HomeMy WebLinkAboutVAIL LIONSHEAD FILING 1 BLOCK 1 LOT 3 VAIL 21 BREEZE SKI RENTALSTOWN OF VAIL DEPARTMENT OF COMMUNIry DEVELOPMENT 75 S,FRONTAGEROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TMES PLUMBING PERMIT Permit #: P07-0193 Job Address: 521 E LIONSHEAD CR VAIL Status . . . : ISSUED Location.....: VAIL 2l BLDG-BREEZE SKI RENTAL Applied. . : ll/0712007 Parcel No...: 210106403001 Issued . . : ll/07/2007 Legal Description: Expires . .: 05/05/2008 ProjectNo : (QU:56V -Otto(J2 osrNER EREMTA, SORIN - VANHOTJTEN, Srt/O7/2O07 HAWKSLEY, CLEMEMTINA W. -TRUSTEE 1572 .TESSAMYN CT RIVERSIDE cA 92506 APPI,ICANT MEADOW MOUNTATN PLUMBING,/HEAII/ 07 /2007 PhONC: 97O-479-298L P.O. BOX 4554 VAII-, co 81658 License:288-P COIITRACTOR MEADOW MOT'NTAIN PI-,I'MBING/HEAIL/07/2007 PhONE: 97O-479-298]- P.O. BOX 4554 VAIL co 81558 Llcense: 288-P Desciption: RELOCATE WATER CLOSET AND LAVATORY FOR ADA BATHROOMS FOR THE BREEZE SKI RENTALS INTERIOR TENANT FINISH Valuation: $2,850.00 FireDlac€ hformation: Restricled: ??# ofcas Applianc€s: ??# of Gas Log: ?? # of Wood Pallet: ?? l:t+'i:r t* *:t* *t i:t llt +*'r l* l *a*l a1*a *lrt Plumbing-> Plan Check--> lnvestigation-> Will Calt--> 945 . 00 Restuarant Plan Review-> $11.25 TOTALFEES > $0.00 94.00 $0. oo Totalcalculaaed Fees--> $60.2s AdditionalFe€s--> Total Permil Fee----> Palments-._-_> BALANCE DUE-> $60.2s $0. 00 s6o.2s $60.2s 9o. 00 *:t* *a:l rla r't l+*+ir +Item: 05100 BUITDING DEPARTMEIff| Ll/ 07 /2007 cgunion Action: AP Item: 05500 FIRE DEPARTMEMI CONDITION OF APPROVALCond: l-2 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the infonnation required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, desigrr review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. REQtJESfii FOR INSPECTION S}TALL BE MADE TWENTY.FOUR HOI'RS IN ADV TELEPHONE AT 479.2149 OR AT OUR OFFICE FROM E:()O AM - 4 PM. OF OWNER OR CONTMCTOR FOR HMSELF AND OWNEN * ***r** ****+*l** * ***la**lal* *f a't*l*ll*lllltl*l*llllallllalllaa* * * a * a * | t t * + * * * * * * * | | * * t a * t * a a TOWNOFVAJL, COLORADO Statemertt l'l't ll**i * *** ** | *r**';* * * ** I tl ll *l | | | * * | ****l******** * + t t{ tt{ tl l* I I l* * *lar+*** * *tt******* * * * * * * SCaLemenE Number: R0?00024?0 Anount: $60.25 LL/07/2OO702:35 PM Payment Methods Check ck 10897 fniE: LT Notation: Meadow Mountaj.n / Permit No: Parcel No: Sit,e Address : Location: This Payment: ACCOUNT ITEM LIST: Account Code PF 00100003112300 PP 00100003111100 wc 00100003112800 DeEcript ion P07 - 0193 Type: PIjTMBING PERMIT 2101- 064 - 0300- 1 521 E IJIONSHEAD CR VAIIJ VAIIJ 21 BIIDG-BREEZE SKI RENTAL $50,2s 'tt'lt 'li'ttt t * * * ** i*'i*tt l' tt * i {' tt I | 't I | | * ** ****'t*'t!t**rt't't + * I {' * {' * * * * * * * * * 't 't f 't'tr*'t't* * * ****rtllr | {' * **** TotaL Fees: TOTA1 AIJIJ PMTS : BaLance : $50.25 $50 .2s $o. o0 Current Pmtg PI,AI{ CI{ECK EEES PI,I'MBTNG PERMIT SEES WILI, CAI.I. INSPE TION EEE 11.25 45.00 4.00 APPUCATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIqNED Project #: Building Permit #: Plumbing Permit #: 97 O-47 9-2I49 (Inspections) 75 S. Frontage Rd.Rr orgS Vail, Colorado 81657 CONTRACTOR INFORMATION PLETE VALUATIOT{ FOR PLUMBING PERMIT (Labor & Materials) Contact Person and Phone #'s: ?l-aaza contractor signatu-re: g/r".> & forhtel # rob Mdress: rLi i;;?'tr, uJob Name: $76eze 5t; K'zAf z:32v - S^?t? '(r- z/or,,f 4 /ar, WorkClass: New() Addition( ) Rltention(X1 Repalr( ) Other( ) Typeof Bldg.: Single-family( ) Duplar( ) Multi-famlly( ) Commercial pd Restaunnt( ) other( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: boLf *rr vl-EL:f u 20CI7 rolryI': :-?[ YAIL F:\cdev\FORMS\PERMm\Building\plumbingjermit_1 1-23-2005.doc Page 1 of 1 Ltl23l2005 ,-\- KI\'r.At$d,) nnrfriffi! HOW DIDWE RATE WTTH YOU? Town of Vail Survey Commu nity Development Department Russell Fonest Direstor, (970) 479.213e Check allthat applies. 1. Which Departnent(s) did you contact? Building _ Environmental _ Housing_ Admin Planning DRB PEC --2. Wasyourinitialcontactwilhourstafiimmediate_dow_or i .,,, no one available ? 3. lf you werer required to wait, how long was it before you were helped? 4. Was your project reviewed on a timely basis? Yes / No lf no, why no? 5. Was this your first time to file a DRB app_ PEC app_ Bldg Permit- I'l/A 6. Please rate fie performance of he staffperson who assisted you: 54321Name: (knowledge; responsiveness, availability) 7. Overall efiectiveness oi tre Front Service Counter. 5 4 3 2 1 L What is the best lime of day for you to use the Front ServiceCounter? : 9. Any comments you have which would allow us to beter serve you nexttime? Thank you for taking the time to compleb tltis survey. We are commithd b inproving our service. TOWN OF VAIL DEPARTMENT OF COMMLINITY DEVELOPMENT 75 S.FRONTAGEROAD vArL, co 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M07-0318 Job Address: 521 E LIONSHEAD CR VAIL Status . . . : ISSUED Location.....: VAn-21BLDG-BREEZE SKI RENTAL Applied..: 1110712007 Parcel No...: 210106403001 Issued. . : ll/07/2007 Legaf Description: Expires . .: 0510512008 Project No { pSlJ \ - 6L.t3 OWNER EREMIA, SORIN - VANHOIJTEN, SL7/O7/2007 HAWKSLEY, CIJEMENTTNA W.'TRUSTEE 1572 .JESSAMYN CT RIVERSIDE cA 92506 APPLICANT MEADOW MOTJNTAIN PLI'MBING/HF,A]-I./07 /2007 phone : 97O-479-298]- P.O. BOX 4564 VflIIJ co 81558 License z 241-Nl CONTRACTOR MEADOW MOI]NTAIN PLWBING,/HEALI/07 /2007 PhONC : 970-479-2987 P.O. BOX 4564 VAIL co 81658 License : 247,-M, Desciption: INSTALL AIR HANDLER AND EXHAUST FANS FOR BREEZE SKI RENTALS INTERIOR TENANT FINISH Valuation: $14,600.00 Fireplace Information: Restricted: # ofGas Appliances: 0 # ofGas Logs: 0 # of Wood Pellet: 0 * l *'i li * 'l,l t l,i * * f* t l Mechanical--> $3OO.OO Restuaranl Plan Review--> 9O.OO Total Calculated Fees--> g3?9.00 Plan Check--> g7s.oo TOTAI FEES------> 53?9.00 Additional Fees-----> go.oo Investigation-> g O . oo Total Permit Fee-----> 93 79 . o0 Will Call---> $4 . o o Payments----------1 93 ?9 . o O BALANCE DUE____> g0 . 00 +'tl a ar al t at al a +t a Item: 05100 BUILDING DEPARTMENT Ll/o7 /2oo7 cgunion Act j.on: Ap ITCM: 05600 FIRE DEPARTMEM| CONDITION OF APPROVALCond: 12 (BLDG.): FIELD TNSPECTTONS ARE REQUTRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2OO3 IMC AND SECTION 304 OF THE 2OO3 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALIJATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTBR 10 OF THE 2OO3 IMC., Cond: 25 (BLDG. ) : GAS APPLIANCES SHAI-,L BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BI-,DG. ) : ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2OO3 IFGC.. Cond: 31 (BI-,DG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. IINLESS LTSTED I'OR MOUNTING ON COMBUSTIBLE FLOORTNG. Cond:32 (BLDG.): PERMIT,PITANS AND CODE ANALYSIS MUSI BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECT]ON REQUEST. Cond:30 (BLDG. ) : BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED ::H:.,::.1-.?,::.:::,1-T-*-,-:l-:l::l-:-,f:T".:i:-i:fili,-l-ll1;.1;,+ii,,,i*.i**,,,,,,,*:,,..i,,.,,*,,,,,,,.,r,+,+,,,,*,,,i,,,,,* DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPESTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479.2149 OR AT OUR OFFICE FROM 8:OO AM . 4 PM. OF OWNER OR CONTRACTORFORHIMSELF AND OWNER * i * * * * * * * * * * * * * t' | * * r* {' ttt't't* * i r' * *** * *t* I 't * * * * * I I I I I I * ttt'}'rf t t *'t'f 't**t * t | | I *'l* * * ** * * * * 'l 'tlii*l* TOWNOFVAIL, COLORADO State|nent *tr**tt*ttt tt I tt**t 'r** * a* * t* * * * * ** * * ** *{'rtt**r***'t'f {' *f ***+*1* *i t { * { t rr.aaa*i * +*****l'|*'t* { |l **x* Statement Nlrmber: R070002471 J\mount | $3?9.o0 ll/07/2Oo702r37 Pt[ Palment Method: ck 10897 Check Init: LT Notation: Meadow l{ountain / $379.00 * 'l * * t * * * r * *{' 'l *{r* * * * * ** **aat* * ** ***t'*'t*t * *t * + *t t * * * lttt't**t'ttt* {rtt***** * I' I I t't'l * t * * * * * * * *l'} '}l't'l ACCOIJNT ITEM LIST: Account Code current Pmts Permit No: Parce1 No: Site Address: Location: This Payment, : MP 00100003111100 PF 00100003112300 wC 00100003112800 M07 - 0 318 Type: MECHANICAL PERMIT 2101-064-0300-1 521 E IJIONSHEAD CR VAIIJ VAIIJ 21 BIJDG-BREEZE SKI REITTAL Total Fees : Total ALL Pmts : Balance 3 DescrLption MECHAI.IICAI, PER},TIT FEES PIAIV CHECK F€ES WIITJ CAIJJ INSPECTION FEE $3?9. 00 $379. oo 90.00 300.00 75.00 4.00 APPUCATION wlLL NOT BE ACCEPTED IF II{COMPLETE OR UNSIGNED TOV Project #: -ffi Mo? .D1tg 75 S. Frontage Rd. Vail, Golorado 81657 o Flue, Vent and @s Llne Slre ando Heat loss Calcs.o EqulpmentGut/SpecSheets CONTRACTOR INFORMATION Building Permit #: l{echanical Permit #: 97 O-47 9-2149 (Inspecdorc) Permit wlll not be accepted without the following: ?r- >atta6 Person and Phone #'sl CO]IIPLEIE VATUA PERTTIIT bor & Materials or vlslt ** rl * * * ** *{. *{. * rt** tc * r}FOR #a Job Address: 12 ( .4,,1'!o1 4-,JobName: 6r.tz. St,' ("-l*7 WorkClass: New() Addltlon( ) NteradonJ)Q Repair( ) Other( ) Does an EHU e<ist at this locaUon: Yes ( ) No ( )BoilerLocation: Interior( ) Efterior( ) Other( ) Typeof Bldg: Singlefamily( ) Duplex( ) Mufti-famlly( )^Commerdal ( ) other( ) ( ) woodBuming(NOTAtIOWED) *************ffi ?BAl N OF VAIL oNLY****** F:\dgAFOR}iS\PERMITS\Euildlng\mechanlcal-pennlLlr-23-2005. DOC tu23lzoiJ' Town of Vail Mechanical Codes and Desion Criteria o You must obtain Design Review Board (DRB) approval if any of the mechanical work will involve ANY exterior work. This includes and is not limited to lcmoval and rcplacement of driveway snow melt systems. Please contact the Development Review Coordinator at 479-2128 for additional information. r The Town of Vail has adopted the 2003 InternaUonal Medranical Code and the 2003 Intemational Fuel Gas Code. r All new construction within the Town of Vail is considered to be of unusually tight onstruction, thus all combustion air is rcquired to be drawn from outside the structure for mechanical equipmenL Town of Vail Fireplace Ordinance In September of 1991, the Vail Town Council adopted an ordinance which restricts te onstructton and use of open heanfi fireplaces within municipal boundaries. Since that time the ordinance has undergone numerous changes and rwisions, striving for compromise, yet effectiveness in addressing the air quality issue. Thercfore the following criteria has been adopted: 0 Construction of open hearth wood burning fireplaces is no longer permitted within Town of Vail munkipal boundaries. Dwellino Units - Each new dwelling unit may contain: One (1) EPA Phase Il certified solid fuel burning device and no morc than two (2) gas appliances (B vent) OR Two (2) gas log fireplaces and no morc than two (2) gas appliance fireplaces (B bent). Restricd Dwellino Units - Each new restricted dwelling unit may contain: One (1) gas log fireplace and not morc than one (1) gas appliance fireplace. Accommodatiorr Units- Eadr new aooommodation unit may contain: One (1) gas Iog fireplace or one (1) gas appliance ftreplace. ff hno or more separate dwelling units or accommodation units are combined to form one larger uniq the combined unit may retain one woodburning ftreplace (if one already exists) and no more than 2 gas appliance fircplaces, or may @nveft up to two existing ffreplaces to gas. If during the course of a remodet an existing woodburning fireplace is altered or moved' the unit must then comply with all provisions of the ordinance. That is, the ftrePlace must be converted to natural gas or rFplaced by an EPA Phase II certified unit. F:\cdw\FORMS\PERMm\Building\medranicalJ)ermiLl 1-23-2005.DOC rtl23l200s TOWN OF VAIL DEPARTMENT OF COMMTJNITY DEVELOPMENT 75 S.FRONTAGEROAD vArL. co 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E07-0285 jo-t'o/8 Job Address: 521 E LIONSHEAD CR VAIL Status . . . : ISSUED Location.....: VAIL 2l BULDG VAIL SPORTS RENTAL SHOP Applied . . : 10/2312007 Parcel No...: 210106403001 Issued . . : 10/2912007 Legal Description: ,' r?.36-l --611 0 Expires. .: 0412612008 Project No :ohrNER 'EREMTA, SORIN - VANHOLTEN, SL0/23/2OO7 HAWKSLEY, CLEMEM|INA W, -TRUSTEE 1-572 ,fESSAMYN CT RIVERSIDE cA 92505 APPI-.,ICANT APBX EITECTRIC 10/23/2007 Phone: 970-252-1-620 250 Meadowwood Circle,P.o. BOx 4435 DILLON co 80435 License: 309-E COM|RACTOR APEX ELECTRIC L0/23/2001 Phone: 970-262-1620 250 Meadowwood Circ1e,P.O. BOX 4435 DILLON co 80435 License: 309-E Desciption: VAIL SPORTS-ADD 4 TRAC LIGHTS, REMOVE BOOT DRYER POWER, ADD I6 RECESSED CAN LIGHTS Valuation: $9,600.00 Square feet: 0 i t*a* **:r r* t**:i ** 'l* r:l tt*1** *:r r:i a:i* a El€ctrical-----> $218.50 Total Calculaied F€es-> 9222,s0 Investigalion--> S0.00 Additional Fees----> $0.00 Will Call-----> S4 . oo Tolal Permit Fee-----> $222.50 TOTAL FEES_> Szzz.so pay11ents.__.-__-> i222.s0 BALANCE DUE-.--> $0. OO r * 't * +* *t * rt t t t t * *+ Approvals:Item: 06000 ELECTRICAIJ DEPARTMEI{T 1O/25/2OO7 SHAHN Action: AP Item: 05500 FIRE DEPARTMENT * * 'i r:r* i * * * t + * r t * l CONDITIONS OF APPROVALCond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. * ti * t + t.l f t t,l t * a t t t DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all Town ordinances and s&rte lawg and to build this structure according to the towns zoning and subdivision codes, design review approved, Intemational Building and Residential Codes and other ordinances ofthe Town applicable thereto' REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOT'RS BY TEI.EPHONE AT 4?9.2149 OR AT OUR OFFICE FROM E:OO AIT,T - 4 PM. OWNER OR CONTMCTOR FOR HIMSELF AND OWNEB ***+*****{'** t *+tllt*r'l* t r{* * * *{' t* { * +{ *'a{'{'{'{"t{' *{'{'*la*****i'i'a'+*a++**{'*****ltt{'{'{'{'***+ *ll'{'+*a** TOWN OF VAIL, COLORADO Stat€ment ltf *ltlla*tlttr*tlttr*aatt*att**tla**a*****att+*a**t**at*a*tat * **t + + a * 't a t * * * * * a | * I I | * f, a l a | * | Slatemen! Number: R070002350 Amount! 9222.50 l0/29/2oO701 :55 PM Palment. Method:. Check IniE: DDG Notation: APex Electric 5854 Permit No: 807-0285 Type: EXJECTRICAIJ PERr.{IT Parcel No: 2101- 064 - 03 00 - 1 Site Addregs: 521 E IJIONSHEiAD CR VAIIJ I.OCA!iON : VAII., 21 BITI.DG VAf L SPORTS RENTAIJ SHOP Total Feea: 5222.50 This Palmen!3 $222.50 Total AL,L Pmts: i222.5O Balance: 90.00 ttt*t*** * * * * * * t** * ** * * a **a* * * * **ataa** i I * * * tt I I + I *'ttt******ttttt*1.** * *t I I lra * * * ** ** | ii*r * * *** ACCOTJNT ITEM LIST: Account Code Description Current PmtE EP OO1OOOO31111OO EI.ECTRICET PERMIT FEES IfC OO1OOOO31128OO WILL CAIJL INSPECTION FEE 218.50 4.00 APPLIcArror{ wrrl Nor BE AccEprED rF rNcoMprErEq Ii"rgEiS ", - "r* E5?-\Z et E:''sill'?"J*li?ffi 75 S. tr'rontage Rd. Vall, Golorado 8165? i'a)tt o4"4af TOWN OF VAIL ELECTRICAT PERMIT APPLICATION CONTRACTOR IN FORTTIATION Eledrical Contractor: Arex Ebotttc Town of Vail Reg. No.:w-E Contact Person and Phone #' : DAu 41o-31o -5736 !-!lailAddrcsst ddqruA.pe{d AoA.corh Fax#. q70-zL.?,- 6Ioletrfl_- COMPTETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials) AMOUNT oF sQ Fr IN STRUCTURE: 3,00tC ELECTRICALVALUATIoN: $ q,b0O = As*gzrs Offie at 970-328-8640 or visit forPatel# Parel # 7to I 064 o3oo I JobName: Y2, E"$C,-/{-o ft.,oe JobAddress:t2l E. L,o*>ln^A, (e l€gal Description I Lot:Block:Filing:Subdivision: owners Name:/(4wrr x eorztt llAddress: tslz.les<Anr?n/ a; ll Phone: Engineer:Address: Pu,.n qL Cfi q7Allehone: Detailed decription of work: AdA 4 Tas.c l,shss , (amo+z h*t dn,lna pseeft, AAl" tb w,css WorkOass: New() Addition( ) Remodelff) Repair( ) TempPower( ) Other( ) WorkType: Interior (}! Exterior ( ) Both ( )Does an EHU exist at this location: Yes ( ) No ( ) TypeofBldg.: Singletamily( ) Duplo<( ) Multi-family( ) Commercial$) Restaurant( ) fther( ) No. of Existing Dwelling Unib in this building:No, of Accommodation Units in this building: Is this permit for a hot tub: Yes ( ) lrto (V) DoesaFireAlarmExist: Yes( ) No( ) llDoesaFireSprinklerSystemExist: Yes( ) No( ) I,,F **************************rr************FOR OFEICE USE ONLY******** i F:\cdev\FORMS\PERMm\Bui lding\electical_permit_U-23-2005.DOC Page 1 of 2 7rl23l20os ,*m Amendment to the 2002 N.E.C. Town of Vail Ordinance 4, Series of 2005 o Overhead services are not allowed in $e Town of Vail.o Underground services shall be in conduit (PVC) from the utility transformer to the electric meter, main disconnect switch, and to the first electrical disfibution circuit breaker panel.o The main disconnect s,witch shall b tadiily awsible, andlocated next to the meter on the exterior wall of the structure. All underground conduits are required to be inspected before back-filling the trench.o In multi-family dwelling units, no electrical wiring or feeder cables shall pass from one unit to another. Common wafls and spaces are exempLo NM Cabfe (Romex) an h u only in single and mufti-family dwellings net exceding 3 sbri*. llpe III+I annot E u*d in any bailding mixd with lype +B.E EH,I,H &S oanpnde.o Aluminum onduffitssmaller than size #8 are not permitted with the Town of Vail. TOWN OF VAIL ELECTRICAL PERMIT GUIDEUNES s All installations of exterior hot tubs or spa's require a DRB approval from planning. This application will not be accepted without a copy of the DRB approval form attached (if applicable).o If this permit is for installation of an exterior hot tub or spa on a new elevated platform or deck over 30" above grade, you must also obtain a building permit. o If this permit is for installation of an exterior hot tub or spa on any existing deck or elevated platform, a structural engineer must review the existing condition and veriry that it will support the added concentrated load. Please provide a copy of the structural engineers wet stamped letter or drawing with this application.s If this is a remodel in a multFfamily building with a homeowners association, a letter of permission from the association is required.o If this permit is for a commercial space, two (2) sets of stamped drawings are required. Elatrical one-line and panel schedules are reguircd if load is added or distribution is alhrcd. I have read and understand the above. Signature Date Signed If you have any questions regarding the above information or have additional questions, please contact the Town of Vail Electrical Inspector at970-479-2147. The inspector can be reached on Monday thru Friday mornings betrueen the hours of 8am and gam. You may also leave a voice mail and the inspector will call you back. F: \cde,v\FoRMS\PERMtTS\Building\electicalJcermit-11-23-2005. DOC Page 2 of 2 LLl23l2A05 TOWN OF VAIL DEPARTMENT OF COMMI.JNIry DEVELOPMENT 75 S.FRONTAGEROAD vArL, co 81657 970-479-2t38 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALTCOMMBUILDPERMT Permit # 807-0273 Project # PRJ07-0406 Job Address: 521 E LIONSHEAD CR VAIL Status . . . : ISSUED Location.......: VAIL 2l BLDG-BREEZE SKI RENTAL Applied .. . : 08/2212007 Parcel No....: 210106403001 Issued.. ': 10n9/2007 Expires.....: 04/2612008 owNER EREMTA, SORIN - VANHOLTEN, 508/22/2007 HAWKSI,EY, CI-,EMENT]NA W. -TRUSTEE ].572 iIESSAMYN CT RIVERSIDE cA 92506 APPTJTCANT McBoYD BUfLDERS rNc 08/22/2007 Phone: 328-5789 PO BOX 238 EAGLE co 81531 I-,icense z 776-B CONTRACTOR MCBOYD BUILDERS INC OE/22/2O07 PhONC: 328-5789 PO BOX 238 EAGLE co 8r.631 License z 776-B Desciption: BREEZE SKI RENTALS INTERIOR TENANT FINISH Occupancy: M Type Construction: I-B Valuation: $89,000.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 l**|'.,l'|++|'.t|li*|t|:t*|'}t|t'}|*'|.*t**t***tlt.|*||*.*|lt.|*.|.|.*.**l|* Building-> 9916 . zs Restuannt Plan Review--> 9o . oo Total Calculeted Fees-> 91, s15 . 64 plan Check--> S59S. g9 Recre€tion Fee----> So. oo Addilional Fees----> $0.00 Investigation-> $o.oo TOTAL FEES-------> $1,s1.s.54 Total Permit Fe€----> 91,s15.54 Will Call---> $3.00 Paymenls----------> $1,515.54 BALANCE DUE___> 90.00 Approvals;Item: 05100 BUII-,DING DEPARTMENT o9/!7/2oo7 cgunion Action: AP IEem: 05400 PLANNING DEPARTMENT o8/24/2oo7 warren Action: CoND Item: 05500 FIRE DEPARTMENT Item: 05500 PUBLIC WORKS oe/0s/2o07 Ek Action: NA raaattatatttatttttatlaatttitttttttlttltttttttttttalltttttattttatttttttttttlttttttttttarttttttttl*tta*atatarl:lll+llttlllilallllllaltlllla|llttltlll See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in firll the information required, completed an accurate plot plan, and state that all the information as requircd is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build ftis structure according to the towns zoning and suMivision codes, design review approved, tntemational Building and Resideptial Codes and other ordinances of the Town applicable thereto. REQUESIS FIOR INSPECTION SHALL BD MAIDE TWENTY-FOUR IIOIru IN OR AT OUR OFFICE mOM 8:00 AM. 4 pM,+ TI,.'RE OF OR CONTRACTOR FOR HIMSELF AND OWNEN {.*.{.,f*.|.,}.l.'N.'t**+,}***********,}'t'********{.**t}***:t,}*,t.*,{.'t******ti*'f,t*,.**'i*****{.:ti****'i*!t,t.*********** CONDITIONS OF APPROVAL Permit #: 807-0273 as of 10-29-2007 Status: ISSLIED *,i *,t 't*'t*d('id.'t'l**************l'***,****:i****,t********,t******i.**********************,*t**,1**,f *:l * +*,f *'t******'|*+ Permit Type: ADD/ALT COMM BUILD PERMT Applied: 08122/2007 Applicant: MCBOYD BUILDERS INC Issued: 10/29/2007 328-5789 To ExPire: 04/26/2008 Job Address: 521 E LIONSHEAD CR VAIL Location: VAD-21 BLDG-BREEZE SKI RENTAL Parcel No: 210106403001 Description: BREEZE SKI RENTALS INTERIOR TENANT FINISH +*** *,t***'t****'l{.*,t******************t*********'lconditions.{.*.{.,}{''r{.{.*+*********'}*****,}****'t*,1.+**r.t ,r l.:r {. * ,r 't * rt {. Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond:CON0009253 The applicant shall construct all new and ensure that all existing partition walls to be used to display graphics are minimum of 3 feet from the exterior window systems so that items displayed on the walls will not count towards the allowable signage for the business. Cond: l4 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL, 't * ***{i***'ti't't {i * ****:t*'l*'** 'l | '**{'{'{'**'t'l *'t'l*{.{.************************l*+*1.1.*'********1.****t****** TOWN OF VAIL. COLORADO Statement {i {i {'**!** '+ ** * * * {.:t***'tt' {. {' {i 't {. * 't{i** * * ** * 't *'i * * '* * * * * 'l * * * .l * l. * * * * * * * + * * * * * * * * * * * * * * * * 't * * * * I * l. l. l. * f * * * * Statement Number: RO7OO0233? Amount: $1,515.64 tO/29/200709:07 Al4 Payment Method: Check Init: LC Notation; # 15 31/ fricke design build inc PETMit NO : BO7 - 0273 TYPC : .ADD,/A].,T COMM BUIIJD PERMT Parcel No: 2101-054-0300-1 SiTe Address: 521 E I.,IONSHEAD CR VAIL LocaEion; vAfIJ 21 BLDG-BREEZE SKI RENTAL Total Fees: $1, 5I5.64 This PaymenE: $1,515.64 Tolal ALIJ Pmts: $L,515.64 Balance: S0.00 f ***********'t **:t'|********+**:****************************l.****,l****{.******,t*'i'l:l:l:}**t********* ACCOI.INT ITEM LIST: Accounc Code Description current Pmts BP OO]-OOOO31111OO BUII.DING PERMIT FEES 9L5.75 pF 001-00003112300 pr,AN cHEcK FEES 595.89 wc 00100003112800 wrlr, CALL rNsPEcrroN FEE 3.00 a t ll APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR U Project #: Bo" oe73 Build Separate VAIL B are CONTRACTOR I N FORMATION s7. ovo6 CA ng, mechanical, etc.t ffiiltrm[,17 75 S. Frontage Rd. ff:Uf$nt''1u,^-uf -':H9%s TontadFerson and Phone #'s: COMPLETE VALUATIONS FOR BUILDING PERMIT Labor & Materials BUILDING: $ELECTRICAL:$OTHER:$ PLUMBING: $MECHANICAL:$TOTAL:$ 81 , oooi oo For Parcel #Assessors Office at 970-328'8610 or visit FOR OFFICE USE ONLY Zlo 1-oL"4 -o3oo ^l JoUeOAr* 5zl €n€r uaNSHeAp c-lRcl.€' YAlt- , c-o all-51Job Name: -BNECZ.E 3K) F{ENTA L Subdivision: VA tu l' ctcxsq€nP : E&E.ntt . toAtN - '3o3 14lD o+loof5?3 f97{ 6T Dt-Fr\E{. &'LeZ v4'aravt ! 'LmrEratoa TE{cr.r' FrxrSN Fotu 6 gl4\ R€F$16u 6ToRE WorkClass: New( ) Addition( ) RemodellQ Repair( ) Demo( ) Other( ) Does an EHU exist at this location: Yes ( ) No ( )Work Type: Interior fi) Exterior ( ) Both ( ) TypeofBldg.: Singl+family( ) Two-family( ) Multi-family( ) Commercial |Q Restaurant( ) Other( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: Gas Appliances ( ) Gas Loss ( ) wood/Pe!!911-l-l /999 Gas Loss ( ) Wood/Pellet ( ) Wood Burning ( n Ut /l f,,,; --uviL- 2t07 *VAIL ,-lc: 1F,tl OF €Vl/iltl-l ill F:\cdsAFORMS\PermiE\Building\buildingJermiL4-u-2007.DOC Proairco, Inc. P.O. 8ox 179 wHrAr RrDGt. cO 80034-01 79 (303) 4s8-0264 June 6,2OO7 Mr. ScoU Fricke Fricke Design/Buil4 Inc. 3829 Raleigh St. Denver, CO 80212 Re: Sampling for asbestos in a small raail shop. Location: Breeze Ski Rental 492 E. Lionshead Circle Vail, CO Sampling locations: On 6-3-07 scientist John Taylor took building material samples inside the retail sporting goods shop. The following samples were taken: 492-l Ceiling tile, N.W. storeroom" S. side of ceiling over doorway. 492-2 Drywall mud, N.W. storeroorq S. side ofwall, at doorway, 2' up' 492-3 Drywall, N.W. storeroorq S. side of wall, at doorway, 2'up. 492-4 Ceiling tile, N.W. storeroom, N.E. area of ceiling. 492-5 Wall texture, N.W. storeroom, E. wall, N. end' 5'up. 492-6 Drywall, N.W. storeroorq E. wall, N. end, 5'up. 492-7 Ceilingtile (2x4), W. showroom are4 W. end of ceiling. 492-8 Ceiling tile (2x4), lW. showroom are4 W. end of ceiling. 492-9 Ceiling tile (2x4), E. showroom are4 W- side inner wall. 492-lO Ceiling tile (2x4),E. showroom areq N.E. comer of ceiling' 492-ll Drywall, &essing roorq S. wall, below light switches. 492-12 Wall texture, hallway to old kitchen are4 W. side, 4' up. 492-13 Drywall, old kitchen ueg N.W. corner, 5'up. 492-14 Wall texture, old kitchen are4 S.E. comer' E. wall, 4'up. 4y2-15 Panel glue, old kitchen area" E. wall, S.E. comer, 5' up' 492-16 Drywall, old kitchen are4 E. wall, S.E. corner, 5' up. 492-17 Floor tile, old kitchen areg W. center room, centetr of floor. 492-18 Ceiling panel, old kitchen axea" center ofarea. 492-19 Ceiling panel, old kitchen areq S. side ofarea. 492-20 Sheet vinyl, bathroonr, W. side, at doorway. 492-21 Ceiling tile (2x4), batbroorn, center ofceiling. I Proairco, Inc. Results of lab assay: See the enclosed report from Quantem Iabs in Oklahona City' OK' Rcnrlts and Discussion: No asbestos containing materials were found in any ofthe samplec' SubmittedBy: W' lB f{.frr 'rn( Dtf'E / Oldrtfit Cry, O(Il/rn t (G,7&'7'!m' Fr (16} 755'2Go Pohrired Liglt ltrllsrorcopy Ailerior ADIrtit Rcport Clid Ploafuo' Inc' P,O. Box 179 whffiRidge,Co Em34 QuilTElUI"Sf'Io. Aoodt{imDec DieRrdwd: Recclvcd BY: Dcfnrbzcd: Atr lyadB',: l'lefrodologY: qtDTEM twg B215 06e4r?m7 Ttc€s! D€Jttrsc MMI2fIII ShollynrolcY EPiryd0O/R-gYr16 Cltuda Projoct Proj*t Loccioa Ploilct mmbcr Cotc/ Dcaqfrdoi 492E LioshcadC!tu'clo lvA N/A Ast stos ('6) No.A$lsooc ribq(96) SrqlolD C@ori6onSqlcID H@gtarorls whfrc Cciling fik WldtF' Iofua Ooryound Whfrc Sbr(tock WhXc CoililgTilc ITTiF Tattrte {r& Sffi \lhb CcilirgTitc A$csbr NotInrsl Ccllulcc Glits Fiba C€ilulos il(t & Hooogcocous#n3 g)A 4vl-t ortr m3 004 .005 1C2.2 Hoogmcous Ihgrdlotll 1924 HoDE(nlotl3 H@gmls 411.1 Hmolaous A$c8ba l,lot blcctt Asbcsor Not Plcsr' A$.610. NotPfg'cttr Arbcto! lh't Ptlscct Alblcos Noo Plts.tlt AsbsdNotM Cdluloec Cdhlos. 60 GbrsFlbcr 10 Cclluloce Ccllulc Cclluloc. Glgss Fib.r 40 {) m6 0(r7 lhl.r| o6t|In'!fr4!P6 !to$t'cddilodlbtElbn.3.!o*t,|3ftt ut$i& oo[TEMitrNvti|PE.r6dEdlEMrdPt.Mboruy0^$coe'lor9.5g|}1ltl?GtltLb|ooIyro.ftrrrcltrcicarE*o4NVLAP itndlwo"rrluooyrr-*,lte.#J.fra"t#i,5tiomrg*loJsi^ltili'ialnte r.iloa'.rtrirtrm$'oorb'!!EdD frfr"r."} fi.h#irrNitri ffif,iffi;#tiffi* Ifi ,te",sy *, bc r^rhrccd sqt b f'[' xitnt tG P{P I of 'r M" ffi H..lfO Prr Dtrn rffi GU' q<7Er?I t l&l-lfF'rfll2/ tu ({G) 7!t5ffi Polrrlmd L$ Irficromopy Arbefir Anrlye nfpert QuaTElvttabNo. Aecmt{unbcn DeRlecircd: RcaoiYcd B)': DcAnatyzod: AnabrrcdBy: Mdo&logr lsw9 9215 06n4nw TGftgaDeIa!.t oflwzw7 ShdlyBr@by pA/600/Rt3n16 Oiefr Pmrico' hc- P.O. Bot( 179 slbldRidgp C10 E0o34 Proj.ol 4nBllndtodCitclc Prioctlrcaio. IVA Wtdnbcr: MA aureu S@plaID Cli{d sqlcID ctut Dclcrifo Asbcd6(94) NooA$crtor Fib.t0r)Cqosidm H@8@tlt Whilc Cdbtl$c Clbfrc' Ooilirg Tilo w& CdliogTilF wbh sbGdt[tt wbtu Toda€ Whn' shcsEock whiF Tcdutc Affi.NotM @hb GhEs Fib.. Cclluhlc t0 30 010 m9 0lt 012 013 014 M-9 Hmt@01 19:2-l{l tlooogffirg 192.t7 Hd3t!t6 192-12 H6og.otr 4ln-B Hmo$lout 1yl:11 Homogocor A$cnorl.IdPncd Arbcaoc f,ht Prcst A$cffi Not Prlstst An.s6lihPlcslot A$cab! Not Prli.dt A6.6b.NotPrctaa Cdfthrc C.alhlocc Coltrilca CcUulola Cdluhoc fh&r .fi:th. rd4 F t!'dDi tc cddnifi of fu sr9b il rco'Pbt'b frr |DrtEit' ooTEMtet.Ntr|P$edirdTtsModn.r4bol6r'(Ijco&101959.0).lbxFtlcGol'D.t.4c|ici@6dd.NvuDicntmn ndir obr -.ryt @ -iferUOin+Ut. oolot' tli '*sr tny m lc*a o frffir:ffin t r.|fu6 @ E*dt tEF'H'6tr bfrr'ftitu P'ryt"d1 ffi" eo$ lw' Prt q|||rOlddu'|.GfU,CX 7A$rfiGltle?zn'Fa ('61 t16ff8 Pohrizcd Liglt lt{icmrcopy Ar'bcrtor Anrlynir Rcport Q0.lTEMI..bNo' li0279 AocornNrmb<r: EAIS DtreReoeivle 06fu[f2frVl Roceiv€tlBy: T![!6rDet8!tt DnsAaaBrpd. ffil0/'tffil r$r[rzcdBY $otlYBrolq ldoltoddog4 EFA/600/R'9YII6 Cli€trt Pr$o.t Prcjcct Iaontim: HtdoctNufrcc Cotor / nodptot Pmgito,Is. P.O. Bor t79 WheltRldgo,AO 80034 492 E. Llxshcad Citclc WA N/A Alb6tos (%)QtaIXM SrqlcID Cli!d Srnplc ID No-Arbc*or nbct(96)C6porftion Ydlow Madc n|th. shlttod( Tt! Floor Tilc AfuosftlorPr6Gd 0t6 017 ot5 4n-$Ilooosaodtt3 $n-16 Hmogr[oo8 0n-n tlttrcd 0l7a I^ryrrcd ,'t?'lg Hoso3@ts 19trg 49r-20 Hoqocous t-q/qcd A$cdc Not Prcscnl Asbcsas Not R'6cdt AffiNoihsct$ A$cstmtftPt6i.ot Asbrsls Not Prloort AS6Etos l.[ol PtEcat Ccllulocc Cclhlcc Cclhrl@ Ccllulosc gdlul* NA Ycllow Mtldg 018 Whfte Coiling tilc o.ry SHoct CtEd ffivryt 019 v20 u*'3 oeti* !o|!4 urm rlo*ttu eodiuo oflb 6r4b r|r $or!'rbto br |!r|!ttis' QgmlEMbr}wLAProd'tortTEMdnMhborilcry0.lb.c-odc..l0.I:9{).ItbtEForrrcbdytolt.'P.cifioh.osts6tc4NvL.q'P rctmatto odb ury o -Vrr r#J -. L;,c EiAko0rMde{2D ;; SP;60dnff tc ciot. nf; nocr nrt d bc ut'd b ffi*uocefil;*Wxft.,.iilffi#fii#tffi'tlo*-* orylott tl*.lnto.+'hfrll',t1odtu Prgc 3 dtl ffi' 2Bg fJd{p Pr'l( Uhrffi w' cr<'gr'! t (€7!6:fimrFs (llGD:r55d68 Polrrbcd lJgltMlerucopy A$crtol edydr Rcport QumIEMLabNo' ll$tll, Arordlfrlnbfi EAls Punccoivcd 0#042;WI RG€citrcd By: Tclts. Dc&tlrnr DocAslfcd. 06l04'lrffi'l AntrcdBrr ShcllYBtmlry lfceodolont: EPAltmA'Yrflr6 c|i!G Plojoct Pnjoclnccioo: Hptoalbbct: Cola / Dacrhdm Iiodrco,IE. PO.Box 179 VDcdniabe,CO t003{ 49E. LiochcdCtuoL N/A N/A A!bc*06 (%)Qun1l[l SoEIG II) Cli.nt Sd0hID C@dfm Nc.Affic Fibcr(?{,) tI/D!!d Yclorv IfrSc wliE ColingTile ASGrb! Not Ptc!.nt Cdhdotc 6{t t0(n1 ty2-21 HomFcoos A$clcrNot Prrsrqr oilnwl Cclhlm(IsFlbr Gt9 IHa dRnort U*.eait.!oad.ryana4'6'cdhofbdgs|l$oqln't'bftrildF!' Qrt[.t.&r b. NVIjP rc.rodlG.t lmt d E D{ blct(r"6cottc- lolr,o. llbnD.rttdrD' 6u b lit ?cift tu tsnlc NllLAP rccrldidor #&. ody l a1"t e.tA-ioug6&@/tt -12'co -igp /600tR-93[t6 do&' TbL 'oDo't ltt tot hG el t &h'd;Ed..; uxirei rry o6'..;ydrbuE G'd frn 'ngo o.t'rbc'ioa6 @+ it fr!' litod lb rin rngndofbbalEt. Plg. /t of4 fit coltchecksoftware version 3.4.1 t..YJ Lishtins Gompliance Certificate 2003 tEcc Reporl Date: 08/13/07 Dala filename: \\Kvafs\kvA Consulting\Projects\2007-16z\Admin\SCHEDU-1\20031E-2.CCK Section 1: Project Information Project Title: Breeze -Vail Conslruction Site: Owner/Agent: V21 Building Vail, CO 81657 D6signer/Contractor: Carl Fretrvell kVA Consulting 19590 East Main Stre€l Parfter. CO 80138 (303) 646-4770 carl@kvaconsulting.nel Section 2: General Information Building Use Description by: Prolecl Type: Bulldlng Type New Construction Retail Sales, Wholesale Showroom Section 3: Requirements Checklist Floor Area 2350 Interior Lighting: E 1. Total aclualwatts must bs less than or equal to total allowed watts. Allowed Watts Actual Watts Complies O 2. Exit signs 5 Watts or less per side. Exterior Lighting: E 3. Efiicacy greatsr lhan 45 lumens/W. ExceDtions: Specialized lighting highlighting t€atures of historic buildingsi signago; safety or security lighting; low-voltage landscaps li9htin9. Gontrols, Switching, and Wiring: E 4. Independent controls for €ach space (switch/occupancy sensor). Exceptions: Areas d€signated as sscurity or emergency areas that must be continuously illuminated. Lighting in stainvays or corridors thal ar6 olom€ntrs of the means of egress. O 5. Master switch at entry to hotel/molel guesl room. O 6. Individual dwelling units separately metered. E 7. Each spaco provid€d with a manual confol to provlde uniform light reduction by at least 50%. Exceptions: Only one luminaire in spac€; An occupant-sensing dgvice controls the area: The area is a conidor, sloreroom, rsstroom, public lobby or guest room; ryffi {/npl..-:,.sqt Page 1 of 3 Areas that us€ l€ss than 0.6 Wattysq.ff. O 8. Automatic lighting shutofi conbol in buildings larger than 5,000 sq.ft. Exepfions: Areas with only one luminalre, conldors, ator6r@ms, r€sfooms, or public lobbies. O L Photocsluastronomical tim€ s\'vltch on ext6rior lighls. Excepllons: Lighting intendod for 24 hour us6. g 10.Tandem wired one{amp and lhree{amp ballaslod luminaires (No singlelamp ballasls). Exceptions: Electronic hQh-fiequency ballasb; Luminaires on emeE€ncy cirqJits or vrith no available pair. Section 4: Gompliance Statement Conpliance Statemant: The ploposed llghfirE d€sign repr€s€nled in this document is consistent with the bullding plans, speciflcatons and other cel(xllations submited wilh lhls pemit applicaton. The prcposod lighliqg system has b€€n designed lo me€t the 2m3 IECC, Chapter 8, r€quirements in COMcheck Verslon 3.4,1 and to comply with the mandatory Equir€m€nts ln lhe Requkements Chocklisl. Carl Fretwell, P.E. Name - Ti0e Slgnatur€ Page 2 of 3 iV cotchecksoftware version 3.4.1 LIL] Lishtins Application worksheet 2003 tEcc Report Date: Data filename: \\Kvafs\kvA Consulting\Projecls\2007- 167\Admin\SCHEDU-1\20031E-2.CCK Section 1: Allowed Lighting A Power Calculation B Floor Area CDAllow6d Allowed Watts watts t fr2 Retail Sales, Wholesale Showroom 1.5 Section 2: Actual Lighting Power Calculation A Flxturs lD : Dsscrlptlon / Lamp / Wattags Per Lamp / Ballast Total Allowed Walts = BC Lamps/ #of Flxlu.e Flxturos D Flxturo Watt. E (cxD) Retall Salas, llVhololale Showroom (2350 sq.ft.l Incandescent 1: P: Pendant / Incandescent 75W HID 1: D: Downlight / Metal Halide 50W / Hybrid HID 2: T: Track Light / Metal Halide 50W / Hybrid Linear Fluorescent 1: A: 2x4 / 48" TA 32W / Eleclronic 1 1 1 2 1 61 16 75 150 25 25 25 1525 96 1536 Total Actual Watts = 3236 Section 3: Compliance Galculation lf the Total Allowed Watts minus lhe Total Actual Watts is greater lhan or equal to zero, the building compli€s. Total Allowed Watts = Tolal Actual Watts = Pmisct Compliance = JCZJ 3236 249 trfe_% U23s -;uli ,##i$r Page 3 of 3 Town of Vail Building Department To Whom it May Concern: This letter authorizes the transfer of the rights and responsibilities of the Building Permit for the Breeze Ski Rental store from Black Duck Builders to McBoyd Construction. 71b b Chris Steinke President Black Duck Builders