Loading...
HomeMy WebLinkAboutWEST DAY SUBDIVISION LOT 3 GORE CREEK PLACE GRADING & LANDSCAPE & TUNNELfflorcvs t.rosh 1-;.1 tot C."reCcceE P\4q. C.raa\. nl , Lancl ..o*p" i Turrrrel o COMMUMTYTOWNOFVAIL 75 S.FRONTAGEROAD vArL, co 81657 970479-2138 DEPARTMENTOF DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON TOBSITE AT ALL TIMES ADD/ALTCOMMBUILDPERMT Permit #:804-0101 Job Address: GQ-IJ C''--a-Q'12-c-&'\*--lt'l-o atus . . . : ISSUED Location.......: 790 WEST LIONSHEAD CIRCLE Applied . . : 0S/OZ/2004 ParcelNo....: 21D7072070fl2 Issued...: OS/7?/ZOCF^ Irroject No . : O. Oq - blgq Expires . . .: 71/75/Z0M 1 I \ | vrr I owNER VArrJ CoRp \r 05/07/2004 phone: PO BOX 7 VAIL co 81558 Licenee: CoNTRACTOR B & B EXCA\rATING, INC. 05/07/2004 phone: 97}-926-33]-t P.O. Box 1?29 Edwards, CO 81632 Lricenee: 110 -X APPLICAUT B & B EXCAVATING, INC. OS/07/2o04 phone: 9.70-925-33aL P-O. Box U29 Edwards, CO 8L632 l,i.cenee: l_10-X Desciption: LANDSCAPE ANDGRADING PLANFOR T}IE WEST DAY LOT Occupancy: Type Construction: TypeOccupancy: ?? Valuation: $33,000.00 Fireplace Information: Restricted: AddSoFr 0 Wood pellet; 0.tnr+r*.r****n*****rffi*rrdfrrrhffiffir*r*ff*r**i**.**r+r*r fEE-Si_lVtrtenV # ofGas Appliancee: 0 f ofGas Logs: 0 # of Building-; 94 72 . O 5 Restuarant plan Review-> Plan Check--> S306 .83 DRB Fee-> S0 . 00 Total Calculated Fees-> S?81 . gg 50.00 AdditionalFees--->90 .00 $0 ' 00 Total Permit Fee--> S?81. 88 90.00 Payments.--------1 $?81.88 lnvestigation-> Will CaU--> $0. 00 Recreation Fee--------> 93 . O0 Clean-up Depmit-_._> TOTAL FEE$_--> Sz81. sB BAL{NCE DUrE-> So , O0 **ffi r*rrtrrrl**r*ft t*r***attfi r*{r.}r+rf ttr***,t*rffi rfl r*ffi fr Approvals:Ide'm: 05100 BUIITDING DEPARTMENT os/L8/2OO4 CDAVTS Action: Ap SuBJECT TO CONFORMANCE TO AP CHAPTER 33 IEem: O5400 PLANNING DEPARTI{ENT 05/L9/2O04 ceorge Action: Ap Item: 05500 PITBLIC WORKS 0s/78/20O4 LBplan required. at*H*tr*H#ltttih$i!ffi ir*ffi hr*tta.lrHri|srtfi rErh*it{il*r|**fr *arH Item: 05500 FIRE DEPARrMENTO See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with dl Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Buitding Code and other ordinances of the Town aiplicable thereto. REQI,JESIS FOR INSPECTION SFIALL BE MADE TWENTY-FOIJ"R HOTJRS IN 4 PM. SIGNATURE OF OWNER OR CONTRACTOR HIMSELFANDOWNEF Action: AP Traffic Control o *{**@ CONDITIONgOFAPPROVAL Permit#: BO4{101 asof 05_19_2004 Status: ISSUED *ffi t**ffi *f ******f *r****rf ***ffi PermitType: ADD/ALTCOMMBUILDPERMT Applied: 0s/07/2oC/_Applicanr B&BEXCAVATTNG,INC. Issuedr OE/tg/2C[497U92693t7 ToExpire: 77/75/2M Job Address: Location: 790 WEST LIONSHEAD CIRCLE ParcelNo: 2tmW20TW2 Description: LANDSCAPEAND GRADING PLANFORTFM WEST DAYLOT Conditions: Cond:12 (BLDG.): FIELD INSPECTIONSARE REeIJIRED TO CHECKFOR CODE COMPLTANCE. mmt0Futn 75 S. Frontage Rd. Vail. Colorado 81657 APPLlcArloN wlLL Nor BE AccEPTED lF lNcoMPLErt-?*i|,"'"R.1O V-OfB I Permit #: nical, etc.l COMPLETE V FOR BUILDING PERMIT & Materials oR oFFlcE usE oNLY..r*r*r*r***i*t.tttr*tt*r**r*r**t**rrt RECEIVED CONTRACTOR INFORMATION Contac{ and Phone #s: l(_-(a len T 1zL,-"lffi"fl*Hl*$ {,-,, r^r . Town of Vail Reg. No.: Email address: OTHER:$ 39BUILDING: $ TOTAL: $PLUMBING: $MECHANICAL: $ For Parcel # Contact Assessors Office at 970-328-8640 or visit Aalolzo?alL JobAddress: HO Woe+ h*,st"od AE{<. AddressiPo . 6ox cl? Work Class: New( ) Addition ( ) Remodel ( ) Repair( ) Demo( ) Other Does an EHU exist at this locationT ( ) No( )WorkType: Interior( ) Exterior(y) Both()///A Type of Bldg.: Singlo-family ( ) Two-tumily ( ) Multi-tumily ( ) Commercial ( ) Restaurant ( ) Ober 6<, No. of Accommodation Units inlhisbuildine: y'//No. of Existing Dwelling Units in this buildinS. y/1) No/Tvoe of Fireplaces Existinq: Gas GasLoos( ) Wood/Pellet ( ) Wood B Gas Loos ( ) Wood/Pellet ( ) Wood Burninq (NOT ALLOWED ( ) No( )Does a Fire Alarm Exist: Yes ( ) No ( )Does a Fire Sprinkler System F:\Usersbdev\FORMS\PERMITS\BLDGPERM.DOC o2n3t20u TOWNOFVAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970479-2t38 o?*r*rr oF coMMr.JNrt" orurrot^, NOTE; THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEWCOMMBUILDINGPERMIT Permit # 804-0193 JobAddress: Status...: ISSLIED [.ocation.....: 825 WEST FOREST ROAD Applied. . : 07/3012004 Parcel No...: 21010'1207002 Issued . . : 08130/2004 3(;5Ot( -o (31 Expires ' ': 02126/2005 owNER VArL CORP Ga\!- c-'.4.-\( Qu--x Ol t lO t ZOO+ phone : PO BOX 7 VAILco 81558 License: CONTRACTOR R.A. NEI-,SON & ASSOCIATES, IN07/30/2004 Phone: 970-949-5L52P. O. DRAWER 54OO AVON, CO 8 r_62 0 License:170-A APPLICANT R.A. NEIJSON & ASSOCIATES, IN07/30/2004 Phone: 970-949-5L52P, O. DRAWER 54OO AVON, CO 81.620License: 170-A Descipion: Town of Vail Adjusted Valuafion: $270'000.00 REMOVAL OF 3OK-4OK CY FOR I4IASS EXCAVATION OF GORE CREEK PI,ACE TI'NNEI, Occupancy Fireplace Information: Restricted: Y Type Totals. . . # of Gas Applimces: 0 Building----> 51,945. ?5 Restuarant Plan Revi€w-> Plan Check--> SL 945 ,75 DRB Fee---------_-> Factor Sq Feet Valuation $2?0, 000. 00* # ofGas Iogs: 0 # of Wood Pell€c 0 FEE SUMMARY S0. 00 Total Cslculated Fees--> S3, 894. 50 S0, 00 Additional Fees------->$0. 00 Investigation-! Will Call----> 50.00 RecreationFee--------> 53.00 ClearFupD€posit-----> S0. 00 Total Pnnit Fee-------> S3 , 894 . 50 s3,894.50 50.00 s0. 00 TOTAL FEES--------> 53, 894 . s0 BALANCE DUE------> Approvals: ILen: 05100 BUILDING DEPARTMENT 08/30/2004 cdavis Action: AP Permit good for gradinq,excavation and util on1y. No consErucbion authorized rtem: 05400 PLANNING DEPARTMENT 08/L6/2004 Warren Action: COND Planning approval of Ehis mass excavation p not include any aspecbs of the tunnel or duplex construction. The above statement include utility insEallation which will occur as a part of this permit. It.em: 05500 FrRE DEPARTMETiIT 08/25/2004 mcgee Action: AP Approval subject to submission and review o d.rawinqs on water supply / fire protection issues. ltem: 05500 PUBLIC WORKS 08/24/2004 cs Item: 05550 EIiIGTNEERING Action: AP PW approval is for excavaEion only *a*aa+*arr*l*la*a See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information requireq completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances md state laws, and to build this structure according to the towns zoning and zubdivision codes, design review aprprovd Uniform Building Code and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY 149 OR AT OLJR OF'FICE FROM 8:00 AM - 4 PM. OR CONTRACTOR FOR HIMSELF AND OWNER PAGE 2 ****:**:*'|.*:t***'l*l.!t*'}*'t:t*'t***'t't'|****:}*'t*'|'t*1t*'f*:llt|tl'l*'l*|+:}*'}'t'tf*'}*'l**'t*{t**'i*:**'}'t***'t************ CONDITIONS OF APPROVAL Permit # 804-0193 as of 08-30-2004 Status: ISSUED 't*{t'|'}*'}:t:l':t**'|*'t****!*****tl|*|i*t*'t'|*,|**{t'|*'}'|'t**,t!t|*|tt'tlt*'}'f|*|t*'t!t**:t:t'}***,|**'it'}*'}**!tt|},t|'l**** Permit Type: NEW COMM BUILDING PERMIT Applied: 0713012004 Applicanr R.A. NELSON & ASSOCIATES, INC Issued: 08130/2004 970-949-5152 To Expire: 02/26/2005 Job Address: l,ocation: 825 WEST FOREST ROAD ParcelNo: 210107207002 Description: REMOVALOF 3OK4OKCYFORMASS EXCAVATION OF GORE CREEK PLACE TUNNEL Conditions: Cond: CON0006619 Planning approval of this mass excavation pennit does not include any aspects of the tunnel or duplex constuction. The above statemeot does not include utility installation which will occur as a part of this perrnit. APPLICATION WILL NOT BEACCEPTED IF INCOMPLETE OR UNS Project #:- o(3q Bui Permit #: IJJ.WIIOFVAIL 75 S. Frontage Rd. Vail, Colorado 81657 INFORMATION For Parcel # Contact **i********t***ittr.****at:r*:r******t****FOR OFFTCE USE O N Ly*********************i*i****.********* 2b?-,Tb ECE r; l[ IVED General Contractor: ,4n y'/a-*ont Town of Vail Reg. No.: /7o *A Contact and Phone #'s: --\ar.l,t-r 3:/4i?-1{ t'1? t' z o q g Email address: """*""'sisnature: //tr / r%, COMPLETE VALUA Klo"BUrLDrNG PERMTT r & Materials BUILDING: Sf A+o, w>ELECTRICAL: $OTHER: $ PLUMBING:$MECHANICAL:$TOTAL:SfZkt, AOO Assessors Office at 970-328-8640 or visit EreK Z / O /o 7zo ?ooz_ Job Name: &'z z-ez< Q Job Address: - --82tr z,/. .tanfi;- Z>_ LesalDescription ll r-ot: B*vllerc"xt - ll riring, ll sruaiuirion, ,//ozc-us owners Namei y'/a 4----urs Address-:to ?s? .auop c-o Phon,gF. 236o ArchitecUD esi g net: t/ Z+C,Address: .t/l/62/ . /d ' +7 ZA. -iE{uaz-Phone:SaZZ?z.3EAg Engineer"r(ou?E -t /.b-;€ tt Address: ,4Uap Zn PWHL. qq. q?68 Detailed descriotion of work: flar.vuoa eF @< - ttoK 4Y , ,Gz ,zk<" Etaaao;*:t s eE 4TantL Work Class: New QQ Addition ( ) Remodel ( ) Repair ( ) Demo ( ) Other ( ) WorkType: lnterior( ) Exterior( ) Both()p/A Does an EHU exist at this location: Yes ( ) No (x) Type of Bldg.: Single-family ( ) Two-family ( ) Mutti-famity ( ) Commercial X) Restaurant ( ) Other( ) No. of Existing Dwelling Units in this building: 6 No. of Accommodation Units in this building: 4 No/Type of Fireplaces Existing: Gas Appliances ( ) GasLogs( ) Wood/Pellet ( ) Wood Burninq ( | /r//A Noffype of Fireplaces Proposed: Gas Appliances ( ) Gas Loqs ( ) Wood/pellet ( ) Wood Burninq (NOT ALLOWED) Does a Fire Alarm Exist: Yes ( ) No (>C Does a Fire Sprinkler System Exist: Yes ( ) No ( !,) F:\Users\cdev\FORI\.lS\PERMITS\BLDGPE RM.DOC 02r'03t2004 oi*rr"*, oF coMMUNrrY DEVELot*t NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TMES NEWCOMMBUILDINGPERMIT Permit # 804-0194 Job Address: Location.....: 790 WEST LIONSHEAD CIRCLE Parcel No...: 210107207002 Fg el -o rS7 OWNER VAIL CORP 0'7/30/2004 Phone: PO BOX 7 VAILco 8r_658 License: CONTRACTOR R.A. NELSON & ASSOCIATES, INO7/30/2004 Phonel. 970-949-5152P. O. DRAWER 54OO AVON, CO 8162 0 I-,icense: 170-A APPLICANT R.A. NELSON & ASSOCIATES, IN07/30/2004 Phone 970-949-5152P. O. DRAWER 54OO AVON, CO 81,620 I,icense: 17 0-A Desciption: Town of Vail Adjusted Valuation: $195,000.00 MODIFICATION OF EXISTTNG MARRIOTT PARKING STRUCTURE m^r ^ 1 ^ S0. 00 Recreation Fee--------> $3 . 00 Clean-up Deposit------> # ofGas Appliances: 0 # ofGas Logs: 0 # of wood Pellee 0 Building----> 51,525. ?5 Restuarant Plan Review--> Plan Check--> 5991.?4 DRB Fe--------->S0.00 AdditionalFces------>50. 00 TOWNOFVAIL 75 S.FRONTAGEROAD VAIL.CO 81657 970-479-2138 Occupancy Fireplace Information: Restricted: Y Investigation-> Will Call---> Onrl - otot BDtf 4t?3 Status...: ISSUED Applied. . : 07/30/2004 Issued. . : 10/11/2004 Expires. .: 05/28/2005 Factor Sq Feet Valuation s195. 000.00* S0. o0 Total Calculated Fees-> 52,560.49 50.00 Total Pesnit Fee------> 92,560.49 S0 . 00 Payments----------> 52, 560 . 49 s0.00 Approvals: Item: 05100 BUILDING DEPARTMENT 08/17/2004 cdavis Action: AP MAKE NOTE OF TYPICAL CORRECTIONS NOTED ON F IL/L6/2004 cdavis Actj-on: AP Revisions approved. Make note of red-line c lisLed on original permit set of drawings ftem: 05400 PLANNTNG DEPARTMENT TOTAL FEES-----------> 32 , 5 60 . 49 BALANCE DUE--------> 08/17 /2004 warren 1,1,/1,0/2004 WarrenItem: 05600 FrRE DEPARTMENT I0/06/2004 mcgee Item: 05500 PUBLIC WORKS 10/07 /2004 Ls tt/09/2004 7sItem: 05550 ENGINEERING and corrections required for final Fire Department stagi-ng. Chad S., Mike Mcgee to R.A Nelson, V. R. for new revisions. Action: AP Action: AP Revisions to turn-around area. Action: AP based on updated pLan 10/10/04 Action: AP Fire staging area on1y. Additional plan inf Action: AP Approved Per Chad Sa1li *'t't * *:t l.Lr.*.r *!r * *)*:l *,t * *,t a*,t *,* ** '|* t:ta'* 'l *,* '|:*,1.:t:*:i I * 'l:t ii:t,t 'l:l:t I * ***,1:l:t Itl *'r *** '|'* * * 'l*{.1* **'r *.rt * See page 2 of this Document for any f*Ooo, that may apply to An. p"r.it. O DECLARATIONS I hereby acknowledge that I have read this application, filled out in frrll the information required, completed an accurate plot plan, and state that all the infonhation as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this stucture according to the towns zojing and zubdivision codes, design review approved, Uniform Building Code and other ordinances of the Town applicable thergto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR E AT 479-2149 AT OLJR OFFICE FROM 8:00 AM - 4 PM. OWNER PACE2 ***'t*'|:|{.:t!t*'|*'t'8{.,i*'}1.*!t**'t*,8'i*'t*'|'t*'**!t:|t*tl,**|'t*'t*'t*'|'t*****'tt|'t*:tf|'ti't*'t't*'t,|:********* CONDITIONS OFAPPROVAL Permit # 804-0194 as of 12-02-2004 Status: ISStIED ****'****'}*t't'f*!s*{'**'}**'}'t*'i*'i*'|''|t*'|t**'**'t*|'tt*!i*it*'|''t*!**'t*{t**'tt}!**'t**'t*'|t*'***'t+'f********** Permit Type: NEW COMM BLDDING PERMIT Applicant RA. NELSON & ASSOCIATES,INC 970-949-5152 Job Address: Location: 790 WEST LIONSIIEAD CIRCLE ParcelNo: 210107207002 Description: MODIFICATION OF EXISTING MARRIOTT PARKING STRUCTLIRE Conditions: Applied: 07/30/2004 Issued: l0/ll/2004 To Expire: 0512812005 AppLrcA'oN wrLL Nor BE AccEprE:fl.'*"o";:T,:,?liJilfiIWg-0/ f q Bqonru t-E NEVqO b. s70'-47e-214e (rnspectiolts) REVISION TO TOWN OF VAIL BUILDING PERMIT 75 S. Frontage Rd. Vail. Colorado 81657 ****rr***+***',.r*r.*************RoUTING INFORMATION FOR OFFICE USE ONLY*****rrr:rr*t*********t********** PLANNING DEPARTMENT: CONTRACTOR I N FORMATION General Contractor: ,;:R l/=zso tr Town of Vail Reg. No.: Ee4,-olff Contact and Phone #ts: j-o4u Sr.*'?Ft ??/. zogq ATTENTION: JR, CHARL|E, GREC, DORIS L?6 - Jt Contractor Signature:ltr,f% COMPLETE REVISED S FOR PERMIT {Labor & MaterialsVALUA REVISEO AMOUNT: $ELECTRICAL: $OTHER: $ r PLUMBING: $MECHANICAL: $REVISED TOTAL: $ .'<') For Parcel # Contact Eaqle County Assessors Office at 970-328-8640 or visit wvrw.eaqle-cottntv.com Job Name. -r/,/'/n,zzrozT )AA<rle 4 Tzuc) Job Address:7ts' /). #^'- <-zz- Legal Description Lot:Block:Filing:Subdivision: Owners Name L,/lry Address:Dhnna'' "-'%br^ 7-=6q Arch itecUDesioner:- qZ4O Address:Phone:3 oz' z4z . B3qa Engineer: -rr/ar*=. ,l/,-nrq r,- ll Address:Phone:. REASON FOR REVISIONS: BUILDING DEPARTMENT: Clwindows\Oesktop\DFLORES INFo\Revised Btdg permit.doc 10t1612042 TOWN OF VAIL 75 S.FRONTAGEROAD vArL, co 81657 970-479-2138 o"Q*rr"*r oF coMMLrNrry DEvELot"*t NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW COMM BUILDING PERMIT Permit # 804-0194 JobAddress: Status...: ISSUED Location.....: 790 WEST LIONSHEAD CIRCLE Applied . . : 0713012004 Parcel No...: 210107207002 ke..e, ck_'Qp-ait --r,-."-A Issued . . : 1011112004 ?ftsoc1-6, 51 Expires' ': o4/09/200s OWNER VAIL CORP 07/30/2004 Phone: PO BOX 7 VAILco 81658 License: CONTRACTOR R.A. NELSON & ASSOCIATES, IN07/30/2004 Phone: 970-949-5L52 P. O. DRAWER 54OO AVON. CO 8L620 License:170-A APPLICANT R.A. NEITSON & ASSOCIATES, IN07/30/2004 Phone: 970-949-5152P. O. DRAWER 54OO AVON, CO 8162 0License: 170-A Desciption: Town of Vail Adjusted Valuation: $195,000.00 MODIFTCATION OF EXISTTNG MARRIOTT PARKING STRUCTURE n/..,rrnrn.'\/ Fheplace Information: Restricted: Y Tlpe Totals . . . # ofGas Appliances: 0 # ofGas togs: 0 *)a*:ra:**r.,*'r**:r.***,ra:***:r**:*rr.**:rrr"r**'.r.:**:r**:r*r'r**r.i*:r*rrr*:r**'r*rtrtr*'tr FEE SUMMARY tr*,4,r*:rt*'r,at*:1.:tr':r*r* 08/11 /2004 cdavisItem: 05400 PLANNING DEPARTMENT 08/17 /2004 Warren Itern: 05600 FIRE DEPARTMENT L0/06/2004 mcgee Item: 05500 PUBI-,IC WORKS I0/01 /20O4 Ls Factor Sq Feet Valuation $195, 000 . 00* # of Wood Pellet: 0 S0 . 00 Toial Calculated Fees--> 52 ,520 .49 Action: AP MAKE NOTE OF TYPICAL CORRECTIONS NOTED ON F Action: AP Action: AP based on updated plan 10/10/04 Action: AP Fire staging area only. Additional plan inf Building---> $1, 525. ? 5 Restuamnt Plan Review-> Plan Check--> Investigation-> Will Call---> S99I .'7 4 DRB Fee-------------> S0 . 00 Additional Fees------> S0 - 00 S0 . 0 0 Recreation Fee-----------> S0 . 00 Toral Permit Fee-.-----> 32 ' 52O .49 S3 .00 Clean-up Deposit------> S0.00 Payments-------------------> 32,52o '49 TOTAL FEES----------> 52,520.49 BALANCE DUE-------> S0'00 Approvals: Item: 051-00 BUII-,DING DEPARTMENT and corrections required for final pire Department staging. Chad S., Mike Mcgee to R.A Nefson, V. R. for new revisions. Item: 05550 ENGINEERING See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I I hereby acknowledge that I have read this application, fillcd out in full tbe iaformation require4 completed an accurate plot plan, md state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Tovm ordinmces and state laws, and to build this sfrustlre according to thetowns zoning and subdivision codes, design revien, approved Uniform Building Code and other ordinances of the Town applicable thseto. PJQTJESTS FOR INSPECIION SHALL BE MADE TWENTY-FOUR HOTJRS ORAT OLrR OFFICE FROM E:00 AM - 4 PM. .Ns-w,t FORHMSELF Al,lD OWNER PAGE2 f 'l **** 'l *t*** ***t*** f *+**'l**'*t't*{r'tt'l*+**'}***t*'t'l'ti'tl.'}*'t't'l*'t*1.**'l*****lr****t*******1.**************t***l'*** CONDITIONS OFAPPROVAL P€rDxit # B0,l-0194 as of l0-l l-200t Status: ISST ED *t**rt****t't|'**ff*t****'r*i*tl}fl'|**+i'l***t!til*flr*tt't*l**'t**tl***+**ftrt*tt***'l**tll**'l*t+*a+**+|l**:l+'l***+t . PerrritTlpe: NEWCOMMBIJILDINGPERMIT Applied: OTBODW4 Applicmt RA. NELSON & ASSOCIATES,INC Iszued: l0lll/2004970-949-5152 To Expire: 04/09nW5 Job Address: Ipcation: 790 WEST LIONSHEAD CIRCLE ParcelNo: 210107207002 Description: MODIFICATION OF HOSTING MARRIOTT PARKING STRUCTTJRE Conditions: APPLICA rroN wrLL Nor BE A..EPTED rF rNcoMPLErt-?*il',YP-<rq.LL,-3J B u i I d i n g p *r T*, - -&']E:= DEg eaffi eaAe:(i'ffs'ffr-rd6-6t MWNOFV/,TL 75 S. Frontage Rd. Vail, Colorado 81657 3Ul ired IT ,%ry"*" " *n *t"B E c E r v E rr ., j0 CTOR INFORMATION General Contractor: ,4a ,z/at=ur,t Town of Vail Reg. No.: /7o *A Contact and Phone #'s: --\zrrJ^.r S\ra-riz+ t-t?t - z.aqt? Email address: contractorsisnature: Z/tr / ra COMPLETE VALUA Kr""BUrLDrNG PERMTT & Materials BUILDING:$ / 5A UO ELECTRICAL: $ 9e Doo OTHER: $ PLUMBING:$ /{Ooo MECHANICAL:$ ,A/,A rorAl: sE t 9g oaO For Parcel # **r******r*r**********************i***FoR oFFIGE USE ONL Contact Assessors Office at 970-328-8640 or visit Hm#z / o /o 7zo ?c>oz_ JobName: &.,2 4z;2^ q;Job Address:n z{ tJ . dazz=; z>- LesalDescription ll r-ot' B*tllerocx: - llririns, llsuuai"irion' //oz.us Owners Name:he 3"*_r=Addressi^ vs? -aaop , eD phone:*!.lS-. Z36o ArchitecvDesignur, q -1"Address: .,1/ZZ/ ,,/d'.' +7: ZA - 1Y{U-EZ Phone: =a3.222.334*Engineer"t(oraE + A,h.;€Lt Address: ,4aap r,n 'VryL. qn. ?zag Detailed description of work: ,//mfae:,*:a d:- €E-,frrG- r'4nnAf ?oza-^L qZxfi)za a,-r:,-77lq.E Work Class: New( ) Addition ( ) Remodet (7Q Repair (1) Demo( ) Other ( ) Work Type: Interior ( ) Exterior (1) Both ( )Does an EHU exist at this location: Yes ( ) No (X) Type of Bldg.: Single-family ( ) Two-family ( ) Mutti-family ( ) Commerciat (r<) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this buitding: p/A No. of Accommodation Units in this building: /u/A No/Type of Fireplaqes Existing: Gas Appliances ( ) GasLogs( ) Wood/peilet ( ) Wood Burning ( ) /J/4 lloffype of Fireplaces Proposed: Gas Appliances ( ) Gas Loqs ( ) Wood/Pellet ( ) Wood Burninq (NOT ALLOWED) Does a Fire Alarm Exist: Yes ( ) No ( )Does a Fire Sprinkler System Exist: Yes ( ) No ( ) FlUsers\cdev\FORMS\PERMITS\BLDGPERM.DOC R.A.NrrsoN6l O ," -= t 4, - Qore o4oz/aa SUBJECT f ine builders JOB NAME/NO.'Sprurul Ltlt(/ P. O. Drower5400 . Avon, Colorodo 81620 . 970-949-5152 ' FAX 970'949'4379 www.ronelson.com 4l R.A.NTTSoN f ine builders O "" J*u S'rn Q,. .e/oz/o+ SUBJECT JOB NAME/NO. P. O. Drower5400 . Avon, Colorodo 81620 . 970-949-5152 ' FAX 970-949-4379 www.ronelson.com 6r 'Itz(EA^/0 P. O. Drower 5400 . Avon, Colorodo 81620 . 97U949-5152 ' FAX 970'949'4379 www.ronelson.com O ," -=' t' ]e oftozhe R.A.NrrsoN f ine builders 6l R.A.NTTSON f ine builders O ,', .-,,*u =r,rrn t E gp4p+ SUBJECT JOB NAME/NO. P. O. Drower5400 . Avon, Colorodo 81620 . 97A949-5152 . FAJ97O-949-4379 www. ro nelson.com fu.ilo.l 1 mv-- ?48 3-K i --r Il/ II N) f- ( t/L 1_ Ii:l i' I .zb'-, O/ Z; ^" 1r/- l : ^. r:.6er ,-.^ 6e' _t , I 0 Fll= H N la _l_ _: |--*='-.-- i)a.i Ul r* <1I I !- l';s I I I I rrl ;JQ-t|_---_7_--i %,"7c 1#nhev ;^Dnw /r I .IZl ",'apEi,f t', t tC{ F t,F- -\1q 'li tl{tg t47v ur,e*r'0)! L----r-i Wva{,e -t *ed L'ctP d I i I t\ 15, *H ?,d El vl ffilhilE=-l I fri-rl I ?-) 'lll rg 4;.Q.0,Q aE:: C \{ rl,il R.A.NrsoN O ,, -,' 4, n Qore oqlozhe SUBJECT builders JOB NAME/NO. 'trtzG*dto P. O. Drower5400 . Avon, Colorodo 81620 o 970-949-5152 . FAX97O949-4379 www.ronelS0n.com 4I R.A.NTTSoN f ine builders O ," -.Joqr( c.-r.{ Q* a .@/o4o* SUBJECT JOB NAME/NO. P. O. Drower 5400 . Avon, Colorodo 81620 . 970-949-5152 . FAX 970'9494379 www.ronelson.com i !I I I 4unort .t i,d.qh Wn il*u--dw7 |47 ?et w;i'i" 3 -4. -- t L I I T$ ( |, I I I L- v -71- .l zo!'"," +1-li 1i, l!ri'i li l "r a o ll= E N I I I (rl ll c| i'u)=--\)|'r- ll -. IvlIrl- I \J ,.q s%ro 7t ;Nw /t- vr (f, ..q o5 l.l tF- _\1(.F*,:oItp t^w 'ur,e*r'|{3 ( ': --' af E*\lt*at L"ctPci V,-->)qt5,'jg,s..,lF.s! sti7,r'! *'/-at- /t'I ,,/ i t'fP?YY EJ C\vtr-,)/f .,',' ls' rii l=.!re ,(et,Jry+1.tr.", (//,//z//t Ilnn tw- to eq\h\t'L : ffi)hd=l fttiitl I e 4.?.o,q' lE:: L\\t tv I I :b. a $- \r N Q N \ f, $ J R R F \: $ \ g R. .H \ \ N \ \ d s j t \ {,\ =\ts F c 0 v) \NA \o t!\\x $'$ o t\ 'dl3 \-t \$t\ir (r * sf- u\1 s \=\ o $ e( \ \-.v\\l3 \, vl \ \ $ $ as ,$ t\ R \ o o o o a 5 a - STORY INLET ELEV = 8128.9 .1 - +6t2e.6 8t2e.2!\' \tr\ \\ l-OtZ6--_1 \\ st2z)\ \\\\' \"'us T_u,rui,\\atzs.r) \\\ SCALE: 1":2O' \''*'i,,"'*),r Y;:,,, \a-et zz--f \a,2,, 812a5)/w-8r2t.9 t'tt^u \ Ittz Ett22\ \ ,ly-at2r.o nf-ar2a5 m-8tt9.6 GENERAL NOTES DATE OF ASBUILT: DECEI/BER 2. 2004. PROJECT BENCHMARK: HARN CONTROL POINT ELEVATION = A2E7.A2' (NAVD 8S). = 8114.5 ''SPRADDLE,'STORM MANHOLE RIM ELEV. = E115.7 THE PURPOSE OF THIS EXHBIT IS TO SHOW THE ASBUILT CONDITIONS IN RELATIONSH1P TO THE PROPOSED DESICN AS SHOWN ON DRAWING MR 2 (ISSUE 1B) BY ALP|NE ENGINEERING, DATED 11-01-04. INC. i-bm - I ---r,;27 w# AS-BUILT - EXHIBIT MARRIOTT DRIVEWAY TOTTN OF VAIL, EAGLE COUNTY, COLORADO LL/2312P!84 65: Ls 976513 7272o PAGE 42163 vall, golotrdo Oonvcr, Colorodo Dllloo, Colotrilo Monroe & Newell nnginrc$, Inc. Date: Novwben ltr 2004 Project lvlmiott Puking Stuctruo Altcration Wcathcr': MostlySurny Vail Rosorts Developmcat Co. PO Box 949 AvoD, CO 81520 Auu Mr. Todd Goulding Project #6285 Iocation: Vail, CO Temp:4f at 10:30 A.M. Tho prrposc of this sito visit was to observc tho fiaming for tbc parking stugture alteratims for general conformancs with tho sonstruction docrrmeob Thc foltowirrg was note& 1. At th! time of tbe sib visit, all nsw @ncrste footinp,.picrs aod walls were oompletod. Thc steel franing Srprecast doubtc tce nrpport was in piaco and the dorrblc tees wqg€ cut and removcd- Tho corrcrete slab d thc nes' eokancc !o 6e stucuro was co4lotod and the site rotaining walt adjaccnt to thc Marriott Hotol was also congrlctcd Ttp ncw retaining wall al thc *isting.south ernrauce to thc parking stucture was:oot sffic4 2. The steel ooftrmns snrypo:ting the preoast doublc tccs are ryproxinatoly 5,, eccengic on thc concrcte picrs balow and arc attaahcd to the piers wi& (g) ,/1, dilqretq aachor bolts. This coadition is sfructurally acocptable as constiusted. |lmll 'EGffi} -itrrT-r-I l[aliii.th*ff. Cd.r|.. frr-.albl-h.LkJ^dL- www. motroc-acwoll.com 70 Benchmrrk Road e suhe 201 . P -o- B(|f 1<o? . av^- .^t^- ^)^ 6<.^A LLl23t2s84 95:16 9705L37272 5. No fitthm exccptions to fto oonfuagt documonts wcrs notod. lbe dor$le tece that wcre'eut orhibitsd cracks at thc bottom of the tec lcgs on oae,l€g of cac.h of the two doublo tecs. Thc cracb ar approximetcly 6 to ? foct-loag and wcrs caued byrelaxation oftho strands as thcywcre pullcd appnroximatcly li" into tle too lop.Tht contactor was inetructad to fill tlo oracka r.rsing au gpoxy iqjcction systcm. Tho sbttctrual intcgrity of the double toos is still adoquatc to orppolt oe dcsip Loade. Tbe completcd frauring qrpcarcd to bc instatlcd in substantial confomance wi0r thc constuction documenB. PAGE AUqS /ru1 Ma* Gsc, P.E. Pnoject Eagincer Monroe &Qeweu r , A EnSlDecrs, lnc. Vl't( t orP * u3t 8r{tt 10. .*r*r- ,-----1444- o^n J,fJ3l35- cHEcXEo 6Y SCALE l&ra-r.' 52,ZC 71J'un'$ 1-, Al'tt 1 $nual 6P rO Ib ,3 Tv t 7 l'toer\ w 4t/ Turypf k "/rA sr++P€-' lortdn^ al> P.o. -t'i: - - ."1 ...1 A'. v*h'f tS z'e tg3flL o€t*L & -72*S /ouvtA rfurz (EA4L PA*n€*:fi A , ov Btc( Page 1 of I Dennis Ward From: MarkGee [mgee@monroe-newell.com] Sent Friday, October21,2QQ5 2:37 PM To: Dennis Ward Subject: GCP tunnel area well wall reinforcement Dennis: Regarding your question of the vertical epoxied rebar location shown in detail 6/S3.3 at the area well located at grids A/26.3-27 of the tunnel drawings, the vertical bars may remain at 3'from outside face of precast slab edge provided ihere are (2) #5 continuous at the top and bottom of the 3 foot high retaining walls located over the precast slab. These bars should be continuous around the corners. Please call with any queslions. MarkGee, P.E. Associate Principal Monroe & Newell Engineers, Inc. rotzLt2005 Qrr*r"r*T oF coMMU*rr" orutPMENr NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW COMM BUILDING PERMIT Permit # 804-0195 Job Address: 6z,n- k*-bPtac"- So. oo Recrcation Fee--------> g3. oo Clean-up Depmit------> OIlIINER VAIL CORP PO BOX 7 VAIIJco 815s8 'APPr-,rcAIflr R.A. IIET,SoN & AssocIATES, IN0z/3o/2oo4 phone: 97o-949-5Ls2 P. O. DRAWER 54OO AVON, CO 41620 License: 170-A CoNTR,,ACTOR R.A. IIELSON & ASSOCTATES, IN07/30/2004 Phone: 970-949-5152 P. O. DRAWER 54OO AVON, CO 8162 0 License: L70-A Desciption: Town of Vail Adjusted Valuation: 4,896,836.00 CONSTRUCTION OF CONCRETE TUNNEIJ/PARKING GAR,AGE Occupancy Type Factor Sg Feet Valuation Public Buildings Zone 3 I-FR & II-FR t82.75 24,547 54,485,964.25Totals... 24,547 54,896,835.00* Fireplacc lnformatioo: Restsicted: Y # ofGas Appliances: 0 # ofGas l,ogs: 0 # of Wood Pellet: 0 ****r.t {.********,r'l****.1*****rrt ,t*'t*'t*t'ti.*'Ft*'t{i**.}t*'t 't*'}*:t*'}*t*'t'ti!i'}t*'t*{ FEE SLJMMARY {.*'l't*:t,*'}'l*'a:i*1.:t'}'}*:l,ll.'lt}'lt*'a:l*'}*l|'}**a*||tr*l.**+,1+l'|ll'}a'i*+*al{(t|| Building--- > $19,832.80 Resturrant Plan Reyiew-> Plan check-- > S19,832.80 DRB Fe+----------> So . o0 Totrl Calorlaed Feas--> 53 9, 658 . 50 S0.00 AddiaioMl Fees----- >$0.00 TOWN OF VAIL 75 S. FRONTAGEROAD VAIL. CO 81657 nu479-2138 location.....: 790 WEST UONSHEAD CIRCLE ParcelNo...: 2l0lW2O7OA2 fri o'/ - ot31 Status...: ISSUED Applied. . : Wl30l20U Iszued. . : Ml28/2@5 Expires. .: 1012512005 S0.00 Total Permit Fee-------> $39,558.50 g0 . 00 Payments----------> $3 9, 558 . 50 $0.00 o7/30/2oo4 Investigation- > Will Call----- > TOTAL FEES----------- > S3e, 668.60 BALANCE DIJE------> Approvals: Item: 05100 BUIIJDING DEPARTMSI{T 04/28/2oos cdavis Item: 05400 PLAIINING DEPARTMENT Lo/26/2004 warren 02/28/2005 warren Action: AP Per Hougland and Assocites Review Action: DN Action: AP Item: 05600 FIRE DEPARMEti|lf tt/03/2OO4 mcgee Action: AP Approved on basis of fulfillment of agreements made Ll/02/04 ref core Creek Residences and Marriott Garage plans. Fire alarm and fire sprinkler revisions are required via permits. Ieem: 05500 PUBLIC WORKS oAction: COND Gore Creek bike path reconstructiono3/LL/zoos cs section: 3 'tasphalt, 6'r aggregate base course, stabilized sr:bgradeItem: 05550 ENGINEERING See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge thar I have read this application, filled out in firll the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with 0re information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordinances ofthe Town applicable thereto. REQIJESTS FOR INSPECTION SHALL BE MADE TWEMY-FOIJR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 '' '.,.7 PM. SI€'I(ATURE OF OWNER OR CONTRACTOR FOR HMSELF AND OWNET *****:**!**********,****'r*:F:t'f *,*******:t********'t****--l*9?----*****:**'**"!*'i*:t *:t *{.!r:t *r.*i.!r{!r.{!*:r*;r**!*****!r*,t* CONDITIONS OF APPROVAL Permit # 804-0195 as of 04-28-2005 Status: ISSUED **'t***:****'t:|.'t!*,t{.*'|*:f*:F*!t*!*{t:s***:**:**{.{.,t*****'**:t,l!t|!t't!t!***t*'}'l.|!*'}*'tt!|?t****** PermitType: NEWCOMMBLIILDINGPERMIT Applied: Wl30lz0[/. Applicant: R.A. NEISON & ASSOCIATES, INC Issued: 0/.l28l2m5970-949-5152 To Erpire: 1012512005 Job Address: location: 790 WEST LIONSHEAD CIRCLE Parcel No: 2tOlW2AWz Description: CONSTRUCTION OF CONCRETE TUNNEL/PARKING GARACE Conditions: Cond: CON000690 The applicant shall not implement the construction of tbe relocated bike path option without first having been granted approval by the Design Review Board. Desigr Review approval can take between 34 weeks for approval after submital of a complete application ad maybe more time if necessary. Cond: CON00069I The deisgn of the suMivision entry sign has not been approved by the Design Review Board. An application will need to be submitted for the design. The location, shape, and size has been approved. It can take 3-4 weeks after submital of a complete application for approval to be granted. Cond: CON0006947 The applicant shall not implement the alternative address markers which removes the light posVaddress marker from the pedestrian path without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0007082 Admintrative Modification has not been revised or signed at this Time. The rcvised AdMod shall be reviewed and siged prior to a framing inspection gqs - 23 MWNOFYAIL uired 75 S. Frontage Rd. Vail, Colorado 81657 CTOR INFORMA For Parcel # 'i********i*t***********t**,r*****r****tFOR OFFICE USE O N Ly*******r******t*********t*t*t*t***t*** APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIG Project #: (- General Contractor: ,4,a /b-*t^t Town of Vail Reg. No.: /lo *A Contact and Phone #'s: a-.rlt -r Sl^arief t-l?l - zat/? Email address: contractorsisnature: //tr / a% COMPLETE VALI ///" ,AT@fTS FoR BUILDING PERMIT r & Materials BUILDING:$ q ogl, 6g{ELECTRICAL: S/Za9,eoo OTHER: $ PLUMBING:$ 40 /, ?q)MECHANICAL: $ ZOA, Ao I rorAL:$ 4.8%, 8=6 Contact Easle Countv Assessors Office at 970-328-8640 or visitEffiZ /O /o Zzo Vctoz_ Job Name: G-'2 zz;g^ q.JobAddress:" z{ z).,62-, LesalDescription ll r-ot: Bn>llarc.x, - | ririns' ll sruaiui.ron' owners N ame: y'6; ?.--*u-r=Addressio ?s? -alop. aD Phonei *tls:. 23 6o ArchitecUDesi g n"r, r/ ^, C Address: .,4,/ZZ/ ,,td''' +)- ZA ,1>FrJuaz Phone: =o=.22?- 3344 Engineet:r(ou?E + /Lhr€rL Address: ',!aap . ro PVYL. qrz. ??6a Detailed description of work: aops7-, FoA-(suN eF z:O^-xZ-tE- -,uv,rtFs ,62- GeE aa.z- Work Class: New (() Addition ( ) Remodet ( ) Repair( ) Demo( ) Other ( ) Work Type: Interior ( ) Exterior ( ) Both (X)Ooes an EHU exist at this location: Yes ( ) No (X) Type of Bldg.: Single-family ( ) TwoJamily ( ) Multi-famity ( ) Commercial (X Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this buitding: /U/A No. of Accommodation Units in this building: ,rU/* N9/Type of Fireplaces Existing: Gas Appliances ( ) Gas Loqs ( ) Wood/Pellet ( ) Wood Burninq ( No/Type of Fireplaces Proposed: Gas Appliances ( ) Gas Loqs ( ) Wood/Pellet ( ) Wood Burnino (NOT ALLOWED) Does a Fire Alarm Exist: Yes ( ) No ( )Does a Fire Sprinkler System Exist: Yes ( ) No ( ) FlUsers\cdev\FORMS\PERM ITS\BLDGPE RM. DOC o2l03t2w4 I Vu'-rfr? e fi Vril, Cr:tr-lrlrdo Deorlr, Coler, d() Fti 3.cr. a:ol.,rxdr', ivloruoe & Newell flniiin('ct $, Ift:- June 2B, 2006 Jim Wiley 4240 Architecture 5591 Coyote Ridge Avon, C0 81620 Re: Gore Creek Place lunnel door opening concrete removal' (M&N #6285) Jim, Mike Graham with R.A. Nelson called today requesling a letter io address. the issue of *n".ut" removed trom the head and jamLof a'concrete wall opening at ihef.rorth wall of ifr* irn*f. According to Uile, appto"imately 1" of conctete was removed. This should not affect the structural integriiy bi tne watt or the header provided no rebar was exposed tonoitudinalft in the processl The ends of horizontal rebar exposed in the jamb or v#Gl reb; exposed in the head is not a concern. The door frame should be filled with iiiiuii'r" "t grout ane1. installation to provide minimum cover requirements lhal may have been cdmpromised during the removal of concrete. Please call with any questions' Very truly yours, Monroe & Newell Engineers, lnc' /^Jt Mark Gee Associate Principal 21tr6 Phfntm SPonror Th' toola|do GxPrx of Tbc Arncicrn hrfrdo of Arr"hilsdr 611) !!ttin Strecf .3ulle 7. Ftisc{}' CsrlQrado i'104'lJ (t)70) 668-5776 r FAX {9:0) (16ii-.t?ll9 o cntlil' lrisc{}Gmont$t."nrve jl con: TOWN OF VAIL 75 S. FRONTAGEROAD VAIL. CO 81657 nM79-2t38 ?"r*rr"Nr oF coMMUNrrY orut.r"*, NOTE: THIS PERMIT MUST BE POSTED ON IOBSITE AT ALL TIMES NEW COMM BLIILDINC PERMIT Permit # 804-0195 Job Address: 825 FOREST RD VAIL Status . . . : ISSUED [,ocation.....: 790 WEST LIONSHEAD CIRCLE Applied . . : O7l3Ol2W Parcel No...: 2lOlO72WW2 Issued. . : Ml28l2W5 Lcgal Description: J IR--SO e1-6(a'T Expires . .: l}l25l2[5 om{ER vArrJ eoRP 07 /30/2004 PO BOX 7 VAIIJco 81658 APPLICAI\m R.A. NEIJSON & ASSOCIATES, INo7/3O/2OO4 phone: 97O-949-5L52 P. O. DRAWER 54OO AVON, CO 8152 0 License: 170-A col{TRAcToR R.A. NEITSON & ASSOCTATES, IN07/3O/2O04 phonez 97Q-949-5L52 P. O. DRAI{ER 54OO AVOIT, CO 8152 0 License: 170-A t Desciption: C@n/-O'-'--\- Town of Vail A-djusted Valuation: 4,896,836.00 CO}ISTRUCTION OF CONCRSTE TT'NNEIJ,/PARKING GARAGE Occupancy fype Factor Sq Feet Valuation Public Buildings Zone 3 I-FR & II-FR L82.75 24,547 94,485,964.25Tota1s... 24,547 F4,896,835.00* FireDlace Inforration: Restricted: Y # ofGas Appliances: 0 # ofGas Logs: 0 # of Wood Pellet: 0 **lltliil***l{.t**'l Building---- > S19,832.80 Restuarant Plan Review-> Plan Check*- > S19,832.80 Recreation Fee-------> 50.00 Total Calculated Fees-- > S39,998.50 S0.00 Additional Fee,s-------- >$0. 00 Investigation- > 90.00 TOTAL FEES------------> 939,998.60 Total Permit Fee------> $39,998.50 Will Call---> | $3.00 Payments---------- > S39,998.50 BALANCE DUE------ >$0. 00 Approvals: ITEM: O5],OO BUIIJDING DEPARTMEIiIT 04/28/2oos Cdavis Action: AP Per Hougland and Assocites Review LL/3O/2OO5 caunion Action: AP revised plan sets approved LL/3o/os. . original rewiew performed by Hougland Associates . Item: 05400 PL,AIINING DEPARTMEMI Lo/25/2oo4 warren 02/28/2oo5 Warren 08/22/2005 warren approved by planning, IIEM: 05600 F'IRE DEPARTI'EMT LL/03/2oo4 mcg'ee Action: DN Action: AP Action: AP Revj.sions submitted on Pink paper are Action: AP Approved on basis of fulfillment of agreement.s made Lt/02/04 ref core Fire alarm gnd fire It,em: 05500 PUBLIC WORKS 03/LL/2oos ca section: 3" o Creek Re o sidences and Marriout Garage plans. sprinkler .revisions are required via permits. Act j.on: COND core Creek bike path reconstruction asphalt, 6tt aggregate base course, stabilized subgrade It,EM: 05550 EiIGINEERIIIG Ittli*ll*lilt,t+*t See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with ttre information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and otlrer ordinances oftlre Town applicable thereto. RIQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOLJR HOURS IN ADVANCE Y TEI"EPHONE AT 479-2149 OR AT OIJR OFFICE FROM 8:00 AM - 4 PM' 4 OR CONTRACTOR HIMSELF AND OWNEF PAGE 2 *,|.*'|.*{.*:t*:f*:*,t{.!N.!t*******:**:*********x.,t*,**{!!t.************1.:t{.**,**:f***:F******************,**lt*****{.,t.*,.{.**'N.**** ,' CONDITIONS OF APPROVAL Permit # 804-0195 u of 12-07-2A05 Status: ISSUED ,t*'t,t*****'f *****rf ** *,* 'lr!t {.!* ** * * * * ** *:F *:* * '* {.,* ** *rf *'t***,t *x.:t*****!t*:t *1.**********,*:F!t*:t:*:*******.**{.*******:f *:irt:t*:t* Permit Tlpe: NEW COMM BLIILDING PERMIT Applied: A7l3Ol20{)/. Applicant: R.A. NEI-SON & ASSOCIATES, INC Issued: o4.l28l20[,5 970-949-5152 To Expire: L0l25l2W5 Job Address: 825 FOREST RD VAIL Location: 790 WEST LIONSHEAD CIRCLE Parcel No: 21010720fl0f,2 Description: CONSTRUCTION OF CONCRETE TUNNEL/PARKING GARAGE Conditions: Cond: CON0006920 The applicant shall not implement the construction of the relocated bike path option without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0fi)6921 The deisgn of the suMivition entry sign has not been approved by the Design Review Board. An application will need to be submined for the design. The location, shape, and size has been approved. It can take 3-4 weeks after zubmital of a complete application for approval to be granted. Cond: CON0006947 The applicant shall not implement the altemative address markers whiclr removes the light post/address marker from the pedestrian path without first having been granted approval by the Design Review Board. Design Review approval can take between 34 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0007082 Adminnative Modification has not been revised or signed at this Time. The revised AdMod shall be reviewed and siged prior fo a framing inspection REVISION TO T VAIL BUILDI RMIT Separate Permits are required for electrical, plumbing, mechanical, etc.! ll Qr 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION Contact and Phone #'s: ,il;fe Colhherfsort '471- Zolll General Contractor: A //s,,lsort Town of Vail Reg. No.:t70 -A ATTENTION: J& CHARLIE, GREG, DORIS ELECTRICAL: $ OREVISED AMOUNT: $ O REVISED rOTAL: $ C)MECHANICAL:$ O COMPLETE R EVALUATIONS FOR BUILDING PERMIT & Materials FOR OFFICE USE ONLY*ii*t**t*****************r*:r*:rrH**f* For Parcel # Contact Assessors Otrice at 970-328-8640 or visit 2l0l O 72o70oL JobAddress: BZt W. Fo.-sf Rp.Job Name: Oo"e C reek Pl ace Subdivision: 7l/ 6 rg VS enone: flt/{ _ Z 16 O Address: 1n2, lgt' s*. zoa Denr'er Phone: to, -2rz -33s Ensineer: lglo nrc{- + /l/ehJe\ REASON FOR REVISIONS:6lar;{i workClass: tlewp{ Addition( ) Remodel ( ) Repair( ) Demo( ) other( ) Does an EHU exist at this location: Yes ( ) No (4Work Type: Interior ( ) Exterior ( ) Both ( Type of Bfdg.: Single-family ( ) Twefamily ( ) Multi-family ( ) Commercial ( ) Restaurant( ) Other Qt{ No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: : Gas Apoliances (A) Gas Loqs (o) Wood/Pellet (0 ) Wood Burning ( a Gas Loqs (r) Wood/Pellet (/) Wood Burnins (NOT ALLOWED Does a Fire Sprinkler System Exist: Yes ( y[ No ( )Does a Fire Alarm Exist: Yes (yf No ( ) \Wail\data\cdev\FORMS\PERMITS\Revised Bldg permit.doc 03/r3/2003 Queslions? Callthe Building t ", 47g-2g25 Perm it Submittal Checklist Department of Community Development proj ect N a m e : (So re- - -er*k - -?-/e Le- - - - - Proj ect Add ress: - - - -2 !- 5- - - -A.Forc sr Road 0 0 0 This Checklist must be comoleted before a Buildino Permit aPPliation is acceoted. Al pages of application is complete Has DRB approval obtained (if required) Rovide a copy of approval form Oondominium Association letter of approval attacfred if project is a Multi-Family complex @mplete site plan submitted (4) Rrblic Way Fermit application induded if applicable (refer to Rtblic Works checklist) Saging plan (4) induded (refer to R.rblic Works checklist) No dumoster.oarkino or material sloraoe allowed on roadwavs and shoulders without written aooroval Asbestos teS and re$rlts sribmitted if demolition is ocanrring Architect stamp and signature (All Commercial and Multi family) Full floor plans induding building sedions and elevation{4 sets of plans for Multi-Family and Oommercial) Wndow and door schedule Full strudural planq induding design criteria (ie.loads) $ructural Engineer stamp and signature on structural plans (All Oommercial and Multi Family) Soils Report must be submitted prior to footing inspection Fire resistive assemblies specified and penetrations indicated 9noke detec{ors shown on plans Types and quantity of fireplaces shown Applicant's Signature: Date of submittal: \vaiMata\cdev\FoRMs\PERMITs\Revised Bhg permit.doc Received By: 03/13/2003 TOWN OF VAIL 75 S. FRONTAGEROAD VAIL, CO 81657 970-479-2138 Qrnoor"ENr oF coMMUNrrY oru?on"r", NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW COMM BUILDING PERMIT Permit # 804-0195 Job Address: 825 FOREST RD VAIL Status . . . : ISSUED Location.....: 790 WEST LIONSHEAD CIRCLE Applied . . : 0713012C[,4 Parcel No...: 2l0l072WWZ Issued . . : 0412812W5 Legal Description: -RBToC -6131 Expires. .: l0l25l20f5 owNER VArr, CORP 07/30/2004 PO BOX 7 VAII,co 816s8 APPITICA.\TT R.A. NEIJSON & ASSOCIATES, INo7/30/2004 Phone: 970-949-5L52 P. O. DRAWER 54OO AVON, CO 8l_62 0 License: l-70-A coNrRjAcToR R.A. I{EIJSON & ASSOCIATES, IN07/3O/2OO4 Phone: 97O-949-5L52 P, O. DRAWER 54OO AVON, CO 4L620 I-,icense: 170-A Desciption: Town of Vail Adjusted Valuation: 4,896,836.00 CONSTRUCTION OF CONCRETE TI'NNEIJ/PARKING GARAGE Occupancy T)pe Factor Sq Feet Valuation Pu.blic Buildings Zone 3 I-FR & II-FR L82.75 24,547 $4,485,964.25Tot,a1s... 24,547 $4,896,835.00* Fireolace Information: Resfiicted: Y # ofGas Appliances: 0 # ofcas Logs: 0 # oI Wood Pcllec 0 ***a**+*t++**+*+++||**++***+******:l*1i*l.**l.*:t***{.*+**+|*t***+**++|++*FEEsUMMARY*+***+|+*:t********l**+'{({.*****|** Building---- > $19,832.80 Resu.rarant Plan Reyiew-> Plan Check-- > S19, 832 . 80 Recreation Fee------- > Investigation- > Will Call--- > S0.00 Total Calculated Fe€s-- > 539,998.50 so. oo Additional Fees----*->94?.00 $0.00 TOTAL FEES------------ > $39,998.50 Total Permit Fee-----> 940,045.50 $3-00 Approvals: Item: 05100 BUII-,DING DEPARTMEMT 04/28/2005 Cdavis Action: AP Per Hougland and Assocites Review 1,L/30/2oo5 cgr:nion Action: AP revised plan sets approved ll/3o/o5. original review performed by Hougland Associates . Item: 05400 PLANNING DEPARTMBII Payrnents--------..- > BALANCE DUE--__. > $40,04s.50 $o .00 to/25/2oo4 warren 02/28/2oo5 warren 08/22/2oo' warren approved by plarrning. os/os/2006 WARRBT ACCESS OFF'OF Action: DN Action: AP Action: AP Revisions submitted on Pink paper are ACtiON: AP REVISIONS DATED 4-14-06 TO CHA}IGE THE wEsr FoREsr R.AD ,r tt", pEDEsrRrArr AccEss o" *f"*EEK DRrvE.rtem: 05600 FIRE DEPARTMETTI IL/O3/2OO4 mcglee Action: Ap agreements made Li-/02/04 ref core Creek Residences and Fire alarm and fire sprinkler revisionsItem: 05500 PITBIJIC WORKS 03/L7./2oos cs Action: COlitDsection: 3 "asphalt, 6" aggregfate base course, sta-bilized subgradeItem: 05550 ENGINEERING CfVIITS See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and suMivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQIJESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOIIRS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. Approved on basis of fulfillment of Marriott Garage p1ans. are required via permits . Gore Creek bike path reconstruction PAGE 2 {.*,|.*''t*,|.******:k,l.*'(*****ttt**,l.***:|.*d.*l****{.**{.*,F:t,|t*{({.******,t******1.**<:f**1.*{.,t.*{.*,&!********* CONDITIONS OF APPROVAL Permit # 804-0195 as of05-12-2006 Status: ISSUED **{.,.***d.'k*******{.{.**********,&,l,k*'F***:t.**********{.**,F{.*;|.:t**.'|.***:t,t.,8**{.!t'|.*'.*****{.*{.*{.*'|.'.**!t(!t(******** Permit Type: NEW COMM BUILDING PERMIT Applied: 0713012004 Applicant: R.A. NELSON & ASSOCIATES,INC Issued: M12812005 970-949-5152 To Expire: lO/2512C[l5 Job Address: 825 FOREST RD VAIL Location: 790 WEST LIONSHEAD CIRCLE Parcel No: 2l0lo72Wn2 Description: CONSTRUCTION OF CONCRETE TUNNEL/PARKING GARAGE Conditions: Cond: CON0006920 The applicant shall not implement the construction of the relocated bike path option without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after zubmital of a complete application and maybe more time if necessary. Cond: CON0006921 The deisgn ofthe subdivision entry sign has not been approved by the Design Review Board. An apptication will need to be submitted for the design. The location, shape, and size has been approved. It can take 3-4 weeks after submittal of a complete application for approval to be granted. Cond: CON0006947 The applicant shall not implement the alternative address markers which removes the light posVaddress marker from the pedestrian path without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0007082 Admintrative Modification has not been revised or signed at this Time. The revised AdMod shall be reviewed and siged prior to a framing inspection ++t*********'i********{t*********************++lff****++**+**:t+**************,}{.******f******** TOWNOFVAIL, COLORADO Statement*+**********+************'i+f********++*t****l***********it*******+***tf+t**+{.4*+l*********** Statement Number: R060000588 Anount: 94?.00 O5/I2/2OO5O2:49 PM Palment Method: Cash Init: DDG Notation: cash Permit No: 804-0195 Type: NEW COMM BUIIJDING PERMIT Parcel No: 2701-072-07OO-2 SiEe Addrese: 825 FOREST RD VAIIr IJocaLion: 790 WEST LIONSHEAD CIRCI,E Tota1 Fees: $40, 045.50 This Paltment.: $47.00 Total ALL, PmtE: 940,045.60Balance: $0.00**********+*****************+++****r****f****************************************+*+******** ACCOI.JNT ITEM LIST: Accor.rnt Code Description Currents Pmts PN OO1OOOO3153OOO INVESTIGATION FEE (BI,DG)47.OO TOWN OF VAIL 75 S. FRONTAGEROAD VAIL, CO 81657 970-479-2t38 Qrr*rr"NT oF coMMUNrrY o"ntr"r*, NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES NEW COMM BUILDING PERMIT Permit # B04-0195 Job Address: 825 FOREST RD VAIL Status . . . : ISSUED Location.....: 790 WFST LIONSHEAD CIRCLE Applied . . : Ul30l2N4 Parcel No...: 2l0lW2UN2 Issued . . : 04128/2W5 Irgal Description: T \<5Oq - o t 3'1 Expires . .: l0l25?m5 owNER vArL coRp 07/30/2004 PO BOX 7 VAIt co 81658 APPl,ICAlirr R.A. NEIJSON & ASSOCTATES, IN07/3O/2OO4 phone t 97O-949-5L52 P. O. DRJAWER 54OO AVON, CO 8L620 License: 170-A COMIRACTOR R.A. NELSON & ASSOCIATES, IN07/30/2004 Phone: 97O-949-5L52 P. O. DRAWER 54OO AVON, CO 8162 0 I-,icense: 170-A Desciption: Town of Vail Adjusted Valuation: 4,896,836.00 CONSTRUCTION OF CONCRETE TT'NNEI-,/PARKING GARJAGE Occupancy Type Factor Sq Feet Valuation Public Buildings Zone 3 I-FR & ]I-FR ]-82.75 24,547 #4,485,964.25Totals...24,547 $4,896,835.00* Fireplace Information: Restricted: Y # ofGas Appliances: 0 # ofGas Logs: 0 # of Wood Pellet: 0 Building---> $19,832.80 Restuarant Plan Review- >$0.00 Total Calculated Fees-- > $40,108.50 Plan Check-- > 519,832.80 Recreation Fee---*---) $0.00 Addidond Fees------> 54?-00 Investigation- > $o.oo TOTAL FEES-------------> $40,108.60 Total Pennit Fee-----> 940,155.50 Will Call--: >s3. oo Approvals: IIEM: O51OO BUILDING DEPARTMEMT O4/28/2OO5 Cdavis Action: AP Per Hougland and Assocites Review L1/3o/2oos cgunion Actsion: AP revj"sed plan sets approved 1"t/3o/o5. original rewiew performed by Hougland Associates , o5/t2/2oo5 bgunion Action: AP revised plans dated 4/L4/o5 on white sheets. Item: 05400 PIJANNING DEPARTMENI lo/26/2004 warren 02/28/2oo5 warren 08/22/2OO5 Warren approved by planning. Payments.----------- > BALANCE DUE---_-- > s40,1ss.60 $0.00 Action: DN Action: AP Action: AP Revisions submitted on Pink paper are "t 4-L4-o6 To crrANGE THE ACCESS OFF OF r WEST FOREST ROAD TN TO TIIE PEDESTRIA}T ACCESS OF GORE CREEK DRIVE.Item: 05600 FIRE DEPARTMENI lL/o3/2004 mcgee Action: AP Approved on basis of fulfitlment of agreements made LL/O2/O4 ref Gore Creek Residences and Marriott carage plans. Fire alarm and fire sprinkler revisions are requj.red via perrnits. Item: 05500 PITBIJIC WORKS 03/i.L/20os cs Actionr COND Gore Creek bike path reconstruction section: 3" asphalt, 5" aggregate base course, stabilized suJrgrade Item: 05550 EIIGINEERfNG CIVIIJS See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to conrply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Internalional Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV PM. BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF PAGE 2 *:*:l.**:t,F***1.*:F:t;&*{!****:{.*.{.:t**{.****:*{.:*:**********:f****,t(****************'F*****{.:*{.!*{.:**:*{.:**'!{!*{.+{.:*:t*:{.* CONDITIONS OF APPROVAL Permit # 804-0195 as of 05-1G2006 Status: ISSUED '.'.i.i(*********!{c'(*********'l.*******:&***'.*'t.***{.*.,&'!,l.**'F******************'t.*!t.***'F,t.'l.*{.*,t('(**1!*:t(*:r*||.:t{.*** PermitType: NEWCOMMBUILDINGPERMIT Applied: W|3O/2W Applicant: R.A. NELSON & ASSOCIATES, INC Issued: 0412812m.5970-949-5152 To Expire: l0/2512W5 Job Address: 825 FOREST RD VAIL l,ocation: 790 WEST LIONSHEAD CIRCLE Parcel No: 210107207002 Description: CONSTRUCTION OF CONCRETE TUNNEL/PARKING GARAGE Conditions: Cond: CON0006920 The applicant shall not implement the construction of the relocated bike path option without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0006921 The deisgn of the subdivision entry sign has not been approved by the Design Review Board. An application will need to be submitted for the design. The location, shape, and size has been approved. It can take 3-4 weeks after submittal of a complete application for approval to be granted. Cond: CON0006947 The applicant shall not implement the alternative address markers which removes the light post/address marker from the pedestrian path without first having been granted approval by the Design Review Board. Design Review approval can take between 3-4 weeks for approval after submittal of a complete application and maybe more time if necessary. Cond: CON0007082 Admintrative Modification has not been revised or signed at this Time. The revised AdMod shall be reviewed and siged prior to a framing inspection **************{"********:************:t!*********+t:l'a"t+*****'}*****+****+*************f*'t******** TOWN OF VAIL, COLORADO Statement+++****************++******f**t*++*******+*+t{'l'!'*****************1.**********{t****+*****++*f+ Statement Number: R060000505 Amount: $110.00 05/L6/200601 :56 PM Payment Method: Check Init: DDe Nouatsion: RA Nelson L6924 Permit, No: 804-0195 Type: NEW COMM BUIIJDING PERMIT Parcel No: 2LOl-072-07OO-2 Site Address: 825 FOREST RD VAIL Location: 790 wEsr IJroNsHEjaD crRcLE rotal Fees: g40,i.55.6o This Payment: $110.00 Total ALL Pmts: $40,155.60Balance: $0.00 ACCOTJNTITEM LIST: Account Code Description PF OO1OOOO31123OO PI,AN CHECK FEES Current Pmts 110.00 INDDPtr:NDEh]'T TtsSTING & INSPT)C'TION SERYICNS INC. t2084 VASEEN CT. CONFER,COLORADO 80l(l3 30367.1-7560 FAX 303€7.1-7560 Page NELD INSPECTION REFORT FORM INTIIAL VISUAL INSPNCTION Otr WELDING lnspector:Davld L. Sturgeon ITIS Job No. 0?1405 Date:12-9-05 &.72-72-05 Field lvlade Welds: x Shop Made Welds: _ Type of Wcld Inspected: Fillet x Groove _ Other _ Type of Corrponent (ie: column, beam, girder, moment welds, etc,) PC Connections Level or Elevation: Roof AREAS OT INSPECTION 8 of 31 and 17 of 52 Slab to Spandrel Grid Linc Location(s) encompassing the area(s) inspcctedftested:t4 | A- of Provide information re: conditions of nonconfonaance. Lnclude the O.D. item number and attach a copy No deficiencles were observed.of the O.D. List if applicable. kvel or Elevation: Root Details 29 and 42 B€am to B€am Orid Line Location(s) encompassing the area(s) inspected/tested; Grids B and C at 26 - 30 Provide information re: conditions of noncotrformance. lnclude tbe O.D. item nrmrber and attach a copy No deficiencies were observed.of the O.D. List if applicable. Level or Elevation: Roof Grid Line locatiou(s) encompassing the area(s) inspectcd/tested: Slab to Beam Provide information re: conditions of nonconformaoce. Include the O.D. item number and attrach a copy No deficiencies w€re observed.of the O.D. List if applicablc.* o INDEPDI\IDEN]'T TESTING & rNsPncTIoN SERYICES rNC.* 120&{VASEENCT. CONIFER, COLORADO 8O,(B 303-874-7560 FAX 303474-7560 Page 3 of rIELD INSPECTION RDPORT FORM IMTIAL VISUAL INSPECIION OT WELDING Inspector: David L. Sturgeon ITIS Job No. 0?r 405 Date:12-9-05 & r2-12-05 Ficld Mads Welds: X Shop Made Welds: _ Typo of Weld Inspected: Fillet X Groove _ Other Type of Component (ie: column, bearn, girder, moment welds, etc.)PC Connections Applicable Code or Statrdard: AwS' IBC snd Project standards - AREAS OF INSPECTION Level or Elevation: Roof 85 of 9-6 Grid Une t ocation(s) encompassing the arca(s) inspected/tested: PC to Wall hovide information re: conditions of nonconformance . Inolude the O.D. item number and attach a copy of the O.D. List ifapplicablo.No deficiencles were observed. Lcvel or Elevation: Roof 82 of 5-6 Plank to PC Grid Line Location(s) encompassing the area(s) inspeaed/tested:A I 27-29 Loea Provide infomation re: conditions of nonconformancc. Include thc O.D. item number and attaoh a copy of the O.D. List if applicable.No deflciencies wefe observed. Level or Elevation: Grid Line Location(s) encompassing the area(s) inspected/tested: Provide infomration re: conditions ofnonconformanoe. lnclude the O.D. item number and attach a copy of the O.D. List if applicable. INDEPENDENT TESTING & INSPECTION SERYTCES INC. l20Ed Vueen Ct Conifcr' COEIXS (303)tt+1ffi Fu (303) 67,1-7560 Page RDINSPECTIONS Type ofReinspectbn: Visual x Torque Testing Inspector:Divtd L. stq!999!- ITISJobNo. 0?1405 Dde: t.2-12'0n Lbt iterrs reirxpected, refening to tbe OD. itcm and thc original date ofreporting' Indicsted if the reinspected itetn confonns to orighal project gandards, mdified standards or b acccpted in the as- buft;DditiotL Cooditions initially found in norrconfonnance to original project standards but subsequenlty ae reviewed ann acceptea uy tte responsibh authority sball bave such acceptarrce in written form with written confrrnatirn mted on this rcport. o.D. ITEM ORIGINAL REPORT DATE ACCEPTEDBY ENGINEERINGREVIEW AS-BIJILT MODIFIED CONFORMINC TO STAI{DARDS DATE SIGNED oFr COMMENTS F-2 10-0t-05 X l2-12-0r Contrector Verified ComDletlon r-3 10-05-05 x l2*l 2-0{Contractor Verlfied a:.}mnlFtl6n IhIDEPDNDI}NT TDSTING & INSPDC'TION SERVICDS INC. t2n8{vAsEEflCT. CONIFER,COLORADO E0433 303{74-7560 FAX 30367'[-7560 Page 1 ofl OBSERVATION REPORT Client: Vail Resorts Development tTlS Job 196, 0? 1405 p66; 1 2-9-05 & I 2-I 2-05 Proiect:Gore Creek Location: Y!!t9l9t3!9 Inspectot:David L. Sturgeon This report package contains information concerning specific tests and inspections of struciural steel welding, sttuctural bolting, struclural sprayed fireproofing, and/or nondestructive testing. The specific criieria utilhed in judging the degree of conformance for each area of inspection are contained on each individual inspec{ion form. Also included may be lTtS' 'List of Outstanding Discrepancies' (O.D. Lisl). The O.D. List will be consecutively numbered for each page issued throughout the duration of the project. Each individual item listed will also b€ consecutively numbered. lf there are any questions regarding the content of this report, please feel free lo contact lTlS at your convenien@. A;@ David L. Sturgeon / tPresident (.-/' ICBO Certifi ed Inspector #1 1 38247-85 AWS QC-1 #82122691 Resident Level lll TN DDPAl\l I)$YI' TIIS'rING & IM'III]]CTI ON ftlt ltlrcns lirsc. t2084 VASEEN CT. cor{tFER, coLoRADo 80a3:t :}|l3{7il-756.0 FAX 303{7rt-7580 Prgr . r of OBSEFIVANo|{ REPORT 1119.1o5 1go. 0?t105 9.6.. 1l -!0-05 Loca'on: Yallr0ofioradoPbr.ct:Gorc Creek ln!poclor:Devld L. SturgFon Darid L. Slurgeon Preei&nt ICSO Cortffod Inepodor #t 1 38a47€s Alt'tSQg1 #,,2,u91 Rxilent Level lll Thls report p*kage coitslns hformaibn conceming sp€<'llc telb and lmp€cfione d strudural rtselweklir€, sfruclural bol&E, rfircturel rprayed fx']rpKirling. and/or nondestndiw tc.fng. The $eciic critoria utilized in jrdglng th6 d6greo of oonbrm€no for sadr area of inopedbn are containcd on oech IndMdual iffip€ction forn. Abo included may be lrls"Liit of oxstrnding DFc|€pancies' (o.D. Lid). Tho o,D. Liit w{l b€ coraecutvely- numbcr€d fbr oesh page issucd throughoul lio duraiion ol lho projeci. Esch IndMdual item lirted wtll algo be congocutfu€ly numbcrld. lf tlere.ara any qusrffom regarding the content of thts rspod. plaa$6 fool fres to contaci lTlS €t youf conv6ni6ncc. INDDPDNDEIYTTESTINGi & INpPECTTON SERYTCDS INC. 12084VASEEN CT. COl,llFER, COTORADO 80/Fil 303{7+7300 FAx 303$?.1.7560 Pagc ? of 3 rIELD TNSPBCIION N3PORT FORM IMIIAL VISI'AL TNS?ECTION OF WELI'ING lnspector: David L. Sturseon ITIS Job No. 0?I405 Dare: ! l-3-05 Field Made Welds: X gl6p Made Welds: _- Typc of Weld Inspected: Fil1e1 X Grooye _ Othe r '[1'pc of Component (ic: column, beam. girder, moment wclds, ctc.l PC Connecti ons AREAS OFINSPECTION Lcvcl or Elevaiu; f,oof P.C. / wclH ConRectlong Gtid Linc I"ocatio{r) lncoopalsing area(r) Provi& infornatiol rt: conditioos of Eonomfomumc. Inolude $€ O"D. im number ud dtach a copy of 6c O-D. List if qplicablc. stolf ls removeo. Due to $tort. the lFpectlons are delated untll such tltne as th€ Irvel or Etcvation: L€!,€l On€ I0 ot sl (8. Watl Root) Shear Walls Boof' trootlt8 and Wa|| Om l,inc f"ocatioa( " hovide inform*ion rl: conditious of mrcmfo,mrocc. Indudc thc O,D im nunbcr &|d atsch a copy ofthc O.D, List ifamlicablc, l'|c fteld w€ldlng wrs lound conformlng. Addltlonal insp€ctiong are tentatively -siheddrffi ().D. lt(,trs f-2,ftnd li''ll ll()irst)r)c I i0nsI erel or ljlevntion; lloci I ( irirl I ine l.()calion(sJ cncuntpassing tlte arcn(s) inspected/tesled: Pmvidc inforrution re: conditions of rnconformm. Incld. lbc O.D. i&m uuurbcr rnd rfiach a coplt of fhe O.D. List ifaoolicablc. Due to the srow coverlng the entire r€of, the reinsp€ctlons cottld not be conducted Reine InII}EPANI}DNTTIDSTING & INgpngfION saRvlcns INc.* {to84vAgEEilCT, coNrFE&coLoRAoo 004it3 303{7+75t0 FrJ( 30347&7580 Pagc 3 of 3 IIIELD INSPECTION RSPORT FORM INIrIAL YISUAL INSTECTION OF WETDING Inspector: I)jrvjd L. Sturgeon lTlSJobNo.0?1405 f)ate: ll-3-05 Field lviade Welds: X Shop Made Welds: Ty'pc of Weld lnspectetl: Fillet X Cyroove Other Type of Compoment (io: column, beam. girder, momcnt welds, etc.)P.fl. ('onnections HOUSB UI{IT #4 AREA$ OF INSPECTION Lcvcl or Elcvation: _Levels one and Tr,vo Steel Fremlng Grid Linc Incatiods) coconpassing thc uredr) inspcctcdfu*cd: Piovidt infffimstioo rt: conditions ofrcnoonforoa*c, Includc tte O.D. itcm nmbcr and mmh a copy oftbe O.D. Lirt if applicabtc. Tlrc structurrl framing vlswerl, one column ond ore heam, wac lound conformld?. Addi Lcvcl or Elwation: €rid Linc l$ation(s) encomparsing thc arc{s) inspccted 6ed: Provide information re: conditions of aoncoaformmcc. bchrdc lhc O.D. iteur number and sttach i copi of the O.D. List if applicable l"cvel or Llevalion: Grid l,ine l.ocationls) cncornpassing the arca(s) inspected/tcsled: Provide information re: conditions of nonconformnrct.Include thc O.D. itenr number ad athcb a copy offie O.D. Li*t if applicable. INDEPUNIDENTTESTING & I]\ISPECTION SERVICES INC. rz)&0vAsEEN cT. coNtFER, COLORADO 8043:t 30367i1-7560 FAX 303674-7560 ADDMONAL II\II()RMI.IION Inspector: _- ,Daviil,L. sturs€on I'l'lS Job No. 0? I .105 Date: Page ?ol'2 10-26-05 This form contains additioDal inspeetion infommtion not specifically covered in the prepared formats oftesting and inspections. x Additionallnforrmtion x Additional Inspections AdditiomlTe$s A reinsrrection visit was eonlucted on OJlitenrs F-2, F-3 and F-'1. O.D. item F-2 was found conforming. O.D. items F-3 and F-4 iemain outstandilig._ I1ES relocated the deficiencles and identlfied them with a paint marker with the r:orresponding. a.ssi gnerd O-IJ, nrrmber. A copy of the updated O.D. List was left with Mike Graham of R.A. Nelson INIDEPEI\IDE!1\IT TESTING & mSpncrroN snnvrcEs rNC. t208.lVASEEN CT' GONIFER, COLORADO 80,83 303-67+7560 FAX 3t3674-7560 Page 1 of -? OBSERVATION REPORT g1sng VaitR€sortrDevblopment 11lSJobNo..!!![-Date:-!!!6'Ql prcject Gore creek Tunnel tocation:_E!!:_9@ Inspector:David L. Sturgeon convenience. This report package contains information conceming specific tests and inspectiohs of struclural steel weHinj, structural bolting, structural sprayed fireproofing, and/or nondestructive testing' The specific criteria utilized in judging the degree of conformance for each area of inspection are contained on each individual inspection form. Also inctuded may be lTtS' 'List of Outstanding Discrepancies" (O.D. List). The O.D. List will be consecutively numbered for each page issued throughout the duration of the projecl. Each individual item lisled will also be consecutively numbered. lf there are any questions regarding the content of this report, please feel free to contacl lTlS at your ,L David L. Sturgeon President fCBO Ceflif'red lnspector #1 1 38247 As AWS OC-1 #82122691 Resident Level lll Il\iDIN PEN I)}lN'l' 1l'nSTI NG &, INnl)lt(yu oN nt|llvlctiift t N c. 12084 VASEEN CT. coNtFER, COLORADO 80433 303{7+7560 FAX 303€Zf-7560 Page I OBSERVATION REPORT Glientr Vail Resorts Development tTtS Job 1s. 071405 Dab. 10-14-05 Project:Gore Creek Locauon: VaiI, Colorado Inspector:David L. Sturgeon David L. Sturgeon President ICBO Certified Inspector AWS QC-1 #82122691 Resident Level lll This report package contains information conceming specific tests and inspections of structural steelwelding, struclural bolting, structural sprayed fireproofing, and/or nondestructive testing. The specific criteria utilized in judging the degree of conformance for each area of inspection are contained on each individual inspection form. Also included may bre lTlS''List of Outstanding Discrepancies'(O.D. List). The O.D. List will be consecutively numbered for each page issued throughout the duration of the project. Each individual item lisled will also be consecutively numbered- lf there are any questions regarding the content of this report, please feel free to contact lTlS at your convenience. INDEPDI\IIDEI\I'T TDSTING & INSPECIION SERVICES TNC. t2084VASEEN CT. CONIFER,COLORADO 80'83 303€7r-7560 FAX 30367rt-7560 Page 2 of 2 I'IELD INSPECTION REFORT FORM II\lIflAL YISUAL INSPECTION OT WELDING lrLspcclor: _ ltyj-lJ-I:: s1:ll$yoJl-*--** I'ItS Job No. ll-1-1!.::",----.* Dale: -"]i! l a:ll Ficld lv{ade Welds: _ _,},. " $hop Made Welds: . .. , Typc of Weld lnsp*cted: Iillet **-,-|- "" Grtrovc ---*-*-** Other 1"ype ofiComponent {ie: column. beam" girder. ntorns'nt rrtelds' etc.) ***$: kllold.9! Applicable Code or Standard: . . . ".4-Il:-tPC-,and Project l$mgfi: AREAS OFINSPECTION l,cvcl or llleyation: Roof ? of S-1 Rcinfnrcing Slt:cl Orid i-inc Localion(si encompassing the area(s) inspc'clctltcsted: - II ?i: Provide information rp: conditions of mnconforrrarpe. Include the O.D. item nunber and attach a copy of the O.D. List if applicable. The reinforcing steel was viewed. Size, splicing and placement were found eonforming. l,evel or lllevalion: Leve} Onc )tcin"pt'r'1 inn rrf ().1) T1r'ttts (irid Line Location(s) cncompa.ssing the area(s) inspccted/tesled: N/A pmviOi-ffiimiilon re: conOtd6m;f"o"c."f.."ra#. Include tlre O.D. it ^ n r*ber ad attach a copy of the O.D. List if applfoable. Reinspections of O.D. items F-2, F:,3 snll F-4 were conducted. The rework.is not yet complete.' ITIS wiu reinspect when completed. l.,cvcl or l.llevation: (ir id l.. irrc: l .ocat ion{ s) enconrplrss ing t hc aren( s ) i ns l-*ct etVte stcd : Provide information re: conditions of nonconformance. Include the O.D. item number and attach a copy ofthe O.D. List if applicable. TOWN OF VAILFIRE DEPARTMENP VAIL FIRE DEPARTMENT 75 S.FRONTAGEROAD VAIL, CO 81657 970-479:2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 825 FOREST RD VAIL [.ocation.....: GORE CREEK PLACE TUNNEL Parcel No...: zlIlWzWWz Project No : A05-0110 ISSUED r2t07t2ffi5 03t07/2006 09t03t2w6 OWNER VAIIJ CORP PO BOX 7 VAII,co 81558 APPIJICENT PATTERSON BIJBCTRIC PO BOX 358 DIIJIJON cotoRitrDo 80435 License: 715-S COMTRACTOR PATTERFON EIJECTRIC PO BOX 358 DIIJIJON colroltADo 80435 License:715-S Desciption: RLJN CONDUIT AND WIRE IN TLJNNEL Valuation: $12,8m.00 L2/o7/2oos L2/o7 /2oos Phone:97O-468-6L66 L2/07/2oos Phone 3 9'7O-468-6!66 Elcctrical--..-- > DRB Fc€----- > Investigation-- > Will Call-------> TOTAL FEES-- > Approvals: Item: 05600 FIRE DEPARI'!{ENT t2/0e/20Os mcgee FEE SI'MMARY Tohl Calculaied Fe€s- > Additional Fe$------ > Total Permit Fee---- > Paymenls--------- > BALANCE DUE..-.-.. > $0.00 90. 00 $0. 00 $0.00 $712.00 $?12.00 $0.00 s712.00 s712.00 $0.00 Action: AP CONDITIONS OF APPROVAL ECLARATIONS i I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state ttnt all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this stnrcture according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto. TELEPHONE AT 47}2135 FROM t:OO AM.5 PM. OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNEF REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADV +1+*'t**ttl*++**'i*****f'|'tt'i'i***++tl++***t*t+++++*'|*++****'i'i++****'|****+*t+ff**++ft****++ttt** TOWNOFVAIL. COLORADO Statement * * * * f 'l * **t**l+t*t******ttl++**'tf ****+ + t **+*******l'************{'{'t++*+*++ * + * + *+++ +++* * ++++*** Statenent Nunber: R060000200 Arnount: $712.00 03/07/2OO6OL:24 Pt( Payment Method: Check Init.: DDc Notation: PatteraonBlectric 5121 Permit No: A05-0110 llpe: ALARM PERMITParcel No: 2LOL-O72-O7OO-2 Site Address: 825 FOREST RD VAILLocation: GORE CREEK PIJACE TUNNEL Toual Fees: S7l2.Oo Thie Fayment: 9712.00 ToEaI AIrL Pmt6: $712.00Balance: 50.00l++++***t***i*f*+i+++++**+++***t*t****+t+f*****+**t***++*******tit++***ir*rr********++*+++*** ACCOUNT ITEM LIST: Account Code Description Current EtnEs BP OO1OOOO31111OO FIRE AIJARM PERMIT FEES PF OO1OOOO31123OO PI,AN CHECK FEBS 480.00 232 . OO 75 S. Frontage Rd. Vail, Colorado 81652 APPUCATIOT.ILL NoT BE AccEPTED IF INCOMPLE.R UNSIGN Project #: Building Permit #: Alarm Permit #: 970-4 79-273.5 (Insoections I Commercial & Rejiaential Fire Alarm shop drawings are required at time of FORMATION Fire Alarm Contractor: . is-l Iffipp1z<;a,rJ tr lec&tc Town of Vail Req. No.:l tb-9 Corllict and Phone #'s:P; 4a/- b /6b E-Mail Address:FFOZL* A ?.*rttota,t- fl o t- \YAfi $. irH ,ls]fi il AH)APTATENI trlj iit; ii li CoMPLETE VALUATTONS FOR ALARM PERMTT (nfiort$antqidr):,'.- 'a/..2* ///z (rr*/ 2.2.t /.2; 7--SS-t A llale: Fire Alarm: $ tZ tr ConEtt Asessorc Office at 97O'328-864O or visit # Parcel # too*Er" aeeL 2.s .)obAddress:rrt fral?r4 filln.( Legal Description Lot:Block: ll Filing:Subdlvisionl Owners Name: yRbC Address:Phone: Engineer: R5\Address:Phone: Detailed Localionof *ork'ffi f---i\-' e;;-V;);il'J ;;) );' ;7 +o""4.( ( T?zrzn el \ Detailed description of work: work class: ruewlf Addition ( )Remodel( ) Repair( ) Retro-fit( ) Other( ) - -t- Xo bT existing Dwelling Units in this building:ffithisbuilding: t Does a Fire Sprinkler System Exist: Yes (NoO ) Parcel !t**********!t*************rv******'t**tt***FOR OFFICE USE ON LY** * * * * rr ** Jr* * * * ** * ** *'r * * * * * ** * * * * * * ...i_._::..-. rHE-ffiiffi Dtc 0 6 2005 TOV.COM.DEV. T$VA 1tL-0712612002 ApptrcATrorOrLL Nor BE AccEprED rF rNcoMpLES* un' commercial & Residential Fire Alarm shop drawings are requirea at time of application submittaland must include information listed on therid ---^ Project #:o.t.0 r 3? Building Permit #: Alarm Permit #: -o 9 7O-4 79- 2 7 35 finspections I MVNOFWN 75 S. Frontage Rd. Vail, Colorado 81652 Fire Alarm Contractor: @1ryp1z.;ad E l".lA.Town of Vail Req. No.:l lb;t Contact and Phone #'s:,(- 4a/- b /hb E-Mail Address:frAA-A &>rzarrt*- rlot* Contractor Siqnature: t,/ - COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materiats) Fire Alarm: $ 14 tr( r.***tr**********************************FOR OFFICE USE ONLY**rr*******r.*********************:t**** Other Fees:Date Received: Public Way Permit Fee:Acceoted By: Occupancy Group: RECEIVED Otc 0 6 200s TOV.COM.DEV. Contact Assessors Office at 970-328-864O or visit for Parcel # Parcel # 2.s r Job Address: rrt Farcff4 f,il, Legal Description Lot:Block:Filing:Subdivision: Owners Name: VRbC Address:Phone: Engineer: R{h Address:Phone: DetalJed Localion of work: (i.e., floo"-W*U)*i\,| + Dt,k- n/ +*.-r"1 /lzurol e-i \ Detailed description of work: WorkClass: NewV Addition( ) Remodet( ) Repair( ) Retro-fit( ) Other( ) Typeof Bldg.: Single-family( ) Two-familyff) wulti+amily( ) Commercial( ) Restaurant( ) Other( ) No. of Existing Dwelling Units in this building:No. of Accommodation units in this building: Does a Fire Alarm Exist: Yes ( ) No (X)Does a Fire Sprinkler System Exist: Yes ( ) No C ) \wail\data\cdev\FoRMs\PERMITS\ALRMpERM. DOC 1tL-0712612002 TOWN OF VAIL FIRE DEPARTMENP VAIL FIRE DEPARTMENT 75 S. FRONTAGEROAD VAIL, CO 81657 970-479-2135 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Permit #: A06-0004 Job Address: 825 FOREST RD VAIL Status . ' . : APPROVED location.....: GORE CREEK PLACE TUNNEL Applied . . : 0ll05l2ffi6 Parcel No...: 2l0lO72O7NZ Issued . . : ProjectNo : ExPires. .: l2/26/2W6 oI,rrNER VArr, CORP 0A/05/2006 PO BOX 7 VAII-, co 81558 APPTJICANI APEX TECHNOLOGY SOLUTIONS 01-/05/2006 Phone: (303) 22L-4354 1803 EISENHOWER WICHITA KS 67209 I-,icense : 598 -S CoNTRACTOR APEX TECHNoL,oGY SOLUTIONS 0t/05/20O6 Phone: (3o3) 22L-4354 1803 EISENHOWER WICHITA KS 67209 I-,icense: 598-S Desciption: FIRE ALARM CONTROL PANEL AND TUNNEL DEVICRS Valuation: $18.852.12 FEE SUMMARY *t,**'r+aa'l'i***'t*.r:it t,:f '**:*,r:|**'**t*:a:i+:l"i:r+**'***:r*'****'t*:l'r***:**** 91, 545. 90Electrical----- > DRB Fee----- > InYestigation-- > Will Call--------- > $0.00 90 .00 s706.95 $0.00 $1, 99s . 90 $0. oo Toal Calculated Fees- > Additional Fees-----> 5350. oo Total Permit Fee----> 51,995.90 Paymenb---------- > BALANCE DUE----- >TOTALFEES--> $1,64s.90 Approvals: Item: 05500 FIRE DEPARII{ENT 0L/os/2006 mcgee Action: AP Approved as noted: 1. Revisions and change orders must follow process as developed by RiIA and agreed upon by 42/40 and ToV.2. Coordinate flow indicator with fire sprinkler contractor. Two different devices are submitted, one by each contractor. 3. Verify wiring to tamper switches in main water entry room. Plans do not reflect accurate count.4, Caution: P1ans are insufficient to give guidence in locating smoke detectors near beanns on sloped ceilings (Sheets FAL24, 1-34, L44, 7-54, L64, L74, L84) . 5. Notes from 42/40 indicate potential conflict in locating fire detection devices and fire sprinkler heads in the same location, 6. Nomenclature (FA20L) is not sufficient to reflect specific device address. Alpha descriptionsr are redundant . 7. Id location of AC breaker. 8. Specify monitoring agency and means of monitoring. 9. Plans do nots reflect garage flow switch. 10. control valves ,oQrrarrreeze loops may need a#t switches. consult with fire sprinkler contractor for final design, CONDITIONS OF APPROVAL DECLARATIONS I hereby acknowledge that I have read this application, filled out in frrll the information required, completed an accurate plot plan, and state that all ttre information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto. Rf,QUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADVANCE BY TDLEPHONE AT 479-2135 8:(X)AM-5PM. OF OWNER OR CTOR FOR HIMSELF AND OWNEF TOWN OFVAIL 75 S.FRONTAGEROAD vArL, co 81657 970-479-2138 ELECTRICAL PERMIT Job Address: lncation.....: 825 FOREST RD ParcelNo...: 210107207002 projectNo ' RR:Oq _o()1 OWNER VATL COIpo Box i' Gu^*-U'12'z^E'-4'cAN 15 /2004 VAII,co 8t_658 License: CONTRACTOR TRI PHASE EIJECTRIC 0325 HARDSCRABBLE ROAD GYPSI]M CO 8153 7 Li cense : 1- 18 -E APPI-,ICANT TRI PHASE EIJECTRIC 0325 HARDSCRABBLE ROAD GYPSI'M CO 8163 7 I-.,icense: 118-E 09 /L5/2004 Phone: 9'70-524-7L35 09/L5/2004 Phone: 910-524-7L35 of*tt* oF coMMrrNrrv oev'otnNr NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Permit #: Status. . Applied. Issued . Expires . Phone: E04-0180 $ov'o to ( .: ISSUED .: 09/15/2004 .: 09/15/2004 .: 03/1412005 Desciption: TEMP POWER FORFLJTURE OFFICE TRAILERS Valuation: $1,500.00 FEE SUMMARY Elechical-----> DRB Fee------> Investigation--> will call--> TOTAL FEES-> $50.00 s0.00 50.00 $3.00 ss3.00 s53.00 s0.00 ss3.00 s53.00 s0.00 Total C.alculat€d Fees-> Additional Fees------> Total Permit Fee-----> Palrnents----------> BALANCE DUE-_-.> Approvals: Item: 06000 ELECTRICAL DEPARTMBNT 09/L5/2004 JS Item: 05600 FIRE DEPARTMENT l:t,ltat* *a+ '},lt * Action: AP CONDITIONS OF APPROVAL Cond:12 -!?t!o--'c-;]-;-'lt-llP-.I.T;l-P-qH-9li:-.*-1--+-T9-YI*?.?.J'9-.9.'1g95.-T-9*--q;o-?-1-.9-9y-l*J-H'c-";.*'|*:*'}**'*l**:},}'*'i:},t*''***|*|** DECLARATIONS I hereby acknowtedge that I have read this application, filled out in full the inforrnation required, completed an accurate plot plan, and state that all the information as requAed is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and zubdivision codes, design review approved, Uniforrr Building Code and other ordinances of the T thereto OR AT OUR OFFICE FROM 8:00 AM - 4 PM.REQUESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADV OF OWNER ORCONTRACTORFORHMSELF AND OWNER ApplrcArroNt . no, BE AccEprED rr rn.orr.='?R uNsr Building Permit #: MMIWYAIL 75 S. Frontage Rd. Vail, Colorado 81657 0q-orA? Electrical Permit #: 97 O-479-2L49 (Inspections) RECEir,--, R INFORMATION Electrical Contractor:i,- Pl; El-,|Town ofVail Reg. No.: /tgE qonpct and Phone #'s: Jo/"^ J?d -39qs- E-Mail Adfress:14 ,/1 Contractor ryTU^L SQ. FEET FOR NEW BUITDS and VALUATIONS FOR ALL OTHERS (tabor & Materials AMOUNT OF SQ FT IN STRUCTURE:ELECTRICAL VALUATION: $ /sCz t) *************:t***j!'i**:t***********'r*****FoR oFFrcE usE oNLY**......I[dd [ .3tF.iilil;...... -2-12J I IrDA Eaac. I Aaaanlad Rrr. Other Fees:Date Received: DRB Fees:Acceoted BY: Planner Siqn-off: Contad Assessors Office at 97O-328-864O or visit for Parcel # Parcel #lo o>ooL Job Name: 6'oo C4_._L Job Address: yZf I A,r- /^; I Owners Name: /O, Detailed description of work: -kn/, f ot _cr L-<r fr-,I<rs WorkClass: New() Addtion( ) Remodel( ) Repair( ) TempPowerQQ Other( ) Does an EHU exist at this location: Yes ( ) No ( )WorkType: Interior( ) Exterior( ) Both( ) Type of Bldg.: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Accommodation Units in this building:No. of Existing Dwelling Units in this building: for a hot tub: Yes ( ) No Does a Fire Sprinkler System Exist: Yes ( ) NoDoes a Fire Alarm Exist: Yes ( ) No ( ) \WAiI\dAtA\CdCV\FORMS\PERMITS\ELECPERM. DOC 07 t26r2002 TOWN OF VAIL 75 S. FRONTAGEROAD VAIL, CO 81657 970-479-2138 OWNER VAIIJ CORP PO BOX ? VAII., co 81558 APPLICANT PATTERSON EI-,ECTRIC CO P O BOX 483 DIIJIJON co 80435 I-,icense: 208-E CONTRACTOR PATTERSON ELECTRIC CO P O BOX 483 DII-TIJONco 80435 License: 208-E os/L2/2oo5 05/t2/2oos Phone. 97o-468-6L65 05/t2/2o0s Phone z 97o-468-6'L66 EPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Permit #: E05-0073 Job Address: Status . . Location.....: 790 WEST LIONSHEAD CIRCLE-GORE CREEK RESApplied Parcel No...: 21010720/ffi2 Issued - ProjectNot -i.()c.l -r(1t Expires. ISSUED 0str2/2w5 0st13l2m5 tU09t2m5 Desciption: ELECTRICAL ROUGH AND FINISH FOR TUNNEL Valuation: $278,000.00 Electdcal----- > DRB Fee----- > Investigation-- ) Will Call-:--- > TOTAL FEES.- > 9s, 812 - 10 s0.00 $0.00 $3-00 FEE SUMMARY Total Calculated Fees-- > Additional Fees-------- > Total Permit Fee-------> Paymen$------------- > BALANCE DUE._--_-> Approvals: Item: 06000 EI-,ECTRICAI-, DBPARTMEMT 0s/12/2OOs JS Item: 05500 FIRE DEPARTMENI Action: AP CONDITIONS OF APPROVAL Cond : 1- 2 (BI-,DG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Uniform Building Code and other ordirnnces of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479.214?AT OUR OFFICE FROM 8:00 AM - 4 PM. AppLrcArroJlLL Nor BE AccEprED rr rnco'rer,t#fr"-pru oq-o,t? Buifding Permit S:3o4- CONTRACTOR INFORMATION Electrical Permit #: F,of 97 O-47 9 -2L49 (Inspections) MWNMI4 75 S. Frontage Vail, Electrical Contractor:Fir:e";; -rL+e,2 Town of Vail Reg. No.:pzoy 'oB,o4{non,u rn't' K6n r-.-4a E-Mail Addressl /942@ Elenu't,k lder contractor sisnatwetro fuJ"A) COMPLETE SQ. FEET FOR NEW BUILDS and VALUATIONS FOR AtL OTHERS (Labor & Materials) AMOUNT OF SQ FT IN STRUCTURE:45.o ELECTRICAL VALUATIoN: $ 27 Contact Assessots Office at 97O-328-864O or visit for Parcel # Parcel # rob Name: 4n- Ou./< Er,l)'-t Job Address: ^ -JD) / \fz\ t--aELe>d D t-.....-' Legal Description Lot:Block:Filingr Subdivision: owners Nu ", Va.t{ ?.V_,f llAddress:Phone: Ensineer: 2/ 11. lsr,, ll nooress:Phone: Detaileddescriptionof work: Tm/le// t()r?a_ ,Q"a_Vh _+ V)rsA, l.t) t'/WorkClass: NewQQ Addition( ) Remodel ( ) Repair( ) TempPower( ) Other( ) Work Type: Interior ( ) Exterior ( ) Both X)Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family ( ) Duplex ( ) MultFfamily ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building: @ No. of Accommodation Units in this building: Is this permit for a hot tub: Yes ( ) ruo fX) ooes i fire AtJrm l ooes a frre sprinkler system Exist: Yes ( ) ttto (,lJ ,/' A71ptfUv-U ******k*t********i******************,t**FOR OFFICE USE oNLy***rr***************:r*rr**************rt Other Fees:Date Received: DRB Fees:Acceoted Bv: Planner Siqn-off: .'y ,iBtt \\VAi I\dAIA\CdEV\FORMS\PERMITS\ELECPERM. DOC 07 t2612002 TOWN OF VAIL FIRE DEPART"'*' 75 S. FRONTAGEROAD VAIL, CO 81657 970479-2135 VAIL FIRE DEPARTMENT(D NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT PErMit #: FO5-0053 30 ul- o('( t Job Address: 825 FOREST RD VAIL Status . . . : ISSUED Location.....: GORE CREEK PARKING GARAGE Applied . . : lDll#zms Parcel No...: 2101072WC/JI2 Issued. . : 0613012006 Project No : ?RSOq -6(3l Expires . .: l2l26l2ffi6 or{NER vArrr eoRP Lo/t4/2oos PO BOX 7 VAIIJ co 81558 APPLICAIfT ALL STATE FIRE PROTECTION, TLO/1-4/2OO5 PhONC: 303-288-3901 5045 E 76TH #t2 COMMERCE CITY co 80022 License: 370-S coNrRAcToR ArrL STATE FrRE PROTECTION, TLO/L4/2O05 Phone: 303-288-3901 5045 E 76TH #t2 COMMEREE EITY co 80022 I-,icense: 370-S Desciption: GORE CREEK PARKING GARAGE-INSTALL FIRE SPRINKLER SYSTEM Valuation: $67.530.00 Mechanical-- >So. oo Restuarana Plan Review--> FEE SUMMARY :r'r'.:rr*'tr**+*ll*****r.rt:r:Fa'r*tt'i+lr:*{ri'r'r'}**r.*rtr.**'r****'*rt.t:t.t.**'*** So. o0 Total Calculated Fees--> $6,090.06 S0.00 Additional Fees-------> $2, 1?0.03 )Plan Check-- > g35o.o0 DRB Fee------------ > Investigation- > $2,8?0.03 TOTAL FEES-----> S6,090.06 Toial Permit Fee-----> S3,920.03 Will Call--- >$0.00 $3, 920 . 03 Qo ooBALANCE DUE------.- > IIEM: O51OO BUIIJDING DEPARIII{ET{T Item: 05500 FIRE DEPARl'l{Elflr Lo/26/2O05 mcgee Action: AP Garage on1y. Residential garages are under residential permits. L2/L9/2o05 Mccee L2/23/2005 mcgee Action: AP Bldg 1 and 2 revision approved. Action: AP Permit is approved as noted for revised pI' receiwed L2/2L/ 05 . L. FDC and FHV are not shown in submitt,als. 2. Flow indicator musts be located directly above FDC. 3. East I"DC location must be field verified. 4. Coordination of valve roorn layout must be resolved. 5. Fire alarm conEractor must specify flow indicator. 5. Normally closed FDC wet supply is not shown on Riser diagram. 7. Check valves, globe valves flow switch and tamper switches and antifreeze are : in su.bmittals, 8. Permission to delete heads in open stair is granted. 9. Control valves musE be accessible without special knowledge, use of keys or ladders. CONDITION OF APPROVAL Cond: 12 (BLDG.): FIEI-,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPI-,IAIiICE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and ptot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQTj,ESTS FOR INSPECTION SHALL BE MADE TWENTY.FOUR HOURS IN ADVAI\CE BY TELEPIIONE AT 479-2135 FROM 8:00 AM - 5 PM. SIGNATURE OF O CTOR FOR HIMSELF AND OWNEF o APPLICA o TION WLL f,'sOSS Project #: NKLER P TION Fire Sprinkler shop drawings are required at time of permit submiftal and must include the following. Permit application will not be accepted without this information:. A Colorado Registered Engineer's stamp or N.l.C.E.T, Level lll (min) stamp.. Equipment cut sheets of materials.r Hydrauliccalculations.. A State of Colorado Plan Registration form.. Plans must be submifted by a Registered Fire Protection Contractor. NOT BE ACCEPTED IF INCOMPLETE OR U TVWNWVAIL 75 S. Frontage Rd. Vail, Colorado 81657 COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials) Fire Sprinkter: $ l--7 F\?fi'OO for Parcel # ***************************************FOR OFFICE USE ONLY************************** *********** CONTRACTOR INFORIVIATION Contact and Phone #'s:Town of Vail Reg. No.: E-Mail Address: Contact Assessors Olftce at 970-328-8640 or visit Parcel # JobName:\96re CreeK Porkinq baraqg JobAddress: (p15 t_ronShCad ?l Legal Description ll Lot: ll Block: ll Filing:Subdivision: Owners Name: ll Address:Phone: Engineer:Address:Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) Prrr\r-irn (.rarnrrp Detailed descriptionC work: ) \n<{nll Q;.e \Drink\er <r|<{ern Wo*Class: Newfi) Addition( ) Remodel ( ) Repair( ) Retro-fit( ) Other( ) Type of Bldg.: Single-family ( ) Two-family ( ) Multi-family ( ) Commercial ( ) Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building:No. of Accommodation Units in this building: Does a Fire Alarm Exist: Yes ( ) No ( )Does a Fire Sprinkler System Exist: Yes ( ) No ( ) \Wail\data\cdev\FORMS\PERMITS\SPRKPERM.DOC 07 i2412002 TOWN OF VAIL 75 S. FRONTAGEROAD VAIL, CO 81657 970-479-2138 o ARTMENT OF COMMUMTY DEVELOPMENT o DEP NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT PErMit #: MO5-0I17 - -.t o*'D\llt MECHA 'pttu' Job Address: 790 W LIONSHEAD CR VAIL ParcelNo...: 2101072A7W2 ProjectNo t ?ri.+-otrr OWNER VAIIJ CORP So('61o1 6u+-o4,Status...: ISSUED [,ocation.....: GORE CREEK PLACE TUNNEL/PARKING Applied . . : M/W120O5 Issued. . : Wl25l2W5 Expires. .: 01121120{Jl6 06/oe/2005 PO BOX 7 VAIIJ co 81658 APPl,ICArqf MfD COIINTY PLUMBING & HEATINoS/09/2oos Phone: 970-458-4924 P. O. BOX 23L46 SIIJVERTIIORNE co 80498 L,icense: 225-t'l coNTRAeTOR MrD eolrlcfY PrilMBrNG & HEATTN06/09/2005 Phone: 970-468-4924 P. O. BOX 231.86 . SII,VERTIIORNE co 80498 License: 225-ln Desciption: GORE CREEK PLACE TUNNEL/PARKING-INSTALL ALL MECHANICAL WITH SNOWMELT Valuation: 9252.495.50 Fireplace Information: Restdct€d: Y # of Gas Ap,pliamas: 0 # ofGas Logs: 0 #of Wood Pellet: 0 **:tttirtttt,it**t*'rt'rtt'a:!*'t*r*'hrra'*a* Mechanical--> 95,050.00 Restuarent Plan Review- > PIan Check--> $1,26s.00 DRB Fee------------ > s0.00 Total calculated Fees-- > $5,328.00 $0. oo Additional Fees------ >$0.00 Inv€stigation- > Will Call----->s3.00 s6, 328 . 00 s0.00BALANCE DUE-.-_-- > {,r**tt+t++++r**** ftem: 05100 BUIL,DING DEPARTMENT 06/09/2005 JS Action: AP IIeM: 05600 FIRS DEPARTTUENI CONDITION OF APPROVAL Cond: 12 (BL,DG.): FIEL,D INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPL,IAI.ICE. Cond: 22 (BL,DG.): COI{BUSTTO}r ArR rS REQUIRED pER CHAPTER ? OF TIIE 2003 rMc Al{D sEcrroN 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIIL,ER INSTALITATION MUST CONFORI,! TO MANUFACTITRERTS INSTRUCTIONS AND CI{APTER 10 OF THE 2OO3 IMC. Cond: 25 (BL,DG.): GAS APPIJIAI.ICES SHAIJJ BE VEI{TED ACCORDING TO CHAPTER 5 OF TIIE 2003 IFGC. Cond: 29 (BL,DG.): ACCESS TO MECIIAITICAIJ EQUIPMEI{T MttST COMPLY WITH CIIAPTER 3 OF TIIE 2003 IMC AIID CTIAPTER 3 OF THE 2OO3 IFGC.. so.oo ToTAL FEES------> $6,328.00 Total Permit Fee----- > 95,328-00 Cond: 31 (BLDG.): BOILTERS SIAIJL BE MO(IIIED ON FIJOORS OF ]IONCOMBUSTIBLE CO]IST. UNIJESS IJISTED FOR MOI]NTING O}I COMBUSTIBIJE FIJOORING. Cond: 32 (BLDG.): PERMIT,PL,AIIS AND CODE AIIAITYSIS MUST BE POSTED IN MECIANICAI-, ROOM PRIOR TO A}I INSPECTION REQI'EST. Cond: 30 (BIrDG.): BOIL,ER ROOMS SIIA],L BE EQUIPPPED I{ITH A FLOOR DRArN OR OTIIER APPROVED MEANS FOR DTSPOSING OF r.,rQUrD WASTE pER SECTTON 1004.5. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full ttre information required, completed an accurate plot plan, and state ttut all the information as required is correct. I agree to comply with the information ard plot plan, to comply with all Town ordinances and state laws, and to build this structlre according to the towns zoning and zubdivision codes, design review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 OR CONTRACTOR FOR HIMSELF AND OWNET APPUCATIONil LL NOT BE ACCEPTED IF INCOMPLET;R UNSIGrov Project ;TED i?RJOq- o(St Buitding-Permit@rS1' Mechanicat Permit *: lYlls- O llJ 97 O- 47 9 -2149 (Inspections) MMIAPYAIL 75 S. Frontage Rd. Vail, Colomdo 8 wffififfifio Heat LossCalcs.o EquipmentCut/SpecSheets CONTRACTOR INFORMATION Mechanical Contractor:Town of Vail Reg. No.:Contact Person and Phone #'s: Vz,; /zy v9/?2.-k &"2 gzc, V7p o;OO E-Maif Address3 t //^/? -/-/=_ s_@) 4 et Fax#:77a2 1.-r( ?7oo COMPLETE VALUATION FOR MECHANICAL PERMIT labor & Materials MECHANICAL: $ 2- '- 2 .id Conbct Asrcsrc Office at or visit for Parcel # Parcel #2.to.ta 7 2-a7 c> o z- Job Name: € a." 67.n /c- 2"^'- /r/Vn.,/,1 JobAddress: ?/,t cu. tf Z.i^ '4.,./ O't/. ?n;1 ?o, y1 /.,-d Legal DescripUon ll Lot:Block:Filing:Subdivision: ownersNamei )L t't-P lM&e*s?atg,>< ? rzA)t zo.Phone: Engineer:Address:Phone: Detailed description of work: Zu:/e/,/ 4// E-zn./on,.o2 o)// r^-o,u-*, -/t'' WorkClass: New)<) Addition( ) Alteration( ) Repair( ) Other( ) Boiler Location: Interior!6) Exterior ( ) Other ( )Does an EHU exist at this location: Yes ( ) No ( ) TypeofBldg: Single-family( ) Duplo<( ) Multi-family+V) Corr"tial ( ) Restaurant( )Other( ) No. of Existing Dwelling Units in this building: &No. of Accommodation Units in this building: O No/Type of Fireplaces txistinq{/€asAooliances ( ) Gas Loqs ( ) Wood/Pellet ( ) Wood Burninq ( Nofiype of Firepfaces Proposed: Gas Applian€rta) Gas Logs ( ) Wood/Pellet ( ) Wood Burning (NOT ALLOWED) Is this a conversion from a wood burning fireplace to an EPA Phase II device? Yes ( ) Nolf) ************************FOR OFFICE USE ONLy******************** blLb Zry*tr irt-ort7 Do4- ot75 Yxil. Co lor r(l{-' l)cnvi.r, Coi ( 'rad(l F.i$co, C('lora{Io Monroe & Newell llngittr:ws, lrre . June 27, 2006 Jim Wiley 4240 Architecture 5591 Coyole ridge Avon. CO 81620 Re: Gore Creek Place Tunnelwallopening" (M&N # 6285) Jim, Mike Graham with R"A. Nelson called today to request a letter addressing the openings placed in a non-bearing concrete wall in the shaft area of the fan room located at gridline 14.4, north of grid A. This is a non-bearing wall and the locations ol the openings will not affect the slruclural integrity of the wall. The upper opening should be filled with concrete. Additional reinforcement is not required at either opening. Please call if you have any questions or conem* Very truly yours, Monroe & Newell Engineers, Inc.4iL Mark Gee, P.E. Associate Principal 20S Ptrtlnra Spoctr ftE f4ltic th|r.{ of Tba Accricl &rlitrtl of,ntdirada 619 llair: sffcct r Srite 7 . Fri.rco. C:ol$rado tiO t'iJ r('7(l) fi6X-l?l(i . FAX trl?{t} d/r}1 t':J{A r l,mxi:. ,:';sIr}il8tn(1rlir1r,.rerv*'ll . tirrt oo o TEST, ADJUST AIYD BALANCE REPORT PROJECT GORE CREEK RES. T{JNNEL PREPARED FOR RANELSON REFORT ISSI'E DAf,E 6fTrrzw PREPARED BY |{-\/AC P.O. BOX 5t23 VAIL, CO 91658 PIK)NE: 970-331-1095 FAX:97O-92G9M o o H.VAC If,E DATA TNESHIT IT Tf,IS EEI(XT FTT TT|c[ MD(X SYSTEM PEruIORMAIiTCts AIID WAS OETAIHf,D trI O(M.tIlITCf, TTil llDB tttmnlLtrItrEllc. ltY vtlllre rIDr fm mlcil|DAmtDttD m rpIErlIrT tEs lDiln'f. rr lDs;IstilI.tD Endtttt lrumrxD !T rBslEllr E cr4Etu ltr' rfFr.rx rDoilIrlf., El rn f,xTf,riT FmisIBt f, BY EQ{npMXr{T Al\aD pB{rf,DIiBfIl USD,D TErfrrtr* {xtTTsf,IE4rtr- IE ItrTA,L IN HTTTBT}TIOFI SYSTf,M T}?E AST J E !.I &:. : Ir T.S A !f :: 115 ffi.IlJfro, Tfru lEE I5ETEJIIL Sf'.{lI{I}A*i},i l*Otr t rr.ri t [rii, A !.r-1tili l'll{G ,'\}il SALAr\eilG OI l,NVlROi\Mf,NTALSYSTEMS AND TIII ts fi f lJ r]L'l Si,CC I r'1{lA'fI$FlS. cc*rFiED ,t(- *to---6eZ'og 'r'Ir]t *':3],!f . i{ !'!}!:*l.itc !iISTR.iBUTION sysTf,lt{ Mf,AsuRf,.Mairls .\ i-: i,l :'i,., .., j f ! 1,1 \ ( : l: -\T : !'lt i\ *::l ii pt{( X':U!}I IRAL STAII-DAAI}S Ffnrf,lilret rxlirrE at}ll.llrE Cr Erml|a lt:RErFtrrufcEtilf,, (ETEfY:lrrB l+\'AG VARPJ{An; IilAT TI5 AIR'ID IIrIn(Nrc SYSIEX EVALUATED IXRIITG THA; $RVEY IS OPERAItrIG AT TIG SDUFIED LE yEt^f; AS Sfl}fl{ TIII]' TIIS TFtIr, Af AItr'(}LY Ar IItrS Tlrfi" I*UAG IIAIDS lf) (}IIII Ulff^rNrEsb STATED(I nfi.El), (IriGnNING TIIE COITITITTED }EEF(IIIATE (EIAIX)N (N.SrDf,TI T}I TIE TIs (F T16 T.A.B. G0illRAGT0rt t'Qa, ". EaurPf,|Elrr PAss THIS Tntr" o o FAN TEST REPORTH-VAE d*OJECT: o ,.-.^--_-_7ATrcS ( ,/' O.n" \/ ATMGS /' ./ O-7g^lr'\-- _/ o cf,lt @ o25rsP MO.rORDATA NOTES: PAGE: o o FAN TEST REPORTH.VAG o ROJECT: G.c.r. FAt{ t{tREER E ..CGiAl?lGE E/AST l EF6#r6 | UIIITDATA ITIITDATA II UI{ITDATA TATUFAGTURER GREEI{fCK MOI'EL TBl-FG3t-615 FRr6c I SERI.AL 05L04735 RATIIIG 96mcFf,i (0p.35'SP ancFll@o.{esP MOTOR DATA IIOTOR DATA MOTOR DATA I{ATf,FAC'NRCR IIARA'THON FA}ITECH MOTO,R HP RPII 17tt 1725 129W NG PIIASE I'ttPE 3 TS 1 NG s.F.FRAIIE 1-15 56tF70 1.O NG VOLTS AIIPS reZNffi 1.&4-8tL1 1t5 l-11 DNA'EDAIA BNN'EDATA DRN'EDATA MOTORIIRNI'E BORE 1l,P{'5rr DHECT TNNE FIflDRII'E BORE fPil}TOD I lfrl lt|('. BE-TS s7F 1 AF67 DRryEC}IA,IreC ROTAIF'I CORRECT CORRECT STIRfCROATA STARTERDATA IIFG.x(xtE-SCIi.iARED 8536S8G2 stzE RAT{GE 811-5 6-7-?-5 SETAT0Arilrsl RECLTIGru 4.8 TI{ERT{AL PROTECNOil MOTOR TEiTIIATA TESTInTA TE$TDATA cF[l v(f,Ts 95ait 2rrrzrl-212 17'r 777 trt tms l,lA 4-{H-I}3-9 ilA 1-1 NOTES: PAGE: H-VAG o FAN TEST REPORT o f OJECT: o o I rntt umen I EFS#ls I I I'MTDATA IIIITDATA I MAIi{'FACTI'RER FANTECH I MOT'EL FR16C SERIAL l.lc RATllrG I zncFM @ 0.,r0SP I# I moTofiDATA I IIOTOR DATA ilATNFAC TNER lrnrrecn MOTORHP RPT Irzgw I ING I PHASE TY?E 1 NG s.F.FRAIIE For-rs----l AtrPIt l-ll ,l Irs I Ir.re I DRTVE D ATA DRIVEDATA IMOTORDRN'E I BORE Fvtil\@--T DNRECT DRIVE FAil DRN'E BORE rrpo-oioo r ttz/ NO. BELTS SEE 1 ^ft/ I DRIVE CHAI{GE ROTATIOII cfnecr CORRECT I STARIER DATA srelqre/olra STARTER DATA mFG.H(X'EL SOUARED \8536S4G2 stzE RAT{GE 811.s /F.7-7.5 sETAT{ArpS}REo. II*RT \ THERITIAL PROTECTPII MOTOR /*toar\TEST OATA FFM YOLTS t@a zttzr\ztz ll'*-----,tl? |il AIIFS ll* /+.o+.o.3\ll* | 1-1 | 4.OT / / O.zs -o.n ( / o.28' NOTES: PAGE: o o FAN TEST REPORTH-VAC o OJECT: Arrffi ( 7 Arilos Arrros (7 Arrrros o I FAilHffiR I fsErsr I EF{uoAfl INTTDATA INTDATA TfiTIIATT raArlfAc'Irren €f,EET*ECT(CREEil€CK r|(xtg-sE|-ra*rz€sEl-12-.f32€ AEMAL fitEl /ffXl0 (FE1 4{x)O RATE|C 38s CFU @ o.15'SP 385 CFn @ O-15'SP TOTORIIATA U)TORDATA IIOTORI}ATA ilArf,rF c'TrnER FASCO FASCO ltoToRl?RPT t/a 1550 il8 1550 PHISE TIPE 1 tJa1B7 1 U2181 s.F.FRAIG 1_O tlG 1.0 tlG VOLTS Arpri 115 l-7 115 7.7 I'WEDATA I'RII'ET'ATA ORN'ET'ATA MOTOR T'RTVE BORE DIRECT DRTI/E TXRECT DRIVE FAI{ DR]VE BORE T{O. BELTS stzE DRIVE CTUI'IGE ROTATX'I'coreT CffiECT srnrcn UTA SIATE RDATA STffiIERDATA llFrc-r(IE- slzE NAreE sETAT(Amsl RCIO. r}Gil IT}ERTA-PROTBCTXX I'('TG ltoToR 'ESTOATI 'giTDATA TESTDATA cFu vflTs 660 1r7 q}z 117 NPT trrs DIA 7.1 r'tA 1-O l,toTEs: PAGE: oo DEPARTMENT OF COMMUNITY DEVELOPMENTTOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMRS .._ J n@ob PLUMBING PERMIT Permit #: P05-m65 l)ut " t Job Address: 790 W LIONSHEAD CR VAIL Stahrs . . . : ISSUED Location.....: GORE CREEK PLACE TUNNEL/PARKING Applied . . : M/09/2W5 Parcel No...: 2l0lO72W0A2 Issued. . : Ml2lDnS ProjectNo: o, Expires. .: l2ll8l20[5r!o./-or 3l otitNER vArr, coRP 06/09/2005 PO BOX 7 VAII, co 816s8 APPIJTCANT MID COIn{TY PIJITMBING & HE"ATIN06/O9/2OO5 phonez 97O-468-4924 P. O. BOX 23L86 SIIJIERTHORT{E co 80498 Lricense: 269-P COIVTRACTOR MTD COI'I{TY PI,UIi{BING & HEATINOS/Og/2005 PhONE: 970-468-4924 P. O. BOX 23L86 SIITVERTHORNE co 80498 License:269-P Desciption: GORE CREEK PLACE TLJNNEL/PARKING-INSTALL ALL PLUMBING IN TUNNEL Valuation: $252.495.50 Fireplace Information: Restriced: ??# of Gas Appliar€s: ?? # ofGas Logs: ?? #of wood Pallec ??*+ar|r+ir*,t+r.irl,rrt{.i,rtr**r.*r*'r*trrrr.+t'rr|t|tr*ra,r*a*r**.*r:r{.rt|rr,rr+ FEE SLIMMARY++itta**:ltt*t*||a{r*a**a*&t|.!t*{.!l*a+ttttttt,!aralaria+l.*a.ta*t '}'ta't Plumbing- > S3 , 795.00 Resfiarant Plan Review- > Plan Check-> S948.75 DRB Fee------------ > s0.00 Total calculated Fees-- > i4 ,745 .7s So. oo Addftional Fees------- >90 .00 Investigation- >So.0o ToTAL FEES - S4,?46.?s Total Permit Fee----- > 54,746.7s will cdl---- > s3 . OO BALANCE DUE-------- > F4,746.75 $0. oo rTEM: O51OO BUIIJDING DEPAR${m{T o6/o9/2oos Js Action: AP Item: 05500 FIRE DEPARI'!{EIII CONDITION OF APPROVAL Cond: 12 .l?.P*.9,-;J*;'.lT*ll*.,.I*Tf*.t,-T*:l-t.9I:.-**."HgYIY"3"*T9..fll3f-T-i.91-,-",..o3.T-f9l1lllH9*-t;****"**r++,i,i*,*,,+***,r*,,i*r*rr DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and stat€ that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, Intemational Building and Residential Codes and other ordinances ofthe Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOI,R HOURS IN ADVANCE BY TELEPHONE AT 479.2149 OR AT OTJR OFFICE FROM 8:OO AM . 4 PM. .z ,/4rd dn.y'"-- **tt*****++*lt*ffl*l*'}+**l**lll*tt'i'3**'t***tlltttllt*+a++++*t++++*ltt*******'|'i*****'t'l+++++*** TOWNOFVAIL, COLORADO Statement {'*'1"}'}*****++*'l't*'l*tlf tf +*r}'}'}*'t't*ttf lf**+*'}*'ttrtr*a************'}'}'t*tllf *+f ********tt'}*f ******** statement Number: R050000891 Amount: 94.746.75 06/2L/200509227 ?t'r! Palzment Method: Check Init: LC Notation: #3116/Mid County P & H Permit No: P05-0055 Type 3 PIITIIIBING PERIT{IT Parcel N.o: 2\OT-O72-O7OO-2 Site AddresB 3 790 W IJIONSHEiAD CR VAIIJ IJocaI,ion: GORE CREEK PIACE TT,NNEI,/PARKING Total Fees: $4,746 -75This Payment: 94,?46.75 Total AIIJ PmtE: $4,746-75. Balance: $0.00***:t**++**++**+**+*********+**a*tt+ta*******l+*a*+aa*******t*t*+it++****************+******* ACCOUNT ITEM LIST: Account Code DeBcription Currents Pmte PF 00100003112300 pr,AN cHBcK FEES 948.7s PP OO1OOOO31111OO PLI'MBING PERMIT FEES 3,795.00 wc 001-00003112800 WIITIJ CALL INSpEerrOri[ FEE 3. oo APPLI cATr? wrLL Nor BE AccEprED ,r rn.o"r?, '-r'".T#i"?UoJ- 0,3 t Building Permil #: Plumbing Permit #:6S TOWNOFYAILW, 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION Plumbing Contractor:Town of Vail Rpn Nnl Contact.and ehone *r's: V7JQ76@,azz.Z &"2 ?zo 7zp o6y/E-Maif Address: ffilffij (-aa, Contractor ttn"y; GOMPLETE VALUATION FoR PLUMBING pERMrr (Labor & Materiars) AssessorsJ?fllce at 9Z0-329-9640 or visit Parcel # 2/O,/O JOb AddreSS: 2 9 O U - tf Lt a* s6 <,a../6-, Tafsrza:/ ca. x/ 6 ra OwnersNu :;oJ_ (r. Addition ( ) "Atteration ( )Repair( ) Other( )Typeo3|g':Sinn*fa'n,'rt l ounru't ) No. of Existing Dwelling Units in ttris buildino: --{l No. of Accommodation Units in this buildino: a conversion from a wood ing fireplace to an epFFhase It?eviceZG ***************************************FOR OFFICE USE ONLY************************************* i,' t II t. t- i I t I! ! I I I FIUscrs\cdev\FORMS\PERMtTS\pLMBpERM.DOC \n*'f,+d I I/t8/2004 .4r(JilT Frtrt0 a FlLL UL[}L[-otV1 0&1&2005 Inrpccfron Requett Reportlng Page 15 4;34 ern veil- co - clhr ctl Requeeted lnspcct 9ate: fdday, June 17, 2005' InspecdonArea: CD SlbAddress: <None Lllted> 790 I,EST LIONSHEAD CIRCLE @g.!s@SE Actr,ltu BO4{194com!Tlpi:T\rce: COMBIILD occwaity: Strtls: Insp Area: tsst ED CD Onnier: VAILCORP ADplhanl: R.A" NELSOI.I & ASSoCIA'IES, ltlc Coiibacbr: R.A. NELSON & ASSOCIATES, hrc, )eicdD[on: IIODIFICATION OF EXI$ltlG MAF Insoccdon Hlsbfl ilom: 502! PlrtRowh[.m] sGl Pu&Fh.Id Req|esbdTlmer 10:00At- Phone: 97O9{t-5152 Enter.dBy: LCAITPEELL K otriien VAIL Phom: 97$9{r-5152 Phom: 970''9495152Coiibacbr: RA.NELSON&ASSOCIA'IES,hrc, Phone: 9 DeicdDdon: IIOOIFICATION OF EXI$ltlG MARRIOTTP RKltlG SIRUCruREt$llce: Artll0onsl Nb reclemd l@(X tfo fuil&r l€yLrJ urtr oaddno oaram anah/sb b D€dormed showlm ll sar.E€ b oDen or cbsed. A comndfmil b In$all i sfkrFe-r sy$am atio n$foed du€ b bss of'Ec&ss-on sodh slde ol smrcfu€ - cDAVtS l,lolhe: RAMhons6ntrmlh€rchocklntheanpuntot$lS2E.T5tocpwrlh.babnce,btttthbhasolleadybeen !old. i.lcd b Jetum tho ch€ck wnh a copy ot tho recclpl. - LCAITIFBELLl.lolk€: ILC ft,r dtvcvr.v orrde .3cbv€d and roulsd to Publlc vr,odc . CDAVIS Cornnrnt ROtfiED TO CIIARUE DAVIS. WARREN C IPtsELL FIRE Al.lD PT BL|C UTCRKS - JSIUI}IER CoIIIIil.nU FIRE DEPT. STAGII{G AREA DRAWIT{GS ST,BTIITTED AIID ROI,,IED TP CFTARLIE DAVIS, VUARREN CAT|FBELI, FIRE AID Pt',BtJC UiJRKS..T$UITIER Commenl DRTVE AiIO PARKII.IG ALTERATION ORAWI}{CiS St,8I,frTTEO ANO ROt,IED TOCTIARLIE DAVIS, U'ARREN CAIIPBELL. FIRE AI.ID RJtsIrc VIJORI(S. J{}I'I}IER Codme]tt I,PDATED REVISIOiIS SI,BT'ITTED AND ROT,TED TO WARREN CAMPBELI, CMRLIE DAVIS, RRE AtrD RELIC UFRKS - JSUTHER Reoue€bd lnsoecflon(sl lEm: 00 Buxt+lnd Reque€led Tlmel Requcbr: R.A-}.IEISON&A,SSOCIAIES, ltlc Plpm: corim.nb: Ptl. wll ca[ 471€04) Asslgned To: COAVIS En[ered By:- Acflon: Tln€ EIo:E.oflIr]* F[7tTNI[Eifi,8-IC YIPRKS ANb FTHE-N+FOVALS REOD. Comrlnt 08:30 AIU 4Tl€{lrl(t DGOLDEN K -ADgtowd*Actott: APAPPROVED 54{t Bt-DG.FhCrO RT. NELSON &ASSI REPT131 l2t14tu a Run Id: 3315 0&1&mos Inspcc{on Eequqgt t0lU04-lmpodor: Art Actbn: APAFFROVED COMMTNt APPROI/ED FOOTI}.IG STEEL AT SOTJTH EAST CORNER OF BOTI1OII LEVEL Item: 20 BLDGFourdqtbrVStEgl " Approved - lOzOIt4 lnrD.cbr: C€D Acdon: Pl PARnAL NSPECION Commcnt 2COtt MNSAI\DFDNI|IIALI lNO RAOE. Page 17 lbm: 30llem: 50 nam: 60 liem: 7t) 530 ELDG'Temp.C/O11l24lg ltr$l_!||D.6r._ cd.rA AcTIon: APAPPROVED -ApprDwd. Acton: DND€NED Acflon: tlo].loTlnEDr..lll€ Ac|,on: APAPPROVED 11,16,(f Inc9.cbr: GCD Comnr.nt S|TE RETAIMiIO WAIL. BLDeFr.mhgELDG|nslilrbn BlDfshe€tocf t{t[ BLDelMkc. 1ll17lfJ4 Inspedor: cdavls Ac{on: l,lOl,lOTlFlED Comm€nt F.ISPECNON NOT REOT,ESTED FOR TODAY CONTRACTOR STATES IM'PECTIOTI OCCI'RRED YESTERDAY It m: g) BLDeFh.l "ADorowd" 12l1ECr4 tnsoector: GCD Actlofl: DN DEMEO Com'mf* PL.ANM].IG. PUBLIC VIICRKS AND RRE APPROVALS REOD. 1U21lU Inrp..tor: cd{rls AcUon: APAPPRO\,EDComrmlt lLm: lbm: 5ii3 lLm: tt:t7 Comrnnt Pbnilm.Fkc antl RSlc lSrlcc rpprowb r.qu -iluC Acyfcc rnd pEfW rerrb.d dnttlgE 4rndho Fquhed .t enty (bolfrr fi|g|,stucfirrrl cminerr approul regu$rd -A[ cLcillcrl condrit ihal ba racured ln rn rDt Plrnilm.Fkc antl RSlc ISIIcc rpprovrb rc$drod -lluC Acy fcc rnd pEfW rerrb.d 4nytlgE EtrEl cngirb.r .pgforl regusrd conduil ihal ba racured ln an rpptovld mannat -Ronpw iamp strl|s hom l/Lnbl troDl -Ehe Ahm- rtbil opqrloml .nd rDc.t0fil3d 1ztr,to,. fielmpocilon retnilrcd UFpodofi c(hrl3Coonrnt Stirc Englnrr rgon lrchrd r.. lll€ 1?Ji21l(J/- Insoccbr: @rF Acl EUUG Eng[fi]ar 1r9O Inspccfu: @rF Item: 53t nsm: 53i! Comm€nt alliDneciloffi ma& -_ l.lo-tuther lrEpecfrorE reqirodfiom Bufldhg Depettn€ni FIRE.TET'P.C/OPtllTElF. C'/O * ADproved -1112{[l/ lrl3pector: b - - Actlon: DN DENIED Commnt Nol R.edY. 12l1UfJ4 lmprdo|:' b Acilon: ON DENIED Com||rnt R. A. ilctson hoe p|ovlft m wffi (lltway gnfir trom PLC. hrt sbllt9.d fiom Ahhs FSFF; * D th.r oryn chilvry {r.d.r.\AIIUU In p.ctof: b Ardon: AP APPROVEDCgoillirr: 6llrlp.d Clv.rr.y gr.{l. tlom PLC h.. bo.n Fov||L .nd lPP|ord !y PW.PlIt+TEilP.CrO' -'A6oovrO- 11t24o4 InrD.ctor: Yvcmn' Acdon: DNDEMEDCo|trtlnt Ail i![tr6 and cur ooDcrrtn rrcGd lo ba rlrd. The now 'elrlnlno wlr Deo(b lo bo 9.lnfft l. Al hnc|scrFhg uthtt rrs rcrnowd n cdn'lo tr rplcrO. YY. n oil !o wod( logpbat 5 s.c f |h.rl b a bc0br op0on ln t nrt3 ol locllion lor tho ea$m glb .m opemr. 12114104 IniDc6r: 'lYlmn Acilon: AP APPRO\IED Comrnert In3\,oc,able Leler of Credlt sccepted on December 11,M. P[J{!'}FIML C/O - ADproY€d - 040erc5 Inspedor: $darnd' Actlon' APAPPROVED Comlmnt Thi rtrlnho wal loc.bd on lh. roulhwsg corner ot $. l,tarlot rhall be cbd h Sorx ln cor{unclbo *Ifr tho C'oro Creek RcCcbncos. ln lhe rneln trne I wltl br peffied to mrtci $epsltru rfrcu0nr. FIREfI}.IALgO PYIIFIMLC/OBLDf,tFhrlC/O '- ADorovod "1A27tU lmp*nor: ctbvli' ftdon: AP APPRO\,ED\ Comment t{o'ftJrlhil lmpccilo€ nqulrod from Buldlog D.pa Item: 538tbm: 539llen: S40 REPf131 Run Id: 3315 PRTbY_6r:51 3c.t-otot 06-27-2006 4,43 p, Inspec$:itF?$yF?ftffPortins P"s" 15 Requested lnspecl Date: InsDection Area: Site Address: A/P/D lnformation Activitv: E05-0073 Tvoe: B-ELECConslTyp6: Occupahby:Owiier: VAIL CORP AoD|icant: PATTERSON ELECTRIC CO Cohtractor: PATTERSON ELECTRIC CO Description: ELECTRICAL ROUGH AND FINISH FOR TUNNEL Requested lnspection(s) Wednesday, June 28, 2006 CD 825 FOREST RD VAIL 790 WEST LIONSHEAD CIRCLE.GORE CREEK RES Sub Tvpe: Use: Phone: Phone: Action: AP APPROVED Action: AP APPROVED Action: AP APPROVED grid line Action: AP APPROVED tl6 thru #8 underoround conduit east end bv stairs.Action: Pl PARTIAL INSPECTION IT IN FOUN TION WALL NCOM Status: ISSUED Inso Area: CD 970-468-6166 970-468-6166 Item: 190 ELEC-Final Reouested Time: 08:30 AM Reouestor: PATTERSON ELECTRIC CO Phone: 970-468-6166 ConimeDts: final for the invertor, Gore Creek tunnel Assigned.To: SHAHN _ EnteredBy: DGOLDEN K- Action: Time Exo: Comment: Provide Tne aF ws in the exits liohts oE?Zbbi-oved Dlans. Emergency lighting has not beefr tested ai invertei not fully charged. E.C. to schedule. I Inspection Historv Item: 1 10 ELEC-Service 08i12/05 | Comment: I 10t18to5 Comment: 03t22t06 Comment:Item: 120 ELEC-Rouoho5t24to' Comment: 05/31/05 Comment: 06/03/05 Comment: 06/09/05 Comment: 07/19/05 Comment: 07t28t05 Comment: 07t29t05 Comment: 08/25l05 Comment: 10/04/05 Comment: 101111o5 Comment: 1'U07t0s Comment: 1'U't0lo5 Comment: 't2t05t05 Comment: 01/18/06 Comment: 0'U27tO6 Comment: 03/03/06 Comment: 03122106 Comment: 04t25t06 PARTIAL INSPECTION FROM GRIDLINE 25 TO MECHANICAL ROOM. PARTIAL INSPECTION.HRU 5.2 APPROVED. PARTIAL INSPECTION as prevrous. REPTl31 CONDUIT I Run Id. 5446 !e T-o-zs- 4 4:36 om Vail CO-- Cittl Of - Requested Inspect Dato: Erjday, June 30, 2006' Insoection Ar€a: CD Site Addr$s: 825 FoREST RD vAlL GORE CREEK PLACE TUNNEUPARKING A/P/D lnformatlon Activitv: M0$0117 Tvpe: B-MECHConstTyp6: Occupahby:Or/rier: VAIL CORP Applicant: MID COUNry PLUMBING & HEATING Contractor: MID COUNW PLUMBING & HEATING Comments: Assioned To:- Action: Comment: Status: ISSUED lnso Area: CD Phone: 970-468-4924 Phone: 970-468-4924 Description: GORE CREEK PLACE TUNNEUPARKING-INSTALL ALL MECHANICAL WITH SNOWMELT Reouested lnsoection(e) Item: 390 MECH.Final Requestor: MID COUNTY PLUMBING & Reou€sted Time: 08:00 AM' Phone: 4714071 Entered By: DGOLDEN K ITEMS. lr section east to west. tested for 100# air test IC SUPPLY supply air ' Action: AP APPROVED GARAGE ANDLOWERENTRY Action: CR CORRECTION REQUIRED r^rlLr- Br coot<-Eo INSPECTIONc. 100#AtRTEST. INSPECTION Hr:, IPMENTLESSTHAN 7FEEr._,n agJfiTFc curoPENrNGS &(AftO - ) Action: Pl PARTIAL INSPECTION ;. MAKE UP AIRAND DUCTING FOR GARAGES: f5.16. BUTLD 2 UNTTS 13.14.rn Action:' Pl PARTIAL INSPECTION04t12to6 Comment: 04t25t06 Comment: 04t26t06 Comment: 05/03/06 Comment: IPROVAL UNIT HEATERS AND SNOWMELT Item: 310 Item: 315Item: 320Item: 330Item: 340Item: 390 SubTgOe: NCOM REPTl31 Run Id: 5452 06-29-2006 Inspection Request Reporting Page 16 4:36 pm Vail- CO-- Cit_v Of - Requested Inspect Date: Friday, June 30,2006' lnsoeition Area: CD - Site Address: 825 FOREST RD VAIL GORE CREEK PLACE TUNNEUPARKING A/P/D Information Activitv: P054065 Tvoe: B-PLMBConslTyp6: Occupahby:O\irier: VAIL CORP Applicant: MID COUNTY PLUMBING & HEATING Contractor: MID COUNTY PLUMBING & HEATING Item: 210 Requested Time: 08:30 AM' Phone: 471-0071 Entered By: DGOLDEN K '* Aooroved *| " Action: Pl PARTIAL INSPECTION:ROM AREA DMINS IN STAIR WELL ON 1 LINE TO 5.2 AS NOTED ON Art Action: APAPPROVED TUNNEL AREA UNDERGROUND DRAINS FROM GRID 5.2 TO GRID 10.3 AS THE PLANS at grid linew PARTIAL INSPECTION between a-b line from trench drain to interceptor SubTgne: NCOM Phone: 970-46&4924 Phone: 970-468-4924 Status: ISSUED Insp Area: CD DescTiption: GORE CREEK PLACE TUNNELiPARKING-INSTALL ALL PLUMBING IN TUNNEL Reouested Insoection(s) Item: Reouestor: Coniments: Assioned To:- Aclion: Comment: 07l27lo5 Comment: 08/11l05 Comment: 08/19/05 Comment: 01t12106 Comment: o1t20to6 Comment: 02t03t06 Comment: 04t25to6 Commenl: 05/03/06 Item: 230 Item: 240 Item: 250Item: 260 Item: 290 PLMB-Final DEEKSTORM DMINS AREA D FLOOD LEVEL TEST. THIS COMPLETES DRAINAGE, Waterlnsoector: GCD Action: Pl PARTIAL INSPECTION DOMESTIC COLD WATER SUPPLY FROM GRID 1 TO 1O IOOOS| TEST. ub Inspector: GCD Aciion: Pl PARTIAL INSPECTION ST08M LEADERS FROM TUNNEL DECK 3 UNDER FLOOR RIM TESTAND 2 UNDER Spsi AIR TEST. REPT131 Run Id: 5452