Loading...
HomeMy WebLinkAboutVAIL VALLEY FILING 3 LOT 15 PART 1 LEGALCOa'rf,.$aW tEl,El-CFEilI Design Review Boad ACTIO]I FORI,I Department of Community Development 75 South Frontage Road, Vail. Colorado 81657 tel: 970.479.2139 fax: 97o.479.2452 web: www,vailgov,com Project l{ame: SNOWSTORM SIOUGHTCHANGE Prciect Description: REMOVE AND REPAIR LEAKING SI(LIGHTS Pafticipants: DRB Number: DR8080115 owNER SNOWSTORM LLC 0412312008 C/OTURCAN CONNELLWS ATTN: RF SALTIRE CT 20 CASTLE TERRACE, EDINBURGH EH1 2ET, SCOTLAND APPLICANT NEDBOCONSTRUfiON 0412312008Phone:970-845-1001 Project Address: 2OO9 SUNBURST I-ANE Legal DescripUon: Parcel Number: Comments: P.O. BOX 3419 VAIL co 81658 License: 251-A 2OO9 SUNBURST DR VAIL Locationr Lot: 15 Block Subdivision: VAIL VALLEY 3RD FILING 2101-102-0100-2 SEE CONDMONS BOARD/STAFF ACTION ACtiON: STAFFAPP Date of Approval= 04123/2008 Cond:8 (P|-AN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Entry: 0412312008 By: RLF Action: COND 1. THE APPUCANT SHALL NOT REMOVE/REPLACE/REPAIR MORE THAN 25Vo OF THE WOOD SHAKE. Cond:0 (PLAN); DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activiUes. Cond: 201 (P|-AN): DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS, Cond:202 (P|-AN): Approval of this project shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construction is Motion By: Seond By: Vote: Conditions: commenced and is diligently pursued toward completion. Planner: MCHEL FRIEDE DRB Fee Paid: $20.00 Minor Exterior Alterati Application for Design R Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2128 fax: 97 0.479.2452 web: www.vailgov.com General InformaUon: All projects requiring design review must receive approval prior to submifting a building permit application. Please refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval lapses unless a building permit is issued and construction commences withln one year of the approval. Description of the Request:t kf 1/ 6 t-lrt LocationoftheProposat: t-ot: /il Block:-subdivisioni l/4/c t/4LLEy ?po F/L/w Physical Address:2aoQ .fu<t3u.<sf .tA.uE Parcef ifo.: 2 /O / / 6 2O t OO Z (Contact Eagle Co. Assessor at 970-328-8640 for parcel no.) Zoning: Ptr S Name(s) of Owner(s):Shlott1sT-o/21,1 ltc c/n Y/,4-:US fRtg7tr7a Owner(s) Signature(s): Mailing Address:8-* €Y/€//,4 iL (o Flc \-X Phone: 7/.r--/o<t / Fax: F+,;-qe'zc I-O\Jli ',./ ri'r I Mailing Address: Name of Applicant: E-mail Address: Type of Review and Fee: tr Signs tr Conceptual Review tr New ConstructionD Addition tr Minor Alteration (multi-family/commercial) 9--Jvlinor Alteration' (single-family/duplex) ! Changes to Approved Plans ! Separation Request $50 Plus $1.00 per square foot of total sign area. No Fee $650 For construction of a new building or demo/rebuild. $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). $250 For minor changes to buildings and site improvements, such as, re-roofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvements, such as, re-roofing. painting, window additions, landscaping, fences and retaining walls, etc. $20 For revisions to plans already approved by Planning Staff or the Design Review Board. No Fee CheckF.'.'o?ltJl""2t3|'''' MINOR EXTERIOR ALTERATIONS TO BUITDINGS AND SITE IMPROVEMENTS SU BMITTAL REQUIREMENTS General Information: This application is required for proposals involving minor erterior alterations and/or site improvements. Proposals to add landscaping do not require DRB approval unless they involve the addition of patios, water features, grading, or the addition of retaining walls, I. SUBMITTAL REOUIREMEI{TS** o Stamped Topographic Survey*o Site and Grading Plan* a LandscaDe Planxo Architectural Elevations*o Exterior color and material samples and specifications.o Architectural Floor Plans*o Lighting Plan* and Cut-sheet(s) for proposed fixtures o - Title report, including Schedules A & B to verify ownership and easements*( Photos of the existing site and adjacent structures, where applicable.o Written approval from a condominium association, landlord, and joint owner, if applicableo Site-specific Geological Hazard Report, if applicable*o The Administrator and/or DRB may require the submission of additional plans, drawings, specifications, samples and other materials (including a model) if deemed necessary to determine whether a project will comply with Design Guidelines or if the intent of the proposal is not clearly indicated. Pleose subm three (J,) capfus a/the malen'a/s ttolel uftl oz asleris* (). *xFor interior conversions with no exterior changes, the submittal requirements include a complete set of existing and proposed floor plans, a title report, and written approval from a condominium association, landlord, and joint owner, if applicable, I have read and understand the above listed submittal requirements: Project Name: Contractor Signatu Date Signed q/zr/ot F: \cdev\FORMS\Permits\Planning\Old forms\drb_minor_alL8-28-2007.doc Page 3 of 13 Topographic survey: I Wet stamp and signature of a licensed surveyor! Date of survey u North arrow and graphic bar scaletl Scafe of l"=Lo'or 1"=20) Lt Legal description and physical addresstl Lot size and buildable area (buildable area excludes red hazard avalanche, slopes greater than 40o/o, and floodplain) tr Ties to existing benchmark, either USGS landmark or sewer invert. This information must be clearly stated on the survey f Property boundaries to the nearest hundredth (.01) of a foot accuracy. Distances and bearings and a basis of bearing must be shown. Show existing pins or monuments found and their relationship to the established corner.I Show right of way and property lines; including bearings, distances and curve information.I Indicate all easements identified on the subdivision plat and recorded against the property as indicated in the title report. List any easement restrictions.tl Spot Elevations at the edge of asphalt, along the street frontage of the property at twenty-five foot intervals (25'), and a minimum of one spot elevations on either side of the lot.ll Topographic conditions at two foot contour intervals ! Existing trees or groups of trees having trunks with diameters of 4" or more, as measured from a point one foot above grade. ! Rock outcroppings and other significant natural features (large boulders, intermittent streams, etc,). f All existing improvements (including foundation walls, roof overhangs, building overhangs, etc.).t Environmental Hazards (ie. rockfall, debris flow, avalanche, wetlands, floodplain, soils)r Watercourse setbacks, if applicable (show centerline and edge of stream or creek in addition to the required strea m or creak setback)rl Show all utility meter locations, including any pedestals on site or in the right-of-way adjacent to the site. Exact location of existing utility sources and proposed service lines from their source to the structure. Utilities to include:! Cable TV Sewer Gas ,-l Teleohone Water Electric! Size and type of drainage culverts, swales, etc.tl Adjacent roadways labeled and edge of asphalt for both sides of the roadway shown for a minimum of 250' in either direction from property. I Site and Grading Plan: I Scale of L"--20' or larger I Property and setback linesJ Existing and proposed easements r-.1 Existing and proposed grades tl Existing and proposed layout of buildings and other structures including decks, patios, fences and walls. Indicate the foundation with a dashed line and the roof edge with a solid line.ll All proposed roof ridge lines with proposed ridge elevations. Indicate existing and proposed grades shown underneath all roof lines. This will be used to calculate building height.! Proposed driveways, including percent slope and spot elevations at the property line, garage slab and as necessary along the centerline of the driveway to accurately reflect grade. t A 4' wide unheated concrete pan at the edge of asphalt for driveways that exit the street in an uohill direction. I Locations of all utilities including existing sources and proposed service lines from sources to the structures. ! Proposed surface drainage on and off-site.u Location of landscaoed areas.u Location of limits of disturbance fencing! Location of all required parking spaces F:\cdev\FoRMs\Permits\Planning\Old forms\drb_minor_alt_8-28-2007.doc Page 4 of 13 :l snow storage areas.: Proposed dumpster location and detail of dumpster enclosure.I Retaining walls with proposed elevations at top and bottom of walls. A detailed cross-section and elevation drawings shall be provided on the plan or separate sheet. Stamped engineering drawings are required for walls between 4'and 6'feet in height.u Delineate areas to be phased and appropriate Uming, if applicable tr Landscape Plan:u Scale of 1" = 20'or larger! Landscape plan must be drawn at the same scale as the site plan. I Location of existing trees, 4" diameter or larger. Indicate trees to remain, to be relocated (including new location), and to be removed, Large stands of trees may be shown (as bubble) if the strand is not being affected by the proposed improvements and grading.! Indicate all existing ground cover and shrubs.f Detailed legend, listing the type and size (caliper for deciduous trees, height for conifers, gallon size for shrubs and height for foundation shrubs) of all the existing and proposed plant material including ground cover.I Delineate critical root zones for existing trees in close proximity to site grading and construction.I Indicate the location of all proposed plantings.I The location and type of existing and proposed watering systems to be employed in caring for plant material following its installation.! Existing and proposed contour lines. Retaining walls shall be included with the top of wall and the boftom of wall elevations noted. lJ Lighting Plan:! Indicate type, location and number of fixtures,D Include height above grade, lumens output, luminous areaI Attach a cut sheet for each proposed fixture. t] REPAINT PROPOSALS ll For all proposals to repaint existing buildings, the following supplemental information is required: ! Color chip or color sample including the manufacturer name and color number(s)f Architectural elevation drawings which clearly indicate the location of proposed colors (ie. siding, stucco, window trim, doors, fascia, soffiits, etc,) F:\cdev\FORMS\Permits\Planning\Old forms\drb_minor_alt_8-28-2007.doc Page 5 of 13 Buildino lvlaterials PROPOSED MATERIALS Tvoe of Material Roof Siding Other Wall Materials Fascia Sotrits Windows Window Trim Doors Door Trim Hand or Deck Rails Flues Flashing Chimneys Trash Enclosures Greenhouses Retaining Walls Exterior Lighting g16sy{p7uerf15 (eraar< f, mnrct+ €xsn& 6H4rc(J Color /U47.)42( DESIGN REVIEW STAFF APPROVAI- Notes: Please speciry the manufacturer's name, the color name and number and attach a color chip. TDV/N OF \iAfL /WaCq- fo rn4r(H EflSv''t F.A"l-i- F, llF F:\cdev\FoRMS\Pemits\Planning\Old brms\drb_minor_alL8-28-2007.doc land Title Guarantee Gompany YOUR COilTACTS DrtAr 0t-3s?00t oronlerNumb*r vnwEl hopcrtyAddrers: LOT 15, YAILVAIJ.EY, TIIIRD FIUNC Buycr/Eorrovor: TOEBDETEN,MIMD Scllq/Ovncr: SNOTIISTORM I LC, A DEIAWARB IJIUFEI; OA$UTY COMPAI{Y ! f ou qtc qy tngglrles or reqdrt lrrrher esslrtilcr, pl€arc .oillct one of thc nuuber5 bdon':f,or Ood.g ArgLit nca: For fitte Acrisbrc V:NilTl&De?t Roger Avila 108 s. FRoMAGERD. W. #203- P.O. BO,C357 VAIL, CO 81657 ?tr.,ina 97V476.n5L Fly.t t7041645M EMrtL nvtle@lt3c.co TIIA}IX YOU }!R YOTN ONDEru ESTIMATE OFTITLE FEIS Informatioq Biarh 0775.00 TOTIl izTs . o0 It ! l:r/1r{/E{:Jq . FACIE 7,0 'A qgBZ /'b nln '0N xr,'l SlnqlIHnHH gg?l'l 'l{'} LJH In:nl II'l znnz-,7-Jqs Chiego fidc llsmnco Compeay ALTA COMMITMBNT SdeihlcA Our Orilsr No. I2ill4El Cwt.Rd.r Frope#y Adilnse: LOT 15, VAILVALLEY, TIIIRD FILING l. EltcglvcDatcr )rnrary 19, 2001 r J:00 p.lr{. 2. Pollcy to bc kru{ anrl hopoced lrsured: lnfoumlioq Bililcr Proposodlrrsrn* TOEEDETERMINBD 3. fttc estrta or intcrrrt in thc luil dcscdbed or refrrrtd !o h tDls Copdt6ut 1ad C1vered bcrda lg: AFcc Slnplc 4. fidt to tho esds or ld€rcc covcrcd lerpln k ar ih dtecSva ihfe her€of vcded in: sNo]vyroRM I rc, A DEIAWARE UTdITED IIABIUTY COM?ANr 5. Thc hud rrfcrrcd to in thit Cormltnent ls ilcscrlDed c folloqc.l LOT rs, vArL VArt Ey llqp: Iq4,{O, ACCORDING TO THE pLAs T,ECORDED AUGIJST 30, rWIN BOOK 259 Af PAGE 69, COUNTY Oi BAGLE, STArE OF COI,RADO, .. .!& !av||lltf,altt l E E tvt tC lt,4'ftj453l|FAOE s.t.0Ll.lH0HU Hflct't 'H') uu In:nt r)f'{ 7.nn7.-17.-A7s996Z LLN O/B 'ON XUJt0 'd tD. aJ la.l'164534 FAGE ALTA CO}TMITMBNT ScterNcB-Soctionl (Rcq,rlrtneoSr) Tbe fotlondng are llre ro$rtr.rne8 to bo couplled wflh: OurOrdenNo, Ylll481 ItcB (r) Prynerr to of for 60 accouu of 6e grottxs or mongagors of rhc ir[ cossideration for rDc cstate orlDt€re$ !o bo lD$!cd. Iteo (t) Propcr bsrnurar(s) clcarllt 6s csbtc or i,Ettrrcrt to bc iasured rurst bc erccutcd ard duly fl1g{l for rcco(ll,to-wit: Itsm G) peyocat of a[ hxx, r:hargls or aoceem,o|lts loried and qrgessed rylrst A9 subject prcrlses vfrich aro Clerudpafeblc. Itis (d) Addiriofrl tquiremens, if tny disctosedbctowr THIS COMMITMENT IS IOR TNFORMATION ONLY, AID NO POilCY WLL BE ISSUED PT RSUAI\IT I&RETO. LLVt0 'd 99Be 0i0 '0N xuc SJCIJIHCUU 883f4 'H')| ilU In:nl I)l{ znnz-,z-,.t?s r- .1r!tr se.rtE'rrt.rEE rl'/t: r!r7u{,,u{:r3.. PAGE s ALTA COMMITMENT SchalulcB - Secdon2 @=crptions)OwOrdcrNo, vTll481 {ts pqtcy or Folldrc to bc isrucd ti[ onhh *cepions to thc follontng unlcs lbe gamc are dsposcd of to ilrc ratirfedioo of tbc Conpury: l, Rlt[ts or ctriD! of Frtii$ h fossessiol tro! E[owtr Dy lhe Frblic rccords. 2, Fas€rornts, or cJairns of crscucas, nor Sorrn by thc Dubllc recor(s. ?' Discrvg.rncies, codicts ir borntlrry tirrcs, shorugc b a$a, cDAroacbmcDb, ailt lry facb whict a ooneet srwey aldiupccliol of thc p'rtrrriscs c/ould disclosc rst vhicl trs aot sho\n by rhe gollic ncorils. 4, eny -Uro or riAt o r llco, for serviccs, lsor or natedd rtcrerofore or trcreafter fudsbed, inposcd hy lew anrl aot shown by tte publlo records. 5. Dcfectg' liens cncumbnucw, aahrm* cbilrs or otlq nattcn, if rny, crcatcel, first aFl,cui4 in thc public rccor6s or rycnip rubscqscnt to lhe cflcctive,tntc hcttof butpior roihc dir. t pr6pos.a itiit*a-*r"i*-.f fi;6 i,tr - vahre ihc csae or furcrcst or mongrgc thacon covcreo Dt rhrs codlarh(it.' 6. Ta*cr or rycciet e'Fcsscnts sAicl rrE Dot stowr s$ orixiry tiens by dre yrblic recordc,o 6q Trcasurrrrs ofilce. 7. Ucog for uotri4 eater ald sowor clutgcgl if any.. 8. In rdditioa thc orvnrr's Inllcy will te subject tr &e lrortgrge, if rry, mtcd in Sscrion 1 of Sulcdulc B her.of. 9. NGIIT OF PROPRIETOR OF A YEIN OR LODE TO E'XTRACT AND REMO\NE HIS ORE THEREFROM SIIO1ILD NTE SAMS CB FOIND TO PENEIR.IIE OR INTEX.SECT TTIE PRIMISESAs RSSBRVED IN uNrrED srAlEs PATEtlr RBCORDBD EINE 29, t 9ot, tl r BooK 48 AtPA6!495. IO. RESTAICIIVE COVENANTS WHICH DO NOT CONTAIN A PORFEITURI OR RBVEIITER CLAUSE, EUT OMITTING ANY COVENANT' ON. RESIRICNq{ BASED ON RACE, COLOR, REIICION,Sffi, T'ANDICAP, FAIdILIAL STATUS OR NATIONAL ONGIN UNLESS'AI.IP ONLY TO THgEXfEIIIT THAT SAID COVENAI{I (A) IS E5(EMPT UNDER CI|APTET. AE, iNCTTOU 16AI Or TI{E IINTMD STATES CODE OR O) REIJTSS TO ITANDICAP BUr DOIiS NOTD[tCIUMlNArs AGAINST IIAI{DICAP PERSOI.IS, As CONIAINED fN nrsrnUr'm,rr RBcORDED AUCUST 30, I97, IN COOK 259 AT pACE 68. I I. UTITITY IjASEN'ENT AS CN.UTTPO TO VAII. WATER AI{D SAI{ITATION DISTRICT ININSTRUME!{T RECORDED TEBRUARY 5, 1969, IN DOOK 2I4 AT PACB EIZ iIrP RBCORDED OSTOFER 20, t969 rN EOOK 216 AT pAOE 2tz. 12. UNDTVIDBD tlz INTEREST IN AND To AtI ol THE GAs. oll. A.N|D oD{.eR MINBRALS, SO-LID UQUTD AT{D GASEOUS, OF EVERY I(ND Ir.rP Nrrr:ru, TUCLUDNC URA}.IIUM, IN ON AND UNDTR ANY AID WIIICH MAY BE PRODUCED FRoM tHtTloRTtON oF suBJEcTPROPERTY IN SBCTION IO OF LEGAL DBSCRFTION HEN,ETO AS EXPEC"TBD AND 90 'd 9962 Ll,b 0/.6 '0N XUJ S.l.0q.l.lH0llH HflqM 'H'v UU zn:nl l)l'{ ?.nn7.-t7.-Ans, . . ar.E urr|||sAti I EE ID! l9 704 784 534 FAGE ALTA COMMITMENT SchedulcE.Sccdoa2 (ExctPdone) Out OrdenNo. Vnl*l T-tc policy or potldcs ro be lcsusd will courrln erccptlors ro t[e fol]owing unlrss lhe sarta qo 6lsporcdof to thestlsfactlon of tlc Comparyl RES-ERVED BY P81ER E. KATSOS IN DEEb RECORDED MAY 3, 1960 N BOOK 16$ ATPAGE2:N. 13- UIILITY EAS!:MBNT ALONG TllE SOuTI{lvEYIrr.r:r, SourUBnsTnnry AND NoRTHEASTER.LYLOT LINES OF SIJBJICI' PROPBiTY ES irIOq/N OU TIIE ?LAT OF VAIL VALI.B'r THIRDFluNo. 14. D-R.AINAGE EAS'MEST?,5 FBET AI,ONC 1IIB NORTIIWESTERLY LOT LINB OF SUB'ECTPROPERIY AS SHOTW ON TlG RECORPXPFT,Af Or VrN VILEY THIN.D FILINO. 90 'd 9962 LLV 016 '0N XVJ s,l,cl.l.lH0Hu SHll'l 'H') ilu zninl rH,{ 7,nn7,-t7,-Aqs ^ rL& irlrlrts Fur| I EE I t) r 197@4784534 PAGE LAND TITLE GUARANTEE COMPANY DISCLOSURP STAIEMENT Fcq'dred by C.R.S. l0-U-r22 A) The rubjecr reel propony rusy bc locared in a special hriug <listrict. B) A c.ctifcar of rares Duc listug c6ct i-:ring judsdiaion nay be obhinerl ftom ee coulry Treasursr's authodzod rgear Q rhc infonoarion regEraing specral diarius aod rhe boudtiqs of suct districrs nay bc obtaiaed &om &e Boarrt or co.nty commissioucrs, the coumy clut ana neco?ou, or the Cormty Asscssor. Effectivc scpteuber l, 199-, cRs 3Gl0406 reErires Oa aI rloqnelrs nseiw4 fot recording or Eling in ft,,dctk anl recoirler's ofEce shall ryr$n a top nargil of at lcatl orr t"o rnn a frn, tiglt a16 bottoan nargin ofat le8se o!9 hslf of ur inch- The cle* and rceordi raay refirsc to r6cud or fitc aly air.*t $at iloes norcou'fom, cxcpt that, the reqpirenent for the top margin sball not apply ro Oocuufub usiflg fo." on wfiospace is providcrl .firt recordi4g or fliog iorornriion ar rle top nurun 6ru. aocr-*t. Noh: Cotorado Division of Insurarce Rcgrrlatioos 3.5J , Pengraph C of Anicle VII reqoires rbat 'Evetytide eufty Fa! te rcsporuiblc &r a[ naGn wbich aperr of-rcconl p;o' m oc dme "i r.*Ji"grrhcaevc tte titlc entitv con&rct thcclosiag atut is riEromirrte for tu*tmos oiairg orr.grl9q-*6 Tqri{g t'ou rhe trarsrctioa wt]ch wes clo-sca'- provided that hud TitlJ auerrnrce Compary coaducts rhe closiog of rhe insured transactiol arrrl is tespouribte for recortling thcleg'l docuDeDts from the tran:srction, exception nurnber 5 wilt mt agpcar on ttc iler's TitlcPolicy ud thc Lexlers Dolicy whcn irrwcdi -''r7--- --- Nocc Alfiruativr: mcc.bruic'g liert gro|ecriol for thc Onrc oay be awilablc(tygically b,y deletioDof EmcPd.t no. 4 of Sclredule B, Sectioa 2 of rhe Couriaatri ftom rtr.. O.*oei's f&icy to beissqed) ugon, conptiancE with rlc followfurg coxlirions; A' Thc t|!d rlcscxrtcit ia Schedole A of rlrii cornf,itoeat rDnsr be e single frrdly residence whicb include.s e condoninirm q toqDhousc uDiL ., B. No labsr or uatcrids havc bscu furrrisftc1t Sy nccbanics or E|eriol-netr for F$poses ofcorrstuctioro thc r^'''l dhscEit€d io Schgtule A of rhls Conni!rcnt wiOtn'u,ipust 6Dg[Urs.c- Thc_ conpany mus! receive an alpropriar Nfndsvir iulruifyi"e d; c"qp."t;ffio un-filcdmcclnnic's ald natcrlal-nca.S liens.- 9- 1[: Crypilry m$ir receive payueur of &c appropriate pruuiorn, E. lf therc lrs beeu constnrctiou" irprwenenror najor ripairs undertirken on tle gopeny roItc lrucbascd wiihin six montlu prirrr !o 0r Date of tfr, C.r**rru.ol, Oe rccuiddx to obtalneoveHgc for urecordcd liers will inctu&: disclosnre of cutain coasirucUoo'iofonnation;fnalcial hforration as ro rhe sclrer, r[e buildcr atd or the contractor: ty..rtt;f ,h" rppnrpriate graniun fully exes.red bitcooiry Age€mcn$ satisfaatoryio ac cffiy, ao4aay additional rsquftemenb as nay be necessary ittcr al exaorinatioqif &e ,focsaiUtntorneriot by &e Conpaly, No wve.lilge will hc givea under any circumsFncrs for lcbor or rutcricl to( which thc in.:ured 083 cotrtrtcte(l for Cu irgrred to pay. Notrirrg hereil conraird will be deemcrl ro obligare the coqury to provide auy of thecwtragcs reltrred to hcrcin unlcss Ac ehr"e coiditions .1rc firlly sati!fiea. l0 'd 9962 LLV 016 '0N XUJ SI0SJIHCUV g8til 't{'I ilU Z0:0t IUJ Z00ZrZ-J!S * * * * *****t**t1****++*!t******++!t'l*'i!t*'l'l'l*'i{'{'*{'l'l'*** * + ****ttf f **********f 't't'}'t*********'}l't'+'}'}'}'t TOWNOFVAIL, COLORADO Stat€metrt Statement Number: Ro80ooo513 Anount: $20.00 04/23/2o0e02:54 PM Payment Method: Check Init ! RLF Notsation: 34148 NEDBO CONSTRUCTION Permit. No: DRBo80115 Type: DRB-Minor A1t, gFR/DuP Parcel No: 2101- 102 - 0100 - 2 Sitse Addrees: 2009 SUNBITRST DR VAIL Location: 2OO9 SI'NBITRST LANE Total Feea: $20 - oo This Palment: S20.00 ToEaI ALI, Pmt6: $2O.OOBalance: $0.00 't*'f***'t*t{,'}************'}*****************!t****'t't*'f{r****at++t**t**********t*t*******'}*'l'}*+*** ACCOI.JNT ITEM LIST: Accorrnt Code Deacription Currents Pmts DR OO1OOOO3LL22OO DESTGIN REVTEW FEES 20.00 o o"13? Design Review Board ACTIOI{ FORM D€partment of Community Development 75 South Frontage Road, Vail. Colorado 81657 tel: 970.479.2139 taxi970.479.2452 web: www.vailgov.comoclififi oEvEL0Fr€uI Project Name: SNOWSTORM LLCTREE RELOCATATION DRB Number: DR8050577 Project Description: Request to relocated 3 exisiting trees to new location within the lot. Participants: OWNER SNOWSTORM LLC rol24l2o0s C/O TURCAN CONNELL WS ATTN: RF SALTIRE CT 20 CASTLE TERMCE, EDINBURGH EH1 2ET, SCOTI.AND APPLICATIT NEDBOCONSTRUCIION LOl24l?:WSPhone:970-845-1001 P.O. BOX 3419 VAIL co 81658 License: 251-A CONTMCTORNEDBOCONSTRUCIION LOl24l2O0S Phone:970-845-1001 P.O. BOX 3419 VAIL co 816s8 License: 251-4 Project Address: 2009 SUNBURST DR VAIL Location: 2009 SUNBURST Legal Descriptionr Lot: 15 Block SubdMsion: VAIL VALIEY 3RD FIUNG Parcel Number: 2101-102-0100-2 Comments: See Conditions Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION Action: STAFFAPR Date of Approvah 0al0312006 Cond:8 (P|-AN): No changes to these plans may be made without the written @nsent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to consbuction activities. Cond: 201 DRB approval shall not become valid for 20 days following the date of approval. Cond: 202 Approval of this project shall lapse and become void one (1) year following the date ornnatapptal, unless a building pennit is lssued and ttruoon is commenoed and is dil[endy pursued toward complefion. Cond: CON0007921 That the applicant contact George Chalberg (n-3507) of the Publk Worl(s Dcparfnent to coordinate access to the site from Toryn of Vail lands and rightsof-way. The applicant will be responsible for ompleting all paper r,,rork and palng all ftes assodated with such access permlts. The applicant will In be responsible br raregiataUng any disturbed areas and repair any damage that may occur with sudr aess prior to final Planning Apprcval. Cond: CON0007922 The appllcant shall replace any of the relocated trees which dle wlthin 3 years of being tnnsplanted wi$ a similar species btaling the height of the deessed bee. As an o<amph if a 30 fmt tall tree dles tfie replacernent tree heBhts must total that of the decessed hee. Planner: WanenCampbell DRB Fee Pald: 120.00 1 Minor Exterior Alteratls Ipplication for Design Review V,*-, u-atl-Q T Depaftment of Community Development 75 South Frontage Road, Vail, Colondo 81657 tel: 970.479.2L28 fax; 970.479.2452 web: www,vailgov.com General Information: All pqects requiring design review must receive approval prior to submitting a building permit application. Please refer to the submittal requirements for the pafticular approval that is requested. An application for Design Review cannot be accefied until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval lapses unless a building permit is issued and construction commences within one year of the apprcval. DescripUon of the Request: Location of the Proposal: Lot: / s- Block- Physical Addrcss: parcel No.: p /^ | / O e- A l OOZ (Contact Eagle @. Assessor at 970-328-8640 for parcel no.) Name(s)ofowner(s): f ^ ,'s-l-rr- LI{ eforuzca^lro-u,uecc uts 4rr<l Name of Applicant: Mailing Address: E-mail Address:Fax: $50 Plus $1.00 per square foot oftotal sign area. No Fee $650 For construction of a new building or demo/rebuild, $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). $250 For minor changes to buildings and site improvements, such as, re-roofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvements, such as, re-roofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For revisions to plans already approved by Planning Staff or the Design Review Board. No Fee Feo t/)o NJ --...) Type of Review and Fee: tr Signs E Conceptual Review tr New Constructiontr MdiUon tr Minor Alteration (multi-family/commercial) F/ Minor Alteration (sing le-family/duplex) tr Changes to Approved Plans O Separation Request Malling Address: Owner(s) Slgnature(s): Phone: fui+qt *+i*++*'i******t**,1'*i'tlr{r**************+++***+++'1.*++**t*****+*t***++************************** TOWNOFVAIL. COLORADO Statement*+**t************+**l'********{.*******l+********f+********:}*+++*********,}************+**+tft+ Statement Number: RO5OOO1?91 Amount: $20.00 tO/24/2Oo5O2 52 PYI Palment Method: Check CONST Inits : iIS Notation: 28?33/NEDBO Permit No: Parcel lilo: Site Addreee: Location: Thie Payment.: ACCOI.]NT ITEM LIST: Account. Code DR 0010 00 03 LL2200 DR8050577 T)T)e: DRB-Minor Att, SFR/DUP 2101-102-0100-2 2OO9 SI'NBURST DR VAIL 2OO9 SI'NBURST $2o. oo Total Fees: TotsaI AL,L Pmts : Balance: Descriptsion DESIGN REVIEW FEES $20.00 $20.00 $0.00 Current Pmta 20.00 Me &^^r,il ^hd^,^,.,*l,,bo tr*}'"H\;t*^4J dt^ -hyk' ^T,,*lA ,Ar Mi I!,A*; @- U; ^A,,yH *,d, A*^.1.1 -,;fuJ ffil Mr^z tu1r,n ,6 G'r* Jr*--*,:HMM nV/D /\/\!r4 U WM,AL-Y q/\ffiL ^^MoaJ)" llft:^: b",^* 7e, il^X,^ U'fu, S' o-o rnt))p U -r ;J) z \L \ l lLq I t>'-:tI,---I l@,l, o kil !:)- '// ,._f ,, / ^{-"-;Dl / # iq//rt)/tu /fr / ,LV r(// tu'' rAY/>. (Y o( t'. I nsi I IlJnAt Ozz !w- =-t-sJ I _p*- \ eou o *Y 4-Y 'jrd7 '/1,' I /' . ,,' \7 |___...\, 'l-h_/\ : s'/__/ ,',/ ,i/ /l \ i:.\ 4/ #i'h tY / r'r / tft )< Design Review Board ACTION FORM Deparbnent of Community Development 75 South Frontage Road, Vail, Colorado 81657 teli 970.479.2139 fax: 970.479.2452 web: www.ci.vail.co.us Project Name: Exterior stair addition to east deck. DRB Number: DR8020368 Project llescription: Add exterior stair to east elevation deck Pafticipants: OWNER SNOWSTORM LLC 10/1412002 Phone: C/O TURCAN CONNELI WS ATTN: RF SALTIRE CT 20 CASTLE TERMCE, EDINBURGH EH1 2Er, SCOTT-AND License: APPUCANT KH Webb Architects L0lL4l2OO2 Phone:477-2990 953 S. Frontage Rd West Ste 216 Vail, CO 81657 License: Project Address: 2009 SUNBURST DR VAIL Location: east deck Legal ttescription: Lot: 15 Block: Subdivision: VAIL VALLEY 3RD FIUNG Parcel Number: 210110201002 Comments: Replace small aspen @ landscape plan Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION ACtiON: STAFFAPR Date of Approvalz LOl t7 12002 Cond:8 (P|-AN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate renriew committee(s). Entryt I01L712002 By: MG Action: AP General landscape plan to be submitted in spring for Hanks and neighbor property (same owner). Cond:0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activiUes. Pranner: /rtf /**JL DRB Fee Paid: $20.00 Questions? Call the Planning Staff at 479-2138 APPLICATION FOR DESIGN REVIEW APPROVAL GENERAL INFORMATION This application is for any project requiring Design Review approval. Any project requiring design review must receive Design Review approval prior to submitting for a building permit. For specific information, see the submiftal requirements for the particular approval that is requested. The application cannot be accepted until all the required information is submitted. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design Review Board approval expires one year after final approval unless a building permit is issued and construction is started. A. DESCRIPTION OF THE REQUEST: Add exterior stair to deck, East elevation B. LOCATION OF PROPOSAL: LOT: 15 BLOCK:FILING: Vail Valley Third Filing PHYSICAL ADDRESS: 2009 Sunburst Drive, Vail, Colorado C. PARCEL #:2101102O'1002 (Contact Eagle Co. Assessors Office at 970-328-8640 for parcel #) D. ZONING: Residential (Type R Div. 1) E. NAME OF OWNER(S): Snowstorm, LLC MAILING ADDRESS: c/o Attorney; PO Box 2747 Edwads, Co 81632; Attn: Diane Larson owNER(s) sfcNAruRE(s), A/* 4rZ PHONE 970-926-9100 Vail Professional Bldg. Ste.216 Vail, Co 81657 PHONE 970-477-2990 G. NAME OF APPLICANT: KH Webb Architects MAILING ADDRESS: 953 So. Frontaoe Rd. West H.TYPE OF REVIEW AND FEE: New Construction - Addition - Minor Alteration - Minor Alteration $200 Construction of a new building. $50 Includes any addition where square footage is added to any residential or commercial building. $20 Includes minor changes to buildings and site improvements, such as, reroofing, painting, window additions, landscaping, fences and retaining walls, etc. DRB fees are to be paid at the time of submittal. Later, when applying for a building permit, please identiry the accurate valuation of the poect. The Town of Vail will adjust the fee according to the project valuation. PLEASE SUBMIT THIS APPLICATION. ALL SUBMITTAL REQU]REMENTS AND THE FEE TO THE DEPARTMENT OF COMMUNITY DEVELOPMENT, 75 SOUTH FRONTAGE ROAD, VAIL, COLORADO 81657. REC:r'::0 OCT I + moZ For Office Use Only: ao Fee Paid: 79 : Application Date: PreApplication Meeting Date: cx*: i|fi By: DRB Meetino Date: /fft|. oru-T-,4twz-0n06 ,,\e BUILDING MATERIALS: Roof Siding Other Wall Materials Fascia Soffits Windows Window Trim Doors Door Trim Hand or Deck Rails Flashing Chimneys Trash Enclosures Greenhouses Retaining Walls Exterior Lighting LIST OF PROPOSED MATERIALS TYPE OF MATERIAL:COLOR: metal pan with stone paver to match existing at deck; Wood siding to match existing at house "Please specify the manufacturers color, number and attach a small color chip ..Alf exterior lighting must meet the Towns Lighting Ordinance 12-11-5J.lf exterior lighting is proposed, please indicate the number of fixtures and locations on a separate lighting plan. ldentifo each fixture type and provide the height above grade, lumens output, luminous area, and attach a cul sheet of the lighting fixtures. Other: Stair PROPOSED LANDSCAPING Botanical Name:Common Name: Quantity: Size.: PROPOSED TREES AND SHRUBS: EXISTING TREES TO BEREMoVED: Populus Tremuloides Aspen *Minimum requirements for landscaping: deciduous trees - 2 inch caliper coniferous trees - 6 feet in height shrubs - 5 gallons Tvoe:Souare Footiaqe: GROUND COVER SOD SEED IRRIGATION TYPE OF EROSION CONTROL OTHER LANDSCAPE FEATURES (retaining walls, fences, swimming pools, etc.) Please specify. Indicate top and bottom elevations of retaining walls. Maximum height of walls within the front setback is 3 feet. Maximum height of walls elsewhere on the property is 6 feet. 2" ON oobnt o OJ .2 6 : =('/) uJ LJz IIJo6l!d \lz I E ,..\zhe 9-F ;z \J IIJ-t- '- n E3 ,n ri:i u..r I =6Z 3H d9Hi g* frHoE ,-# oozd ot zP EH UE E318 B= il9 ! YP.* F9 R fl,,fr s* g:e zav H6 >=g3=4 HE ?V=IxJ Fo ddkF:.h =fE d-=-7gei =** t2z2eg9 H; d a'i-e?g<b =Y* .l9aS qnE;i=ii;E Een ;;g ;==?T I I I uJL,f I lt- t a UJFz -o q) 3 \ZUtllo G) (9z?u.rF6=="9 ' F IIJ 33uY r.lJ FEkf4ao-1 .-Fi3a 9*$oF<JLNCL zoF U..\ IIt- ui UJ z uJ a uJJ z6 uJ =uJ d. FtJl to E t.uFXtu =uJz z J ON :N =Fr; r.r =Fl OJ o =.o =u: uJ(Jz uJo -a UJ &. \Zz. I -o -o o = 2 = ? ae8 8fi q s=p a* 4 fiEi 9i ;8oi 5il..r 2 =iH 7=7 b EFA ="62 2z6T. Qz J = o IUF uJ =,z) <Yi!H ;5z.G u-a2 llJ i..\z.YJU) JJ = t! ITJ 6 T U k dFol; z.:5rnLU UIz1 =o\J =Fui u.r 3 ,nEH 6Z9T H= tn Ea\+ -n=;uJ- l-..|(J- 'ndf;= il8 zul Ul u.l J(9z6 uJ o uJ z E(J I-F- ui IJJ F uJo t (,z trIX uJ u- uJz = d F tn d.o &.tuFXtu =Luz zo tr IUJ l,,rJ Fa tu c'- (tl :>- d' (J /"\.= !"' X = LIJ --a =or-.1 '.8_ o)< -E ij r-!'= './t a6io&. 6 .--j v=<--=o)- cgr<o -rJJ- ?'1'' r r ,.{l "J rl : )'f"il .t --o --o =- --c e <D o <l) c a-< C, '.= d3 .-) =<l) - "{I L. ;*i{; i W i r: i o ==:>6 qj. r_) .= bo6.E e'2 ! u-r lt =Ot-r 't -- '€.ttcr, < e!€'E-,.-^ t.-, Oo., C>4 Ar{ v'=::€,)-Gt><€:E u-r - =c, :> o (at <I) l4l G'<u o -, -ct E) -- s I\ r'ranr 6xt*toe' a 6Prto+)i ct(n( uTtLtTY EASEMENT \ i\ ------ --l ,g' I ! I( I I I l{ $ brt o N ? NCr{EEffiJ a?fr3) PE I I II I I I I I I I I I I l.- t5 t,LOT .l o:dl-t I I onE ?u\\\ N.T. 6. SUNBURST DRIVE ( 40' ) \' I \ I 1i'o ebb +V$\VZertWvE @6&to? I'rfiF l+mol.lt6-l+4fi- -r-h A, //6o 47'25 " R = 46A62' L , t34.98' lc.h. rl >rr-;|ni*e.-t=-gc .'.d. f*** *+ *{. *{' t * * *t ** ** + * * ** {r !t+ +'t {' 't t t*****t* * * * *{'{r *** f* * *+*++ * * t f* ** *'t{'{' {' * '} **l' * *+** * *+***'}* t * *** TOWNOFVAIL, COLORADO Statement * *+* + **** +t * * t ****t* * * ****** l* +*rl ***+*+++* *t *+***t ******f**++********.1. * t ** * *++t + + *+****+ + +** SEatsement Number: R000003257 Amount: $20.00 LO/L4/200204:33 PM Palment Method: Check ARchitects Init: JAR Notsation: 3033 K.H.nebb Permit No: DR8020358 Parcel. No: 210110201002 Site Addrees: 2009 SI'NBIIRST DR IJocation: east deck Total" Fees:$20.00 This Payment: $20.00 Total AL,L Pmts: $20.00Balance: $0.00 * * *l' {.* +* 'l' {.'l*** '1. *i * * ** * 't * * i ** * ** t t * *** * * t ** {' 't 'l' *** * * * ** * ********+**********tl****l'*'t't*****+t +* ACCOUNT ITEM LIST: Account Code Current Pmts DR 00100003112200 DESIGN REVIEhl FEES 20.00 Tlpe: DRB- Chg to Appr P1ans VAII, Descri pti on TOI4'NM Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Oolorado 81657 tel: 970.479.2139 laxi 970.479.2452 web: www.ci.vail.co.us Proiect Name: Snowstorm minor alteration DRB Number: DR8020363 Project Description: Replace guardrails, deck pavers and front drive Pafticipants: OWNER SNOWSTORM LLC 10/04/2002 Phone: C/OTURCAN CONNELLWS ATTN: RF SALTIRE CT 20 CASTLE TERMCE, EDINBURGH EHl zET, SCOTT-AND License: APPUCANT WEBB, KYLE H. IOl04lZO02 Phone:477-2990 953 SO, FRONTAGE ROAD #216 VAIL, CO 81657 License: Project Address: 2009 SUNBURST DR VAIL Locauon: Legal Description: Lot: 15 Block: Subdivision: VAILVALLEY 3RD RLING Paroel Number: 210110201002 Comments: Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION Action: STAFFAPR Date of Approvah LQI LL|2OOZ Cond: 8 (P|-AN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s), Cond:0 (PLAN): DRB approval does not constltute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Planner:llait 6en-"1f DRB Fee Paid: $20.00 Questions? Call the Planning Staff at 479-2138 APPLICATION FOR DESIGN REVIEW APPROVAL GENERAL INFORMATION This application is for any project requiring Design Review approval. Any project requiring design review must receive Design Review approval prior to submitting for a building permit. For specific information, see the submittal requirements for the particular approval that is requested. The application cannot be accepted until all the required information is submitted. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design Review Board approval expires one year after final approval unless a building permit is issued and construction is started. A. DESCRIPTION OF THE REQUEST: Replace existing guardrails @ exterior deck(s) with new; replace pavers @ front drive with new-please see attached photos B. LOCATION OF PROPOSAL: LOT:15 BLOCK:FILING: Vail Valley Third Filing PHYSICAL ADDRESS: 2009 Sunburst Drive, Vail, Colorado C. PARCEL#:210110201002 (Contact Eagle Co. Assessors Otfice at 970-328-8640 for parcel #) OWNER(S) SIGNATURE(S):)-z/YT.)W-^f- €t<-lu-sfutzn, /4c. G. NAME OF APPLICANT: KH Webb Architects MAILING ADDRESS: 953 So. Frontage Rd. West Vail Professional Bldg. Ste. 216 Vail, Co 81657 PHONE 970-477-2990 D. ZONING: Residential (Type R Div. 1) E. NAME OF OWNER(S): Snowstorm, LLC MAILING ADDRESS: c/o Attorney; PO Box2747 TYPE OF REVIEW AND FEE: New Construction - Addition - Minor Alteration - For Office Use Only: Fee Paid: CK#: Application Date: Pre-Application Meeting Date: Edwards, Co 81632; Aftn: Diane Larson PHONE 970-926-9100 Minor Alteration $200 Construction of a new building. $50 Includes any addition where square footage is added to any residential or commercial building. $20 Includes minor changes to buildings and site improvements, such as, reroofing, painting, window additions, landscaping, fences and retaining walls, etc. H. DRB fees are to be paid at the time of submittal. Later, when applying for a building permit, please identify the accurate valuation of the project. The Town of Vail will adjust the fee according to the project valuation. PLEASE SUBMIT THIS APPLICATION, ALL SUBMITTAL REQUIREMENTS AND THE FEE TO THE DEPARTMENT OF COMMUNITY DEVELOPMENT, 75 SOUTH FRONTAGE ROAD, VAIL, COLORADO 81657. oRYJ ueetins oate: RECE\I ED /mU -0191' 1''- i I lmo BUILDING MATERIALS: Roof Siding Other Wall Materials Fascia Sofiits Windows Window Trim Doors Door Trim Hand or Deck Rails Flashing Chimneys Trash Enclosures Greenhouses Retaining Walls Exterior Lighting Other: Guardrail Driveway Paver LIST OF PROPOSED MATERIALS TYPE OF MATERIAL: Glass, copper Masonry Pavestone COLOR: "antique tena-cotta" 'Please speciff the manufacfurers color, number and attach a small color chip '*Aff exterior lighting must meet the Towns Lighting Ordinance 12-11-5J.lf exterior lighting is proposed, please indicate the number of fixtures and locations on a separate lighting plan. ldentify each fixture type and provide the height above grade, lumens output, luminous area, and aftach a cut sheet of the lighting fixtures JAN-3O-Ot t 5:46t FROM.LAND TITLE CUARANTEE tD. r97O4764S34 PAGE I [and Title Guarantee ComPanY GUSIOMER DISTRIBUIIOil Drter 01-30-2001 hopcrty Aikhcss: LOT 15, VAIL V.qLLEY, TIIIRD FTTJNG Our Ordtr Numbct Y27l4El ILTI. W8BBARCHITECT 953 S. FROI{TAOE RD, W, VAIL PROFBSSIOML BLDO., S(nlE 216 VAIL, CO 816t7 Attn: KYIJ WEBB Itonp; 90.{77-2990 Fsxr 9704T1-D65 Soot Vir Frx rlAN-3O-Ol t5:4€i a. FRO}I: LAND TITLE GUARANTEE lD' r 9704 ?64 5 34 PAGE 2oo Land Title Guarantee Gompany YOUB CO]ITAGTS D.re 01-3G2001 Dmprtf Arlilreec: LOT 15, VAIL VAILEY, THIRD FIUNC Buyer/Eorrower: TOBEDBTERMINBD Our OrderNumbcrr YTVEI Sdlcr/Orvncr: SNOWSTORM LLC, A DEI.,AWARB LNUTTEd LIA}IUTY COMPAN]T If you have any lnqulllc or reqrrlre further asststence, please conted onc of the numbers bdow: For Closlng Asslstanct:f,'or Tltle Assistarrc: Vail Titlc Dept. Rogcr Avila t08 s. FROMAGBRD. W. #203 P.O. BOX 357 VAIL, CO 8t657 Phonc:9t0476425L Fex': 97O4164534 EMall: ravila@ltgo.con ESTIMATE OT T]r[E FEES Infomation Bindcr 917s.00 TOTAT t77s.00 TSANK YOU I.()R YOUR ORDERT .tAN-30-Ol t5:47 FROM:LAND TITLE GUARANTEE tD, r 9704 764 5 34 PACE 3 --Iv- Chicago Title Insrnuco Comprny ALTA COMMITMENT Schedule A hoperty A,ildrs: LOT 15, VAIL VALLEY, TIIIRD FILING l. EftecclveDnte )anury 19,2OOlar5:00P.M, 2. Pollcy to bc Istucd, and Proposed Insured: Infomation Bindct Proposod krsurt& TO BE DETERMINED Our Order No. Vnl$l Gwt.Rd.: 3. Tha estete or intcrcst in thc lrnd dccribed or referred to ln thts Comrnitment errd coYcred hcreln lsl A Fee Simple 4, Tttlo to tho est.te or toteftal coverod berdn ls rt thc effccitve drtE hereof vcstcd in: SNOWSTORM LIrc, A DEL.{WARE LIMITED LIABIUTY COMPA}IY 5. fbe hnd rtfcrred to In this Connltnent ls descrlbed as follours: LOT 15, vAlL Vr{L:LEY THIRD FILING, ACCORDING TO TllF PLAT RECORDED AUGUST 30, lW IN BOOK 259 AT PAGE 69, EOUNTY OF EAGLE. STATE OF COLORADO, .rAN-30-Ot 1s,{7 oo ALTA COMMITMENT ScheduleB-Sectionl (Requlnncnts) Our ftder No' VnMSl The followlng are the reqrdrcurarts to be complleil wtth: Itcn (a) Payment to or for &p accannt of tte gnators or mort8aSors of thc firll coosideration for Oc 6tetc or iotrest to bo i!6u$d heo (b) Proper iosmrmeot(s) crcadog hc cshtc or iDtfllst to be insnrcd mrst be executcd ald duly 6lsd for rccold, to-wit: Itnr (c) Payncnr of all taxes, shargcs or asccssootrb lovied anrl ascse<l agdnst rhe subiect prcotscs cAic.h are &e rdpayable. Itcn (d) Additional ttqufu€nens, if any discloseilbelow: ftIIS COMMITMENT IS FOR TNFORMATION ONLY, A}-ID NO POLICY WILL EE ISSUED PURSUANTHERBTO. FROU' LAND TITLE GUARANTEE ID, r 3 7O4 764 s34 PAGE 4 JAN-3O-OI t5:47 FROM:LAND TITLE GUARANTEE lD, 19704 764534 FAGE 5-a ALTA COMMITMENT ScbaluleB.Sccdon2 @rqtions) (hr0t&rNo. vz7l81 The poltcy or poltdee to be issuoil will cordrin exceptiorc to ttrc followlng unlccs the samc ar€ dis.Eosed of to thc satirfactirm of thc Company: l. Ritbn or clains of garties in posession tror showtr by thc public rccords. 2. Fascrncots, or crdns of cascocrus, Dor showl by thc puDlic records. 3. Discrcpmcics, conllics in bounrlrry lincs, shotrge h area, eDcroacbmdlts, ard any faots which a cofiect srney md inspcction of thc prtoiscs *outl disclooe asl vhitt are aot $lo$rq Dy 6e lublic rccords. 4, Aqy lig!, or rigtt to a lieo, fgr services, l$or or mdetial tteraofore or hercsfrer fiunished' inpost*l by bw an<l aot $rownby tbe public recoral$, 5. Defocts, lieos encombrmcas, atlwrsc rlaim< 6r other mettcrs, if eny, crcatsd, first appcaring b tbc public n*utls or attrc|ing subsequmt ro rhe cffecdvc <lrtc bctcof bur prior to tbe date the proposcd insurul acquircs of record for rahrc thc estate or htcrcst or mongagc thereon covertd by lhis e@mitnrent. 6. Taxrs or rpecial a-sessnrcnu which err not showtr as e)dsti[g lieDs by the pnblic records.o thq Trcasurcr's olfice. 7 . Ueos for uryell weter atrd sewgr ghgf8cs, if rly.. 8, In edditim, tfp ownar's p,oltcy vilt bc srbject to thc urortgegc, if ary, noted in Section I of Sc}cdule B hueof. 9. RIOITI OF PROPRIETOR OF A VEIN OR LODE TO EXTRACT AND REMOVE I{IS ORE THEREPROM SHOUI' TTTE SAMti BB FOUND TO PENETRATE OR INTERSECT TTTE PREMISFS AS RESBRVED IN UNTTBD STATES PATENT RBCORDED.N.INE 29, 190.3, IN BOOK 48 AT PAGB 495, 10. RESTRICTI\TE COVENAT.ITS WHICH DO NOT CONTAIN A FORFBJTURB OR RBVERTER CLAUSB' BUT OMITTING ANT COVENAM' OR RESTNCTION BASED ON RACE, COLOR, RELIGION' SE?(, HANDICAP, FATdILIAL STATUS OR NATIONAL ONOIN IJNIJSS AND ONLY TO T}IE EXTENTTIIAT SAID CovEI{aIT (A) ISEXEMPTUNDEII CHAPTER42, SECTION 3697 OF T}IE IINTTTD STATES CODB OR (B) RELAT}jS TO HA}.IDICAP BUT DOES NOT DNCRTMINAI3 AGAINST HANDICAP PER.SONS, AS CONTAINED IN INSTRUMENT RBCORDED AUGUST 30, 1977. IN EOOK 259 AT PAGE 68. I I. UTILITY EASBMENT AS GRANTFD TO VAn- WATER AND SAI'IITATION DISIRICT IN INSTRI'MENT RECORDED TEBRUARY 5. 1969. IN DOOK 2I4 AT PACE 612 AND RBCORDED ocToBBR 20, 1969 IN BOOK 216 AT PAOE 217- 12. UNDMDBD I/2 INIEREST IN AI.ID TO ALL OF TTIE GAS, OIL AND OTHBR MINERALS' SOLTD UQUID AT.ID GASEOUS, OF EVERY KTND AND NATURE, INCLUDING URANI'UM' IN oN AND tTNoTn nNY AND wI{lcII MAY BE PRODUCBD FROM tT{AT PORTION OF STJBJECT PROPBRTY IN SBCTION IO OF LIiGALDBSCRITTTON HERETO AS EXPECTBD AND '.tAN-30-Or l5:4? FROM:LAND TItLE GUARANTEE rD: r9?o4?64534 -.v|} PAGE B ALTA COMMITMBNT Sc.hcttule B - Scction 2 @rceptlor) OurorderNo- Vnl$l Thc policy or polldcc to be bued will contaln orccptlons to the following ualess the sarne are dlspo*d of to the setlcfaCion of thc Compary: RESERVED BY PBTER E. XATSOS IN DEBb RBCORDED MAY 3, 1960 IN BOOK 165 AT PAGElTI. 13. UTTLITY EASCMBNT ALONG TIIE SOUTI{WBSTERLY, SOUT}IEASTERLY AND NORTI{EASTBRLY I'T UNBS OFSUBIECT PROPBRTY AS SHOWN ON TIIE PLAT OFVAILVALLETTHIRD FILING. 14. DRAINAGE EASEMENT ?.5 FBET ALONG TIIB NOBTI{WFSTERLY I,OT LTNE OF SUBJEqT PROPERTYAS SIIOTiIN ON TI{ERBCORDED PI.AT OFVATL VAIIEYTTIIRD FILING. PAGE ?JAN-3O-A1 1S:47 FROM= LAND TITLE GUARANTEE ID=79?''4764534 t- It LAND TITLE GUARANTEE COMPANY DTSCLOSURP STATEIVTETTT Required by CR-S, 1.G11-f22 A) Tte subjecr red property may b€ tocated in a special hxiDg district- B) A Cenificate of Taxes Duc listiog each taxing jurisdiction rnay be obuinerl ftonn the Counry Treasurcr's authorized agent- C) The infomation rcgara;ttg qpecid disiricts and the boundaries trf sucb disricts may be obtained ftom the Boaril of County Comnissioucrs, the Counry Clerk and Rccorder, or the Cwnty Assessor. Effective September l, 1997 , CRS 3@1tr406 requires that aU docrm€Nlts Fceiveal for recordi4g or 6ling in thc clerk and recorder's office shall conhin a top margin of at lrut orrc inch and a left' rigbt and bottom margin of at lease onp half of an inch- The clerk and reconilcr may refirse to record <rr file aly document that does not conform, excqlt tbat, the reqnire,ment for the top nargin sbalt not apply to documqnt$ using forns on which space is providcd f<rr rccording or filing information at the top m:argin of the document, NotF: Colorrdo Divisiqn of lruuratrce Regulrtions 3-5-1, Pangraph C of Anicle YII requircs tbat "Every title enrity shall !9 rcsponsible for alt nafiers uibich appear of recor.rl prior to the time of recording wheoever the title entity con<Iucts tbe closiog and is nlqponsibte for recording or filing of legal dorrrmeats resultirg from rhe transaction which was closed". Provided that l,and Titlc Gurantce Conpany conducts the closiog of the insuted transaction an4 is reslnnsible for recording tte legal ilocuments Aom the tra[saction, exception nrorbec 5 will Dot ippear on the Oqrner's Title Policy and the Le.nders Policy whcn issucd. Notg Affirmativs mcabauic'y lierr prolecrion for the Owrer may be arrailablc(typieally by deletion of Exccption no. 4 of Schedule B, Sectioa 2 of the Commiment from rhe Owner's Policy to be issued) upon compliarce with the following conditioD.s: A. Tbe land dcscribcd in Schedule A of ttris cor"rnitment rmret be a siogle family resideuce which incluiles a condominium or townhouse unit. B. Nu labor or Dalcdals havc bccn firrnishctl by mechanics or matcrial-meo for purposes of conshrctiotr oo the laod described in Sc}erlule A of rhis Coumihnent withtn the past 6 molths. C. The Coopany mu6t receive an appropriate affidavit inrlunlifyirg tbe Conpany against un-filed meclnnic's and matcrial-meil's licns. D- The Company rnust receive paymenc of thc appro'priate premium. E. U there has been conshucblou, improvemenE or major relairs undertaken on tbe property to hc prrchased witlrin 51 poo6r pnor lo (he Date of the CommiuDed, the rcguirE, cots to obtaitr covcr4ge for unrecorded liens will includc: disclosrue of certain cotrsmtcrioD iDfom:ation; financial infounadon a.s to the seller, the buitdsr an<l cx the contraqor; paymenr of the appropriate prunium fully executed Indemniry Agreemcnts satisfactory to the comPany, and, aay additional rcquircmenls {s rtray be necessary atier an exemilatiou of the aforesaid inftnratiou by the Company. No cover:rge will lr given under atry oirgumstances for labor or naterigl lbr which the inzured has conrractecl fur or agrved to pay. Nothirg hereia contarned will be deamat to obligace the qxnpury to provide any of thc qovcragcs referred to herein unless thc abuve conrlitions arc fully sati.sfied' Plqzq-Ilong" With ifs innovqfive, cobbled surfoce lexture, Plozo-Slone recreotes the noturol hond-hewn effect of old-world Europeon segmentol poving. Composed of six different shopes, Plozo-Stone permils fhe creqtion of circles, holf- circles, fons, curves, geometric ond rondom pqtterns thot unify ond enhonce londscqpe ond orchitecfurol elements with beoutifully flowing designs. Plozo-Stone frees lhe imoginqtion to use lorge-scole pqtterns to creote inlerest ond dromo in londscqpe setlings to hormonize poved oreos with sunounding buildings ond to lend design distinclion to ony project, Compoalllon ond llonulqclure Plozo-Slone is mode from o "no slumo" concrete mk. Mode under extreme pressure ond high frequency Mbrqiions, Plozo-Stone hos o compressive strengrth greoter fhon 8000psi, o wofer obsorption moximum of 5% ond will meel or exceed ASTM C-936 ond freeze- thow testing per seciion 8 of ASTM C-67, lYplcql Cross Secllon of Concrele Fover Inslqllolion t Dimenslons :p+tNDM M\X/ Smoll Rectongle Stone l40mm x 70mm (5112" x23l4"l Lorge Circle Stone I 40mm x 82mm (5 I /2" x Wedge) Smoll Circle Stone l40mm x I l9mm (5 1/2"x Wedge PAVER 'I' SAND COI\4PACTED AGGREGATE COMPACTED SUBGRADE a @c l40mm x 21Omm (5 l/2" x 8 1/4') Squore Stone l40mmx l40mm (5 112"x5112") Medium Rectongle Stone l40mm x l05mqn (5 112" x4118") edb Applicqllons:. Drivewoys . Poiios . Enlronce Aleos ' SidewolK ' P decks . Gorden Pqlhs . Terroces . Beoch Promenod . Pedestriqn Molls . Roof Gordens Nolor Colols ore shown os occurdtev os possidg In brochures ond sornpbs, blt due lio noiurs of the prodrict drd vorltbles In r€produciion, colors rnoy not rnolch exoc|. Fo( i rqsllls h mohloking co*c. consisl€ncy, pove6 musi be insl'C€d florn sgr'elolcl-b6 ot o E ior€6cence, o \ahitish, powrbr{ke deposil, .noy opp€or on concrele powls. lhls is o r occurence In orry concrel€ goducl ond will usuolly w€or off o\€r lime, Somple Inslollolion Pqtlerns Potlens ore nol shorvn to scole, MANUFACTURERS OF m,, CONCRETE PAVERS SALES OFFICES: 1-800-245-PAVE (NationaD . 1-800"580-PAVE (T€xas Only) DALLAS,/FI. WORTH, TX (817) 481-5802 LASVEGAS, NV (1@) 22 (281) 391-7283 PHOENIX, AZ (602) 25 (303) 287-3700 CTNCTNNATI, OH (s13) 47 (318) 234-8312 KANSAS CITY, MO (816) 52 NEW ORLEANS, LA (504) 882-9111 CHATTANOOGA, TN (423) 85 sAN ANTONIO TX 15121 56R-7243 HOUSTON, TX DENVER, CO LAFAYETTE, LA CONCRETE BEAUry oa{ Oo6c!;(odc!-or s>.\o >(ua> r- Cal_ f, .9 OJ:ul OJ o JJ 3o UJ J t],.l JaF uJo z tr UJa TU(Jz IUo (n IUt \zz I lg=5**gfg E. f ! fE FgJf; 9e2;3 HI .F;g;g H s s ;: Ersr rE F= t1E # ? E ll eT H".9 F ; Jge \zv = t zF =, UEA r-'p d XafrPE:Ji s5s 3g ?EAv XUEa ra;F Egg-* EE:gF hpii I! =93=J uJ(/|C)CC oj da ur:u= a E:Pfr X =,tbt fr lo,dFs E =o =!J E rH9iA v r!uaz = '-r u) (J>i-r PEE #3gHEA2s AqHJ 8e=?2 pEg= o-cD<(, J.^ J,^3 1Z EZ n; EPE EE E 2 €,,, lqd ld E P5= ro=cc o-d Fo- r.n PB i=H 3E Si EEE? =24 3U =? Ugrh E8> 5> vd df ,lolo-lJI HIFI:lto.ll Jl f;lol 2lol Fl9(Jl-ujlrl 'lu \-/ .l fil Fl B I I *l -Jl631FEI iu fu HH (. )X o \--,"ulF a a-l./lOuJoFE = ?st q * i;0,"v j 5fi@F t" I = 6 H FR F 3 ; S TJ f; o -r9ig =6 E6 dea = 3 Ei6qd e fr 62= lt F o- ><= :28 l g EH 863 * =v =H q- -it 't- o N ll (J o- F &. UJ o L) =lJ.tz 3 Fr/) CL Juttut-6 (9z tr x t,lJ z oo 5(J E IJJ (J = = td. .-E * FF0tn ;g i!= =258 (L ui r./.1I(J Our<d odP H/'\ (J uJ Xs E>6 H rn ]U =e s65 =XF III LJJ t-/.t Z. zoaI(J z tr !1x uJ u9ztro>t-<(n o- z Eozo E F 2otr UJ tr T Eoz -o -o o = ll 4 Denve, Sttdarcl Paver Cfitrc DARK BROWN LIGHT BROWN PEWTER ffi oa -:-. .^: !{ ,..-, =.:1, ., r- '- -! ._-r --JJ \I i 1 r\ 4, E >&, -=9LJ-,| < -= = ;-l'-- =pEsE< e.- < :i' ,..r-i> 4o =2.>=-c<=coova -, .^ === ==E<et'< - -.J |',Ll , -,-=9r.r-l < -= =F,!G -<Itslcqu.i =e,- i -o -.o* o,' -. 'r 4 a-, rl ^t{ Yrebb ,trr'hrIe(II P( l1Ar,ll( Rtllt]Efl(E 1009 llJt{BURll DRlfi, fAlL t)(lllnlG DRlft --) =.J -1:s Z- 4=6k- f..Lt )' - \/t -tE '.< 3E.-:ue. U4 -= =BEq< O xY - a-{ 4) .Z- L9 -. 4E =3= \-7 d= aE -. --o -.,= € '.: .E TIPUtt YJIII| ttv{ GuSI llltfllc k.h.webb arthrre(tt.p( HAltt RttlDtiltt 1009 t|JilBURSI DRlft, vAlL 9ourH ELalfrftoN .J = ,-at>4 4,F6=rlr i-- == 4l\ \ :E-)E3=,t - ti- =gtP< er )< \\-rI a..r re-l rr, -o€ o.j>,= -.J =.-J =A4, (J6tr5r- =2. .?llJ = - --u) -:=vE ,/t =F = = =9 a* qr --o --o € r:U rE . I I I *i I I I TL F6' [iko _?. + .. i" dffil,,frff' L f,!""t " l.-:rn"l ! "i4'; i !,,,t: t' : ii' "r'":. 4 .'\*.. ' ,.: , i;"j't,ir {" . ;; 'ra t**' st" .E{i. a "i :- ' I.t . * .e n f,.;tt'i .,i, ' 't '. ::.L ' , *'i* .'-t.:",#.," I l t4 jff tl a', ffi l{ !e'i 1. " ti i .4 . 'li,l, ,,,ri t! * .. , 1- I II I Iul I Irl lJ- F<U' ,l I I I IJNol .olNl r-l'l rii ko otf IL o_.\ ll t.L F U) 3 LU I.IJEz(, gJ slro ** +:t*'i ** *,1,$* ****t * * * ** +** ** * * * ****rt* ** * l.'***'l** * *** * * *'t**** ***:1.{.:t'}*+* * * *+***** * '1.**+****** * * ** TOWN OF VAIL, COLORADO Statement ** * * * * * + * * * * * * * * * * * * *+* ************ * *** ******* *'i*** * * * * * +* * '! ** {.l. * ** * * * '} ** *,1ti ** * * * ** * * * ** * * * * statement Nuniber: R000003217 AmounE: $20.00 Lo/04/2oo2o4:48 PM Pa)ment. Method: Check IniE: .IAR Notation: 3004 KH Webb Architects Permit No: DR8020363 q4)e: DRB-Minor Alt,SFR/DUP Parcel No: 2LO1LO2O10O2 Site Address: 2009 SI'NBURST DR VAIL Location I Total Fees: $20.00 This Payment: $20.00 Total Al,Ir Plnta: $20.00 Balance: $0.00 *************+**ri ***+***+* + +* + * **++ + * + ++ * * * *l** **'i**+***++***********{.++*+***+*****+*****+*+ ACCOUNT ITEM LIST: Account Code Descrjptjon Curnent Pmts DR OO1OOOO31122OO DES]GN REVIEI,{ FEES 20.00 r Design Review Board ACTION FORM Deparbnent of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2L39 f ax: 970.479.2452 web: www,ci,vail.co.us Proiect Name: Snowstorm LLC Residence DRB Number: DR8020237 Project Description: Install air conditioner compreasor on west side under overhang (same as east side) Pafticipants: OWNER SNOWSTORM LLC 0712212002 Phone: C/OTURCAN CONNELLWS ATTN: RF SALTIRE CT 20 CASTLE TERMCE, EDINBURGH EH1 2ET, SCOTLAND License: APPUCANT Nedbo @nstruction 0il2212002 Phone: 845-1001 Tom Box 3419 Vail, CO Nedbovail@aol.com 81657 License: Project Address: 2009 SUNBURST DR VAIL Location: west side Legal Description: lot: 15 Block SuMivision: VAIL VALfEY 3RD FILING Parcel Number: 210110201002 Comments: See Conditions Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION Action: APPROVED Date of Approvall. O7 12612002 Cond: 8 (PLAN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond:0 (P|-AN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: CON0005443 Location of air conditioning unit shall be as far under the house as the unit size allows Pranner: A,rrnttil''o,. ttlg DRB Fee Paid: $2O.OO Application for Design Review Deparunent of Community Dwelopment 75 South Frontage Road, Vail, Colorado 81657 tef : 970,,179.2139 taxi 970.479.2452 web: www.ci.vail.co.us General InformaUon: All projects requiring design review must receive approval prior to submitting a building pennit application. Please refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design review approval lapses unlacc a building permit is issued and construction commenes within one year of the approval. Location of the Proposal: Lot: / f Block:_ Subdivision: PhysicalAddressr 4rO? {v-woctLrf 1 '. Parcel No.: ? lO I I Aa o/oOZ, (ContactEagleCo.AssessoratgT0-328-8640forparcel no.) + Name(s) of owner(s): S l,o,w Sfoa-n ,(-LC Mailing Address: E Owner(s) Signature(s): Name of Applicant: Mailing Address: E-mail Address:rax: FV.f -%r Type of Review and Fee! tr Signs $50 Plus $1.00 per square foot oftotal sign area. No fue $650 For construction of a new building or demo/rebuild. $300 For an addition where square footage is added to any residential or commercial building (includes 250 additions & interior conversions). $250 For minor changes to buildings and site improvements, such as, reroofing, painting, r/indow additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvemenB, such as, reroofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For revisions to plans already approved by Design Review Board. No Fee TOI4'NM {7/ 3{ry ! n tr tr 7 tr tr Conceptual Review New Construction Addifon Minor Alteration (multFfamily/commercial) Minor Alteration (si ngle-family/duplex) Changes to Approved Plans Separation Request Planning Staff or the RECEIVED For Office Use OnlvriJ t-i'i, ---i4 I"" cnecx no.: P3* & { ay. ** '+ * + * * + + t * * * * t* t * t* * * {, * ** a * * * t + + ** *+ * * +**+t,**r!***tt** +* **+*+***+**ti *,irrt {. *,* ** + i * t l * t * + * *TOWN OF VAIL, COLORADO starement*+f '* 't*ti**+***+****'t+****** + **t******+*t***t*i******tf*******+*{.*+r++***rt***************+** StatemenE Number: ROOOOO2?70 Amoun! 3 g20.00 07/22/2OO2O2:28 pNIPa)ment Method: Check Init,: JAR Notation: 22288 Nedbo permiE No: DRBO20237 Type: DRB_Minor ALt,SFR/DUPparcel No: Z 1O t 102 O 1OO2Site Address: 2009 SuNBt RST DR VAILLocation: urest side $20.00 Total Fees: TOTA1 AIJI' PMtE : +{' ***1**'t****+***r****+**********+1********+**+*********.*.****l?*tfrii***.******r*$*?;3*o--"*- ACCOIJNTITEM LIST: Thls payment 3 Account Code DR 00100003112200 Docnni nf i nn DESIGN REVIE|,\l FEES $20. oo $20.00 Cur^r'ent Pmts 20. 00 ,r-#) Design Review Board ACTION FORM Departrnent of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2L39 fax: 970.479.2452 web: www.ci.vail.co.us Proiect Name: Snowstorm LLC Residence DRB Numbert DRB02O222 Project Description: Install air conditioner compressor on east side under overhang Participants: OWNER SNOWSTORM LLC 0208/2002 Phone: C/OTURCAN CONNELLWS ATTN: RF SALTIRE CT 20 CASTLE TERMCE, EDINBURGH EHl 2ET, SCOTI-AND License: APPUCANT NedboConstruction 0710812002 Phone:845-1001 Tom Box 3419 Vail, CO Nedbovail@aol.com 81657 License: Project Addressr 2009 SUNBURST DR VAIL Location: Legal Description: Lot: 15 Block Subdivision: VAIL VALLEY 3RD FILING Parcel Number: 210110201002 Comments: See Conditions BOARD/STAFF ACIION Motion By: Actionr STAFFAPR Second By:vote: DateofApprovalt O7/IO/20A2 CondiUons: Cond:8 (P|-AN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: CON0005417 Approved per plans submitted Planner: George Ruther DRB Fee Paid: $2O.OO ,,*ffi Description of the Request: Application for Design Review Department of Community Development ZS Sor'rtt' Frontage Road, Vail, Colorado 81557 tel 970.479'2t39 fax]. 97Q.479.2452 web: www.ci.vail.co.us General Information: All projects requiring design review must receive approval prior to submifting a building permit application' Please refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Departrnent'. The pqect may also need to U.'r.iri.*.6 by the Town Council and/or the Planning and Environmental C'mmission' Design review approval tapses untess a building permit is'issued and construction commences within one year of the aPProval' Location of the Proposal: Lot:- D-Block: Physical Addressl (Contact Eagle Co. Assessor at 970-328-8640 for parcel no') Azonangr KzS ./ / . 5t0tr Name(s) of Owner(s): Mailing Address: Mailing Address: Owner(s) Signature(s): Name of Applicant: E-maif Addresst/W Type of Review and Fee: E Signs E Conceptual Review tr New Construction tr Addition fl Minor Alteration (mu lti-fa mi lylcommercial) Minor Alteration (single-family/duPlex) Changes to Approved Plans Separation Request $50 Plus $1'00 per square foot of total sign area' No Fee $6s0 $300 $2s0 $20 For construction of a new building or demo/rebuild' For an addition where square footage is added to any residential or lorr"r.ijf building (includes 250 additions & interior conversions)' ioi .inot .hungesio buildings and site improvements, such as' ,ur*Rng, palriting, window additions, landscaping, fences and retaining walls, etc. For min6r changes to buildings and site improvements' such as' ;;";frs, -piiniing, window additions, landscaping, fences and n tr retaining walls, etc. $20 ioi r"uitiont io plans already approved by Planning Staff or the Design Review Board. No Fee No.: For Office Use OnlY: i." piij i-- ao.--.--- check No.t A e p6 { i xz' *'l (U,<eent P?t'/('/o.*trd4tD Gd UvUOzR O UZe ,t/'4il e 4F o.- f,ouse ( uugtz ,ce-TPa'*T or= Ho"lsz S ft]sr goc I TOWN OF VAIL DESIGN HEVIEW STAFF APPROVAL 0Ft|*z rfat F.a*', Lauo o<trut2 TOWN OF VAIL DESIGN REVIEW STAFF APPROVAL \ -1. t- \e66. 07llo /oZ Pe<f- &-tt- \6/ O^,4)lf ousc ATSTAFF:---&.; *,t**t**,**a**|.*+*tr****|t ****+** ***t*+ ********** *'l********** * * ***{r ** ***f{"r{'**'}* * fr** **r* +**t* TOWN OF VAIL, COLORADO -r*ar*,,r* statement ***a****{,** +r*******t* rrIa-**,r+*+**+r'**+*+*** **++*r****+*+f* tt*+{t't+*+*f+*r***rl*r**i++***+'ff statement Nutnber: ROOOO026S4 Amount: $20'OO 01 /08/2OO2LL:27 ltr'tl Palrment, MeEhod: Check IniE: iIAR Notation: 22255 Nedbo congtruction permit No: DRBO2O222 Type: DRB-Minor Alt' SFR/DUP Parcel No: 210110201002 SiLe Address: 2009 SttNBURgT DR VA'lIr Location:Toual Feea : Total ALIJ PmEs 3 Balance : 920 . oo 920.00 so. o0This Payment:$20.00 **********it********t**|.|*|+*'**+****|************{.******'*f't**t**}t.*'+********f****+'r***+**** ACCOI.]NT ITEM LIST: Account Code Descri Pti on Cur"rent Pmts DR 00100003112200 DESIGN REVIEi^I FEES 20.00 TOWN OF VAIL 7J S. FRONTACEROAD VAIL. CO 81657 970479-2t38 OO DEPARTMENT OF C.MMUNMVEL.PMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT SFR BUILD PERMIT Permit #: 802-021I Job Address: 2039 SLINBURST DR VAIL Location.....: 2039 SUNBURST DR Parcel No...: 2101 10201 009 Project No : or{NER PIERCE, MARTTTA 0't/05/2002 phone: PO BOX 1123 VAIL CO 81558 License: coMrRAcToR NEDBO CONSTRUCTION 07/O5/2OO2 phone: P.O. BOX 3419 VAfIr, CO 8165I I-,icense: 251-A APPIJICA]iT| NEDBO CONSTRUCTION 07/05/2oo2 Phone: 970-845-1001 P.O. BOX 3419 VAIL, CO 81658 License: Description: INTERfOR REMODELT: MASTER BEDROOM/BATH ITOWER ITEVERL BATHS,DRYWAIL PAINI,CARPET NEW BOII.JER Occupancy: R3 Single Family Residence Type Construction: VN Type VNon-Rated Valuation: $225,000.00 Add Sq Ft: 0 Fireplace Information: Resficted: Y # ofGas Appliances: 0 # ofCas Logs; 0 # of Wood Pellet 0 *..**.*.|..l.||,||.||+r*ll't.||*|t|1'.*'**||*.'.1*1*..|'}':t**|.*,|*,|.*|t.|FEESUMMY Building--> 51,240.00 Restuarant Plan Review-> $0.00 Total Calculsted Fees-> 52,049.00 Plan Check--> 5806 . OO DRB Fee------> SO. OO Additional Fecs--..-_> S0 .00 lnvestigation-> gO . OO Recreation F€€-*> SO. oo Total Permit Fec-_-> 52, 049.00 Will Call-> S3 . OO Clean-up Depnsit---> S0. 00 Paymens---> 92, 049. o0 TOTAL FEES-_--> S2, 049 - oo BALANCE DUE--> SO. O0 * tt rtl**'l tt 'la t:tll Approvals: IECM: O51OO BUIIJDING DEPARTMENT o8/o2/2oo2 ccD Action: AP ftem: 05400 PLANNING DEPARTMEIflI It,CM: O55OO FIRE DEPARTMENT Item: 05500 PITBI-,IC WORKS See page 2 of this Document for any conditions that may apply to this permit. tJrt-,{.!^..(U\a Status...: ISSUED Applied. . : 07/0512002 Issued...: 08/06/2002 Expires...: 02102/2003 PACE 2 '|t{.***+*****{t**,t'|'*{t,|.***'.+,t.4',tt*{t*i'***{.***{t*,lt'tf'*****'}**{t*'|t***+:i***+{.,|t:l!lt,********** CONDITIONS OF APPROVAL Permit #: 802-0211 as of 08-062002 Status: ISSUED +*****+***+{t,}*:t**'*l':f********l'*,},*********{t{'t|t,t.**********,i,|t*++**{.*d'*,|t*'|t{'*'|t***'*******1,t****'t**tttt,}{':t******** Permit Type: ADD/ALT SFR BIIILD PERMIT Applied: 07/05n002 Applicant: NEDBO CONSTRUCTION Issued: 08/0612002970-845-1001 To Exoire: 02/02/2003 Job Address: 2039 SUNBLJRST DR VAIL Location: 2039 SLJNBURST DR ParcelNo: 210110201009 Description: INTERIOR REMODEL: MASTER BEDROOIWBATH LOWER LEVERL BATHS,DRYWALL PAINT.CARPET NEW BOILER '|t'|tlt*:|.{.*******'|t{.'|t**********|''i*{.'|.***{.***'|t+:|'*'|{.*{.*{'+'ttConditions*{.'|t{'!t.:***|*+*{.***l'******** Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: l6 (BLDG.): SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS AND EVERY STORY AS PER SEC.3IO.6.I OF THE 1997 UBC. Cond: CON0005471 oo oo DECLARATIONS I hereby acknowledge that I have read this application, filted out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply witlr the information and plot plan, to comply with all Town ordinances and state laws, and to build this strucfure according to the towls zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOI.JR HOURS IN ADVANCE BY Send Clean-up Deposit To: N/A T 479.2 I 3 8 OR AT OUR OFFICE CTOR FOR HIMSELF AND O ff:oo ev -: ru bo oo oo *****+*+*******++*******f*********f***t+*****,iti*'l****l**'i********{.*:t++f:t **+{.* *** * * ** * l.* *+ ** TOWN OF VAIL, COLORADO Srat€ment **t**********************,1******+t***t*.it '! l+ !i *f * ****** ** * '1. *ti+*{.:l * **** * **** ** '} ***********+*** Statement Nurnber: R000002843 Alnount': $2,O49.00 Oe/06/200209:45 AM Pal.ment. Method : Check IniE : JAR Notation: 22603 Nedbo Permit No: 802-0211 l!4re: ADD/AL,T SFR BUfLD PERMIT Parcel No: 2101102 010 0 9 Si.te AddreEe: 2039 SUNBI'RST DR VAII IJocation: 2039 SIJNBURST DR Total Fees: S2, 049.00 This Payment: $2,049.00 ToEal ALL Pnts: $2,049.00 Balance: $0.00 *+ ****+* ** * + * * + * * * * * * * * * * * * * * * * * t * * **** ** *t*** | lf **t* *** *{.*+l*t**tt+* +t* * * ** * * *r * * * ** * * * ** +* ACCOUNT ITEM LIST: Account Code Descr"iption Cur^nent Pmts BP OO1OOOO31111OO BUILD]NG PERMIT FEES 1.240.00 PF 00100003112300 PLAN CHECK FEES 806.00 t,lc OO1OOOO31128OO WILL CALL INSPECTION FEE 3.OO I CONTRACTOR INFC'RMATION General Contractor:Town of Vail Reg. No.: APPLI MWNOPVi,IL 75 S. Frontage Rd. Vail, Golorado 81657 PLETE VALUATIONS FOR BUILDING PERMIT (LAbOT & MAtCTiAIS BUTLDTNG: $ /5A,ooo ELECTRICAL: $ ?o oo,t OTHER: $ PLUMBING: $ 30, ao.r MECHANICAL: $?5 oo u TOTAL: $ JobAddressr 2o3? ,fctaJ4'tz-sf ty'4t' ' 7o ttes:7Job Name: A)t.Uffu;( S 7-A2.r'1 Subdivaslon: f4/( Phon", /??_1€3owne rs Nu^"'c(r, -vrr r.L &u'r*t- L L c -at z EZ r a<- /(6.ut o.2tZc-z,/eL 447rqs D4/ ctt t<1 f)4,44, C.f /Ud--r' 4al <*. WorkClass: New() Addition( ) Remodel()d Repair( ) Demo( ) Other( ) Does an EHU exist at this location: Yes ( ) No 0OWork Type: Interior S<t Exterior ( ) Both ( ) Type of Bldg.: Single-family ( ) Two-family ( >f\ Multi-family ( ) Commercial ( ) Restaunnt ( ) Other ( ) No, of Accommodation Units in this building: 3No. of Existing Dwelling Units in this building: : Gas Apoliances ( ) Gas Wood Burninq ( / Gas Loqs ( ) Wood/Pellet ( ) Wood Burninq (NOT ALLOWED Does a Fire Sprinkler Systenl-Exis{: Yes ( ) NoDoes a Fire Alarm Exist: Yes $Q No ( ) For Parcel # Contact * * * **'* * * ** * * * ** * ** * * * * * * ** *** * * * ** * * r, * FOR OFFICE USE Assessrc Offie at 970-328-8640 or visit *****L************** F:/everyon4forms/bldgperm ic\* P.3 Town of Vall U OFFICE COPY I a ll ls[estos fe*ing and Gonsulting fohn f,. Peterman 0to PO Box 1230 0 Cliftoru CO 81520-L230 Phone 970-270-3689 I Home Phone 97046+5265 INSPECTION REPORT PREPARED FOR: NEDBOCONSTRUCTiON P.O. BOX 3419 VAIL, CO 81658 ATTN: TOM LOCATION: 20398 WinterStorm VarL CO REPORT PREPARED BY: JohnR. Peterman Inspector Manager Cenifrcate No. 66OI Jul OZ O? 12:lSp P.4 A & D Asbestos Testing and Consulting ]ohn R. Peterman Asbestos Testing Proiect Design and Consulting IrO Box 1230 Clifton, CO 81520-1230 Cell Phonq 97A-Z7O-389 Home Phone : 97Q464-5265 INTRODUCTION: On .Iune 28,2002, an inspection/survcy was conducted and 5 bulk samples were collected from the: RESIDENCE 20398 Winter Storm Vail. CO The purpose of the inspectiorlsurvey was to locate and sample suspected asbestos containing materials that might be present in the unit that is plarured for renovation. The inspection was made and the samples were collected by John R- Peterman, an A.H.E.R.A. and State of Colorado Certified Building lnspeclor. Great care was taken during the inspection and sampling to be as accurate as possible. It should be noted that minimal damage was done to the existing building structures during the inspection so there is no documentation ior unseen conditions or stored items. All samples *.ere analyzed by DCM Science Lab in Lakewood, Colorado- This laboratory is deemed '?roficient" in the E.P.A. Qualit5. Assurance (QA) program for the determination of asbestos in bulk materials, and is accreditcd by the American Hyg:ene Association (AHA)- SAMPLING PROTOCOL: A random sampli:rg scheme was used to sample the suspect materials that were discovered- If during any future demolition or renovation work suspect material is discovered that hasn't been sampl ed and would be disturbed, work should be halted until the material has been tested. oo lo P.s RENOVATION A REA DESCRIPTION: The inspection/suwey on 20398 Winter Storm was limited to renovation areas inside the building. 'fhe exterior is not planned for renovation and *'as not inspected' The interior walls are "olr"."J with sheet rock with iight t"*tot" and wood T-1-11 type sheet material' 'fhe ceilings are covercd with sheet rock with fignt texture like the walls. The floors are wood througlrout with no covering and ceramic tiles. The heating is provided by base board heat and fireplace' No suspect marerials were visible on the heating systern in the renovation area. CONCLUSTONS ANI) RF"COMMF'.NNATIONS: Laboratory Analysis of the bulk samples indicate that no asbestos was detected in the submitted bulk sarnples. Jul OZ Oa LAiJ-xP SAMPLELOCATIONSFORSURVEYCOMPLETEDON:J1lne^8,n00n p.6 FriY/N N N N N N Sampte # Area SamPled From WSB401 DiningRoom/KitchenWall2ndFloor WgB-002 UPstairs BedroomWall WgB003 UPstairsToP of Stairs WaIl WgB-004 Downstairs Hallway Outside Batlroom Wall WgB-005 Downstairs Under Stairs Storage Wail Description Composite Sheetrock w/ LightTexture Composite Sheetrock w/ LightTexture Composite Sheetrock w/ LightTexture Composite Sheetrock w/ LightTexture Cornposite Sheetrock w/ LightTexture Jul 02 O2 12:19p SAMPLE RESLILTS Sample # ws-8401 wgB402 wS-B403 w98004 w9B-005 KEY: NAD: No Asbestos Detected COLLECTTON DATE:lyne-Z8,2402 p.7 Description Composite Sheetrock w/Light Texture Cornposite Sheetrock w/Light Texture Composite Sheetrock w/Light Texture Composite Sheetrock w/Light Texture Cornposite Sheebock w/Light Texture Asbestos TyP" NAD NAD NAD NAD NAD ollo U 0 0 0 0 JUI O2 O2 LZz?Op SUSPECT MATERIAL CONDTTION p.8 Type of Damage N/A N/A N/A N/A N/A Sample # ws-B-001 wg'B-002 w9B-003 w9B-004 ws8-005 KEY: Sur: Surfacing Type of Suspect Material Sur Sur Sur Sur Sur Overall Condition Good Good Good Good Good Damage oflo No No No No No 0 0 0 0 0 Jul O2 OZ L?:?Op w9B-001 w$B-002 wgB-003 w98-004 w98005 p.9 POTENTIAL FOR DISTURBANCE Sample #Accessibility Y/N Potential Contact High High High High High Influence Vibration Low low Low Low I-ow Potential Air Erosion I-ow Low ["ow Low Low Located in Plenum Y/N No No No No No Yes Yes Yes Yes Yes c.rJ\J<. it: <lJrn KRltl P.O. BOX tt5t2 vAll- coLoRADO 8te5s TO: K. H. Webb Architects A|TETTIOTI: Stacey Jor*er PRANaCT: KKr| I.;UNSULTRNTS I NC.9?O 949 15?" 6t19t2002 2:0O pm 2:40 pm Sunny/Vt/arrn p.2 DAfE: AERIIIE: DEPART: WEATHEN: JOB N'NnBE& touix ef Vail **0F --- GOPY St'rburst Drive Guest House PFfli€H, AT sITr"' Stacey Jonker. Tom pEterson SIATLF ff CetptEflAv: Not yet $arted I visited the siG refererrced above to ob*rve th! existing constructim and discuss the strueluftrt ramiticatiofts ofthe proposed rernodel. The &opped ceiling orer ru rtsairs fort anJ fiving ;. L to -U" rernol/ed and r'ieexisting loft floor beam, whicfi is cunendy dropped, is to be raiseo frrsh with G toft noor lcs,r"- Acconding to the- existiry stnrctlrnl drar,virps, the roof lraming is constnrtad as a corryentiorut gabl€ with ljdstrafterc supported m a glue'lam ridge beani and ttt" "r.teriri walls. This system does *l "pp"". to utirzo collartiesi theretorc, we believe that the flat ceiling may be removed without any stnrtural r€inforcemont of thsexisting membeG. The loft ioists 8re not sho/vn on the. existing structural drawings, but th€ baam supponing the iois6 is shown as a5 lr/8 x 12 glue-larn. lt is wrspped with rough ,",rrn ."tri"'i, so its slz€ could not be verified. W€ ,Bcomrnendrsmoving lh€ ttim on th€ inside_fac€ of the.glue-lam, ternporarly "upportir,g th. "itfng ioii-ioi"t", cut thern backto the lace of the beam. verifv the joist and Leam ize ani instail nei,v srmis;rlurtii;r ttiil I hangers" Vrily alt o(isting- conditions and contact us tot fecommgrdations if they are diflerent than those described abov€. lf you have !ry tsther questions, please do not hesltata to ca[. COPY 7O: FIELD NEPORT Tyler F. Aldrich to 6u (u o .2A c.t 9X XOr c*:5Fmo ':J ( o E o -o -o o = tl E E. E II '! a o BII tr Fz drl FoJ g TF de nAtb I IItt ot.9 p tu LN =o :EF6lulo LNvz T g'b D! 10u c'toit EE 9a dr E. lu,6IF; li: oEo D( .:t,tr Ebo F-8n;i ? ne E9b5 E I !o c e s 3aFE =, ,xl =l--{ alal =l &'lel =t =l -l r:-,: I fl<IullFl r-lUIutl 6'ld.lrl z Eo l,u|\o\( trj Zoo \JFoo9Z'7 LlYt ,i74zz= <o oa 93 HE e1e 3fi e=H3 ilE 7EU6H >le.l<t =lEIllttl FIUIurl 6t4lo-l ul ,';;== 3<=E:=llc gi3" HEgf; 3<= F gfiE3 f +3; *=; H si;$ =5H4 5;4 ? :t4l Ea=ga=g=ail*8S=\ i'si s 'sis5 q.:.!dl --:..! n! - -Cntoooo 6t ---- Xuloz uz =d.o -6tscIih s>F. Ergg i l[lgEg gE Elg ;EEg E[[!Ell:fi!!lt:gggilaE,l iE E FE ii Ell EE EEE E#zi'i Hl E EE EIE il *lE iE EEEE il;l il EIEI EttEl i ilEE li lgn lg :>bc> tfJCJ -Ll-lJ- (t) IIJFoz J d u.lzulu 3 E E o F|rla Lt4 IJJo- o o6u '6 o A c.t TI\ c -.:fFu] 0 N ? \ S. !c o E t! tu(,foIFtn IUl(9 (,vz tz I d,lu lJ-.\ lu =6J< [__. U)F=,^ X a1:- u- a1t- ->u)6* =Etntuf-u.riFl*-"; =3iH6; F jJ = !, ax uJ llJ E uJ tFt!z cl !, ExIU llJ 5lu (,zIo- uJ LlJn Q6..859 P:ApsE, u 1e'E o9; =-ioIrl UJ IIJ 6-d5FOlur d.H c0< (, F t =lll l.u =UJ (9h'z*>sgnz<=<o 2. dt o_ =lrrJ <t o- JccU<o- o F LUa t- E& IIJ ,. CL zvl 995l YEil eE EI E?kl Pr tn 11 8r(nl JrHI dP9l *g (.4) Xl 23;t 9fr6t qk =t -4 uJHl <: =l y?i II EfiEbt .<dZ.l Fr clt t! r f-----'\- o5LOC ."=9>ira E6RLlJXJ -.r..,.-J- t * o€rOC =ou=z>v;lJ F '.''l>r^xTUX=- (r lll r!-! - ct = =UJz o- IA 6{F-Zt4a=FTrltnE o*-{x . =;9>:r = =EHr,lJ x <duJo- tr?FJrn€x> IIJ F>uJoz =6lrJ <d(J o-o>,/^rF-tx - =x9>!r= =62r.J.J X <E lrJ o- F-2!4< ,rr 6 oe. d9dL _o -o o 3 .C, zI CLzo E -Jo IIJo J uJ tuJ d uJ =oJ lz (5 o o(J 'to qJ 'tr -o L C\l c': (/)0 ,{ ?(-\ o90b a+t o tIJ(,:) =Fatllf avz :E z :c6. uJ o ll- l.Ll a\ J< I I I -*->'- tn l,t) a1 <-z(,4a>F r.rJ thd I tasolf I -l li=J\ [ rr uliUr<YIJxt]t > tBo z. \!>uJz' HB>-1 r t:-i ___r# ill ill :{F-J\ -o -o o = 9: = lrJFFaa =;rlJ-'L-r!+ <Ya-> IIJ )Ztt oF UJ(t t-td LUo- (nzvt P9d.t ;.. = =l 5={l =uYl drofil =zXl Fr tnlt rxil lUq(nI JIHI iPolzl 'rE (Jo LD xl zsxl 6pe] =g3l ifitul <! :l ssEEI HH=2l ;Sfl I I,/l."' l- ( (nt!QTxlHl F(nx LU LU =uJE t>:<Iru, ,^<tr| >4Y| trF,,\ !!YkI\ ilFH| \ u7.=| \ <uJzi \T"t\ z4Jo-zo EJ LUo tU lrJ -Jz lz ooo -9o(J '= o 'c -o9X c -.: fF N \ NaI r-t &a o .c. (t t.t l r/)foTFr/)ul (, (/)vz I (Jotnvtz xl 23 f;e El 9E:l 6P FiE =l 0= 6l qH HE" xt =uFl d= =FH El E? ?I EEE ;H$ TI Hf;pl EE= *p$ pl ip9l ;$B *fE 9l ;f t--t e? 6zI uJItr(, (,' z. trur =lu-(JF = Y aFT =\zt^ i- a^ =tl.l uJU 5(L uJd. tt z J o-zo EJo TUo uJ tuJ & uJoo-f Ho =oft F< Efi BE5r ?=IA eE gE Hfl4d z:) F(tlx uJ lu o =iut tr'\ \ I o ?=!2txa1uJ- ulv gH u.J 4d. u- (nzI UJul t Fz UJ =F 6(n irtsxlou aar >uJop =-iUJ IJ.J EE llx ul cL| | url>r-oiFi;= I,/\___J__ - --rt---r--t !F - -\il -,!rrll!t ti t [:lli! !i\Ei'r----ii-t\f:====J I I I -rt-----rll r' Iil EIll bP Ii HE =d (J ar/) q -o -o o = -c L LIJ o6 ILo e.zx$:E =uJ1>JO o FIIJatEd. I.|.Jo-)Z o ao!- -9 Q :-j ao o .2A c.r IF -oxc -,:JFuto -\ a NR \ a \ TJJa oIF6 uJl(9 (.rlvz - \d L 6 UI\ -, rt -^ {l \l-t +!>5or ^l'(r (9z .? uJ lJ-a\ llJ z;J< I II I I I \- c,l ctI Jt \)r(r I o =trf ,z |- UJz 3 UJz l\ t Ht = \ I h'F \ I H!s+ \l !6- =tr a I idd.^. =\t EH EF EH E3 \F*\jil$ \DNVd dTJ .n tge/5 Lqia, -{ \; J $-vII €a L 8E -J_ (r- d6 (vl ...r <t s/) qq -$fr(i/-=w^. S* 9o t).El - LJ q.,r/MI 3F =kIu llJz- j3j t$et=!t- 5dJ @ z.,t oo)<l l- i-5l YE =l 6=xl =u;l 6strl dFxl 9r i,Tl 8x ull -J -t-HI iP9l ;1 El Jdl r- uJ et +4c(t ..&.ol :roFl sro;;I FJEl (JrL2l u4 o ,l uJr el E[ 9l ;S --_l I }Z(J ul ILo9 uJarz6J< I\____._ | o lqt l'.{I ot IttaIU(v)txt ttr] B) FJ luJ i4 35 ,d _o. -+1v:*<s-j d -{ U € -i r)7 e-'r IE3 >-- 4TJ #3 JJ $g $F *Gotr hVlE(t', vJ ==F $JE E+4fr u'. o- #IjEs o )zz tJ.) -o o i -c -\l ;t { Jt s5 s"I J --,1z<i=>.1d\JdZ }Uu.t ^z19 i' -_.r -rl inti r{ ;=Laa\z =u^.5 erE U)rn= :,:LFF9;xx- ujx -.1 -l uXi< 4: == iEiu ENa=*uc = a)E zaE zIL J IIJ LUJ d. uJ BoJ Eg oUj .o OJ 'trnN iiN E.! .N \ \t N a No\:f-\ \J LUtnfoIFtn LU =(J avz I oz. -& uJ o. IL i/"\ LU;:z6J< I I I=-.-\ o H;*3 =F>q =f3xr- :' z 'i' flE?E3i6> EH>P 1?f,^-- F 7,)br- -/i *tW d. IJJ ...o- zvl 995l YEBl *o< xl 3U Yf t t.\fil 9.> xl !.rl (n Tl fixol JrHI dP9l ;=' J Xl raa El ;q*fl 9;9FI r!=rl.zl )Fo el E**a(Jl .>FruZl Fr Yltn 6 LUQ<Fr *=7< =.?LLG U=<uJ\zH; cozf, (L>o5 =*z.o (',2 6 XuI I(J F F z o t LU olut LuzoF(n =lu zIo- J LU tJ.lJz = -o -o o = IZ o aol-I (J '(t' o /1 N-oex -oxc'-JF A\W * Na\v Nga uJtt oTF(,t') ul =(9 avz I JI e .$: / +T JJjtr T:? Li SE $=ffv? 2t_1 g tnz iv=,-Fv= AZ;8 \l2. |Jr Ln!xuJ rr.l dP .i: ..r trYl -a>ol <Jo =t +*Fel )l)et 6=6frl 9;9Ft u-=u-=l 2iprl - -F,l lfi:= Hl >ht9\rl .>Fl.rJzl ,4(,.'i1.fo o \a $J qY3 ,75 3 f- s (t =E >< IIJ IuF = F t--- =\zvl XlJ UJ =LUz I =qxuJ u,l. J'r- <Y trsOOXFlrUJ+>!? =;ulvz. rn z J CL J UJ tuJ t uJ CLof IJJ =_TZ(/r <U)i(,=l6 J5r-E: -. _$93 xgfr 3Jt; u.l co Eo; <F>ru =EuJ<z. L) lu m LL 6.2 z= JO o F LU(t) F =t IIJL -o -o o 3 JJ = -ef-\$EhTqH,$ q. | ? $ \)45 F J e dT g \5 " 3iz '(,'- = 5Udza==fr5 ;3 Ez b9 Ltl a\i H= l = I 3 z it 86OF (o(J NJ ,,0-,9 =:.< iFr 9ld .? 13 '-30 ztA -\z oE(o C.l E8o(\l(Jc; j("'l .or.o>o a * r\ s c\ R o lo o o vlof(9 o .2 o g _o t, r_l Faz+<zo;t "t=ffdFv<<L)Fr.|l<u)ICN G. tr o.tu F6-=(J tr- (= L):tlJ ul uJ->g[r<z> .F (9z tr LNx TU I(J F : F z o6 F2 (,ztrIXul -U k = s tl ulo u) d. d. uJFz di 3o oo r.fl 3 JJ =(o XN =lUz Lo E=J!n (tX uo uJxl{ >ft =cc9P tZ l- u- {, 3i,.' f {=dotlJ Z o rno ll J UJ LUJ oze{ tr uJ -Jotfn 9-*t PP E H e6l Y6 = I tril eE F 9g 6 EI E? ? 2F ;=Xl HLn H H. rQ:l ilil 3e =F =6pl ]p fr; "n3 gp 9l ;* rE ";P +* 3pc0,.- tr 9E*=Eiu3 x>ei g5F* 9-B =H= ZF?cu= F=qt Eoz9 " ====tnuJuUJtnUJ -d9ilFY 8i6r9HgifS?okiadFco<5 t-ait t8t Ifttz Ell I zo tr(J IUm (,z oJ5 d] -o -o o = Uz U IL o- F lt ttlafo-Fa I,JJ (, V. z. I o r r- ilT --l o f---E :: :=E : --E:Irnt-=-==-F: lf\/-rlll \/ll ll \t ll"v7U I III :1E:=F=: tf-t ll TL-J --l [- -\]\ -ll tl r I I L-J ,,t n /' ll/ll fry )r(rl l=T-;1 l'l. i ', /\ I >_J__1,/rffi-T-[rr\,r \ ll ol l.<m -T o oF LU(t) F =d. LUo- _P+ "Q?ZzP =2.rts3silp9H r;Iri lf #-Yi ii[-l oll I>dll I ;lEI z -Jo- J U t-U t.l.lJrtl J LU uJJ UJ =oJ lz fs E(J '(u o -o r]c\l R.c;u '"'lf,(orro N $ Ra -ol uu -oo o =e t6 lE 6(J '6 AJ .2 -o.i;o ca! =rc;?.!f(o(no \s' \ N a sa o uJ(n o-Fa UJ (9 a Szz I z n2R/_\ l- n \-/- z=- HEl 6giBFH P33 sel 3frs g *Ex= are= hf-- ILfp_____J tr----.l L______J . I ,,,;ry=___))=: _ _ _ ,r'"'tre riil rt lEl I iiiii I El ilri ( l-ri:rr_-lll\';ffi ll Y'l!-j Jll \'r_-rilll_ti-"p tr---- tl ll tl II ll tlrr l--ilil |3llrr | 3llil |8ll ', | 3ll li ll il tl il ll LL_____________ I rftl _l __r I -t--n l1 l1 - -tl )!_tc -D-T\ "-L',f-tltl ---- L__ __ F -.. ,"nll \/ io-* ll! I til ATf ill ill ATf til -o -o CJ = oF UJv) F Ed LUo- - rr----r r -f--lrt rrl iJ >< | (J-l'l {' )'l. \l(< t\ z So- J e,F(J TUJ r].l JtI| tuJz : IZ E(J j (o o Ant gX Ef!f (4,uto r{a N R c.| E. (! lz ]u loo I 3IJIPlrrJ I trI ril f(9 gt \zz E =t!t!o(/) l!n llJgo J< f I a I '-= | _______.1 -l --.:|/"./l(- -l\le r:t |lUt I |<tl tEll EU--r I \l - - -=! I ? T I tat// _r4_T\ ,\| -s l2,// L _l o FIIJat Ed IIJ(L --_.l o I z -Jo J 9tFL)ulJ I'J J UJ uJJ t UJ CL CLf -o -o o 3 g U |o o /'\ N px €if l.o(no o o =u-o lt tuafo-Fatu (9 (/lvz I oz uJ 5 J (J &F(J LIJJut -o -o J f;*. ? 3H H=:H=*XEE E ?F>16 q += !E;:*=f; l;g IH iIg (n UJx z J z .L! =q= gg +< .^26fi y<+ y ct =5- =P El6 EI t=D iiu:l fl zYn c Hl iFrH= i, EI fr s UJ*U I Hl I 5 i5etr d =I E F t;-f;F E-,fil * 0 *;frt ;9El il = iE.,'+ >( *I E fr E=ilg EH F{ l\ rY) {+ # {+*V€ \ZU F{zuJuJ7 z(!ul?r.u trUFU uJz JIP6 =iLN zF l-FLnU X:IU t! utJoA UJ;i th m ri. rrr'(J(JUTFF3==vl ul Ln &.lUFo-f,t.&, IUFz F. -Jf, Ir- ozD &.(9 E(9q LIJ Ug LIJ(J uJ IUXJ IU IIJ?ddFfftoEuo_l!TIJ IU IJ&, &. llJx=ul |,.\-'t ;- Y6fid IU t--X LL FI =uJ d tlJ(, FtJ x?oBzqo --Jl! UJ f( lt-Xur.l- d.Pl oPz.7 H E 6Yzll iilFr.rl (Jru=o o O2Aft/]- 6fSYOtro3?n:sHj1{lxur HE,''JCLcr. t)Jo t J (J F(J UJ Ltl 0raqO@oo F.uJa F Ed.t!n- \ UJz =-r. Ur 3 3uJz a d-\. ur\.(9|t4 E\fr $ € CIatt 6Ii-ex E 'l E og ; €i m t- (o t-t L- -_-l lJl(/))(J :ft-(n Lr_l)(rl (n iz z. :f .1 1:i ...i el,l S E ;i ,i.: oi = e; ''1 1= *'*"eaa6 ai.g 9ltrtr!ftrLE !! : :i ii. 92 (/) -j-od a:. O =di. a) F9lx.-r-dp :!q =rj ii5 - F E.td i! 5--l ci = Kt ii= s,-F E aj f .E == *:e q r.E -.o = :jE-*FsF€ ; E=l=t; 11 ,? *9ixij-S-.-r€riE iui€l{r :? ''i .-=;:};;=ggeRP@E: CJr--r3*;:S q:laSj:j t]r:rt'ii€Eg F$*F5HF FFF55E 3I J" J,$ >€ _(:e, di\ s\41i')6F aL \fltP ] ..1 .(luJlL-I;lr-lUIUJI dld:l u..I F.' o\ rfoo (]z dJ 5 ao E O Lt:zf, ,-J<*|.JYlnv{Yt;t-,--'-UII/\.u! :i Iid '1 ,i s>:ur.u -; ,z*'tj< 6: r:z '- iri.t:i --ltJ t- L) -JLtl _l u.l ru LJI o " z-.4'z Z R "-<_1 :sl do- ul--r .,i AjjY; o* tt! -i 7 *zN*, Ief5 ;i =-r i- i.i )-tu-ii-z;d<l e A=ry*;^o$^r;E 65096 qftx l- iii u;->Jin4iy;1nzu1 l*v;ff;efg!\\i xlu-l Inl -tlz-l*l (.l lzlil<le.loi \ 14t) -L\\'\,1 Hl r t ,vl '/^ '-; =l Jc"*i * (9 El u 'i, )i' \=*rJj t-l h:l I B I )t();>3- -*Afi\n I :h[ *"1* (' -(*L nl .LJ- l,4) fl,.* -.:: (t\--l__ ., C.(-L \C /'r *1- vJ t-n v) nl '!-:. ,^-v ,-V-\\-/ *>-.-- -,. .' l'_t"l* t't - E n J) c) i: c :f,uoo zo trUf,d. z rl o- U oz It- zr!lIo-o -lLlt tuo lttt: J a(U JJ :r: { a) t' (tt-zoll uJz!u -j9</aaz hQco F--, -(:>v<F\J.(x FTU U ll:yi5 JK<2t-.(L-' -J --obHi nl- :d-tio uju.l l;L ki:? ai9aiinO <i.r< {r\tUl-; i' ao a_ uJ l-<t!?-zSO ott!z F= i'; o!;zZ rr] rrr;\dI!j urF rlni d T ll.l,L+r- ,o3= GEiho 7.7\ttz :: =(JUJ -i Lrf ro Ol:.i 1.1 u1t-c1F ?[ilo tr - i^ LU 2IXF ; =rr<a- rJ- l- nio3 ;i?{ 6S:Y,-i trt <d ul<*r H dpil { Ui<<:-r(9", EFlIIz<(uo>z Du<< x, (J.O \-,<X{ iii.< "" rJ .ts/xt f; v^ =Ji: r^ " f'\L,, F u- x Hru r!.L - rtt -rF:< i:_ :l U-lP*t o. 6 fi 2 r r$ ? $+ F '''ififiirggri*$iiifififi i inE{;i Ig sfig n$ n*'51;IfiH='*fi-igii gg;lrisgggil$flr E iF E9 fr gs gg gr g i g gr ggg g;r gg g gg r ig *' fF F# i r sF :$ rr$# gif fd f ff if gf JtC tril N E Rr* R ,Zo rir i:({.{ [ "'r l\r i( tr-r U5n. z tJ t_ 7u-ON Itl IJ U Id. :Tftt) t-U LU *\/ IJJa)Ort-tn llJ)(9 y1 V az :f ct q)a') CJ i, {') ;9-a' ii:! < + =J(| ^r1_{') i+iit -qv <.:!i g"l-{ u,F<( =3 u.lz i-l .;t rl\*.iY L)(] 7-:-otir ^; +{ 3= .L t) 38 5or v'l o(- o) J >zrrll? a Ll, .al- Z ttt ;<<oIIJ L) F FIUtr>tL a) u)< ;ri o-i p>kF < ,-r H'Iomti:f/') rxFSe5\- jY!?c.!.-l > LU :: )< l:L t- cr L,.) UJ F cra.OJ/\ .>>-. tu zo E,,F -.t-_/.{ c) 3 LLJ ,,1-r-, sT o/;l.o \r'|zF =r:14 -i ut (t) ;U;im ;;lu;z6: 2.;l Qo::t i- -_Al vf;t i\?5i i8rl ayl-l (( F-Xl ltr Lo'1',| !: nil rri ul |nl ,-r :t:i t -,|Il-.l .( Eolzl ,-i > .4*gr xl g r $; E: 1,,=,,;glf"9i'Z ilE rr:l r:<g j i:=5l ==?-<r 2;, Pi-l JLrJn+U tc( <iffl "'=x6! ls di.5l r.Ebkt JEx tilell 5:-35P 3+i_ ilgr:l,l "*,pytr9 d r ur ':4 ul es3=F YHe i*;zl .io^il 6 "iHff _il (:) 2 tY. UJ o o!J = o'lJ<t '--*l {- o o TU om LJlt,tl a_\ I.U =I I-\. I--\ |-t.\l --=--l L ( _i 3 3 UJz :o o: r:F q- Q !',qa \J _: ..- g ElJ3 v 3g F Lt\t a H T] +3CT LX\)5:*u {H{-JG ..Fs'\9 c4\x $€ z z <{Eo a\:o u-- =ulz !! J C'2r-o -lz <:!]B'4 :, tll ul ^- rZ tr # Fi3*rflz a): llJ o:o UI :r: <: 3 otti t: ttl Na 5 u.lz il J. g 3 u..l >l 1-l i-tit ",. I: fi-;oi:oo cl r-.F (/l F.5 u_ rr; :) o- I r.l zoi: Ua (. z 5rL UI u-lJ(. tr-l =J J&trl c tr- c( $r 3 3g; firn \i-q ug o -t')\t -=+ j ;of 4:f uts4Eq.l 3$5f- IF 3T1 -J[-itE Llll*lli-3 lli-wl\ r-- F|-- 3'$:;aq il se:1e 3gjri Sa qe tril o IOjE t4t lo Ir-i ( I{! l-ol3: l^ -- JC\ JN do a\ioor! oiqr\o UJ :)o-1- t-.-(n UJ _-l() lnvz<( l: ^rl 5-lk*.XdI <rs5s-\ e\5-s< 2 o =5 =8xFoB{;oEiio ^I-r)i: =; ct (-J t- UJz ao =uJ itp <xfroc( u-to a5 tll .r.dI (Y, a) <{ rlJ(J i. trJ gc T -$r\t cl _ct (J I o --t0 fos -Js _e lt_ :,t-:I: !: lrJ :t: .'l Oz[: u)X ttJ l:(Jt: ol- :t!lF Uz o :r 3 t rJ€(r, --r'\:rV ?1 u0 olr-l aLl ^l OI,J'l i=<!? .:x r|.ltu .l z(fo .,I 2;Z :!z IT F- lrf; JI--l(l<L l_ .-; j vi ol =l sl I.IJ J ai 1t;l trtl i!iol OzBsr$r 5? EfrEE.,'fr? Ei r;jl;'5=uQi, E: a'_ig;'!PtE :{ IE-!rtfiiBHs fit* fiddalf;;F; 3*n tr:e*lHgF;ff "*Ea i**;l-romra ";8ff _UpIl d:o3(. arult-l -lrl fltlFIolzl s ! L".;\ l|Jzl)c)oo34tol- .7< -_l t-rl U:f u.t-z Ftn a:lz 3utz I .-t-. lfilt tLtil--t- rJQ >d- lY t.t.ll- c! 2:ll I'O U ug lud T; .{"-t * i+,:,{z----L'-\ /N I t 1S oJ--) '\, ri z<f_l o_ Jtu tLt .J 2l -l<l:l \4 p oJ r!oocl (o N a c, NOo cJ oi NoO ry Olo t-- C) lo Ir.t=t:lo(J 'au Q.' 'co l -c)c:t(n UJ(n:) f: l--r/) UJ:) L? ? z <( l-- l..t r1 (J 3 ll.. I L<1 =J. _g c4 l1 .l.AV€# ,{di, c1L5<K r-*ril G-o f, $fi fi# r- L-_ o IYoo LI -.iJ :>I(Il fu (n IU(J ;lulz C)O(,c{zu-'{ qf ii4>JO trfi=rdd! p() l; r- \=! 7-di: lu tn FRui ul -t :[Jtl< i:- .<{rr> 9 = .'.)vl q.'ia *9 r: sl F:a3 E+ [t sl =i;-1u 7fr ?3 Fl +?Hil5 i*.. 6s zl Y1 Fo<- ur o iii l"t Url 3=3:P 3*! \vtnl *99tr!, o.-ur ,ztl uH3=H Pfia i*zt -; o*Fd ";ElI ;li vdo d:Iri t-. LTJ 8i =t:1r = =ul _,r+- g { ,.$P-fj r--..-- i € { F J.ST Lr)il () c) 2a >' L'rr- IJJz m U a(o O {.] Bttl 7- UJ u- (to= l+i (fl)z()< UJJ LLiJii rrs> I-L > x!!t.u t't llt \J d. > -zzts:r :nru <( _t ;Z.i: ;; -vY<,I-T "ii(+: 3<.J-FJUC . c, tul;li I tnl el$ol iipt 'rl(Ul c0l \n c)z .<(f-t:t r!lz: 2= a-I fl.) tU2: "{e-, z cxi Cl C](-) 3 L!t :z.:( :> I F u.lz r- in!3go ut :t:Zrn -t) I :.1-i ri\t)\,i a-)ii-}zlr Eoorr< !- a! 4. rtur iii ifl=UOru :l:za U) tLtr] 2a(. o l-:)o {): ::) )q/ -'4 I\> -q3l{\)t-z_G z4 J n- J TU tLlJ t"ulo- :f _l I \ I,.1olQo IE.Z Iru<{'-r :t lrj 5giJO< o uJtnf,(f It-rn LU)(') \n Sz z..(:r vl .,i a) a_] v aXl Fi h c o =l 11 = + + l-Yi + -u {- :\ t')>l o^ o ; >) *l >\J lF \J,,\ =5l :cr ,l =Y o4 oY X 9i: '1oi:i i= fr 3!l :J=Xi ltr i, lu ,,i ii; < l:'.rl Q i lj Lj; t; sll id rir Fr (r o; - 1x,^l -,:r H* Jir Arrlill rg Efi r;: :llpYI +/\zt ,J >- c.r ill _i i: .r E :<r u)iri !.lla^' t:oo l,l Z ^ llr.-i: J |u -J i ^ r.l- v) "( XTO:J LLJ * i: :{ ._L J n: l-t! l! t.L- Lrl (,z J t]U UJ (Y i:z u-l E 3c] o3 (J o(n rn 'F >< :f JJ UJ o: TU : o;d<ut()r-(9Zta-bT '' (, (.J) d: ,-tu --i 5 93it- 2- J. aI d;*tuOU3=b r,r 9.;>-=9<Fr_[]FrrcrOcc<@ i-t i l1ll "-till \2f,, c) tl o. -c c c 0.) : -c i I i Iulbzlrr)lr- :l?9t; 615 *F o1 ra) II *luJ u.lJ f). t- ci F;y) )< LU f: L) l-. >: ol* (9z;i(J 6 t-2 CL llto tn (Yo c( tlj f*z ni (J &r 1n =-l =(o XN uJz -li ;"4 -..t F -- z <o14 l-3mu.tr;,o!oClda E =.-, t= ulq i7i cooX =\-L,',z u-l ul a (-) K\ ll \J "5q) --( $# fi$ Ef; (o .1. Fl F-t tlt LLI trl .J l.l_, UJ -Jric(ol -Y oli2l-t &HTrtrovED t Ccrcr,'. - rilT D :velopment DePartmllI Buildins SatetY &'t3::,il:: TOI'N OF VAILIY $ction 106.4.3, uaiform Bulldlr8 Coth WdD y"::*: Hilifrn-ui#;;qffiro*'fii"ffiln: ii ::,:i, 1 ffi ;l'ff ;[ frr}g*g;f;"T**H,-"?ffi . f , ,,. ' r. 3 r* e _authoritl.E-.rw-.n ra hc valid. ;:i. .: " ;' t::l#*mffi-ffi"i:l**"g $it',;#H*=H€"W## P, 02sbP-06-200tFR FA)( N0. 970 4?7 2965 T { z (\ +\r 6'qt$ =, tss-=Fg *E $- g=$ 3,LfsFST)r6-)1l* vrt/rGTz rfiF= ,iEFF 4m=J *E.d*lin g 6-'4 g €q 00 v !!otn si {=rdIg 4A Hd 1T' I ) :l 0_s R o v =ll s Io|= ?= f\ -- tt .y' ,'\/ --:-Tl -# I F-l O \9rr\?: --/:-\0r\ =.r \J * FgrnOtanJ;e E= H--I€o-d 3Hv|o &o o9ccl>Zt- ffsJ1 u-FogEd riF6tEE&,o ,5 'o'u "o- o & (l) i{ 7:'\=::1:1"?4r' t... Fn ',1 o q987. | ]b nr6 '0N Xg.l o slnq.l.lH3ilu Ffllll'l 'H'I tJd nq:tn lN{ znnz-qn-,{;ls N Q \Sc) s- \) o .e A \J'2 -= $ o Sl.0iLl.ll{0}lU flH:ll'l 'H 1 UJ nq:bn II,l 7nnz-qn-J?c 9 :s rl+l sl dl TI L] FI t6e ==fE HeE alEI=EEEigerEE 9982 LLt 016 '0N XUJt0 'd als E hlE ! dl stpl5 s =IE E-lt u I I I I I I I I I I I I I I I I I l= l: .ll .o- o =l'r! .c z. \ (^ s. \) '{ d q Jlll u,J ozN -d \: $9 gt ul lul s,; {':bP'h e-jwg .95 +:"jA T 3J Ar oo t{ tl J 3 t!o o.oF zo <l uJJul -Ffoul ulutfoIz IIJuid. c, o6tEO!gO6 f,l 6r:(J.: -ol Sp\>oP.2-6g ERis,ie -6{ oDh,ro=j ig YO Eq 6e1tu )<G,JO llJ LL E UJ F 'Es i9! f;g Ei ?E cs Kz hfr a= ?E.n< 5u J d. oPUlLll.LNff,-1 -a-,f e. -.1; I eo t3rE> d. =71 Rizo;A 3 qP ==H'zd a 9; YlsJ6 rn aD< cq<F ,d (l _7 -l<IJq rS:F, \+ =od JJ 3 Eo (\I Fl (9z Jtr|J UJ(9o UJ IE3 gtzo6 =ulto \ZI(JUl<l4J-_tt.!, tui;o a.P (9|o FiInLx5 luJ o 3 9 fid60>Ful 91 H+<F 5H =UJztoILxoo uruz IUJ t!Dz z d uJ A- ulo =tF J ocfFUfGFm o uJ Noo <= Fiz =sP=.o< =ulFth ul F E6N= au!l ut<= HZ1>.Hfro< u-f,z _= =d,-l lu <o-oot.lr zN= ^- ulEI aD lr ooo3 |9z F[nx UJ3 d,llJ ao =ul =f-r!r!Iln &.tllJ z(, 4 l--(n =u,r 0tn uJuulz UT 'r (9 -'t z<rz =();9a!6 (9uJ2AE>gloxtuJr E -Y- !ro!oo5c!Ei.ol 9p;E.>=6S ERE9 .i8 UJFu.l 5-tzd 9i zE=3 EF F E; =aF |9zFr,lxlt, IIJ k oFFz, o- JJ UI ouis3oF- ?=ds "t)?2E=gs(J-)Et EJFIIJco<I^o- (9z d.d.f(jl r.L-\=&.F IIJrnJ =<tuZ FIc, J \zul o U=;-i uJ<zco |rJhk 9.8(9=zo E8ur< Iul &ul ooz llJ kuJ t!)z =&uto- (9 =-t,,'| -,1l! =3 o u,tNzo&.6 o tEl I lEl z tEt hxu, ourFoz ul UIo-oJvl JJ(^ ooo3 SEN=->=\z!z ut<= frz a=o< J= uJo JJ th oi uJmfo hutfo glvz I o ft, v) \l O ,,%;-F 2i#! s"i =a{rt .\._.,&o-s: !d>_o SJ az.5 N!\i Lg d,ooJu-ou- ulOIru9zz J IJ- J PoFo-Fi, H'= r6f5 E?5r Fz q H;gEfrQHIggdp.Y=g H6-> EEH E5 J UJ ulJ E uJ3oJ zo G,f,Ilt-zoU =ooz =tatulut 6,(9ul 3- .;. -v J 3E fz3 *,duj - f;E -Aa=lg*;FIEEEEr l \J -!->*-S e:q=r!(Jo5 . !z .-u (J --l 53s+ = E: F; r6s4F' +9SE J ir';a xEF= =fiiEH33= sH=*r 5E* IIt iqF! sHF*r 3 ?i 7zfrdEl s $E \o'l 9Ee Ihfi= | EJEg Fg=ExE<xUJFO-UJ h 3l EIdPJX<urFl!< == t ]Udl =ut =Flu IIJI|n oFx|Il (9z Fvlx uJ d.L E, uJF = u-fz =t uJA. frs 3F ud vlr-i?) 3Brhd UI =ooz = Por4zl- F9.- uJu-I =P== =ood. =H_.1 J <r! gR oF (9 =Iul 5lJ- J Ful = t! z =d. UJA frz 3R.a9 l-- + =>*slf,d. |9tz HF EEt.dtu!x+a6ts o;zU<-u(,n =zEhEs EJPE-tg=2xd.<uJFo- ,rT JTdWNOFVATL 75 b.FRONTAGEROAD vArL, co 81657 )70-479-2138 Job Address: 2039 SUNBURST DR VAIL Location'..'.: 2039 SUNBURST DR ParcelNo'..: 210110201009 ProjectNo: CWNER PIERCE' MARITTA PO BOX 1123 VAfIJ CO 81558 License: CONTRACTOR NEDBO CONSTRUCTION P.O. BOX 3419 VAII-,, CO 81558 License:25L-A APPITICANf NEDBO CONSTRUCTION P.O. BOX 3419 VAII-,, CO 81658 License: Descrintion:;ffiiffoR REMoDEL: MAsTER BEDRooM/BATH l'owER IEVERIT BATHS,DRYWAI,IJ PAINI,CARPET NEW BOII,ER Occupancy: R3 Single Family Residence TypeConstruction: VN TypeVNon-Rated NOTE:TI{ISPERMITMUSTBEPOSTEDONJOBSITEATALLTIMES Permit #: P02-0211 _-''-''.-.-l O orro**ENroF ..MMLINITY ot-,t""t ADD/ALT SFR BUILD PERMIT Status...: ISSUED Applied. . : 0710512002 Issued...: 08106/2002 Expires. ..: O2/AU2003 o'7 / os / 2oo2 Phone : o7/05/2oo2 Phone: 07 /o5/2oo2 Phone: 970-845-1001 Fir€Dlac€ lnformation: Rcstricted: Y # ofcas Appliarccs: 0 # ofcas Loes: O 4 of Wood Pcllet 0 ***i+*,t+****l*l*+***'+*+++j}+'tt*'+3',}++**+*+*:t't.+***+*******"*,il**4FEEsUMMARY+*tt.+1!***t,*t''+:t+**t*+1+**1*+*'* Building-> 91,240-oo Restuarant Plan Rcview-> So'oo Tolal Calculared FeeF> S2'049'00 Plan Check--> 9S05. O0 DRB Fe€'-.....---> SO ' OO Additional Fe€s-> S0 ' 00 Investigation-> $0 ' 0O Recnslior Fee---> 9O ' O0 Total Pcrmit F€€-> 52 ' 049 ' 0o Will Call > $3 ' 00 Clctn-up Depo6it--> S0 ' 0o Paymcnts--> 52 ' 049 ' o0 TOTAL FEES_.---> $2, 049 . 00 BAI"$[CE DUE---> S0 ' 00 *+t:rii,r*tla*talt* Aoprovals:iEEm' OSrOo BUILDING DEPARTMENT \'I-'/,/t7 / Valuation: $225,000.00 Add Sq Ft 0 08/02/2002 ACD Action:. AP Item: O54OO PLANNTNG DEPARI'!4EMI Item: 05500 FIRE DEPARTMEMr Itern: 05500 PITBLTIC woRKS tt+*t*ltt*t*t+tt'i See page 2 of this Document for any conditions that may apply to this permit' Design Review Board ACTION FORM Departnent of Community De\rdopment 75 Souh Frontage Road, Vail, Colorado 81657 tef : 9D.479.239 fa<: 97O.479.2452 web: www.ci,vail.co.us I0niN Project Name: Winterstorm, LLC, Changes to Approved Project Description: Participants: OWNER PIERCE MARITTA Project Address: 2039 SUNBURST DR VAIL 2039 SUNBURST DR INTERIOR REMODEL: MASTER BEDROOM/BATH LOWER LEVEL BATHS,DRYWALL PAINT,CARPET NEW BOILER & Changes to apprwed Plans: additbn of window at upper level of N. daration, redue endosed light-well on W. elevation to egress windou well, renuve DRB ilumber: DR8020322 LocaUon: @1Lil2O02 Phone: PO BOX 1123 VAIL CO 81658 License: APPUCANT NEDBOCONSTRUfioN 09/1712002 Phone:970-845-1001 P.O. BOX 3419 VAIL, CO 81558 Ucense: CONTMC|ORNEDBOCONSTRUCTION 091t712002 Phone: P,O. BOX 3419 VAIL CO 81658 License:251-A Legal Description! Loe 16.8 Blo<Jc Subdivision: VAIL VAIEY 3RD FIUNG Parcel l{umber: 210110201009 Comments: Motion By:. Second Byi Votea Conditions: BOARD/STAFF ACTION Action: SIAFFAPR : . DateofApprovalz 09PaPO02 Cond:8 (P|-AN): No changes to these plans may be rnade without the written consent of Town of Vail sbff and/or the appropriate revie$, commitree(s). Cond:0 (Pl3N): DRB approval doeg not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. o DEPARrMENt oo .o** .r-h'ELoPMENr t J.".41'- ! k"r-^ Building---> Plan Check--> lnvesligation-> Will Call---> $295.00 R€stuarant Plan Review--> $191- 75 DRB Fe€----------> $0. oo Recreation Fee-----> $3.00 Clean-upDeposit------> TOTAL FEES-----------> Lo/22/2oo2 Phone: L0/22/2002 Phone: 970-845-1001 # ofcas Logs: 0 # of wood Pellet: 0 $0. oo Total Calculated Fa€s-> $0.00 AdditionslFees-----'> S0. 00 Total Permit Fee----> $0.00 Palm€nts--------> $489.7s BATANCEDUE-------> * +a+ t +,t rl * '*:* **:|* l Approvals:Item: 05100 BUILDING DEPARTMEN| 1-0/3O/2002 Jnv Action: AP Item: 05400 PLANNING DEPARTI{EIiIII to/24/2oo2 Mc Action: AP Item: 05600 FIRE DEPARTMENT Item: 05500 PIrBI-,IC WORKS o TOWN OF VAIL 75 S.FRONTAGEROAD VAIL. CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALTSFRBUILDPERMIT Permit #: 802-0355 Job Address: 2039 SLINBURST DR VAIL Location.....: 2039 SUNBURST DR ParcelNo...: 210110201009 projectNo :,()@rOZ .OLL; o$tNER PIERCE, MARTTTA LO/22/20O2 phone: PO BOX 1123 VAIIJ CO 81558 License: EONTR,ACTOR NEDBO CONSTRUCTION P.O. BOX 3419 VAIIT, CO 816s8 License: 251--A APPIJICA}i T NEDBO CONSTRUCTION P.O. BOX 3419 VAfL, CO 81558 License: Description: IM|ERIOR REMODEL,: REPLACE DECK RAILING ADD STAIRCASE Occupancy: R3 Single Family Residence TypeConshuction: VN TypeVNon-Rated Valuation: $25,000.00 Add Sq Ft: 0 FireDlace lnformation: Restricted: Y # ofGas Applianc€s: 0rr.'r'r.**.1:rr*.*+.rr*.r+ FEE SUMMAIIY r.rr.i:r at*attta+'t:l'lr*a *tt'l StAfuS...: ISSUED Applied. . : 10/22/2002 Issued...: ll/0712002 Expires. ..: 05/06D003 $4S9 - 75 s0.00 s489. ?5 9489. ?5 $0.00 See page 2 of this Document for any conditions that may apply to this permit. oo DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot ptan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and suMivision codes, design review approved, Uniform Building Code and other ordinances ofthe Town applicable thereto. REQUESTS FOR INSPECTION SI{ALL BE MADE TWENTY-FOUR HOURS IN OF OWNEROR T 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. FOR HIMSELF AND OWNER oo PAGE 2 *******,**{t***{.,}*,lr*****+,**:t*{.******i**:t*+***********.***,}*'t **********.s*:**,trt***********r****'t**:t ,}r***!t******* CONDITIONS OF APPROVAL Permit #: 802-0355 as of I l-07-2002 Status: ISSUED {.* 'l ******{*'t** * ********* ****:f !t**'i * *'i ** * * * * * *:} * * *:} * {' *,}'*'i******+* ** * *i.*{.* t**** *!* *****,},1.,*{.,i* '* *'1.'}{r**!i'}'l** * ** Permit Tlpe: ADD/ALT SFR BUILD PERMIT Applied: 10122/2002 Applicant NEDBO CONSTRUCTION Issued: ll/07/2002 970-845-1001 To Expire: 05/06D003 Job Address: 2039 SLJNBURST DR VAIL Location: 2039 STJNBURST DR ParcelNo: 210110201009 Description: INTERIOR REMODEL: REPLACE DECK RAILING ADD STAIRCASE *******:*** ***'*'*'* ****{rrr*{.******'*'}'}**r***:**!***,t**'}:t*:} COnditiOnS ********{.,}**'t*:f *******,}***'1.*:t'************:t** Cond: 12 @LDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE, Cond: 16 (BLDG.): SMOKE DETECTORS ARE REQUIRED IN ALL BEDROOMS AND EVERY STORY AS PER SEC.3IO.9.I OF ftM 1997 UBC. oo oo * * + i * * + *'t * ** * * * * * * * ** * * * '|t+ +:i * *t * * ** f* t *,s ** f* * '| *+ * * * tf** 't:t.; +{' r*** {. * * ** t * * *+ * * t *+ * * * ** ** ** *+ * * TOWN OF VAIL, COLORADO Statement ** *:1.++* * ******** * * * * * * * * * * * * * * * * * * * * * * + * {. {. * * **+* **'i** {r** **.1.* * *+ * * + + * * * * * * *,t * * * * * * *** ** ***lt** St,atement Number: R000003394 Anount: $489.75 LL/07/2oo2t1 :08 AI'! Palment Method 3 Check Init: LC NogaEj.on: #23156/Nedbo Permit, No: BO2-0355 Type: ADD/AIT SFR BUrLD PERMIT Parcel No: 2101102 010 0 9 Site Addregs: 2039 St NBtIRST DR VAIL Location: 2039 SUNBURST DR TotsaI Fees: 5489.75 This PaymenE.: $4s9.75 Total ALL PmEs: $489.?5 BaLance: $0.00 * *********|**:tr***********+******+**********f,**+ti'**t**4,!**i*t ,t l,+{,**+****+***+*{|******'}*+{t*:t ACCOUNT ITEM LIST: Account Code Descrlption Cunrent Pmts BP OO1OOOO31111OO BUILDING PERMIT FEES 295.00 PF OO1OOOO31123OO PLAN CHECK FEES 191.75 I,.IC OO1OOOO31128OO WILL CALL INSPECTION FEE 3.OO ll TVWNOFVATL 75 S. Frontage Rd. Vail, Colorado 81657 BUILDIN red for -OR IN l, etc,! /Uzas" C 74<*q-rttJ Email address: COMPLETE VALUATIONS FOR BUILDING PERMIT Labor & Materials BUILDING:$ 2(ooo ELECTRICAL:$OTHER:$ PLUMBING: $MECHANICAL: $rorAL:$ ?jl q!|i For Parcel # Contact Easle County Assessors Office at 97Q42!'8919-gtvi9!! ?tOt/azb rc)o1 Job Name:S'.4/d (,..J S-r orltl JobAddress: 209 Ect'ot&*tS /1<) LegarDescription ll r-ot: /S fl erocr: ll riring, ?pa llsubdivisior.: t/4/c ullLLerwPhone: Arch itecupesi;r " [io* S Addresg: ?fj 5.Fan v-,4zr.ItAtt ad ?./e <-\ K4 U 6/o Pnonttr?7-zfio Engineer: ru/4 Address:Phone: trrlt?-r- t 4-2 D.4./Cc4trL WorkClass: New( ) Addition( ) Remodel (\ Repair( ) Demo( ) Other( ) Work Type: Interior ( ) Exterior I Both ( )Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: single-family (1) Two-family ( ) Multi-family ( ) commercial ( ) Restaurant ( ) other ( )/\ No. of Existing Dwelling Units in this building: I No. of Accommodation Units in this building: No/Tvpe of Fireplaces Existing: Gas Appliances ( ) Gas Logs ( () Wood/Pellet ( ) Wood Burning ( ) NoiTvpe of Fireplaces Proposed: C". nppt, Does a Fire Atarm Exist: Yes ft No (st l NoK *******f,**s.**r.t**tl*******t**********FOR OFFICE USE O N LY****t************************$**** \\VaiI\datA\CdCV\FORMS\PERMITS\BLDGPERM.DOC RECD OcT 18 2002x(;" o7t26r2oo2 r rUOS" Parcel Detail Page I of4 Eagle County Assessor/Treasurer Parcel Detail Information Assessor/Treasurer Prope4v Search I Assessor Subset Ogett I Asse,s.lor ,SalEs Search B"asic,Bu-ilding-eharaclp-ris"tisslTrrx.,In-fp""rsralip,n Salsr-D*sjad I Value D,etad I Ltesl0entiallCommerd l Land Det: a\a Account Number Parcel Number 2r0r10201002R008139 Owner Name and Address IqNOWSTORM T T C lClO TURCAN CONNELL WS ATTN: RF SALTIRE CT 20 CASTLE TERRACE. EDINBURGH Legal Description Location http://www.eagle-county.com,/Goodtums/assessor/Parcel.asp?AccountNumber:R008 13 9 7 l19/2002 SUB:VAIL VALLEY 3RD FILINGBLK:- OT:15 BK-0326PG-01'17 I -20-81 R65961 I WD 05-29-98 Phvsical Address:STJNBURST LN VAIL AIL VALLEY 3RD FILING o6tEto(Uo!- c{ ia (l': (u.: ttl a IJJ(Jz uJo m |.JJt \Zz I €- ==Lio o -j..; j- = :F -N EE9 e= =odEf =.. =- =- --===- *X:- =>-99r-sFE-ii€= ====s=<=:== =- 6-:=;-o6=iF:+-8(; =v"!-=--s =;;; XE 9=cIa- =;-h>y= -e--xX= =F3=-='E€ -E€==;5 eilt-<l-= (Jl JlF*l sl ul -l<t Ltl a_lsnl3t. IFft 'ltJ- ileHl ;l E6<l u s ail Zaz{.6l a_ 99 ghl E6Qa;*l ,gh qF zE Hl g'E !- 6* zV EEEIEligggEgEEEEEgE l gll* !l l;;gl ll E *llg l lE E - E iE Ei E E i EE EiE I E ElE E lEE E gl ll iEE El g: giE gll E $E i, lgl aE *uE ui Fs E;sEl icl iE;!' ig! E* !! ;tl ii sEr 'E-Es Ei; 5i g[5; gri*.si=i g- li: I- 2?zllix Effiii ffr;Eil i; rif;ili r:: ii F EI z t{ ?: z (, a o o o i z (,zz F E Floz viz Eoz OU1";>z oz =E F< ^A_.] cOa r!F z J d UJz UJ O I _o- - -E. oc{ :(\ =F{,Y r-{ =F{(I' OJ 'co = =tn Lll LJz LUo6 UJ )lz T d a\zhq aVZo;z I-tf =3,n uiu.r 8=6Z 3R d9H= ?* frHot ,,-# (9ozd of zj!:- LlJ | :- 1-Er Ur 6618 fl= 19 ! ryPx 09 R i,,,fi 31 g=: 12V H6 >== lEA HE QVT Y;; f;F3 EiaE trUgh =Y-8:Pts liE= +s5 Ssgr * Sf;= tP= xe=2 2 =ae;5u;;cEi I I II lutnf T u-o Eo dulFz 3 v(J ]lJo €) zPu.rFfizgzox, FuJEi- YUJF 6ks <:ts]7a uJ ca l+5<>ths z tr U JaIF ui uJ t- zul cL (,/,) Iu (Jz tn uJ tU d. t t-u! to d. I.JJFx Lu =tuz iz Jo- oooo ON .oo!c! ; '-r -_r.lo o IJ f )(n LlJ(Jz[!oa Lr-l d. \Zz - -o -o o = ? = Z ;@,8 EE E =^,2_; z-. ; eAE rf ,FP: EA fig; it EsE;lt-z E EFA ="62 2zan- uzJ = zI kU II ui tUt t- z TU (n [tJ(9z6 tU =ult dFol;z:5ulL!tnzc =6\J t=l! ul 's3H 5ZOE F,=ru1 ot zEI i- tlJLU- F^oi 9En= b8 o LUF llJI,z) syir* Ei7F;|.r|.1 llJ:.2. =Y = 3 z tr(, X UJ lJ-o uJz lr-o uJ CL J(n I(J F UJo d d. Ftt dIt Lu t-X uJ =tuz zo tr LU -tI,IJ Fa tu OOoo ONEOoobnl =@dn.o = r-lo o t-o Ptht- f fr--, =q=<\>-u -===gj l/t L/1 --(5 -1 -@==. F x sH= ^.^ el 3,"a F ===FF€E 3is=S= =r=€"{iE= ===;fr===Ei==# =4====r! - O O O l..$ LJ (J J l-i -i ,--.: l-i = fr == =€ = E = += = = u.o < -.o <. -. t:lt-) |r+r It-l r-) |4,1<l ll-o CJ lrJ C'JEl&lJ-e ":, .o o C =oF c ai utF FU LU 6'd.o- .'. i tri 2>l ootlotr<l 9st =l 9Y.El eAz2-)l = <o Odl 5 i.,1 O '-f 6z :> A6l EF 9o., ''Il Ot 2d ,.i?:l l! .r ^- lll,^,I .:, = iii i o- Z -91 65; dE -tgFt O S I OIII (J - (J N t -Cr - (D- ?z ITJElUoozIFU d,FtttzoU tlJo- 9,o*z< U-rtt IZni-1 utF.zzHU+4ztoa tlt nJ,aY6;9O;H -l vt lJ ^k!!>.2i+;jio -s+is =vfr>rr./1qJ42=JJa.oS*F<YO!2fJ l!F?.d^(hH2ogo+s:14-r,Vfrd+z =F(9S;ct a{ H1?5,!IF7 F EgIE El ; gl iErx'e^i Fbn#EE E z* =Ei?E *r I *gf iis Ei Z i,i rq; al gI g ,i lg tijll E ria E I El iE g3 Ei E:l E! ggg -li gig ; g g1 E E ii ea n Hn i E I [i ig E i E E3 EiE lE Efi El E E rE EE * =' iI ili l= g;; si; i*i I i =gA1"E FE Es E;; iE sEi il# E:fi E E' #,.trl1,zlfiE 3?E Ei fiEE E1frss f,iE E.gE E3 EiE EI liH[ EEfuIE EIF EiE Ig A#ig Efi E* (r) t-llFoz J d. uJz uJ(, o FI t=l E] or! :f\ ,.(N s> >(E'tr> (;Y J a r') t- 'tr o) Xt! IU o IU(Jz TUo t, IUtvlel- :l $l f;l ql (nl el FI !l 8li Hlr l,o, I J d=lfEl #fuEH f . )9; \--l LUF -o -o o = - lz .l #l o-lolFl a)t iluJIolzlol 5l: HIJ ({l I _l ifr=a**Eli iO. E T :h ESTE 8c) F ; HH Jldi,' =H E F I gf lFfrg ?-j; i s EH E3nF #f; H'qEi,h ^t,^o F E f+2 H=H H q =r.Fsasgr isI :f; h=6.92 '4 9gEJ fi63o ;=6uu 6U:n* EEliF hpiri la =Y)<J ru r,n (j) cr G,oj d'O uJ +H= A Ez9= 1 : Fjor-i; = = z =6? # Iqd6n * =Gr =5J E r39fE E r!Ju tl't Z = Fl t/) u. p?H * AEfr E3.HJ E=g? aEg=o-6<(,/,) ? ie dg od ;IF hF PR HPE gE T 2E, lqd 3d f I5= +=o< cLd Fo- L^,^= *Yu.t : Lu = E (J =6l,=E SA S;'7P6? =-zU =U =3 Egrh 58> H> 2d ilf ,lol6-l JI HI F,l:l flolzl fih-l' (-) 9;2 o-u1 o H fiHlgAEi; $ EE = g E E= 2i =PH;* s3 * =9.f A = HEs 5 = ld. FT5H ?;..,=b d3zu :.,58> 5 .t- - JItlz Fz =d. JIL 5og o 5(J =2 F-Ix UJ Y(J ulo 'ulur ,,0-,€ /\ -/ Y| !," -F- E nl fiZ A 5 EIHfls trtF uJ = ='-' Fo- |th Fo_ +Xd irO.: H si liE P;=5 =2 =24 62?H gA 9s; il;J ,l {4r,Y I (9l2..,v =ztLY.ro>XF<ulu!o. z Eoz () J 9 2 tr uJJ IJJ I t z QrooorrENr oF coMMUNrrY otrootu*, NOTE: THIS PERMT MUST BE POSTED ON IOBSITE AT ALL TIMES ELECTRICAL PERMIT Job Address: 2039 SUNBURST DR VAIL Location.....: 2039 SUNBURST DR TOi^AI OF VAIL 75 S.FRONTACEROAD VAIL, CO 81657 970-479-2138 Permit #: E02-0206 Status. .. : ISSLIED Applied. . : 1.0/04/2002 Issued. .: 10/07/2002 Expires. .: 04/05/2003 ParcelNo...: 21.0110201009 ProjectNo : 7qj5?- o27t OWITER PIERCE, MARITTA PO BOX 1123 vArL co 81_5s8 License: Electrical--> 5540. O0 Lo/04/2002 Phone: COrqrRAcToR wHrTE RrvER Er-,EcTRrc Lo/o4/2002 Phone z 970-949-L403 P O BOX 1118 AVON CO 8L620 License: 145-E APPr-,rCAr{rr wHrTE RrVER ET,ECTRIC 't O/04/2002 Phone z 970-949-L403 P O BOX 1118 AVON CO 4]-620 License:145-E Desciption: INSTALL NEW LIGHTING,WIRING DEVICES AND BRANCH CIRCLIITS AS NEEDED Valuation: $30.000.00 FEE SUMMARY Total Calculated Fees-> S543 . 00 Additional Fees____> S0 . 00 Total penIlit Fee___> S543. o0 Payments----> 5543.00 BALANCE DUE----> g0 . 00 DRB Fee-> Investigation--> Will Call-----> s0.00 $0.00 $3 .00 TOTALFEES-> Ss43.00 Approvals:I€eim: 06000 ELECTRICAL DEPARTI'EI{m L0/o4/2oo2 DF Action: AP Item: 05600 FIRE DEPARTMENr CONDITIONSOF APPROVAL Cond: 12 (BLDG,): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPIJIAITCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in fulI the informalion required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with "ff f"tamnces and state laws, and tobutn" structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE TEIEPHONE AT 49 OR AT OtlR OFFICE FROM 8:00 AM - 4 PM, OWNERORCONTRA HIMSELFANDOWNET Oot OA Og rcvx0FYtn 75 S. Fronkrcc lld.Vail, Colorado E1657 05: 32p LJh i t'eo APPIJCATIOT{ WI RiveF Eleo?Fic, Ino s?o s4s 67.1s SIGT{ED rmit #: Electrical Permit #: p.1 97o.471r-2149 (Inspcdions) Contect et 970-328-8640 or Pdr@l# Parcef # (Required if no Dldg. permrt # is provided abore) gX o t I OZ_o I d-zi Job Name: li;nter sl -.,t/..JobAddrcss: 4trqlt*^$,unst Dn.,V; ( L$El Description I Lou ll Block: I Rting:Subdivision: ryrye^'?, €rce flticrllo- ftAaotess: fuu- tng .yu p [n;rrc:lngineen tr AEaress: 'Phorc: Detotlcd dcscription of wort: EntialI ne,-z li.t*l-i,q-, t^tiri*+ {cuitt->It t-W trtc'A C, r a.,'+^ n A+ nl-t_.1-.-.1_--y----_T-.v- WorkOass: Hew(') Addition( ) Remodcl (l) Repair( ) Temppower( ) Otnerl ; Work Typc: Intcrior (N) Exterior ( ) Both ( )Doee an EHU cxist at thb loq:tion: Yes ( ) No ( ) TyDe of Eldg.: Slnglc-family ( ) Dupo( (;Q Hutti-ramity ( ) Cornnreroal ( ) Redaurant ( ) sher ( ) No. of Existing Ot/rellinq Units in this building:nlo. of Acommodatbn Units in this builrting: IthisLrermit for a hot uJb: Yes ( ) No 0<) Db6a FircArarm'Exiar -_yEaTl No(,"-lt-ooesi@-tGiTu,tt. j AMOUNTOF 5Q FT IN STRUCTURE:ELECTRICALVALUATION: $ 3o,Oao- - COMPLETE 5Q. FEET FOR t{Ew BUITDS and VATUATIONS FOR ALL OTHERS (Labor & Matcrbls) CO NTRACTO R IIiI FO RI'IATIO t{ Ehctrrcal Contractor: L^ilwl e P,ivar €.1 cctu; c- Town of Vail Req. No,: lLtS e^ Contact and Phone r''s:R-il/ G cadta q?o- 4't 1 -ozzct * r r*.*r*.*r..o*{****r. irr* }l***.1*+r**r rFIOR OFEICE USE ONLY*.*rt,tr *r*l*+*****. r ***rr*r+r.**+rrrrr I :/.vrqryondbmj/dccper OWNER TOIVN OF VAIL ''*' O"*''U? 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 CONTRACTOR TH(ITJ ELECTRONIC SYSTEMS P O BOX s34 AVON, CO 8152 0 I-,icense: 112-S APPI,TCANT THI'IJ EIIECTRONIC SYSTBMS P O BOX 534 AVON, CO 81_620 License: 1L2 -S VAIL FIRE DEPARTMENT LL/Lt/2oo2 Phone : 970-949-4638 Lt/!L/2oo2 Phone:. 97o-949-4638 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A02-0070 Job Address: 2009 SUNBURST DR VAIL Status . . . : ISSUED Location.....: 2039 STINBURSTDR Applied. . : 11/1112002 Parcel No...: 210110201002 Issued . . : 12/1212002 ProjectNo : Expires. .: 06/0912003 sNowsToRM IJIJC LL/LL/2OO2 Phone: c/o rttRcAN CoNNELL vts ATTN: RF SALTIRE CT 20 CASTIJE TERRACE, EDINBT]RGH EHl- 2ET, SCOTLAND License: Desciption: INSTALLNEW FIRE ALARM SYSTEM Valuation: $1.800.00 't * t t **:t **,t'l* **'t'l * Electrical----> DRB Fee-----> Investigation--> Will Call------> TOTAI- FEES-> Approvals:Item: 05500 FIRE DEPARTMENT L2/Lt/2oo2 mvaughan $s0. oo s0.00 90.00 93 .00 $53.00 $s3.00 so.0o s53.00 $53 .00 s0.00 Total Calculated Fees-> Additional Fees-.-.---> Total Permit F€€----> Payments---------------> BALANCE DUE......-> Action: AP CONDITIONS OF APPROVAL *+*a +*altr)t**+:t+l aa +.}rt++a,tt* *:t't *a:r*+,1*:|a**:a t*r. *++4,1.:t1** at *a*,*:r1** art|*art!a a*:l:l t*t ++a*:r*t*l' a *l *:*'i*'t*rt ** aar*:| DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances ofthe Town thereto. REQUf,STS IOR INSPf,CTION SHALL BE MADE TWENTY.FOUR HOURS IN ONE AT 479-2135 FROM 8:00 AM - 5 PM. SIGNA CTOR FOR HIMSELF AND OWNEF 'l {' ***** ***t*+*** **********t *+* **** ********'t'} f ***t t +,tr * * + + + * * * * * * * * * * * * * * * * * *,} * * + * * * * + * * * + + {r* * TOWN OF VAIL, COLORADOCopy Reprintedonl2-12-2002 at09:22:19 l2ll2/2002 Stratement * * * * + * * * + * * + + * * * * * * * * * * * + + * '1.:i * * * * {. * * * * ** **t*****+**+* ******* **+*{.**+*** * +********,}*** ***** ** Statement Number: R000003487 Amount,: $53.00 tL/22/2002L1 :4? AM Palment Method: Check Init: IJC Notation: #15226lThuI Electronics Permits No: A02-0070 Type: ALARM PERMIT Parcel No: 2101102 010 02 SiIe Address: 2OO9 SI'NBIJRST DR VAIL Location: 2039 SITNBIIRST DR Total FeeE: S53.00 This Paymene: $53.00 Total AIJL Prnts: $53.00 Balance: $0. O0 't'i * ** + * *** **** * * *** * ++ * t * ++ * * * ++ * * * ++ * ****{' '} * r!'}+f * * + ++* ** ***{r+ ++ f f * **** * ** 't + + +** **** * * **** ** ACCOI,]NT ITEM LIST: Account Code Descriotion Current Prnts EP OO1OOOO31114OO TEMPOMRY POt^lER PERMITS l^lc OO1OOOO31128OO I^IILL CALL INSPECTION FEE 50.00 3.00 TOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 Qrro*rtu*r oF coMMrrN,- o.u,l|,ru.t NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M02-0176 3c'{rr( Job Address: 2039 SUNBURST DR VAIL Status . . . : ISSUED Location.....: 2039 SUNBURST DR Applied . . : 08/26/2002 Parcel No...: 210110201009 Issued . . : 08130/2002 ProjectNo , ?R.'pi ryXt" Expires. .: 02126/2003 OWNER PIERCE, MARTTTA 08/26/2002 PhONC: PO BOX 1123 VAIL CO 81_6s8 I_,i-cense ; COMTRACTOR LORTON PI-,WBING INCORP 08/26/2002 Phone: 970-328-5900 P.O. BOX 3535 EAGLE, CO 81_63 t_ IJicense: 210-M APPI-,rCAliIr LORTON PLIJI.{BING I}ICORP 08/26/2002 Phone: 970-328-5900 P.O. BOX 363s E;AGIE, CO 81631 License:210-M Desciption: INSTALLNEW BOILER SYSTEM WITHNEW FIEATEXCHANGERS FOR DOMESTIC HOT WATER. PROVIDE NEW BASEBOARD WHERE REQUIRED PERLAYOI,N Valuation: $15.000.00 FireDlac€ lnformation: Restricted: Y # ofGas Appliances: 0 Mechanical---> 53 00 . 00 Restuarant Plan Reyiew-> Plan Check--> Investigation-> Will Call---> s75.00 DRBFee---------->So . oo Additional F€es-'-----> # ofcas Logs: 0 # of Wood Pellet: 0 FEE SUMMARY a+'*t:t*tat'ta*:r:rtt*r**,t1*:t*****:ta+ta,*,1**:t:t**a:tr*a*rat*'l***:**t{'r SO. OO Total Calculated Fees--> 5378.00 90.00 Palments---------------> $3 78 . 00 BALANCE DUE----> $o ' oo So.o0 TOTAL FEES---------> $3?8.00 Total Permit Fee------> $378.00 s3.00 Item: 05100 BUIITDING DEPARTMENI O8/27/2OO2 GCD Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIEI-,D IIISPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPIJIAIICE. Corjl | 22 (BL,DG.): COMBUSTIONAIR IS REQUIRED PER SEC. 701 OF TI{E 1997 UMC, OR SECTION 701 0F THE 1997 rMC. Cond: 23 (BLDG.): INSTAI-,LATION MUST CONFORM TO MAI{UFACTITRES INSTRUCTIONS AND TO CHAPTER 10 OF Tyt]- L997 nMC, CHApt' 10 OF Tr{E 1997 rMC. Cond: 25 (BL.,DG.): GAS APPIJIANCES SIIALL BE VE}IIED ACCORDING TO CHAPTER 8 TERMINATE AS SPECIFIED IN SEC.8O6 OF THE 1997 I'MC, OR CHAPTER Cond:29 (BL,DG. ) : ACCESS TO HEATING EQUIPMENT MUST COMPITY WITH CIIAPTER THE 1997 I'MC AND CHAPTER 3 OF TI{E 1997 IMC. Cond: 3l- (BLDG.): BOII-,ERS SHAITIJ BE MOITM|ED ON FLOORS OF NONCOMBUSTIBLE CONST. I-,ISTED FOR MOI]NTING ON COMBUSTIBI,E FI-,OORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE AIIALYSIS MUST BE POSTED IN MECTaNICAI-, TO A}T INSPECTION REQI'EST. Cond: 30 (BI-,DG. ) : DRAIIiIAGE OF MECIIANICAIT ROOMS CONTAINING HEATING OR HOT-WATER SUPPLY BOIIJERS SEATJII BE EQUIPPED WITH A FI'OOR DRAIN PER SEC. LO22 OF THE 1997 I'MC, OR :-T::]"T-::lj;i---"-i--lTI--1-'-i-]--lT-l;**{.+**'t*,t*,lt,}***l||)lf|t||+'t+'|l*** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances ofthe Town applicable thereto. AND SHAI-,L 8 OF THE L997 TMC. 3 AND SEC.1017 0F UNI,ESS ROOM PRIOR REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADV SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF Y TELEPHONE AT 479-2138 OR AT OUR OFFICE FROM 8:00 AM - 5 PM. ++f**+t+******f+***+f+**++{t***t**++****++*+**{'*'l****++++++*** f+*****+***+*** ++ f * * ** * * * *** * ** TOWN OF VAIL, COLORADO Statement ** ******r* +*****{.{.* ** *,}**** * + * * * * * * ** * * * * * + * * *** * * **** * * * *+ * * * *{. * * * ** {.**** {. 'lt * *{.'1.* * ******1. ** ** Statement Number: R000002992 Amount I $378.00 08/30/200211:25 Alt Palment Method: Check Init: LC Notation: #558?/Lorton Pluribing Permj.t No : M02 - 0175 IIT)e : MECIIANICAI PERMIT Parcel No: 21011020L009 SiIe Address: 2039 SI,NBURST DR VAIL L,ocation: 2039 SITNBI RST DR Total Fees: 5378.00 This Palment: $378.00 Total ALL Pmts: 9378.00 Balance: $0.00 + t**+***** *** **'1.,1**ltt{. * *** * *** t * **+********* *+ *+ * ********** ** **'lt +**** t**+* * + * + + * * * * * * * * * * * + * * ACCOUNT ITEM LIST: Account Code DescriDtion Cunrent Pmts MP OO1OOOO31113OO MECHANICAL PERMIT FEES 3OO.OO PF 00100003112300 PLAN CHECK FEES 75.00 lic OO1OOOO31128OO I,,]ILL CALL INSPECTION FEE 3.OO 75 S. Frontagc Rd. Vaif, Colorado 81657 ''(t Permit will not be accepted wiUrout tne fottowingr Mechanical Room Leyoutlni:al Room Diliionr and Gas CONTRA EIVED G22?00? .cOM.DEV. Town of Vail Reg. NoJ €T\s l='ZB--6c\q:r @MPIETEVAI r&Materiats) JobName:\ \->-*.<-..^. LUL Zc)-s'\ -r\NBOe..ji- ,€$'iEtt.*gd 3+r-te3--sYs1a1-ItST \\ grile-<. Rc^i.D€ \IIed lork Cl.*' N"* ( ) Addft eturation bd Repair ( ) other ( ) Boiler Location: Interiort<l erturio,r l 1E[!,1 1 Does an EHU o<ist at ttris location: Ves ( I flo t Ty". "f Bldg' S[ngl.-f"rrty ( ) Drpq${ No. of Fristing Dweling Units in tnis OuitOinol--E No. of Accornmodation Units in thb building: Nofl-ype of Fireplaces p.poueO Wood Burning (NOT ALLOWED) ls thls a con"e,s :fi *:ttt:t***rl.:f ****,1*****:*** *e^r arrr -- '***III1*FOR OFFI t,t,trl.rt*t(*:r** F: /Gyartona/ fomj/ mGchpcr||l usE oN LY'r'ft *,f * r *,t *,ft rfi :t * :rJt SHEET NO,f, i\ LoRroN pLOrBrNG, rNc. l1J #?bhi?r','ss.,CALCULATEO BY CHECKEO BY Eoqcbtrsq] 3! oo€.\|+att+ (o ro otto z al E tro EI c, a It EoIL C)o tro Eo CL oo ElI.btr .EaoooN o CD c.oo a f,\io oot4) \o CD(9 \N r{) o\rf) c{ o N )r.' c.i oo t o (r) !o ol r) )i ro N o N o\i o oi rl) o f o !() trj o cr o J D L Ee(,Io d € C' a, J oc\ E(,g ot C o eaaq I = E $e (t) z.otr() l!J lrJ $J A M o_,oglu cll PEI0 -31 u| C' o oo Naoo-oG| €! Eoot oo D oro 1- o(ori oF- ai ooro @ <) o @ td o(r)oo oo @o o C.l oo oooF- q,(\| tr (I ! .A{,3I or{} N olo Ci oe ro o rr) orod oo(Joo oo oo o C\l oo oooF- ao{ll rt, C' Ec oro F- oq oo N oo |{) oro oods oorooo ooto ct oo @o oor oo oooF. !tFo eoc36J ra) F- oo F- ood o roqo oo c.i oro oo q) o oc{ co oooF- (otro Ga o3o oq I.- ooo <>o oi o |r, ootf)(o @ orJ) ct c.{ o ooo l- Naae, o o(, n o,o o(, t\ ood oo (r, oF. N(9 orD(o oodc! olooo o CO o f- N€€- ao e0o D oz otr) 1* oo CJ oo (0 ooort oolo(o o oo @(.) oolrtoo oo q) o o CO oo oo F. $\o Egt oat6oe. C tiE 3 Eoc, G a E =6oe. G o aatl!0{o a Cr.!t! 6 o C'{ ct t tFI a =Eoo e ut (lo =Eat|] 8. ul C E6 .l o (! A? o(t o(t a! o 6A ! o(t o (l€|r ED =oo b tq LItt o a,E oE E tE lt (D s e,*EoF ooEg eIo g -l 6f cc' Hg'-963f sl €II -ecl o!te = *l rat I9l al _aN 3l TI EesoCI E Pc.9ooa €r)66 tr 3, -(sl =EY €E() FE .F Spr E ril! figE r-91 FI tsIJ , g tt!l oo .E EDcttl .l €l €ltl:l-ol!olzl t:o EIY' E ai Eoz 4lo l- s*.ri$t \X' $t .S tai PTF \ ,\ tr-r FT l1\ -\ tils li!!r{ 8l gg UI oo(tctaot tc rat €!tro z .96 co E (9 tro g o CL oo tr l!>E .gdoooG| o <D CLI(, t{ tt u? $ lr)ri Et cc Jtc Etoo -g c !toc JIttrtt t .g $a ta o I3A 3 = Etoq (t) z.otr() Irl ltl CI A M o-,6glu.ll CI r-l-; ttl ,.rr- 6lLT JI o 6 o oo? 6a(tr\C'co C G "go F g E E Eo) E Ec. € =F g t 66 5IiI€tl ooo IJ GIL e a o.! ot a. a3oJ = =€oI &xl|l o(,ctt 5 E aa 8.xltt C E oJ o |!Aoo(, o IJc\co tIIo(t o oCttoc =oo b (,ct! Ilt o(t6 Eo ! =c L ql og It oF oEc R F E. ot-l a E oCr -E olo. url l-lIrt9 *I E il g cl=N< 8l sg rn 9rorl TI Ees ata Eg c -9U'oo o€c)EZ-o tr 3' I El 5 d'() 6R()E$) ': (f)3 ()-,E-JgId Fjl ! ulglE --91 9l ts(, iiitlc € coF EUIEou oll!o = o EalatIJ Et g -s3 o Eo =3o l- sD-& s, sl .S Fa1\p rF \.F L\ sH\J!r{ Eoqg c6q =3 3 coro clrtcot € ro oItlo z o E co E(9 a, La g| EoIL ctct c .9 Eog o(, tr tr.>cg ancooG| o o L ILco f? it q rf q (r) tr)s(o Nro o $ q d rf) N o c.,i (, @ od ) o tf) q Y N o q c\r o o) !| J !, L Eg g o + =c a) clc{o lt E(,g oe +Cc a Ioc. I. Eo () Eo CIzotr()u tu C) A M o ill gt o3l trEl u, 6 o ;o G.o\oo o G o oo !t(o Fait Ertr c 5 oq F. oro('i ood c{o{ at(o ooroqo oor-N oolooo o{o oo oo F- ooq€ trc,tr.J oq F. oot- (o (o oC)()qo oor- oorooo o(\ qo oool,- tt!t Et o6-cc D oq F. o (o oq o * ooro(oo (r, C.l o(oo ooC'(D o o(o C) o oF. (D e e tr ,rI o @ F- oo ci oo (fJ oq oolo @o oc (Y) ootfjoo o@ o <) oool: o) 6! at EooI EDg = ooi o|r)€ oo (., (r)() CO(D (l @o oo tri(o oota)oo oo 3o o @ oo oo c;F. 6|ol(o G, g Eo o- I e. G G EtJ g e, E;€: F EE GE!;oi 0€ !t .J o IJatltl a(, d t a oJ G Eoo UJ o |,att ! E6 L I! G ocI E6 Ea!!. ? oo 0ocltto q o.g (, o uctt CDc o() b a,otl olt o t! o t! lt o t! oo. EoF o s Fg oI -l Gf atCl €el loltil9 *l E il g o.=N< 0 EY'g 9ro\l Tlg eIoa Eg C CD v,oo ooE$):z-o tr 3' { El 5sq €gu E$) ': (t)Eqk -El5 Filx <Jl5 rri trl r, :- t5l.s J- =l FI Fu at E!tIt oo .EOctll golFIJ ElcoIoll!,o = o EaUIDU gtcl =tnt Eozoo l* s -€ $, H .S c'rITF \s str\D t--rfl 8l dtUI Eoq trItrg q '3; co(o(\l !not (o 5 €Qro 2 o6 trtl,c(, I o o Eolroo co Eocl ooclr E G a,oooN o .D CLoo t)rt q s lr) (o Dt:'| ot-(\ o c.i c\l ) c o (rJ l()o o os ro !, P L !e(tgocl -Ec arr e,trJoc l|. E {a G oI|!G =3 = E(r .Eoa (l)zotr() ltlJ l.rl C) A M 8erttl ql(n =l-: ol ^- 6l lr-r fl Is 3 EIo crl(D t\_ C'o o o E oo etro ra o oo! o oa! E ooo oo (.) C-l oF- t.i ooro(oo oo(o (v) o|r,oo o (f) o o6 o ct oF' ot c (! D o o au E ooo <><) (.)ol o(\l ci C!a (f) ooro(D o oo F.+ oorooo (") o o CO oo oF- 0 o- ac C -E.9o- 6oE C E oJ E E t C3;t 5 E Et I sgl (:t {o ot atetta G(t € o 6 a3 IDcJ F ! E Exul o CIC 5 ! s 8.x TJ g tItq(tJ .e cA E o(, (Ja ,9 lE! I =oo ogtllLo =co o 6lt 8tt o(,(! o c lt iu 3 ot 6F tEc s Fg grt*l F coFg-968f,ol 3l'l Eo -cEI o! € *lurlel a(, I _aN 8l ji # 3t TlI €oc\ Eg c ED Eo sE(')66 tr 3' {il =EY €R$ EEa o-,IE JgI6 Ejl € Fg FIt(, rri at) ett! oo .E CDc.la €l €l 5l !l 6 Eavl3u d Eo =€o l* s --t6)" h $l \)\Fl ti\Irts \.t tr\ NItr= :.-iS,--\-tr\m t-sl oheating o rne$maxn vrroDENs 2(t(' A compact wall-mounted condensing boiler with lnox-Radial heat exchanger surface and Matri X-compact burner Ga s-fired condensing hot water Rared inpur: 25 to 230 MBll vtroDENs 200 (D With Inox-Radial heat exchanger Gas-fired condenslng hot water heating boiler Rated input: Standard heating boaler: 25 to 230 MBH Combination boiler: 25 to 9l MBH A high{uality and reliable condensing boiler. The newly developed Inox- Radial heat exchang€r surface of high- alloy stalnless steel and the modulating Matrlx€ompact gas burner make for maximum energy usage with minlmum emissions and small space requirements. The bc.|efifs rt r glence: I The rno.Elating MetriX.cornpect ges b|'rEr offers extremely low emissions: NOa: 8.9 ppm {air-tee), CO: 5.5 ppm (air-free). Vitodens 20O meets the spocifications of the German "Blue Angel" envlronnrental certificate, Swiss clean air regulauons and California regulations.I ow compsc{ hFrdedal he.t etGlE!€Er su ace made of high- alloy stainless steel designed on the lamanar heat transfer principle ior high operational reliability and a long service llfe: - The radial design of the high-alby heat exchanger allours maximum performance within a small spae.- The defined gaps between coils produce a laminar, high-intenslty, efiicient heat transfer.- Rectangular design of coils maximizes the coil gap length and ensures marlmum utiliza on of heat exchanger $trface,I AFUE |? ro gt.ZX. I Smooth high-alloy stainless steel surface and uni-directional flow of nue gas and flue gas condensate enhance the s€ff*aning efrect on t D lElt erchangs?.I Low powec consumptirn due to variable sDeed DC blower fan and variable spe,i)d heating circuit pump.I The cornbinstlon boiter modol (25 to 91 MBH) with integrated stainless steel plate heat exchanger produces dorEstic hot water efnciently and at even tempefatures.f Us€Ffr ieDdy, indoor/outdor Gornfiort cdttrol, built-in and prewired.I Easy to alEta[, mrlntain and sGruice tl1anks to the uniform platform strategy based dr the bualding block principle with plug-in connection s)Etem. surface hor-n dirl lr.t .[drrng; t|rLca ffirhingUatix. comFct gc bunI] Q=gt^** '/J']i]]J15.'!']i l, I l40li t r.1f1 ir L r iiiJll 712-0ti0 Vitod.rc 2m -r cofnpact rrall-rrunt d con tflrirg bdh I Th€ entire water flovv system is integrated in the .qE-plate In the rear panel. All components are easlly accessible.I Plrglan cornectiro sll3tcm: All sub- assemblies can be easily rerno\red from the frorn without tf|e need for sp€cial tools.I Balanced flue design with sr*f. rcgulati€ gsr blrner and self- calibrathg combustion on initial sbn-up, as well as permanent self- adjustment for reliable operation and rnaximum performance.I Models WB2-2'|C, -2{ and -32 feature variabb spoed, weather-rcsporEhre Kil-BUS pump for maximum comfon and energy savings. ffi@ il.trix.comPlct gG hrnar lrpr.RJirl hat .!dr|ngir surfaca VITODEI{s Modet No,1l-1,1 ftd lt.a ]|qr t{atrral 96 MBH 31-121 55-t72 U|Jld p.opane MBH 3t-112 55-1t5 Tlrl dh||.b DxWxH € E (J E rtdcr tr.hes 15 r rgtr 35r, 16 x l9* x35h 16 r tgltr35lt 2ll x23tt r35h al r231t [35tt Technical lrformatlon srbJe.l to d|ange wtthout nothe. Phose lll@'s ollor.r,rs For production uroter u.lit ths-; exclusive dosign the continuous oF domesti< hot .-*..,1.]'-)""{ o stru TR Serics o ^^, HL Series Con ction Spccificotions 0 {i,a) (., 0 I d'\ c o '( Phase IIIo is tested in accordance with the standard (ANSVUL-174, 1989) (CAN/CSA-C22.2 NO. 11GM90) anrJ is cerrilierJ by ETL. A. Inner stainless steel tank I. Thermostat control B. Outer steel tank J. Temperature gauge C. Polyurethane insulation K. Thelmostat femote sensing bulb D. Boiier water supply L. Air vent E. Boiler water return M. Electrical wiring plug F. Hot water outlet N. Thermometer remote sensing bulb G. Cold water inlet P. Vinyl jacker H. Enameied steel jacket Q. Auxiliary domestic connection (for recrrculation return or relief valve) 6" I (^. 't t r1 I'l Suporior Design "Tonlr-in-Tonk" Technologg ,1| When combined with any boiler, the Phase III@ TR and HL series indirect water heaters provide the most efficient hot water heating systems avail- able today. Phase IIIo's advanced technological design featules two concentric tanks: an inner tank, consructed of 1007o high quality stainiess steel, contains domestic water and an outer tank, constructed of durable carbon steel, contains boil- er water. Water in the inner tank is heated indi- rectly by circulating hot water in the outer tank from the boiler. The unique suuounding heat exchanger pr.ovides a much more even distribution of heat as compared to a coil type heat exchanger. Indirect water heaters with coils are morc suscepti- ble to isolated cold spots in the domestic hot water tank which can lead to bacteria growth. Coil heat exchangem are also more susceptible t0 liming. These conditions do not exist with the "Tank-in- Tank" desien. t,f, Ouolitg, Perfor o mo nco ond Reliobilitg The Phase III Indirect Fired Water Heater provides the convenience and comfort of hot water whenever you want it at the lowest possible cost. High EJJiciency, Low Costs Phase III indirect fired water heatem, when combined with any boil- $ 600 er', oflel domestic hot water supply rates and operating cost efficien- $ 500 cies that are second to none. $4oo Pheue III Indirect fired water heaters can save up to sOEa or more off $ 300 your current water heating bills. Plus, since phase III doesn,t require a flue and has no bumer, your maintenance costs drrcp dr.arnatically $ 100 compared to conventional water heaters. $ l0o $0 $ ?00 +Based on the following enelgy cost: - Gas: $ 0.79lTherrn - Oil: g O.87/Gallon - Elecu-icity: $ O.09/kw/Hour Water Hcater Installation & Operatirrg Costs Indirecl Gas Oil Elecrlc Fircd Frrcd High Pe(brmance at lnwer Costs Ever.r with a slightly higher initial purchase price, the total cost of owning a Phase III Indir.ect Fired Water Heater is significantly lower than a conventional water heater over a fifteen year period. Also, Phase III exclusive self cleaning, self descaling design prevents the build up of miner.als and lime that can reduce per.for- lnance. Long, Term Dependability and Quality that Lasts Unlike conventional water heater.s, the lower temperatulr differential betweeu the Phase III heat exchanger and rhe clomestic hot water. dra- matically reduces wear. and tear on the system. The avelage life span of a Phase III Indir-ect water heater exceeds 20 years! That is two or three times the average life of a conven- tional gas, oil or: electr.ic water heater. *Basecl on household of four pelsons and aver.age heatel life/cost. $ t2,000 $ 10.000 $ 8,000 $ 6.000 $ 4,000 $ 2.000 $0 Iudrrect Gas Oil Eleclr. Fircd Fired 30 Yeals 25 Yean 20 Yeals l5 Ye.u s l0 Year s 5 Years 0 Yeils Indircct Gas Oil Elecrdc Fired Fired *Based on normal lesidential usage. Life ot'all units will be leduced wherc warer quality is poot: Water Heater Annual Operfltiug Cosa (Farnily of four) Water Heater Avel.agc Life Increased Comfort - Never run out of hot water again You will never have to wait to take that second shower again ! Phase III@ provides up to 3 times as much hot water than con- ventional water heaters. It also recharges 3 times faster. Hot water when vou want it. What could be better? Here's why Phase III@ works faster and better: When the Phase IIIo thermostat in the inner tank calls for heat, the boiler and circulator start. Boiler water is circulated around the outer tank and 0 min. +Based on a 90p rise in water temperature and typi- cal water heater performance. 200 min. 150 min. 100 min. 50 min. 0 si2 ?o ),o l'o h ot d'f' t . lr \ ,!r .t heats the domestic water in the inner tank. After transferring its heat, boil- er water is returned to the boiler to be re-heated. When the thermostat in the inner tank reaches its pre-set mark, r, the boiler and circulator shut off. f., rl ,-t Phase III@ operating cycle Cold Start (pump off) Recovery Start (pump on) Recovery Completed (pump off) In Service (pump off) f)' The multi-position capabilities of our HL Model makes it the most flexible on the market. Installed vertically, either in typical freestanding floor position or on a wall, or horizontally*, Phase IIII@ HL Model heaters can solve any installation problem. * Available with an optional floor mounting stand. Phose lll@ lnstollotion ,.1|. Cold Water Mixing valve 3 Cold Water Inlet Phase IIIo water heater (t) Optional devices may be required by local codes. Note: The recirculating connection is not available on the "HL" Series. 1. Shut-offvalves 2. Circulator 3. Flow check valve 4. T&P relief valve 5. Unions 6.Backflow preventer or pressure valve(*) Expansion tank Drain valve Thermal expansion tank (potable) reducin 8. 9. };rys_y# Triangle Tube/Phase III Co., Inc. Freeway Center - 1 Triangle Lane -Blackwood, NJ 08012 Tel: (609) 228 8881 - Fax: (609) 228 3584 E-mail: Sales @triangletube.com http://www.triangletube. com Member & Group ? lrion/ltc Vrophicsffi (*) This fitting can be used as a renrm connection if circulated domestic water is required. It can also be used as an altemate connection for the relief valve. Performonce 1|. Product Sp O ecif icotions ,.1|. Stondord Fcotures Durable, comrgated stainless steel inner tank Steel outer tank completely insulated with 2" of polyurethane foam (TR series) or I l/4" flexible polyurethane covering (HL series). CFC free. Baked enamel steel jacket for TR models and vinyl exterior jacket for HL. TR Serias Conditions: - 200" boiler water supply - 90o temperature rise - Forced circulation - Vertical installation HL Series A A A Factory supplied automatic air vent A Complete control system includes: . Adjustable thermostat . Temperature gauge (TR series) A Limited LIFETIME warranty residential A 15 year warranty commercial $ i1 i.i H E T I IT A o wreluANN vtroDENS 200 wall-mounted condensing boiler 25 to 230 MBH/7 to 67 kW Gas-fired Technical Data Manual Model Nos. and pdcing: s€e P ce List Vitodens 200 WBz Serl€3 cEs+ired Wall{tount€d Condan3lng Boiler with modulating MatriX{ompact gas burner {or room air tamperatur€ indsp€ndent operation (using a diract vent system) For Natursl Gas and Liquid Propane Heating intrrt NG 25 to 23O MBH 7to 67 kW Heating input LP 25 to 214 MBH 7to 63 kW VENIHED vftrFtt h,lt arif.tr {b 5167 472 vl .0 05/2002 ffi Product Information vrroDENs 200 The Vitod€ns 2OO is I high{uality condonsing boiler made of stainless st€el, d€veloped in accordance with the latest achiavements of the condensing boiler technology industry. In terms of optimal energy usage, for exsmple, the Vitodens 2OO is uncompromising; Thanks to the innovative condensing technology ot the boiler with modulating Matrix{ompact gas burner and th6 especially d€velopsd Inox-Radial heat exchanger surfac6. made of stainless steel, the Vitodens 200 reaches an A.F.U.E. ot up to 94.2%. The benefits at a glanc€: r Gas-fired cond€nsing boil€r Standard heating boiler: 25 to 23O MBH/ 7to 67kW Combi heating boiler with DHW production:25 to 91 MBH/ 7to 27 kW t A.F.U.E.: uD to 94.2% r The modulating MatriX.compact gas burner oflers extremely low emissions. with No,: 8.9 ppm (air-free), CO: 5.5 ppm {air-free), the Vitod€ns 200 meets the specifications of ths German "Blue Angel" environmental certilicata, Swiss clean air regulations, Calitornia regulations, as well as th€ most string€nt requirements worldwide of the Hamburg climatic protection program "HeatirE + Solar". . Low electrical polver consumptaon due to varisble sp€ed DC blower fan and variable sp€ed heating circuit pump (variable speed pump not available on all models). r The Combi heating boiler with integrated stainless steel plate heat exchanger (integrated DHw ouick-system) and comtort control oroduces domestic hot water instantly, tsificiently, and at even temo€ratures. r Comfort controls; room t€mperature dependent or weather-responsive with integrated diagnostic system and new control functions. r Easy to install, maintain and service thanks to the uniform platform strategy based on the building block principle with plug-in connection syst€m. r Self{alibrating flue gas sdaptation: no adiustments are necessary due to automatic adaptation to the llu€ gas pressure drop under varying operating conditions. Vitodens 2O0 - Models WB2 1 144 and 15$O 172 MBH to 23O MBH/sO kW to 67 kW F. F. Prodlct may r|ot bo .x€ctly as illustrsted Product Information Cross-Section C.l l-- It-(o (t i'i rlf: : 'lrlrffi !ffir$i{' Of, ffi ffi ".,.1- ..-.J' " Vltodons 20O, WB2 6'24C (25€1 MBH/?-27 kw) shown' Product mav not bs oxactly as illustratad. 3 Technical Data Combi Seriss Standard boilol Bdler Model Model No.wa26-24C wB26-24 wB2 832 wB2 11 44 w82 15.60 Natural gas CSA inpul MBH kw CSA ourput/DoE MBH heating capacity kW Net l=B=R ratinq't MBH 25-91 7 -27 2281 o-z+ 7n 25-91 7 -27 2241 6-24 70 37 -124 11-36 33-1 12 1 032 97 55-172 16-50 49-1 53 1444 133 80-230 71-205 21 €O 178 Propane gag CSA inpur MBH kw CSA output/DoE MBH heating capacily kW Net l=B= R ratins't MBH 2541 7 -24 22-7 3 OJ 25€1 7 -24 63 37 -112 1133 33-101 1 0-30 88 55-155 1 645 49-r 38 1440 120 ao-214 2353 71 -191 zt-50 166 Heat exchanger surlaco area tt.z m2 4.22 o.76 8.22 o.76 9.91 0.92 20.91 1.94 20.91 1 .94 Min. gas supply pressure Natural gas "w.c. Propano gas "w.c. 7 11 -f '11 7 1l 7 1l 7 11 Max. 9a3 supply prsssure'2 Natural gas "w.c. Propane gas "w.c. 14 14 '14 14 14 14 '14 14 14 14 A.F.U.E. %94.2 94.2 94.1 94.O 94.O Max. power consumption (incl. W integrated pump tor WB2 6-24 and 8-32) 120 120 85 85 Weight lbs 159 72 143 165 75 198 90 198 90 Boiler water contenl USG Itr 1.1 4.0 1.1 4.0 1.2 4.6 2t 11 .7 21 11 .7 Integrat€d PumP tlow lale at 6.6 lt./2 m head Pressure'3 GPM Itr/h 4.6 1050 4.6 lo50 1050 Boiler max. llow rale'4 GPM Itr/h 1 400 6.2 1 400 7.O 1 600 15.4 3500 15.4 3 500 Max. opsrating plsssure at 21 0 'Fl99 "C psrg bar 45 45 45 3 45 45 Bdlsr connections Boiler heating supply and return NPTM Pressure rsliei valvo NPTF " Drain valv€ (male thread) Boiler supply/return for indirect-fired DHW storage tank NPTM Tt v. v4 v. % v. Tt v. 1% 1 1% 1v. % 1 1Y, Vitodens 2OO 'I Net != 8=R rcting based on piping and pickap allowance of 1.15. '2lt tlE @s s$y NaJIrJre exce# tlg nnximun gas swty presFnxe vahe, a srynte gas presue rcg.htor rmm b irFita ed rffiteam d tlE heatip systffiL .4/111 ynp roatianl wed sct to | OO% ftow capacity 27OO rW), se€ CdN A&res O45:065 in tlE vit&rs 20O &af{P/SeNice h&rrctims. Amp factoty &fat-lt setting is 650/o llow capcity (,7@ Qrn)' '4see 'Typical ftow rctes fot vitodens 2oO, wB2" on page I in this manual' N F.. F- @ lr) Model No. Vitodens 2OO Standard heating boiler wB2 15€OBoiler Model Dimonsions Overall depth Overall width Ov€rall height Height with flu€ gss elbow (acc€ssory) Gas connection Standby instantaneous DHW plato heat exchangar ol Combi boiler'5 Water content DHW side hsating water side Connections DHW and DCW Max. op€rating prsssure (DHw side)'6 DHW supply temp. range Continuous draw with temperature increase trom 50 to 1 13 oF/lO to 45 'C Draw rate range Flue gas Temp€rature (at boiler return water temD. ol 86 oFl3O oC) - at rated full losd - at rated partial load T€mperature (at boiler water return temD. of 140 "F/6O 'C) Average condensale flow lalo with natural gas and - Ts/Tn = 167/140"FnSl6O'C - T5/Ts = 1g47g5oFl4Ol3O 'C condensate connactlon'8 Boilsr llue gas connection' Combustion air supply connection'9 tnches mm tnches mm rncnes mm IncnBs mm 21 1A 540 23v, 600 35v, 900 47% 1200 104t40 95/35 l5AnO 4.8-5.8 't8 -22 6-7 .4 23 -28 NPTF " USGiltr USG/ltr NPTF " psig/bar oFloc GPH Itr/h GPM Itr/min .F/.C oF/"c "Ffc hose nozzle O in/mm a In/mm outer @inlmm Itr/day USG/day Itr/day o.8{.9/ 20 -24 4%t110 6/1 50 c',t + F 'SMinimum pressure for domestic cold water connection I ba l5 psig. '6see Vitodens 2OO System Design Guidelines for DHW sizing charts. 'TMeasured flue gas temperature with combustion air temperature of 68 oF/2O oC. 'SReguires 1"/25.4 nm tubing. See Vitodens 2OO System Design Guidetines for details. '9Do not exceed maximum equivalent tength of 20 ft./6 m as indicated in the Vitodens 2OO System Design Guidelines. A m.ximum ol tlrre€ elbows may be installed in the vent system. Do rct attempt to vent the Vitodens 2OO veftically. Do not attempt to common-vent Vitodens 2OO with any other appliance. Venting material to be supplied by Viessmann only; venting installation must include Viessmann protective screen! See lnstallation lnstructions of Vitoderc 20O Direct Vent Svstem lor details. >For infomation regarding other Viessmann System Technology componentry, please rcference documentation of rcspective product. 406 19 y. 500 900 44 '| I16 21% 540 23% 600 35v, 900 47 Y. 1 200 to 406 19% 500 35y, 900 1116 o.'18/o.70 % 1 50/10 100-1 35/38 -57 156 95/35 91/33 149/65 2.94 11-15 3.7 -5 14-19 8-10 2.9-3.4 11-13 o.80.9/ 20-24 o.80.9/ 20 -24 0.8{.9/ 20 -?4 4%t110 I Vitodens 2O0 VitoderB 2OO up to modsl wB2 832 o o E o o E E E b roFo, q! F , '6 I E Eooc, n) ro 7 .4" 1187 mm 9.8",/250 mm 12.3"/314 mm 1 5"/380 mm 19.75"/5OO mm (Width) lnstallation on linishod wall Legend AV Air Vent BD Bciler Drain BR Boil€r Rsturn BS Boil€r Supply FFL Finished Floor Lovel GC Gas Connection PRV Prossure R€lief valvs Ody lor Comti heating boilor DCW Dom€stic Cold Water % " DHW Dom€stic Hot Watsr %" Only lor atandard hoailng bollerDR DHW Return 7a" DS DHW Supply %' q (\ F F. @ Vitodens 2O0 Vitoden! 20O mod6l WB2 1 144 and up Leg0nd AV Air Vont BD Boiler Drain BR Boilor R8turn BS Boiler Supply DR DHW Return %" DS DHW Supply 7r" FFL Finishod Floor L€vel GC Gas Connection PRV ProssurB R€list Valve @Eco E E o ; F ; E (, F.o @F 175 mm 7.4" 1187 mm t 1.8"/3OO mm 16.25"/41 3 mm 2O.7" 1525 mm 23.6"/600 (Width) q (\l ri F u) Technical Data Recommended Minimum Service Clearances Diaqram is not to scale. Waterside Flow {primary circuit} The Vitodens 2OO is designed only tor closed loop, forced circulation hot wat€r heating syst€ms. Pressure drop (pdmsry circuit) ol Vitodens 20O 268 237 '1 9.7 6 16.4 5 Minimum Clearances to Combustibles AL -- Alcove CL = Closet ' I Befer to the Vitodens 2OO System Design Guidelines lor details on the Vitodens 2OO Direct Vent SYstem. PressurB drop up to model WB2 8-32 Pressure drop model W82 1 1 44 and uP @.9 E13.1 E g.e E o.o e> 3.3 ,B,:o ,] EU o '1.'l 2.2o 250 500 Flow rate 4.4 1000 6.6 1 500 8.8 2000 11 2500 13.2 15.4 GPM 3000 3500 ltri h Typical Flow Rates lor Vitodens 200, WB2 AtfoiLP Outoul {LGl atu/h 73 000 73 000 101 000 't38 000 191 000 20 'F rise (GPM)7.3 7.3 10. 1 13.8 19.1 25 'F rise (GPM)5.8 5.8 8.1 11.O | 9.J 30 'F ris€ (GPM)4.9 4.9 6.7 9.2 't 2.7 Use standard friction loss method for pipe sizing. Observe boilet maximum flow rate limitations. lf system flow rate exceeds boiler maximum flow rcte ot if system flow rate is unknown, Viessmann strongly recommends the instaltation of a towloss headeL See page 20 fot lowloss header information. 8 q ct F- F.(o n Top Front Rear Left Right Concentric vent pipe" I O AL, CL o AttorNG OutDut ING) Btu/h 81 000 81 000 112000 153 000 205 000 20 'F rise (GPM)8.1 8.1 1 5.3 20.5 25 'F rise (GPM)6.5 6.5 9.O 12.2 1 6.4 30 'F rise (GPM)5.4 5.4 7.5 10.2 't3.7 Vitodens 200 Heating Circuit PumPs Heating Circuit Pumps Vitodons 2OO uo to model WB2 8-32 (residusl head pressure of built-in variable speed pump) tv.t o 16.4 5 13.1 9.8 1 EU 2.64 3.O8 3.52 3.96600 700 800 900 4.4 4.84 5.28 1000 1100 1200 6.6 1 500 o.to 1400 With gimp rotatjonal speed s€t to 10O% tlow capacity {2700 rpm), see Codirg Addr€ss O45:065 in the Vitodens Service kBructbns. fump tactory defsult seftir€ is 65% fbw capacity (175O rpm). G PIV Itr/h @ qr 6.6 o ^^a.r.o o. 0.88 1.32 1.76200 300 400 Flow rate 2.2 500 1 300 7 .O4 r 600 vitodens 2OO mod€l WB2 11-44 and up (heating circuit pump, f i€ld supplied) Hkd I'r,jJ e-l 6-1 o- 5- t- c- IMPORTANT Rrmo seleclion ]Ir|st be based m accurate system flow ard fessura drop calcdatiors 0rrc1. DHW rinr€I Messrnam offers a variety ol prewired Grurdlc ciqlatir|g putrps whch rnest typical VrtoderB svstem iGtdlarion loqjrerBnt& Se€ Rbe List tq o.d€r inlo.Illatiq|. The lotlowirg prewired Grurdfc pumps arB availade for oporation with thB Vitoders 20O, WB244i6O boil€rs: r Model UP 26-99 F r Model UP 43-75 F r Model UP 26-96 F r Model UP 26€4 F Please reterence corresPonding oerformance curvss (1-4) in the chart to the left. 01234 Perfomance chaft couitesY of Grundfos - c{ F.rt F.(o ro l0 Olflf,hl DHW Production DHW Production Planning With integrated stainless ste€l plate heat exchanger for instantaneous DHW heating {modgl WBz 6-24c only} or with DHW connection lot OHW production via a stand-alone DHW storag€ tank, the Vitodens 2OO boiler series offers the right solution lor eveay neeo. Options + = recommended O = recommended in ceatain cases - = not recommended Various factors must be taken into account wh6n d€signing ths hosting system, and when deciding betwoen the Combi heating boiler with integrat€d OHW production 8nd the standard heating boiler with DHW production via a stand-alona DHw storago ta nk. Such factors 816: r DHW requirement, l6vel of comfort and convenience r Number of draw points r Distance oJ draw Points trom th€ boiler/DHW storag€ tank r Syst€m retrotit I Spaca requir€m€nts q F F. G8s-tked Combi boiler with instantaneous DHW heating Gas-lired standard h€ating boiler with stand€lone DHW storaog tank DHW requirement, level of comfort ard convenience DHW reouirement for an apartment ++ DHW requirement for a single-family house 0 + Central DHW tequiremant tor a multi-lsmily house oecentralized DHW requirement lor a multi-family house + Number of draw points One draw point +o S€veral draw points, non€imultaneous usg o Sev€ral draw points, simultsneous use Distance of draw Points from the boiler/DHW storage tank Uo to 23 ft.n m (without DHW circulation line)+ With OHW circulation line System retrofit DHW storage tank already installed R€placement ol existing Combi boiler + Space requirements Minimal space available (instsllation in alcovel o Adequate sp8ce available {boiler toom)+ 10 Domestic Hot Water Production via fnstantaneous DHW Plate Heat Exchanger (Model WBz 6'24C1 DHW Production This lranslatas into immediate availability of domestic hot water at any requlred temoeratute level. The Vitod€ns 2OO Combi boiler is equipped with an electronically controlled instantaneous DHW plat€ h€at exchange.. Tochnical Data DHw Plals Hoat Exchanger Se€ pag€ 5 in this manual for technical data. 149 140 131 The comfort control ensures that the instantaneous DHW plate heat exchanget is kept consistently at tha required temoerature. (D 3122 (, o ErrT 5104o Io95 The diagram on thB lett illustrates how the OHW output temp€rature chang€s in relation to the draw ,8te at the tap. The DHW draw rate is restricled by m€ans ol a flow limiter to 2.1 GPM/8 ltrs per min D at a t€mperature ot 128 'Fls3 'C. lf more water is required, domestic cold water is added, resulting in a lower DHW output IemDerarure. In the example to the left, demonstratang the change in DHW output temperature based on th€ addition ol domestic cold water, a domestic cold water input temperature of 50'F/ l ooC is assumed. 1.6 1.8 2.1 2.4 2.6 Draw rate at tap (mixed water) DHW output t€mperature at the Vitodens 2OO boiler DHW/DCW mixing zone DHW output temperature at the mixing valve Restriction by tlow limiter 3.4 3.7 cpr,t G (B (q) Nt F. DHW Production Domestic Hot Water Production via DHW Storage Tank vitod6ns 2(X) gas-tired boiler up to model WB2 8-32 These boilsrs can be used in conjunction with tho DHW storage tanks otf€red by Viessmann. Se€ Vitodens 200 Svstem Design Guidolines for DHW sizing. All Viessmann DHW storage tanks sold in North America aro available in "VitosilvBr" finish only. DHW Storage Tank Connection With installation littings and builtjn circulsting pump for DHW production {via 3-way solenoid valvB) Legend OR DHW Return DS DHW Supply HR Hoating Return HS Hesting supply IMPORTANT An adoqualoly siz€d pr€charg€d expansion tank must be us€d, See Installation Examplas tor d€tails. Vitodem 2OO gas-fiied boiler model WB2 | | 44 and up Thes€ boilars can be used in conjunction with ths DHW storage tanks offered by Viessmann. All Vi€ssmann DHW storage tanks sold in North AmBrica ar€ available in "Vitosilver" Jinish onlv. DHW Storag8 Tank Connection With installation fittings and external circulsting pump for DHW production (optional 6quipm€nt) HS HR L4L-l DS DR = - l-. F |r) 't2 Wall Mounting Information (up to model WB2 8-321 Requirsd acc6$orle3 tor installation wlthout DHW storago t8r* Morntlng bracket c,/w mounting bolts ard fittings lllustration: Connoction ot gas-fired wallflounted Combi boilel Additional l€quiroment3 whon connocting a DHW srorage tank E E ra, Fot BRS DR/DCW R GC DS/DHW ttb Only for Combi hoating boiler DCw Domestic Cold Wator %" DHW Domestic Hot Watsr %" Only for standard h€ating boiler DR DHW R€turn %" DS DHW Supply %" Wall Mounting Mounting bracket Vitod€ns 2OO instsllation location BD Legerd BD Boilar Drain %"BR Boilar Return %" BS Boilar Supply %" FFL Finish€d Floor Level GC Gas Connection %" (gas slxjtotf valve is fiold supplied) A B o,l F. F.(o (, \ Wall Mounting Wall Mounting Information Vitod€ns Tho Vitodens 200 comes with a t8mplato, which allows you to easily mark tha location of th€ scrsws tor the mounting brackat and the location ol tre flue gss pipe on ths wall. 200 (modef WBz 11-44 and upl Tho connection to t]€ h€ating ckcuits (comsctlon fittings 6re suppliod in th€ Installation Fittings packago supdi€d with the boil€r) must b€ m6de on sit€. A B€ferenco polnt top odge VitodBns B Mounting bracket C Vitod8ns 200 mounting t€mplat€ 'I Racommendation Dlmenllons a = 23.6'1600 mm b = 3.2'182 mm c = 16"/407 mm d = O.7"/18 mm e = 29"/740 mm| = 78"/1975 mm o 6lF' F @ to Electrical Connection Electrical Connection Pow6r Supply The Vitodens 200 is shipp€d with a Power Module (up to mod€l WBz 8-32) or with 8 Power/Rrmp Module (model WB2 1 144 and upl. Both modules require a 120 VAC power supply from a wsll receptacle. The modules contain a 120/230 VAC step{p transtormor to power the Vitod€ns 2OO with 230 VAC. Rator to the Installation Inst uctions shipp€d with the modul€s for wiriqg dotails. Fowel Supply Conn€ctlon ot Acc€s3orios The pow€r supply connection of accessoriss can b6 mada directly at th6 boilor control. Th€ connaction is activatod and deactivat€d with th6 systom on/oft switch. The Dekamatik-HK1 control, ths mixing vslv€ extsnsion kit and the Solartrol control requiro I soparate 120 VAC powor supply trom the wall rsceptacl6. 2-wire cabling roquired for: r outd@r tompgrsture s€nsor I Vitotronic OsO/Dekamatik+lK 1 r acc€ssory kit for hsating circuit with mixing valve ! rsmote switchirE ot op€rating mode r remote disabls I alarm outDut r wallflount bas€ 3-wire cabling requir€d for: . r€mot€ control RS/WS r circulating pump ; <t F F.(D 15 Control for Weather-Responsive Operation Control for Weather-Responsive Operation Buih into th€ Vitodens 200 boiler : r Comtortrol menudriven paogramming unat Constructional Design and Functions Modular Structure Th€ control consists ol s programming unit' The control unit contains: Svstem on/of I switch. override/emission test switch, comfort switch (operational only on Combi hesting boiler), fixed high limit, adjustable high limit, digital display, micro{omput€r, adjustment options for switching times, Jor t€mperatur€s during normal and reduced op€ration, domestic hot wat€r tomperature, adjustm€nt options Jor hoating curves, temp€raturB scanning options, builtin diagnostic system and fuses. Boil€l-spscific Functions Tl'€ cortrol rnit adiusts tfE b(iler water temp€rsture (= st,pdy Gmporatur€ of a dir€ctcorn€cted h€atirg circdt 8rd/or a heatirE circuit with rrixirg valve in conjurEtixl with ttB exterBls.r kit for a fEatir€ circdt with mixirg valve) automaticalv 8rd on a corninrus basis to irdivlfual cutdoor temp€ratures. Th€ cmtrd has a DHw t€mperaturo corfioller wili DHW priotity switchr€ (tEatir€ cilcuit prmp off). Technical Dsta Rated supply voltag€: Rated trequency: Rated curr€nt: Max. ambi€nt temp6rature ! at op€ratbn: 120 VAC 60 Hz 124 32 to 1O4 "FOto 40 oC For use in your living area or boil€r rooms (with stardard ambient conditions) . wh6n storirE or transporting: -4 to + 149 'F -20 to +65 "C r Digitsl timer with day and week leature and lour programmabl€ activation periods per day for r€duced op€ration, activation ot DHW production or activation ol DHW circulating pump Setting adiustable high limit (space heating): 180 'F/82 'C Setting adjustable high limit (DHW production): 108 to 183 'F 42 to 84'c Setting fixed figh limit:210 0Fl99 0C (not adjustable) Adjustmgnt range of DHW setpoint tampefaure: r with Comlortrol programming unit: Adiustment range heating curves r Heating curve sloper Heating curve shift: r Freeze{p protection of entire heating syslem r Int€grated diagnostic system I Integrated DHW tank temperature control Timer of hogramming Unit lcontinu€dl Time, day and standard switching times are factory preset (individually programmable), up to four switching times selectable pe] day. Shortest switching interval: 10 minutes Pow€r reserve: 5 years Heating Programs The ireeze-up protection function'l is active in all operating modes. The Jollowing heating programs can be selected with the oparating mode selector switch: With Comfortrol programming unit . Continuous standby. DHW production only r Normal operation/reduc€d operation or normal op€ration/standby '' See -Freezetp Protection Function" below. Froeze.up Plotection Function The ireeze{p protection function is I switched on when tho outdoor temperature drops below aPprox. 34 0F/1 0C. When freeze{p protection has been activated, the h€atir€ circuit pump is aclivated and th€ boiler water is kept at a minimum temperature of aPProx. 68 0 F/20 0C. ! deactivatsd when the outdoor temperature exceeds approx. 37 oFl3 "C. Summer Operation Heating program "w" The burner is only activated upon a call for domsstic hot water from the DHW storage tank (controlled by DHW tank temperature sensorl. 50 to 140 "F 10 to 60 'C O.2 to 3.5 10 to 91 oF -'12 to +33 oC Comfortrol Programming Urit r llluminated display with 8 text lines r Menuiriven user guidance ! All settings, main codings and fault messages shown in Plain text r Holiday program I Party button for switchir€ to "normal operation" whenever toquired r Energy savings button lor lowering the desired room temp€rature by approx. 3.6 oFl2 oC in normal operation. Tho programming unit can be used as a remote control (wallfiount base must be ordered separately). Timer of Programming Unit Digital timer with day and week l€ature, calendar and automatic rss€tting to daylight savings time. c ci l-- T\(o |r) to Control for Weather-Responsive Operation Ouidoor Temperature SengolHeating Curve Adiustment (slope and shiftl The control unit regulstss the boiler water temperaturs (= supply t€mperatu,e of heating circuit without mixing vslve) and the supply temperature ol the heating circuit with mixing valve (in coniunction with the extension kit fot a hesting circuit with mixirE valve) according to the outdoor temp€ratura. Th€ supply temp€raturo thst is requared to achieve a given room temperature deperds on thB heating syst8m 8nd the tharmal insulation of the building that is being h6atod. The sdjustment of the two heating curves is us6d to match th8 boiler water temperature and the supply temperatur€ to these conditions. Heating curvss: Boiler Temperaturg Sensor The boiler temoerature sensor is connected at the control unit for weather{esponsive oDeration and is built into the boiler. Max. ambient temperature r at operation: 32 to 266 "F 0 to 130'C . when storing or transporting: -4 to + 158 'F -2O to +7o "C Symbol lZ 2.6 2.4 Sensor location: r North or northwest wall ol building ! 6.6 to 8.2 lt.l2 to 2.5 m above ground or, in cas6 of I multi-storey building approx. halfway up th€ second Jloor Electrical connection:t 2-wire cable, max. cable length 1 15 ft./ 35 m with a wira size ot min. AWG 1 6 copp€r r Cable to the outdoor sensor must not be be laid near line voltage wiring 1120/240 Vl Max. ambient t€mperature at operation, when storing or transporting: -40 to + 158 "F -4O to + 70 'C DHW Tank T€mperature Sensor Part No. 7134 239 Supplied with: r installation fittings for horizontal DHW storago tanks 14210 12O USG/I60 to 45O Itr) (DHW tsnk must be order€d separately at tim€ of order)I installation littings lor vertical DHW storaga tanks (42 to 120 USG/160 to 450 Itr)(DHW tank must be ord€ted separately at time of order) t DHW production kit for Vitodsns 2oo Cable length approx. 13 ft./3.75 m, ready for plugin Max. ambi€nt temp€rature r at operation: 32 to 194 'F0to 90"C . when storing or transportrng: -4 to + 158 'F -2O to + 70 oC r{l o, g o o I I oF oc 230 110 212 100 194 90 176 80 't58 70 140 60 122 50 104 40 r,+-<orltr6 1.0 - 2.o -'T I't.8 .,\(c) .4 t-o JU Low temperature heating system, e.g. radiant floor heating Medium temperalure heating system, e.g. cast iron radiation, staple-up radiant floor heating @ High temperature heating system, e.g. fintube radiation, tan coils The boilar wat€r t€mDerature is limited upwards by tho lixsd high limit and the temperaturo sot for the eletronic high limit. The supply t€mper€ture cannot ris€ above ths boiler watsr temp€rature. -s -rb -rs -zo oc z3 14 s -+ oF Outdoor temperature G € o Nl-. F(o rl) Control for Weather-Responsive Operation Accessories Control for Weather-Responsive Operation Accessodes E t Mixing Valve Actuator Accessory Kit, Part No. 71 33 392 Mixing valve actuator The mixirE valve actuator is mounted directly on the Vi€ssmann 7+ to 2Yz" mixing valve. The mixing valve actuato. is a motordrivsn control unit. The rotational direction is roversibls, The mixing valvo actuator comes with a plug-in connector tor a heating circuit pump, supply temperature s€nsor lstrap{n sensor with 19 lt./5 m conn€ctir€ cable), power supply connecting cable ('l O ft./3 m) ard connecting cable tor KMgUS (1O {t./3 m). Supply Temps;aluie Sensor (strap-on s6nsor, included wath valve actuator accessorv kat). Part No. 71 33 895 mrxrng Installed with a strapping band. Cable length 1 9 ft./5 m, ready for plug-in. Max. ambient temporature r at operation: 32 to 212 "F 0tolOOoC r when storing or transporting: wall-lvlount Base with Blank Cover, Part No. 7133 385 (for us6 when the programming unit of the control is used as remote controll All functions oJ the programming unit can b€ used. WS Junction: Unit can be mountec anywhere in the building. RS function: The remote control is mount€d on an inside wall of the main living ar€a opposit€ radiators, not in shelves. alcoves or next to doors or sources of heat (e.9. in direct sunlight, next to a fireplace, TV set. etc.). Electrical conn€ction: .2-wire cable, max. cable length 98 {t./ 30 m with a wir€ size of min. AWG 16 copper r Cable to the outdoor sensor must not be be laid near line voltage wiring 1120t240 vl Max. ambient temperature . at operation: 32 to 104 oF Oto 40"C r whon storing or transporting: -4 to + 149 'F -2O to + 70'C Rated voltage: Rated fr€quency: Rated current: 1 20 VAC 60 Hz 4(2lA Power consumption; 4 w Max. ambient temo€rature r at op€ration: . when storing or transPorting: Vress.nam 2-tvlrs BI,JS Expondq| Modle, Part No. 7133 393 lor connecting a Vitotronic 050 or a Dekamatik +lK heating circuit control, a Vitocom 20O, a Vitocom 3OO or a Solartrol control. Comprises one circuit board. S€tting rang8: 86 to 212'F 30 to 1O0 'C Operating diflerential: I K 32 to 1O4 'F O to 40'C -4 to + 149 oF -20 to +65 "C -4 to + 149 oF -20 to +65'C Relay output for heating circuit pump: 4(2) A, 1 20 VAC Actuator torque: Timoof90e+: 3Nm 2 minut6s c c{ F. t Remoto Control WS Psrt No. 7133 380 Control f or Weather-Responsive Operation Acces so ries R€mots Contiol RS Part No. 7133 381 Boilsr Tempsrature lndication Unit, Psrt No. 7133 384 Must be insorted inb t|e contrd urit for weatfEr{€spo(Give op€ration when ttE p(ograarmirg urit of trE cortrol urit is usod as remots cmtd. Bciler watsr temperat-{e ard fadt rnessages are disdayed. Tomooralure Sonsor for Low{-oss Headsr, Part No. 7 l34 240 Supply tomperature sensor for ths common supply in applications with 8lowloss header. Installed with a strsppirE band. Cable length approx. 12 tt.l3-75 m, rcady for plugin. Max. ambient temoerature {2 a =\w. r at operation: r when storing or transportir€: 32 to 1O4 'FOto 90'c -4 to + 149 'F -20 to +70 "C ! at oporation: r when storing or transporting: 32 to 1O4 "F O to 40'c -4 to + 149 oF -20 to + 65'C The remote control unit is used for setting the desired temp€ratures tor normal op€ration (daytime temperature) and reduc€d operation (night setback temperature) ot one heating circuit from any chosen room in the building. Only one remote control unit can be connocted. lf I heating circuit with mixing valve is installed, the romots control controls the heating circuit with mixing vatve. Electrical connection: r 3-wire cado (without "greeruvellow" wira), max. cabb lengtt 98 ft.Ro m with a wire siz€ ot min. AWG 16 copper . Cable to tho WS control sansor must not be laid near line voltage wiring (120t240 Vl Max. ambient temp€rature The rgmote control unit is used lor setting the desired temperatures lor normal operation (daytime temperature) and reduced operation (night setback temperature) of one heating circuit from the main living area. The builtin room temperature sensor measures ths room tomperature and initiates any n€c€ssary correction of the supply temperatur€. Only one r€mote control unit can be connected. lf a heatirlg circuit with mixing valvs is install€d, the remote conttol unit controls the heating circuit with mixing valve. The r€mot€ control unit is mounted on an inside wall ot the main living area opposite radiators. but not in shelves, alcoves or immediately next to doors or sources of heat (e.9. in direct sunlight, next to a fireplace, TV set €tc-). El€ctrical connection: t 3.wie catle (wftfnn "greetuVellow" warel, max. cado l€rg0t 98 tt.l30 m with a wire siz€ ol min, AwG 16 copper r Cable to the RS control sensor must not b€ laid neaf line voltage wiring 1120t240 vl Nolo on Room Temperatute Dependent Control (RS Functionl with Eemote Controls 8€caus€ ol the "inertia" oJ underfloor heating systems, the RS function must not be used for an und€rfloor hesting circuit. Max, smbient temoerature Setting range for room temp€rature setpornl r Selector knob " s ": 57 to 79'F 14 to 26'C r Selector knob "m": 45 to 73'F 7to23"c Desired room temperature when selector switch is sot to "9": 37 to 41 "F 3 to 5'C r at operation: r when storing or transporting: 32 to 104 'F0to 40"C -4 to + 149 'F -2O to +65'C a.t F. r..ro rJ) Setting range for room t0mp€ratur€ satpornt r Sslector knob " s "; 57 to 79 "F 14 to 26 "Cr Selector knob "m": 45 to 73'F 7to23"C Desirsd room t€m- perature when selector switch is set to "9": 37 to 41 'F3to 5"C 19 Control for Weather-Responsive Operation/Vitodens 200 Accesso ries {2 Room Tempotature Sensor, Part No. 7133 379 Seoarat€ room t€mosrature s€nsor used in addition to tha RS remote control Jor applications whsr€ the RS ramote control unit canmt bo positioned in tho main living room or in 8 suitabl€ location lor t€mp€raturs measurament/sstting purposes, Ths room tsmo€rature sensor is mounted on an insido wall of th9 main living room opposite radistors, but not in shelves, alcovos or immediat€ly naxt to doots or sources ot heat (6.9. in direct sunlight, next to a firsplsce, Tv sel atc.). Tho room temDeraturo sensor is connected to the RS r8mote control unit- Electricsl conn€ctaon: r 2-wir6 cable with a wire size of min- AwG 16 copper r Ths cablo length b€tween the control unit, romots control unit and toom temperature s€nsor must not excssd 98 tt./3o m. I Cabl€ to the outdoor sensor must not be laid n€sr line voltage wiring 1120t240 vt Max. ambiant t€mperatur€ r 8t operstion: 32 to 1O4'F Oto 40'C t when storing or transPorting: Accessories lor Vitodens 2O0 Neut.alization Unit for SingleSoilel Applications with neutralizing granulate for vitodons 200 up to model WB2 832 Part No. 7134 231 for Vitodens 2oo mod6l WB2 1 1 -44 €nd up Part No. 7134 232 Neutralizaiion Pellats .4.4 x 2.9 lbs./2 x 1 .3 kg) Part No. 9524 670 For roiill or replacement purposes Cosmetic Piping Covet lor Installation Fiftings to cover water ard gas fittir€s anc ptrr€, Ior VitoderB 2OO up to rnodel WB2 832 Part No. 7339 571 Low{oss Header Part No. 7134 230 (max. flow rate 4 m3/h / 17.6 GPM) Part No. 7'l 34 244 (max. flow rate I m3/h / 35.2 GPM) When used in conjunction with the Vitodons 2OO boiler, the low-loss header scts as hydraulic br6ak, dscoupling boiler and svst€m circuits trom each other. It is recommend€d to use the low{oss header in spplications in which ths total system flow rate exc6€ds the maximum boiler llow rate. Viessmann strongly r€commends th€ use of a low-loss header in cas€s wh€rs the syst€m head 8nd llow ratss ar€ unknown. The temDerature sensor connection located at the top of the low-loss header ensures low return temDeratures to the Vitodens 2OO boiler at all times. increasing oDerational efficiency. In addition, th€ low]oss haader helps eliminate air and debris f.om th6 heating system. See Installation Instructions ot low-loss header for details. -4 to + 149 "F -2O to +65'C ExpaBion Board, Part No. 7134 2O9, 7134 211 With th6 expansion board the lollowing capabiliti6s aro added: r Connection ol an additional h€ating circuit pump (only for modsls up to wB2 832) I Connection ol a dry contact to opsrate an sxternal alarm with lhe following ratings: 24t250V,5A C'J r.. F. @ 20 Standard Equipment Standard Equipment Vitodens 200 The Vitodens 200 gss-fired condensing Wall mountlng componentry boiler with Inox-lladial heat exchanger The tollowing wsll mounting compononts surlacos, modulating Matrixaompact gas are suppliad with the Vitodans 20O boiler: burn€r for natural gas and liquid propana. I Mounting brscket (com€s preinstall€d tor aquatlate with plugin connection system modols up to WB2 8€2) c/w I Mounting bolts r pr9asurg gage and KMSUS varisble spead r Instsllation fittings pump (tor WB2 6-24c, 6-24 and 8-32 onlyl r Scr€ws for mounting brackst on ! instsllstion fittings with 30 psig pr€ssure - wood studs (2" x 4") relief valvo and 8ir vent - mstal studs r Comlortrol boilBr control unit with outdoor - brick/concret€ wall temperature sonsor, powsr modul€ (up to mod€l WB2 832) or power/pump modul€ (mod€l WB2 1 144 and up) - Th6 boiler comes fully piped and prewired, rBady tor plug.in. - Th€ Vitodons 2OO Combi boilsr is squipped with 8n integrated stainl€ss steel plate heat exchangor tot instantaneous DHW heating. - Venting material is to be supdiod by Vlaalmann only. Venling installallon mutt Inchdo Vio$mann protociiys scrson! - Enclosur€ finish: black ste€|, powdor{oated white - Tho Vitodsns 2OO comes rsady for use with natural gas and can be tuel corwerted fot operation with liquid propang. q 6lF F@ |l) Installation ExamPles Installation Examples lmportantl ThL lollowing examples depict possiblo piping layouts ot tha vitod€m 2OO boilsr oquippod with vlessmann Systom Technology' For boiler and lank comHnations, please irctall only leasible comblnations listed In the via$mann Prico Lisl. Pleas€ nol€ that tho ex6mplo3 below are simplified conceptual drawings only! PiFing ard nocessary compononlry must bo field verilied' A low water cut€ft (LWCOI must bs installed whole tequited by local codes' Ropsr installatlon ard functionaliry in ths field is the responsitility of th€ healing contractor. Vitodem 200 (model WB2 6-24C1 with a direct-connected heating circuit o tltl--T-- I AV Air vent DCW Domestic cold watsr DHW Domestic hot water PRV 1 Pressure relisf vslve (3O psig) PRV 2 Pressure relief valve (150 psig) WSE Water soft€ning equipment/lilter G Vitodens 2OO gas'tired Combi boile r G Heatinq circuit O RemotJ control Jor Comfortrol programmlng unll O Outdoor temperature sensor oJ control unit for weather-r€sponsiv€ operation Lll €, Precharged expansion tank GZ Precharged expansion tank (r€quired where backtlow Ptev€nter is install€d; chsck local plumbing codes ard requarements). Expansion tank pressure rating must be greatsr than 150 Psig and suitsble for Potsbl€ watel applications. Upon a call for OHW, th€ built'in diverting solenoid valv€ is energized. Tho boiler hot water is diverted to the DHw loop 8t maximum pump rotational spe€d (no variable speed pump operation during DHW oroduction). Onc€ th€ DHw instantsneous plate heat exchanger is satisfiad, the builtin diverting solenoid valv€ is d8€nergized and heating operation rssumes. The builtjn plat€ hsal sxchang€r is equipped with two independent tomperalure safety tealulss, ons limit tamp€ratule switch on ths hoaling boiloa side and one ternp. control serrsor on lhe DHW side. F.{ F (t 22 lnstallation Examoles Vitodens 2OO (up to model WB2 8-231 with one direct-connected heating circuit and one DHW storage tank, heating circuit with a mixing valve Installation of diff6lsnt hoating circuils... r rsdiator heating circuit (high temperature circuit) r urd€rfloor heating circuit with 3-way mixing valv€ (low temperature circuit) r DHw production ...with th€ following flow corditions 1 . The watsr flow rate (output) of ths radistor heating circuit is at lBast 30% grgater than that of the underJloor hoating clrcuit. 2. The total flow rate of the two heating circuits is less than the maximum possible wat€r flow rat€ of the Vitodens 200 (soe following tabl€). The use of a low-loss hsader is strongly recommended it the m€ximum water {low rate in th€ application concsrn€d exceeds the values shown in th€ tabls above, or if the system flow rates are unknown. The lowioss header is availabl€ as accessory part. See following pag€s for installation €xamol€s with € low-loss header. AV Air vent PRV Pressure reliet valve TPV TempBratur€ and pressure relief valve Vitodens 2OO gas-lired condensing boiler with Comfortrol programming unit lor weather{esponsive operation Outdoor temperature sensor Ll_J R€mot€ conirol for Comfortrol programming unit Underfloor heating circuit Radiator heating circuit Heating circuit pump (field supplie-!q MixirE vslve tempsrature sensor L4 Extension kit for a heating circuit with mixing valve Domestic hot water storage tank DHW tank temperature sensor l5l Exoansion tank Th€ 3-way mixirE valve. builtjn to achieve the low temperature level ol the underfloor heating circuit, is controlled by an extension kit tor a heating circuit with mixing valv6. Tho circulation pump built into the Vitodens 200 boilsr supplies the radiator hesting circuit. The underfloor heating circuit is suppli6d by a circulation pump installed on site which is controlled by the extension kit, Upon a call for DHW, the builtjn div€rting solenoid valve is energized. The boilBr hot water is diverted to the DHW loop at maximum pump rotational speed (no variable speed pump operation during DHW production). Once the DHW tank is satistied, the builtjn diverting solenoid valve is de+nergized 8nd heating operation resumes. G G (9 a(E) g. (G)6 CD G)o C\{ F F Max. flow rala (GPM/ltr/hl 23 Installation Examples Vitodens 2O0 lup to model WB2 8-32) with one heating circuit with mixing valve and one heating circuit without mixing valve and DHW storage tank, low-loss header AV Air vent PRV Pr€ssure r€liet valve TPV Temperatur€ 8nd pressure r8lief valve G G6 t6)t5HI C) G)o G)o Vitodens 2OO gas-fired condensing boiler with Comtortrol programming unit for weather{esponsive ooeration Outdoor t€mperature sensor E Remote control for ComJortrol programming unit Undertloor h€ating circuit Radiator heating citcuit Heating circuit pumps (field supplied) Mixing vslve temperature sensor L4 Extension kit tor a hoating circuit with mixing valve Domestic hot water storag8 tank DHW tank t€mperature sensor E Expansion tank Low-{oss header Temp€rlllure sensor lor low-{oss h€ader Lll Installation ol diftsrsnt heating circuits... . radiator hBating circuit (high tomperature circuit) I und€rfloor hoating circuit with 3-way mixing valve (low temparature cifcuit) r DHW production ...with the tollowlng flow conditiong 1 , The totsl flow rate ol the two heating circuits is greator than th€ maximum oossible watar flow rate of th€ vitodens 2o0. ThB use of a lowloss h€ader is therelore r6commenoeo. The lowloss header is available as accessory p8rr. The 3-way mixing valve, hJiltjn to achieve the low temp€raturg lsvel of the underfloor heating circuit, is controlled by an €xtension kit for I hoating circuit with mixing valve. Th€ circulation pump built into the Vitodens 2OO boiler supplies the heating circuit up to th€ lowloss headar. The radiator heating circuit is supplied by a circulation pump installed on site. An 6xpansion board (optional) must b€ ordered trom Vi€ssmann to control this pump. Th6 urd€rtloor heating circuit is supplied by a circulation pump installed on site which is controlled bv the extension kit. Upon a call for DHW, the built jn diverting solenoid valve is energized. Th€ boiler hot water is diverted to the DHW loop at maximum pump rotational speed (no variable speed pump operation during DHW production). Onca th€ DHW tank is satistied, the built-in diverting solenoid valve is d€-energiz€d and heating operation resumes. c,'J F. F. 24 Installation Examples Vitodens 2OO (up to model WB2 A42l with DHWtwo heating circuits with a mixing valve storage tank and AV Air v€nt PRV Pressure rali€f valve TPV Temp€ratute and pressure r€liel vatve @ vitodens 2OO gas-fired condensrng boiler with Comlortrol programming unit Ior w€ather-resoonsive oDeration Q outaoor temperature sensor I(9 Remote control lor Comfortrol ^ progtamming unit !92 UnCerfloor haating circuit I Radiator heating circuitq Heating circuit pump (field supptied)(p Mixing valve tamperature sensor @(D Ext€nsion kit tor I hoating circurt with mixinq valve(l) Vitotronic -OsOi Dekamatik -H K I control with communication moduleG) OHw storage tank(L) DHw tank tomp€ratu.e sensorpO) Exoansion tank(D Low-loss headerO Temperature sensor for low-loss header f5lO vitotroDoo ramote control Installation of ditferent hoating circuits.,, r rsdiator heating circuil I underfloor h€ating circuit with 3-way mixing valv€ (low temp€ratura circuit)r DHW production ...with the lollowing flow conditiom 1 . The total flow rat€ ot tho two h€ating circuits is greater than tha maximum possible flow rste ot th€ Vitodans 2OO.The use of a low{oss h€ader is therefore recommended. The low-loss header is available as accessory part. The 3-way mixing valve, builtjn to achiave the low tempersturs l6vel of the underfloor heating circuit, is controlled by an €xrenston kit for a heating circuit with mixing valve, The circulation pump built into the Vitodens 2OO boiler supplios the heating circuit up to th€ low{oss header. The underfloor and rsdiator heating circuits aro supplied by circulation pumps install€d on site which ara controlled bv the extension kit or the Vitotronic O5O/ Dokamatik-HK1 control. lf more than two heating circuits wrth mixing valves are to b€ connected, they can bs controlled by the Vitocontrol. Contact your local Viessmann Technical Sales Representative tor details. Upon a call tor DHW, th€ builtjn diverting solenoid valve is 6n6rgized. The boiler hot water is divert€d to the DHW looD at maxamum pump rotational speed (no variabl6 speed pump op6fation during DHW production). Once the DHW tank is satislied, the builtjn divsrting solenoid valve is de€nergized and hBating operation rosumes. - (\ Fv lt.(o IJ' za lnstallation Examples Vitodens 200 tup to model WB2 8-321 with direct-connected one heating circuit with system separation Insrallation of ditferent hoadng circuits.... radiator heating circuit (high t€mperature circuitl r und€rtloor h€sting circuit with 3-way mixing valv€ llow temperatufo circuit)r DHW oroduction ...with the following flow conditions 1 . The flow rato (output) of th6 radiator heating circuit is at least 30% graater than that ot th€ underfloor hsating circuit. 2. The total flow rate of the two heating circuits is less than tha maximum Dossible water flow rats of tho Vitodens 20O boiler. heating circuit and The use of a low{oss head€r is strongly recommended if the maximum w8ter f low rate in the application concerned gxceeds th€ vslues shown in ths prec€dir€ table. or iJ th€ systBm flow rates are unknown. The low-loss h6ader is available as accessory p€rt. See following pag€s for installation examples with a lowloss head€r, The 3-way mixing valve, built-in to schieve the low t€mp€rature lev€l of ths underflool heating circuit, is controll€d by an €xtension kit Jor a heating circuit with mixing valve. Th€ circulation pump built into the Vitodens 2OO boiler supplies th€ radistor heating circuit and the platg heat sxchanger tor system separ€tion. Ths underfloor heating circuit is supplied by I circulation pump installed on site which is controlled bv the extension kit. Upon a call for DHW. th€ buitt.in div€rting solenoid valve is an€rgized. Th€ boilar hot water is diverted to the DHW looo at maximum pump rotationsl sp€ed (no variablo speed pump op6rstion during DHW production). Onca th€ DHW tsnk is satisfied, the builtin diverting sol€noid valvB is de€nergizsd and heating oporation resumes. AV Air vent PRV Pressure relief valv€ TPV Temperature and pressure roli€f valve Vitodens 2O0 9as-firsd condensing boiler with Comfortrol programming unit tor weather{esponsivs operation Outdoor t€mp€rsture sensor I R€mote control Undorfloor heating circuit Radiator h8ating circuit Plate heat exchang€r for system soparatron Heating circuit pump (field supptied) Mixing valve temperaiure sensor @ Extension kit lor h€ating circuit with mixing vslvs DHW storage tsnk DHW tank temperaturs sensor E] Exoansion tank IMPORTANT The pressure drop (3econdary circuit) ot the plate heat exchanger(! must be l€ss tharvequal to lS ) the pr€ssufa drop of the 3-way mixing valve. This mual be tak€n inlo account when sizing rhe date heat €xchanger. G G (c) (D) (E) € G) (H) dl G)oo ct F. F 26 Vitodens 2OO lmodel one direct-connected WBz 11-44 and upl with heating circuit DHW storage tank and Installation Examples AV Air vent PRV Pressura r€lief valve TPV Tempsrature and pressure relief vatva Vitod6ns 200 gas-firod condensing boiler with Comtortrol ptogramming unit for w€ather{esponsive ooerataon Outdoor l€mperatur€ sensor of control unit for waathsr{esponsive oporation LIJ Remots control tor Comtortrol programming unit Heating circuit Heating circuit pump (field supplied) DHW circulating pump (field supplied) DHW storage tank DHW tank temp€ratura sensor LII Exoansion tank Pl€ase note! The use of a low{oss header is recommend€d il the system water flow rate is le33 thsn 1.3 GPM i 300 ltr/h or mor€ than | 5.4 GPM / 35OO ltr/h. The lowloss header is available as acc€ssory pan. IMPORTANT DHW circ.|rlating pump e must pump rhto the Vitodons 200 boiler (as illustratedl. 1 I i I I I I I II I I I I I IJ G G / \\\r' (o) a5 (G) (H) d (\{r\ F.(o Installation Examples Vitodens 2OO (model WB2 11-44 and upl with DHW storage tank, one heating circuit with mixing valve and system separation Please note! The us€ ot 8 low.{oss ho6der is r€commonded if th€ system water tlow rate is l€$ thsn 1 .3 GPM / 30O ltr/h or more than 15.4 GPM / 350O ltr/h. Th€ low.loss h€8d€r is available as accossory part. Pl€ase notel System separation is roquir€d of undertloor heating systems employing non€xygen diffusion barrier tubing. All components on the socondary side ol the hest exchanger must be made ol corrosion{esistant mat6rials. AV Air vsnt PRV Pressure reliet valve TPV Tamp€rsture and pressure relief valve Vitodens 2OO gas-fir€d condensing boilar with Comfortrol programming unit lor weather{esponsive operation Outdoor t€mperature sensor of control unit for weathor{esoonsive operation E R€mote control Underfloor hBating circuit Mixing valve temperature sansor @ Heating circuit pump (field supplied) H6ating circuit pump (li€ld supplied), located upstream of h€at oxchanger Rate haat exchang€r for systom ssparation Extension kit tor heating circuit with mixing v8lve DHW circulating pump (field supplied) DHW storage tank DHW tank temperature sensor LII Exoansion tank IMPORTANT DHW circulalion pump (l) must pump rnto the Vitodens 2OO bdler (as illustrared)- 6 G o (D) (E) G1 6' @ @ o G)o 6) c\ l-.{ l.\ @ I Vitodans 2OO {model WB2 11-44 and up) with DHW storage tank, low-loas header and one heating circuit with mixing valve Installation Examples AV Air vent PRV Prsssure reliet valve TPV Tsmperature and prossure rsli€f valve o (D) (G) d1 6'() G)o G) 6)oo G € Vitod€ns 20O gas-fired cond€nsing boiler with Comfortrol programming unit for wgather{esponsiv€ operation Outdoor t€mp€rature sensor of control unit for weather{esponsive operation E Remote control Primary pump (boiler circuit, field supplied) Underfloor hgating circuit Radiator h€sting circuii Mixir|g valv€ tomperature sensor pl Hsating circuit pump (tield supplied) Heating circuit pump (field supplied) Ext€nsion kit for heating circuit with mixing valve Lowloss head€r T€mperatura sansor for low.loss header E DHW circulating pump (f iold supplied) DHW storage tank DHW tank t6mp€rature sensor L:l Exoansion tank Hsdsg note! Th€ us€ of a low{oss h68der is recomm€ndBd it the wat€r tlow rats is l€ss than 1.3 GPM / 300 ltr/h or mor6 than 15.4 GPM / 350O ltr/h. The lowloss headsr is svailable as accsssory part. The radistor heating circuit is supplied by a circulstion pump (fiold supplied). An €xpansion board (ootional) must be ordered trom Viessmann to control this pump. The undarfloor heating circuit is supplied by a circulstion pump installed on site which is controllod by th€ extgnsion kit. Thg DHW circulation pump is fi6ld supplied. IMPORTANT rumps @ and @) must pump mto the Virodens 2OO boiler {as illGtratedl. (\ F. f.(o K' @ [___]o e Installation Examples Vitodens 200 lmodel WB2 11-441 with DHW storage tank, low-loss header and multiple heating circuits with a mixing valve AV Air vent PRV Pressure relief valve TPV Temperature and pressure ralief valve @ vitooens 200 gas-fired cond€nsrng boiler with Comtortrol programming unit for w6ath€r{esponsiv€ oporation and Viessmann 2-wirs BUS ext€nsion module G outdoor tomp€rsture sensor ot control unit for weather{esponsivo ^ operation Lll G) Primary pump (boiler circuit, ti6ld supplied) Vitocontrol't Mixing valve temperature sensor E Heating circuit pump (field suppliedl Extonsion kit for heating circuit with mixing valve H€ating circuit with mixing valv€ Extension kit for hsating circuit with mixing valve Temperature sensor for low-loss header LqJ Low-loss h€sdeI DHW circulating pump (field supplied)(D DHw tank temporature sensor @@ oxw storage tank O Expansion tank 'l contact your local Sales Reprcsentative for details. IMPORTANT Rrmps @ and 6) must pump ,itto the Vitodens 2OO boiler (as illuslratedl. E \1(E) (H) a6 (D oo N|.\ F. (, System Design Considerations Boiler location As a dir€ct-vent applianc€, the Vitodens 200 for room air temp€ratur€ independent oo8ration {seslad combustionl can be installed regardless of size and ventilatioo method of the room in which it is located. The Vitod€ns 2OO can be installed, for sxampls, in the main living area of a house. in mn-\renti18ted utility rooms, cupboards, closgts and alcovos with no clearance requir€d Jrom combustible materisls, as well as in attics with s direct outlet for the flue gasifr€sh air system. Follow all local and national codes. Flue gas system Viessmann PPS (Polypropylana) concentric tlug gas/fresh air systems lor room air temp€raturs ind€pend€nt op€ration ls68l€d combustion) and sidg wall v€nting aro tosted to ANZI 221 .13 - CSA 4.9 - 2000 standads and are certitied together with the Vitodens 2OO boiler as a constructional unit. For a more detail€d description of the direct vsnt system, plesse refor to the Vitodens 20O System D€sign Guidelines. Flue gas temperature protection FluB pipss used for the Vitodons 2oo are suitabl€ for max. tlue gas temperatures of up to 248 oF/l20 oC. No flu€ gas t€mperatura prot€ction is r€quir€d as the maximum p€rmissible flue gas tsmparatur€ is not gxcsedsd in any oporating condition or in the event ol maltunctioning. Low water cut-oft A low water cut-off may be required by local codes. lf boil€r is installed above the radiation level, a low water cut-off device of approved type must be installed in all instances. An approved type low water cut-off device must be provided by the heating contractor. Do not install an isolation valve between the boiler and the low water cut-off . System layout r The max. boilor water temoerature is limited to 167 oFl15 oC. To minimiz€ distribution losses, Viessmann recommends that the heating and domestic hot water systems b€ based on a maximum boi16r supply temperature of 158 oFl7O oC. r Due to the low r€turn temperatures required lor gas cond€nsing, no mixing valves must be incorporated in the h€ating circuit whenever possibl€. lf mixing valv€s are required, e.g. tor multi{ircuit systems or underlloor heating systems, only 3-way mixing valves must b€ used. Do not use 4-way miring valves with condensing boilers, Underfloor heating systems For underfloor heating systems Vi€ssmann r€commends th€ use ol plastic tubing with 8n oxygan diffusion barrie. in order to prevent the diffusion ol oxyg€n through tubirE. lf plastic tubir€ without an oxygen diffusion barrier is used in underfloor h€ating systems, Viessmann recommonds that such svstems be separated from the boiler with a h€at oxchang€r. Underfloor haating systems and heating circuits containing a very large volume ol water must be conr€cted to the boiler via a 3-way mixing valve; pl€asa refer to the applicable section in th€ Vitodens 200 System Design Guidelines. Condensate and condensate neutralization Please refer to ths Vitodens System D€sign Guidelines. Oxygen diffusion barrier underfloor tubing The boiler warranty do€s not cover leaks resulting from corrosion caused by the use ot underJloor plastic tubing without an oxygen diflusion barrier. Such systems must have the non€xygen diffusion barrier tubing seoarated from the boiler with a heat exchanger, Viessmann recommends the us€ ot underfloor plastic tubing with an oxygen diflusion barrier. System Design Considerations Water quality Treatment tor boilar foed water should be considered in areas ol known problems, such as wh€re a high mineral content and hardness exist. In areas where freezing might occur, an antifr€aza may be added to the system water to protect the system. Please adhero to the specitications given by the antifreeze manufacturer. Do not use automotiv€ silicat€ based antifreeze. Pl€ase obsefve that an antifreeze/watea mixtur€ may requir€ a backllow preventer within the automatic wat€r t6€d and influence components such as diaphragm expansion tanks, radiation, etc. A 40% antitreeze content will provid€ fr€eze-up protection to -l OoF / -23oC. Do not use antifreeze other than sp€cifically made tor hot water heating systems. Systam slso may contain components which might be negatively aftoct€d by antitr€62e. Check tot€l systom trequently when till€d with sntifreeze. Advise system op€rator/ultimate owner that system is lilled with a glycol mix. The heating contractor must provide a MSDS (Material Sslety Data Sheet) lor the antitreeze used to the system operator/ultimat€ owner. Wa rra nty Our warranty does not cover damages resulting trom the tollowing: - installation or service by unqualitied and unlicensed pgrsonngl - attempting to perform any repair work on the boiler oth€r than that mentioned in the boiler literature. - tampering with or attemptirq to readjust th€ factory settings of th€ - combination gas valve - combustion air op€ning ot the burner blower For detail€d warranty inlormation, pleasa read warrantv shset supplied with product. System design guidelines For lunher inlormation on system planning and system dosign guidelines, please reference the Vitodens 2OO System Design Guidelines. Nt.. t-(o 31 ; .:o -6 Es E€ Eg .eE 6E COOE o9 PX- Eg (, oE fo 3 C)o 6 o tt, o o €() o .o Vie$mann M.nufacturing Company lU,S.) Inc. 45 Access Road Warwick, Rhode lsland . 02886 . USA Tol. (4Ol) 732-0687 . Fax (401) 732-0590 www.vias8mann-ug,com . mail@viessmann-us.com s2 q Viessmann Manufactudng Company Inc. i 75O l\lcMurray Road S Waterloo, Ontario . N2V 2G5 . Canads + Tel. (519) 885-6300. Fax (519) 886-0887 D www.viessmann.ca.mail@viessmann.ca ; TOWN OF VAIL 75 S.FRONTAGEROAD vArL, co 81657 970479-2138 Qroo*rrENr oF coMMUNrrY o".Torrr*, NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M02-0196 VP'""a ){ \\ Job Address: 2039 SUNBURST DR VAIL Status . . . : ISSUED Location.....: 2039 SLINBURST DR Applied . . : 09/17/2002 Parcel No...: 2101 10201009 Issued . . : 09127/2002 ProjectNo: afi\ol. aj ]; Expires. .: 0312612003 owNER PIERCE, MARITTA O9/L7/2OO2 Phone: PO BOX 1123 VAIIJ CO 816s 8 I-'icense : COr{TRACTOR SWEDE'S METAL FAB 09/L7/2002 Phone: 970-331--3335 P.O. BOX 801 MTNTURN, CO 81545 License : 239 -Nl APPLTCANT SWEDE'S METAL FAB O9/L7/2002 Phone: 970-331--3335 P.O. BOX 801 MTIflFURN, CO 8L645 License : 239-M Desciption: VENTING OF 4 BATH FANS,VENTING OF KITCHEN RANGE HOOD Valuation: S600.00 Fireplac€ Infomation: Restrict€d: Y # ofcas Appliances: 0 # ofcas Logs: 0 # of Wood Pellet: 0 +tt +l t 'i t * * ** * *'t r 't ** 'l ** * **:* l * **'t * *,* Mechanical-> S2o. o0 Resluannt Plan Review-> 90.00 Total Calculaled Fees--> S28 - 00 Plan Check--> 95.00 DRB Fee-----------> S0.00 Additional Fees-------> 90.00 Investigation-> $o - 00 TOTAL FEES------------> $28. oo Total Permit Fee-----'> $28 - 00 WillCall----> S3 - oo Payments--------------'> $28 - 00 BALAI{CE DUE-----> S0. 00 Item: 05100 BUILDING DEPARTMENT 09/24/2002 JRI4 Action: AP Item: 05500 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BI-,DG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-'IAr'ICE' Cond:22 (BLDG.): COMBUSTIONAIR IS REQUIRED PER SEC. 701 OF THE 7997 VMC, OR SECTION 701_ oF THE 1997 rMC. Cond:23 (BL,DG. ) : INSTAL,L,ATION MUST CONFORM TO MANUFACTURES INSTRUCTIONS AND TO CHAPTER 10 oF THE 1997 UMC, CHAPTER 10 OF THE 1997 rMC. Cond: 25 (Br,DG. ) : GAS APPr-,rANcEs Aoo BE vErqTED AccoRDrNG ro cktsn I AND sr{Arrr TERMINATE AS SPECIFTED IN SEC.8O5 OF THE 1997 I]MC, OR CHAPTER 8 OF I'HE ].997 IMC. Cond: 29 (BLDG.): ACCESS TO HEATING EQUIPMEIc| MUST COMPLY WITH CIAPTER 3 AllD SEC.1017 OF THE 1997 I'MC AND CHAPTER 3 OF TIIE 1997 IMC. Cond: 31 (BI-,DG.): BOILERS SHAIJL BE MOITNIED ON FI-,OORS OF NONCOMBUSTIBIJE CONST. IINITESS I-,ISTED FOR MOIINTING ON COMBUSTIBIJE FLOORING. Cond: 32 (BLDG.): PERMIT,PL,ANS AND CODE ANAIJYSIS MUST BE POSTED IN MECIANICAL ROOM PRIOR TO AN INSPECT]ON REQUEST. Cond: 30 (BLDG. ) : DRAINAGE OF MECHANICAI-, ROOMS COMTAfNING HEATING OR HOT-WATER SUPPLY BOII-,ERS STIAI.,L BE EQUIPPED WITH A FI,OOR DRAIN PER SEC. 1.022 OF THE 1997 I'MC, OR :-":]-::I-i:l-1;'.l--l-1-Iij-.-'",-i-]--lT-l;'*'*.**.*|***i.'ri1:t't'+.tt.**.*lt**:*,t***:.*i*'**'+*'tt*t|**||***1**.*|*'*'*|i* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV y's on er ou* oaFrcE FRoM 8:oo AM - 4 PM. RE OF OWNEROR CONTRACTORFOR HIMSELF AND OWNEF l'************ **+****'a'*************+**** *++***+*l****+t*********++,1.*++{. *:t+lr{.**t****** +***** *+ TOWNOFVAIL. COLORADO Statement ***** ** ****** *** * * * * * * * * * * * * * * d. * * * * * * * * ** '1.********* * * * * * * * * * * * * * *,t,* *,1. * 'N( * f{.,1.****1.,}'}* * * * *{.,!*** Statement Nunber: R000003163 Anount: $28.00 09/27/200209:28 AM Payment Method: Check Init: L,C Notation: #937lSwedes Permit No: M02-0196 Drpe I MECltANIeAl, PERMIT Parcel No: 210110201009 Site Address: 2039 St IIBURST DR VAIL Location: 2039 SUNBURST DR Total Fee6: $28.00 This Payment: $28 .00 Total AIrIr Erntss: $28 . 00 BaLance: $0.00 *+++,*+*****+*********+****+******+++**++++{.1.*++++***'}******{.t**+****++***l****+***** t ******* ACCOI]NTITEM LIST: Account Code Descniption Cunrent Pmts l.4P OO1OOOO31113OO MECHANICAL PERI'1IT FEES 2O.OO PF OO1OOOO31123OO PLAN CHECK FEES 5.OO l.lc OO1OOOO31128OO WILL CALL INSPECTION FEE 3.OO APPLICA TED rF rn.o"G, oR uNsr Building Permit #: Mechanical Permit #: 97 O-47 I -2149 (Inspections) Room Room Di Air Duct Size Gas Linee Spec Permit will not be accepted without the following: CONTRACTOR INFORMATION Contact and Phone #'s: i @37 -37o-t Town of Vail Reg. No.: o- COMPTETE VATUATION FOR MECHANICAL PERMIT & Materials Contact Asgcsgots Offie at 97O-328-8640 or visit for Parel #'/ott 02o t oo L-JAU- f V S,#-. Fr-.o . ()e'.*,, WorkClass: New( ) Addition( ) Alteration( ) Repair( ) Other( ) Does an EHU exist at this location: Yes ( ) No ( )BoilerLocation: Interior( ) Exterior( ) Other( ) Type of Bldg: Single-family ( ) Duplex ( ) MultFfamily ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: of Fireolaces Existino: Gas Apoliances ( ) Gas Noflype of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) No \WaiI\dalabdev\FORMS\PERMITS\MECHPERM.DOC 07 t26t2002 TOWNOFVAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 OorooorrENr oF coMMUNrrY o#roonor* NOTE: TTIIS PERMIT MUST BE POSTED ON TOBSITE AT ALL TIMES MECHANICALPERMIT Permit #: M03-(*"t-il"ti 3o2osf5- fob Address: 2009 SUNBURST DR VAIL Status . . . : ISSLIED Location.....: 2039 SLINBURST DR Applied . . : 06/78/2003 Parcel No...: 210110201002 Issued . . : 06/78/2003 ProjectNo: ve$i-6iL; Expires..: 12/15/2003 otitNER sNowsroRM rJrJc o6/Lg/2oo3 phone: C/O TI'RCAN CONNEIJIJ VilS ATTTiI: RF SALTIRE CT 20 CASTI,E TERRACE. EDINBI'RGH EH1 2ET, SCOTI,AND I_,icense: coNTRAcToR Main Mechanical o6/L8/20o3 Phone: 970-984-3250 5560 County Road #335, Unit 1 New Castle, CO 4L647 I-,icense z 27L-M APPLICANT Main Mechanical O6/L8/2OO3 Phone: 970-984-3250 5560 County Road #335, Unit 1 New Castle, CO 4L647 License z 2'l L-Yl Desciption: INSTALL SNOW,ELT ON LANDING AND STAIRWAY LEADING ONTO BACK DECK Valuation: $1,000.00 Fireolace Information: Restricted: Y # of Gas Appliances: 0 # of Gas logs: 0 # of wood Pellet: **r**** FEE SUMMARY Mechanical--> Plan Check--> Investigation-> Will Call---> $48.00 s0.00 s48.00 $48.00 so.0o $20.00 Restuarant Plan Review-> $5.00 DRB Fee------> $20. oo TOTAL FEES-----> $3.00 90.00 Tota] Calculated Fees-> 9o . oo Additional Fees-> 948 . 00 Total Permit Fee--> PaYmentsr---> BALANCE DUE-> Item: 05100 BUILDING DEPARTMENI o6/L8/2oo3 DF Action: AP Item: 05600 FIRE DEPARTMEMT CONDITIONOF APPROVALCond:12 (BI-,DG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-,IAITCE. Cond:. 22 (BLDG.): COMBUSTIONAIR IS REQUIRED PER SEC. 701 OF TI{E 1997 IIMC, OR SECTION 701 0F THE l_997 rMC. Cond:23 (BLDG.): INSTALLATION MUST CONFORM TO MANUFACTITRES INSTRUCTIONS AIID TO CHAPTER 10 oF THE i-992 uMc, cHApn 10 oF THE t-9e7 rMc. Cond: 25 (BL,,DG.): GAS APPI-,IAIICES SHALL BE VENTED ACCORDING TO CHAPTER 8 TERMINATE AS SPECIFIED IN SEC.8O6 OF TIIE 1997 I,MC, OR CIIAPTER Cond:29 (BI-,DG.): ACCESS TO HEjATING EQUIPMENT MUST COMPLY WITH CHAPTER THE 1997 I'MC AND CIAPTER 3 OF THE 1997 IMC. Cond: 31 (BLDG.): BOIL,,ERS SHAI-,L BE MOITNTED ON FIOORS OF NONCOMBUSTIBIJE CONST. IJNI-,ESS I-,ISTED FOR MOI]NTI}IG ON COMBUSTTBIJE FI'OORING. Cond: 32 (BI-,DG.): PERMIT,PI-^AIIS AIID CODE AIiIAIYSIS MUST BE POSTED IN MECIIANfCAI-, ROOM PRIOR TO AN TNSPECTION REQUEST. Cond: 30 (BIJDG. ) : DRAINAGE OF MECHANICAL ROOMS CONIAINING HEATING OR HOT-WATER SUPPLY BOII,ERS SIIAT,I, BE EOUIPPED WITH A FIJOOR DRAII{ PER SEC. LO22 OE THE L997 I'MC, OR SECTION 1004.6 OF TI{E L997 IMC. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the inforrration as required is correct. I agree to comply with the inforrration and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Unilorm Building Code and other ordinances of the Town applicable thereto. AIiID SIIAT,IJ 8 OF TTTE 1997 TMC. 3 AIID SEC.1017 0F ') REQUESTS FOR INSPECTION SHALL BE MADE TWENry.FOUR HOURS IN ADVANCF,-BY PM, TURE OF OWNEROR AT 479-2149 0R AT OFFICE FROM 8:00 AM - 4 ') -/ ', HIMSELFAND OWNEF AppucATt wrlr Nor BE AccEprED rr rn"on#, o*-6v>{ TVWII0FUtn 75 S. Frontage Rd. Vail, Colorado 81657 Permit will not be accepted Room Di Spec Sheets Building Permit #: MechanicalPermit #: 97 O- 47 9 -2149 (Inspecti ons) nclude: tr tr tr D CONTRACTOR INFORMATION Mechanical Contractor:-nl;rt-frii'i"illonic, ( Town of Vail Reg. No.: VW "qil:'i:';" g-" ce H'7s E-Mail Address: contractor t'nnu*"'/ J;rrro/. 4/ ^ r MECHANTCAL: $ hrpot. s l.m. COMPLETE VALUATION FOR MECHANICAL PERMIT bor & Materials usE oNLY** *************************** Contact Aswsrc Office at 970-328-8640 or visit for Parcel # robAddress: g@q5r"6r,Job Name. Snonrsia r rn 'J^sl*tt S^ou;rr^e(f or (-. ^)i^5 e, sQ'+;e'^''*l lt^Ji'5 "*;}:* WorkClass: New(Y) Addition( ) Alteration( ) Repair( ) Other( ) Does an EHU exist at this location: Yes ( ) No ( )Boiler Location: Interior (,[) Exterior ( ) Other ( ) Typeof Bldg: Single-family0d Duplex( ) Multi-famiV( ) Commercial ( ) Restaurant( ) Other( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: Nofrype of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) ffiood burning fireplace to an EPA Phase II device? Yes ( ) No **:r.* **********:r *******xxFoR oFFIcE \WAi I\d8tA\CdCV\FORMSWERMITS\MECHPERM. DOC 0126/2002 '1 ,,i !:i l. l:.:i TOWN OF VAIL 75 S. FRONTACEROAD vArL. co 81657 970-479-2138 Job Address: 2009 SUNBURST DR VAIL Location.....: 2039 SUNBURST DR Parcel No...: 210110201002 Status...: ISSUED Applied. . : ll/20/2003 Issued..: 12/03/2003 Expires . .: 05/31/2004 lL/20/2003 Phone: 97o-984-3250 Qrro*r" ENr oF coMMrJNrrY oe#op^a eNr NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M03-0249 t r3ax<'xir t-$z<:155- projectNo, ?\elOX _ O lXf OWNER SNOWSTORM LLC LL/20/2003 Phone: C/O TURCA}T CONNEI,I, WS ATTN: RF SAIJTIRE CT 20 CASTLE TERRACE, EDINBURGH EH]- 2ET, SCOTI,AND License: COIfrIRACTOR Main Mechanical LL/20/2003 Phone: 970-984-325o 6560 County Road #335, Unit 1 New Castle, CO 4L547 License:. 271--14 APPLICAT{T Main Mecharri"cal 6550 Courty Road #335, Unit 1 Nevir Cast1e. CO 81647 Li-cense z 2'7L-Y! Desciption: ADD BOILER FOR SNOWMELT IN GARAGE Valuation: $4.000.00 Fireplace lnformation: Restricted: Y # ofGas Appliances: 0 # ofGas Logs: 0 d of Wood Pellet: 0 *r:l t*'t *t*at*:l t*t:l r:tt r *:i r:ta *:i t*ra *:r Mechanical---> Sso. oo Restuarant Plan Revie$'-> $0 . 00 Total Calculated Fees--> $103 . 00 Plan Check--> $20. oo DRB Fee------------> $0 .00 Addilional Fees------> S0 . 00 Inyestigation-> So . 00 TOTAL FEES------> $103 .00 Total P€mit Fee-----> 5103 . 00 Will Call---> $3.00 Payments-----------2 $103.00 BALANCE DUE------> So. oo *lt+*+t+|t+ttlttlltill||itlltl+*tltt+ti+tillt|*.ttttlti|*ttlt'l*lttt.lltt|tt|.*t|*.|'tt*tt|'tit**.t.+l**lItem: 05100 BUII-,DING DEPARTMENT LI/24/2oo3 rRI( Action: AP Item: 05600 FIRE DEPARTMEM| CONDITION OF APPROVALCond: 12 (BI-,DG.): FIEL,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-,IANCE. Corrd: 22 (BL,DG.): coMBUSTToNATR rs REQUTRED PER sEc. 701 oF THE 1997 uMc, oR sEcrroN 701 0F THE 1997 rMC. Cond: 23 (BL,DG.): INSTAL,,I,ATION MUST CONFORM TO MANUFACTITRES INSTRUCTIONS A}{D TO CHAPTER 10 OF THE 199? I'MC, CHAPTER 10 OF THE 1997 IMC. Cond: 25 (Br-,DG.): GAS AppLrANcEs !}r" BE vENTED AccoRDrNc ro chiren I AlrD sHA.r-,L TERMINATE AS SPECIFIED IN SEC,8O5 OF THE 1997 I'MC. OR CHAPTER 8 OF THE 1997 IMC. Cond: 29 (BI-,DG.): ACCESS TO HEATING EQUIPMENT MUST COMPLY WITH CHAPTER 3 AIiID S8C.1017 OF THE 1997 I]MC AND CITAPTER 3 OT' THE 1997 IMC. Cond: 31 (BI-,DG.): BOILERS SIIAIJIJ BE MOIINIED ON FIJOORS OF NONCOMBUSTIBLE CONST. IINI,ESS I,ISTED FOR MOT'NTING ON COMBUSTIBI,E FI-,OORING. Cond: 32 (BL,DG.): PERMTT,PLANS AI.ID CODE AIIAIJYSTS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQI'EST. Cond: 30 (BI-,DG.): DRAINAGE OF MECHAIIICAL ROOMS CONIAINING I{EATING OR HOT-WATER SUPPLY BOII-,ERS SI|ALIJ BE EQUIPPED WITH A FLOOR DRAIN PER SEC. LO22 OF THE 1997 UMC, OR SECTION 1004.6 0F THE 1997 IMC. l a+la +t,l *'r * tl *t,l * DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure accprdingto the tow'i zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances of thdTown applicabld/rereto. ,/ REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS ANCE BY, SIGNATUREOF OWNEROR .fA OFFICE FROM 8:00 AM - 4 PM. FOR HIMSELF AND OWNEF **** ********* *********+**f***+***********ff,**ta******+*++*****+****** ** *****at***+*********+ TOWNOFVAIL. COLORADO Statement * *+ * *** * * '} *** * ** * * * ** 'i:r.* +****+ +* +*** * * * ** ** **** t* * * *+* ** * ***+** *** *+* * **** * * ** * f + ** +*** * * * ** Statement Number: R030005227 Amount: $103.00 L2/03/2OO3t1 :53 Al'l Pal'ment Meehod: Credit Crd Init: DDG Notation: Rbrock Hays Permit No: M03-0249 Type: MECIANICAJ, PERMIT Parcel No: 2IO!7O2O7OO2 Site Address: 2009 SIINBITRST DR VAIL Irocat.ion: 2039 SIINBIIRST DR Total Fees: $103.00 This Pa)ment: $103 . 00 TotsaI ALr., Pmts: $103 . 00 Balance: $0.00 +*:f++ + *** * * * ** * * ** + + |t *+ t * * ** ** * ++*+ * ** ** **** t ****'i * ****** * * *****++*** ** * * **** f ++** * *+ * *** * * * ACCOUNT ITEM LIST: Account Code Descr'iotion Current Pmts MP OO1OOOO31111OO I4ECHANICAL PERMIT FEES 8O.OO PF OO1OOOO31123OO PLAN CHECK FEES 2O.OO LiC OO1OOOO311Z8OO WILL CALL INSPECTION FEE 3.OO AppucArl wrLL Nor BE AccEprED rF rNcoMlE oR IVWNOFTIIN 75 S. Frontage Rd. Vail, Colorado 81657 ,t toEv Mechanical Permit #: 97 O-47 9-2149 (Inspections) Permit will not be accepted without the following: Provide Mechanical Room drawn to Duct Size Gas Line CONTRACTOR INFORMATION ,32 COMPLETE VALUATION FOR MECHANICAL PERMIT MECHANICAL: $ {4i",+4eJ 4 4, Ouot -/,^etmpl.ri+- Contact Assessorc Otrrce at 970-328-8640 or visit for Parel # Parcel # p oLo to robName: (,il,UrlerS$pn Job Address: 2O3? Soo /rrs/ -b_Ue Owners Name: 1,'n (nardn Address: (ln(aouutt ot*o'rt /oo Bo,lr.r Sno"Ji,a(i/ iX" Gko->c WorkClass: New() Addition()Q Alteration( ) Repair( ) Other( ) Does an EHU exist at this location: Yes ( ) No (Boiler Location: Interior (f,) Exterior ( ) Other ( ) Typeof Bldg: Single-family( ) Duplex( ) MultFfamily( ) Commercial ( ) Restaurant( ) Other(/J Gr+?jge No. of Accommodation Units in this building: -TNo. of Existing Dwelling Units in this building: -Y Gas Loqs ( ) Woodi Pellet ( ) Wood Burni Noflype of Fireplaces Proposgfias Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a to an EPA Phase II device? Yes ( ) No ,A,iw \\VAiI\dAIA\CdEV\FORMS\PERMITS\M ECHPERM.DOC 01/26t2002 wwhrl fizsru(aapAWt4lbvrpGw <tDwr4k w-twu,fl n1+ I'rL P lqq kL (r**) 7 t ) ?.ct-|e ft+ alpeaatt- 14a ljv - 6,o # * llo,ooo Vr,rL od g,* LltrL174ewtf \44* tr' . 6 q . 1ry;a Ul"L t|.lpvt q6{,5e 4t11'5q btvb ffi , e<n/19 t,*vt (w*l trvow*!) {rwvn 7 Grv-b't 26J54'oc' 2&51'0" 4, 111pw .a,1b , o,O1+ = i1i,14b P,fv* 1 t 'ae,if 4+a,7zb vH/ ah^t -Q1Z'-A" '' - 1Co -6; (A|;f,oo ;{:;,; - +14i15 Vfvr- (+rrrr*.vt 4721tpt"i\ ftLsev rt ( PatW*, b-*oqp (&rooo, o.$.o.ta€ = In1rlltc VX1H ffig;wr\," t*1 *F 4772 336a TOWN OF VAIL 75 S.FRONTACEROAD VAIL, CO 81657 970479-2138 Qrro*rru*T oF coMM'** oruull,rr t NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PLUMBING PERMIT Permit #: P02-0105 Job Address: 2039 STJNBURST DR VAIL Status . . . : ISSUED Location.....: 2039 SUNBURST DR Applied . . : 08/26/2002 Parcel No...: 2l0l 10201009 , lssued . . : 08/2812002 ProjectNo: {UsoZ-oLL} Expires..: 02/24/2003 COMTRACTOR I-,ORTON PLWBING TNCORPORATEDOS/26/2002 Phone z 970-32A-59O0 P.O. BOX 3635 EAGLE, CO 81531 I-,icense z 255 -P APPI-,ICAIiTT I,ORTON PLWBING INCORPORATEDOS/25/2002 PhONEI 970-328-5900 P.O. BOx 353s EAGITE, CO 81-631 License: 255-P owNER PTERCE, MARITTA 08/26/2002 Phone: PO BOX r-r_23 VATL CO 8165I License: Desciption: rework plumbing systems to accomofate new layout per archtects plgs Valuation: $9,200.00 Fireplace Information: Restricted: ?? # ofcas Appliances: ?? # ofGas Logs: ?? # of Wood Pallet: ?? *1|*.t't++|:t+*.+|*.*'t.t+.|*.|*'+li++t,|t|.|.|:t.ttl.t'}.|*l'||++l*||l*++.| Plumbing--> g15o - OO Rcstuarana Plan Review--> SO . OO Total Calculated Fees---> $1.90 . 50 Plan Check--> $3?.50 DRB Fee-----------> $0. o0 Additional Fees--------> $55.00 Investigation-> $o - oo TOTAL FEES-------------> S19O . 50 Total Permit Fee--'---> $245 . 50 Will Call--> $3 - oo Payments----------'-;' 5245 - 50 BALANCE DUE------> $o. oo *,* *t *t t * at * ++ * +atItem: 05100 BUII-,DING DEPARTMENT 08/26/2002 DF Action: AP Item: 05500 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BI-,DG.): FIEI-,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPIJIANCE- DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code ""?n", ordinances of the Town applicable rnt REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADVANCE BY ATt79-2138 OR AT OUR OFFICE FROM 8:00 AM - 5 PM. SICNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNET ** *{t't*** ****+***t'l {r * * * * * * * * * * * * t * {! + + +* ** * * * * * * * * * * ** * * * * * * * 't 't * * * * * * * * * * * * * * * ***+'} **+'*+** **,}+ TOWNOF VAIL. COLORADO Statement * * * * + * * **** **{. * * ** * *** +**** * * + t* * ** * *+ * * * ** t * t * **** * * ** * * * *t + * * ** * * * ** * .t t ** *,} * ** ***+ * * + ++ * * * Statement Number: R0000029?? AnounE: 5245.50 0e/28/200202228 P{r Pa)ment Method: Check Init: LC NoEation: #5585,/LorEon Plurnbing Permit No: P02-0105 T14)e: PL,IIMBING PERMIT Parcel No: 210110201009 Site Address: 2039 SIINBURST DR VAIL Irocation: 2039 SITNBITRST DR Totaf Fees: 5245.50 This Payment: $245.50 Total ALL Pmts: $245.50 Balance: $0.00 *** * * * ** * * ** * + * *f * + 'f+ * * * ++ * * * ** * * * ** ** ***** * * *** * * * **+ * *+*** **++ ************f,t*****it* **{.**** ACCOIJNT ITEM LIST: Account Code DescriDtion Current Pmts cL 00100003123000 c0NTMcrOR LTCENSES 55.00 PF 00100003112300 PLAN CHECK FEES 37.50 PP OO1OOOO31112OO PLUMBING PERMIT FEES 15O.OO l^lC 00100003112800 WILL CALL INSPECTION FEE 3.00 .ftfi4,6n,,@*APPLI 75 S. Frontage Rd. Vail, Colorado 81657 Building Perhritfl62.,CrZN Plumbing Permit #: 97 O- 47 I -2149 (Inspections) Plumbing Contractor: LOKTDNT.;"IIB\Nq .T^L Town of Vail Reg. No.:z€.€.Q Contact ar =ffo rd Phone #'s: l3ZB strCr> contractort'nffi ,A COMPLETE VALUATION FOR PLUMBING PERMIT (tabor & Materials) PLUMBTNG: $ q,2@. OO Assessorc Office at 970-328-864O or visit Parcel # (Required if no bldg. permit # is provided above) 7rO\- \OZ-()\ - Job Address: r,-3q 3o)NE.,gsJob Name: V\,*re.G- abe.< -vlu'tBrxrn SYST€r-\S -rc WorkClass: New( ) Addition( ) Alterationft Repair( ) Other( ) Type of Bldg.: Single-family ( ) Duplex F-1 -MultFfamiV ( ) Commercial ( ) Restaurant ( ) Other( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: Z Is this a @nversion from a wood burning fireplace to an EPA Phase II device? Yes ***************************************FOR OFFICE USE ONLY***********r.******t<****************** Town of Vail RECEIVED AUG 2 2 7007 TOV-COM.DEV. F/areryone/forms/plm bperm OFFICE COPY i rl (t lqry';ffr--|n9pc(donRequestnepomns -.- --------Taser 6:57 am __ __-___- - VAIL, QCL:JjIWIIOE_ - Requesbd tnsp€ct tlatei Fr{.tty, December {2. 2003 Inso€c0on ArE : CO Slte Addrclci 2009 SUt{8l,rRST OR VAIL 2039 SUIIBURST DR ArPrD lnfrnmtlon Ecq gm.g211 Occrpai*y: Ty?e:}BIJ[,D Sr.d, TlDo: ASFR[fte: VN Phone: 970-44$1ml Shfrrs: ISSUEDhspAn: cD Ownen PIERCE. i'ARITTA D€cfF[on: hIIERIOR RETIIOO€L: TIASTER EEDROOTI/BA.TTI LOYi,ER LEVEL BATTIS,DRYVI'ALL PANT,CARPET itEyv Bot_ER StIOI\lSTOfiMLLC NEDmCOiISTRTJCTTOil NEDSOCONSIRUCT|ON : NEOBO r.rcTtoN Cofl||fl€rI ROI.JTED TO C}IARLE FOR REVEW/AT,PRCh/ALS 2&FLORES,n*,6{-\ $"Dpl6uw re# s0 Bt.DGrttrrt ./ | \\ \ --l-\n"ou€eEdrtme: 6:0oAu Phon€' 977-GnB ^ffii#ftffffiXtit*" /l ( I / Enreredgy: DGoLDEN K Acto{r: lnEoac0on tllsbrY t!$r: 5il) lbm: S BLDG-Flml lbm: gl 8lo&Flamlm *tupord* lolixttuz -lr|rD.don JRM ' Acton' AP APPRoVED lt m: 50 BLOG'h3uHion Ar9ro\d "lry:[y(E Insg*tof: JRfi- Acilon: AP APPRC]VED C.ommeils: APPRO1IED WITH CORRECIIOI.IS TO ADO NAT. PTAT€S I,PSTARS BAT}FOOTI. ADCESS PAI.IEL REOTJIRED FOR BOOSTER FAI{ LOCATIC'{lfii: 6OBLDG..Sh.crrektJrll -Ap0rorr.d" 11io7fi2 lffpecbf: .Ril " irn: 7ll BLDGlffEc. Actixt' APAPFROVED 1ll11l02 ltEp.clor: @D Actbfl: i{Ol{ClTFlED ConnrmE: CCf,JTERSY WALK T}fiOTJGH RE: TTYNOOVY WELT A}ID DI}GNS}TOT€ BLDOTomD.C/o 12t12tfl, Ew*iz--nbiiil tI.aor, caoff-'* Adon: APAFPRovED r^vf,lFGonmcnb: Coinpl* Ur€ lrllidlrtlon of hrnd''ll d sillhs fiom dinlog rcoF-l {ry l: 'r-ApproGd " ffitrffi snch&mil6ri.ivry:y*drubec.cufc€ncdc3ndcofiiffit/ {)@.Nts- uncwer grom od6irore pd-n-tirrftcy dsr nnd clfli L/ DO*l ,L .). i. f REPT131 Rlrn Id.: L472 O oo ooO OOoo oooo oooo 12-12-2003 hspectlon Request Reportlng Page21 -Q:slern--- -___-ltatL-c.a--loMtloE _ ------ A.ttft Cond TyrF: Clniicr: hf InrnccilonH|sm ArPID lnlbflnttbn ht|: 2m lnn: ASFR s$,r: EtBtEDhryArE: GD Rcouerbd lncmc{orils! lb|firRque$r: Cofrimar*: Aeelgned To: Acfofl: gts96+3i?60 97S96+3450o0nosrc|(D€eK Rtqn chd nme: 08:00 Ail' PiEn€r +r- 971{128 Enbmd$: DGoLDEN K lln: &In: nam:lhn: lbm: RequesEd hrp€ct Qde: t{day, t}ecetnber 12, 2003' hs9ec0onArca: GDSlbAddnct: 2009 SUfg,rRS'T DR vAlL 2039SU'{BTTFTDR 3gi t{EcH+kld Grw - Neobo udtrcd 15 nth drd 977-{XEB TbnrEp; 310 ilEcl.l-t{€€tfrlq " ADotonrd -0glSl03 hroecbr: CDA\]E Acdon: APAPPRCn/ED Cornm.nb: st$Utt iaELT oN sTAns usltfci EXGSTS\E 8(,|.ER 9S'ARTEST 3ll5 Ftti|&grbPtsfiU 3aO ilEct{-E*nurt tjbodif,n rGCFI-SupolyAf3# tt€C$HEc. - 3OO i,GCl+Fin l AEdon: DNDET{ED Co{r*mn|3:AFEA IYTGRE WORI(ERS YTIERE YUORI(hIG WAS T.IOT T.IOT READY. WOR(ERS O|) M)T INO{CATE A}.IOTTER AREA TO B€ FISPECIED Dotcrlpn: REPT131 Rrrn Id: 1412 -7 lo ?o t, It TOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2t38 puilRrNas*r oF coMMUNrrv oBvrr.oprtr NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES PROJECT TITLE: ADD/ALT SFR BUILD PERMIT Permit #: 801-0021 Job Address: 2009 SUNBURST DR VAIL Status . . . : ISSUED [ocation.....: 2009 SLINBURST DR Applied. . : 02/07/2001 Parcel No...: 210110201002 Issued . . : 02/1512001 ProjectNo : Expires. .: 08/14/2001 OWNER SIIOWSTORM LLC 02/07/2007 Phone: c/o TURCAII CONNELL., WS ATTN: RF SALTIRE CT 20 CASTLE TERRJACE, EDINBURGH EH1 zET, SCOTL,AIID License: corfrRAcToR NEDBO CONSTRUCTTON 02/07/2007 Phone: P.O. BOX 3419 VAIL, CO cEr,r,# 471-4888 81658 License:251-A APPIJICANI NEDBO CONSTRUCTION 02/07/2001 Phone: 970-845-L001 P.O. BOX 34r.9 VAIIT, CO CELL# 471-4888 81658 License; Desciption: ENLARGE BEDROOM/REMODEL BATHOccupancy T)rye Faceor Sq Feet Totals, . . $75,000.00* Number of Dwelling Units: I Town of Vail Adjusted Valuation: $75,000.00 Fireplace Informalion: Restric'ted: Y # ofGas Appliancts: 0 # of Gas L.ogs: 0 # of Wood Palle[ I FEE SIIMMARY O.^-^\ D"S. .( S$ L.,f ,st-' Building-> 9515.00 Restuaranl Plan Review->S0.00 Total Calculaled Fe€s-> $1,117.75 Plan Check-> 5399.?5 DRB Fe€------> 91OO.OO AaLlilional Fees-> So . oo Rec,reetion Fee-------> 53. oo Clean-up Deposit----> so.0o SO . OO Tolal permit Fe€_> S1, 112 .75 90.00 Palmer s------.-> 51,,1f7.15 9O.0O Invedigation-> will call-> TOTAL FEES--------> S1., x1? . ?5 BAI-ANCE DL'E - Aonrovals:If6m: 05100 BUILDING DEPARTMEX\TT O2/07/2O0L K!{ARREN AcEion: NO ROIITED TO JR AND BILL FOR REVIEW O2/L5/2O0L jrm Actsion: AP PI-,ANS RED I-,INED It.em: 05400 PLANNING DEPARTMENT 02/08/2O0L bg AcEion: APPR Item: 05600 FIRE DEPARTMEIfiI Item: 05500 PIIBLIC WORKS See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in firll the information requird completed an accurate plot plan" and state that all the information as required is conect. I agree to comply with the information and plot plaq to comply with all Town ordinances and staie laws, and to build this structure acmrding to the towns zoning and subdivision codes, design rwiew approvd Uniform Building Code and other ordinances ofthe Tovm applicable thereto. 8:00AM-5PM.REQUESTS FOR INSPECTION SHALL BE MADE TWENry.FOUR HOI,'P.S S€d Clean-up D€posit To: N/A IN ADVA},ICE BY TTJRE OF O CTORFORHMSELF AND OWNE ** * * 't * 't* t I f* i**t * ** ** * * +* ** * *:t't PAGE2 * ** * *'ll +t{r t * t+**** ** {r't'f**:f*'f*** t*** t t * +**:l** * 'F*l'* *,}l' 't I * l* CONDITIONS OFAPPROVAL Perrnit#: B0l-0021 asof02-15-2001 Status: ISSUED ** ** * * * *'l * * * * * * * * * * +** ** * * * * **'r* * ***** ***** ** * * * * * ** * * * * * *'l* * * * * * * * **** +*** * *** * * **'l * * * *** ** * * ** * * +* * * * * Permit Type: ADD/ALT SFRBUILD PERMIT Applied: 0210712001 Applicant: NEDBO CONSTRUCTION Issued: O2ll5l200l Job Address: 2009 SUNBURST DRVAIL Location: 2009 SLINBURST DR ParcelNo: 210110201002 * * * f ** * * * * * * *'t + * ** * * * ** * **** * * * * * * * * * * * * * * * * **** * * * * * * * {t*'t * * 'l {t 't 'l * *:f * ** * * * * * * * * 'lt *:t:l * ** * * * * * **'* * {t*'f' 'l '}'l 'l'} * * CONDITIONS ** ** ** +* * * +* **+ * * ** ** * * + * * ** * * * * t * * t * * * * * * * * **** * {r * * * * * ** * * * * * * ** **** * * * * * * * * ** * * **** * * ** **'t'* **:* * **'} ** ** Cond: 12 @LDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLLANCE. Cond: 16 (BLDG.): SMOKE DETECTORS ARE REQI.JIRED IN ALL BEDROOMS AND EVERY STORY AS PER sEc.310.6.l oF THE 1997 t BC. **,N'*'i't*'t,i*i.******t**!t{r*'}**f***a**********t!t****t**,}***'t'}lr'*'}'tt*Q*a******'t*:t:t't'lr*{r't'}*:t'*lt TOWN OF VAIL, COLORADOCopy Reprintcd on 02-15-200t et 10:53:24 02ll5l20/0l Statement *** ***:t * *t**:* +*'f **+****+*****+****'lt *,lr*i*:i!t**+ *'r:****** * ** * * *,i '} {.,1'i * +,1* * * ****** * ****'1,1. *'t,}'l *'t'}{t Statsement Number: R00000045? Anrount: $1.117.75 02/L5/20Ol]-O:52 Alt Pa)ment Method: Check Init: KMI{ Notation: *19535/Nedbo Permit No: 801-0021 Type: ADD/ALT SFR BUILD PERI,IIT Parcel No: 2101102010 02 Site Addrees: 2009 SIINBTTRST DR VAIL I-.ocation: 2009 SIJNBITRST DR Total Fees: $1,117.75 ThiE Payment: $1,117.?5 Total AL,Ir ttnEs: $1,11?.75 Balance: 90.00 :f tl ***t,t **l*'f **l't **t+'t**i****t't***** * *'f*t!*'**{r**'r *'1.**{r{r,}*l***!***:l:t{.*'l' * *{t** * **t'l't t**'}{.'t{t'rl.'r{t'}'} ACCOUNT ITEM LIST: Account Code Description Current Pmts BP OO1OOO()3111iOO BUILDING PERMIT FEES DR OO1OOOO31122OO DESIGN REVIEW FEES PF 001000031i2300 PLAN CHECK FEES t|lc OO1OOOO31128OO l..lILL CALL INSPECTION FEE 615.00 100 .00 399 .75 3.00