Loading...
HomeMy WebLinkAboutVAIL VILLAGE FILING 1 BLOCK 5D LOT O MASTERS GALLERYVarl /,.Ua7,a l=zfa'ita I BIoc(UD, Lof- o /a;l U//E TpD lVost'oes ary Cqtft*mlTY tEtELOPrEXT Design Review Board ACTIOH FOR],I Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 taxz 97O.479.2452 web: www.vailgov.com Project Name: Project Description: Padicipants: Project Address: Legal Description: Parcel Number: Comments: MASTERS GALLERY CHANGE DRBNumber: DRBO70707 FINAL APPROVAL FOR A CHANGE TO THE APPROVED PLANS TO REVISE THE LETTERING AND MONAGMMS FOR THE MASTERS GALLERY DOOR AND AWNINGS OWNER MASTERS GALLERY AT VAIL LLC I2IL7I2OO7 70 S POTOMAC ST AURORA co 80012 APPUCANT MASTERS GALLERY AT VAIL LLC 12IL7IaOO7 Motion Byr Second By: Vote: Conditions: 70 S POTOMAC ST AURORA co 80012 1OO E MEADOW DR VAIL LocaUon: UNIT #27 Lot: Block: Subdivision: VAIL VILTAGE PI-AZA CONDO 2101-082-5601-0 SEE CONDMONS BOARD/STAFF ACTION Action: SIAFFAPP Date of Approvah L2lL8l2N7 Cond: 8 (P|-AN): No changes to these plans may be made without the written consent of Town of Vail staff and/or the appropriate review committee(s). Entry: 1211812007 By: Rtf Action: @ND 1. The three apprwed business signs on the awnings shall only be allowed if the business rctains three publh entrances that are open and accessible to the public during all business hours. Should any public entrances be closed during business hourc, the business shall remove signage as necessary. 2. The sign on the awning above the eastern side door is not approved as part of this application. Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. @nd:201 DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Town Code, Chapter 12-3-3: APPEALS. Condr 202 Approval of this project shall lapse and become void one (1) year following the date of flnal approval, unless a building permit is issued and constructlon is commenced and ls dillgently pursued toward completion. Cond: 113 All development applications submitted to the Town after the eff€ctlve date of Ordlnance 25, Series 2006 shall be subject to the pending employee housing regulatlons in whatever form they are finally adopted; provided, ho,vever, that if the Town fails to adopt the pending employee housing regulations by April L5,2007, this Ordinance shall not apply to such dwelopment applications. Planner: MCHEL FRIEDE DRB Fee Paid: $2O.OO Changes To The Approved Plans Depatment of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2L28 fax: 97O.479.2452 web: www.vailgov.com General Information: All projects requiring design review must receive approval prior to submitting a building permit application. Please refer to the submittal requirements for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Department. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission. Design rcview approval lapses unless a building permit is issued and construction commences within one year of the approval. PhysicafAddrcss: tOO gHf -Vgmowffip",olno@(ContactEag|eco'Asse5sorat970-328-85,+0forparcelno') Mailing Address: Owner(s) Signature(s): Name of Applicant: Mailing Address: 1./ J .cl&tot.Cgry1TVyof Review and Fee: \', ,p chanoes to Approved Plans $20 Fj-,Tli:':.i:_gJ]ans already Application for Design Review e6 6 oot2- ,tu J ,--,*Tlly 3 ovov <r/ Design Review Board. Submittal Requirements: 3 Sets of Plans AddressinS Project Changes Signature of Homeowner(s) or Association C:\Docurnents and Settingswastersl\Local S€ttings\Temporary lnternet Files\Content.lES\77NYR3L4\drb_change_to_approved ptans_1_page_10-18-2O0611l.doc I{ame(s) of Owner( E'Gffirrtl,.V"lF" DDEC 14 2007 rowN oFlvai! For Office Use Only: Fee Paid: ZS check No.:?/zt ,v, W.llra*r /('wdq{ f Meeting Date:/-[(--$g o*rro.. DGOo?o7o7 +4 I r-Planner: l\{-f Prcject No.: Slifer Management Company Property Management & Leasing December 13.2007 Town of Vail Department of Community Development I I I S. Frontage Road West Vail, CO 81657 Re: Masters Gallery To Whom It May Concern: Please be advised that the Board of Directors of the vail village plaza condominium Association has approved the following improvemenrs proposed by the Masters Gallery: r Installation of awnings in five locations. They will be the same color as the existing awnings. r Replacement of their main entry door with a new door of the sane dimensions. They are replacing the door with a newer version because of safety and security reasons. The new door metal will be a brown color that will better match the new railings that have been installed near the gallery. o The Board of Dire ctors understands that minor modification of amending the monogram on the awnings may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations. The Board of Directors believes that these proposed changes are improvements to the property therefore we hopc that the Town of Vail will approve them. Sincerely, Vail Village Plaza Condominium Association P,O, Box 2264, Edwuds. CO 81632 0105 Edwards Village Boulevard, Suite G-206, Edwards, CO E1632 Telephone: (9'10) 926-79 | I Tetefax: (970\ 926-7 9 14 townofvai12cdh.doc Page r of r [{srrr.sGrrrr-r \i {l- i', r \, $ ,.{u\V ^.4\'NA\ TDWN OT VAII sFepxf''-w^' lz \tr(.''+ --DATE' --'-e-rj-+ STA.FF: file:r/rzC:\Documents and Settings\Mastersr\Local Settings\Temporary Internet Files... tz/t3/zoo7 Page r of r t',, L:,1, I,I 1\{,rrrrr r(9r rrr.r File://C:\Documents and Sett ings\lv{astersr\My Dc,cuments\Gallery Pics\Side Awni... rt/13/tooT Page r of r n -\ "^rol \ y' 4 vYt- file://C:\Documents and Settings\Mastersr\My Documents\Gallery Pics\West Entr... rz/t1/zoo7 q'l*.FlrY tElELoetEf.l- Design Review Board ACTIOI{ FOR}I Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tef: 970.479.2139 ta'r' 970.479.2452 web: www.vailgov,com PToJect Name: MASTERS GALLERY DOOR/AWNINGS Project Description: Pafticipants: FINAL APPROVAL FOR THE MASTERS GALLERY DOOR AND AWNINGS DRB Number: DRB070618 Location: UNIT #27 OWNER MASTERS GALLERYATVAIL LLCIOI29I2OO7 70 S POTOMAC ST AURORA co 80012 APPUCANT MASTERS GALLERY AT VAIL LLC IOI29I2OO7 70 S POTOMAC ST AURORA co 80012 1OO E MEADOW DR VAILProject Address: Legal Description: Parcel Number: Comments: LoU Block Subdivision: VAILVILLAGE PLAZACONDO 2101-082-5601-0 a\ i\ Motion By: Second By: Vote: Conditions: BOARD/STAFF ACTION ACTION: STAFFAPP Date of Approvalt L0|3U2O07 Cond: 8 (PLAN): No changes to these plans may be made without the wriften consent of Town of Vail staff and/or the appropriate review committee(s), Cond: 0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to construction activities. Cond: 201 DRB approval shall not become valid for 20 days following the date of approval, pursuant to the Vail Tolrn Code, Chapter 12-3-3: APPEALS. Cond: 202 Approval of this project shall lapse and become void one (1) year follorrving the date of final approval, unless a building permit is issued and construction is commenced and is diligenUy pursued toward completion. RACHEL FRIEDE DRB Fee Paid: $25O.OOPlanner: Minor Exterior Alterations Application for Design Review Deparbnent of Community Development 75 South Frontage Road, Vail, Colorado 81657 t€l: 97 O.479.2L28 f. xt 97 0.479.2452 web: www.vailgov.mm General Information: All projects requlrlng design review must receive approval prior to submiting a building permit application. Please refer to the submittal requir€ments for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is recetued by the Community Development Department. The project may also need to b€ rsriewed by the Town Councll and/or the Planning and Envlrcnmental Commission. Design review approval lapces unless a building pcrmit ir issued and construction commences within one year of the approval, Descriptaon of the Request:\rcz -t0 yl^AT\ c.iA<€ Svts> t A krp,r',,S ld r'.rH 11-tO'\) IJ4ME- c-4QP-P r)oo.a Locauon of the Proposat: Lot: Btock:- rr66guggon' VA, I V, ll*eta t-n'r physicarAddress: loo E*sf l'J\e *oo,,.: Dn+21 , /+,[ Co 8165? parce|tto.:@(ContactEag|eCo.Assessorat970.328.8640forparce|no') iZoning: l-\uP 6J 4 0 0' \ @ ru.( f)!tgr^rL* Name(s) of Owner(s): l.lailing Address: Owner(s) Signaturc(s): Name of Applicant:A+-TreS \\en +t /A.t LLc, Type of Review and Fee: l,-./Is srgns E Conceptual Revier,v El New C-onstrucdontr Mdition l,faitingAddress: *7A 9Ot-::r+ -PdJtmte A,rronp. Ct, KCrtlL Phone: E-mail Address:'?rLettorfr*i-(ota 66*. ,b3 b'IS lO+1 $s0 prusg1.oopersquarefootoftotarsignur*. -GE@;ro No Fee $650 For construction of a new building or demo/rebuild. $300 For an addition where square fuotage is added to any residential or ,/----\ commercial building (includes 250 additions & interior conversions). \ $250 ) For minor changes to buildings and site improvements, such as,\---'l re-roofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvements, such as, re-roofing, painting, window additions, landscaping, fences and retainlng walls, etc. $20 For re\risions to plans already approved by Planning Staff or the Design Ret ietr', Board. No Fee tr tr y' uinor Alteration (mulu-family/com mercial) Minor Alteration (single-family/duplex) Changes to Approved Plans S€paration Request Fgrff*f.{|t' ch*rNo., v6?6 ey, l,l- z(- o7 MINOR EXTERIOR ALTERATIONS TO BUILDINGSAND SITE IMPROVEMENTS SUBMITTAL REQUIREMENTS General Informadon: Thls application is requircd for proposals involvlrE mlnor oftedor alteraflons and/or slte lmprovements. PqPosals to add landscaping do not require DRB approval unless they involve the addition of patios, WaGrTeatures, gradirp, or tfre additlon of rctaining walls. I SI'BMITTAL R,EOUIR,EMENTS*:T o Stamped Topographic Survey*o Site and Gradlng Plan* o ,,Landscape Plan*{ rfucnitecfur al Elevations*( b(terior color and materlal samples and specifications.o Architectrral Floor Plans*o Llghtlng Plan* and Cut-shee(s) for proposed fixturesq TrUe repo( includlng Sdrcdules A & B to verify ownership and easements*D Photos of the existing site and adjacent structul€s. where appllcable.o Written approval from a condominium association, landlord, and ilint omer, if applicableo SiFspedflc C*ologlcal Hazard Report, if applicable*o The Administrator ard/or DRB may require the zubmission of additional plans, drawings, speclflcations, samdes and other materials (induding a model) if deemed neessary to determine whether a project wlll omply wlth Deslgn Guldelines or if the inEnt of the proposal is not clearly indicated. Pleaw ssbrttt rlree (J) ctpbs a//fr e natenbb aaled vtrl aa a,fiaist (). **For interior @nversions with no elterior dlames, the submittal requlnemenb include a compleE set of odsting and proposed floor plans, a title report, and written appnoval from a condorninium association, landlord, and jolnt owner, lf appllcable. I have read and underctand tte above llsted submlttal lqulrements: Project l{ame: Contractor Signature Date F: \adeAFORMS\Permits\Planni ng\Old forms\d rb_minor_alt-8-z8-2007.doc PagE 3 of 13 Buildino llabrials Roof Sldlng Other Wall Materials Fascia Soffib Windows Window Trim Doors Door Trim Hand or Deck Rails Flues Flashing Chlmneys Trash Enclosures Greenhouses Retalning Walls Exterior LighUng Other Notes: PROPOSED MATERHLS TVpe of l.latedal Color 8 \ ec-'t-p-ic 5l r r,r vr.e1 N1p-r,4{ b6c'a-9 a\- ^l I/\ *rtDil )Hffi.' NOTES TO AII APPLICAT{IS Prc-aoollcatbn l{eetino A pre-application meeting wtth Townbf Vall sbff is enouraged. The purpose of a pre-application meeting is to ldentlfy any critical issues pertaining to the applicantt prcposal and to determine the appropriate derclopment review proess for an apdlcauon. In many cases, the prc-appllcauon meetlng helps to expedlte the development review process as critical issues are ldentfled and dealt with in the preliminary stages. A pre appflcaton meeting may be scheduled by ontading Joe Srtrer at 970.479.2L28 or jsuthel@yallggv.aom Tim€ Rduircments The Design Radew Board meets on tie 1st and 3rd Wednesdays of eadr month. A complete application form and all acompanyrrE material must be acepted by the Community Development Depaftment prior to appllcaUon deadllnes. A schedule of DRB meefngs and associated appllcaton deadllnes may be found on the Wot1d Wlde Web at www.valloov.com For a ne$/ resldentlal development, the application deadline is typically 3.5 weeks prior to a Design Rer/iew Board hearing. Rwiew Criteria The proposal wlll be reuaryed for ompliane with the Design Guidellnes as set forth in Title 12, (Zoning Regulations) and TiUe 14 (Development Standards) of the Town of Vail Municipal Code. Reouircments for orooeftiee located in hazard arcas If a property ls located in or adjacent to a mapped hazard area (i.e. snow avalanche, rock fall, debrls flow, floodplain, wetland, poor soils, etc.), $e Community Development Depafinent may require a site-specific gedogical inrrestigafion. If a site-specific geologlcal Invesfrgatlon determines that the subject propetty is located in a geologically sensltive area, the property owne(s) must sign an affidavlt re@gnizing the hazard repolt prior to the issuane of a building pennlt. Applicants are strongly encouraged to consult with Community Development staff prior to submitting a DRB appllcaton to determine the relationship of the propefty to all mapped hazards. Reouired Plan Shed Format For all surveys, site plans, landscape plans aM other slte lmprovement plans, all of the follorring must be sho^rn. Plan sheet size must be 24nx 36". For large prcJecE, larger plan size may be allowed. Scale. The minimum scale is 1"=20'. All plans must be at the same scale. Graphic bar scale. North anow. Tltle bloclg project name, project address and legal derription. Indication ofplan preparer, address and phone number, Dates oforiginal plan preparation and all revision dates. Vicinity map or location map at a scale of 1"=1,0(X)'or larger.9. Sheet labels and numbers. 10. A border with a minimum left side margin of 1.5". 11. Names ofall adjaaent roadways. 12. Plan legend. 1. 2. 3. 4. 5. 6. 7. 8. F:\cd6^FoRttls\Permits\Hanning\O{d forms\drb_fi| mr_alt-8-28 -2m.7.de Page 9 of 13 Desion Reviw Board Meetino Reouirements For new constr.r<tion and additions, the applicant must stake and tape the project site to indicate property lines, propo6ed buildings and building corne|s. All trees to be removed must be taped. The applicant must ensure that sbking done during the winter is not buried by srnw. All site tapings and staking must be completed prlor to the day of the DRB meeting. The applicant, or their representative shall be present at the Design Review Board Hearing. Applicants who fall to aqPqqr before the Design Rwiew Board on their scheduled meeting date and wlro have mt asked in advarlc that dlscussion on their item be postponed, will have thelr ltems removed from the DRB agenda untll such tlme as the item has been rcpublished. If the tlRB approves the application with conditions or modifications, all conditions of apprwal must be resollfed prior to the issuance of a building pernitr'.. '. r Staff Aooroval The Administrator (a member of the plannlnS stafD may revlew and approve Design Review applications, appKtve with ertain modifications, deny the application, or refer the application to the Design Review Board for a decision. All statr approvals are rerdewed by the Design Review Board and any staff decisidn is subject to final approval by the DRB. Additional Review and Fees If this application requires a separate review by any local, state or Federal agency other than tfre Town of Vail, the application fee shall be inffeased by $200,00. Examples of such review, may include, but are not llmlted to: Colorado Department of Hlghway Acess Permits, Army Corps of Engineers 404, eb. The applicant shall be responsible for paying any publlshing fees in exess of 50% of the application fee. If, at the applicanfs request, any matGr is postponed for hearing, causing the matter to be re-published, then the entire fee for such re-publication shall be paid by the applicant Applications deemed by the Community Development Deparlment to have design, land use or other issues, which may have a significant impact on tte ommunity, may require review by external consultants in addition to Town staff. Should a determination be made by Town staff that an e)fternal consultant is needed, the Community Development DeparBnent may hire the consultant. The Department shall estimate the amount of money necessary to pay the consultant and this amount shall be foruvarded to the Town by the applicant at the time of flllng an application. The applicant shall pay expenses incurred by the Town in excess of the amount fonararded by the application to the Town within 30 diys of notification by the Town. Any excess funds will be retumed to the applicant upon review completlon. F: \Cd6AFORMS\Permits\Planning\Old forms\drb_minor_alL8-28-2007.doc Page 10 of 13 JOINT PROPERW OWI{ER WRITIEN APPROVAL LETTER I, (pri nt name)-B!\ I -Z!-eq-q]1 , a Jolnt owner of property located at lpo provide this letter as written approval of the plans daGd which haw been submitted to the Town of Vail Community Development Deparbnent for the proposed improvemenb to be completed at the address noted above. I understand that the proposed improvements indude: \Ari rub,eE$\A( r'6!6 € r.rSn,rtrr s totnr 6o\\e'r N)erh^z. ap-\-h<-lAe,trn er"*S 0 Lr Ptz'=TrlL Additionally, please check the statement below which is most applicable to you: D I understand that minor modifutions may fu made to the plans over the @une of lhe teview proffis to ensure ompliance wlth the Town's applicable codes and rqulations. ([nftia/ lere) D I rquest that all modifiations, minor or otherwle, whlch arc made to the plans over the oure of the review process, be brought to my attenilon by the appllant for addltional approval before underyoing futttnr rcuiew by the Town. (lnftia/ fiere) JblnfFrylty ounel /etter rcyid 1//84Md Er F : \cdev\FORMS\Permits\Planni ng\O{d forrns\drb_minor_att-8-28-2007.ooc Page 2 of 13 Slifer Management Company Prapery Management & Leasing_.*--* 0ctohcr 15. 2tIl7 'Ittryn ef Vgil Dtpanmmt of Communirlr Devclopment I I I S. Fnrrrtage Roud lVqq Vail. ('0 S1657 R*: Mastcrs Cnl|rn I'u \\'11'n1 lt h'lny Crrncem: I'lc.s-qc br rtlvtxtl that the Bouril of Dir+ctors of the Vail Villagc Plitra (lsndominium .{tsrxiation has appruved the tbllowing inrpror,cmorrs pmpr*d by thc Masters Cdleqv: I lnsrallntian of awnings io {ivc locttiors. The,r rvill he thr *rmc collrr !s r]re cxisting nr*nings, I Rcplucrtnr'nt of thcir mdn cnrry drxrr uith a nc* doer of thc rEsrc din*nsion*. Thc1. nrr rcplacirtg thc cloor sith s ner+sr vcrsion hccatr-lir ot.srfeq'md srcuritl r€a.son'. l-hc ncu' door nret$l will bc s hnrwn cnlor rhar will bcnsr ruttch thc nerr.railingr thst harc h€sn insrdled trcsr thc gollery- lllu tlottrcl of Direston trlicrc* that thesc gnopo*d chnngcs arr improyarrcnts tn the pmpcdl, thcrsfore we hape that thc Torrn t'rf Vail till upprrrvc thcm. 5inccrci1'. VaiI Vi|Iagc Plsr$ Cirndominium Ass+rsiation Ir>:;:2>fttS.- Stcr,c Stul P.O Our i?o{. f;rfud'dr. C{} f 16}l 0lOJ [d*.rr;[t Vilhgt Bixlevurl, Suirc G,106. Lx!*urdc CO $16!2'lilcplron*. {9?0} fi6.?!| | I Tclcfar. t970} 9l&?9lr tortnrrh'rll I crllr.d+c Form AO/CHI LTG Policy No. CT/.J273SZ5 OurOrderNo. V2'l35Zs Schedule A Amount $911.500.00 PTopeTty AddTess: CoNDoMINTM UNIT IO AND 15, VAIL VILLAGE PLALACONDoMINTMS 1.Policy Date: Name of Insured: October 03, 2001 ar 5:00 p.M. , MASTERS GALLERY AT VAIL, LLC, A COLORADO LIMITED LIABILITY COMPANY 3.The estate or interest in the land decribed or refened to ln this schedule and shich is overed by ,,is policy is: A Fee Simple fitle to the cstate or intemst covered by thh poricy at the rratc heneof is vestad h: MASTERS GALLERY AT VAIL, Lrc, A COTORADO LIMITED LIABILITY COMPANY 4- The land refemed to in \is policy is described as follows: CONDOMINIUM UNMS 10 AND 15, VAIL VILLAGB PLAZACONDOMINITJMS, ACCORDING TO THEAMENDED CONDOMINIUM MAP TTTNNEOE-NiaONOED OCTOBER 3, 1985 IN BOOK 426 AT PAGE609' AND THE sEcoND AMENDMENT ro rnE-eliBuDED coNDoMir.liuvr vrap FoR vArL vTLLAGEPLAZA CONDOMINIUMS RECORDED MARA:[2''iSSO rhr BOOK 525 AT PAGE 64I, AND ASDEFINED AND DESCRIBED IN THE comoortailliut*a oBcLeneuoN necoRDeD NovEMBER 19, 1984IN BOOK 4OO AT PAGE 2O2, THEFIRST AM;'I.6V-SNT THBNETO RECORDE DECEMBER 27, IgEgIN BOOK 520 AT PAGE 306, THE SECOND;M;NJIAENT THERETO NUCONPPO MARCH 29, IggOIN BOOK 525 AT PAGE 640 AND TTTE THTR' AMENOMENT THERETONTiORDEO JANUARY 15,I99I IN BOOK 545 AT PAGE 696. COUNT' Oi 'E?TE, STATE OF COLORADO. This Policy valid only if Schedule B is attached. _ Land Title Guarantee Compony Representing Chicago fiU" fn*.rrr"" Company 'l i Sign Application for Design Review DeparUnent of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 97 0.479.2L39 fax: 970.479.2452 web: www.vailgov.com General Information: All projects requiring design revierr must receive approval prior to submitting a building permit application. Please refer to the submittal requiremenb for the particular approval that is requested. An application for Design Review cannot be accepted until all required information is received by the Community Development Departrnent. The project may also need to be reviewed by the Town Council and/or the Planning and Environmental Commission' besign review apprcval lapses unless a building p€mlt is issued and construction commences within one year of the apprcYa!. Description of the Request: Location of the Proposal: Loh-Block:- SuMivision: Physical Addrcss: Parcel No.:(Contact Eagle Co, Assessor at 970-328-8640 for parcel no.) Zonlng: Name(s) of Owner(s): Mailing Address: Owner(s) Signatur€(s): Phone: Name of Applicant: Mailing Address: Phone: E-mail Address:Fax: fYpe of Review and Fee: tr Signs tr Concepu.ral Review tr New Constructiontr Addition D Minor Alteration (multi-family/commercial) tr Minor Alteration (single-family/duplex) n Changes to Approved Plans tr Separation Request $50 Plus $1.00 per square foot oftotal sign area. ilo Fee $650 Forconstruction ofa new building or demo/rebuild. $300 For an addition where square footage is added to any residential or commercial building (indudes 250 additions & interior conversions). $250 For minor changes to buildings and site improvements, such as' reroofing, painting, window additions, landscaping, fences and retaining walls, etc. $20 For minor changes to buildings and site improvemenb, such as, reroofing, painUng. window addiUons, landscaping, funces and rebining walls, etc. $20 For revisions to plans Design Review Board. No Fee already approved by Planning Staff or the JOINT PROPERW OWNER WRITTEN APPROVAL LETTER I, (print name a joint owner of propety located at provide this letter as written approval of the plans dated which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address noted above. I understand that the proposed improvements include: (Siepature)@ate) Additionalln please cheCk the statement below which is most applicable to you: D I underctand that minor modificattbns may be made b the plans over the aurse of the reviEw process to ensure compliance with the Town? applicable codes and regulations. (Initial here) n I request that all modifrcations, minor or otherwlse,.which are made b the ptans over the cource of the review process, be brought to my atEntion by the appliant for additional approual before undergoing further reuiew by the Town. (nitial here) SIGN APPUCATION SUBMITTAL REQUIREMENTS General Information This application is for any sign that is located within the Town of Vail. Specific requirements are available from the Department of Community Development. I. SUBMITTAT REQUIREMENTS A. Name of Business: B. Building name and physical address; C. Written approval from condominium association, landlord, and joint owner, if applicable. D. Type of sign (check all that apply): trFreestanding Sign EwdlSign IHanging / Projecting Sign [Display Box trDaily Special Board QJoint Directory Sign QSubdivision Entrance Sign tr Building ldenUfication U MUraI tr window Sign tr Sign Program tr Gas Filled/Fiber Optic tr Temporary Sign tr Other Number of signs proposed:Number of signs existing:- Sign message: Sign and lettering dimensions for each proposed sign (attach a colored scaled schematic drawing@%"=1'): Length of business frontage: Height of sign(s) from grade: Sign Location (attach a site plan and an elevation drawing or a photograph clearly indicating the proposed location of sign(s)): Materials and colors of sign (attach samples): Sign lighting plan: D Indicate type, location and number of fixtures.a Include height above grade, lumens output, luminous area. a Attach a cut sheet for each proposed fixture. Drawings showing how and where the sign or awning will attach to the building and how the awning will be constructed. The Administrator and/or DRB may require the submission of additional plans, drawings, specifications, samples and other materials (induding a model) if deemed necessary to determine whether a project will comply with Design Guidelines or if the lntent of the proposal is not clearly indicated. E, F. G. H. I. J. K. L. M. N. F: \cdev\FORMS\Permlts\Planning\DRB\sign-application-l2-05-2005.doc Page 3 of 4 12/0s/200s T{OTES TO ALL APPLICANTS Time Requirements The Design Review Board meeB on the lst and 3rd Wednesdays of each month. A complete application form and all accompanying material must be accepted by the Community Development Department prior to application Oeadiines. A schedule of DRB meetings and associated application deadlines may be found on the World Wide Web at www.vailgov.com. Review Criteria The proposal will be reviewed for compliance with the Design Guidelines as set forth in -Iitle 12 (Zoning Regulations) and Title 14 (Development Standads) of the Town of Vail Municipal Code' Desicn Review Boatd Meetino Reouirements For new constnrcUon and additions, the applicant must stake and tape the project site to indicate property lines, proposed buildings and building cornem. All trees to be removed must be taped. The ippticant must ensure that staking done during the winter is not buried by snow. All site tapings and staking must be completed prior to the day of the DRB meeting. The applicant, or their representative, shall be present at the Design Review Board Hearing. Applicants who fail to appear before the Design Review Board on their scheduled meeting date and who have not asked in advance that discussion on their item be postponed, will have their items removed from the DRB agenda unUl such time as the item has been republished. If the DRB apploves the application with conditions or modifications, all conditions of apprcval must be resolved prior to the issuance of a building permit. Staff Approval fne nOministrator (a member of the planning staff) may review and approve Design Rwiew applications, approve with ceftain modifications, deny the application, or refer the application to the Design Review Board for a decision. All staff approvals are reviewed by the Design Review Board.and any staff decision is subject to final approval by the DRB. F:\cdev\FoRMS\Permib\Planning\DRB\sign-application-12-05-2005.d0c Pagq 4 of 4 1210512005 oi- tr'ril fiflr"rrr r 'Qrrrrr fifiririr '(+rrr r r fu{rrrrr '(lrrrr r t: i\ i -t ii.i:i n AMffiRICAI.I AWNING CO. A llivision of SOLOHADO $TEEI., INC, ls:. gr.*$ ro: J1l1,1t-H'-tNhd" ti ntrr \il:io'J-' s :{r' pM., r',lhlT r.R(it,vt: fud-r_lfy''{r]sh.,rr" '-la*Bs*qeustr ITT-E F}-mbn-Enrlle, v&tl- . ulJjF*s'o .fl,X Ifi,{trS,iIIfTAL 4836 VAN GORDON iyTn.fll:I' \\THNAT RIDGB, COLOR{D(} 8(!U]:,1 (3rJ,i) 42i{'1iult FAx (3091 4::1-1t'{l? tri *.Eitd**kl -'-fJiltk t.'trrr.ltk-.h tr',F-, -fi SF-N"I\ t*tSt-- ,l-pf-il TD Y6-'l Frr,- lln.ira'-. s.,4.:f:,r.:+'{[L r.-:ii-, j iiii.r-- l"F$b t]flF{ n -tidJ-Aiy.li*ri,r' nl.Lf l'1, *&&):*a-.-*].--ljdi-k-' -''Pt*?'f{:'rt: ftsFL fnFF r' c}u- t,ttr qFl ltT -t-tJl* iF Ttn itArlE, l-lt'/ r-our+tsrtfs A+i\/{:p_ Lii"tEn0NK_. ku) ,r. j|" u{-F - r-tt'Jlt-l*bi!' Lr eilarrh ootr€,!-aL.)r\. ql)t)l . t; fu:a,:Lsls=-.1:iljd )rL-4!L*_P3{ft!C. I 'J'fi*."'s-*rjj*..- ,, l, JUL-25-S? Hn|'1 1{ : B5 AtrEri I !:Atl {i!'lN I Nr: aO 34 42.z94'L 7 F " 9r .f AffiHHlCAfrl AWNING COMPANY .hrs;,_-fi'-. r,_fi dlvi8l$n of OOTOMA{}O $TEEL, lNC, c,rr VAll.'r c","" Fl4tJar sr"r,"gt0t(Ab0 ,"ruk$,1 ***" _Se"k".- \$. ]rr,lbrosbrnr f,re{nk.r}q','. .nd F'k.c,o:-AU"$]*L-lrtqK.j$lA_},lfi1FSJf']j..-b.JU-SU1;_t ftrFJ f,t"l: n** -1*#rti]}is-" t-Ai-J"i;tY_: e,rt' J.i;''i An5f r1F,{M}1 t\F.lVF,. t. AIJFNS'(IMAT€ P!AHRTib INSTALLATIOi.i hArE 2. TB|S L.4tfrRACr lS SirDJ€CT fO AFIROVA!. OF ffi3to"rifj rob N&ftc 5AL{F:. r4 'EA*s OF PAYHTXTgairnre io ta grb fl fir,l to be in!oil.| oo ylst&llelon or |r t4+.,,]?sr, rlr!. Q. i0 !$f : tn {,{Jn Pqnro$! i ,, .- llJl|lxr'. l*rr.{ 'ar tXUoi{ Brind 6! Cr r\ nr3t $g'gJ 'i l. rn k tr t!.is| l(, r i. i i rrr n'.i x. ? d b, ury o. trsJt.r srorf TER SA O CONDIIIONS| ll€f'ure l$'t roir'61( a+ll3 lor mbde ! 9r9:'cooor. lt is ioi !(rbhct to c:',ijs|E1ron Nir€f tn{ jj dly pcrinr hr{ €i9iroi, }. xla lllTX,l;.r?t;1llTt'to ,.6crd Ddnlreor rccoroDtre -i,i ilrrsi ioi'riiii)fii iL"i,lvir ro r$rF{ c?rier,1 .nd nlrrrn.rrir. ,rr.!r i}r lt6 ? 4x c'nt'! t'J4'ngt a'l'c {rr.t .r'd-re'atod ir{ma ara sblal} to. '/!ft} a! r .!r1 !htri!, $cuer .roc! not r .t*t ut$!.3! tor nad t,3nrrgcr'4eirDrso/jsrrE.orhdrrhan,rterrI.,"rar6t,.rrd.d"ti*ii.i..niUriii",-.oo.+irrlyror6r.k{crror 4.,irn. ur r.r.,r:1;"j,1"1.'l,il'I1.,,ir crurrd br ,tAo .ar' oi c.runlrrtis. ;r :.'oi, iir ir:. iiio',i plcnr*.r lhar arouh6 rr3or,L,b.rr, ro.i?ar:.s,.r ,"",;'J,jrJ;?';,r:i:'"r'tnt|.cr ,s rcr.'r.6 io .n aitd.hly, or,rcr rcl.ci rs ps, in rdor|an 16 r:r orhe, ro,mt h4/.und.?. r rr"rr.n).{ ""., J"f l".Sl]rl'i.illll;u'!rrr:r dqc q'cd :n,rrid ur,rjr, rni |'* 6hrl bo leeeribio rr., rhr conrri4r rhari lnw bn {o^lrrrdd r r*rrl t li.tir:! tidl nol iJo hq\d i*n!$ '/jt dr'filcs lrr' dgh,, tn lhe gddormr^4e ot nc cortriar dla ro causcr Deton.r h,. .erlorirb* c,ja,,a, a".^tl;ii:f"' 'er"s l(1 r''il 'roEid n"i:'Fsl tJt,ro.o il ||1! casn Dirc. ji t!& rq |h. inrl. .r ihhrdalch upcrr .r.brllntt6r ernnrri.,j. "*r,JriJilr*r", rr,rr Filtnsn? ln n!1 rlnda wnrn d!*.6uyar agioo, ro p:y ip rhr.sn./ ht.r.rt qr tho ,ers d z1,f "'r, rn,ru,,:.,. ,!1. "'*.,*"Tli''1""1!i;:fiJ,',j,iii;i:::.T:L t"J bs r6stoh3'ibre o' r;abj€ r" an? lre'eri3r,ne coss vlrrer,oft. r..)r3 c, rer.\ir' ,^ -,.' -l irc f/sr'r1:ior. d:Frirrci, g, i.rrtlcd, Lin oi, Urlcn On krncretO $orl.rr)lj*,LFf ?loJra .i aaint,ng er [d]1rt!9 a.rrrr! rprciled abgva.i ! tr,r j !3.rr:i,r! i!|y.ae{rei b! tto,i in,r aiehDonaat|o. tna!/grce "".o'n* l! 4S36 VAll CCRDOI.I ST. " W|{EAT R|DCE, CO. 8(Xt33 r- rplt'A$t'CiLr 3{t3-{2a.79,t9 o FAX Sog-4?A-O{tI (tl\) ;$iJ[-.: 1.1$thfJ"].l*Eld- H':l-u.'" r,{$r4t a ':/-r|!6trhr 'wtllfE . uAliTlH trLg . yELtOlV - ACCOU nHCcFFiCE. pthk. CUFTOiIERCopy f #ErNa@ {dflt$ gt$'FqTi Fi.ilil 'F;-aij-it il'! tri*? 1* flnHlY t{Yeii{u'l i;i iifrl .tt',| -ri{;E- aFFz?"i ' { FP!r4 'raq'47 tA l*+rt!'' , ?5 i\ I !.i 1,./ -.J .," 4, .. " .4 ri' ,r -i -** "l?;rif u'f Ttr;Pqg*;- I 1,l i."1 .,-, fi i[ '' .- .l a!: a iI J,i s i ll,{:lil $" ,;i$i at 9i :l'.$ ".r i ?r- ::: 7.ri *l '*; ij.; l;*:'i-'; ,t-: L.'fi l - -..f-...,,^."rr" .,, ] i t', ?, il i I ,it."ii irli-rt".{' i l '..--.jj n=\$l-l-l' .l"r,j G., {,i <it '*) -'.-\--*yal ... In. - -\ir'+ niq-i5. aJ,F6-ri,iti-"iEi"F.E.:"If u1!'B'iY""4!*::-"::T?':**'""' 5i I cr. ::: c .r! !.U ifi ..\ $s$$ $m$q ;l,i;: t|t :,H1Ntl>J HrliltU3Nrt tl! t'l NOln iLg-92--lr_tl:t l!.E.Et! tgt J I.JIIIU g LLL:] :J YJ-J iTI:J s*rr"- IIIn - - ryrffi HT Aroe&gCF I I I It * - STANLEY i 5 rlin i" i='; t TECHNOLOGY ENGINEERING & PERFORMANCE Dura-Glide am and em sliding door systems cqnbi|E stateof-0|+an n icropfocesso. @mloSl wift a&ilced engineerirB to Foivile fe gfesl, lfict deFldbh nd hitEs- peilannte rhorqfuns in t|e i.rtusry bday. The Dua€lide Am and 300 S6i€s Erethe hdtEfy standrd b snodt r€liable operdin h every applicalicl ffir higlrMic r€tail bca- tiorE to upocab Fofescimal and iGtihrional s€nings. Dtra-Glide am and cm are cenified for Class 1 & 10 Clean Rmm apd ications. All cofipm€nB arB fully te$€d rnd preass€nrbled at he hdory Fior b $ipping. Preassoi$l€d lrader calpomrs ncan fast EuJbl€-trjee, Instrllatlar at $ejob site. . Microprocessor controller continually monitors door position. . Proven reliability with long-lasting cast urethane load-bearing wheels provides smooth, trouble-free operati on. . Adustable anti-riser wheels locks each door in its track. . Fiberglass reinforced toothed drive belt prevents slippage and uneven closing. . Advanced motion sensors, Stan-Guard'threshold sensor, and doonruay holding beam or Stan-Vision" video sensors, provide complete protection at all times. . Weather Wise* switch reduces opening widths on larger door systems to save energy in cold or hot weather. . Power-operated automatic sliding doors may be used as emergency egress doors because they "break-out" in the direction ofegress. The Dura-Glide 2000 and 30M Series meets the demands for use in Airports, Hotels, Hospitals, Supermarkets, Retail, Office Buildings, Public Buildings, Schools, Universities and more! HEALII.{CARE a.c6s Techndogirb RodEr Group 1 8(n 7 aCcESs (1 P0 722 23?7) AIRPORTS & HOTELS SUPERMARKETS OPTIONAT FEATURES . Class .l and l0 Clean Room rating for clean rooms and computer centers. . Wind Resistant Damper improves safety and STANLEY SU.1O() MOTION SENSORS Stanley offers the SUl00 as a standard activation system. The uni-directional function only detects approaching traffic to reduce the length of time the door stays open, pro- viding savings on loss of heat ard air corditioning. SAFETY SYSTEM DURA-GLIDE" 2OOO SERI ES DUM.GLIDE'3()OO SERIES :ttr reduces repair costs by wilhstanding wind gusls up to twice that of a slandard door package, . Transom Packages. . All-Glass Doors and Sidelights provide added elegance and beauly for upscale architecture. . Designer/utility package gives maximum design Rexibility with wood, hollo\ / metal, painted or full glass doors. . Access Control lets you add card readert electric locks ard panic hardware to limit access to reslricted areas. . Accesss Conlrol Consoles provide four modes of door operation - Timei Manual. one-Way and Automatic. . Etectric sotenoHilocidrig Sisirim utitizes a higtr f- torque stainlessst€el spring and tension spring. The Stan-Guardo threshold sensor and a dooMay holding beam. The Stan-Guard' and doorway holding beam detect people or objects in the door area and holds the dmrs open until the threshold area is clear. STAN-VlSlOl,l- uc rAr sunr/E rrnmE CAMTRA THAT AuroirAlts moRS (option) . Safety & motion detection in one sensor. . Continues b d€tect rnion u/hen door is inactive. . Computer configurable sensor zones. . Redundant safety zone coveraqe. . Buillin diagnostics. . lgnores panallel traffic. . lP64 waterproof rating. . Self-aQjuss to erwironmenbl changes. . Fail vfe operation if camera is obstructed, . opemtes in temperaures rangirE fiorn -30' to lS" F . ctrrino.ls safdy co\,erage a/gl vvfiile dooa is in mibn. NOTE: Ttansom Package Available fu both 20N & 3lN0 SerhsOFFICE & PUBLIC BUILDINGS RETAIT SCHOOLS & UNIVERSITIES AccessTechnoloqi€sPoduct Glcrp 1 8007.ACCESS(l 8$ 722 2377) _ HANDWAiE 'f, - HAXD TOo!S - FASIE II{G SYSIEMS - MECHAXTCS r00ls - AUTOMATIC DOORS f* The Stanley Works Access Technologies Product Group Customer Care: 1'8ffi'7'ACCESS fl .ffi.m.237n http://wv'rw stanleywork,com Dura-G I ide' 2000/3000 Series FEATURES: . All models available in bi-part (double sliding) or single slide configuration. BREAKOUT: (System is disabled when panels breakout) DG 2000 - External Sliding Panels 0nly DG 3000 - Full or All Panels greakout MICROPROCESSOR CONTROLLER: - Adjustable opening & Closing Speed - Aqjustable Distance & Speed of Breaking - A{usiable Reduced opening - Adjustable Time Delay - Auto Reverse on obstruction - Slow Soeed Search for obstruction DRIVE SYSTEM: . l/1 HP DC Gear Driven Molor . Twin 1/1 HP DC Gear Driven Motors (Optional) . Fiberglass Reinforced Toothed Timing Belt . Maximum Panel Weight - Up to 4001b (with heaw duty option) . Door Panels : Glass, Aluminurn Wbod, Metal or Cusbm . Speed Range: (based on size & weight 0f the door) - opening Speeds - ,5'- 2.5'per sec. - Closinq Speeds - .5'- 1,5' per sec. . Clear Door opening Typical width: 3' - 6' Door paciages are ctdqn rEnufactrred b fit ycurjob r€qiremsxs for sizes $€ater or flrE ller then typica l, contact you auttprized ganley Access Technologies Sales Repres€ndive HAUXP gZEr 8- (a3nm) high x 6" (lstnm) deep |WICAL llElGHl: 1 4" Q.lnI cler d@. openi.{ ot S -rl ' (2.1m) llP&dll44Dlt Slngle Slide 7'to v@.'lm b z?n). clear &o.openil4 wldfi otl6- f b fi -12' (Cl'lmm tolAF|l||r). Bi-Pat 10 b 1a' trtl to aznt, cle6r doo. oFning wilb d a6" b 72" (lfl fnm b l828mD up to 2m pounds e6dr omko DSMSys][fJd 1l1llP w, nrtoi ge{ drive, bdhed belt f4llnqlE& ntroplocessor bqsed, satuty logic. \ dbhdog I'f D sEt{sam-. 2 fr noaion (swildEble bet$r€en uni{irectiolal rid bi- dlrec{ma0 and I Slan{urd' and dolway holdln0 bean fo. sabty. S,t6n-Vlsion" DigilEl Video Cam€r8s odional. Mals, wdlFlaEs, rdio cmtd ootictal. g8E4(q.4 SX panel m the 2Un, Sx ad S0 pamh d| d|e 3m PA]fI8EdJBEalmUt^q s amps min. mIE COI'HIAME: ULcUI- Al'lsl A15410, UBC. BCA rcaO NIPA r01 Service & Installation Stanley Access Technologies designs, manufactures and nartets autornatic door systems worldwide. For more than 65 years, we have set the global standard for smooth, quiet operation, user safety, design flexibility. quality, reliability and ease o[ installation. Our service lorce is l,lorth Americas largest and nost comprehensive networt devoled to the installalion and mainte' nance of automatic door systems. This network combinss he global resources of Shnley wih the unmalched custoner responsiveness of localorganizations to ensure Erery door we sellsnd inst8llprovides our custoners with worry-free operation. for Service, Call Stanlev Toll Free: 1-800-7-ACCESS (1-800-722-23?7) IUAKE SOMETHII{G GREA'r .2m2 Aacess Techml@ies Prinhd in u.SA AT g?m 6m JOB NAME LOCATION DOOR NUMBER SHEEI - oF_ DURA.GLIDE 2000 BI-PART WITH ''0,' PANELS 1/4' $T SPACE STANLEY DOOR ENGINEERED TO ELEVATION PACKAGES ARE FIT YOUR JOB PACKAGE WIDTH INDIVIDUALLY REQUIREMENTS ELECTREAL- STAN-GUARD THRESHOLD SENSOR 3/4"(44) DIRECTIOML MOTION SENSOR F)oN € SIAI-GUARD EXIERIOR SAMPLE PACKAGE WIDTH INFORMATION rt)o Y(l INTERIOR EfiERIOR EMERGENCY BREAKOUT SLIDING DOORS ONLY q) t) N Y--l--+r-\- HEADER ABO\E 1, OETAILS NOT TO SCALE. 2, ELECTRICAL REQUIREMENTS: 1zOVAC, sAMPS MIN. TO OPEMTOR BY ELECTRICAL CONTRACTOR. 3. SEE APPENDIX FOR ADDITIoNAL lNFORlvtATlON. Et=EAEI-E98ldlJ4S PACKAGEWIDTH=2X CLEAR DOOR OPENING EMERGENCY BREAKOUT DOOR PANEL WIDTH = CLEAR DOOR OPENING + 23 3/E, -1/2 PA?K cE WIDTH - 11 11115" = CLEAR DOOR OPENING + 7 1/4" 1/4 PACKAGE W|DTH + 5/8" 6"(1s2) F.r.) r,-)c{ i- |r)c{Y INTERIOR z.z Lrjo-o E. LIJo FRAME IYIDIH ^41/2'('t14)'3 c{Y -l(o SEE APPENDIX FOR THRESHOLD OPTIONS oo l" N f|:) --l_\_ PKC. WIDTH NOMINAL CLEAR DOOR OPENING SLIDING DOOR/ PANEL NOM. WIDTH EMERGENCY BRFAKOUT NOM. WIDTH 10'-0"48"30 1/2'Jb 12'-O'OU 36 1/2'o6 t 4'-0'72"42 1/2'EO, Poge 1.1.25 SECTION 08460 STAI\LEY DURA-GLIDE SERIES 2OOO AUTOMATIC SLIDING DOOR SYSTEMS I. PART ONE GENERAL I.OI SUMMARY: A. Work included: Fumishing and installing factory fabricated and finished automatic sliding door system(s). B. Related Work: [Insert applicable sections including:]. l Section 07900 - Caulking 2. Section 08400 - Entrances and Storefronts 3. Section 08710 - Finish Hardware 4. Section 08800 - Glazing 5. Section 12670 - Entrance Mats 6. Section 16120 - Electrical Supply and Termination I.O2 REFERENCES: A. Underwriters Laboratories (UL), 333 Pfingsten Road, Northbrook, IL 60062, E47-272-8800, Fax: E47-272-8129. B. American National Standards Institute (ANSI), 1l W. 42nd St., l3th Floor, New York, NY 10036, 212-642-4900, Fax: 212-398-0023. C. Builders' Hardware Manufacturers Association (BHMA), 355 t exington Ave., New York, NY 10017 . 212-661-4261. Fax; Zt2-370-9047 . D. National Fire Protection Association (NFPA), I Batterymarch Park, Quincy, MA 02269, 800- 344-3555,617 -770-3000, Fax: 617 -984-7057 . E. Canadian Standards Association (CSA), 178 Rexdale Blvd., Rexdale, ON, Canada M9W 1R3, 41 6-7 47 -4000 ^ F ax: 4 1 6-7 47 -4 149. F. Boca Evaluation Services, 4051 West Flossmoor Road, Country Club Hills, IL 60478, 708- 799-2305. Fax: 708-799-03 I 0. G. ICBO Evaluation Services, 5360 Workman Mill Road, Whittier, CA 90601, 562-699-0543, Fax: 562-695-4694. H. International Standards Organization (tSO). I.O3 SUBMITTALS: A. Product Data: Provide manufacturer's product and complete installation data for all materials in this specification. B. Shop drawings: Show profiles, joining method, location of components, anchorage details, adjacent construction interface, and dimensions as well as all necessary wiring and electrical requirements. C. Samples: Sized to adequately represent material. D. Contract Closeout: Submit the Manufacturer's warranty and performance certifications [if applicablel. E. Installation Guide: Provide a written installation guide and/or installation recommendations, I.O4 QUALITY ASSURANCE: A. Automatic sliding door system shall b€ CERTIFIED by the manufacturer to meet performance design criteria according to the following test standards: [select, if applicable]: l. ANSI A156.10. 2. NFPA IOI. 3. Underwriter's Laboratories 325 (UL) listed. 4. C-UL Certified (equivalent to CSA certified). 5. ICBO (UBC Standard l0-l). 6. Boca (Boca Code Section l0l 7.4.3). 7. Qlean Room (Federal Standard 209 E, Class I). B. Automatic Sliding Door System: Shall be manufactured in an ISO 9001 registered manufacturing faci I ity. I.O5 PRODUCT HANDLING: A. All materials shall arrive in the manufacturer's original sealed, labeled containers. B. Store materials in a dry, protected, well-vented area. Report damaged material immediately to the delivering carrier and note such damage on the canier's freight bill of lading. C. Remove all protective materials after installation. 1.06 SUBSTITUTIONS: A. Proposals for substitution products will be accepted only from bidding contractors a minimum of l0 working days before the bid due date. The proposed substitution shall meet the performance and quality standards of this specification. I.O7 JOB CONDITIONS: A. Verifu that other trades are complete before installing the automatic sliding door system. B. Mounting surfaces shall be plumb, straight and secure; substrates shall be of proper dimension and material. C. Refer to the construction documents, shop drawings and manufacturer's installation instructions. D. Coordinate installation with the glass, glazing and electrical work. E. Observe all appropriate OSHA safety guidelines for this work. 1.08 WARRANTY/GUARANTEE: A. Manufacturer's Standard Warranty: Warranted materials shall be free of defects in material an workmanship for one year after installation. II. PART TWO PRODUCTS 2.OI MANUFACTURER: A. Stanley Access Technologies 65 Scott Swamp Road Farmington, CT 06032 t -800-7 22-237 7 (7-ACCESS) Local:860-677-2861 Fax: l-860-679-6436 Internet address - http ://www. stanleyvorks.com For local rep, contact: Sweet's Buyline l-800-892-1165 (#0202) 2.02 AUTOMATIC SLIDING DOOR SYSTEMS: A. Automatic Sliding Door System: Shall be Stanley DURA-GLIDE Series 2000. The system shall consist of sliding aluminum doo(s), sidelight(s) (unglazed), header, operator, and actuating controls. The system shall be completely engineered, manufactured and assembled by Stanley Access Technologies. All components shall be factory assembled in the header, adjusted and tested. No field wiring or operator adjustment shall be required other than the connection to job- site power and fine-tuning ofdoor speeds to compensate for various door sizes and weights. B. Sliding Aluminum Doors: Provide door units to dimension heights and widths with corresponding glazingas shown on construction documents [select one: standard narrow stile or medium stilel. Door holders shall be provided for all panels to control the doo(s) as they swing in the direction of egress. All door panels shall have security glass stops. [Please speci! as applies: Glass stops 114", 518" and t" shall be available for all door panels and transom.l All doors shall have intermediate rails. The bi-part sliding door system shall include a two-point lock securing the lead edges of the door stiles together and to the hanger assembly. The active sliding door shall be provided with a key cylinder on the exterior and a thumb turn on the interior in accordance with NFPA l0l. C. Door Operation: Shall be [select one or more: single slide or bi-part] directional operation. In compliance with NFPA l0l , the sliding door panel(s) shall allow "breakout" to the full open position to provide instant egress at any point in the door's movement. To allow safe egress, automatic operation shall be discontinued when the SX panel is in the "breakout" mode. Door(s) and sidelight(s) shall be sized to prevent pinch points at meeting stiles. D. Aluminum Frame and Extrusions: Shall be a minimum .125" wall thickness in integral structural sections. The frame shall be [select one: standard 4-112" deep section or 6" deep section]. The bi-part transom packages shall contain one vertical transom tube. [Specifr, if applicable: Provide additional vertical tubesl. E. Aluminum Extrusion Finish: Standard anodized finish shall be [select one: AA-MI2-C22-431 Cfear, AAMI2-C22-A44 Dark Bronze or Blackl. [Special and painted finishes are available upon request. Speciff color finishl. F. Sidelights: [select one: fixed 'O' panel or 'P' panel] Provide sidelights to dimension heights and widths as shown on construction documents with conesponding glazing. All 'O' panels shall have intermediate rails. G. Header Case: Shall be 6" wide by 8" high (l52 mm wide by 203 mm high) extruded aluminum and capable of supporting bi-parting doors of220 pounds per leafover a span of l4'-0" with minimal deflection. lt shall contain door operator and door mounting components. The header cover shall have a continuous selflocking hinge to open flush with the top ofthe header. H. Door Hanger Wleels: Shall be 2-112" (64 mm) diameter urethane wheels with precision steel lifetime lubricated ball bearing centers. The sliding door(s) shall be held on the track by 2" (51 mm) diameter anti-riser wheels and supported by a factory adjusted cantilever support and pivot assembly. This assembly shall allow the sliding doors to swing outward for emergency egress without the need for a lower door pivot support. The door height shall have an adjustment of 1/8" +/- as required by field conditions. I. Door Operator and Controller: Shall be the Stanley Dura-Glide System driven by an electro- mechanical operator and a regulated electronic conholler. The operator components shall consist of a DC permanent magnet 1/8 horsepower motor, gear reduction drive, Stanley Pozi-Trac position encoder, and a microprocessor control box. Provide 120 VAC, 5 arnps minimum to electrical door operator. J. Microprocessor Control Box: Torque shall be factory set as prescribed by ANSI A156.10. The control box and Stanley Pozi-Trac position encoder shall automatically set the opening and closing check positions, and the full open and full closed position of the door system. K. Threshold Sensor: Shall be the factory installed Stanley Stanguardil Threshold Sensor. It shall be a selfcontained fully adjustable sensor system that works in conjunction with Stanley SU-050 motion sensors. Simultaneously with the door opening signal, the sensor shall be energized. It shall emit a 30" deep by 72" rnaximum wide elliptical shaped infrared presence zone centered on the doorway threshold line. The door shall close after the SU-050 sensor and Stanguardru threshold sensor detect a clear surveillance field. L. Motion Sensor: Shall be the Stanley SU-050 Motion Sensor. The unit shall be switchable between bidirectional and uni-directional k-band frequency to detect all motion, fast or slow, in both directions with a relay hold time of 2-30 seconds. The Stanley SU-050 shall be mounted to the header 10'-0" maximum above the finish floor. Using the adjustable antenna tlre detection pattern shall be semi-circular, approximately 7'-0" wide by 5'-0" deep for a wide zone and approximately 6'-0" wide by 8'-0' deep for a narrow zone. The location of the detection zone shalt be adjustable from the face ofthe door (20 degrees to 35 degrees in increments of3 degrees). The unit shall operate between 30 degrees through 122 degrees F in all environmental conditions. The supply voltage shall be 12-24 V AC/DC +/- l0% and the power consumption shallbe6Wmaximum. M. Safety Search Circuitry: Shall be provided which will recycle the doors when an object is encountered during the closing cycle. The circuitry shall search for that object on the next closing cycle by reducing the door speed at the position the object was previously encountered, and will continue to close in check speed until the doors are fully closed, at which time the doors will reset to normal speed. If the obstruction is encountered again, the doors shall come to a full stop. The door shall remain stopped until the obstruction is removed and an operate signal is given, resetting the door to its normal speed. N. Accessories: The Dura-Glide 2000 automatic sliding door system shall have the following accessories to reduce enerry loss: Adjustable nylon sweep(s) on the bottom of the sliding door(s), double pile weatherstripping for the sliding door lead edges, single pile weatherstripping between the carrier and the header on the lead stite(s) ofthe sidelight(s) and the pivot stile(s) ofthe sliding door(s), and a selector switch located on the interior side ofthe unit to allow doo(s) to open at full or reduced width according to weather and traffic conditions. [For clean rooms, delete standard pile weatherstripping and insert: For clean room applications, weatherstripping shall be rubber vinyll. [Insert, if applicable: Provide automatic locking system, hydraulic closers, battery packs, alarm contact monitoring thresholds]. 2.03 OPERATING CONDITIONS: A. Climatic Conditions: All automatic sliding door system components shall operate between -30 degrees F and +130 degrees F in all climatic conditions. III. PART THREE EXECUTION 3.Ol INSPECTION: A. Veriff that the automatic sliding door system installation wilt not disrupt other trades. The door installer shall verify that the installation area is dry, clean and free of foreign matter. Check as-built conditions and verifu the manufacturer's automatic sliding entrance system details for accuracy to fit the wall assembly prior to fabrication, Report in *riting to the Contractor any detrimental conditions to the proper functioning of the automatic sliding entrance system. Installation shall proceed once the unsatisfactory conditions have been corrected in accordance to the manufacturer's recommendations. 3.02 INSTALLATION OF AUTOMATIC SLIDINC DOOR SYSTEMS: A. Installation shall be by an installer approved and trained by the manufacturer in strict accordance with the manufacturer's instructions and fire marshall's listing requirements. B. Comply with the automatic sliding door system manufacturer's recommendations and/or installation guide when installing the automatic sliding entrance system. Set all units plumb, level and true. C. Provide all fasteners required for installation of the automatic sliding door system. D. Adjustment and Cleaning: After repeated operation of the completed installation, re-adjust door operators and controls for optimum operating condition and safety. Clean all metal surfaces promptly after installation. E. Explain and review the Daily Safety Check Procedure. END OF SECTION OE46O t -,- Aufomqtlc Enlronccr - r Colorodo Brqnch of FF_ Slonley Accegt Technologlcr, tlC J III @ oo1/o04 274W.Iffi Avcnue Dcnvcr, CO 8020t1 Denver Phonc - 38.623.553? Denvcr tox - 3O3.6296125 Coforodo Spdngs - 7 19.18.0121 Ft. Collins - 97G184-9|5l Yoil-97*179-73n Cheyenne - 307-€&9800 9704774600 97M?7-060r lgzl7? TO: RAYLA CO}IIAITy: MASTERS Gfi:LERY ADDTESS! IOO E. MEADos,s Dn, Jor HA E: AuToMATrc SLTDER I.EADflXE: 5.5 wEEKsFrouDATaoFAPPRoVAI, D^Tu Alfr00ll Puol'rE IilutrlEt: trAX NUIITEI: JOI ADDTESS: PROPTO$Atl: We herebv nrbrnit soecificotiryrs ond eslinofes to: Fumish ond Insfoll: I -Sfanley2m0 Duroglide, Aufromqlic Sliding doorrryifh Dork Bronze Finish, lo fit l0'0" x 7'5" opening, fwo sels of phofo beorrs for sofety ocrcs eoch opcning, ond $ondsd ,\,1S hook bolt lock. 2 - Optex 202 Unidirecti,onol Moflrn deteclofs with threshoH detection- HCf,UDES CtAitS & ClAZltc Incbdcr: htollofion of lisled equlpment, Teor ouf of existing, One yeor pcts ond lnbor wmonly during regulotr.rines houn. Elctdcc Prepored oper$n96, I IOV ows to ooralor. wie orrd whe rutlinS. Any p€rmih if recpied. Bonding b nof included in thb proposol. ff bondiE b requied ii con be provirled ot cost drJs $100.00 oig{nolionfee. FtE sE NotE: All coNrnAcrs AND tEcAt DocurttE]trs ruir !t FsulD To @ PUASE ilAll rO OUt oCl{VEn OffiCE, WE wltt K)rSAtD flt! DOCI ff:X|3 rO OUt CO|?ORATE Olr|CE FOt nOCEttnF. wc trdofty proFce to firnbh molsld drd f$a- complota h ecqdcrcc vilh ttrc <$ryc +cffco{fors. FhtcThorlglprdfi.ur HuM tlll*tan IbIIst &, M JaSe Strtfh Nofel lhb proposol moy be withchonvlr by uc ff not orcepted wilhin 60 dqy: ond obove prioa h bosed on the terms cnd conditlons of AIA lorm A,l0l subcontrocl ogroenrcnl. Poge I of 2 @oo2/004 CondfficnsAcceplorreof lfiBofrerbyfhepr*rfiarer$of conslflvte on&ranctclrttoctlorlt:cpwclw*of lhe lfems descrfbed tpreh. we 9ro[ nol be loble fo lfe non-pilunrcrrce of tlrft con rrccl tr, vltwts' or tn pil| it such nonf€rbtrnonce ir fhe psulf of ony cd4tse q cousstr beYpid ow reg6r,nabE' carrlrol, includng {but wlthout limllclion by rcoson ot enrnwulkutl fhe folowtngr fres, srrlkes, diittarences $th ernpb4€ei, cosssltb+ deloys h tron9Portottori, shortoge of c<rr, grrt/enrnent redrfcJtono or offercouses nordrcil lhese excepfilrrx be Enrited q vrciv€d W ony olfier lerms of the contoct, wlreittrir prf'rrted ix wrtlten.Ierras net 3O do6, sugcf fo lhe opgovd d ou qe<ifil depolmqrt, Foge$ blng6 nnde ,o nrpprt goFcf reqdcments $dil be rnrrpb€d $,hen opp#cabb ondsuf,liecl folfie sorne nennr trr Jte evenf itsho[ becorne necesoryfo.stonleyAccess fecfinologder, llC fo enforce orry d Itlc pavldons of tlrts ogreenrenf, ptrchasrr q,ees lo poy oll costs onC expenses ostoctttfied with such err/tcenrlt ttcntd*pvttlhotn fufi/lg1rton lhe fee of o colectirn ogency ond on dttonFx aice oborle ercludessbs tor. use ftrr, rqpficobb, hosbeer] irrcrdad inorguole. Ftw Ttownd *wr E n&d ftirffi lroUtrs A, Wl S,7I3.(M Il$ rcilottto bc cocp|rhdbf crlrbmr- l|E Jgn orr dthr fforhg oglclr l.Nrre(hlrt)l Irds lo '3 '7- procccd lllrft prqf.dof ftG prlccffcdnbovr. cor*ocfr orpfrcln . orddr" $gn rtrrt ,,(\-rr., uLu uaa-- Slgndtrrl mutf tsftd nr rrtrorryto J3n Lg;Ct lHrg.lostm.ril!. OB 2. l.loms Dote: lwil be h.ftgo ccnhoctor PObosGd upon lhbquote. Pop 2 of2 _:AeeE€€brrJ TECHNOLOGIES DUR/A-GIIDE 2000 rtrrlal iimportanti ltlltttltlrtlltllll TRANSOM PACKAGES REFER TO PAGE 10 2@590 C &95 Installation Manual 2OOO CONTENTS Basic package installation is in suggested order of execution. Baslc Package Data (1) Masonry Opening (2) Assemble Headirr/Operator to iambs.(3) Install Header/Operator and jamb assembly. (4) Install (o) Panets - Inslall K6y Strip - Holding Beam Leads (optional) (5)'lnstall (SXl Panels .. ""''-Frep. wtieel positions - Insert bottom roller - Hang panels on track - Adlust panel heighl, lilt - Adjust anti-risers - Connect panels to belt - Manually slide & set bumper stops - Bi/O detents - Adiust door holders - B,/O detents - Adiust SX pivot - Ad.iust bottom sweep APPENDIX-Transom Package APPENDIX. Fasteners APP EN DIX-Jambs-By-Others JambTemplate DURA.GLIDE COMPONENTS 1. 2. 3.' 4. 5. 6. 7. 8. 9. 10. JAMB (2) HEADER END CAPS (2) O PANEL (2) BELT TENSION ADJUSTMENT IDLER PULLEY HANGER END CAPS (4) ANTIRISER ADJUSTMENT (4) DRIVE BELT BELT CLAMP BELT BBACKET. LONG 11. LOADWHEELS(4) 12. INTERFACE BOARD BOARD 1S. HANGER-DOOR (2) 14. BELTBRACKET.SHORT 15. SXPANEL(2) 16. CONTROLBOX 17. WEATHER STRIP (2) 18. MOTOR/ENCODER 19. DRIVE PULLEY 20. END STOPS (2) DURA-GLIDE BI-PART HEADER-OPERATOR ASSEMBLY r/6" Erd0ap 1a'End Cap tr trtrE GENERAL PACKAGE D End Cap Mounted End Cap ltlounted Wifrt (opnor.rnr-) Jambs 1/6'Endoap Surfae Mounted Wthout Jambs BhPART PACKAGE W|DTH INFORMATION (WO JAilBS) Yr'Jarnb End Cap t76" tr tr r-- o -rit- tr tr tz6'End CaPtI trtrtr DOOR PKG PKG WETH suDrircDooR OFG" {sx)DooR WIOTH (P) PAiTEL WIDTH (qPA,NEL w|om t ooR TRAYET t Asol{RY OPEMl{G CAULKII{G ALLOIIVANCE 28 9'-81/|I 30%e"&7Ad 3M{2{g'-w1:l6"islDE m 11'S1E 60 36q//'d'$74{367rei'3€r 11',-$tt',r,t'lSIDE nTz 13',.€1,"7t 4Ht{427/t{48t{36"13',87a',l,"ISIDE STNGLE SUDE PACT(AGE WIDTH INFORMAnO{ WLOCK JAilB Oi{LY) DOOn PKC PKG WIDTH SUDINGT'OOR oPci. (sx)DOOn wrDTt{ (P)PANET WIDTH (o) PAI{EL WIDTH IXx)R TRAVEL IASONRY OPENING CAULKIIIG ALI,,OWANCE m36 6'-1O1/a"351H'4174{41Vr{4174e"#w'6',-lo%"%,TOTAL M2 7',-101/{4118 4V/r{47eAa"4VAd 411,,d,7',-10%'%"TOTAL M 8'- 41/a'41h',5074d 5@/r{fi74{$Uz"a',- 4W %'TOTAL m4 8'-101/{471H',5374e"53%C'5374s"471h"a'-10%"%"TOTAL 3 GENERAL PACKAGE DA Hoader/Operator Pkg Height Bus tZ*" Finished Floor PACI(AGE IIIOUNTED IN PREPARED MASONRYOPENING MASONRY OPENING '| Check Floor acroes enlire op€ning. 2 Fi[ arry lolv areas to levd corxflion 3 Allou, for S€, terazzo, etc., ution d€termining finished floor. l-bad€r/Oporalor PACKAGI SURFACE MOUNTED DUREGUDE 2OOO INSTALLATION PROCEDURE M.O. WDTH Std.Door gzstd. FINISHEDFLOOR SURFACE MOUNTED TO WALL WITH P-PANEITS (BFPart, No Jambs) Bolt Header to Ailodor Wall 1 . l-leader'Must b€ Level 2. Header must be at Conect Fl€ight from Highest Point of Floor in Opening 3. Mounling Holes should be above and below header nul kack 4. Plan wirirE route for 117 VAC inlo Header 5. Be Carctul dwires ard operator comporcnts when driling. SURFACE MOUNTED TO WALL WITH P-PANEL (Singte Stide wtLock Jamb)Header Mounting Holee Assemble Heador to Lock Jamb using 7e-20 Screws in Jamb Riv Nub. NOTE: JAMB LOCK SLOTS ARE TO EXTEBIOR OF ENTRANCE.NOTE: JAMB LOCK SLOTS ARE TO EXTEBTOR OF ENTRANCE. Rode Doorway Holdng Beam cable into Head€r thru End Cap. Plan wiring route for 1 t 7 VAC into. 9Z Srd. Height 1. 2. 3. 4. 5. 2. 3. 4. 5. 6. Faden Jambb FhorCliD. ANO HEADER, JAMBS INSTALLANON 1 . Check Floor Elsration across €ntire instalatltn area. Make allowance tor any tloor finish. Fill in lotfl areas. Header m|,Jst b6level. Hgader. Locale Jamb mounting clip. Be sure jamb is plumb. Sedlre dip to floor. I-eate Highest Pcint o/ Frool in op€nirE and l6v6l and staight edge. Fastgn H€ader lo wall. Be sure header is l€vel. Mounting Holes shonld be above ard belo$/ header nut track. Header heQht muS be measurcd trom hQhest point of floor. lf Fact'cry Jamb(s) are to b€ used, secure to header with )rrivnuls and scrervs prwiled. See "fasteners". .r ;; 't'.il Highest Pcint of Floor Jamb Mtg. Clip By Others End Cap ltlounted Application fl iambs are us€d, swing assembty into openirq and ':: fasten iambs to M.O. shim jamb6 for h€ight and plumb. .f End Cap Mounted WthoutJambs Hea&r is mounted directly b M.O. or to jamb€ (by oth€rs). Use Header mounting templaiBs (Attach€d) to drill holgs for appropriate tasteners. Shim between erd caps and M.O. for snug fit. Install 1 17 VAC Power through l-l€ad€r End Cap al connec'tor board end. OorP PANEL INSTALLATION PROCEDURE 1. Set panel in onlrance, Plumb and mark floor. 2. Fasten key slrip to floor, 7e" in from ma* and 3. Set panel on key strip. Feed holding beam and Top Rail Seated Against Header Lb mountng screws. _TorqueTub B/O HoldirB Beam Wire Feed Thru Carefully %e'adhesive Floor Mark Foam Strip ----.r{ KeySlrip "O", "P" Panel O, P Panel Stile Breakout (Spring Actuates Switch) 2%e'lrom jamb. B/O swilch wir€s lnlefior from lead stile up through header torque tub€.. Be sur€ panel is in pfoper position. (Flumb and tirmly against Fmb). Clamp panel againsl Header liP.clamp panel agalnsl Header lp. On bi-parts two bottom rails must be aligned b fprovide prop€r mseting of SX stiles. Drillthrough holes in header lip into panel. For #B-18 pan€l l-T- %G+ Hef. 4. 5. 6. 7. TNSTALL (SX) SLTDTNG PANEL Insert bottom guide into SX panel (as shown) Remove bottom guide retaining bracket (not shown) from O panel, reinstall after the bottom guide is captured in the O panel. Load Wheel Anli-Riser Wheel Loc€n nuts and adius{ load wheels to lowesl poeition in hanger. Tighten load wh€€l nuts. This adiustm€nt will sot lh€ parEl to its hiohest oosition-to ease botom quide iniertion anct keops antirisers frori interfering while hanging panel. FIGURE 16 Anti-Riser Wh€el Head€r Track Hanger ll t t Lift Pan6l Lilt panel up orcr (in dircction of header track) and <lown. FIGURE 17 ADJUSTSX PANEL(S) 1. He(rtrt adjustment. a. Loosen load wheel nuts ard lurn with hex key b. The g6p between SX panel(s) and threshold is adjustable lrom 1/1i' lo U2' c. The load stile(s) sfiould rEet with m gap top or bonom, Bi -Part-meet opposile SX panel. Sirple slide - meet jambs. d. When adjustrnent is compl€te tighten load wh€sl nuls. 2. Anti-Risers a. SlkJe anti-risers up in their sbts 16." to Y3a' charatrcg to tack. A matcfi book cover inserted belween wh€el and anli{iser track makes a handy gauge. b. nghten nuts. -cAuTtoN- For Prop€r Adiustmenl Use: qHEX nut for locking .ALLEll for h€ighl adiustmenl only .CI{ECK OAP at anli-riser AFTEB linal tighlening 1/1lo 1E Gq 1fu'-1hy''Cbaarre No Gap, Stiles Paralel Anti-Riser Track Anti-Riser Wheel FIGURE 19 FIGUBE 18 INSTALL (SX) SLIDING PANEL 1cont.) Fasten belt brackets to hangers. Left Hand Single Slide ..need adiuslment. Break Out Detents are factory set to average requirements. lf more or less breakout force is required (up to 50 lb. by code): a. Break out panel. Remove end cap. b. Loosen (2) detent block set screws c. Slide detent block from hanger d. Adiustdetent e. Replace f. Be sure detenl block lines up with clearance slot in door. NO!E: The glazing rnaterial in both fixod and sliding panels of all ElHlng doors sftell comply with tho requlrern€nts in tho psrfornance sp€cilications ",nd melhods of l6st for safety glazing materbls us€d in buildings. ANSI Z 97.1 - 1975 Right Hand Slngle Sllde ,.oF Bumper Stop lir ruur FIGUBE 21 lf the belt is set too tight, gear reducer or bearing failure can result. Remember that this belt drive has a long span so some deflection is normal. Symptoms of loose belt: - belt hitting header, especially on recycle. - drive pulley skipping on belt teeth - belt almost "climbing'oul of engagement: vlith dfive pulley on opening cycle. FIGURE 20 Screws .rrr Bclt Tendon B€lt lension is factory set and should not iilt FIGURE 23 BOTTOM EXTRUSIONS KEY STRIP SX PANEL SAG ADJUSTMENT DOOR GUIDE ROLLER SNLE ADT,3I!R BE SURE TO HAVE GTASS IN PLACE BEFORE ADJUSTT]IG. BE SURE TO HAVE GLASS IN PLACE BEFORE ATUUSTING. 1. SWING PANELTOABOUT 10'OPEN. 2. LOOSEN DETENTI.ATCH ONHANGER. 3. LOOSEN PLASTIC CAP ON I.IANGER 4. ANUST CAP SCREW (ALLEN WFENCH) FOR PROPER PANEL CONDITION (NO SAG) AAtSrt TOP VIEW OF SX PANEL 5. RE.SETLOCKNUT. 6, RE.ALIGN SX PANELWTTH HANGER. THIS IS BEST DONE WITH THE PANEL SWUNG OUT TO 9(F 7. LOOSEN PIVOT BAF SETSCREWS, SLIDE PIVOT BAR IN HANGER FORALIGNMENT. FROI{TVIEW RETGHTEN SET SCREWS. SLIDE DETENT TC) ALIGN WITH "IA/NDOW'. TIGHTEN. REFASTEN Pi-ASTIC HANGER CAP. L 9. TRANSOM PACKAGE IMPORTANT lnstall alf gldss extrusions,27,28 29, gO, in the transom tube and jamb tube beforc assembling the frame. These extrusions can not be installed after the frame is assembled. !,t. q|.r?s I trl' GLrtiSS ffi tiln'otrfuaE3 -, 1r4' cL st orata olatt REF l.,lo. NO.PATTNO. (NEW) 21 22 23 24' 25I.n 28a 30 31 32 3t' 412858 313450 313,160" 412859 412860 712794 413060 41s06'l 41310{! 4131fif 412861 4128dt 4124@, JAMB EXT. TRANSOM HDWE TRANSM TUBE HDW TRANSOMTUBE EXT ]NSERT EXT. GUANGGSKTEff 1/4'GtS STP ADAPT l/rfGLS STP F(T. SAGLS STPADAFT 5/8'GLS sTP EXT GI.ASIS STOP Dff. GUTTEF O(T. GUTTER EXT. 10 @-fi +-j +is l tAY I I DURA-GLIDE' Headcr EllD BRACKET Template (Lett Hand, when viewed from cover side) 11 I I_l Iq I I+ I I I -!-A\J-l Its-- I I Iq DUftA-tiLlDE" Hoader END BRACKET Template (Rlghl.Hand, when.vbnred front cover side) 12 ; {f Design *eview Board ACTIOI{ FORlll Depertment of Gommunity Development 75 South Frontage Roa4 Vail, Colorado 81.657 tel: 970.47S.2139 fax: 97$"479.245e tryeb: rvwtrr,va i lgov.cwn I mffiffiffirl oat*r*larY €rE[rF|GRT Project Name: Project Description: Prcject Address: Legal Descrlption: Parcel ilumber: Comments: nat{ctt {r.X^y DRBNumber: DRB020097 Awnings Participants: OWNER Paul & Bonnie Fiegler 100 E Meadow Drlve #27 Vail, CO 81657 APPUCANT Paul & Bonnie Fiegler 100 E Meadow DrNe #27 Vail, CO 81657 1OO E MEADOW DR VAIL O4lLilzOOZ Phone:,177-0500 MILilAOOZ Phone: 477-0600 LocaUon: Masters Gallery at Vail L.L,C. Lot: BIocK: Subdivislon: VAIL VILLAGE PI.AZA CONDO 2101-082-5601-0 BOARD/STAFF ACTION Actionl @NCEPT Condltions: Condl 200 A conceptual review is NOT a Design Revierar Board approval. Plannen Bill Gibson MRR. 15.208e 5! eAPt'1 N0. 596 P .1,/4 Application for Deslgn Review Department of Community Development 75 South ftontage Road. Vail, Cdondo 81657 Ef : 9il.479.2139 taxz 970.479.2452 rveD: wwwd,vall,co,us General Infprmationi All Projects requiilng design ranlaru must rcceive appmval prior to subnitting e building permit application, Please refer to the submitbl requlremenb for the particular aFproval that ls |Eque5ted, An appllcatlon for Desgn Review cannot be accepted untll all rcqulred Inhmration ls receh/ed by tie Communlty D€veloprrert Depafinent. The proiect may also need b be revlewed by tfie Towtl Coundl and/ar the Planning and Envircnmenbl Cnmmission. Design reuiew apprwal lap6e6 unls s brlldlng pc}mft ls lssftd and conslrucEon comnrcnc witfiln one yesr oftlr€ appruuat, oescrlptiorrofthe Requests - ?tn N 7r ttttt,s- Laatim of tfie Prcposal: Lotl. Blod<;Subdivisiort; PhFicalAddrcss: (Conbct Eagle Co. Asscssor Et 970-328-8640 for parcel no.) > Utz Name(s) of Owner{s}: owne(s) Signault€(s)i tr New Cmstrudion 9650 For aonsbuction of a new building or demo/rebulld.D A'ddition F00 For an addlton wtrere square ftiuge is aiOeO m any residential or tr Minor Atterarim $2so HIfr,H':nx?ii'I'J lf,ljfi,,:flJ!fl5i1;,hiffiffi,TlHTi:'o'(muftj-famiV/commerclal) reroofirg, pairirng, windon addiuonr, -landscaplni, fences and tr Minor Attmtion $20 #illffirTt llfuH to buitdinss rnd ste improvements, such as,(single'family/dudex) reroofing, pairrdng, windonr dditions, landsapini, fences and El chansee toApproved Ptans $zo ff'Hit'ifilte%ns atrcady approved by prannrng starT or the tr separad'n Request No Fru DtdEn Rfl,leu' Eo6fd' ForOfnse Um Only: Faa DaL{.ch€ck No,:_ Byi Application Dete: Plannen DRB No,: Projed No,: P ,parcel No.l 46ffib,_ Nameof Appllcant;&" tte-'2u.4€l2_ E-mail Addreso: _ Fax; rYpeof ReviewandFeei -..\ { Bo-*signs CD *f-*r.**qutsreborortrErrsrsnarea. Conce@al Review r{o-fee Malllng Addrecsl l\0.596 P.3/4 SIGTI APPUCATIOII suBifiTTAL REQUIREHEilTS Genenl Inlbrmauon Thb application is for arry slgn dlat ls loeEd wfriin th€ Tol ,n of vall, spectfic requlrerfienE are available ftom the Departmnt of Cornmunity Darelopment. I. SUBHTTTAT REQUIREI'ETIIIS F F, .z=---\(G, j f'l}f\o K. Ai/l L, t4RR. 15.24@ 5ralfl"l Building name and physicalrq!! Wrften appwal @condomlnium mlatbddndlord, and irint orrner, if apptbble. Type of sign (check all that appv); DFt€estandinE Sign trlUallSiqn Xirangins / Pmj€dine Sisn QDlsplry Bor trDaily SpeclalBoard QJolnt Dlrecbry Sign QSubdivision Entanm sign A, B, c. D. Itlameof Busircss: /il+e$rte 6n^n=P,7 zq-\ lFrr.'. E Buikfitrg ldentillatlon tr Munl tr Windot, Sisn tr Slgn Program D Gas Elled/Hber OptJc B Temporary Sign B Other Numbcrof$gnspropt*dt - L NumberofsignsexistjnC,--&- "*n#J#kfuffig,f# SIgn lighting pl8n: o Indicah type, loeton and number of fxturcs.o Include helght rbove grade, lilnens ou{put, luminous area.tr Attach e cut sheet for eactr pmposed llxture. M, Drawlngs showing hory and where ttre sign or awning wiil attedr b tire buiHirrg and hon the awning will be constsucted Sign siEn and letGrfng dimensions fu eadr proposed sign (attach a colorcd scaled schematic drawing@'ao=1'): Lengrtr of buslness fror@e: (- | ^ , 'n Ffeight of sign( s) lron Era&:_lJ 9iA Sign Location (attactr a slE plen and an elevetion drawing or indlcafing the proposed location of sign(s)): Page 3 of4/01/10/02 ffi Questions? Call the Planning Staff at 479-ZL3g T0}ts srGN/AWNING APPLICATION This application is for any sign hat is located within the Town of Vail. are available from the Departnent of Community Development. {;t-i,i,^J-\.{ G*ur-ce-f Specific requirements A. c. D. E. F. MME OF BUSINESS:Y r,l BUILDING NAME and ADDR€SS: CR.T.,g;U,\O.:(-t'!ir\-E3.- MAIUNG ADDRESS: OWNER(S) SIGMTURE(S): H.NAME OF APPUCANT: (Llt ii Dr Arcc- pHySICALADDRESS: iilr tt r,,rrtr-oo.., Ci Atzl- TEGAL.ADDRES'. ?U "T PHONE: _17/ -/A43 PARCEL# "ift*8i6at+€ (Contact Eagle Co. Assessors ffice at 970-328-8640 for oarcel #) NAME OF OWNER(S): it-t,raaC t11raca--> pHONE: Li27-l ttz TYPE OF SIGN (see next page for definitions):o Free standingE Wall Signtr Hanging Sign NUMBER OF SiGNS PROPOSED: i tr Sign Awningo Other, specify: NUMBER OF SIGNS ECSTING: iJ. K. I M. N. tl SIGN MESSAGE: 5,Ar,iur,rr 6Artr,n-'t - t\^-f-r 'Vt l-\ Ic I SIGN AND LETTER]NG DIMENS]ONS FOR EACH PROPOSED SIGN (Attach a schematjc on 8.5" x 11" paper): LENGTH OF BUSiNESS FRONTAGE: HEIGHT OF 5IGN(5) ABOVE GMDE: 1, 2.. SIGN LOCATION (Attach a site plan and an elevation drawing or a photograph clearly indicating the proposed location of sign(s)):trii'frf t w rl-iilLl?\ P. a. R. MATERIALS AND COLORS OF SIGN (Attach samptes): DESCRIBE SIGN UGHTING: t.-j , T-J L FEE: $20.C0, plus 91.00 per square foot of total sign area DRB fees are to be paid at the time of submittal PLEASE SUBMIT THIS APPUCATION, ALL SUBMITTAL REQUIREMENTS AND THE FEE TO THE DEPARTMENT OF COMMUNITY DWELOPMENT, lv\';IAL 75 SOUTH FRONTAGE ROAD, VArL COLORADO 815s7. To Whom It MaY Concern: I,theundersigrred,beingeitherabusinessownerand/orpropertyownelonEastMeadow Drive in vail do hereby request the Town of vail to rename East Meadow Drive (from Vail Road to Blue Cow Shoot) to Main Street' Print Name \r+;-ton East Meadow Diive JOINT PROPERTY OWNER WRITTEN APPROVAL TETTER I, (print nu^") &^S,U)<, 7u*e.V* ,a joint owner of property located at (address/legal descriprion) tnz' E ma.Jo;l Dr #rC: lai | 6^ I'G6? TOI{N provide this letter as written approval of the plans darcd y'/O- O) which have been submitted to the Town of Vail Community Development Department for the proposed improvements to be completed at the address noted above. I understand that the proposed improvements include: I further understand that minor modifications may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations. //-p -a> (Date) Page 2 of LZl02l07llz s4lLzl2BAZ 131 47 4762523 SLIFER I'IAI{AGEI'ENT CT] Slifer Management Company _Property Mauagement & Leasing_ PAGE A2 Af'jlt2,2cr/2 Dear Vail Villagc Plaza Board of Directors, Parl Zuegar ofthe Masters Gallcry wishes to alt€r the sigrage for his space. Any changes insignage mrw be approvcd by a majority of the Board ofDirectoi= "oA O" ioum of vail. rheproposed signage is as follows: - Replace the gr€en canvas on tbe awnings with a maroon/lrrugundy color and '.ldAsrERsGALLERY AT VAIL'white lstters stitched into the front (sce included photos). The signagcrnd avadngs rrould be chauged at both entrances to his space; so two s;g;would be prcseot ong" fi-,: fagade of the sdllery. The proposed sign4p would be vsy sirnilar to oe previous raseMoutain Sports signage, excryt "chaugo in thc cojoroftfre aumin!- - unfortunately, time b:f tu essc'rce in this approval process. Masters Gancry wisles to hav_e tlis i_tqn bmueht before rhe nfir Tou/n of viil meeting, ad ths dcadline for submission is5:00 p'm. Monday, April 15. Thus, I ask that you review thil letter and reium it at 1ow eadiestcwvenicnce. n Naur Signage NOT Approvcd BoardMcrnberSignanue: /r, /l*o-, h, ,{* fr-ru- -- Cordially, Jobn Birkeland hopertyManager Ft nero Sigxrage Approved Bosrd Menrber Name: PI,EASE?RINT I43 East Mcrdow Drive,360, vail, Cotorado 8tOf7 Tolqrhonc: (9'lO) 47 G l0 63 Fax: (9701a76-252t STAU:'ER i, /t2/2b82 16:5! 476252:5L IrfR MAI'IAGEMI l'li C0 Ffi iE oeL $,pnl 12.2001 Slifrr lvlanagement Com pany I'rope rty Managernent & Leasin,3_ Dear Vajl Viliage Plaza B.)rrd ol'l)irectors, Paul ZueS,ar of the Ma ,t :rs C allery wishes to alter the signage fo 'his space . Any chrrnges it signagcnrustbeapprovedblanLajorityoftheBoardofDirectorsanitheTownofVail.'lhe proponed sigl,age is as follc vs; Replace the green canr as on the awni.ngs with a maroon/burgund y color and 'MASI ERI fiALLERY 1,T VAII," wl i e let .ers stitched into the fiont (see rnclu led photos), The si.;r,age and awnrngs .vould bc chan 3ecl rt both enrances toh:s space; so twr signs would be pree{:nt c{ thefront fagale ofthe gallly, the proposed srgnage rvould be very sirnilar to thc previr'us llar e Mountain Sp' rrts signage, :t.cept r, change in the color of the awning Unfortun;rtely, ttme rs ) rtbe gr;sence in thrs approval process, M lstcrs Gallery rvieht,s to hnve this itenr bnrught bef rte tln next Town of Vail mee'ting, and th,: deadlinc for submissiorr i; 5:00 p.m. Mcnday, Aptil I 5. 'I'hus, I ask rhat you rr.r,ieu' this letter rnd retum it at your ,:arlies' convenigfce. llfNew liignage Approred n New Srgrage NOT Approved Datc: Board Menrber Name: PLEAI,E PRINT Board Menrber Signatrne: _ _ Cordially, John Birkelarrd Property Mar ager 14-1 [ast Me]dow Drivc, Surtr 160. Vail, Cololado 8155? 1 cie.pltorr : (9 70) 476- 1 063 lhx: (970) 41 6-2523 Slifer Management Company Property Management & Leasing December l7.2}0l Town of Vail Deparbnent of Community Development 75 South Frontage Road Vail, CO 81657 Re: Space 4125, Crossroads West To Whom It May Concern: Please be advised that the Landlord, Trevin4 L.P., and the Crossroads of Vail condominium Association have approved the proposed hanging sigr for the Gateway Gallery as described in the attached drawing and as showu in the attached digitally altered photograph. If you have any questions, dont hesitate to contacr me. Sincerelv. h*,r'%ifuf frf e- \.f '.f/' - a/ Steve Stafford Managing Broker, Slifer Management Company, Inc. Managing Agent for Trevina, L.P. President, Crossroads of Vail Condominium Association 143 East Meadow Drive, Suite 360, Vail, Colorado 81657 Telephone: (970) 4761063 Telefax: (970) 476-2523 A gallery for distinctive fiora*_Corey feltis TERS LLEIIY VailBoard, 1O0 East Meadow Drive, #27 phone. (g7)l 477_0600 E-maii : mastersgafl "rvu"itev"noj".lr,lg70l 47 7 -ooo1 We would like to witMrawthe sign variance with the understanding that allthe business on lvleadow Drive conqrly with the rules that have been put in plae. We will put up a sirlgle profrtc*ing sign and two window signs on the front ( Meadow Drive ). We will also put a sign on the west side of our localion. Thankyou for your help with ideas on our location. Sincerely, Paul Zueger...Orvner Sincerely, Corey Feltis... Director Vail, Colorado 81657 Phone (970) 477-0600 E-mai | : mastersgalleryvail@yahoo.com l0O East Meadow Drive, #27 Fax (970) 477-0601 /2882 14124 4762523 SLIFER MAI.IAGEMENT CO PAGE A2 Slifer Management Company Property Management & Leasing- April 12,2002 Dear Vail Viltage Plaza Board of Directors, Paul Zuegar of the Masters Gallery wishes to alter the signage for his space. Any changes in signage must be approvcd by a majority of the Board of Directors and the Town of Vail. The proposed sigtagc is as follows: Replace the gteen c;ulvas on the awnings with a maroon/burgundy color and "MASTERS GALLERY AT VAIL" white leners stilched into the front (see included photos). The signage and awnings would be changed at both entrances to his space; so nro sips would be present on the front fagade of the gallery. The proposed signage would be very similar 1o the Previous Base Mountain Sports sigtage, exccpt a change in the color of the awning. Unfortunately, time is of the esscncc in this approval process. Masters Gallery wishes to have ibjs item brought before the next Town of Vail meeting, and the deadline for submission is 5;00 p.m, Monday, April 15. Thus, I ask that you review this letter and retum it st your earliest convenience. 4U*, Signage Approved / tr New Signagc NOT Approved C/k-eLfZJ/4,f U . -/. Board MemberName: FLEASE PzuNT Board Mcmber Signature: Cordially, John Birkelard Property Manager 143 Easr Meadow Dtive, Suire 360, Vail, Colorado 81657 Telephone: (970) 4?6-t063 Fr;x: (970) a16-2523 BICDnpp 7 F a^-_ / i*/ tp7 ,,^./,. /tt sF*-/ ') ?7/_/ | ,-i - /'t,/,., t.: ..- \t:xr7|-)ff Prcject Namer Masters Gallery Sign PEC l{umber: PEC020018 Project Descrlption: Awnings Particlpants: OWNER Paul & Bonnie Flegler 04lL5l2OOZ Phone: 477-0600 100 E Meadow Dftlr.e #27 Vall, CO 81557 APPUCANT Paul& Bonnle Fiegler 0411512002 Phone: 477-0600 100 E Meadory Drtve #27. Vail, CO 81657 Project Address: 100 E MEADOW DR VAIL Location: Masters Gallery at Vail L.L.C. Legal Description: Lot! Block: Subdlvlsion: VAIL VILI-AGE PLqZA CONDO Parcel Number: 2101-082-5601-0 Comments: Motion By: Second By: Vote: @nditions: Planner: Bill Gibson BOARD/STAFF ACTIOil Acllon: WITHDRWN Dab ofApproval: PEC Fee Paid: $200.00 rr Application for Review by the ,fu Planning and Environmental Commission Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 fax: 970.479.2452 web: www.d.vail,co.us General Informationl All projects requiring Planning and Environmental Commission review must receMe approval prior to submiting a building permit application. Please refer to the submittal requirements for the particular approval that is requested. An application for Planning and Environmental Commission review cannot be accepted until all required information is received by the C-ommunity Development Department. The project may also need to be reviewed by the Town Council and/or the Design Review Board. Type of Application and Fe€i the Location of the Proposal: Lot:_Block:_ Subdivision: Physical Address: earce|No..@(ContactEag|e@.Assessorat970-328-8540forparce|no.) Zoning: Name(s) of Owner(s): #Owner(s) Signature(s): Name of Applicant: Address: E-mail Address: E Rezoning $1300tr Major Subdivision 91500tr Minor Subdivision $550E Exemption Plat $650tr Minor Amendment to an SDD $1000E New Special Development District 96000tr Major Amendment to an SDD $6000tr Major Amendment to an SDD 91250 (no exterior m odifr ca ti on s) tr Conditional Use Permitn FloodplainModificationtr Minor Exterior Alterationn Major Exterior AlterationO Development Plan El Amendment to a Development Plantr Zoning Code AmendmentE Variance p Sign Variance $6s0 $400 $6s0 $800 $1500 $2s0 $1300 $500 $200 iM Maili49 Address: \@ Fax hto nl4o" Page l of5-01i l8/02 For Office UFn pnly: Fee Paid: 6AAU . No.: JOINT PROPERTY OWNER WRITTEN APPROVAL LETTER I, (print name description) provide this letter as written approval of the plans dated which have been submitted to the Town of vail community Development Department for the proposed improvements to be completed at the address noted above. I understand that the proposed improvements include: I further understand that minor modifications may be made to the plans over the course of the review process to ensure compliance with the Town's applicable codes and regulations. 4-ut> (Date) G--.".-.*""--.. --'' ,/'\__=,,/ Pase2 of 5-01/18102 TOfi'Nffi Application for a Sign Variance Submittal Requirements GENERAL INFORMATION Sign variances may be granted in order to prevent or to lessen such practical difficulties and unnecessary physical hardships inconsistent with the development objectives of the Town of Vail. A practical difficulty or unnecessary physical hardship may result from the size, shape, or dimensions of a structure, or the location of the structure, from topographic or physical conditions on the site or in the immediate vicinity, or from other physical limitations, street locations, or traffic conditions in the immediate vicinity. Cost or inconvenience to the applicant of strict compliance with the sign regulations shall not be a reason for granting a variance. I. SUBMITTAL REOUIREMENTS o Fee: $200.00 n Stamped, addressed envelopes and a list of the property ownens adjacent to the subject property, including properties behind and across streets. The list of property owners shall include the owners' name(s), corresponding mailing address, and the physical address and legal description of the property owned by each. The applicant is responsible for correct names and mailing addresses. This information is available from the Eagle County Assessor's office. o Written approval from a condominium association, landlord, and joint owner, if applicable. D A written description of the nature of the variance requested and the specific regulation(s) involved, including an explanation of why the variance is required and why the strict or literal interpretation of the specific regulation(s) would result in a physical hardship or practical difficulty n Existing and Proposed Site and Grading Plans (Four complete sets of plans). tr Existing and Proposed Architectural Elevations (Four complete sets of plans). o Colored scaled drawings (3 copies). Indicate the proposed lettering including dimensions u Detaaled drawing showing how and where the sign or awning will attach to the building (3 copies) o Description and sample of proposed materials o All plans must also be submitted in 8.5" x 11" reduced format. These are required for the Planning and Environmental Commission members' information packeG, a Additional Material: The Administrator and/or PEC may require the submission of additional plans, drawings, specifications, samples and other materials if deemed necessary to properly evaluate the proposal. II. DETAILEDSUBMITTALREOUIREMENTS Site and Grading Plan:u Scale of I"=20'or largertr Property and setback linesa Existing and proposed easementsa Existing and proposed grades Paee 3 of5-0li l8/02 D Existing and proposed layout of buildings and other structures including decks, patios, fences and walls. Indicate the foundation with a dashed line and the roof edge with a solid line.o All proposed roof ridge lines with proposed ridge elevations. Indicate existing and proposed grades shown underneath all roof lines. This will be used to calculate building height.tr Proposed driveways, including percent slope and spot elevations at the property line, garage slab and as necessary along the centerline ofthe driveway to accurately reflect grade.o A 4' wide unheated concrete pan at the edge of asphalt for driveways that exit the street in an uphill direction.o Locations of all utilities including existing sources and proposed service lines from sources to the structures.a Proposed surface drainage on and off-site.o Location of landscaped areas,o Location of limits of disturbance fencingo Location of all required parking spaceso Snow storage areas.o Proposed dumpster location and detail of dumpster enclosure,o Retaining walls with proposed elevations at top and bottom of walls. A detailed cross-section and elevation drawings shall be provided on the plan or separate sheet. Stamped engineering drawings are required for walls between 4' and 6'feet in height.o Delineate areas to be phased and appropriate timing, if applicable Architectural Elevations :o Scale of 1/8" = 1' or larger; 1/4" is preferred o All elevations of the proposed development drawn to scale and fully dimensioned, The elevation drawings must show both existing and finished grades. Floor plans and building elevations must be drawn at the same scale.e If building faces are proposed at angles not represented well on the normal building elevations, show these faces also.D Elevations shall show proposed finished elevation of floors and roofs on all levels.o All exterior materials and colors shall be specified on the elevations.o The following shall be shown graphically and fully dimensioned: fascia, trim, railings, chimney caps, meter locations, and window details.E Show all proposed exterior lighting fixtures on the building.o Illustrate all decks, porches and balconies.tr Indicate the roof and building drainage system (i,e, gutters and downspouts).o Indicate all rooftop mechanical systems and all other roof structures, if applicable.o Illustrate proposed building height elevation on roof lines and ridges. These elevations should coordinate with the finished floor elevations and the datum used for the survey.tr Exterior color and material samples shall be submitted to staff and presented at the Design Review Board meeting. PRE.APPLICATION CONFERENCE A pre-application conference with a planning shaff member is strongly encouraged. No application will be accepted unless it is complete. It is the applicant's responsibility to make an appointment with the staff to determine submittal requirements. TIME REOUIREMENTS The Planning and Environmental Commission meets on the 2nd and 4th Mondays of each month. A complete application form and all accompanying material (as described above) must be accepted by the Community Development Department by the appropriate submittal date, which is a minimum of four (4) weeks prior to the date of the PEC public hearing. Pase 4 of 5-0lll8/02 Approval of a variance shall lapse and become void if the project for which the sign was granted is not diligently pursued toward completion within two (2) years from when the approval becomes final. Please note that only complete applicuions will be accepted. All'of the required information must be submiaed in orderfor the applicaion to be deemed completa Paee 5 of5-0i/I8/02 7" 3 an,,urszrk*g ath;T ]aruDaMrntpM tksSc' ry: ftmrutA 2D Vktr- llb YhtL, oD. 8)r,s? TERS LLERV loo EastMeadow Dtive,#21 Vail, Colorado 81 557 #6a vL^I 6 fl /b57 rl L '4nt#l TEAS LLERY 100 East Meadow Drive, #27 Vail, Colorado 81652 Trfz S rWru /a,ufu urru r,,/,&SoC tmp,l I,r z E. Me-rDazu DB \lnt, M 8lbs7 _, " TH|S ITEM MAYAFFECT YOUR pROpERTy PUBLIC NOTICE NOTICE lS HEREBY GIVEN that the Planning and Environmental Commission of the Town of Vail will hold a public hearing in accordance with Section 12-3-6 of the Municipal Code of the Town of Vail on May 13,2002, at 2:00 P.M. in the Town of Vail Municipal Building. In consideration of: A request for a major amendment to Special Development District No. 6, Vail Village Inn, to allow for the continued conversion of accommodation units into employee housing units and a request for a conditional use permit, to allow for Type lll employee housing units located at the VailVillage Inn, 100 East Meadow Drive/Lots M,N and O, Block 5D, VailVillage 'l't Filing. Applicant: Daymer CorporationPlanner: Russ Forrest A request for a variance from Section 114B'128 (a) Vail Town Code, to allow for a second - 1 Business projecting sign, located at 100 East Meadow Drive/Lot O, Block 5D, Vail Village 1stffrrrno. ! A^-ri^^^+. Master GalleryPlanner: Bill Gibson A request for a variance from Section 1148,-128 (4) Vail Town Code, to allow for a banner, located at 141 East Meadow Drive/Lot P, Block 5D, Vail Village 1" Filing. Applicant: The Baggage ChequePlanner: George Ruther A request for a conditional use permit and an amendment to a development plan in the General Use Zone District, to allow for an addition to the Town of Vail Public Works Shops, located at 1289 Elkhorn Drive/Unplatted. Applicant: Town of Vail, represented by Victor Mark Donaldson ArchitectsPlanner: Allison Ochs A request to rezone the Lodge at Lionshead includingTracts | & J, Block 1, Vail Lionshead 1st Filing from Agriculture Open Space (AOS) to Lionshead Mixed Use -1 (LMU-1) and a request to rezone 380 E. Lionshead Circle/Lot 7, Block '1 , Vail Lionshead 1st Filing and 360 East Lionshead Circle/Lot 6, Block 1, Vail Lionshead 2nd Filing from High Density Multiple Family (HDMF) and Medium Density Multiple Family (MDMF) to Lionshead Mixed Use -1 (LMU-1). Applicant: Lodge at Lionshead, represented by Jeff Bailey.Planner: Russ Forrest A request for a minor subdivision of Lot 2, Block 1, Vail Lionshead Second Filing (Evergreen Lodge) and Lot F, Vail Village Second Filing (Medical Center); a request to rezone a portion of Lot 2, Block 1, Vail Lionshead Second Filing (Evergreen Lodge) from Special Development Dishict No. 14 to Lionshead Mixed Use 1; a request to rezone a portion of Lot 2, Block 1, Vail Lionshead Second Filing (Evergreen Lodge) from Special Development District No. 14 to General Use; a request to rezone a portion of Lot F, Vail Village Second Filing (Medical Center) from General Use to Lionshead Mixed Use 1; and a request to amend the study area defined in the Lrbnshead Redevelopment Master Plan and setting forth details in regards thereto, located at 250 S. Frontage Rd. West lLol2, Block 1, Vail Lionshead 2no Filing and 18'l South uv I Frontage Road West / Lots E and F, Vail Village Second Filing. MwNOFyAIL Applicant: Evergreen Hotel and the Vail Valley Medical Center , rPlanner: Allison Ochs A request for a joint worksession with the Design Review Board and Planning and Environmental Commission, to discuss a conditional use permit to allow for a private educational institution and a request for development plan review to construct employee housing within the Housing Zone District and setting forth details in regards thereto, located at the site known as'Mountain Bell"/an unplatted piece of property, located at 160 N. Frontage Rd./to be platted as Lot 1, Middle Creek subdivision. Applicant Vail Local Housing Authority, represented by Odell ArchitectsPlanner: Allison Ochs A request for a recommendation to the Vail Town Council, of a text amendment to Title 12, Section 2-2, to amend the definition of "Fraction Fee Club" and to amend Title 1 2, Section 16- 7A-8, to amend the Use Specific Criteria & Standard, and setting forth details in regard thereto. Applicant: Rob Levine '''Planner: George Ruther The applications and information about the proposals are available for public inspection during regular office hours in the project planner's office, located at the Town of Vail Community Development Department, 75 South Frontage Road. The public is invited to attend project orientation and the site visits that precede the public hearing in the Town of Vail Community Development Department. Please call 479-2138 for information. Sign language interpretation available upon request with 24-hour notification. Please call 479- 2356, Telephone for the Hearing lmpaired, for information. Community Development Department Published April 26, 2002in the Vail Daily. TO: FROM: DATE: SUBJECT: MEMORANDUM Planning and Environmental Commission Department of Community Development May 13,2002 A request for a variance from Section 11-48'-128 (4) Vail Town Code, to allow for a second business projecting sign, located at 100 East Meadow Drive/Lot O, Block 5D, VailVillage 1s'Filing. Applicant: Masters GalleryPlanner: Bill Gibson il. DESCRIPTION OF THE REQUEST The Masters Gallery is requesting a variance to allow for a second business projecting sign (i.e. awning) at 100 East Meadow Drive (VailVillage lnn site). Section 11-48.-128 (4) of the Town of Vail Sign Regulations states the following: Number: One sign per vehicular street of major pedestianway which the busrness abufs, as determined by the Administrator with a maximum of two (2) signs, subjecf to design review. This application involves the placementol a 12.2 square foot awning sign above the southwest side door entry. This sign would supplement the illegally existing 18.5 square foot projecting sign above the south front doors along East Meadow Drive. Both signs are pending review by the Design Review Board and must comply with all applicable provisions of the Town's Sign Regulations. The applicant's statement of the nature of the variance request is attached for reference. REVIEWING BOARD ROLES The PEC is responsible for evaluatinq a proposal for: 1. The relationship of the requested variance to other existing or potential uses and structures in the vicinity. 2. The degree to which relief from the strict or literal interpretation and enforcement of a specified regulation is necessary to achieve compatibility and uniformity of treatment among sites in the vicinity, or to attain the objectives of this Title without grant of special privilege. 3. The effect of the requested variance on light and air, distribution of population, transportation and traffic facilities, public facilities and utilities, and public safety. 4. Such other factors and criteria as the Commission deems applicable to the proposed variance. Desiqn Review Board: Action: The DRB has NO review authority on a variance, but must review any accompanying DRB application. The DRB is responsible for evaluating the DRB proposal for: - Architectural compatibility with other structures, the land and surroundings - Fitting buildings into landscape - Configuration of building and grading of a site which respects the topography - RemovaUPreservation of trees and native vegetation - Adequate provision for snow storage on-site - Acceptability of building materials and colors - Acceptability of roof elements, eaves, overhangs, and other building forms - Provision of landscape and drainage - Provision of fencing, walls, and accessory structures - Circulation and access to a site including parking, and site distances - Location and design of satellite dishes - Provision of outdoor lighting III. STAFF RECOMMENDATION Upon review of the criteria outlined in Section lV of this memorandum, the Community Development Department staff recommends denial of the variance request to allow for a second projecting sign, 100 East Meadow Drive/Lot O, Block 5D, Vail Village 1"'Filing, based upon the following finding(s): 1. That special circumstances or conditions do not apply to the land, building, topography, vegetation, sign structures or other matters on adjacent lots orwithin the right-of-way, which would substantially restrict the effectiveness of the sign. 2. The variance applied for departs from the provisions of the Vail Town Code more than is required to identify the applicant's business use. tv. A. CRITERIA FOR EVALUATION - SIGN VARIANCE Consideration of factors: 1. Special Circumstances Exist There are special circumstances or conditions applying to the land, buildings, topography, vegetation, sign structures or other matters on adjacent lots or within the adjacent right-of- way, which would substantially restrict the effectiveness of the sign in question, provided, however, that such special circumstances or conditions are unique to the particular business or enterprise to which the applicant desires to draw attention, and do not apply generally to all businesses or enterprises. The applicant states this variance is necessary to facilitate business identification to pedestrians along East Meadow Drive for three reasons: 1. Large groupings of trees block the middle front of the location. 2. The major entrance is over 25 feet from the street. 3. They are a total of three retail spaces (#10, 15, and27). This situation is similar to other properties along East Meadow Drive. Additionally, there are alternatives under the provisions of the Town's Sign Regulations that could meet the applicant's objectives without the need for a variance. Staff does not believe there are special, unique circumstances on this site that warrant a deviation in the application of the Town's Sign Regulations. 2. Applicant Not Responsible: That such special circumstances were not created by the applicant or anyone in privy to the applicant Staff does not believe there are special, unique circumstances on this site that warrant a deviation in the application of the Town's Sign Regulations. 3. Harmonv Maintained: That granting of the variance will be in general harmony with the purpose of the sign code, and will not be materially detrimental to the persons residing or working in the vicinity, to adjacent property, to the neighborhood, or to the public welfare in general. Staff does not believe an approval of this variance request would be materially detrimental to the persons residing orworking in the vicinig, to adjacent property, to the neighborhood, or to the public welfare in general. 4. In Line With Provisions: The variance applied for does not depart from the provisions of this Title any more than is required to identify the applicant's business or use. The Town of Vail Sign Regulations allow for use of window signage that could address many, if not all, of the applicant's concerns. Therefore, staff believes there are alternatives under the provisions of the Town's Sign Regulations that could meet the applicant's objectives without the need for a variance. 5. Other Factors: Such other factors and criteria as the Planning and Environmental Gommission deems applicable to the proposed variance. B. The Planninq and Environmental Gommission shall make the followinq findings before granting a variance: 1. That special circumstances or conditions apply to the land, building, topography, vegetation, sign structures or other mafters on adjacent lots or within the right-of-way, which would substantially restrict the effectiveness of the sign. 2. That such special circumstances were not created by the applicant. 3. That granting the variance will be in general harmony with the purpose of this title and will not be detrimental to the public health, safety or welfare, or materially injurious to properties or improvements in the vicinity. 4. The variance applied for does not depart from the provisions of the Vail Town Code more than is required to identiff the applicant's business use. 7-^* / .r*'12 t"', y4*J / /*-* wf7 / [,* Zl*fr ,/'4 "rz/a!.W H/4 1'tt "il%;a. oH'ro,*n A a?lqz H//' /'-' Y"t/ u,"-Ik*\ + 4-e1 U rru,^+ /*4 b.& lt s* v;0 I 'i!''ff | I w*,, ry4b46+a73. /iln..* "4*!,p /v/,"^ FR-Ii :FI1X NO. :Ilr.r9. 24 ZBAF A9:..l?Fi"l Pt /&*af6,*,)*/W* t .az*>tt--UP ?fl/4***- 3 4o"4..*A a"rL fr,/*.- h ,i{GtDa I t1t. | .' .r 3 Stints gi&t ---'la"-'---l*l ffi J/ ssrp itlf gd It;,4'- e.?/ii.*6rk,t 1A &sef,l.J?ortr sft 'fu t TOhATOFVAIL 75 S.FRONTAGEROAD VAIL, CO 81557 970-479-2738 Job Address: Location.......: Parcel No....: Project No . : Occupancy: Type Construction: Type Occupancy: Valuation: Fireplace Information: Building---> Plan Check--> Investigation-> will call-> .,-.\ \.,,f\,,.,, !_l DEVELOPMENT "'it-, \_i -",1 U, \\.-.r_..,p7,.. r, ,,) DEPARTMENT OF NOTE: THIS PERMIT MUST BE POSTED ON IOBSITE AT ALL TIMES o COMMI-INITY M V 1-HR Type V 1-Hour 1) $11,500.00 Restricted: $155 . oo Restuarart Plan Review-> $107.2s DRB Fee'-.---> $165.00 RecreationFee-------> 93.00 Clean-upDeposit-----> TOTAL FEES----------> Add SqFt: # of Gas Appliance's: 0 Permit #: 801-0353 Status. . . : Applied. . : Issued . ..: Expires . . .: Phone: ISSIJ'ED 11./1.4/2001 12/M/2007 06/02/2002 # of Gas Logs: 0 #of Wood Pelleh *E** FEE SUMM $o - oo Total Calculated Fees-> go. oo Ad4itional Fees--> So - o0 Total Pero{t Fee--> $0.00 PaYmmts-_----_-2 $440.2s BALANCEDUE---> 9440.2s s0. 0o $440 - 25 544 0 - 25 $o. 0o Approvals:I€e.m: 05100 BUIL,DING DEPARTMENT Lr/23/2ooL cdavis Action: COND ALI-, CORRECTIONS ON FIEIJD PLANS MUST BE ADDRESSED Item: 05400 PITANIIING DEPARTMENT Item: O5600 FIRE DEPARTI{ENI Iten: 05500 PUBLIC WORKS ADD/ALT COMM BUILD PERMT 1OO E MEADOW DR VAIL 210108256030 f vZSDi -ou5q uNlr#3o f[aftqrf Wl"q OWNER A.iI . PROPERTY TRUST C/O DREYER EDMONDS & ASSOC 355 S GRAND AVE STE 4]"50 L,OS AItrcELES CA 90071-3103 1-t/ 14 / 2001-Phone: License; COMIRACTOR High Country Enterprises 24,1.L/L4 / 20O]- P. O. Box 383 472 MaLIr Street Minturn, CO 8164 5 License:685-B APPIJICANI High Country Enterprises 74,LI/1-4/200L Phone: 97O-A27-41,40 P.O. Box 383 472 ltlain Street Minturn, CO 81545 . Li-cense: Desciption: TENANT FINISH ADD NEW ALIS AND SEAL TILE REPAINT ECT ********i****r************i************* See page 2 of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required completed an accurate plot plan, and state that all the infonnation as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved Uniform Building Code and other ordinances of the Town applicable thereto. REQIJESIS FOR INSPECTION SUALL BE MADE TWENry-FOUR HQURS IN ADVANCE BY TELEPHONE AT 479-2138 OR AT OUR OFFICE FROM 8:00 AM - 5 PM, Send Clean-up Deposit Tor N/A NTRACTOR FOR HIIV{SELF AND OWNEI PAGE2 ***{iffi*!H*******!t******r**********r&***r**dl1t!**l************.}*{r**lit**f*t ffi*****ti***{i******** CONDMONS OF APPROVAL Permit#: 801-0363 asof 12-04-2001, Starus: ISSUED ********ffi********iu***r*d*********lit****tt*rtlrt****rt*****titii*t!*****tt********rt**********tf*******r.**i| PermitType: ADD/ALTCOMMBLIILDPERMT Applied: 11/1,4/2N1, Applicanf High Country Enterprises 74,lnc. Issued: 72/04/2001, 970-82741.40 ToExpire 06/02/20[.2 job Address: 100 E MEADOW DR VAIL Location: tlNIT # 30 ParcelNo: 210108255030 Description: TENANT FINISH ADD NEW ALTS AND SEAL TILE REPAINT ECT Conditions: Cond:1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond:12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. -l i ll IF INCOMPLETE OR U NVT{OFUAE 75 S. Frontage Rd. Vail, Colorado 81657 echanical. etc.! Building Per-mit #: General Crntractor: . 11 q ah C,etttl n Qnt.-l*St Town of Vail Reg. No.;b{>s-6 lgntact and Phone.#'s: Ep^+l.l-O)trn6onztlaa{| -axLadz Contractor Signature: JtYh^.,Mu \, Ithplere vllVlrrorus FoR BUTLDTNG pERMrr (Labor & Materials - \-/ BUILDING: $ b.MD. -ELECTRICAL: $ 2.W.^OTHER: PLUMBING: $A.ttDD.-MECHANICAL: $ -f rnr,rt . t lf €1^-a - For Parel # Contact EaEle County Asressorc Office RourED to: L'4ntlt'n tt$ti*ei,*&g ofivitfi tA,rl,. ea q n DIIF DUE: ,oo*u'"fio+a.S &rUeW i2flifls% Jdl rl i[o.' o/o>* Legal Description ll Lot:Block: /Filing:Subdivision: t I olnff,YT":S, ,-t/,9A Mf'ttl t ncda- nn.#Kgtror- ?)K oqiH{o?"P,'1fl*k G.#4$f inn*1" tnivr*rrrn G M Engine€r: I Address:Phbne: Detailed description of work:4;;J i=;A-, iJ.Q n',0', u'tuoJ) c;ftQ" asnd^-t a.l *.-il;U"---Adclition( ) Remodet rK *"wrlio.rot 4 other( ) Work Type: Interior (/) Exterior ( ) Both ( )Does an EHU exg!-at this location: Yes ( ) No t4 Typeof Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercl3l g{ Restaurant( ) Other( ) No. of Existing Dwelling Units in this buildingl No. of Accommodation Units in this building: No/TvoeofFireolacesExistinq: GasAopliances( )Gastms( )Wood/Pellet( )WoodBurninq( ) ,rd,JC-- No/Tvpe of Fireplaces Proposed: Cas nd2lilffres ( ) Gas Loss ( ) Wood/Pellet ( ) Wood Burning (NOT ALLoWED) Does a Fire Alarm Exist: Yes (n No ( )Does a Fire Sprinkler System Exist: Yes ( , ) No (-T **************************************FOR OFFICE USE ONLY***************************tr********** : :, r- ;i.off:'':',: F :/everyone/formVbldgperm '|l .,.tt. '1_ | "rri A. l. -Jtr'., I r t ti tY:;'Yt tif niAru .cfl;' lrt-'1[5.r. fi*fift- .ifi.?,(.' I'. lli:: ., '>vili: , r)'t,.:;-il;?;: ' I i., t-'' ':" r'' -'i j'*,\,T-,il{il il i ;q'lli, rll-fi "] l- f ., - i t ;- r . jtri.i .. . . ,1;J *)t ltty.: . l"F.o- -- l* t ,'>e'"! l\!r1. ,-, ,. .r(Si-l ''' t- . nF.i..'.e'l*J l{tJ ' - .cii:.r;r..,. , ;A* ir: t:.. ;:^ei'i-rr'ii : ,. t?*, rxar.rrr . rllr: a Questions? Callthe Building Team at 479-232s I0l{'N Department of Comm unity Development / This Ch*klirt must be nmpleted before a Buildino Permit aooliation is ,rceoted. 6 )ll paSes of application is complete 6rms DRB approval obtained (if reduired) Provide a copy of approval form d fcondomiilum Association letter of approval attached if project is a Multi-Family complex d Complete site plan submitted {TuVtirWay Permit application included if applicable (refer to Public Works checklist) ef Staging plan i4cluded (refer to Public Works checklist) No duinoster,oarkino or material storaqe zSflowed on roadwavs and shoulders without written aooroval QXsbestos test and results submitted if demolition is occurringd /rchitecl stamp and signature (All Commercial and Multi family)6 ltchitecl stamp and signature (All Commercial and Multi family) d fA floor plans including building sections and elevations(4 sets of plans for Multi-Family and Commercial) ils Report must be submitted prior to footing inspection ire resistive assemblies specified and penetrations indicated moke detectors shown on olans Types and quantity of fireplaces shown Applicant's Signature: Date of submattal: il -q'OI F:/everyone/forms/bldperm2 Received By: o ,,-_-\ -Ir{I'Js./,/ Mm0Fvuill HOW DIDWE RATE WITH YOU? Town of Vail Survey Community Development Departnent Russell Forres! Director, 1. Which Depa@ent(s) did you contac0 Buifding ,/ Enuironmental_ Housing_ Admin or 7. n Planning . DRB _ PEC _ 2. Was yourinitialcontactwith ourstaffimme aiAe /stow no one available ? lf you were required to wait, how long was it before you were helped? 4.Was your project reviewed on a limely basis? Yes / No lf no, why not? Was this your first time to file a DRB app_ PEC app Bldg Permit N/A Please rate the performance of tre sbifiperson who assisted you:54321Name: (knowledge, responsiveness, availability) Overall efiectiveness of he Front Service Counter. 5 4 3 z What is the best time of day for you to use fte Front Service Counter? 9. Any comments you have which would allow us to beter serve you nexttme? Thank you for taking the time to complete this survey, We are committed b improving our service. It I o BUILDING PERMIT ISSUANCE TIME FRAME If this permit requires a Town of Vail Fire Department Approval, Engineer's (Public Works) review and approval, a Planning Depaftment review or Health Department review, and a review by the Building Department, the estimated time for a total review will take as long as three (3) weeks. All commercial (large or small) and all multi-family permits will have to follow the above mentioned maximum requirements. Residential and small projects should take a lesser amount of time. However, if residential or smaller projects impact the various above mentioned depaftments with regard to necessary review, these projects may also take three (3) weeks to review and approve. Every attempt will be made by this department to expedite this permit as soon as possible. I, the undersigned, understand the plan check procedure and time frame. I also understand that if the permit is not picked up by the expiration date, that I must still pay the plan check fee dnd that if I fail to do so it may affect future permits that I apply for. Agreed to by: Project Name: Print name F:everyone/forms/bldperm3 APPLICATION FOR TOWN OF VAIL PUBLIC WAY PERMIT 19 Pw*:I[-rIln Parcer#:r: I n I - I I n - [ ! - I f ! Brds.Permiio'E I n,f I I f { Job Nam€Streot Address n Tl [l - l-_l (lr unknown carl| | | | | | I | 479-AlgBel:t.0) Excavating Contractor Name Meillng Address TOV Contractor's Licen6e Number REOUIRED () Z9City Phone # 4. Starl Date Work is for (circle one) Other Completion Dale Waler Sewer Gas Electric (Pormii Expiraiion Dat€) Telephone CATV Landscaping Temp. Site Access 5.Trench-width (min,4') Bond Amount $ ALL MATERIAL. EQUIPMENI AND TRAFFIC JOB IS STARTED. L Rubber out-riggers are required on Asphalt surfaces underneath the A signature below indicates a signatures are obtained, permittee necessary Town of Vail signatures. BE ON THE JOBSITE BEFORE THE working on asphalt. at all times. uiility locations and approvals. Once all utility company application through the Public Works office to obtain the up to one week to process. Depth Total SF $ Toral LF $ Permit Fee Total Permit Fee $ Public Service Company (1-800-922 Public Service Natural Gas Group (1-800-922-1987) U.S. West (1-800-922-1987) TCI Cablevision of the Rockies (1-800-922-1987) Eagle River Water & Sanitation District (970-476-7480, ext. 114) Holy Cross Electric Company (1-e00-922-1987) Town of Vail Electricians (970-479-2158) Town ol Vail lnigation (970479-2158) Town of Vail Public Works Construction Inspector (970-479-21981 ' r' 9. THEBE WILL BE NO TOTAL STREET CLOSURES! A construction lraffic control plan must be approved by the Public Works Department prior to issuance ol the permit. _.-f.j .^,,.-,.'l r..l ) i ':' 1 0. AII excavation must be done by hand within 18" of utilities - (Senate Bill 172), 11. Permitte€ must contact Public Wo*s Department at 479-2198 24 hgursflrior to commencing of work. Failure lo notify the Town will result in forfeiture of bond money' scheduled inspcilionsrvhich ere n*oJ tgFdy rnay result in the Town chargirig the contractor a reinspection lee. . . 12. I certity that I have read all chapters ol Title I - Public Ways and Property, ol the Vail Municidal Codti and all utility company agreements, signed by me, and wlll abide by the same, and that all utilities have been notified as required. ATTACH PLAN OF WORK, INCLUDING CONSTRUCTION TRAFFIC CONTROL PLAN Show streets'with names, buildings, and location of cuts. USE DASH LINES FOR CUT. White - Public Worke Yellow - Contractor o DRAINAGE AND CULVERT INSPECTIONS ARE REOUIRED BY PUBLIC WORKS! Please read and check offeach of the items below: o The Town of Vail Building Depaftment has developed the following procedures to ensure that new construction sites have adequately established proper drainage from building sites along and adjacent to Town of Vail roads or streets. o The Town of Vail Public Works Depaftment will be required to inspect and approve drainage adjacent to Town of Vail roads or streets and the installation of temporary or permanent culvefts at access points from the road or street onto the construction site. Such approval must be obtained prior to any requests for inspection by the Town of Vail Building Department for footings, temporary electrical or any other inspection. Please call Leonard Sandoval at 479-2198 to request an inspection from the Public Works Depaftment. Ailow a minimum of 24 hour notice. o Also, the Town of Vail Public Works Department will be approving all final drainage and culvert installation with resulting road patching as necessary. Such approval must be obtained prior to any Final Ceftificate of Occuoancv issuance. Agreed to by: Print Name Signature i'.r;-!3r'. 1''^5 !. .' r9" 1( Project Name: Date Signed:gt.,.i..;..!.. F:/everyone/forms/bldperm6 Please read and check off each of the items below. (Copies of complete text are available upon request) CODE 5-2.10: DEPOSITS ON PUBLIC WAYS PROHIBITED q Unlawful deposits: Subject to subsection C thereof, it is unlawful for any person to litter, track or deposit, or cause to be littered, tracked or deposited, sand, gravel, rocks, mud, dirt, snow, ice, or any other debris or material upon any street, sidewalk, alley or public place, or any portion thereof. o Notice; Abatement: The Director of Public Works may notiff and require any person who violates or causes another to violate the provision of subsection A hereof, or who has in the Director's employment a person who violates or caus$ another to violate the same, top remove such sand, gravel, rocks, mud, dift, snow, ice or any other debris or material within twenty four (24) hours after receipt of said notice by the Director of Public Works. In the event the person so notified does not comply with the notice within the period of time herein specified, the Director of Public Works, or other authorized agent, may cause any such sand, gravel, rocks, mud, dirt, snow, ice, debris or any other material to be removed from any street or alley at the expense of the notified. o Summons and Penalty: As an alternative to the notice for removal provided in subsection B above, any person who violates or causes another to violate the same, may be issued a summons to appear before the Municipal Court of the Town for said violations, and upon being found guilty of a violation hereunder be punished as provided in Section 14-1 of this code. o Notice and Penalty: It is unlawful for any person to fail or refuse to comply with the notice of the Director of Public Works as provided in subsection B hereof, and any such person shall, in addition to payment of the expense of removal incurred by the Director of Public Works, as provided in subsection B hereof, upon being found guilty of a violation hereunder, be punishable as provided in Section 1-4-1 of this Code. (1997 Code: Ordinance 6 (1979). CODEST-3A-1 AND 7.3A-3: PARKING OBSTRUCTINGTRAFFIC&IMPOUNDMENTAUTHORIZED o No person shall park any vehicle upon a street or at any other place within this Municipality in such a manner or under such conditions as to intefere with the free movement of vehicular traffic or proper street or highway maintenance. (Ord. 2(1968) g 1) u Whenever any police officer finds a vehicle attended or unattended, standing upon any poltion of a street or upon any place within this Municipality in such a manner as to constitute a violation of any section of this Article, or left unattended for a period of twenty four (24) hours or more and presumed to be abandoned under the conditions prescribed by Colorado Revised Statutes section 42-4-1102, as amended, the officer shall require the vehicle to be removed or cause it to be removed and placed in storage in the nearest garage or other place of safety designated or maintained by this Municipality, and the charges for towing and storage of such vehicle shall be charged to the owner of the vehicle in addition to a ten dollar ($10) impoundment charge, (Ord. 2(i968) 5 3: Ord. 28(1981) 5 1) I have read and will comply with the above code provisions: -S;\Qtl+Zqkg Position or Relationship to Project: Date Signed: l(-Q'e ( Ir :/cveryone/lbrms/bldpermT . Print Name TO\^INOF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2138 I DEPARTMENT OF COMMUNITY D o EVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON TOBSITE AT ALL TIMES ELECTRICALPERMT Permit #: E07-0275 Job Address: 100 E MEADOW DR VAIL Status . . . : ISSUED Location.....: UNIT # 30 Applied. . : 12/03/2007 Parcel No...: 210108256030 Issued . . : 12/04/2007 ProjectNo:?f:"1pt er{g} Expires..: 06/02/2002 owNER A.,J. pROpERTy TRUST L2/O3/2OOL phone; c/o DREYER EDMOIIDS & ASSOC 355 S GRAND AVE STS 4150 LOS ANGELES CA 90071-3103 Li.cense: COMIRACTOR A.K. EIJECTRIC L2/O3/ZOOL phone: 970-390-3258 2]-03 ZEMATT I,ANE IINIT 2103-A VAIIJ, CO 8L657 IJicense: 1L7-E APPITICANT A-K. EIJECTRIC L2/O3/2O0L phone:970-390-3258 2]-03 ZEMATT I,ANE I]NIT 2]-03-A VAIL, CO 81557 License : l- 17 -E Desciption: ELECTRICAL FOR NEW GALLERY Valuation: $5,000.00 FEE SUMMARY El€chical---> S90.00 Total Calculated Fees-> S93.00 DRB Fee-----> lnvestiga tion--> will call--._-> TOTAL FEES_> $0.00 s0.00 $3-00 $e3 .00 Additional Fees--->$0.00 Total perllrit Fee__> 993.00 Payments---------> S93 .00 BALANCE DUE.--_->90.00 Approvals:I€elm: 05000 ETECTR]CAL DEPARTMENIT t2/O3/2OOl. JP:M Action: AP Item: 05600 FfRE DEPARTMENT CONDITIONSOF APPROVALCond: 12 (BLDG.): FIEI-,D INSPECTIONS ARE REQUIRBD TO CHECK FOR CODE COMPLIANCE' DECLARATIONS I hereby acknowledge that I have read this applicatiorL filled out in full the information required, completed an accurate plot ptan, and state that all the information as required is correct. I agree to comply with the inforrnation and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review 'ftrereto. Uniforur Building Code and ordinarrces of theTown applicable t approved, BEQU.ESIBFORSiSFECTON SHALL BE MADE TWENTY.TOURHOIJRS IN ADVANpM.. ] other OUROmrgrnOMs:fi)AM-5 I - O(sAPPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGDED Electricil Permit #: 970-479-2149 (Inspections)' ; TDWT{OFVAN 75 S. Frontage Rd. Vail. Colorado 81657 CONTRACTOR INFORMATI Of-0Y 'V'{E/or/",c-Town ofVail Reg. No.:6//7 Contad and Phone #'stTan. 3l.o -?L58 '*.''re'{'Tq-Q FE 1, sQ ET FOR NEW BUILDS and VALUATIONS FOR ALL OTHERS (Labor & Materiats) AMOUNT OF sQ FT IN STRUCTURE: / S O ELECTRICALVALUATION: $ 4; ConEct ::eunty Assessors Offict at 920-328-864O or v, fia't{-tfl a'" '<" ' " w.eaele-countv.com for ParceI # Parcel# (Required if no bldg. perm@ Job Name:robAddress: / 0a Ei rileolroi /r Legal Description ll Lou ll Btock: ll riting:Subdivision: Owners Name:Address:Phone: Engineer:Address:Phone:ff,r - Detailed description of work: btea:kn I c-,\{o -- Work Class New() Addition( )Remodel )d Repair ( )--lTempPower( ) Other( ) Work Type: Interiorl)4 Exterior ( ) Both ( )Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family ( ) Duplex ( ) MuttFfamily ( ) Commerciatb<( Restaurant( ) Other ( ) No. of Existing Dwelling Units in this building:No. of Accommodation Units in this buildinq: Is this permit for a hot tub: Yes ( ) No ( ) Does a Fire Alarm Exist: Yes ( ) No ( )Does a Fire Sprinkler System Exist: Yes ( ) No ( ) ***** * ** * ) \n\ /l t\ t1 Y> oNLY******************************************************************FOR OFFICE USE \ Other Fees:Date Reccived: -1 DRB Fees:AcceDted By: Planner Siqn-off: \ Ir F :/everyone/forms/elecperm lit: '1 ;:{ ri HIGH COUNTRY ENTERPRISES, 7 4 INCORPORATED TO: Town of Vail Building Department RE: Ilandicap ramp for IVlasten Gallery 100 E. Meadow Dr. Permit number80l-0363 Dear Sir As per our conversalion concerning the handicap ramp it was shted thd if the total cost of installing a handicap ramp exceeds Zff/o of the permitted cost of construction tlnt a ramp would not need to be installed. The valuation of the building permit is $11,500.00. The plumbing was delegated lowering the cost by another $4,500.00. The cost for a new ramp is $7,019.00 and another $600.00 fior railing for a total of $7,619.00. This far exceeds the2tr/o.I have included a copy ofthe proposal from The Gallegos Corpordion that details the cost for the ramp. Please contact me if you need anymore information regarding this matter. My cell phone number is 904{007. Sincerely Jim Gonmles Jan. 9. 2002 PO.Box383 . Minturn,CO 91645 . Tel/Fax970.827.4140. www.hce74.com . email:hcn74@home.com CONTRACTORS FOR: Stone Mosonry Morble Gronite Stucco Ploster Concrete Flotwork Decorolive Concrete Wofer Feolures Fireoloces MEMBER: Building Stone Institute Morble Institute of AmericoR!kffi DETIVER VAII ASPEN January 9,2002 Exhibit A Job #50-5394 PR#1050.0 Page 1 of3 High Country Eri.erprises P.O. Box 383 Mintum, CO 81645 Attention: Jim Gonzales Regarding: Dear Jim: Concrete work at Masters Gallery,350 Meadow Drive, Vail The Gallegos Corporation proposes to furnish all labor, materials, equipment and supervision necessary to complete the following concrete work per our conversation on January 9,2002; ar:.d as qualified in this proposal. This proposal is to be attached to the contract and recognized as contract document Exhibit A. A. Work at the Entry Ramp lncludes: 1. Demolition and removal of entry walk and steps 2. Fine grade 3. Rebar mat #4 at 16" O.C. each way 4. #1 tebar dowels at 16" O.C. lo buildins 5. 4000 psi gray concrete 6. Forming and forming matenals 7. Place and finish concrete 8. Control joints 9. Curing compound Price of A ..'...'-.....-....---$7'019.00 DENVER 4155 E. Jewell Ave., Suite 1000 Denver, Colorado 80222 303.753.1021 phone 303.753.1357 fax VAIL CORPORATE HEADQUARTERS Post Office Box 821 Vail, Colorado 81658 970.926.3737 phone 970.926.3727 lax SOO.Gallegos www.GallegosCorp,com ASPEN Post Office Box 488 Aspen, Colorado 81612 970.927.4200 phone 970.927 .1L22 tax Juuary 9, 2002 Exhibir A Job /50.5394 PR #1050.0 Page 2 ol3 Specific Exclusions: 1. 2. J. A 5. 6. 7. 8. 9. 10. 'i1Il 1aI z. Permits, tests, inspections, certification of any kind Winter protection, ice and snow removal of any kind Overtime Concrete pump - (Price reflects pouring from chute) Embeds Flashing, caulking and sealing of any kind Waterproof membranes of any kind Location and/or relocation of irrigation and utility systems Landscaping ofany kind Sub-slab insulation or vapor barriers ofany kind Bid, Periomrance, Labor & Matcrial Bond Fces Installation of handrails Cracking Frost heave Settling Spalling Efflorescence Discoloration of colored concrete The General Contractor is responsible for the following items: Access for compressor, dump trucks, form trucks, concrete trucks and pump All survey, layout and elevations Protection of completed work Traffic control ofany kind Templates or blockouts of any kind Builders risk insurance and deductible Compaction of subgradc to + l" to bottom of slab if muck excavation is necessary Fill material for fine grade Temporary lighting as required The Gallegos Corporation will not be responsible for concrete damage due to the following cc:rCiticns which are bevond o'.rr cnntrol, 1l. 2. 3. 5. 6. Please contact us ifyou have any questions regarding this paragraph or the proposal. The price quoted in this proposal will remain in effect for 10 days. If a contract is not submitted within that time, you must contact us to determine whether the proposal can remain in effect for any longer period of time, and, if not, what changes will have to be made to either adjust the scope ofwork or increase the contract price. This proposal is specifically conditioned upon the &N lmuary9,2@2 Exhibit A Job #505394 PR #1050.0 rage J or J project proceeding according to the schedule which we have been provided, and upon the project being ready for our part of the work as scheduled at the time of the proposal. If there are any delays in the progress of the work, beyond the control of The Gallegos Corporation, which result in our being unable to either commencc or complete our w,ork, it may be necessary for us to adjust the amount of any contract which results from this proposal by the amount of increase in our actual costs of labor and materials. but in no event less than the increase in the construction price index in Colorado. Terms: Net 30 days with progress billing by the 25th of each month and payments due by tlre 25th of the following month; thereafter 2ot6 interest per month on anpaid due balance. All payments should he mailed to The Gallegos Corporatiort's muin office address: P,0, Box 821, Vuil, Colorsdo 8165E. Pleuse do not drop off or mail payrnents to the Basalt or Denver ofJices. In the event of any litigation arising out of this contract, the prevailing party shall have a right to recover from the other party all costs and expenses of such litigation including attorneys fees. If you agree to the scope of work and terms and conditions outlined above, please indicate by signing below and returning one copy to our office. Signer must be authorized to sign for owner. This will act as a contract should no other contract be issued. If a contract is to be issued, this signed proposal will be an authorization to proceed. Thank you for the opportunity to submit this proposal. Sincerely, FOR: Mike Cleveland, President Concrete Division I agree to the above terms & conditions. HIGH COUNTRY ENTERPRJSES GOS CORPORATION MC/SC/rbw BY DATE oo ?t'/t 0-'l,t