDINATED WITH THE GENERAL O 5/8" DIA. X 8'-0" L, COPPER-CLAD ' CONTRACTOR. STEEL GROUND ROD. 7. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK WITH GROUNDING CONNECTION -� MECHANICAL AND ARCHITECTURAL PLANS. THE REQUIREMENTS OF KDC ALL EQUIPMENT ACTUALLY BEING INSTALLED SHALL BE VERIFIED TRANSFER SWITCH I i Architects - Engineers, P.C. PRIOR TO INSTALLING THE ELECTRICAL WORK. I- J -� 12250 East Iliff Avenue, Suite 302 8. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER TYPE "THHN" DISCONNECT SWITCH m EXISITNG PROPERTY LINE Aurora, Colorado 80014-1253 #12, & #10 SOLID, #8 AND LARGER STRANDED. — — — — — — — — — Email: kdcdenver®kdcarcchit ctts..com 9. ON COMPLETION OF THE WORK, THE INSTALLATION SHALL BE FREE 0— CIRCUIT BREAKER m f Website: www.kdcarchitects.com FROM GROUNDS AND SHORT CIRCUITS. i 10. ELECTRICAL CONTRACTOR SHALL FURNISH AS-BUILT DRAWINGS TO O ELECTRIC MOTOR THE ARCHITECT ON COMPLETION OF THE JOB. mr- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ( AT&T WIRELESS SERVICES ® ELECTROMAGNETIC RELAY OR MOTOR STARTER I I 4 ' ' e 11 . ELECTRICAL WORK SHALL INCLUDE ALL LABOR, MATERIALS AND 1 I , EQUIPMENT REQUIRED, INCLUDING BUT NOT LIMITED TO COMPLETE I UTILITY EASEMENT ' 204033.003 mi i ELECTRICAL SYSTEMS POWER AND LIGHTING, TELEPHONE CONDUIT . ELECTRICAL METER I � ' SYSTEM, SIGNAL SYSTEMS, PANELBOARDS (S), CONTROL WIRING, SMT GROUNDING, CONDUIT ONLY SYSTEMS, ETC., AS INDICATED ON ® GENERATOR RECEPTACLE m MECHANICAL & ELECTRICAL DRAWINGS AND/OR REQUIRED BY I ;CHECKED • GOVERNING CODES. J-- GROUND ! MKS _ � 10' ELECTRICAL EASEMENT 12, RACEWAYS SHALL BE: m RIGID STEEL CONDUIT: ZINC-COATED OR SHERARDIZED HEAVY WALL O ELECTRICAL FEEDER IDENTIFICATION EXISTING U.G. I i 1 03.03.00 CLIENT REVIEW/ZONING AS MANUFACTURED BY REPUBLIC,TRIANGLE OR EQUAL. \ TELCO RUN —� 10' ELECTRICAL EASEMENT I 2 04.21.00 ZONING CI ELECTRICAL PANEL RIGID POLYVINYL CHLORIDE CONDUIT (PVC): HEAVY WALLS SCHEDULE 3 05.31.00 ZONING REVISION PROPOSED 40 AS MANUFACTURED BY CARLON ELECTRICAL, VISQEEN OR EQUAL. DUPLEX RECEPTACLE 20A, 120V I PROPOSED MOBILE CONDENSOR 4 06.1900 ZONING REVISION GENERATOR RECEPTACLE 5 06.23.00 RF REVISION ELECTRICAL METALLIC TUBING (EMT): ZINC-COATED THIN WALL AS QUAD RECEPTACLE 20A, 120V I UNITS 6 06.27.00 ZONING REVISION MANUFACTURED BY TRIANGLE, REPUBLIC OR EQUAL. 13. FUSE TYPE SHALL BE BUSSMANN FRN-S TYPE FUSES S SWITCH 2OA-1 P AF �M ELECTRICAL MOTOR TV RISE O REG�` 14. PROVIDE ENGRAVED PLASTIC LABELS TO IDENTIFY ALL PANELBOARDS, I TIE WALL XFMRS., DISTRIBUTION PANELS.,DISCONNECT SWITCHES., TRANSFER oQ: SWITCHES. LABELES SHALL READ IN THIS FASHION "A" 208Y/120V O MOTORIZED DAMPER 24� 3W, 200A, CKT.BKR OR FUSES TYPE AND SIZES EXISTING PAD MOUNTED I I II ��� 15253 �e TRANSFORMER 300 KVA TRANS— PROPOSED " r 2 X 4 FLORESCENT RECESSED LIGHTING FIXTURE FORMER I , (,\3olaa U �' 15. E.C. SHALL VERIFY AND TEST GROUND TO SOURCE TO A MAXIMUM 30, SEC.: 208/120V ELEC. RUN k" OF 5 OHMS. IF THE GROUND TEST DID NOT ACHIEVE THE 5 OHMS Q KEYLESS 24 V DC SURFACE MOUNT FIXTURE m I PROPOSED I I 4zweoNAL�' OR LESS. E.C. SHALL NEGOTIATE WITH OWNER TO PROVIDE I — C T CAB O 5�D SMOKE DETECTOR EXISTING U.G. ADDITIONAL GROUNDING AS REQUIRED. —I F ELECTRICAL RUN m F PROPOSED ❑ HYDROGEN \ UTILITY CO. I I ®AII drawings and written material contained 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUESTING •' METER I herein may not be duplicated used disclosed APPLICATION OF SERVICE ON BEHALF OF AT&T WIRELESS. - M ELECTRICAL MOTOR � I F I without the written consent 61 the arcc hitect. O p MOTORIZED DAMPER w Z SUITE A J I m AT&T Of SUITE A EQUIPMENT I II WEST VAI L ABBREVIATIONS a ROOM I i � ' m F.B.O. = FURNISHED AND INSTALLED BY OTHER TRADES OR z 2077 N. FRONTAGE RD. CL I Y CONTRACTOR NOTES OWNER, CONNECTIONS BY ELECTRICAL CONTRACTOR N I + DUMPSI ER PROPELCO I VAIL, COLORADO 81657 FURNISHED BY OTHER TRADES OR OWNER - f — RUN — — — — — F.8.0.E. � w � INSTALLATION AND CONNECTION BY ELECTRICAL CONTRACTOR. I II F.B.M. = FURNISHED BY MECHANICAL. f m I — 1 . BEFORE SUBMITTING BID, VERIFY EXISTING SITE CONDITIONS, C.O. = CONDUIT ONLY — — — — — — — — EMT. = ELECTRICAL METALLIC TUBING (THIN WALL) ° ELECTRICAL SERVICE REQUIREMENTS AND THE EXACT SERVING PVC. = SCHEDULE 40 PVC CONDUIT. — T T T T T UTILITY POINTS OF CONNECTION. RGSC. = RIGID GALVANIZED STEEL CONDUIT �' I -- PROPOSED TELCO 2. THE ELECTRICAL CONTRACTOR (E.C.) SHALL FURNISH AND PAY N.L. = NIGHT LIGHT. �' I BOARD MTD. = MOUNTED. I i I ROOF—TOP ANTENNAS & FOR ALL PERMITS AND RELATED FEES. W.P. = WEATHERPROOF. EXISTING U.G. I I EXISTING TELCO I EQUIPMENT ROOM 3. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL ELECTRICAL U.O.N. = UNLESS OTHERWISE NOTED. TELCO RUN -, I BOARD A` MATERIALS, EQUIPMENT AND WORK, SHOWN ON THESE PLANS G. OR GRID. = GROUND.N. OR NEUT. = NEUTRAL. I i ARE NEW TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL SN = SOLID NEUTRAL. C SHEET TITLE ONTRACTOR. A. OR AMP. = AMPERE. + -' 4. E. C. SHALL FURNISH AND INSTALL ALL SWITCHES, CONDUIT, KW. = KILOWATTS. ' WIRES, BOXES, LIGHT FIXTURES (INCLUDING LAMPS), SERVICE W. = WATTS. ELECTRICAL SPEC. , DEVICES, RECEPTACLES, SWITCHBOARDS AND PANELBOARDS, ETC. L.V. = LOW VOLTAGE. NOTES, SYMBOL LIST REQUIRED FOR A COMPLETE AND OPERATING ELECTRICAL SYSTEM. 0 = PHASE. C.L. = CURRENT LIMITING. ( NOTES, SYMBOL LIST, 5. E. C. SHALL BE RESPONSIBLE FOR CONFORMANCE WITH THE D.E. = DUAL ELEMENT. NATIONAL ELECTRICAL CODE, STATE OF COLORADO ELECTRICAL AFG = ABOVE FINISHED GRADE ABBREVIATIONS AND BFG = BELOW FINISHED GRADE ELECTRICAL SITE PLAN - FIRST FLOOR SAFETY ORDERS, ALL LOCAL CODES AND ORDINANCES AND ALL AFF = ABOVE FINISHED FLOOR OTHER ADMINISTRATIVE AUTHORITIES HAVING JURISDICTION OVER XFMR = TRANSFORMER. 1 SCALE: 1/4" = V-0" i ■ THIS WORK. C.B. = CIRCUIT BREAKER. i CKT. = CIRCUIT. 6. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL/LOCATION SW. = SWITCH. INFORMATION RELATING TO THE ELECTRICAL DRAWINGS. TRANSF. SW = TRANSFER SWITCH ' F.A. = FIRE ALARM. RECPT. = RECEPTACLE. M.C. = MECHANICAL CONTRACTOR. E.C. = ELECTRICAL CONTRACTOR. G.C. = GENERAL CONTRACTOR. DWG. NAME E1.dw DATE: 5/19/00 2:40 PM f G, AT&T �t AT&T Wireless Services a SUITE C-1 1001 16TH. STREET DENVER, COLORADO 80265-0003 DEMOLITION PLAN KEYED NOTES I. O DISCONNECT AND REMOVE EXISTING BASEBOARD HEATERS AND ASSOCIATED WIRING. O DISCONNECT AND REMOVE EXISTING SURFACE MOUNTED { LIGHTING FIXTURES AND ASSOCIATED WIRING. CIRCUIT BREAKER 0 DISCONNECT AND REMOVE EXISTING WALL MOUNTED I TELEPHONE RECEPTACLES AND ASSOCIATED WIRING. ELECTRIC HOT WATER ® DISCONNECT AND REMOVE EXISTING TELEPHONE OUTLETS TRANSFORMER AND ASSOCIATED WIRING. } EXHAUST FAN SWITCH W/LIGHT O DISCONNECT AND WIRING. EXISTING LIGHT SWITCHES . 1 2 ® 3 © DISCONNECT AND REMOVE IXISITNG ELECTRIC PANEL AND 1 ASSOCIATED WIRING. INSTALL THIS PANEL IN NEW LOCATION AS INDICATED ON THE DRAWING. ESTABLISH NEW PANEL D FEEDER NTHE SAM PANEL EXISTING) AND INSTALL NEW AV —J 3 I O REMOVE EXISTING WIRING OF EXISTING WATER HEATER TO BE KDC RELOCATED IN RESTROOM. RELOCATE THE WATER HEATER. 4 I 8 I f 3 6 DISCONNECTING MEANS AND CONTOL INSIDE TOILET AREA. Architects — Engineers, P C TRANSFORMER �\O I I ESTABLISH NEW HOME RUN TO THE ELECTRIC PANEL 12250 East Iliff Avenue, Suite 302 3 5 I I © REMOVE EXISTING INCANDESCENT LIGHTING FIXTURES, 303.750 6999 Colorado FAX 303.750.0236 -� 7_ L_ ' I I AND ASSOCIATED WIRING.REMOVE EXISTING EXHAUST FAN, AND "I Email: kdcdenver@kdcarchitects com L ___ — �� I O Website: www.kdcarchitects.com F-� \ � / 5 ASSOCIATED WIRING AND CONTROLS. 3 _j 2 AT&T WIRELESS SERVICES 1 PROJECT NUMBER , 204033 003 GENERAL NOTES 4 f DRAWN rL —— —— —— SMT -- -- -- - --- -- SUITE B 5 1. COORDINATE DEMOLITION PROCESS WITH GENERAL CONTRACTOR 4 AND OWNER. I I 4 §. MKS 2. ELECTRICAL EQUIPMENT TO BE REUSED FOR NEW CONSTRUCTION i DATE �—x x—®x—x—x x x SUITE A 3 AT&T —— , >0 EQUIPMENT SHALL BE CLEANED, INSPECTED AND PROPERLY STORED. x x EQUIPMENT f 1 03.03.00 CLIENT REVIEW/ZONING 2 3. EXISTING ELECTRICAL EQUIPMENT NOT FLAGGED BY KEY NOTES IS 2 04.21.00 ZONING ROOM / TO REMAIN. PORTION OF WIRING TO BE REUSED FOR NEW WIRING �T SHALL REMAIN IN PLACE. 3 05.31.00 ZONING REVISION 5 3 4 06.19.00 ZONING REVISION '® DUMPSTER ®` I I 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION C C II 3 2 I I I �, oQ,POO REG/, H�S IJ W e ` NAk- 1 II 5 3 ®All drawings and written material contained --4rH herein may not be duplicated used or disclosed without the written consent 61 the architect. INFORMATION, I I WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81 657 I ROOF-TOP ANTENNAS & EQUIPMENT ROOM i I I I i DEMOLITION PLAN (:D_KDEEM10L1T10N PLAN E: 2 DWG. NAME: E2.dw DATE: 5/19/00 2:40 PM POWER PLAN KEYED NOTES POWER PLAN KEYED NOTES CONTINUED GROUNDING PLAN KEYED NOTES 1O AT&T EQUIPMENT BY OTHERS 3Q EXISTING ELECTRIC PANEL INSTALLED TO NEW LOCATION, PANEL A SHALL HAVE A 225 AMP BUS, 1 PHASE, 3W, CIRCUITS, MAIN C/BREAKER 20OA-2P, NEMA TYPE 1 ENCLOSURE, SURFACE ESTABLISH NEW HOME RUNS FROM EXISTING BASEBOARD HEATERS TO RELOCATED EXISTING PANELBOARD USING # MOUNTED, SQUARE "D" NQOD OF EQUAL. EXISTING WIRE SIZES. USE EXISTING CIRCUIT BREAKERS. INTERNAL NOLC.�HM N." BENDING RADIUS�ISHALL BE MOUNTED AT 96" A.F.F. USING NYLON CLIPS b OFUTURE ELECTRICAL EQUIPMENT. <8> ESTABLISH NEW HOME RUNS (2#12 & 1#12G.) 1/2" C. FROM RECEPTACLES TO RELOCATED EXISTING PANELBOARD. O SERVICE DISCONNECT SWITCH 40OA-2P, 120/240V O4 SURGE ARRESTOR: JOSLYN #1456-08 (OR APPROVED EQUAL) MOUNTED NEXT TO PANEL "A" O3 USE COMPRESSION CONNECTION TO "HALLO" CONDUCTOR ,' AT&T Wireless Services SUITE C-1 O AIR CONDITIONER UNIT, REFER TO MECHANICAL DRAWINGS FOR SCHEDULE. 1001 16TH. STREET O #6 CU TO METAL DOOR FRAME. DENVER, COLORADO 80265-0003 OCONDENSER UNIT, ROOF-MOUNTED (NOT SHOWN), SEE MECH DRAWINGS. ;A. O5 #6 CU TO AT&T EQUIPMENT (TYPICAL) °. DUPLEX RECEPTACLE ® 12" A.F.F. UNLESS OTHERWISE NOTED. TIP. 5 ( ) 7 #2 CU FROM RADIO EQUIPMENT GROUND BUS TO MASTER GROUND BAR. O EXTERNAL ALARM PANEL: O #6 CU TO CABLE LADDER GROUND WIRE. ALARM PANEL IS PROVIDED & INSTALLED BY LUCENT. CONTRACTOR SHALL PROVIDE 1-1/2" CONDUIT FROM ALARM PANEL TO NEAREST CABLE LADDER. E.C. SHALL RUN ( 2 #22 AWG. -1/2" CONDUIT FROM ALARM PANEL TO EACH OF THE FOLLOWING ITEMS O7 MASTER GROUND BAR. UNLESS OTHERWISE NOTED. 1. SMOKE/HEAT DETECTOR. O (1#1/0 CU THHN) 1/2-C FROM MASTER GROUND BAR TO 40OA-2P SERVICE DISCONNECT ® ■ , 2. SURGE ARRESTOR ALARM CONTACTS. 3. MAGNETIC DOOR ALARM CONTACTS. SWITCH GROUND BAR. y 4. HIGH TEMPERATURE THERMOSTAT. O (1#1/0 CU THHN) 1/2" CONDUIT FROM 40OA-2P SERVICE DISCONNECT SWITCH 5. LOW TEMPERATURE THERMOSTAT. ' 6. RECTIFIER ALARM. TO GROUND ROD OF EXTERIOR GROUND RING. 7. POWER FAILURE RELAYS. 8. DC POWER FAILURE RELAYS. <3> #6 TO WAVE GUIDE ENTRY PLATE LOCATION RE: A-3. OTELEPHONE TERMINAL BACKBOARD: 4'xB'x3/4" FIRE RETARDANT PLYWOOD. SEE CONSTRUC11ON KEY NOTE #5 ON SHT. A-2. <a> HVAC EQUIPMENT TO BE GROUNDED BY FEEDER GROUND WIRE. <S> QUAD RECEPTACLE FOR TELEPHONE TERMINAL MTD. 0 6'-0". A.F.F.O all TWO-PIECE MAGNETIC DOOR ALARM: ADEMCO #39-2, (OR APPROVED EQUAL). RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL. <9> GROUNDING CONDUCTOR Q TO BE CONNECTED TO COLD WATER SERVICE PIPE. SEE NOTE® <g> #6 CU TO EXHAUST FAN EF-1 METAL DUCT. 12 ENVIRONMENTAL ALARMS: HIGH & LOW TEMPERATURE ALARMS MTD. ON WALL RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL. MAW SEE NOTE© <3> GROUND ROD 5/8" DIA. X 8" L COPPER-CLAD STEEL. N=%Aw D C 13 POWER FAILURE RELAYS: INSTALL POWER FAILURE RELAYS IN 6"4"x4" ENCLOSURE. MOUNT ON WALL NEXT TO PANEL "A". Architects - Engineers, PC ROUTE ALARM CONDUCTOR TO EXTERNAL ALARM PANEL. 12250 East Iliff Avenue, Suite 302 <3> ENVIROMENTAL CONTROL PANEL:- RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL AND PROVIDE POWER WIRING AS SHOWN. GROUNDING GENERAL NOTES Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 OGENERATOR RECEPTACLE, COORDINATE WITH PROPERTY MANAGER FOR EXACT LOCATION ON EXTERIOR OF THE BUILDING. Email: kdcdenvergkdcarchitects com REFER TO ONE—LINE DIAGRAM (E-1) FOR WIRING INFORMATION WALL MOUNTED 3'-0" A.F.F. LIGHTING PLAN KEYED NOTES 1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. Website: www.kdcarchitects.com ACTUAL GROUNDING INSTALLATION AND 16 EXHAUST FAN WITH FIRE/SMOKE DAMPER. REFER TO MECHANICAL DRAWING FOR TYPE AND POWER REQUIREMENTS. SEE 1 ALL LIGHTING WIRING SHALL BE COPPER 12 AWG. WITH THHN INSULATION RATE 600V, 90'C. CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC <S> FAN CONTROL DIAGRAM E-4 . O # CONDITIONS. ( ) AT&T WIRELESS SERVICES O UTILITY CO. METER 400A, 1�, 120/240V. O PROVIDE KEYLESS PORCELAN FIXTURE W/ 24V DC LAMP FOR EMERGENCY LIGHTING (TYP. OF 6). 2. ALL GROUNDING CONDUCTORS SHALL BE TINNED COPPER. CONNECT TO 24V DC RECTIFIER CIRCUIT BREAKER AND PROVIDE SWITCH BY DOOR SO THAT UNLESS NOTED OTHERWISE. PROJECT: NUIVI: ■ LIGHTING FIXTURE IS NORMALLY SWITCHED ON BY TECHICAN DURING POWER OUTAGE ONLY. MANUAL TRANSFER SWITCH 2OOA-2P, SN, 120/240V. REFER TO ONE-LINE DIAGRAM ON E-1. 3. GROUND SYSTEM MUST BE TESTED BY CONTRACTOR AND 204033 003 1$ MOUNTING HEIGHT 5'-0" A.F.F. O3 PROVIDE IONIZATION SMOKE/HEAT DETECTOR FIRE-LINE 120V AC, OR EQUAL MOUNT TO STRUCTURE SHALL HAVE A RESISTANCE OF 5 OHMS OR LESS. ABOVE CEILING GRID. ROUTE ALARM CONTRACTS TO ALARM PANEL ROUTE AUXILARY CONTACTS TO SUBMIT AN INDEPENDENT TESTING REPORT. f. � ■ ` 19 C.T. CABINET 400A, 120/24OV. A.C. UNITS FOR UNIT SHUT DOWN. 4. NOTIFY ARCHITECT/ENGINEER IF THERE IS ANY SMT DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE D 20 400AMP-2P, 120/240V FUSED SERVICE DISCONNECT SWITCH MOUNTED ON WALL. O4 NEW SURFACED MOUNTED INCANDESCENT LIGHT. TO COLD WATER CONTINUITY TO GROUND. MKS OINSTALL NEW FEEDERS (2#6 & 1#8G) 3/4"CONDUIT FOR CONDENSING UNITS. REFER TO PANEL "A" SCHEDULE E-1 O 2'x4' RECESSED FLUORESCENT STA11C TROFFER, 120VAC, WITH 2 LAMPS ra`. • • , FOR CIRCUIT NUMBERS AND C/BREAKER SIZE. (LITHONIA CAT. # 2SPG-232-120 OR EQUAL). 22 INSTALL NEW FEEDERS (2#12 & 1# 12G) 1/2" CONDUIT FOR AC UNITS. REFER TO PANEL "A" SCHEDULE O EXISTING PANELBOARD 100A, 30, 4W IN NEW LOCATION I 1 03.03.00 CLIENT REVIEW/ZONING CIRCUIT NUMBERS AND C/BREAKERS SIZE. b° 2 04,21.00 ZONING ONEW EXHAUST FAN. ' 3 05.31.00 ZONING REVISION 23 INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR CONVENIENCE RECEPTACLES. REFER TO PANEL "A" SCHEDULE. 4 0619.00 ZONING REVISION E-1 FOR CIRCUIT NIMBERS AND C/ BREAKER SIZE. O EXISTING LIGHTING FIXTURES INSTALLED IN NEW LOCATION. 5 06.23.00 RF REVISION :� 6 06.27.00 ZONING REVISION INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR EXHAUST FAN, REFER TO THE EXHAUST O EXISTING LIGHTING FIXTURES TO REMAIN IN THE SAME LOCATION.24 FAN CONTROL DIAGRAM ON PAGE E-4. <3> NEW LIGHTING SWITCH 20A-1P. } <8> INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR HYDROGEN DETECTOR. 11 ESTABLISH NEW WIRING AND HOME RUN TO EXISTING RELOCATED PANELBOARD. .` a 26 INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR QUAD RECEPTACLE. REG/ ° r P , 27 EXISTING TELCO DEMARC CABINET. 14 O a { 2$ NEW TELCO CABINET BY OTHERS. MP.) e O INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR SMOKE DETECTOR. °AIL — —— EF-1 ®All drawings and written material contained A-6 8 11 I 1 1 herein may not be duplicated used or disclosed ° 60A-2P, 240V 21 � I without the written consent o the architect. A-27 6 I 10 t? *:::R--�E A-5,7 21 60A-2P, ❑ 13 240V v ■A-1,3 22 6 CU-2 GEN CU-1 6 27 16 EF-1 11 TO EXIST.CPT 28 PANELBD. A 12 1 11 I YF W EST VAI L I 6 (all 2077 N. FRONTAGE RD. A-13 Nm M VAIL COLORADO 81657 31 5 22 I A-26 N 9 4 . TO 24 V DC • 'Ilk 24 RECTIFIER _--� 8 C.T. 4 2 `�` H 19 CAB Q A-28 2 32 G 18 8 25 d 1 � 9 (TYP. of 3) 20 aN� 15 I .� METER & 3 ROOF—TOP ANTENNAS 8e SERVICE A-31 ENTER A-25 I EQUIPMENT ROOM 31 12 Ex N 14 9 8 3 13 —21 a (TYP. of 3) I 5 (TYP.) SHEET TITLE 8 � 0 1 5 I o '09 (TYP.) 11 POWER, LIGHTING, AND ��T—A-22 A-2,4� cl, I GROUNDING PARTIAL a i I ' PLANS AND NOTES 9 (IYP, of 3) 2 1 a 23 (TYP.) 31 A-24 26 DL (TYP. OF 5) — —— ——J 32 11 T.O.S. 7 ALARM 10 1 3 POWER PLAN LIGHTING PLAN GROUNDING PLAN 1 SCALE: 3/16" = 1'-0" 2 SCALE: 3/16" = 1'-0" SCALE: 3/16" = 1'-0" „I DWG. NAME: E3.DWG DATE: 5/19/00 2:40 PM i w X FEEDER SCHEDULE AT&T BUILDING 0 2 [( 3 # 3/0 & 1# 1/OG ) 2" PVC] UTILITY CO. METER 400A 10, SERVICE DISCONNECT SWITCH AT&T Wireless Services © 2 [3 # 3/0 & 1#1/0 G) 2" C] 120/24OV, NEMA 3R OOA-2P, SN 120/240V SUITE C-1 ® (3 # 3/0 & 1# 2 G) 2" C NEMA 313 1001 16TH. STREET DENVER, COLORADO 60265-0003 CD (1 # 1/0 G) 3/4" C -- -- -- — -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- i MANUAL TRANSFER SWITCH C.T. CABINET 400A, 10 20OA-2P, SN, 120/240V 120/240V NEMA 3R I I NEMA 1 (FUTURE) 2 AT&T EQUIPMENT ROOM • r '0 -- -- I 0 -- ----- � 400A i� �— i I i , I zP 400AF I 3 1 Z ' �— SN DC -- --� — -- 3 I , I EXISTING UTILITY CO. PAD MOUNTED TRANSFORMER 300KVA, O 30, SEC.: 208/120V i I i i i I .� I i ' Architects — Engineers, P.C. 12250 East Iliff Avenue, Suite 302 MOBILE GENERATOR RECEPTICAL I —_ I l I \ I I Aurora, Colorado 80014-1253 200A, 3P, 4W, 120/240V, MALE 2 I , � I � I � I 303.750.6999 FAX 303.750.0236 I I I i � Email: kdcdenver®kdcarchitects.cvm . I NEMA 3R (FUTURE) I I I I Website• www.kdcarchitects.com UTILITY Co. V — --I----------------------� -------� --- ----� PRIMARY LINE � � O , i 4 4 I I 2 AT&T POWER PANEL "A" AT&T POWER PANEL °B° ( I AT&T WIRELESS SERVICES NEMA 1 �� 3W 200A, 10, 3W PROJECT i NEMA 1 (FUTURE) 2 3 (SEE PANEL SCHEDULE) 204033.003 MOBILE GENERATOR RECEPTICAL MANUAL TRANSFER SWITCH ' ' DRAVVN BY NEMA 3R, 4W,120/24OV, MALE 20OA-2P, SN, 120/240V I I FOR NEMA 1 , ' MKS • � + ISSUE 1 03.03.00 CLIENT REVIEW/ZONING Z 04.21.00 ZONING 3 0531.00 ZONING REVISION 4 06.19.00 ZONING REVISION 5 06.23.00 RF REVISION 6 06.27.00 ZONING REVISION 3 (:j)O NE-LINE DIAGRAM PANEL A SCALE. NONE POVER SUPPLY, 1201240V,10,4W ]RACING, 42000A RMS STM ENCLOSURE, NEMA 1 P00 RF(a� PANEL MAID MC]200A MOUNTING SURFACE %r ��.•'' H �� < PANEL BUST 225A O� LOAD BRANCH C/BREAKER CKTI LOAD OCVA) BRANCH C/BREAKER LOAD 8�C -'a�� r' DESCRIPTION PALES TRIP FRAME S 0 A 0 B ] FRAME TRIP POLES DESCRIPTION e 1.525:3 l 562 1 AHU-1 2 15A 100A 3 562— 562 2 100A 15A 2 AHU-2 562 4 NOTE: GENERAL NOTES: �' - 5 3338 2 GOA 1MA 3338 3338 6 1MA 60A 2 CU-2 POWER AND TELCO TO BE 3338 B 0 All drowin s and written material contained COORDINATED WITH OWNER herein mar not be duplicated used or disclosed 1. ALL NEW WIRING SHALL BE COPPER WITH 9 1440 __ 10 without the written consent of the architect. AT&T PROJECT MANAGER AND INSULATION RATED 60OV, 90'C, RECTIFIER a1 2 30A 1ooA ll -- 1440 1ooA 30A 2 RECTIFIER 4 UTILITY COMPANIES 1440 12 2. TOTAL LENGTH OF FEEDER� SHALL NOT 13 1440 -- EXCEED 25 FT. RECTIFIER R2 2 30A 1DaA 15 1440_ 1440 14 1IIA 30A 2 RECTIFIER 45 SITE I INFORMATION 1440 16 KEY NOTES 17 1440 __ RECTIFIER R3 2 30A IOOa 19 1440_ 1440 19 lOOA 30A 2 RECTIFIER 16 WEST VA I L 1440 20 OEXISTING UTILITY CO. PAD MOUNTED TRANSFORMER © ENVIRONMENTAL CONTROL PANEL 1 20A IMA 21 200 —__ RECEPTACLES 300 KVA, 30, SEC.: 208/12OV. 1 2oa looa z3 900— 640 M IOOA MA 1 DUAD RECEPTACLE 2077 N. FRONTAGE RD. LIGMX 360 24 IOTA 20A 1 VAIL, COLORADO 81657 O FUTURE EQUIPMENT AND WIRING TO BE INSTALLED © SMOKE DETECTOR 1 20A loos 25 12 _ EXHAUST FAN UPON EXPANISION NEEDS 1150 — 26 1mA 2oA 1 1 2oA M13A 27 --- ❑ ;'� ESTABLISH SERVICE GROUNDING CONDUCTS TO BE SPACE 60 29 1mA 20A I TOR L ,. O SPACE CONNECTED TO EXTERIOR GROUND RING AND COLD 1 2llA 1DOA H ___ 30 1 SPACE WATER SERVICE PIPE. SPACE 1 20A IODA 31 --- 32 1 SPACE D SPACE L 20A 1130A 33 —_ 34 1 SPACE LOAD STUDY' SPACE 1 2oA 1®a EXISTING PEAK DEMAND LOAD IN THE BUILDING, FOR 35 36 1 SPACE THE LAST 12 MONTHS, IS 45.6 KVA. SPACE 1 20A mOA 37 38 1 SPACE ROOF-TOP ANTENNAS & MAXIMUM NEW DEMAND LOAD TO BE ADDED BY AT&T SPACE 1 20A 10A 341 40 1®A 2llA 3 SURGE ARRESTER 10 EQUIPMENT IS: SPACE EQUIPMENT ROOM --- z 400A x 0 8 x 208V = 66 6 KVA 4 TOTAL CONNECTED LOAD PER PHASE(KVAa 17540 17500 PANEL DEMAND LOAD(KVAb 35040 SO, TOTAL NEW DEMAND LOAD ON THE UTILITY CO. TRANSFORMER PANEL TOTAL CONNECTED LOAD(KV0 35040 PANEL DEMAND LOAD(A) 146 IS 45.6 KVA + 66.6 KVA = 112.2 KVA. EXISTING UTILITY CO. TRANSFORMER IS 300 KVA. PANEL DEMAND LOAD CALCULATIONS, LOAD CONNECTED KVA DEMAND FACTOR DEMAND KVA REMARKS ELECTRICAL SUMMARY: UTUILITY CO. TRANSFORMER CAPACITY IS ADEQUATE TO LIGHTING 640 100 X 640 CARRY ADDITIONAL AT&T EQUIPMENT LOAD. RECEPTACLES 1260 IDO 7. 1260 L © -INDICATES C/BREAKER LICKING DEVICE AND ABBREVIATIONS MOTORS 15768 100 x 15768 2. INSTALL ISOLATED GROUND BUS KIT OTHER 17312 100 7. I7372 NOTES, SYMBOLS LIST SPECIFICATION SHEET? NUMBER 2 PANELBOARD SCHEDULE SCALE: NONE 4 DWG NAME: E4.dw DATE: 5/19/00 2:40 PM u ALARM NOTES 1. ALL ALARM WIRING SHALL BE #22 AWG. R,- 6"x 6"x 4" NEMA 1 ENCLOSURE WITH SOLID WIRE (RED/BLACK) INSULATED, AT&T DOOR MOUNTING PANEL FOR RELAYS, NON–SHIELDED CABLE. TYPE HOFFMAN #A-6N64/A-6N6P 2. ALARM CABLING FROM RIGHT–HAND SIDE OF M66-100 BLOCKS TO INTERFACE EQUIPMENT WILL BE PROVIDED AND INSTALLED BY USER. 0--- AT&T Wireless Services _ 1 1 SUITE C-1 3. NORMALLY OPEN (N/0 ALARMS WILL 1001 16TH. STREET CLOSE ON ALARMED C DITION. (3 2 DENVER, COLORADO 80265-0003 #22) 1/2"C NORMALLY CLOSED N C WILL -------0 0 0 0 �(2 TO EXTERNAL ALARM OPEN ON ALARMED N ITION. –_-3– } PANEL PINS 27 & 28 HIGH TEMPERATURE 0 4 ALAR M ---5- �� ■ THE WIRED HIGH NORMALLY CLOSED. I I ----- 0 0 0 0 i ALARM CONTACTS ARE I N/C 6 RELAY–SPDT RELAY–SPDT A TEMPERATURE INCREASE I TT 7 ® ® ■ , 120 VAC COIL 120 VAC COIL RISE) TO 85'F WILL I I _____ RELAYS SHALL BE OPEN DRAWING CONTACTS. I W 120 120 8 OMRON RELAYS � I I O—— ——-1 #MJIPUAAC120 0 9 W/ SOCKET RED TO PINS – --°– , - - - - - - LOW TEMPERATURE 11 & 12 - 10-- ALAR M __ _- - BLK -0 .. H1 NEUTRAL H2 THE LOW TEMPERATURE 1 ALARM LK 0 11 ALARM CONTACTS ARE I I N/C ------ WIRED NORMALLY CLOSED. I I 1 01 RED TO PINS RED A TEMPERATURE DECREASE 1 1 13 & 14 LO TEMP 3_ OFPEN)THOE CONTACTS. I BLK ALARM BLK 14 " . POWER FAILURE RELAY SEE DRAWING M-1. 1 RED TO PINS DOOR ALARM RED 15 SCALE: NONE N ROOM 15 & 16 EQUIPMENT gLK DOOR ALARM BLK ROOM) Q�__ 16– THE CONTACTS FOR THE MAGNETIC 0 17 DOOR ALARM ARE WIRED NORMALLY ------- CLOSED. WHEN DOOR IS CLOSED, 0 18 CONTACTS WILL CLOSE. WHEN DOOR "" Architects – Engineers, PC IS OPENED, CONTACTS WILL OPEN. ® 19 VERIFY WIRING OF DOOR ----- 12250 East Iliff Avenue, Suite 302 ALARMS W/ JOEL HUMKE (303) 349-7957 0 20 Aurora, Colorado 80014-1253 2#12&1#12G)1/2( "C 303.750.6999 FAX 303.750.0236 21 Email: kdcdenver®kdcarchitects com T.O.S. (TECH ON SITE) SWITCH 0--22 Website: www.kdcarchitect3.com HH ------- N TO PANEL "A" 0_– 23– N (SEE PNL. "A" SCHEDULE 0 24 AT&T WIRELESS SERVICES G ON DWG. E-1) -- 25 PROJECT G ----- (2#14)1/2"C POWER FAILURE ALARM 0 26 204033003 MID A 240 VAC RELAY IS INSTALLED ACROSS RED /7�–=27 � DAMPER ALL PHASES OF INCOMING COMMERCIAL RED TO PINS gACC FAIL �– --- DP A 1k POWER. UPON POWER LOSS, A SET N/C 27 & 26 COMMERCIAL BLK HYDROGEN GAS DETECTOR OF NORMALLY CLOSED CONTACTS WILL BLK POWER ------ OPEN, GIVING AN ALARM. -- MACURCO, INC. CAT.# HD-21-1–BR (2) 29_ MKS 30 • R I (2#12&1#12G)1/2"C COMMON —-- 44 1 03.03.00 CLIENT REVIEW/ZONING TO PIN 45 45 COMMON 2 04.21.00 ZONING R TO PIN 46 � 46 FUSE FAILURE OIL I 1 FUSE FAILURE 3 05.31.00 ZONING REVISION — — H UNDER VOLTAGE ------- 4 0619.00 ZONING REVISION i TO PIN 47 +24 VDC 47 UNDER VOLTAGE 5 06.23.00 RF REVISION i I I RECTIFIER FAILURE RECTIFIER – ----- 6 06.27.00 ZONING REVISION L---------J I I 1 1 N TO PANEL "A" MAINS FAILURE TO PIN 48 ALARMS _--_ 48– RECTIFIER FAILURE M (SEE PNL. "A" SCHEDULE TO PIN 49 –_ 49– MAINS FAILURE 1 I 1 1 ON DWG. E-1) OVER VOLTAGE TO PIN 50 ® 50 VER VOLTAGE G +24 VDC RECTIFIER ALARMS M1-50 BLOCK #1 EXHAUST FAN ALL +24 VDC RECTIFIER ALARM CONTACTS pO REG� ARE NORMALLY OPEN. A FAILURE WILL RELAY WITH 120VAC COIL CLOSE THE CONTACTS FOR THE RESPECTIVE ALARM. THESE ALARMS AND AN 8–PAIR 1525-3 SWITCH WITH THERMAL OVERLOAD COMMUNICATION CABLE WILL BE PROVIDED 1 N.O. CONTACT RATED 20A, 120VAC (INDUCTIVE LOAD) AND INSTALLED BY LUCENT. 51 COMMON ENCLOSURE: NEMA 12 0 52 MAINS FAILURE ` /oNAL�'`G\''� 53 FUSE FAILURE ® AII drawings and written material contained EXHAUST FAN CONTROL DIAGRAM -- 54 OVER VOLTAGE herein may not be duplicated used or disclosed 2 RED TO PINS SMOKE RED � 55 without the written consent of the architect. SCALE: NONE SMOKE DETECTOR ALARM N/C BLK 55 & 56 DETECTOR BLK ® 56 ALARM ----- ORMATION DC DISTRIBUTION FAIL ALARM 0 _ 57 OPEN OF URINGRAN ALARMED CLOSED CONTACTS WILL RED 59 &l 60 --58— WEST VAI L INDICATING A LOSS OF DC BATTERY E/C BLK DC DISTRIBUTION RED 0 59 WILL BE DISTRIBUTION POWER TO THE INSTALLED BY LUCENT. FAIL ALARM �B:L:K: --60_ 2077 N. FRONTAGE RD. 0 61 VAIL, COLORADO 81657 62 SURGE ARRESTOR ALARM RED (2) RED TO PINS SURGE 63 A SET OF NORMALLY CLOSED CONTACTS 63 & 64 ARRESTOR ALARMED CONDITION, (EN/C BLK (EEM BLK 0----–6-4 INDICATING AFAILURE RARR SOR. (SEE – o ® 65 0 65 x 0 67 ROOF—TOP ANTENNAS 8c 0--68_ EQUIPMENT ROOM SPARES RED TO PINS RED 0 69 THESE ALARM POSITIONS ARE NOT USED AND (DK/CBLK:69 & 70 SPARE BLK 0 70 ARE PRESERVED FOR SPARES. THESE ARE ______ DETERMINED BY THE CUSTOMER AND THE RED OPTIONS WHICH ARE REQUIRED. ALL ALARMS RED TO PINS SPARE 0--71– SHEET ,TITLE SHOULD BE WIRED NORMALLY CLOSED. 71 & 72 BLK /7t 72 FAILURE SHALL INDICATING ATING ANALARMECON TIONNTACTS, N/C BLK 0--23 DETAILS AND PINS 73-100 0 _ 74 DIAGRAMS ARE NOT 98 UTILIZED �----- 99 0 100 SflEET� NUMBER, M66-100 BLOCK #2 3 EXTERNAL ALARM PANEL SCALE: NONE 5 DWG. NAME: E5 DWG DATE: 5/19/00 2:40 PM I 4 TO WAVE GUIDE LOCATED AT CHASE. ROUTE TO ANTENNA GROUND BUS. CONDUCTOR ATTACHED TO COMMUNICATIONS SEE DETAIL B/E-4 CABLE SUPPORT RADIO EQUIPMENT GROUND BUS a • • • O O O O WALL—x M"OUl2" LID+COPPER O SECURE TO WALL WITH APPROVED INSULATORS PLAN VIEW O O O o ONE HOLE CRIMP CADWELD OR AT&T Wireless Services SUITE C-1 LUG TO EXISTIN CABLE TO PIPE CONNECTOR 1001 16TH. STREET 0000 SCREW BURNDY TYPE GAR DENVER, COLORADO 80265-0003 #2 TH GREEN GROUND CONNECTOR NN CTOR C. 0 0 0 0 Q SPACING AS SHOWN (TYP. FOR 2 PLACES) 1 4" x4" x12" SOLID COPPER ON DWG. ® ® MOUNTED AT ANTENNA LOCATION O 0000 0 1 11 1 11 F #2 TO HALO GROUND o o O o SEE PLAN 3/E-2 #2 COPPER GROUND WAVE GUIDE AT TENANT SPACE 2 AWG CONDUCTOR # BCW --� A#a CONDU GREEN TO (RADIO EIQUIPMENT 4" #6 AWG. STRD. CU I I_ MASTER GROUND BAR GROUND BUSBAR WALL—x4" x6" SOLID COPPER TWO HOLE CRIMP LUG 0 WALL— MOUNTED A.F.F. +96 . 3/8 BOLT, NUT & O SECURE TO WALL WITH APPROVED WASHER O O RADIO EQUIP. GROUND BUS • . INSULATORS. SEE E/E-4 FOR O INFORMATION O O ELEVATION #2 AWG. SOLID 1 2" PVC PENETRATE WALL WALL ROOF FEED THRU ASSEMBLY CU. BARE TINNED SEAL WITH CALKING AS REQD ANDREW 204673-1, COAX BOOT 3 0 COPPER INSULATED GROUND CONDUCTOR I 1" GRS TO COLD WATER PIPING. TO MASTER GROUND BAR IZE AS READ PER COAX SIZE �TYP. 1 PER COAX ENTRY) ANTENNA GROUNDING AT INTERNAL GROUNDING DETAIL B C ANTENNA GROUND BUS WAVE GUIDE ENTRY PLATE GROUNDING SCREENED WALL (ONE SECTOR SHOWN) KDC A Architects — Engineers, PC SCALE: N.T.S. SCALE: NJ S. SCALE. NJ S. 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 "N" SECTION Email- kdcdenver@kdcarchitects.com "A" SECTION (NON—IGZ Website: www.kdcarchitects.com (__SURGE EQUIPMENT) ARRESTER) LEGEND "" IGZ ISOLATED GROUND ZONE AT&T WIRELESS SERVICES "P" SECTION I SECTION PROJECT TO OTHER SURGING ( MDF MAIN DISTRIBUTION FRAME SURGE i i i IGZ EQUIPMENT MGB MASTER GROUND BAR GROUND BARS PRODUCERS) i CONNECTED VIA MGN MULTI—GROUND NEUTRAL IGB 204033 003 STAND—OFF INSULATOR :DRAWN DP ® CHECKED BY ' o o 0 µ MKS i NOTE NO, ■ Q i i i 1. ALL "A" AND "I" SECTION WIRES ARE STANDARD. GREEN INSULATED #2AWG. 4f 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING 2. "N" SECTION: USE BARE #2 AWG FOR IGR (HALO) WIRE. 3 05.31.00 ZONING REVISION TO MDF PROTECTOR O I O I ® i Q Q 3. "P" SECTION WIRES ARE GREEN INSULATED #6 AWG (MIN.) 4 0619.00 ZONING REVISION GROUND BAR i i i . 4. USE LUGS APPROPRIATE TO WIRE SIZE AND TYPE: 2 HOLE 5 06.23.00 RF REVISION TYPE REQUIRED WHERE SHOWN, PREFERRED ELSEWHERE. ; 6 06.27.00 ZONING REVISION 5. ROUTE TO 1" OR LARGER C.W. PIPE. LTC BUILDING STEEL OR REBAR " TO IGZ-2 �.o0REG� (TO CELL SITE EQUIPMENT) TO COLD WATER PIPE NOTE 5 e`• fy,a TO POWER SUPPLY TO IGZ-1 TO MGN "AC AC GREEN WIRE EXOTHERMIC WELD ����� (AT ENTRY PANEL) -oe TO BUILDING GROUND s'-----• -Gta�' A [: S�ONA\-" MASTER GROUND BAR CONNECTIONS NOT USED NOT USED ®AII drawings and written material contained E G herein may not be duplicated used or disclosed without the written consent o the architect. s SCALES N.T.S. SCALE: N.T.S. SCALE: N.T.S. • ' • 2 PANEL "A" WEST VAIL SURGE ARRESTER KEY NOTES _ _ _ SURGE ARRESTER GENERAL NOTES 2077 N. FRONTAGE RD. MAIN 200A C2PB VAIL, COLORADO 81657 OSURGE ARRESTER: JOSLYN ELECTRONIC 1. SURGE ARRESTER SHALL BE CONNECTED TO THE # 1455-85, 120/208V-30. (OR APPROVED EQUAL) L1 I I I I MAIN C/BREAKER OF PANEL "A". 2 MANUAL TRANSFER SWITCH. (�A) I L1 I I L1 2. GROUND BUS IN SURGE ARRESTER IS UTILIZED I 0 ONLY AS AN EQUIPMENT CASE GROUND. O E DESIGN O3 #22 AWG SOLID WIRE INSULATED, I I 3. WIRING FROM THE SURGE ARRESTOR TO THE MANUAL TRANSFER SWITCH SHALL BE #4 AWG, .t NON—SHIELDED CABLE, 1/2 C. TO EXTERNAL I ALARM PANEL PINS 63 & 64. L2 THW (MINIMUM) OR AS SPECIFIED BY THE SURGE ARRESTER MANUFACTURER. O (4 #310 CU + 1 #4 CU GND) TO SERVICE (OB) I L2 I I L2 0-- 4. ALL CONDUCTORS SHALL BE FANNED OUT ROOF—TOP ANTENNAS r� 2" DISCONNECT EMT CONDUIT SWITCH I I I SMOOTHLY. NO RIGHT ANGLE BENDS ARE EQUIPMENT ROOM O PERMITTED. CONNECT ALL LEADS A,B,N,G, 4 #4 AWG THW (MINIMUM) INSULATED COPPER WIRE 208/120V TOGETHER SO THAT THEY WILL BE IN CLOSE + (SEE NOTE #3). CONNECT CONDUCTORS TO LOAD `" PROXIMITY TO EACH OTHER. LENGTH SHALL SIDE STUDS WITH BLACKBURN #GTL-516 OR EQUAL LUGS. N SN N 5N BE AS SHORT AS POSSIBLE BUT NO LONGER THAN 8 FEET. SHEET TITLE 6 4 # 6 ) 3 4" C. I I I 5. SHOULD ADDITIONAL INFORMATION BE REQUIRED, SEE NOTE #3 . CONNECT CONDUCTORS TO LOAD CONTACT JOSLYN ELECTRONIC SYSTEMS DIVISION, SIDE STUDS WITH BLACKBURN #GTL-516 OR EQUAL LUGS. GND I GND GND ( I GND SANTA BARBERA RESEARCH PARK, BOX 817, GOLETA, CALIFORNIA 93017 (805) 968— 3551. DIAGRAMS DETAILS AND 4 6 GND N L1 L2 �SHEET NUMBER 1 N G1O 3 TO PORTABLE 2 ,� - GENERATOR RECEPTACLE 3 SURGE ARRESTER DIAGRAM NOT USED 6 SCALE: N.T.S. SCALE: N.T.S. DWG. NAME: E6.dw DATE: 5/19/00 2:40 PM dtl u r A FINISHED GRADE AT&T 0 o E � s 2 N 00000 Z TWO HOLE CRIMP AT&T Wireless Services LUG TO EXISTING SUITE C-1 WARNING TAPE - SCREW 1001 16TH. STREET 0 ° ° ELECTRICAL AND ALARM CONDUIT `� o DENVER, COLORADO 80265-0003 0 ° ° o 0 PRIMARY GROUND BAR DETAIL (PLACE WARNING TAPE 2 BELOW FINISHED �' 0000 o ° o ° o GRADE ONLY WITH FIBER OPTIC CONDUIT) '� o CRIMP LUG TO " " o ° ° ° o ° REFER TO 4/E-5 0 0 0 0 0 0 0 ° o ° o o ° #2 AWG SOLID CABLE. o MOUNTED AT ANTEENNA LOCATION 0 0 0 GROUND ELECTRODE WAVEGUIDE HATCH 0 0 0 0 �-- #6 AWG STRD. CU ® � � ■ � #2 COPPER GROUND CONDUCTOR FUEL LINES TWO HOLE CRIMP LUG ° WITH GREEN INSULATION IN 3/4" NOIL25s 3/8" BOLT, NUT & WSHR. ° o GROUND TO RADIO EQUIPMENT 1) COPPER GROUND BAR OR APPROVED EQUAL, EXTERNAL GIRD. BAR MTD. 1/4" x 4" X 24". HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION. 4" (SCHEDULE 80 PVC — REGEN FIBER #2 AWG SOLID CU._-­, BELOW BELOW HATCH PLATE 2 SPACERS AS REQUIRED OPTIC CONDUIT) BARE TINNED. TO EXTERNAL 3 5/8" LOCKWASHERS 4) WALL MOUNTING BRACKET RING GRD. RING 5) 5/8" —11 x 1" H.H.C.S. BOLTS 6) GROUND BAR TO BE SUPPLIED WITH EQUIP. SHELTER A TYPICAL GROUND BAR STANDARD BURIAL DEPTHS WAVEGUIDE HATCH GROUND ANTENNA GROUND BUS KDC C C D Architects — Engineers, P C. SCALE N.T.S. SCALE: N.T.S. SCALE: N T.S. SCALE: N.T.S. 12250 East Iliff Avenue, Suite 302 i Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 Email: kdcdenver®kdcarchitects com TO ANTENNA GROUND BUS. Website: www.kdcarchitects.com CABLE GROUND KIT SEE DETAIL B/E-4 PROJECT NUMBER FROM ANTENNA W RE STRANDED COPPER TO GROUND BARD RX STANDARD ANDREW (STANDARD ANDREW GROUNDING KIT) GROUND KIT " L I (rn') ANTENNA " " " SOLID CO PER AT&T WIRELESS SERVICES JUMPER 1/2 (TYP) CABLE 0 0 0 0 ----� WALL x MOUNTED AT +84 . ANTENNA COAX CABLE _ _ TO ANTENNA i IX L____ ® ® INSULATORS :04033003 . ANTENNA o 0 0 o pp 3 3/4"_ 6" ----, CABLE NO SHARP BENDS VX. DIA. 12 APPROX. L A #2 COPPER GROUND CONNECTOR MKS INSIDE WALL OF BUILDING CONNECTOR WITH GREEN INSULATION IN 3/4 C. DATE ISSUE COLD SHRINK #6 AWG LADDER WEATHERPROOFING KIT (TYP) STRANDED COPPER 1 03.03.00 CLIENT REVIEW/ZONING AT ANTENNA GPS CABLE END WIRE 2 04.21.00 ZONING III SEETPLAN L3/ER�UND 3 05.31.00 ZONING REVISION CABLE GROUND KIT DOUBLE HOLE 4 06.19.00 ZONING REVISION #6 AWG STRANDED COPPER GROUND CONNECTORS (TYP) 5 06.23.00 RF REVISION WIRE (GROUNDED TO GROUND BAR} �— 6 06.27.00 ZONING REVISION (STANDARD ANDREW GROUNDING KIT) �_ MASTER GROUND BAR GROUNDING BAR #2 AWG BCW—(CONTINUOUS) TO TRANSITION WALL—x4" x6" SOLID COPPE ON T.O. MONOPOLE GIRD ROD AT BASE OF 0 WALL— MOUNTED A.F.F. +96R. ON ISOLATERS MONOPOLE TO ANTENNA SECURE TO WALL WITH APPROVED ANTENNA " — ® INSULATORS. SEE E/E-4 FOR Pp0 R G` rs COAX CABLE 2° 6 INFORMATION 12" APPRO_X.I 0 0 �aao 15253 9a 3/0 COPPER INSULATED GROUND CONDUCTOR AT ANTENNA CABLE END IK 1" GRS TO COLD WATER PIPING. m " NOTE: DO NOT INSTALL CABLE GROUND KIT AT A BEND 1Q A�_ TYPICAL CONNECTION AT ANTENNA TYPICAL ANTENNA GROUND TO INTERNAL GROUNDING DETAIL NOT USED { E F G m All drawings and written material contained > < > H CABLE END GROUND BAR (ANTENNA LEVEL herein may not be duplicated used or disclosed SCALE N TS SCALE: N T.S. SCALE N.T.S. SCALE. N.T.S. without the written consent of the architect. � SITE,: INFORMATION WEST VAIL =� 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 t ROOF-TOP ANTENNAS & EQUIPMENT ROOM SHEET TITLE GROUNDING DETAILS NUMBER r K NOT USED NOT USED L NOT USED M NOT USED 7 � _ SCALE N.T.S SCALE N.T.S. SCALE: N.LS SCALE: N.T.S. DWG. NAME: E7dwg JDATE: 5/19/00 2:40 PM AT&T WIR SS S RVIC S SITE N0 . 2 - 056 AT&T AT&T Wireless Services WEST VAIL SUITE C-1 „. 1001 ENVER, COLORADO 80265-0003 2077 N . FRONTAGE RD . VAIL , COLORADO 81657 ROOF - TOP ANTENNAS AND EQUIPMENT - • ROOM PROJECT TEAM PROJECT SUMMARY DRAWING INDEX - SYMBOLS PROPERTY OWNER SITE ADDRESS TITLE SHEET — — —— PROPERTY LINE T-1 TITLE SHEET JAYNE BRANDESS REVOCABLE TRUST 2077 N FRONTAGE RD. X X X X X FENCING 41 184 HWY 6 VAIL, COLORADO 81657 ARCHITECTURAL AVON, CO 81620 —E E E— ELECTRICAL SERVICE HOME PHONE- NA A-1 SITE PLAN WORK PHONE: (970) 949-1636 —T T T— TELCO SERVICE CONTACT BRIAN O'REILLY A-2 FIRST FLOOR PLAN 61 Nor CODE BLOCK A-3 EQUIPMENT ROOM AND DEMOLITION PLAN , APPLICANT SITE LOCATION- 2077 N FRONTAGE RD ti' (N) NEW Architects — Engineers, PC A-4 CONSTRUCTION, FINISH, AND CEILING PLANS 12250 East Iliff Avenue, Suite 302 VAIL, COLORADO 81657 (E) EXISTING Aurora, Colorado 80014-1253 303 750 6999 FAX 303.750 0236 AT&T WIRELESS SERVICES A-5 ROOF PLAN Email kdcdenver @kdcarchitects com SUITE C-1 JURISDICTION• TOWN OF VAIL 4, DETAIL REFERENCE SYMBOL Website. www kdcarchitects.com •'�'� XXX 1001 16TH. STREET 75 S. FRONTAGE RD. A-6 ELEVATIONS DENVER, COLORADO 80265 VAIL, CO. 81657 A-3 (303) 573-3277 (970) 479-2100 :t A-7 ARCHITECTURAL DETAILS CONTACT- JEFFREY W RINEHART AT&T WIRELESS SERVICES A-8 DUMPSTER CORRAL SITEPLAN Al2 ELEVATION REFERENCE SYMBOL PROJECT, NUM: - BUILDING CODE 1997 UNIFORM BUILDING CODE APPLICANT AGENT 1996 NATIONAL ELECTRIC CODE A-9 DUMPSTER CORRAL FLOORPLAN & ELEVATIONS 2101020 003 PROPOSED EQUIPMENT OCCUPANCY- U 2 S - ' A-10 DUMPSTER CORRAL FOUNDATION PLAN BUILDING SECTION & DETAILS q_2 PLAN REFERENCE SYMBOL WALKER COMMERCIAL (UNMANNED TELEPHONE EQUIPMENT AND ANTENNA) BW 7354 S. EAGLE ST ® V ENGLEWOOD, CO. 80112 ' WATER SUPPLY- NONE/WASTE WATER: NONE/PLUMBING- NONE f' STRUCTURAL O KEYED NOTES ' TEL- (303) 680-6600 ° S-1 MKS SCREEN FRAMING DETAIL ® FAX (303) 680-2179 ELECTRICAL: PUBLIC SERVICES r— n l • � CELL 303 905-4444 ® GROUND ROD WITH ACCESS ( ) TELEPHONE- U S WEST z,r S-2 SCREEN SECTIONS AND DETAILS,. 1 C�� q CONTACT- RALPH WALKER 2 THE PROPOSED PROJECT INCLUDES S-3 DUMPSTER CORRAL FOUNDATION PLAN AND SECTION 0 ,�.,, ® XIT GROUND ROD 3 �� L O 4 CONSTRUCTION MANAGER PROVIDE AT&T EQUIPMENT ROOM IN EXISITNG BUILDING ', S-4 DUMPSTER CORRAL FLOOR PLAN AND ELEVATIONS ® GROUND ROD 6 CONSTRUCTION TO BE ONE HOUR RATED. ; M ' AT&T WIRELESS SERVICES MECHANICAL I CAL M-1 MECHANICAL DETAILS, NOTES AND SCHEDULES ,' OJ DISCONNECT SWITCH 8 SUITE C-1 9 . INSTALLATION OF AT&T ANTENNAS ON ROOFTOP � � 1001 16TH. STREET - '�� M-2 MECHANICAL PLAN �;. � METER ON METER/ BREAKER UNIT � 040 DENVER, COLORADO 80265 303 881-7386 3 SECTORS/ 4 ANTENNA PER SECTOR/ 12 TOTAL; 1 OMNI ANTENNA, `r A, ( ) ELECTRICAL � o CONTACT: DON WILL � CIRCUIT BREAKER ENNSW "r COAXIAL CABLE RUNS FROM ANTENNAS TO EQUIPMENT ROOM; E-1 ELECTRICAL SPECS, NOTES, SYMBOLS, ABBREVIATIONS, AND ELECTRICAL SITE PLAN ARCHITECT ENGINEER A NEW TELEPHONE SERVICE RUN TO THE EQUIPMENT ROOM, E-2 DEMOLITION PLAN G N < 8-1139 c'` e , � GENERATOR i� Il�y��p � r KDC ARCHITECTS.ENGINEERS, P.C. ANEW 400A ELECTRICAL SERVICE TO THE EQUIPMENT ROOM, E-3 POWER, LIGHTING, GROUNDING PLANS, AND NOTES 12250 E ILIFF AVE SUITE 302 CADWELD TYPE CONNECTION J E-4 ONE—LINE DIAGRAM PANEL SCHEDULE AND NOTES ern m All drawings and written material contained AURORA, COLORADO 80014 AT&T PROJECT AREA IS APPROXIMATELY 960 SQUARE FEET } herein may not be duplicated used or disclosed (303) 750-6999 - without the written consent of the architect. (303) 750-0236 FAX E-5 DETAILS AND DIAGRAMS ® COMPRESSION TYPE CONNECTION ken.comp @kdcarchitects.com LAT 39'37'59.2"N E-6 a ` DETAILS _ • - o CONTACT- KENNETH D CAMP LONG 106'24'48.8"W — —— —————— GROUND WIRE E-7 DETAILS WEST VAI L 2077 N. FRONTAGE RD. LEASE AREA DESCRIPTION APPROVALS VI C1 ITY MAP NO SCALE DIRECTIONS TO SITE VAIL, COLORADO 81657 SITE PARCEL NO.: TAKE 1-70 WEST TO VAIL, TAKE WEST VAIL EXIT #173, PROCEED EAST SITE NAME: WEST VAIL PAST CITY MARKET TO BRANDESS BUILDING AT 2077 N. FRONTAGE RD. WEST. LEGAL DESCRIPTION: AT&T APPROVAL ".= LEGAL DESCRIPTION — ENTIRE PARCEL a LOT 39, RESUBDIVISION OF BUFFER CREEK, COUNTY OF DATE EAGLE, PSQ�� — � i� ROOF TOP ANTENNAS & STATE OF COLORADO, EXCEPT DEPARTMENT OF HIGHWAYS, REAL ESTATE APPROVAL , f EQUIPMENT ROO M STATE OF COLORADO, PARCEL NO. 16 REV 2, PROJECT NO 1 70-2(7)1 B3,ACCORDING TO CIVIL ACTION NO 1481 IN THE P y� DISTRICT COURT IN AND FOR THE COUNTY OF EAGLE, �.��� STATE OF COLORADO CONSTRUCTION APPROVAL DATE S�`PMo� 70 Tom O SHEET TITLE opy DATE SITE RF APPROVAL ���� — O 197 TITLE SHEET LANDLORD APPROVAL DATE A NOV o 8 zou � o =x, DATE .D►EV. NUMBER EQUIPMENT ENGINEER APPROVAL NORTH rF DATE NTS 24445-7DE-2056—T01-9 r AT&T AT&T Wireless Services / _ 1001 16TH STREET DENVER, COLORADO 80265— 0003 A O\ // 0 �OP� l \ \ TELE. PED K C _ T / �'S5� , \ T ---- T Architects — Engineers, P C ' 12250 East Iliff Avenue, Suite 302 1A Aurora, Colorado 80014-1253 O / S 303.750 6999 FAX 303.750.0236 / \ , 6, \ \\ Email kdcdenver@kdcarchitects com Website. www.kdcarchitects.com AT&T WIRELESS SERVICES PROJECT--NUMBER Y �`,F 2101020 003 , / \ �o�� � � i ��, � � \ -40�e< U DP \ \ 11p \ i \ MKS \--2'x3 3' INLET iNO DATE RAN J P Q / 1 03 03 00 CLIENT REVIEW/ZONING 2 0421.00 ZONING Q p / 3 05.31.00 ZONING REVISION \ \ N RIS \ \ \ '� STAIRWELL ��' h� OAF, 4 06 1900 ZONING REVISION 5 06 23 00 RF REVISION WV .g1 6 06 27 00 ZONING REVISION 0711 00 OWNER REVISION 10.1900 CONSTRUCTION/REVISION 11.07.00 CONSTRUCTION/REVISION DUMPSTER \\ \\� ' ,' \v \v � �� O� C040'p 6' HIGH CEDAR FENCE/ DUMPSTER, ENCLOSURE op. s� \ O Q\ �v / F QP/ KE AM W/ DBL 12' GATE P / „5°� B-1139 ® All drawings and written material contained herein may not be duplicated used or disclosed moo, \ FH without the written consent of the architect \ Y F�c F \ wv �y . P�� WEST VAI L \ �C) <O 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 PLATTED = 00 003'13” ZZ R= 5910. 00' ROOF-TOP ANTENNAS & L= 5. 53' EQUIPMENT ROOM CHD= S47 021 '15 W P&M = 5. 53' N37°15'30 W � SHEET TITLE MEASURED 0.90' = 00°01 '31 " R= 5910. 00' L= 2. 61 SITE PLAN CHD= S47 002'03"W 2. 61 ' NUMBER SHEET 1 SITEPLAN SCALE. 1"=15'—O" 24445-7DE-2056—AO1-9 J } b mom AT&T Wireless Services SUITE C-1 1001 16TH. STREET DENVER, COLORADO 80265-0003 KDC I I 1 A-3 Architects — Engineers, P.0 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303 750.6999 FAX 303 750 0236 Email. kdcdenver @kdcarchitects.com Website• www.kdcarchitects com I EXISTING WALLS TO 2 3 4 5 6 7 8 9 10 AT&T WIRELESS SERVICES I I BE REMOVED E) 2101020 003 - � EXISTING TRANSFORMER Cl MET 0 BM".YA MKS I I ISSUE PROPOSED AT&T � � ® EQUIPMENT ROOM 1 03 03 00 CLIENT REVIEW/ZONING SUITE B I STORAGE I I 2 0421 00 ZONING SUITE A BRANDESS RET IL AND PROFESSIONAL BUILDING 3 05 31 00 ZONING REVISION 4 06.1900 ZONING REVISION 5 06.2300 RF REVISION 6 06 27 00 ZONING REVISION 0711 00 OWNER REVISION DUMPSTER I 8 10.19.00 CONSTRUCTION/REVISION � 9 11 O� � wNSTRUCTION/REVISION 6' HIGH CEDAR FENCE/ C OCO DUMPSTER ENCLOSURE I I �P �O W/DBL 12' GATES _ B — — r KE'MNEI CAMP ELECTRICAL I I I A EXISTING BEAM m All drawings and written material contained FURRED OUT T_� E XISTING CONCRETE SIDEWALK herein may not be duplicated used or disclosed without the written consent of the architect INFORMATION-0 I EXISTING COLUM I WEST VAI L A - 2077 N. FRONTAGE RD. PROPOSED WALL 1 HR RATED VAIL, COLORADO 81657 CONSTRUCTION I PROPOSED WALL 1 HR RATED CONSTRUCTION EXISTING CMU WALLS ROOF-TOP ANTENNAS & ( EQUIPMENT ROOM 2068 WOOD DOOR & JAMB W/ LEVER HANDLE HARDWAREI SHEET TITLE EXISTING PARKING — PROVIDE WINDOW BLINDSI TO MATCH SUITE "B" FIRST FLOOR PLAN SHEET NUMBER I FIRST FLOOR PLAN 1 SCALE• 3/16" = 1'—O" 24445-7DE-2056—A02-9 INSTALLATION KEYED NOTES 0 PROVIDE AND INSTALL VERTICAL CHASE. REFER TO 7/A-7. 12" MAXIMUM Ulm 0 A/C UNITS—SEE MECH DINGS 4'-0" FINISHED 0 PROVIDE AND INSTALL EXHAUST FAN AND DUCT AS PER MECH DWGS BLOCKING BETWEEN STUDS 2'—O" � ® PROVIDE AND INSTALL EXTERIOR WALL MOUNTED GENERATOR PLUG 0 —6 BEHIND GYP BOARD AT&T Wireless Services SUITE C-1 4' MINIMUM 1001 16TH STREET 0 PROVIDE & INSTALL WAVEGUIDE PLATES & PORTS FOR COAX CABLE TYPICAL DENVER, COLORADO 80265-0003 PENETRATION THRU WALL. REFER TO DETAIL 1/A-7. i,�i,�� © PROVIDE & INSTALL 3-5/8" METAL STUDS W/ 5/8" GYP. BD. EACH SIDE '�T�� ������ REFER TO DETAIL 9/A-6. ■ 00 00 AT&T i FINISHED FLOOR 1 7 C) < PROVIDE 3' X 6'-8" H.C. WOOD DOOR JAMS W/ LEVER HANDLE HARDWARE ° (TYPICAL) ° i ® N PROVIDE STAINLESS STEEL GRAB BAR, SEE 1/A-3. `� `v FACE OF WALL 0 INSTALL NEW 3'-6" X 7'-4" X 4" CONCRETE PAD FOR CONDENSER UNITS (TYPICAL) PROVIDE WINDOW TREATMENT BLINDS TO MATCH SUITE 'B' BLOCKING FOR REAR BLOCKING FOR SIDE ' WATER CLOSET GRAB BAR WATER CLOSET GRAB BAR <a> 2068 WOOD DOOR & JAMB W/ LEVER HANDLE HARDWARE HANDY-CAPPED GRAB BAR DETAIL 1 SCALE- N T S K C Architects — Engineers, P C DEMO KEYED NOTES Aurora,East l Avenue, Suite 302 Aurora, Coloradad o 80014-1253 303 750 6999 FAX 303 750 0236 1O WALLS AND DOORS TO BE REMOVED Email- kdcdenver@kdcarchitects corn Website. www kdcarchitects.com < REMOVE AND RELOCATE ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS FOR ALL ELECTRICAL DEMOLITION. 0 EXISTING DOOR TO REMAIN AT&T WIRELESS SERVICES PROJECT 2101020 003 -1 ., 3 Nlrframwl 1 1 2 3 MKS 1 GEN FUTURE 2 5 3 NO DATE ISSUE PLUG EQUIP 1 03 03 00 CLIENT REVIEW/ZONING D D 2 04.21.00 ZONING 3 0531.00 ZONING REVISION m I III I I I I I 4 06 1900 ZONING REVISION RESTRO M = 0 � ( I❑ N m I I I I I I 5 0623.00 RF REVISION X-FMR 8 I i F 6 06 27 00 ZONING REV ISION EXISTING 8" 1 07 11 DO OWNER REVISION CMU WALL i :!s 10.19 00 NSTRUCTION/R EVISION 8 -2 z o w " II I I I I I 9 11 �F 0 UCTION/REVISION J :C!5:) 1 � 1❑ I �� - - - - - L - �J❑ O ® / / / ' KE Z W Q CT "�1A CAB Z -� SUITE A j N ❑ SUITE A B-� 39 ti METER & o LL I I AT&T L I AT&T I oa V SERVICE I m I I- I❑ f ' I STORAGE 1 /T - ENTRANCE I 6 o L EQUIPMENT I�N I SUITE B / / EQUIPMENT �SEO ARAN N ROOM � I ❑ ROOM L -� L -- - - - - SUITE A A-6 I w � L SUITE A SUITE B m All drawings and written material contained O t I I herein may not be duplicated used or disclosed I � w � — I ( without the written consent of the architect I L Of I ¢N I 1 I II I J w IC I 5 -6 ISITENRINFORMATIOW _M_ + Q -LF M�=❑ L ❑ ' WEST VAIL DUMPSTER I X Q $I° I ° ❑ I I I - - - - - - z � .. 2077 N. FRONTAGE RD. _- c - - - - �- - - wa � — - - - - - - - - — c - - - - I-- - - ❑ - - - - - - - -- - - - - - VAIL, COLORADO 81657 EXISTING COLUMN I 'I� I EXISTING BEAM �`L I— J 2O >N FURRED OUT — I — — B — — —_ — ❑ _ — — — — — — — 14'-7" ° 14'-0" LL m I ELECTRICAL I 6 11 I ROOF-TOP ANTENNAS & ALARM I 3 I EQUIPMENT ROOM � SHEET TITLE i 1 II I I I 10 EQUIP RM- 1ST FLR I AND DEMO PLAN ISHEET NUMBER : I ► n 2 IPMENT ROOM - FIRST FLOOR E. 1/4" — 1'-0" DEMO PLAN 3 SCALE: 1/4" = 1'-0" 24445-7DE-2056—A03-9 G A INSTALLATION PLAN KEYED NOTES CONSTRUCTION PLAN GENERAL NOTES FINISH SCHEDULE KEYED NOTES REFLECTED CEILING GENERAL NOTES] 1O RADIO EQUIPMENT PROVIDED AND INSTALLED BY OTHERS (SHOWN FOR COORDINATION PURPOSES) 1. THE FACILITY IS AN UNOCCUPIED TELEPHONE EQUIPMENT FACILITY. 1 EXISTING WALLS—FINISHED NO MODIFICATION REQUIRED NEW WALL A) RADIO RACKS 1 THIS DRAWING IS FOR COORDINATION PURPOSES ONLY, REFER TO MECHANICAL ATaT B) RECTIFIERS — (1) PRIME, (2) COATS OF PAINT COLOR P-1 PPG #2761 FLINTSTONE AND ELECTRICAL PLANS FOR SPECIFIC INFORMATION B) CLOSED—CELL BATTERIES (NON GASSING TYPE) 2 THE NET AREA OF THE EQUIPMENT ROOM IS APPROX 276 SQUARE FEET ORUBBER BASE- ARMSTRONG—CHARCOAL GREY #14123, 4" COVE 2 FIXTURE AND EQUIPMENT ELEVATIONS ARE AS MEASURED FROM EXISTING WALL O18" WIDE CABLE LADDERS (7'-4" A.F.F.) SUSPENDED FROM STRUCTURE. 3 THE GENERAL CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK REFER TO DETAILS 4 & 5 A-6 BY OTHERS USING BEST SKILLS AND ATTENTION THE CONTRACTOR SHALL BE SOLEY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, O RESILIENT FLOORING: TARKETT CONCERT ARTFLEC' SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF VCT-2 #2221 OFF WHITE SOLO AT&T Wireless Services O HIGH/LOW TEMPERATURE ALARMS ADJACENT TO ENVIRONMENTAL THE WORK UNDER THE CONTRACT SUITE C-1 — CONTROL PANEL SEE MECHANICAL DRAWINGS AND ALARM PANEL SCHEMATIC. , REFLECTED CEILING KEYED NOTES 1001 16TH. STREET 4 PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS 4 A/C UNITS & ASSOCIATED PIPING: INTERIOR PAINT P-2 DENVER, COLORADO 80265-0003 4O GROUND BAR THAN 2—A OR 2—A1 0BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS EXTERIOR PAINT TO MATCH EXISTING OF THE PROJECT AREA DURING CONSTRUCTION O TELEPHONE BACKBOARD 4' x 8' x 3/4" TYPE "CD" FIRE RETARDENT TREATED 5 THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS OF THE SITE EXISTING CEILING TO REMAIN RELOCATE LIGHT FIXRURES AS REQUIRED PLYWOOD MOUNT VERTICALLY WITH BOTTOM 4" ABOVE RUBBER BASE. COVER AND NOTIFY THE PROJECT MANAGER OF ANY DISCREPANCIES BEFORE 1O TO ACCOMMODATE NEW CABLE TRAY LAYOUT. FRONT FACE WITH "FRP" FIBERGLASS REINFORCED PLASTIC PANEL COLOR- WHITE STARTING ANY WORK O SURGE ARRESTOR SEE ELECTRICAL DRAWINGS 6. KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, O 2'x4' LAY—IN CLG. @ 9'-0" A.F.F. RUBISH AND REMOVE EQUIPMENTNOT SPECIFIED AS REMAINING ON PROPERTY O7 POWER FAILURE RELAY SEE ELECTRICAL DRAWINGS LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, O GYP. BOARD CEILING. OR SMUDGES OF ANY NATURE. O 200 AMP PANEL SEE ELECTRICAL DRAWINGS O COORDINATE LOCATION OF THE FOLLOWING W/ FINAL AT&T EQUIPMENT FLOOR PLANS. 9 ENVIRONMENTAL CONTROL PANEL SEE MECHANICAL DRAWINGS O — LIGHT FIXTURES EXTERNAL ALARM PANEL SEE ELECTRICAL DRAWINGS WALL TYPES 10 FLOOR MOUNTED AIR CONDITIONING UNIT REFER TO MECHANICAL DRAWINGS — SPRINKLER HEADS it WAVEGUIDE ENTRY PLATE MICROFLECT CUSTOM 12 PORT THROUGH WALL EXISTING WALLS — DUPLEX OUTLETS 12 SEE ARCHITECTURAL DETAILS 1,2,/A-7. ROUTE COAX VERTICALLY AS PER DTL 7/A7. MANUAL TRANSFER SWITCH. SEE ELECTRICAL DRAWINGS. NEW METAL STUD GYPSUM BOARD WALLS — THERMOSTAT 13 INSTALL VINYL COMPOSITE FLOOR TILE AS PER FINISH SCHEDULE AND MANUFACTURER'S INSTRUCTIONS. O PROVIDE KEYLESS PORCELAIN FIXTURE W/ 24V DC LAMP FOR EMERGENCY LIGHTING 14 (TYP. OF 6). CONNECT TO 24V DC RECTIFIER / CIRCUIT BREAKER AND PROVIDE 15 PROVIDE 4" RUBBER COVE BASE AS PER FINISH SCHEDULE INSTALL ON ALL NEW SWITCH BY DOOR SO THAT LIGHTING FIXTURE IS NORMALLY SWITCHED ON BY AND EXISTING WALLS OF AT&T LEASE AREA. TECHNICAN DURING POWER OUTAGE ONLY. < 16 > INSTALL NEW CONDENSER UNITS ON ROOF (NOT SHOWN). REFER TO MECHANICAL O 2' x 4' FLUOR. LAY—IN FIXTURE Architects — Engineers, P.0 AND ARCHITECTURAL DRAWINGS 12250 East Iliff Avenue, Suite 302 O Aurora, Colorado 80014-1253 17 PORTABLE FIRE EXTINGUISHER PROVIDE ONE (1) 20 LB CO2 UNIT AND WALL BRACKET 7 SMOKE DETECTOR. 303 750 6999 FAX 303 750 0236 Email. kdcdenver®kdcarchitects corn 18 PROVIDE & INSTALL 3-5/8" METAL STUDS W/ 5/8" GYP. BD. EACH SIDE REFER TO 8/A-7. Website• www kdcarchitects corn 19 WINDOW BLINDS TO MATCH SUITE 'B'. 20 PROVIDE AND INSTALL EXHAUST FAN REFER TO MECHANICAL DRAWINGS AT&T WIRELESS SERVICES 21 CONSTRUCT METAL STUD DRYVIT VERTICAL CHASE FROM WAVEGUIDE PORT TO ROOF. REFLECTED CEILING LEGEND • • • : •2101020 003 REFER TO DETAIL 6/A6 TAPE & BED TO MATCH ADJACENT SURFACE 22 2068 SC WOOD DOOR & JAMB W/ LEVER HANDLE HARDWARE 2' X 4' LIGHT FIXTURE (NEW) '�- 23 PROVIDE AND INSTALL A CONTINUOUS 2x8 AROUND PERIMETER OF ROOM FOR CABLE TRAY REFER TO DETAIL SEE 5/A-7 0 KEYLESS 24V DC SURFACE MOUNT FIXTURE 24 TELCO ENTRANCE BOX BY OTHERS MKS ® SMOKE DETECTOR NO DATE ISSUE 25 PROVIDE & INSTALL 3-5/8" METAL STUDS W/ 5/8" GYP. BD EACH SIDE REFER TO 9/A-7 EXHAUST FAN 1 0303.00 CLIENT REVIEW/ZONING 2 0421 00 ZONING 3 0531 00 ZONING REVISION 4 06 1900 ZONING REVISION 5 06 23 00 RF REVISION 20 2 6 06 27 00 ZONING REVISION 07.11 00 OWNER REVISION 6 5 8 10 19 00 CONSTRUCTION/REVISION PUG 12 O 47DC 3 8 (TYP.) (1YP.) 9 11 07 00 CONSTRUCTION/REVISION Fi Q8 A-7 F CO fflo Tr_ �O oo oo O =^ Nm O 8 O KEN 2 � Mloo ❑ 7 N m 39 All 11 I 1 I rr/9�o a V 6 8 ANEL/ o ❑ �� H 2 3 1� y UR AR _ Q All drawings and written material contained MAN o ( herein may not be duplicated used or disclosed TRANS without the written consent of the architect CT CAB SW 13 Cn DISC METER & SW ,� `� 7 ® • SERVICE 18 Elf 14 � 2 3 ENTRANCE N 15 04 ? DISC WEST VAI L SW 6 8 I PANEL/ w ¢ N I 2077 N. FRONTAGE RD. SUR AR 3 = 23 VAIL, COLORADO 81657 F— ,y g /C Ld ANEL M 1 RELAY 1 U 4 10 EXT N o ALARM - �� 11 - - - ROOF-TOP ANTENNAS & <>, =� EQUIPMENT ROOM - - - - T � SHEET TITLE 5 TELCO 18 15 I I 1 25 BD CONSTRUCTION, FINISH, "o AND CEILING PLANS oo . . 17 19 INSTALLATION PLAN (:2 ) FINISH PLAN 3 REFLECTED CEILING PLAN 1 SCALE. 1/4 — 1'-0" SCALE: 1/4" = 1'-0" SCALE- 1/4" = 1'—O" 0 4' 8' 12' 0 4' 8' 12' A 4 0 4' 8' 12' SCALE FEET SCALE FEET SCALE FEET 111111IM __0 24445-7DE-2056—AO4-9 AT&T AT&T Wireless Services SUITE C-1 1001 16TH STREET DENVER, COLORADO 80265-0003 o A / \ -0A K C F� / l�F o \ / / / Architects — Engineers, P.0 / \ 12250 East Iliff Avenue, Suite 302 / Aurora, Colorado 80014-1253 \ / 303 750 6999 FAX 303 750 0236 Email kdcdenver @kdcarchitects.com Website• www kdcarchitects com 9'ROPOSED (2) AT&T PANEL ANTENNAS, 50' SECTOR SEE DETAIL 2,6/A-7. AT&T WIRELESS SERVICES ROOF \ / \ . . Q �` \ 2101020 003 O \ \ p - 1 RPM= : MKS PROPOSED 4'-0 HIGH NO DATE ISSUE / WOOD MECHANICAL SCREEN 01 \ SEE STRUCTURAL DWGS 1 03.03.00 CLIENT REVIEW/ZONING \ / 2 04.21.00 ZONING /PROPOSED COAX ROUTE ON WALL o•. '>- / / 3 05.31 00 ZONING REVISION PROPOSED HVAC ° " / CONDENSERS ON ROOF � 4 06.19.00 ZONING REVISION 5 06 23 00 RF REVISION �- 6 06 27 00 ZONING REVISION PROPOSED (2) AT&T OMNI ANTENNA 07.11.00 OWNER REVISION 10 19 00 CONSTRUCTION/REVISION \ / 11 07 00 STRUCTION/REVISION \ \ OF C 0 WALL MOUNTED CABLE SUPPORT WITH SHROUD. SEE DETAIL 7/A-7. KT-I �° o. ' / �o / AMP � \01, 8 \ / ��� B-1139 D AR \COP 3r- o-. ,. o ,o >, 1 N / �`1 / m All drawings and written material contained �l / herein may not be duplicated used or disclosed 010 F O ROOF d,, O ( / without the written consent o the architect . UPPER L�YEL/ jSITE INFORMATION—___ ROOF/ \ / / ANTENNA FRAME EXISTING TRANSFO ER Pti / \ WALL MOUNTED PR POSED ACCESS P EL \ SEE DETAIL 6/A-7. WEST VAI L SEE TRUCTURAL DR A INGS 2077 N. FRONTAGE RD. \ \ PROPOSE (2� AT&T PAN L / PROPOSED AT&T PANEL \ \ ANTE , 230' 6 ATOR ANTENNAS, 140' SECTOR EE D VAIL, COLORADO 81657 / SEE DETAIL 2/A-7 \ PROPOSED AT&T PANEL / ANTENNAS, 140' SECTOR \ LINE OF EXISTING \41 WALL BELOW �l A-7 0x \ \ \ ROOF-TOP ANTENNAS & \ / EQUIPMENT ROOM SHEET TITLE / \ \ DUMPSTER (TYP OF 2) ONEW DUMPSTER ENCLOSURE ROOF PLAN SEE SHT A-8 (:j)—SCALE 1/8" =1'-0" ROOF PLAN A9 SHEET NUMBER A � 5 24445-7DE-2056—A05-9 S Y AT&T AT&T Wireless Services SUITE C-1 1001 16TH STREET DENVER, COLORADO 80265-0003 PROPOSED HVAC CONDENSERS ON ROOF PROPOSED 4'-0" HIGH MECHANICAL SCREEN Q ■ PAINT TO MATCH BLDG PROPOSED (2) AT&T OMNI ANTENNA PROPOSED (2) AT&T PANEL ANTENNAS, T 0 ROOF 230' SECTOR, PAINT TO MATCH EXISTING BUILDING PROPOSED (2) AT&T PANEL ANTENNAS, T 0. NEW WALL 140' SECTOR, PAINT TO MATCH EXISTING BUILDING ■ , EL 134'-8' f PROPOSED (2) AT&T PANEL ANTENNAS, � OF ANTENNAS � 140' SECTOR, PAINT TO MATCH EXISTING BUILDING — — — — — — — — — — — — EL. 132'-6" EXISTING 8" RUSTIC CEDAR SIDING PENTHOUSE LEVEL EL 124'-8" Z \ UPPER LEVEL EXISTING FLUTED CONCRETE---,,,,, EL. 112'—O" Architects — Engineers, P C 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 Email• kdcdenver®kdcarchitects com Website. www.kdcarchitects.com SUITE 'B' ® LOWER LEVEL AT&T WIRELESS SERVICES EL 106—F R PROVIDE WINDOW BLINDS 204033 003 TO MATCH SUITE 'B' MI . BW MKS 1 SOUTH ELEVATION INO DATE I W SCALE 1/8" — 1'-0" 1 03.0300 CLIENT REV E /Z ONING 2 0421.00 ZONING 3 05.31.00 ZONING REVISION 4 06 1900 ZONING REVISION 5 06 23 00 RF REVISION 6 0627.00 ZONING REVISION 0711 00 OWNER REVISION 8 10 1900 CONSTRUCTION/REVISION 1102.00 CONSTRUCTION/REVISION C%'p PROPOSED 4'-0" HIGH ' MECHANICAL SCREEN PROPOSED (2) AT&T OMNI ANTENNA PROPOSED (2) AT&T OMNI ANTENNA PROPOSED 4'-0" HIGH CAMP PAINT TO MATCH BLDG MECHANICAL SCREEN Q8 PAINT TO MATCH BLDG B-1139 f PROPOSED HVAC PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED HVAC �� 111 7/6,0 230' CONDENSERS ON ROOF SECTOR, PAINT TO MATCH EXISTING BUILDING 50' SECTOR, PAINT TO MATCH EXISTING BUILDING CONDENSER ON ROOF �,S' m All drawings an erial contained herein may not be duplicated used or disclosed i Q8 without the written consent of the architect PROPOSED (2) AT&T PANEL ANTENNAS, PROPOSED (2) AT&T PANEL ANTENNAS, 140' SECTOR, PAINT TO MATCH EXISTING BUILDING 140' SECTOR, PAINT TO MATCH EXISTING BUILDING ® �M AT 10 N EXISTING 8" RUSTIC WEST VAI L CEDAR SIDING 2 VAiL, COLORADO 81657 077 N. FRONTAGE RD. El ROOF-TOP ANTENNAS & EXISTING FLUTED CONCRETE EQUIPMENT ROOM EXISTING 8" RUSTIC CEDAR SIDING —LL M IBM SHEET TITLE ELEVATIONS EXISTING FLUTED CONCRETE SHEET NUMBER WEST ELEVATION EAST ELEVATION 2 SCALE 1/8" = 1'-0" 3 SCALE: 1/8" = 1'-0" A � 6 24445-7DE-2056—AO6-9 1 PROVIDE AND INSTALL MICROFLECT DUPLEX 850+1900 18" CABLE LADDER �-- 01334-12 WAVEGUIDE AT WALL PENETRATION SET IN BED ALPHA OF SEALANT (MICROFLECT RXO/TX1 850 xmit B1177 OR B195) 1 HR RATED EXISTING WALL RXO/TX1 P 1900 xmit RXO/TX 1 RX 1/TX4P 1900 xmit (if needed) RX1/TX6 RX1/TX4 850 xmit — RXO/TX1 P BETA PIPE OR CONDUIT EXISTING ROOF OR WALL AT&T W RX1/TX6P RXO/TX2 850 xmit SUITE CirMess Services ALPHA RXO/TXP2P 1900 xmit PIPE SLEEVE 1001 16TH STREET GAMMA RX1/TX5P 1900 xmit (if needed) DENVER, COLORADO 80265-0003 RXO/TX3P RX1/TX4P RX1/TX5 850 xmit AT&T RX 1/TX4 GAMMA D - 28 1/2° RXO/TX3 RXO/TX3 850 xmit RXO/TX3P 1900 xmit RX1/TX5 RX1/TX5P RXO/TX2P RXO/TX2 RX1/TX6P 1900 xmit (if needed) FILL SPACE Lj RX1/TX6 850 xmit WITH 3M CAULK 1/2' GROUT ALL VOIDS 0 AROUND SLEEVE 0 0 0 o INSTALL A 4" WAVEGUIDE BOOT BETA #6P25—WB PLUS ' (TYP.) ASSEMBLY AT OPENINGS USED INSTALLER INSIDE VIEW FOR COMMUNICATION CABLES OR A SEALING CAP AT SPARE OPENINGS RXO/TX1 RXQ/TX1P RX1 TX4P RX1/TX4 o o CORNER SUPPORT ® ® ■ 0 AS SHOWN N PROVIDE B1118 WAVEGUIDE N ENTRY PLATE BY MICROFLECT RXO/TX2 RXO/TX2P RX1 TX5P(!X1/TX5 N OTE. o o o o o (SET IN BED OF MASTIC SEALANT PIPE ANCHORAGE IS REQUIRED NEARBY TO PREVENT DIRECTLY TO BUILDING SKIN) PIPE MOVEMENT THRU PENETRATION CABLES WITHIN NOTE: SCHEMATIC SAMPLE LADDER SYSTEM CAULK ENTIRE PERIMETER WITH RXO/TX3 RXD/TX3P RX1 CONDUIT PENETRATION SHALL BE APPROPRIATELY 1 HR RATED SEALANT. SEALED AFTER INSTALLATION 0 0 0 0 0 0 COAX ENTRY BOOT AT EXTERIOR WALL COAX COLOR CODE PIPING/CONDUIT WALL PENETRATION COAX SUPPORT LADDER T-CONNECTION K C 1 2 3 4 Architects — Engineers, PC SCALE N T S SCALE NTS SCALE N T S SCALE NTS 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750 6999 FAX 303.750 0236 Email kdcdenver @kdcarchitects corn 2 ALUMINUM SHROUD Website. www.kdcarchitects corn 1 2 X 8 BAND CONTINUED a � RUNWAY END t 3 TYP NEW LAY—IN CLG AT&T WIRELESS SERVICES SUPPORT (SB-163) �— 3/8"Ox6" LAG BOLT T O WALL L_� PROJECT i o 8'-0 204033 003 � U eINV LD ' EXISTING EXTERIOR WALL W/ DP N 1'_ 1 —6 NEW WINDOW BLINDS MICROFLECT #1592____/ X o WALL MOUNT Ld MKS EXISTING FRAME WALL } Ti SB-165 4 3 5/8" 16 GA TOP RAIL • AT&T PANEL > � 1 03 03 00 CLIENT REVIEW ZONING ANTENNA VERIFY ALL VOIDS IN NEW WALL ARE SEALED 2 0421 00 ZONING Q "� w NEW LEASE AREA 3 05.31 00 ZONING REVISION 3-2x6 W/1/2" PLYWD, � 4 06 1900 ZONING REVISION SPACERS 6 6 NEW 3-5/8" 16 GA METAL STUD 5 06.23.00 RF REVISION m zi KEY NOTES: @ 16" 0 C W/ 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE 6 062700 ZONING REVISION O1 UNISTRUT 3/8 DIA P1008 SPRING—LOADED NUT (TYP PER HANGER) TAPE, TEXTURE AND PAINT 07 11 00 OWNER REVISION 10.19.00 CONSTRUCTION REVISION 3/8"Ox6" LAG BOLT O UNISTRUT P1000x18" LONG — ATTACH TO WALL WITH ANCHORS AS TO MATCH ADJACENT WALLS 8 11 02 00 CONSTRUCTION REVISION AUXILIARY STRINGER TUBE REQUIRED FOR WALL CONDITION OR CABLE RUNWAY SB-155 EXISTING WOOD 3 COAX SIZE & QUANTITY AS REQUIRED W NON—INSULATING HANGERS @ PROVIDE AND INSTALL FOIL FACE ( ) / FIBERGLASS INSULATION (R-11) � OC�•Q SIDING 4'-0" OC TYP P '9� ( ) ENTIRE WALL CAVITY 1/2" GPS COAX W/ NON—INSULATED HANGER @ 48" 0 (TYPICAL) F (1ST FLOOR) E O ELEC CONDUIT OR TELEPHONE 0'-0 AMP ® � 0 6 EXISTING WALL SURFACE B-1139 0l7/00 COAX SUPPORT SED A?, LADDER WALL CONNECTION WALL MOUNTED ANTENNA DETAIL WALL MOUNTED CABLE SUPPORT W/ SHROUD s NEW WALL SECTION m All drawings and wn en material contained 5 6 7 herein may not be duplicated used or disclosed without the written consent of the architect SCALE N T S SCALE N T S SCALE N T S SCALE N T S O ' O T 0 EXISTING STEEL DECK WEST VAI L 11'-6 3/4" 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 3 5/8" 16 GA TOP RAIL VERIFY ALL VOIDS IN NEW WALL ARE SEALED ROOF—TOP ANTENNAS & @' 16" O 3-5/8" 8 W/65/8" MYPEL STUD EQUIPMENT ROOM NEW LEASE AREA 'X' GYPSUM BOARD EACH SIDE TAPE, TEXTURE AND PAINT TO MATCH ADJACENT WALLS � SHEET TITLE PROVIDE AND INSTALL FOIL FACE FIBERGLASS INSULATION (R-11) ENTIRE WALL CAVITY F.F. (1ST FLOOR) 0'-0" ARCHITECTURAL DETAILS NUMBER ISHEET 9 NEW WALL SECTION-1 HR. 10 NOT USED 11 NOT USED 12 NOT USED A � 7 SCALE N T S SCALE N T S SCALE N T S SCALE N T S 24445-7DE-2056—A07-9 / / \ AT&T AT&T Wireless Services \ \ SUITE C-1 / \ EXISTING TRANSFORMER // \ / 1001 16TH. STREET / DENVER, COLORADO 80265-0003 < \\ \\ EXISTING RETAINING WALL \\ i / / \\ \\ EXISTING TRANSFORMER \\ \\\ / / / 1 \ / \ \\ / EXISTING BUILDING \ \ /< \ \ \ \ KDC Architects — Engineers, P C 2-5-0" GATES \ / // 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750 6999 FAX 303.750.0236 \ / `'� \ \ // \ Email kdcdenver®kdcarchitects com Website www.kdcarchitects com \\ AT&T WIRELESS SERVICES PROJECT 2101020 003 on DP \ / MKS \ \ NO DATE ISSUE 1 03 03 00 CLIENT REVIEW/ZONING \ \ \ 2 04.2100 ZONING 3 0531 00 ZONING REVISION \ \ \ 4 06 1900 ZONING REVISION \ \ / 5 06 23 00 RF REVISION 6 06 27 00 ZONING REVISION 071100 OWNER REVISION ` 8 10 19 00 CONSTRUCTION/REVISION 11.07.00 CONSTRUCTION/REVISION \ 4"0 STL BOLLARD TYP OF 4 COC '9 COD\ / N TEb CAMP \ B-1139 '' ® All drawings an wri ten material contained ,�, \ herein may not be duplicated used or disclosed without the written consent of the architect. 2-5-0" GATES WEST VAIL \ \ \\ 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 \ \ \ \ \ \ \ \\ ROOF-TOP ANTENNAS & \ \ \ EQUIPMENT ROOM SHEET TITLE \ \ \ \ \ DUMPSTER CORRAL SITE PLAN PARTIAL SITE PLAN ISHEETNUMBER 1 SCALE 1/4" = 1'-0" A 8 24445-7DE-2056—AO8-9 EXISTING TRANSFORMER AT&T Wireless Services \ / \ 2 x 12 RAKE AND EAVE TRIM SUITE 6TH. STREET \ / / 12 12 DENVER, COLORADO 80265-0003 / 3 2 x 12 RAKE AND EAVE TRIM 3 AT&T \ EXISTING BUILDING / \ T 0. BEAM T.0 BEAM ' \ \ 2 � / 10'-0" 10,-0" A-9 5 / 5 IN / \ 2-5'-0" GATES GATES W HEAVY DUTY COMMERCIAL / o HINGES AND LATCHES T.0 SLAB T 0 SLAB 01-O" K C Architects — Engineers, P.0 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 / 303 750 6999 FAX 303 750 0236 / \ Email kdcdenver®kdcarchitects com Website• www kdcorchitects com SHED BACK ELEVATION SHED FRONT ELEVATION AT&T WIRELESS SERVICES SCALE- 1/4" = 1'-0" SCALE. 1/4" = 1'-0" "PROJECT : 2101020.003 COMP SHINGLE ROOF DP \ \ \ ,9, 2 x 10 RAKE AND EAVE TRIM MKS • DATE ISSUE Z7' 1 03 03 00 CLIENT REVIEW/ZONING T 0 BEAM 2 0421 00 ZONING 3 0531.00 ZONING REVISION \ 0 lot-010 4 06 19.00 ZONING REVISION 5 0623.00 RF REVISION \ \ \ 6 06.27.00 ZONING REVISION 07 11 00/ \ 8 OWNER 110 1900 CONSTRUCTION/REVISION r 4"0 STL BOLLARD / \ 9 11.0700 CONSTRUCTION REVISION TYP OF 4 \ a \ \ T0 SLAB B-1 139 01 01-011 � li''7i!oc> �o \ \ \ 5x5 TS COL Al 0-110c> TYP m All drawings` ' written material contained i \ herein may not be duplicated used or disclosed without the written consent of the architect LP. 4 Q \ • - A-9 4 SHED SIDE ELEVATION WEST VAI L \ SCALE 1/4" = 1'-0" \ \ 2 x 12 RAKE AND EAVE TRIM 2077 N. FRONTAGE RD. \ VAIL, COLORADO 81657 2-5-0" GATES T 0 BEAM 101—C 09*060 A-9 \ \ ROOF—TOP ANTENNAS & V GATES W/HEAVY EQUIPMENT ROOM DUTY COMMERCIAL HINGES AND LATCHES SHEET TITLE 01-0to LAB DUMPSTER CORRAL FLOOR PLAN & ELEVATIONS 1 FLOOR PLAN iSHEET NUMBER SCALE. 1/2" = 1'-0" SHED SIDE ELEVATION 5 SCALE 1/4" = 1'-0" 24445-7DE-2056—AO9-9 AT&T AT&T Wireless Services SUITE C-1 1001 16TH STREET DENVER, COLORADO 80265-0003 - - - - - - - -- - - - - - - - - - - - -i I _ I I 0 I COMP SHINGLE ROOF ON (2) LAYERS #15 FELT ON 5/8" CDX PLYWOOD W/GALV. METAL I _ W DRIP EDGE 8X10 BEAM I ° 1 0 I 'n i I I o I I 2 x 12 @ 16"0 C. 1 1/ 5x5 TS COLUMN NOT USED K C 3 5x5 TS TOP RAIL 1 5'-0" 1 Architects — Engineers, PC I _ _ I SCALE 3/4" = 1' 12250 East Iliff Avenue, Suite 302 W 8X10 BEAM I / � / � I Aurora, Colorado 80014-1253 1 0 303 750 6999 FAX 303 750 0236 1x8 WOOD SIDING i �\ _ �\_�� 6'-6" Email- kdcdenver®kdcarchitects.com 1x8 WOOD SIDING e site• www k carc i ec s com 1 6" CONCRETE — I I SLAB - 6" STL 'C' 6" 'C' MID SUPPORT -i I AT&T WIRELESS SERVICES MID SUPPORT cD I I PROJECT 18"0 MINIMUM ° 1 1 2101020.003 00 I I I METAL POST BASE 1 1 DP AND CAP I 5x5 TS BOTTOM RAIL I 4" STL BOLLARD TYP OF 4 MKS °0 T 0 SLAB L - - - - - - - - - -- - - - - - - - - -� 0'-0" 18" x 18" x 18" DP 1 03.03.00 CLIENT REVIEW/ZONING 2 04.21.00 ZONING 4"0 STL BOLLARD 3 05.31.00 ZONING REVISION SEE 5/A10 4 06.19.00 ZONING REVISION 5 06 23 00 RF REVISION 0 6 0627.00 ZONING REVISION 0711 00 OWNER REVISION CD 8 10 1900 CONSTRUCTION/REVISION 9 11 07 TRUCTION/REVISION 0"i oto �P �O KE E 8-1139 All U/71000 SHED SECTION 2 FOUNDATION/BOLLARD LAYOUT PLAN 4 NOT USED m All drawings and written material contained 1 herein may not be duplicated used or disclosed without the written consent of the architect. SCALE 1/2" = 1'-0" SCALE 3/8" = 1' SCALE N T S WEST VAIL CONCRETE CAP 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 4"0 SCHEDULE 40 CARBON STEEL PIPE FILLED WITH CONCRETE AND PAINTED _ YELLOW IN ACCORDANCE cD WITH THE DESIGN AND CONSTRUCTION SPECIFICATIONS FOR PAINTING ROOF—TOP ANTENNAS & EQUIPMENT ROOM > a bc a D ° , ° 4 ° Q 6" CONCRETE � SHEET TITLE SLAB A cZc G n d N z DUMPSTER CORRAL CONCRETE FOUNDATION PLAN, z BLDG. SECTION & DTLS. ° 18" MIN SHEET NUMBER� < > - z 5 BOLLARD DETAIL 6 NOT USED 7 NOT USED 8 NOT USED A10 SCALE N T S SCALE N T S SCALE N T S SCALE N T S 24445-7DE-2056—A10-9 3/S-2 711/S-2 4'-0" }�2'-6"_ 4'-0" 4'-0" 4'-0" 4'-0" 4'-0" C8X11 5 C8X11 5 LJ PROPOSED HVAC N \11' X CONDENSERS ON ROOF !yj I � ( co X X ��9 � rM CBX11 5 W6X15 I II - - - - - - - W6X15 5'-3" 5'-3" ' AT&T Wireless Services I) I) \N,g q _ 4 _ SUIT 16TH STREET o 0 2/5-2 5/S 2 W6X15 /S 2 W6X15 1/4 F R P. SCREEN PAINT TO MATCH , DENVER, COLORADO 80265-0003 O 1/4" F R P SCREEN PAINT TO MATCH 4 SEN EMMORM 0131M Elm I I I I co o 5 SECTION S =1'-0' ROOF Cx S � SCALE• 1/8"=1'-0' '�`* UPPER LEV L - - - OOF 4'-0" 2'-0" 4'-0" 2'-0" 4'-0" N W6 15 ��. 9 4'-0" 4'-0' C8X 1.5 �n I °� I � Z410 ,. W6X15 I 9 I 1. C8X11 5 4 ' 6/S-2 W6X15 W6X15 W6X15 - - - - - - - - - - - 4 X X 4 W6X15 W6X15 co REMOVABLE ACCES PANEL 5 SECTION 1/4" F R P SCREEN PAINT TO MATCH SCALE 1/811=1'-0' SECTION KDC SCALE: Architects - Engineers, P C. I I 12250 East Iliff Avenue, Suite 302 4'-0" 4'-0° r�� Aurora, Colorado 80014-1253 SEALANT 303.750.6999 FAX 303 750,0236 COUNTER FLASHING Email kdcdenver @kdcarchitects com 4'-0" 8'-0" 4'-0" 2"x6" PRESSURE Website- www kdcarchitects com TREATED AT&7 NOTE: LOCATION OF BEAMS ON THE ROOF TO MATCH LOCATION INSULATION BASE FLASHING OF STUDS IN THE WALL W6X15 BEAMS SHALL BE FASTEN ROOF MEMBRANE AT&T WIRELESS SERVICES TO ROOF DECK W/ 1/2" DIA. LAG BOLTS AT 2'-Q" O.C. THE BOLTS SHALL BE STAGGERED ON BOTH SIDES OF P • THE WEB 2101020.003 EXIST'G DECK DRAWN SCREEN SUPPORT FRAMING PLAN x' 2 SCALE 1/8"=1'-0' CHECKED BY MKS • DA PENHOUSE ROOF FRAMING PLAN FLASHING DETAIL SCALE. 1/8"=1'-0' 7 SCALE 1"=1'-0' 1 03.0300 CLIENT REVIEW/ZONING 2 0421.00 ZONING 3 05.3100 ZONING REVISION 4 06.19.00 ZONING REVISION 5 06 23 00 RF REVISION 6 06.27.00 ZONING REVISION �t 7 07.1100 OWNER REVISION 8 10 1900 CONSTRUCTION/REVISION ' 9 11 0700 CONSTRUCTION/REVISION 4 0 All drawings and written material contained herein may not be duplicated used or disclosed GENERAL NOTES STRUCTURAL STEEL GENERAL NOTES 11 . ALL CONNECTIONS FOR WHICH REACTIONS ARE NOT VISIT TO SIGHT GENERAL NOTES without the written consent o1` the architect. SHOWN ON THE PLANS SHALL DEVELOP THE END 1 . ALL PARTIES INVOLVED IN CONSTRUCTION ON THIS 1 . ALL STRUCTURAL STEEL WORK SHALL CONFORM TO REACTIONS FROM THE TABLES OF UNIFORM LOAD 1 .PROJECT SHALL BE FAMILIAR WITH GUIDELINES PRESENTED IN THE CURRENT ISSUE OF THE AISC SPECIFICATIONS FOR CONSTANTS, VI ALL EXISTING CONDITIONS SHALL BE NOTED BY A SIGHT THESE NOTES AND CONFORM TO THEIR REQUIREMENTS. PART 2 OF THE AISC MANUAL. IN NO CASE VISIT BEFORE SUBMITTING A BID. SHOP DRAWINGS ® � g THE DESIGN, FABRICATION, AND ERECTION OF HOWEVER, SHALL CONNECTIONS HAVE LESS BOLTS THAN 2. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS STRUCTURAL STEEL FOR BUILDINGS, AND SHALL COMPLY THE FOLLOWING: ' GENERAL NOTES OF EXISTING CONSTRUCTION BEFORE PROCEEDING WITH HIS WITH ALL LOCAL LAWS AND ORDINANCES. W8-W10 : 2 ROWS W21 -W24 : 5 ROWS ''` WEST VAI L WORK. 2. STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 3. CONTRACTOR SHALL PERFORM HIS WORK IN STRICT W12-W14 3 ROWS W27-W30 6 ROWS 1 . SUBMIT ONE REPRODUCIBLE COPY AND TWO PRINTS OF W16-W18 : 4 ROWS W33-W36 : 7 ROWS ACCORDANCE WITH CURRENT BUILDING CODES. (FY=36 KSI). SHOP DRAWINGS TO ARCHITECT FOR REVIEW. , 3. STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM 12. ALL CONNECTIONS OF FLOOR MEMBERS SHALL HAVE 2. PRIOR TO SUBMISSION THE DRAWINGS SHALL BE 2077 N. FRONTAGE RD. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY BRACING, THE MINIMUM NUMBER OF BOLTS AS FOLLOWS: SHORING OR NEEDLING REQUIRED DURING CONSTRUCTION TO A500 GRADE B ROUND (FY=42 KSI) SQUARE OR REVIEWED BY DETAILER. VAIL, COLORADO 81657 RECTANGULAR (FY=46 KSI) W18 : 5 ROWS W30 : 8 ROWS ASSURE SAFE WORKING CONDITIONS ON THE JOB. W21 : 6 ROWS W33 : 9 ROWS 3. DETAILS MUST BE ON SHEETS AT LEAST 24"X36". 5. WIND LOAD 4. STEEL PIPE SHALL CONFORM TO ASTM A53 TYPE E 4. REPRODUCTIONS OF STRUCTURAL DESIGN DRAWINGS OR S, GRADE B (FY=35 KSI) W24-W27 7 ROWS W36 10 ROWS BASIC WIND SPEED 80 MPH. 13. ALL BEARING ENDS OF ALL COLUMNS SHALL BE SHALL NOT BE USED AS ERECTION DRAWINGS. EXPOSURE B 5. BOLTS SHALL BE 3/4 DIAMETER, UNLESS NOTED. 5. COLUMN AND LINTELS DESIGNATIONS SHALL FALLOW THE HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325 MILLED OR FINISHED. 6. SEISMIC ZONE 1 14. THE CONTRACTOR SHALL SUPPLY ALL TEMPORARY NUMBERING SYSTEM USED ON THE DESIGN DRAWINGS. 6. 7. SNOW LOAD 100 PSF. ANCHOR BOLTS SHALL CONFORM TO ASTM A36. ALL OTHER CONTRACTOR SHALL WORK WITH THE LATEST COPIES OF THE BOLTS SHALL CONFORM TO ASTM A307 BOLT HOLES BRACING REQUIRED TO MAINTAIN PLUMBNESS AND DESIGN DRAWINGS AND THE SHOP DRAWINGS FOR ALL SHALL CONFORM TO AISC REQUIREMENTS. STABILITY DURING ERECTION. BRACING SHALL NOT BE TRADES INVOLVE. 6. ALL WELDING SHALL CONFORM TO THE CURRENT REMOVED UNTIL ALL PERMANENT BRACING HAS BEEN SPECIFICATIONS OF THE AMERICAN WELDING SOCIETY, INSTALLED, ALL WELDING HAS BEEN COMPLETED, ALL 7. ENGINEER SHALL RECEIVE A SHOP DRAWINGS TEN ROOF-TOP ANTENNAS & AND SHALL COMPLY WITH ALL LOCAL LAWS AND BOLTS HAVE BEEN PROPERLY TIGHTENED, AND FLOOR WORKING DAYS PRIOR TO REQUIRED DATE OF APPROVAL BY ORDINANCES. WELDING ELECTRODES SHALL BE E-70 SLAB HAVE BEEN PROPERLY PLACED. CONTRACTOR. MISSED DUE DEADLINES ARE THE EQUIPMENT ROOM SERIES. 15. ALL COLUMN ANCHOR BOLTS WITH NUTS AND CONTRACTORS RESPONSIBILITY. 7. ALL CONNECTIONS SHALL BE FRAMED BEAM WASHERS, AND LEVELING PLATES SHALL BE SUPPLIED STRUCTURAL STEEL TESTING GENERAL NOTES CONNECTIONS CONFORMING TO THE REQUIREMENTS OF BY THE STRUCTURAL STEEL CONTRACTOR, AND SET BY PART 4 OF THE AISC MANUAL. THE FOUNDATION CONTRACTOR. 1 . TESTING LABORATORY SHALL INSPECT STRUCTURAL STEEL ' SHEET TITLE 8. ALL BOLTED CONNECTIONS SHALL BE MADE WITH 15. NO OPENINGS SHALL BE CUT IN STRUCTURAL MEMBERS WORK. HIGH STRENGTH BOLTS, UNLESS NOTED. CONNECTIONS UNLESS SHOWN ON THE DRAWINGS, OR APPROVAL IS 2, LABORATORY SHALL PERFORM THE FOLLOWING: SHALL BE "BEARING TYPE", WITH THREADS INCLUDED IN RECEIVED FROM THE ENGINEER. - COLUMN BASES SHALL BE CHECKED FOR BEARING THE SHEAR PLANE, UNLESS NOTED. 17. STEEL SHALL BE PAINTED WITH COAT OF APEX BASIC - STEEL MEMBERS SHALL BE CHECKED FOR PLUMBNESS 9. ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO LEAD SILICO CHROMATE PRIMER TYPE 2, UNLESS NOTED. SCREEN FRAMING PLAN PROVIDE AT LEAST THE MINIMUM TENSION SHOWN IN 18. ALL LOOSE STEEL LINTELS SHALL BE PROVIDED BY AND ALIGNMENT TABLE 2, FASTENER TENSION, OF THE SPECIFICATION THE STEEL CONTRACTOR. - HIGH STRENGTH BOLTED CONNECTIONS SHALL BE CHECKED BY CALIBRATED WRENCHES FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 19. ALL PERIMETER STEEL BEAMS SHALL BE ANCHORED BOLTS, UNLESS NOTED. TO EXTERIOR WALLS WITH MASONRY ANCHORS TOP AND - STANDARD BOLT CONNECTIONS SHALL BE CHECKED 10. FIELD CONNECTIONS TO EXISTING STEEL SHALL BE BOTTOM AT 4'-0" 0/C MAXIMUM. FOR TIGHTNESS �� 'SHEET NUIVIIIBER'il. :, . WELDED, UNLESS NOTED. 20. ALL COLUMNS WHICH SIDES ARE IN CONTACT WITH - DAMAGE AND DEFORMATION IN ALL STRUCTURAL MASONRY SHALL BE ANCHORED TO MASONRY WALLS WITH MEMBERS SHALL BE RECORDED STRAP ANCHORS AT 2'-8" 0/C MAXIMUM. 3. GENERAL CONTRACTOR AND TESTING LABORATORY SHALL 21 . ALL STEEL MEMBERS WHICH ARE REQUIRED TO BE NOTIFIED BY STEEL CONTRACTOR WHEN STEEL WORK IS SUPPORT OTHER MATERIALS SHALL BE EQUIPPED WITH READY FOR TESTING. a, HOLES AND ANCHORS. 4. THE OWNER SHALL RECEIVE THREE COPIES OF THE REPORT. 24445-7DE-2056- S01-9 �y. ri AT&T 3/16 AT&T Wireless Services SUITE C-1 — — — — — 1001 16TH STREET — — — — — — — i C8X11 5 DENVER, COLORADO 80265-0003 - - -C8X11 5 — - - i 3/16 '• " 1/2 STL PLATE ' x I 3/8" STL. PL. L 4x4x5/16 I � 4- L '9 kK L 4x4x5/16 I I C8X11.5 xl W6X15 3/16 j 3/16 D �SC!�T E T1'-0" � 1/2"=1'-0" 3 SCALE. 1 KDC Architects — Engineers, P C 12250 East Iliff Avenue, Suite 302 st Aurora, Colorado 80014-1253 303.750 6999 FAX 303.750 0236 Email- kdcdenver @kdcarchitects com CD Website. www kdcarchitects com 3/16 I 3/16 1/2- STL. PLATE 3/8" STL. PL. AT&T WIRELESS SERVICES C8X11 5 PROJECT—NUMBER _ 2101020 003 C8X 11.5 ro N-1 mm W6X15 W6X15 W6X15t CHECKED BY MKS W6X15 W6X15 �` r 1 03 03 00 CLIENT REVIEW/ZONING 2 0421.00 ZONING ,. 3 0531 00 ZONING REVISION 4 061900 ZONING REVISION DETAIL DETAIL DETAIL 5 0623.00 RF REVISION 6 06 27 00 ZONING REVISION SCALE 1 1/2"=1'-0" SCALE. 1 1/2"=1'-0" " SCALE. 1 1/2"=1'-0" 7 071100 OWNER REVISION 8 10 19 00 CONSTRUCTION/REVISION 9 11 0700 CONSTRUCTION/REVISION 0 51 a N' 01 I n m All drawings and written material contained herein may not be duplicated used or disclosed without the written consent of the architect. s WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 ki ROOF-TOP ANTENNAS & EQUIPMENT ROOM � SHEET TITLE SCREEN SECTIONS AND DETAILS SHEETNUMBER a 24445-7DE-2056— S02-9 FOUNDATION GENERAL NOTES 1. FOUNDATIONS ARE DESIGNED FOR 2000 PSF ALLOWABLE BEARING PRESSURE, AT&T 2. CONCRETE FOR FOUNDATIONS AND SLABS SHALL #4 © 12" o.c Ew. DEVELOP A MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS, 3. REINFORCING BARS SHALL CONFORM TO ASTM A615 AT&T Wireless Services SUITE C-1 2 GRADE 60 AND ACI CODE REQUIREMENTS. 1001 16TH STREET S_3 a 4, ALL CONCRETE SHALL BE PLACED IN ACCORDANCE DENVER, COLORADO 80265-0003 Q � WITH ACI 304 SPECIFICATION, 04 72 4 2 — #5 CONCRETE GENERAL N❑TES r- —— — — — — — — — —— — — — —— —— — - #5 1, ALL CONCRETE WORK SHALL CONFORM T❑ THE I BUILDING CODE REQUIREMENTS FOR REINFORCED ,' I r O I CONCRETE (ACI 318-95), AND SHALL COMPLY WITH ALL I I :#4 TIES @ 18" 0 C LOCAL LAWS AND ORDINANCES, 2, ALL CONCRETE SHALL BE NORMAL WEIGHT, UNLESS NOTED, HAVING A MINIMUM COMPRESSIVE STRENGTH OF F'C=3,000 PSI AT 28 DAYS, I I b 3. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 (FY=60 KSI) " i I 4. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS FOLLOWS: j 0�� j CAST AGAINST AND PERMANENTLY EXPOSED TO I I EARTH....,,,..3" TYP. SECTION EXPOSED TO EARTH OR WEATHER (WHERE FORMES ARE KDC 2 USED) SCALE �" - �' #6 BARS AND LARGER.................................2" Architects — Engineers, PC I i N i I #5 BARS AND SMALLER..............................1-1/2" 12250 East Iliff Avenue, suite 302 •� Aurora, Colorado 80014-1253 1 t 0 l IR 303.750 6999 FAX 303.750.0236 NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND Email kdcdenver @kdcorchitectscom SLABS AND WALLS..............................................3/4' website` www kdcarchitects com 6" CONCRETE I i BEAMS, GIRDERS, COLUMNS..........................1/2" SLAB .q 5. ALL SLEEVES, SLOTS AND OTHER EMBEDDED AND AT&T WIRELESS SERVICES I I UNDER SLAB ITEMS SHALL BE SET BEFORE CONCRETE IS :PROJECT NU ; - I I 18"0 MINIMUM I I PLACED SEE ARCHITECTURAL, MECHANICAL, ELECTRICAL 2101020003 m I I AND VENDOR'S DRAWINGS FOR SIZES AND LOCATI❑NS. _ I 6, FABRICATI❑N, ERECTI❑N AND DETAILING OF 2 I I REINFORCING BARS SHALL CONFORM TO THE DP S-3 I I 4" STL BOLLARD REQUIREMENTS OF "ACI DETAILING MANUAL (ACI 315)" CHECKED I I TYP. OF 4 LATEST EDITION, MKS L- —— — — —— — — — —— — — — —— — —— J 7, ALL CONCRETE SHALL BE PROPERLY VIBRATED, NO ISSUE 8. ALL CONCRETE PLACEMENT SHALL CONFORM TO ACI 18" x 18" x 18" DP 304, LATEST EDITION 1 030300 CLIENT REVIEW/ZONING 2 0421 00 ZONING CONCRETE TESTING GENERAL NOTES 3 05.3100 ZONING REVISION <_ 4 061900 ZONING REVISION 1. A TESTING LABORATORY SHALL BE REQUIRED TO CAST 5 06.2300 RF REVISION AND TEST A SET OF THREE CYLINDERS FOR EVERY 75 6 06.2700 ZONING REVISION 7 07.11 00 OWNER REVISION CU, YARDS OR LESS. 8 10 19 00 CONSTRUCTION/REVISION 2. SLUMP TEST SHALL BE PERFORMED BY QUALIFIED g 1107.00 CONSTRUCTION/REVISION PERSONNEL, CONCRETE NOTES ; 3 NITS SCALE 1 ® AII drawings and written material contained FOUNDATION PLAN herein may not be duplicated used or disclosed without the written consent of the architect. SCALE. 3/8" = 1' Fbe WEST VAIL 2077 N. FRONTAGE RD. ax VAIL, COLORADO 81657 s., •i, ,.w f pf w" W ROOF-TOP ANTENNAS & EQUIPMENT ROOM SHEET; TITLE DUMPSTER CORRAL FOUNDATION PLAN, AND SECTION SHEET NUMBER S � 3 y 24445-7DE-2056— S-3 i} r ty x 'T1Y� f. AT .ri a+ r j: e AT&T Wireless Services SUITE C-1 1001 16TH STREET t. DENVER, COLORADO 80265-0003 CrAmm9m came= rk 12 x. 3 2x12 RAKE & EAVE TRIM WT 4X9 W 8x10 COMP SHINGLE ROOF 5x8x1/2 W 8x10 x x CAP STL PLATE CAP STL P LATE CAP STL PLATE TS 4x4 5/16" TS 4x4 5/16" i r r� TS 445/16 WT 4x9 r W 8x10 r --------ti----------------------------- - ------�------------------------------ - -----�------------------------- 5x8x1/2 AT 4x9 WT 4x9 CAP STL PLATE 5x8x1/2 /2� 2" KDC Sri � CAP STL PLATE ST! Ro STS Architects — Engineers, PC �0 TS 4x4x5/16 WT 4x9 WT 4x9 �� 12250 East Iliff Avenue, Suite 302 WT 4x9 � ------------------ ------------------ - ------------------ ------------------ Aurora Colorado 80014-12 303 750.6999 FAX 303 750 0236 Email kdcdenver @kdcarchitects corn Website: www kdcarchitects.com — 5x8x1/2 1l� WT 49 5x8x1/2 ��� WT 4 �l WT 4x ""-- BASE STL. PLATE BASE STL. PLATE W/ 2-3/4" 0 A325 A.B. W/ 2-3/4" 0 A325 AB. AT&T WIRELESS SERVICES x TS 4x4x5/16 TS 4x4x5/16 rn PROJECT NUMBER 5x8x1/2 5x8x1/2 5x8x1/2 2101020 003 BASE STL. PLATE BASE STL. PLATE BASE STL. PLATE DRAWN W/ 2-3/4" 0 A325 A B W/ 2-3/4" 0 A325 A.B. W/ 2-3/4" 4 A325 A B �CHECKED BY : SHED SIDE ELEVATION ED SIDE ELEVATION (�A3V'c MKS S CALE 3/8" = 1'-0" E• 3/8" = 1'-0" i • DATE oISSUE 1 0303.00 CLIENT REVIEW/ZONING 1 . 2 0421 00 ZONING 3 0531.00 ZONING REVISION 1 1 4 06 1900 ZONING REVISION tam TS 44 5/16" 5 0623.00 RF REVISION PROVIDE HEAVY DUTY HINGE WELDED 6 06.27.00 ZONING REVISION ` OR BOLTED TO COLUMN "' 7 07 11 00 OWNER REVISION {` 8 10 1900 CONSTRUCTION/REVISION ng 1■� °t- 9 11 0700 CONSTRUCTION/REVISION TS 444 5/16 L 3"x3"x1/4" STL FRAME GATE W1 WOOD SIDING rn 3 1 - 1 O W 8x10 1 1 W 8x10 1 5x8x1/2" 5x8x1/2" 1 CAP STL PLATE CAP STL. PLATE ®AII drawings and written material contained 1 1 5x8x1/2 herein may not be duplicated used or disclosed 1 1 CAP STL, PLATE TS 4x4x5/16 without the written consent oi` the architect. 1 TS 4x4x5/16 W 8x10 1 1 WT 4x9 a 1 1 TS 4x4x5/16 - ---------------------------------- --- - 1 CAPx STL PLATE T WEST VAI L GATE GATE � 1 r. x 1 " << 1 1 TS 4x4x5/16 4x9 2077 N. FRONTAGE RD. 1 1 1 VAIL, COLORADO 81657 1 1 i WT 49 5x8x1/2 5x8x1/2 5x8x1/2 y$: 5x8x1/2 5x8x1/2 BASE STL PLATE BASE STL PLATE BASE STL PLATE BASE STL PLATE BASE STL. PLATE ROOF-TOP ANTENNAS & W/ 2-3/4" 4 A325 A B W/ 2-3/4" 0 A325 A B W/ 2-3/4" 0 A325 A B W/ 2-3/4" 0 A325 A B W/ 2-3/4" 0 A325 A.B. EQUIPMENT ROOM 4 SHED SIDE ELEVATION SHED SIDE ELEVATION SHEET TITLE SCALE 3/8 1'-0" SCALE 1/4" 1'-0" FLOOR PLAN & ELEVATIONS v DUMPSTER PLAN 1 SCALE- 112" = 1'-0" � �;' 24445-7DE-2056—S-4 HVAC GENERAL NOTES AIR HANDLER UNIT SCHEDULE LEGEND SYMBOL ABB. DESCRIPTION SYMBOL ABB. DESCRIPTION AREA COOLING SUPPLY ® SAD SUPPLY AIR DUCT PD PD PRESSURE DIFFERENTIAL SWITCH 1 THE HVAC CONTRACTOR SHALL PERFORM THE WORK IN ACCORDANCE WITH SYM MFR & MODEL # SERVICED CAPACITY HP ESP CFM Q 12" FLA FUSE MCA V PH HZ WT REMARKS ® RAD RETURN AIR DUCT s S SWITCH . THE BEST ASHRAE AND INDUSTRIAL STANDARDS. AC TRANE ® OSA OUTSIDE AIR — RL — RL REFRIGERANT LIQUID AT&T 2. ALL HVAC WORK SHALL COMPLY WITH ALL APPLICABLE CODES OF THE e TWE063P13FB SEE PLAN 60,000 BTU 3/4 55 2000 54 15A 15A 208 1 60 120 PROVIDE DISCONNECT ® EAD EXHAUST AIR DUCT — RS — RS REFRIGERANT SUCTION STATE OF COLORADO, LOCAL BUILDING CODES AND FEDERAL CODES, TRANE PROVIDE DISCONNECT - BDD BDD BACKDRAFT DAMPER — CD — CD CONDENSATE DRAIN HAVING JURISDICTION OVER THE CONSTRUCTION. 2� TWE063P13FB SEE PLAN 60,000 BTU 3/4 55 2000 5 4 15A 15A 208 1 60 120 0 (L) LINED DUCTWORK O C 0 C ON CENTER 3 HVAC CONTRACTOR SHALL EXAMINE THE PROJECT SITE AND DISCUSS ® CD CEILING DIFFUSER EXIST EXISTING AT&T Wireless Services GENERAL REQUIREMENTS OF BUILDING AND WORK PERFORMANCE WITH * SMOKE DETECTOR TO SHUT DOWN UNIT UPON DETECTION & SEND SIGNAL TO EXTERNAL ALARM PANEL FOR AC-1 & AC-2 ® RAR RETURN AIR REGISTER 9 POC POINT OF CONNECTION SUITE C-1 OWNERS REPRESENTATIVE CONTRACTOR SHALL COORDINATE HIS WORK * PROVIDE AND INSTALL LOW AMBIENT EQUIPMENT TO PROVIDE -20' OPERATION -- REFERENCE MANUFACTURER'S REP AND NOTE ON M-2 FOR EQUIPMENT REQUIRED 19 EAR EXHAUST AIR REGISTER Th THROAT 1001 16TH STREET WITH THE WORK OF OTHERS ON THE PROJECT CONTRACTOR SHALL D[—G SWR SIDEWALL SUPPLY REGISTER ID INSIDE DIMENSION DENVER, COLORADO 80265-0003 CONFIRM EXISTING CONDITIONS AND PROVIDE ALL LABOR AND O VTR VENT THRU ROOF OD OUTSIDE DIMENSION MATERIALS TO MAKE A WORKABLE AND USABLE SYSTEM. 4 HVAC CONTRACTOR IS TO REPORT TO OWNERS REPRESENTATIVE ANY CONDENSING UNIT � Fc FLEXIBLE CONNECTION w/ WITH +--to AFD AUTOMATIC FIRE DAMPER S/M SHEET METAL OBSERVATIONS OR CONDITIONS WHICH ARE DISCOVERED IN THE +-+ MVD MANUAL VOLUME DAMPER S 5 STAINLESS STEEL ■ BUILDING WHICH WOULD PREVENT THE FULLEST USE OF THE HVAC SYM MFR & MODEL V PH HZ COMP. FAN MFS SEER WT REMARKS 1 0 1 QBD QUADRANT BALANCING DAMPER GC GENERAL CONTRACTOR SYSTEM # DL DOOR LOUVER 4- - - --`y EXIST TO REMAIN 5. HVAC CONTRACTOR SHALL ARRANGE AND PAY FOR ALL FEES, PERMITS, CU TRANE MODEL UU- UC UNDERCUT DOOR 3/4° 5f�f�-/-5 EXIST TO BE DEMOLISHED AND INSPECTIONS CONCERNING HIS WORK 1 TTP 060D100A 208 1 60 30 7A 1 4A 60A 12 328 LOW AMBIANT KIT REFERENCE M-2 r STAT THERMOSTAT ®/ COMBINATION SMOKE FIRE DAMPER 6. HVAC CONTRACTOR SHALL FIELD VERIFY ALL ELECTRICAL POWER CU SAME AS CU-1 PROVIDE FACTORY CURB H H STAT HUMIDISTAT ® SMOKE DETECTOR ■ CHARACTERISTICS PRIOR TO ORDERING ANY MECHANICAL EQUIPMENT 2 BT BT BY-PASS TIMER Ts TS TEMPERATURE SENSOR 7. ALL LOW VOLTAGE WIRING SHALL BE INSTALLED BY THE HVAC * SMOKE DETECTOR TO SHUT DOWN UNIT UPON DETECTION & SEND SIGNAL TO FIRE ALARM PANEL FOR AC-1 & AC-2 ' CONTRACTOR * PROVIDE AND INSTALL LOW AMBIENT EQUIPMENT TO PROVIDE -20' OPERATION -- REFERENCE MANUFACTURER'S REP FOR EQUIP REQUIRED REFER TO SHT M-2 8. THE ROOM THERMOSTATS SHALL BE CAPABLE OF BEING SET FROM 557 TO 85'F 9 A DURABLE MAINTENANCE LABEL MUST BE AFFIXED TO MECHANICAL EXHAUST FAN SCHEDULE EQUIPMENT. TWO COPIES OF A MAINTENANCE MANUAL FOR THE EQUIPMENT ITEMS SHALL BE PROVIDED TO THE OWNER BY THE SYM MFR & MODEL AREA SERVICED CONTRACTOR CFM ESP HP V PH WT FAN RPM TIP SPEED REMARKS 10. CONDENSATE DRAINS FROM AIR HANDLER COIL TO BE DWV COPPER EF COOK BELT DRIVE INSTALL UNIT TUBING. GRAVITY DRAINS AND PRESSURIZED DRAINS SHALL BE e ACE-10OC28 SEE PLAN 440 1/8" 1/6 120 1 15 955 2502 WITH DRIVE INVERTICAL INDIRECT DRAINS SHALL BE SUPPLIED AND INSTALLED BY THE HVAC CONTRACTOR e 11 THE SUCTION AND LIQUID LINES SHALL BE TYPE "L" HARD DRAWN COPPER TUBING, INSULATED WITH MINIMUM OF 1/2" ARMAFLEX OF EQUAL SOFT COPPER TUBING MAY BE USED IF NECESSARY TO INSTALL MAY K C LINES AROUND OBSTRUCTIONS SHARP PINCH CAUSING A RESTRICTION. AUOSE LONG RADIUSSELBOWSBIWHENEVER GRILLE AND DIFFUSER SCHEDULE POSSIBLE WITH SHORT RADIUS ELBOWS FOR THE TRAP AT THE BOTTOM Architects - Engineers, P.0 OF SUCTION RISERS BRAZE ALL CU TO CU JOINTS WITH SILFOS-5 SYM MFR & MODEL # SIZE CFM MATERIAL BORDER TYPE FINISH REMARKS BIRDSCREEN 12250 East Iliff Avenue, Suite 302 EQUIVALENT BRAZING MATERIAL. DO NOT USE SOFT SOLDER. SUCTION LINES TO BE SUPPORTED A MINIMUM OF EVERY 8'. LIQUID LINES A WALL EXHAUST FAN- MODEL AM10R Aurora, Colorado 80014-1253 MINIMUM OF EVERY 6' S= TITUS #272RS 16"X16" 2000 STEEL 1 #26 WHITE REFER TO SCHEDULE 3037506999 it k cde FAX 303 750 0236 12. INSTALL EQUIPMENT AND RUN PIPES AND DUCTS PARALLEL WITH OR AT Email kdcdenverQkdcarchitects corn RIGHT ANGLES TO THE WALLS OF THE BUILDING UNLESS SHOWN /R—G\ TITUS 271 RL 20"X14" 2000 PROVIDE AND INSTALL FRAMING Website. www kdcarchitects corn OTHERWISE ON THE DRAWINGS PARALLELED RUNS SHALL BE STRAIGHT 1 # STEEL 1 #26 WHITE FOR ROUGH OPENING. AND TRUE WITH OFFSETS UNIFORM AND SYMMETRICAL EG 13. CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER CONSTRUCTION NA NA NA NA NA TIME AS NOT TO DISTRACT FROM NORMAL WORKING CONDITIONS eA TITUS #355ZR 16"X16" 440 STEEL 1 #26 WHITE AT&T WIRELESS SERVICES 14. CONTRACTOR SHALL VERIFY PIPE SIZE WITH MANUFACTURER'S REP FOR PROJECT OVERALL PIPING RUN. 2101020 003 ------r-F\T GRAVITY BACKDRAFT M • 1 DAMPER SCHEDULE DAMPER DP SYM MFR & MODEL # SIZE MATERIAL ACTUATOR VOLTAGE �I POWER EXHAUSTER MKS RUSKIN FSDR25 14"x14" STEEL P150 120 N C SPRING OPEN/POWER CLOSE 12 x 12 DUCT i� NOi DATE ISSUE /E—D\ ION CONTROLSEQUENCE' A RUSKIN FSDR25 14"x14" STEEL P150 120 N.0 SPRING OPEN/POWER CLOSE ��, GASKET 1 0303.00 CLIENT REVIEW/ZONING �I� 2 04.21.00 ZONING * CONTRACTOR SHALL VERIFY DAMPER SIZE REQUIRED. SECURE & CAULK 3 0531.00 ZONING REVISION 1. THE AIR CONDITIONING UNITS SHALL DUTY CYCLE. AIR HANDLER ------ ENTIRE PERIMETER 4 06.19.00 ZONING REVISION *DAMPER LISTED UL 555S, 1-1/2 HOUR RATED, VERTICAL OR HORIZONAL USES. 5 06 23 00 RF REVISION 2 THE AIR CONDITIONING UNIT FAN WHICH IS LEAD SHALL RUN CONTINUOUSLY. 6 06.2700 ZONING REVISION *F/S DAMPER LOCATED AT RATED CEILING. 07.11.00 OWNER REVISION 3 UPON A CALL FOR COOLING, THE LEAD AIR CONDITIONING UNIT SHALL PROVIDE /DAMPER D-1 MOTORIZED ISO 8 10 19 00 CONSTRUCTION REVISION COOLING IF THE SPACE TEMPERATURE RISES 3'F ABOVE SET POINT, THE AIR TEC SCREWS (3 PER SIDE) EG N.C. SPRING OPEN ON/ REVISION UNIT WHICH IS THE LAG UNIT SHALL PROVIDE COOLING WHEN 14x14 SHEET METAL g 11 0700 CONSTRUCTION/REVISION THE ORIGINAL SET POINT IS REACHED, THE LAG AIR CONDITIONER SHALL CEASE 1 ON HYDROGEN DETECTION SKIRT THRU WALL OPERATION. LA— RETURN PLENUM ��,p0 REG�sl 4 THE COOLING SET POINT FOR THE AIR CONDITIONING EQUIPMENT IS 72'F, ���;'•ZN D•c ADJUSTABLE CONCRETE FLOOR EXISTING EXTERIOR WALL �'; ® • 5 UPON HYDROGEN DETECTION AC-1, AC-2, CU-1, AND CU-2 SHALL SHUT DOWN 525J OPERATIONS EF-1 SHALL START AND MAD-1 SHALL OPEN. 1/2" DIA ANCHORS, �,c�' ���� 4 REQUIRED Fs' •� 2 WALL MOUNTED EXHAUST FAN s/ONAL�-� 1 SECTION AA M-1 NOT TO SCALE m All drawings and written material contained hereIn may not be duplicated used or disclosed M-1 NOT TO SCALE without the written consent of the architect THERMOSTAT SUBBASE sUPP�� WEST VAI L AT qT DISCHARGE PLENUM FABRICATE �1'-8 W1 W2 RC RH Y1 Y2 1�'S URN 1'� SUP PIY 2077 N. FRONTAGE RD. FROM 18 GA SHEET METAL ,1�5 9�� pT AT VAIL, COLORADO 81657 (FINISH TO MATCH A H ) r 1 ' RETURN 1'-6'F- R Y BR W BK RH Y1 rY2TW 1 W2 RC TYPROF (4) SIDES 1/8" 0 D. FLARE POP RIVET ° 0 SG MARVAIR CONTROLLER #LL357 jo ° 7'-5" MAX ° 45' GUSSET ° SCREW PLENUM TO FLANGE ON A.H - - r - - - ° I° 18 GA. 18 GA SHEET METAL (8 PLACES) - 2 1/2"x2 1/2 x6 LONG JOINT ROOF-TOP ANTENNAS & Q Q Q I ANGLE 14 GA ANCHOR TO WALL WITH EQUIPMENT ROOM� I 3/8" WOOD SCREWS IN WOOD BLOCKING, i- - ATTACH TO A.H. WITH 2 - #12 TECS. I r _ i- - - - -i (EACH SIDE) /� I I I r I I �ISHEET TITLE RG RETURN PLENUM FABRICATE �C W EY TOP TAB FROM FINS H GA TOSMATCH A.H ) NOTES SINGLE 45' DOUBLE 45' JOINT CUT END MECH DETAILS, I A/C #1 A/C #2 90�TAB AND SCHEDULES M-I 90' TAB 1'-11 1/2"� 1�_g°° - - - FACTORY WIRING 90, END SECTION 90' 90' - FIELD WIRING BY MECH CONTR Z , * VERIFY DIMENSION AS REQUIRED TO MATCH UNLESS OTHERWISED NOTED 45 1/8" RIVET OR 5 STAR SMS SHEET NUMBER AIR HANDLER FURNISHED. 3 DISCHARGE AND RETURN PLENUMS 4 ENVIRONMENTAL CONTROL PANEL SCHEMATIC (ECP) 5 PLENUM DETAIL M-1 NOT TO SCALE M-1 NOT TO SCALE M-1 NOT TO SCALE � * VERIFY DIMENSION AS REQUIRED TO MATCH M 1 AIR HANDLER FURNISHED 24445-7DE-2056-M01-9 low AT&T AT&T Wireless Services 8 SUITE C-1 1001 16TH. STREET 16 22 DENVER, COLORADO 80265-0003 4 12 13 LOW AMBIENT RETROFIT SHALL BE BUT NOT LIMITED T O 13 8 1O O WALL PENETRATION 1 g 20 EF-1 I I TXV• TAYTXVAOH5C (5-6 TON ONLY) SOLENOID VALVE. VERIFY WITH TRANE CONTROLER: BAYLOAM102A (XE 1200 (TTP) 10 ONLY) TELCO CONTROLER. BAYLOBOX01A (TTP060100A ONLY) gp ED-1 CONDENSER MOTOR. BAYMOTR3068 (TTP060C100A ONLY) 24V CABLE I BATT NOTE AC-1 TRAY —1 10 9 LISTED ABOVE ARE GENERAL PERAMITERS TO RETROFIT SPLIT SYSTEMS TO OPERATE TO MIN —201F ' CONTRACTOR IS RESPONSIBLE TO VERIFY INFORMATION ABOVE AND CONTACT A TRANE MANUFACTURING REP TO 2 7 I F OBTAIN CORRECT EQUIPMENT TO PROVIDE ABOVE PERFORANCE CONTRACTOR SHALL PROVIDE LOW AMBIENT C. 24V EQUIPMENT AND LABOR IN CONSTRUCTION BID 21 14 I LAF-1 BA 11 PANEL 200A _j LAF-0 HVAC KEY NOTES SUITE A AT&T EQUIPMENT KDC O ROOF MOUNTED CONDENSERS INSTALL ON ROOF AS PER MANUFACTURER'S INSTRUCTIONS MANUAL TRANS ROOM Architects — Engineers, PC. REFER TO ARCH DTLS OF A6 FOR ADDITIONAL INFORMATION AND LOCATIONS I SW RCF-0 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-12 <T> INSTALL AIR HANDLING UNITS PER MANUFACTURER'S INSTRUCTIONS AND PER DETAILS INDICATED F ON M1 DRAWINGS. 303 750 6999 FAX 303 750..00 236 Email kdcdenver @kdcarchitects com GPS 3 AT&T RADIO EQUIPMENT PROVIDED & INSTALLED BY OTHERS 2424 SUITE B Website. www kdcarchitects.com O DISCON'T SWITCH O4 REFRIGERANT LINES UP AND THROUGH EXISTING WALL TYPICAL FOR 2 CIRCUITS, 4 PIPES AT&T WIRELESS SERVICES O5 ENVIRONMENTAL CONTROL PANEL PROVIDE AND INSTALL ALL WIRING FROM MARVAIR RCF-1 GPS PROJECT • CONTROLLER SEE SCHEMATIC ON M-1 FOR CONTROL WIRING MOUNT 66" A F F 2424 OHIGH AND LOW TEMPERATURE ALARM THERMOSTATS- PROVIDE AND INSTALL TWO (2) HONEYWELL FUTURE 2101020 003 FARM—O—STATS T631A1006. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND SIGNAL WIRING _ 3�' TO EXTERNAL ALARM PANEL MOUNT AT 66 A.F.F. , , • DISCON'T RCF-2 7O REFERENCE DETAIL 3/M-1 SWITCH L tJ CHECKED BY 8O REFERENCE DETAIL 2/M-1 FOR NEW EXHAUST FAN EF-1. MKS F DATE ISSUE O NEW 1402 EXHAUST DUCT REFERENCE 2/M-1 i PANEL 200A AIF 1 0303.00 CLIENT REVIEW/ZONING 10 TRANSITION FROM FAN COLLAR TO LISTED EXHAUST DUCT SIZE. 2 2 0421.00 ZONING 6 I FUTURE � ---Ft— 3 0531 00 ZONING REVISION <> CEILING MOUNTED HYDERGEN SENSOR, RE ELECTRICAL DWG FOR WIRING AND OPERATION OT I 4 06 19 00 ZONING REVISION CABLE TRAY 5 0623.00 RF REVISION A/C 6 06 27 00 ZONING REVISION < 12> NEW LIQUID AND SUCTION LINE CONTRACTOR SHALL SIZE PER MANUFACTURE INSTRUCTIONS. 5 PANEL 0711 00 OWNER REVISION SUPPORT PIPING PER STATE AND LOCAL CODE. 8 10.1900 CONSTRUCTION/REVISION T AIF 9 11.07.00 CONSTRUCTION/REVISION 13 FIRE SEAL ALL PIPING WALL PENETRATION TYPICAL I I 1 6 FUTURE L� 14 CONDENSATE DRAIN, RUN TIGHT TO STRUCTURE, TERMINATE AT CLOSEST INDIRECT RELAY \OQ;�Q�H pGCOO DRAIN PROVIDE CONDENSATE PUMP EACH UNIT. <3> CONTRACTOR SHALL VERIFY LIQUID AND SUCTION PIPING RUN, PROVIDE AND INSTALL — PCs 3 CDPD �r 5J. SUPPORTS PER STATE AND LOCAL CODES EXT ALARM GROWTH �p:. 0�-100•'- 16 CONTRACTOR SHALL VERIFY PIPING WALL PENETRATION, TYPICAL OF 4 LINES PANEL �' ••.NA, F`�S�ONAL ECG LL- <a> NOT USED ® All drawings and written material contained NEW 14x14 MAKE—UP AIR DAMPER AND THRU WALL DUCT. TERMINATE BELLOW CEILING MAD-2 PCS 3 herein may not be duplicated used c disclosed 18 SHALL SPRING OPEN ON START OF EF-1 AND POWER CLOSE 13 PRI without the written consent o� the architect. AC-2 <3> ED-1 AND MAD-2 FIRE DAMPER NORMALLY CLOSED, ON START OF EF-1 DAMPER SHALL SPRING ® • OPEN TO PROVIDE MAKEUP AIR 2 7 <9> FIRE DAMPER IS RUSKIN FSDR, 1-1/2 HOUR RATED, WITH ROUND DUCT TRANSITION AND 120V BLADE OPERATOR AIR STREAM LOCATION DAMPER NORMALLY CLOSED, UPON EF-1 WEST VAI L START DAMPER SHALL SPRING OPEN. ED-1 AND MAD-2 21 CONTRACTOR SHALL RELOCATE EXISTING EXHAUST FAN AND DUCT WORK TO REVISED REST ROOM 2077 N. FRONTAGE RD. CONTRACTOR SHALL VERIFY RELOCATION AND MATERIAL REQUIRED FAN SHALL BE SWITCH OPERATED 14 VAIL, COLORADO 81657 22 RUN LIQUID AND SUCTION UP WALL TO CONDENSER LOCATED ON ROOF REFERENCE A-5 FOR 18 MAD-1 LOCATION 19 20 v NOTE - CONTRACTOR PRIOR TOBIDTO REVIEW AT&T SPECIFICATIONS I ROOF-TOP ANTENNAS & TOS & ALARMS EQUIPMENT ROOM TRANS REPRESENTATIVE JOE BUSHARD 303-228-2831 303-228-2828 FAX 445 BRANT DENVER, COLORADOT 80204 MECHANICAL P LAN (:D_C0NSTRUCTI0N/E0UIP. PLAN SCALE 1/2" — 1'-0" SHEET -NUMBER 0 2' 4' 61 t r� SCALE FEET 24445-7DE-2056—MO2-9 ELECTRICAL SPECIFICATION GENERAL NOTES NOTE POWER AND TELCO TO BE 1 ELECTRICAL CONTRACTOR SHALL VERIFY VOLTAGES AND HORSE— COORDINATED WITH OWNER, 1 THE ELECTRICAL INSTALLATION WORK SHALL COMPLY WITH ALL POWER RATINGS OF ALL MECHANICAL EQUIPMENT. AT&T PROJECT MANAGER AND LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES 2. PRIOR TO INSTALLING ANY ELECTRICAL WORK, THE ELECTRICAL UTILITY COMPANIES AT&T APPLICABLE TO ELECTRICAL WORK. CONTRACTOR SHALL VERIFY EXACT LOCATIONS AND REQUIREMENTS 2. ELECTRICAL CONTRACTOR SHALL VISIT JOBSITE AND VERIFY ON THE JOB AND BY REFERENCE TO• ARCHITECTURE, MECHANICAL EXISTING CONDITIONS BEFORE BIDDING AND SHALL INCLUDE AND EQUIPMENT SUPPLIERS DRAWINGS SHOULD THERE BE ANY AT&T Wireless Services IN HIS BID THE NECESSARY COSTS TO CONSTRUCT THIS PROJECT QUESTION OR PROBLEM CONCERNING THE NECESSARY PROVISIONS SUITE C-1 IN ACCORDANCE WITH INTENT OF THE ELECTRICAL DRAWINGS, TO BE MADE, PROPER DIRECTIONS SHALL BE OBTAINED BEFORE DENVER,1, TH STREET , COLORADO 80265-0003 SPECIFICATIONS, AND ALL APPLICABLE CODES PROCEEDING WITH ANY WORK. 3 ALL MATERIAL AND EQUIPMENT FURNISHED AND INSTALLED UNDER 3. OUTLET AND JUNCTION BOXES SHALL BE SIZED PER CODE FOR THE THIS CONTRACT SHALL BE NEW, FREE FROM DEFECTS, AND SHALL QUANTITY OF WIRES THEY CONTAIN SEE ARTICLE 370-6 OF N E C. BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL PROVIDE ADDITIONAL BOXES AND EXTENSION RINGS AS REQUIRED ACCEPTANCE BY OWNER OR HIS REPRESENTATIVE. SHOULD ANY TROUBLE DEVELOP DURING THIS PERIOD DUE TO FAULTY WORK- MANSHIP, MATERIAL OR EQUIPMENT, THE CONTRACTOR SHALL , FURNISH ALL NECESSARY MATERIAL AND LABOR TO CORRECT THE TROUBLE WITHOUT COST TO THE OWNER. T TELEPHONE SERVICE 4. ALL WORK TO BE EXECUTED IN WORKMANLIKE MANNER AND SHALL E ELECTRICAL SERVICE I PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. CONDUIT RUN EXPOSED 5 ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE LISTED (hash marks indicate no of wires, less grid ) BY UNDERWRITER'S LABORATORIES — — — — — — CONDUIT RUN CONCEALED 6. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ------------ GROUNDING CONDUCTOR CUTTING AND PATCHING RELATED TO ELECTRICAL WORK, UNLESS NOTED OTHERWISE AND COORDINATED WITH THE GENERAL O 5/8" DIA. X 8'-0" L, COPPER—CLAD m CONTRACTOR. STEEL GROUND ROD 7. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK WITH GROUNDING CONNECTION —� MECHANICAL AND ARCHITECTURAL PLANS. THE REQUIREMENTS OF m KDC ALL EQUIPMENT ACTUALLY BEING INSTALLED SHALL BE VERIFIED TRANSFER SWITCH PRIOR TO INSTALLING THE ELECTRICAL WORK L J Architects — Engineers, P C 12250 East Iliff Avenue, Suite 302 8. ALL BRANCH CIRCUIT CONDUCTORS SHALL BE COPPER TYPE "THHN" DISCONNECT SWITCH m EXISITNG PROPERTY LINE Aurora, Colorado 80014-1253 X12, & X10 SOLID, #8 AND LARGER STRANDED. — — — — — — — — — — — — — 303 750 6999 FAX 303.750 0236 Email kdcdenver®kdcarchitects corn 9. ON COMPLETION OF THE WORK, THE INSTALLATION SHALL BE FREE __oo— CIRCUIT BREAKER m Website. www.kdcarchitects corn FROM GROUNDS AND SHORT CIRCUITS. M ELECTRIC MOTOR 10. ELECTRICAL CONTRACTOR SHALL FURNISH AS—BUILT DRAWINGS TO O THE ARCHITECT ON COMPLETION OF THE JOB. m - AT&T WIRELESS SERVICES — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — ® ELECTROMAGNETIC RELAY OR MOTOR STARTER I PROJECT 11 . ELECTRICAL WORK SHALL INCLUDE ALL LABOR, MATERIALS AND I I , EQUIPMENT REQUIRED, INCLUDING BUT NOT LIMITED TO COMPLETE UTILITY EASEMENT 204033 003 ELECTRICAL SYSTEMS POWER AND LIGHTING, TELEPHONE CONDUIT FS-1 ELECTRICAL METER I - SYSTEM, SIGNAL SYSTEMS, PANELBOARDS (S), CONTROL WIRING, I i SMT GROUNDING, CONDUIT ONLY SYSTEMS, ETC., AS INDICATED ON ® GENERATOR RECEPTACLE m I f : MECHANICAL & ELECTRICAL DRAWINGS AND/OR REQUIRED BY GOVERNING CODES J— GROUND 10' ELECTRICAL EASEMENT MKS M NO DATE ISSUE 12 RACEWAYS SHALL BE RIGID STEEL CONDUIT- ZINC—COATED OR SHERARDIZED HEAVY WALL ® ELECTRICAL FEEDER IDENTIFICATION EXISTING U.G I 1 03 03 00 CLIENT REVIEW/ZONING AS MANUFACTURED BY REPUBLIC,TRIANGLE OR EQUAL TELCO RUN 10' ELECTRICAL EASEMENT 2 04.21.00 ZONING RIGID POLYVINYL CHLORIDE CONDUIT (PVC) HEAVY WALLS SCHEDULE ELECTRICAL PANEL 3 0531 00 ZONING REVISION 40 AS MANUFACTURED BY CARLON ELECTRICAL, VISQEEN OR EQUAL. DUPLEX RECEPTACLE 20A, 120V I PROPOSED MOBILE 4 06 1900 ZONING REVISION ELECTRICAL METALLIC TUBING (EMT). ZINC—COATED THIN WALL AS � —+ GENERATOR RECEPTACLE 5 06.23.00 RF REVISION MANUFACTURED BY TRIANGLE, REPUBLIC OR EQUAL QUAD RECEPTACLE 20A, 120V 6 06 27 00 ZONING REVISION SWITCH 2OA-1 P 0711 00 OWNER REVISION - 13. FUSE TYPE SHALL BE BUSSMANN FRN—S TYPE FUSES S — — — — — 8 10 19 00 CONSTRUCTION/REVISION r ( 11 0200 CONSTRUCTION/REVISION - 14. PROVIDE ENGRAVED PLASTIC LABELS TO IDENTIFY ALL PANELBOARDS, O ELECTRICAL MOTOR TV RISE I TIE WALL i XFMRS , DISTRIBUTION PANELS ,DISCONNECT SWITCHES� TRANSFER r� �PpO RE�jf o0 SWITCHES. LABELES SHALL READ IN THIS FASHION A" 208Y/120V OD MOTORIZED DAMPER 20 3W, 200A, CKT BKR OR FUSES TYPE AND SIZES ,� EXISTING PAD MOUNTED TRANS— PROPOSED O I I �:• �•� 2 X 4 FLORESCENT RECESSED LIGHTING FIXTURE TRANSFORMER 300 KVA, FORMER 15253 • 15 E.0 SHALL VERIFY AND TEST GROUND TO SOURCE TO A MAXIMUM 3�, SEC 208/120V ELEC. RUN -o OF 5 OHMS. IF THE GROUND TEST DID NOT ACHIEVE THE 5 OHMS Q KEYLESS 24 V DC SURFACE MOUNT FIXTURE m ( PROPOSED —_ -- �°�FSS•,••••••••0��``� ` OR LESS. E.0 SHALL NEGOTIATE WITH OWNER TO PROVIDE © — — — � I— — — CT CAB O I I 1 1 I �oNAL��v ADDITIONAL GROUNDING AS REQUIRED D SMOKE DETECTOR EXISTING U G ELECTRICAL RUN m I F `� PROPOSED I I I I UTILITY CO. I I I I I I m All drawings and written material contained 16. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REQUESTING H❑ HYDROGEN I \ METER L--� L7P,1 L —J herein may not be duplicated used or disclosed APPLICATION OF SERVICE ON BEHALF OF AT&T WIRELESS. I I F without the written consent of the architect OM ELECTRICAL MOTOR I m Ld p MOTORIZED DAMPER z I I OPOSED I _ O SUITE A Qg NDEN SER m AT&T UNITS ON ROOF SUITE A EQUIPMENT WEST VA L o � m I F B 0. = FURNISHED AND INSTALLED BY OTHER TRADES OR z CD -� 2077 N. FRONTAGE RD. CONTRACTOR NOTES OWNER, CONNECTIONS BY ELECTRICAL CONTRACTOR LZ I I DUMPS TER PROPOSED TELCO RUN — I VAIL, COLORADO 81657 F.B.0.E. = FURNISHED BY OTHER TRADES OR OWNER, x — INSTALLATION AND CONNECTION BY ELECTRICAL CONTRACTOR F.B.M. = FURNISHED BY MECHANICAL. m 1 BEFORE SUBMITTING BID, VERIFY EXISTING SITE CONDITIONS, C 0. = CONDUIT ONLY — — — — — — — — — ELECTRICAL SERVICE REQUIREMENTS AND THE EXACT SERVING EMT. = ELECTRICAL METALLIC TUBING (THIN WALL) PVC = SCHEDULE 40 PVC CONDUIT — T T T T T UTILITY P OINTS OF CONNECTION RGSC = RIGID GALVANIZED STEEL CONDUIT �' PROPOSED TELCO BD. 2 THE ELECTRICAL CONTRACTOR (E.C.) SHALL FURNISH AND PAY N.L = MOUNTED HT I I I ROOF—TOP ANTENNAS 8c FOR ALL PERMITS AND RELATED FEES. W P = WEATHERPROOF EXISTING U.G � NG TELCO EQUIPMENT ROOM 3 UNLESS SPECIFICALLY NOTED OTHERWISE, ALL ELECTRICAL U.O.N. = UNLESS OTHERWISE NOTED. TELCO RUN I D G. OR GRID. = GROUND. MATERIALS, EQUIPMENT AND WORK, SHOWN ON THESE PLANS N. OR NEUT. = NEUTRAL I � ARE NEW TO BE PROVIDED AND INSTALLED BY THE ELECTRICAL SN = SOLID NEUTRAL SHEET TITLE '' CONTRACTOR. A OR AMP = AMPERE. 4 E C SHALL FURNISH AND INSTALL ALL SWITCHES, CONDUIT, KW. = KILOWATTS. WIRES, BOXES, LIGHT FIXTURES (INCLUDING LAMPS), SERVICE W. = WATTS ELECTRICAL SPEC., DEVICES, RECEPTACLES, SWITCHBOARDS AND PANELBOARDS, ETC L.V. = LOW VOLTAGE. NOTES, SYMBOL LIST REQUIRED FOR A COMPLETE AND OPERATING ELECTRICAL SYSTEM. = PHASE. C L. = CURRENT LIMITING. NOTES, SYMBOL LIST, 5. E C SHALL BE RESPONSIBLE FOR CONFORMANCE WITH THE D.E. = DUAL ELEMENT NATIONAL ELECTRICAL CODE, STATE OF COLORADO ELECTRICAL AFG = ABOVE FINISHED GRADE ABBREVIATIONS AND BFG = BELOW FINISHED GRADE SAFETY ORDERS, ALL LOCAL CODES AND ORDINANCES AND ALL AFF = ABOVE FINISHED FLOOR ELECTRICAL SITE PLAN — FIRST FLOOR OTHER ADMINISTRATIVE AUTHORITIES HAVING JURISDICTION OVER XFMR = TRANSFORMER. 1 SCALE 1/4" = 1'-0" SHEETNUMBER THIS WORK C.B. = CIRCUIT BREAKER. CKT. = CIRCUIT 6. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONAL/LOCATION SW. = SWITCH. INFORMATION RELATING TO THE ELECTRICAL DRAWINGS. TRANSF. SW = TRANSFER SWITCH FA = FIRE ALARM. RECPT = RECEPTACLE. M C. = MECHANICAL CONTRACTOR E.0 = ELECTRICAL CONTRACTOR 24445-7DE-2056—EO 1— G C. = GENERAL CONTRACTOR Ann— AT&T AT&T Wireless Services SUITE C-1 1001 16TH STREET DENVER, COLORADO 80265-0003 DEMOLITION PLAN KEYED NOTES O DISCONNECT AND REMOVE EXISTING BASEBOARD HEATERS AND ASSOCIATED WIRING O DISCONNECT AND REMOVE EXISTING SURFACE MOUNTED LIGHTING FIXTURES AND ASSOCIATED WIRING CIRCUIT BREAKER TELEPHONE 0 DISCONNECT AND REMOVE EXISTING WALL MOUNTED RECEPTACLES AND ASSOCIATED WIRING ELECTRIC HOT WATER ® DISCONNECT AND REMOVE EXISTING TELEPHONE OUTLETS TRANSFORMER AND ASSOCIATED WIRING —r EXHAUST FAN SWITCH W/LIGHT 50 DISCONNECT AND REMOVE EXISTING LIGHT SWITCHES AND ASSOCIATED WIRING 1 2 O 3 © DISCONNECT AND REMOVE EXISITNG ELECTRIC PANEL AND 1 ASSOCIATED WIRING INSTALL THIS PANEL IN NEW LOCATION AS INDICATED ON THE DRAWING. ESTABLISH NEW PANEL D FEEDER (THE SAME SIZE AS EXISTING) AND INSTALL NEW HOMERUNS TO THE PANEL M I I 3 I 0 REMOVE EXISTING WIRING OF EXISTING WATER HEATER TO BE I RELOCATED IN RESTROOM. RELOCATE THE WATER HEATER K C 8 I DISCONNECTING MEANS AND CONTOL INSIDE TOILET AREA. TRANSFORMER 4 I 3 ESTABLISH NEW HOME RUN TO THE ELECTRIC PANEL. Architects — Engineers, P C \ I I 12250 East Iliff Avenue, Suite 302 �O 3 5 I I ® REMOVE EXISTING INCANDESCENT LIGHTING FIXTURES, Aurora, Colorado 80014-1253 �j AND ASSOCIATED WIRING. 303 750 6999 FAX 303 750 0236 7 — I — J I Email kdcdenver @kdcarchitects corn L = __ --L— � I O REMOVE EXISTING EXHAUST FAN, AND Website. www kdcarchitects corn \ 5 ASSOCIATED WIRING AND CONTROLS. AT&T WIRELESS SERVICES _ � I PROJECT NUMBER GENERAL NOTES 204033 003 4 OEM will L - - - - - - — 3 - - SMT F_ - - - - - � - - - SUITE B I 5 1. COORDINATE DEMOLITION PROCESS WITH GENERAL CONTRACTOR II AND OWNER I 4 MKS 2. ELECTRICAL EQUIPMENT TO BE REUSED FOR NEW CONSTRUCTION x �x — x— x�—x —x —� SUITE AT&T A — — —7 3 EQUIPMENT SHALL BE CLEANED, INSPECTED AND PROPERLY STORED. x EQUIPMENT 1 030300 CLIENT REVIEW/ZONING / 2 3 EXISTING ELECTRICAL EQUIPMENT NOT FLAGGED BY KEY NOTES IS x x ROOM i TO REMAIN. PORTION OF WIRING TO BE REUSED FOR NEW WIRING 2 0421 00 ZONING SHALL REMAIN IN PLACE. 3 0531 00 ZONING REVISION 1 5 3 4 06 1900 ZONING REVISION DUMPSTER ®` — — — — — — — 11 — — — — — — — — — — — — — — — — — 5 06 23 00 ZONING REVISION _ 6 06 27 00 ZONING REVISION x C — I F - - - - - - - - - - 071100 OWNER REVISION 8 10.1900 CONSTRUCTION/REVISION x x I 3 9 11 0200 CONSTRUCTION/REVISION 3 II 4 1 2 El I I I o��,p0 REG�sl Off, .• H D� • F 2 5253 LL 5 / c� � o,�L• • N 7 00. ��c, sees•••C?\ I T s�ONAL I I <> 3 li it 5 Q All drawings and written material contained herein may not be duplicated used or disclosed without the written consent of the architect I I I WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 I I I I I ROOF-TOP ANTENNAS & EQUIPMENT ROOM � SHEET TITLE I I I DEMOLITION PLAN DEMOLITION P LAN 1 SCALE 1/8" = 1'-0" 2 F 24445-7DE-2056—EO2-9 POWER PLAN KEYED NOTES- GROUNDING PLAN KEYED NOTES _.._ 1& AT&T EQUIPMENT BY OTHERS OPANEL "A" SHALL HAVE A 225 AMP BUS, 1 PHASE, 3W, CIRCUITS, MAIN C/BREAKER 200A-2P, NEMA TYPE 1 ENCLOSURE, SURFACE O INTERNAL C"HM O" BENDING RADIUS US( SHALL BE MOUNTED AT 96" A F F USING NYLON CLIPS GROUND MOUNTED, SQUARE D NQOD OF EQUAL AT&T O FUTURE ELECTRICAL EQUIPMENT. POWER PLAN KEYED NOTES CONTINUED O SERVICE DISCONNECT SWITCH 400A-2P, 120/240V < SURGE ARRESTOR. JOSLYN #1456-08 (OR APPROVED EQUAL) MOUNTED NEXT TO PANEL "A" O USE COMPRESSION CONNECTION TO "HALLO" CONDUCTOR AT&T Wireless Services 30 EXISTING ELECTRIC PANEL INSTALLED TO NEW LOCATION SUITE C-1 O AIR CONDITIONER UNIT, REFER TO MECHANICAL DRAWINGS FOR SCHEDULE. 1001 16TH STREET O6 CONDENSER UNIT ROOF—MOUNTED NOT SHOWN SEE MECH DRAWINGS. 31 ESTABLISH NEW HOME RUNS FROM EXISTING BASEBOARD HEATERS TO RELOCATED EXISTING PANELBOARD USING O #6 CU TO METAL DOOR FRAME. DENVER, COLORADO 80265-0003 ( )� EXISTING WIRE SIZES USE EXISTING CIRCUIT BREAKERS O5 #6 CU TO AT&T EQUIPMENT (TYPICAL) < DUPLEX RECEPTACLE ® 12" A F F UNLESS OTHERWISE NOTED (TYP 5) <9> ESTABLISH NEW HOME RUNS (2#12 & 1#12G) 1/2" C FROM RECEPTACLES TO RELOCATED EXISTING PANELBOARD #2 CU FROM RADIO EQUIPMENT GROUND BUS TO MASTER GROUND BAR. OEXTERNAL ALARM PANEL O #6 CU TO CABLE LADDER GROUND WIRE. ALARM PANEL IS PROVIDED & INSTALLED BY LUCENT CONTRACTOR SHALL PROVIDE 1-1/2 CONDUIT FROM ALARM PANEL TO NEAREST CABLE LADDER EC SHALL RUN ( 2 #22 AWG —1/2" CONDUIT FROM ALARM PANEL TO EACH OF THE FOLLOWING ITEMS O7 MASTER GROUND BAR. UNLESS OTHERWISE NOTED. 1. SMOKE/HEAT DETECTOR O8 (1#1/0 CU, THHN) 1/2"C FROM MASTER GROUND BAR TO 40OA-2P SERVICE DISCONNECT 2. SURGE ARRESTOR ALARM CONTACTS SWITCH GROUND BAR. 3 MAGNETIC DOOR ALARM CONTACTS 4 HIGH TEMPERATURE THERMOSTAT O (1#1/0 CU THHN) 1/2" CONDUIT FROM 40OA-2P SERVICE DISCONNECT SWITCH ' 5. LOW TEMPERATURE THERMOSTAT 6. RECTIFIER ALARM TO GROUND ROD OF EXTERIOR GROUND RING 7 POWER FAILURE RELAYS 8 DC POWER FAILURE RELAYS <8> #6 TO WAVE GUIDE ENTRY PLATE LOCATION RE- A-3 OTELEPHONE TERMINAL BACKBOARD- 4'x8'x3/4" FIRE RETARDANT PLYWOOD SEE CONSTRUCTION KEY NOTE #5 ON SHT A-2 <> HVAC EQUIPMENT TO BE GROUNDED BY FEEDER GROUND WIRE. 10 QUAD RECEPTACLE FOR TELEPHONE TERMINAL MTD ® 6'-0" A F F <9> GROUNDING CONDUCTOR ® TO BE CONNECTED TO COLD WATER SERVICE PIPE 11 TWO—PIECE MAGNETIC DOOR ALARM ADEMCO #39-2, (OR APPROVED EQUAL) RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL SEE NOTE<g> <g> #6 CU TO EXHAUST FAN EF-1 METAL DUCT. <S> ENVIRONMENTAL ALARMS HIGH & LOW TEMPERATURE ALARMS MTD. ON WALL RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL 14 GROUND ROD 5/8" DIA X 8" L COPPER—CLAD STEEL SEE NOTE K C <9> POWER FAILURE RELAYS. INSTALL POWER FAILURE RELAYS IN 6"x6"x4" ENCLOSURE. MOUNT ON WALL NEXT TO PANEL "A". ROUTE ALARM CONDUCTOR TO EXTERNAL ALARM PANEL. Architects — Engineers, P.0 12250 East Iliff Avenue, Suite 302 <3> ENVIROMENTAL CONTROL PANEL RUN SIGNAL WIRE TO EXTERNAL ALARM PANEL AND PROVIDE POWER WIRING AS SHOWN GROUNDING GENERAL NOTES Aurora, Colorado 80014-1253 303 750.6999 FAX 303 750.0236 15 GENERATOR RECEPTACLE, COORDINATE WITH PROPERTY MANAGER FOR EXACT LOCATION ON EXTERIOR OF THE BUILDING LIGHTING PLAN KEYED NOTES Email kdcdenver@kdcarchitects com REFER TO ONE—LINE DIAGRAM (E-1) FOR WIRING INFORMATION WALL MOUNTED 3'-0" A F F 1 ALL DETAILS ARE SHOWN IN GENERAL TERMS Website, www kdcarchitects.com ACTUAL GROUNDING INSTALLATION AND 16 EXHAUST FAN WITH FIRE/SMOKE DAMPER. REFER TO MECHANICAL DRAWING FOR TYPE AND POWER REQUIREMENTS. SEE O ALL LIGHTING WIRING SHALL BE COPPER #12 AWG WITH THHN INSULATION RATE 600V, 90-C CONSTRUCTION MAY VARY DUE TO SITE SPECIFIC FAN CONTROL DIAGRAM (E-4) CONDITIONS O2 PROVIDE KEYLESS PORCELAN FIXTURE W/ 24V DC LAMP FOR EMERGENCY LIGHTING (TYP OF 6) 2 ALL GROUNDING CONDUCTORS SHALL BE TINNED COPPER. AT&T WIRELESS SERVICES 17 UTILITY CO. METER 400A, 30, 120/208V ® CONNECT TO 24V DC RECTIFIER CIRCUIT BREAKER AND PROVIDE SWITCH BY DOOR SO THAT UNLESS NOTED OTHERWISE. • - • • LIGHTING FIXTURE IS NORMALLY SWITCHED ON BY TECHICAN DURING POWER OUTAGE ONLY. 18 MANUAL TRANSFER SWITCH 2OOA-2P, SN, 120/240V. REFER TO ONE-LINE DIAGRAM ON E-1 3. GROUND SYSTEM MUST BE TESTED BY CONTRACTOR AND 2101020 003 MOUNTING HEIGHT 5'-0" A.F F < PROVIDE IONIZATION SMOKE/HEAT DETECTOR FIRE-LINE 120V AC OR EQUAL MOUNT TO STRUCTURE SHALL HAVE A RESISTANCE OF 5 OHMS OR LESS DUE, ., ABOVE CEILING GRID ROUTE ALARM CONTRACTS TO ALARM PANEL ROUTE AUXILARY CONTACTS TO SUBMIT AN INDEPENDENT TESTING REPORT. A.C. UNITS FOR UNIT SHUT DOWN. W20 T CABINET 400A, 120/208V, 30 ® 4 NOTIFY ARCHITECT/ENGINEER IF THERE IS ANY SMT 4 NEW SURFACED MOUNTED INCANDESCENT LIGHT. DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE ; 00AMP-3P, 120/240V FUSED SERVICE DISCONNECT SWITCH MOUNTED ON WALL. ® TO COLD WATER CONTINUITY TO GROUND OQ1 INSTALL NEW FEEDERS (2#6 & 1#8G) 3/4"CONDUIT FOR CONDENSING UNITS REFER TO PANEL "A" SCHEDULE E-1 O 2'x4' RECESSED FLUORESCENT STATIC TROFFER, 120VAC, WITH 2 LAMPS MKS (LITHONIA CAT # 2SPG-232-120 OR EQUAL) iNO DATE ISSUE FOR CIRCUIT NUMBERS AND C/BREAKER SIZE 22 INSTALL NEW FEEDERS (2#12 & 1# 12G) 1/2" CONDUIT FOR AC UNITS. REFER TO PANEL "A" SCHEDULE O EXISTING PANELBOARD 100A, 30, 4W IN NEW LOCATION 1 0303.00 CLIENT REVIEW/ZONING CIRCUIT NUMBERS AND C/BREAKERS SIZE O7 NEW EXHAUST FAN. 2 04.21.00 ZONING 3 05.31.00 ZONING REVISION 23 INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR CONVENIENCE RECEPTACLES REFER TO PANEL "A" SCHEDULE O8 EXISTING LIGHTING FIXTURES INSTALLED IN NEW LOCATION 4 06 1900 ZONING REVISION E-1 FOR CIRCUIT NIMBERS AND C/ BREAKER SIZE. 5 06 23 00 RF REVISION OEXISTING LIGHTING FIXTURES TO REMAIN IN THE SAME LOCATION 6 06 27 00 ZONING REVISION <9> INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR EXHAUST FAN, REFER TO THE EXHAUST 0711 00 OWNER REVISION FAN CONTROL DIAGRAM ON PAGE E-4. <3> NEW LIGHTING SWITCH 20A-1P 8 101900 CONSTRUCTION/REVISION O25 1 1 ESTABLISH NEW WIRING AND HOME RUN TO EXISTING RELOCATED PANELBOARD 9 11 0700 CONSTRUCTION/REVISION INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR HYDROGEN DETECTOR. O 26 INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR QUAD RECEPTACLE o�,,p0 RfGj�l <9> EXISTING TELCO DEMARC CABINET. 14 c,���s� ••••• cy• 0�. .•F,SH D,••• F� S 28 NEW TELCO CABINET BY OTHERS. ----�_----$----�_---- (TYP) � • '/ 2�• 29 INSTALL NEW WIRING (2#12 & 1#12G) 1/2" CONDUIT FOR SMOKE DETECTOR Off, •••���o •� c�, ONAL ECG\ --- EF-1 L m All drawings and written material contained herein may not be duplicated used or disclosed without the written consent of the architect 3 6 I 10 13 ® - 15 7—— G N 27 16 EF-1 TO EXIST A 12 1 1 I WEST VAI L 28 11 PANELED 1 RE PT o M s To 7 I 6 _ I i I 11 30 M i I 2077 N. FRONTAGE RD. O � A-1,3 N m 31 5 a 22 ,l A-26 N m CU-1 6 6 _ 9 4 TO 24 V DC VAIL, COLORADO 81657 PCII 24 CU 2 RECTIFIER _J — 8 C T 4 ® I 2 H �— 60A-2P, I E— —L —�0� E 240V I Q 19 CAB o q-28 60A-2P, 240V I I I I 8 2 I 21 A-6,8 32 GF 18 25 N " _ 9 I 1 1 17 ; N (TYP, of 3) 20 15 U fi METER & 3 29 'N 21 A-5,7 3 ROOF—TOP ANTENNAS 8c ITRVIrF 432-31 O ENTER 31 P -, uj L_ o o EQUIPMENT ROOM SHEET TITLE M g U 3 Ckf 9 (TYP of 3) I I (TYP ) A-21 M a M �N Q 5 I (TYP 7� (TYP ) 11 POWER, LIGHTING, AND L� 9 A-2,4 Q I 1 GROUNDING PARTIAL —22 8 I 9 PLANS AND NOTES 10 (TYP of 3) 2 ��-- ------ TELCO (TYP 70F 5) 23 (TYP) 4 NUMBER A-24 26 BD. 31 32 11 T 0 S 7, / ALARM 10 1 POWER PLAN n LIGHTING PLAN GROUNDING PLAN a SCALE 3/16" = 1'-0" n SCALE 3/16" = 1'-0" SCALE 3/16" = 1'-0" 24445-7DE-2056—E03-9 1 ` 1 F� now AT&T FEEDER SCHEDULE BUILDING ZCD2 [( 4# 3/0:1#1/0=2" C] Q SERVICE DISCONNECT SWITCH AT&T Wireless Services UTILITY CO METER 400A 30, [4# 3/0 & 120/208V, NEMA 3R 400A-3P, SN, 120/24OV, SUITE C-1 NEMA 3R 1001 16TH. STREET Q (3 # 3/0 & 1# 2G) 2" C 8 DENVER, COLORADO 80265-0003 ® (1 # 1/0 G) 3/4" C - - -- - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - -- - - - - - - - -- - - - - - - - - -- - - - - - - - - - - -- - - - - - - - - - - - - - - MANUAL TRANSFER SWITCH C.T. CABINET 400A, 20OA-2P, SN, 120/240V 120/208V NEMA 3R NEMA 1 (FUTURE) <> AT&T EQUIPMENT ROOM to• N 2 400A �.------ 3 3P 3 ' 400AF i 1 2 [Q}-o CT'S I I SN I I I > I I EXISTING UTILITY CO PAD MOUNTED I I � ` O TRANSFORMER 30OKVA, I , , I I Architects — Engineers, P C 1 30, SEC.. 208/120V 12250 East Iliff Avenue, Suite 302 SN ` 200A I 200A I Aurora Colorado 80014-1253 MOBILE GENERATOR RECEPTACLE I __ 2P I I �� 2P I 303 750.6999 FAX 303 750.0236 20CA, 3P, 4W, 120/24OV, MALE O I I I I � � Email- kdcdenver @kdcarchitects com _ NEMA 3R (FUTURE) I I I I Website. www.kdcarchitects.com UTILITY CO ,�� --I-----------------------------I --� L----J PRIMARY LINE O � 2 � 4 4 AT&T POWER PANEL "A" AT&T POWER PANEL "B" AT&T WIRELESS SERVICES (SEE 1 N, 3W 200A, 10, UT • 3 (SEE PANEL SCHEDULE) NEMA 1 (FUTURE) O2 2101020 003 MOBILE GENERATOR RECEPTACLE MANUAL TRANSFER SWITCH ` • 266A, 3P, 4W,120/240V, MALE 200A-2P, SN, 120/240V FOR NEMA 3R NEMA 1 ROOM, C MKS NO DATE ISSUE ' 1 03 03 00 CLIENT REVIEW/ZONING 2 0421 00 ZONING 3 0531 00 ZONING REVISION 4 06 1900 ZONING REVISION 5 0623.00 RF REVISION 6 06 27 00 ZONING REVISION 07.11 00 OWNER REVISION 3 8 10 1900 CONSTRUCTION/REVISION ONE-LINE DIAGRAM PANEL A 9 1107.00 CONSTRUCTION/REVISION SCALE NONE 1! 8 4PAL R SUPPLY, 120/208V, 10, 3W BRACINGt 42000A RMS SYM ENCLOSURE, NEMA Ip O RE � MAINS. 0 MOUNTING, SURFACE •.•••••••.• F H D •. PANEL BUSt 225A V • LOAD BRANCH C/BREAKER CKT LOAD (KVA) CKT BRANCH C/BREAKER LOAD •�� • • DESCRIPTION POLES TRIP FRAME # 0 A 1 0 B # FRAME TRIP POLES DESCRIPTION 253 I 562 •i (I/7/Da •• •• AHU-1 2 15A IOOA 3 562- -562 2 100A 15A 2 AHU-2 �C�s+ •••••••• �� 562 4 s�DNAI 5 3338 3338 \' NOTE. GENERAL NOTES= CU-1 2 60A 100A 7 -- 3338 6 IOOA 60A 2 CU-2 �- POWER AND TELCO TO BE F 3338 8 m All drawings and written material contained COORDINATED WITH OWNER, 9 1440 herein may not be duplicated used or disclosed AT&T PROJECT MANAGER AND 1 ALL NEW WIRING SHALL BE COPPER WITH RECTIFIER #1 2 30A 100A 1440 -- d12 IOOA 30A 2 RECTIFIER #4 without the written consent of the architect INSULATION RATED 600V, 90-C, UTILITY COMPANIES 11 14400 2 TOTAL LENGTH OF FEEDER�3 SHALL NOT 13 1440 EXCEED 25 FT RECTIFIER #2 2 30A IOOA IS 1440- - 14 IOOA 30A 2 RECTIFIER #5 A ' O 1440 16 KEY NOTES 17 1440 -- RECTIFIER #3 2 30A IOOA 19 -- 1440 1B IOOA 30A 2 RECTIFIER #6 WEST VAI L 1440 20 <D> EXISTING UTILITY CO PAD MOUNTED TRANSFORMER © ENVIRONMENTAL CONTROL PANEL I 20A IOOA 21 200 -- RECEPTACLES 300 KVA, 30, SEC.. 208/120V 900 _ 22 100A 20A 1 2077 N. FRONTAGE RD. 1 20A IOOA 23 --- 640 LIGHTING QUAD RECEPTACLE <2> FUTURE EQUIPMENT AND WIRING TO BE INSTALLED 360 z4 1DDA 2oA VAIL COLORADO 81657 © SMOKE DETECTOR 1 20A lOOA 25 12 - EXHAUST FAN UPON EXPANISION NEEDS 1150 - 26 IOOA 20a 1 SPACE 1 20A IOOA 27 --- 60 28 IOOA 20A 1 HYDROGEN DETECTOR �L ESTABLISH SERVICE GROUNDING CONDUCTS TO BE 3 CONNECTED TO EXTERIOR GROUND RING AND COLD SPACE I 20A IOOA 29 --- 30 1 SPACE y WATER SERVICE PIPE SPACE -- IOOA 31 - SPACE � 32 1 LOAD STUDY: SPACE 1 20A lOOA 33 -- 34 1 SPACE EXISTING PEAK DEMAND LOAD IN THE BUILDING, FOR SPACE 1 zoA IOOA 3s 36 1 SPACE THE LAST 12 MONTHS, IS 45 6 KVA SPACE I 20A IOOA 37 --- 38 1 SPACE SPACE I 20A IOOA 39 --- ROOF-TOP ANTENNAS & MAXIMUM NEW DEMAND LOAD TO BE ADDED BY AT&T 1 zoA IDOA 41 40 IODA 20A 3 SURGE ARRESTER p EQUIPMENT ROOM EQUIPMENT IS SPACE --- 42 400A x 0 8 x 208V = 66 6 KVA TOTAL CONNECTED LOAD PER PHASE (KVA) 17540 17500 PANEL DEMAND LOAD CKV0 35040 SO, TOTAL NEW DEMAND LOAD ON THE UTILITY CO TRANSFORMER PANEL TOTAL CONNECTED LOAD (KVA), 35040 PANEL DEMAND LOAD (A), 146 IS 45 6 KVA + 66.6 KVA = 112 2 KVA SHEET TITLE EXISTING UTILITY CO TRANSFORMER IS 300 KVA. PANEL DEMAND LOAD CALCULATIONS, LOAD CONNECTED KVA DEMAND FACTOR DEMAND KVA REMARKS SUMMARY- UTUILITY CO TRANSFORMER CAPACITY IS ADEQUATE TO LIGHTING 640 100 0 RECEPTACLES 1260 100 % 12 CARRY ADDITIONAL AT&T EQUIPMENT LOAD 1260 1 ❑L - INDICATES C/BREAKER LOCKING DEVICE ONE-DIAGRAM, PANEL MOTORS 15768 100 /. 15768 2. INSTALL ISOLATED GROUND BUS KIT SCHEDULE AND NOTES OTHER 17312 100 X 17372 ■ (�) PANELBOARD SCHEDULE SCALE NONE E � 4 24445-7 D E-2056—E04-9 • ALARM NOTES 1 ALL ALARM WIRING SHALL BE #22 AWG AT&T 6"x 6"x 4" NEMA 1 ENCLOSURE WITH SOLID WIRE (RED/BLACK) INSULATED, DOOR MOUNTING PANEL FOR RELAYS, NON—SHIELDED CABLE TYPE HOFFMAN #A-6N64/A-6N6P 2 ALARM CABLING FROM RIGHT—HAND SIDE OF M66-100 BLOCKS TO INTERFACE EQUIPMENT WILL BE PROVIDED AND INSTALLED BY USER. — -- AT&T Wireless Services --- 3 NORMALLY OPEN (N/0) ALARMS WILL 1 SUITE C-1 CLOSE ON ALARMEED C//ON))DITION � 2 1001 VER6T COLORADO 80265-0003 (2 #22) 1/2"C OPEN AON ALARMED (CONDITOIN O O 0 O TO EXTERNAL ALARM ---3– PANEL PINS 27 & 28 HIGH TEMPERATURE 0 4 ALARM - - - - ---5- ■ THE HIGH TEMPERATURE I – O O O O 1 ALARM CONTACTS ARE I 6 WIRED NORMALLY CLOSED. N C 1 RELAY–SPDT RELAY–SPDT 1 A TEMPERATURE INCREASE I B / 7 ■ , 120 VAC COIL 120 VAC COIL (RISE) TO 85-F WILL I I ------- 120 120 RELAYS SHALL BE SEE DRAWING CONTACTS– I I I O IW 0 8 OMRON RELAYS #MJIPUAAC120 - - - -- (2)--- – W/ SOCKET RED TO PINS ----_g– ' - - - - - - LOW TEMPERATURE 11 & 12 10 ALARM I_ _ _ — — BLK HI TEMP RED 2) 11- H1 NEUTRAL H2 ALARMOCONTACTSAAREE I I N/C ALARM BLK �-- 12_ WIRED NORMALLY CLOSED I I 1 O 113 RED TO PINS RED (Z) 13 (FALL)A TEMPERATURE DECREASE I I 13 & 14 LO TEMP 0 ENTHOE CONTACTS I BLK ALARM N,,aLK 14 POWER FAILURE RELAY SEE DRAWING M-1. — — — — — RED 1 SCALE. NONE RED 15 PINS DOOR ALARM -- 15- N/C EQUIPMENT ROOM BLK 15 & 16 (EQUIPMENT BLK � 16 DOOR ALARM THE CONTACTS FOR THE MAGNETIC 17 DOOR ALARM ARE WIRED NORMALLY -- 8 K C CLOSED. WHEN DOOR IS CLOSED, CONTACTS WILL CLOSE WHEN DOOR Architects – Engineers, PC _______ IS OPENED, CONTACTS WILL OPEN (2) 19 VERIFY WIRING OF DOOR ----- 12250 East Iliff Avenue, Suite 302 ALARMS W/ JOEL HUMKE (303) 349-7957 (2) 20 Aurora, Colorado 80014-1253 (2#12&1#12G)1/2 C --------- 303.750 6999 FAX 303 750 0236 21 Email kdcdenverQkdcarchitects com TO S (TECH ON SITE) SWITCH �-- 22 Website www kdcarchitects com H 22 H TO PANEL "A" 0 23 N I N (SEE PNL "A" SCHEDULE 0 24 AT&T WIRELESS SERVICES G ON DWG E-1) __ _ PROJECT NUMBER G 25_ (2#14)1/2"C POWER FAILURE ALARM (2) 26 2101020003 M D A 240 VAC RELAY IS INSTALLED ACROSS RED ---- 27_ 11111973 f– DAMPER ALL PHASES OF INCOMING COMMERCIAL RED TO PINS AC r IL DP POWER UPON POWER LOSS, A SET 27 & 26 HYDROGEN GAS DETECTOR OF NORMALLY CLOSED CONTACTS WILL E/C BLK COPOWER IAL BLK -- 28– , BY MACURCO, INC CAT# HD-21-1–BR OPEN, GIVING AN ALARM 29 — — ----- MKS 30 INO DATE ISSUE 1 COMMON R I (2#12&1#12G)1/2"C –_ 44– -- 1 0303.00 CLIENT REVIEW/ZONING TO PIN 45 (Z 45 COMMON 2 0421 00 ZONING FUSE FAILURE OL I R TO PIN 46 0 46 FUSE FAILURE 3 05.31 00 ZONING REVISION H UNDER VOLTAGE ------- 4 06 1900 ZONING REVISION Dl_ i I TO PIN 47 +24 VDC 0 47 UNDER VOLTAGE I _______ 5 062300 RF REVISION RECTIFIER FAILURE RECTIFIER 6 0627.00 ZONING REVISION TO PIN 48 ALARMS 48 RECTIFIER FAILURE TO PANEL "A" MAINS FAILURE 0711 00 OWNER REVISION } M N I– � (SEE PNL. "A" SCHEDULE . TO PIN 49 49---------MAINS FAILURE 8 10 19 00 CONSTRUCTION/REVISION ON DWG E-1) �u OVER VOLTAGE TO PIN 50 50 OVER VOLTAGE 9 11 07.00 CONSTRUCTION/REVISION G +24 VDC RECTIFIER ALARMS M1-50 BLOCK #1 �p0 REGj EXHAUST FAN — — ALL +24 VDC RECTIFIER ALARM CONTACTS ;.•0H.•.•SJ1 ARE NORMALLY OPEN A FAILURE WILL • CLOSE THE CONTACTS FOR THE RESPECTIVE = •�: 1J SWITCH WITH THERMAL OVERLOAD RELAY WITH 120VAC COIL, ALARM THESE ALARMS AND AN 8–PAIR 15253 COMMUNICATION CABLE WILL BE PROVIDED 1 N 0. CONTACT RATED 20A, AND INSTALLED BY LUCENT °•:51 COMMON �!'7/oCv , 120VAC (INDUCTIVE LOAD) �F 0660.•.•..• Q •. cv ENCLOSURE NEMA 12 52 MAINS FAILURE f4NAL 53 FUSE FAILURE 54 OVER VOLTAGE m All drawings and written material contained EXHAUST FAN CONTROL DIAGRAM herein may not be duplicated used or disclosed 2 SCALE: NONE RED TO PINS SMOKE RED �_– 55– without the written consent o1` the architect SMOKE DETECTOR ALARM 55 & 56 DETECTOR -- N/C BLK ALARM BLK (2)-- 56-- 56 DC DISTRIBUTION FAIL ALARM (2) 57 A SET OF NORMALLY CLOSED CONTACTS WILL RED TO PINS (2) 58 WEST VAI L OPEN DURING AN ALARMED CONDITION, 59 & 60 ------ INDICATING A LOSS OF DC BATTERY N/C BLK DC DISTRIBUTION RED (Z 59 DISTRIBUTION POWER TO THE RECTIFIERS. FAIL ALARM BLK 60 2077 N. FRONTAGE RD. WILL BE PROVIDED AND INSTALLED BY LUCENT 0 61 VAIL, COLORADO 81657 -- SURGE ARRESTOR ALARM RED 0–_ 62 62 RED TO PINS SURGE (Z 63 A SET OF NORMALLY CLOSED CONTACTS - =/CBLK 63 & 64 ARRESTOR -----WILL OPEN DURING ALARMED CONDITION, BLK INDICATING A FAILURE OF SURGE ARRESTOR. (EEMDIAGRAM) -- 0 65 66 67_ ROOF-TOP ANTENNAS & 68_ EQUIPMENT ROOM SPARES RED TO PINS RED 0 69 THESE ALARM POSITIONS ARE NOT USED AND TN/ BLK 69 & 70 SPARE BLK – 70 ARE PRESERVED FOR SPARES. THESE ARE _ DETERMINED BY THE CUSTOMER AND THE RED – 71 SHEET TITLE OPTIONS WHICH ARE REQUIRED ALL ALARMS RED TO PINS SPARE ----- SHOULD BE WIRED NORMALLY CLOSED 71 & 72 BLK 72 INDICATING AN A ALARM ECONDITIONNTACTS, =/CBLK ----- 0 73 DETAILS AND PINS 73-100 0 74 DIAGRAMS ARE NOT 98 UTILIZED --------- 99 100 • M66-100 BLOCK #2 3 !T��nALA LARM PANE L E � 5 24445-7DE-2056–EO5-9 M 1 I 1 TO WAVE GUIDE LOCATED AT CHASE. ROUTE • TO ANTENNA GROUND BUS —CONDUCTOR ATTACHED TO COMMUNICATIONS SEE DETAIL B/E-4 CABLE SUPPORT IF H 4 s d RADIO EQUIPMENT GROUND BUS II d 0 a a n 6 o ea as Qa a 1 II 1/ . . .. .•1 fl O O O O WALL- MOUNTED SOLID . 0 Et SECURE TO WALL WITH APPROVED ® ® INSULATORS PLAN VIEW 000 AT&T 0 0 0 0 AT&T Wireless Services ONE HOLE CRIMP CADWELD OR SUITE C-1 LUG TO EXISTING CABLE TO PIPE CONNECTOR 1001 16TH STREET SCREW BURNDY TYPE GAR DENVER, COLORADO 80265-0003 —WTH COPPER GREEN INSULATION `INE3/4R C 0 0 0 0 0 SPACING AS SHOWN (�'P FOR 2 PLACES) 1/4" x4" x12" SOLID COPPER ON DWG. 0 ® MOUNTED AT ANTENNA LOCATION O _ #2 TO HALO GROUND 0 0 0 0 O SEE PLAN 3/E-2 WAVE GUIDE AT TENANT SPACE I• •I 2 AWG BCW • • • e #2 COPPER GROUND CONDUCTOR T 000 0000 WITH GREEN INSULATION IN 3/4" #6 AWG STRD CU I -� MASTER GROUND BAR —CONDUIT TO RADIO EQUIPMENT -- GROUND BUSBAR 4" x4" x6" SOLID COPPEIj TWO HOLE CRIMP LUG WALL- � � • I O SECUREM OU WALDL WITH APPROVED 3/8" BOLT, NUT & O 0 RADIO EQUIP GROUND BUS ® ® INSULATORS SEE E/E-4 FOR WASHER O INFORMATION O O E LEVATI O N #2 AWG. SOLID 1 2" PVC PENETRATE WALL WALL/ROOF FEED THRU ASSEMBLY E M N 1 1 3/0 COPPER INSULATED GROUND CONDUCTOR CU BARE TINNED SEAL WITH CALKING AS REQD ANDREW 204673-1, COAX BOOT IN 1 SIZE AS READ PER COAX SIZE GRS TO COLD WATER PIPING TO MASTER GROUND BAR (TYP 1 PER COAX ENTRY) ANTENNA GROUNDING AT INTERNAL GROUNDING DETAIL ANTENNA GROUND BUS WAVE GUIDE ENTRY PLATE GROUNDING D SCREENED WALL (ONE SECTOR SHOWN) A B C KDC Architects - Engineers, P.0 SCALE N T S SCALE N T S SCALE N T S 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750.6999 FAX 303.750.0236 "N" SECTION Email kdcdenver @kdcarchitects.com "A" SECTION NON-IGZ Website www.kdcarchitects.com (SURGE EQUIPMENT) ARRESTER) LEGEND "P" SECTION "I" SECTION IGZ ISOLATED GROUND ZONE AT&T WIRELESS SERVICES i i MDF MAIN DISTRIBUTION FRAME TO OTHER SURGING (SURGE i , IGZ EQUIPMENT MGB MASTER GROUND BAR PROJECT GROUND BARS PRODUCERS) i i CONNECTED VIA MGN MULTI-GROUND NEUTRAL IGB STAND-OFF 2101020 003 INSULATOR I • i DP 0 0 ® 0 40P i i i ' MKS � � I i NOTES i DATE ISSUE O O O O LQ LO 0 O 1. ALL "A" AND "I" SECTION WIRES ARE STANDARD. eo GREEN INSULATED #2AWG 1 03.03.00 CLIENT REVIEW/ZONING i " 2 04.2100 ZONING 2. N SECTION. USE BARE #2 AWG FOR IGR (HALO) WIRE. TO MDF PROTECTOR 3 05 31 00 ZONING REVISION GROUND BAR O O i 3 O i 0 0 i 3. "P" SECTION WIRES ARE GREEN INSULATED #6 AWG (MIN ) 4 06 1900 ZONING REVISION 4. USE LUGS APPROPRIATE TO WIRE SIZE AND TYPE. 2 HOLE 5 06.2300 RF REVISION TYPE REQUIRED WHERE SHOWN, PREFERRED ELSEWHERE 6 0627.00 ZONING REVISION 5 ROUTE TO 1" OR LARGER C W PIPE 07 11 00 OWNER REVISION t 8 10 1900 CONSTRUCTION/REVISION LTO BUILDING STEEL 9 11 0700 CONSTRUCTION/REVISION OR REBAR m [TO IGZ-2 �P�O RED/S�, TO CELL SITE EQUIPMENT O .••"•••. F ( TO COLD WATER PIPE �, ; d • NOTE 5 •' TO POWER SUPPLY TO IGZ-1 •`" 3 's TO MGN "AC GREEN WIRE" EXOTHERMIC WELD j7�b0 (AT ENTRY PANEL) TO BUILDING GROUND Fs's/'••••'E�G��� , ONA� MASTER GROUND BAR CONNECTIONS NOT USED NOT USED m All drawings and written material contained E F G herein may not be duplicated used or disclosed without the written consent of the architect. SCALE: N.T,S, SCALE N TS SCALE N T S 2 AT&T PANEL "A" WEST VAIL SURGE ARRESTER KEY NOTES __ _ _ _ _ _ _ _ _ SURGE ARRESTER GENERAL NOTES MAIN C/B 2077 N. FRONTAGE RD. OlSURGE ARRESTER JOSLYN ELECTRONIC 20OA-2P # 1455-85, 120/208V-30 (OR APPROVED EQUAL) 1 SURGE ARRESTER SHALL BE CONNECTED TO THE AIL, COLORADO 81657 L1 I I I I MAIN C/BREAKER OF PANEL "A" (0A) I L1 I I L1 2 GROUND BUS IN SURGE ARRESTER IS UTILIZED -� �2 MANUAL TRANSFER SWITCH 0- ONLY AS AN EQUIPMENT CASE GROUND. O3 #22 AWG SOLID WIRE INSULATED, I I 3. WIRING FROM THE SURGE ARRESTOR TO THE NON-SHIELDED CABLE, 1/2 C TO EXTERNAL I I MANUAL TRANSFER SWITCH SHALL BE #4 AWG, ALARM PANEL PINS 63 & 64. L2 I THW (MINIMUM) OR AS SPECIFIED BY THE SURGE O4 (4 #3/0 CU + 1 #4 CU GND) TO SERVICE (OB) I L2 I I L2 ARRESTER MANUFACTURER DISCONNECT 0— 4 ALL CONDUCTORS SHALL BE FANNED OUT ROOF— TOP ANTENNAS & 2 EMT CONDUIT SWITCH I I I SMOOTHLY NO RIGHT ANGLE BENDS ARE (D 208/120V 4 #4 AWG THW (MINIMUM) INSULATED COPPER WIRE PERMITTED, CONNECT ALL LEADS A,B,N,G, EQUIPMENT ROOM TOGETHER SO THAT THEY WILL BE IN CLOSE (SEE NOTE #3) CONNECT CONDUCTORS TO LOAD SN SN PROXIMITY TO EACH OTHER. LENGTH SHALL SIDE STUDS WITH BLACKBURN #GTL-516 OR EQUAL LUGS N N BE AS SHORT AS POSSIBLE BUT NO LONGER THAN 8 FEET. 6 4 # 6 ) 3(4" C I I I SEE NOTE #3J CONNECT CONDUCTORS TO LOAD 5 SHOULD ADDITIONAL INFORMATION BE REQUIRED, !ISHEET TITLE CONTACT JOSLYN ELECTRONIC SYSTEMS DIVISION, SIDE STUDS WITH BLACKBURN #GTL-516 OR EQUAL LUGS GND I GND GND I I GND SANTA BARBERA RESEARCH PARK, BOX 817, GOLETA, CALIFORNIA 93017 (805) 968- 3551 - - - - - - - - - - DIAGRAMS 4 DETAILS AND 6 GND N L1 L2 ISHEET NUMBER N G 3 1 10 TO PORTABLE 2 GENERATOR RECEPTACLE 3 SURGE ARRESTER DIAGRAM NOT USED H I SCALE N T S SCALE N T S 24445-7DE-2056-E06-9 1 s t FINISHED GRADE AT&T o I o 0 N z TWO HOLE CRIMP AT&T Wireless Services s 4 0 LUG TO EXISTING SUITE C-1 WARNING TAPE SCREW 1001 16TH. STREET--N ELECTRICAL AND ALARM CONDUIT ° ° o C) DENVER, COLORADO 80265-0003 (PLACE WARNING TAPE 2 BELOW FINISHED I 0000 o ° o ° o PRIMARY GROUND BAR DETAIL CRIMP TO ° ° ° o REFER TO 4/E-5 GRADE ONLY WITH FIBER OPTIC CONDUIT) ° O O O O O 0 000 o ° o #2 AWG CABLE —1/4" x4" x12" SOLID COPPER ° o ° o ° MOUNTED AT ANTENNA LOCATION ° o GROUND ELECTRODE WAVEGUIDE HATCH O O O O �-- #6 AWG STRD CU #2 COPPER GROUND CONDUCTOR FUEL LINES TWO HOLE CRIMP LUG ° ° WITH GREEN INSULATION IN 3/4" NOTES. 3/8" BOLT, NUT & WSHR .,,--CONDUIT TO RADIO EQUIPMENT o GROUND BUSBAR 1) COPPER GROUND BAR OR APPROVED EQUAL, EXTERNAL GRD BAR MTD. 1/4" x 4" X 24". HOLE CENTERS TO MATCH NEMA DOUBLE LUG CONFIGURATION 4" (SCHEDULE 80 PVC - REGEN FIBER #2 AWG SOLID CU. HATCH PLATE 2 SPACERS AS REQUIRED OPTIC CONDUIT) BARE TINNED. TO EXTERNAL 3 5/8" LOCKWASHERS 4) WALL MOUNTING BRACKET RING GRID RING 5) 5/8" -11 x 1" H.H.C.S. BOLTS 6) GROUND BAR TO BE SUPPLIED WITH EQUIP SHELTER TYPICAL GROUND BAR STANDARD BURIAL DEPTHS WAVEGUIDE HATCH GROUND ANTENNA GROUND BUS K C A C < C D Architects — Engineers, P.C. SCALE. N T S SCALE N T.S SCALE N T S SCALE N T S 12250 East Iliff Avenue, Suite 302 Aurora, Colorado 80014-1253 303.750 6999 FAX 303.750.0236 Email. kdcdenver @kdcarchitects com CABLE GROUND KIT TO ANTENNA BGRO 4ND BUS. Website. www.kdcorchitects.com FROM ANTENNA W RE (GROUNDED TO COPPER GROUND BARD I RX I STANDARD ANDREW AT&T WIRELESS SERVICES GROUND KIT (STANDARD ANDREW GROUNDING KIT) ANTENNA JUMPER 1/2" (TYP) L CABLE O O O O 1/4" x4" x12" SOLID COPPER r----- WALL— MOUNTED AT +84" :PROJECT I TO ANTENNA T X ® INSULATORS ANTENNA COAX CABLE _ _ _ _ I I ,101020 003■ ANTENNA __ CABLE O O O O DP 3 3 4" 6" --_T NO SHARP BENDS V1/2" DIA. AX. 12" APPROX. L____J #2 COPPER GROUND CONNECTOR MKS INSIDE WALL WITH GREEN INSULATION IN 3/4" C OF BUILDING COLD CONNECTOR SHRINK #6 AWG LADDER WEATHERPROOFING KIT (TYP) STRANDED COPPER 1 0303.00 CLIENT REVIEW/ZONING AT ANTENNA GPS CABLE END WIRE 2 042100 ZONING #2 TO HALO GROUND I SEE PLAN 3/E-2 3 05.31 00 ZONING REVISION CABLE GROUND KIT DOUBLE HOLE 4 06 1900 ZONING REVISION #6 AWG STRANDED COPPER GROUND CONNECTORS (TYP) 5 06.2300 RF REVISION WIRE (GROUNDED TO GROUND BAR) 6 06. 00 ZONING REVISION (STANDARD ANDREW GROUNDING KIT) -� _(CONTINUOUS) MASTER GROUND BAR 07.11 t GROUNDING BAR TO TRANSITION 8 110 1900 CONS RUCTIO REVISION REVISION ON T 0 MONOPOLE GRD ROD AT BASE OF O WALL— MOUNTED SOLID COPPER 9 " 9 11 07 00 CONSTRUCTION/REVISION TO ANTENNA ON ISOLATERS MONOPOLE SECURE TO WALL WITH APPROVED ANTENNA — INSULATORS. SEE E/E-4 FOR -� COAX CABLE 211 6„ ® ® INFORMATION �4 RE�j p�� '�ZH D'•.�T 12" APPROX. O O • o c� • mac' - 3/0 115258 "COPPER INSULATED GROUND CONDUCTOR 53 AT ANTENNA CABLE END IN 1 GRS TO COLD WATER PIPING �•: r� NOTE. DO NOT INSTALL CABLE GROUND KIT AT A BEND o,��SJ�l7joe�••.\�c�,`� s�4NAL ECG TYPICAL CONNECTION AT ANTENNA TYPICAL ANTENNA GROUND TO INTERNAL GROUNDING DETAIL NOT USED Q All drawings and written material contained E F G H herein may not be duplicated used or disclosed CABLE END SCALE N T S GROUND BAR (ANTENNA LEVEL SCALE N T S SCALE NT.S SCALE NTS without the written consent o the architect WEST VAIL 2077 N. FRONTAGE RD. VAIL, COLORADO 81657 ROOF-TOP ANTENNAS & EQUIPMENT ROOM SHEET TITLE. GROUNDING DETAILS SHEET C NUMBER NOT USED K NOT USED L NOT USED M NOT USED SCALE N T S SCALE N T S SCALE N T S SCALE N T S , 24445-7DE-2056—EO7-9