Loading...
HomeMy WebLinkAboutPRJ07-0352 B07-0248.PDF , --- �... �.- Gwathmey ���� � '��7 � ���X Pratt � ��3�3���'I�T I Ol�lS s�nuitZ �,� �1�GHOR �OLT ��G�I T�GTU iZ�L A�°h�te°ts,p G � _ 1000 S Frontage Rd West �81� ��OY� Vail,Colorado 81657 Tel (970)476-1147 �D �i��,� Di�I N � Fax (97C)47 �DJ ,�DJ�G�1�lT _ _ _ ��F �B011� �I N I SH FLOOR �LUM �LUMINUM - � �LT A�LT�iZN�T� �2.1 PROP05�D PL?� ,4P �GG�55 P,4N�L �2.2 PROPOS�D iZE�LEGT�D G�I L I NG PL�N, �. �NGL� B.O. �OTTOM O� DOOiz SGH�DUL� � D�T�ILS � GLG G�I L I 1�1G G I G,�ST I RON � GJ GONTiZOL JOINT � � GENT�R LINE GOI7� GOM�� I��1G� „� ; GLR GOLOR � GMU GONGi��T� M�50NiZY UNIT GI I �GRE55 �Lr4N5 �OR �-3�LLiZOOM �ND ' GO GL��NOUT S�LON GOMBINA�TIONS O � GOL GOLUMN � � GONG GONGi��T� , GONT GONTI�IUOUS � � DO DOUBL� 1N�LL OY�NS DW DISITY�SHER � �Q �G2U�L O � O �D �LOOR Di�I N O ---� �DN �OUND�TION IN �INISH � I �T��I O� ��5 I G� O � � `> �LiZ �LOOiZ " � �.O.W. ��G� O� Y�I,�LL(STUD,�TG) ,� � � �TG �OOTING 1vl'�Gf���l I G�� SYST�MS —� � GYP GYPSUM W�LL BO�i�D � , � , GL GL�SS/GL�Z I NG � O LOW M�T�L MI M�G+��NIG�L DEMOLITION � HM H L �tT HEIGHT M2 N�W WORK PL�N INSUL INSUL�TION M3 SYM�OLS �S�-3RE�lI�TIONS D�T�ILS iGIT 1GITGH�1� GO�� I �I�O�M�T I O�l P011�1T �ND SGH�DUL� Li� LOW Q MO M�SON�Y OP�N I NG MTL MET�L ZONING DISTRIGT LHMU-I ���GTiZ I G�L. �L�YO T O � N�G �I�G�SS�RY OGGUP�4NGY TYPES ,4-2 ,455EMBLY 11 �� V N I G NOT I N GONTR�GT GONSTRUGTI ON TYPE. I IA (OLD TYP� I I-Fi� �I.I EL�GTRIG�L D�MOLITIO NO NUMBER NTS NOT TO SG�L� OGGUPA�NGY S�PA�R�TION REQUIREMENTS �2.I �LGTi�IG�L LIGHTING OH OPi�05IT� H�ND �PER 2003 IBG TABLE 30232) � R-I TO A-2 2� �31 �L�GTRIG,4L POW�R - � �4.1 �L�GTRIG�L SYMBOL L�G�ND � J OPG OP�N I NG �2 To s2 2+�+� PL !�M PL�STIG L�MIN�T� � � > OGGUP�NGY L0,4D5 ,4BBi��Y1,4TION5 �4ND G�N��L NOT�S �' o � ~ PL�G PLUMB I NG PREFUNGTION � 5 SQ FT PER PERSON 600 PERSONS � O ' GOLOi?1�D0 B,4LLROOM � 7 S� FT PER PERSON 680 PERSONS �42 LIG�+TING GONTizOL SGH�M�TIG P�ND � '� PL i�ROPE�TY L I NE z � � w PLWD PLYWOOD GONSTRUGTION ,455EMBL1�5 SGH�DUL�S � cr� o , � ��c��� FLOOR GEILING l.� DESIGN Jq48 2HR ~ RD ROO� DR�IN FLOOR/GEILING AT GP�RAGE UL DESIGN Ja48 2HR + ���L R��L�GT�D 5�E SHEET GI I FOR EGRESS REQUIREMENTS AND GOMPLI?�NGE R�Q R�QUIfi��D p Copyr g Gwathmey/PratF/Schu liz Archltects P C ��Y �����5� � I ��GTO�Y .. All Rlghts Reserve This document,and the ideas RGH ROUGH and designs Incorpora e herein as an instrument oT RO ROUGH OP�NII�G py�x��'S R�PR�SENT�TII�E P�►i�TITION GONSULT�NTS \ / G I professlonal service Is e RM ROOM A�RGHITEGTURf�L RESOURGE GONSULTANTS� ING ?�IR W�hLL TEGHNIG1�4N5 - ROY SPR�DLIN �U�IO Y IJU�l� propertyofGwathmey/Pratt Schultr Architects P C and Is not 51 OI GOLLEGE BOULEVP�RD to be used,In whole or In part,ro� 5��� 5�1���t�-r I-iQ0 38TH STREET, SUITE 10� any oTher pro�ect wlihout the BOULDER� GOLOR�DO 80301 PA�v'MINGTON, NM 87402 written authorization of Edward M Gwatfimey Jr,Henry R Pratt, SI-fT SH��T TEL (303) 443-0330 - P�4X '303) 443-1508 (TEL) 505566361a (Fa� 5055663624 (EM�IL) rspradlfn�airwalltechcom orSldneySchultz SIM SIMIL.�i� py���� �F�� PURG�SING �GE1�lT SOG SL�B ON GR,4D� DI?�MONDROGK HOSPITRLITY GROUP BENJ�4MIN WEST - DI}�NE GUDWORTH, ISHP ba03 ROGKLEDGE DRIYE, SUITE 800 2655 GRESGENT DRIVE, SUITE ,4 DQ�: �U(7 2O �'r SP�G�D SP�G I�I�D BETHESDA, M,4RYL4ND 20817 L,,4F?�YETTE, GOLORA�DO 80026 S��GS SP�G I�I G�T I ONS (TEL) 240 744 I I66 (TE1..) 303 aa6 8104 OR 303 530 3885 xl I 04 � s�Q �� O� STD ST�ND�RD �RGHIT�GT G�1�lE1�L GO1�lTi�GTOR GPSL �4RGHITEGTS, PG J L YIELE �ONSTRUGTION, ING �S�P I�F O� STO� STO�G� 1000 5 �RONTP.GE ROAD W�ST SUITE 102 1000 SOUTH FRONT?�G� ROAD WEST, SUITE 202 VP�IL, GOLOR,4D0 8165�i (470)476-1147 Y�41L, GO 81657 TEL a704763082 F�4 a704763423 EMP.IL BARNOLD�I�IELEGONSTRUGTIONGOM `T'OWB°1 O� �aj� T TiZ��D DEM�RGO�IN DRIOR DES��'P,aUL�DEMARGO ������ � � , T�L T�L�PHON� 601 RIVER BEND ROAD THIG THIGIG/THIGKNESS GRE,4T F,4LL5, VIRGINI�4 22066 (TEL) "103 75a 086�1 - ��__� TYP TY�IG�L STRUGTUi�L �NGIN�EiZ T.O.D. TOP O� D�GiGING JVA� GONSULTING ENGINEERS � F� @�� � 00 T.O.S. TOP O� SL.�B 131a SPRUG� STRE�T BOULDER, GOLOR�4D0 80302 r 0 � � (T�L) (303) 444-IQ51 - FAX(303) �F44-Ia57 UN.O. UNL�SS NOTED OTH�RWIS M�GH�NIG�L �1�lGIN�ER � ?�LYINE ENGINEERING -JOHI� �4 DEL.A�NEY ` �� �.•,�,� 1102 DOUG1�5 ON THE M�LL �` V ���I�5 OMAHP., NEBRASK,4 68102 (TEL) 402346700�i (Fp.� �02346a576 (EMP�II.� delane �alvinecom w/ Y�IITH �L�GTRIG�L �KGI�IEER W/O WITHOUT ,4LVINE ENGIN�ERING — RUSSELL R 5�4GK , 1645 N STREET, sui� B Sheet �lumber J/�G YV�TER GLOS�T LINGOLN, NEBRA5IGA� 68508 . 1/�/D W,45H�fi�/Di�YER (TEL) 402�F7�6161 (F.h� 402.47"19616 (EM�411� rsack�alvinecom WT WEIGHT � . . Gwathmey � Pratt � Schultz .. Architects,p a 1000 S Frontage Rd West Vad,Colorado 81657 � Tel (970)476-1147 � � , . ♦ �.. � . ex�sn�es�s cnorss mgn���,�y � . � � Fcix (970)47�1612 3. ewsnru�ss caa¢s ewsn�esieex c�aoics \ � - � � 72�� �7C REhM.IN ,,� • TO RBMIN =- \ �21, �. �ro ReruiK ;B6" 3 � ro�,IN �36" \ •; " � � �, � � ' — � 3 ��. � � ,,�. — � \ '36" 3 \ �6" � 36'" � � I� � � € � � � �,�� I � ,>;,>, .. I °:,;;. <':>:::: >:::.: _:<:::: ------ � I I ;, I �- �s�----------� I �� i j_� I . � � .�.... I ; I � :::::: I � � - � �:<�: I ' I I `: I I -- � / I � � ,:.�;:<. � ; O O �_ _ - � I � �C' � I — �- m-'-►--- ----------------a--�►----- �� ____J ��________ .'�:::s:`:s:, -..! � �.�.>:r:.>.:< � ---�— —� ��� ; �► � � ► � ��, r �, � , ��� ��`� � � ,:::: I � i �-�----- ---'�--- ---►-----------fi---o------� � i ; ' -=l j ; 'y I I �V I ' i ''".<',:�: o � SftLON I i � � o S�.LON I � �-�------- ----- ---- --- r_--�---, i �,Y� -�=---- i �--.-----� � w�uw�.r ct�s ( � OGGUP�NT LOAD 222 � r -�------�r------- --�----- �a�--�--p � e��v�•,�,Pr _ - >:;. � >:.::.;:.. , ;:..::;::»>::: ::.::.;:. , ::.::.:::> , ::::::;:>:::: ,;;>;;:;;::. , »<>.<,:.;. � I "..' � a�-e-v4•,v� '�, ;;;;;:;;;;: ( � �� �--------►�------� � - .......�... � .\;:;;:::�:: ''°°° REQUIRED �XIT WIDTH 33 I � �- I � � ` : I � --------�i--, I I ----- i_____________ w�urv,r cu � \ �;:•.:;;;;; I rw,.�wr,r a.e ` � � I I � � � O , � 1 a o,w � I ..\ r, � � I � I I �. � a��,�r � • r' i � I i i i � SP�LON 3 �� � ��. ; �� S�LON 3 i ��, ; „ ...M...._.....� 36 ; ; 36 � � , 36 �,, ; 36 I ' � I � � OGGUPAKT L0�4D 135 , ---- l . .�. �` � � � I - 7 � � I I � .� I � - �'. I I � i \ . I � I H2 REQU IR�D �XIT W DT � , . � �w � R.�'.'> /� ?:i'>:v:>: 1 o �---- � � T 5,4L�N 2 i � ,... ,,,,.: • - I ! ���•'�� � � � � '`"�� I � I I OGGUP?�A1T LOAD 206 I � � I �, 2 �:�. i S�LON 2 �� i � i i � i . � ,� �I j i f--� `,, � I ' j I � j REQUIRED EXIT WIDTH 31" � i I i ��-- , � � I �< .� s `� � � I � � � 1 i I -�' '' ,'"� � i � � � I � � I I � � I '`G`L` I :.;f�r� � � I � � � � � � /r��� �,� �.�.'�� � � ''�� � 'Yi��"'fi I � I I I I � � !�� � <�"", ;�%��' ✓i�; O �� � �� I 1 I � I � � � ` `� ` ' "�`"' rwirwY u.a� I � I I I � � I e�r,w � a�av4•n�r I � I � I I I � , � � ' � � � �► �' "W� �.a..l O � I:nc,, I w� 7„ � � I � � � I '%�' ��e�� r�/r. � ` 3, !; '^' ;l� � I' �s:��f��/a:'' t.c.�/ i � i :i;��� a.,.rY �,:.d' �.c6� ( � � � � y I :�y�.l,l�: � ' � � � I ( � �, � i 4� �p � � t�"'', i � � � i I � � i i � �� �..a i+F� � � " � � �. .i ro I �--��+4�--- � � � I I � i I le l�, _ --�--'----, i GOLOR,4D0 { �-----T---- � I i i � � ' ? i � I i GOLORA�DO i i , i -�. _ ' � i i B,4LLROOM i `���,,,, \ � i i � , i BALLROOM i i i ��..�.. I � OGGUPANT LOAD 630 i �-�' � � j � j � � � j � � � O i f REQUIRED �XIT WIDTH Q5" , I I I � I O I � I `I j O I � � , � � i � I i I � � I \ � I I I * i I � � � � � I i I I I � i � � 4 � l � � 1 I � � � � I � � I � i I � O I � I ' II I � � I I � I � � j � \ / I I j I�� � ryl � i / � / 1 I � I \ / i ; ,-- � � i� i i_!L�i i , � �1-i i '� i � � � E �'' � � � � � L'� � � t..,< I j I \ / �<;;<, I I � I I � �I I � I I `1 / � �� I � I \ / t: ::, i I � �� I I I � ;:;>: � \/ ''''' I I �65- O � � � I� I � �---�1-� I V `,;'°,' � �------•iF------------4-----------------�I, � 60'-O" , n ; ;: i � � _� � �4------�r1- ' � i � ��►- , �__, � i �---------� � � ! i ;:,,>;; I I �J_ � j I �_____� � ':� I ! � �----�-�.;--� � �-------�-�V----�-� � � c.�•' I I I � ,�' i � u � � ' I � �� � / \ •�����i"��<. .::.; �------�----� � 1 \.�,, I \ >.�;:°.:°� � � rj(�'-'8"�� � � I ..��_...,...., �_ ;.",` � 6 -o _g� �..� >;;:,> (�--�--�' a _$�_ �` ti\ O � ' � ,� � � i < ----- -�i� _,,:`;:.; � , . . � > . . , ,�°� ..�.. ..�... ...;.. , .....__..._..•-.•••-.•, � _ �; _` < ----------- ----------�r'- L �_ - a<::s::><: <:< � ��'` gg' �" �'� 42- O;� / 1 " I�-�-------------�1�-------- � ,--- �` ' -------- -- ----� �'_-_' �`x 112'-O"~---,=-' � \� . � ;�.._.,.�; � I �--�-� � � ; b5-"7"'J� Sa-'3'� 81-'3" � , `, i eF`,�` � . n ��:..,,::; f �����::::,,:�.�� � 0 �Gf�55 f'L.�1�— ��L1.iZOOM 2 �Gt�55 f'L�1�-5�L0 � I � �,8 .,�� 0 PLAN NPOR7}I l ` AlOR7}d ` ' \../ w r � ` � 1 i /\ " ,� {-�} —/' a+� � , � � �L aa -i i ewsn�roR�,� t.arwnorr ar oasnr�Risae�� t�� '' T �L ,nr�"�iN'ca�a u�oRS �g���g�� �` \\ '` � � �� exhnra eTOre sT�aer or w�rr si.ore `n++� ,�f� � � � ,: ewsnt�s esness s�aass e�asrn+e ears�s aooRS tY - — � � � . , I I I I EL q9'-I I'� :�' ��ro�.,iN ro ieew,u+ f�-_ eoNC itriu�eoae ewsnNe s�ers ' . � 1�� � — � �• � �L aa'-II"-�- '# � �wPat hheY/Pratt/SchuHz � � , � ,p� Architects,P C I ���1 I � � I I- ' � � All Rights Reserved � � � � ::i I P�az vo� I � -----� �'�� I I � I I � i � ��;';::.'>.' Thls document,and the Ideas >::::>::::>: >::;::>::>::: t ::;:>:.::zz: I � � � /POR PPORS � •.,•. � 1.py�RAGKy � y�w • *. <� ------ -----------�----- ---� »_::»:: I �-------F--------- ta¢s�aa¢s ---�-- I ,YaRao� � I �\; anddesignsincorporated � ------- � , � . I I r--------�"-- --�`-- � �`-- >> �>' O I I - � �,� .� _ � ::.\ hereln asanlnstrumentof I 1 � rJ I ', r• I�"� � I � � i • ' � professlonal servlce,Is the , � , � �\� �� � � \� �� " I I I � I � `� r�\ /�� � ` � Schulfr�chiCt�ctshP C/nd Is not I r—�—'—_�___� �—�V�_ � -�-�-�-�_�_�����-�_ � ��V� � � � � � � r � � � i I to be used,in whole or in part,for S�LON I - � � ��� ���— � Ky,Lyy�y� I I I ��_ � ��V_���� _� �sn�g� I ,;\,,`,c anyotherprojectwithoutthe ^<:>::::>::: I � ' >::::>::::> >..;;;;;;:;:: ""°""" z�. writFen authorizatlon of Edward i i i <::;::>::;::>::> 0 5?�LON I i �--- — - -- - �_ �,Y� � �---- � a�av4•,�r >..:::::::::. I 3 m T rtaeAa r�ursR��-� I , ��,:.; � r--------�►----� � � � ;::':;`"""':' ( I ` � ' I a�-eais•�rr ', �� � M Gwathmey Jr.Henry R Pratt. II § �y�Y� � a � � � '� �� or Sidney Schuliz � I � � e��iur � w,w�wr c�e . b \ \��` � � � � I � I � � e,�.� � `.°� , I I � d � � I i 5,4LON 3 , � i � � l MEN S � �` �► � i I � i � �_ y_, 4• ;� NIG ,,; i i � � SA�LON 3 � o SA�LO�1 2 �� - i � M�N'S ;` � � � i i ��� �, i i S?�L01�1 2 � � s�-,��4• ��� /' N I G ;,.?>.� � � l � i '� i � i I " :� Date: �UG 20 07 . .�.::::. � I T ' i � �, �. i i � � ; � i � � i ,�--- ;., -�-�:-.;.. , � � � � I � �,, � SEP O� O� � � � SA�LON 2 � 3 � � ``� � � � � ��J ' � � I � OGGUP,4NT LOAD 351 � �;�i'i:: `� ,4,..,� iJ, :�!%> � ,���,r- ;, ;�-'�;. ��'� �� i ' i `` �.. _ ''� S�LON I � 2 i i � ;,��... � � R�QUIR�D �XIT WIDTf-f i"✓-3 � w,uxnrcia � OGGUPAh1T L0�4D 42�f � I � � ir t,/;; � S�P �4 0� � t �.�_.; .,.;. i � I I � �- ,A* a�.a-v4•,�r � REQUIRED �XIT WIDTFi 65" i I I D'"�u-e-I�/+YI+�* � I � r , ,;�� ,� . -f� I I � -� . , I � � � � t�%�� �-.,.F �.'" �„a I °" I � � � `� �'•r ('l"'^ � �,r✓-'� i � � � ��l� �,.�' ���' +�/„C' � I i � i WOMEN S � � ���, i i � i � i � i sT�,�R �" I 1 i �4 �. NIG i � � i WOMEN'S � � � ' NIG � ����� � � � ,.__% �� � ST?�IR � . � � � � � . ------•i1--� � I I i ����� ,-' ' I � � � , - '- is `, C i GOLOR�DO i i_________� i i I � � � B,4 L L R C�O M � 3-_�, i i 1 GOLOR�4D0 i � ' i i . 3�- -% i � i B?�LLROOM i I , - � i I i i i i i i � � : ,`_.% `. ; i i i i � � i i � `� �„` I i i ���r��� i � � F C ` � I I � riwsrrs � I ����-ors r+aae riRe rs,n�ec naoR R � � I � � l � �—�i�ro�w�rcM'E°ex� j I i �� Renxe vcmnra aooie wi � � � � � I � I +�eru+nN Tu w,x.H e�cr�nNs I � � � I 1 � I i � � '\ riw� �.�1 � I � � � � � I � I � �I i � � r t : 6 � �J.,�. � i�l , 2 0$5 � --�- � �--- I � � � F:::: � �' �58'-2" __f9 � �� ir ✓ f- . �-� I I r'.::;; � I . I I 1 / t ::.:: i i L�:1 i �---�- i i �� �� i i 1��:� �� i �v � � � , � , � � � � � �► � 1 � � � �.'� :..:; .. , :.:: .:,,,... � 1 I � � , � ,� ; ,;, � � , � � , � ::�,:��.: ����� I � �--�-, j � �----�-----� � ��` F `'� � � � i � ri ����:�' ' � � '� I � ' � � � I 06'-4" � � z: �. � E:..: I � �� i, i i � i i STORE i �� ` i r � F:• � � ; >< � x I r � i i �---� � --•�---� 145' 6" " � � � N I G � � �:;,�;: i �..�:..�........ � ��i STORE � � __�..... •�•� �. _ "'' �------------ � 82'-b" �------ � � , � � , � � '�'� �" �---------- ` '� � I 80'-O" -< I 68 -a � --•F--------- �----�--- yC �-►----- � � � � ---------�-----�( � �� . --►----�� :' NIG � ` ..:°;�::°��:��� -�58'-b" �----------- ---68-8�'j( �`,, w :�--� \ � 1 �;;>:°<�<; ' �� -� ! �`t Shaet �lumber 4'-10I/4' :'� ;.. ;�•°;�;°;�: r-o. a k`.•,`; _ �. � I' ' � ��fi?\/I/� r/�C7R7 I1")/'1i? I�.,,:�, s�ao vt• I.a � �� ��*' c,�a�iir� rnrvt�ir�nt� _ V I .I � � �Gf�55 f'l�rl�l— 5�LO1�1.5 2�3 ' � �C��55 1�1—�1�1 — S�LONS I�2 � � �,a•.��� P�ax _ rrortn+ pt.o,x �� I i f'f?�OJEGT SGOPE i Gwathmey ; � � �����Au�n,��M�� Pratt ' 2 �Q`���'ST"��,�� Schultz � 3 REMOVE AND REPLAGE PJCISTIN6 YVALL GOYERIN6 " 4 REPL4G�UN-RATED GEILIN6 TILE AND 6RID Archltects,p a 5. GLEAN 3 TOUGH UP SPE4IGER GOVERS 1000 S Frontage Rd West ._ b REPLJtiG�DOOR BALLROOM DOUBLE DOOR WITH NEW Vail Colorado 81657 D�OR AND FRAME Tel (970)476-1147 Fax (970)476-1612 '7 CANSTRUGT METAL STUD AND DRYW,4LL ENGLOSUR�S TO GONGEAL OP�RABLE PARTITIONS PINISHED TO GOORDINATE WITFf OTFiER FINISHES 8 REPLAGE DOOR HARDVyARE ON ALL BALLROOM DOORS . � q REPLAGE DOOFt.,AND FRAMES INTO IGITGHEN . F. � ;�. � 10 I T BATT T O R TO , �, ' EXISTIN6 SIDEN4ALK TO MININ2E SOUND TRANSMISSION BET'WEEN SALONS � F� ,`..\ J' ���N II INSTALL GULTURED STONE GOLUMNS,4T YW4LL� �NGES � � r� , � .�. � � .\. . 12 REFINISH/REPUR615H/PAINT ALL DOOR� IN 8,4LL.RDOM ; f . .` . , 2 � � � 2� EXISTIN6 GONGRETE GURB 13 REMOVE ALL ITEMS SHOWN HATGHED � ,` O � I �; � � ���G���� 14 INSTALL BATT INSULATION ABOVE YVALL SETWE�N �� G O. � N � RAMP BOTH SIDES -TfP BALLROOM AND SIkTHROOMS � IS PROVIDE AND INSTALL NEW AIR iNALL PANELS � ,, E Y O N D�R�A M P E D 6 E SION d � � REQ�UIRED OR NEW flOOR PFI�LSEGTIONS OF'TRAGK OL ` '� I-I/2"DIA STEEL PIPE RAILIN6 TYP z � � � •` , * RAISE PLANTER SED TO LEVEL � 0 N i'�A' i'� ..; OF NEW RAMP _ �1�{�.I�y� IW 1�..� � RAISE PLANTER BED TO � S,E4NDISET PA1(ERS-USE EXISTIN6 � ����,y�� O � Q I ALL DIMENSIONS ARE TO FAC.E OF ROU6H STUD,FURRIN6, � � OR GONGRETE POUND/4TION NV1LL,GENTERLINE OF � ' ' ` I-I/2"DIA STEEL PIPE RAILIN6 POST —� �I���'`',��'' ¢P�� � O SET IN PIPE SLEEVES -TYP DN � �N�GTOR TO YERI�T',4LL DIMENSIONS d NOTIFY � � ` * 3 R � .��� ARGHITEGT OF ANY ERRORS OR flISGREPANGIES BEFORE �� \� ` ` ' BE6INNIN6 WOR1C EJCISTIid6 PLANTER o.� , �� a y ` ❑❑ 3 DIMENSIONS 61VEN ARE SUB.I�GT TO PIELD CANDITIONS � AND M,4TERIALS d METHODS USED GON'TRAGTOR SF�ALL � � R�,7' 3 � FIELD VERIPI'GRITIGAL d MINIMUM DIMENSIONS AND �. GLEARANGES AS REQUIRED 5Y APPLIGASLE BUI1.flIN6 �L �f� I I � �-�'- o co�s i i_ ii EXISTIN6 STONE WALL Af20UND PLANTER / � O , � EXISTIN6 PORGH LOGATION OF EXISTIN6 RISER�� � O 4 DO NOT SGALE DRAWIN65 GONTAGT ARGHITEGT FOR O START OF RAMP SLOPE DH � \�jeP ANY DIMENSIONS MISSIN6 OR ILLE6IBLE EXISTIN6 E6RE55 DOOf25 EXISTIN6 E6RE55 DOORS -n � TO REMAIN TO REMAIN GONG INFILL ABOVE EXISTITy6 STEPS \ C�" , � ' ' '� .'� 5 ALL INTERIOR AND EXfERIOR PARTITIONS ARE TO BE � O \ � � IN5UL4TED 1W PULL DEPTH UNFAGED BATT IrLSUL4TION. 06 �O5 4 ' O3 �L. qq'-I I' SPE f'R0.1EGT MANUAL FOR REQUIRED ACAUSTIG t '1 ! O � ',j' QI GAULKIN6 AT ALL P�RIME'TERS t PPNETRf4TION5 � �---Q- _ O f b ALL YVALL,GEILIN6 AND FLOOR/GEILIN6 GONSTRUGTION IS � � , TO H�5 8"TYPE 'X' 6YP SOARD UNA �`'.z�'`s / ( � �..... ���� � R_—_ _—_— I — G___ I I 1 - 1 � I , , tic i � � I "1 PROVIDE SOLID NON-GOMBUSTISLE BLOGK N6 POR � I NEW TRAGKS . ,. INST TIONS RTWORK SY OTHERS / � � ARTlNORiG ALLA A . . W TRAGICS I F M� OR DOOR� � 2 . m � / OR DOOR� I I � �-1--1 � . � � , , � -C G . I � i � � .� �8 . �� , ,� �. . i I I�" � '� i' � I C' '� . � O . . . � \ , , , D�2 � , , � �11�115� SGH�I7U � . L 'D�R FAR SIDE � � � D3 O � � b .3 � � / 4 I 02 ': oF o i oc . . I � � L AD N6 D �� � i � �� �i �i ---- O ----� ---- I F 1 1 G����� 1 1 � I V I I V I � � �� � , � O --�-- - � - ---------- ---�--------��-- ,:�_:.. ----------------- ---------J�---------�---- S� O�l I __ _ L ����T �T N PJCISTIN6 STONE I EW GARPET I T HA Y G 6 � � TO REPLAGE EXST I LLWA L _� ��.�. � I - - 8' 3 I 4" �F I � / A � • I ��, � � � � � `_:>::>':<:::::'>:::::><:>;:::><.a::'s:><;>;:::>.s::::>::>::::>::::>::::>:::>s:::>::::::a::>::::>::::<. ... .:,:: ;'�>.:::ii::>.�::'<:><.:>.:>.:>.>::>.:>.:»><.:::::<.:»::::>:<:>.:>::::<.:>:a: " `'. <.. '<:::`::s::?::���::i��:'Ei.??.:s?!?:�:?8ii>:�iiS;>Si?.iii?21>ii;22 I I p ��----.....-�--i-� Ff,4LLYVAY GL6 � � � ' � � � � ---��---------� �--�--- I _ i � � - I 8' o" ;<::�€< I I �. AFF ::�:., � \ � � <��?"w�� � :�.� � /� ""�v""""""""""�"� /� ♦ I� .��>`�a<� ::`\�6c�`��:� �:O\. ..\.���.:`\ ,\>:", O � . 1 �y I I\� �'t :�v\:��;�:.:���.` ..\�::���<�;.���;: `�'1 �\,. .��` :�.�\<� I ::�\,��:c" ��.��..\:.:\i�?`: , ' r.// \LOI ♦ ✓ ">\'U����\:.�\\..�\�a\.:\.y. c>4\��:" ` , I � � I �j�:��Q.:�:a.\\\:` 1 i ..:\:G:\�c\\��:.���::�\\�"�::.`� �t��'���� � M�N 5 :;:.. .:�..�. .,. .,..... � ::.,:::..,::::�,,.::.:::.�: �.:,.:...:`�:� � � .,. ��.�...�. � 1 � ,rE '�. :£>�':<.;>,E'<:.>,#i.\ � ' ''�'`� osi°: ..:....::t 1 :`:::�:�:v't 5'-"I I 4 / /� S� O�! 2 J r NIG L -�_ �,� , � � � � � � �::':::::''<::',:<::s> _:<.�<:::::<:: � � � � �,. � ✓.� � �� � - ll � � V � ,� A � S f r } l I ` '\ � N � t � ` /�� 4 / I � ff � FC I \ ' i � \ � � I � �y I I � f J<� �' + , va • I ,� � �^ , . .. ' I ' �y` �� 7� `� �""el fF��J�. �f'�/ff� � � //`,` � <� 1���/ '��f . L � � ""/ �� J' •\`��' fiALLWAY GL6 i ' I � 8'-3-I/4"Ai� DN I I �;.�y '�_�` ;i' ` i i f%J,.-rr.., ( /I' /�?� _���iq� i 1 !'"" `�."'`` / � . .6:� `2a!Ll.� •[l,J �'�, �, � i i '���� WOM�N'S , ; 5T�IR uP _ I D3.1 � � �; - ,, I�l I G C.EILIN6 SYMBOLS , �� �� � � �. H '��0� i i � 13 � ACGE55 PANEL ,� 0 ! GOLO�I70 , D3.2 I , ❑ ��T�Ax �� ' I �l'SLL�I�OOM I � #._ _ w�' \ - � RET1h2N AIR 6RILL p Copyrlght � � ' � . SUPPLY AIR DIFRJS�R Gwathmey/Pratt/Schuliz � 1 ._._J"° � , � A r c h l t e c t s,P C ' � � �,` -�RETRAGTASLE LI6HTIN6 POSITION /�I Rlghts Reserved � � � �''.� SURFAGE MOUNTEfl LI6FfT ih�s document and the ideas � � , and deslgns Incorporated �� ' "�.� REPLAGE EXISTINb DOOR N4/ PENDANT LI6HT FIXTURE �SE�NOTE here�n as an�nstrument of � � �ONE FIOUR PIRE RATED DOOR � Pfo�fee Ionof�GwathmeY/Pratt � , REFINISFf TO MATGH EXISTIAIb P P � � �6 �;t PINISF�S � REGESSED GAN LI6HT o b u edhln who e or I�n part for � I I� � � YVALL N10UNTED EXIT LI6F�T any other proJect wlthout ihe � (� i � M Gwathmey Jr Henry R Pratt, �22 � � wrltten auThorizaTlon of Edward TYp �L ��-� � / H �ORE���D'1R��GFFfIN6 orSldneySchultr � TYP / � I 1 / , � i � I � 11 / � TEMP�RATIJRE SENSOR �__=_� � `� j QJ J-BOX ' � r DAte: �UG 20 07 ' i, D�.2 � SEMI-REGESSED SPOT LI6FfT I ,\ / . p -} I ' I 1v � SPRINKL�R HEAD � 5�1- Q 1 Q� � � FIRE PROTEGTION EQUIPMENT I 2 I e ,(1` . . � . p �{ �;,,,,,,_,,,,_..� �� / ` Q PIRE PROTEGTION -HORN/STROSE � S�f I'7 O� T � G / 1 OO FIRE PROTEGTION-SMOKE DETEGT ' � >,-_-.•.•.•.....�� JTO�� j 1� Av AUDIO VISUAL WALL MOUNT � ` � 1 a`/ AUDIO VISUAL GEILIN6 MOUNT , � � � , �l I G � , ' ' f, ` � "t � ~ �\ ' I I � �` i�+,..::;'"' ,4 TELEGOMMUNIGATION EQUIPMENT l 08 �� 0� '; 't 1 1 I O O GH�4NDELI�R LOGATION �`. ' b" 4-10 I/4 " �i �n ; ;r' �Q SPEAfG�R 6� ¢���� 2 SPEAKER� 105" b' 4'-10 I/4" b I'-O" , I 5 ,%` ,, _ S�i�V�I G� GO�fi�I I70i� o ���R m 8.��� �� � ..... �,. , :,� f' VERIFY EXISTIN6 SUPPORT O ,,� � �'� � �, , / . ; I� FOR ALL GHANDELIERS/PENDANT �'c.� .,� , �' ���� , ��' O r" I� L��N6,RPROVIDE SUPPORT AS �'�'"� ,� �� ��� RTH " 02(3 � Y+" ::.�.:; s ::�,�.. � ..� ,` _:::�::�> :.., :;:.� ;..� :.��::�:..:.., �:c � ,::::: �..:� �� � :���_ , , ;:;;..::::,:.>.,:::...:::.::::::. .� ,� � ;':�:�� �>�:��`:'::><':::;::;::>;:::<:::;:;:����: � s � : � � �I G� GO�i�I DOi� .� :.:�: � � �� � � _ �,� �, h r ,- .� 4 f`' . ..... i::�::: $ � p �I 1 r� ! � I \ .I.G. i� 1"�'' J r��. �... 4��i �. � � Sheet �lumber � � � ����OS�� �L�l'� I� _ I SGA1.� 3/I6 " = I'-O° �� .0 ) . i i i �O� ��� ' ROOM � F I K I SH H,�RDY�►�?� �I�� i��M��KS ��J�T �� Gwath m ey - 1�10 ��„� �risi� ��Y riarES u�s� �� +�,r� � P�,xi �ir� riarES R�T I 1�1G , I REPURSISH ALL WOOD TRIM THROU6HOUT Pratt 2 REPU4GE EXISTIN6 GARPET SC�UI�Z , OI BUILDING EN7RY Pl'G '� 3 REMOVE AND REPLAGE EXI5TIN6 1NALL GOVERIN6 � . 02 PREFUNGTION YES YES 5 T D YES YES YES YES YES IANO DBL DOOR . O MIN SMOKE SEALS REQUIRED 03 SALON 2 EM' NO NO ISTI *"' NO " NO •• *'� REMOVE DEADBOLT REP,41R fiOLES FROM DEADBOLT 4 REPLAGE UN-RATED G�ILIN6 TILE AND 6RID Architects,p c. � 3 04 SALON 2 EXT NO NO � EXISTING *'� NO '�'� NO •* *'� REMOVE DEADBOLT REPAIR HOLES FROM DEADBOLT SDIJ 5. GLEAN t TOUGH UP SPEAIGER GOVERS 1000 S Frontage Rd West OS SALON I EXT NO NO EXISTING *'" NO ** NO •* *'� REMOVE DPr4DBOLT REPP�IR HOLES PROM DEADSOLT VaII,Colorado 81657 O6 SALON I EXT NO NO EX TING '�* NO '"'� NO "� '""" REMOV� DEADBOLT REPr41R FiDLES PROM DEADBOLT I 6 R�PLAGE DOOR BALLRODM DOUBLE DOOR WITH NEW Tel (970)476-1147 � O"I WEST EXIT STAIR NO NO Pf+�l AI PI H *** **'� '�'�* '�** '�** PIP�NO I HR* �� ��A��`� '� Fcnc (970)476-1612 OS ALON I SERVIGE HA NO NO PAINT PAINT REFINISH ""* "'** *•" "'** NO PIANO 20 MIN � r � '1 GoNSTRUGT ME'T'AL STUD AND nRYWALL FJCISTIN6 GOLUMN d pq SALON 2 SRVG HALL NO NO PAINT PAINT REPINISFf '�'�� *'�� *'�'� �'�'�' NO 4'IANO 20 MIN `� ENGLOSURES TO GONGEAL OPERABL�PARTITIONS STONE VENEER ,�,�,� ,�,�,� ,�,�,� y��,� PINISHPD TO GOORDINP.TE WITH OTHER FINISHES I-I/2"STEEL TUB�kANnRAIL 10 SALON 3 SRVG HALL NO NO PAINT PAINT R�FINISH NO PIANO 20 MIN E P0575 PINISH AND GOLOR II SALON 3 GLOS�'T NO NO P�41hlT PAINT REPINISH *�"�' "'"'" '""" "** MO *"* DBL DOORS 20 MIN � TO MATGH PXISTIN6 8 REPLAGE DOOR HARDWARE ON ALL BP�LLROOM DOORS i ��� 12 SRVG HALL/KITGF+EN YES NO PAINT PAINT HM FLUSIT YES NO Y�5 NO NO *** I HR" KEEP EXISTING MTL PRAME i . , , 13 SRVG HALL/KITGtfEN YES NO PAINT PAINT HM FLUSIT YES NO YES NO NO *"'� I HR'" KEEP EXISTIN6 MTL PRAME q REPLAGE nOOR�AND�i2AME5 INTO KITGHEN 14 SRVG HALL/KITGHEN YES NO PAINT PAINT HM PLUSIT YES NO Y�5 NO NO *** I HR'" iGEEP EXISTING M7L FRAME lo INST,41.L.BA7T II�LSUL4TION ABOVE AIR WALL TRAGicS To , IS SRVG HALL/STORE 1�'G MINIT�E SOUT�D TRANSMI5510N BETWEEN SALONS , 16 TEL GABINET HALL YES YES STAINED x STAINED x ALD�R YES NO YES NO NO '�'�'� CANFIRM w/ PROP I i�R MP�TGH OTHER CARRIDOR DOORS � I"i TEL GABINET 1�G , � �,_�o � Ib�FIELD VERI�'f ` ` � 12 REPINISH/REFURBIDSH/i'AIPITA�ORS IN B,4LLROOM � � IS LOADIN6 DOGiG NO NO EXISTIN6 YES NO YES *'� �..1�OR �BI�LLR�� ENT 12 MAX FIELD YERI�Y , G su�e. sia�.i�-o� � ' ��- 0 J: ,].,,`.... �� •--�*-�--.--�--��-�t-~�-"•'""��'�..�"'`"'<<"..�;..,� ,- , , ,� TO BE PER MARRIOTT SPEG5 TIN6 FINISH O� OTHER SIDEWALK TO 13 REMONE RLL I'I'�MS SHOWN HATGHPD ----'~�' . -r-.�.«..-...: . . .. . . .«.. , ::.. :.::..:. . ... . � ALL NEW HARDWARE � M,4TGFf STAIN TO EJCIS ...-<-.�--"':'>,�~'�..""`:_ � � ISSUED PREVIOUSLY DOORS Ihl HALLWAY �XI5TIN6 '` � O � _..__ _�..�,.�.*..,�-w°^.>.:;.,,....::: � : , ...,, , '�YERIFI' REMAIN � , � ** KEEP EJCISTIN6 HARDWARE 14 INSTALL BATT INSULATION ASOVE WALL SETWEEN � �� *"'� NEW TO M,4TGFf PJCISTII�S w/ OIL RUBSED BRONZE FIHISFf BALLROOM AND SATHROOMS � \ e � `�'� 2 15 PROVIDP AND INSTALL NEW AIR WALL PANELS \GONTINUOUS CA�4GRETE �,! G�,4,��A���� 2p ON EXISTIN6 1RAGiCS NOTE NEW SEGTIONS OF TRAGK � PJCI5TIN6 SAND SET ,.� EXI5TIN6 GONGRETE GURB RPGiUIRED�OR NEW DOOR PP�NEL ' �NEWRSLOPE-INSTALL I NEW GONGRETE GURS TO � � F � BE EXTENDEfl 4"ABOVE NEW i�� N RAMP BO'T}f SIDES-TYP �� �w�� O � TfP HANDRAIL EXTENSION Q X U S�GT O � SEYOND RAMP�D6E K W � I ALL DIM�NSIONS ARE TO FAGE OF ROUbH STUD,FURRIN6, � SGP�LE 3/8" = I'-O" � I-I/2"DIA STEEL PIPE RAILIN6 TYP � � � ��o�D�5 #FlDP�� Y�L4LL,GENTERLINE OF � � RAISE PLAMT'E12 BED TO LEVEL � 'I ' � ����„��� � � N 2 GOrfTRAGTOR TO VERIFY ALL DIMENSIONS d NOTIFY �'^ - ARGHITEGT OF ANY ERRORS OR DISGREPANGIES SPFORE I-I/2"STE�1.TUBE FfANDRHIL t POSTS NEY`l I 12 RAMP RE-USE EXISTIN6 � L�/PL OF�RAMPT� �---- — BE6IMNIN6 WORK � I'-O" FINISH AND GOLOR TO MATGH EXISTINb � SfrND-SET PAVERS � GONTINUOUS GONGRETE I-I/2"DIA STEEL PIPE RAILIN6 POST I 8 DIMENSIONS 61VEN ARE SUBJEGT TO PIEL.D GONDITIONS GURB 4"A801/P RAMP I FIE1.D VERIP`(GR�ITIGA��INUIMUM DIMEx�NTS�ND LL � � S�T IN PIPE SLEEVES -TYP 3�` I �NGES AS REQUIRED BY APPLIG,481.E BUILDIN6 O ❑ EXISTIN6 GONGRETE , .. < . . •. WALL Nl/STONE VEMEER .. �b ��r, � ————————— . 4 DO NOT SGALE DFLAWIN65 GONTAGT ARGHII'EGT�OR O , �� � O � f EXISTIN6 PLANTER a� �� � ` � ` ANY DIMENSIONS MISSIN6 OR ILLE6IBLE � � m � �,ry. 3 �`` 5 ALL INTERIOR ANfl�XT�RIOR PaRTITIONS ARE TO SE � � �� � �-� 20 INSUL4TED NV PULL DEP17i UNP,4GED BATT INSUL4TIOhl O ��: ��I�I I" NEW AIR WALL �XI5TIN6 STONE WALL AROUND PLANTER� ` � SPE PRO,IEGT MANUAL POR REQUIRED AGOUSTIG � ` TRAGK FOR flOOR EXI5TIN6 PORGH LOGATION OF EXISTIN6 RISER /� � �Q- I I I GAULKIid6 AT,4L.L PPRIMETERS d PPNETRA�TIONS l 1 �� �� ���rr ` � PANEL START OF RAMP SLOPE� DN � V - -- �""�``""�"-�=�-......._:: 4. i � �n"c'� GEILIN6 I I b ALL iNALL,G�ILIN6 AND FLAOR/GEILIN6 GONSTRIJGTION IS � " � � \` ��IS�TI�N6RE55 DOORS �I�TI�N6RE55 DOORS Gp� INFILL ABOVE EXISTIN6 STEPS----- �" I ��`L��F�����ORNAM�NT I I TO SE 5/8"TYPE 'X'6YP BOARD NPLO) L.r�.__ _________ �,. ' � f,� �,-' � �4� 12" DRILLED f PJCI5TIN6 SAND SET "�` / � \ � PPDXIED�INTO PAVERS -RE-INSTALL OC! ��, ;� O� 4�, TR4GK POR DOOR �� � I � R�TWORK INSTALLATIONS�P�RTITWORK BYLOTFIERS �� � Exisrir�corrc . r�w s�e .� � �, , O . ,' �� PANEL EL qq I I `�' � � (�(� s-�coxr co►���iu.ov�x ——$ ' �,� ' 1-4-1 EXI5TIN6 STEPS � � . I � =_( 1 �=_= �!._.._. � � --�— 1 � _ � _ _ _ f r � ' � � ����S�"� �''.�i��U�..� O � S�GT I Ol�l i ry� �,�� , �--..-.--- ;,��,���- p+� p� ± { } �.�bG i �� '� * { * I T Flnuhp Locatlon Metenel Menufecturer S Hicatlon � LyG' � DV� , I � ��R D��.7 ❑ �`Y� � � Pattern Malino Stripe-Cobr CM78304 Citrme � SGALE 3�8 �� � ������ lO < � e `1' rC� . < < c �� a � r a./Q� � `�� e < y � � VWG7 BebwChavRail Vm IWaACrnerin MDCWaACo�.erm s Wid[h 54" Wei htT II 20oz An Vd ` � ` � �/1 m I BacWrig Onasburg,Repeat Random,ASTTA E 84 O , ` I I S t t 1 Y I t r�� t t II��` ���II t } m ; / ` `�� ��\ i�f�II t f `�� I � CG7 Airvratl pocket vsll Corner Beads InPro Pattem 6100 Color Amber Gcau� ���� i�K� ��K� ��K� � � PK' Lq�_ f JKF: I L.K. � � .� ♦ corners Srze 1 1/2xl 1/2 full hei ht e PAR SIDE . �i � l� ` -^--------�� RID �EILIN� � � ! � 1 1� "� 1 � �� Y � � PT 1 abo�a Chav Rail Paint Ben annn Moore Fmsh Semi Gbss �L�A���7 1 � 11� � � 11 �I —(y7 ��� � � � I � PrefuncOonWall CabrHC15HendersonBUff t.AY-I GEILING � `' `' �i Prefunc6on8ebw HG38DecamrBuH I t n � �I �/ �I F i �I V �I � PT 2 Chan Rads Pamt Ben amin Moore Fnish E sheA (o , ¢ < n -o a�� 5�L �l I ry �— ------�-- ' � -- ---�- — ----- ----- --T- O i i�� ,, � -= � � � � ��t' - RF��T' �EXI9TIN6.STC?�E > < Ews6rgChairRak � ! I Cobr FiC 15 Henderson BWf _I_ y_...�---�- —�r-- ----y---��— — -�---�- �� GYP G�11.31NG � I W-� �.........-: TO�P1AGE EXST �pp�� NIG �r FS�s�BODoor I �� ( � II'-O" AP � � � ��. l O� —O � � t PT3 Schedule Paint BenartxnMoore Fmsh SerrxC�oss � •.•......< INORK� �° ar s i Paint finish br ewshng O FIALLW+4Y GL6 ! � ean,�m t�a����ad Cobr HC Concord Iwry,Fimsh Semi Gbss ( � t � -o- � � ' � � a � � , < � � y � � � � ' �.� ...�...�...._: e e e , � doorc�fve�cradTtand Palnt aa�am����e �`` �,. � � 8-O"AFF e�xooma Eeg��e sae z•�¢�xva°sry�s���cu� t 1 \ � /yA I �/�/y��`I ACT 1 Prefunceon Acoushcal hle USG Pws 991 Cobr W hite Grid Fine Line v GONTINUOUS GHAIN LINK PENGE I � I I � I � GYP GEILIh1G ' , / \J�`,/I ♦C � _ ` 'y�� � Pantiinishfordry 9fl CobrC118SravAallWhite Fnish Flat �,� �� f M i= �„����a��a���� ^ ARDUND STAIRAND LANDIN6 `'i • �� O ��� � _� G'YP G�ILING E Prs andblehansibons Pa��c BenaminMOOre NO AGGE55 ALLOWED"I}IROU6Ff FENNGE (�f � /� J� I /� I /y II'-O" i4� �b� I f � �1Li LOI\I / � f �"j-� '���s}�F ,`� �IG PantfinishDrywall i � I ✓� � �� � I / m� coffered area at 1� � � V decorah�.a CeiLng 1 ' ` " i PT7 fi#ure Paint MDCWa1Co�enn s S le Liau arl Cobr THD I i � � -- - - , r�- � ) � , � � � � � � � �� . � � � , � , . , � ' � � � � ��" PLASTIGALAMINA'I�MATERIALS WIiERE REQUIRED BY GODE P� I� NDIDED�I ORATED � � � DRAWIhl6S PREFERRED PRODUGT/MANUFAGTURER SPEGIPGATIONS MUST CAMPLY ' LAY N G�ILING r 1,.�Y-Ihl G�ILING � � � � v�Rlous�cl�cArloH sec orrs ����E�S,Ar�� Ixrerrr oF T+� io� io�� A�F � ii�-o�� a�� ! I � DN � � ' . . � A � � � � _ � � , : _ � I � � ~ � � � � � � � DN � ' � LAY-IN GEILING �r � j C.�ILINtS SY1�OL5 ������ � ( j I O'-I O" A� f � AGGE55 PANEL i _ � _ , . fi , � , i �L: I 00'-O"_ � I � o�-iop �,�� m ��M�� � ❑ LAY IN G�ILING i + � , . Y . . � � . _ _ y EXHAUST PAN �7 4 �� t� I`l I G � RETURN All2 6RILL r' i`� � Archltoc ts,P C ST�I I` P'� P''S � � T('S � �'} � ' � ( � � ry � SUPPLY AIR DIF�USPR Y t� � -y �r � � , L4[' L4c . �\� . i , E 13 All RlAhts Reserved --- � Gwathme /Pratt/Schuliz O I � i ' I /� J� I Y-Ii� GEIL KG �-7- �� -�-RETRAGTABLE LI6FfTll�l6 P051TION r� -� �OL�L�,�'t�O � -I�f� This document,and the fdeas r � II -O A� P i I I I I LI�IY�IN G�LING � � ���L���� ' " - s�'�`���u�D��`� and deslgns incorporated � i `. �- professlonal service,Is the �'! T� I� � ��T� I � II'-O" � � P�NDANT LI6HT FIXTUIZE «SEE NOT'E herein as an insirument of rr � � � ¢ � ( �' � REGESSPD GAN LI6HT SchuHz Archltects P C and Is not � properfy of Gwathmey/Pratt � 3 6 " = I'-O" � I t ' � NU4LL MOUM'ED�XIT LI6FFT wrltten authoriz ton of Edwardfor SGAL /I E�OSED TEE ' � .- b WALL MOUNTED_,GINGE °ny other pro�ect without the SUSPENSION � � � � I • � � � � I � � � M Gwathmey Jr Henry R Pratt, I EW EPT � �_ �� :y� � 6YP CiE I�L�G REPlr4GE ExI5TIN6 DoOFt W/ or S�dnev schu�tz 5Y5TEM EVERY 2 GYP CrEILIf�G � � ' ( � oNE HOUR FIRE RP�TED DOOR , II O A F , L�Y-IN GEILING , J I � Q "``-� 16 �,���5��TO MATGH EXISTIN6 H FLORESG�NT STRIP LI6HTIFl6 WHERE INDIGATED � 4 ° , � � I o'-I o" A�� �r j � I� ` O ,�r��n�s� U56-SUMMIT,GLIMft � � PLUS (TfP GEILIIQ6 TIL.EJ 6 p'`C Q � � I ' Q J J-BOX DQ�: �UG 2O O 1 � p�� p*� � Q ?�22 IrEW WA�.J- � � � � � P''C � �_I � 11' 1�` � 1 / 0 SEMI-REGESSED SPOT LI6HT r p -} -} � TMP TYP � � �• I � � �� A L L �\ !J � SPRINKLER HEAD I S�1- O 1 O 1 i �Y10'=O'I ?��� —o- �Y 3 � GY� GEILING tr /Y� I � / � FIRE PROTEGTION EQUIPMENT - --� �� -o �`� _ �� �� I Q PIRE PROT�GTION -F�ORWSTROSE � S�Q I� O� � ���_ �_W I - - - - - � + -- -- `1 /� O PIRE PROT'EGTION -SMOKE DETEGT p'� p'� � � \ / MUD IN°L"METfkL BPAD ` � � A r ' ° � ` � \ / 1 Av AUDIO VISUAL YVALL MOUNT �'-O" EDbE DRY WALL i I l � ��'�'JY��TRIM 5/8"6YPSUM PANELS } � � � � / ,` � AUDIO VISUAL GEILIN6 MOUNT ��t_,___,,,.,,. -` � ��� � TELEGOMMUNIGATION EQUIPMENT � � � � r—- � mm � � � � ,, �� �` { O GHAND�LIER LOGATION , , � t �� �� � ' L,s,Y-fN ce�� � �r, ,. 5T0�� � �� o SQ�,,� G I � I 1�G ��T� I L. � �-,.�.- .�.......� K "�� e e e e � e � ,� ••,� �o�-�o�� �F� ; N I G , � � SQ�,�m �o�„ � — - --- . . _ . � � r , � _ � � � �Q SPEAKER � 8.3�� ,�� .� , NOT TO SGALE � OS OC{ `, �'i / � ,�� �*,�;°�� �,� � I a VERIFY EXISTIN6 SUPPORT ,��✓ � � � , ° � " . . j , b 4'-IO 1t4" J I' O" � Y POR ALL GHP.NDELIERS/PPNDANT c��' � � , , � 6' 4'-10,1/ � I � 6�� 2 � � LI6HTIN6,PROVID�SUPPORTAS ,�� � , YDRS�IAI LLNEER EXIO STI�N6P OF 6 _ �'_�' /` \ ---- ,- �j\ / i }-� i -�--- PL�N � NEGESSf4RY -��� '_�20 '5 � I� .�� ;,_ ��I� X I�� G ��I 1J 0� � ' : NORTFI ,4GG�SSIBLE RESTROOM IN/ ' � � , � ., � FITNE55 6YM DOWN T'HE HALL $y�� EJCISTIN6 I HR WALL ' ° ` ,�» ' �° a`;� < > < < � � .. � ' �,�'�4r� i���� ��-o�� � 14 � -�--- ', �� -- - ---- �----, `J �� -1- A '' � .�,�, �� � ^rY�x�r�s s+pai�ri� r�w��C� ��"�'j"� �EGPI�AGE EXISIS16Tj — - --- -- - - -- --- �s�e ,..;4 l i �y `\. IN EX�IN6D�,45 SF�IOWN � S�fi��I G� GOi�i�l I70� � ' • �,�°�,���S,�Y �'"� N.I.G. � 5heet 1�umber , ' ` * � ', `` NIALL PAPER PINISH AS ` SF+OWN ON EXISTIN6 (- -- � • DRYYVALL � �2" NOMINAL GUT STONE BUIL�ET 5Y S�JBE�NIIRAGTOR- ^ A�NDT�Y UPIS N OBBY� �� •O� . ►��TIES�Ib O.G E.W. ��O�OS�� ���L�GT�� G� I �L I 1�G ��L�l�l � ST01�1� �1�1���fi� C�SGOI�IG� SGALE g,�6 �� _ ��-o�� � � SG�LE 3/4 " = I'-O�� i ' P1Z�OJEGT SGOP� Gwathmey ; . � � ����a�W�,��M�� Pratt 2 REPLAG�EXISTIN6 GARPET SCh�.J(1 Z S R�MOVE AND ftEPL4G�PJCISTIN6 YVALL GOVERIN6 , „ � i . Y � � .. F < 4 REPLAG�UN-RA'I'�D GEILIN6 TILE AND 6RID Architects,p a - 'O - °�a``,'µ:•Y � . ` �� 5. GLEAN t TOUGH UP SPE4KER GOVERS � �`��� t+� .,,.Pd�t,�sA"l je:e��a:ai .�1nS�1 'tAt"�t€�CS'�;� :<<'��5 IXr:+CH'„�-uT.�.t:d 63�sk� �'�.r�:`r '`=r -�T �'� �;t ��„�e w,. A�. _J►'�5 �!N'p4rt�tiG I IL�A II�LJI'111JIi� Ik� F��Ory�BmwJ 6ac= _ Ps�u __�J � ��.• 3�Iaa�a f=�'i�i��'.� �Xf.�'r�t�I4413Tk�.Jf3$�!R ;i��S���tTK�Ef[7eg�� �:51�. <��•.�..e....,M....•a.......�'��`�`' ..fii�._.._ a ,} QY a,s°t�u; .,:gM..�^, 1000 S Frontage Rd West �� �`--+x '=rl 1�ti,y"��� �- � L'�oC la+: lly� _ , � � �1kYJ 3} !=1'°y'^.'�'�o3ia=° .:�G I.� e.a'>>t_t;uc,3',: 7°4d� �'d< " .. .......L�E���_� °;t�:;�t S�l'�? F!i<j�i t�.�t?.�..:•i'C ('�°:3,a iS;E1 �Y' P '� .;.,.,._,,,,.,,.i�llstl�tly� Vall Colofpdo 81657 ` �' G ai Y�!'�.41L�1� i�i .7r�1 �.at5t_.-INr 1: FDb IKo '{ �' _ ''l �;�4t3 �'�"r x R e a�ia �iPt Pki� ....s"� '.. ° ?'{ , • 6 REPL.AGE DOOR BALLROOM DOUBLE DOOR WITFf WEW ,�,--. Tel 970 476-1147 1 � ' f � [2:.,.�:^�t,';{>��3'ti"�'r � �, � 4���+�1• `�,�,`F<' s, ,y r ° ''`s'a . ti>�`i I�s�•4ai".".1t,'') �� w:f�.t�'":�.< :t1:�3�"sr#rr�,ti�"� Jts'��'�',.,,-z*=„�s�.,.„�hy ,� '•:°,,»ax-,. I�OORANDPRAME C ) �� , �r� s - � t ti v �� :�.,a�;.., IY�r�:.+��°s .tiyf.;.:�.� ��.e���"ark,.f.;�3�r�a I���r��avr� ' ,,, . • . � � � .�.,..;i....,..• ,r ,�r: NI !U}i I.1 i a r�a� . �rvi,7 +r� 5_ -�-� Pro�cit � ' �', '� s .�,,,,,,,,,_,. -t"� :`= i:''.X ry .. s r Fmc C970)476-1612 � ��' i C� �x�:�#'"1I�7 ^'�' a r,,�"t.:a;�-�<, �4'i f3�s f5'�'n P'>:�i�? P'�<r�L.��"_....:�........r , �"�.��,�'.a. Y�'�.e�.rc^�•Lo�°� I.F_JL�A-4 �r '� Yr�Y7�3�.': f r-- . '•� Clcrvt -��+ -�' . �Y.':fi•�t I`:6� 5�i *P,v„?M°_�xi ja„ .F ;�",._�r�..:`� �„-a�`M..,..:.. ..,��,,,, � 7 CANSTRUGT METAL 57UD AND DRYWALL _ �"��`�` .� r�,�.� ��9�'h 7"}YTiy i �lirnet ��,.�:�'".�.�a�l..�,.. j'�:..s:).. "�"�.•.� 9ta >i'�7 N F: ENGL05URE5 TO CANGEAL OPERP�BL�PARTITION5 PINISH�D TO GOORDIN,4TE WITF+OTHPR FINISkES r �2-7 i}r� �,�, °� 7 - ❑FI�II'Yliilily =FIn51 (;�x w�.3C.'�. l.°a�,} "�st �?"3^:�'s�,'�'� t fwral��i'r3e3'ry ::,?h'a1�'1 .. �"�a9<?:�6��'�f; f4.,��Y'�{"'�1i�1 :P':Y:31(i3sb�:�''p � IIt4�l 8 i2�PLAGE DOOR HARDWAR�ON ALL SALLROOM DOOR� I . ' q R�PLAGE DOOR.�/kND�'iZ4ME5 INTO iGITGHEN 10 INSTALL BATT INSUTATION P�OYE AIR YdALL TfiAGiGS TO MINII�E 50UND 7RANSMISSION BE'TINEEN SALONS II INSTALL GULTtJFtED STONE CALUMNS AT YVALL� I1�lGE5 M L�r^ ' .r,�.�p.....�ff,���',.�� ' t! S'�.r',w:.r 3 ;��it..�.... x y.�" ° :,, r' , tF. f�� �- 12 R�FINISH/REPURBISH/P,41NT ALL DOORS IN SALLROOM �"°Y't� �fri^�.�yY.ai.Y �..,.. ',.�F�,13:,.',d'4, h~M,,�':" yi? F•• , ,•;A••� �; •nj q i (.r 3^.r`y" r�� ' _ v'�j�y� �, � � k.h.J b�e�e�"�� Y �,; •`�'V •/••�� � � ' # 4.:. t �„''.,., �"a. ,•'�'G,; , ..<fr=`}'_ ,..:.,.'�N° " �y Y..,.. �.`�a�c„;a ��,. .� 13 REMO�/E ALL ITEMS SHC�WN HATU�ED y` t;,"' 's, j .� es�� { s� y� � . ;. t,.., O fP y� � 14 INSTALL BATT INSULATION AB01/E WALL B�'TYVEEN i . ....... � .. ....,...........,.m....».............. ....... ., � s ... .. t ..... .. .. .,... ..,...:. .....,.,a, ...,.,..„„.„,., „°.-.°°<°,. . BALLROOM AND SATFIROOMS � � ,� _, w ..,,�.,.,.,_..�.�..�..w.. . .. ...�,�.., . .. � ..,... ^ .........r.......� I5 : r�, .+t °" � ,� ,:' �.: , ,�.:.,«....�....;,.... .�.,:_,...: . ....,„ :- PROVID�AND INSTALL NEW AIR YVALL PANELS . . ,,,,st.,,_. - _ t�- ; � { - _ ±� ' ` m ° w }m � � Ohl EXISTIN6 TRP.GiCS NOTE NEW SEGTIONS OF TRAUC , _ y r � � - X � �. : � -. �'� x°�" �� €� i; .�-Y� � � � � ��-�..,. R" �. . . . � .. . ..-.0..w �;. �"`t . " ,_,,,, � REQUIRED FOR NEW DOOR PANE1. � - � �...,,.._.�........................� c, ' � ��i�fl'� ' r~�; ' . ��,�� .e r i fi * '� e , . , �....'_'��.�...m.<.,.............M........�,�_....._..�..M.,�..,.. , �x a� . =r • - - - — �`� , tr 4 ..._...�..>. .. ., ; ... .............. .... .. .���._..__.. ; � _.m................_.._... . .. ��� � ^� m� � f � �� �� .. . � {. ' ��� m,����q�: ` F � �,_ . I, , �'�,r faf � , � _ �- w. ..� �� � .., .. ,.. .........__:.. ...�..........��..._._...�..... ` _..�..,�.._.._,.,,, .. ' � � �°' , .�..�._...... � V � t$��L � O , '9� �'l���'?:,�'�.....�....�...�.....�...�.�.� ..�. _ ���`` -� ,�'' � � ' , � � �°�° � � � , � �� � � � r�" �.h ; ' ;��� � I ALL DIMENSIONS ARE TO PAGE OF ROU6H STUD,FURRIN6, �'�. ,'� I 'i - '�� � � � � . OR GONGRETE�OUNDATION NWLL,GENTERLINE OF � �I � �� . > r ``�v.. ' ,1� j I �� _ { _ I � • � t � � _ ��, � �„ „ "'�,..,, . ,� ,� WINDOYVS,DOORS 8 P0515 � O � � . �4 - .' f � r C ��:, f` �� 2 GONTRAGTOR TO VERIFY ALL DIMENSIONS+E NOTIP`f � � r,4 .r Y � � ,��� �G+ , � a� � } i� '���x.��....�. .n ,w�/, � � �I �� � � r ti � z. � 3 F� �t .r € �3 �E } � #+F � _� � � I f r�.� j {. �r. i � i +�s T . � �� B ' ��_ .._.... �'� .. i-.m t"� s�a�'�� �� � , � � „ . . ..............�.. . �.,.. , ..,...,.�...r�...,o..,,.... , } �� BE6INNIN6 Y`IORK ARGHITEGT OF ANY�RR 5 OR DISGREPANGIES SEFORE _r� � i i _ r � � � � 4 � d' � ' x� ` t ,.,,, ... . .. ... .. ...o...,,.. .,..,..� .,. , ... .,,,,,,,,,, ~ � •r .,�. 3 DIMENSIOI�LS bIVEN ARE SUBJ�GT TO FIELD GONDITIONS I . . .,y:y"'}.:_'�`,:,•<%� � ��;�� �<�`�z' .�:, .�`.���:�G�y �� � '° +�.�,�" "�'"�,�a "�� � AND MATERIALS d M�THODS USED CANIRAGTOR SHALL y , ., r � � . �. . i,• . �ti � � �I � � � ` VERIfY GRITIGAL d MINIMUM DIMENSIDNS,4ND I ; � .. � , ,_ ,�_.� ��� � PIE �.� � r� �y � �''''.f�'�r,<'�� ;�,!":�` .. ��� �,r� f F�`.. .?,f,,�''�.�f� � ,.^a'w"�' _�.,,,.�.....�.. >..>�,n...,��........ .,, r . .. ..«..,..,. . . . .�........ .......m'�r�.....,,.. `t":.� GLEARANGES AS REQUIRED$Y APPLIGASLE BUILDINS . . •- - -----+---��- -�--- -- - --- - °- i � �t� ` � � GODES , � , . . -.. � s.��s .,. ' > w.„.... m. m„ i r , � �,„,>.... .. � i �.'�.',r�sd i.. �;� ,�' �` :, _ �..,..:.:...:, .:.......,. ... .. � ...<..::........... . � � � �' i � �+� I # � . , '�.�",> �•�`-<r' � ,� 4 Do NOT SGALE DRAWIN65 GONTAGT ARGHI7EGT POR O � � � .I �--- ---^'- - � ` ---- - -� � c � ,� �'� ,�, .�*; ;a ,��., � �� � , ANY DIMENSIONS MISSIN6 OR ILLE6IBLE O � i� I F . �� � k., rr'�"� t��; .�,� P�}.a r'",,y�.. E e �` � I k� . . _. . , � ��., > . �i ,# � � ' — -- - - _- - � � ' , � :,r�„� .r��r'�3� �.. ���"t��y-�� ` �£� ... „ ..,_.�s ��a ,� �'s' -yr '`,.:8� r :;;�._�.5 S IOR AND�M�RIOR QARTITIONS AR�TO�� --- - €`'�a• F 1 1 ��'� �„�„^^� N �.� �� � �J~��..�� ! I �—' r � I � , � � 1'� __ _x4 ; aas ` , ALL IHTER O ' � - � I V��� �M�P f���W ,� > t �"" INSUL4TED W/FULL DEPT'+�f UNPAGED BATT INSULATIOK � - - "' � I- + ; �"';�9�:x,����� t � �:��k° •°���' .:� � SEE PRO�EGT MANU�4L POR REQUIRED AGOUSTIG � GAULKIN6 AT ALL PERIMETERS i PPhIETRP�TIONS � l ` --���� - .; �'.' *� � � � V `�� � r � � _�- � ` � - � � =} `�" '��' '�' �"��`�`'.:§"'f 3 6 ALL WAU,G£ILIN6 AND FLAOR/GEILIN6 GONSTRIJGTION IS i , � 4 r�1' � �`+ f+ , —--1' ""��� ' ti� r{� ` rf f ti. ' � s J M _?....V�. ... ��^ � t . w .. �w^t e .,,., z � ♦ i� _ � y � 3�- TO SE 5/8"TYPE 'X'6YP BOARD(Uh10) r`r I i 5 t .....3'a'"'��,�.�g.�.:�:} � ,�. i� .,.. �`"'F'.' ;:<•c„r �� ' � s i�, Y.,.. � ,y � °`$ � "1 PROVIDP SOLID NON-GOMBUSTIBLE 2X SLOGIGIN6 POR i 1 _ }`t a ,J""Fz�f� �"� ,:' ';;'""...�r„`„"`�F�b;'' ARTWORK INSTALLATIONS ARTWORKBY OT�I�RS � 7 i � � I _ t� � kl � �.� # �` � � .E'y�"'S F ".� a"' „�„� f �3 .v e ., . . ., . � ♦� '�11 y .., � .... ��'}T'� �k.� ���� ..... . � � `_ � ` � `' . ��� � �� �` m� I1�15f� SGH�f7UL� I r -�' J �` � � mm �°• < u f �'�'�Jk" �°j';� . � O � � ,� � __ --- - � • < . � " . . . . ;> � _.:. _� . � , ' ''7 T' ,� S ; ��," ;`£._. ;.", ;?.�; ,"�ro , ;.,.i �'�� F"a ""' ,,.�, �`, 'f c.:;_ !, � l� ��., ,: ,'' � �� , Y„at ,. �i�� ,„.,.� ,, �' , s..N �..^ � I � ' �ly ` , t T Fmnh# Locetbn Metenel MenufeMUrer S 111cetion 'ti { j.� � } `� �.c `F y'I d,,;a ,�i . f „'� r ^I` Y �.1 'F�M .� Y� �:4 cj,'v Pauern Malino Stripe-Cobr CM783o4 Qtrine� ,F� .I ,,, £.t�, �: l:,w' 4. � � r �`a' s .. �� �S �' L ��.; p°'c•^y ,.• � � � i_„ >.., ��''� �° VWGt BebwChairRad Vm IWaACrnenn MDCWaACo�.erm s Width 54" Wei htT II 20oz hn Vd `^� ' ' f 5 r�� ?. 'i $ Y + ��.� ? � BacWng Onasburp,Repeat Random,ASTM E _ , ;,..- ,.x ..�a a , .. , x,�" r` ., '��.�s . .. ., , - - ..... �^a� , ., e�" , , .,�. .„ ,.< � ,. . . 7�' . z S / H»��a ..f ..� a . _ < a. F .., . ..°r�^"'TM , a`�f ��e a� . + �.,• . ��"�`v w �a ,�,._ �t a'.. ,"...s .., r E^`.;r�;, �'.', ty '�,, �,,,�'r� a�1:. .. �t �a .. r<>.,�,,v ,. ? . . `� . . . ,"; �+.a M ,�� � , j ;,. < < f 'x �• ,�.. >° • �x+i • . ^ .. , .. .- :"';i i'. :�E.f ' r...yf y. t ' i'�'3 � . r . , o f .s �'� i::. � ' � 7� ��" J':.. f .. %.,,a .r F':• 3.;�>< �, � ,.:i ..�, ,; xr'z',T Y �F '�" ��r „, � �� ��� �� �� � ,a�,.,,„,,,,,,,,,,,,,,,,,„..,.,,„„ .,.,V.............,...,.,... , �. , .,� .„ CG1 Airvrallpoeke[wall Corner8eads InPro Pettem 6100zColor AmberGan � • _ ' Size 1 1/2z1 1/2 full hei ht '�;• :.. 3.";.. ,� : f .. �£;.� f corners � � I ......S:,s...a �,„� i: ,,. „a `'�£ . , . ., . > ... s fi , , t ., . , y ri.,),`m .,.,. (..,.. ..,, u .•�> {I ;.,f „� r.� �..�"" PrefunchonWall Cobr FiC-15HenderwnBuH ?' �a � 1 ° ' Q, • `.s �:'� ` ��..t " <�i:} � +��:'. lA"'� M� `:��r�'�i`��,�i C,., c PT 1 ahoee Chair Rail Paint Ben artpn Moore Flnish Semi Gbu � � � ' M . Prefunc6on Bebw FIC-38 DecaNr Buff � LI I ' Ewshng Chair Rak I ' , ' PT 2 Chan Rads Palnt Ben amin Moore Flmsh E shel O � ' I Cobr FiC 15 Fiendermn Bufl I „ = Door Frames&Door Tnm See Door � t PT 3 Schedule Paint Ben amin Moore Fnish Senx C�oss `+��' a�� � �f;•' ^S•.,` r".e .•a:s o, „I r :;f •e;) :" e �� � Balkoombase panted `r"� �v''i � " lo..;e�,iv F�r ?"�: > ;`�{..,, +�^Vt o .... �.?. • � Cobr HC Coneord Iw Rnish Serm Gbss O � � � �'�"� �� �"P. �� �. .� � � PT 5 Paint finish lor ewsh iz � ..,..v.....�,..,,,. . �J�....�:�. � a� ...�>w�.+..e...a.o-.w..r ..,.....,.......,..�.w.w......,....,.,..,..»..,,,,.,v...... .. . .. ............e..,. T�9,r �9 . /� � ..� .2,. 1 eaw� \F.f P k ♦ 3''�4, � Y•+c+„ � ° ... i:r �.d> ' ..S x g n i':b c;,,.> f i, . ... , . :;; :.. �Y� ... .... . ; , ., o.. , : : , ... . ...,..o-m�w ... . .�` � doors Lre cabmet and ser�ce door tnm Pamt Ben artxn Moore ` ' BalFoom 8 Edge-FLB Sae 2'�¢SGVa Sryle Summt Chma � ` ACT 1 Prefunceon Acous6cal eie USG PNs 991 Cobr White Grid Fine Line v � Paint tirnsh for drywall Cobr C 118 SnwNall W hRe Fimsh Flat r r sofid hveen cei ing PT 6 and Ole transtions Paint Ben artxn Mt�ora C F,' � Pamt Lmsh Dry wall ' S coHered area at ' � � � decora6�e Ceihrg PT 7 fi#ure Pamt MDC W aA Co�erm s S le Liau ad Cobr 7HD f NOTE ANY NUN�ERS NOT SHOWN ARE ASSUMED NOT USED PROVIDED PIRE RAT'ED r PLASTIG LA�MINATE MATERIALS WHERE REQUIRED BY GODE AND INDIGATED ON DRAWIN65 PREFERRED PRODUGT/MANUFAGTURER SPEGIPGATIONS MUST GOMPLY � �M� ��l�l�� I � S U��''O�T ��1�1C� �O I 1�1T 5 U�'�'O�T � I� 1��L�. S U�'�O�T �NITH 6ENERAL CANDITIDNS,�8���►���5,a,�,� �,���T� VARIOUS SPEGIFIGATION SEGTIONS � � SGALE 3/8" = I'-O" � SGALE 3/8" = I'-O" I SG,4LE 3/8" = I'-O" � � C.�ILIN6 5YMB01.5 ; ' � AGGE55 PANEL ' � EXHAUST PAN . � RE'111RN AIR 6RILL p Copyright ❑� .°.UPPLY AIR UIFFUSER Gwathmey/Pratt/Schultz Archltects,P C i -Q-RETRAGTASLE LI6�FfTIN6 POSITION f'JI Rights eserve , SURFAGE NIOUNTED LI6FfT This document,and the ideas and designs Incorporated I � P�NDAFIT LI6HT FIXTURE '6SEE NO'T'E hereln,as an Insirument of professlonal service,Is the � REGESSED GAN LI6HT ScFUItr A chG ctshP C/and Is not to be used,in whole or in part,for � WftLL MDUM'ED EXIT LI6FFT any other proJect without the wrltten authortratlon of Edward �' � WALL MOUM'ED� NGE M Gwathmey Jr Henry R Pratt, or Sidney Schultr I H FLOFZESG�NT STRIP LI6HTIN6 i � � T�MP�iATU2E SEN50R � QJ J-BOX � 0 SEMI-REGESSED SPOT LI6HT DQ�� �UG 2O O� ' � SPRINKLER HEAD � S�f Q� 0� I i � FHi� PROTEGTION EQUIPMENT � Q FIRE PROTEGTION -F�ORWSTROBE � S�I- I� O� ' OO FIRE PROTEGTIDN -SMOKE DETEGT I Av AUDIO VISUAL WALL MOUNT , �� AUDIO VISUAL GPILIN6 MOUNT i ,�1 TELEGOMMUNIGATION EQUIPMENT � O GF+AI�IDELIER LOGATION i Q SPEAKER � Q SPE,4IGER � 105' � SPE4KER�8.3" ��Q� CO ` � �H� � ' v�iFr exisrn�s st�orzr �j'�Q` R•A , a�7 -� FOR ALL G+�ANDELIERS/PENDANT � C� , L��N6,RPROYIDE SUPPORT AS * �(� s �" �j� � � �j�q ! � ��-��,i' �Y� ��� I � Sheet �lumber , • � � ��I .I � r 1 2 3 4 5 6 � 7 8� 9 10 11 12 13 14 FLAG NOTES M 1� REMOVE EXISIING SPRINKLER HEADS i � DEMOLlTION GENERAL 1 THE OWNER SHALL NAVE THE FIRST RIGHT OF SALVAGE FOR ALL MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS BEING REMOVED OR DEMOLISHED. IF OWNER DECLINES, THE CONTRACTOR SHALL REMOVE FROM THE PREMISES AND DISPOSE OF PROPERLY VERIFY OWNER'S INTENT PRIOR TO REMOVAL OR DEMOLI110N � � � � 2 INFORMATION PERTAINING TO THE EXISTING BUILDING HAS BEEN OBTAINED � THROUGH THE BUILDINGS ORIGINAL DRAWINGS WHERE AVAILABLE REPORT K �CONTRAC ORES A�LL FE DRVERIFYTALLGEXSTINGR ON ITl NSYP IORLIT ON. COMMENCING WORK 3. COORDINATE SHUT DOWN OF ALL UTILITIES FOR DEMOLITION WORK WITH THE OWNER 4 DISCONNECT, DEMOLISH, AND REMOVE MECHANICAL SYSTEMS, EQUIPMENT, AND COMPONENTS INDICATED AS HATCHED TO BE REMOVED. EXISTING PLANTER DN , DUCTS TO BE REMOVED REMOVE PORTIONS OF DUCT AND PLUG REMAINING � � DUCTS WITH THE SAME OR COMPATIBLE DUCTWORK MATERIAL DUCTS TO BE ABANDONED IN PLACE CAP OR PLUG DUCTS WITH THE SAME J EXISTING WALKWAY OR COMPATIBLE DUCTWORK MATERIAL � � z Q 5 IF PIPE INSULATION OR EQUIPMENT TO REMAIN IS DAMAGED IN APPEARANCE N ° N w OR IS UNSERVICEABLE, REMOVE DAMAGED OR UNSERVICEABLE PORTIONS AND AREA OF INORK � w o w w REPLACE WITH NEW PRODUCTS OF EQUAL CAPACITY AND QUALITY. 6. REMOVE ALL ITEMS SHOWN HATCHED ALL ITEMS SHOWN HALF TONED ARE -------------- -- — -- -------- — -- --- ----- ------------- EXISTING TO REMAIN 1 BEAUTY 7 CONTRACTOR IS REQUIRED TO VISIT SITE AND FIELD VERIFY ALL EXISTING i ° SALON CONDITIONS PRIOR TO BIDDING PROJECT. � N I C 8 COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES PROVIDE 0 5 _ OR DIF US ( YP) � � �% TEMPORARY UTILITIES AS REQUIRED TO ALLOW THE WORK OF OTHER TRADES I TO PROCEED ' XI TIN LI HT (TY I 1 EN' BEAUTY � SALON � NIC I � EXISIING PROPOSED FUTURE RESTROOM SU PL DU T � AHU LOCATIONS H � � ° � � � ° � ' N I � � � � � � WOMEN S I STAIR UP CO O ADO � � „H.. I I � � � OUNT IN VI W � G � � . � � � 0� � � � , � � � , F I STORE , � . � , �� 18x16 18x16 + EXISTING RETURN AIR MAIN 0 � — 18x16 24x14 No Revisions Date DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, � STRUCTURAL, shop and other appropriate drawings or at site. Lay out and coordinate ' SERVICE CORRIDOR all work pnor to installation to provide clearances required for operation, mamtenance, E N I C and codes Verify non—interference with other work. DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICA110NS � � � COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby _ - granted solely for the limited purpose of construction of this pro�ect or for archivmg � � Unauthorized copy�ng, disclosure or construction use without written permission of Alwne � Engineenng is prohibited by copyright law. , � MECHANICAL � � p DEMOLITION � - � COLORADO BALLROOM FLOOR PLAN -- MECHANICAL - DEMOLITION RENOVATION SCALE: ,�8�� - , �-o�� VA I L, C 0 LO RA D 0 ' VAIL COLORADO � C � � - Alvine ' 1 � Engineering � p Omaha Lincoln• Des Moines � D 1102 Douglas on the Mall 1800 0 Street,Swte 104 4308 University Avenue Omaha,Nebraska 68102 Lincoln,Nebraska 68508 Des Moines,lowa 50311 o Phone (402)346-7007 Phane (402)477-6161 Phone (515)243-0569 ` � Fax (402)346-9576 Fax (402)477-9616 ' � ' Designed File Name � ' T ' BAH 2O069026M1 � W - �O«• e�� � � b ,� � rawn ro�ect No a ' � �4 � � RRW 20069026 o A , Checked Drawing No. �� � � ���sS����`���' STA ��NALti Date M 1 � ��; �� N �l� 07/20/2007 1 2 3 4 5 6 7 8 9 10 11 12 13 14 � \ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 � � FLAG NOTES M 1� REWORK EXISIING SPRINKLER PIPING TO ACCOMMODATE NEW SPRINKLER HEAD Z RELOCATE EXISTING TO NEW LOCATION SHOWN. PATCH HOLE IN EXISIING � DUCTWORK �' L GENERAL NOTES K 1 VERIFY ROUTING OF RETURN AIR DUCT IN SERVICE CORRIDOR � 2. E SYMBOL INDICATES A NEW TO EXISTING CONNECTION. � 3 SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT DIFFUSER, REGISTER, GRILLE, AND CEILING MOUNTED DEVICE LOCATIONS 4 DO NOT RUN DUCTWORK OR PIPING ABOVE ELECTRICAL PANELS OR IN CODE , EXISTING PLANTER DN REQUIRED CLEARANCE SPACES COORDINATE ALL ROUTING WORK WITH ALL TRADES � �❑ 5 CONTRACTOR SHALL COORDINATE LOCATION OF DUCTWORK IN CEILING SPACE J EXISTING WALKWAY - WITH ALL TRADES PRIOR TO FABRICAl10N AND INSTALLATION OF DUCTWORK. 6 FOR GENERAL DUCTWORK CONSTRUC110N, SEE DETAIL 1/M-3 EXISTING ExISTING EXTENT OF NEW FIRE 7 DUCTWORK AND EQUIPMENT SHOWN HALF—TONE IS EXISTING TO REMAIN. EGRESS DOCRS � EGRESS DOOR SUPPRESSION SYSTEM DUCTWORK AND EQUIPMENT SHOWN FULL—TONE IS NEW � TO REMAIN TO REMAIN _____ _________ __ __ _________ __ ______ ❑ 8. PROVIDE VOLUME DAMPER IN ALL BRANCH TAKEOFFS CONNECTING TO --- ------------- � DIFFUSERS OR REGISTERS � �—� � BEAUTY 9 PROVIDE CLEARANCES TO ALL EQUIPMENT AS REQUIRED BY MANUFACTURERS' ° � p_� nP 2 � SALON INSTALLATION AND OPERAIION REQUIREMENTS AND/OR BY CODE. ' � � 400 10/10 � � r� N I C 10. DUCTWORK SHALL NOT BE FABRICATED UNT1L ALL COORDINATION CONFLICTS I o i 10/10 � �% HAVE BEEN RESOLVED � - 11 CAP ENDS OF ALL INSTALLED DUCTWORK DURING CONSTRUCTION TO MINIMIZE � - DIRT, DEBRIS, AND FOREIGN OBJECTS FROM ENTERING THE DUCT SYSTEM � 1 2 VOLUME 12 COORDINATE SCHEDULE OF SHUTDOWN FOR EXISTING HVAC SYSTEMS, FOR � DAMPER � � ,I � BEAUTY INSTALLATION OF NEW HVAC SYSTEMS, WITH THE OWNER'S REPRESENTATIVE I �i����ij��%j��j���i��/��jj��i���j/�j/��� N � SALON PRIOR TO SHUTDOWN � ;%%'%%%%�%%%%;%%;:%%%%%%�� N I C '��%'%%''%�''%'`"%'''�"""'��'��� E ��,� �� � 1 13 COORDINATE LOCATION OF DUCTWORK WITH ELECTRICAL CABLE TRAYS �%��%;���'���'%� � ;;,�;,;/�;���,�/„�';�%;/;; . ����i ,��� �'ii�;.i�;�� 3%%'�%%�r%;,��;i�%�% 1 1 /%;:%;/��%�%;�% „��%��%� r,�� �� � �' '' ''� E N S IN � �� , /, „�� ,��%��,���;%����'��'�� .,�„�%!;%;;;',;� M , ; � � % �%%%�'i%� %%%''%%' �'��'��'''"""'� � 14 PROVIDE BALANCE REPORTS COMPLETED BY ABB CERTIFIED BALANCER. � ����,�. , , �� �, ,,%,, ,,,��% „�,;�% ,�%��� � P R 0 , ; ,�� ,, ,� ,� ,� ,� '''�' ��''� �''�''�� ''�''�� ''�"�� �''��' POSED FUTURE RESTROOM ACCORDANCE WITH ABB STANDARDS � �%�� ��;; �,,%%� ,���„� ,,,.� ,�% %�% %„� %�%i%� .�%%�� ;'' i;'; LOCATIONS I %'�'� ''%' "� "� '�� ,;%; '%''% � p� 15 SEE ARCHITECTURAL FOR NEW SPRINKLER HEAD LOCATIONS H „ ,,, =;;%;% ;;;;;;; ,,, , , =;,-% , %;;, %,,,;% ,%,,;, ,,,,, ;,,,,, , ,,,, ,,„ ' ,,,, . , ,,, o �:;,i.ii,i,,,i,,r,�ir„ i%%i;%i%�. ;;iiii%%ii ii%;ii� i/�i'i�i'i I U� � � � �r��ii/�ii�'ii� i�i� i ii i/ i�iiiji/�ir r/jri%ii�iii�/�i%ii/i' �j/�������//�j�����i/� i�ji�ii//ji �i�jj//ri1 ii /ii�i/. i i i ii/%//%i��i/i �j/�����ii�j/�jir��ii�jiij/%iii�i�/ �i/�ir�i��i%iii�i%�ii�� � N � %1/%,/�%// //� , ,�� ! // / //// /� I � ,;;i;;ii,i;i;;:;;;i;;j;,%;;;�;i;,%i I � i � � � � � i STAIR UP 2 � � WOMEN'S "H" � COLORADO � � BALLROOM � 1 � � m , � � MOUNTAIN VIEW I 2 � BOARD ROOM � G � � � ;;,,%%;;;,%;;;;;;;;,;;�,%,,,;,;;; � - , ,,;,,,,,;;;,,;;,,,;,;;,;,;,;,,%,% , , ;, , , ,,,;,,,;,,,;;,,,%,%,,%,,,,%;;;; ;;%,%%,%;;�%�,�� ,,,,,,,,,;;,,; ,,,,,,,,; ,, ,,� „ , , „ ,,,,�,,,�,,,.%��,;r%;,%;,%, ;,%;%%,%,�%�%,�% ' ' ,,,%,i,i,;,/,,:,;�,i�;� "�'''"„' '' '' ''' ii/�ii�''%�'%�'�''��'%� i��j��i��i/// ijjii��i/�/ /i i//i� i/�i� � � ' �j%��i� �� ijji ////////„ ///////// ////////////////////// I � 1// �ii ii��i%��i ij/r�jii �jijj% %ii��i /�jj /j%j�/ %/jii%/i //%ji�j �ii/j� /jii/ I � ,;,, ,�,, ,,,,,, ,�„�, ,;,, �%, G-1 46x22 NECK ;xi ii�,i ��,%�iri �:�ii/, ' Y�ir ii i / ii i ijji� i�ii %%; �,��,', �i'%%� �%,��% %;. T 530 ;,,%; ;�;i%, , .,. ";;ii;:i ;:i%;i�/i' !��;;i, ,,:;;,;; I i. ( YP 3) I %�j%j jij j//j jij�i ji%�i �j/r�j//// //r�// � jj/��j/1�j//j//�/1��/ ///jj///�j/� %%�j%%��j/�j %��//%�j�%�j%���i��%�j/ ' /��/���j j�����// /��/ �j%/�j/�j�%/// /./ �//�/�//// /j/��%%/�%��/���%/�// I _ /�%/�%/%�j�j�%/�/�/jj%��%%/�%/�/%��� %/��%���%%�%%/�/�%��%/�/ ' jj j�j/�j�/���j%/��%��%���/%/!�%�����/ N �j%�i�!i�ii�i%%%��%��ii/ji�/iii�ii I 1 , � � , �•��•',,,,,, � N EW 27 14 RA � F � VOLUME DAMPER (TYP) E DUCT (TYP 3) I STORE ; , j CAP OPENING IN 2 j � � RETURN AIR DUCT 18/16 EXISTING RETURN \� N ' + AIR DUCT .J SERVICE CORRID E Qj TOWN OF VAIL COMMENTS 8/31/07 ; _ No Revisions Date - DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, � �g��g EXISTING 24/14 RA DUCT STRUCTURAL, shop and other appropnate drawings or at site. Lay out and coordinate � SERVICE CORRIDOR all work prior to installation to provide clearances required for operation, maintenance, E NEW 27/14 RA IDUCT and codes Venfy non—interference with other work DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICAl10NS � m COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby � ` - granted solely for the limited purpose of construction of this project or for archiwng. ; � Unauthonzed copying, disclosure or construction use without wntten permission of Alvine 1 - , Engmeenng is prohibited by copyright law. � � MECHANICAL � NEW WORK PLAN � D i �� COLORADO BALLROOM , � FLOOR PLAN - M ECHAN ICAL RENOVATION ; SCALE: ,�8�� - , �-o�� VAI L, CO LO RADO � VAIL COLORADO � C � ' � . � Alvine ; P � , Engineering , B S R N K LER N OTE. Omaha� Lincoln� Des Moines - The entire building shall have the fire protection sprinkler system installed to 1102 Douglas on the Mall 1800 0 Street,Su�te 104 4308 UnrversityAvenue � = meet the requirements of NFPA codes, the State and Local Fire Marshal's Omaha,Nebraska 68102 L�ncoln,Nebraska 68508 Des Mo�nes,lowa 50311 � � - Offices, and the Owners approving msurance agency The sprinkler contractor Phone 402)346-7007 Phone (402)477-6161 Phone (515)243-0569 � • " ' shall re are com lete la out drawin s showin all i e s rinkler heads sizes Fa�c i 346-9576 Fax (402)477-9616 � � and locations alo g with all other required devices These drawmgs shall be � Designed File Name , • W submitted to the A/E for preliminary review and then to the AHJ for final P�a. e��s'T� BAH 2O069026M1 � , - approval The coordinating contractor (the holder of the construction contract) �v f 7; ° � ' ' shall coordinate the location of all ceding mounted spnnkler heads to avoid any �� �p rawn ro�ec o. o interference with all other trades. If conflicts do occur such that lights, ducts, � ^ diffusers, gnlles or ceiling systems cannot be installed in the locations : 33484 m RRW 20069026 o A - indicated, the interfering devices, whichever they may be, shall be relocated or � � Checked Drawing No. rerouted at no additional cost to the project The sprinkler contractor shall !�. �C,�' 0 0•0�°�•....e•°'e�� STA p � maintain an adequate supply of extra piping, fittings and necessary tools to �ss/pNAL�� so '�/I � � � make field modifications without delay An approved spnnkler shop drawmg does Date � j� not preclude rerouting if so ordered by the coordinating contractor �,� ° , � � 07/20/2007 1 � 2 3 4 5 6 7 8 9 10 11 12 13 14 _\ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 o FLAG NOTES � M E C HAN I CAL SYM BO LS D DUCTWORK MAIN M a 1 a PLUMBING � SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYNBOL DESCRIP110N SAN EXISIING SANITARY DRAIN (ABOVE FLOOR) G GAS R = 1 X D - - --SAN- - - - EXISIING SANITARY SEWER BELOW FLOOR S— COLD SOFT WATER �WC WATER CLOSET - FLUSH VALVE FLOOR MOUNTED ( ) OTHERWISE)OIVN H.E.T. (HI-EFFICIENCY TAKEOFF) S EXISTING STORM DRAIN (ABOVE FLOOR) S— HOT SOFT WATER �) W� WATER CLOSET - FLUSH VALVE WALL MOUNTED WITH VOLUME DAMPER -----S----- EXISIING STORM DRAIN (BELOW FLOOR) S— HOT SOFT WATER RECIRCULATING VOLUME DAMPER ROUND DUCT TO DIFFUSER ----SS---- EXISTING SUB SOIL DRAIN PA PLANT AIR SEE PLAN FOR SIZE AW EXISIING ACID WASTE (ABOVE FLOOR) � VACUUM BREAKER �C WC WATER C�OSET - TANK TYPE FLOOR MOUNTED , L - - - -AW- - -- EXISIING ACID WASTE (BELOW FLOOR) - '�"� cAS cocK 9 0 E LB 0 W D I FFU S E R TA K E—0 FF SAN NEW SANITARY DRAIN (ABOVE FLOOR) �z' '�,--�— RUNNING TRAP � UR URINAL �SAN� NEW SANITARY SEWER (BELOW FLOOR) C 0 C.O. CLEAN OUT 45' ENTRY BRANCH S NEW STORM DRAIN (ABOVE FLOOR) -o- GCO GRADE CLEAN OUT °O LAV LAVATORY WALL HUNG CONVERGING TEE RECTANGULAR DUCT �S� NEW STORM DRAIN (BELOW FLOOR) C 0 V ^C 0 DOUBLE GRADE CLEAN-OUT 30' MAX. 0' MAX , OF NEW OVERFLOW STORM DRAIN (ABOVE FLOOR) � HB HOSE BIBB IO LAV LAVATORY COUNTER MOUNTED � , �OF� NEW OVERFLOW STORM DRAIN (BELOW FLOOR) —H WH WALL HYDRANT (NON-FREEZE TYPE) � FLEXIBLE DUCT 36" MAX ----SS---- NEW SUB SOIL DRAIN ❑ Y H. YARD HYDRANT S SINK AW NEW ACID WASTE (ABOVE FLOOR) o��' BACK FLOW PREVENTER K �� � SS SERVICE SINK - WALL HUNG NOTE �OF� NEW ACID WASTE (BELOW FLOOR) ❑O 2 D=X FLOOR DRAIN SIZE-TYPE WHERE FITTING ----AV---- ACID VENT � 2" D=X FLOOR SINK SIZE-TYPE NOT POSSIBLE, -------- VENT `o� 2" RD-X ROOF DRAIN SIZE-TYPE a CSS CLINIC SERVICE SINK USE EXTRACTOR COLD WATER (CW) 0 D S DOWN SPOUT DIFFUSER HOT WATER (HW) o MH MANHOLE � Ms MOP SINK - FLOOR MOUNTED SINGLE BRANCH TAKE—OFF DOUBLE BRANCH TAKC—OFF SUPPLY AIR DIFFUSER � HOT WATER CIRCULATING (HWC) � � VENT THROUGH ROOF ON RISER p DF DRINKING FOUNTAIN , 180'- HOT WATER 180' 36" MAX. 180'- HOT WATER CIRCULATING 180' 45' ENTRY BRANCH J SAN SITE SANITARY SEWER �Q— PLUMBING RISER NUMBER p EWC ELECTRIC WATER COOLER �-S--{ CONVERGING TEE � ST SITE STORM SEWER I I (ROUND) SHEET METAL � 0' MAX , 90' ELBOW ROUND DUCT W SITE WATER PIPING SH SHOWER � BT BATH - TUB � HEATING — VENTILATING — AIR—CONDITIONING �--� SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYWBOL DESCRIPTION LPS STEAM (LOW PRESSURE) �'#� BUCKET TRAP CAP LBS/HR r�r� FLEXIBLE DUCT � TURNING VANES MPS STEAM (MEDIUM PRESSURE) I-� THERMOSTAT WITH REMOTE SENSOR 4�� 1�� HPS STEAM (HIGH PRESSURE) �TO"` THERMOSTAT EXTRACTOR LPR CONDENSATE RETURN (LOW PRESSURE) �"` HUMIDISTAT ' I MPR CONDENSATE RETURN (MEDIUM PRESSURE) �AO"` AQUASTAT SUPPLY, OUTDOOR, OR MIXED AIR DUCT X+4" DIFFUSER , HPR CONDENSATE RETURN (HIGH PRESSURE) ��- SOLENOID VALVE (REFRIG) END OR RISER (SA) (OA) (MA) 45° LATERAL CROSS WITH REDUCER 45° ROUND TAKE—OFF SUPPLY AIR DIFFUSER HWS HOT WATER SUPPLY � THERMOSTATIC EXPANSION VALVE (REFRIG) RETURN EXHAUST OR RELIEF AIR DUCT ' HWR HOT WATER RETURN �— SIGHT GLASS END OR RISER (RA) (EA) (RLFA) , EG ETHYLENE GLYCOL SUPPLY MANUAL AIR VENT � � S 4 SOUND ATTENUATOR D l� C T F I T T I N G D E T A I L S , , EGR ETHYLENE GLYCOL RETURN QS REMOTE SENSOR CWS CHILLED WATER SUPPLY P❑ �T PRESSURE OR TEMPERATURE MEASURING POINTS SIZE TYFE SCALE: NO SCALE auc�res 9/13/95 M-3 �� CHILLED WATER RETURN ��' FLOW SWITCH CFM SUPPLY REGISTER OR GRILLE � u PS CONDENSATE OR BOILER FEED PUMP DISCHARGE S� 0---- SMOKE DAMPER SIZE TYFE ', n FOS FUEL OIL SUPPLY 1�--- HEATING RISER CFM RETURN REGISTER OR GRILLE A B B R E V I A T I O N S FOR FUEL OIL RETURN �=J AD ACCESS DOOR - SIZE AS SHOWN OR PER SPEC ���275 p_� TypICAL DIFFUSER'S NECK SIZE, MARK A G R � FOV FUEL OIL VENT "�JZo• EXPANSION LOOP, WIDTH AND LENGTH CFM ^ D I F F U S E R R E G I ST E R A AMP GA GAGE RA RETURN AIR � � GAS �UH-1 AC ALTERNAl1NG CURRENT GALV GALVANIZED RD ROOF DRAIN � A N D G R I LLE S C H E D U LE RL REFRIGERANT LIQUID LINE UNIT HEATER FR D FIRE DAMPER WITH ACCESS DOOR ACEG AC EQUIPMENT GROUND GEC GROUNDING ELECTRODE CONDUCTOR REG REGISTER � AFF ABOVE FINISHED FLOOR GEN GENERATOR RELA RELIEF AIR � RS REFRIGERANT SUCTION LINE CUH-1 � MARK D-1 G-1 CABINET UNIT HEATER FS.D COMBINATION FIRE AND SMOKE DAMPER APPROX APPROXIMATELY . GFl GROUND FAULT INTERRUPTER REQD REQUIRED o RD REFRIGERANT HOT GAS DISCHARGE LINE � WITH ACCESS DOOR ATS AUTOMAl1C TRANSFER SWITCH GND GROUND RF RETURN FAN DESCRIP110N LOUVERED PERF CS CONDENSER WATER SUPPLY FROM TOWER FINTUBE-TYPE (SHADED AREA INDICATES ATU AIR TERMINAL UNIT GPM GALLONS PER MINUTE RGS RIGID GALVANIZED STEEL CR CONDENSER WATER RETURN TO TOWER � FT-1 �. CAPACITY MBH ELEMENT LOCAl10N W MOTORIZED DAMPER AUX AUXILJARY RH ROOF HOOD DEFLECTION 4-WAY - , G MBH � A/V AUDIO/VISUAL H RHC REHEAT COIL CD COIL OR EQUIPMENT DRAIN LINE AVG AVERAGE HB HOSE BIBB RM ROOM MAXIMUM STATIC PRESSURE (IN W G) 010 010 - CONVECTOR RECTANGULAR DUCT TAKE-OFF AWG AMERICAN WIRE GAUGE HC HEATING COIL RTU ROOFTOP UNIT OA OUTDOOR AIR C-1 �' WITH VOLUME DAMPER HGT HEIGHT CONSTRUCTION MATERIAL STEEL STEEL � - SA SUPPLY AIR ------ SINGLE BRANCH TRANSITION TAKE-OFF B HP HORSE POWER S FINISH WHITE WHITE „ ______ LINED DUCTWORK (ALSO SEE SPECS) BICSI BUILDING INDUSTRY CONSULTING HTG HEAl1NG SA SUPPLY AIR RA RETURN AIR WITH VOLUME DAMPER SERVICES INTERNATIONAL HTR HEATER SAN SANITARY FACE SIZE (IN) 24x24 SEE PLANS EA EXHAUST AIR 12�6 RECTANGULAR DUCTWORK ROUND DUCT - CONICAL TAKE-OFF BLDG BUILDING HVAC HEATING, VENTILATING SCH SCHEDULE MA MIXED AIR (FIRST NUMBER IS SIDE SHOWN) WITH VOLUME DAMPER BTU BRITISH THERMAL UNIT AND AIR CONDITIONING SF SUPPLY FAN MANUFACTURER KRUEGER KRUEGER HZ HERTZ SIM SIMILAR ' RLFA RELIEF AIR � '� RECTANGULAR TRANSIT�ON WITH C S SINK MODEL NUMBER 1400A 6490 18�� ROUND DUCT SM SINGLE MODE ACCESSORIES ' S.P. STAl1C PRESSURE SPLITTER DAMPER C CONDUIT I _ _ F B.D D. BACK-DRAFT DAMPER (COUNTER BALANCED) CAB CABINET �C INTERCOM SP SUMP PUMP 4, 18��x10'� FLAT OVAL (FIRST NUMBER IS SIDE SHOWN) � DOUBLE BRANCH TRANSITION TAKE-OFF CAN CABLE TELEVISION IDF INTERMEDIATE DISTRIBUTION FRAME SPEC(S) SPECIFICAl10NS REMARKS (1) (�) (�� • —�,.� AUTOMATIC CONTROL VALVE, 2-WAY CB CIRCUIT BREAKER W INCH SS SERVICE SINK AUTOMATIC CONTROL VALVE, 3-WAY CC COOLING COIL ISP INSIDE PLANT STD STANDARD REMARKS , _ PRESSURE REGULATING VALVE (PRV) FLEX CONNECTION R=1xD 90' ELBOW CCN CLOSED CIRCUIT TELEVISION STP SHIELD TWIST PAIR (1 ) CONTRACTOR SHALL VERIFY CEILING CONSTRUCTION PRIOR TO _ CFM CUBIC FEET PER MINUTE � SW SWITCH FURNISHING MATERIAL _ PIPE IN SLEEVE , SECTION NUMBER CH CHILLER JB JUNCTION BOX SWBD SWITCHBOARD VALVE IN VERTICAL PIPE VOLUME DAMPER (VD.) u� SECTION IDENTIFICATION SHEET NUMBER cKT aRCUIT SwGR Sw�TCHCEAR No Revisions Date ,�,� R CL CENTER LINE K DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, ' F AND T TRAP CAP LBS/HR � DETAIL NUMBER CLG CEILING KCMIL THOUSAND CIRCULAR MILS T �� DETAIL IDENTIFICATION SHEET NUMBER CLR CLEAR KV KILOVOLT T-1 TRUNK LEVEL 1 STRUCTURAL, shop and other appropnate drawmgs or at site Lay out and coordinate � PIPING CM COMMUNICATIONS CABLE KVA KILOVOLT AMPERE TBB TELECOMMUNICATIONS all work pnor to installation to provide clearances required for operation, maintenance, E CMP COMMUNICAl10NS PLENUM CABLE KW KILOWATT BONDING BACKBONE SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION � CMR COMMUNICATIONS RISER CABLE TBBIBC TELECOMMUNICATIONS BONDING and codes Verify non-interference with other work. DO NOT FABRICATE PRIOR TO CO CLEAN oUT �- BACK80NE INTERCONNECIING VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICATIONS � � �� �O ELBOW UP q— CONCENTRIC REDUCER COAX COAXIAL CABLE LAN LOCAL AREA NETWORK BONDING CONDUCTOR �} ELBOW �fl ELBOW DOWN ECCENTRIC REDUCER CU CONDENSING UNIT LBS POUNDS TDD TELECOMMUNICATIONS m COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby —���— U�JION ���� GLOBE VALVE F--�O PRESSURE GAUGE WITH GAUGE COCK CUH CABINET UNIT HEATER LTG LIGHTING DEVICE FOR THE DEAF granted solely for the limited purpose of construction of this pro�ect or for archiving ' CV CONSTANT VOLUME TELECOM TELECOMMUNICATIONS Unauthonzed copymg, disclosure or construction use without written permission of Alvine STRAINER WITH BLOW-OFF VALVE _�P T.T. PRESS / TEMP TEST PORT � THERMOMETER, SIDE FEED M TEL TELEPHONE Engineering is prohibited by copyright law. � BALANCING VALVE �� GATE VALVE � MA MAKE-UP AIR TEMP TEMPERATURE �� RROW WD CATES FLOW DER�EC110N DD DOUBLE DUCT MAN MASTER ANTENNA TELEVISION TGB TELECOMMUNICATIONS M EC HAN I CAL SYM BO LS AB B R EVIATI O N S� � ISOLATION VALVE (BALL OR BUTTERFLY) --���-- CHECK VALVE (ARROW INDICATES FLOW) � DF DRINKING FOUNTAIN MAX MAXIMUM GROUNDING BUSBAR ' � PRESSURE RELIEF VALVE `� FLEXIBLE PIPING " ARROW INDICATES DOWNWARD PIPE PITCH DIA DIAMETER MCB MAIN CIRCUIT BREAKER TMGB TELECOMMUNICAl10NS DETAILS AND SCHEDULES ' D FIRE PROTECTION _ oi� DIFFUSER MDF MAIN DISTRIBU110N FRAME I�AIN GROUNDING BUSBAR DISC DISCONNECT MECH MECHANICAL TR TELECOMMUNICATIONS ROOM ; SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYIuIBOL DESCRIPTION DIST DISTRIBUTION MH MANHOLE TS FIBER OPT1C TERMINATION SHELF F FIRE LINE HC FIRE HOSE CABINET DN DOWN MIN MINIMUM TU TERMINAL UNIT C 0 LO R A D 0 B A L L R 0 0 M � SM SPRINKLER MAIN FVC FIRE HOSE VALVE CABINET —.��_ OS AND Y VALVE DWG DRAWING MISC MISCELLANEOUS TUR TERMINAL UNIT REHEAT � MLO MAIN LUGS ONLY N TELEVISION R E N 0 VAT I 0 N � -0 SPRINKLER BRANCH AND HEADS � FH FIRE HYDRANT � ALARM CHECK VALVE E MM MULTIMODE TYP TYPICAL � —� SIAMESE CONNECTION ^� P�� POST INDICATOR VALVE --�-' FLOW SWITCH EA EXHAUST AIR MTD MOUNTED EF EXHAUST FAN MTG MOUNTING U VA I L, C 0 LO R A D 0 EL ELEVATION MUTOA MULII USER TELECOMMUNICAl10NS UG UNDERGROUND ELEC ELECTRICAL OUTLET ASSEMBLY UH UNIT HEATER i EMD ESTIMATED MAXIMUM DEMAND UL UNDERWRITERS LABORATORY VAIL COLORADO C - • EMI ELECIROMAGNETIC INTERFERENCE N UNO UNLESS NOTED OTHERWISE EMT ELECTRIC METAWC TUBING NC NORMALLY CLOSED UPS UNINTERUPIIBLE POWER SUPPLY EQUIP EQUIPMENT NEC NATIONAL ELECTRICAL CODE UR URINAL ' ER EQUIPMENT ROOM NIC NOT IN CONTRACT UTP UNSHIELDED TIMSTED PAIR EWC ELECTRIC WATER COOLER NO NORMALLY OPEN UV UNIT VENIILATOR ' EWH ELECTRIC WATER HEATER NOM NOMINAL EXH EXHAUST NTS NOT TO SCALE V EXIST EXISIING V VOLT � /y I ♦ I n e � VAV VARIABLE AIR VOLUME F OA OUTSIDE AIR VERT VERIICAI � FA FIRE ALARM OC ON CENTER VFD VARIABLE FREQUENCY DRIVE E n g i n e e r i n g , FAAP FIRE ALARM ANNUNCIATOR PANEL OSP OUTSIDE PLANT VTR VENT THROUGH ROOF B � FACP FIRE ALARM CONTROL PANEL Omaha �ncoln• Des Moines FB FLOOR BOX P �/ 1102 Douglas on the Mall 1800 0 Street,Suite 104 4308 Unrversity Avenue � FCU FAN COIL UNIT PB PULLBOX W WATT Omaha,Nebraska 68102 Lincoln,Nebraska 68508 Des Moines,lowa 50311 o, FD FLOOR DRAIN PBX PRIVATE BRANCH EXCHANGE WAN WIDE AREA NETWORK Phone (402)346-7007 Phone (402)477-6161 Phone (515)243-0569 ' = R FLOOR PERP PERPENDICULAR WAP WIRELESS ACCESS POINT Fox (402)346-9576 Fax (402)477-9616 � ' � ' FLA FULL LOAD AMPS PHC PREHEAT COIL WC WATER CLOSET r- Designed File Name T , FMG FACTORY MUTUAL GLOBAL PHVAC PLUMBING, HEAl1NG, VENIILATION WH WATER HEATER ^ ,y FO FIBER OPTIC AND AIR CONDI110NING WMP WIRE MANAGEMENT PANEL OO G BAH 2O069026M3 FP FIBER PANEL PIV POST INDICATOR VALVE WP WEATHER PROOF �eeo• • � ' FT FEET PLBG PLUMBING �; PNL PANEL X `�;� � •• c�` rawn ro�ect No. PP PATCH PANEL XFMR TRANSFORMER : RRW 20069026 o PRV PRESSURE REGULAl1NG VALVE � � m= PN � PSF POUNDS PER SQUARE FOOT Y � � Checked Drawing No. ^ - PSI POUNDS PER SQUARE INCH YH YARD HYDRANT � .d°��' STA �� PWR PO RNYL CHLORIDE �`ssOIVAL��` Date .D M 3 a � � qr l� 0��20��00� 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FLAG NOTES M 1� REMOVE EXISIING PANEL, RETAIN EXISTING FEEDERS FOR REUSE WITH NEW , PANEL. SEE RISER DIAGRAh4 FOR ADDITIONAL INFORMATION 2� REMOVE EXISTING PANEL, RETAIN EXISTING FEEDERS FOR REUSE WITH NEW DISCONNECT SEE RISER DIAGRAM FOR ADDITIONAL INFORMATION. 3� REMOVE EXISTING DIMMING SYSTEM AND LIGHTING CONTROL SYSTEM. REUSE _. EXISTING WIREWAY AND CONDUITS FOR LIGHTING BRANCH CIRCUITS WHERE POSSIBLE 4� EXISTING CEILING TO BE REPLACED, REMOVE EXISIING LIGHTING AND CEILING DEVICES INCLUDING BUT NOT LIMITED TO SPEAKERS AND FIRE ALARM DEVICES � RETAIN SPEAKERS AND ASSOCIATED WIRING FOR REUSE IN NEW CEILING L COORDINATE WITH OWNER FOR REMOVAL OF ABANDONED LOW VOLTAGE WIRING. RETAIN LIGHIING CIRCUITS AND CONDUITS FOR REUSE WITH NEW SYSTEM WHERE POSSIBLE. 5� EXISTING WALL DEVICES EXCEPT FIRE ALARM AND LIGHTING CONTROL DEVICES TO REMAIN UNLESS OTHERWISE NOTED 6� REMOVE EXISIING FIRE ALARM AND LIGHIING CONTROL DEVICES COORDINATE REMOVAL WTH GENERAL CONTRACTOR FOR LOCATIONS NEEDING CUT AND � u � , PATCHED � , � RETAIN EXISTING EXIT SIGNS FOR REUSE WITH NEW WORK K � � , ' EXISTING PLANTER DN EXISTING WALKWAY � � J LIMIT OF CONSTRUCTION - - - - - - - - - - - - - - - o � � � � — - - - - - — , o I BEAUTY SALON 7 7 7 7 I N I.0 I � � , � EN' BEAUTY I SALON I NIC I PROPOSED FUTURE RESTROOM LOCATIONS H I ° � � � N I � � �WOME�N S� STAIR UP CO O ADO � � >,H„ _ I � U`J"' � OUNT IN VIEW G ' 4 0 L i F' I STORE I ` � � CBRBH , � 3 DIMMING CABINETS 4 5 6 SERVI CORRIDOR , �LIGHTING � No Revisions Date � CONTROL PANEL � DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, � � STRUCTURAL, shop and other appropnate drawings or at site. Lay out and coordinate SERVICE CORRIDOR all work pnor to installation to provide clearances required for operation, maintenance, E N I C and codes Verify non—interference with other work DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICAl10NS � � � COPYRIGHT 2007 Permission to reproduce all or part of this Drawmg is hereby , _ granted solely for the limited purpose of construction of this project or for archivmg Unauthonzed copying, disclosure or construction use without written permission of Alvine . Engineenng is prohibited by copynght law ; ; , _ - ELECTRICAL ; D _ DEMOLITION , ' COLORADO BALLROOM RENOVATION �, FLOOR PLAN — DEMOLITION VAIL, COLORADO SCALE: 1/8"=1 '-0" VAIL COLORADO , C � ' Alvine � Engineering ' Omaha Lincoln Des Moines B � 1102 Douglas on the Mall 1800 0 Street,Swte 104 4308 Unrversiiy Avenue , Omaha,Nebraska 68102 Lincoln,Nebraska 68508 Des Moines,lowa 50311 Phone (402)346-7007 Phone (402)477-6161 Phone (515)243-0569 ; ' � Fax (402)3 6-9576 Fax (402)477-9616 � Designed File Name ' N � �p � . �',o RRS 20069026E1 1 , O eae�oo a fSr� ��� � o�, �� ef <�, .� wn ro�ec No. a o q � � � RRS 20069026 o A ' , o m� � Checked N �0167 �� ! Drawing No f� �� m�� °�, TJT � � � o��O°000000�°oo\�� � ,�� - - `��'�ONAL���' Date � � ( �'� 0�/2o/zoo� � 2 3 4 5 6 7 8 9 10 11 12 13 14 � � 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FLAG NOTES ` M 1� MOUNT (5) EPC'S (EMERGENCY POWER CONTROL UNITS) ON WALL IN DIMMER �` ROOM UTILIZE 4 11/16" SQUARE BOXES WITH 1/2" SINGLE GANG PLASTER RINGS � PROVIDE ITE 20/1 BREAKERS FOR EACH EMERGENCY CIRCU�T AT PANEL 'EMB' - 3� INSTALL CHANDEI.IER FURNISHED BY MARRIOTT. j 4� CONNECT EXIT SIGNS AHEAD OF LOCAL SWITCHES, TO NEAREST EMERGENCY � L CIRCUIT. 5� PROVIDE DEDICATED NEUTRALS FOR DIM�IING CIRCUITS. 6� TIE NEW LIGHTS IN PRE-FUNCTION SPACE INTO EXISTING BRANCH CIRCUITING � AND CONTROLS � REUSE EXISTING EXIT SIGNS � APPROXIMATE LOCATION OF HANG POINT (BY OTHERS) 9 COORDINATE FINAL MOUNTING HEIGHT WITH ARCHITECT K 10 PROVIDE ETC UNISON CONTROL INTERFACE (UCI) TO ALLOW ILLUMINATION TO RESTORE UPON ACTIVATION OF FIRE ALARM PROVIDE FIRE ALARM CONTROL � Q1 MODULE, CABLING FROM UCI TO FIRE ALARM CONTROL PANEL, AND CONNECTIONS AS REQUIRED. 11 PROVIDE FIRE ALARM CONTROL MODULE FOR ACTIVAl10N OF SHUNT TRIP BREAKER TO SOUIvD SYSTEM, PROVIDE ALL NECESSARY CABLING FOR FIRE ' EXISTING PLANTER oN ALARM CONTROL MODULE EXISTING WALKWAY � � J IMIT OF CONSTRUC110N 9 EMB I 9 EXISTING EXISTING EGRESS DOORS 7 EGRESS DOORS - � W TO REMAIN W TO REMAIN — — — — —S— � � — — — — —� �TYP) 4 $LV5 — — — — — — — S F$ - i ° I Q F $LV5 DRCB-15 F E�V5 F1 F1 F1 B ALON . F F F F g� F F F F F � 75CD � N I C I ° DRCB-16,23 • 6 5 (TYP) F1 F1 Ft F — F F F F F F F 110CD 8 � TYP F " ,� F g 1-�D I �- BSALONY 8 1. BUILDIiVG FIRE ALARM SYSTEM SHALL REMAIN AND F � F F I NIC F F �� F F F F F � MEN'S CONTINUE OPERATION DURING ENTIRE CONSTRUCTION S I � PERIOD EXPAND AS REQUIRED TO ACCOMODATE NEW ROPOSED FUTURE RESTROOM H I o � � � � LOCATIONS DEVICES. F � � F F F F F � F I N F F S CtOf 1 ��� 3 I �- � � � UP STAIR E� F F F F F F F F F F � WOMEN'S „H„ �' � ��M �' - �- I - -p- - F DRCB-1,3,4 � � ° MOUNTAIN VIEW 11 CD F F F 110CD F F C1 F F '�' F �� F F F F BOARD ROOM , � 5CD � � � _ _ � 110CD� � LJ F I � F F , . F F F F F DCl F F F � F �� '� s �6— DRCB-7,9,10 s 2 F F F F 'EMB� ' � DRCB-1 3,14 � F F � DRCB-17,19,20 C1 C1 C1 C1 ' C1 C1 C1 C1 C1 C1 � � F F F DRCB-11 F F I STORE j * $LV1 F3 F3 F3 F3 F3 �LV10�7 I � S V10 7 g S S _ � �� _ DRCB-8 CBRBH DRCB-18,21 RCB DRCB-2,5 » F �M Mg SERVICE CORRIDOR Qj TOWN OF VAIL COMMENTS 08/31/07 � " No Revisions Date AIR WALL IDENTIFIER DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, 1 STRUCTURAL, shop and other appropriate drawings or at site. Lay out and coordinate 1 SERVICE CORRIDOR all work pnor to installation to provide clearances required for operation, maintenance, E 10 N I C a and codes Verify non-interference with other work. DO NOT FABRICATE PRIOR TO � VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICATIONS ' - m COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby ' � - granted solely for the limited purpose of construction of this project or for archiving - Unauthonzed copying, disclosure or construction use without written permission of Alwne � Engmeenng is prohibited by copyright law. ^ LIGHTING FIXTURE SCHEDULE � , z - � ECTRICAL D � N�� MANUFACTURER CATALOG NO (NOTE 1) LAMP DATA VOLTS MOUNIING DESCRIPTION RE�,ARKS . LI G HTI N G QUANTITY AND SIZE TYPE C LIGHTOLIER 6000 SERIES - - 120 SURFACE-GRID TRACK NOTE 2,5 C 0 LO R A D 0 B A L L R 0 0 M C1 LIGHTOLIER 22SS8WH-AL4HC/LOUVER Q90PAR38/NFL-28 I 120 TRACK TRACK SPOT NOTE 4 R E N OVAT I 0 N TO BE SPECIFIED BY 6' DIAMETER � VA I L C 0 LO RA D 0 DC-1 INTERIOR DESIGNER - 1000W I 120 CEILING CHANDELIER f DC-2 TO BE SPECIFIED BY _ 1000W I 120 CEILING 4' DIAMETER - VAIL COLORADO C INTERIOR DESIGNER CHANDELIER E1 LITHONIA LQM-SW1G-120/277 FURNISHED W/ FIXTURE LED 277� UNIVERSAL EXIT SIGN � i F LIGHTOLIER 8039CLP-8242HCU3 (2) CF42DT/E/IN/830 CF 120 RECESSED-GRID „DIMMABLE NOTE 3 F LO 0 R P LA N — L I G H T I N G 8 DOWNLIGHT � F1 LIGHT�LIER 8037CLP-71266U CF26DT/E/IN/830 CF 120 RECESSED-GRID „DIMMABLE NOTE 3 � r SCALE: ') $��=') �—O�� 8 DOWNLIGHT / A I v i n e F3 LIGHTOLIER 8087CLP-7142BU CF42DT/E/IN/830 CF 120 RECESSED-GRID yyW DOWNLIGHT NOTE 3 � o TO BE SPECIFIED BY E n g � n e e r a n g B S INTERIOR DESIGNER - 80W I 120 WALL WALL SCONCE - Omaha� Lincoln� Des Moines• 1102 Douglas on the Mall 1800 0 Street,Swte 104 4308 Unrversity Avenue Wl LITHONIA WST-2/32TRT-WT-120 (2) 32W TRT 3500K F 120 WALL EXTERIOR NOTE 5,6 � Omaha,Nebraska 68102 Lincoln,Nebraska 68508 Des Moines,lowa 50311 EMERGENCY INSTALL GREEN INSULATED Phone (402)346-7007 Phone (402)477-6161 Phone (515)243-0569 ' � NOTES GROUND WIRE WITH ALL Fax (402 346-9576 Fax (402)477-9616 LIGHTING, RECEPTACLE AND Designed File Name � EQUIPMENT BRANCH CIRCUITS � ^ 0 1. CONTRACTOR TO VERIFY LIGHT FIXTURE CATALOG NUMBER AND INSTALLATION REQUIREMENTS PRIOR TO ORDERING 9 E RRS 20069026E2.1 �' Q.P, .. o. ! 2 CONFlRM EXACT LENGTHS REQUIRED AND PROVIDE ALL NECESSARY PARTS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLAl10N. � vp � S R. � rawn ro�ec o. N 3 PROVIDE ADVANCED MARK 10 DIMMING BALLAST(S). ' ��� 20167 �s RRS 20069026 o A 4 PROVIDE NUMBER OF HEADS INDICATED ON PLANS. � Checked Drawing No � 5 CONFIRM COLOR WITH ARCHITECT PRIOR TO ORDERING � _ �4 ^ s�°bsot�dM°�\�� TJT '� 6. PROVIDE COLD WEATHER BALLASTS AND PHOTOELECTRIC CELL PER FIXTURE s�ONAIE� Date E — � • 1 1 Q - U'1 1`� �1 0��20�200� 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FLAG NOTES , M 1� REMOVE EXISIING DIMMING ROOM PANEL, RETAIN EXISTING FEEDERS FOR REUSE �, WITH NEW DISCONNECT. LOA D S U M M A RY EAST W I N G � REMOVE EXISIING PANEL 'CBRBH', RETAIN EXISTING FEEDERS AND BRANCH CIRCUITS FOR REUSE WITH NEW PANEL BOARD � PROVIDE NEW PANEL IDENTIFICATION FOR PANEL 'CBRBH'. EXISIING SYSTEM 2000A, 208Y/120V, 3–PHASE 4� PROVIDE HUBBELL 4 POLE, 5 WIRE RECEPTACLE CATALOG # HBL26520 PROVIDE • MANUFACTURER RECOMMENDED BACK BOX AND ADAPTER PLATE. ` ' PEAK LOAD FOR LAST YEAR (JAN 07'): 250 KW � PEAK LOAD INCLUDING POWER FACTOR (85�)• 294 KVA 5� COORDINATE FINAL LOCATION OF RECEPTACLES WITH OWNER PRIOR TO ' L � , PEAK LOAD INCLUDING DEMAND FACTOR (125%) 367 KVA INSTALLAl10N 6� RETERMINATE EXISTING BRANCH CIRCUfTING IN NEW PANEL � ADDITIONAL LOADS. � � , 1) PANEL CBRBH 15 KVA (NEW RECEPTACLES) 7� APPROXIMATE LOCATION OF HANG POINT (BY OTHERS) ° 2) PANEL LPD NO ADDITIONAL LOAD g� MOUNT RECEPTACLES AT BOTTOM OF DECK NEAR HANG POINTS. PROVIDE TOTAL EAST WING LOAD• 382 KVA PRICING UNDER ALTERNATE #1 106215 AMPS � PROVIDE J–BOX MOUNTED TO DECK FOR DATA OUTLET. CABLE AND FACEPLATE ` 10 PROVIDE SHUNT TRIP BREAKER FOR POWER SUPPLY TO SOUND SYSTEM PROVIDE CONTROL WIRING TO FIRE ALARM CONTROL MODULE TO SHUT DOWN SOUND K a SYSTEM UPON FIRE ALARM ACTIVATION � � , � , EXISTING PLANTER �N � ❑ --.-- ❑ EXISTING WALKWAY J IMIT OF CONSTRUCTION ; EXISTING EXISTING EGRESS DOC�RS EGRESS DOORS TO REMAIN TO REMAIN � o I � BEAUTY I (�P) SALON � NIC I o � 7 � � � I I — � �, ALTERNATE #1 PROVIDE RECEPTACLES, ASSOCIATED BRANCH CIRCUITING, BEAUTY AND J—BOXES FOR HANG POINTS � I � SALON NIC I � MEN'S � I � PROPOSED FUTURE RESTROOM I H I I p� o � � � � LOCATIQNS , Lti� i N � (TYP) , �nP, D � , � � � � � -�- STAIR UP I � WOMEN�S "H" � CO RADO _ �_ _ BA aM — �- — I CBRBH-2,4,6 � � � � MOUNTAIN VIEW I � BOARD ROOM � G I CBRBH-8,10 � � r � . ; � � � _ 0 � CBRBH� �� CBRBH-7 . 'EMB' I (4#6, 1#10 GND. IN 1 C) (4#6, 1#10 GND IN 1"C) CBRBH-13 , (60/3) (60/3) (60631#10 GND. IN 1"C) I 5 � � ) F I �nP� 4 I STORE � � �T�) � CUSTOM WALL — STATUS ANNUCIATION PANEL DRCB CBRBH � 1 SERVICE CO IDOR Q TOWN OF VAIL COMMENTS 8/31/07 � �o , s No Revisions Date DO NOT SCALE DRAWINGS VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, � � STRUCTURAL, shop and other appropriate drawings or at site. Lay out and coordmate , SERVICE CORRIDOR all work prior to installation to provide clearances required for cperation, mamtenance, E N.I.0 and codes Verify non–interference with other work DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICAl10NS ' m COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby � granted solely for the limited purpose of construction of this project or for archiving - Unauthorized copying, disclosure or construction use without written permission of Alwne EW 100A, 3 POLE NON–FUSIBLE DISCONNECT Engineenng is prohibited by copynght law. EXIS�ING FEEDER EXISTING FEEDER ELECTRICAL ; � D � � INSTALL GREEN INSULATED POWER ' GROUND WIRE WITH ALL , 7�3 LIGHTING, RECEPTACLE AND C 0 LO R A D 0 �A L L R 0 0 M � 2 PANEL — � EQUIPMENT BRANCH CIRCUITS , CBRBH FL00 R P LAN — POWE R RENOVATION NEW DIMMING RACK 'DRCB' SCALE: 'I�H��='I �—O�� VAI L, COLORADO i � XISTING PANEL 'CBRBH' EXISTING EXISTING DIMMING PANEL (4#4, 1#8 GND., IN 1-1/4"C) VAIL COLORADO C PANEL 'LPD' ; � ' ' COLORADO BALLROOM LEVEL 0 ; EXISTING DISTRIBUTION o � PANELCDP-6 � LIGHTING PANEL SCHEDULE Alvine � v � a PANEL CIRCUIT QUANTITY AND SIZE BRANCHES • • i � 4 DESIGNATION NUMBERS ACTIVE SPARE SPACE REMARKS E n g � n e e r � n g ' B 150/3 CBRBH 1 -42 11 20�1 22 20�1 0 Omaha Lincoln Des Moines� � 1102 Dougias on the Mall 1800 0 Street,Suite 104 4308 Unrversity Avenue 3 — 208�120V 3 PH, 4 W 3 60�3 Omaha,Nebraska 68102 Lincoln,Nebraska 68508 Des Moines,lowa 50311 ' 150A MLO Phone (402)346-7007 Phane (402)477-6161 Phone (515)243-0569 � � , � W/ GND BAR Fax (402) 46-9576 Fax (402)477-9616 � � FLUSH MOUNTED Designed File Name � BASEMENT LEVEL 42 POLES � � � " o OQ ��1; ' RRS 20069026E3.1 ! � ST = SHUNT TRIP �,��,� °�p,S if ° ���� rawn ro�ec No. 1 � G = GROUND FAULT CURRENTINTERRUPTER o � �m RRS 20069026 ro A COLORADO BALLROOM PARTIAL ELECTRICAL RISER �o �01�7 mo� Checked Drawing No. o � ,� NO SCALE " � �Sio�up�E����� Date TJT � .� E - 3 . � ,� l�`� 0��20�200� ' 1 2 3 4 5 6 ' 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 � FLAG NOTES � � M o � ' N ELECTRICAL SYMBOLS ABBREVIATIONS � 0 W LIGHTING AND POWER A G R W SYMBOL DESCRIPTION SYMBOL DESCRIP110N SYMBOL DESCRIP�ION A AMP GA GAGE RA RETURN AIR FLUORESCENT FIXTURE BRACKET FIXTURE EMERGENCY BATTERY LIGHT AC ALTERNAl1NG CURRENT GALV GALVANIZED RD ROOF DRAIN � # INDICATES FIXTURE NUMBER IN SCHEDULE � # INDICATES FIXTURE NUMBER IN SCHEDULE � # INDICATES FIXTURE NUMBER IN SCHEDULE AA FG A OVEUFlNISHED F OOR GEN GENERATOR ELECTRODE CONDUCTOR RE A RELIIEF�AIR SHADING INDICATES FIXTURE ON EMERGENCY TRACK MOUNTED FIXTURE POLE LUMINAIRE(S) APPROX APPROXIMATELY GFl GROUND FAULT INTERRUPTER REQD REQUIRED � CIRCUIT OR WITH BATTERY PACK �# INDICATES FIXTURE NUMBER IN SCHEDULE °� ATS AUTOMATIC TRANSFER SWITCH GND GROUND RF RETURN FAN t # # INDICATES FIXTURE NUMBER IN SCHEDULE ATU AIR TERMINAL UNIT GPM GALLONS PER MINUTE RGS RIGID GALVANIZED STEEL L �� FLUORESCENT STRIP LIGHT AUX AUXIUARY RH ROOF HOOD CEILING MOUNTED EXIT LIGHT BOLLARD LUI�INAIRE # INDICATES FIXTURE NUMBER IN SCHEDULE �# WITH DIRECTIONAL ARROW � # INDICATES FIXTURE NUMBER IN SCHEDULE A/V AUDIO/VISUAL H RHC REHEAT COIL BRACKET FLUORESCENT FIXTURE # INDICATES FIXTURE NUMBER IN SCHEDULE AVG AVERAGE HB HOSE BIBB RM ROOM � CEILING FAN — NUMBER OF BLADES IS IN SCHEDULE AWG AMERICAN WIRE GAUGE HC HEATING COIL RTU ROOFTOP UNIT # INDICATES FIXTURE NUMBER IN SCHEDULE WALL OR END MOUNTED EXIT LIGHT # INDICATES FIXTURE NUMBER IN SCHEDULE HGT HEIGHT B HP HORSE POWER S � CEILING FIXTURE �# WITH DIRECTIONAL ARROW BICSI BUILDING INDUSTRY CONSULIING HTG HEAl1NG SA SUPPLY AIR # INDICATES FIXTURE NUMBER IN SCHEDULE # INDICATES FIXTURE NUMBER IN SCHEDULE SERVICES INTERNAl10NAL HTR HEATER SAN SANITARY S SINGLE POLE SWITCH Sp DOOR SWITCH BLDG BUILDING HVAC HEATING, VEN11LAl1NG SCH SCHEDULE MANUAL DIMMER OR FAN SPEED CONTROL BTU BRIIISH THERMAL UNIT AND AIR CONDITIONING SF SUPPLY FAN ' S2 DOUBLE POLE SWITCH SMC MOMENTARY CONTACT SWITCH � (# INDICATES WAITAGE "6"-600W. °10"-1000W, C HZ HERTZ SM SI K�R � S3 3 - WAY SWITCH QQ CEILING MOUNTED MOTION SENSOR/SWITCH "15"-1500W, "20"-2000W, "F"-FAN SPEED CONTROL) C CONDUIT I SM SINGLE MODE S4 4 - WAY SWITCH i-Q WALL MOUNTED MOT10N SENSOR/SWI fCH CAB CABINET IC INTERCOM SP SUMP PUMP � DUPLEX RECEPTACLE � CEILING MOUNTED DUPLEX RECEPTACLE �yy WELDER RECEPTACLE NEMA 6-50 (250V 50A) CAN CABLE TELEVISION IDF INTERMEDIATE DISTRIBU110N FRAME SPEC(S) SPECIFICAl10NS �� DUPLEX RECEPTACLE - GFCI TYPE O FLOOR DUPLEX RECEPTACLE � SPECIAL PURPOSE RECEPTACLE CB CIRCUIT BREAKER IN INCH SS SERVICE SINK CC COOLING COIL ISP INSIDE PLANT STD STANDARD �� ISOLATED GROUND DUPLEX RECEPTACLE �� ISOLATED GROUND DOUBLE DUPLEX RECEPTACLE (NEMA CONFIGURE AS NOTED) CCN CLOSED CIRCUIT TELEVISION STP SHIELD T1MST PAIR � HIGH ABUSE DUPLEX RECEPTACLE � DOUBLE DUPLEX RECEPTACLE � HORIZONTAL MOUNTED DUPLEX RECEPTACLE � CFM CUBIC FEET PER MINUTE J SW SWITCH , �S SAFETY TYPE DUPLEX RECEPTACLE � SINGLE RECEPTACLE � MULTI-OUTLET ASSEMBLY - LENGTH AS INDICATED CH CHILLER JB JUNCTION BOX SWBD SWITCHBOARD CKT CIRCUIT SWGR SWITCHGEAR � RED DUPLEX RECEPTACLE b DRYER RECEPTACLE NEMA 14-30 (125/250V 30A) �� CORD AND PLUG CL CENTER LINE K � DUPLEX RECEPTACLE - SPLIT WIRED � RANGE RECEPTACLE NEMA 14-50 (125/250V 50A) i-OO PHOTOCELL CLG CEILING KCMIL THOUSAND CIRCULAR MILS T J CLR CLEAR KV KILOVOLT T-1 TRUNK LEVEL 1 i-�Q WALL MOUNTED JUNCTION BOX JUNCTION BOX CM COMMUNICAl10NS CABLE KVA KILOVOLT AMPERE TBB TELECOMMUNICAl10NS �# (°F" INDICATES FLOOR, "C" INDICATES CEILING) CMP COMMUNICAl10NS PLENUM CABLE KW KILOWATT BONDING BACKBONE � LIGHTING PANEL BRANCH CIRCUIT - EXPOSED �� SPECIAL PURPOSE HOMERUN AS INDICATED CMR COMMUNICATIONS RISER CABLE TBBIBC TELECOMMUNICAl10NS BONDING � CO CLEAN OUT L BACKBONE INTERCONNECIING ' -- EXISTING LIGHTING PANEL �� BRANCH CIRCUIT CONCEALED IN CEILING OR WALL �� CONDUIT SEAL COAX COAXIAL CABLE LAN LOCAL AREA NETWORK BONDING CONDUCTOR DISTRIBUTION PANEL, SWITCHBOARD OR BRANCH CIRCUIT CONCEALED IN FLOOR ��. CIRCUIT DOWN CU CONDENSING UNIT LBS POUNDS TDD TELECOMMUNICA�IONS � �-� CUH CABINET UNIT HEATER LTG LIGHIING DEVICE FOR THE DEAF MOTOR CONTROL CENTER (UNDERGROUND IF EXTERIOR) �--� CIRCUIT UP CV CONSTANT VOLUME TELECOM TELECOMMUNICATIONS �� HOMERUN TO PANEL (NUMBER OF ARROWS ��� CONDUIT STUB-OUT p M TEL TELEPHONE INDICATES NUMBER OF CIRCUITS MA MAKE—UP AIR TEMP TEMPERATURE � �� CIRCUIT BREAK DD DOUBLE DUCT MAN MASTER ANTENNA TELEVISION TGB TELECOMMUNICAl10NS OO MOTOR - HORSEPOWER AS INDICATED � SWITCH AND FUSE � SINGLE PHASE MAGNETIC MOTOR STARTER DF DRINKING FOUNTAIN MAX MAXIMUM GROUNDING BUSBAR � SAFETY SWITCH � SWITCH AND FUSTAT � 1NREE PHASE MAGNETIC MOTOR STARTER DIA DIAMETER MCB MAIN CIRCUIT BREAKER TMGB 1ELECOMMUNICATIONS ' � (FUSED UNLESS OTHERWISE NOTED) DIFF DIFFUSER MDF MAIN DISTRIBUTION FRAME MAIN GROUNDING BUSBAR ; � ENCLOSED CIRCUIT BREAKER �--' COMBINATION MAGNETIC STARTER/DISCONNECT DISC DISCONNECT MECH MECHANICAL TR TELECOMMUNICATIONS ROOM '� SINGLE POLE MANUAL MOTOR STARTER WITH � RELAY 0 MOTOR CONTROL PUSH-BUTTON STATION DIST DISTRIBUTION MH MANHOLE TS FIBER OPTIC TERMINATION SHELF S'� THERMAL OVERLOAD AND PILOT LIGHT � LIGHTING CONTACTOR DWG DRAWING MI C MISCELLANEOUS TUR TERMINAL UNIT REHEAT FIRE DETECTION MLO MAIN LUGS ONLY TV TELEVISION SYMBOL DESCRIPTION SYMBOL DESCRIP110N SYMBOL DESCRIPTION E MM MULIIMODE TYP TYPICAL EA EXHAUST AIR MTD MOUNTED � FIRE ALARM AUTOMATIC SMOKE DETECTOR � FIRE SPRINKLER FLOW SWITCH � CEILING FIRE ALARM SPEAKER EF EXHAUST FAN MTG MOUNTING U FIRE ALARM AUTOMATIC SMOKE DETECTOR � FIRE ALARM HORN AND LIGHT COMBINATION i-O WALL FIRE ALARM SPEAKER EL ELEVAl10N MUTOA MULII USER TELECOMMUNICAl10NS UG UNDERGROUND �� WITH SOUNDER BASE - E�EC ELECTRICAL OUTLET ASSEMBLY UH UNIT HEATER I..I � FIRE ALARM MINI—HORN � CEILING FIRE ALARM SPEAKER EMD ESTIMATED MAXIMUM DEMAND UL UNDERWRITERS LABORATORY � FIRE ALARM AUTOMATIC HEAT DETECTOR AND LIGHT COMBINA110N AND LIGHT COMBINATION EMI ELECTROMAGNEIIC INTERFERENCE N UNO UNLESS NOTED OTHERIMSE , �-- SAMPLING TUBE TYPE SMOKE DETECTOR EMT ELECTRIC METAWC TUBING NC NORMALLY CLOSED UPS UNINTERUPTIBLE POWER SUPPLY ' CEILING FIRE ALARM HORN WALL FlRE ALARM SPEAKER � �� EQUIP EQUIPMENT NEC NAl10NAL ELECTRICAL CODE UR URINAL ❑F FIRE ALARM MANUAL STATION AND LIGHT COMBINATION AND LIGHT COMBINATION ER EQUIPMENT ROOM NIC NOT IN CONTRACT UTP UNSHIELDED TWISTED PAIR ❑F �� FIRE ALARM CONTROL MODULE CEILING FIRE ALARM MINI-HORN � FIRE ALARM BELL AND LIGHT COMBINATION EWC ELECTRIC WATER COOLER NO NORMALLY OPEN UV UNIT VENTILATOR 0 MM FIRE ALARM MONITOR MODULE � AND LIGHT COMBINATION r■ FIRE ALARM MAGNEIIC DOOR HOLDER EWH ELECTRIC WATER HEATER NOM NOMINAL EXH EXHAUST NTS NOT TO SCALE V 0-$ FIRE SPRINKLER VALVE TAMPER SWITCH OO CEILING FIRE ALARM LIGHT � COMBINATION FIRE/SMOKE DAMPER EXIST EXISIING V VOLT � FIRE ALARM CONTROL PANEL i-OO WALL FIRE ALARM LIGHT --� SMOKE DAMPER � VAV VARIABLE AIR VOLUME F OA OUTSIDE AIR VERT VERIICAL ' � FIRE ALARM ANNUNCIATION PANEL / F FIRE FIGHTER'S TELEPHONE JACK � � FA FIRE ALARM OC ON CENTER VFD VARIABLE FREQUENCY DRIVE G SUBSCRIPTS FAAP FIRE ALARM ANNUNCIATOR PANEL OSP OUTSIDE PLANT VTR VENT THROUGH ROOF � FACP FIRE ALARM CONTROL PANEL SYIuIBOL DESCRIPTION SYMBOL DESCRIP110N SYMBOL DESCRIPTION FB FLOOR BOX P W ^ SUBSCRIPT "EP" APPLIED TO ANY SYMBOL SUBSCRIPT "WP" APPLIED TO ANY SYMBOL SUBSCRIPT "RT" APPLIEQ TO ANY SYMBOL FCU FAN COIL UNIT PB PULLBOX W WATT FD FLOOR DRAIN PBX PRIVATE BRANCH EXCHANGE WAN WIDE AREA NETWORK � EP INDICATES EXPLOSION PROOF, � INDICATES WEATHERPROOF NEMA TYPE 4 RT INDICATES RAIN TIGHT NEMA 3R FL FLOOR PERP PERPENDICULAR WAP WIRELESS ACCESS POIN i "� CLASS, GROUP AND DIVISION AS NOTED OR EQUIVALENT OR EQUIVALENT FLA FULL LOAD AMPS PHC PREHEAT COIL WC WATER CLOSET SUBSCRIPT "PD" ADDED TO ANY FLOOR OUTLET SUBSCRIPT "E" ADDED TO ANY SYMBOL SUBSCRIPT "K" ADDED TO ANY SYMBOL FMG FACTORY MUTUAL GLOBAL PHVAC PLUMBING, HEATING, VEN11LAllON WH WATER HEATER P� INDICATES PEDESTAL MOUNTED E INDICATES EXISTING K INDICATES KEY OPERATED FP FIBER PANEL PIV POSTpI D CANOR�VANVE WPP 1NEATH RNPROOFNT PANEL SUBSCRIPT "P" ADDED TO ANY SYMBOL SUBSCRIPT "WG" ADDED TO ANY SYMBOL FT FEET PLBG PLUMBING P INDICATES PILOT LIGHT W� INDICATES WIRE GUARD PNL PANEL X F PP PATCH PANEL XFMR TRANSFORMER � PRV PRESSURE REGULAl1NG VALVE , PSF POUNDS PER SQUARE FOOT Y PSI POUNDS PER SQUARE INCH YH YARD HYDRANT PVC POLYVINYL CHLORIDE . - PWR POWER ' � GENERAL NOTES No Revisions Date DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS and clearances from ARCHITECTURAL, � 1• MINIMUM SIZE FOR BRANCH CIRCUIT CONDUITS SHALL BE 3/4" MINIMUM STRUCTURAL, shop and other appropnate drawings or at site. Lay out and coordinate E , DATA/COMMUNICATIONS CONDUIT SIZE SHALL BE 1 " SEE DRAWINGS FOR all work prior to installation to provide clearances required for operation, mamtenance, , • AREAS WHERE LARGER CONDUITS ARE REQUIRED. and codes Verify non-interference with other work. DO NOT FABRICATE PRIOR TO VERIFICATION OF CLEARANCE FOR ALL TRADES READ SPECIFICAl10NS m COPYRIGHT 2007 Permission to reproduce all or part of this Drawing is hereby � � UEMOLITION NOTES granted solely for the limited purpose of construction of this project or for archiving � _ Unauthorized copying, disclosure or construction use without written permission of Alvine , 1. THE OWNER SHALL HAVE FIRST SALVAGE RIGHTS TO ALL FIXTURES, DEVICES Engmeenng is prohibited by copynght law. � AND EQUIPMENT REMOVED ' 2 WHERE EXISIING CIRCUITS ARE NOT REUSED, REMOVE CONDUCTORS AND E LECTR i CAL SYM BO L LEG E N D ' ASSOCIATED ACCESSIBLE RACEWAYS BACK TO 11-IE SOURCE ABANDON AB B R EVIATI O N S, AN D G E N E RAL N OTES D � CONCEALED CONDUITS IN WALLS WHICH ARE tJOT REMOVED ; � ' 3 SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL ELECTRICAL DEMOLITION ITEMS. C 0 LO R A D 0 �A L LR 0 0 M ; DISCONNECT AND REMOVE ELECTRICAL DEVICES, EQUIPMENT AND ASSOCIAIED , WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. R E N 0 VAT I 0 N 4. POWER TO EXISTING AREAS NOT BEING REMODELED SHALL BE MAINTAINED AT ' ALL 11MES EXCEPT FOR SHORT TERM OUTAGES NECESSARY FOR RECONNEC110N VA I L C 0 LO RA D 0 , � OF EXISIING CIRCUITS COORDINATE AND SCHEDULE OUTAGES WITH THE 7 I , � OWNER. VAIL COLORADO ' 5 COORDINATE DEMOLITION WITH THE WORK OF OTHER TRADES PROVIDE C � - � ` ` TEMPORARY POWER AS REQUIRED TO ALLOW THE WORK OF OTHER TRADES TO ; � PROCEED OR AS REQUIRED TO ALLOW THE OWNER TO OCCUPY THE SPACE � ' 6 REMOVE EXISTING FIRE ALARM DEVICES AND WIRING REUSE CONDUIT AND ` BOXES WHERE POSSIBLE FOR INSTALLATION OF NEW FIRE ALARM SYSTEM SEE I PROJECT MANUAL AND NEW WORK DRAWINGS � 7 THIN LINE ITEMS INDICATE EXISTING BOLD LINE ITEMS INDICATE NEW WORK A I � i n e � , , � , � , Engineering BOmaha Lmcoln Des Moines 1102 Douglas on the Mall 1800 0 Street,Suite 104 4308 University Avenue 4 Omaha,Nebroska 68102 Lincoln,Nebroska 68508 Des Moines,lowa 50311 � ;, Phone (402)346-7007 Phone (402)477-6161 Phone (515)243-0569 - � fax (402)3 -9576 Fax (402)477-9616 �' � Designed File Name ' � `° � RRS 20069026E4.1 , N � 0 . F.P,..o. ! . �' �S rawn ro�ec No � on 0 `° ° RRS 20069026 N o : " A g � � m: Checked �N o rawing No �; p ev ve•�t`�/� TJT E � - -fs 1 � �� `r`r�IVAL•��'\� v'� Date , � /, �, �"l 07/20/2�07 � ; 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14 FLAG NOTES � . �__...� P a.nel: DR�B ____ _�___._� � M ETC I)immi Panel Schedule j 1�01�08VA�, 3 Phase, 5 V4�ire�� � � � , � Z25A Main L s DIl�� LUG Control Room Load Fia►ture Fixt Phase # # Ton� # Descri tion e e �uan V�/f a�t A B C 1 1 1 1 Chand�li�r b� 4wner IN� DC2 � 1000 ��D�tl � � 2 2 1 Scance b �wn�ver IN� S 7 80 5b0 3 '7 3 1 Dav�nlight Center DFL F 8 S4 ��'�,','�"` � � �72 4 8 � 1 Downli t General DFL F 21 84 , 17�4 - � 5 13 � 1 Do�mli ht Sta e DFL F 4 84 . � 3 3� 6 14 6 1 Track Sta e IN� C1 4 90 , � = 3�0 7 19 1 2 Cha�nd�lier b O�vner INe DCl 2 1000 200� � K 8 �0 � 2 Scance b �wnvver INC S 2 80 160 ' � � 9 3 3 2 Dawnli ht �enter DFL F 8 84 � � �7� , , , �. � � 2 Downl' e 10 A� i t Gen ra.� DFL F 18 84 1512 11 9 � 2 Downli fi Sta e DFL F+F3 7 S 4 5 8$ � 12 1� G � Tracl� Sta � INC C 1 � 90 --- 5 4� � l� 1 � 7 2 Track Ri t IN� �1 3 90 Z'�0 � �� ' �� �� � 1�- 1 G 8 2 Track Left INC C 1 3 9� 270 � � l� 21 2 Za Scance b �wnwer IN� S 2 8a 160 ' 1 b 2� 4 Za Dovv�lli t General D�L, F 4 84 �3� ; 17 5 1 3 Chandelier b Owner INC DC2 � 100� 2��a ' 1 S � 2 3 Sconce b �wnwer II�TT� S ? 80 -_ = 5 6� I I9 11 3 3 Daunli ht Center DFL F 8 84 6�2 .