HomeMy WebLinkAboutVail Village Filing 2 Lot E & F VVMC (26) ---- '-------- '- - - _ _ -- - .....--- --- ADJ . ADJUSTABLE INSUL. i INSULATION APPLICABLE BUILDING CODES: NOTE: CONTRACTOR TO COORDINATE STAGING, STORAGE, PARKING, CONSTRUCTION ACCESS AND RELATED ISSUES -- - -- -----`- - - -- --- --- - - - WITH THE OWNER PR�OR TO COMMENCING WORK. A.F.F. ; ABOVE FINISH FLOOR KBT. ! KEY BOARD TRAY 2003 INTERNATIONAL BUILDING CODE --- - --- - .... -- --------------- - AL. ALUMINUM MECH. ' MECHANICAL � 2003 INTERNATIONAL PLUMBING CODE -- - -�- - ---- ----- ?--- 1 . ERECT AND MAINTAIN DUST- PROOF PARTITIONS AND CLOSURES AS REQUIRED AND OUTLINED BY THE HOSPITAL __ B•0. i _BY OWNER MIN _ __ _ __MINIMUM_ � 2003 INTERNATIONAL MECHANICAL CODE 125 DOOR IDENTIFIER DETAIL IDENTIFIER TO PREYENT SPREAD OF DUST, NOISE AND FUMES TO OCCUPIED PORTIONS OF THE BU�LDING AND TO PROVIDE CFf. � CERAMIC FLOOR TILE MTL. ; METAL ` � ��^� 2002 NATIONAL ELECTRICAL CODE FREE AND SAFE PASSAGE OF PERSONNEL AND GENERAL PUBLIC TO AND FROM OCCUPIED PORTIONS OF THE CONC. i CONCRETE N0. NUMBER �� 2003 INTERNATIONAL FIRE CODE ----- - - - BUILOING . _ ---- ; ni . � CONT. _ ; CONTINUOUS O.C. ON CENTER __ __ OFFICE 2002 NFPA 72 NATIONAL FIRE ALARM CODE 2. GENERAL CONTRACTOR TO PROVIDE PROTECTION FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION CORR. ; CORRIDOR P. ; PAINT NEW ROOM IDENTIFIER AMERICANS WITH DISABILITIES ACT GUIDELINES � - - - - - --- - -- 000 WORK TO FLOOR AND FINISHED SURFACES TO REMAIN . CONTRACTOR SHALL MINIMIZE INTERFERENCE OF C .M . U. CONCREfE MASONRY UNIT P. LAM. PLASTIC LAMINATE LIFE SAFEfY CODE-2003 NFPA 101 � � � Archit lS CONSIRUCTION WITH ONGOING BUSINESS. CONTRACTOR TO CONTACT OWNER A MINIMUM OF SEVEN DAYS PRIOR CPT. f CARPEf RB. RUBBER BASE LJFE SAFEfY SYS7EMS: AUTOMATIC SPRINKLER SYSTEM AND DEfECTORS � TO COMMENCING DEMOLITION TO SCHEDULE WORK . CWT. ; CERAMIC WALL TILE RE: ' REFER � DETAIL SECTION IDENTIFIER THROUGHOUT THE BUILDING. - - - -- - -- -'- -- INTERIOR ELEVATION REFERENCE 3. CONTRACTOR SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND DEBRIS. REMOVE DBL. DOUBLE REF , REFRIGERATOR �„ � ai . i OCCUPANCY 7YPE AND CONSTRUCTION: _.. - -- - -- --- PROTECTIONS AT COMPLEfION OF WORK. PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT FACILITIES BY DISP DISPENSER _ RM _ ROOM OCCUPANCY: B - - -- - DEMOLITION AND/OR CONSTRUCTION WORK AT NO COST TO THE HOSPITAL. DW. I DISHWASHER _ RO ROUGH OPENING _ __ CONSTRUCTION 11'PE: 1 -A EA. � EACH S. F. ': SQUARE FEEf EXISTING FIRST FLOOR BGSF: 53,869 S. F. - - -- _ - --- - - -- T SIM . SIMILAR REMODEL AREA : 1 432 S. F. 4. DO NOT SCALE DRAWINGS. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MFAN THAT THE CONDI ION IS ELEC. ELECTRIC - - - BY OWNER ' ���• N� - THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS, UNLESS OTHERWISE NOTED. DETAILS ARE USUALLY ELEV. ; ELEVATION S.S. � STAINLESS STEEL PRWECT DESCRIPTION: KEYED AND NOTED "TYPICAL" ONLY ONCE WHEN THEY FIRST OCCUR AND ARE REPRESENTATIVE OF ALL SIMILAR EQ. EQUAL STD. STANDARD O WINDOW IDENTIFIER RENOVATION OF AREAS WITHIN THE FIRST FLOOR OF THE HOSPITAL. EGRESS AND ��� F���� CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED. EQUIP. EQUIPMENT STDS . STANDARDS INFECTIOUS CONTROL TO BE MAINTAINED AT ALL TIMES. EXT. EXTERIOR STRUCT. STRUCTURE -- Q?Z6 MAN BTR�T . UI�NT C101 5. THE CONTRACTOR SHALL MAINTAIN THE EXISTING STRUCTUR,4L AND FIREPROOFING INTEGRITY THROUGHOUT THE _-__- __...___- -__- -___ _ TYPICAL SYMBOL DESIGNATIONS. mWARDB, COLORADOM632 ENTIRE PROJECT AREA. PROVIDE ELECTROLYSIS PROTECTION BEfWEEN ALL DISSIMILAR METALS, WHERE THEY EXIST. ; EXISTING _ SUSP. ! SUSPENDED _ MAY NOT BE USED IN THE DRAWINGS. 970.�.MOOF.Y70.926.MQ1 OCCUR. (E) EXISTING -m'�T- -�T�AL AREA CHANGED TO B OCCUPANCY AS NO PATIENT CARE WILL BE PROVIDED IN THIS AREA -- - - --- -- DIMENSION LINE OF THE BUILDING. NUCLEAR MEDICINE IS AN OUT- PATIENT IMAGING SERVICE. THE FD. FLOOR DRAIN TREAT. ! TREATMENT 4'-5�' STERILE PROCESSING COLLECTION RECEIVES SOILED INSTRUMENTS, CLEANS AND 6. THE OWNER SHALL BE CONTACTED IN REGARDS TO ANY SALVAGEABLE MATERIAL OR EQUIPMENT. ANY -------- ----- -- - - SALVAGEABLE ITEMS NOT TO BE REUSED OR WANTED BY OWNER SHALL BECOME PROPERTY OF THE CONTRACTOR. GA. ' GAUGE U .C_L. __:UNDER CABINEf LIGHT REPACKAGES INSTRUMENTS FOR PROCEDURES DELIVERED THROUGHOUT THE BUILDING VIA GALV. � GALVANIZED U . N.O. UNLESS NOTED OTHERWISE CARTS. THE CART WASH WILL BE USED TO CLEAN CARTS PRIOR TO RESUPPLYING THEM --- ---t- - - ---- -- - - --- - ' WITH STERILE INSTRUMENTS. 7. CONTRACTOR SHALL PROVIDE ADEOUATE BLOCKING IN WALLS TO RECEIVE ALL ATTACHED EQUIPMENT, GL. ; GLASS V. I. F. VERIFY IN FIELD � V��� PLUMBING FIXTURES, MILLWORK , CASEWORK, EfC . NOTE: ALL FRAMING OR CONCEALED BLOCKING SHALL BE 20 GYP. BD. ': GYPSUM BOARD VCT. VINYL COMPOSITION TILE T0� ���� GAUGE SHEET MEfAL. G. C. � GENERAL CONTRACTOR W ' WITH �� 1NALL TYPE TAG O�F'C� 8. PROVIDE SEALANT AROUND ALL PLUMBING FIXTURES WHERE THEY ABUT ADJACENT SURFACE. HGT. �, HEIGHT WB. ; WOOD BASE H. M . ' HOLLOW MEfAL WD. WOOD 9 . CONTRACTOR SHALL PATCH AND REPAIR WALLS, FLOOR AND CEILING AS REQUIRED FOLLOWING DEMOLITION OF � EXISTING PARTITIONS AND EXISTING FINISHES. p /1pBREVIATIONS 'NPICAL ABBREVIATIONS. MAY NOT BE USED IN THE DRAWINGS. p 0 S i MBOLS p, p BUILDING CODE INFORMATION 10. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED, BUT REQUIRED FOR THE PROPER EXECUTION OR INSTALLATION , OR PERFORMANCE OF THE WORK , SHALL BE PROVIDED BY THE CONTRACTOR. THE CONTRACTOR SHALL PERFORM HIGH QUALITY, PROFESSIONAL WORK . MATERIALS SHALL BE JOINED IN A MANNER 1 . ALL FINISN SAMPLES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO TO PROVIDE A UNIFORM , ACCURATE FIT; WITH NEAT STRAIGHT LINES, FREE OF SMEARS OR OVERLAPS. INSTALL VERIFY AVAILABILITY AND STOCK OF MATERIALS AND ALLOW ENOUGH TIME TO RECEIVED GOODS FOR INSTALLATION �ER VAIL VALLEY MEDICAL CENTER EXPOSED MATERIALS APPROPRIATELY LEVEL, PLUMB, AND AT ACCURATE ANGLES, OR FLUSH WITH ADJOINING TO OCCUR AT REQUIRED TIMES. 181 WEST MEADOW DRIVE MATERIALS. 2. CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS, FLOORS AND CEILINGS AS REQUIRED FOLLOWING VAIL, COLORADO 81657 � DEMOLITION OF EXISTING PARTITIONS AND EXISTING FINISHES. PATCHED AREAS SHALL BE UNDETECTABLE. �_ CONTACT: DARRYL FLORES (970) 479 -7119 11 . WHERE PLUMBING FIXTURES, PIPING, MEDICAL GASES, ELECTRICAL FIXTURES, MECHANICAL EQUIPMENT, OR ANY 3. WHERE NEW PARTITIONS ADJOIN EXISTING BUILDING PARTITIONS, THE NEW PARTITION FINISH SHALL ALIGN WITH ( � �� }, �, i � Z; f �;,; �j\ i, ) X, `�\ � RYAN MAGI�L (970) 904-0066 _ _ _ OTHER EQUIPMENT IS REMOVED, ALL PIPING AND/OR CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF EXISTING FINISH. � � / �, '� � • � � � : � % / ' ' -- - - -- - -- - BELOW THE FLOOR INSIDE WALLS OR ABOVE CEILINGS AS APPROPRIATE. FINISHED SURFACES OF NEW WORK MEEfING EXISTING CONSTRUCTION OF SIMILAR MATERIALS IN THE SAME PLANE ' - X �� % t �� l� �� � � f� /� �� \� f� - n ARCHfiECT DAVIS PARTNERSHIP, P.C. CATORRUNAiA880CY►7BB, C0. SHALL BE FLUSH WITH NO VISIBLE JOINT SHOWING. WHENEVER EXISTING FINISH MATERIAL AND/ OR SURFACES 0225 MAIN ST. , UNIT C101 16QODONBtB'TRff�. 8URE2 12. CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLEiELY FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR MUST BE CUT OR OPENED, THIS IS TO BE REPAIRED AND RESTORED SO THAT THE FINISHED PATCH IS TYPICAL WALL TYPE "� EDWARDS, COLORADO 81632 LAI�WOOD, COl�76 TO SUBMITTING PRICES AND STARTING WORK. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY UNDEfECTABLE AND MATCHES A�JOINING AND ORIGINAL WORK IN EVERY WAY. 3 �" METAL STUDS AT 16" O.C. WITH 1 LAYER �" GYPSUM BOARD, BOTH SIDES CONTACT: SCOTT NEVIN, AIA (970) 926-8960 CONDITIONS OR DISCREPANCIES ADVERSELY AFFECTING THE DESIGN INSTALLATION PRIOR TO PROCEEDING WITH THE 4. WHERE CONSTRUCTION HAS DISRUPTED THE EXISTING WALLS, FLOORS, CEILINGS, ETC . THE FOLLOWING SHALL EXTEND WALLS 6" ABOVE FINISHED CEILING U. N.O. CHERYL DORNAK , AIA (970) 926-8960 WORK (INCLUDING CONFLICTS WITH MECHANICAL DUCTS, STRUCTURE, PIPING, CONDUIT RUNS, MECHANICAL UNITS, OCCUR: ISBUFJREVISION DATE NO. LIGHT FIXTURES, CEILING FEATURES OF FLOOR BELOW, FIRE SPRINKLERS LINES OR HEADS, ETC . ) WHETHER A. WHERE WALLS HAVE BEEN REPAIRED AND PATCHED, THE ENTIRE WALL IS TO BE REPAINTED, SO THAT THE MECHANICAL � ELECTRICAL CATOR, RUMA 6 ASS�CIATES, C0. EXISTING OR NEW. PATCH IS UNDETECTABLE ACROSS THE ENTIRE WALL SURFACE. ENGINEER 1550 DOVER STREET SUITE 2 TOV CODE REVIEW 1JUNE07 B.WHERE WALL BASE HAS BEEN REPAIRED AND PATCHED, NEW BASE TO MATCH EXISTING SHALL INFILL 2' - 6" IN LAKEWOOD, COLORADO 80215-3132 13. GENERAL CONTRACTOR TO CLEAN ANY EXISTING WINDOW TREATMENTS, FLOOR FINISHES, AND CASEWORK THAT EITHER DIRECTION OF THE PATCH RND REPAIR (5'-0" LINEAR FEEf TOTAL) TO MAKE THE PATCH UNDEfECTABLE. ASI # 1 13JUN07 ARE TO REMAIN . C . WHERE FLOOR HAS BEEN REPAIRED AND PATCHED, NEW CARPEf, VCT, VINYL SEAMLESS FLOORING AND/OR CONTACT: ELECTRICAL - KAY BATHKE (303) 232- 6200 TILE TO MATCH EXISTING SHALL INFILL 3'- 0" IN ANY DIRECTION OF THE PATCH AND REPAIR (9 ' - 0" SQUARE FEET MECHANICAL - MICHAEL JOHNSON (303) 232 - 6200 14. CONTR.4CTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BEfWEEN ARCHITECTURAL AND ENGINEERING - -------- - - - - --- - - -'- -- DRAWINGS, SPECIFICATIONS, OR EXISTING CONDITIONS. TOTAL) TO MAKE THE PATCH UNDETECTABLE. CONTRACTOR TO BE DETERMINED D.WHERE CEI�ING HAS BEEN REPAIRED AND PATCHED, NEW CEILING GRID , ACOUSTICAL CEILING TILE, AND/OR APPROVED 15. CONTRACTOR TO CHECK BUILDING OWNERS STOCK FOR THE REUSE OF CONSTRUCTION ITEMS INCLUDING; GYPSUM BOARD TO MATCH EXISTING SHALL INFILL 2' -0" IN ANY DIRECTION OF THE PATCH AND REPAIR (4'-0" p�q DOORS / HARDWARE / SINKS, ETC. DURING BID PHASE. IF ITEMS ARE TO BE REUSED, SUBMIT LIST AND SQUARE FEEf TOTAL) TO MAKE THE PATCH UNDETECTABLE. IF CEILING GRID AND/ OR TILES ARE TO BE �� Y ' � ���p rs� �nd �I�� CONDITION TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION/INSTALLATION . REPLACED, THEY SHALL BE REPLACED IN WHOLE INCREMENTS, SO AS TO MAKE THE PATCH UNDETECTABLE. WHERE GYPSUM BOARD CEILINGS ARE PATCHED AND REPAIRED, THE ENTIRE CEILING IS TO BE REPAINTED, SO 16. CONTRACTOR TO SCHEDULE A CHALK WALK WITH THE ARCHffECT AND OWNER. CONTRACTOR TO INFORM THAT THE PATCH IS UNDEfECTABLE ACROSS THE ENTIRE CEILING PLANE. ��j"�y�W��r������ ARCHITECT AND OWNER OF ANY DEVIATIONS FROM PROPOSED ROOM SIZE OR CEILING HEIGHT FOR APPROVAL BY 5. ALL VERTICAL DIMENSIONS SHOWN TO FLOOR ARE TO BE FINISHED FLOOR, UNLESS NOTED OTHERWISE. notbtopNlnMAlop� � p� br, Qan �ppay�p�, ��r� OWNER. CONTRACTOR TO SCHEDULE AN ELECTRICAL BOX WALK WITH THE ARCHITECT OWNER. CONTRACTOR TO �NHERE FINISH IS TO BE CARPET, VERTICAL DIMENSION IS TO SLAB. +rryaril� dw+ md� ardanyafreidnMiw�!! 6. WHERE EXISTING WORK IS TO REMAIN AND BE REPAINTED, PATCH AND REPAIR AS REQUIRED, SO THAT ALL �� ���,�,� ��b���� SCHEDULE A FINAL PUNCH WALK WITH THE ARCHITECT AND OWNER. IF MORE THEN ONE PUNCH LIST WALK THRU pATCHED AREAS ARE UNDETECTABLE. NEW WORK THAT ADJOINS EXISTING SURFACES SHALL BE FLUSH , TRUE, P�� Of� �" "' ""'"' IS REQUIRED, CONTRACTOR IS TO COMPENSATE FOR ARCHITECT'S AND ENGINEER'S EXPENSES. ��dTM �ur� da beeeamcoruYUr�fo� ��r�I�1y PLUMB AND/OR IN SAME PLANE AS THE EXISTING WORK AND FINISHED TO BLEND AND MATCH IN TEXTURE AND dhxdM� arl �of eonectiono(erron co FINISH WITH ADJACENT SURFACES. FLOAT PATCHES AND JOINTS A MINIMUM OF 24" WIDE TO BLEND. � 17 . THE PRESENCE OF THE ARCHITECT OR REPRESENTATIVE ON THE JOB SITE DOES NOT IMPLY CONCURRENCE DuiYwqcpkallt � � OR APPROVAL OF THE WORK. THE CONTRACTOR SHALL CALL SPECIFIC ITEMS IN WRITING TO THE ATTENTION OF 7 . CONTRACTOR SHALL TAKE CARE TO PROTECT ALL NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS �„� ,�n � THE ARCHITECT TO OBTAIN THE ARCHITECT' S APPROVAL. NO CHANGES TO THE CONTRACT CAN BE MADE WITHOUT FORMALLY ACCEPTED BY THE ARCHITECT AND OWNER. DAMAGED ITEMS OR FINISHES ARE TO BE REPAIRED OR �yrYtirlioa REPLACED, AS REQUIRED BY THE ARCHITECT. - T`"=--� THE OWNER'S CONTACT, AS LISTED ABOVE, WRITTEN APPROVAL , 0, 8. ALL FLOOR TRANSITIONS TO OCCUR AT THE CENTERLINE OF THE DOOR UNLESS OTHERWISE NOTED. FLOOR TRANSITION STRIPS SHALL BE SUBMITTED TO ARCHITECT FOR COLOR SELECTION . FLOOR TRANSITIONS REQUIRED p p PARTICIPANTS �' o �'�� 18. THE CONTRACT DOCUMENTS ARE THE RESPONSIBII_ITY OF ALL TRADES IN THEIR ENTIRElY. WHERE AT ALL CHANGES IN FLOOR MATERIALS. � � REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE SPECIFICATIONS �R DRAWINGS BUT NOT ANOTHER, THE g , A L L M E f A L A C C E S S D O O R S, E L E C T R I C A L P A N E L S, F I R E E X T I N G U I S H E R C A B I N E T S, E T C. , T O B E P A I N T E D T O ' CONTRACTOR OR SUBCONTRACTOR IS NOT RELIEVED FROM PROVIDING COMPLETELY FINISHED AND PROPERLY �1+,' L I � : � FUNCTIONING SYSTEMS. MATCH ADJACENT WALL OR CEIILING COLOR. , � . 10. EXTEND EXISTING FINISH AS REQUIRED WHERE DEMOLITION HAS REMOVED FINISH. INFILL FLUSH AND MATCH SHEET � SHEE7 NAME REV. � DATE 19. ALL WORK UNDER THIS CONTRACT TO BE IN STRICT ACCORDANCE WITH REGULATIONS FOR CONTRACTORS EXISTING UNLE55 NOTED OTHERWISE. ; �' I - ; . - PERFORMING WORK AT THE HOSPITAL AS FOLLOWS: 11 . HINGES TO BE HEAVY DUlY, BALL BEARING, 4- 1 /2"x4- 1 /2 ", 3 PER LEAF FOR DOORS 7' -0" HIGH AND i � ` � / A. PROVIDE OWNER WITH LIST OF ALL SUBCONTR,4CTORS, CONTACTS AND TELEPHONE NUMBERS. LESS. HINGES TO BE STAINLESS STEEL, WITH FLAT BUTTON TIPS. �H��� � „ , �: / 12 . ALL HARDWARE TO BE LEVER TYPE TO MEETS ADA GUIDELINES. A0.0 GENERAL INFORMATION �-, , ` B. CONSTRUCTION HOURS ARE 7 :00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY UNLESS OTHERWISE APPROVED � � � �� BY THE OWNER, WITH AT LEAST 48 HOURS ADVANCE NOTICE. 13 . DOOR FINISHES TO BE RED OAK . DOORS TO BE FLUSH DESIGN , 1 - 3/4" THICK , SEAMLESS FACE AND EDGE A0.1 SPECIFICATIONS _ - �� C . CONTRACTOR IS RESPONSIBLE FOR BAGGING ALL SMOKE DEfECTORS AND IS RESPONSIBLE FOR ANY COSTS CONSTRUCTION. AR11 ' LIFE SAFETY PLAN- OCCUPANCY & SEPARATI�NS i - INCURRED FROM DAMAGE TO ALARMS DUE TO DUST OR ANY OTHER CONSTRUCTION ACTIVIIY. 14. ALL WOOD DOORS & WELDED FRAMES WITHIN THE WORK AREA TO BE PAINTED. AR1,2 LIFE SAFETY PLAN- EGRESS D. ANY WORK ON THE FIRE PROTECTION SYSTEM OR FIRE ALARM SYSTEM MUST BE COORDINATED THROUGH THE 15 . HOLLOW MEfAL FRAMES TO MEEf SDI (STEEL DOOR INSTITUTE) REQUIREMENTS, INCLUDING SDI - 105-91 AND AI.O ' DEM�LITION, FL�OR , REFLECTED CEILING PLANS ' OWNER AND LOCAL FIRE DEPARTMENT. SDI- 100-91 . A2.0 SCHEDULES, DETAILS , AND INTERIDR ELEVATI�NS E. CONTRACTOR SHALL NOT SHUT OFF OR PUT OUT OF SERVICE ANY SYSTEM/SERVICES WITHOUT FIRST 16 . REFER TO FLOOR PLAN FOR LOCATION OF FIRE EXTINGUISHER CABINET. PROVIDE FULLY RECESSED, - - - COORDINATING WITH THE OWNER AT LEAST 72 HOURS IN ADVANCE. ENAMELED STEEL CABINEf WITH SOLID DOOR WITH RED, VERTICAL, VINYL LETTERS. OWNER TO PROVIDE FIRE EXTINUISHER. UL-R.4TED 2 -A: 10- B: C, 5- LB. MECHANICAL � 20. DIMENSI�NS OF AND FROM EXISTING CONDITIONS HAVE BEEN TAKEN FROM EXISTING DRAWINGS AND/OR FIELD MI,Ol ' MECHANICAL LEGEN AND SCHEDULES MEASUREMENTS. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PERTAINING TO EXISTING CONDITIONS M1.02 SPECIFICATI�NS � PRIOR TO THE START OF CONSTRUCTION. M3.01 PARTIAL FIRST FLOOR HVAC PLANS 21 . DIMENSIONS LOCATING NEW CONSTRUCTION ARE TO FINISHED FACE UNLESS NOTED OTHERWISE. DIMENSIONS M4.01 PARTIAL FIRST FLOOR PIPING PLANS � LOCATING EXISTING CONSTRUCTION ARE FROM EXTERIOR FINISHED SURFACE UNLESS NOTED OTHERWISE. M5.00 : PARTIAL FIRST FLD�R PLUMBING PLANS - SANITARY WASTE �� M5.01 PARTIAL FIRST FLDOR PLUMBING PLANS 22. NOTIFY ARCHITECT OF ANY DISCREPANCIES UNCOVERED BY DEMOLITION; OR IF EXISTING CONDITIONS PREVENT M6.01 PARTIAL SECOND FLO�R ENLARGED MECH PLANS LAYOUT FROM PROVIDING PROPER CLEARANCES. M6,02 ' PARTIAL SECOND FLOOR ENLARGED MECH PIPING P�ANS ��� 23. DOOR ASSEMBLIES IN INTERIOR PARTITIONS ARE 6" FROM FINISHED FACE OF ADJACENT PARTITION TO THE M7.01 ': GAS PIPING DIAGRAM � EDGE OF THE DOOR LEAF UNLESS NOTED OTHERWISE. NOTE. 1 . PROVIDE SOUND ATTENUATION BATTS IN ALL NEW WALLS (TYPICAL) . pE��� � 24. CONTRACTOR TO REPAIR ANY DAMAGE FROM REMOVING EXISTING FINISHES OR WALLS TO INSURE THAT E1,01 ELECTRICAL LEGENDS, SCHEDULES AND SPECS Med�cal a_iRrorF ic cr�nnru n,n�n PRFPPFfI FnR cniNTin�r_, aNn Wni i �pvFRiNr_.. PRnviDF THF MINIMni FI IRRING E3.04 ELECTRICAL 1 -LINE DIAGRAM NORMAL POSSIBLE IF EXISTING WALLS OR DAMAGED WALLS CANNOT BE PROPERLY PREPARED TO RECEIVE NEW FINISH . E3.05 ELECTRICAL 1 -LINE DIAGRAM EMERGENCY Center 25. CONTRACTOR TO ACCESS EXISTING CONDITIONS AND RESTORE ALL RATED PARTITIONS AND ASSEMBLIES AS E4.01 PARTIAL FIRST FLDOR LIGHTING AND POWER 8� SYSTEMS PLAN REQUIRED. E6.01 ELECTRICAL DETAILS AND PANEL SCHEDULES o.o GENERAL NOTES o.o INTERIOR FINISH NOTES o. WALL TYPES o.o DRAWING INDEX � � ( C� .� _ _. ._ .. _ .. . . . . ...... . . . . . . ... . ... . . INDICATES EXISTING WALLS OR INDICATES EXSITING WALL � PARTITIONS TO REMAIN D1 EXISTING CASEWORK TO BE REMOVED INDICATES NEW 2 'x4' CEILING GRID WITH NEW ?° -° �� :�:� ;- ACOUSTICAL CEILING TILE/ACT 1 � wesr vni� � r TOIREMAINEXISTING DOORS D2 EXISTING SHELVING AND FRAMING INSEf TO BE REMOVED INDICATES NEW WALL SITE LOCATION . _�_ ���n _ ., First Floor INDICATES NEW DOOR �' /� /. � � INDICATES EXISTING WALLS OR D3 EXISTING SOFFIT TO BE REMOVED NORTH NUM�1 M�I�� PARTITIONS TO BE REMOVED CONTRACTOR TO COORDINATE REMOVE OF FLOOR FINISH ___ .,_ ' ' ' �' � SPC Remodel - INDICATES EXSITING DOOR • I ' ` "� '�� �^" ' INDICATES GYPSUM BOARD CEILWG OR SOFFIT Mnin� vnn txn € �� � � INDICATES EXISTING DOORS AND D4 WITH NEW CONSTRUCTION BEfWEEN TWO POINTS. BASE TO ''• :� ' :� ' ;• :1 nnnc u� c�l.� r -- -� �L crf����rc� RF RFMOVF^ AND WAI I S oaroo�p �pa oA!PlT. '�: . -1 vvv : •. . ,Z',: �. nr,K= . . . . _ .. . .. � INDICATES NEW 2 'x4' RECESSED � D5 EXISTING FLOORING, BASE, CEILING TO BE REMOVED. �O FLUORESCENT FIXTURE �'vTE'RSTqT � INDICATES EXSITING GYPSUM BOARD CEILING so�rH E y� a / p . INDICATES NEW 2 'x2' RECESSED ' OR SOFFIT ` ,, wESr FRONr"�E ROqp cH�9r y UsT vA��� -y �c ��� A bi q O � �,+ �� �r �: � '� � � vii ... ` ' : � � ✓, 1 . WHEREVER PLUMBING FIXTURES, PIPING, ELECTRICAL FIXTURES & MECHANICAL EQUIPMENT IS REMOVED, ALL � FLUORESCENT FIXTURE � COR�' W R�� n % , n�; � s � r ,. � ,i� 1 S W. M e ,._. ciRC�e ' �.: : e •- .: r,,,,,,,,,,,.: . . . ... . ... . •...,.a ; ;. .� y� � .,H _..... ____.._. .. .__._.._._ ` 1 eadow Driv , � ...:. . _._. ._...___....: ..: PIPING AND/OR CONDUITS THAT ARE ABANDONED SNALL BE CAPPED OFF BELOW THE FLOOR, UNLESS NOTED � �� , �.�° " v ` `� '��`;/�'!��`!�;';; w, �". ::�:�,;;.<.;�. >. . � : • r,�,,,, c...i� '^^`..< � � . .:::::::�i;i oP K : � �. ; ... .;., :�... . . .. ��.j...; . .__., Vail Colorado OTHERWISE. ELECTRICAL AND MECHANICAL ITEMS TO BE REMOVED ARE DEFINED ON THE E & M SERIES OF E .; � MEADOW �sr ""` ` �•^ �° ; >u � " ' f :. Q INDICATES INCANDESCENT DOWNLIGHT CgE = `, Ers� DRIV M�Dp i=-°°�, � � � y `� � '' � ��`•sya `+��% ' `9 `" �'s� ; � ,. �;n,,;.� , - :.., �` , _,a„i: - � � � �" ; DRAWINGS. CONTRACTOR TO COORDINATE PROPOSED RELOCATED ITEMS WITH OWNER AND ARCHITECT PRIOR TO � � - _= \\ E �,� W �R��E ` � + ^• .- --,. £ � � ^� "°"� � $� ' M "y '"� � � � `' � � � 81657 INSTALLATION. o wi��ow � , __,, , ° ' ; _ .,n..,. 3:;:q, ..,,�;,. .,,. .�.�a .; x,,.,,;..,.�., 6 ;w �,..,,, . . �;:: �� � ; 2. CONTRACTOR TO CAREFULLY REVIEW AND ASSESS THE VARIOUS SLAB CONDITIONS AND COORDINATE FLOOR �--�� INDICATES UNDER CABINET LIGHT m B�� p Rp,y� p , BRIDGE CORE y � �°�' ' {j, '���py� (�";i!"� "�:"°°� "` °f "'�" g "°" � y' ' `' ` " .:• \ C �z� / �. � : ` ..k rL...,.;'�.......�M �__.__ ___..s w ua � s y�5{< ' 'j ' y . ,,,.i - --�-..._.___::-'s_�:z::.--- ""-'... �2 / , PATCHWG AND ADDITIONAL PREPARATION WITH FINISH TO BE INSTALLED. ER \ g \ Roao =- . �' --.. ° , --- - , s �u�, � .� ;,, , yq � ; W �£�;;� l �: w R _..�- . \ ��J E`� f� ....� �..rt�+�eJ"r°''�",'""�r�'�u4:/'ii/ '//i�Y� � F � v ""'' 3. REVIEW DEMOLITION OF AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH STRUCTURAL ENGINEER WHERE INDICATES SURFACE MOUNTED ` _ %' `� -. � �° � � � � � ? y„�,� �,;,; s' � � � � ���•% �H j��, .; �;'" ; .,, POTENTIAL OF ENCOUNTERING BEARING MEMBERS OR REINFORCEMENT EXISTS. NOTIFY ARCHITECT IF EXISTING � FLUORESCENT FIXTURE wi��ow coRE m . . F CREEK ROAD ; : �,.. .. %h >iq�,<y.,.. w u. ,. �q E<::. ::;t�,,.....,...,..,r 6,.:,.::::.:�_..'::,:::._:.:_:y..s . ASSEMBUES DESIGNATED AS RATED REQUIRE MODIFICATION . _ � � �,_,•, � , y yy : ,�,u � � , � � � : : ; SS ROPD �REST q�AO WILLOW PLACE c _. _ � '.�;v;.,..y.,,',.,; ,, ,, ; , 'u�A�' �y �`�-�'s,S ew: „„y �H,,,,.�..,,,,...»� � "� ,,, . "�'�,v �,��� ;r,� 4. THE GENERAL CONTRACTOR IS TO COORDINATE ALL WELDING VENTING, AND TIMES OF DEMOLITION AND FORE R y ,,,r.,.,. �' •:�r"`•" i...T--�, ' � oyO .g� , f y""' o r ; -, ,.. '..,.....�......»....,... ..,,r t. <::.. �-.3'i;`^.w;""? a CONSTRUCTION WITH THE OWNER AND CONCURRENT OCCUPANCY OF THE BUILDING. R HANSON R� gOP� A - �""� " ""` ' , ,`,, ����� ,. : ,° � , ,=;,� °: ��`; .� ..,., ".,,.' � 5. CONTRACTOR TO CAREFl1LLY REVIEW AND ASSESS THE VARIOUS SLAB CONDITIONS AND COORDINATE FLOOR �CK�Ep�, cy � o ;; "� „ "" " -•• �"�� ��, ��t � ?g � ��..,;µ',,,.i u ,,��, r-iu ,iqi��4 's, ;, s ..>.si%�f '. a ` �� ,�, ' RCP NOTES: 'E �C > - �q� �� ' ' N PATCHING AND ADDITIONAL PREPARATION WITH FINISH TO BE INSTALLED. RpAp �A��� ° o /;> � •�- � � � E �:� '��� x �.�,-° n .,,',r��� � ° �' ir� �� ':' '°'�""""' �w......i � �" X . //h.5�./ . v/h S ...�� ioi -.�iii p ,,... y 's. i � :..A,. / �iiii//,i. �,..,,.iy -,,,. y5 , ," � . � ° f, � f� .l�. ;��.,,^` � - .,.. ,,.,,p.,,,� 6. FIELD LOCATE ALL UTILITIES UNDER NEW CONSTRUCTION PRIOR TO EXCAVATION AND RELOCATE AS REQUIRED . 1 . CEILING HEIGHT TO BE 8' -0 " A. F. F. UNLESS NOTED OTHERWISE. NOTIFY ARCHITECT IF HEIGHT IS � � � , . �., . 5z E �;,� €�,�� GET OWNER APPROVAL BEFORE RELOCATION . UNACHIEVABLE. � � � � � �µ � � � �``�'�""�`�'"' � � � h � �y � " ` GENERAL INFORMATION , �'r• ; .,, . .. �' at.� ;, t r 7. GENERAL CONTRACTOR SHALL CAREFULLY REMOVE AND INVENTORY ALL ITEMS OF SALVAGEABLE VALUE PRIOR �.,` `d • ., • t�"�;;�;"'+►; �y�'���'°� � �� ;% / ���`�,°� , .' T„ ' �,,,,,, , ; ; '� ` ; ,,. �� TO BEGINNING CONTRUCTION . THESE ITEMS INCWDE, BUT ARE NOT NECESSARILY LIMITED T0: 2. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF LIGHT FIXTURES, REFER TO ELECTRICAL DRAWINGS FOR M�<< cR ; ' :,, � -- - ;��; �i ���, ' s ? s--piy�;u, ,�;. ' � �� k ' "s..;; ..x� r„� ,� r...,,,.; ; . � -_,.,,i :;,;,i;-�;;.�sa �;"w,� - LIGHT FIXTURES FIXTURE SIZES AND lYPES, EXIT SIGNS, SPEAKERS SMOKE DETECTORS AND ADA REQUIRED DEVICES. R4eEe � , ;;.. . �';�5 � w ; ,:_�,,,_,,;� :€ , � ;, �, , - ,�%,;,�,;; , „ . .. - LIGHT SWITCHES r � ;, � e, t v sa.rb� ��>,i s ,• _ , .,.: . ,,,,,.,,., �,.. � ,.,,,w,.� �.',ti,..,,,,,,,„.,,,.u,,,,. :..,�.,,,;.. � ,....,,,,.. ' t - THERMOSTATS 3 . REFER TO MECHANICAL DRAWINGS FOR GRILLE SIZES. '; _ ., . �� t� y i � � s i � '` ° % y��" ' w.,_., �"��;,,,,,�w,,,,,,,,,,,,,,,,,,,,,. >,,, ,s ,,,� /x,� , : - DOORS :........, , , - DOOR HARDWARE 4. SPRINKLER HEADS TO BE CENTERED W TI�E. `'""""`""""""'"""""'"'"'°'""� � ' ° � � s� °� �i �% ;s DATE 2 APRIL 2007 - FIRE EXTINGUISHERS (INCLUSIVE OF CABINEi) DRAWN BY CD - PLUMBING FIXTURES AND FAUCEfS 5 . CENTER GRID IN ROOM / HALL WAY. - EXHAUST FANS - TOILET ROOM ACCESSORIES CHK D BY SN ANY ITEM BEING RE- USED IN NEW CONSTRUCTION SHALL BE CLEANED AND TESTED (WHEN APPLICABLE) PRIOR TO PROJECT SCOPE MODEL FILE AO-O.dwg REINSTALLATION. 8. CONTRACTOR TO PROVIDE AND MAINTAIN ADEQUATE PROTECTION OF ALL ITEMS AND FINISHES THAT ARE TO OF WORK REMAIN FOR THE DURATION OF THE PROJECT. DAMAGED ITEMS OR FINISHES ARE TO BE REPAIRED OR REPLACED COPYRIGM 2007 BY WVIS PARTNERSHIP P.C., ARCHfiECTS BY THE CONTRACTOR AT NO COST TO THE OWNER . SHEEf NUMBER: A0 . 0 o. DEMOLITION NOTES AND PLAN LEGEND o REFLECTED CEILLING PLAN LEGEND o'o VICINII'Y MAP �� � P� �II�IIII��III��IIII�IIIII�II�II��II��iII��IIII�III!�'I�III' °.P�' PRaECT # osa�e.00 o � : a . GENERAL REQUIREMENTS summ.r�► or wo�: Interior Architiectural Woodwork: Acoustical Panel Cellings: Ths work oonel� of Inbrbr rsnowtlon wllh rt�sd�aniai end ekctr�el worl4 ae descrbd In fhs Contract Docisnsnls. Submlt Shop Drawirp� and Samplas �psclllsd. Submllbal b Yx;Mrds �p/swsmbly BubmR Product Data and MamrMl Sertiplss. ' msthods� locetlom� dimsralom� 11nhNss end roupMn ior Md�E dsvices. Acousticsl Pensl Glllrpt: Comply wllh ASTM E 1284 for Clss� A mebriels� es dsE�rminsd bY �G �� P�+� P�' ASTM E 84. Conlrecfio�s Uss of PronY�: Quallqr 8lenderd: Arohfbclural Woodwork IrntlWls'o 'A�hltscWrel Woodwo�k ti��aAty 8fendards.' Mebrleb: Cslllnp tlN and prld are nsw. . Durinp oonstructlon� Contiac�or shall haw IImIEed ws of opeos Indkxtsd. Conhactoi't ws of promiss� It IImIEed ony by OMrt�sr's dpM b perTam wak or employ dMr AWI 7yps of Cebinst Constructlon: Flwh wNiay. WIC CAnshuctlon 8lyls: Styls A, Fremsls�s. WIC Door and Drawer Front Styls: F1ueh arorley. Celllrp 8wpsnWon SYsmrtM: contracEors on portlons of proJ�ct �ePs bstwesn doorddrawers to b� pusl and ortl�oponsl. G�roct-hunp .wpsrwbn .y�tem, witl, UMertnsdlet�duqr .trudurel da..11lc.tlon axord�p b ASTN+ C 836. ' , - � A rc h i t ts Slzs atmchmsM dsvlas Tor 5 tlrnw fhs dsslpn bed Indlated In A37M C 896, Tabls 1 , Dlrect Hurp, u�le�s otl�s 6�deeMd.ce Payrt�snt P�oosdusr. �r' ano�coeted cerbornstesl wiro hsrpsn, braces, and tl�s complylnp wllh AS7M A 841 (A37M A 841 N�, Clsa 1 slnc ooatlrp� w1t bmpsr. Herdboard: AHA A136A Subrnit a Sch�duk of Vtlust whldi broab dorm ths Conhact 8um Into at kest ons Ilns IEem for eech technical 3psd�cetbn Fi�edk�p. CortNsEs fhs Sd�wduk af Veluos �lum-DsnWqr Flb�rboerd: ANSI AZ082 I��: wRh ths Contradors Con�truCUon Schsduls. Partldsboerd: ANSI AZ08.1 � Orads M-2 CISCA's 'Cslllnp Sy�brt» Fiandbook.' Hetdwaod Plywood end FaCO VN�ssrs: HPVA HP-1 CISCA'a 'Recamr»ndetlons tor Dlrect-Hunp Aoowtical 11N end layan PanN Cs9lnps.• 8ubmk 3 nob�d copM� of �sch Applicetlon 1br PeymsM on AIA Documsnt 070?1709� In eocordence wlth fhs adbd�� �stebl�hsd In tl�s Aprosrtwn A87M C 838� 'Stendard for Csllinp 8wpsnslon Syst�m In�eqatlorr.'oJsct. For ths Appllatlon wbmllEed at Subsfantlel Complstlon, wbmR peAlal rekesss of Ilsns from each wbcontractor or euppAsr for wfam artiounb we�s rsqukitlornd on ths Hlph-Proauro Lamineb Onds: O�ads 51-0sr»ral Purpo�s (H08, nornY�al tldda�sss 0.060Y1 .2mm} U.B.C. Standerd 47-18. P�� PeYmsnt Edps Troebnsnt PVC edp�s B metch avallebls tor cou�sr Isminab: roter 10 drewinpe and cut on ceb6�e4 suKeo�s. Menulecluror. Arm�honp Ce0lrpe ?801 oLAI� 8T.� 87E. f100 CountsrEops: Pleatic Laminab by WlboneR Laminets or pusl. .W8' fhlck. ACT-1: Arm�trorp squen Isy-IN� Clean Room VL 24'x48'x9/4'� wllh 16/18' P�� � �d � M� G�• �1.l�6 F�1� Coordinatlon: CablMt Intsrlors: WhIEr MslartYr�s. Ptoprees msstlr�pt wlll bo hsid at P�oJ�ct slEa svery two (2) wesks. Owner� Mchltect. Contrac.�Eor and �ech subconlra�,�EOr or olhsr � coraemed wMh cursrK propsse or Conted Adhs�lvs: Provlds Lamineb manuracWror recomrtisndelbn ior ths ePPtlatlon. 0�261AAIN 87REET . l�I1T C101 im►ow.d win, aanni a 000rdinenon a rua,re �, snen aa�,a. MlnuEes of sach rtwstl w�n b. �,. p,,,,,,,c Plestic Ismir�ets to ba epplisd to all e�wed wrfacss unls�s otl�snM�s nobd. Caulk all Jol� whsre ce�ework msab wap. seam +w d � es ur,d«.ms or u� Concrete To In : no no �.parsa ey co�escarena a.m�,oea b vi PP 9$ �w�os, caow�oos�eaa Contrat.�br to provlds propr�a tchsduk at each OAC m�atinp Indkxtlnp proJsct work ior 1ha neod tlrss w�sks. Cwework to bs Installad kvsl. Undsisids of uppar cabinsb to bs Installsd et 1�ar ProMds sslFldvsllnp undafayrtNrrb complylnp wBh �s rpulrort�b of A8TJI C94 awr axistlnp beas sleb w as b praNds e �rtioolh m►d Iswi wlaa m 970.i�E.eiEO F.Y70.926.liM P�� �� e� Pe�� roalw finlehsd floorinp matsrlala. Rsmove dlrt, boss metaiel, dl� oroaoe� PeiM or olhsr coMeminarns fiom s�dalnp concrsle Nab NevM�p e d�en wieos 8ubmiftat Prooeduros: to rocNvo toppinp sleb. Rspaly dl cracks In sxatlnp corxxsb floor slab to minlm�e telsprsphinp. Prlms �xlstlr�p lbors In e000idana wMh hs roqulrortisnb coo�din.ro w�nee� �er.no�, wm, � scnsau�e, rab�+cenon ��a-nm.., wnsr w��usa end ec�w� n,st rsaur. .s�usnnei o�suons• Cabinet Hardware and Accessorles: of fha manufecluror. �ow.i noor � proauo. a en�rwd wnecs mss oe trowsi medw, u�ira,n in �eonure ana e�ence and � n,e raiowr,� No �nslon oT Contract 71ms wlll bs euBartr.ed dus to felluro t� trantmk wbmMEeh In tlms � pertnR processlnp wmckMly In etMnos of whsn rtiebdsle aro roquhsd In fhs Hlrpss: Blum 708500 FS FO or equal; MouMlnp Pla�e 175H7100 or equal �olarsnoss whsn bstsd In accordence wMh ASTM E 1166. Wor1c. Puils: 4' BrusMd Wiro pulls. Ivsa by Schlapa� No. 197 U832D or equal. Menufeclursr. Ardsx. lnc. Propere wbmltfale by plednp e psrtnansM lebal on sech for ldsMMcatbn. Provlds label to rocord rovlsvr and epproval marldr�ps and ecUon �eken. Induds ths Tdbw4p Drawer puldss: Blum 320 M 8 Blum 125 dspree opsnirp or pual. IMonnetlon on ths IebN: La#: DNc Tumblsr �rllndsr Cem L.ocks. Natl�orel Cem Lodcs or equel. Pro� �� �E�sd��Fln^� F���haldwere, provlds 11n1�h thst canpllw wlth BHMA A168.e8; provids BHMA 819N815, BHMA 828N3 ZBD, BHMA 8Z5N8 26, Reslllent Wall Base and Accessorles: DeM Furtlnp, Bloddnp, Shlms end Henpfnp Strfps: Flarns-RstardeM SoTlwood or hardwood lumbsr, ldln dilsd b 15 pwosrd moNLn �t 8ubmR Product Data and Cabr SampNs. Nems and Addrses of Conlrat.�or At oomplstlon of proJsat, dsliwr to Ownsr et Iseat 10 Ilnear fsst Tor each 600 Ilnsar foat or fracllon tlwrsoi, of aech typs end color of rsNllsnt well baes Narris and ndars.. a subcw,bacEor .ra suppllsr Jolnt Sealartts: �"'�°��d. Tltls of Approp�iets Technlcel S Provld� resllkM rubbar well bas end acosnorNs ea �cMdulad on diawlnpe A7,2. P� �es�� SubmR Product Detia end color 8amplet. Apply reallkM rubbsr well base t� walle In 80 feat knptl�s, cdumns� pllesbrs, wsswork, and othsr p�m�enent f�ros In rooms or ereas whae baes le Product Deta: SubmR (8) fhros copiss and medc eech copy � show appllcabls ctiolc�s and apUons• ComP�blllly: Pr�vids Jolrn aaler�� lolrn Allsrs� and other rolated mebriels thet ere comPetlbl� wlth ons anotMr end wMh Jolnt subsl�a0eo wdar ssrvlos and ePP�albn �squlred. Fortn waA bsss oortwA irom ttralpM pkoss. IneEall roducsr strlps at edp�a of tbo�lrg at dhslmier rtiaExlals end ao�oaed aonaste tbaa. condftlone. Roppa No. 177 71k - Cerp�t JolMer bstwsen tlk and carpst Roppe No. 188 roduar et VCT �o shset vinyl4anWtlon. Shoo Drewirne: LaEea Seelent At Pedmstar of door fiamas� plumbinp 1bcWros end ceesworlc to welle (rocsss baed so tl�at daer Wlicons b�ad can bs appY�d on 1oP} P�oora AC-20 ona SubmR nswly prapersd InTom�atbn drawn b �cela. CoMnclor bo Indlc�Es d�vl�tlo�a fiom Conbact DocunMnb � Indudlnp emr addande or chanpe b� fha scaps of tha PeR eaylb latex ceulk or equal. alpinal scop� of work. Do not ropioduos Contract Documsrrta or copy stende�d Irdortnetlon. SubmR 1 ropiodudbls q1M and 1 blus- or bledc-tlns p�r�t an �I�ssis at keat Elestorristric 8eelar� Compy wllh AS7M C 920. T��6: &1/2 by 11 Inchsa but no lar9sr tlien 30 bY 42 Inchss. Mehltec:t wIA rsLun ths rop�odudbls p�lnt Acryl� Sselent �r�Pert, ran-eep� wlvaM-rolseos-curinp acqA� trrpoymsr �salent comPM�G wllh AAMA 808.8 or FS 1TS-00230� or bolh� wllh capabllly� whsn �esEed As apscllled on A2.0 Sampks: SubmR (8) thros eampls finbhse as specllled end IdeMkal with ths mebrial propos�d. Whsro verietlons aro Inh�nnt In fhs mato�iel� wbrNt at Neat (3) tlrse unlm P� AS7M C 719� to wlthstend plw or minue 12.5 parosM e��enpe In Jolnt wldfh �tlnp at tlms oT appNcatlon wltNout TaWnp. Settlnp Me��rials: Hyd�ortNnt 'SlrplaFl�x 918' letax modlllsd dryest mortar end weEeiproa�f rtiernb�ar�s by Boatlk FV�dlsy. thet show Ilmlts of tha varletloiu. P�vids shop drewinps for ths Tolbwlnp IEsrtw: Doors end Framss� Door Herdwars� Ca�swak, Cesswork Flardwaro� Ca�wvak Flnblws, �MlaEmulsbn Seelant Or�part, rar►+ep� mlldsw-realNeM. Pelntabls� ecryllaertwrMlon �selerrt aomply4p wNh ASTM C 894. Existlnp 11oor to bs P�PP� to Inwn flwh� �rtiooth floor. Fbat 11oor wRh conslstsM sbpe b floor drelrM wM+s roqulAd. GTOR RUTAA � ABBOCN7E8. 00. SIIIcon�Emulslon Soelsnt At ap sMp of Inbpral stisst vimrl 11oor and edleceM wrtaa. Product comPMnp wlth ASTM C 834 end� aospt for wNpM bee m�aeixsd Ps�' 1lQO DONEIt 87i�T. aUfTE 2 Palnt, Comsr Ouarde. Wall Covainps� Acowticel Cellirg 711ss and Orid� Grpst, Beas end VCT. Induds product �ms or rema af fhs rtbnu�eC4rsr. Md�lact wlll rovisw ASTM C 792� wlth ASTM C 920, tl�at socommodetes JoIM mowmsM oT rat moro than 26 ps�eM In both sxten�bn and canqss�bn for a fo�al of 60 psrosnt Dow C8�8t. LI1I�WOOD, CO lQ216 each wbmNEal, mark es appioprlete to Indlcets actlon taksn, end rotum copks Isss ons reEalnsd. My 8ubsltluflon of ineterlals roqul�s ConUacbr b prwids da�a Indcetl� Comirp 790 Silbons Bulidlnp 8sderrt or equal. product pulvekrxe� submMEala w10 not bs rovlswsd It Iniomiatlon M not provldsd. Acowncel Sealant Non�ep� Pelntabls� non-,talninp, lat�x MeleM cortipyk�p wBh ASTM C 834. Submk Product Defa and Cobr Semples. Acowticsl SealaM for ConosaNd Jolnb: Non-dMnp, rwr�herdanlnp, nonsklnnlnp, non-stalninp, punnebk, �ynth�tic rubbsr �salant rscommsndsd for ssalNp Inbrbr Prop fbor a roqulrod end In�ll e �elFlsvellnp compound (oae Concrsts Toppirp 81ab asctlon above) to provids a 11at end Isvel MNlwd surieos. (SgUEIFtEVISION DATE NO. Tsmoorerv Fedlltlss end Controk: oor�cealsd Jo1Me t� roducs treramisslon oT albort�s wund. In�allsr Qualllkxtlont: Enpaps en �xp�risncsd InaEalisr who k artlllsd by the Floor Cowrinp IratalaUon Baerd (FCIB) or who an d�rtionstrals Stisndardt: Comply wMh NFPA 241 , 'Stenderd or SeTspuendinp Constructlon, AlEsrotlon�, end Dsmolltlon Opsrotloro; AN81 A70 Ssi1M Nands� for 'Sebty RequNsrnsnb compllence wMh FCIB certllkxtlon propiarn roqulrrnwnb. TOV CODE REVI EW 1 JUNE07 for Corntructlon and Dsmolltlon'; and NECA Ekctrlcel D�slpn Llbra 'Tsmporery Ekctrlcel Fadlltlss' ENd�kxl Nrvlc� N�eA bs � aocadence wMh NEMA NECA and UL Hollow Metal Doors and Frames: �� lhat havs 11arr�-sProad and srtiolcs-dsvsbp�d rotlnp� of 26 or Isss and 460 or Isse, rNpsclNely, wNen fesEed exddMp �o ASTM E 84. Comply s6snderds and ropuletlons for tsmpaary slsc4lc aarvkx. Install �srvbs In complanos wNh NFPA 70. SubmR Produd Deta end Door Sclyduls. wHh CRI 104, 8�ctlon 8, 'SI1� Condltloro. ASI #1 13,1uN07 Irrte�lor poor Fiamss: Provids unlb wlth mlEsrod or copsd and contlnuowy weldsd oomsrs fom�sd irom 0.0478-Inch thk;k, ool�ioYsd t�N for opsNrpo 48 IncF� or Nea At complstlon oT proJsct, dsliwr to Ownsr full-widlh cerpat aqual to S p•rosrn or each typs and color cerpst Int�alNd, psdwpsd wMh protecllw oovsrinp for Tsmooranr UtllMles: In wldth end fiom 0.0598-Inch stssl for openir�ps more tFmn 48 Inchss In width. For rated doors end palrs oT doois oNY paAde R�savY d�+4r Imock doMm hollow mslal u.s a u,. owr,.r. �a.n san Trem�e at ell othsr �Eandsrd door iremss. Provlds ons 11oor dl Provid� cerpst as �ch�dulsd on ths DnwNrpe. �G �Y TedlltNs wlll bs p�rmllE�ed� ao lonp a fedlltlss aro cNensd and malr�talnsd In e oondllon soospEabN b fhs Owrrr. At Sub�antlel P P�l�b� 4 msfel Nud anchas Psrlamb• Comply wlth CRI 104� 8s�.ibn� 'Dinct OlusDown.' Cort►Plstlon� rs�tao 1Mss tadllll�ea � �s condftlon prsvalsM at th� 1Ms o( INtlel we. Proparo doora end tremsa �o rscsNs rtwAked end conaelsd hardweis sooadi�p � 8DI 107. Manulaclurers: Lssr, rtielch eoddtr�p. Tsmooren► Contiob: Comply wllh NAAMM'a 'Mstel Flnlshss Menual for Arohltstxure and Mstal Producb' for rscommsndetlone rolativs to appylrp 1k�lelNS. MelnEaln aocbtlrp flro piobctlon uMll rtadMsd �yat�m of 11is�piotectlon Is In plaos. FecEOry prims elt wrTecss (ovsn dry piimsr ons m� m6Yrrwrm} Vinyl Composition Tlle (VC'�: Provlde bmporery berticad�s� wamirp alpns, end Ilphb m protect tlw publb and constructlon psr�onnN irom cor�sfi�cllon hezerds. Pubm�� Detia end Color SampNa. Wood Doors: rop roquh.d .na �n.mn . ..K.kvs��np oompw,nd (.« conasa ToppUp s�ab ..cnon .bow) to pio�vlds a +lec d,d Isvsl nnbned wKeo.. BubmR Product Deta and door �cheduN. Provids 1/8 Ir�ch raminel paups, l2 In. x 12 In. Artnsfronp MultlColor 11k In msstlrp ASTM F 10@8, Clws 2 - tlrouph-petEem. Colow wBl bs aslsc�ed irom Produd Reauliwrwnb: Product Oak wRh clear 11nhh to ms�ch aodetk�p. ths rer� cumsMly evellebls from Amis4orq World IndwtrNs, Inc. In Wdawa d�sipnaled. Ths Ownsr and NohlEect may consldsr wbstltutlons of �P�Md mataiels whidf provlds a savinps In Contract Sum endlor TYns. Ths Conhact Sisn end Thns aavlrps ehell Soura Ilml6etl�ons: Obtaln 11ueh wood doors throuph ons aouroa fiom a Ni�pla rt�erwfach�r. Ins�ell tlk In strkkt aocordenos wlth menufecWrors wrllEsn Ir�truc�tlons over approwd wblloois wlnp ths Vk�rl CompoNllon 79s Ins�allellon Sy�lem wMh b dMeY QualNy Sfandard: Compy wllh WDMA I.S.1M04. Tu�FaW�ed (5-89) (5-700) (5-730) (5-615) AdMsivs a iscommsndsd by ths manufadursr. Clsen, aal and wex p�r rnsnufech�a isoommendatbrr. bs IdsMlllsd at tlms oT wbmlBal. Ths roqusat for wbstlWtlon ahsll bs wbmltEad In roasonabl� end Ums mennsr for rovl�w� se not m contructlon. wbmllfals sheU Includs produd �Miortnatlon. test deta� eamPka (M sPplk;ebls� dallvsry Utns� end oost IMormetbn. It dssrtNd eoaP�abk hY ths Ownsr and A�hlk�x. lhe Feclory Flnlsh: Comply wlth WDMA tlnbh requlromsMs. Flnish doas et tscloiy. Finish: VYDMA TR-6 csfalyzed poly�raAhans. Staltdnp: As asl�cled ltom me�+u(ac4rsr wbstlWllon wbmllEed may ba wed by tlw ContracEor. Acosptence of 1M aubstlhitlon by ths Ownsr end MchlEect dose not rslisvs tlw Conbsc�or of rNpa�Nqr In s6endar�d odo�s or cusEOm color tn acca�denos with tM epprowd eampls. FacEory flnNNsd doo�a t� bs In�EaINd Jwt P� �o arb�u�id aort�pistlon. Submk Product Dete and Color Semple�. psrTormena or workrtanehlp In rolstlon �o ths wbstlWtlon. Tha roqulrsd wertaMks o( any IEsm of constructlon diall not bs modAsd by wrbsUhitlorn. Exeminatlon: Exemins doors bsioro henplrp. RsJsct doors wMh d�fecb pMor m herpinp. Pinc�sd wRh Irnteiletlon ony a11x uneetl�faclory oa�dllorM have bssn cortacf�d. Prop 11oor ae ns9ulrod and Install e �NFlsvellrp compound (tw Corxnste TcPpInO Slab a�ctlon above) m qovids a flat end Isvsl fiNNsd �urTaa. Irotalletlon: Inshll doora psr ths menulacturaa wrriEen IrntrucUon�. Allpn dl doors for unlform dsarsna at eech �dpa. Rsstas fec�ory flnNh b�Tae In�eAaUon If 1Ntlnp or Insteil In strlct ecoordana wllh manuFecWrors wrlt�n Instructlons wRh e minimum oT ssems owr appio�wd wblloas uNnp fhs ComRwrdsl Mnyl-Bed�sd Q � Q Examinerion and PrsoersUon: machlnlnp le roqul�d et proJsct dEa. A�wt dl doon t� wrinp end opsrals treely. Installatlon 8ystsm wlth (&675) (5-240 Epo�qr) AdMslvs end h�at�weldsd wems es r000rnmsndsd by fhs menuhchusr. Ine�el fllst ahip at kfmrs�clbn ,r��C., Ezamina wbstrete� end oondltlorn tor complfana wlth manula�.turera w�ltsn WartaMy: Provlds tull IRstlrt►e manu(a�tura�a wartanty tor In�xbr SoAd Cors Doas. ot wall end tloor; �os oT strip not �o �xeu�d past wrtkal wKecs� mllro Mslda ooms�s. Cisen� esal end wax psr merw6sc�wera rooam�sndatlons. 4" ,r �r'^ tiqufrsmsMs Indudinp� but not Ifmlbd to, surlaae tl�at ero �ourd, Isvel end Plumb� wbstretiee Menufaclunr. Marshllsld Door Syamrtr � Menufeclursr. Artnstionp M�dlnbch; as� FINeh Sd�eduls. ' . � �`� � :;� \ wRhin In�tallatlon tolsrenar, wrfeoss that ere amooth, d�en end fros of dol�tsriow wbsfenoss; end appllcetlon condltlorr wll� ernAronmsntal 6rNb. Do rat procNd wMh � `' _ ` In�llatlon uMll urnaWtecEory condltlons hew bssn con�cE�d. Propen wbstrsbs and odJolnlrp wAeas socord4�p b menufech�rera wiMEen trrtrucUone. ;' ,a , _ Access Doors and Panels: °��, ` . :' -• ; CuWna end Petchl�: SubmR Produd De�a.PS Sheet Vinyl: <. . - BeToro cuttlnplpetd�inp sxlstlrq aurTeoss� sxemins surfaces to bs cut and Detchsd and condltlont under whid� a�tlrp and psEchinp b to bs P��. Teks conscihre Stssl Shss� A37M A 386 commerdeFquelfqr, cold-rolled �bsl shsst wifh beks�on� nist-InhlWtivs prirtier. '�� ,� � .. �� � ; actlon bsToro procsedinp B uneafs condltlons ere eraouMerod. Protsct existlnp cnnstrucUon durlrp a�ttlrp end Petchtrq to Prwerrt dameps. Temporaiiy caver opaNr�pe TNmk�s� Flush Aocea Doors tor Oypsum Boaid: Units conshtlrp of irems� conaelsd edpe trlm� door� herdwero� and oortiplylnp wlth ths folloNAnp requlrwnente: SubrNt Product Deh snd Cda 8ertipks. � � -� � , � 11oor a rsqul�sd �nd Y�II s �elfasvsllnp oonpound (� OonasES Toppkp Slsb �sclbn �bas) �o pwid� s h! �nd NvN fiWisd wfeos. '.:, . `. . , . Frems: 0.0598-Ineh thkdc sbsl shssL P�P nd '� ' wlwn not In ues. Petch wllh durebk seams tl�at ere as Imlelble ae poselbls. lnspsd end tsst patchsd aiea� b dsrtionshabs Ir�eprtly of ths krtalletlon. Do not cut atr�x��al ..,::.;. ,-.�_.:::.-� rrwmbsr� wRliout prlor writlsn epproval of MchlEsct and StrucWral Enpinesr. For Petch�nG Provids metsriab wlwes In�Eallsd p�rlbmfanos wlll pud or turpaee fhat of Door. 0.047anch tlddc sfesl sl�et Iroh1 In wlat �na wHh mrwi�� wAtem Ywtrudbn wNh a mWmum d �wrtr wsr �pprowd ��1bo� wlnp ths OomnMdtl VYryFB�d��d hrld�tlon Concealsd, �YPsum Boerd Edps Trlm: 0.0269-Inch zlnacoated or geNenlr.ed-sbel �hest with feos 1lanps fomisd fo roalw JoNt aompand. $Y� � (�� (� �) Ad�hrs �nd Iwt�rsld�d wrtr � ncamisndsd �Y IM mmuf�du�r. InNel 111st �hIP �t ir�le�ssclbn d wd md 11oor, bs of arlP sxlsnnp metsdals. For sxpo..d witecss� provlds or nnlsn metsnab to vlwsly ma�cd, .odstlnp ad�aca,t wrteces 1� tf,s tunsa aoee� posslbls. H�rqs: concse�sd aprlrw pin or oonnnuow type. not to eeaena a� wNal wNsc.; mtrs rra. comas. P�o�na. msW oov. cea .�a auk to waf. as.n. ..al �a w�oc wr m.n�4a+r. ncommend�acrr. Installetlon: L.ocke: Scrowdrlvsr-opsraEed cam. Mmil�chrsr. AmWronp AAsdinleoh Comply rvllh manufadursi's wtifbn Inetrtwtlons for InNallatlon. Mchor eech product sscuny In Plsce, exurately locetied and aYpnsd. Cleen ao�o�ed wrfeoes end prolect . r� �. H ��, �.�. w�o�. +� n.a �nr�. DoorHardware. Palnting: wartanty: s year r.ae�r or nplaosrtMnt a asrocuve oon,por►sr�. ur.tims wertaMy ror ropladnp .eopkp �.vws �d c�l�d�r houekp. submn Froaua �em and pr.pered caor sartipiss. flnel ClsanMn: Submit Heidwaro Schsduk. For 11re�reEed oan�npe� Provlds hardwaro bsted end Ilsbd by UL or FM (NFPA 80� On paNc aodt dsv�e0. p� UL or FM label k�Cetlrp At compktbn of proJsct, dsllwr m Ownsr e 1 yel. (8.8-L) contielnsr� WoPedY labslsd end ssalsd� of each cobr and typs of 1hYh ooat palnt wad on CNan �ech wKaos or IEam ea Tollows bNoro r'eQusstlnp IntpecUon for certllketlon of Substentlel ComPkllon. 'Flro Exlt Flerdwers.' All ha�dwaro sf�etl be ADA oar�ptlent Pro� Door Hardware: As Indicebd In ths Herdwaro SctNdul. on ths Drewinps. Non-romowbls hlnps pins Tor �oA�rlor and WbAc Merbr ao�o�ue• �� Rsrt�ow labale tl�at aro not P�� Cyllndaa wllh 8-pin hinbkrs. � an s 11ist ne quellqr r�t mets�ial vadow np typss r apsclAsd as on Clsen traimperont metsrlals. U�dudlnp mirtas. Rert►ova aocoeee pla�np campoir�d�. Flnishss: As �pscMad on drewk�ps. Comply wllh Pa�nt manutacEurera writbn Insfnx;tlorn Tar wrfecs Pn�Peratlon� ernironmsnfal end aubstrsts aondtbne� Produ�t mbdrp� end appllcsllon. Rspiacs chlppsd or b�ok�n pws. Ksylnp: Provids 4 d�anps kaye Per lodc� Provlds 8 mesbrs. Clsen e�oesd finlshes t� a duet-iros conditlon, Tros of stalne, Nme and biNpn wb��oea. Manu�eclursr. Schlepe Evsis�t R�stricted D Serlas Levsr Herdwars IrMerbr Palm ScMduls: ���� L�avo concr�s�s floor' broorn clsan. vacuum ceipsted wAaos� end wax nen�snt noainp. GI8ZI11Q: m 8ubmR Product Da1e and Semplss. Compy wlth vrrllban Ins4ucvor» of pk�ss product msnulac4irera� FOMAs 'Ole¢k�p Mlaru�� and pubticatlore oF AAAM, LSC3A, and Wet bceticns: 1 coat B28VU200 Pro Mar 200 LaEe�t wall qlmar, l.1 mYe dry fYm tldda�ses. u � Medical MchltscWrel. Mechenlcal end EkcUicel Punddlet SIOMA. z coea se�lvvz .sr�.s i eeovz�o ceesysc n� aad, a mns �r com. Piovids the MchlEect wMh e Pro-P�nch Ibt of IEsms yet �o bs complsbd prbr b isq��sst Tor hepsclbn. Wartarriy: 10 yearo. NorrWst locetlorw: 1 ooet B28W400 Pro Mar ,00 L,ate�c wall pdmsr� 2 mlls dry 111m tl�dawe. C enter Mlnors: Provlds bsvslsd edps mlmas et widlh spsdAed. CbNOUt 8ubmlt�ale: InEerior Windowa and Door LIEss: 1/4' Tsmpend C�Isn 2 coeb B9 Hsalth 8psc. Ep Sfwll, 7 .5 mil� dry fllm Wda�e�s psr coat. Reoord Dravrlrps: MelnEaln a set of Contract Drawlrqt es Recor�d Drawlnps. Mark to ahow Instelletlon fhat varlee irom fhs Wak ea orlpireYy W�orm. Fln �sted pls�s, 'Fir♦Libs' by T�chnlal dha P�oduc� or equsl. Doors end F�arrNe: operano�, .nd �mm�a�,o. c.m: o�a�,a.s aem imo a++r� arxi.B, wia, � roid«. rorroa.d .nsst r,rom,anon. Flreproofing Restoratlon: Hollow Mstal Frames: 1 coet B60Z �sris� K�m Kromik Unlvsisel AMEaI Primsr, 8 mlls dry 1pm Wda�sa psr coat. Cloaeoi�t Proosdune: Provlde msterlal maEchinp sxatlnp dertiepsd condltlon. Dowmsnt compllenos for ues bY O�m��G luriedictlon. Provlds approprlale du�t conlrol� wntAsllon or 2 coab B10 Heallh Spsc ssmFqloa� 1 .5 mlis dry 1Nm Wdaree psr ooat. Requsst 3ubataMlal Complstlon Inspsctbn ona tha bUoiMnp ars aompls�s: cor�minetlon rt�s�od�. Prep wbntab to aeeuro propsr bondlnp. Apply primer and propan product p�r menula�.iuro�'a r�carm�sndetbre. Rsrravs eny o�vasppy fiom Wood Doors: Factory Flnbl�ad - Stalnsd and SeaNd Adviss Ownsr of psndlnp InwrenCO chanpsovsr isq�b• e�aCSM Wrfaces. Corner Guards: sua„n R.cond �rawtrq.� �ntw�encs Manuuah, wanam�.s ana .knaer �ecad mromienon. Flrestopping: aioau�x �am: suen,n rne�u�aca,rsr. poauct aam. Dsliver sper� Perb� axtra ttock end drtilar Irnr. Semplss: SubmR 12' (9W.8mm) brp ampb of �ech nadsl end oolor sPedllsd� Indudinp �nd aP0. forA�I�IMcPs �pprovel. Documsnt aompllenos fhat eech oomponsM of psnstraUon fhrouph rated asesmby meboNss assmby ratlr�p and mssb or aoca�do ths poverNr�p Juiedk�lony tNtlrp Com wlth NFPA 101 for IMsrlor 1lnleh metsriels. Srtaks d�w Isn then 450 and flema sprsed of 26 or kn In e000rdsnos wlth A8TM E 84. �01"� �p �"D °�sy8�"1°' roqulrom�r�b. 8ubmMmis � Induds t�etlnp apsrwy end dsspn numbsr� se4uenca ot Installetlon. msthod ot aaallnp �rtwke or 11rs tranarrwbn. Pnpeiatbn at wileae PN � Rert�ow bmporery fac111tNe and controls. should b� Indudsd In ths crlEsiie for p�nstratlon of ducls� plPsa or condullt tivo�ph tloois and rsbed walb. c«��. n�i a�,a. MMIUFAC7URER: InPr� Corporetbn 160 Hiph Impect Comsr Ousid; mour�ted over contlnuow aluminum retalrbr. �o..a .�.o.. .n�a � r�.. or FI I"St F� 001' Touch uP� roPaU� r�plea end rostore memsd� mcWoeed flnlelNa. AAetsrial to bo non-toodc, non-oomalve� end non-canbustlbls. Pr�vids collar et ersas �u�ospl�la b rtioverr�nf. wrinklinp� chlPP�np� dboolorstbn� or otl�sr ImpsAecUora. Lep L�npfh: S' (50.8mm). Mpk: 90', 135'. Proflle: Hlph YnPect vlrM acryl� �bn bdud In Obtaln 11na1 Irnpsatlons from suCwrltNe hsvinp J�ubdlcUon• plea, raminel 0.078' (1 .98mm) thldc. Clea UA 11ro ratlnp, tested In eocordancs wMh A87M E 84. Extr�don: P�bble prah� Mkh. Cor�talne EPA iepl��ered ��� �� � �+Pa�Y� Metal Framing and Supports: Mlcno-Chsk ernlmk:roblal epsnt RetalrMr. Contlnuow 808&T8 aluminum rotalnar alonp sntlro I�rplh of cortiar puaid, mlNmum o.080' (1 .62mm) thidc. Nudear Medidne upon �.i�n a a requssc ro� n�,ai ins�cnon, Mchfbct wlll pra,�ssd wllh InspscMlon and edvlss fha Contracbr oT wdNlsd roqul�rnsnb. Stssl fiaminp aompor»rne 1br swp�ndsd and Tumed celllnp� complylnp wMh AS7M C 8�6 end ASTM C 764. End Caps: Ir�ecllon mold�d unR of oolor end teoclur� almllar b that d camsr puand. Arrenps for aech Instalkr of aqulprtisnt fhat roqulros oparatbn end melntenancs t� provlde M�ebuctlor► to Ownere A�^� 'Nee, ��w: AS�1J A o"45 �t.S iRi �i �i5 Arf j, �.i�we 'i zinc coeanp, eort �xnpsr� u.8rrc-uxn urac. iiva i Au�►"i iOn: inspec� wau sunacse to isanre aash ralls. NoCy 1M Ard�loect In wrtnnp K wall surfaoss aro not acaspbebls. Do rat bspin h�allstlon untll �' �V �em�el Flenpsrs: Wlro, ASTM A 841 (ASTM A 841 M), Claes 1 zlnc ooetlnp, �dt tert�psr, 0.182-kfch dartw�er. unaccepEebls oondlHona havs bssn corrscted. Ir�ll comar puards to wells securoy In eccordance wlth menufadursrs wrllEen kntivatlorN. Ir�all comsr Werremlae: CerrylnG Channals: Col�rolNd s�esl� 2 Inch�s. Querds exurstsy In bcetbn� allpnmsnt, end slsvetlon. 8ubmR wrllbn wenar�lss t� tlw Arohlbect prlor to ths dets cerUlisd iot SubstaMfel Complsllon. If tlw Ard�lEscCs CertllfceM1s of 8ubbantlsl Complelbn dsefpnates e Furtlnp Channsls: 7/8-Inch dssp, cold-roYsd d�annsls. comrt�enament dete Tor wertaMlse othsr fhen ths dete of SubsteMlal Compktbn for 1M Wak, or ae a dsslpneted porUon of ttia Work, wbmR wrll�en wanar�lse upon Sbsl ireminp for psAttlons oomPMnp wllh A87M C 846. Intlalletlon: �� � � �� 8tuds and Runnaro: In dspth Indk:eted end 0.0179-Inch thk:k, uN�se olhsrvN�s hdlcaEed. 8scuro mlrtors to wella In conoseled, tampsrprooT mannsr wBh �psclel 1lnpsra, �oppk bolb, or acrows. Set uNb plumb, laval and �quais at bcetbiw Rlpld HetShapsd Furtinp ChannWs: In dspth Indkxted end 0.0179-Inch th�dc� unlea otl�srwles Indlce�ed. Indkxted� exordlrp to menufacturo�a Instructlont for 1YPe of wbetreEe knrolwd. • Whsn tha Contr+ect DocumsrNe roqulro the Contrector, or tM Conhaceor end e wbcontractor, wPplkr or manufaclurer t� aocaa�e a �peclal wartamy, pisparo e wrluen Funlnp Bredcsts: Ac�wtabls �srtated�artn yrpo iebricated irom cortoslon-nslstent stesl �hsst 0.0.929�nch thk�c. Install prab bers to wllhsmnd a downwerd bed ot at Isast 250 Ibs, � ,�, � F „e. 181 W. Meadow D rive Pr�vlds doubla 16 paups studa et each door Jamb; �snd 1D strtx�ure abovs. Provlds 20 peupe aluds at 18' O.C. beNnd caeswo�k; paAd� 25 paupe stiuds at 18' O.C. • docums�,t n,ec conmins a�o�em �em,. e�,d asrnn�ceno�, roedy tor axeaitlon by 1M requlrod partlse. SubmR a dreR t� ths Ownsr, uuou�r, n,e a�o�x, ror a� sisswnsro; unka UL assmb y r pulros dll�innt p a u p s. W a l l P ro t e c t l o n: V81� , �i0�01'8d0 prlor to 11na1 sxeculbn. Whsrs nsw peAltlons ec�oln sxlYtlnp carntructlon� ths nsw 1lnlahsd Tacs �hell ellpn wHh the axl�tlrg 1lnlehsd tacs urYses noled dFMrwbs. Product Dam: SubmR manutaclurers product dete Indudlnp rrmNetlon Instru�ilon. 81657 At Flne� comp�on compl�s (2) two cop�ss ot eech nqulrod wanamY v��r �cecuesd by the Cont�acaor� or by ths contra�or� subcontrac�or� suppuar or �rer. G um Board Assemblles: Semp�ss: submn r x s� (�n.smm x 228.emm) aamp�e of each t�rps� th�ckrnes� cdor� end tpcturo to bs h��sd �br�4richro�ct's approva�. Orpan�s ths wamaMy documsMs IMo en adsily Nqusnos be�sd on eac�� 4echNcal 8psdllcetlon Headlnp• y� MANUFACTURER: In P� Coiporatbn SanperrolOT 8hsst Rlpld hlpMmpad eayllrJpoy�Anyl chbdds (PVC) 4-0' Nph roll poods. Thlcla�ses: O.OBO' . Requast Inspsctlon for artlAcetlon of Anel axsptsna end 11naIN PeY�►bM, onos fhs ToYaMnp are aomPls�: �YPwm Wellboerd: ASTM C 36� In thk,lmsss Indlceted, wlth manu�ec4rsr's �anderd edpes. TaxWro: Stander�d. Fumleh adhsslves aPProved bY Protectivs wallcavsMnp menufacturor. Fumish acosaory moldln�p bY D�� �� Rspuler Typs� end Type X whsro requlrod for 11re-roslstana-ratsd ae�srt�Wlss. We�x resle�ant. menufacturer to snwrs accurate matd� of colas� dlmansbns� and PhYs�a� DiopsMlse. Fumleh cdor�riatd�ed ceulk bY P� ���G SubmR Mel peymsM roqusst wlth rokese� oT Ikns end wpporUnp documentetlon. Mol�hire ReobteM Non-Ratsd Boerd: ASTM C 830� In thldcnaas Indk:ebd. Repular 7ypa end Typs X whsro roq�Yisd 4or 11ns�roel�anosaaEed apanblles. menufacturor to �nwre aawrate match of oobre. Induds Iraursnce arUAce�ea Aooessork� for InEsrior InWalletlon: Comsrbsed, edpe tr1m, and confrol Jolnb comPlylrp wlth ASTLA C 1047, fomisd from tbN tl�sst zlnc coebd by hot�lp prooese or SURFACE PREPARATION: Prepero wells In eocordance wlfh manufectursra wrlmsn IrutnicUons. Rertwus duM, drf, Oroess, oB, boas palnt, scek, and 3ubmR contont of wisQ� to Mel payrtisnt rollsd tJnc. APPN approprlets ecowticel and wetsr roslstaM welenb et all psnshalbrw and Jolnb. sxlstlnp wallcowrinQ. Rssurfacs unsvsn wall wriacss end dertu�psd wella. Saal watls wAh whlEs prYna eeel. On oomplstbn of n-Irwp�ctlon� McAlEsct wlll propero e cerUTlcets of flnel exsptenos. B ths Wak le Irxompkts� AroNEsct wlll advbs Car�tracEOr ot fhs Work fhat b Flnlahirg t�ypsum Boerd Aesambllss: In exordenw wHh OA-214� Lws1411n1ah� unlaes othsnMea Indk:ated� Lsvsl 1 N�Ish tor conoealsd aiaea� uNs�s a hlphsr Isvsl of EXAMINATION: Inspsct well surfecss 4o rocslw protective well�verinp. Notffy ths A�hltect M wall wrfeces aro not eoosptabls. Do not bspin YxtaNallon Incompleta or obllpaUons that havs not yat bsen fulAlled. 1lnith Is requlrod for 11re�rsslstance-rsted asssmbllss� and Lwal 2 flnbh whsre pansls brtn eubstrabs for tlk. uMll unecceP�bl� condMlons hew bssn aan�,�ed. iNSTUUroN: ir,.mn p� �i��� �o ,N.i�. i� e�o�r� wia, ��ur�a,�.r. �� i�.a,x+ion.. a� � w�+� er,a �we SPECI FICATIONS Sekctivs Dsrtatlllon: to pncondftlon Tor a minlmum of 24 hours at a tsmpsrsturo bstwe�n 65'F end 85'F bstoro Instelletlon. In�tell �hssis wAh faochrs nmNnp N fhs sems Unless oths�wlsa �ndlcatsd� dsmdlshed mets�lals becon►a Conhac�or's ProPen1!• �PN wllh EPA �epulatlone and dlsposel ropulatlons a� eulhotltfea haNnp JwNdi�tbn. dlrocticn ta' unMortn appsa�anoe. Conduct dsmolftlon wllfwut dlsruptlrp Ownsrs oxupsUon oTfha bulldlnp. IEsms Indlceted t� bs romowd end salveped remaln ths Ownsrs proper�. Remow� daen and pedc or aate IEoms t� W'otect eoaUrt dam�aGe. IdentlN oonbMs of aor�alner end dsllwr �o Ownsrs dsdpneEed �aps aAe. DATE 2 APRIL 2007 All IIpM �wlEd�w� tslsphons� Nsctrical� detia outlsffi� stc. Indlceted to b� r'movsd or r�bcebd shall be compktely nrtioved. PaEch and appy fY�Nhh Indkxmd. A oo�vsr plats wmnotbs .ca�mds. End of SpeClflcatlons. DRAWN BY c� SUbmR �Chlduk IndIC9tl1p propo��d NqUlflC9 O? Opll'Atl011B TOrlSIldlVe dOm01M1011 WOIk tD OW11lI't RYp1lMflmtlN� 1br roVkW p�br �D 6mR Of Wofk InCklds COOfdMl9tlOfl CHK' D BY SN for ahuEolf� ceppinp and oontlnuetlon of udllly asrvkas es roqUlAd� bopsthsr wlth dsTalb for duet end ndN conUd piobCfbn. MODEL FILE AO- 1 .dwg ProvldY d9tillsd aeqlwnCe of dsmolftlon snd romovel wak tD enwre unlntsrtupbd proproq Ot OYVnsrs orrelES opsretlw�s. ConduCt dsmolltlon wolk In mamsl'U1at wAI COPYRIGHf 2007 BY DAVIS PARMERSHIP P.C., ARCMfTECTS minlm� nssd for dlauptl�on oT Ownsrs namel operetlorr. 5HEEf NUMBER: MelMaln and protect exMlnp utllltlsa to romaln In ssMa bsToro pioc�sdlnp wlfh dsmolltlon, pravldlnp bypess oonnectlons b othsr parb d ths buNdnp. Locste, IdsMly, shut oR� dlsoamsct, and ceP otf utlNty �s�vk�s � be dsrt►ollshed. Protiect rortwlnlnp wdls� oNNnps� tbors� end s�o�sd tk�iehes. Eroe3 and n►ak�aln due�oot Pe�tltlons. Cowr end proEact rsrtialnlnp fumlluro, fumishlr�ge, end equlpmant Promptly pek;h end repelr fwlse end daeiepsd surfeces af bulldlnp cau�sd by dsmotlllon. Res�s ■ expossd 11n1�s of pstchsd eroes end exEsnd 1lnlsh rsttoratbn Into romelnlnp edJolnlrp oa�structlon. Promptly r�movs dsrnolNfrd rtieEeiials fiom Ownei'� propsrty and kpely dltpoN oT Thsm. Do rat bum dsrtaNel�ed rt�sEerlak. . .A. PR T . .. . . . __. _ . ... . _._ ......... ... .................... ...................... ............................_...........,.............................................._..,........... : 1 : � , _ : ; ; : ':...................: : ; ' : . : i , _ ; ;.� ........................................... ........., . . ' . - � Archit ts � � ..... ...:....... ......................._..............._._.. ._...... , � :.... ., �,., � : � : ,}� ,. - : ; : � ���� E :......................................: ,.......,..........................................................................; � :...................................... , s03.la1.l666 F.s03.lE11�Z7 ....................................._: �...,,,,,,__....................,..,,.. ................,,,...................,; �...............,......................,., � _ � � ; Q?1d MAIN 8'iREET . IJN�f C101 � ' ` Y70.i� F��� � : , ; � : ( l............................� � i : �........... ................ � �; i � ^� i : �- ; ( .................... ;. ..,,,,, �; ` ......................� �; , (. ,..; € �.....................: �; ; .....................: �; � � Is � i................._... � ; , � : �; i �; ; ( ^; ; ; „ �...................... EXISTING SMOKE COMPARTMENT-CENTRAL ' � ������ ������ �"'''°R '�a,r'" • "ee°G"'�s, °°. � ' ,eeo ooveea�r�r. a�,rrEz 2 � , 375 SF , TYPE I CONSTRUCTION � � ` ''"'�1N0°D� CO °°�1° i; ' � � : : , ISSUEIREVISION DATE NO. - ....: � : �; TOV CODE REVIEW 1JUNE07 = i : ; , li ; ,...........,.._. ., .................................................................................................... ( i ; ASI # 1 13JUN07 ; °..::::::::::r.::::::�a-:::::::::c:::°:r.°:::G::°:::::::::::::::::::c::::::::r..:::::r:::r.::::°::r.:::::;;;,....................................................ry EXISTING SMOKE COMPARTMENT-WEST �_......... ; [.,, ,. � � � ; ; � ; �, .:........:::::-...�...;.....;,..;..;....;.;:::::;....,MV::;:::::::,�.;....;:.�:-:;.;::�:....;:::::,..,,....::::::.;...,::r:,:::::,�::::.;....................................., ............... ; 1 ' F `w� � jl >.��: . ; � i� . f .. : :�; : : ; �i .� . ............. r ; , ; ; ; :: y � , . ; ;: : ; ,tt�; : � : ; ; 1; , ..,...... :�. ;i ; ; �i:>�'�i i i i i i ; :i i : ..�. ; i i .;i; i i i� i i 19 , 126 SF , TYPE I CONSTRUCTION ' � ' " - , , . ,. , . ....; � . � .:":...' �� :::F�::::::::� . : ' 4 ' .. .r....✓. 'v • � ' � .. . .... . � : �.. . � il 1 . ' .... , r{ 'r � 1 �* ,. . : :::..:::..:::._: ': � ; :�, ; ; ; ...... ... ; i ,....., ..... ..... ...... ..... ...... ... , �....�.: � . ;: i�,,;4:..' ;; ;�'£;; �, , _ .v :....::::......:....:. � , � .. .. ..... ...... .� .... .........;:. �.,, ;���;, i�" ' f , .,... , ,...._ , , , r r<;., , �' ,, ................ ; ; ,.. � � ................ ,.::-::.; ... .....:-:; ^; , _ � ...� � ;..;; . ... , ,,y � : � RD= 1 ; ................................ ..,............................... ......................................................................,......................................................................... THI 2 �" ; ; , , .., ""� . ; ,., �: � ; . ..:...::........ . . . .: , _,_„w. ,....4........,. ;: ,. ..,-:�,..... ; ,.... �, .... �,.�,. ,�,...�,<. ,�................................................................................................. . rv. -.... ; ....,.,.; ;.:r...... ; , s� ,x ,.., .,. f. , i __...... �...........................,....._..........._.......................,,........................_......................................._.._..................__.............,.. ............z:::::::::::::::. 5, ,� ;� .. , ,Y�l., ; .� .......7 ,5,.�. :� � ,.°,�,, ; � ; f� : i �.'r.::::::::::::::::::-::::::rr:::: ;... ;......£.:....................:.................s.... ......,,;.............................r::.::.�...............,....«...................;;, r....... i . ... SECOND=43 ;-- ' -' ;; , „ ; .. i . ... . .. ,,,,,: : ;� �� ,....; i I ; IONAL � I ., ........................: ....; , , : . { .:: .... ... ,..; :: _., �,.. ............. ........... .. , ,: : ;.... :. ;......... ........ ..... .......... . . ......... , _ .,��..������ . : ;...� HEALTH ................. �: ; :: ;� ' �>:y � : : � : � ; : ; ; - ; �......., ........... ... ; . . i - , . - � . . , . r o . i;zi: :. �.�.,..... r� . . : . . : � . ; . —........... . ........ i; L j � � ;i `�,.5 , , S . F. ,,..:... . ,....,. ..:...,..... .., , . .................... . ......... ... T'r : : � f . , !i ... .... .. ..,.. .. .. f. � �I .......................::::::::::::: , . : : . . : : : � ..... ..,.. 696/2 , 1 ,5MRI. F. 40-3 .. ... � ,.. ,,. ............... ......... , , ... . , ��� . ;, , _ ;, :.. ; ,. .. ............�,�.,.......... . , . : : . , . •.. ±; .... ... �i: _ ' ._ . .. / 1 579/ . 18:.. ' ,:: ! , , '' ,�' ? ...,......_., ..,....., ,,..: i, r ru�,,,: � 4. ,,,. .. ;�;; . .. . ,; .. , , , ; ; , , _t L. : . .., ;I ; � !. +:; .... ,� � .:.... .: ., , ,, , % ..:. , ..z................ .......... ..X.� ° � . : ,,,,.,...... ......i£ , ,,,r. - : , :: �.i (i ii . . . � .............. y :...................:...................y: .. i :; :: ii i � :i . . ............_:s Yi , i?$,,;�;;�..� , . .. .. . .; .. . : ...... � .,..... , . .. .. . :. �: :: . . .... . : .. :: . .. � .. . , ii �, �„ ..i - i . . . .. „ . .; :: : ; si / ''...iii �. :: LAB � ., .. , ..... � �: ,. �_ .. . ... ss : . :: . .. . . ;: - . . .. ;; . :: :; : � :: ;............. , i:*., _ 1 715 S. F. :: . .,... .,4 , : ; , � � � • P : : �;;....... � s .. .. . �. .. .. a.,... 3 .... ............... ................. i : ......... :; :: : ; e .................... : i................................ �i �ii .. ii ii ii i,,.........J ii 1 ,71S11flt'k't8 . : , ; . ; � , ,. ................................ �, , Y _ :: , , �` ......::::::::......:......� n�:::: -: ................_.....;: ,. : : .. .r.... ...... . .... ....... R . . . .. r......................... �...n✓G :t .. . . .. �r......................:: . . : . :: jl :: 'v :I r.... ' : :) � :: 1 II ........ . . .: i . � . � � L . ........................ : ....�::::..i : . . ::^. � .. �... .� .. ' I t 1:..........1: �� I: I: :I II II �`..... � � W�.��r� �/'� \i . � " � ./. ..... 1::�:::::�.i. 7 ..... ..... ...... . ............ .............. _ � ................._::...,,. ,..,,.,.................,..,.,,;; ,- . ....,..........,... ' .:e . ,,.... .. , , _ i �',; ' : . .. ............................. . ,.,,,,,,, p , „ : ;,� o.Ti, 4.,. �y r I., , �, ..... . €,. :.. � r . ,._ , ; - , . ..... ;�, ' �� . , ,:. ' ' ,° - � - ii 'i i . : • . . . , � ' �� rr , �..� ............................ i � °D ADMISSIONS '� ;: �: � -�' ` �- ao -: ED ,, , � � ,.... 1 - 1 .. . . .. /; . ���: - - „ . -... 1 ; -- . . � - < .... . ; � ,. : ;. ,,... ;:: .. : ° :: , �r�u��r i�n�n�rr��iii�iii�r���n�n�rt�i� ui'ii�ii�n i�n�fii�ii� 9 � . . 9 ..... iMa� inr+� ...: ............................._...................................................................................................................................... .................._� .. � � �` � " ,. .. ::y ::.................. .. , :...... : �v..�: : :.. . .. f. . :,.., 4 ::x,� : �� .................... . . �; .� . ,.. . ..................�........ �'+CC;.'.L,,,. :1. ,: :.....,,,,,,............. .,............., . .. ......' ;'i � ❑I� . ......... . : � ' . � g �94 S.F. I:, •�,� �................:y.................:::::::;; �� �.�.�.sG�.�w��� ; r....... ............, ... . . . ....................;; � : -:; '•, 2 1 � S. F �, ` ,... �. ; . ` , ., , 70 SEJITS $94/i �9 I ° ,�,.,,, � � ` ' ,1 • ; ;�: ',, ,,.i"��"' ❑00000 ' ....., � ; ;.::; ; , ~ � , ; ' � . ...;, : ; . , 3OV�RFtO�' . ..... ,.�.... .... -� ,...... .... m ao LOBBY ,.. ` .. '""`�..... 366 S.F . ..... ... . : : ....2� 6�10Q� ,����............ PHARMACY ��:::::........ ,i , _ �, ;,. t - .. ....................... ...... ...........__.,....._......_� :... .... x, �I ,I „ j .. . � O . �� lluniivin � : ... .�............�.... r . � ... ..... ' . . [ � .... .......... ...... ��e/ � � ' a <vuum....y ... 1� M....... .. ......: ......F 7. ... li� .... . .. ....lva e...... ........................ .. ... . .. I...�...... . S� � - ' 1 413 3.F. � . ,: : A ,� , , .... . . ...... ......„ � , � 7i ;. . . . ..........................:../�'s......................... ........ .. �............................................i. . ... .......... ,�,...... .. .. .... ..�...z5 h/. ... / � r . .'i :; ,, . - ...x :......�...�. . :�w : .F 1 ......y, IYYYYI , ._. ,..` ��.� '' ,. � .'. .. .......................:y............ � , �.. ...n: ....... .. � ' ... .. ........... � , i � . . ....... .................................. .... .. .......... ' .......................:i............., ........ . . •� � .........................�............. ::.� :: ��� . .. T �«;:: . --�-�-�— : � . ,... STOR. � : r � 15 SEATS ..... ..... ,,,,,; ,,,,,,,.....A,�, .� ,,..................:..,,.............._,...:.,,.,... . ........_............ ......� ; � , � ; �., ;. y� ';�.� .�� , �, � ,...... . . . ........ ... . _ ........,........... � �...... :., 00❑00 ........ 0 � 0 0 ❑ �< ",•� i�'' ,' 18 M. �-�•- , ✓' 8 ° ; / a ,; ,. �.� ............ ........................................ ...... , / ::.........................: , , , 49 ; � , ° , ATRIUM -:::: ° � ' ' s -:...... ����.. < j> . � .... .. ... , ,.� . ... p . 'i.. . . , / ,.: ... . . . DING S�PPORT.... .. .. ... . ... . . .. . _�.....• , ,... ,, . . ........ �' v ///////////////// I :_:::, r,:. .. Ep ...... .... ..... ..... ..... ,,,. �� � n �.�,,, ,� ��v , .,...4 � ,sn s.F. �, ... ... , / , ... .; ,. .......... ...... , ... ................... ... . ....:.... ... .:;:.::. .............. ....� / ���•ym� ; 16 SEATS , .. 373 S . F. ;� �,�,.; 570 S.F. � ° �T /' � BUI b1I!wIG 70 SPPCIRT i • . � �,,.. �.... N� - , ,... �:.. o❑ 000 ❑ o ,; � 8 . _ ,-,. .. i ,, , ' ' , ,..;. �„�,���,� �: ,� � ,, L 2,470/30�9 , : . . ,,; ,, , , . . :,.,.,, / �� , 6 ' S F. !! � �.�. ,,., ,..; - , „ , ,.:,: OO� QD r:-;: .......... � — 3 . i ...W.., � ,..,... , y .-, pp _ ; ,� . , A , ;: - ,Y; 1 , � .................. ... ...... , �:.......:: , ,� :::::: ........ P � , ...........; .. ........... : ,. �. � . ...................................... .. u ; ............,.....................s r,............. " ::x : .............................. ,.................. / /' :: .. ., li . � q . .. .., f....... : .. .. �. zS ' e - � .: :: ' ' r... �(y , u ..> .. . . .. . SN ; .. �1........... � i (� ;: • \VY�T ' '.{i r � i . / �� . / iii r . :: . .. ......... .... .. . . . ........ ... ' ' i...................................... ' .,iY �...... F65 .,...,. �; ,.� .� / . , _ :: � , , , � w ,..... ; : ,.,. , _ ,.... ; ; ��,....; , .,.._�;: �...., i: , 270/30 9; ., t- 2 ...........................-.,......, k.. ` THIRD=48 , �>w�„ r; '' - / , IMAGING '; . _.,,:::: . _ .. , .:: ..,, 7 CORRIDOR 886SF�9 . . ........................ ........ . :: ; ;; _ , ,, %�::::;;;T; ; c:-:::%';:::::::: :::::::::::::::::-::::s:::::;;:::::,;:::::::::::::::::::-:r, % ; ❑00000❑ i: ;: *! 718 S. F. ;; .... , .. , ' ...........:..........:::....................:.... : . ..... . :;•;, a.::-;::�:::::::::::.;; f 12 �� .i i ; � SECOND=50 : oo a ::.. ;: -. ;� / �: ::::::::::::::.::::::: ::::::::::::�:�::�::::::.. ; " ; : l RECEPT'ION ......... .......... ...._................ ... �� 117 CONVER�3ENCE : o �;; -, ;; ,-,;; ;; pT ;; 4 71a�1oo=e ;; ;; IT FOR SHF � 2 : : ii �'�..... i3il ; .� .ti ii ; : i: Q�� : : i i ,. : : �.� ;.... . , , �:: ,. �. , :: � 1 ; 1 ,: < ,:::::::-�.::::::::-::::::::::.:::::::-: ..... . ..,.,, , : \ BASEMENT=67 1 S.F. ; oo a , .:; :::::::::::::::�; 1 240 S. F. ;: ;: ".,,` 9 S. F. 'I u STEApM�HJ..........................; ; f ; •�...�: , � .... 58 : ... ....... � ;.;. ' 391/1�Q■4 ao a • 1 .... � � , � ................................... ; : , ; : ��.. ... � �;. . ::: ,; ......................................< �2 : , ...., ; ;.... ; : , : . : ; - ; : , �.., � �,, 1 ,240V100�18 ...,, ;, , ,...; .......`�: 5a9/10�6 � cn I .. �i#.N� HAW�IN�............................... : ` <, 3�3 <; ; • ; ,.....................:.... . .....................................,,, , ..... y„ ., , ... ...,<: , ;::::> .:,,..,.. � : .,�: , ,,, . , : ' ; ....................................; : � ii.........li ; ���.�� ......................:: : . .. ........<: ,:,.......... .............. : .., . WAITING ; ..,:: ,......................,.... <:: �u ��... .. ...., . ....�a�m»,. .. 57s, F. : :� ., MEDIC�4L RECORDS ......., , ,: ,.. , v � �..., : � ......... ,„ , ....... ...........: :............. a �'a:::.-..:.: ;: .: � � , .. ... ..a::::::-......_,.......... .. ....... - ��:.... .... .. ��� 629 S . F. ;, .� , a�..�,�::::::..:::::..:::::.: u� : OFFIC�S.... �; , ....... , : : . . . .. ; : , : • , : :: ,; ,...... , , , : ' ............................................._ � �4 . ....................::::; _.. ; � ; r r, � n..................... .. : / : : ,',, � M :. , 4 . j..... , : : , . , 1 ZO 8EATS i= / •• ; . ; 993.:S-.F. , ` 87SF , ,. � ,,, , : ii i:.................... . � ._: i .i ...... .ry ii �i .J_�........�...� � ,y� p::::r:::�... .r %i , ....... ,; ,; , • � F ;; , %;1 ,487/300=5 � .. �'r... '. i A �� v �.. � � i : ? � j � �. .........,. , � . K...................:ai � 3 � r . i��. " � � l i....' r , i } , : . , R, �............................� � ,. ; s.,., �: . ` � ��� d-- fi ;; <;:;r,�:i : ? ;: : ;: i ii ..n i f: . 5 • .... ............................ _ �: i i f ' : : .................... s� a .'� , 3� :�.:.� ,- � , : _ . . ............:: ` .... . � .............. � ,. , ................ � .;: ; j . ......................... , , % ,. rc r :.........;: - ,; , 11 , .,,............... .._„x .................................:...................................-::� �fi::.-::::::::::::::, ; , , , ;; < F... . ,.,.... , , ,. , . . , , . � , ; � � ,. .. � : ... , : . 2 ;; ; � ... ., ; , , .. . I ........................... ': i=........ , , ., ,.. - , • ...... O ;!........ ! : .: : / ......:::::::.............. . : _ . .. , �- .. .. ,., � .., , ..... . . �.. 1 �, , ,. .,. � � . , . . .. , .. :: :... .......::::...�.,; .... ;.... :::......... ... ....,........... . .... , ;;;.......,,<:........; ; . -, : >, - ,.. ::: � .....Y::: / �� . ... � : , . . . . , ., . .., �_, :: .; -�:: : � .. ...... .... ........ .... .. e ,. .. � . � , :£ , .......... �� R . ., . , , ,. : ... . (; ... , . > , , :;...... ... ,..,� � ......., .............. ., , , ,... . . �. ; ,, , .. ,. ...............:::.:::::... , . . ..,., , _ ,.... ..........:::... � � , �., <. _ � .......::::............ ,�.�„�» i .....................,w ; . , .: / 1 :..... • _ � , �: 1 �,.- � .:.. , , , ;;..._ ,< „ 39 Z7 � ............................ . , � . � a..,m,;; ;; ;; , , ...........�.... .. ::. ,;... ;:r..., �Y ...................... � ............:. ,. :: n, , „ . ,.,..; �.. ; .. <x£':: , . , „ , . . ,. v::.. ., r... y , � . ...... ...r ..:: i: � • ; : : ;: .i......: �. �. . ::.................:o:..: . . . ;. .......... ....... .... .. .................... r,: , i� _ . .., . . ........................... �- ;;: . ., ,....., -... ii: n: ',,. i; ii y '.......�+x. ... . .., :.:................: `. � .. ,. � . .. i . _ .. . :: i.�'i t'. •.. � ..... :: . �' � .,....��..L............... , � ./ / .. . .. uf. .� .. .L . .Y . : jl ......... ...._: ' ........... .... ..1 n.......... '.`.{:...........� � � �. : .... ./ . — .. . . . . . . .: .. ,. ', .v ,. , ,� ......... .... .... .. %a ............ .. : ......e ........., �........................... ..............M � . , / ,. . . .::mr::::r...........:.�,,,.,.........,...,....r ; .... ..,ti;, ; j.. M al .. . e , . . ... � . . _ . � 6 < � , ,....;..,�;;,�;.,;;;;;;,�,,...., r; ;� - :�.... .,. .. ........ F = , ,... : ..... .......... � ... ,...., . , , . ;,.... _... ...., ... _ , � � , , �,m.. ., ; . ;; �, : . , ... .............. .... .. .._ , ; ,.., 1C . : : .. : :� . , . � ;; M:: ./ • � i . :r................................ ..........:.. Y.J: R . / �,, :: �, ; , � . ; ; : � . € �! i: � — . ..,, .. .............. ; .. , Z� ,,,,,,,;. , � .. . ................. ..,. , „ , ,. z. I ; ,,,,,, . , : .. ' , — � ,,.... ..,.;....., .;; �... .�.;: _.�<�::::..::: � v......................:. : ...... , ,....... � , w•, o .... " �I �I � ,...., . ..,. : : , •,... . ...,: --- ' . C RIDGiI� 220 S ; 3 - .. � , „ :. , ,::: ,.;;; ;:... ::.:.:; . , ,..: ............... . . :: , F , , ;; :: , ::: - .. �. :v ::;< ,, . ' ' ... �...;. : : :: . . .. ....;.;.:.;: :::.. ................. :............: , , ,; ,., . c� � ,... , , ................ ... c;;; ; , ,� <...., ,. ..... ... .......::::: ......:: . . �: , ::: :...: . ,.,,, ;�;.. . . . .....: enter �o . . . . % . . . . �� . . , � : . . . , . � ..:. . _� . � . � t . . , .... :.. :. IN-PATtENT "�� . 1 � . ydi::)%i�........ ' I�uu................. N............... nrv. � �qn.......... . , .. � r :y � ., ywm/ .., ..,,,.. . % , ... ,...... , ;,; , ...... , % �::sr••::::yqc......:::: .......... .... SPC ; .. : ,� . ��'�::�, ; ::-...:.:::::., - 15 , , ': ; ,., ,. PHARMACY , , ; �::::.:...................... . . . : ; . ..... . . .......................... ,, ' � , „ , ,,. . .............. . _�;.. _.. : . 882 S F ' , , � � . < ,w ; � :: 3� � ..... , . .... �::::::::::::r� ;. . �; ;..�.; � r . . , [ �, � � , . , o,....:.:.:.... F-:::�::::::::;:,:::::::::::::::< s:::;; ,.. .... �. ., . , '' 1 , . � ii:,�' k'..z : �r. � KY � � ... , e... _i . ; :. ..............i: �i/.. 3 � .. ,f,�...a: ��i�'^'+� .�.,9 815 S . F. :. ; �'t ...............: . . . . r.: : r £ ° 2 � ; �. /300- ........ , ;; ., � ,� ;,,, ,,..,,...,:;i , ,..� , 8 3; ::::. ;:::, ::::i ; •, � .._a: ;... .� , ..g'r : 4 ,... - ;; ::::� �>.:; ,. Y, ., �..,� . D. - � ,. ,.._,,, ;..::. ,, ;; , w ..::......,.�:::::- -- N `, �... , � ' ; : HOWARD HEAD ; ' � ,. ;; s . 15I100-9 �,J; ....... ; : ,, - ... ,,...................:..........:. ; �::::::::> y SHIPPING/ ,. � > 1 ,.� ; �; , , , , , ................ ..........:: . . . , � ... , :. ; ,.... ',.,..;:; } ;; :'-_::-:::::...:::::: '.,.,. -�;:;;;;;;;::::::;;,,,, �' 0� ,� > 3 ,320 S . F. �; :: ;r-' ..::.�.€ ,, DMIN. � ;;' 1 , . � ,. , , ...... , . ;� � ,... . . ............... , - ,, , ...........................:: 305 S.F. , ....................�;;;M .......... .... ..................... ......... ........ ,................ ......... ......................:.:. RECEIVING ; ; , , . ,, �. MRI ..................... _ , , �;. ............................:: .�................................................ .........._ :�::::::::::::::::::::::::::: , , �, S,32QI100�34 , , j .................................................... , , , ;�... 2 , y ; ,.,. ..... ;,,: '. 010 S.F. ° � 3 6 S .F . � ' ,. ;; .: :::::::, ;; � , . � ................................. ..... .. , , f , , . � i = <�.,,,,,,�i � ' : i � � ,.a::: ..........................r,: ; , ,,,, � ,. ..<� � ; � , , ;.........., ...::::::::::........:::::::....:: , ; `: , , �:... ........ ...... u.., ;.. .. , ;; � �..� G.�: ; � ; „ ,.......... , ; � �, ': . ,.... ;; :,�;,: ;i � y K:°�....: ,; � :: i: Zi u , `' i: � , y................... . . ,,,,,,,. - �;,.. 'u l "�. ' . :: .. � � Ij . ......d ...... .. .: : . :: ...� :: .y . , � :::iiu / �iy' .......:.� .........n : ; . ......:..:: . ; a THIRD�28 ::.:.> : ;; .. .... .. .. ....... .� ... . . .� ...................� : �� ...... .�..A.� .�//� . . .� Y.J. :: / .. R. n . . � I: �... . rY.,. ...Jj:% / /� .... l . . . ': .. . II b. I. . �� I i . . I. .R• ' .� � .....J: $....... . I . r� 4 „ :........�' �`s .,, . ....... „ q..... :; t::;; .. . .. .. . . .. .... .. . . . . , . ., r... :� .. � : ., . , . . ... - :: .. : ........... -.................................... .................... . �......::;��v7r.��xa,,::a:�' �:Y ,,.... ... �, . .. - .. .. . , . , ; , : . ... :;i�; ,� �,.,,.. _ .. . ,. .,.. ' � - , , .. : . .. .. : +. : , : . I tS. .. i ' ............ `.:s,.ii ;G n; .. .. .. , ii ii � ii � . , , , . ii '.�` .. °✓ � � .... � r �......v. Ye..............::r...... •°�j, � .. . .. .. , r � , '� ., ' £ : ,� : : � . :;;r. ..2�e;; ..� �5,.,,.., � .. : .. . . . : : ::, P... 4 :;;: y �.......... ..... � , , , ,.... .. �:.. _; . .. ,,,, ......._...............................:. ,..... r, ..,, , , •, �i ,....:: , ,. , ��;: �:: � � ; , - ± , - ....,, SECOND-49 ...... ; ................ , �;.. ........ . ...... . ,......, ,.... �����.�... , � , : ::::::. ....... .::...............:: . ,.,w ,-- ;; ; ; ":::: :� :-::�... ,, , ; COLORADO MOUNTAIN MEDICAL . ; -:::: � -•��: ......-:.. .:...... :......: ,,�; ; ,,:.> �: , FII'St FIOOr ,....... . .,...., � ,� ,_�.. �.. ; , „� , �: ; , „ , ., , , �;;: ,. _ ; ....K , ,.......... „ ;; ._.�::�,.�.. ,. , :::::::::::::::::::::.::::::::.: s,soo s. F. ;5.............Y......, ; , ;: ;; ;; ;: :: 3::::::: EXISTING SIVIOK NT EAST , f �, . , 8,800/100■38 THI�D�72 - ,��;; � , , . , � .................... ..... ....: ; _ �� � .... ..,.. .....: � 7 %' �x ��-. �yw;,: 14 , 513 SF , TYPE I CONSTRUCTION 5 .. ....4im% � �[ , , SE OWD-73 ��;;;;;;;���;�..�.;.����;,���;:;:�,15 ;�,���,��;;� ��,,, � � � . , � , �w :.. � � , ...... . .............................. ,.... ; . .. � , ., ............_............... : 140 CONVERGENCE � � , ,;.. . y� , �., . .. , S D N �< � BA E ENT=67 �.,, � , ' • . ° .... . .., � M TEADMAN HAWlaNS FO�N ATIO CARDIOPULMONARY ' aS' �(d �e��e� :.... ..... .... r ....... ,..... � ..: , ; . , , x : s :. <x; ; ;:... i 4 ,489 S. F. 4,489/1Q0=45 2 : 182 S . F. 2182l100--22 ..... ..... ..... �._„ : �.... . �� ••�., i:6 .: y : ....... '. ...... , vnrc,rron »xv/ y `•....,.. . .� . .. �( . , . , .. . , ' . . ' ' • %p /ih �/�^�Y✓� 5yp��' '.�/ 4� 'h {. 'YAi ./. ed � . . � j. � . y4yy 5 r@ . �� '91 :Y '{['^4i/ � � Y'/ ww. � na..� r �i a :w.. W.... � i': %.`.';L' t �. r i ='£ y. �" io . i y � � ..��. ';i .. ✓ H'' 'G ... ., , »w � il V v . � ,.....^;i . . .., .. ` y,pr�# a d r�qf � ' . , k � .., r 5 9'3 � °��; ' � � � �... ,, ,r ,,.,,. .� . "" �G4 - .� ' ......... ... ........................... ........ ._ ,.....,................. .5,r�h,........... ............... ...... ,,.. ............... ........................... .�.......................... .. .... b x.. 'l�D.iK 'nm.:� "vu�.. envu. �4J<t\z .yn^.! , .�i. �,. � . ..,.................................lH���65 ' ' ... . .... .....,p .;^ • '/ r V i � ,, u...... t �n...� �t� /�. .......iq . ,��i�� .� n............................................................................�......................................r� ........ ......., i � ' . . . ^u �'r.. '.� � . � ...• 5 .....� r � 'v . . : v i . ... . . . ` . � t v � � ,. '� . / 'y . . �. � ' � . � ... 1/ ��. ^ . '� ' .� � ' � � � '�. � / / : Y �� ' , i ^ . ..n..r.......i... ...... �. . ' � � . . r � l.t : i1 � • �. � i , f . . / i � �ik4 �, . . �....; ..... ..... .....i :.....i r � � � /�. / � ! q . Y -5/k'/FCbt�Alb / �. , . .,� - . � r, �� . . / � •, ...., .... �............ .�, , „ Mx '� ,..,;, ✓ ..;, ' , ��. ; , ii �, �., ; � ,.� , ' .. / � .... .................. , ....._.....,,,,..,, ,�.f,...nA,.,, , . ,... ....;, l ^ .�...,cn : � ,/.,,, v...,. � ,/ � , , / , i . •. r�, �a�/ ,a� � gi � .� .. * v " �F _ ..y,,,. .3✓,,.. ;.i'•e.i.:li�a5r,rvHn , .,.,,.,., ,..., .,.M......... , i - ,�a. ; .i,.,., , ,, , : - .i , ' �.. . � , � - / . ,a�y ' -Y . ti�u:lk: � .(„ � � ,..� ��: � .a. v....:.. w,za.5�n � ....... .......... ........... ........ ,r�.,,,,... / .i . ' R , ' v v� .,,..., .. ..:;'�, .. , .... .,,,.,.,.,...... �. ,..,. �... .n ,� . . . ......�. . , .t.. ..."N;°�� ::. : .... . . . . �.y ' •'//.. ' / ,. .. �. .i / � � <^r/�Yr . „�/� ..�� �iy < � !/i. A'a.,..;^ �!/y� oa... . YtLi.:. /%.cy. ..,. . • / >..•/��p .� . ... � . . . . � � .� � . // it , , /�.., / / , : , , �. � •• ��; �, / .': ��'.,,. / � � / 'A. �, n �t .y' k ,t , - � 181 W Meadow Drne , , , � , ,,. ,, . , , �: ,,, �y�-�� � . .. .. . , , . . , : � � ' s. . ..: / , , ,, �� , ' � � i �, - „ / /, � ' i -X :' g�� � � � � • ; , �� r.......... ... � .. .. .... , . . . , , , ..,. ,. '. ' i / � ° `'�.�;�., . .. ,/ / ; . .,.. .. . ................. .........,..,,,,,..................,,...., ....... ...,,,.. ............,,,, � . , . , . . .. .' , , . � if ' ........ ,.. ... . ..,...�.. � . .. . . ., i , .. ... ,...,.. .. � '. „ . , .,.... ., /'� I � . . .. ..._.. .. . .. ....... , . . Ve COlOredO . . � ;� ��. . ; �.� •.... .• . •.. ...�:._.. ........, •.., : �..:....� ....................................._.: " ' � � // u��i��� . � � Y • . .. . .. . . . ... . . . ... . . ..... � .. � � • ..... . .. .. ... .. .. . ,. �. , �� .. . ' `......�"'. ��i ... �. Y��'RHb<N ,.... .........................................:. ' ``. ,. .. .... SY.,�y.,L...,,.. .. .. . . , . . ' . .... . ,, � ....... .... . . .. . ...�. .. ... ................... ........ ,.,. ... ....................,,,_,,,.............. .,.,,,.,,,,,,.._......., ,,...,,,,.. . . , ......... . ....... .. ... . 81657 . .. .. ............ . . „ ...... ,.. . . .... �:.:..:... .......................... .........:.:....:...... .:. ` . . .. . � ................. .. ..... ,. . ,... ...... .... ....... .... ` . .. ..........................._... � , ............. .... . .........�....... .. .. ... ...............� ....... , �.. .......... ................................ .......................................................... ... ............ ... .......... .............. ............ . ........................... . :,... ..... ... .............. ........._. . � ���:�� �....... .. ........................ �.�. ..�. ......... .. ............. .. ... �.��, �.�� �. .� PARTITION TYPE LEGEND OCCUPANCY LEGEND FIRE RESISTIVE REQUIREMENTS: . , , .... ........ . . . .... . CONSTRUCTION RATING �,��ys;�^� ��������,,� �����yC�, j8'-0" CORRIDOR WIDTH STRUCTURAL FRAME 3 HR 1 HR FIRE / (GURNEY EGRESS) ( INCLUDING COLUMNS , GIRDER $ , • AND TRUSSES ) / BEARING WALLS LIFE SAFETY PLAN EXTERIOR 3 HR •• •��-��-��-��-��-��-��-��• 2 HR FIRE wTER� oR 3 HR OCCUPANCY 8� SEPARATIONS NONBEARING WALLS AND PARTITIONS � 1 � � 11 � 2 HR FiREISMOKE BARRIER NOTE: GROUP B OCCUPANCY EXTERIOR 0 DATE 2 APRIL 2007 (UNLESS NOTED OTHERWISE) INTERIOR O DRAWN BY co FLOOR CONSTRUCTION 2 HR (INCLUDING SUPPORTING BEAMS AND JOISTS) cHK' � BY sN ROOF CONSTRUCTION 1 . 5 HR MODEL FILE A1 - 1fpl .dwg ( INCLUDING SUPPORTING BEAMS AND JOISTS ) COPYRIGHT 20D7 BY DAVIS PARTNERSHIP P.C., ,,�cr,rr�c,s HAF-T SHEEf NUMBER: , LIFE SAFETY PLAN ( INCLUDING ELEVATOR) � AR 1 ■ � EXfT STAIR ENCLOSURES 2 HR R1 . 1 / 16 '� = 1 � - 0 „ 0 8 ' 16 ' D.P.A. PRWECT # 06938.00 . . . ............................._._____—........__....__..........--- .. ...�_. , ..................... �.; ,.................................___...._...._...,........................_____..........� : _ ; i........__.. . . � 3 : i i '. i : i i 5...................J � i 1 i . ' � ......................: : i j i i € i o ' t: E i....................................................... � � '::-.-::::::::.::::: �.._......_.........................................4 �,, . - � Archit ts _ ....,.,. �., .� �.,�,�. .,::� �: , � ; : � : ; � . . :..................................................................................: ; : � �� :.......... . .... ..... .............. : ......................................... a�'.ee�F r�°° � ......................................a ,....................................... ;......._._..._......................: : - ana ww a�r�r . uwrc�o+ € ' �.eoeo F.�ro�'�DO.ame.eos��°� i ; :::::::::::::::::::....:. 1 : i� ; ; � ; �■; - ' �.......... E ._............... ii � ; i..........................3 i � i Y..: ; i � � ....,�,.........W ? � [ �: i �i i �i .........._......... �i ; i - ii � ii ii EXISTING SMOKE COMPARTMENT-CENTRAL ; ;;;;;:: :: . �� � a �,� � 21 ,375 SF, TYPE I CONSTRUCTION �' I ; ,ae000v�ea�r, eu�z 1; w�w000. co eox�e _ � : ; ; as occuPUrrs ; ...::::::: ' 188UEIREVISION DATE NO. REQUIRED ECRESS WIDTN�IB' i E : PROVIDED WIDTFi-�o' � TOV CODE REVIEW 1JUNE07 EXIT DISCHARGE � ASI 1 13JUN07 .................. .. ...................,.;..................................................................................................;.......................,................................. i # ,..,.._ , ...... ............. .................... ..........;;................................................. ................................................., � � ; , ; ...... „ ..................:�....................v.,. ,_�.�............(.s�',. . ;"(...................ibe...,....t.;.,..;....;;:::::;..y..;...,.,::::;,�:.....,:::;,:•��::�........:::r;.. .....,::::;... ,,y..::::;�"n::c::;............................ _.. ; , ; i i................. EXISTING SMOKE COMPARTMENT WEST , , � , � ; ---� .......,, , ° �'� ��� 1.:; ;�::::�.:::.::,- ` �..... ���� �� f i: ; � '�� ` : �!. �� j '� � � 19, 126 SF, TYPE I CONSTRUCTION �• ���P� ' ; . REOUIRED EGRE55 WIDTN�12.8' ; i � �� '' ' ` ; � ' - � i . i i �- :,. -: . .., � : ( ! . . . : ..:..............: , , . . ; ..........._..... ,,... ...i ; > i i : t 1 PROVIDED WIDTN.41 ' i I � E c...� �. ; ...._iw�:...:::...._.......�.., ........ ... .. ��M1,:;.. ..:�... ..... ...... ...... ...... ... ,� . ., , . �..... .. . j 'Y.4'>.:?; >.. . �L: : EXIT DISCHARGE ' '� � �:: �-�, � ; :: I ...::: : ` � . ....;:: . ; , . . , . ,.. . ,.....: , . :; ;;. `��;; , ; ::��., ,:::::::::::::::. ,.. i, :�. :::;.. � .. .., ,. , ..... . >.. . ... ,.: :; z .. : : .... ..........: . , ,�, . : : 3 , � ................. .... ........................... ......................... ..... ...................... ' � vY2' .k.^.. . . . . : � L........... :: . � . .......... ........, ................... .. ............................... ........................................ ..... � „ ' . . i i i : , � . . ....... � � � . f'....,.... .�.......................................................................................................... . .. � , s.. rrR .... : : . ., ., . �. �.. : . . (,_ ...... � ......... . ............ ..................... . .............. ........... ... .. ........... v� , �� .....,. ... . ( , K � .....,,,,,,....,..._.__........I .....,,,.,,..,,,,.....,,,,,,..._..................._...,...._,....,,,,,,.,,,.,.,,,,,,,,,,,,,,......._..........,._._....,........,,,,,.,.—_.._...,.,.,, . . �"�{.�<.n. ...... �.... . ....µ;..r.... ....w.... .....'.... . ...a:...........:::. I < ; i� .... � s<�£ � #. i r.....".. ............... ; . : �• ..... ii ii . "3� ni: `�` .. .......... '..� ._ � : I ; i:'' E ;: °;:~�'� � ......, f � ; . �I ........:- , � :.., _ `"ti i,., :................................................: � ........1 : i ....... ::........ :: € ...... ...., ..,. ' V {�I II�II . � ; .,.. ; � i,.. ' � �� _ . � ..__.......... : : : : . ; :r. , , � r::r ,�;.;, �� �, ++o _`ti,,, ........................:::•i �:::. , ..._... � ..r; ; . . . - ,. . : . . .� � . . � . _ ,,,,,,,,,,,,,,,,_,..... : , ,� , ,,_:.:. _:.x... � . . . :. � ' ` � • .. . . .... . : :: : . .... .. . , . � :; , ; � . .;......;_,. ..�. .a . , � ............. ........ , ( . . . . . :t::::::::::::........_.__..._.. .... _ ... � t ... ' . . : � � : � . . , . ,,....., ......... ' y:. .................� ,..,,_.. � ��y, �� ... ' .i ::: . . . . . : � : .. ti� ,.E. . � i i i � ( i i i .............� � �� ...7... 5;' �';y 3 i . li � — . , �� : ....ii i ' : . . . ; i : : : � ; � �......y, j; �.... , w�'�,,.�i . ..,s ts�, i ..�. i: : ....� _ � ' � � .. .......... .. •� y,�, . . � 6................3 �; ;; ...a :;::a:.::::: .i �i ; E u : . �. , . . , ..., . . : � . � . : ... v... ... i::.:z.........._. . . . . . . ' . . . • , � .........................: f..H 5 �✓..',��, ° , � f�.�.�............ .. : ii L i•� i:r�-.::i � r......................................... .. E :.� :3 .. ;r.. J ......k j , E i ;i�'„�„ ' i i ! ii �'; i ii ii i Y^""1.... �\ i ...... ,'�y...i Y i v °. ,.. L.i ; 3 . i f ii � : ; ii i; �i ii ....... _ u i j ` '�. C Ei , ; .. . :: ii :: : i �! ........ /��� ��.; . { ,.� ,.E:i � — _ , ; . : . ::..............r ...� . :: : :: • :: : � ;i... _ . ; :r... .... . .:.. . .. ii . .. .. . � . � ............... .. . .. i i ; € .. :;....... �� :: : .. .c::: " �i I� - rWY.�I . . .... ...... ii Yy� .. � : E .. ............................ .^,. ii � : !i ii i::p:::,,::i : � _._............. ^ . . .... ............. . : � :: .,,........,... :: _ �....::::::::::::::...........e [: _ ,i . : . : , �. :: ii ii , t "'"�,=:,� : ii . . yi. ,. .. ; ............. � ~,..y .... . � .. " fifYYfYYW.11Y1Y , : ii , 1............................. . — :: , . , ..................... ...... .......................,: � �,......:: . ........................... ,.......u.... _..... .. � , �� .� ........................:: .; :, ,. ., :.... :; .............. ..... , ;> :::: `.......„ �, ,a , � � .._. ...y . i / � � ; . ::.........::: ., :: _ ' � �..�. 262' , . ........... .: Ei ., .. ,,......,.,.. . : � . !i :: :: ....... ......__. . . .. .... � �v ...,.....,., .................... ... � .......... �� i n i�;q;:;y.....ii,.,,.z:: i f .. `A . . . .............................. :: �: . . I �v... ,,,,....... ., u:: :i,� . , iJ i ;......0 ., .. ° ., ................................:+ ; . .: .. .. :i .......:..........:.. .. � � i i . ... . : r. ' :: :: f: i % ' �'�,.. ii ii ii �/ f,:i �'� . � ..3�. i .p � � E l� " ;;s.. / ., , � /. ." � '� . . `1 . �.: i<. � � i �, \ ' :. ; y � i: , : ; :: ' .m.�;,...�:_:::::... ,-.�: f�; • ;� `: >,... ` ...,..... ... , . .. �.: �:: :. . .. �: ,r : :: .. :...................................................................:: :....., : ': i-.... � „ _ ,, :...; % . , . ..._ ...., .;; ... ..;;... :::................::::: : ..... �...,. �� ' � .,... ............. . ' . .....,.... : ............ . :�'� �„ ,.. , ; ; , i . , .,, . : .. ; ; - ;� ., , ,.....: , i n�i ii�n�n�rr�rtiu�uirr�n�n�u�rr�n�i n�rriU�ni�n i�n�u�u �, ±E.. :�................. . - ,..... i�,� : & .,.,..............................,........,,,,,,,.........,....................._.._.............,,.,..,,.....,,,,,.,............_......._...,........_,_ ................... ......_..... . . . .. � ;r,iC::::;....r �;, : . :!: ' t . o : :: , : :: ; iv'-, (i :� :..... ; `r.,,,., ff i ��� ....,p,.;... ` . : . y. ..................ir..... ........................r :. -t�................ .......................... l............,. ........... , ........................,.,,, � ......< 4....., rF .,.....,, �� : ......_............_._._.............................:.: : , :g w n � : "�kX �o i . PROVIDED W �� . . . . , . , . , .� � � . 1 ,....a � �, � :,�, , � : ...�w �,.��... , �,•, � ;� . ,,._ , es ., ...... � :; ; :: ::; 1 . -; � .......... ....... ��H- �; Yr � �. , , . , ; ...' ::::: : .) „ :..... 'YW'�. . , i' ° ; ' �. '+, ` ...., 3i : '� ' ., r.............. ..:: .,...., n.,i� M , � �� ,....... j . ......................................... .... ': ; ; b......., j : ; ' : : , H ,. ,. ,,,,�,,,,,,.,....,..,.<.., . ......................_......._....�, - , — ............__. . . , � ... .......... ...: ._ , � � ; ; ' ISTING ORIZONT < � ..._� : ;.... - .. , ,, ; :: , ;i...; . �� . . .... : �. � . ;I: �; ., . .,�,......................,....�5........................ ,............ a�...........................................,:............. ................��........�..,......�...,...�,v........ „ ,.....�.........................� �....... , .. �. .. ..... .i . ... ........ / ;k .r. ...... C i . .. :::.........................t:...........,. . � n.r ,,,,��yN�irr� .............:...................... . . ... .....:............. .................. „�..... : ........_........._.c..........._. �\, ii /�,1 IJ .. .... ,��.........___.�:;;:;, . PROVIDED WID'fH.82 �d�,. .. . . . ............................ ' ,'.. EXIT DISCHARGE ..............�............�...... .. ; � , , , , s._..,,�.., . ... .....� ; _ � i : . . �.. :. ....... . __ . , / � ��;;:., ,f. r:::::.. w t.....r ........ .. : �. I : f y 1 � � �� � 980CCUPANfS. RFAUIREDWIDTH.t9.2'(CWEMRAL) .f„ fs��.y . �ss:::,. .;:::>.....:::::::::::-:--:-::.—:::,`" . . . : � _..,., __........_:s;�� �yi'" y���"• rCv(.��^ � .,.!::� 4 9 O C C U P A N T S . � � . i 195 , i ................................................ .................................. ..........:....... : / i i 331 ' f ; `b �, .. ,� i REOUIRED EGRESS WIDTH�9.B' � < � .....� t� �� / ., ........................................................................................ � : � , PROVIDED WID7N�71 ' ......, ,. .... ,...... �e . .,,,,, . i f�" .:°i f:;:::� :::: ' � ... ....... , . . ......:t 's�::�::.... 5 . ri.�'' ::t;ii :p;��r t..... ..........., ii li .... ............. ,.� / ....; �... , .. .,. ..r :: . . . � . . � " � y .... . ,,..... .... ...... ..... .... zN.. n�u.... ...............................� t....-.--. . ..... ....................... — ....., ;i � ' ,....., a sxm-,..,r ::..%.. ........ ...... .......... ........................ .... .... � i � . $ � PRWIDED � � ' � ' � �i �' .,,, „ „ iiiii : i .. i . . ,. . , i : . . . : : . . . . .. : . 3 � � ...................... ....... ........, .,....,... .,.............. ............ . / � WIDTH.73 --�iiiv.ii�. ; ' /. ........ - ,........... .... ;c.,. ..; ..., .: ,.,s' i j j ....... ,� � r., : : , ; ; : c"`:. '�;'i . ;: � • .. � : > . � : � �; : ? €J ... _ ,.. t:.... ... .. .... ...... <"' ....... ... . � .. .:.. . .. . ... ... ..... ,. ............ ✓ ..:. �w�niww�� nwwu i� :.;.° /. ; : � J 3� ' - ..... .,� ^ ' ;; : . I!!!}.� "' • :. .. . ., u .N,.?w�em�'saw.,..i ,� : ;;••� .r.,, z:_,• uwi;: ...... ..y, ; r , , ,...;, r_ ' / ................... � -. . . i,; ;€= � ,. ' .... ; . !: i: ,. ; 3 � � , ;: i ' ": ; ( i �:....._:: ,... . �i u , ; ;; , . , .................. / . ....� ..., . ; : . ,. � ::�... ......................._.......... :...... „ i .. : :: : .., . : :............................................................ .n............ ; ;.. ............... ....... � �rrYwir� H ��. . .. ........................................ L::-:::::::::::1 ;� ..,.F:::�' i , FJF17 DISCHARGE � ; .. ., ,.. . .� _ ... . ! .R � . , .. . _ _ .:, ' ::::, . �.....,, .... ' BS OCCUPANfS � � � - . .. :......, ii ^•. d , : ; .� _ t::::it �..,, i J . 3 , ; ; s . , , � -- ..... S NG ORIZONTAL EXIT 799.5' ..........._.............:..'"-:i �: ; REAUIRED EGRE55 WID7H�13' :f",,. � ......^ ...............,,. + ,•• ` ... f 117 OCCUPMRS .. � :: i. ................. .':' .............,, ,,.. ............%:z:•r ii ...........,::.... - � w.. � ' 1 : :..,......_.. .�..... .........; ..............._.......,........, . _................... , ., �� PROVIDED WIDTH�42 > •••••"�,••••••• ,: � i••, • 1r. � ' R REOUIRED EGRESS WIDTH�23.4' '" i � "��.. , ' S5 OCCUPANfS, REOUIRED WIDTH�11 ' CENTRAL 29 OCCUPMlfS, REOUIRED WID �S.B' �������� ��� ` i PROVIDED WIDTH�45. . : :; n. � li � . � , . .....:5:::•c.c........�...�........................ ��T� 3 ' � PROVIDED WIDTN�39' i i iE ii� li :: .............. ................. ' ....................................... 6::r•�:::::::::r.::::°+; „ '7. i !:-, i .," i iE ;i ' � li ii •��`... i i � ./ . . 3, ,/ ��.. i :: ^. : � ::: i :;p ,.. , . ; '�.::. i . ........................................... . .......... j i .. ,. � , ' i ........................ .......... . 7 . 1 / �'. li � I:u..............�i �f i(i � �! _ !! f � M..n„� :: i i � � i �..`:C:::.:IY::.::::::°//././L::::::::::C:::::.:�lC.S �IL:2...'.:::T::.°LT//://///:L::.°:::'Y ............... j ; EXIT DISCHARGE ::::::::::::���... H::, %................. � ,,. ,; ,,. ..:. � w ;; ................................::::�:� � i ; � : ,, ::::,. I , : , � �.... ......,. . � �4y � : . ................................. , �, �:. , ,, � ,� �:::-:.:.��; : :. ; � `• :; ,...< : '; , r` , , ; ; , ,.....................:.... .................................................... .. ... .... ... „ ... ., ...,,. . ;;; ,,,, � �a� ,,�� �...�..... , .. ...::: , „ ., �, ; f ... .... ...... ... . :: ....., „ ... , .......................... . . ... �: .......... .....ir.:.....r.� . ., ;;; ' f • u�iu � � ; , ,:: ............................ E .. , .�:: • . , , ,....... ... _.;' : i ..., ... , .. .. ...a�: i!!!nD _ JJJJJJAIJJ . . ..............._.,.. ,. - :...� , . ...v `0., : ....� � ..... ; ........................, � , : ��° :: : ;; .�:� � ::g,.•., . ., ....... a.::::::r:;:/ : � ; �::::::::::.; ., i ; ............ „ ., ...,i .. ...; � :...Yr.iiiii's'szzL�L[�::'f , . , , ^ . �". � :: :; �/ : � , ' ::f Y : : : : � � �................... � ` ; . : ; , v . � ........... �� ; ( ; � i � '� i ii E� � . . ....... ii i �'�. : ,. i .j....................................................... ::..3, ; :::;ti..., i� z:::.•-,. i � i i i.: .......,_,,.,,,,... . . � �. , n : i� � ii ;�....:.:............. _ ../':c., _ 1.... ?i : � i � ,,,.n�,. ' ii ij : i i3 ::::ii f i : ; i ! .j � i ; .( 1.....'. ��.... . .............. — ./ — ;'.i � P:)i 5:::::....... i , ii y , . . ° , i iG�' ii , , , . � .........ii t . /' 1 i% i .•• ii ............ . . . 3. . . . : . , . . . . €i �I .,; : : .i ••. `�� ;; i.:.i , ,' , , f � u i , . ,;, i ........_.,.........z . , �j . �� . � , r . :� U.. � :........................... ; .�" , ii �„3. ...294 3.....�i .. ... ?� �� ?i ,��� ii �...J, i y ,�:,a: 4 '! y r . . . . ............................�� '{ i: . � I i : :. ...............✓ J p: ..... . . ..................... , . 1 .. +,��i' {i :: : i.. ...Ji.......................................................� .. , . , �: � � , ..................: . , ,� , rc .r � ...,...............,....,,. - $i ...... .................................................................................. , , , .. / ` : : •,., i i ; ��� ��rn�i�wwi , . Y......_.;: : f ................�:./ � • � ii .f`.::: ' t�i i; i�. : i i/ fi 't it . .., . .. s.... �, � ii ....i x::E;::: ..... ; � : ,. ........ � :: ...e . . ,, � i, ....... . . � : �, i � � � ..� . � ... . + ii : r_�.__......4'�^..'r ........ ,/ , t .. ... . , , . .,q , , _. . ,,, i ._ . .., it � . / .i Y .. : . (::�-;:.:::-... `�......... ✓ ��� i : , . .._ , , , ;>........ . . �... ..................... . �. . .. / . .� Ili .. i ....... 5: ...� . . . � A. / � f ....:...... . . 1 . %y . r1 .......w....... 4 . ..n �......? .I�i. rY� ...�4 ..� wxxixw// II � ..... ..... �. u � � .......... \ . . A.. : . . . Yr....... . �. :�y... ' 0 ' '� '... I: %� • f I � ...� . : I . � P.u.. : ...�/ 'lr....Y.C�dF.� �41 : { / " � •/�, . ..... :: i I � p r.. : '....... ............................. .......... t � : • . . : / ....� � .......... ............ �'1 : { ' j �. ... .... .. Y.. I �� �"' ' v . . � �� > ' . .... .. • r � f ♦ 1 . : / .. I i , i � . . ' • .... �...........il . ....� r . . . . ... i:l ....,y � �7 � ... . r :: /� �� fl . .'/� ......... .. :: .. : i '/. ........ ., . , f ....... �. ... .......� L : k .........M f .. .� "M I: • • I � i1111�f11111110�� :; g rv.... II � � ' � 4f2 jtl: .. �� ': . . : . .............A:L.AW.:::Lr � n . � �.iiiisii 1 : . . � � ............ � . .. . � : . : , . . . � I...........................:. .. .....� .� i � ��......... ....<I : �...t +•,•,t I r ............................ :I ::� � . �y.�: "i I . :).. /��j. ��j.... � : t .. ... . ....:: :: I: • . , : . .j:G'.. �i:::r................................:.: , . . . . .. . .,.... . .. � .t... ..,,... .� r � .......... .........._. ....., ii / ;i �. ....,.... ...... i; 82 , �............ . ............Ji ;.... ., , , . ;: F... �; y / � L � ................ ., iii `. ii r.r , , � . � . . � ......... ., r.. . „ ; , ; . ; ,w,,,,e : : ....................5...*.:::::! C.: r. M:::::::ii . .. .......... ,.,.... ,, k°:C'Y; f..;::::::;P'r:L;;:;::�•. _....__.......... ! ; i : � 734 .� _it •.� /�: (_ � :: s,..� ;; ,�,� ........... z � - :::::::::........ii ;;.�, __ ,' � . ,� . ; �i . .. ' . j: 1: {: {: {: . � q................� ........ � � ...1 { : 5 � ({ �� �' :"wi:j : ..... 1 . ::........ �..__M................. . .� . , : . ......... . .. . . ; _., . .. .. :: , t :...... . , , s3. �... ; �,. al } . , .�.....��.�..�. _. : � . , . , . . .. ....G.. .. ........ , ;r.. . : , ;: �3.. ; ,.., � � � : � : .�..:::: , - ,..,, ..........._.... µ... ....,...::.�:..::::.::::::::: :': �; � _; : i — f x <�; :: �,� �e; _ , . ... / . ,. �...... ....,-............- — , . . ............ . ._�.,. , . . P�::..... ,. , ,....... ... . , ...... �.� ::<:` . , � ... ,,� � , , . f ;! . ...�1; .:�::::`� � � ,..:� / .............. ...... ��,� n . . �I � �t � 11 ;:... � �.,..� ;; ;:,�; , „t .... > ,..K .; :., . ,..: <... .. . � �:::::: , .. ........... i �£ . :. , , : ; � .. . ;: F(�((�"N ., :. , :: . . . . .; .. w.... ., r.cn::::::.......:z .. ar • ! , , o . i : ;; . .. / :: / :: : . : : 3„ M i �k' vl.,,,,:, i : :i � ' •;"'+, �r..... 4:::i . / fE �i : , , , �:: �...; ;..1 � ,�, , ; :: .::::::::::::::::::<: `�, : ` 1;�... : : ..... : . . , „ ; ............. ..: :...... . : : : � : : .:::::::::. �� , . . .: � 4 . , :. � ._� . 3 ; .;f :. :: , .. . : ;:::.._;,�::::..... Center . : .... � � .. . ., . .. ... , . : : . . , ; ..... sax� ?; �;;:„;,........ . ;.... ... . „ , � � , � , i�� . �, , , .,...., � , , , : :: ;� � '%� ............ ...... .. . .. : ................... .....1 „ ...� �. �.:::�<.. . .............. ,� s :: � ;; , ,.... .. ;, . ........,,. . n ... :: � ::::....,.; ,.., ..., ............................................ :.. .......:::.:............. � � .. ... . ,. ............ -:,r�c�.. " :ec:,... '. , :n. . :., . : :. . .. i �rr� I� , �weni � " :::::::a::r� . .............. ......5`".l#r.::c-:^r.xaaacc:: ::::Y'.e/G::acr.:r.::1 Ei . �i , i , .. ..... .:xy . . �d "' � � � .,. , . ...... ...5 x..... ;� ':::::: ' y' ....�����` ,...,�., � . ...,. , : . , • { f "�� iz:..........t i ' y� ' . ' I III � i.. �� / ��� ...�y......� � � i �� _ •. i : f r I 1 :.rl L. �I :Ib✓ I � '. :../ � II £ � �: ! ...�r .-........ S": ..................... . .n........., v ': :: i : .. f ' � i . 1 .. ., � ..✓/ r .. : f.. ,�. . ... / I: "'n� i : ::: .::['� � ) . I r . �....�l.T...� Nn.. It � i N'^^'p : :: '.. (j444 i: I r,.i/ �'; ' .� II : { � l : . � .� ...... ' ° i : II �, "�� r ' j p' � . . �.� i .........1 :: 11 : I �..., t f : .. 1 x • ~ : ". � '. : : t :: „ u.: � ........� ...� : f: i: : i... `' /" � � .. Ktl«<!.......................I: � ........ � . . . � .Y. j :i `` ::.j : f v . . : 5........n .'.. r..........................:p . .n � :I : :: :[ :i . f lc.. ..i�: n , . ............ i, ; •,� � �..._..,�._...:::;,/� ....,... .. _ „ �, �. ti. , i : : .... :; (- .. � - .. .. .... ...... . . . � :r,,;..�,.c:..::;v„ ; y, � :� i i' i: ., .� . ., . . .. .... .. ; .. , ., i�.. .. .. .Ji . . . i . �i _.t...:..:..r. .... �'. .: ;: :: ,... +. .. ii : . .. , .. . .. .,,.: ^ , i....y� . . � � : Y � ::...............�, r . . �. . . ................. � :: ��............... .__..........: .. . , ..... , "' � . . ..... ................... � � , .... ............... ............. .......................... ...............................:.:. � , .............. ._a . ii .../,4.m ii �i ��........_.....................,,,.,..... ( � f � I� ::....:::::::::::::::::6::::Y,� ...............�.......�.........................................�.... : ..::::::::::::::::::::::::::....: :... . jn.{ � f � , ';_. ,...j , ...................................... „ ..................... , �� ` . : a::,... " E ..... 't y.,,/ i� ............ .. .................. .. t ' '- � ; .. .......... ,, ii : ' ,,ii::: " . ,........... , � � .. , ..... .. 1 �. '.. ; ;: _: ; = s,,,,,,,, ; j .,, .. i , � �.. , ,.... ° � ............: m,,,.................... � ... ... ...... °: <.. .. , � >... ......................... , u...,, � � � . . ,. C.� i %1"4: i' . � . I .. .. ..r. .. . . : .......,, , , , ii �, '+, %. . . . / ...... . j, . ii �� �,..,V, i /'� i �::A x:�; , , � .... ' . i i; ii ii � ; i i �i� �.. ... , ::...: p{'. y .. "_ _ �; , , :s................... : � ii . .... i ..... ; • o • f: ii �,.r. .....n � ; : /.... M°� .. , .. . ................... .....: .. ..: � � � � ;i..:........ ...r.............._!i , "MYi. 81�-� � � 'Y ........ .... .......� . . .... ...[°% : ivi % i / . .. , . . e. :: . II f ............ %� , . ., :. . . . ,: :: , �.. � i , o: �z ii , . '�",' .. : r......... . ...i.......k..� . ii ,�..._..d.. , :i ii : : : :: . .. . . . . ,. c . . , Ei ii :•�s n — ...�. ................ . _ _ �................ . l.. ,�.. ... .......... . .. .....: . ................... . .. � .......... . .. „ . . �. i . _ .. .. . . . .. .. . . :; ... , s.,��,. . : � �: : : r„ u.� E .....::^ . . ( � : ;�.... 5 L�,. , c..., r. ...........:r .; ,s �,,,�5•::�. ,� ..... . � - ...., ' . . . _ .. .. . . . .. . � rR,.. , : .................. ....�;. : ... r. ... ... "'ij;; .. .. ,;. .;�%'; .. .. . . . .. .. ; ............ � . . . . .. ., . i : E ; .. . .. r. . .. . . . .. ii :r... � . ..... �.. ,R . . ..� , .. :: u� .: � . ... .�.........................W . �. � . . . . .. ....�:::.. . . . . .. :: : . . . .. ...._: :; e. . . ; i ;; � i : . .. .. . . . ... . .. . . . . . .. ..... . ^ �y � :, .... . . � . . . �: � r. : ..... : � ........... ........................ 181 . . . . ,;,,;;;i� ,........ . ... ....�.......�... ................ ......., ..... ... . . . .. ......... .. . . . . . � . ,....... : L..._i � .... . . ...... ..... '�'� �� � : .._; .. ,..... ..... ....... , .. ........ ; :. ,, .... •. :� , ... . .....:::x ...... . ..:: ........ , .. ii ii ':'.::::. .... . . ' '_ �.� � � : ! iE �..� ii .:� �, ...::: y::::.. ,..., i �... .. . � .. � Fi FI r ,..�, . ........... . ..... ::::::: .......... � ._. rst o0 . ...... ,..... . � ,�... E ,, � � , ..„ _ , ... , :. ; .... � .......... _:::: ��..`�; i: i';:;:> . �f._; ...' i ':.:. �µ-ri .....,..., :; ',. .EXIT DIS�H�►F�GE ,�., , iE...... ,.... . , . �. , .... , � XIT . , ............................_. �, ;: ...� :� ::: ,...... D �, ............................... . : „ f ;�� ;,.;.;. �,»: , . , ., • ` , - , , ,...,,.., '..,.,, .............:: : ; �:.h'::i,� 56 OCCUPANiS � 3' 140"'QCCUPANiS i f � � ..........u;;,,, � :� : iiiaa`;- : - i . i i ,";i'" , a .\ �y. . � � .,,, t! . � 6 ; . ... :,.. ..' : .: :i 'ir.r.[.- �i i� �. ;y . � � : f , ....,��ti1,�'i,,. ,::, r ', . �. REQUIRED ECRESS WIDTN�11 .2' . � .... �.................................. REOUIRED EGRESS WI y 2d , . ,�, `i : '£;; 's= � ' ,,, ,,, , _I.. . : i !i :: Na.7af; :. �� . ... ...... .... ":�'��':,, ��/'. :i;`>n. ..y,�; .., . , ; ;i r ^ Sy.� � ... .k. . <. PROVIDED WIDTi� ..., .,, ................... ''�,.. ........ ........ ' : j i :" ; � " PROVID�D WIDTN�39' i i � �r....J: ,.,...... ....��;;k „ II � . 77 OCCU..::: ..�jjs >.;..:.. ,.,Y%'(*e..:;� 41 ' . • • . .. . .... ...... .... . I - � �� SIDEWAL.K�60' ' eiii.»/µ � REQUIRED�` Y � � t .......................... . � . 15 OCCUPANfS 11 OCCUPMl�S... �, , � ; : . . , , N ' w., •,,� ...,... `,... i : ? . , .. .. . .. ..... RE53 WIDT 54� �f �i, . �!h•.t• , . � � � - � : - _ , � . . , PROVIDED WIDYH�45 � ' ., „ ; ;... .... .... i : , i REQUIRED EGRESS WIDTN�3'� W I � REOUIRED EGRE55 WIDTM�1 .2', � i •°��3 ������ �� .., � � --, �� ., , ,,,,,,, .,. ; '... ..... ........................7 ; ....., ;...., �' ,.... , PROVIDED WIDTN�36' eD PROVIDED WIDTH�38' ,.. ..,,3 L.,, ...., .,..1 ;, ,� �.... ' � , ....i �,,,,, � � i � t :::� i.,,,i. . . ..., .. :�, � ... SPC Remodel , ., E.. .. ...................... . ...................... .. ......... ... . . . ... .......................... I ' 'I '_� . i � ��, ^ �..:1'w':.....................::::v:::::.:,........_t�........ . . ...... , . ..... , YN.'//.ffrDltvi;lHl2 ,. ... •,.5., �� � � W��"i � r�s"`�" a Li� �� y� fo� ................d w y Ah � X�L� ... . .. �� G (�� � `'. i V ' . I Y Y : D ' .. � � .. ♦ 46 ': �. Y [ yj� yyr y Y. gY� � 'y.:+ ALLOWED T � G AGUNST D ON EG �ESS ,�� »h.Y� TL°RFr/ �i'c�/ ^� °�° k,Hy y � � . , u > ,i .Qp/� S y/�A�Q�F,j y k'MY I `v.......e........r.......a........ ..,, .ti�.. r�Al/ vNr2 � f..$� ��ry,.. 'riM'N� h�f9� �kf'. �'�� i . • .. .. ..0 .......... . i ........................ ......r............. ............ .............. .........e r................ . �...... ....Y.... .... .................... ..... . ! , � '�'� ., ' �. ,� ............ .... . ........ ..... ......._...............................................,.......,..,. �.a� P ooe � . < *„ ; � ST , � . : , ��� r».u�.-, � ' ER TO MIUNTNN , , ., , � , . , } _., „ . ,, ... • , , , , � , - , �. � ,- .� i 7 J TRAVE ER N 1 2 BC i , , , . , : , . , . . � ...,,.i , i � i ' i Y / .. / , / � � W l` • Y. '�.� 1 r � i /' 'h . . � . • Zb�i"y .V f n. /' ntii� ��''�i� � � `4 . . � � � ,� d TI ..... 4 � r . r � t � • ........r............... w u.� , " u , . ' i a� ,�' '� g; b EXIT DISCHARGE EXIS NG SMOKE COMPARTMENT EA . - t z\ r ;/ . \" v i i :/ i 3 . .... .., , ......,.. , , � .• ,. . �`,,i '/ � ; ;..` � .' / .i.,.a,;;° ', ;/ ' �, .. � ie ,. ✓i. �.i,... - i,,, c:.::,� �' �'i �e v ..i;�'�' ' o �'�; ,,,., 'r.xti:��,.sLL�..'s � ,+ , 4 � . i . __ _ _ _ __ ..� \ 4, �l �. ,.. , ...,;�. �,.,.�.........,,..�, r.,.... .,r;��� .. �� ; /� , `t : / , ,, ! / ( <x4 ; �g t q' .mCk:. .., ' ` .q././, ID .,./.b: ,..,� �� �/ , , � , , , , , ..,..,,.,. ,., . ........ : � ,,,,,, ,,; ,,,,,,, , ti . . , i� . , , ; .i ,, , � ' � t 'ati , ;e:. ": ar�s..•r� , �........... �,,........ . .......... . .� ..y -:. ... . � . / ., , .. / . � .. , :.,1!, �i� � b, . , �y ...70J �OCCUPMlTS � rh 4 51 F E I T ,� .......,.. .�....� � ... . . . ..... .......�.........., ,.......... � , . , , .., , , .. ....1 .. , , . , , �. y- . ,� �.:. . ,,,��...:. ,� ;``�::.. 6�-0�° o �� 1 3 S P CONSTRUC ION ,...... ., , ... ,, �..� r � . � .... ,., � .. ..... . ,,.., . ,.. . .:a, _.......... ��, . . . : ¢ � ,,�:.._ .�;...... 1 i . . •'i J, i d.: ".i� . k , .. ,T. s. ... J , .t �. r.. .:.. . .... .. �;�....... ... . . ..,. ,... ,.,...,,.... ........;* '� .. .. �... . i i 208 • ... �.. ' /, ',"t ,. ......... � - �, -, . /.. .. . ... .. ... .. ... ... .......... .:.......... .........: ........... .. ......... i ��t�...� �t�., �t�.. ,;�,.. �: �Ni . ...:tY' . .. ... .i , , � ,, r/.1,., i , , , .i /�,; .. ��,..; � .. '��, ��,..�; :� � , �,iq: ;;"� .1�. - � I RE UIRED E R WI , �,.... ",.., / ; - `, ', / ; ..,....�,. ..; ! i:: � ., /� .i� ,� ..../' ; : �t � , i .. . �� " � in PROVIDED WDTF1 S72'� � S W 8 . , . .. .: �::". % `H� � „ + • , /% / r , , ` --� � 1 Meadow Driv -. . , i �. , ; l, 'v r �,.a. _ .. 1 i � �� . � /� ..� /f ; ,� • � /% f `'t�`�.*` , �.t'�'`�. � M �';/ . .. ... ... ......... ........... . . ..,,.............., . ............ ............ ..,,{,,,...................._ . � +, , � . ,. ... ..... : ` .,.. ' .� . i ; ' � ,.. ,.... ......... .,, . , � : / ... ., . . ... ... ... .. . . '. ..... . . � f t , f/ , ( % / ,. '\ '� / � . , ......................._. . . . � f � t �. .. .... .. ..... ....,.... . .. .. � ._.... ....... ._. .. ... � - ... Va do . . ::. ...... �.. .. .. . . ... . , .. : , . . .. . ... . . .... . :.. .. . _. .. . .....� , . ,, .... �.......�.... . ...�.. .._. ........, , , ..........._............_ .._._....._.........................._._ ,, ;, : . . , � , ....... _. ��...... , .........................................._........_.......__...._.._..... ... ,,, ....., ,., ���:� �. ..............,. .............. ..,,_ . . � ,..... �. � t : . .............................. ....... ...,., ..,................ .... � ................. .......... � ................................ �.4 .. . . ....� .............. / �fy.. . .. ....... .......i.. . .............�...s. .. ' ... ..... ........ . .. � _ . ........ .._........ ......_._..................................._........................._.__ . .- ............................ ........ , _.... ........................._ . 81657 .., ..... , .. ..., .... ........ � ,......... ....�� .....::..... .. .. .... ... . ... . .............. . ........... .................. .....__... . �� . ..............................�. ...... ...................._..... . ............. .............. .. ......_._.... .. ........._.... ..............._......... ... . ..,,.. . ... . � � �� , ................ _�... ... .,...� .................... ........................ _.. . . .............................................. ........ ... . ................... . .._............. ........................ ..... ................�.....,,�...,, . ................_.�.:�.w:: .:........ . ................................................. . �. PARTITION TYPE LEGEND N��: ECRE55 WIDTN FOR STAIR DOORS ' ' � IS BASED ON CODE ALLOWANCE , .�� , � � � FOR EGRE55 WID7H TO BE BISED , 0k4��� #. d��£'^.o.l�'x"���9 ,C„�.�i�`t X��', „ �� , ON ACCUMUU710N OF SECOND � °�� ��`�� �3x � �n�"`R �f � �� . � AND HASEMENT CONVERGENDE . �� � 1 HR FIRE LIFE SAFETY PLAN .��_�,_�����_�,_��_��_��. 2 HR Fi� EGRESS � 1 1 � 11 � 2 HR FIREJ3M01� BARRIER DATE 2 APRIL 2007 DRAWN BY CD CHK'D BY SN MODEL FILE A1 - 1fpl .dwg COPYRIGFR 2007 BY DAVIS PARfNERSMIP P.C., ARCNfTECTS SHEET NUMBER: , LIFE SAFETY PLAN � AR 1 . 2 R2 • 1 / 16 " = 1 ' - 0 " 0 8 ' 16 ' D.P.A. PROJECT # 06938.00 l ..r-:�< � ' �' , � ,,,,.,.. ,... -., r.'; :-; � r"i ": .; ; : ' / �,..... r,,.,. . ,._,.. ; j i : i i 1 �'�, � t i � ; , 1 i . . /� t..�iil � kli,. �rf �, : i i i i t e � i ....... '�/ ' . .... �� � ....................... E f � ,...,.- ....... ..............y i i :.._.........._....: : � i i � 3 i : : : � / a '� � ^ir � ; : : � � � � � � � � r/ i i i E E � � � � � � � rJ 3 f : € � i `�.. . $ : i i : • i . � • ......................_............................. ...,...__._.....,,,.............._.._ :.�......... ................�,,........____...,,,,............._................,..... , i � :....i : .. . : i 3..............1 ; ; p ?�' f i i � ; . ..........._.......�........................................................ . . It.� , � i . E........... .........,..................._........................._............... ... I•4 ! r ............. i i i i, � � ' ... i i f i ;-...... .......,. . : �^^^?;:::f i i i i � � � � � � � � � �..._.._�e....., i i ..� � ��. .,,,........_.�.._..__._......................___...: ; i i i i � � � � � � � ..........,..._..._.... ..._._.. � � � � � � Y..., ........ : ; j i • . I � ' EI.�.. ( � ' . ; 3 � ; r � � ' � .< j j c o� p .._-I. : i : . ' , � : ................................................................ . k.:.........., i i ; lO .........,,,.....,,, ............ .............................................. f^:. 3 i i i i ..� i ? . • - : : ......, ; ...___.._........ rch � t s i ... i i i � � ; "'.F................__.. -..� ................... ....... .......... .......... .......... . \ 2 ....... ........... ........... ...,.. � : ; � � ; � � � � ' � A : : : i ; i f : f � E k �l i , : : ...... oN S r ; E . i i i � .......... i : : � : : : . . : . ... . ... . : i ° � � i f � � .�.. : ' r... . . : , i ' f � ' . . i ..,... ..... .....i. i ....y ....,.� p \ • . . . , . : . . S� ; v � . . . �.......................................................................... <..........................................................................i i...: ' i .......,� i.........................................................................d t........................................................................_ .... .... i i I i i .>l., l, c.. ...al � `, ................ i : , ` ........................................... : ; : . : : : : I � � ............. ............... . ' i : � , ' : S ; `., : : : : :................... ; : ............................,..................... .... ........................................................................_ I � i ................................................... ..... ........................................................................... � i i i ''� O � i ., . ; i , ..y ; . ...` : : I : ' ' ...._..__......... I � CAft100ASH : : : ; �;� � � � ... .............................. ". ...' ��.., .. � � ; ' �... : : � : � � ... ............................. — — — — i : : ; : : i _ i ..... � D5 �'"`.. : : ... I .... ` I : � r..... E `i . � ; • . : : ' : ............._.... . .,,,,.,,.,,........ _ : ...�.......... , . ��...� i � . : , . ! . : ; . o. : ': •(�a•:r, i i t.. �Tf':" p � � � � � � � � � t � ' ' � .... ... . ... . .. � �. ; ...r � . .................... . .t . . � -� p . . � .:�- � � � .. .. . .................. -:�-- I : : : L�b......................................i I : � : I � / � I ' .i1'Sf'4 i. 1 .i.;{rv v.3. J ttru.. I i = p::<::: ' � i 1 y . � iI I I . . . . . . . . . ,................... : . ; j ; E _ � . . 1 Y.................................................................... .......5 � : I / 1 .�..................� � �.......... ..... ................. i : ; : NO WORK ; ; �,-::::::::::.. ..... i � �,, � ; I p � E c� f ;... ................................. ...:::::::::::�........ i *......... 15 � 3 : �..........:.....: ; : 4: :i ; t : / 1 t................... � ......1 .... . . . ; i : ; j ' .......... � . ; .................: � � L _ � ;;... � � . ;....... . . ;. : . : � : : _ _�, _ ; � ....� .... .......... ......... .. � _ _. - ��,- ; � ...., � . . . ......... .......... ........ .:.......... .....� � . � , � + , , � ` ;. ...-. ... ,� ............. sao, ew� ar., sr�. �+oo J � � ; � : .... � � ; , �-�1 : � � . �.... . ; � i oo : , � , � � ; ' � � � � � �y � � 'z.?��.................... . . . i i i - i t � � � �� � � �Y... � � �r.;::�y�. � � � � � i i : i i . � . � �............. a ; ' �..... .............. � : : ; ; NO WORK : i : : NO WORK t........................._�................... i � ; : �.....:• .. 3 � � � i i � '! � �2.0 ..�.................. DBiN9i. COLORADOl�6 . , . . . . . , ; . ............ .... . ; � . : ........................................................._:.....................: ...........: :.........I................. _ � I � ................. ; ..................................... : : E i � i ..................................................,....... .................. ........f ...................... .. ........r, i ir's .................................A i ..n. .. � . ' .... .. .... . � .... .. i : ........... .... : : : .._. - s0�.l01.l6Q6 F.s03.lM.sOZf ., < J . : ................ ............... ................... ........_... � : � : t ....................., ................................ ... ............................................................................................d k� - - - ................., �....� r�............................,............. ; : ... ..................................................... ........................ . ....................................... ............. ,t;...;., ..t..........................,..............; ....... ....... : , . . .. ............: : 1 - - ... � ,., . � ; ' � � j ° � t 3 � ,, : : I I E, : : ' � ;��I I PUS M 102 r .......... i � i i ti...,.. � � I �........�.J..._ `� `, O � i�.� Ft� M6�2� .............._:.;.._................................. , i H .............. ........................................ . : � ........ . ...................................... 9� ; _.... , .... ; C ' �* �.�, ' I 1 4., � � . . �..� � \. i i .. s _' ' i — ............i _... ........... ........... ...... : : ` _ I I ... .. ...._ . ( I , . �� � �.. I ` ,.�: �,. ,:� •........ � i ; C, :.,f . . ; .ULi:"' I ,.... �_ � � ...................___..... ; � : . - a , ...�.:::::::....a � . _:_::_ .... � , , 4 , ; ..c._ _ , ... , , o� ...,f : � D4 i � D4 I CORRIDOR SPC HALL � 3 / � � � I i I � � � l�' .0 � 02 � / ; ' '; i � 0� Z ' i . � L _ -� - - ' � r.- ' �... I : ' F C i � .. :.....: - - o J . >................................................:- - - - - - - - - - - - - - - - - - - - - - - - - - - } ..,...............................,..... � � .....7........................_.............:- - - - - - - - - - - - - � REFERTOA0.0 FOR KEYNOTES r� � - - - - - - - - - - - - - - - - - - - I'' �'�_� _ �; ... � _ ..I ....,; ` � r � � _......._............._:... � �. il ' ;�I �::::........._ o v ,..�;; � s`t:°' ; '• : 1 � i j ; � I � ` i i i i i I � � : 1�11 _. � /��-Hd� 1 C310N 103 105 106 ; � , . �` � ; . . Y�; 3 � � . .. . ...... . . . ..... . `��.�,I � � � . .. � E ; i ' '. ` i i � � i , � ' __.. -.��.__.................:.......;..........., : ' _ ..._...........................,......._..... 7 ...._..........._. �. �� � ti � � � ..........__.......... J I ,� _....... ......._. ......_......�; ; . i � . , ......_�...�::... ...... ` � NUC MED STERILIZER I � I ,....... ... -'1: i i � �� � _ � ' � � � � � <,�;;... ,. .,. � .. rit.. � . 0 ( y Own ) , ' 8� : ; .., „ f i.�:�2��,.. I L ; , I �'~ /_ � � � � 5'-6" I ; 2 1 ' B' b er 'v 105 I; ; � °2 � , ,..._..........., , i i : `_ l_� 13 �-� � : : .................................................. � - �- . :..................: ; > i" � ' � , ' ' � � /-� '�l '� ^ . .J ;r � � � �` ; � � , � I � :.......... ......_.._...._. �.J J.. ,'; ' ,:� ;;� b Owrj v 3:::::::::::::::::::::... � i i � , i � I I � YME er) ... ..................... ; . . : ; ; . i ; , ;...... ._� ... ... ........ �: � . .. .. ....... . . . . ?w ., >... i ; , , i i `..... � �, � - -- i � D5 -f.::,-:::•::::^.,.: ,..�.._ � t..."....... ;....; I ' i � L - - � � - - - ' i O i `t � 1 , rock 'i 1s'-1 " I''i ' : . ., I ,, � I i ; ' ' ; � i r - - - - - � � ' ....... . _ �, - ' DONet 8'iRffl', 8U1TE7E Z' CQ ... ..� : O , I ; �.. .,..;;... : � � 8• ,3� �• I ; i D5 ' � ; ;;,ti : � � D3 � � � � r - � ` I , ,.... ; ; , 1lSTERILIZER I LAI�WOOD� CO �2'la 8' S' CG ; ' ' ' R ' safe ' ' STERILIZER W �.............: I I ,,. �_ ; : ; u:::�; ' � i � i i �a ;�, ,�,. .. � .._. < ' � � 106 �by 0 ner) ; I •......:.......:.:�,. ,,, D1 ` � , �_... : .:.. ' ; ,' .................................................... .. i : I ' � � ;, � ; I ' I WORK �� - I ISSUEIREVISION DATE NO. ,: ; ; .......... ................. 0 � � � � i i � :;;r";' i I 104 � - ; , :.... ... 0 H � � ; � � : ; i ; D5 � I � i , � 0 9 � ' � TOV CODE REVIEW 1JUNE07 , , ..........._: � I � � ! I € � ; : ( � ...... _ _ I . I ' - � � I � ' � I i 12 nz.o 10 ASI # 1 13JUN07 ' ' i . ; i � I � `it.:.;;s........_� i' � ,. ,• s° � � � ....a ' � ._.� ; � � �, ,,�,.,:.:,.. � � ; � ..... . ; , � � � ............................................._: TERILIZE _ ..,...._..___...........,_..............: ._..._.. .�......_.,,_ ; ,......::::.....; ; I � i� i i :..................� , ..............................: :;_ _: I � ;o - - -..._ � (by Owne) .... � ;.�::::..., ; � � � � ' ..... ......... ; ; I STERRAD I .,,... _ ; ; : i i i� . .. . � �g ;. _ . ;� ..... ;;•_; , ; i i i i ` i ,,.,,,,, , `` ��, ,, � � CONTRACTOR TO COORDINATE '� , STERILIZER ' ` . ..... - i i � i i i � , ....,�.::::::::::::%;' � I — — — EQUIPMENT LOCATION WITH SIEMENS � - ' (by Owner) ' ' ` I I ......_%: : - : ....................< ; ( D3 _ J � . . i ( ' ,.,..._...........,.__._,...__ TR ; f : I ' ! .._,...__......._................ _. ; i ' - - - - - - - - i : _._.1......1.1..............__..............................._....................�....._..........................._......................................._.............................�..1......................._...,............................................__.�..__ .................. .. ..,..................__............................___.....................____................................__..._.,.......................�.................;.......:... : ;........._..........................._................................._.. .. ............ ....._____........................._..___..............................,.................... ...............................,......... ......_..........................._............... . __............. . ......_...................... ......__............... .._.................. .. ..........,...:.......;... : �.� �,. � � ... ... .. ...._ ..... � ..............__......................._................................_.....................................................................__...................__.................................._..........................._......................................................._...._..._....................................................__.........................................................__...............................__........ ............_....._... ...,..................................................................................................................... ...._................................_..._................ .......__........_................................................_........................_....................................._........................._._..........................................................._......__.................................................._........................ . ; ..... ; ; �- � ; n.._ , ; ; � � 4 ' � � J : : ,- � � � � � � � � � � � � � � � � � �. � � � � � � � � � � � � � � � � ~'�� l � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � : ; ., ._, v........ , : � I� \\ ; ..,. � : E ' f , DEMOLITON PLAN 2 FLOOR PLAN A1 . 0 � �4�, _ 1 ' - 0" p 2 � 4 � A1 . 0 � � 4,� = 1 ' - 0 " p 2 ° 4 ' ................ �`. : !�, �� . < . ;; � 4 ! r : ' € � � �`�\ , : ; . . j ^ .✓ . . .. , �f . .................z::::::_ .. ' ..,,,,...........}. ' � � ` . ........,............. ( J . . ' � : i i i � i � � i � V 5'�, f � i ! . ,. r ' ,.; . £ v � � � � � � � � � ° f � �. . � � � i ... .. . . , . ..�. ' .. . . . � � ...................................................................................................... ...................... . 3 i `: , I � .., i.; � � , , , , � ; _.............�......__._...ry..............����l� 5 � , . .. � { Y �M / r f f i � � 1: . � � � ; � ; _ , ;. , ,:.. ; �`o , ��. ...............n................... .................. .. f y � , �, :' . i � ' , ��� /i5 �,: ,' �';'��� � � � � � : � � � � i � �'S r � J, ., . : ....� ... -� ._ � ; - r , � I ., :. �... . .. , , � ; . . . . . , y I . , . : , .. .,,.::'? � u � ��s '� , : � � � , � �� y:� �' . ,•;; �..;�,:. ..,�,: � � �, , . � ..... ..........................� 'LJ' �':;�C'�/'/ � ...r — o ma.. 7 . . ................... .:..� ';, . > <, ,, i .: � , ' � • ' ' r t -..,.......,. :. , . � ,. ... .. :. .., ................... ....,,.,,.... . . ,,.....,,,. , ........,........ .,..,,......... . ... . ... � . ,', (;+ �'. :.. ' . ` `, � . ' ............ . . .._....... ................. .... _......... . .. ' � ' . , ' .. �� . ,. . . , �.. � ., . . �..� : , y '... .. : .; . . . . . : .. . . . . .. ............................................. „ . ... � : ,i. ' � .<., � ..s � . . .:" .. . :, � , ..,,: u � �`�...�.�..._...�-•. ' . . . . . , '; . � '�:. .�'� �.. ' ��:: I f '. .. .w+ -fn . : :... r ....H � . . �.. � . � ` � . �: :' ",.4 �.1! ,. .. ". . , . l ...: . . : ( ♦', . �.:, . .. , Y . . ' .. ... ..r � . � ; ` . / �{'�. �: , .i '. � I :` .�� � A ' . ........ .N.. ...........' � � n �� '. �' � � ��: . � .. ' . . I I �'� !S `:. � I � � � . . l� .. �. � . .� '.w. .; . ....�. .... � Y . . . � . .�. < .... .................�..................................................... . . N . �n.h .. ..a ..: � ..6a' H.a�. ' . . . ., : . . . . � a e . . . , : . . ' , . . . � �.� . . .,.�... ' � ".: : : : �1� i > r � . ;. . . . k \ , � .. . � � ....., rt .. . . � . : : h " t �Y �, � f f '.: ; .: ' ., � . . ., . . ". � � � � � 3 n � L � , � h '; Y Y f h { 6 . 1 4 x. J� . . 4 0. :: � , AFlIl1 ;rtK 1wY� ,J�� 'r,R!M iYi�l � � � �....�._..., r x+ � '. ` � ;;i:r , E � , . r � ... . . . . .. . . ._�... ......................._. ......... ....... .. . : � . � ._...... ................__....... . ........._ ...._...__.. .... ; ...�...a d , , ......... ........ ...........W_. . _ .. g ; ...... , :, . ..........._......... .......... �7 ...... __......... , . , . ;. , _._ <� , .. E � , ... " � „ �...a1 �� �,� � ` EXISTING GYPSUM BOARD CEILING ,,: �`.,, z ' EXISTING SUM BOARD CEWNG •' � ,,;; r � ;;; r TO REMAIN; INFILL FLUSH AS ' I `�. , ' TO REMAIN; INFILL FLUSH AS " ; " .:.�.::�„ '' ` ':REQUIRED FROM REMIOVAL ,; ' `-� � � � �10� ';REOUIRED FROM REMOVAL � ...... � € ;: , � --••••-•-•-----�---�---�- - • OF LIGHTS OR OTHER DEVCES " s ' ;OF LIGHTS OR OTHER DEVICES .. � , , , , , Y , ,, , ,..' y.............4::....:::::::::':'o:::.f............. � . .. .. ' : : , . r . , . . ,' ' . ^. . .......... . � v� . { b.. :`y . � . .. , I ,�,� OR � ;,;,, _ w„ — � I `• ; � �- y ' „ :� � ;- �l :. y1 ax Y�. � 2� �� - Valle ............ .,................_a.............;...e � ` E4tJ � i. �� ... ' � . . . ' . � / ,.�,: ' � ' R��� I < �tuyl��> i�i i � . r.. '.::r. / . ' � v: ., RL 2 �4UAL I � .... �./ . V: � ' .. . � � . 9 ......... : � :: . . ,' t f I 'ifi 'a : . ;, , ; .. /�`�� . _ .., ; �.� .:; � , ... . ......, ....a ,, ..,.�. . ... .. �. . ..... . �.... : . e al _ .. .. . x ......_.._.w._.._...._...�.... � .. � M dic ,; �; � , . .. ..... . . _:::. -::; � : � � ::::::::::::::.:�... . .... ......� , � � � e ter .........::E;,...; 8 -0" . � � pR PROV IE GYPS M WRAP ED ; ; ;I ; � GYPSUM W PPE ......... .......:........ .......t.... HEAD R AT OP NING, B Tf01� � ' � r......... ...... , OVIDE I n � ; i � F D ' •7B�� OM OF D ALL T BE 7' 6' ; .................:...................i.....,...........: ; � L T ' ; , ; O H� ER ;AT NG, I I EAD OPEN r,pw.�.�.¢e.,!y...........:.:...:.........:....:� �. � f � ' `` ' '" � � ' i noN _ ........ .. ........ .. ....... ...... ..................< <. Rf �..:+... . �, . 4 : ;;;�.`.,;.3 :,. ., �� I i � �.: :'; . l,, �': � �� ': �. � i E � y � ., , ... .. . . . � i i i 3 < '. .,, . . '. s .�... . : ' .; ., . . t�l�NM'�.i4`.uu.�...n.�.r.b��.�q.y(�:�• � ......... y ........... .. +..................F.... O I : ..nn. un..n.. � li ' O O ....#. ... .. ... O„ .................. O { I �' � e ... � V I r I '.. {� . .. � n: . . I 1 � j �2 , ..' . . r . . �........... ............... ...� � �.. � �.... .. .. I I '. : 5. '�.. .� �..........n.... ' .................... . '. ' . . '♦ .... . . ..... � �. ................... ..rn...o....r:...n.�n..uYS I . ..... .......... ... ... ........... ........... � ........... .......... ........... ................... a[ '. . . . i...... ' .: . � ` � � ..... n 6... nr. � � � � . y.�� .� '..... + ... .....I .... I . � i � I , ' ...u..�. : � I I . . .... ... .... .... .... .... . .... }•� .... .. Y . . � I �i ' I.. �.rv[ ... .. . . . : 1 �I I ' � :..:. ...�...:,,. , � , . . ..... .... o . ... ........ :..... :.... F � rst Floor : I s,..:. �;, . ::::.; °, . ; ,.... ., � � � 8, _6 „ I «...... 8 _6» y.. � .. . ' � € ' ' � . 4 . , .. . :.. , � E i ' ' � i t�::::�:;::�i,�y,,:;.;>::r;:`.::i�,:�.ii � , .... .......... ........... ........... .._....... ............ ........... ,� ._� , ' : ...... ...........,....... .................. ........................._> : .. ' . ; : , ` € !.... � �' � .... .... .... ...! . . : I � � � Nudear Medidne . , � . � . � � ; , �R . . , ,, ; , . . , , � , ..: . .:. . . ... : .:.`, � ' L— lVb J ' '. ; .... . ....... _ � � � � 0 � , ,: � I , � I O O .... ..... R :.::.:. k � .... ' .. � ; � SPC Remodel � : � � � f 1 ' i ; : � � �.�:::.�. ; o .. . ....... ... .... . ...... .. ...... .......... . ...._ . __...... .... ; � � ', ,°: 7" . '/ . . 3�'.'��,, I ; 3 'i I ' ; i .... ....... ; � ... � ... .... . : . : ;, : ; 1 � .. ... ..... �..... ; : .. ... .... � . . t , , ......... ... . ..... . � , .... i I � � . I Y I 9 .. . ' i I � I < i I � i 181 W. Meadow Dnve � < < � i. '� :�. . •�". i, ' .� : . � � � I I : tn...............�..n.rvi...q......x...nJ t : ii . I : : .........�........ ... . � .. . . � .. i .............�.. �........ ........�... . .............. ................... ........... ..... ........... ... ....... . . ..... .... . .. . . . . . . ..... . ..... . ....... . ` .... .......... ......� ........ .. . .............. ..... ......0 .............. . ....�............ . .... ........... .........I.................. . .......................... .. ....I...................... .. ...... ................ . . ................. ........ . .... ................... .. ........... ............. ... .e.......n...� I � . . . . l :.: .... . 5....... ............ .... . . . . . . . �. .r.. . .i.. :. . � I. . . i ...ul G .. ' r.. � .. 1 'J'.. I '( . : : . .. . . . . . ) . .�. ..................... .�....��................ ....................... .�................... . .�...................... .........�............... ................. . ................. ... ..................�... ...................�. ................. . .............. . ............... .............. ............... ................. .,- ., � I, > ; ,_ ; ...... .._....... .... ......__ . ...__ ...... ...... . ............ . ......... . .......... ......_. . ............. . ......_._..... ......_....... ................... ......_........, Va do � il � Co ora ': : M� �:::;;:; ,r,, .. : - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - --� -� 81657 . ....... .;::.....: . ,:..,:... . . , _...... : , , ; : , . .; ° ? . . ... � : [ � . . . • . �.�. .. . i ! I , ', 3 REFLECTED CEILING PLAN A1 . 0 � �4 ,� _ 1 ' - 0 " p 2 � 4 � DEMOLITION , FLOOR AND REFLECTED CEILING PLANS DATE 2 APRIL 2007 DRAWN BY CD CHK' D BY SN MODEL FILE A1 - 1fpl.dwg COPYRICFR 2007 BY DAVIS PARTNERSNIP P,C., ARCNRECTS SHEET NUMBER: A1 . 0 D.PA. PROJECT # 06938.00 REFER TO 19, zo, z,i�. , DOOR AND FRAME SCHEDULE FINISH SCHEDULE FOR JAMB AND HEAD DEfAILS 2 -�• , -O6• N0. NAME FLOOR BASE WALL CEILING REMARKS DOOR NAME DOOR FRAME FIRE HARDWARE NOTES 3'-0' 2" 2' RATING SET NO �* 6' 2'-0" 6' �MPERED ��� �'PE WD HGT THK TYPE HEAD JAMB - - - NORTH EAST SOUTH WEST � �o ��S • N 100 CART WASH D1 3' - 6" 7 '-0" 1 3 4" F1 1 A2.0 2 A2 .� A 14 GA GALV FRAME; 100 CART WASH CTF1 CTB1 CTW1 C11N1 CTW1 C1W1 PT2 FULL HEIGHT WALL TILE � ^ 16 GA GALV HM DOOR 101 CORRIDOR CPT1 RB1 - PT1 PT1 PT1 PT1 � 0 101 CORRIDOR D3 4'-0" 7' -0" 1 3 4" F1 1 A2.0 2 A2 .0 - - - B WOOD DOOR 102 SPC SV1 SVB1 PT2 WP PT2 WP PT2 79 PT2 WP PT2 ACT1 4'-0" HIGH WALL PROTECTION � • � Archit tS N N 102 SPC D3 4' -0" 7 ' -0" 1 3 4" F1 1 A2.0 2 A2.0 - - - C WOOD DOOR 103 INJECTION SV1 RB1 PT1 PT1 PTt PT1 ACT1 0 0 7EMpERED ° 104 WORK SV1 RB1 PTt PT1 PT1 PT1 ACT1 ^ '� GLASS " 103 INJECTION D1 3' - 0" 7 '-0" 1 3 4" F1 1 /A2. 0 2 A2.0 - - - D WOOD DOOR 105 NUC MED SV1 RB1 PTt PTt PT1 PTt ACTt . 0 0 105 NUC MED D1 4'- 0" 7' -0" 1 3 4" F1 1 /A2. 0 2 A2. 0 - - - D WOOD DOOR 106 STERILIZER SC RB1 PT1 PT1 PT1 PT1 ACT1 � � 107 CORRIDOR VCT1 RB1 PT1 PT1 PT1 PT1 PT1 106 STERILIZER D1 3' - 6" 7 '- 0" 1 3 4" F1 1 /A2. 0 2 A2 .0 - - - E WOOD DOOR �� ��� � WOOD/MEfAL DOOR WOOD DOOR WOOD DOOR INTERIOR ��� F��� WITH WINDOW WITH WINDOW HOLLOW MEfAL HARDWARE GROUPS LEGEND FINISH KEY � � � � ��� D1 D2 D3 F1 °'°.°°°.°°°° F.�'°.°°a°°°' DOOR TYPES FRAME TYPES Group #A 3 HINGES WD130S RHOX 4 1 /2 US32D MC - NON FERROUS GL - GLASS UM ABBREV. NPE RECOMMENDED MANUFACTURER SIZE PRODUCT ID & COLOR REMARKS 1 PASSAGE SET 626 1 WALL BUMPER WS407CCV US32D IV HM - HOLLOW METAL SC SEALED CONCREfE CLEAR 1 PROTECTION PLATE K1050 10 X40 PUSH US32D RO MIN - MINUTE PT - PAINT STL - STEEL ACT1 ACOUSTICAL TILE ARMSTRONG 24"X48" SQUARE LAY-IN CLEAN ROOM VL (NONPERFORATED) Group #B 3 SWING CLEAR HINGES T4A3786 5 X 4 1j2 26D M� T - TEMPERED 1 PUSH PULL LATCH HL6 US32D SC CG CORNER GUARD IN PRO 48" HIGH 150 HIGH IMPACT W/ ELECTRIC STRIKE 4840- 60 ggg LCN BE - BEST WP WALL PROTECTION IN PRO 48" HIGH ROLL SANPARREL GT SHEEf - OATMEAL CAULK TO MATCH 2 TOUCHLESS ACTUATORS IV - IVES 1 SENIOR SWING AUTO - OPERATOR 9540 PUSH SIDE ggg LCN LC - LCN PL1 PLASTIC LAMINATE WILSONART 4813-60 NICKEL EV (HORIZONTALS) 1 PROTECTION PLATE K1050 36"X46 " PUSH/8" PULL US32D RO MC - MC KINNEY � > PE - PEMKO PL2 PLASTIC LAMINATE FORMICA 958-58 BEIGE (VERTICALS) I , , 5/B" GYPSUM BOARD j j, , 5/8' lYPE 'X' GYPSUM BOARD E 4 Group #C 3 HINGES T4A3786 5 X 4 1 /2 26D RO - ROCKWOOD ; � i •, MC SC - SCHLAGE ' ; I ' DOUBLE STUDS BACK TO BACK AT JAIAB 1 STORE ROOM LOCKSEf ND80PD RHO 10- 025 626 S C ; + � � i 1 IV PT1 EG SHELL PAINT SHERWIN WILLIAMS VELLUM SW1116 1 WALL BUMPER WS407CCV US32D MTL. HEAD TRACK 1 PROTECTION PLATE K105� 36" X 40" US32D RO PT2 EPDXY PAINT SHERWIN WILLIAMS VELLUM SWttt6 � HOLLOW NEfAL FRAME I�TL. CLOSURE TRACK PT3 SEMI GLOSS PAINT SHERWIN WILLIAMS CROISSANT SW1114 HOLLOW �IETAL FRAMES �� RIJAAABA�BOCM,1�, 00. ` ' ` Grou D 3 HINGES 26D M � ��DDONFJt87R�T' BUI�EY � � : CAULK FRAME 70 WALL � � � ; CAULK FRAME TO WALL P # T4A3786 5 X 4 1 /2 , � 1 LOCKSET ND53PD RHO 10-025 626 SC �' � �6 ' ' '? 1 WALL BUMPER IV RB1 RUBBER BASE ROPPE 4 HIGH U N N E R S A L W E L D E D S T E E L S T U D A N C H O R S, WS407CCV US32D " # 172 CHAMPAGNE N ^�y N �' � RECESSED 1 /2" FOR STUD AND GYP. BD, 188UEJREIIISION DATE NO. ' � �----�- ------ -- -- CPT1 CARPET LEES CARPEf BROADLOOM D7006 BELLO 203 MESA � ��� � �� Group # E 3 HINGES T4A3786 5 X 4 1 /2 26D S� TOV CODE REVIEW 1JUN07 WOOD DOOR HOLLOW IAEfAL FRAME; RE: A0.2 1 PASSAGE SET WD10S RHO 626 ! 1 WALL BUMPER WS407CCV US32D IV SV1 SHEEf VINYL MEDINTECH ROLL 86497 BRUSHED SAND WELDING ROD TO MATCH ASI # 1 13JUN07 �' � SVB1 SHEET VINYL INTEGR4L BASE MEDINTECH 4" 86497 BRUSHED SAND I � WOOD DOOR RE: A0.2 CTB1 CERAMIC COVE BASE TILE AMERICAN OLEAN 4" HIGH GLOSS ALMOND 0012 VERIFY EXIST. VERIfY EXIST. CTW1 CERAMIC WALL TILE AMERICAN OLEAN 4"X4" GLOSS ALMOND 0012 NEW PARTITIONS NEW PARTITIONS CTF1 CERAMIC FLOOR TILE AMERICAN OLEAN 2"X2" UNGLAZED CERAMIC A�OSAIC LINEN A07 COORD. WITH COORD. WITH PARTITION SCHEDULE PARTITION SCHEDULE G1 FLOOR AND WALL GROUT MAPEI ALMOND 48 �I HM DOOR HEAD 2 MH DOOR JAMB VCT1 VINYL COMPOSITION TILE ARMSTRONG 12x12 IMPERIAL TEXTURE SANDRIFf WHITE 51858 A2.0 3" = 1 '-0" A2.0 3" = 1 ' -0" ,,. ..... � PtASfIC LAMINAlE OVER 1 1 /4' �i � . MDF BOMD ON FRT BLOCKIN j �# 5/8" TYPE �X ' GYP. BD. 2'-1' 2 -t O �r �� t t 1 '-3' �� ' '' CONTINUOUS DOUBLE � � _ .,� ✓ \� ! STRUCTURAL STEEL STUDS � PLASTIC LAAlINA7E OVER 7 ��4• b , ! � `�'` MDF BOARD WfIH PVC E E 1 �" ' AT EACH JAMB, SILL AND �P� BD. ; GYP. BD. � 7( � HEAD; WELD TOGEfHER AND EXTEND TO STRUCTURE l '� � i � ADJUSTABLE 4' BACKSPLASH DRAWER � li DR4WER • � ��sxi�s• �r REVEx � � /� i , 4' BACKSPIASH 'n� Mo�aNC cxr eec��r • �' �/�r �° si W �• ' GYP. BD. ' SHELVES - .........::.".::.::::'........ .�""" .°�'."..� MODEL +DRMF-SO-50 OR �'�•r ` '; COUNTERTOP � - -' - QUAL. INSTALL PER �� fJ ' ' -_. _. 20 G4 SHEEf MEfAL BACKING I ; Q �� � ' , uF�cruRe's "�`S�D r'��+°-'� ,.,;�' � o I • RECESSED STANDARDS DRAWER � � RE MENDATION. �.�,,,,�.,,�..�•r • ' � F 20 GA. SHEEf �IETAL BACKING I PuHr EAL BLACK `�•••--• " N � COM. BEHIND CASEWORK „ � ADJ. SHELF I' COUNTER TOP � CONT. BEHIND CASEWORK . . -_. _ s � ', W � ( � � 20 GA SHEET MIETAL BACKING " .- • SHIM , AS REQUIRED Y� PLYWOOD BACKING ' ' HOLLOW METAL FRAME ' � • �' CONT. BEHIND CASEWORK DR4WER • � PI/STIC LAMINATE MRON WRH Y ; � � � '�j � FROMS :. . i N � o SUPPORIS AND WIALL BRACKEf n % TEMP REDA GLASS tx WOOD BLOCKING � � RECESSED '; � Y� PLYWOOD BACKIN i ! �� FRONfS � �' FRONTS , �STDS. � i Y" PLYWOOD BACKING ............ ._DRAWER ....... ............ ._ � • S/6' CYPSUM BOARD 0'JER � 1 x FRT WOOD BLOCKING � � � J 5/8• zo �auo c�cuP ro 1x FRT WOOD BLOCKING FLOOR WRH ANGLE VERIFY EXIST. __ 2x FRT WOOD BLOCKING 2x FRT WOOD BLOCKING C.i M �' " • P ........... \ NEW PARTITIONS � � COORD. WITH COMPACT 3' 3" �� PARTITION SCHEDULE FLUORESCENT FlXTURE ���� 3 HOLLOW METAL WINDOW FRAME 5 UPPER CABINET W ADJUSTABLE SHELVES 6 CABINET W ADJUSTABLE SHELF AND DRAWER 7 CABINET W 4 DRAWERS 8 SECTION AT WORK COUNTER �.0 3� _ , �_o- �.o , � - , �_o�. A2.o , � - , �_o�� A2.o , � - , �_o- �.o , � - , ._o�� Medical B Center 5 8 n2.o 3� ^2•o nz•a SIM . 2" HO%W MEfAL PAIHTED FRANE � 2�-� � �-6� � � -3� 3'-0" 3'-0' PARTIAL HEIGHT STUD WALL 2" HO�W �1ETAL PAINTED FRA�1E FULL HEIGHT WRH 1 4' TEMPERED GLASS WfTH tAMINAlE CAP WfTH 1 4 TEMPERED GLASS IN 3' WRH AQJUSTABLE SHELVES i \ / \ . � � � ..�.. ...._�. .�...... ...�. .. . ._ � � � , _ � \ � �\ f � i.� FEP . .... ......../ . ....... ..... .. ., . r. � N %....... ....../ FEP ...... .. . , ./.... ... . ........ ........ .. .. 7'-0' M , � L2 : � � �----.. _� _ ._ �' o , UCL I � / � o ' ! . 1 .. � , o0 0 0 �- - � , ; . ..... . t F� ; � � � � � � n ...... .. ...p�.�...... .. ..... . r't �........_ - ....., i ' ' ° - �P� � �P Firs oor � o I ......_-........................ ' � E uc� _ I SAFE ; I, RACK o0 , - � � � N ................. . N o � � ,� , - ..... . , .......... ,.... .. � , ir.. ...... ....i1 ... '� �" • /1 K� • ', � --t- N °° o o � r � � o o - � • N - Nudear Medidne M �n � � ' � � � _ �EP �, � I � � .. . . \ ....................................................._........................ 'r, ir, i Fn r� � � i i+� %'� , �� i � � ...... .... . .. ... ................ .. . . .......... . SPC Remodel , � ....... , , . , PL2 . �::::::::::::: :::::::: :'',.;............................; ............... .......... CORNER GUARD 2'-0' 2'- 1 " 2'-9' 2'-9' 2'-0' 2'-0" 1 '-6' 1 ' 6' 2'-3' 6�-�� 6'-6' PIASTIC LAMINATE SUPPORT 2�-9� 2�-9� 3" 3" 3� � � EILD VERIFYCWIDTH� OF NCABINEfS � � TO PROVIDE 30" REQUIRED �2.0 �2.o CLfARANCE IN FRONT OF PANEL � o WORK � 04 181 W. Meadow Drive 9 WORK 104 11 WAITING 100 12 WAITING 100 13 WAITING 100 14 WAITING 100 �/81� �i0�01'8d0 A2.0 1 /4" = 1 ' -0" NORTH A2.0 1 /4" = 1 '-0" EAST q2,0 1 /4" = 1 '-0" SOUTH A2.0 1 /4° = 1 ' -0" WEST A2. 0 1 /4" = 1 ' -0" WEST A7 . 1 1 /4" = 1 ' -0' NORTH 81657 2'-8' 2'-8" 2'-8" �� � o ;�- �- � � -� P,� - - , SCHEDULES, DETAILS, AND " '�- INTERIOR ELEVATIONS � , , . m N � I ^ N ................................................................................... DATE 2 APRIL 2007 io ' DRAWN BY CD � - - - N ................................. CHK' D BY SN 1 '-6" 1 '-6" 3'-8" 1 '-6' MODEL FILE AO-2.dwg ��� ��� COP1'RIGFR 2007 BY DAVIS PARINERSHIP P.C., ARCHRECTS 8�_5. SHEEf NUMBER: 15 SPC 102 A2 . 0 A7 . 1 1 /4" = 1 '-0" NORTH D.PA PRWECT # 06938.00 NOTE: CONTRACTOR TO COORDINATE STAGING, STORAGE, PARKING, CONSTRUCTION ACCESS AND RELATED ISSUES ADJ . ADJUSTABLE INSUL. INSULATION APPUCABLE BUILDING CODES: WITH THE OWNER PRIOR TO COMMENCING WORK. A. F.F. ABOVE FINISH FLOOR KBT. KEY BOARD TRAY 2003 INTERNATIONAL BUILDING CODE AL. ALUMINUM MECH . MECHANICAL 2003 INTERNATIONAL PLUMBING CODE 1 . ERECT AND MAINTAIN DUST- PROOF PARTITIONS AND CLOSURES AS REQUIRED AND OUTLINED BY THE HOSPITAL B•0. BY OWNER MIN . MINIMUM O � � 2003 INTERNATIONAL MECHANICAL CODE TO PREVENT SPREAD OF DUST, NOISE AND FUMES TO OCCUPIED PORTIONS OF THE BUILDING AND TO PROVIDE CFT. CERAMIC FLOOR TILE MTL. METAL 125 DOOR IDENTIFIER �`� �^ DETAIL IDEi�TIFIER 2002 NATIONAL ELECTRICAL CODE FREE AND SAFE PASSAGE OF PERSONNEL AND GENERAL PUBLIC TO AND FROM OCCUPIED PORTIONS OF THE CONC. CONCRETE N0 . NUMBER \ �� 2003 INTERNATIONAL FIRE CODE BUILDING. CONT. CONTINUOUS O.C . ON CENTER ^� • � 2002 NFPA 72 NATIONAL FIRE ALARM CODE CORR. CORRIDOR P. PAINT OFFICE NEW ROOM IDENTIFIER AMERICANS WITH DISABILITIES ACT GUIDELINES I 2 . GENERAL CONTRACTOR TO PROVIDE PROTECTION FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION 000 WORK TO FLOOR AND FINISHED SURFACES TO REMAIN . CONTRACTOR SHALL MINIMIZE INTERFERENCE OF C .M .U . CONCRETE MASONRY UNIT P . LAM . PLASTIC LAMINATE LIFE SAFETY CODE-2003 NFPA 101 � � - � Archit lS CONSTRUCTION WITH ONGOING BUSINESS. CONTRACTOR TO CONTACT OWNER A MINIMUM OF SEVEN DAYS PRIOR CPT. CARPET RB. RUBBER BASE LJFE SAFEiY SYSTEMS: AUTOMATIC SPRINKLER SYSTEM AND DETECTORS TO COMMENCING DEMOLITION TO SCHEDULE WORK . CWT. CERAMIC WALL TILE RE: REFER � DETAIL SECTION IDENTIFIER THROUGHOUT THE BUILDING. -- -�------------------- ----- INTERIOR ELEVATION REFERENCE 3 . CONTRACTOR SHALL KEEP PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS AND DEBRIS . REMOVE DBL. DOUBLE REF. REFRIGERATOR ,,, , � nt . t OCCUPANCY TYPE AND CONSTRUCTION: PROTECTIONS AT COMPLETION OF WORK. PROMPTLY REPAIR DAMAGES CAUSED TO ADJACENT FACILITIES BY DISP. DISPENSER RM . ROO.M OCCUPANCY: B DEMOLITION AND/OR CONSTRUCTION WORK AT NO COST TO THE HOSPITAL. DW. DISHWASHER R .O. ROUGH OPENING CONSTRUCTION TYPE: 1 -A EA. EACH S . F. SQUARE FEET EXISTING FIRST FLOOR BGSF: 53,869 S.F. 4. DO NOT SCALE DRAWINGS. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS ELEC . ELECTRIC SIM . SIMILAR REMODEL AREA : 1 ,432 S.F. - " - " ' - BY OWNER 2301 BLAKE ST., STE. #100 THE SAME OR REPRESENTATIVE FOR ALL SIMILAR CONDITIONS, UNLESS OTHERWISE NOTED . DETAILS ARE USUALLY ELEV. ELEVATION S.S . STAINLESS STEEL PROJECT DESCRIPTION: DENVER, COLORAD080205 KEYED AND NOTED "TYPICAL" ON�Y ONCE WHEN THEY FIRST OCCUR AND ARE REPRESENTATIVE OF ALL SIMILAR EQ . EQUAL STD. STANDARD O WINDOW IDENTIFIER RENOVATION OF AREAS WITHIN THE FIRST FLOOR OF THE HOSPITAL. EGRESS AND 303.861 .8555 F.303.861 .3027 CONDITIONS THROUGHOUT, UNLESS OTHERWISE NOTED. EQUIP. EQUIPMENT STDS. STANDARDS INFECTIOUS CONTROL TO BE MAINTAINED AT ALL TIMES. 0225 MAIN STREET . UNIT C101 5 . THE CONTRACTOR SHALL MAINTAIN THE EXISTING STRUCTURAL AND FIREPROOFING INTEGRITY THROUGHOUT THE EXT. EXTERIOR STRUCT. STRUCTURE TYPICAL SYMBOL DESIGNATIONS. EDWARDS, COLORAD081632 AREA CHANGED TO B OCCUPANCY AS NO PATIENT CARE WILL BE PROVIDED IN THIS AREA ENTIRE PROJECT AREA. PROVIDE ELECTROLYSIS PROTECTION BETWEEN ALL DISSIMILAR METALS, WHERE THEY EXIST. EXISTING SUSP . SUSPENDED MAY NOT BE USED IN THE DRAWINGS. 970.926.8960 F.970.926.8961 OCCUR. E EXISTING • OF THE BUILDING. NUCLEAR MEDICINE IS AN OUT- PATIENT IMAGING SERVICE. THE � � STERILE PROCESSING COLLECTION RECEIVES SOILED INSTRUMENTS, CLEANS AND FD. FLOOR DRAIN TREAT. TREATMENT 4�_ OIMENSION LINE 6. THE OWNER SHALL BE CONTACTED IN REGARDS TO ANY SALVAGEABLE MATERIAL OR EQUIPMENT. ANY �� REPACKAGES INSTRUMENTS FOR PROCEDURES DELIVERED THROUGHOUT THE BUILDING VIA SALVAGEABLE ITEMS NOT TO BE REUSED OR WANTED BY OWNER SHALL BECOME PROPERN OF THE CONTRACTOR. GA. GAUGE U . C . L. _ _ UNDER CABINET LIGHT CARTS. AS SPC IS A WASTE COLLECTION AREA GREATER THEN 100 SQUARE FEET. THE GALV. GALVANIZED U . N .O. UNLESS NOTED OTHERWISE INCIDENTAL USE AREA REQUIRES A 1 HR SEPARATION , OR FIRE EXTINGUISHING sYSTEM . APPROVED THE BUILDING IS FULLY PROTECTED, BUT THE LIFE SAFETY CODE DOES NOT ALLOW THIS 7 . CONTRACTOR SHALL PROVIDE ADEQUATE BLOCKING IN WALLS TO RECEIVE ALL ATTACHED EQUIPMENT, GL. GLASS V. I . F. VERIFY IN FIELD EXCEPTION . STERILIZERS ARE ACCESSED ON SPC SIDE AND SERVICED ON STERILIZER _. i Commun'�tyDevetOpmentDepartment PLUMBING FIXTURES , MILLWORK, CASEWORK , ETC . NOTE: ALL FRAMING OR CONCEALED BLOCKING SHALL BE 20 GYP . BD. GYPSUM BOARD VCT. VINYL COMPOSITION TILE • Buiiding Safetyend Inspection Services ._._._ . ,. ,_ __-.-_.._.._._._.-._-_-. SIDE. THRU WALL PENETRATIONS WILL NOT BE SEALED TO MEET 1 HR RATING, SO AREA GAUGE SHEET METAL. ' ---" ' -' � WALL NPE TAG TO{YNOF VAfI. G .C. GENERAL CONTRACTOR W WITH IS INCLUDED IN THE 1 HR ENCLOSURE FOR SPC. THE CART WASH WILL BE USED TO HGT. HEIGHT WB . WOOD BASE CLEAN CARTS PRIOR TO RESUPPLYING THEM WITH STERILE INSTRUMENTS. Section ' �' ' ` 8 . PROVIDE SEALANT AROUND ALL PLUMBING FIXTURES WHERE THEY ABUT ADJACENT SURFACE. :'c:'� . Intematlonal Building Code/Intemational Fe�'.'. :- :lc! H . M . HOLLOW METAL WD. WOOD Code V�:iCi'y ci permit The issuance orgranting of e Forc ' 9 . CONTRACTOR SHALL PATCH AND REPAIR WALLS , FLOOR AND CEILING AS REQUIRED FOLLOWING DEMOLITION OF not be c.-:' '.:�d ,o be a permit tor, or an approval ct, c^y ' `. ^ �f EXISTING PARTITIONS AND EXISTING FINISHES. r 2 3 an �' c� ofth � codeorcfanyotherodin r� � 0.0 ABBREVIATIONS NPICAL ABBREVIATIONS. MAY NOT BE USED IN THE DRAWINGS. 00 SYMBOLS p,p BUILDING CODE INFORMATION jun� i � pres Fngtogiveau;hon,ytowelaec � ci �he 10. ANY MISCELLANEOUS ITEMS OR MATERIALS NOT SPECIFICALLY NOTED , BUT REQUIRED FOR THE PROPER P��� , crc ro � n r e �ft ;.. ' , � rE -� , � . � c. � ��' c ' , and EXECUTION OR INSTALLATION , OR PERFORMANCE OF THE WORK, SHALL BE PROVIDED BY THE CONTRACTOR. THE othe . � � - � - � ` CONTRACTOR SHALL PERFORM HIGH QUALITY, PROFESSIONAL WORK. MATERIALS SHALL BE JOINED IN A MANNER 1 . ALL FINISH SAMPLES TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO ORDERING. CONTRACTOR TO co t ' . c ' " � � c:.tc. The TO PROVIDE A UNIFORM , ACCURATE FIT; WITH NEAT STRAIGHT LINES, FREE OF SMEARS OR OVERLAPS. INSTA�L VERIFY AVAIIABILITY AND STOCK OF MATERIALS AND ALLOW ENOUGH TIME TO RECEIVED GOODS FOR INSTALLATION �WN� VAIL VALLEY MEDICAL CENTER b��,,, - � f-� _ c, �sc cf a EXPOSED MATERIALS APPROPRIATELY LEVEL, PLUMB, AND AT ACCURATE ANGLES , OR FLUSH WITH ADJOINING 181 WEST MEADOW DRIVE struc.� ^ ' � V� r r �.'�ancesot TO OCCUR AT REQUIRED TIMES. ` - - , c� f MATERIALS . 2. CONTRACTOR SHALL PATCH AND REPAIR EXISTING WALLS , FLOORS AND CEILINGS AS REQUIRED FOLLOWING VAIL, COLORADO 81657 thisj r:,.� ^.I `� •<- 1 • \�_ c - ;• . DEMOLITION OF EXISTING PARTITIONS AND EXISTING FINISHES. PATCHED AREAS SHALL BE UNDETECTABLE. � CONTACT: DARRYL FLORES (970) 479 - 7119 pLANSEXAMiNnR: .�'" DATE: 1 1 . WHERE PLUMBING FIXTURES, PIPING, MEDICAL GASES, ELECTRICAL FIXTURES, MECHANICAL EQUIPMENT, OR ANY 3. WHERE NEW PARTITIONS ADJOIN EXISTING BUILDING PARTITIONS, THE NEW PARTITION FINISH SHALL ALIGN WITH . RYAN MAGILL (970) 904-0066 . ' OTHER EQUIPMENT IS REMOVED, ALL PIPING AND/OR CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF EXISTING FINISH . ""° ---- -- --- ----��--�-�-�- ----- � BELOW THE FLOOR INSIDE WALLS OR ABOVE CEILINGS AS APPROPRIATE. FINISHED SURFACES OF NEW WORK MEETING EXISTING CONSTRUCTION OF SIMILAR MATERIALS IN THE SAME PLANE ARCHITECT DAVIS PARTNERSHIP, P�C� CATORRUMA & ASSOCIATES, CO. SHALL BE FLUSH WITH NO VISIBLE JOINT SHOWING. WHENEVER EXISTING FINISH MATERIAL AND/ OR SURFACES 0225 MAIN ST. , UNIT Ct 01 1550 DOVER STREET, SUITE 2 12 . CONTRACTOR SHALL VISIT THE SITE AND BECOME COMPLETELY FAMILIAR WITH ALL EXISTING CONDITIONS PRIOR MUST BE CUT OR OPENED , THIS IS TO BE REPAIRED AND RESTORED SO THAT THE FINISHED PATCH IS TYPICAL WALL TYPE "'m EDWARDS, COLORADO 81 632 LAKEWOOD, CO 80215 TO SUBMITTING PRICES AND STARTING WORK . THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY UNDETECTAB�E AND MATCHES ADJOINING AND ORIGINAL WORK IN EVERY WAY. 3 �" METAL STUDS AT 16" O .C . WITH 1 LAYER �" GYPSUM BOARD, BOTH SIDES CONTACT: SCOTT NEVIN , AIA (970) 926- 8960 CONDITIONS OR DISCREPANCIES ADVERSELY AFFECTING THE DESIGN INSTALLATION PRIOR TO PROCEEDING WITH THE 4. WHERE CONSTRUCTION HAS DISRUPTED THE EXISTING WALLS, FLOORS, CEILINGS, ETC . THE FOLLOWING SHALL EXTEND WALLS 6" ABOVE FINISHED CEILING U . N .O . CHERYL DORNAK, AIA (970) 926 -8960 WORK (INCLUDING CONFLICTS WITH MECHANICAL DUCTS, STRUCTURE, PIPING, CONDUIT RUNS , MECHANICAL UNITS , OCCUR: _. ISSUE/REVISION DATE NO. LIGHT FIXTURES, CEILING FEATURES OF FLOOR BELOW, FIRE SPRINKLERS LINES OR HEADS, ETC. ) WHETHER A. WHERE WA�LS HAVE BEEN REPAIRED AND PATCHED, THE ENTIRE WALL IS TO BE REPAINTED, SO THAT THE MECHANICAL / ELECTRICAL CATOR, RUMA 8 ASS�CIATES, C0� EXISTING OR NEW. PATCH IS UNDETECTABLE ACROSS THE ENTIRE WALL SURFACE. ENGINEER 1550 DOVER STREET SUITE 2 TOV CODE REVIEW 1JUNE07 B. WHERE WALL BASE HAS BEEN REPAIRED AND PATCHED, NEW BASE TO MATCH EXISTING SHALL INFILL 2 '-6 " IN LAKEWOOD, COLORADO 80215-3132 13. GENERAL CONTRACTOR TO CLEAN ANY EXISTING WINDOW TREATMENTS , FLOOR FINISHES, AND CASEWORK THAT EITHER DIRECTION OF THE PATCH AND REPAIR (5' -0" LINEAR FEET TOTAL) TO MAKE THE PATCH UNDETECTABLE. � CONTACT: ELECTRICAL - KAY BATHKE 303) 232- 6200 ARE TO REMAIN . C . WHERE FLOOR HAS BEEN REPAIRED AND PATCHED , NEW CARPET, VCT, VINYL SEAMLESS FLOORING AND/OR ` ' ' ` " ' � � TILE TO MATCH EXISTING SHALL INFILL 3' - 0 " IN ANY DIRECTION OF THE PATCH AND REPAIR (9 ' -0" SQUARE FEET ,,,,m MECHANICAL - MICHAEL JOHNSON (303) 232 - 6200 14. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND ENGINEERING TOTAL) TO MAKE THE PATCH UNDETECTABLE. � DRAWINGS, SPECIFICATIONS , OR EXISTING CONDITIONS . D.WHERE CEILING HAS BEEN REPAIRED AND PATCHED NEW CEILING GRID , ACOUSTICAL CEILING TILE, AND OR �y' �• - � CONTRACTOR TO BE DETERMINED � 15. CONTRACTOR TO CHECK BUILDING OWNERS STOCK FOR THE REUSE OF CONSTRUCTION ITEMS INCLUDING; GYPSUM BOARD TO MATCH EXISTING SHALL INFILL 2' -0" IN ANY DIRECTION OF THE PATCH AND REPAIR (4' -0" WALL TYPE 1 "'° DOORS / HARDWARE / SINKS, ETC. DURING BID PHASE. IF ITEMS ARE TO BE REUSED, SUBMIT LIST AND SQUARE FEET TOTAL) TO MAKE THE PATCH UNDETECTABLE. IF CEILING GRID AND/ OR TILES ARE TO BE 1 HOUR RATED WALL - UL DESIGN N0. U465 CONDITION TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATION/INSTALLATION . REPLACED, THEY SHALL BE REPLACED IN WHOLE INCREMENTS, SO AS TO MAKE THE PATCH UNDETECTABLE. WHERE GYPSUM BOARD CEILINGS ARE PATCHED AND REPAIRED, THE ENTIRE CEILING IS TO BE REPAINTED , SO 16. CONTRACTOR TO SCHEDULE A CHALK WALK WITH THE ARCHITECT AND OWNER. CONTRACTOR TO INFORM THAT THE PATCH IS UNDETECTABLE ACROSS THE ENTIRE CEILING PLANE. 3 �" 25 GA. STEEL STUDS AT 24" O.C . WITH 1 LAYER �" TYPE 'X' GYPSUM BOARD, BOTH SIDES. EXTEND GYPSUM ARCHITECT AND OWNER OF ANY DEVIATIONS FROM PROPOSED ROOM SIZE OR CEILING HEIGHT FOR APPROVAL BY 5. ALL VERTICAL DIMENSIONS SHOWN TO FLOOR ARE TO BE FINISHED FLOOR, UNLESS NOTED OTHERWISE. BOARD FROM FLOOR TIGHT TO DECK OR STRUCTURE ABOVE. OWNER . CONTRACTOR TO SCHEDULE AN ELECTRICAL BOX WALK WITH THE ARCHITECT OWNER. CONTRACTOR TO WHERE FINISH IS TO BE CARPET, VERTICAL DIMENSION IS TO SIAB. SCHEDULE A FINAL PUNCH WALK WITH THE ARCHITECT AND OWNER . IF MORE THEN ONE PUNCH LIST WALK THRU 6. WHERE EXISTING WORK IS TO REMAIN AND BE REPAINTED , PATCH AND REPAIR AS REQUIRED , SO THAT ALL IS REQUIRED, CONTRACTOR IS TO COMPENSATE FOR ARCHITECT'S AND ENGINEER 'S EXPENSES . PATCHED AREAS ARE UNDETECTABLE. NEW WORK THAT ADJOINS EXISTING SURFACES SHALL BE FLUSH , TRUE, PLUMB AND/OR IN SAME PLANE AS THE EXISTING WORK AND FINISHED TO BLEND AND MATCH IN TEXTURE AND "'°° FINISH WITH ADJAC NT SURFACES. FLOAT PATCH S AND JOINTS A MINIMUM OF 24" WIDE TO BLEND. 17. THE PRESENCE OF THE ARCHITECT OR REPRESENTATIVE ON THE JOB SITE DOES NOT IMPLY CONCURRENCE E E OR APPROVAL OF THE WORK , THE CONTRACTOR SHALL CALL SPECIFIC ITEMS IN WRITING TO THE ATTENTION OF 7 • CONTRACTOR SHALL TAKE CARE TO PROTECT ALL NEWLY INSTALLED MATERIALS AND FINISHES UNTIL WORK IS ������ . � THE ARCHITECT TO OBTAIN THE ARCHITECT'S APPROVAL. NO CHANGES TO THE CONTRACT CAN BE MADE WITHOUT FORMALLY ACCEPTED BY THE ARCHITECT AND OWNER. DAMAGED ITEMS OR FINISHES ARE TO BE REPAIRED OR `�' REPLACED , AS REQUIRED BY THE ARCHITECT. � THE OWNER'S CONTACT, AS LISTED ABOVE, WRITTEN APPROVAL. 8. ALL FLOOR TRANSITIONS TO OCCUR AT THE CENTERLINE OF THE DOOR UNLESS OTHERWISE NOTED. FLOOR ,,,,, CO� Q TRANSITION STRIPS SHALL BE SUBMITTED TO ARCHITECT FOR COLOR SELECTION . FLOOR TRANSITIONS REQUIRED WALL TYPE 2 e4 !G 18. THE CONTRACT DOCUMENTS ARE THE RESPONSIBILITY OF ALL TRADES IN THEIR ENTIRETY. WHERE AT ALL CHANGES IN FLOOR MATERIALS . NON RATED p ,p PARTICIPANTS �O REQUIREMENTS ARE SHOWN IN ONE SECTION OF THE SPECIFICATIONS OR DRAWINGS BUT NOT ANOTHER, THE g , ALL METAL ACCESS DOORS, ELECTRICAL PANELS, FIRE EXTINGUISHER CABINETS, ETC . , TO BE PAINTED TO �� CONTRACTOR OR SUBCONTRACTOR IS NOT RELIEVED FROM PROVIDING COMPLETELY FINISHED AND PROPERLY MATCH ADJACENT WqLL OR CEIILING COLOR. 3 �" 25 GA. STEEL STUDS AT 24" O. C . WITH 1 LAYER �" GYPSUM BOARD ON EACH SIDE OF STUD EXTENDED TO SCOTT M�CHAE� FUNCTIONING SYSTEMS. 10. EXTEND EXISTING FINISH AS REQUIRED WHERE DEMOLITION HAS REMOVED FINISH . INFILL FLUSH AND MATCH STRUCTURE ABOVE. SHEET � SHEET NAME REV. � OATE * NEVIN * 19 . ALL WORK UNDER THIS CONTRACT TO BE IN STRICT ACCORDANCE WITH REGULATIONS FOR CONTRACTORS EXISTING UNLESS NOTED OTHERWISE. __ __ _ ' 2p2985 /. PERFORMING WORK AT THE HOSPITAL AS FOLLOWS : 11 . HINGES TO BE HEAVY DUTY, BALL BEARING, 4- 1 /2 "x4- 1 /2", 3 PER LEAF FOR DOORS 7 ' -0" HIGH AND --- ---- ---- ----- - � � - -�- - ----- -- �i V A. PROVIDE OWNER WITH LIST OF ALL SUBCONTRACTORS, CONTACTS AND TELEPHONE NUMBERS . LESS. HINGES TO BE STAINLESS STEEL, WITH FLAT BUTTON TIPS. ARCHITECTURAL_ _... , ., , , _,_ _ _ ... . . .... . ... _ ._.._._ ,__ __ __ G�� � B . CONSTRUCTION HOURS ARE 7:00 AM TO 5:00 PM , MONDAY THROUGH FRIDAY UNLESS OTHERWISE APPROVED 12 . ALL HARDWARE TO BE LEVER TYPE TO MEETS ADA GUIDELINES . _ A0.0 ___� GENERAL INFORMATION __ _...... _...__.-__ N`sEDARG� + -� BY THE OWNER, WITH AT LEAST 48 HOURS ADVANCE NOTICE. 13. DOOR FINISHES TO BE RED OAK. DOORS TO BE FLUSH DESIGN , 1 - 3/4" THICK , SEAMLESS FACE AND EDGE A0,1 SPECIFICATIONS __.__. _ . __._. _. ___ �) �'" � C . CONTRACTOR IS RESPONSIBLE FOR BAGGING ALL SMOKE DEfECTORS AND IS RESPONSIBLE FOR ANY COSTS CONSTRUCTION . ARl, I LIFE SAFETY PLAN-OCCUPANCY & SEPARATIONS 14. ALL WOOD DOORS & WELDED FRAMES WITHIN THE WORK AREA TO BE PAINTED . - -- � -- INCURRED FROM DAMAGE TO ALARMS DUE TO DUST OR ANY OTHER CONSTRUCTION ACTIVITY. AR1,2 LIFE SAFETY PLAN- EGRESS D . ANY WORK ON THE FIRE PROTECTION SYSTEM OR FIRE ALARM SYSTEM MUST BE COORDINATED THROUGH THE 15. HOLLOW METAL FRAMES TO MEEf SDI (STEEL DOOR INSTITUTE) REQUIREMENTS , INCLUDING SDI - 105-91 AND ---- """ -"'" -----� OWNER AND LOCAL FIRE DEPARTMENT. SDI - 100 -91 . A10 DEMOLITION, FLOOR , REFLECTED CEILING PLANS --- __.._ _ __._ ..._ _ _...-------- E. CONTRACTOR SHALL NOT SHUT OFF OR PUT OUT OF SERVICE ANY SYSTEM/SERVICES WITHOUT FIRST 16. REFER TO FLOOR PLAN FOR LOCATION OF FIRE EXTINGUISHER CABINET. PROVIDE FULLY RECESSED , A20 SCHEDULES , DETAILS , AND INTERIOR ELEVATIONS �� .� -- _ .. __. _ _ ... . . COORDINATING WITH THE OWNER AT LEAST 72 HOURS IN ADVANCE . ENAMELED STEEL CABINET WITH SOLID DOOR WITH RED, VERTICAL, VINYL LETTERS . OWNER TO PROVIDE FIRE -.-. . . . .. ... . . . . . ,,, ..- - -- . - .. ., _.,, ..-----. . ,., . -.----- - �, , Q _._ . _ EXTINUISHER . UL- RATED 2-A: 10 - B:C , 5 - LB. MECHANICAL ; S / - __..... _. _....._. Q 20 . DIMENSIONS OF AND FROM EXISTING CONDITIONS HAVE BEEN TAKEN FROM EXISTING DRAWINGS AND OR FIELD M1 ,01 MECHANICAL LEGEN AND SCHEDULES_ ______ -� -- -�--- -- -- MEASUREMENTS . THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PERTAINING TO EXISTING CONDITIONS M1 ,02 SPECIFICATIONS � � PRIOR TO THE START OF CONSTRUCTION . M3,01 i PARTIAL FIRST FLOOR HVAC PLANS � ---- ------ 21 . DIMENSIONS LOCATING NEW CONSTRUCTION ARE TO FINISHED FACE UNLESS NOTED OTHERWISE. DIMENSIONS M4.01 PARTIAL FIRST FLOOR PIPING PLANS __ . i � � _.... . . LOCATING EXISTING CONSTRUCTION ARE FROM EXTERIOR FINISHED SURFACE UNLESS NOTED OTHERWISE. M5,00 ; PARTIAL FIRST FLOOR PLUMBING PLANS SANITARY WASTE I V A � � M5.01 PARTIAL FIRST FLOOR PLUMBING PLANS � � - - .. _.__. - . . . - ---.-..----- - 22 . NOTIFY ARCHITECT OF ANY DISCREPANCIES UNCOVERED BY DEMOLITION ; OR IF EXISTING CONDITIONS PREVENT M6,01 PARTIAL SEC�ND FL� �R ENLARGED MECH PLANS _ -- - LAYOUT FROM PROVIDING PROPER CLEARANCES . M602 PARTIAL SEC�ND FLO�R_ ENLARGED MECH PIPING PLANS Valley _ --._ _._...- - --- 23 . DOOR ASSEMBLIES IN INTERIOR PARTITIONS ARE 6 " FROM FINISHED FACE OF ADJACENT PARTITION TO THE M701__._ ___ GAS PIPING. . DIAGRAM ( ) --------.....__..-._ - - --- __- .._ r .. • EDGE OF THE DOOR LEAF UNLESS NOTED OTHERWISE. 1 . PROVIDE SOUND ATTENUATION BATTS IN ALL NEW WALLS TYPICAL . ELECTRICAL ---- , -- ---- - - - -. _ _ _ Med � cal 24. CONTRACTOR TO REPAIR ANY DAMAGE FROM REMOVING EXISTING FINISHES OR WALLS TO INSURE THAT _._ElAl _ ELECTRICAL LEGENDS SCHEDULES AND SPECS 2. REFER TO A2.0 FOR SLIP HEAD DETAIL AT RATED WALL. i SURFACE IS SMOOTH AND PREPPED FOR PAINTING AND WALL COVERING . PROVIDE THE MINIMAL FURRING E3,04 ELECTRICAL 1 -LINE DIAGRAM NORMAL POSSIBLE IF EXISTING WALLS OR DAMAGED WALLS CANNOT BE PROPERLY PREPARED TO RECEIVE NEW FINISH . �� ----- - -- E3.05 ELECTRICAL 1 -LINE DIAGRAM EMERGENCY Center --.._ --- �-- ., .. _.-. 25. CONTRACTOR TO ACCESS EXISTING CONDITIONS AND RESTORE ALL RATED PARTITIONS AND ASSEMBLIES AS E401 PARTIAL FIRST FLOOR LIGHTING AND POWER & SYSTEMS PLAN REQUIRED. . -. E6 O1_, _ ELECTRICAL,,._DETAILS__AN.D_PANEL SCHEDULES,, ___ ._ ._ __ ., ,.. ... . . ._ . .. ._.. _ --- o. o GENERAL NOTES o,a INTERIOR FINISH NOTES o.o WALL TYPES o.a DRAWING INDEX o6�.1 3 � ��, �-°�j �---� INDICATES EXISTING WALLS OR O INDICATES EXSITING WALL ��;� � PARTITIONS TO REMAIN D1 EXISTING CASEWORK TO BE REMOVED INDICATES NEW 2 ' x4' CEILING GRID WITH NEW �; I �� �� A � ACOUSTICAL CEILING TILE/ACT i �- wES* vni� i :° -� �� INDICATES EXISTING DOORS INDICATES NEW WALL I 1 r } r ' TO REMAIN D2 EXISTING SHELVING AND FRAMING INSET TO BE REMOVED SITE LOCATION i _ r_ � FII Sl FIOOI i 1 v- INDICATES NEW DOOR NORTH �I' � � Nuclear Medicine � � INDICATES EXISTING WALLS OR D3 EXISTING SOFFIT TO BE REMOVED I ii I PARTITIONS TO BE REMOVED CONTRACTOR TO COORDINATE REMOVE OF FLOOR FINISH INDICATES EXSITING DOOR i i� SPC Remodel � � INDICATES EXISTING DOORS AND D4 WITH NEW CONSTRUCTION BETWEEN TWO POINTS. BASE TO � ` INDICATES GYPSUM BOARD CEILING OR SOFFIT Msw vni� Exir DOOR HARDWARE TO BE REMOVED '' � � �" � ,'� ' ';, "�` BE REMOVED AND WALLS PREPPED FOR PAINT. � � O ` �T, c`^ ^ � ^c ^ T � cn �� INDICATES NEW 2 'x4' RECESSED fNT � � � D .� X; .. � � NG �CRIN � , 3AS" � �IUN � 0 B� RENOV�� . � O � FL'u0Rc5CctiT i iXTuRE �'l;'yy' � � � INDICATES EXSITING GYPSUM BOARD CEILING sourH AT�' H� 181 W . Meadow Drive I � � ��I. OR SOFFIT � WEST FR�NTAGE ROAD cy�9y > EAST VAIL INDICATES NEW 2 'x2' RECESSED ��� � M o -� 1 . WHEREVER PLUMBING FIXTURES, PIPING, ELECTRICAL FIXTURES & MECHANICAL EQUIPMENT IS REMOVED, ALL O FLUORESCENT FIXTURE \ �oRE ADpw R > '" PIPING AND/OR CONDUITS THAT ARE ABANDONED SHALL BE CAPPED OFF BELOW THE FLOOR, UNLESS NOTED � ciRC�E = E � �ST a -R VCaII , Colorado OTHERWISE. ELECTRICAL AND MECHANICAL ITEMS TO BE REMOVED ARE DEFINED ON THE E & M SERIES OF � INDICATES INCANDESCENT DOWNLIGHT �P � CRE�K' � �ASj MEA°°W oRive ME"AUp ' d - _ - - ro DRAWINGS . CONTRACTOR TO COORDINATE PROPOSED RELOCATED ITEMS WITH OWNER AND ARCHITECT PRIOR TO w ��- =- � `" °a,vE • ,. - - ' INSTALLATION . <' \ wi��ow � ' � 81657 2 . CONTRACTOR TO CAREFULLY REVIEW AND ASSESS THE VARIOUS SLAB CONDITIONS AND COORDINATE FLOOR � 9� INDICATES UNDER CABINET UGHT m eEAVER ar Roqo o � eRioce ` CORE ; - � ,� - _ „p • • � ❑ .-�.._....-- -^.. PATCHING AND ADDITIONAL PREPARATION WITH FINISH TO BE INSTALLED. \ g / � Rano = W _ �3f, ' _ - � a _ 3 . REVIEW DEMOLITION OF AND PENETRATIONS THROUGH EXISTING STRUCTURE WITH STRUCTURAL ENGINEER WHERE INDICATES SURFACE MOUNTED � _ %' � = a \� �:. � `\ ��� - - - 4 � --• -�-�. '� POTENTIAL OF ENCOUNTERING BEARING MEMBERS OR REINFORCEMENT EXISTS. NOTIFY ARCHITECT IF EXISTING � � " ' ' ' . - � � FLUORESCENT FIXTURE � wi��ow �oRE _ro. �aF � ,� RonD \ •- : . .r- r - ASSEMBLIES DESIGNATED AS RATED REQUIRE MODIFICATION . 1 RoAO - FaResr Roq wi��ow P��E I -- - � - - ' • � ' l - � 4 . THE GENERAL CONTRACTOR IS TO COORDINATE ALL WELDING VENTING, AND TIMES OF DEMOLITION AND FoRES ° Roq 1 � ys� � @ '� w � _ CONSTRUCTION WITH THE OWNER AND CONCURRENT OCCUPANCY OF THE BUILDING. � \HAN oh R\/o'Pa `�' ' • _ ' - ' 5 . C O N T R A C T O R T O C A R E F U L L Y R E V I E W A N D A S S E S S T H E V A R I O U S S L A B C O N D I T I O N S A N D C O O R D I N A T E F L O O R RO�K�E pc �N ti � o - - PATCHING AND ADDITIONAL PREPARATION WITH FINISH TO BE INSTALLED . RCP NOTES: E Raq A'< vn��Er o ' °' R � � ' ' ' • • .,, 'm 6 . FIELD LOCATE ALL UTILITIES UNDER NEW CONSTRUCTION PRIOR TO EXCAVATION AND RELOCATE AS REQUIRED. 1 . CEILING HEIGHT TO BE 8' -0 " A. F. F. UNLESS NOTED OTHERWISE. NOTIFY ARCHITECT IF HEIGHT IS � �� ' � ' ' ' ' ' � ' GET OWNER APPROVAL BEFORE RELOCATION . UNACHIEVABLE. _ _� �i� _ - � • 6„ ! . ,�J; ' � � ! r 7 . GENERAL CONTRACTOR SHALL CAREFULLY REMOVE AND INVENTORY ALL ITEMS OF SALVAGEABLE VALUE PRIOR i'� � _ � = . , . GENERAL INFORMATION _ � .� TO BEGINNING CONTRUCTION . THESE ITEMS INCLUDE, BUT ARE NOT NECESSARILY UMITED T0: 2 . REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF LIGHT FIXTURES, REFER TO ELECTRICAL DRAWINGS FOR � �� �Re _ _ _ ' � - LIGHT FIXTURES FIXTURE SIZES AND TYPES, EXIT SIGNS, SPEAKERS SMOKE DETECTORS AND ADA REQUIRED DEVICES . ��RC�F fk__ �, '� '+' Y � _ __� _ - - LIGHT SWITCHES " Y 1 �- - THERMOSTATS 3 . REFER TO MECHANICAL DRAWINGS FOR GRILLE SIZES. � ❑ ' ' - DOORS - DOOR HARDWARE 4, SPRINKLER HEADS TO BE CENTERED IN TILE. m m m 0 0 p � � � o DATE 2 APRIL 2007 - FIRE EXTINGUISHERS (INCLUSIVE OF CABINET) DRAWN BY CD - PLUMBING FIXTURES AND FAUCETS 5. CENTER GRID IN ROOM / HALL WAY. - EXHAUST FANS - TOILET ROOM ACCESSORIES CHK ' D BY SN ANY ITEM BEING RE- USED IN NEW CONSTRUCTION SHALL BE CLEANED AND TESTED (WHEN APPLICABLE) PRIOR TO PROJECT SCOPE MODEL FILE AO-O.dwg REINSTALLATION . OF WORK 8 . CONTRACTOR TO PROVIDE AND MAINTAIN ADEQUATE PROTECTION OF ALL ITEMS AND FINISHES THAT ARE TO CAPYRIGMT 2007 6Y DAVIS PAR7NERSHIP P.C., AftCHITEC75 REMAIN FOR THE DURATION OF THE PROJECT. DAMAGED ITEMS OR FINISHES ARE TO BE REPAIRED OR REPLACED BY THE CONTRACTOR AT NO COST TO THE OWNER. sr+eEr NuMeeR: A0 . 0 o.o DEMOLITION NOTES AND PLAN LEGEND oo REFLECTED CEILLING PLAN LEGEND o'o VICINITY MAP oo KEY PLAN D . P.A. PROJECT # 06938 .00 GENERAL REQUIREMENTS s� mmary otwor�: Interior Architectural Woodwork : Acoustical Panel Ceilings : The work consists of interior renovation with mechanical and electrical work, as described in the Contract Documents. Submit Shop Drawings and Samples specified. Submittal to include fastening/assembly Submit Product Data and Material Samples. methods, locations, dimensions, finishes and rough-in for M&E devices. Acoustical Panel Ceilings: Comply with ASTM E 1264 for Class A materials, as determined by testing identical products per ASTM E 84. Contractor's Use of Premises: Quality Standard: Architectural Woodwork Institute's "Architectural Woodwork Quality Standards." Materials: Ceiling tile and grid are new. ' . During construction, Contractor shall have limited use of space indicated. Contractor's use of premises is limited only by Owner's right to perform work or employ other AWI Type of Cabinet Construction: Flush overlay. WIC Construction Style: Style A, Frameless. WIC Door and Drawer Front Sryle: Flush overlay. Ceiling Suspension Systems: contractors on portions of project. Gaps between doors/drawers to be equal and orthogonal. Direct-hung suspension system, with intermediate-duty structural classification according to ASTM C 635. � � � � Arch i t ls Size attachment devices for 5 times the design load indicated in ASTM C 635, Table 1 , Direct Hung, unless othervvise indicated.ce Materials: PaYment Procedures: Zinc-coated carbon-steel wire hangers, braces, and ties complying with ASTM A 641 (ASTM A 641 M), Class 1 zinc coating, soft temper. Hardboard: AHA A135.4 Submit a Schedule of Vaiues which breaks down the Contract Sum into at least one line item for each technical Specification Heading. Correlate the Schedule of Values Installation: Medium-Density Fiberboard: ANSI A208.2 CISCA's "Ceilin " with the Contractor's Construction Schedule. g Systems Handbook. Particleboard: ANSI A208. 1 , Grade M-2 CISCA's "Recommendations for Direct-Hun Acoustical Tile and La in Panel Ceilin s Submit 3 notarized copies of each Application for Payment on AIA Document G702/703, in accordance with the schedule established in the Agreement. Hardwood Plywood and Face Veneers: HPVA HP-1 9 Y 9 '� For the Application submitted at Substantial Completion, submit partial releases of liens from each subcontractor or supplier for whom amounts were requisitioned on the High-Pressure Laminate Grade: Grade 51 -General Purpose (HGS , nominal thickness 0.050"/1 .2mm). ASTM C 636, "Standard for Ceiling Suspension System Installations."oject. U . B.C. Standard 47-18. previous payment. Edge Treatment: PVC edges if match available for counter laminate: refer to drawings and cut on cabinet surfaces. 2301 BLAKE ST., STE. #100 Manufacturer: Armstrong Ceilings Countertops: Plastic Laminate by Wilsonart Laminate or equal. .048" thick. ACT-1 : Armstrong square lay-iN , Clean Room VL 24"x48"x3/4", with 15/16" prelude xl exposed tee system grid. 3�3N 6E 8 55 �03 86183027 Coordination: Cabinet Interiors: White Melamine. Pro ress meetin s will be held at Pro'ect site eve two 2 weeks. Owner, Architect, Contractor and each subcontractor or other entit concemed with current ro ress or Contact Adhesive: Provide Laminate manufacturer recommendation for the application. 9 9 1 rY � ) Y P 9 0225 MAIN STREET . UNIT C101 involved with planning or coordination of future activities, shall attend. Minutes of each meeting will be prepared by Contractor and distributed to all parties present. Plastic laminate to be applied to all exposed surfaces unless otherwise noted. Caulk all joints where casework meets wall. Seam fill all joints at underside of upper Concrete Toppings : EDWARDS, COLORADO 81632 Contractor to provide progress schedule at each OAC meeting indicating project work for the next three weeks. cabinets. Provide self-leveling underlayments complying with the requirements of ASTM C94 over existing base slab so as to provide a smooth and level surface to 970.926.8960 F.970.926.8961 Casework to be installed level. Underside of upper cabinets to be installed at fller pieces, corners, and panels. receive finished flooring materials. Remove dirt, loose material, oil , grease, paint or other contaminants from existing concrete slab leaving a clean surface Submittal Procedures: to receive topping slab. Repair all cracks in existing concrete floor slab to minimize telegraphing. Prime existing floors in accordance with he requirements Coordinate submittal preparation with construction schedule, fabrication lead-times, other submittals and activities that require sequential operations. CBI�IC1@t H8t'CJWBf@ 811CI ACC@SSO�I@S : of the manufacturer. Trowel floor to produce a finished surface free of trowel marks, uniform in texture and appearance and achieving the following No extension of Contract Time wi�l be authorized due to failure to transmit submittals in time to permit processing sufficiently in advance of when materials are required in the Hinges: Blum 706500 F5 FO or equal; Mounting Plate 175H7100 or equal tolerances when tested in accordance with ASTM E 1155. Work. Pulls: 4" Brushed Wire pulls. Ives by Schlage, No. 137 US32D or equal. Manufacturer: Ardex, Inc. Prepare submittals by placing a permanent label on each for identification. Provide label to record review and approval markings and action taken. Include the following Drawer guides: Blum 320 M & Blum 125 degree opening or equal . Locks: Disc Tumbler Cylinder Cam Locks. National Cam Locks or equal. information on the label : Exposed Hardware Finishes: For exposed hardware, provide finish that complies with BHMA A156.a8; provide BHMA 619IUS 15, BHMA 626lUS 26D , BHMA 625IUS 26, Resilient Wall Base and Accessories : Project Name or BHMA630/US 32D; unless noted otherwise. Date Furring , Blocking , Shims and Hanging Strips: Flame-Retardant Softwood or hardwood lumber, kiln dried to 15 percent moisture content. Submit Product Data and Color Samples. Name and Address of Contractor At completion of project, deliver to Owner at least 10 linear feet for each 500 linear feet or fraction thereof, of each type and color of resilient wall base Name and Address of Subcontractor and Supplier Joint Sealants ' installed. Provide resilient rubber wall base and accessories as scheduled on drawings A7-2. Title of Appropriate Technical Specification Heading Submit Product Data and color Samples. Apply resilient rubber wall base to walls in SO feet lengths, columns, pilasters, casework, and other permanent fixtures in rooms or areas where base is Product Data: Submit (3) three copies and mark each copy to show applicable choices and options. Compatibility: Provide joint sealants, joint fillers, and other related materials that are compatible with one another and with joint substrates under service and application required. Form wall base corners from straight pieces. Install reducer strips at edges of flooring at dissimilar materials and exposed concrete floors. conditions. Roppe No. 177 Tile - Carpet Jointer between tile and carpet. Roppe No. 168 reducer at VCT to sheet vinyl transition. Shop Drawinps: Latex Sealant: At perimeter of door frames, plumbing fixtures and casework to walls (recess bead so that clear silicone bead can be applied on top). Pecora AC-20 one Submit newly prepared information drawn to scale. Contrector to indicate deviations from Contract Documents , including any addenda or change to the scope of the part acrylic latex caulk or equal. original scope of work. Do not reproduce Contract Documents or copy standard information. Submit 1 reproducible print and 1 blue- or black-line print on sheets at least Elastometric Sealant: Comply with ASTM C 920. TI �e : 8-1 /2 by 11 inches but no larger than 30 by 42 inches. Architect will return the reproducible print. Acrylic Sealant: One-part, non-sag, solvent-release-curing acrylic terpolymer sealant complying with AAMA 808.3 or FS TT-S-00230, or both, with capability, when tested As specified on A2.0 three sam le finishes as ifi n i nti I wi h h m ri are inherent in the materiai submit t le t hr ni per ASTM C 719, to withstand plus or minus 12.5 percent change in joint width existing at time of application without failing. Setting Materials: Hydroment "Single-Flex 916" latex modified dryset mortar and waterproof inembrane by Bostik Findley. Samples: Submit (3) p spec ed a d de ca t t e ate al proposed. Where variations a as (3) t ee u ts Ac lic-Emulsion Sealant: One- art, non-sa mildew-resistant, aintable, ac lic-emulsion sealant com I in with ASTM C 834. Existin floor to be re ed to insure flush , smooth floor. Float floor with consistent slo e to floor drains where re wred. that show limits of the variations. Provide shop drawings for the following items: Doors and Frames, Door Hardware, Casework, Casework Hardware, Casework Finishes, ry P 9' P ry p Y 9 9 P PP P 4 CATOR RUMA 8 ASSOCIATES, CO. Silicone-Emulsion Sealant: At cap strip of integral sheet vinyl floor and adjacent surface. Product complying with ASTM C 834 and , except for weight loss measured per 1550 DOVER S7REET, SUITE 2 Paint, Corner Guards. Wall Coverings, Acoustical Ceiling Tiles and Grid, Carpet, Base and VCT. Include product name or name of the manufacturer. Architect will review ASTM C 792, with ASTM C 920, that accommodates joint movement of not more than 25 percent in both extension and compression for a total of 50 percent. Dow Carpet : LAKEWOOD, CO 80215 each submittal, mark as appropriate to indicate action taken, and return copies less one retained . Any Substitution of materials requires Contractor to provide data indicating Corning 790 Silicone Building Sealant or equal. product equivalence; submittals will not be reviewed if information is not provided. Acoustical Sealant: Non-sag , paintable, non-staining, latex sealant complying with ASTM C 834. Submit Product Data and Color Samples. Acoustical Sealant for Concealed Joints: Non-drying, non-hardening, non-skinning, non-staining, gunnable, synthetic rubber sealant recommended for sealing interior Prep floor as required and install a self-leveling compound (see Concrete Topping Slab section above) to provide a flat and level finished surface. ISSUE/REVISION DATE NO. Temporarv Facilities and Controls: concealed joints to reduce transmission of airborne sound. Installer Qualifications: Engage an experienced Installer who is certified by the Floor Covering Installation Board (FCIB) or who can demonstrate Standards: Comply with NFPA 241 , "Standard or Safeguarding Construction , Alterations, and Demolition Operations; ANSI A10 Series standards for "Safety Requirements compliance with FCIB certification program requirements. TOV CODE REVIEW 1 JUNE07 Carpet that have flame-spread and smoke-developed ratings of 25 or less and 450 or less, respectively, when tested according to ASTM E 84. Comply for Construction and Demolition"; and NECA Electrical Design Library's "Temporary Electrical Facilities." Electrical service shall be in accordance with NEMA NECA and UL Hollow Metal Doors and Frames : with CRI 104, Section 6, "Site Conditions." standards and regulations for temporary electric service. Install service in compliance with NFPA 70. Submit Product Data and Door Schedule. At completion of project, deliver to Owner full-width carpet equal to 5 percent of each type and color carpet installed, packaged with protective covering for Interior poor Frames: Provide units with mitered or coped and continuously welded corners formed from 0.0478-inch thick, cold-rolled steel for openings 48 inches or less storage. Temporarv Utilities: in width and from 0.0598-inch steel for openings more than 48 inches in width . For rated doors and pairs of doors only provide "heavy duty" knock down hollow metal Provide carpet as scheduled on the Drawings. Use of the Owner's existing sanitary facilities will be permitted, so long as facilities are cleaned and maintained in a condition acceptable to the Owner. At Substantial frames at all other standard door frames. Provide one floor clip per jamb, 4 metal stud anchors per jamb. Comply with CRI 104, Section, "Direct Glue-Down." Completion, restore these facilities to the condition prevalent at the time of initial use. Prepare doors and frames to receive mortised and concealed hardware according to SDI 107. Manufacturers: Lees; match exisitng. Temporarv Controls: Comply with NAAMM's "Metal Finishes Manual for Architecture and Metal Products" for recommendations relative to applying fnishes. Maintain existing fire protection until modified system of fire-protection is in place. Factory prime all surfaces (oven dry primer one mil minimum). Vln�/I COI'Y1pOSltlOn TII@ �VCT� : Submit Product Data and Color Samples. Provide temporary barricades, warning signs, and lights to protect the public and construction personnel from construction hazards. WOOCI DOOI'S : Prep floor as required and install a self-leveling compound (see Concrete Topping Slab section above) to provide a flat and level finished surface. Submit Product Data and door schedule. Provide 1 /8 inch nominal gauge, 12 in. x 12 in. Armstrong MultiColor Tile in meeting ASTM F 1066, Class 2 - through-pattern. Colors will be selected from Product Requirements: Product: Oak with clear finish to match existing. the range currently available from Armstrong World Industries, Inc. in thickness designated. The Owner and Architect may consider substitutions of specified materials which provide a savings in Contract Sum and/or Time. The Contract Sum and Time savings shall Source limitations: Obtain flush wood doors through one source from a single manufacturer. Install tile in strict accordance with manufacturer's written instructions over approved subfloors using the Vinyl Composition Tile Installation System with be identified at time of submittal. The request for substitution shall be submitted in reasonable and timely manner for review, as not to delay construction. Substitution quafity Standard: Comply with WDMA I.S.1A-04. fufl-spread (S-89) (S-7�o) (S-75�) (S-515) Adhesive as recommended by the manufacturer. Clean , seal and wax per manufacturer's recommendations. submittals shall include product information , test data, samples (if applicable), delivery time, and cost information. If deemed acceptable by the Owner and Architect, the Factory Finish: Comply with WDMA finish requirements. Finish doors at factory. Finish: WDMA TR-6 catalyzed polyurethane. Staining: As selected from manufacturer substitution submitted may be used by the Contractor. Acceptance of the substitution by the Owner and Architect does not relieve the Contrector of responsibility in standard colors or custom color in accordance with the approved sample. Factory finished doors to be installed just prior to substantial completion. Submit Product Data and Color Samples. performance or workmanship in relation to the substitution. The required warranties of any item of construction shall not be modified by substitutions. Examination: Examine doors before hanging. Reject doors with defects prior to hanging. Proceed with installation only after unsatisfactory conditions have been corrected. Prep floor as required and install a self-leveling compound (see Concrete Topping Slab section above) to provide a flat and level fnished surface. Installation: Install doors per the manufacturers written instructions. Align all doors for uniform clearance at each edge. Restore factory finish before installation if fitting or Install in strict accordance with manufacturer's written instructions with a minimum of seams over approved subfloors using the Commercial Vinyl-Backed C �� Examination and Preparation: machining is required at project site. Adjust all doors to swing and operate freely. Installation System with (5-575) (S-240 Epoxy) Adhesive and heat-welded seams as recommended by the manufacturer. Install fillet strip at intersection � Examine substrates and conditions for compliance with manufacturer's written requirements including , but not limited to, surfaces that are sound, level and plumb; substrates Warranty: Provide full lifetime manufacturers warranty for Interior Solid Core Doors. of wall and floor; toe of strip not to extend past vertical surface; mitre inside corners. Clean, seal and wax per manufacturer's recommendations. �� within installation tolerances; surfaces that are smooth , clean and free of deleterious substances; and application conditions within environmental limits. Do not proceed with Manufacturer: Marshfield Door Systems Manufacturer: Armstrong Medintech; see Finish Schedule. O SCOTT MICHAEL installation until unsatisfactory conditions have been corrected. Prepare substrates and adjoining surfaces according to manufacturer's written instructions. * NEVIN * Access Doors and Panels : Sheet Vin I : 202985 ,� Cuttinp and Patchinp: Submit Product Data.PS y <� V Before cutting/patching existing surfaces, examine surfaces to be cut and patched and conditions under which cutting and patching is to be performed. Take corrective Steel Sheet: ASTM A 366 commercial-quality, cold-rolled steel sheet with baked-on, rust-inhibitive primer. CF� �� action before proceeding if unsafe conditions are encountered. Protect existing construction during cutting and patching to prevent damage. Temporarily cover openings Trimless, Flush Access Doors for G sum Board: Units consistin of frame, concealed ed e trim, door, hardware, and com I in with the followin re uirements: Submit Product Data and Color Samples. S � _ �A YP 9 9 P Y 9 9 q ED ARG u ' Frame: 0.0598-inch thick steel sheet. Prep floor as required and install a self-leveling compound (see Concrete Topping Slab section above) to provide a Flat and level finished surface. when not in use. Patch with durable seams that are as invisible as possible. Inspect and test patched areas to demonstrate integrity of the installation. Do not cut structural Install in strict accordance with manufacturer's written instructions with a minimum of seams over approved subfloors using the Commercial Vinyl-Backed Installation � members without rior written a roval of Architect and Structural En ineer. For atchin rovide materials whose installed erformance will e ual or sur ass that of Door: 0.047-inch thick steel sheet. P PP 9 p 9 p P Q p System with (5-575) (5-240 Epoxy) Adhesive and heat-welded seams as recommended by the manufacturer. Install fillet strip at intersection of wall and Floor; toe of strip existing materials, For exposed surfaces, provide or finish materials to visually match existing adjacent surfaces to the fullest extent possible. Concealed, Gypsum Board Edge Trim: 0.0299-inch zinc-coated or galvanized-steel sheet with face flange formed to receive joint compound. not to extend past vertical surface; mitre inside corners. Provide metal cove cap and caulk to wall. Clean, seal and wax per manufacturer�s recommendations. Hinge: Concealed spring pin or continuous type. Installation: Locks: Screwdriver-operated cam. Manufacturer: Armstrong Medintech Comply with manufacturer's written instructions for installation. Anchor each product securely in place, accurately located and aligned. Clean exposed surfaces and protect Door Hardware : from damage. If applicable, prepare surfaces for field finishing. Pal11t111g : Warranty: 5 year repair or replacement of defective components. Lifetime warranty for replacing sagging levers and cylinder housing. Submit Hardware Schedule. For fire-rated openings, provide hardware tested and listed by UL or FM (NFPA 80). On panic exit devices, provide UL or FM label indicating Submit Product Data and prepared Color Samples. Final Cleaninq: "Fire Exit Hardware." All hardware shall be ADA compliant. At completion of project, deliver to Owner a 1 -gal. (3.8-L) container, properly labeled and sealed, of each color and type of finish coat paint used on Clean each surface or item as follows before requesting inspection for certification of Substantial Completion: Door Hardware: As indicated in the Hardware Schedule on the Drawings. Non-removable hinge pins for exterior and public interior exposure. Project. � Remove labels that are not permanent. Cylinders with 6-pin tumblers. Paint: Manufacturer's first-line quality paint material of the various coating types as specified and as indicated on the finish plan. V all Clean transparent materials, including mirrors. Remove excess glazing compounds. Finishes: As specified on drawings. Comply with paint manufacturer's written instructions for surface preparation, environmental and substrate conditions, product mixing, and application. Replace chipped or broken glass. Keying: Provide 4 change keys per lock, provide 6 masters. Clean exposed finishes to a dust-free condition, free of stains, films and foreign substances. Manufacturer: Schlage Everest Restricted D Series Lever Hardware interior Paint Schedule: ♦ alley Leave concrete floors broom clean. Vacuum carpeted surfaces and wax resilient flooring. GI8ZI11g : Gvpsum Board: Submit Product Data and Samples. Comply with written instructions of glass product manufacturers; FGMAs "Glazing Manual"; and publications of AAMA, LSGA, and Wet locations: 1 coat B28W200 Pro Mar 200 Latex wall primer, 1 . 1 mils dry film thickness. M � � � C � � Architectural , Mechanical and Electrical Punchlist: SIGMA. 2 coats B62W2 series / B60VZ70 Catalyst tile clad, 4 mils per coat. Provide the Architect with a pre-punch list of items yet to be compieted prior to request for inspection. Warranty: 10 years. Mirrors: Provide beveled edge mirrors at width specifed. Non-Wet locations: 1 coat B28W400 Pro Mar 400 Latex wall primer, 2 mils dry film thickness. C � � �� � Closeout Submittals: Interior Windows and Door Lites: 1 /4" Tempered Glass 2 coats B9 Health Spec. Eg Shell, 1 .5 mils dry film thickness per coat. Record Drawings: Maintain a set of Contract Drawings as Record Drawings. Mark to show installation that varies from the Work as originally shown. Fire rated glass, "Fire-Lite" by Technical Glass Products or equal. Doors and Frames: Operation and Maintenance Data: Organize data into 3-ring binders, with pocket folders for folded sheet information. FIC@pl'OOflllg R@St01'8t10�'1 : Hollow Metal Frames: 1 coat BSOZ series Kem Kromik Universal Metal Primer, 3 mils dry film thickness per coat. Provide material matching existing damaged condition. Document compliance for use by governing jurisdiction. Provide appropriate dust control, ventilation or 2 coats 610 Health Spec semi-gloss, 1 .5 mils dry film thickness per coat. Closeout Procedures: Wood Doors: Factory Finished - Stained and Sealed Request Substantial Completion inspection once the following are complete: contamination methods. Prep substrate to assure proper bonding. Apply primer and prepare product per manufacturer's recommendations. Remove any overspray from Advise Owner of pending insurance changeover requirements. adjacent surfaces. Corner Guards : Submit Record Drawings, Maintenance Manuals, warranties and similar record information. FIP@StOpplClg : P Product Data: Submit manufacturer's roduct data. Deliver spare parts, extra stock and similar items. Document com liance that each com onent of enetration throu h rated assembl matches assembl ratin and meets or exceeds the overnin urisdiction's testin Samples: Submit 12" (304.Smm) long sample of each model and color specifed, including end caps, for ArchitecYs approval. Complete startup testing of systems. p p p 9 y y 9 9 9 � 9 requirements. Submittals to include testing agency and design number, sequence of installation, method of sealing smoke or fire transmission. Preparation of surfaces Comply with NFPA 101 for interior finish materials. Smoke developed less than 450 and flame spread of 25 or less in accordance with ASTM E 84. Remove temporary facilities and controls. should be included in the criteria for penetration of ducts, pipes or conduits through floors and rated walls. Complete final cleanup. MANUFACTURER: InPro Corporation 150 High Impact Corner Guard; mounted over continuous aluminum retainer. Exposed surfaces shall be free of F i rst F I oo r Touch up, repair, replace and restore marred, exposed finishes. Material to be non-toxic, non-corrosive, and non-combustible. Provide collar at areas susceptible to movement. wrinkling, chipping, discoloration, or other imperfections. Leg Length: 3" (50.Smm). Angle: 90°, 135°. Profile: High impact vinyl acrylic extrusion locked in Obtain final inspections from authorities having jurisdiction. place, nominal 0.078" (1 .98mm) thick. Class I/A fire rating, tested in accordance with ASTM E 84. Extrusion: Pebble grain fnish. Contains EPA registered . ob�a�� �ert�f��ate of o��UPa��y. Metal Framing and Supports : Micro-Chek antimicrobial agent. Retainer: Continuous 6063-T6 aluminum retainer along entire length of corner guard, minimum 0.060" �, .5zmm, th��k. N u cl ea r M ed i ci n e Upon receipt of a request for f nal inspection, Architect will proceed with inspection and advise the Contractor of unfilled requirements. Steel framing components for suspended and furred ceilings complying with ASTM C 645 and ASTM C 754. End Caps: Injection molded unit of color and texture similar to that of corner guard. Arrange for each installer of equipment that requires operation and maintenance to provide instruction to Owner's personnel. Wire Ties: ASTM A 641 (ASTM A 641 M), Class 1 zinc coating, soft temper, 0.062-inch thick. INSTALLATION : Inspect wall surfaces to receive crash rails. Notify the Architect in writing if wall surfaces are not acceptable. Do not begin installation until S P C Re m od e I Hangers : Wire, ASTM A 641 (ASTM A 641 M), Class 1 zinc coating , soft temper, 0. 162-inch diameter, unacceptable conditions have been corrected. Install corner guards to walls securely in accordance with manufacturer's written instructions. Install corner Warranties: Carrying Channels: Cold-rolled steel, 2 inches. guards accurately in location, alignment, and elevation. Submit written warranties to the Architect prior to the date certifed for Substantial Compietion. If the ArchitecPs Certificate of Substantial Completion designates a Furring Channels: 7/8-inch deep, cold-rolled channels. commencement date for warranties other than the date of Substantial Completion for the Work, or as a designated portion of the Work, submit written warranties upon Steel framing for partitions complying with ASTM C 645. Installation: request of the Architect. Studs and Runners: In depth indicated and 0.0179-inch thick, unless otherwise indicated. Secure mirrors to walls in concealed, tamperproof manner with special fingers, toggle bolts, or screws. Set units plumb, level and square at locations Rigid Hat-Shaped Furring Channels: In depth indicated and 0.0179-inch thick, unless otherwise indicated. indicated, according to manufacturer's instructions for type of substrate involved. � 8 � W . Meadow D rive When the Contract Documents require the Contractor, or the Contractor and a subcontractor, supplier or manufacturer to execute a special warranty, prepare a written Furring Brackets: Adjustable serrated-arm type fabricated from corrosion-resistant steel sheet 0.0329-inch thick. Install grab bars to withstand a downward load of at least 250 Ibs, complying with ASTM F 446. document that contains appropriate terms and identification, ready for execution by the required parties. Submit a draft to the Owner, through the Architect, for approval Provide double 16 gauge studs at each doorjamb; extend to structure above. Provide 20 gauge studs at 16" O.C. behind casework; provide 25 gauge studs at 16" o.�. Va i I Colorado elsewhere; unless UL assembly requires different gauge. WaII PYOt@Ct1011 : � prior to final execution. Where new partitions adjoin existing construction, the new finished face shall align with the existing finished face unless noted otherwise. H � GG7 Product Data: Submit manufacturer's product data including installation instructions. V �� At Final Completion compile (2) two copies of each required warranty properly executed by the Contractor, or by the Contractor, Subcontractor, Supplier or Manufacturer. Samples: Submit 7" x 9" ( 177.8mm x 228.6mm) sample of each type, thickness, color, and texture to be installed for ArchitecYs approval. Gypsum Board Assemblies : MANUFACTURER: In Pro Corporation SanparrelGT Sheet: Rigid high-impact acryliclpolyvinyl chloride (PVC) 4'-0" high roll goods. Thickness: 0.060" . Organize the warranty documents into an orderly sequence based on each technical Specification Heading. Gypsum Wallboard: ASTM C 36, in thickness indicated , with manufacturer's standard edges. Texture: Standard. Furnish adhesives approved by protective wallcovering manufacturer. Furnish accessory moldings by protective wallcovering Request inspection for certification of final acceptance and finally payment, once the following are complete: Regular Type, and Type X where required for fire-resistance-rated assemblies. Water resistant. manufacturer to ensure accurate match of colors, dimensions, and physical properties. Furnish color-matched caulk by protective wallcovering Submit final payment request with releases of liens and supporting documentation. Moisture Resistant Non-Rated Board: ASTM C 630, in thickness indicated . Regular Type and Type X where required for fre-resistance-rated assemblies. manufacturer to ensure accurate match of colors. Include insurance certifcates. Accessories for Interior Installation: Cornerbead, edge trim, and control joints complying with ASTM C 1047, formed from steel sheet zinc coated by hot-dip process or SURFACE PREPARATION: Prepare walls in accordance with manufacturer's written instructions. Remove dust, dirt, grease, oil , loose paint, scale, and Submit consent of surety to final payment. rolled zinc. Apply appropriate acoustical and water resistant sealants at all penetrations and joints. existing wallcovering. Resurface uneven wall surfaces and damaged walls. Seal walls with white prime seal. On completion of re-inspectlon , Architect will prepare a certificate of final acceptance. If the Work is incomplete, Architect will advise Contractor of the Work that is Finishing Gypsum Board Assemblies: In accordance wilh GA-214; Level 4 finish , unfess otherwise indicated; Level 1 finish for concealed areas, unless a higher level of EXAMINATION : Ins ect wall surfaces to receive rotective wallcoverin . Noti the Architect if wall surfaces are not acce table. Do not be in installation incom lete or obli ations that have not et been fulfilled. finish is required for fire-resistance-rated assemblies; and Level 2 finish where panels form substrates for tile. P P 9 � P 9 p 9 y until unacceptable conditions have been corrected. INSTALLATION : Install protective wallcovering to walls in accordance with manufacturer's written instructions. Allow protective wallcovering and adhesive SPEC I F I CATI O NS Selective Demolition: to precondition for a minimum of 24 hours at a temperature between 65°F and 85°F before installation . Install sheets with texture running in the same Unless otherwise indicated , demolished materials become Contractor's property. Comply with EPA regulations and disposal regulations of authorities having jurisdiction. direction for uniform appearance. Conduct demolition without disrupting Owner's occupation of the building. Items indicated to be removed and salvaged remain the Owner's property. Remove, clean and pack or crate items to protect against damage. Identify contents of container and deliver to Owner's designated storage area. All light switches, telephone, electrical, data outlets, etc. indicated to be removed or relocated shall be completely removed. Patch and apply finish indicated. A cover plate DATE 2 APRIL 2007 will not be acceptable. Elld Of Sp@CIfIC8t1011S . DRAWN BY CD Submit schedule indicating proposed sequence of operations for selective demolition work to Owner's Representative for review prior to start of work. Include coordination CHK 'D BY SN for shutoff, capping and continuation of utility services as required, together with details for dust and noise control protection. MODEL FILE AO- t . dwg Provide detailed sequence of demolition and removal work to ensure uninterrupted progress of Owner's on-site operations. Conduct demolition work in manner that will COPYRIGFIT 2007 BY DAVIS PPRTNERSHIP P.C., AFtCHITECTS minimize need for disruption of Owner's normal operations. SHEET NUMBER: Maintain and protect existing utilities to remain in service before proceeding with demolition, providing bypass connections to other parts of the building. Locate, identify, shut off, disconnect, and cap off utility services to be demolished. Protect remaining walls, ceilings, floors, and exposed finishes. Erect and maintain dustproof partitions. Cover and protect remaining furniture, furnishings, and equipment. Promptly patch and repair holes and damaged surfaces of building caused by demolition. Restore ■ exposed fnishes of patched areas and extend finish restoration into remaining adjoining construction. Promptly remove demolished materials from Owner's property and legally dispose of them . Do not burn demolished materials. D. P.A. PROJECT # 06938 .00 1 � ' • - � Archit ts 2301 BLAKE ST., STE. #100 DENVER, COLORAD080205 303.861 .8555 F.303.861 .3027 0225 MAIN STREET . UNIT C101 EDWARDS, COLORADO 81632 970.926.8960 F.970.926.8961 EXISTING SMOKE COMPARTMENT-CENTRAL CATORRUMABASSOCIATES, co. 1550 DOVER STREET, SUITE 2 21 , 375 SF , TYPE I CONSTRUCTION �AKEw000, C080215 ISSUE/REVISION DATE NO. TOV CODE REVIEW 1JUNE07 EXISTING SMOKE COMPARTMENT-WEST 19 , 126 SF , TYPE I CONSTRUCTION � � � i � � � � _ �� �_ � � � i � � � �03 � �i I THIRD=21 a SECOND=43 - - - � OCCUPATIONAL �� � MRI 8 , , j sss s FTH 1 ,579 S . F. - 696/240=3 � � ,579/ 0= 1 - � i = LAB I 1 ,715 S . F. _ 1 ,71 - I :� �.�- 7 � ' �pF O( Q 1 � o°� ADMISSIONS T � E " � ~� � � �p _ � ����� ����� � ������ � 9 9 1 _ ❑o . . 9 � RF � IM� s. . � - , SCOTT MICHAEL - ❑00000 10 SEATS 894/100=9 , I * NEVIN ilt o � LOBBY 3C6 SI• F• 2 , � 6 / o0 2 � PHARMACY � 1 ,413 S . F. _ _ _ <� 2�2985 G 15 SEATS � $ 00❑00 0 ❑ 0 p❑ _ ' ' S 60R. C+�� �\,�t�, 49 � 7 � - - - � I BUILDING S ---.._._.... - -- - ..- --- , BUIL Ze ///////////////// 1 ° ' S� A�� � / ATRIUM F � ��rnn-- � 1 ,577 S . F. � , ! � - - Ibl SUPP RT � -�1ldtiLULlt�u � 16 SEATS $ O ' 373 S . F . 570 S. F. 6 S. F . 2 ,470 S . F. � � � �❑ 0 �� ❑ � / �uL_ 1 � � = 2 ,470/300=9 T SHOP / Qoaoo r- y n❑ _ 65 2Rpj3pP g - / _ E 27 THIRD-48 / � IMAGING - CORRIDOR 886 SF=9 SECOND=50 RECEPTION ������ - / 4 �i8$ oo=s " �25 E12 - 1 117 CONVER ENCE � BASEMENT=67 391 S . F. � m pT / � _ IT FOR SHF � ii 1 STE — 391 /100=4 pp m 1 ,240 S . F. / � 589 S . F. �y - 33 _ 2 ❑ 1 ,240/100= 13 / , 589/100=6 y I Hq � J, � • „ WAITING / 4 � � 5 . F. MEDIC L RECOR V 20 S ATS / _ _ / � M �9 i 1 ,487 S . F._ 1 a � l / - � � � � _ 1 ,487/300-5 / y 10 � � Valle 11 �� R - / _ � - � - -� o - 2 39 � 0 = 21 �' — 24 � - / _ _ / ' ' _ - - - � � � � 6 Medical =R 21 23 - / / � p 1 - � � / � I i c� C RID 220 S =3 � CO , - �1 � _ SPC IN -PATIENT Center 15 882 S F � PHARMACY � � 815 S . F. � ❑ r N C . MED . 82/300=3 815/100=9 HOWARD HEAD � S • F • SHIPPING/ 3 ,32o S. F. ADMIN . � _ a / 00-5 1 3,320/100=34 � MRI 305 S . F. � RECEIVING o 0 326 S . F. f i 1 ,010 S . F. 56 1 ,010/300=4 � 2 J� - 1 „ i � � THIRD=28 � SECOND=49 'i�� COLORADO MOUNTAIN MEDICAL � � First Fioor s ,aoo s . F. � ` '. .. i EXISTING SMOKE COMPARTMENT- EAST 3 ,800/100=38 , THI D 72 . � 15 11 ' ., I L _ � � '� ���� ���� 14 , 513 SF , TYPE I CONSTRUCTION sE O D=73 Nuclear Medicine 140 CONVERGENCE �. < �� ❑ , B A E E N T=6 7 S T E A D M A N H A W K I N S F O N D A T I O N C A R D I O P U L M O N A R � 0 � � ❑ o ❑ ❑ � � � � O ❑ S PC Re mod el ❑ ❑ 2 UfF 4 489 S . F. 4,489/100=45 2 , 182 S F 2 , 182/100=22 , , , � ,;;,,,; � �` _ � ,� ' I , � � i , r� . .. :� �r�� �i � � � � � ���. \ A !N(I 1( It ii�i�— .. ._ ....... . .c..... . ............ . .............. ' �. .. ......... .........v..... � 4/ � 'u�TN�' b�MIR � 'bl.ATC 'ulJaB ��Wi. .'WfJ�n iwNJ "vW�e' 'L�� ������ . Q � v �L�� ,.. N n1 , u � . . .. . �/��{,����� '�. v.:. fHC ��1//Il�i ' O � � � � � \ I � O \'. .. ...... . I .liiJR 181 W . Meadow Drive � s �t :�;�.,, � Y°,� � � °°�� : ����" Vail , Colorado . :,, �,: ,. �, wF� � - 81657 ,. . . . II.C..S i'�I v SNIif WAI X �—� FIRE RESISTIVE REQUIREMENTS: "' PARTITION TYPE LEGEND OCCUPANCY LEGEND CONSTRUCTION RATING ' ' WEST MEADOW DRIVE j8'-0" CORRIDOR WIDTH STRUCTURAL FRAME 3 HR = / —�—�—�—�—�—�—�— 1 HR FIRE / (GURNEY EGRESS) ( INCLUDING COLUMNS , GIRDERS, AND TRUSSES ) - BEARING WALLS . LIFE SAFETY PLAN EXTERIOR 3 HR •��—��—��—��—��—��—��—��• 2 HR FIRE INTERIOR 3 HR � , OCCUPANCY & SEPARATIONS NONBEARING WALLS AND PARTITIONS � 11 � 11 � 2 HR FIRE/SMOKE BARRIER NOTE : GROUP B OCCUPANCY EXTERIOR 0 DATE 2 APRIL 2007 (UNLESS NOTED OTHERWISE ) INTERIOR 0 DRAWN eY co FLOOR CONSTRUCTION 2 HR ( INCLUDING SUPPORTING BEAMS AND JOISTS ) CHK' D BY SN ROOF CONSTRUCTION 1 . 5 HR MODEL FILE A1 — tfpl .dwg ( INCLUDING SUPPORTING BEAMS AND JOISTS ) COPIRIGHT 2007 BY OAVIS PARTNERSHIP P.C., PRCHITECTS SHAFTS 2 HR SHEEf NUMBER: , LIFE SAFETY PLAN ( INCLUDING ELEVATOR) � AR 1 . � EXIT STAIR ENCLOSURES 2 HR R 1 . 1 � 1 6 " = 1 ' - 0 " 0 8 ' 1 6 ' D. P.A. PROJECT # 06938.00 1 � ' • - � Archit ts 2301 BLAKE ST., STE. #100 DENVER, COLORADO 80205 303.861 .8555 F.303.861 ,3027 0225 MAIN STREET . UNIT C101 EDWARDS, COLORADO 81632 970.926.8960 F.970.926.8961 EXISTING SMOKE COMPARTMENT-CENTRAL CATOR RUMA & ASSOCIATES, CO. 21 , 375 SF , TYPE I CONSTRUCTION 1550 DOVER STREET, SUITE 2 LAKEWOOD, CO 80215 es occuPnrirs ISSUE/REVISION DATE NO. REOUIRED ECRE55 WID7H=19' PROVIOED WIDTH�70' Ir EXIT DISCHARGE TOV CODE REVIEW 1JUNE07 EXISTING SMOKE COMPARTMENT-WEST - ---- --��- --- ' ii � � i 19 , 126 SF , TYPE I CONSTRUCTION 64 OCCUPANTS � _ �� _ � _ i � REQUIRED EGRESS WIOTH�12.8' II� � a PROVIDED WIDTH641 " — �I EXIT DISCHARGE � � �°' � — ' I s� � �� � , , „�� � � I 8'� I � � - i j - � I I� ... J !...._.... — �_� ' __ '_ _ — �r` _ 262' I �F/ /� ` ' VO� � - -- -� � �- j �o � _ __ _� � � � ,�_�� ��_�� � ,�_��_ - , bs� , n SCOTf MICHAEI � . � �� � � �! l� � wio�D3°a. � * NEVIN �C EXIT DISCHARGE PXISTING HORIZONT - � -� __ ' __ - ��� 202985 ��� _. .-_ ---__ - -- --- _. �_,_, 36 OCCUPANTS, REOUIRED .2" (CENiRAL) i _ /� \ 49 OCCUPANTS � 96 OCCUPANfi WIDTH� 19.2' (WEST) � t95. — I II 331 ' SE ({ , REOUIRED EGRESS WIDTH=9.8' PROVIDED WI�TH=71 ' ------- ' PROVIDED ❑ �j � � � ��M�! y; nTRn�- � � I fr' _ _ �_ I I WIDTH=73 -�L46LluLl� �'� � � ----;� — �.LLL�� I � � r REOUIRE� EGRESS WIDTH=13' L _ (�� � ;� _ _ _ � II = � 'I' � EXISTING ORIZONTAL EXIT � 99.5� � i �___ DISCHARGE ;n � I �-.-� �-� � � ;; 65 OCCUPANTS � - ^ „ � ocaaurrs T_... . '', :.....,; �---� . PROVIDED WIDTH�39' PROVIDED WIDTN�42 � �� �I, 'I -- I �� 55 OC�U�ANTS, REOUIRED WIDTH= 11 ' CENTRAL 29 OCCUPPNTS REOUIREO WID =5.8 (EASn � � REOUIRED EGRESS WIDTH�23.4' PROVIDED WIDTH=45. I� I�, 1 EXIT DISCHARGE _:::_ _ . � , - . I . _ !�_ 1E��. _. . _ , - � ' ,�� _ II .. ... ...... ' ' 199' � ��_���._�� ''- I I � k I I , . :,\� ,� _ _ �� �� � � - Vail ,; --__� � '� .:��4 a � ',f - , � � � - � Valley , , , �� � � � L �,, _ � - �� � ,� - � o �� . - � „ �. _.... __ , , f--_-_ .:_ , , d . 8z� L �� � - '' — � 3�. - - - , , � � Me � cal _ � - _ __ . . . _ ....... ._.... �._. ..._. .....� 153' _ � — j .......__. ._._. _I - � � � � � I� i � 49 � _ , Center 183' II � 252' � i � � � L�'�',,.�q� .. I r ❑ � , -� ��' o -- o � ��� -, � '� : .- - _,�� i �� � ; - , �� i , � � � ,r---:_---:�, ;���\ � :� II � � ��� _—. ',! ,�_� � � �,,Exi -r � i C ARGE � �� �� � First Floor EXIT DISCHARGE 140�'QCCUPANTS � .. I .F.E' 56 OCCUPANTS � "'�'° Nuclear Medicine � REOUIR�D EGRESS WI H�2 �� v.v.[- � — � . . ... . REOUIRED EGRESS WIDTH�11 .2' � PROVIDED WID7H�39' eia.a PROVIDED WIDTH�41 ' ii 77 OCCU SIDEWAII(�80' r.r.c.. REQUIRED DTH=15. • 15 OCCUPANTS ma.25' � 11 OCCUPANTS I 45� �'1 \ REOUIRED EGRESS WIDTH�3' m i REOUIRED EGRESS WIDTH= 1 .2', 1 � Q � _ � . PRONDED WIDTH=36' � a0 PROVIDED WIDTH�36" ❑ � ❑ ❑ ❑ ❑ � ❑ .� � � � ❑ ❑ , . .... ...... .. - �� V P C Re m od e I � RI 1 N!1 PA'.q"11`1 _ � , � I , r"—'\ % � r.�i--� �f�,��E� _ Q�NNER TO MAINTAIN 44" �R EGRES iR 1TE ^ ' ��aweo r c ncaNSr o�oN ec ess ' ?�,��(� d�Ah ��,i� `'diAt�' �E�C:' d�ACr d �' '�d�A1w *triA1E' *d�,tr <d ' `�%� \ ` d_� �.� i ��s n_,� ,� �u� � rZnvE�„���+., n i ooa. i .2 ec � � �Q ' x` ,"" ""' " °`"`: n EXIT DISCHARGE ��� EXISTING SMOKE COMPARTMENT - EAST / .....` � 6'-Ow io PROVID DuWO 572'D �20.8� �aiui��rvc; , � .. ;��' ���� ���� ��'� ���� ,�a 14 , 513 SF , TYPE I CONSTRUCTION 181 W . Meadow Drive o ,. rx: � � ,�� �„�:.,�.����; Vail , Colorado i � ir� �. sne.v;pu. . !' %".SliNf,i y.l)f:NAI.R ' _ . 81657 . � ' . �:+�sm+as�t.errva�n .. .. . . . ' ' ca�sr;moeuasreF „ � � ' . PARTITION TYPE LEGEND \ NOTE: �. \ . .. EGRESS WIDTH FOR SfAIR DOORS � ' . IS BASED ON CODE ALLOWANCE � '� ' . �� "� � � FOR EGRESS WIDTH TO BE BASED C...4"' � ON ACCUMULATION OF SECOND WEST MEADOW DRIVE - � � �. .. � . AND BASEMENT CONVERGENDE � " . t=" . (_�,,1 . .. � . -�-�-�-�-�-�-�- 1 HR FIRE LIFE SAFETY PLAN .�����������������������. 2 HR FIRE . EGRESS � 11 � 11 � 2 HR FIRE/SMOKE BARRIER DATE 2 APRIL 2007 DRAWN BY CD CHK' D BY SN MODEL FILE A1 - 1fpl .dwg � COPYRIGHT 2007 BY DANS PMTNERSHIP P.C., ARCNITECTS SHEET NUMBER: , LIFE SAFETY PLAN � AR 1 . 2 R2 • 1 / 16 " = 1 ' - 0 " 0 8 ' 16 ' D . P .A. PROJECT # 06938.00 1 CORRIDOR u � � J u � � ii � - - - - - - - - - - - � - - ' IrD2 I � � � � � � � I CON OLS � I r � � � � � � . • - � � • � Archit ts I I i Sf—��ILEDO I - - I I — — — � I I_� D5 r � I � I CAR100ASH ' I I ' I i � I I � � - "1 i JANIT�R STORAGE I I I I - - - - - - - - D1 - NO WORK � i i 0 � (� � 5 I � i i i �O � � � � — I�- il— 100 � � � � � �"� 2301 BLAKE ST., STE. #100 � � NO WORK NO WORK � � � � � � � � T� q2.o DENVER, COLORADO 80205 � _ _ � _ 303.861 .8555 F.303.861 .3027 r - - - � � � � I � I � PUSH 1 1 O � EDW RDS, CO OR,4DOI816321 � � � � iv 102 970.926.8960 F.970.926.8961 � � � � - - - ( � i i � I _ I CG 9 -0 I � +i C �RRIDOR � q ' � i � I � ' D4 1 i � D4 I � I CORRIDOR SPC I HALL , i i � 101 nz.o 102 � 107 I I , I � � I I I � , oi FEC � I I L - - - �I - - - I � Po CG � - - - - - - - - - I � I - - - - - - - - - - - - - � � � REfER TO A0.0 FOR KEYNOTES r r� IL - - - - - - - - - - - - - - - - - - - � i � � � � I � CTION 0 V � � i ` I � i i i f � I /f � 3 103 105 � 106 _. 2 _ I � E � � , , , � � , , , �o �', �� � � i � � � � � � � STERILIZER NUC MED i ' I '-2" 1 ' 8" 8� °� � 105 (by Owner) I - � I p2 � ' � i SPC STORAGE � i � ' O O I I 5'-6" � I I �� ' I ^ i � ii I i i � . ' , i i O O I e+ �i CAMERA ^� i i � � � i i M, ;,, (by Ow er) �o : . _: i i � � i i i D5 `__ ; � , ' L _ = � � _ = I � , s'— , ° I i DS i r ' 1 � rack 8�_5• CG 11 '-8" 13�-5�" CATOR RUMA & ASSOCIATES, CO. 1550 DOVER STREET, SUITE 2 � � D3 � � � � r - I � STERILIZER I LAKEWOOD, CO 80215 i � � � � NUC MED � safe o STERILIZER (by Owner) I i � � � ' O � 1 I I WQRK `� 106 I ISSUE/REVISION DATE NO. i i � ii i 104 � I i SPO ii D5 � i I I 0 9 � I TOV CODE REVIEW 1JUNE07 i � � � ' ' i i � I 13 nz.o I � i i SPC ST �RAGE ^ ` � � i I I I 12 � a lo � STERILIZER I � I �� i i � r � � i I I � � �o _ (by Owner) STERRAO I I i i i i � � � � i I I � _ _ _ CONTRACTOR TO COORDINATE � STERILIZE j I � � D3 � ! _ _ _ _ _ _ J ` _ _ � � \ � � i EQUIPMENT LOCATION WITH SIEMENS -�,� (by Owner I I � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � /\ � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � / ��� , DEMOLITON PLAN 2 FLOOR PLAN , , A1 . 0 � �4 „ = 1 ' - 0 " p 2 � 4 ' A1 . 0 1 /4 " = 1 ' - 0 " 0 2 4 a °� °� U o _ _ _ _ _ _ _ � * SCO NEVINHAEL * I '�'`"Q � 202985 � — — — — — — < G� , � � I CO I I � ��NSF ARG�, 7/" I �,� � � I � 3G ' � -- � � `--��: � � T w 5t� : � — — — — � , � � � i..+ �..,r ..L�'^,.+�r .■r. � � � � � �" t O , ' f' � EXISTING GYPSUM BOARD CEILING '' , EXISTING G SUM BOARD CEILING ; ' TO REMAIN; INFILL FLUSH AS gp� TO REMNN; INFILL FLUSH AS REQUIRED FROM REMOVAL ' ', � p2 REQUIRED FROM REMOVAL I • . , , . � . V 1 ' . OF LIGHTS OR OTHER D CES �OF LIGHTS OR OTHER DEVICES . , , `. CORRIDOR• " I �� -�- �-- . � � �-- : - � E�U�� , � Q :, �� �� �Q��� � Valley rECH wo K � I 103 I ' - � � � Medical � , . . , . , , � .. . . . � , . . . > � 8 -� PROVIDE GIPSUM WR4PPE PROVIIE GYPS M WRAP ED , Center HEADER AT OPENNG; BO OM HEAD R AT O� ENING; B TfOM OF DR ALL TO E 7'-2" OF D YWALL T BE 7' 6" I INJE TION O I 103 0 � � � I � , 8 � ��� J � I � . . - _ ... .._...� .. .� I ; I o � Uc05 ' First Floor � WORK $ � _ 6�� O 8� _ 6 „ I 104 � ' ' S ERILIZ R � Nuclear Medicine ` � � o 0 0 106 0 0 � SPC Remodel ,,..' I � � , I � O ' . I 1 , � � 181 W . Meadow Drive � , _ � Vail , Colorado � - - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - 81657 3 REFLECTED CEILING PLAN A1 . � � 4,� _ 1 ' - 0 " p 2 ' 4 ' DEMOLITION , FLOOR AND REFLECTED CEILING PLANS DATE 2 APRIL 2007 DRAWN BY CD CHK 'D BY SN MODEL FILE A1 - 1fpl .dwg COPYRICNT 2007 BY DAVIS PARTNERSHIP P.C., PRCNITECTS SHEEf NUMBER: A1 . 0 D . P.A. PROJECT # 06938.00 REFER TO 19, zo, 2, i�. , DOOR AND FRAME SCHEDULE FINISH SCHEDULE FOR JAlAB AND HEAD DETNLS 1 '-O6. Z -�� DOOR NAME DOOR FRAME FIRE HARDWARE NOTES N0. NAME FLOOR BASE WALL CEILING REMARKS 3'-0" 2" 2" RATING SET NO VA*-�-* 6" 2'-0" 6" VARIES TYPE WD HGT THK TYPE HEAD JAMB NORTH EAST SOUTH WEST I I TEMPERED � GLASS . N 100 CART WASH D1 3� - 6° 7 � -0�� 1 3/4° F1 1 A2 . 0 2 A2 .0 20 MIN . A 14 GA GALV FRAME; 100 CART WASH CTF1 CT61 CTW1 CTW1 CiW1 CTW1 PT2 FULL HEIGHT WALL TILE I ' 16 GA GALV NM DOOR 101 CORRIDOR CPT1 R81 - PTt PTi PT1 PT1 } iO ^0 101 CORRIDOR D3 4' - 0 " 7' -0 " 1 3 4" F1 1 A2 .0 2/A2 . 0 45 MIN . B WOOD DOOR 102 SPC SVi SVB1 PT2 WP PT2 WP PT2 79 PT2 WP PT2 ACT1 4�-0" HIGH WALL PROTECTION • • � Archit lS `" � 102 SPC D3 4 � -0 " 7' - 0" 1 3 4" F1 1 A2 . 0 2/A2 .0 45 MIN . � WOOD DOOR 103 INJECTION SVi RB1 PT1 PT1 PTt PT1 ACT1 ° ° TEMPERED; ° 104 WORK SV1 R61 PT1 PT1 PT1 PT1 ACT1 ^ ^ 20 MIN " 103 INJECTION D1 3� -0" 7 � -0 " 1 3/4�� F1 1 /A2 .0 2 A2. 0 20 MIN D WOOD DOOR 105 NUC MED SVt R81 PT1 PT1 PT1 PT1 ACT1 o RATED o 105 NUC MED D1 4' -0" 7 ' -0" 1 3/4�� f1 1 /A2 .0 2/A2 .0 20 MIN D WOOD DOOR 106 STERILIZER SC RBt PTt PTt PTt PTt ACTt � GLASS a 107 CORRIDOR VCT1 R81 PT1 PT1 PT1 PT1 PT1 106 STERILIZER D1 3 ' - 6 ° 7' - 0° 1 3/4" F1 1 /A2 .0 SIM 2/A2 .0 SIM - - - E WOOD DOOR 2301 BLAKE ST., STE. #100 DENVER, COLORADO 80205 WOOD/METAL DOOR WOOD DOOR WOOD DOOR INTERIOR WITH WINDOW WITH WINDOW HOLLOW METAL HARDWARE GROUPS LEGEND FINISH KEY 0225MAINSTREET . UNITC101 D 1 D2 D3 F 1 EDWARDS, COLORADO 81632 970.926.8960 F.970.926.8961 DOOR TYPES FRAME TYPES Group #A 3 HINGES WD107S RHOX 4 1 /2 US32D MC - NON FERROUS GL - GLASS UM ABBREV. TYPE RECOMMENDED MANUFACTURER SIZE PRODUCT ID & COLOR REMARKS 1 PASSAGE SET 62g SC 1 WALL BUMPER WS407CCV US32D �V HM - HOLLOW METAL SC SEALED CONCREfE CLEAR 1 SMOKE SEAL S88 D 20 ' pE MIN - MINUTE 1 PROTECTION PLATE K1050 10 "X40 " PUSH US32D R� PT - PAINT 1 CLOSER- DELAYED ACTION 41 1 1 DEL US32D LCN STL - STEEL ACT1 ACOUSTICAL TILE ARMSTRONG 24"X48" SQUARE LAY-IN CLEAN ROOM VL (NONPERFORATED) T - TEMPERED CG CORNER GUARD IN PRO 48" HIGH 150 HIGH IMPACT Group # B 3 SWING CLEAR HINGES T4A3786 5 X 4 1 /2 2gp MC BE - BEST WP WALL PROTECTION IN PRO 48" HIGH ROLL SANPARREL GT SHEET - OATMEAL CAULK TO MATCH 1 PUSH PULL LATCH HL6 US32D S� IV - IVES W/ ELECTRIC STRIKE 4840 - 60 ggg LCN LC - LCN pL1 PLASTIC LAMINATE WILSONART 4813-60 NICKEL EV HORIZONTALS 2 TOUCHLESS ACTUATORS MC - MC KINNEY � � 5/8" GIPSUM BOARD 5/8° TYPE 'X' GYPSUM BOARD 1 SENIOR SWING AUTO - OPERATOR 9540 PUSH SIDE ggg LCN PE - PEMKO PL2 PLASTIC LAMINATE FORMICA 958-58 BEIGE (VERTICALS) (CLOSER) RO - ROCKWOOD 1 PROTECTION PLATE K1050 36 "X46" PUSH/8 " PULL US32D RO SC - SCHLAGE DOUBLE STUDS BACK TO BACK AT JAMB 1 SMOKE SEAL S88 D 20 ' PE - PT1 EG SHELL PAINT SHERWIN WILLIAMS _ VELLUM SW1116 MTL. HEAD TRACK PT2 EPDXY PAINT SHERWIN WILLIAMS VELLUM SW1116 R4TED HOLLOW MEfAL FRAME MTI. CLOSURE TR4CK Group #C 3 HINGES T4A3786 5 X 4 1 /2 626 S� PT3 SEMI GLOSS PAINT SHERWIN WILLIAMS CROISSANT SWt 114 HOLLOW METAL FRAMES CATOR RUMA 8 ASSOCIATES, Co. 1 STORE ROOM LOCKSET ND80PD RHO 10 - 025 � FIRE CAULK FRAME TO WALL � 1 WALL BUMPER WS407CCV US32D 1550 DOVER STREET, SU�TE 2 FIRE CAULK FRAME TO WALL R� LAKEWOOD, CO 80215 �- 1 PROTECTION PLATE K1050 36" X 40 " US32D UNIVERSAL WELDED STEEL STUD ANCHORS, 1 CLOSER 4041 US32D LCN R81 RUBBER BASE ROPPE 4" HIGH � 172 CHAMPAGNE `" �' `" �' RECESSED 1 /2" FOR STUD AND G1P. BD. 1 SMOKE SEAL S88 D 20 � PE ISSUE/REVISION DATE NO. - .- CPTi CARPET LEES CARPEi BROADLOOM D7006 BELLO 203 MESA MC TOV CODE REVIEW 1JUN07 RATED WOOD DOOR RATED HOLLOW METAL FRAME; RE: A0.2 Group # D 3 HINGES T4A3786 5 X 4 1 /2 26D SC SVi SHEET VINYL MEDINTECH ROLL 86497 BRUSHED SAND WELDING ROD TO MATCH 1 LOCKSET 626 1 WALL BUMPER ND53PD RHO 10- 025 US32D �� SV61 SHEET VINYL INTEGRAL BASE MEDINTECH 4" 86497 BRUSHED SAND R4TED WOOD DOOR RE: A0.2 1 SMOKE SEAL �NS407CCV pE 1 CLOSER 4041 D 20 US32D LCN CT81 CERAMIC COVE BASE TILE AMERICAN OLEAN 4" HIGH GLOSS ALMOND 0012 VERIFY EXIST. VERIFY EXIST. �� CTW1 CERAMIC WALL TILE AMERICAN OLEAN 4°X4° GLOSS ALMOND 0012 PARTITI N PARTIiION Grou E 3 HINGES 26D M� CTFt CERAMIC FLOOR TILE AMERICAN OLEAN 2"X2" UNGLAZED CERAMIC MOSAIC LINEN A07 NEW PARTITIONS NEW PARTITIONS P # T4A3786 5 X 4 1 2 SC COORD. WITH COORD. WITH 1 PASSAGE SET � 626 PARTITION SCHEDULE PARTITION SCHEDULE 1 WALL BUMPER y�/S407CCVO US32D �� G1 fL00R AND WALL GROUT MAPEI ALMOND 48 1 HM DOOR HEAD AT RATED WALL 2 MH DOOR JAMB AT RATED WALL vcTi VINYL COMPOSITION TILE ARMSTRONG � 2X � 2 IMPERIAL TEXTURE SANDRIFf WHITE 51858 A2.0 3" = 1 ' -0" A2.0 3" = 1 '-0" �� FIRE STOP SEALANT. 5/8" NPE 'X' GYP. BD. - -- -- vusric uMiru� oveR > >/4• � ���r-. 2,- � • 2,- � , MDF BOARD ON FRT BLOCKIN � ' � �-3� C�L CONTINUOUS DOUBLE STRUC�TURE. �'-�' � STRUCTURAL STEEL STUDS ~ GYP. BD. � GYP. BD. � . P��C UMINATE OVER � �/a' �OO AT EACH JAMB, SILL AND � � , �� MDF BOARD WITH PVC EDCE � HEAD; WELD TOGETHER AND �e EXTEND TO STRUCTURE 4" BACKSPLASH DRAWER � DRAWER • � �/z•x� /z� �F' REVEAL * SCOn MICHAEL , ADJUSTABLE NEVIN �C ' �i EXTRA DEEP GYP. BD. SHELVES __ ......... . ........ 4" BACKSPUSH _ � MODEIL ADRMFRSOL so oR 4� ��� V �� i ' i RUNNER CHANNEL ' COUNTERTOP 2 Q 2 9 85 /� ANCHORED DIRECTLY ! "' RECESSED - -- ----- _ QUUV�ncruR SL PER �, - - '� TO SLOPED CONCRETE ° STANDARDS DRAWER �' P�NT MENDATIB�K �tiS+fi� G � "" ROOF ABOVE 20 GA. SHEET MEfAL &4CKING � a 20 GA. SHEET METAL BACKING � � �, _,,, CONT. BEHIND CASEWORK � CONT. BEHIND CASEWORK COUNTER TOP SHIM , AS REQUIRED i � W -- HOLLOW METAL FRAME 3 5J8" METAL Y� FLYWOOD BACKING � ADJ. SHELF ` M 20 GCONT.E EHI D CASEWORK RAWER �, � STUDS � 16 "OC , 'y,; Pusn� w�iw�� �RON vnTM � �" FRONTS i o Pusnc v�uu� nric�o � 1 2 " METAL STOP 5 8" TYPE �" FRONTS � SUPPORTS AND WALL BRACKEf / � > Y" PLYW000 BACKING N �" FRONTS "' s/e' GYPSUM BOARD OVER "X" GYPSUM BOARD RECESSED Y" PLYW000 BACKING -' TEMPERED GLASS BOTH SIDES. 1x WOOD BLOCKING STDS. 1x FRT WOOD BLOCKING DRAWER �, � 3 5�8� ZQ18�' OC.SCLIP TO iz FRT WOOD BLOCKING -- �ooR wini nnc� 2x FRT WOOD BLOCKING 2x FRT WOOD BLOCKING VERIfY EXIS7. 0 ....� "� PARTITION NEW PARTITIONS � � Vail COORD. WITH COMPACT 3' 3" PARTITION SCHEDULE FLUORESCENT FIXTURE Valley 3 HOLLOW METAL WINDOW FRAME 4 PARTITION TYPE 1 HEAD DETAIL 5 UPPER CABINET W ADJUSTABLE SHELVES 6 CABINET W ADJUSTABLE SHELF AND DRAWER 7 CABfNET W 4 DRAWERS 8 SECTION AT WORK COUNTER ' - 1 �-0" A2.0 3"= 1 ' -0�� A2.0 1 ° = 1 ' -0° A2.0 1 " = 1 � -0° A2 .0 1 " = 1 � -0° A2.0 1 " = 1 � -0° Medical A2.0 3' - $ Center 5 a �.� 3° 'nz•° ^z•° SIM . 2" HOLLOW METAL PAINTED FRAME 1 '-3" 2'-6° 2'-6" 1 '-6" 1 '-3" � �-3� 3'-0" 3'-0" PARTIAL HEIGHT STUD WALL 2" HOLLOW MEfAL PNNTED fR4ME FULL HEIGHT WITH 1 /4° TEMPERED GLASS � WITH LAMINATE CAP WITH 1 /4" TEMPERED GLASS STORAGE CABINEfS 3" WITH ADJUSTABLE SHELVES �o -� �o `O N FEP tO N FEP / ��-�� "' V "' � / � \ a UCL � I � � 0 � o � o M E uc� � o - P� FEP 0 N � � o PT � First Floor � � � - - - = SAFE RACK KBT I � N M � � �� � � � � EP � � I -� � Nuclear Medicine � � � � SPC Remodel � \ � M M, �, FL2 . , _......_.._ '" � � _�� J _ __ �� �- �_ CORNER GUARD 2'_0^ T 2'_ 1 " 2'_9• 2'_9" 2'_0" 2'-0" 1 '-6' 1 ' 6" 2'-3" 6�'�� 6'-6" PLASTIC LAMINATE SUPPORT � -9� 2 -9� EXISTING ELECTRICAL PANEL 3" 3" 3� � � FIELD VERIFY WIDTH OF CABINETS 6 � TO PROVIDE 30" REQUIRED n2.o n2.o CLEARANCE IN FRONT OF PANEL � o WORK � 04 181 W . Meadow Drive 9 WORK 104 _ , � -o�� EAST 1 1 WAITING 100 12 WAITING 100 13 WAITING 100 14 WAITING 100 Vail Colorado A2.0 1 /4" = 1 ' -0 " NORTH ' A2 .0 1 /4" = 1 ' -0 SOUTH A2.0 1 /4" = 1 ' -0 WEST A2 .0 1 /4' A2 0 1 4 _ � ' - 0" WEST A7. 1 1 /4" = 1 '-0" NORTH 81657 2'-8" 2'-8" 2'-8" 2}" 2}" � � P,� SCHEDULES , DETAILS , AND INTERIOR ELEVATIONS a op N � I � N ,...._ -............_. ..._ DATE 2 APRIL 2007 �o - DRAWN BY CD i - - _ N CHK 'D BY SN 1 '-6" 1 ' -6" 3'-8" 1 '-6" M�DEL FILE AO- 2 .dwg �� ��' COPYRIGHT 2007 BY DAVIS PAR7NERSNIP P.C., MCHITECTS ��-5� SHEET NUMBER: 15 SPC 102 A2 . 0 A7 . 1 1 /4" = 1 ' -0" NORTH D . P.A. PROJECT # 06938.00 HVAC LEGEND GENERAL LEGEND (NOt df q+nbob tt�E�Q bsfow m� uaM a lhne Emwtnqs} (Not olf qmbds Itsbd bNew are uwL on fhw EnMfnp�j FIRE PROTECTION NOTES . ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION HWS - HWS - HEAIING WA7ER SUPPLY � � x SUPPLY WCT UP / SUPPLY DUCT DOWN SECIION DESIGNATION 7 CAP FND OF PIPE , i • Ek1END EXISTING FIRE PR0IECTION SYSTEM TO PROVIDE A COMPLEiE SYSIEM FOR AREA OF WORK. HWR -- HNR -- HEATNG WA1ER RENRN PIPING � � � REiURN/EXHAUST DUCT UP / RENRN/IXHAUST DUCT DONN X SEC11d1 DRANN ON 1HIS SHEET %X PITCH DOWN IN DIREC710N OF ARROW i 2 . FURNISH ALL LABOR, MATERIALS, EOUIPMENT AND SERVICES NECESSARY FOR HTWS - H1W5 - HIGH TEAIPERANRE HOT WATQt SUPPLY � � RWND WCT UP / RWND DUCT DONN x x.x ��� WT ON 1MI5 SHEEf jE �� u+cxa< } iHE INSTALLA110N OF COMPLEIE AND PROPERLY FUNCiIONING fIRE • � � Archit l.S PROTECTION SYSIEM. HTNR -- HTNR -- XIGX TEMPERANRE NOT WATER RENRN 48F12 � INDICATES MT OVAL DUCTWdiK x PoSER DIAGRAAI NUMBEA = PIPE AIJGNMENT CUIDE 3 . ALL FIRE PROTECTION SYSiEMS INSTALLED SHALL BE IN ACCORDANCE WITH CWS - CNS - CXILLED WAIER SUPPLY PIPINC �� Fl.E%IBLE DUCT CONNECTON M"x SHEFf RISER IS DItAWN ON -�- uniar at fuNC� NFPA-13, 14, 20, ETC. AND LOCAL BUILDING CODES AND ORDINANCES. CWR -- CNR -- CHILIED WATER RENRN PoPING BDD � BACKDRAFT DAMPER UNI ECUIPIIENT UNIT IDENTIFlCA110N t CONCENiRIC PIPE REWCER 4 . FIRE PROlECT10N CONTRACTOR SHALL COORDINAiE THE LOCATION OF ALL NEW D - 0 - COOLING COIL DRNN PAN PIPING rc0 � IEMP, CONTROL DAMPER-OPPOSED BLADE � EpUIPNENT UNIT NUMBER rt- ECCfTliRIC PIPE RmUCER FIRE PROiECTION E�UIPMENT AND PIPING NA1H ALL OTHER TRADES PRIOR TO SUBMITTAL OF SHOP DRANANGS AND SYSTEM INSTALLATION, SO AS NOT TO C - C - CONDENSER WATER SUPPLY PIPING TCD � 7EMP. CON7Fi0L DAMPER-PARALLEL BUDE DIFFVSER IDENTFlCAiION pftV -�1� PRESSURE RmUCING VALYE INiERFERE WIiH THE ROUi1NG OF NEW DUCTWORK, PLUMBING PIPING, ETC. NECK X � DIfFVSER NECK pIAAlE7ER 2301 BLAKE ST. , STE. #100 5 . PROVIDE ALL FI171NGS, RISER NIPPLES, ARM-OVERS, HANGERS, ETC. TO CR -- CR -- CONDENSER WATER REIURN PIPING �a�r+ vnn� scR�n DIFFUSER CFM Prnv �_ PftESSURE AND/pt IEMPFRANRE RELIEF VALVE DENVER, COLORADO 80205 MAINTAIN CONFORMANCE WITH APPLICABLE STANDARDS AND TO POSITION THE �ps _ �ps _ OW'r,P�RESSURE S1EAM SUPPLY PoPING yw �� MANUAL VOLUME DAAIPER (e) oasnNC -� PLUC VALYE 303.861 .8555 F.303.861 .3027 SPRINKLER HEADS IN THE PROPER LOCAi10NS. LPC -- IPC -- lAW PRESSURE CONDFNSATE RENRN PIPING MOTIXt OPERATED DAMPER (N) NEW GV �� GATE VALVE EDWARDS CO ORADOI816321 6 . SEAL ALL PIPE PENEiF2AT10NS iHROUGH FIRE RAiED WALLS AND CEILINGS AImIUM PftESSURE STEAAI SUPPLY PIPING M7TH APPROVED FlRE PROOF MAiERIALS AS REQUIRED. i,ws - �5 - ��e�,80� �g- saiN-iN FlrnNC x�n+ Mw (R) rse�oca�rm .� YERiiCAL PME VALYE 970.926.8960 F.970.926.8961 7 . FOR REMODEL AREAS NEW SPRINKLER HEADS SHALL MATCH EXISTING MPC -- MPC -- MmIUM PRESSURE CONDENSAIE REIURN PIPINC �o Q DUCT FlRE DAMPER (� FUIURE av MI aoee vuv� SPRINKLERS. HICH PRESSURE STEAAI SUPPLY PIPINC XPS - XPS - �8���,�en FSD � CdABINAl10N DUCT SMOKE k FlRE DAMPER � POINT OF CANNECiION, NEW TO E70511NC BFV �� BUT7ERFLY VALVE 8 • PROVIDE FIELD COORDINAiION OF PIPING AND SPRINKLER HEAD INSTALLAT10N5 WITH EXISTING DUCTWORK, LIGHTS, SMOKE DE7EC70RS, DIFFUSERS, ETC. HPC -- HPC -- XICH PRESSURE CONDENSAIE RETURN PIPINC SD � DUCT SMOKE DAMPER � DIREC110N OF FlAW IN PIPE BV I}I BALL VALYE 9 . THIS CONIF2ACTOR IS RESPONSIBLE FOR FIELD VERIFICA110N OF ALL EXISIING PC - PC - PUMPED CONDENSA7E PIPING � DUCT SMOKE DETECTOR � DUCiNORK, PoPING AND EWIPMENT TO BE REMOYED CV -1�- CXECK VAL�E CONDITIONS PRIOR TO PURCHASE OF ANY MAiERIALS AND 1HE �--; COMMENCEMENT OF ANY WORK. CONTRACTOR SHALL N071FY THE ARCHI7ECT 88D - BBD - BqLQi BLONDOWN PIPINC DAD ,`�_ � DUCT ACCESS DOOR oin � oia�Ehft -�- so�trao vu� OF ANY DISCREPANCIES FOR RESOLU110N. BF - BF - ea�t �EO w�7eR aiaiNC ` WAD wnu nccess o0at -�- BUTIERFLY Sq.EN01D VALVE NRNINC VANES IN DUCT EL80W RL - RL - REFRIGQtANT L1WID PIPING NIC NOT IN CONTRACT �j� HOSE ENO DRAIN VALVE RS -- RS -- REFftICQ2ANT SUCTON PIPINC EP � ELECTRIC-PNEUMA7IC CONTROL VALVE AFF ABOVE FlNISHED FLOOR P/T T ^/� PRESSURE/IEMPERAIURE TAP RHC - RHG - REFFtICQtANT HOT GAS PIPING PE � PNEUMAIIC-ELECTRIC CANTROL SNITCH GC GENERAL CON7RACTOfi -��- SIRAINER � 1EMPERAIURE SENSOR MC MECHANICAL CONTRACTOR �- S7RAINER W/ BLONDONN TT �n 1HERMOSTA7IC S7EAA1 TRAP O7 WALL MWN7ED iHERMOSTAT EC FIECTRICAL CONTRACTOR � Fl.EXIBLE PIPE CONNECTOR FkT �F�T FLOAT AND TIiERMOSTATC S1EAM IRAP � UNIT MOUNTED TXERMOSTAT TCC TEMPERATURE CAN7ROL CONiRACTOR _ n� iMERMOAIETER 18T 0�� INVERTED BUdCET STEAM TRAP Q HUMIDISTAT KEC KITCHEN EWIPdENT CONiRACTOR � PRESSl1RE GAUCE (' TCV -r--Rr (2 OR 3-WAI� TEMPERANRE CONTROL VAL�E �}-� UNDFRCUT DOOR C COMMON �- 9piT GLA55 C .`� I OR, RI..I � I :� CI ,� �S��II � 1 FS, C��. �--• COXSUiTiKC; At�( 'I I;\XIC:41 'PI iCTRiC:AI. Pti( ;IXGGR,� �'J---- VENNRI METER -�-�- LW�ER NC NORMALLY CLOSED C.AP. i`� i i CEILINC ACCE4$ PANEL -"' 1550 Dovar St�oot . S,�ito Tvm . Lakewood, CO 802153132 ---�- CALIBRATFD BAUNCING VAL4E R DUCT RISE NO NORMALLY OPFN � pUA1p 303232�fi2UG . Fax 3U3;233-3701 RSV �- REFRIGERANT SERNCE VALVE D DUCT DROP TB -� 1FiRUST BLOdC ��aLdcatu��iuma.wn•� . wvrn�.caturrmriu coni DPS -�- DIFFERENIIAL PRES9IRE S'MTCN AL ACAUSi1CALLY LJNm DUCTYpRK ISSUE/REVISION DATE NO. MAV � MANUAL NR VFNT TCOAD lEA1PERANRE CONTROL WTSIDE AIR DAMPQt AAV � AUTdAATIC NR �ENT TCRAD IEIAPERANRE CONTROL RETURN AIR DAAIPER DO U B LE/S I N G LE LI N E D U CT LEG E N D TOV CODE REVIEW F)-0� -07 FS y _ FLOW SYATCH TCEAD IEMPERANRE CONTROL EXFiAUST AIR DAMPER (NOt oli spnbde IlcteE bMOw ors ussE an these enwMq�) T SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE SINGLE LINE DOUBLE LINE EJ O EXPANSION JOINT SP IN NC STATIC PRESSURE IN INCNES WATER COLUMN � RIGID � � � � BJ ��- BALL JOINT EXPANSION CONPENSANR SO Q SUPPLY AIR DENCE � �� � SEE DUCT "' '" RG � RETURN/DWAUST AIR DENCE TNfE-OFF DEfNL �� 45• TEE Ol1ND1 90' TEE lRECTANGl1L1R1 �oc oucr g0' RAdLC_ ELR Y�-_..-. CNS�CNR/HWS,MWR -r-E � � � � SUPPLY d REIURN BRANCH� �,_� � � 7��� � � PIPING TO TERMINAL UNIT '., 45' 1EE (RECTANWLARI 90 TFE (RWNOI N0.kLAL VOWME DAUpER g0 EL9 � .� T � `VOLUME 0.0MP� � � //I Y P L U M B I N G L E G E N D Dl1CT SPL1T � � 45• ELB (NO! all symbols lisled EeloM ars used m thns Erawinqs) ABBR, SYMBOL DESCRIPTiON ABBR. SYMBOL DESCRIPTION CW - - - DOMESTIC CdD WATER PIPINC SCO � SURFACE q.EANWT °u HW - - - - DOMESTICHOTWATERPIPING F� Qi ROORCLEiWWT LABORATORY/ MEDICAL SERVICES LEGEND � (NOt oll yenbds IbbE Odor aro uwtl on Nsu Erawinqa) • � HWC - - - - - DqAESTIC HOT WA7ER qRC. PIPING wco o-n wui ct.�NOUT ABBR. SYMBOL DESCRIPTION ABBR. SYMBOL DESCRIPTION C-SW - - -SW- SOFfENED DOMESIIC COLD WAIER PIPINC CAT O-i CLEANOUT TEE pp - pp - pXy�11 ppNC T 0%YDFN SERNCE W7LET Z� • • H-SW - - - -S1Y- SOF7ENED DOME571C HOT WATER PIPING LCO � L1NE CLEANOUT y� - y/� - yACUUN PIPNIG T VAqJUN SERNCE INIET .� �� �{Y 740' HW - - - - 110'- DOMESTIC HOT WAIER PIPINC O IEMPEftAIURE SXONN OC- FlXNRE OR DFtAIN P-iRM N2p - NYO - NI7RWS ObDE PPINC p NA51E AIESiNESA CAS q�O51iL INLET � Y 3 •. `��V V """ """ ' VENT PIPING AD • AREA DRAIN N - N - lM1ROGEN R%NO T MiRWS WOOE SERNCE W7LET �~� AV - AV - ApD RESISTANT �E?1T PIPING FD � FLODR DRNN (RWND GRATE) MA - YA - NEdCAI NR PIPING 4 NI1ROf.Y'F711 SERNCE W7LET ��� W - W - WASTE PIPINC (ABOVE FLOOR IN BUILDINC) FS � FLOOR SINK (SOUARE GRATE) � - �pp - �qgpr DIOfODE ? NANRAL GAS SERNCE WTLET W -- W -- WASTE PIPINC (BFLOW FLOIXt IN BUILDING) RD/OD � ROOF ORAIN OR OVERFLOW DRAIN WACD -WACD - WA57E ANESIHRIA GAS qSPOSAL Q UBORAIORY/NEqCAL AIR SERNCE WTL.ET AW - AW - AqD RESISTANT WASTE PIPINC (ABOVE FLOOR IN BUILDINC) � CAS PRESSURE RmUCINC VALVE q - q - pppNlgD WAIER %PINC Q CARBON DI070DE �tNCE W7IET CO M B U ST I O N A I R CA L C U LAT I O N ^W - AW AqD RESISiANT WASIE PIPINC (BELOW FLOOR IN BUIIDING) VH J� ATMOSPHERIC VAWUM BREAKER H - H - HYDROOFN RPINC ZV9 � 20NE VAL�E BO% GD - GO - IXtEASE ORAIN (WAS1E LINE TO GREASE INTERCEPTOR) RPBFP -� REDUCEO PRESSURE BACICfLOW PREYENTER ry� - NL - 11qUID NI7ROCFN PIPING MGO NEdCAL CA4 W7lET EXISTING LOUVERS - 2�� 36/36 W/ 60% FREE AREA, GIVES 5.4 FT' EACH LOUVER � � � IW - IW - INDIRECT WA51E PIPINC BFP -iV-T�H DWBLE CFiECK BAqCROW PREVENIER u - u - ugpp�TpqY COYPRESSED AIR PIPINO NGP �q NiEA ALMN PANEL COMBUSTION AIR BASED ON STOICHIOMETRIC COMBUSTION = 1 FTa GAS = 9,3 FT� AIR 5 -- 5 -- SANITAftY SEWER PIPoNG (OUTSIDE BUILDINC) s� �_ sHOac uirtesroR w�sounorr vw� G - C - NANRAL GAS RPMC wcr � YASiER AURN PANEl TWO EXISTING BOILERS � 30HP EACH = 2500 FT'/HR TOTAL ST -- ST -- STIXtM SEIVER PIPINC (BELOW GRADE WTSIDE BUILDING) GC ---i-- G�S 9iUT-OFF VALVE V ail AIR REQUIRED = THEORETICALCOMBUSTION + 50% VENTILATION SSD -- SSD -- SUB-SURFACE DfiNN PIPING V�1 STOP AND DftAIN VAIVE SD - SD - S70RM DRAIN PIPING (ABO�E FLOOR IN BUILDINC) � *' w� H��T Valley AIR REQUIRED FOR EXISTING 30HP BOILERS = gp -- SD -- STIX2M ORAN PIPINC (BELOW FLOOR IN BUILDINC) HB �-- XOSE BIBB _ [2500FT /HR x 1H/60MIN x 9, 3FT J x 1 .5 AIR = 581 CFM OD - OD - O�ERFLOW pRAIN PIPING (ABO�E FLOOFt IN BUIIDING) YH � YAFtD HYDRANT VELOCITY THROUGH LOUVER AT 250 FPM OD -- OD -- OVERFlAW DRAIN PIPING (B0.0W fL00R IN BUIIDING) MH MANHOLE Medical REQUIRED OPENING = 581 CFM / 250 FPM = 2,33 FT�, WiTH TWO OPENINGS @ 1 17 FT° EACH A - � - Co�ePRasm AIR d C�Si iRON G - G - NANRAL CAS PIPING VCP VIIRIFlED CLAY PIPE C e n te r BY ADDING ADDITIONAL 30 HP BOILER WE NEED ADDITIONAL AIR = _ [1250FT'/HR x 1 H/60MIN x 9.3FT'] x 1 .5 CB CATCH BA9N AIR = 291 CFM viR veNT iHRU RooF REQUIRED OPENING = 291 CFM / 250 FPM = t164 FT', WITH TWO OPENWGS @ 0.58 FT� EACH � iNVear pEVAnaw PVC POLIMNYL CHLORIDE WITH ALL THREE BOILERS IN OPERATION WE NEED = 1 , 17 FT' + 0, 58 FT' = 175 FT' PER OPENING AND WE HAVE 5.4 FT' PER OPENING. BOILER BURNER SCHEDULE FAN SCHEDULE First Floor MBH MBH GROSS STEAM ' WHEEL CFM S.P. ', TIP OUTLET ', ' VIBRATION ' APPROX. ARRANGE. , DESIG. MFR. MODEL LOCATION INPUT OUTPUT ' BOILER OUTPUT CONTROL ' REMARKS � NUCIG � 1 M �i � ICII IG AT S.L. AT S.L. HORSEPOWER LBSIHR DESIG. MFR. MODEL FAN TYPE SERVICE , DIA. AT IN. W.C. APPROX. SPEED VELOCITY ' MIN. ISOLATOR ' DRIVE ', DAMPER , THROAT 8 CONTROL ' REMARKS SB-9 HURST BOILER �� 4VT SERIES �- BOILER ROOM � 1265 '' 1004 30 , 1035 SEE SPEC. 1 � �� � p �, 1 ,150 � ; R�M� 5FP 4) '� (FPM) HP i TYPE �� TYPE i, TYPE DIM. ''� _ . .... .. . . _. _ . ._ . . _ . _. . ._ ._ .. ,I -..''r _ ir-. .. . Ef-1 - GREENHECK BSQ-100-3 ._ INLINE i� NUCMEDI ('NCHES) 8500' AT8600' �' - 876 �,� 1l3 i, SPRING . B OBD 14 ' MOUNTIN6 . � � � � � � O � � I I . . �_... .. � -� -r I . , , _. .. .. ... _ .. . ... .. . SEE SPEC , I '� � � ' I� I� I�I S�..ARKS . i i j � I . I � � I . _..._..---........------- 1. PROVIDE STOP CHECK VALVE ON STEAM OUTLET. 5556-, 181 W . Meadow Drive 3129/2007 935 P�,\WMC\2006-367 Nuclear Medicine Remotlel\Cad\Mech\MSChedules\[M-2006-367,x1s]5650-1 Fan Vail , Colorado LOUVER SCHEDULE AIR DEVICE SCHEDULE 81657 ' '_. . ..-- -. �.. _ .. FREE . AIR AP i ''� ' . � �, � � DESIG. MFR. � MODEL � . AREA '� IN W.C. �, CFM I FRAME �, FINISH �� REMARKS DESIG. �, MFR. TYPE MODEL '� FRAME � MATERIAL � FINISH ��. DAMPER � ACCESS. REMARKS LENGTH I HEIGHT ! DEPTH '� SF � AT S.L. STYLE ' i TYPE L-1 I GREENHECK ESD-603 ' 22 22 I 6 1 .46 0.096 . 1150 FLANGE MILL 1 A TITUS CEILING SUPPLY TMS LAY-IN SEE DRAWING WHITE �. -- �� -- I� 24X24 FACE _.. ..- --- ' -----. .. ...----. ....._ . . . . . _. _ . ._ . . .. _. .. .. ..- --. . .. -- -... .... _ .. . . .- � - ------ ... ..---s.. .. .� . . . . . . . . . . �,� . ; ��,� , � I B ! TfTUS ` CEILING SUPPLY I TMS ' LAY-IN j SEE ORAWING I' WHITE -- -• j 24X1Z FACE i . ' � _. � .. ._. .. . .... _ .�-_... .... , . . RE'"'°RKS: ' MECHANICAL LEGEND 1 . PROVIDE BIRD SCREEN MOUNTED IN FRAME ON INSIDE OF LOUVER. C TITUS CEILING EXHAUST PAR '�. LAY-IN �, SEE DRAWING ' WHITE ! -- -- I 24X24 FACE .. ,CEILING EXHAUSTI . .. . � . . ...� .._. . ... - .- . -.-- �,`--.... _ . 3/29I2007 9:35 P'.\WMC12006-367 Nuclear Medicine Remodel\Cad\MechlMSChedules\�M-2006-367,x1s]5932-3 Louver D , TITUS , PAR LAY-IN SEE DR.4WING WHITE -• � -- ! 24X12 FACE AND SCHEDULES __ . __ ... . ..._ _ . ._..-_. .. . --.. . ._- . ... __' ..... ... . � _... .. �. . ....- . ..._ . .. ...._ . ... i � ' '' ', .. '�. DATE 2 APRIL 2007 DRAWN BY Mw� 3/29/2007 9'.35 P:\WMC\2006�367 Nucla�r Medicine Remodel\CedlMech\Mschedules\�M-2006-367,z1s]5932-1 Air Dvc CHK'D BY WAT SHEEf FILE P-SPEC COPYRIOHT 20D6 BY DAVIS PARINERSHIP P.C., ARCHRECIS SMEET NUMBER: M1 . 01 Cator, Ruma & Assoa FILENAME: P: VVMC 2006-367 NUCLEAR MEDICINE REMODEL CAD MECH P-MLSS.DWG _ M1 .01 PLOT: 05 31 2007 � 9: i5am REV: O5 31 2007 CAD: MJohnson XREF: tb.dwg SECTION 15010 - GENERAL PROVISIONS C. SY3TEM TESTS CHICAGO FAUCET N0. 785 OR EOUIVALENT BY APPROVED MANUFACTURER. 8. CONSTRUCTION: ALL STACKS AND BREECHINGS WILL HAVE INNER WALLS OF 20 GA. TYPE B. PROVIDE NECESSARY MATERIALS AND FIELD WORK NECESSARY TO CONNECT CONTROL 1 . HYDROSTATIC TEST: THE TEST SHALL BE ACCOMPLISHED BY HAND PUMPING THE 3-1/21NCH DIAMETER DRAIN FITTING WITH 1-1/21NCH /STAINLESS STEEL TPJLPIECE. 304 STAINLESS STEEL. THE OUTER JACKET SHALL BE 24 GA, ALUMINUM COATED STEEL COMPONENTS FACTORY SUPPLIED AS PART OF EQUIPMENT CONTROLLED, UNLESS 1 .1 GENERAL: 3YSTEM TO THE SPECIFIED WATER PRESSURE, AND MAINTAINING THAT PRE3SURE FOR SIZES UP TO 24' I.D. AND 20 GA. FOR SIZES I.D. AND LARGER. THERE 3HALL BE A SPECIFIED OTHERWI8E. UNTIL THE ENTIRE SYSTEM HAS BEEN INSPECTED FOR LEAK3, BUT IN NO CASE FOR MINIMUM 1' AIR SPACE BETWEEN THE INNER AND OUTER WALLS. A. ALL BIDDERS SHALL BECOME FAMILIAR WITH SITE CONDITIONS PRIOR TO SUBMITTING A TIME PERIOD OF LESS THAN FOUR HOURS. END OF SECTION 15440 C. EXTEND EXISTING DDC CONTROLS UTILIZING HARDWARE AND SOFTWARE COMPATIBLE , BIDS. C. ACCESSORIES: UL LABELED TEES, ELBOWS, INCREASERS, DRAFT HOOD CONNECTORS, WITH CURRENT SYSTEM. PROVIDE FIELD CONTROL PANELS, INPUT/OUTPUT CARDS, . a. HYDRONIC AND DOMESTIC WATER SYSTEMS: 100 PSIG TEST PRESSURE. METAL CAP WITH BIRD BARRIER, ADJUSTABLE ROOF FLASHING, STORM COLLAR, APPLICATION SPECIFIC CONTROLLERS, UW CABLING AND ROUTERS AND OTHER B. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH LOCAL AND STATE CODES. SECTION 15556 � BOILERS SUPPORT ASSEMBLY, THIMBLES, FIRE STOP SPACERS, AND FASTENERS FABRICATED OF COMPONENTS AS REQUIRED TO PROVIDE A CAMPLETE SYSTEM. PERFORM ALL END OF SECTION SIMILP.R MATERIALS AND DESIGNS AS STRAIGHT SECTIONS. PROGRAMMING AND MODIFY GRAPHICAL USER INTERFACE AS RE�UIRED BY THIS WORK. � . � � Arc h i t �S C. EQUIPMENT SCHEDULES ESTABLISH A OUALITY AND DESIGN STANDARD. SUBSTITUTIONS 1 .4 DE3CRIPTION OF WORK: MUST BE E�UIVALENT IN PERFORMANCE, MATERIAL, SPACE, AND CONFIOURATION END OF SECTION END OF SECTION REQUIREMENTS. THE PROJECT ENGINEER OR ARCHITECT'S DECISION WILL BE FINAL SECTION 15100 - VALVES A. EXTENT OF BOILER WORK REQUIRED BY THIS SECTION IS INDICATED ON DRAWINGS AND AND MAY BE BASED ON BOTH CERTIFIED TEST DATA AND SUBJECTIVE REASONING. SCHEDULES, AND BY RE�UiREMENTS OF THIS SECTION. . 1 .1 GENERAL: SECTION 15851 - EXHAUST FANS SECTION 15991 - TESTING AND BALANCING 1 .2 EXAMINATION OF BIDDING DOCUMENTS: B. REFER TO DIVISION 3 FOR CONCRETE PADS; NOT WORK OF THIS SECTION. A. ALL MECHANICAL COMPONENTS SHALL BE PROVIDED WITH VALVES AND UNIONS FOR 1 .1 MANUFACTURER3: A. EXAMINE THE BIDDING DOCUMENTS CAREFULLY, NOT LATER THAN SEVEN DAYS PRIOR SERVICES AND REMOVAL. C. REFER TO OTHER DIVISION 15 SECTIONS FOR PIPING, SPECIALTIES, WATER TREATMENT, 1 .1 DESCRIPTION OF WORK TO THE DATE OF RECEIPT OF BID3. WRITTEN REQUEST FOR INTERPRETATIONS OR PUMPS, BREECHINGS, TEMPERATURE CONTROL3, ETC., REQUIRED EXTERNAL TO A. LOREN COOK CORRECTIONS OF ANY PERCEIVED DISCREPANCIES, AMBI6UITIES, INCONSISTENCIES, OR B. ALL VALVES SHALL COMPLY WITH MSS SP-02, MSS VALVE USER GUIDE. BOILERS FOR INSTALLATION; NOT WORK OF THIS SECTION. B. CARNE3 A. THIS SECTION COVER3 TESTINO AND BALANCING OF ENVIRONMENTAL SYSTEMS ERRORS DISCOVERED 3HALl 9E SUBMITTED TO THE ARCHITECT. ANY INTERPRETATION C. PENN VENTILATOR INCLUDING BUT NQT LIMITED TO AIR DISTRIBUTION SYSTEM3, HYDRONIC �ISTRIBUTION 2301 BLAKE ST. , STE. #100 OR CORRECTION WILL BE ISSUED AS AN ADDENDUM BY THE ARCHITECT. ONLY A C. PROVIDE STEM EXTENSION3 FOR INSULATED SYSTEMS. D. ELECTRICAL WORK: REFER TO DIVISION715 SECTION "ELECTRICAL PROVISIONS OF D. GREENHECK SYSTEMS, AND THE EQUIPMENT AND APPAR4TUS CONNECTED THERETO. DENVER, COLORADO 80205 WRITTEN INTERPRETATION OR CORRECTION 8Y ADDENDUM SHALL BE BINDING. NO MECHANICAL WORK' FOR REQUIREMENTS. E. ACME BIDDER SHALL RELY UPON INTERPRETATIONS OR CORRECTIONS GNEN BY ANY OTHER 1 •2 PRODUCTS: 303.861 .6555 F. . 1 . 027 1 .2 QUALIFICATIONS OF CONTRACTOR METHOD. IF DISCREPANCIES, AMBIGUITIES, INCON313TENCIES, OR ERRORS ARE NOT E. ELECTRICAL WORK: PROVIDE THE FOLLOWING WIRING AS WORK OF THIS SECTION, IN 1 .2 INLINE CENTRIFUGAL FANS: 0225 MAIN STREET . UNIT C101 COVERED BY ADDENDUM OR WRITTEN DIRECTIVE, INCLUDE IN THE BID LABOR, A• BALL VALVES 2' AND SMALLER: ANSI B16.34, CLASS 150 WSP, BOO WOG, RATED FOR 150 ACCORDANCE WITH REQUIREMENTS OF DIVISION 18: A. THE CANTRACTOR SHALL PROCURE THE SERVICES OF AN AABC OR NEBB CERTIFIED, EDWARDS , COLORADO 81632 MATERIALS, AND METHODS OF CONSTRUCTION RESULTIN(3 IN HIGHER COST. AFfER PSI AT 3500F. TWO PIECE END ENTRY BODY 3TYLE, BRONZE BODY CONFORMING TO D. GENERAL DESCRIPTION: INLINE, BELT7DRIVEN, CENTRIFUGAL FANS CON313TING OF INDEPENDENT TESTINO AND BALANCING AGENCY SPECIALIZINO IN THE TESTING, 970.926.8960 F,970.926.8961 AWARD OF CONTRACT, NO ALLOWANCE OR EXTRA COMPENSATION WILL BE MADE DUE ASTM B584, SINGLE FULL PORT, STAINLESS STEEL BALL AND STEM OF ASTM A276 TYPE t . FURNISH TO ELECTRICAL INSTALLER, BURNER EMERGENCY SHUTOFF SWITCH. HOUSING, WHEEL, OUTLET GUIDE VANES, FAN SHAFf, BEARINGS, DRIVE ASSEMBLY, ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS TO PERFORM THE ABOVE TO FAILURE OF MAKING THE WRITTEN REQUESTS AS DESCRIBED ABOVE. 318, 15% OLASS REINFORCED PTFE SEATS, PTFE PACKING AND BLOW OUT PROOF STEM, MOTOR AND DISCONNECT SWITCH, MOUNTING BRACKETS, AND ACCESSORIES. MENTIONED WORK. VINYL COATED STEEL HANDLE. 2. PROVIDE CONTROL WIRING BETWEEN BOILER CONTROL PANEL AND THERMOSTATS, B. BE RESPONSIBLE FOR ITS PROMPT DELIVER OF REQUEST. FAILURE TO 30 RE�UEST A�UASTATS, PRESSURESTATS, OR ANY OTHER CONTROL DEVICE. E. HOUSING: SPLIT, SPUN�ALUMINUM HOUSING, WITH ALUMINUM STRAIGHTENING VANES, � ,3 CODES AND STANDARDS CLARIFICATION OF ANY INADEQUACY, OMISSION, OR CONFLICT WILL NOT RELIEVE MANUFACTURERS: CONBRACO (APOLLO), CRANE, STOCKHAM, NIBCO. INLET AND OUTLET FLANGES, AND SUPPORT BRACKET ADAPTABLE TO FLOOR, SIDE RESPON3IBILITY OF DOING S0. THE SIGNING OF THE CONTRACT WILL BE CONSIDERED 3. PROVIDE FACTORYOMOUNTED AND WIRED CONTROLS AND ELECTRICAL DEVICES W��� OR CEILING MOUNTING. A. NEBB: "PROCEDURAL 3TANDARDS FOR TE3TING, ADJU3TING, AND BALANCING OF AS IMPLICITLY DENOTING A THROUGH COMPREHENSION OF THE FULL INTENT AND B• BUTTERFLY VALVE3 2-112' AND LARGER: MSS SP$7, CAST-IRON BODY CONFORMING TO AS SPECIFIED IN THIS SECTION. ENVIRONMENTAL SYSTEMS." SCOPE OF THE WORKING DRAWINGS AND SPECIFICATIONS. 31GNING OF THE CONTRACT ASTM A125 CLASS B, ALUMINUM BRONZE ASTM 8148 DISC, ONE-PIECE 316 STAINLESS F. BELTCDRIVE UNITS: MOTOR MOUNTED ON ADJUSTABLE BASE, WITH ADJUSTABLE INDICATES AGREEMENT TO ALL OF THE CONDITIONS IN THIS SPECIFICATION. STEEL STEM, EPDM SEAT, BRONZE BEARINOS, NON-METALLIC BUSHIN6 AND STEM SEAL, F. REFER TO DIVISION718 SECTIONS FOR OTHER ELECTRICAL WORK INCLUDING MOTOR SHEAVES, ENCL03URE AROUND BELTS WITHIN FAN HOUSING, AND LUBRICATING TUBES B. ASHRAE: ASHRAE HANDBOOK, 1987 SYSTEMS VOLUME, CHAPTER 57, TESTING, AN31 CLASS 125 FLANGE 3TANDARD, RATED FOR 200 PSI DROP-TIGHT SHUT OFF DEAD 3TARTERS, DISCONNECT3, WIRES/CABLES, R4CEWAYS, AND OTHER REQUIRED PROM FAN BEARINGS EXTENDED TO OUTSIDE OF FAN HOUSING. ADJU3TING, AND BALANC�NO. � 1 .3 MECHANICAL INSTALLATIONS: END SERVICE, WITH DOWNSTREAM FLANGE REMOVED. PROVIDE EXTENDED NECK FOR 2' ELECTRICAL DEVICES; NOT WORK OF THIS SECTION. THICK INSULATION. ALL VALVES SHALL BE FACTORY TESTED TO 110% OF PRESSURE G. WHEEL: ALUMINUM, AIRFOIL BLADES WELDED TO ALUMINUM HUB. 1 .4 PR0.IECT CONDITIONS A. DRAWINGS ARE DIAGRAMMATIC IN CHARACTER AND DO NOT NECESSARILY INDICATE RATINGS. ALL BUTTERFLY VALVES SHALL BE FULL LUGGED BODY, DRILLED AND TAPPED. � ,5 MANUFACTURERS: EVERY REQUIRED OFFSET, VALVE, FITTING, ETC. H. BEARINGS: GREASE LUBRICATED BALL OR ROLLER ANTI-FRICTION TYPE WITH EXTENDED A. AIR AND WATER TESTING AND BALANCING SHALL NOT BE61N UNTIL THE SYSTEM HAS MANUFACTURER3: KEYSTONE, CENTERLINE, NIBCO. A. MANUFACTURERS: 3UBJECT TO COMPLIANCE WITH RE�UIREMENTS, PROVIDE LUBRICATION LINE3 TO OUTSIDE FAN HOUSING. BEEN COMPLETED AND IS IN FULL WORKING ORDER. B. DO NOT SCALE DRAWING3. VERIFY DIMENSIONS IN FIELD PRIOR TO COMMENCEMENT OF PRODUCTS BY ONE OF THE FOLLOWING: WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. C. STEAM SERVICE BALL VALVES: 250 WSP, 600 WOG RATED FOR 250 PSIG SATURATED I. ACCESSORIES; THE FOLLOWING ACCESSORIES ARE RE�UIRED AS INDICATED: B. PUT ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS AND EOUIPMENT INTO STEAM. TWO PIECE AND ENTRY BODY STYLE, BRONZE BODY CONFORMING TO ASTM 1 . VERTICAL TUBLESS STEAM BOILER FULL OPERATION AND CONTINUE OPERATION OF SAME DURINCa EACH WORKING DAY OF C. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY. WHATEVER IS CALLED FOR IN 8584, 3TANDARD PORT 318 STAINLESS STEEL BALL AND STEM. CARBON M1D GRAPHITE a. HURST BOILER 1 . VOLUME CONTROL DAMPER: MANUAL OPERATED WITH OUADRANT LOCK, LOCATED TESTING AND BALANCING. EITHER IS BINDING AS THOUGH CALLED FOR IN BOTH. REINFORCED PTFE BLOWOUT PROOF STEM, VINYL COVERED 3TEEL HANDLE. THREADED b. LATTNER IN FAN OUTLET. ENDS. APOLL070-140-84 1 .5 TEMPER4TURECONTROLS D. BEFORE ANY WORK IS INSTALLED, DETERMINE THAT EQUIPMENT WILL PROPERLY FIT THE 1 ,6 VERTICAL TUBELESS STEAM BOILERS: 2. COMPANION FLANGES: FOR INLET AND OUTLET DUCT CONNECTIONS. SPACE; THAT REQUIRED PIPING GRADES CAN BE MAINTAINED AND THAT DUCTNORK CAN D. STEAM SERVICE GLOBE VALVES (2 INCHES AND SMALLERj: MSS SPAO, CLASS 150 BODY, A. OPERATE ALL TEMPERATURE CONTROL SYSTEMS WITH THE TEMPERATURE CONTROL BE RUN AS CONTEMPLATED WITHOUT INTERFERENCES BETWEEN SY3TEMS, WITH BONNET, BONNET RING CAST BRONZE ASTM B�2 TYPE 420, STAINLESS STEEL DI3C AND A. BOILER CONSTRUCTION: 3. FAN GUARDS: EXPANDED METAL IN REMOVABLE FRAME. CONTRACTOR'S REPRESENTATIVE FOR PROPER SEQUENCE OF OPERATION AND STRUCTURAL ELEMENTS OR WITH THE WORK OF OTHER TRADES. 3EAT RING, UNION BONNET, NON-ASBESTOS TEFLON IMPREGNATED STEM PACKING, CALIBRATION. REPORT IN WRITING ANY DEFIDCIENCIES TO THE ENGINEER IMMEDIATELY. C /1 E. COORDINATE THE INSTALLATION OF MECHANICAL MATERIALS AND EQUIPMENT WITH ALL COPPERSILICON BRONZE 3TEM, BRASS PACKING GLAND AND MALLEABLE IRON HANDLE. 1 . THE FOUR PAS3 VERTICAL TUBELESS BOILER 13 TO HAVE THE BURNER MOUNTED IN END OF SECTION CA I C) Il, R I, I I��� �'� (J ,'l �SO�. I A 1 F.S, C U. STOCKHAM FIG. B-28 THE CENTER OF THE 801LER AT APPROXIMATELY MID HEIGHT SO AS TO PROVIDE 7 .6 REpUIREMENTS OF WORK TRADES. E. STEM SERVICE GLOBE VALVES (2-1I21NCHES AND LARGER); MSS SP-85, CLA3S 125, CAST FOR EASY ACCESS FOR SERVICING. MOUNTING OF BURNERS AT THE BOTTOM OF COXSiILTiKG MG('I L4\I('AI .'�I.PCTRICAi. PtiG1KLfR.� IRON BODY ASTM A-128, CLASS B, BOLTED BONNET BRONZE MOUNTED, RISING STEM THE BOILER OR FROM THE TOP OF THE BOILER IS NOT ACCEPTABLE. ADEQUATE SECTION 15BB1 0 METAL DUCTWORK A, BALANCINO PROCEDURE SHALL BE IN ACCARDANCE WITH NEBB OR AABC GUIDELINES ± 550 Dover Street . Suita Two . Lakewood, CO 80215�3132 F. COORDINATE THE CUTTINO AND PATCHINO OF BUILDING COMPONENTS TO BRONZE DISC AND SEAT, 03 S Y, NON-ASBEST03 TEFLON IMPREGNATED STEM PACKING HAND HOLE3 MUST NOT BE EXPOSED TO THE FIRE3IDE OF THE BOILER. BOILER FOR PROPORTIONAL BALANCE. SUBMIT REPORT ON STANDARD NEV1/ FORMS OR SUBMIT 303232-620G . Fax 303;2333701 ACCOMMODATE THE INSTALLATION OF MECHANICAL EQUIPMENT AND MATERIAL3. AND CAST IRON OR MALLEABLE IRON HAND WHEEL. STOCKHAM FIG. G-512 WILL MAKE USE OF WELDED CONVECTION FINS TO ENHANCE HEAT TRANSFER AND 1 .1 DESCRIPTION OF WORK: FORMS FOR REVIEW PRIOR TO BALANCING. MEASUREMENTS SHALL INCLUDE ALL cru(r�cuUn�uma con•� . www.c�turr�n•��acom TO DISTRIBUTE THE FLOW OF FLUE 6ASSES. MOTOR AMPERAGE AND YOLTACiE READING3; MOTOR AND FAN RPMS; STATIC PRESSURE G. INSTALL MECHANICAL EQUIPMENT TO FACILITATE MAINTENANCE AND REPAIR OR F. STEAM 3ERVICE BUTTERFLY VALVES 2-1/2 INCH AND LARGER: MSS SP-87 AND SP�B A. EXTERIOR INSULATION OF METAL DUCTWORK IS SPECIFIED IN OTHER DIVISION�15 AT INLET AND OUTLET OF ALL PACKAGED EQUIPMENT, FAN3, COILS, AND FILTER3; PITOT REPLACEMENT OF EQUIPMENT COMPONENTS. A3 MUCH AS PRACTICAL, CONNECT CARBON STEEL ASTM A216WCB BODY, 318 STAINLESS STEEL DISC, 17-4 PH STAINLESS 2. FIRESIDE HEAT EXCHANOE AREAS MUST BE ACCESSIBLE FROM THE TOP AND SECTIONS, AND IS INCLUDED A3 WORK OF THIS SECTION. TUBE MEASUREMENT OF SUPPLY, EXHAUST, RETURN, AND OUTSIDE AIR MAIN DUCTS, AT E�UIPMENT FOR EASE OF DISCONNECTING, WITH MINIMUM OF INTERFERENCE WITH 3TEEL STEM, RTFE SEAT WITH STAINLESS STEEL BACKUP RINO, 318 STAINLESS STEEL BOTfOM OF THE BOILER. REMOVABLE ACCESS PLATES ARE TO BE PROVIDED. MINIMUM OUTSIDE AIR, AND 100% (ECONOMIZERj OUTSIDE AIR; AIR INLET AND OUTLET3; ISSU E/REVISION DATE NO. OTHER IN3TALLATIONS. NITR4TE BUSHING, TFE PACKING, STEAM TRIM ACCESSORIES ANSI CLASS 150 EXTENDED 1 •2 MANUFACTURERS: WATER FLOW ATALL PLOW MEASUREMENT STATIONS; INLET AND OUTLET PRESSURE AT � NECK FOR 2 INCHES THICK INSULATION. ALL VALVES SHALL BE FACTORY TESTED AT 3. THE BOILER FURNACE CROWN 3HALL BE WATER COOLED. THE BURNER SHALL FIRE q. µ�UFACTURERS: SU&IECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PUMPS WITH FLOW CALCULATED FROM THE PUMP CURVE; WATER FLOW, AND PRESSURE TOV CODE REVIEW 6-Ol -O7 H. CONTR4CTOR SHALL BE RESPON3IBLE FOR ALL FEES AND PERMITS. THEIR RATED PRESSURES. ALL BUTTERFLY VALVES SHALL BE FULL LUGOED BODY, INTO THE WATER COOLED FURNACE AND 3HALL NOT PA33 UNDER THE BOTTOM pRODUCTS BY ONE OF THE FOLLOWINO; DROP AT ALL COILS. DRILLED AND TAPPED. KEYSTONE K-LOK SERIES FIG. 362 MUD RING OF THE BOILER. A BOILER BLOWDOWN CONNECTION SHALL BE PROVIDED 1 .4 REMODEL PROJECTS: IN THE BOTTOM OF THE BOILER. THE STEAM CHAMBER SHALL COVER THE ENTIRE B. PROVIDE BELTS AND SHEAVES AS REQUIRED FOR DRIVE CHANGES TO ADJUST FAN G. 3TEAM SERVICE SWING CHECK VALVES2-1/2 INCHES AND SMALLER: MSS SP-80; CLASS TOP OF THE BOILER WITH CONVECTION RODS FOR DRY STEAM DELIVERV. 1 • FLEXIBLE DUCTS: SPEED. A. IN AS MUCH AS DESIGN FOR REMODEL AND/OR REHABILITATION RE�UIRES THAT 125 WSP Z00, CAST BRONZE BODY AND CAP CONFORMING TO ASTM B 82, ASTM B61 FOR CERTAIN ASSUMPTIONS BE MADE REGARDINO EXISTIN6 CONDITIONS, AND BECAUSE 200 BRONZE, HORIZONTAL SWING DESIGN, Y-PATTERN WITH A BRONZE DISC, STAINLE3S 4. BOILER INSULATION 3HALL CONSIST OF A 1 .5" CERAMIC FIBER, RATED FOR 2300 D/F a. FLEXAAASTER C. ADJUST FLOWS TO WITHIN 10% OF REQUIRED QUANTITY. WHERE ROOM AIR PRESSURE SOME OF THESE A33UMPTIONS CANNOT BE VERIFIED WITHOUT DE3TROYING STEEL PIN AND HAVING THREADED OR SOLDER ENDS. CLA33 150 VALVES MEETING THE AND PROVIDING FOR LOW THERMAL CONDUCTIVITY. THE BOILER SHALL BE CLAD b. THERMAFLEX RELATIONSHIPS ARE REQUIRED TO BE MAINTAINED AS SHOWN BY A DIFFERENTIAL OF OTHERWISE ADEQUATE OR SERVICEABLE PORTIONS OF THE BUILDING, THE ENGINEER qBOVE 3PECIFICATION3 MAY BE USED WHERE PRESSURE RE�UIRES OR CLASS 125 ARE WITH 22 GAUGE JACKETING WITH POWDER COAT FINISH IN DEEP BLUE. THE TOP 2, DUCT TAKE OFF FITTINGS SUPPLY AND IXHAUST/RETURN OR BY NOTE, ADJUST SUPPLY TO WITHIN 10% AND THEN CANNOT ASSURE THE OWNER OR THE CONTRACTOR THAT THE PROFESSIONAL NOT AVAILABLE. AND BOTTOM OF THE BOILER'S EXTERIOR SHALL BE FITTED WITH A 3' STAINLE33 ADJUST EXHAU3TIRETURN TO PROVIDE THE INDICATED ROOM PRESSURE. IF ACTUAL CONSULTING SERVICES HEREIN ENCOMPA33 AL CONTINGENCIES. FIELD COORDINATION STEEL BAND. ALL OPENINGS AND PENETRATIONS THROUGH THE BOILER JACKET QUANTITY IS LE33 THAN 90%, INVESTIGATE CAUSE, ATTEMPT TO RECTIFY AND NOTIFY DURING CONSTRUCTION IS IMPERATIVE. NL41(E REA30NABLE ALLOWANCES FOR UNSEEN e. HERCULES INDUSTRIES CONDITION3. H. STEAM SERVICE SWING CHECK VALVES: 2-1/2 TO 3 INCH: MSS SP-71 ; CLASS 125 (CLASS SHALL BE FITTED WITH COVER PLATES AND SECURED BY METAL SCREWS FOR EASE b. FLEXMASTER ENGINEER. SUBMITTAL OF BALANCE REPORT WITH LESS THAN REQUIRED FLOWS 175 FM APPROVED FOR FIRE PROTECTION PIPING 3YSTEMS), CAST IRON BODY AND OF REMOVAL. THE BOILER'S SKIN TEMPERATURE SHALL NOT EXCEED 50(F ABOVE c. THERMAFLEX WITHOUT EXPLANATION 13 CAUSE FOR REJECTION OF REPORT. B. THE EXI3TING BUILDING WILL BE OCCUPIED BY THE OWNER DURING CONSTRUCTION. BOLTED CAP CONFORMING TO A3TM A 128, CLASS B; HORIZONTAL 3WING, WITH A THE AMBIENT TEMPERATURE. d. OMINAIR 1 .7 REPORT OF WORK BRONZE DISC OR CAST IRON DISC WITH BRON2E DISC RING AND FLANGED ENDS. VALVE CONTINUED OPERATION OF THE FACILITY SHALL NOT 8E HINDERED BY THIS WORK. SHALL BE CAPABLE OF BEING REFITTED WHILE THE VALVE REMAINS IN THE LINE. FOR 5. THE ENTIRE BOILER ASSEMBLY SHALL BE ATTACHED TO STRUCTURAL STEEL 3KIDS 1 .3 DUCTWORK MATERWL3: ACCOUNT FOR ALL ADDITIONAL COSTS WHICH MAY 8E INCURRED DUE TO THE gEWAGE EJECTOR AND SUMP PUMP DISCHARGE SWING CHECK VALVES 2-112 INCHES WITH BR4CE TUBING. A LIFfING EYE SHALL BE PROVIDED ON THE TOP OF THE A. THE TESTING 8 BALANCING CONTRACTOR SHALL SUBMIT SIX (6) BOUND COPIES OF THE DIFFICULTY OF WORKING OVER AND AROUND EMPLOYEES, FURNITURE, E�UIPMENT, (WD LARGER, PROVIDE OUTSIDE LEVER WITH WEIGHT OR SPRING TO ASSIST DISC TO BOILER FOR RIGGING. A, SHEET METAL: EXCEPT AS OTHERWISE INDICATED, FABRICATE DUCTWORK FROM FINAL TESTING AND BALANCING REPORT AT LEA3T 15 CALENDAR DAYS PRIOR TO THE ETC.; AND DUE TO THE HOURS OF THE DAY IN WHICH AN AREA MAY BE ACCESSIBLE CLOSE RAPIDLY. GALVANIZED SHEET STEEL COMPLYIN6 WITH ASTM A 527, LOCKFORMING QUALITY; WITH MECHANICAL CONTRACTOR'S REQUEST FOR FINAL OBSERVATION. ALL DATA SHALL BE WHEN COMPILING HIS BID. 8. BOILER SHALL COME COMPLETE WITH A HEATED FEEDWATER TANK, BLOW DOWN G 90 ZINC COATING IN ACCORDANCE WITH ASTM A 525; AND MILL PHOSPHATIZED FOR RECORDED ON APPLICABLE REPORTING FORMS. THE REPORT SHALL INCLUDE ALL END OF 3ECTVON SEPARATOR, AND FEEDWATER PUMP. AlL COMPONENTS SHALL BE MOUNTED ON EXPpSED LOCATIONS. PROVIDE FLAT SEAM CONSTRUCTION WHERE STANDINO SEAMS OPERATINO DATA, A LIST OF ALL EQUIPMENT USED IN THE TESTING ANO BALANCINO C. BE RESPONSIBLE TO FIELD VERIFY EXISTINO EpUIPMENT OR DUCTWORK REMAINING TO THE BOILER SKIDS, AND SHALL BE FACTORY PIPED, REQUIRING ONLY FIELD ARE A HAZARD TO THE OWNER'S OPERATION PERSONNEL. WORK, AND SHALL BE SIGNED BY THE SUPERVISINO EN6INEER AND AFFIXED WITH HIS BE RECONNECTED TO NEW OR EXISTING SYSTEMS. PROVIDE DUCTWORK, PIPING, CONNECTIONS TO FEEDWATER, 3TEAM, BLOW DOWN, VENT, AND RELIEF. CERTIFICADTION SEAL. FINAL ACCEPTANCE OF THI3 PROJECT WILL NOT TAKE PLACE CONTROLS, DIFFUSERS, ETC., AS REQUIRED TO RESTORE CONTINUITY OF SYSTEMS(S), SECTION 15140 - SUPPORTS, ANCHORS AND SEALS 1 .4 MISCELLANEOUS DUCTWORK MATERIALS: UNTIL A SATISFACTORY REPORT IS RECEIVED. OR TO MAKE NEW WORK MEET EXISTING CONDITIONS, WHETHER INDICATED OR NOT. B. BOILER TRIM 1 .1 GENERAL A. FITTINGS� PROVIDE RADIUS T'PE FITTINGS FABRICATED OF MULTIPLE SECTIONS WITH 1 .8 GUARANTEE OF WORK �u����� D. PROVIDE MECHANICAL DEMOLITION RE�UIRED. REFER TO ARCHITECTURAL DEMOLITION 1 . EACH BOILER 3HALL BE FITTED WITH A MCDONNELL 8 MILLER #157 EXTERNAL MAXIMUM 15 DEG. CHANGE OF DIRECTION PER SECTION. UNLESS SPECIFICALLY q, THE TESTING 8 BALANCING CONTR4CTOR SHALL GUARANTEE THE ACCUR4CY OF THE DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. VISIT SITE PRIOR TO A. ALL PIPE HANGERS SHALL BE THREADED ROD WITH CLEVIS OR TRAPEZE SUPPORTS. FLOAT TYPE PRIMARY LOW WATER CUT OFF AND FEEDWATER PUMP CONTROL. THIS DETAILED OTHERWISE, USE 45 DEG. LATERALS AND 45 DEG. ELBOWS FOR BRANCH TESTS AND BALANCE FOR A PERIOD OF 90 DAYS FROM DATE OF FINAL ACCEPTANCE OF � � r BID TO DETERMINE EXTENT OF WORK INVOLVED. EXISTINO FIXTURES, MECHANICAL CONTROL SHALL BE FITTED WITH A WATER COLUMN GAUOE OLASS SET WITH TAKEOFF CONNECTION3. WHERE 90 DEG. BRANCHES ARE INDICATED, PROVIDE CONICAL THE TEST AND BALANCE REPORT. DURING THI3 PERIOD, THE TESTINO 8 BALANCING EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER. DISP03E OF 1 . INSULATED PIPING: COMPLY WITH THE FOLLOWING INSTALLATION REQUIREMENTS. 3AFETY BALL CHECKS AND PROVIDED WITH A PLASTIC GAUGE GLASS PROTECTOR. TYPE TEES. ALL REMOVED PIPING, DUCTWORK, ETC. UNLE33 NOTED OTHERWISE. PROVIDE A t" BALL VALVE FOR WATER COLUMN DRAIN. CONTRACTOR SHALL MAKE PERSONNEL AVAILABLE AT NO CO3T TO THE OWNER TO !!re 2. SHIELD3: PROVIDE PROTECTIVE SHEET SHIELD3, MSS TYPE 40 ON COLD PIPING 2' B. DUCT SEALANT: NON�HARDENING, NON�7MIGRATING MASTIC OR LIQUID ELASTIC CORRECT DEFICIENCIES THAT MAY BECOME APPARENT IN THE SYSTEM BALANCE. � �'O' Z: E. COORDINATE ALL PENETRATIONS OF THE FLOOR SLAB PRIOR TO COMMENCING WORK. AND LESS. SHIELDS 3HALL SPAN AN ARC OF 1B0 DEGREES AND SHALL BE MINIMUM 2. PROVIDE A MCDONNELL 3 MILLER #750 CONDUCTANCE TYPE AUXILIARY LOW SEALANT, TYPE APPLICABLE FOR FABRICATIOW INSTALLATION DETAIL, AS COMPOUNDED = • UTILIZE X-RAY AND VISUAL INVESTIGATION OF EXISTING CONDITIONS AS RE�UIRED 8' LONG, � WATER LEVEL CUT OFF CONTROL WITH MANUAL RESET. PROVIDE LED AND RECOMMENDED BY MANUFACTURER SPECIFICALLY FOR SEALINO JOINTS AND �3 �� PRIOR TO DRILLING OR CUTTING. ANNUNCIATION FOR: A) ON, B) OFF. PROVIDE A TEST SWITCH WITH RED INDICATOR SEAMS IN DUCTWORK. ALL PVC COATED EXHAUST DUCTWORK SHALL BE SEALED WITH END OF SECTION A� g � �•• 3. INSULATION INSERTS: PROVIDE ASBESTOS-FREE CALCIUM SILICATE INSERT LIGHT. AN APPROVED CHEMICAL RESISTANT SEALANT AS MANUFACTURED BY FOREMOST CO. N�N� 1 .5 EXCAVATION AND BACKFILLING: ENCASED WITH A VAPOR BARRIER AND A SHEET METAL SHIELD FOR COLD PIPING 3. PROVIDE A STEAM PRESSURE GAUGE WITH STAINLESS STEEL ENCLOSURE AND PCD NO. 8 DUCT SEALER AND WRAP WITH HARDCAST TAPE. FOR OUTDOOR DUCTWORK, ?� �� 2-112' AND L4RGER. SYPHON AND TEST COCK. PROVIDE A KUNKLE SAFETY RELIEF VALVE SETAT BOILER SEALANT SHALL ALSO BE U.V. RESISTANT AND WEATHER RESISTANT. p� A. CONTACT OWNERS OF ALL UNDERGROUND UTILITIES TO HAVE THEM LOCATED AND DESIGN PRESSURE. MARKED, AT LEAST 2 BUSINESS DAVS BEFORE EXCAVATION IS TO BEGIN. ALSO, PRIOR B. ALL DUCT HANGERS SHALL BE SHEET METAL STRAP OR ANGLE IRON IN COMPLIANCE 4. PROVIDE STEAM PRESSURE CONTROLS FOR SEQUENCE OF OPERATION AS C. DUCIWORK SUPPORT MATERIALS: EXCEPT AS OTHERWISE INDICATED, PROVIDE TO STARTING EXCAVATION BRIEF EMPLOYEES ON MARKING AND COLOR CODES AND WITH SMACNA GUIDELINES. SPECIFIED. IN ADDITION, PROVIDE AN AUXILIARY HIGH LIMIT PRESSURE CONTROL HOT�DIPPED GALVANIZED STEEL FASTENERS, ANCHORS, RODS, STRAPS, TRIM AND TR41N EMPLOYEES ON EXCAVATION AND SAFETY PROCEDURES FOR NATURAL GAS WITH A MANUAL RESET. ANGLES FOR SUPPORT OF DUCTWORK. LINES. WHEN EXCAVATION APPROACHES GAS LINES, EXP03E LINES BY CAREFULLY END OF SECTION 5. PROVIDE FEEDWATER STOP AND CHECK VALVES IN ACCORDANCE WITH A3ME PROBING AND HAND DIGGING. CODE. D. FLEXIBLE DUCTS: FLEXIBLE AIR DUCTS SHALL BE LISTED UNDER UL-161 STANDARDS AS 6. PROVIDE ONE QUICK AND ONE SLOW OPENING BOTTOM BLOVYDOWN VALVES IN CLASS I AIR DUCT MATERIAL AND SHALL COMPLY WITH NFPA STANDARDS 90A AND 90B. B. IN GENERAL, FOILOW ALL REGULATIONS OF OSHAAS SPECIFIED IN PART 1928, SUBPART SECTION 15190 - IDENTIFICATION ACCORDANCE WITH ASME CODE. MINIMUM OPERATING PRESSURE RATING 3HALL BE 8' W.C. THROUGH A TEMPERATURE P, 'EXCAVATIONS, TRENCHING AND SHORING.' FOLLOW SPECIFICATIONS OF DIVISION 15 � � GENERAL C. BURNER EDUIPMENT RANCaE OF -200 TO 1500F; MINIMUM WORKING VELOCITY RATING SHALL BE 4000 F.P.M. AS THEY REFER SPECIFICALLY TO THE MECHANICAL WORK. CONTRACTOR SHALL A33UME RESPONSIBILITY FOR SUPPLYING MATERIAL APPROVED BY 1 . THE FACTORY ASSEMBLED BOILER PACKAGE SHALL INCLUDE A UL LISTED THE AUTHORITY HAVING JURI3DICTION. C. DIO TRENCHES TO DEPTH, WIDTH, CONFIOURATION, AND GRADE APPROPRWTE TO THE A. PROVIDE ADHESIVE BACKED OR PRE-CURLED SNAP-ON LABELS WITH FLOW ARROWS AUTOMATIC BURNER AND CONTROL SYSTEM COMPLYINO WITH ASME CSD-1 . THE PIPINCa BEING INSTALLED. DIG TRENCHES TO 8" BELOW THE LEVEL OF THE BOTTOM OF FOR ALL PIPING. PROVIDE ENGRAVED PLASTIC LAMINATE TAG FOR ALL MAJOR BURNER SHALL BE FITTED ON THE BOILER SUCH THAT COMBUSTION TAKES PLACE FLEXMASTER TYPE SM. THE PIPE TO BE INSTALLED. INSTALL 6' BED OF PEA GR4VEL OR S�UEEGEE, EQUIPMENT (FANS, BOILERS, ETC.) WITHIN THE WATER BACKED FURNACE. MECHANICALLY TAMP TO PROVIDE A FIRM BED FOR PIPING, TRUE TO LINE AND GRADE E. DUCT TAKE OFF PITTINGS TO INDIVIDUAL AIR INLETS 8 OUTLETS: PROVIDE CONICAL WITHOUT IRREGULARITY. PROVIDE DEPRESSIONS ONLY AT HUBS, COUPLINGS, FLANOES, 1 . MANUFACTURERS: ALLEN SYSTEMS, BRADY CO., SETON NAME PLATE. 2. THE BURNER SHALL BE SET UP FOR FIRING OF NATURAL GAS. THE BURNER SPIN-IN FITTINGS AT FLEXIBLE OR ROUND 3HEET METAL DUCT TAKEOFP3. WHERE • OR OTHER NORMAL PIPE PROTRU310N3. ASSEMBLY SHALL INCLUDE THE FUEL TRAINS FOR THE SPECIFIED FUEL. PROVIDE A SPECIFICALLY SHOWN ON DRAWINGS, WHERE THE DUCT DIMENSION DOES NOT ALLOW � � B. LOCATE PIPE LABELS EVERY 25', EXCEPT WHERE CONCEALED ABOVE NON-ACCES3IBLE SOLID STATE FLAME SAFEGUARD. FOR A CONICAL SPIN-IN, OR AT CONTR4CTOR'S OPTION, PROVIDE 45° INLET va, D. BACKFILL TO 12 INCHES ABOVE TOP OF PIPING WITH PEA GRAVEL OR SQUEEGEE, THE CEILINGS OR IN NON-ACCESSIBLE SHAFTS. LOCATE LABELS SO ALL PIPING WITHIN VIEW 3. PROVIDE A BOILER MOUNTED CONTROL PANEL ENCLOSURE FOR THE SPECIFIED RECTANGULAR TO ROUND DUCT TAKE OFF FITfINGS, WITH FACTORY APPLIED GASKET. SAME AS USED FOR PIPING BED, COMPACT PROPERLY. OF AN ACCESS DOOR CAN BE IDENTIFIED. PRESSURE CONTROLS. FITTINGS SHALL INCLUDE BUTTERFLY TYPE MANUAL VOLUME DAMPER WITH REGULATOR, 4. BOILER SEQUENCE OF OPERATION SHALL BE: LOWlHIGH�LOW. AND DUAL LOCKING DEVICE. DUAL LOCKING DEVICE SHALL CONSIST OF TNO SHAFT V al1 e E. CONTINUE BACKFILL TO FINISH GRADE, USING FRIABLE MATERIAL FREE OF ROCK AND END OF SECTION D, OTHER MOUNTED WING NUTS, ONE ON EACH SIDEOF THE DAMPER. WING NUTS 3HALL TIGHTEN V OTHER DEBRIS. INSTALL IN 8 INCH LAYERS, EACH PROPERLY MOISTENED AND 1 . THE BOILER(3) 3HALL BE OUARANTEED BY THE MANUFACTURER TO PROVIDE FOR A ON SHAFTS TO LOCK BUTTERFLY IN PLACE. SHAFTS SHALL BE SOLID METAL, ROLLED �J MECHANICALLY COMPACTED PRIOR TO INSTALLATION OF ENSUING LAYER. COMPACTION FUEL TO STEAM EFFICIENCY OF NOT LESS THAN 80% WITH THE CONDITIONS METAL SHAFTS ARE NOT ACCEPTABLE. � � � � C � � BY HYDR4ULIC JETTING IS NOT PERMISSIBLE. SECTION 15250 - INSULATION PROVIDED. 1 .1 PIPING INSULATION 1 • PROVIDE A FACTORY TEST FIRING OF THE COMPLETED BOILER ASSEMBLY. AN ASME HERCULES MODEL 9000 (CONICAL) F. USE SUITABLE EXCAVATED MATERIAL TO COMPLETE THE BACKFILL, INSTALLED IN 8 INCH MANUFACTURERS DATA REPORT SHALL 8E INCLUDED WITH INSTALLATION, LIFTS AND MECHANICALLY COMOPACTED TO SEAL AGAINST WATER INFILTRATION. OPERATION AND MAINTENANCE MANUAL. PROVIDE A WIRING SCHEMATIC IN THE 1 .5 LOW PRESSURE ROUND DUCTWORK: COMPACT TO 95% FOR THE UPPER 30 INCHES BELOW PAVING AND SLABS AND 90% A• FIBERGLA33 PIPING INSULATION: A3TM C547, CLASS 1 , 'K' FACTOR SHALL BE MAXIMUM BOILER CANTROL PANEL. � e n te r ELSEWHERE. 0.24 AT 75DEG F. AND ALL PURPOSE JACKETING, ASTM C921 UNLESS SPECIFIED 1 ,7 INSPECTION: A. MATERIAL: GALVANIZED SHEET STEEL COMPLYING WITH ASTM A 527, LOCKFORMING OTHERWI3E AND HAVE RATINGS OF 25 OR LESS FLAME SPREAD AND 50 OR LESS SMOKE QUALITY, WITH A3TM A 525, 090 ZINC COATING, MILL PHOSPHATIZED. SPIRAL LOCKSEAM 1 .8 MECHANICAL SUBMITTALS: DEVELOPMENT. A. EXAMINE AREAS AND CONDITIONS UNDER WHICH BOILERS ARE TO BE INSTALLED, AND CONSTRUCTION. INDIVIDUAL RUNOUTS TO DIFFUSER3 MAY BE LONOITUDINAL SEAM. B. PIPING INSULATION APPLICATION SUBSTRATE WHICH WILL SUPPORT BOILERS. DO NOT PROCEED WITH WORK UNTIL A. THE MANUFACTURER'S MATERIAL OR EQUIPMENT LISTED IN THE SCHEDULE OR UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED IN MANNER ACCEPTABLE TO B. ELBOWS: ONE PIECE CONSTRUCTION FOR 80 DEG. AND 45 DEG. ELBOWS 14' AND IDENTIFIED BY NAME ON THE DRAWINGS ARE THE TYPES TO BE PROVIDED FOR THE � , DOMESTIC COLD WATER PIPING: h' THICK. INSTALLER. SMALLER. PROVIDE MULTIPLE GORE CONSTRUCTION FOR LARGER DIAMETERS WITH ESTABLISHMENT OF SIZE, CAPACITY, GRADE AND QUALITY. IF ALTERNATES ARE USED IN STANDING SEAM CIRCUMFERENTWL JOINT, RADIUS TO CENTERLINE SHALL BE 1 .5 TIMES LIEU OF THE SCHEDULED NAMES, THE CO3T OF ANY CHANGES IN CONSTRUCTION p, HEATING WATER PIPING: 1-1/2' THICK, EXCEPT 54' THICK FOR 2' AND SMALLER � •8 FIELD QUALITY CANTROL: DUCT DIAMETER. SPOT WELDED AND BONDED CONSTRUCTION. REQUIRED BY THEIR USE SHALL BE BORNE BY CONTRACTOR. RUNOUTS TO INDIVIDUAL TERMINALS, LESS THAN 20' LONG. A. FLU3H AND CLEAN BOILER3 UPON COMPLETION OF INSTALLATION, IN ACCORDANCE WITH 1 .8 INSTALLATION OF METAL DUCTWORK: B. BEFORE STARTING WORK, PREPARE AND SUBMIT TO THE ARCHITECT/ENGINEER SHOP 3. STEAM PIPING: 2' THICK FOR PIPE SIZES UP TO AND INCLUDING 1-INCH; 2-112' THICK �+NUFACTURER'S START�UP INSTRUCTIONS. DRAWINGS AND DE3CRIPTIVE DATA FOR ALL MECHANICAL E�UIPMENT AND MATERIALS FOR PIPE SIZES 1-1/4 INCHES THROUGH 4 INCHES; AND 3-1/Y THICK FOR PIPE SIZES A. DUCT SEALING: REQUIRED FOR THE PROJECT. OVER 4' INCHES. B APpLCqgLEISE T ONS OF�ASME BOIDLER IAND PRESSURE VE SE�L CODE.CE WITH � SEAL ALL LOW PRE3SURE DUCTS TO SMACNA SEAL CLA3S 'B'. 1 .7 RECORD DOCUMENTS: 4. BOILER FEEDWATER AND BLOWDOWN PIPING 1-112° THICK. C. ARRANGE WITH NATIONAL BOARD OF BOILER AND PRESSURE VESSEL INSPECTORS FOR B. GENERAL: ASSEMBLE AND INSTALL DUCTWORK IN ACCORDANCE WITH RECOGNIZED A. CONTRACTOR SHALL KEEP A COMPLETE SET OF RED-LINED RECORD DOCUMENT PRINTS INSPECTION OF BOILER PIPING, OBSERYATION OF HYDROSTATIC TESTING, AND FOR INDUSTRY PRACTICES WHICH WILL ACHIEVE AIROTI6HT AND NOVSELE33 (NO yT �"' IN CUSTODY DURING ENTIRE PERIOD OF CONSTRUCTION AT THE CONSTRUCTION SITE. 5. STEAM CONDEN3ATE PIPING: 1 •1/2' THICK FOR PIPE SIZES UP TO AND INCLUDING 2 CERTIFICATION OF COMPLETED BOILER UNITS. OBJECTIONABLE NOISE) SYSTEMS, CAPABLE OF PERFORMING EACH INDICATED 3ERVICE. F I �S ` F I O O 1 ONE (1 ) SET OF RECORD DOCUMENTS SHALL BE PROVIDED TO THE ENGINEER INCH; 2' THICK FOR PIPE SIZE3 2-112 INCHES THROUGH 8 INCHES. INSTALL EACH RUN WITH MINIMUM NUMBER OF JOINTS. ALIGN DUCTWORK ACCURATELY INDICATING FINAL PROJECT CONDITIONS AFTER COMPLETION OF WORK. D. START�UP BOILERS, IN ACCORDANCE WITH MANUFACTURER'S 3TARTuUP AT CONNECTIONS, WITHIN 1/8' MISALIGNMENT TOLERANCE AND WITH INTERNAL C. PROVIDE ALUMINUM JACKET FOR PIPING EXPOSED TO WEATHER. INSTRUCTIONS, AND IN PRESENCE OF BOILER MANUFACTURER'S REPRESENTATIVE. 3URFACES SMOOTH. SUPPORT DUCTS RIGIDLY WITH SUITABLE TIES, BRACES, HANGERS N u c I e a r M e d i c i n e 1 .B OPERATION AND MAINTENANCE DATA: 72 DUCTWORK INSULATION TEST CONTROL6 AND DEMONSTRATE COMPLIANCE WITH REQUIREMENTS. ADJUST AND ANCHORS OF TYPE WHICH WILL HOLD DUCTS TRUE7TOCSHAPE AND TO PREVENT BURNER FOR MAXIMUM BURNING EFFICIENCY. REPLACE DAMAOED OR MALFUNCTIONING BUCKLING, POPPING OR COMPRESSING. /1 A. CONTRACTOR SHALL PREPARE TWO (2) SETS OF MAINTENANCE MANUALS AND SHALL q, FLEXIBLE FIBERGLASS DUCTWORK IN3ULATION: ASTM C 553, TVPE I, 3l4 LBS PER CU. FT. CONTROLS AND EQUIPMENT. S � �J � e m O a e I INSTRUCT OWNER ON OPERATION OF SVSTEMS MAINTENANCF MANUALS SHALL DENSITY, 'K' VALUE SHALL BE MAXIMUM 0.25 AT 75 DEGREES F. MEAN TEMPERATURE, 250 C. riE�D FABRiCATiON: COMPLETE FABRICATION OF WOkK A7 PROJECT AS NECESSARY TO INCLUDE ALL MECHANICAL WARRANTIES. DEGREED F TEMPERATURE LIMIT, VAPOR TRANSMISSION RATINO SHALL NOT EXCEED � �9 AD�USTING AND CLEANIN6: MATCH SHOPCFABRICATED WORKAND ACCOMMODATE INSTALLATION RE�UIREMENTS. B. THE TESTING AND BALANCING REPORT SHALL BE SUBMITTED AND RECEIVED BY THE 0.02 PERMS, FACING OF .7 MIL FOIL REINFORCED WITH GLASS MESH AND LAMINATED TO A. CLEAN AND FLUSH HYDRONIC P�PING SYSTEMS. REMOVE, CLEAN, AND REPLACE D. INSTALLATION: INSTALL METAL DUCTWORK IN ACCORDANCE WITH SMACNA HVAC DUCT ENGINEER AT LEAST FIFTEEN CALENDAR DAYS PRIOR TO THE CONTRACTOR'S RE�UEST 40 LB KRAFf. STRAINER SCREENS. APTER CLEANING AND FLUSHING HYDRONIC PIPING SYSTEM, BUT CONSTRUCTION STANDARD3 AND INDUSTRIAL CONSTRUCTION STANDARDS. FOR FINAL OBSERVATION TIME FRAME RE�UIREMENTS, AND SHALL BE INCLUDED IN THE END OF SECTION BEFORE BALANCING, REMOVE DISPOSABLE FINE MESH STRAINERS IN PUMP SUCTION O S M MANUAL. DIFFUSERS. E. TEMPORARY CLOSURE: AT ENDS OF DUCTS WHICH ARE NOT CONNECTED TO END OF SECTION B. MARK CALIBRATED NAME PLATES OF PUMP DISCHARGE VALVES AFfER HYDRONIC EQUIPMENT OR AIR DISTRIBUTION DEVICES AT TIME OF DUCTWORK INSTALLATION, SECTION 15440 7 PLUMBING FIXTURES SYSTEM BALANCING HAS BEEN COMPLETED, TO PERMANENTLY INDICATE FINAL PROVIDE TEMPORARY CLOSURE OF POLYETHYLENE FILM OR OTHER COVERING WHICH 181 W . M ea d ow D rive BALANCED POSITION. WILL PREVENT ENTRANCE OF DUST AND DEBRIS UNTIL TIME CONNECTIONS ARE TO BE SECTION 15060 - PIPE AND FITTINGS 1 .1 DESCRIPTION OF WORK: COMPLETED. Va I I C O I O ra � O A. EXTENT OF PLUMBING FIXTURES WORK REQUIRED BY THIS SECTION IS INDICATED ON C. CLEANING: CLEAN FACTORY�FINISHED SURFACES. REPAIRANY MARRED OR 1 .7 INSTALLATION OF DUCT TAKE-0FF FITTINGS: � 1 .1 GENERAL: DR4WINGS AND SCHEDULES AND BY RE�UIREMENTS OF THIS SECTION. SCRATCHED SURFACES WITH MANUFACTURER'S TOUCHOUP PAINT. H � � � � 1 .10 DEMONSTRATION: A. FULLY SEAL ALL JOINTS. A. DOMESTIC WATER ABOVE GRADE INSIDE SHALL BE HARD DRAWN COPPER TUBING, ASTM � •2 MANUFACNRERS: B. SHEET METAL SCREW REGULATOR ARM TO DUCT AFTER BALANCE IS COMPLETE. MARK 888, TYPE L, WITH 95/5 TIN/ANTIMONY SOLDERED JOINTS. A. MANUFACTURER SUBJECT TO COMPLIANCE WITH REOUIREMENTS, PROVIDE PRODUCTS A• SERVICES: AFTER TESTING AND INSPECTION IS COMPLETE, PROVIDE THE SERVICES OF AND DATE POSITION OF REGULATORARM. BY ONE OF THE FOLLOWING: AN AUTHORIZED FACTORY SERVICE REPRESENTATIVE TO PERFORM START-UP AND B. HFr4TING, COOLING AND DRAIN PIPINO SHALL BE BLACK STEEL PIPE, ASTM A53, OPERATION DEMONSTRATION SERVICE. C. INSULATION OVER REGULATOR ARM IS NOT REQUIRED. SCHEDULE 40 OR HARD DR4WN TEMPER COPPER TUBING, ASTM BBB, TYPE L. 1 . STAINLESS STEEL SINKS: B. START-UP: PERFORM SERVICES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN 1 .B INSTALLATION OF FLEXIBLE DUCTS: C. STEAM PIPING SHALL BE SCHEDULE 40 BLACK STEEL AND CONDEN3ATE PIPING 3HALL BE START-UP INSTRUCTIONS. TEST CONTROLS AND DEMONSTRATE COMPLIANCE WITH SCHEDULE 80 a. ELKAY MFG. CO. REQUIREMENTS. REPLACE DAMAGED OR MALFUNCTIONING CONTROLS AND EQUIPMENT. A. MAXIMUM LENGTH: FOR ANY DUCT RUN USING FLEXIBLE DUCTWORK, DO NOT EXCEED 5' b. MOEN; DIV. OF STANADYNE. G 0". 1 .2 PIPING INSTALLATION: C. MAINTENANCE AND OPERATION TRAINING: AS A PART OF THE MAINTENANCE AND 2. FAUCETS: OPERATING INSTRUCTIONS, REVIEW DATA IN OPERATINO AND MAINTENANCE MANUAL, B. INSTALLATION: INSTALL IN ACCORDANCE WITH SECTION III OF SMACNA'S, "HVAC DUCT A. INSTALL PIPES AND PIPE FITTINGS IN ACCORDANCE WITH RECOGNIZED INDUSTRY e. CHICAGO FAUCET C0. INCLUDING PREVENTATIVE MAINTENANCE SCHEDULE AND PROCEDURES, AND CONSTRUCTION STANDARDS, METAL AND FLEXIBLE•. M E C HAN I CAL PRACTICES WHICH WILL ACHIEVE PERMANENTLYOLEAK PROOF PIPING SYSTEMS, PROCEDURES FOR OBTAINING REPAIR PART9 AND TECHNICAL A3313TANCE. b. TBSBRASS SPECIFICATIONS CAPABLE OF PERFORMING EACH INDICATED SERVICE WITHOUT PIPINO FAILURE. INSTALL DEMONSTRATE ALL PHASES OF OPERATION INCLUDING START�UP AND 3HUT�DOWN. 1 .9 EQUIPMENT CONNECTIONS: EACH RUN WITH MVNIMUM JOINTS AND COUPLINGS, BUT WITH ADE�UATE AND � ,3 FIXTURES: ACCESSIBLE UNIONS FOR DISASSEMBLY AND MAINTENANCEIREPLACEMENT OF VALVES 1 . SCHEDULE TRAINING WITH ONMER, PROVIDE AT LEAST 7�DAY NOTICE TO A. GENERAL: CONNECT METAL DUCTWORK TO EQUIPMENT AS INDICATED, PROVIDE AND EQUIPMENT. A. SINKS ARCHITECT/ENGINEER. FLEXIBLE CONNECTION FOR EACH DUCTWORK CONNECTION TO EQUIPMENT MOUNTED 1 . USE FITTINGS FOR ALL CHANOES IN DIRECTION AND ALL BRANCH CONNECTIONS. ON VIBRATION ISOLATORS, ANDIOR EQUIPMENT CONTAINING ROTATING MACHINERY. 1 . S7 SINGLE COMPARTMENT END OF SECTION 15558 1 .10 ADJUSTING AND CLEANING: 2, INSTALL PIPING AT RI6HT ANGLES OR PARALLEL TO BUILDINO WALLS. DIAGONAL 18 GAUOE TPE 302 OR 304 STAINLESS STEEL 19' X 21 " O.D., COMPARTMENT SIZE 14• DATE 2 APRI L 2007 RUNS ARE NOT PERMITTED, UNLESS EXPRE3SLY INDICATED. X 18' X 7-1/2'; SELF-RIMMING LEDGE BACK, THOROUGHLY SOUND DEADENED, WITH A. CLEAN DUCTWORK INTERNALLY, UNIT BY UNIT AS IT IS INSTALLED, OF DUST AND DEBRIS. 3-HOLE PUNCHING FOR FAUCET. SECTION 75575 - BREECHINGS AND STACKS CLEAN EXTERNAL SURFACES OF FOREIGN SUBSTANCES. DRAWN BY MWJ 1 .3 PIPING TESTS: A. GENERAL: PROVIDE TEMPORARY EQUIPMENT FOR TESTING, INCLUDING PUMP AND �UST NO. SL-1921-A-GR OR E�UIVALENT BY APPROVED MANUFACTURER. � ,� GENERAL CHK'D BY WAT END OF SECTION 15891 GAGES. TEST PIPING 3YSTEM BEFORE INSULATION IS INSTALLED WHEREVER FEA3IBLE 81NK TRIM - SINGLE COMPARTMENT SINK FITTING, GOOSENECK SPOUT, WRIST BLADE A. PROVIDE UL LABELED BREECHING AND STACKS WITH REQUIRED ACCESSORIES OF SIZES AND REMOVE CONTROL DEVICES BEFORE TESTING. TEST EACH NATURAL SECTION OF HANDLES INDICATED ON DRAWINGS TO MAKE A COMPLETE OPERATINO SY3TEM. SHEE7 FILE P-SPEC EACH PIPING SYSTEM INDEPENDENTLY BUT DO NOT U3E PIPIN6 SVSTEM VALVES TO SECTION 15975 - CONTROLS 130LATE 3ECTION3 WHERE TEST PRE33URE EXCEEDS VALVE PRESSURE RATING. FILL ALL BRASS CONCEALED TYPE SUPPLY FAUCET WITH RENEWABLE SEATS, THREE COPYRIGFR 2005 6Y �AVIS PARINERSHIP P.C., ARCHIIECIS EACH SECTION WITH WATER AND PRESSURIZE FOR INDICATED PRESSURE AND TIME. PIECE COVER ESCUTCHEONS, 53/81NCH X 9-3/41NCH HIGH GOOSENECK SWINa � •2 AL� STEEL, POSITIVE PRESSURE, DOUBLE WALL VENTS 1 .7 GENERAL SPOUT WITH FLOW CONTROL-LAMINAR FLOW OUTLET, 41NCH WRIST BLADE HANDLES, SHEEf NUMBER: 8. TEST ALL PIPING SYSTEMS AS SPECIFIED. CORRECT LEAKS BY REMAKING JOINTS. 1/21NCH MALE THREAD INLETS ON 81NCH ON CENTER WITH COUPLING NUTS, CHROME A• DESCRIPTION: UL LABELED DOUBLE WALL METAL STACKS FOR USE WITH BUILDING A. PROVIDE CONTROL SYSTEMS CONSISTING OF THERMOSTATS, CONTROL VALVES, REMOVE EQUIPMENT NOT ABLE TO WITHSTAND TEST PROCEDURE DURING TEST. PLATED AND EXTERIOR FINISH. HEATING EOUIPMENT BURNING GAS, SOLD, OR LIQUID FUELS NOT EXCEEDING t000DE6 F DAMPERS, OPERATOR3, INDICATING DEVICE3, INTERFACE EQUIPMENT, AND OTHER M 1 ■ O � CONTINUOUS AND CAPABLE OF MAINTAINING AIRTIGHT INTEGRITY AT PRESSURES UP TO APPARATUS REQUIRED TO OPERATE MECHANICAL SY3TEM AND TO PERFORM 72' W.C. A3 DESCRIBED IN NFPA 211 AND UL 103. FUNCTIONS SPECIFIED. Cator, Ruma & Assoc. FILENAME: P: \VVMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\MECH\P-MLSS.DWG _ M1 .02 PLOT: OS/31 /2007 � 9: 15am REV: OS/31 /2007 CAD: MJohnson XREF: tb.dwg ' � ' • - � Archit ts i � i � m � 0 I \ __._'. '_ . 15 0 . I �. _. . � � � IIl,—, TI � � '�, II,� 30 I 0 0� ODHCO 2 8 0 � s �� L l.'� . I �o� � ^ M � 0� MI I 8 0 I R �'T}� I I II II 1 "__. .........._. ..— . ILy •� I ��I� x � 7� I "" - t 2/12 / , I � I 12 10 - f � 2301 BLAKE ST , STE. #100 ... . .. ... �I� 12/12 / ' . -- . . __ . .. .. . �� 460 �__. _ ____ 500 � �� 10/8 II ' 'I ZZS x DENVER, COLORAD080205 L_ __ T 12 10 ,- � 70 CFM , � � I CFM 303.861 .8555 F.303.861 .3027 DEMOLITION � -- L,J �I � \ __ _ e/� � �� I I � -- - 290_= �� \� ..._— Ir 12/20 � - 0225MAINSTREET UNITC101 GENERAL NOTES . — �- II �I 75iI � ONRH EDWARDS, COLORAD081632 ' � U 5 x 970.926.8960 F.970.926.8961 .�� � L D�3 io/io ' �� � q ' zzs �°M ` - 85 . I 1�--- � g g X 12 I CFM 7 . EXISi1NG ITEMS TO REMAIN ARE DEN0IED UGHiLY UNLESS OTHERWISE NOTED. ALL � I ' 8"0 � '" I 'i ITEMS SHOWN HATCHED OR CROSS HATCHED SHALL BE REMOVED UNLESS � I I g^p � 25p I- ' � � ' OiHERN1SE NOTED. y ' -'r ::. �� �y I ' X I � II I� 300 �, B�•m � � DHC_2 � �„ � � �, �, — � � CFM SERVICE W1h10UT FIRST COORDINAIING WITH THE OWNER. !- 100 i � X 35 i , 200 i 2 • CONIRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERNCE ANY SY5IEMS OR T I _ _ �- - - ', � ' -- -- .. . _ .--- _ ' 1 1, li �i 100 � ` j 3 . IT IS THE RESPONSIBILITY OF 1HE CONiRACTOR TO NSIT THE SITE AND CFM � � � 40 � CFM � / EXTRASTWILL EEALL WED �OR WORKM EQUIREDRTORACHIEVE THE END�REISULT AS /10 � ! I LL _ - I ; 8� �F� 2 140 _ - - - _ _ _J�� X 90 � , !I _ / INDICAiED BY iHE CONTRACT DOCUMENT. N � � 0 460 X _ II � � , . , i � B/8 I � , �E) 6 � \ 4 . CONTRACTOR SHALL DEiERMINE AND COORDINAiE THE EXACT E%iENT OF I ��L � f � I I „ ____ _ DEMOL1ilON TO FACILITAiE ALL WORK INDICATED BY THE CONif2ACT DOCUMENT. A 90 �� a ��A , � � � T 00 i� I ' a/8 10"0 UP �� �I ; — II - ` AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. � - - ' . , '„ ° � 14 14 ` 20/14 280 EA. TpREFR�� i �,�'_"� 5 . PRIOR TO COMMENCEMENT OF ANY DEMOLIiION WORK, VERIFY EXISTING CONDITIONS i ' 6 . ALL ITEMS IDENTiFIED TO BE REMOVED SHALL BE REMOVED IN iHEIR ENiIREN �i - - I DHC= � � �/ � / , UNLESS OiHERWISE NOTED. REMOVED ITEMS SHALL BE iURNED OVER TO 1}IE —� i DHC-8 ; ' 460 ; '-J I � OWNER UNLESS OTHERNISE NOiED AND STORED IN THE AREA DESIGNATED BY THE - L _ _ _ � � - - 20/10 UP �• �_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ y � —� �E �XHAU TO OWNER. REMOVE FROM SI7E AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER A fi•m � , � . . - - - - - - r � ' i� -- - � O ST FAN ON CHOOSES N6T TO ACCEPT. 90 � 1 ' � , , � / I, i ---.. . . .. / 14 . `_` �4/12 � 8-0 � ��� i .� � � . , , I \�J 8�8 �. � � � ,. R OF 2 10 . � i ���, / i � i , ('� . 7 • WHERE EXISTING PIPING, T.C. TUBING/WIRING ETC. ARE TO BE REMOVED FROM 90 .._ ' 140 � , - � CATC )R, R� I �'� .� (J ASSO ( .�I.'� T L'S, CC�. WALLS WHICH ARE REMAINING, iHE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL / , � - � �I CO'�SUI:II:� G NhCIIAKICAL'EL6C1'R1CAL EVGI�EERS CONDI110NS. � � � II 'I �' I AIR HANDLING UNIT / � AT CEILING. ADJUST 1550 Dover Street . Suite Two . Lakewootl, L'O 80215-3132 �_ ��� � z4 � z ' � �P � i� 16/8 UMIDIFIER �� RPM AS REQUIRED 30��232-62oo . Faz3o3l2333i01 � � -_ ._� � 8 . WHERE EXISi1NG PIPING TO BE REMOVED PASSES THROUGH FLOORS, THEY SHALL I � � e �' � / � � � / � ..... . . � .. FOR NEW CFM cr�4icalorrumx,eom . www r.r.to�rumn enn•. BE CUT BACK TO WIh11N CONCRETE AND FlLLED WIiH GROUT TO ACHIEVE A � ; " i SMOOTH AND EVEN FINISH WIiH CONCRElE SURFACE. i , v // ' ' ; � = = � � = = = i � I QUANTITIES. . .. ... � � � I I ^ � - - ° ' i _ lE"o0 : . / ' �y ..,.,. �� �i� '.......----- ' � ' , 5P , , , I ISSUE/REVISION DATE N0. ' ; " is io 2 10 I � � � � � � HEAi1NG COILS 20/20 RELIEF DUCT J TOV CODE REVIEW 6-01 -07 Q1 90 _ � ' 30 14 ; � �1^ � HUMIDIFIER I i UP THRU ROOF / _ _ � / 8 �. .2Da�, i . i � � i 22/10 ' � � � ' � 22/10 � ��, i i i 22/12 0 ', I� '�, g^o '.. .. ..�i . — " ' i - -.... , - - - � --. ......_� c� � �q� � -- _..- .. ..... .... . .. - `-� ��� � ' ��� � � 20/20 RELIEF DUCT ° I ..s.--_ _... _ � N . ..... .._..—_— '� UP THRU ROOF TO ROOF 50/20 � I HOOD I, j O.A. DAMPER / � � ---._... . . . ..--- �' �i �--- _ �� I� I � PARTIAL FIRST FLOOR HVAC DEMOLITION PLAN p SCALE: 1 /8"=1 '-0'� 11 y 3 1. t�1� � � ��y� � � �{�-- M 100 M I 250 x _..� II I� ,._. .. .. . . .. . .. . --- xg"�����/ 13� I�I,' _..--- ....-----� \\ / o o 'I i� I �'� II �DHC-2� 1 770 4. �__ . -- � i2/i2 i � _' ', iz/iz I � soo z� _ ^ i2 io . no - -�0�8 — , �, ,, , 46� �__ _ I 225 x Vail T - . --- 12 10 . 7 M —... .._ .. .._ _ ; 70 CFM II -.\ I . . CFM �' -- 7 8/�= -. .... '�-- I , � r � � T , �o —_ _ � __ _ . , 2,zo P - Valley � ` \ �4 J� TO AHU 5 �A 6"0 I __ )LH�� HC 5 10/10 �I �� ON RO I 225 CFM \ i I • , v °�' I ��I - �� 8 8l X ' 12 �.g/ � � II CFM ',. ,I �� 8„0 z5o � , —� � � 3oo �� � Med � cal �J�� � 1 - _ � �' ' T � "`� �y H _ � X .^ ' CFM �� . 8"� � i 8 _ _._.� I � T X 200 I, ' , I _ _ .._ . . . _.. _ _ ._�' I� . T , � � am Center _... ' , 00 I � X , 00 _ . _ � � I �, .... ' s M _ ._ .. ....._ � � %_ � CFM ', % — �� � 35 CFM ' . ' . 140 �n � C45 - 1 �6•' � . i I � Aar n. �' _. p� � t/ � _, . N �...^ 8 0 FM /.14 . 140 I X 90 \� \ �.. 460 X _ .. . . _ _ , ' , � 8/8 � I (E) g 0 \ \` J A '� � � � _ --'. � .� — � —t� _ .. � , .— .- - �--- _.. . _ . . . . --- ` '-- � 6/1 " � 10/8 . .... .. _ � A 9�. a �\ � � T 00 � p��� 10"0 UP � c.-- ' /� �. -- �.. .. . ^ o C THRU RO � .- I '� 4 14 �- 20/14 280 EA. TO EF j �� ... KEY NOTES : � � - ° ° ° oH�a 460 - ��= --� __ � ' 6�0 ' 8'� B - 2 10 DN. F- 10/10 ' I 12 12� T0 O1 PROVIDE BAS CONNECTION TO AHU TO MONITOR STAIUS OF SUPPLY FAN. ��--e. _ - - - , - I E��XHAUST FAN ON O � � c' y� � � i i � A '-�p�1 � '�2500 . a� I� \�' � . � � . . �i ROOF F i rst F I oo r 2 LOCATE LOUVER IN AREA OF WALL NOT COVERED BY FACE BRICK. � � , ' 7 � 24 � z � 310 A 8 � T r , g/g ' Ili � � J I , i � �% � 24/14 _ � 7b ' -�� � � � � AIR HANDLING UNIT Nuclear Medicine A�6"0 , ,� . � ���.`. `, ` 24�� UP �, � I : -6`8�.�,` , '� �I ` 0 \ � ; ' I, j AT CEILING. AOJUST i g 0 !r � � I � I RPM AS REQUIRED - ' �:.� ' FOR NEW CFM SPC Remodel � L� 10 10 � I 10 0 � A �! QUANTITIES. I� �I ;�'�i , "r-- � � � I 14 10 I III �?R.,,,^` 250 225 � �v �' ----� `- -- o '�- - - . � � '• i I � � - 24/1 � ' ,._ 16 10 I p��, ��, ff '��'� i � I m - - - - "- __ '� � � HEATING COILS 20/20 RELIEF DUCT 7� '�� i , __"-' ' ' '-""""- _ ...— 30 14 ' 0 _ .. _. . I - ° UP THRU ROOf � � 0 ' - - - � - - , _,- . _ :_ _ . zz�, o � � l� I o - 181 W . Meadow Drive B(�2-10,�,, L / Y2/10 C 8 / C i i 22/� 2 I �._. .. \ / � v 0 12 2 10 0 i 20/20 RELIEF DUCT ,� � �/ a � l , Colorado ,�-� '�, �I �bp �� \ '� UP THRU ROOF TO ROOF 50/20 I �� � � � � � , ;j ', 8 � �O c,�. � : , �,�. � , > � ,, �, H000 � � �i 1657 ..\ O.A. DAMPER % ' �,I - ••.... ? � ---� . ��., . ' _ --_._—_ --__—_- G . �.;�P �'`�-�— �� ., �. ;; `�-C Ccm� G� Tt�"' i G� PARTIAL FIRST FLOOR HVAC PLAN ;f= ��� '�� � SCALE: 1 /8"= 1 '- 0" PARTIAL FIRST FLOOR HVAC PLANS DATE 2 APRIL 2007 DRAWN BY MwJ CHK'D BY WAT SHEET FILE P— HV1 COPYRICHT 200.5 BY DANS PARINERSHIP P.C., ARCNITECIS SHEET NUMBER: M3 . 01 KEY PLAN Cator, Ruma & Assoa FILENAME: P: \WMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\MECH\P-HVI .DWG _ M3. 01 PLOT: OS/31 /2007 � 9: 15am REV: OS/30/2007 CAD: MJohnson XREF: tb.dwg bgl .dwg hvt .dwg tb-a.dwg ' � ' • - � Archit ts 2301 BLAKE ST., STE. #100 DENVER, COLORADO 80205 303.861 .8555 F.303.861 .3027 0225 MAIN STREET . UNIT C101 EDWARDS, COLORADO 81632 970.926.8960 F.970.926.8961 PROVIDE END OF MAIN DRIP T PRIOR TO LAST TAKE-OFF I N a 1 3f4` I 3/4' � 7 y C,�TOR, �lI ,ti1A �i .� SSOCIATES, �.C.). T�— COVSULTi�G MIiC11,1NICAUGLPCTRICAL PNGI1IEItti 1550 Dover Street . Suite Two . Lakewootl, CO BU215-3132 303'232-6200 . Fax 303,�2333707 LEONARD 3800-EVBD IN A $TAINLESS cre�cato•ruma,com . www.catorruma r,om n STEEL CABINET NATH VACUUM BREAKER AND IX17LET DIAL THERMOMETER. ISSUE/REVISION DATE N0. STEAM GUN AND HOSE, LEONARD N-2-SS AND HDH-2o. TOV CODE REVIEW 6-Ot -07 � i� l I� ' I I �I ��, Ii � � II I . _ . � � , _.. _ , � � �i ' ' � ; __. _ � 48" �p , � FINISHED FLOOR b � II�—� I I ' ! � __ �. . _ _ ---.. _ � �_ _ _ _.._ Y --. � I ' � ',I '' � -- .. .._..._ _. _ . I i --- — . .. .. _.._. 1 ' coN�o� –._ . _.-I _ . I _ti STEAM GUN PIPING DETAIL ' ' � '�'� '- ---J . . - ---- - I --- I � ? II SCALE: NONE � ' ---- _ _ --- WATE�HEATER �� � �_..-, , .--- � VALVE _ BOILER �II I III� . , �/ ' II I ' I' �l 3)^ ' HWS � � ...RI �ORfBUST10N AIR DUCT ... . ...._- .,. .--- I ��. ' I� � , , v 2yz� �N \ ��. � - , (2j3 HS DN. THRU FLR. � I` , — � 2'MPS UP � H� / i T.C. COM�RESSORS �� L 2; - - - - -��L� 'Cf�I .. .. . 2� 3„ .J T C� PANEL._ _ _ . . , _.__ � I -- -- - - •� � � - - _ � � a � �� � �Y,�� _ � � n- P ER ESS p_g P-7 , �., �� , H.V NI � y2" � . , _ - i , �'I N0. 5 � i ►IIllM1 ' �� �I H� P-8 AHU-6 '. , . x - ,. � ' , ,, -.... ' � i — — fHyy� '� � �� HEAT EXCHANGER � ----- _ � �, �. 7 � '�, -- — �� . .. .. _... -� .. _._. �.` ' .. �, � �, . ._....... .. . r— . . .......... _...j. __ .... . --- _ _ —: , . � v 4'. _. _ _ _ _. --�� 3 _...__ I 1 Vi" - � �. �I........ ......_._..._—� '-'--� CAP FOR � —. _.._.. ,.. �� \ �FUTURET v�x � % \ _ � ' � ...._— .._� nn— ----. ._ ... . . .. .--- . . . ... .. ......_� _ _ . -� , Va i yl _ , � _. . _ _ . _.. __i � � � � �� - , � � , v � , . .. . _.- . � � � _ .._� 1 -__ __ ! ' � s , - __ ___ , ' I � i � , , v.° I I! � ' _ ��, � �----- � � ; . -- -- � _ �_ Valley __ —' i ' I'' i ', ' -- -T '' \`� 'I Y ,'i • KEY NOTES . � _ _ ----- ' � > � � � � _ � � � __ �__! '�� MeC� 1Cal O1 2"MPS UP TO MECHANICAL ROOM ON SECOND FLOOR, SEE SHEET M5.02 FOR , � J , I � II � �� CONi1NUAitON. COORDINATE ROUTING W17H OWNER. i� ! ! � I ! � � - a= � � � �� � O2 3/4 MPS DOWN IN WALL TO SiEAM GUN CONiROL STATION, SEE DETAIL ON `-- - = � , }�� ,, � � \ ' , J iHIS SHEET. � j% � � '— , I ; y \_ � �3 `' �. __ . __ ---- O PRV STATION, PROVIDE A SPIRAX 1' 25P PRESSURE REDUCING VALVE SIZED - ' , � � � L �� I i FOR 1000 LBS/HR AND A PRESSURE DROP fROM 90 TO 70 PSI.. F _ — ' �1 iV4 � - _-,.� � _ . __ c � � . - ----- - _ . . _ � �� � �- _ �', . _.._. ...._... . _ cna wn,-` � . . ',, , � \ . 5,' i 2 '-�k-.. ..._—_— , i . , !\. '. '' _ , . _ . \ _ ,_ ��� '�..__ ' ' �•\ / _. I � r . . -- . . . ._.... � ' '� . — �— _ II . .. _.__ . , , � . ' � . � J_._ . . . . , 1 , � �, _'_ ' . . . . ,l. ' " ' _ '��� \ " . � —_-- _.., ....._.� \" . .-.-_ , � y�'� ,� 111 � _ � �. — _ ' .. ' , . ..�\, , � � , . , I , . �� . . � `� . - -- - ; - ' 2' �_ - � __. _ — ' -- 3 - First Floor �— — N �� '. '�. —�— '� _ �� � . . .. _ _. Pai� Q q.,,� , n _ / '. �N _=�... . 1.�-, � s a � _J \ •• ` � � _ P �Ir-'- ' Cl. — �' � � ,� � � � � � - - _� Nuclear Medicine _ � Li ', � �_, . �, , , � � � � � , � , _........ \ I.. ,i '�CMEJ ' . �' �, I i �,I �� - ��� �, . �--- �-- -- � ;; �° - � � , � SPC Remodel � > > /4� VALVED AND CAPPED I �� I I I � � FOR FU7URE I I I i i i � � � � 7,.,�`--� I j�ll I i �� ' I — ^. �II Ll 3 I sreRi��4� I CONDE '� i . . . . . .�—�j ` I _ I �— ` p ' T � ` J � NSATE COOLER i 0 I � , - -- _ � ` ; I �_ r � --- ``_ — T - - ', o ! 181 W . Meadow Drive I '�jz � ' r — 4- - - Ii�� I �� l ;=, _ � _ _ = r� , , . , , ,, Vail , Colorado _ , � _ _ _ � �= _ _ . . _._ � � ' 4" _ -- — -.... .. . � i 3✓ - l'., � � I , , -- 81657 _ � , .^ ,, _ - - - - " - --- , , J - - - - ----- - � -- . _ , � � - . - - �.:. s _ , U _ .__ = I I�� J � � I �� I ' 'i I i ,_-J � PARTIAL FIRST FLOOR HVAC PIPING PLAN p SCALE: 1 /8' =1 '-0" PARTIAL FIRST FLOOR HVAC PIPING PLAN DATE 2 APRIL 2007 DRAWN BY CHK'D BY WAT SHEEf FILE P-HP1 CAPYRICHf 2005 9Y OAVIS PAR'INERSHIP P.C.. ARCHRECIS SHEET NUMBER� M4 . 01 KEY PLAN Cator, Ruma & Assoc. FILENAME: P: \VVMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\MECH\P-HPt .DWG _ M4.01 PLOT: 05/31 /2007 � 9: 14am REV: 05/30/2007 CAD: MJohnson XREF: tb.dwg bgl .dwg hvl .dwg hpl .dwg � 6 � � � � � -- �-� — — _ �� '��_ — -{� — —,�I I — . ._ �--' �� � ���� co� R � o� , � � , � � � �, �� Z�,W �P �3• ' • - � Archit ts �-- - -- �--,_ �� _ . � - � � i ?� ��,' - �� :_ � ...BD ��� ,—� I MECF- . i I I 4,� i _. t� CCN � I, TER � �, � I � I - - '� - � i � �I I I . � 2301 BLAKE ST. , STE. #100 1 ' � DENVER, COLORADO 80205 � I r . ._ �_` _� - — — -- 3" r\ � 303 861 8555 F.303.861 .3027 � - �_ -�-�� q^W�p I � - - - - L �I `� , 0225 MAIN STREET . UNIT C101 EDWARDS, COLORADO 81632 _ - - _ - - - �--r =� , 2 �� � I � �� 4" 970.926.8960 F.970.926.8961 _- � �L, I �, I � � - BD - I I II I i � �" w. u I � � _ ,. � �. , , a� � �/'' co � �(�2� � n �n � � �, I � _ � � 'r ' IC � d � ^� I I , ' , �I L -I 2"W U P / TS �T� `�"�. , I I I I - / VENT i�B�VE CLG. i 4_ _ . . - �I�,, _ /� � .�.. z � �i2 II � — � � r— � , �iB - - - - � � t � E � � DEMOLITION � 3. � 3�F�o � � �� 1 Ys"VENT �fELOW �I �i4_ ... - . , _ � FLOOR �,� I � I , � �� �� ! f� � � I \ n � 1 GENERAL NOTES . — --��_ ; �J� , I �';� � �� _ �I � r - - �1 � � - -� . � ' ...� ��. �, ...� . � 1 . EXISi1NG ITEMS TO REMAIN ARE DENOTED L1GHILY UNLESS OTHERWISE NOiED. ALL - - � �-- 3� • � � _ _ � . — — ,� OTHERWISE NOlED. J - -_—, r- , , � � � �3�� �'� � 3 ITEMS SHOWN HATCHED OR CROSS HATCHED SHALL BE REMOVED UNLESS _ I , � - ' 3�� — BD� 2 • CONTRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSIEMS OR I � -`� -- ,�� 'i l , ' � I I � 2" . UP Bp � _ � SERVICE WITHOUT FIRST COORDINATING N1TH THE OWNER. ' , ; ; F=^ , __' . � - '� _ _ L _ _ _ 1?I _ _ _ � � _ _ ' _ _ _ _ _ _ _ _ _ ' _ _ _ _ _ .� �- ..- __..... __ - _ _ .�. _ �'�. I 3 . IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE AND � �I , � � II ,� � , o � i ' r � ; ,� i ' _ I �/�'�' Jrl --� I � : l I I I ' I --.. -- � ' I I _ � .�� I i �� A m IS al R - - - - - - - - - - - - - - - - - - - ; ' � ' I/ � ' � UNDERSTAND h1E EXTENT OF THE REMODEL WORK RE�UIRED PRIOR 70 BID. NO - / EXTRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE iHE END RESULT AS � � ,�/ i, • INDICAiED BY THE CONTRACT DOCUMENT. � f ' � . � ^ti � k' � / - CATOR, I�� I � � A � ASSC�CIAT�S, CC). I � ' . rd � � I � , � '� � I ��. � � CUNSi1LTiK(� MLCH,IKIC.IL 'CLf('TRiCAL LNUI\CCRS 4 • CONTRACTOR SHALL DETERMINE AND COORDINAiE THE EXACT EXTENT OF ' I � ' I " j ' � � 1550 Dove eel3Su W0 � 3032333 00 80215�3132 r Str ite T -. ... _ I I • , ' I . .. -��.� �- 30:il2' 2-6200 . Fax ' ' DEMOL1T10N TO FACILJTATE ALL WORK INDICA7ED BY THE CONTRACT DOCUMENT. .- - _ _ i i i i tr 3" W. .UP cre(�cato•ruma.wm . www.oarorruma,com 5 . PRIOR TO COMMENCEMENT OF ANY DEMOLITON WORK, VERIFY EXISTING CONDI110NS u ' - � , � , , � 2• ' � � Z,TQ _ � � i « AND NO11FY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. } ` � r - - � � I- ��y - - --�- ii�� "" I FLOOR $�NK � --.. .. 6 . ALL IiEMS IDENi1FIED TO BE REMOVED SHALL BE REMOVED IN 1HEIR ENTIRETY ! I I I ' Z� � ISSUE/REVISION DATE NO. UNLESS Ol}IERWISE NOTED. REMOVED 17EMS SHALL BE nRNED OVER TO THE � ' I �� 2• H OWNER UNLESS OTHERWISE NOTED AND STORED IN iHE AREA DESIGNATED BY 1HE � " OWNER. REMOVE FROM SIiE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER � I I I � � � I I ( ' ; ' � L' _ ' � � ^ � � TOV CODE REVIEW 6-01 -07 CHOOSES NOT TO ACCEPT. - - - : ,� I . � L - - - _.� 'I ' I " I r� � ' 7 • WHERE EXIS7ING PIPING, T.C. NBING/WIRING ETC. ARE TO BE REMOVED FROM - - �. - 1 �� , � _ _ _ _ _ _ � � � ' ; , � WALLS WHICH ARE REMAINING, THE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL -' - �- ���} - - - � �� � � � "� � � - - CONDIi10NS. " � 8 . WHERE EKISTING PIPING TO BE REMOVED PASSES iHROUGH FLOORS, THEY SHALL � I I BE CUT BACK TO WITHIN CONCRElE AND FlLLED WITH GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH Wlhi CONCRETE SURFACE. � I I I — , � � . ... - ��.. , I I � - - - , .. - - - -- - - � . _� �... � . ii _ I - I � � , � I � + --fi� I�. ... --� - - M � �— - , I ^ ._ I._ 1 �i — \ � �i � �'g6 � `� I � 2C � II � �'-- -� �-: ,_ � j �J �I �''I I — �i,r+T�.. .._J II I� I � �� I d'� I II I �z� G� PARTIAL FIRST FLOOR PLUMBING DEMOLITION PLAN — SANITARY WASTE � SCALE: 1 8 =1 '-0" C'. 13g p1 Z: :.S � ';i � 'W� �Y 3 ��• ✓ ���� fl%NIdIt� � i i i I I --+- .... .. _ .. -- _.. � .... . .._ �.... ... � 1 - - I. ....- . � --� _. .-- — ,' — . .._ ��_ . ._.—. I`_ .._ — ...._ _ � — � . S�- . _ .. _: ._�-- �' � � _ � _—��� �.... Ji -- / � �— � � �I , co��� I \_- � T ' _ � �- J � 3 Va�l . � -. \ �� 2.�W �P � . � i I_ I. — -- � - .._ �. t � , _.... .. _ ........ _. .. _ . —���_� _ _ - - - - _ _ _ V 11 � � , -_ ,,� � � - � -- __ a ey , , , r ,., BD 4�� '' I _ . ... ._. _... � � �� — - � ... .. .. �� �' � � . . � .. . �. . ... . .. . .- ___ ' . __ � '� � ' ' - - — � _ _ Medical � . : , I � � � � J � '„ � �� � 'I � J,� �R . I� . i \ i .9�i _.. .. `� �. ...._ ' . - - - l � � ..� �° - enter i � - � _ _ � - - - - _ _ � _ , _� � - - _ _ � ,� �. - - - -a� - - — , � � D � � _�,� . . _ ._... _ _� U— '�, 4 W UP ' .�I 2�1. � —.-- ._ . .._ . . _ .. - . . __ . .- -- � � — - � � � �I �� . � . � . . 4" i . �. . �,� .. .. .._. . — � -- � . . ,i � _ , . _ .. . .. ..._ . � . � — � _ � — — BD �� i , � , .� _� I � : ��� o' W. U�.�. - ' . ,,.. � —.. . . � . � -- � �� — y^W �p y � -- , j` CONTSC�(2) 1Yz" ' ., � ! i,� . �._ �_., �_ ,�, TO •4.Yi' , �. � _ � �I3 UP X p, �� 2 � __ � �AB LG �, /� _ r ' � _. ..— _ � - _ _ � � ' -- j- - — I�, � � e � - �._ _ ��p _ � �/ � i � � �3 � "'T� � I ,�� _-- II ��- w/, y 3'W �.. FLOOR ELOW � � � �\ - - � � 3" k 1 Y2"VE : , -_ I -_.. - . . ,�. . ., �•. � — � � � _ �� � � First Floor _. �-- ' ' , , /z•v u�� � _ ' _ - J- � , I `� . . - ,I - � __i - �- �- '� . � � - „ \, , ,� . -- � ' - i - . � ... � .-��- �3 �.__J ' „ - - - �� � � Nuclear Medicine _ � � � f I ' � � � 3 � — — � _ �. � �, ._ � ' _ ���u � ;� , s�:_ ti ;A� ,.. _ eo � SPC Remodel I ��— � � I �. i�T UP/ �— BD � �� I � �-2 I -' .. I ' � ' �._.:- o" o _ I i \ ' �� i �i ' �I' �I / _ =_ - / � _ i - -- _ il� � m c C � � � : - - - � / �_ I--. � � �- j ' �, � � � I - `� C , �� _,� —._ --- ,-. . . . . �� i,_,� .... ,. . I i _.,�, - . /C_' ,. �', i, i I �-n. I I ... - _ ' I�. _ ' ..._\J�I ' -_ I� _... .. .._ ` '. . ... �.� --� �-- ,� , ' ; � _ .. ' _. _ — , _�'� 181 W . Meadow Drive _ � ��I , , � � ' - r F. � ; ' . .. • :7� ....__ �-_ - � � „�_ . � _ ,_ �, �' ,J � 2•W 3� W. �P � , I Vail Colorado - � ,, _ � _ ' • , ' -�, � , � , . � .. -. � s-:z ri 1 1 /2 V UP I � OC- , � � i i � - - � -• — — — —_ _ 81657 _ � , , _ 2. `� y � � .� r2 9�- - 2, � - �� �. �� 2" -�J s.- p , �i� � ,g_1 , _ .�� " - _ . �� I _ _ . _ I �` L� � ,`� ._.� - ,k �I. .. - -- ,. ; - _ �'i I �� _- -- �-�� I . TO FSP1 �i I � I --�- - _ _ -- _ � , ; ,., .,, , � \\/ �,,., .- . "- ' -.. ..." '� ... . ....�,.� .- .... _ . .. . _. ..... ._ � � _ .. .. .-----..... . � li �� i i � �,j' . �, �I — /,. 'r� �'. i^\ '�, �� i ���, . . ._. .... . . ! � I r-'�-- - - � _ PARTIAL FIRST FLOOR -, ' �-� =. ' ' �- . . _ _ i (� _� ,-;� PLUMBING PLANS � � . � - , -- - . �� � ;`— : — - ,�,; � �� ` , I , , � _ _ _. _ _ . ... � �5e i � � 'f � � _ .- . � SANITARY PIPING _ "� I i i.; - � [ � a il - � ',, �` �I I, � , � �-\ >'\ I � , / „ � ,r , �li r '- I `�,o/ �''' . . � IIpI�. �, — . --:.. . DA' � 2 APRIL 2007 �'� — ' f- _�. /,I ~ � I��I', ' ' � z � DRAWN BY Mwd � PARTIAL FIRST FLOOR PLUMBING PLAN — SANITARY WASTE CHK'D BY WAT 0.7 SCALE: 1 8 '=1 '-0" SHEET FILE P—PPB CAPIRICFrt ZW6 BY DAVIS PARIWERSHIP P.C., ARCHrtECIS SHEET NUMBER: . M5 . 00 Cator, Ruma & Assoc. FILENAME: P: \VVMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\PLBG\P-PPB.DWG _ M5.00 PLOT: OS/31 /2007 � 9: 14am REV: 05/30/2007 CAD: MJohnson XREF: bgl .dwg tb.dwg ppb.dwg � � I I a '� 02 ' I � � I I � v / / �� I�--- _ — J — � I — — � � i , �„ 02 - - - - - - - - - - - - - - - - - - - - - 02 '�� I ' � ��� � �- - - - - - -- - �. - - - � . � - � Archit ts i ^ t- - iv�^ - - - -:.-7 2- VAC � VAC � . �2^ � 1 �,, 1Vz" - --�jj 7� .�I i'i° 1Y4" � � I 1Y� ,I _ .. ' I I ^ , �^ li _ 1 . II I �J r- I�"� �i u Ii � 1Y4" �� N� ECH . p � '�� I " � n iL" � � �— I O � I �� I� I �I � — T cv . . � I � . � � IEi I o ♦ 4"WC �2 ^ y� i i � � 2301 BLAKE ST. , STE. #100 � � -� L ' � VAC , VAC 3� I I DENVER, COLORAD080205 � � �' ii - ��`, �, 02 1 ' � I I 303.861 .8555F .303.861 .3027 � — --- — � �i _L� '�'�,4 —._ —. . — — �`� Lu�- -� � � 0225 MAIN STREET . UNIT C101 _- _ � - � � _ _ �� o SA-� -' Z i CONNECT 2 � VENT EDWARDS, COLORADO 81632 -- � ^ � ff11 �m � LOOR i I 970.926.8960 F.970.926.8961 � � i - � � i � � ��, � � _ � � i i i � i � TO VENi RI�ER 2- ---- - - � � - - - -- u� � � �i � ZVB � I � � � �i � 1 "CW AND lh"HW� N I � - -� ' � I � I � li TO WC-1 AND L 1� �� U �t �= ° ' 'I 2" W DN. 1Yz� $ C � � 2� 2 i � i I I 4o W EBELOW. E � I � , Nt" L_ _ �`^ � r 4. - - -- - -OZ - - - - - � -r � I I � ) I Sh" i i � � - - � - j � ` 1Yz" �, � i Vz I I � � � VAC }1 I N EWORK � 02 � �n 1 -z - ^� I I � . I i� T � , o - i'i DEMOLITION j � � � � T� 02 ^ i ' TE LOW vAC � _� ' � i . +h" i Ir--, J �� �, 2'Y'DN T • � ._ � -� I , � pI I � - - � - , � ,� � �i � GENERAL NO ES . _ _ . � . � --� �� � _ � --�--u - �— � � i � r= - - - - - - .- � I `� � � � ' REMOVE AAP REPLACE 1Y�" VENT 1 . OXTH RWISE NOiED. REMAIN ARE DENOTED LIGHTLY UNLESS OTHERWISE NOTED. ALL -_ o �- i � J I r¢ I !�� - - , I r� ` , � Tr - - -MA - -02 ; Y 02 - �4�A -- - -- - - - - -- - --- - ?~'�J W/ eW 2 I I I I ITEMS SHOWN HATCHED OR CROSS HATCHED SHALL BE REMOVED UNLESS j �I -ri �_ °O� �} -� � VA � VAC � 2° VENT UP , I 2 • CONTRACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS OR - � � � � I 1^r'2" S%a� � I T 1 " Yz" � � SERVICE WITHOUT FIRST COORDINAT1NG N1TH 1HE OWNER. � �`� � � � � � � Z ZVg - - � _� _ I - MA - T I - - - - - - - - - - - i r 3 . IT IS THE RESPONSIBILIlY OF THE CON7RACTOR TO VISIT THE SITE AND ' — - , � - - - - - - - - - - - - ' I I r -�� -- yq � � . � �i �� „ , , � , � � , I � , � � ' V � UNDERSTAND T}iE EX1ENT OF THE REMODEL WORK REQUIRED PRIOR TO BID. NO - 02 —�- � , . ' � � ' � � I � ` EX1RA5 WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS � _�-, L yg^ �_� - �� � �j y�• ; ti ' . � �.�; ; �• �' � I � � I � � � � � ��� �i�TOR, RU .��IA � ASSOCIAT�S, CO. INDICATED BY THE CONTRACT DOCUMENT. , O� � �y^ o � I i o � i ' I �4 ' - J � � � � � - � �� i � I_ _ - = J I I CONSULTInG MCCH,1\ICAUGLPCTRICAL eNGINPCRS 4 • CONiFiACTOR SHALL DE7ERMINE AND COORDINATE iHE EXACT EXIENT OF _ _ __ _ _ _ I ii W�_� I!- � ZVB �I Ii I � ' �� � i ' � � ' �� �� � � v� I � 550DoverStreet � Suite7wo . Lakewood, CO 80215-3t32 DEMOLITION TO FAGLI7AiE ALL WORK INDICAiED BY THE CONiRACT DOCUMENT. ��- i �� � � � , � � I _ Z �..� LI 303,�232-fi200 � Fax 30J233-3701 � . I I � � • ' � �4 � � a ��� �� � �� � CfBQWt0�fu0td.UJf11 � W'MN.CZIOffUmB.000t I 5 . PRIOR TO COMMENCEMENT OF ANY DEMOLIt10N WORK, VERIFY EXISnNG CONDITIONS SHr1 4" W DN. �� ' ` ,I � _ _ - ' � i I � � i � - - - � ' 3" W. DN. AND AND N011FY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. � - I i CO�INECT Tq (E � � � � , li � -- � � 4" W BELOW:`� � - �; FS ' ; � 2" VENT UP 6 . ALL ITEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN 1HEIR ENTIRETY I � I - - " , � I � ' � � � � ISSUE/REVISION DATE NO. p ' � � PROVIDE SHOCK ABSORBER UNLESS OIHERWISE NOlED, REMOVED IiEMS SHALL BE TURNED OVER TO THE _ , 2 1I�° � i i I � , H � • ON CW PIPING SERVING WC ' OWNER UNLESS OTHERWISE NOTED ANO STORED IN THE AREA DESIGNA7ED BY iHE �- - - - �- -r - - - - I� ;��i -I---- -� , , I � � OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER � i , � � � � I TOV CODE REVIEW 6-01 -07 CHOOSES NOT TO ACCEPT. - - I " , � � � � L + - i- - - � �� � � I �� � , 7 . WHERE EXISTING PIPING, T.C. TUBING/W1RING ETC. ARE TO BE REMOVED FROM � ' ' � � N �__.__,_ . .� �, � � � � - - - - - - � ` - - -i ' : . � . - . - . . -.. _ ' � " , ... .. �-. .--�—'- WALLS WHICH ARE REMAINING, iHE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL -0 �n 'I I � Zn W IDN 5-1--- I _ _ _ _ _ _ _ _ _ _ CONDITIONS. � 8 . WHERE EXISTING PIPING TO BE REMOVED PASSES ikROUGH Fl.00RS, h1EY SHALL � '- � BE CUT BACK TO WIIHIN CONCREIE AND FlLLED WITH GROUT TO ACHIEVE A ' i CONN CT TO (E) I r SMOOTH AND EVEN FINISH WIiH CONCRETE SURFACE. I I i i i �, 4" W �BELOW. I �I, - � � �� � � � � �� � '�' � � I � _ ��.._e _ _ � 8 �. ` r— . — — I —� I S ' �'�_ � , �� �� �I I �- � , ',; . I � TANKULK OXYGEN � � -- , � � 19J8 9JH . � I � _ �-�-I_ � � ' ry � � I ��� �' I 'F I I �I�I �-�II '.�� I ��� I G� PARTIAL FIRST FLOOR PLUMBING DEMOLITION PLAN � SCALE: 1 /8"=1 '-0" 1f V �_ f � � � Z% � • � � � �.��--- — ' � —�� I � ' _ ��" 0z _ - �� I ��. � I� ���—�'—. ' �I I'�— � �I� I I— --- �— — , , oz oz coqRi � a , , �� z- - - - - - - - - - - - - - - - - - - - - - - - - - - - - --� '�" � �--- — • �--� � _� � �� �- _ , v.. 1 - - - Va � l - __�>>] t- vnc' ^ , u �.0 iv,^ � i �� � • �ZL � iv4^ t +n" _— .. -- -� -_ n ._u _ . _— -. ..—. .— �.. _ __ ; �n . _r �, Valley — �- �� � � , » ; , v. ' ' --� � I �--.._ � � � � � I • ' �� . V� E C, F . � � n � '. �'i" ' ' �' � 'I � -- - � — o � ,-- , � � - T �; N , � _ _.� � � ; � � � � M dic 1 �o _ 4. -= � � 4.,W�� �� ,� � , �.� � � e a �_ ----.. ccNS„i�_ ��� '�, � x—... VA VAC '--- 3 - ��. — C -['i3t ���=; , J i � - L , � J J � _ _ I I � Y4� � � I � _ 1 �4. -3n — �2 �^ _ �� i _ - ^ I I� T I � _ __ � ; ��� ' - enter � C �_.�_� - - �— ��.� � -- � — SA-1 I �� LOOR � ' j .�. . -�� �_.J . ��.. �.r_:_ \ l �J �L �V . I � ' ' i, i i e ' " CONNECT 2" VENT - - ��, �. _�. , , ��, o i i � � � nm rrn - �'. � 1 "CW AND Yz"HW �ER � � � � - � - _ . � � ' � i �� ..i. � i i �i � � � TO VENT RI , � �I , �'�. - - - - � �, � i fi 2- - - - - -- -- - - - - h N � � i - i AN i �_ _ �� � �; � , p , i � ZVB � . ', i . �'� TO WC 1 AND L�t � � � „ � . _ _2" W DN. � I � 3/4' r I : ?- - -I= �- ?-' I I � - oT�- i I � ^ J � � � �. �" �_ � 02 � � _ - ' _ I ',' 4' W BELO� ¢ -- �4 ^ .. � - - - � ,, Y �I � N ��.— .—... .. . .. CONNECT TO (E) � yZ" i - I i J � � � J •-�:_-. . ... . - CTOR .- Ki - � . _ - n � �I, � ' \3 � TVAC , . �� � / f I � 1 2EWORK �'� '-'�� �2 �� � � i� S- 2 � - - ', i � KEY NOTES . ' � p2 ` " �4k as. y` \\ ' . TO � � � i VAC ��- �, \� _ � 3\ y� � � � 1y `J � �\ TE LOW �._ � �'� o � � - �_ � I \ �' . � ,i � .. _ . . � . � � �--� � _.- - - - - - -: _ � - � � _ -J __ First Floor �1 3�4' COLD WA1ER DONM IN WALL TO STEAM GUN CABINET, SEE DETAIL ON �� � , i � i � � � � ��� � ' �'� _—„_- �'i \ - - - - -- - - -- - -- - - i i _ � REPLACE 1Y� VENT - — � — 2 RELOCATED ZONE YALVE BOX. � I - �- � 2 Z � • SHEETM4.01. - _ I ��---_ --a" �,_�� Nuclear Medicine _ _ � - -- - - - - r - - - - - -- - - - � O 1 �� ���� - � � � � ,�"I '^ � . MA � J W EW 2 . ...... -�__ 1,,. .�� - A�F _� _�r� i s aa nne , O� '�� 1' �Z ' �� �A -��i� �.�,i,. a-'� I , Qm Q _ . —� I i � , O3 REFER TO ARCHITECTURAL DRAWINGS FOR LOCATION OF OUTLETS. ° � �' � i � VAC VAC a S P C R �i 1 I 1 O � �i I ' - I . 2" VENT UP ' �b — .. . __ _ . .� I I .,y� ��i�-�� n� i +h" lh� ��� u . 02 ... �--�------a� , I�_�\ I�I II� � I I �- ; , 3 4� , � i FF ., _ . � ._ - ^� � ...� � .. ?'� 1 I, , �11 3 n c M_o ie ' �\ _.. — / _ —�- MA , ._ _ _ — — ' � � , , . � � � . I � ^ ' � . , �� �� , ` �' . � y � � _ � '� , �� . � .. I",C r I � �-_. � � �I 1 2" a I � i O o i � ^ �� I , I_.. ,— �J_ Z � �� _ ' 2 FS-� i I I�_ I _� -I J � �� -T� I _ � � i �- 4� z�a � n � — I , ' � i I r �-� —.— � _ .-2�— � _:-:'�-' IL ' 181 W. Meadow Drive , , w�-� . � � � � � � , v, � =� —. �^ �-2 �J � I Y t z� � _ — _ ,• I Vail , Colorado r � � , i � � � � � � � SH � � - i � � � — . . , , , I 1 1�2' 3" W. DN. AND � �—.. . � � *. � CONNECT T E ,_ _ / /I ' , � -- - �-� - ' � \ ' I 4" W BELOW.(j � . � . ... _�_ � i -vJve / i_ i 2" �ENT �P : . —..— 81657 ��� -- � �- � � -_----- -- -- f-- ---_ -_J � 1 1 2_V DOWN __--, 1 � PRONDE SHOCK ABSORBER I I _ � ��� I2 ^i i _.- _- i _ _ i��2-^ , I��"r��-�*�-�- ,� L 2"FS-1 2'f5-1 �,� I � ON CW PIPING SERwNG WC i � - L -- - 1 ! � � � �� i ` _— I .�_ , �� � � �< i �... — - 1 i � I - - - I _. — N _ . � —.�- i � Ii o . . .—... g_L! i-.. ,.L._ . ... .. . _- .. .._ . .—.. .- �1 � t - - - . . , . , . . .. . —... . --- .. s.- .—_... . _—_ +— . _—. . —_ __�.� ... — — . ..—.. .—. ._ P ! � ¢ /�'...�i ��"�- — �. . . '� Y2 I I I � I �. �> I� � i ' ' '' �°"E�T°?'E) , � �' ! ' � � � PARTIAL FIRST FLOOR _ ' � ''' � � i � ! � �� � . a° ��ow-- �, —. � - �� , ,�. ! � — � � I �,� � i i II Vs � Ii — , I � �� � C i — = PLUMBING PLANS � - � '— _—_ �- ' n �_ � � \, — —. . — — --.. .—. —... _ � ' �— ' � � �� i � — �, � �^ s,e � '�— . ...—. _ ... . —.. — _. .—.. .. _. ..— , � _ i .. ... .�� �I'-�=. �I, �.. .� , -' �� � d0 — � S - � � � t— TO BULK OXYGEN . S-1�.. ?` _�, - �� / - TANK /' � , ,..-� , , . ,. ' -_ � —� . :—:..'��-- i ` '"'°� , /s-�� 'I��Ii 1,�--� ' DATE 2 APRIL 2007 i�r� _ � . ,�r—IJ �� , II . �— i .� � J —_ - ' � " I � . I �- -�, DRAWN BY MWd G� PARTIAL FIRST FLOOR PLUMBING PLAN CHK' D BY WAT SCALE: 1 /8"=1 '-0" SHEET FILE P—PP1 � CAPYRIGHT 2006 6Y OMVIS PARINFRSH�P P.C.. ARCHrtEC15 SHEET NUMBER: M5 . 01 Cator, Ruma & Assoc. FILENAME: P: \VVMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\PLBG\P-PPI .DWG _ M5.01 PLOT: OS/31 /2007 � 9: 14om REV: O5/30/2007 CAD: MJohnson XREF: bgl .dwg ppl .dwg tb.dwg , � ' • - � Archit ts 2301 BLAKE ST., STE. #100 DENVER, COLORADO 80205 303.861 .8555 F.303.861 .3027 0225 MAIN STREET , UNIT C101 EDWARDS, COLORADO 81632 970.926.6960 F.970.926.8961 C.aTOa, Riz��A � A�sc� c�.aTes, Co. COKSUCCING 41EC[ lAA'ICAL/ELEC'IRICAL ENGI�'EERS 1550 Dover Street . Sulte Two . Lakewootl, CO 802153132 303,�232-6200 � Fex 303/233-3701 cra(o?calorruma.com . �^nvw.catorruma.com ' � ISSUE/REVISION DATE NO. � � (E) BOILER �� '�� � ' TOV CODE REVIEW 6-01 -07 M i I i i IQCY ME II ; E ` EC - � � 2008 --� ; 20 � 7 � � , � � I� , , , � � � I �, � � �, � „ � , , , , I i I � , � , I I I ' -- ------ ---- - - - - - - - - G - - - - - - - - °- --- --- - -- --- - - - * -- - - - -- - --- - - - I - - - - - - i I G - � I I i '� - - - - - -- - --- - - -- ----------- - - - - - - - - - - ---• I - - - - ° � � I I I I � � ' GAS LINE ' ; , GAS LINE ��� ; ON ROOF ��� � ' ' ; �� ON ROOF � I � , � , � � I I � � ' I I � (E) WATER HEATER � ; , I �� I '� !, (E) WAiER HEATER � � �I , ,. � � � � � � � � � � � � � � I - - � � �" " " " " " " _ I" ' _ _"_ '_ "_ ' r "" "_ � ' ""' "'" "" '. r'_" "" " " " ' _ " ' T" ' _ ' _ � � i � " ' '_ � � __' ........... ._ . ..,... � _.. .....- .........- "' .. . --.... ._ .... .._'__ _'..._ . .... . " -'....' ___' _"'..._ i 6�� � � i 6�� � , __'.. ....-" -_...... ...._. ._. ...... _� ' _"_' _" -" _'_ '_ i __T. .._. � " I� . �/ � R . ..... . .... 3 x � --- - - - 6,� �---� �-�--- -.._ .. .... .._ SB , �i ` - - ° -y -- - - -6^ �� � -_ . __. ..... ...._ .. . ` - -- -' L- � 10 0 . � � Z . --, ._. gg I � G �2 � G- - 3 �� � 10 0 E1 3 E1 !, _ NaX 3 1 � �_7 �_ I ' � � � T EF-1 W/ WEATHER HOOD. T EF-1 W/ WEATHER HOOD. '" rn � �� �� \ p � �p" I . 2 � �2�� -`--- ._ 10"0 10°0 _.. ' ' . � — 36X14 SB ' 36X14 BF i...... . ._�� .� e �.. . 2 UH i, BF UH Z SB � �� 2 _ ✓ �� 2 . ✓ . _ n II �I 3�4 T � 12" B.B.S. ! 3�4� T c� � 12" B.B.S. i • �� 2000 CFM � �� 2000 CFM � � �� � � --�— t°� --.. ._. j�o ,NI'I ._... M I _ O O i � �«�I � � . i � �., � (E) 14" FLUE UP. I I O i 2 :. � (E) 14" FLUE UP. p � - - -• \ � � � - - $ �.:.. 500 CFM I . ,l . � ' iD � O �i V �I �O - -- - -2 / - .. �. ,. . 500 CFM I '•�\ ,' , V I J i� � �- -- - - � '� '�`'•� , , � � � ' M e , .,; ; , � �� , • � , � � 3 ' . � � —, � : `. I ��, i 1 �-� � 6 , o�� � � � -� _ E , o��� Medical � w BF � / '; !I \\ '� N BF " \ . � . .. e �F.S. / / , , �n .. ` (E) 10" FLUE UP. '' \ e �F.S. ; I M� ` (E) 10" FLUE UP. �'� � % i i'1 % i �\ ' � � � n r n n � Ce te � M M'. i I i i � � I i � � i _... .. . ._ .. . ._'_ """ . .. . .. _...... _. ... ..__ . . . ..._. .... _.._.._.. -... ._ ..._ ...._. _. _ -- ".... . .. . .. . _' _ � -- ' . . ... . . �__._ . ..._.._ . . . . ._._ .. .. .. �'�. _ .._.. ""- r _....- _' ' � ' C A � I i, 38xt4 � r � L � " CLr._ A ��' ' 1 38x14 I ....... .... ... — � . ,, _.� 3 4" ' '�, _.. _..... ._ .�, �, �� � i � 12" A.F.F. I ✓ � �/ � 12" A.F.F. � . �/ 3�q�� . . � II il � � , _ , � � �' _ _.. ..._ � -� 'I� -- I % C` c� �- � I 2 O�i � II �I I J �/ ..._� �I �._� � I I I I II I I I I I • I I _.. _., ) I I� � - Fir Floor - st . . _ _ T � _ I , C _ . :: � �` ' r�' �' '' I �I r� — - r� '' I � �' � , `-,' ' `-' � I i r� __i i , �, S - '�, � � J I \ Nuclear Medicine G1J PARTlAL SECOND FLOOR HVAC DEMJLlTlOf� PLAN G� PARTIAL SECOND FLOOR �;VAC PLAN SPC Remode ! a SCALE: 1 /4'=1 '-0" b SCALE: 1 /4'=1 '-0" DEMOLITION 181 W . Meadow Drive GENERAL NOTES : GENERAL NOTES : KEY NOTES : Vail , Colorado 1 . CONTRACTOR IS RESPONSIBLE FOR FIEID VERIFlCATION OF ALL IXISTING O1 CONNECT NEW 10"0 FLUE TO EXI511NG, FlELD VERIFY EXACT LOCA710N. 8 � 657 1 . EXIS7ING ITEMS 70 REMAIN ARE DENOiED LIGHILY UNLESS OTHERWISE NOTED. ALL CONDRIONS PRIOR TO COMMENCEMENT OF ANY WORK. ITEMS SHOWN HATCHED OR CROSS HATCHED SHALL BE REMOVED UNLESS O2 CONNECT NEW 1 1 /2' GAS LINE AND ROU7E AS SHOWN TO NEW BOILER. OTHERWISE NOTED. 2 . COORDINATE WORK WRH ALL TRADES. Z • CONIRACTOR SHALL NOT SHUT—OFF OR PUT—OUT OF SERVICE ANY SYSiEMS OR 3 . CONTRACTOR IS RESPONSIBLE FOR SECURING AND WFATHERPROOFlNG ANY ROOF Q CONTAINMENT CURB AROUND EQUIPMENT, RE: ARCHITECiURAL. SERVICE W1IHOUT FIRST COORDINATING W17H 1HE OWNER. OPENING NOT COMPLETED DURING WORKING HOURS. 3 . IT IS THE RESPONSIBILITY OF iHE CONiRACTOR TO VISIT iHE SITE AND 4 • COORDINATE ALL DUCiWORK AND PIPING WITH EOUIPMENT, STRUCTURE, EfC. UNDERSTAND iHE E%TENT OF THE REMODEL WORK REDUIRED PRIOR TO BID. NO EXTRAS N1LL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS 5 . CONTRACTOR SHALL BE RESPONSIBLE FOR DEACTNATION OF ROOF—MOUNTED INDICATED BY 1HE CONiF2ACT DOCUMENT. EQUIPMENT AND ASSOCWTED INDOOR EQUIPMENT. ONLY ONE UNR SHALL BE TAKEN OUT OF SERVICE AT ANY TIME, WITH REMAINDER OF UNRS LEFT 4 DEMOLITICONTO FACILIDTAiERAILL WORK �INDCAITED BYHiHEXCONiRACTNDOCUMENT. CONTRAIC OR. COORDINATE WITH GENERAL CONTRACTOR AND ELECTRICAL PARTIAL SECOND FLOOR 5 . PRIOR TO COMMENCEMENT OF ANY DEMOLITION WORK, VERIFY EXISIING CONDI110NS 6 . INSTALL ALL EQUIPMENT PER MANUFACTURER�s ���oE��NES. ENLARGED MECHNICAL AND NO11FY ENGINEER OF ANY DISCREPANCIES FOR RESOLU110N. 6 . ALL IiEMS IDENTIFIED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIREN PLANS UNLESS OiHERWISE NOTED. REMOVED 11EMS SHALL BE TURNED OVER TO 1HE OWNER UNLESS OiHERWISE NOTED AND STORED IN THE AREA DESIGNAiED BY THE OWNER. REMOVE FROM SIiE AND LEGALLY DISPOSE OF ALL IlEMS THE OWNER DATE 2 APRIL 2007 CHOOSES NOT TO ACCEPT. 7 • WHERE EXISTING PIPING, T.C. NBING/`MRING ETC. ARE TO BE REMOVED FROM DRAWN BY MWJ WALLS WHICH ARE REMAINING, THE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL coNOinoNS. CHK'D BY WAT 8 . WHERE EXISTING PIPING TO BE REMOVED PASSES 1HROUGH FLOORS, THEY SHALL SHEET FILE P—HVQ2 BE CUT BACK TO WITHIN CONCREiE AND FILLED W11}i GROUT TO ACHIEVE A SMOOTH AND EVEN FINISH Wlhi CONCREiE SURFACE. NO?E THIS WORK SHOWN AS EXISTING CONDITIONS pppypqM yppy gy py�NS PARINERSHIP P.C., uta�rtECrs WAS TAKEN FROM OWNER FURNISHED EXIS " IVG �ON � - 0vS Ai = ��i0w� w' TI- DRAWINGS BY CATOR, RUMA & ASSOCIATES, SHEEf NUMBER: �_' ;; �� ? � NE w= ' G - ?. C0. CATOR, RUMA & ASSOCIATES, C0. IS NEW WORK INCLUDED IN THIS CONiRACT NOT RESPONSIBLE FOR THE ACCURACY OF M 6 ■ O � IS SHOWN N7TH HEAVY LINE WEIGHT, ANY INFORMAl10N OR THE ADEQUACY, CONNECTION OF NEW WORK TO EXISTING SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN WORK IS DESIGNATED BY " � ". AS EXISTING ON THE DOCUMENTS. Cator, Ruma & Assoa FILENAME: P: \WMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\MECH\P-HVQ2.DWG _ M6.01 PLOT: OS/31 /2007 � 9� 14am REV: OS/30/2007 CAD: MJohnson XREF: bg2.dwg tb.dwg HVp2.dwg ' � ' • - � Archit ts 2301 BLAKE ST. , STE. #100 DENVER, COLORADO 80205 303.861 .8555 F.303.861 .3027 0225 MAIN STREET . UNIT C101 EDWARDS, COLORADO 81632 970,926.8960 F.970.926.8961 — .. . _ —. . r— — � — � -.� � , -- -- � � - -� ._- I ! �----��-- . , L C,�aTOii, Ru �1,a � Associ .�,TES, C.o. . , CO\SULTIKC; MGCHANICAULLLCTRICAL GNGINECRS , � 1550 Dover Street . Suite Two . Lakewood, CO 80215-313'L i � I , , � � 303l232-6200 . Fa■ 3031233-3701 '�I cra�catorruma.com a www.:arorwma.com � � I I (E) BOILER (E) BOILER J ISSUE/REVISION DATE NO. 0 � I I i TOV CODE REVIEW 6-01 -07 , I PHARNA � " �v� E -i E '_ ECT iqCY �'� � �I � � � CT I � 401 � � 008 � C07 � 200 � �— 2 � 07 _ j � �, I � � � � I I � � �I � I, I I (E) WATER HEATER ' i O I �E) WATER HEATER O I I I I i uuuw -- --- —_-�_ II I - - — �L _ . I I _ � 1. --� _ � ��. ..—� —� --- — _ ..-- � -- --.. .—. .. .. _—. n _ . n � i 101 a. I -- .— ..— . - - - - - - - - - - - - - - � /� � PRV STAiION n BF �'— SB � PRV STATION n BF —'�'— 5B � s� � � e � '�J � I� � � 3 � � 3 I � � � � q II - - � ' II - - � �I __' I � BF - � I I I BF - � r J � I I I r J � I 2'MPS DOWN a I � � � I a I ( � � I � � 3 4 i 1 ^ BF — � I 1 1 /2° J a 3 4 i ' �� BF � � I 1 1 /2° � — ��� sv _ ' ' �� 2 u'H � I ZF � ^ I r�� 2 UH �I I I Z � � I I - � � � � , I I ' �� � � � � � � � I � � � � T � � , I� � T • - 3 II 3 JA � 3. SB I 3" BBD SB Va� l �1� — I a r - i - - S R- r - - - - - - - 1 � - SPRL7'+�' � 2 �--- — N r - i - - R- r - - - - - - -L � - SPR z � I I PS � I w I 1 1 2 ' —� . ^ g � I PS � I I — BF � � � � � ; i � i Valley Ni r' �M � C-- -� - - -2 � a i� I P � M I C- - - � -3 � a � a � � , a � � � , BF � -�. ��� i� �, �i � � � � a; � -�. ' � �� i �� Medical � � � u �' � C- - SEPARATOR � ' I C- SEPARATOR 1 1/2 � � i I � F.S. I � i � � F.S. � � �I L I BBD 11 2" 71 � 2" � � � � Center i J _ L _ _ _ J _ L _ _ _ �- � I BBD BBD � i �— __� �I --- — --- — � 1 � — - --. s� _ � I — —._ I� —. . _. � I C L ` A � _ I � 'I� _ _ -- I� I I �— _ I, C I` � A �� I Ir--I i BYPASS�LJNE I I I `\ -� P I C ' �J J I-'{ �J ILII I I IL�. I li � � Ll I I I I . I � �-�' � �� � � � � � �� � I �� � 2e � � � 2 � 5 � � � � � '� i � . � I � ' i li l —� i ! I iI � I ' I i �,- I �� I � � �� --� 'I "� First Floor I � � ._ � `�.- CTIO �\ � I �-, �—J � I � ._ SECT10 \' �I I � I � -�. � � I �- � i Nuclear Medicine G� PARTIAL SECOND FLOOR HVAC PiPING DEMOLITION PLAN G� PARTIAL SECOND FLOOR HVAC PIPfNG PLAN SPC Remodel b SCALE: 1 /4'=1 '-0" b SCALE: 1 /4'= 1 '-0" DEMOLITION 181 W. Meadow Drive GENERAL NOTES : vail , Colorado 1 . EXISiING ITEMS TO REMAIN ARE DENOlED LIGHTLY UNLESS OTHERWISE NOTED. ALL 81657 IiEMS SHOWN HATCHED OR CROSS HATCHED SHALL BE REMOVED UNLESS OiHERWISE N01ED. 2 • CON1f2ACTOR SHALL NOT SHUT-OFF OR PUT-OUT OF SERVICE ANY SYSTEMS OR SERVICE N7'IHOUT FlRST COORDINATING W1TH THE OWNER. 3 . �7 IS THE RESPONS161UTY OF THE CONIRACTOR TQ VISIT 1HE SITE AND UNDERSTAND THE EXTENT OF THE REMODEL WORK REQUIRED PRIOR TO BID. NO EXiRAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END RESULT AS INDICATED BY THE CONiRACT DOCUMENT. 4 �EMOLIi10N TO FACILITATERAILL WORKCNDCAITED BYHTHExCONTRACTNDOCUMENT. PARTIAL SECOND FLOOR 5 . PRIOR TO COMMENCEMENT OF ANY DEMOLI110N WORK, VERIFY EXISi1NG CONDIT10N5 E N LAR G E D M E C H N I CAL AND NOi1FY ENGINEER OF ANY DISCREPANCIES FOR RESOLUiION. 6 . ALL IIEMS IDENIIFIED TO BE REMOVED SHALL BE REM04ED IN THEIR ENTIRETY HVAC PIPING PLANS UNLESS OIHERWISE NOTED. REMOVED ITEMS SHALL BE iURNED OVER TO THE OWNER UNIFSS OiHERW1SE NOTED AND STORED IN iHE AREA DESIGNA7ED BY THE OWNER. REMOVE FROM SITE AND LE6ALLY DISPOSE OF ALL IlEMS THE OWNER CHOOSES NOT TO ACCEPT. DATE 2 APRIL 2007 7 . WHERE E%ISTING PIPING, T.C. 1lJBING/WIRING E7C. ARE TO BE REMOVED FROM DRAWN BY MWJ WALLS WHICH ARE REMAINING, 1HE WALLS SHALL BE REPAIRED TO MATCH ORIGINAL CONDITIONS. CHK'D BY WAT B . WF{ERE EXISTING PIPING TO BE REMOVED PASSES THROUGH FLOORS, THEY SHALL BE CUT BACK TO NAiHIN CONCREIE AND FILLED WITH GROUT TO ACHIEVE A SHEET F1LE P-HPQ2 SMOOTH AND EVEN FlNISH W1TH CONCREiE SURFACE. NOTE• THIS WORK SHOWN AS EXISTING CONDITIONS Qpp{q�GFR 2006 BY DAVIS PARINERSHIP P.C., u+cHrtccrs WAS TAKEN FROM OWNER FURNISHED EXIS-� tiG COND ' TC� S AR� S'�ICWU wI �H DRAWINGS BY CATOR, RUMA & ASSOCIATES, SHEEf NUMBER: LIG�' T LIN = W�' GHT. C0. CATOR, RUMA & ASSOCIATES, C0. IS NEW WORK INCLUDED IN THIS CONTRACT NOT RESPONSIBLE FOR THE ACCURACY OF M 6 ■ 0 � IS SHOWN W1TH HEAVY LJNE WEIGHT. ANY INFORMATION OR THE ADEQUACY, CONNECTION OF NEW WORK TO EXISTING SAFETY AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY WORK SHOWN WORK IS DESIGNATED BY " � ". AS EXISTING ON THE DOCUMENTS. Cator, Ruma & Assoc. FlLENAME: P: \WMC\2006-367 NUCLEAR MEDICWE REMODEL\CAD\MECH\P—HPQ2.DWG _ M6.02 PLOT: 05/31 /2007 � 9: 13am REV: 05/30/2007 CAD: MJohnson XREF: bg2.dwg tb.dwg HVQ2.dwg HPQ2.dwg ' � ' • - � Archit ts 2301 BLAKE ST. , STE. #100 DENVER, COLORAD080205 303.861 .8555 F.303.861 .3027 DATE March 30. 2007 dos: wMC Nuc�ear Medicine Remode� 0225 MAIN STREET . UNIT C101 JOB N0. 2006-367 EDWARDS, COLORADO 81632 Bv Michee� dohnson 970.926.8960 F .970.926.8961 HIGH PRESSURE NATURAL GAS SIZING WORKSHEET UbliryContact OWNER Comments Date Contactetl. Marh 29, 2007 ForPipe oi3" tlia andLaryer INPU! OUTPUT eatCOntemolGas�, et CFHlnput: 9,936 Total Builtling Oemantl (BTU Inpotvalue�: 604b,0 equlred Pipe Size (In,): y,37 Atm. Preccure pn Denver we 1E.Y pci)�, 10.8 PIpB SIZB (In.) CepaCity (CFH) etenng Pressu re � Meter Outlet (pai)', 3 10.531 ebveryPrecaure � MOCtRemoteUnit (psi): 0 y 39.508 peciticGravityotGas (inDenveruseO.Wj: O6 6 111,663 Tota� EqurvaiemLengiholPipe �X�: 39 B 25340: 10 a59448 'NOte'. Pipes¢eswerecalculatedusingtheWeymouthFOrtnula ]4],11C 'NOIE' $iiiOQ QOOC �OI pIB660fB5 Ql2dIPllhd� 1.$ p61Q , 1/ l 1 ) T{�,( I ^ 1 � (`` \ 1 I � = AbaolmeTemp. T1 = FlowingTemp = T + SpF P = Absol�tePressureinpsi pp = OutictPrcssurc D = �ipes¢emmcbes \: : \T� � I\, I \ 1 � �.`'l :\ i'� .).7� 1�, � .-1TC�, �`��. O = FlOwmcFh G = Specdmpre�iy p� = inietvressure � = Pipe �en9mimm�es ('O\'Slll 'I'I\G \1l:Cfl:1\ I( ':11 .'lil.l'!l " I'RIC '�\LfKUI\IF:ItS WeymouthFOrmula 0 = I18.OB: vIT � Pp.r �(Pt? - P:: xDi18911:IGvTixLi1(v:� '. 550 Doe�er Street . Suile lwo • Lakeveoutl, CO BU215-3132 3U1'[32-620U � Fax 3U�!233-37U1 ForPipeUntler3" tlre. CfBi'ilGBS]TU01d.J0iT � WW�n'tZtUffuf'1dL01t1 INPUT OUTPUT eaicomemorca:. ei CFHlnput 4,685 ISSUEIREVISION DATE NO, _ ..__ . . . .. .. ._. Total BuilCing Demand (BTII Inputvalue)�. 3795.0 Requtretl Plpe Slxe (In.�: �.gg Atm. Preasure (in Denver use t]3 psi): 10 B Plpe SILe Qn.) Capetlty (CFH) eterinqvrecc�re � metero�uet �Pai�: �� �� � � ��� �� �� � i;z �, iae TOV CODE REVIEW 6—�� —�7 ..... .... . ... .... . .. . .. eliveryPrenaure � MOStRemoteUnif �pai�: 1 , 3,q ,, 410 pecilic Gravrty ol Gae (in Denver use0,67)�, 0.8 � �., Bai TotalEquivaleniL.engtholPipe �tt)�. 16 � pq '' 14]0 1 1 �7 �. 2,318 •NOte'. Pipesrseewerecalculetetlueinqt�eCoxbrtnula z i 4,959 'NOte'. SizinA Bood for presnures pmamrthan 1.5 psig Z �,� � 8,313 Pt = Inlet Pressure L = Pipe IenA�h in@iil�ipe tliameter m mcbes O= Flow m CFH G = SpeciLC pravi� = Outlet Presaure Cox Formula'. O = 133.3)x �(P12 � P22 e D (S�p( G t L�)�12� sn G ROOF a, z , /z° Z 5 101 } V�1 � � � � � U � 4� � Vail Valley Medical Center 1265 MBH INPUT 1265 MBH INPUT 1265 MBH INPUT SB ZB 3B 6" ee 595RMBH INPUT � �� SERVED INCINERATOR G � 34 MBH INPUT 199 MBH INPUT THAT HAS BEEN REMOVED Z� 2ND FLOOR / ROOF " First Floor MAKE-UP Nuclear Medicine AIR UNIT 40o MBH SPC Remodel 181 W . Meadow Drive Vail , Colorado 81657 � 4" EXISTING GAS METER � �� � 3� MECHANICAL GAS RISER DATE 2 APRIL 2007 DRAWN BY MWd CHK'D BY WAT WH B B tR e SHEET FILE P—FD 625 MBH INPUT 1 ,200 MBH INPUT 1 ,200 MBH INPUT 1 ST FLOOR CppYFtICHi 2005 6Y �AVIS PARINERSHIP P.C., ARCHRECTS GAS R I S E R D IAG RAM SHEEf NUMBER: SCALE: NONE 7 . Cator, Ruma & Assoa FILENAME: P: \VVMC\2006-367 NUCLEAR MEDICINE REMODEL\CAD\MECH\P- FD.DWG _ M7.01 PLOT: 05/31 /2007 � 9: 13am REV: 05/30/2007 CAD: MJohnson XREF: tb.dwg GENERAL ELECTRICAL LEGEND SYSTEMS LEGEND ' SYMBOL DESCRIPTION �"ot m eNneda �ietee eaow a�� SYMBOLe e�wl^�e) DESCRIPTION SYMBOL DESCRIP110N �"ot o�� epnbols Iistad bNo. aroSTMBOL a�l^as' DESCRIP110N DMSION 78 - ELECTWCAL E. SWITCHES SHALL BE OF THE SAME OR LARGER AMPERE RATING A3 THE CIRCUIT PROTECTIVE . LIGHTING 0 7�.EPHONE TERMINnI CABINET C 5 CdABINAnON C�OdC/SPEMCER OUTIET SECTION 1E010 - BA81C ELECTRICAL REQUtREMENTS DEVICE. A. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH LOCAL AND STATE CADES, AND LATEST F. FUSES SHALL BE OF SAME MANUFACTURER. � � � } � RECESSED FLUORESCENT LUMINNRE, LAY-IN O RECE55 MOUNIID W�Il u1MINAIRE T-r TQEPFiONE TEPoAINAL BACKBOARD QS � PACING SY51F1� SPEAKER 'N' iNDiCAIES MU9c Sr51ElA ONLV B. CO TRACT�OR SHALEPAY FOR AL�L FEES. A �LUMINAIRES SHAL HAVE MANUFACTURERS STANDARD FINI3H UNLESS OTHERWI3E NOTED. � � Arch � t l.S RECESSE� Fl.uatESCEHi ul�UNaRE, MNCED K PORCEWN KEtl.ESS uMPHOLOER, BRYU�IT /5228 w/ �OOW A�B 7ELEpHONE W'RE7 w-WAU, P-v�Y V vowME Ca�ma C. CONTRACTORSHALLPREPARECOMPLETEASCBUILTDRAWINGSINDICA7INGALLADDENDUMS, B. LUMINAIRES � �PC I.F. LAMP. 'PC INOICATES PULLCHAIN � CHANGE ORDER3, MAJOR CONDUIT ROUTINO, FIELD CHANOE3, ETC. 1 . FLUORESCENT LUMINAIRE3 SHALL BE CONNECTED WITH FLEXIBLE METAL CONDUIT IN � SURFACE OR PENDANT AIWNIID UIMINAIRE ,a � � 1RAdC L1CH11NC � 1ELEPHONE Ou7tET, FLOIXt MWN7ED OM MICROPHONE STAIION D. CONTRACTOR SHALL PREPARE THREE (3) SE7S OF MAINTENANCE MANUAL3, INCLUDING ALL ACCORDANCE WITH THE NEC. WARRANTY INFORMATION, AND SHALL INSTRUCT OWNER ON OPERATION OF ELECTRICAL Z• LUMINAIRES SHALL BE IN3TALLED IN ACCORDANCE WITH THE NEC AND MANUFACTURER'3 I--�}� SURFACE OR PENDANT MWNTED 51RIP OR INDU51FtIAL LUMINAIRE 4-P EIAFRCENCY LIGHTINC UNIT �TP TFIEPHONE/POWER POLE OI INTERCpA STA710N $YSTEMS. RECOMMENDATIONB. e 9iADINC INDICATES EM StSTEM, LO'AER CASE SUBSCRIPT IND�CA7E5 y 3, SUSPENDED LUMINAIRES SHALL HANG EVEN REGARDLESS OF UNEVEN OR SLOPED �A Sµ�Tp{ING UPPQ2 CASE SUBSCRIPT INDICATES WMINAIRE TVPE TYP � �T LICHT, MROWS AS INDICAIED, FACES INDICATED BY SHADINC D DATA WTIET � DOOR CANTACT SECTION 16110 0 RACEWAY8 CEILINGS. SURFACE MWNTED CEILING LUMINAIRE A. GENERAL 4. EXIT SIGNS SHALL BE CONNECTED TO THE EMERGENCY LIGHTING CIRCUIT. 2301 BLAKE ST . , STE. #100 � IX7ERIOR BOLLARD LUMINAIRE ON 9TE PLAN � � MOUNTED LUMINNRE DATA WRET, Fl.OIXt MWNTED CR CARD READER DENVER, COLORADO 80205 1 . RIGID, INTERMEDIATE METAL AND FLEXIBLE METAL CONDUIT SHALL BE GALVANIZED STEEL. C. BALLASTS AND ACCESSORIES I-Q SURFACE AIWNTED WALL UIMINAIRE �C SPOT ucHT � CDAIBINATION TElEPFiONE/DATA WT.ET MD �R S iR-INFR m CU9R UCiRA50NIC, IR S-Cp.�BINATiON 2, ELECTRICAL METALLIC TUBING SHALL BE ELECTRO�CiALVANIZED STEEL, '/. INCH MINIMUM, 7, FLUORESCENT BALLA3TS SHALL BE PROGRAMMABLE R4AID S7ART ELECTRONlC, CBM 303.861 .8555 F.303.861 .3027 3. LI�UIDTIGHT FLEXIBLE METALLIC TUBING SHALL BE GALVANIZED STEEL WITH POLWINYL CERTIFIED, HIGH POWER FACTOR ENERGY SAVING AND PROTECTED IN ACCORDANCE WITH �] RECESS MOUNTED C�l1NC LUMINAIRE m DARNROOM SAFE 11CFiT (TWO COMPARTMENT SHOYM) � COAIBINAl10N TELEPHONE/DATA d1TI.ET, FlAIXt MWN7ED OQ SEWRITY CANFRA JACKET BONDED ONTO EXTERIOR. 0225 MAIN STREET . UNIT C101 4. NON�METALLIC CONDUIT SHALL BE SCHEDULE 40 PVC RIGID PLASTIC. THE NEC. ❑ + RECESS AIWNIED C�L1NG LUAIINAIRE-DIREC710NAL � UNDERCWNIER LICXIING BFi1 ES ELECTRIC DOOFt STRIKE 5. ALUMINUM CONDUIT, AC AND MC TYPE CABLE WILL NOT BE ALLOWED. Z• BALLASTS SHALL BE INTERNALLY MOUNTED UNlES3 NOTED OTHERWI3E. EDWARDS, COLORADO 81632 6. SURFACE RACEWAYS SHALL BE WIREMOLD OR EQUIVALENT. D. LAMPS 970.926.8960 F .970.926.8961 POWER b CHIME SCP SEalRitt CONinOL PudF1 7. WIREWAYS SHALL BE OF THE HINGED TYPE WITH ALL PARTS FACTORY FABRICATED. 1. INCANDESCENT L.AMPS SHALL BE OF THE t30V, iNSIDE FROSTTYPE UNLESS OTHERWISE B. CONDUITS SHALL BE SIZED ACCORDING TO THE NEC BASED ON USE OF COPPER NOTED. � S�NGtE RECFPT�d.E � MOTOR sinR1ER g� BUZZER ML MpGNETIC DOOR �OdC CONDUCTOR3. 2. FLUORESCENT LAMPS SHALL BE 82 CRI OR HIGHER, 3500K TEMPERATURE UNLESS 8. CONDUITS 3HALL BE CANCEALED IN BUILDING CONSTRUCTION EXCEPT WHERE EXPOSED OTHERWISE NOTED. � DUPLEX RECFPTAq.E F- aM--i PLUG-AIOID (MULII-OULET ASSEMBL`� I-� iE�Haot�l ounEr GB GUSS BREAK DETECTOR RUNS ARE INDICATED. 3. LUMINAIRES SHALL BE PROVIDED WITH NEW LAMPS PRIOR TO FINAL ACCEPTANCE. � � DUPI.EX RECEPTAq.E, CRWND FAULT PROTECTION �- wu--� YAREMOLD (SURFACE RACEWAI� o- CIOCK WnET KP KEtvnD 10. EMERGENCY CIRCUITS SHALL BE RUN IN SEPARATE RACEWAY 3YSTEM. SECTION 76535 • EMERGENCY LIGMTING 11 . ELECTRICAL METALLIC TUBING (EMT) FITTINGS: STEEL COMPRE3SION FITTINGS FOR A. EXIT LIGHTS SHALL BE LED SELF-CONTAINED WITH WHITE LETTERS ON A GREEN �� � DUaLEX RECEaT�d.E, ISqA7ED GROUND `� Ca+NECnOr+ i0 PREN1Rm EOUiP�ENT �B ' BE�CON B�BLUE, R-RED RAINTIGHTAND CONCRETE TICiHT APPLICATIONS. STEEL SETSCREW FOR ALL OTHER B,qCKGROUND. CONNECTIONS. BU3HINGS SHALL BE THREADED AND HAVE NYLON INSULATED THROAT OR oOUBLE WP�EX RECEainc�E `'' FlEwBLE vARINC CneLE NYLON BUSHING. SECTION 16721 C FIRE ALARM AND DETECTION SYBTEM 12. LIQUID-TIGHT AND METAL FLEXIBLE CONDUIT FITTINGS: MALLEABLE IRON OR STEEL WITH A. EXISTING FIRE ALARM SYSTEM IS SIMPLEX 4100. � DuP�EX RECFPT�CIE, HALF SvA7CHED CONDUii, CONCEALED NYLON INSULATED THROAT ON NYLON BUSHING. B. PROVIDE NEW FIRE ALARM DEIVICES TO MATCH EXISTING, � DuP�EX RECEPT�C�E, CFJLING MWN7ED - - - CONDUIT, IXPOSED F I R E A LA R M SY ST E M LE G E N D SECTION 18720 [l WIREB AND CABLE C. FIRE ALARM E�UIPMENT SHALL BE OF THE SAME MANUFACTURER INSOFAR AS POSSIBLE, UL (�vot an a�meotr �utae eero� are �eae m tnae erawrpe) A. CONDUCTORS SFi/iLL BE NEW AND UNUSED COPPER, SINGLE CONDUCTOR IYPE. APPROVED, ELECTRICALLY SUPERVI3ED, NON�CODED, ZONED AND BE A CLASS •A' FIRE � DUPLEX RECEPTACLE, ROOft MWNIED - - - - CANDUIT, UNDQtCROUND IXt CONCEAI.ED IN FLOOR B. NUMBER 10 AWG WIRE AND 3MALLER SHALL BE SOLID. ALARM SYSTEM. SYMBOL DESCRIP110N SYMBOL DESCRIP110N D. INSTALL AND CONNECT E�UIPMENT IN ACCORDANCE WITH THE MANUFACTURER'3 � DOUB� ouP�k RECerTnC�, FLOOR MWNho � cor+DUit nrRNING DOVm C. NUMBER 8 AWO WIRE AND LARGER SHALL BE STR4NDED. RECOMMENDATIONS. Fqca FlRE ALARM CONTROL PANEL Rou REM07E DISPLAY UNIT D. GROUNDING CONDUCTORS SFIALL BE COPPER IN ALL CASES. E, FINAL CONNECTIONS TO BE MADE UNDER THE SUPERVISION OF THE MANUFACTURER'S FIELD F� SPECIAL RECEPTACLE -� CONOUIT NRNINC UP E. BRANCH CIRCUIT AND FEEDER WIRING SHALL BE COLOR CODED IN ACCORDANCE WITH THE REPRESENTA7IVE. aNN FlRE AURM ANNUNCIATOft PANEL nSSD NR SnMPIJNG SMqcE DEIECTOR F. f3R0UND CONDUCTOR PROVIDED FOR ALL CIRCUITS. F. SVSTEM SHALL BE TESTED UNDER THE SUPERVISION OF THE OWNER'S REPRESENTATIVE, � SPECIAL RECEPTACLE, FLOOR MOUNTED � CONDUIT CMPED czM GRAPHIC 20NE NAP AIR SAMPLING POINT ENGINEER AND THE LOCAI. FIRE PREVENTION AGENCY. � -�� G. PROVIDE RE-PROGRAMMINGOF SYSTEM AS RE�UIRED TO ACCOMMODATE NEW DEVICES. -�� BRUrCM dRCUIT MoME RUN, NUMe�a OF ARROwS INaCA�s SECTION 78135 o CABINETS, 80XE8, 8 FITTINGS �i iHERMOSi�T p-t,a,5 NUMBER DF CIRCUITS, SUBSCRIPT INDICAlES PANEL k GRCUITS F FlRE N�ARM SYSTEM DEmCE (ANY TYaE) v REI�OTE INDICATIXt uGHT H. REVISE EXISTING ANNUNCIATOR(S) AND GRAPHIC SONE MAP(S) TO REFLECT PROJECT FIRE ❑ ❑ Ri A. CONTR4CTOR SHALL PROVIDE CODE GAUGE SHEET METAL PULL & JUNCTION 80XE5 ALARM AND ARCHITECTURAL MODIFICATIONS. ( �1 OJ JUNCTON BOX, WALL OR CEWNC MWN7ED V� IXtWND But COMPLETE WITH ACCE330RIES SIZED PER THE NEC. I. REPLACE EXISTINO SMOKE DETECTORS WITH THERMAL DETECTORS DURINO CONSTRUCTION C.�T�� R, RLI ��1 ;� U ,'ISSUC I ATF�, CO. �F MANUAL PULL STATION �F FAN SNUT DONN RELAY WITHIN AREA$ OF WORK. M FR B• PULL 8 JUNCTION BOXES SHALL BE FACTORY PAINTED. ELECiRICAL PANELBOARD, CONiROL PANEL OR OTXFR CONSUI"fIXG \4G('11;1:1�i('AI,iF:I.IICTRI(�Al . PNGmrras Q �uNCnON BOX �tooR MOUNho G �p&NET, �s nOhD C. PULL 8 JUNCTION BOXES AND CABINETS FOR EMERGENCY SYSTEMS SHALL BE PAINTED RED, FQ FlRE ALARM DEIECTOR I�IONIZATION, PE�PHOTOELECTRIC �F DOOR HOLDER, MAGNETIC i e on D. OUTLET BOXES SHALL BE ZINC OR CADMIUMOPLATED CODE GAUGE PRESSED 3TEEL AND OF SECTION 78740 - VOICE, DATA, CABLE N BYSTEMS '� 550 Dover Straet . S,aite Two . Lakewood, CO 80215-3132 � Fl.EXIBIf N1RlNG DISTRIBUMM' BOX � MAIN SN1iCHB0ARD/DISTRIBUTIpJ CENTER � THERMAL DETECTOR IF�FlXEO IEMPERATURE, � SPRINKLER FLOW FlRE ALARM THE KNOCKCOUT TYPE. A. GENERAL 303�2326ZU0 � Fax 303iZ33-3707 � s iR-FlXED TEMPERAIURE k RA7E OF RISE TEMP. RA11NG E. ROUND BOXES WILL NOT BE PERMITTED EXCEPT WHERE SPEGFIED, 1 . CABLING FOR VOICE DATA AND CABLE N ARE TO BE PROVIDE BY OWNER'S VENDOR. r.ra(,vca;nrtum.�..:an . www caturr�ni� cum Q MOiOR ❑i nt�NSFORMEii F. WEATHERPROOF OUTLET BOXES SHALL BE CAST ALUMINUM WITH THREADED HUBS AND � uv R �ME DE7EC70R uv-ULrnAMaET, IR-INFltutEO Q TS saaiNKLER 7u.�PQt sxiTCH CONTRACTOR SHALL COORDINATE REQUIREMENT WITH VENDOR. � Dlsca+r+ECT Svniai (Nar-FUSeo) ci cuRRENT iRarsFatMER C�eiNei SCREW MOUNTED GASKETED COVERS. 2. CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM CONDUIT, RACEWAY3 AND OUTLETS �s R DUCT sMa�E DEhCTat 5-SUPaLr, R-ReiVRn � FS SPRINK�a Fl.ow swiTCH G. OUTLET BOXES SHALL BE INSTALLED SECURELY AND PLUMB WITH BUILDING LINES IN FOR THE FUTURE INSTALLATION OF TELEPHONE SYSTEMS. � DISCONNECT SINTCH (FUSED) � unutt Memt b FlRE ALARM VOICE EVACUA710N SPEAKER ACCORDANCE WITH THE NEC. 3. RACEWAYS SHALL BE RIOID CONDUIT OR EMT. ISSUE/REVISION DATE NO. o-T BEw TPE SMqcE DE7EC70fi - 1Rµ5MI7lER OO 'b' INDICAlES RISER qRCU1T DESIGNA710N H. OUTLET BOXES SHALL BE SUPPORTED INDEPENDENTLY OF THE CONDUIT SYSTEM. 4. PROVIDE J-HOOK SUPPORTS 4 FT ON CENTER ABOVE ACCESSIBLE CEILING FOR LOW I. BACK TO BACK OUTLETS SHALL NOT BE PERMITTED, VOLTAGE CABLING. � COAIBINATION 9TM1ER/OISCONNECT GANN CENERATOR ANNUNqATIXi PANEL �� gEAM 7ypE SMOKE DETECTOR - RECEIVER � FlRE AURM VOICE EVACUATON SPEAKER (W/57ROBE) J. TELEPHONEOUTLET33HALLBEMOUNTEDA73AMEHEIGHTASADJACENTRECEPTACLE TOV COMMENTS OB-O 'I -O� Qj q 'b' INDICAiES RISER GRCUIT DESICNATON END OF DIVISION 18 OUTLETS. SN7TCHING F❑� FlRE AURM STROBE FQF TELEPHONE JACK F.FlRDAAN�S, W�WARDFNS SQ $INGLE POLE SN7TCFi (SUBSptIPT DENOTES SYATCHING) �� LOW VOLTACE SN7TCH F FlRE ALARM Hq2N F FlRE AURM MONITOit MODULE SECTION 78742 - ELECTRICAL CONNECTIONS FOR EQUIPMENT �4 ❑ MM A. MOTORS 1l2 HP OR SMALLER SHALL BE RATED 115V, SINGLE PHA3E UNLE33 NOTED S1 TWO POLE SN1Tpi � vnRInBLE SPEm SNITCH � � FleE uARM CHIME FQ � FlRE ALARM CONTRO� AIODULE B. MOTO SILARGER THAN 1/2 HP 3HALL BE RATED AS INDICATED ON PLANS. S3 iHREE-w�v SN1Tai �P E1�L090N atoOF SN1TCH � H�5 SRE SPEAKER�7ROBE/COMBOINRA7/ION,�CE COMB�EATI��E CdABINAnON EOLR END OF LINE RE95TOft C. PROVIDE MAGNETIC MOTOR STARTERS FOR ALL THREE PHASE MOTORS AND MOTORS INTERLOCKED WITH EXTERNAL DEVICES. S4 FOUR-WAY SvniCH S�� THERMnL ovER�OnD S�xiai 0 Rrs ANDTRElA07E TEST 3�710N OlE iNDICATOR UCfiT FSD pDFlRE�s d(E DAAIFERM DEMCE CONTROLLING D. �ERNA DEVI ESOTOR STARTERS FOR 31NGLE PHASE MOTORS WHERE INTERLOCKED WITH � KEr OPERAiID SYATCH �� MOMENTMV CONTACT S�xiai E. MANUAL STARTERS SHALL HAYE THERMAL OYERLOAD PROTECTION AND PILOT LIOHT. F. LOCALLY MOUNTED STARTERS SHALL BE E�UIPPED WITH ENCLOSURES DEFINED BY NEMA � MANUAL SNITCH, HORSEPOWER RATED �S CAMBINATON SNITd1 AND DUPLEX RECEPTACIE STANDARDS. � DIMMER SYATCH QP PHOTOCELL CON7ROL 0 N E - LI N E D I AG RA M LE G E N D SECTION 78743 � WIRIN6 DEVICES C SMTCH Wti}1 PILOT L1Cf1i • PUSFiBUTTON (NOt aA ernbWa Ibted belew aa uaM m theae erarinqs) A. WALL SWITCHES `PI (PILOT udiT IS 'ON' wHEN SYniCH i5 'ON') � SYMBOL DESCRIPTION SYMBOL DESCRIP110N t . WIRING DEVICES SHALL BE 20 AMP RATED, HOSPITAL GRADE, AND OF SAME ( SvnicH vATH PILOi uCHT LOCniOR MANUFACTURER INSOFAR AS POSSIBLE. "P (CANIINUOUSLY L1diTED HANDLE) TC TIME CLOCK � DISCANNECT SNITCH � purpgO�ftD 'n' 2. 120I277V WALL SWITCHES SHALL BE QUIET 20 AMP RATED, SLOW�MAKE, SLOWCBREAK � OCWPANCY SENSOR WITH TOGGLE HANDLE, AND TOTALLY ENCLOSED. `� DISCANNECT SYATCN, FuSED PM EM-ENERGr METER, PM�POWER MEIER, pA-aeCWT MONI70e 3. TW07POLE, THREEDWAY, FOUR�WAY, PILOT LIGHT AND KEY OPERATED SWITCHES SHALL REFERENCE SYMBOLS BE OF SAME CONSTRUCTION. �� qRCUiT BREAKEft Q vOLTMEiEn iEST SYATCH 4. SWITCH COLOR SHALL BE WHITE UNLESS SPECIFIED OTHERWISE. � DETUL N07e �ffEltENCE Q �aSnNG ro REMAIN 5. EMERGENCY CIRCUIT SWITCHES SHALL BE RED AND INSTALLED SEPARATE FROM NORMAL -Q]F FUSE As AMMETER TEST SWITCH POWER SWITCHES. ,���p1111111111U�� O1 KiicHEN EWiPMENT RE�IItENCE a oaSnNG i0 BE REMOOEO 6. MANUAL STARTERS SHALL BE FLU3H MOUNTING TYPE WITH STAINLE3S STEEL PLATES. ��p���i DO REG'�����iq� �il�-- CRWN� Qv vaiuEmt 7. MOUNTING HEIGHT SHALL BE421NCHES UNLESS SPECIFIED OTHERWISE. ���� Q.P.••"••.,ST ii,.,, UH MECHANICAL EWIPMENT REFERENCE � DOS7ING TO BE RELOCAIED � B. RECEPTACLES �� � �� E ANN�i�'Q�i SiEa DOwN TRANSFORMER, // INDiC�iES KVA OO AMMETER 1 . DEVICES SHALL BE 20 AMP RATED, HOSPITAL GRADE IN PATIENT CARE AREAS AS DEFINED : v' ' ' � E70STINC TO REIAAIN - RFPLACE DEViCE IN NEC 577-3, INCLUDING PATIENT EXAM, SLEEPING, PROCEDURE, DIF,GNOSTIC, AND = VO:Q' � � � c K-RATFD STEP DONN TRANSFORMER nua $EE 1RpNSFORMER SCHEDULE FOR FEEDER 52E � •S T' ' ABBREVIATIONS /M INDICAIES KVA, / INOICAIES K RA11NG O TREATMENT ROOMS. ALSO PROVIDE HOSPITAL ORADE IN CORRIDORS. CONTRACTOR MAY ? jC.� 36245 7c: _ SEE MEpiANICAL EOUIPMENT SCHmULE PROVIDE SPECIFICATION GRADE ELSEWHERE. DEVICES SHALL BE OF THE SAME � . ; �. �� � WRRENT 1RANSFORMER MEC + 'C • FIXt BREacER FEEDER size MANUFACTURER INSOFAR AS POSSIBLE AND BE OF THE GROUNDING TYPE. % �j.1 • ; (Ci r /, AMPERES M�p NOTOR qRW1T PROIECTOR : o,�JqAY 3 1 2oQr � � ��- POTENnAL 1RANSFORMFR w�.zx SEE FEEDER SCHEDULE FOR FEmER 5ZE 2, DEVICE COLOR SHALL BE WHITE UNLESS SPEGFIED OTHERWISE. q < <1 . ABOVE COUNTER, MWN7 HORIZON7ALLY TO CEN7ERIJNE SEE MECHANICAL EWIPMENT SCHEDULE 3. EMERGENCY CIRCUIT DEVICES SHALL BE RED. �'�i� Fs '••....••' C������� AC pF DEV10E +8' ABOVE CWN7ER OR BACK SPLASH MEC `��J SQiVICE ENTRANCE 1RANSFORMER OG ENCINE CENERATOR 4. OVER COUNTER DEVICES SHALL BE MOUNTED VERTICALLY. ���iry���`S�ONIq'11E��O��� AFF ABOVE FINISHEO FLOOR MIN MINIMUM C. PLATE COVERS � UTILItt MEiER � �-- CONTACTOR/RELAY/CAPAqTIXt (AS NOTED) 1 . MATERIALS SHALL BE AS FOLLOWS: AFG �BOVe FlNiSHED GFtnoE MLO A1AIN LUCS ONLY a) SMOOTH METAL: STAINLESS STEEL. [ _ ] EWiPMENT Ea0.osuRE � 1RMISFER SWITCX - ATS�AUTOAIATIC, AITS=MM1NUAL b) CAST METAL: DIE CAST, RIBBED, FLASH REMOVED, PRIMED GREY PRIMER. ANN ANNUNGATIX2 MTS MANU,LL TRMlSFEa Svn7CH c) GASKETS: RESILIENT RUBBER OR CLOSED CELL FOAM URETHANE. �! � SERVICE NEATH6iNEAD GFi GROUND FAULT INIERUPTER d) WEATHERPROOF: IN-USE, CAST METAL, GASKETED. ARF ABOVE RAISED FLOOR rJ(,` NORMALLY CLOSED � ISCA SHIXiT dRWIT WRRENT AVAIUBLE TVSS iRANSIENT VOLTACE SURCE SUPPRFSSER SECTION 78190 � SUPPORTING DEVICES ASSD uR S�MPLING SMOKE DETEC'�O�v NIC N07 IN CONiRACT A. HANGERS, SUPPORTS AND STRAPS SHALL BE CORROSION RESISTANT OR GALVANIZED STEEL. OK a KIRK KEY INTERLOCIC, SUBSCRIPT INDICATES INIERLAp(m CRWP 57 SHUNT iRIP B. 31NOLE CONDUIT RUNS SHALL BE SUPPORTED BY GALVANIZED CONDUIT STRAPS OR RING ATS AUTOMAIIC iRANSFER SINTCH N� NIGFIT LIGHT BOLT TYPE HANOERS. OE a ELECTRICAL INTQ2LOp(, SUBSCRIPT INDICATES INTERLOCKED CROUP )� 7ERMINAliONS �e-LOAD BREAK, NL8�N0 LOAD BREAK C. MULTIPLE CONDUIT RUN3 SHALL BE SUPPORTED BY TRAPEZE IYPE GALVANIZED STEEL BFG BELOW FlNISHED GRADE �.JQ NORMALLY OPEN OM MECMANICAL INTERLOp( --�� ��- pRpw-pu7 pENCE CHANNELS WITH ROD HANGER3. (`, CANDUIT rJTS NOT TO SCALE D. ANCHORING METHOD$ AS FOLLOWS: EO E�ECTRICALLY OPERATED .�� Pu1G-IN DEV�CE 1 . HOLLOW MASONRY: TOGGLE BOLTS OR SPIDER TYPE EXPANSION ANCHOR3. �q7y C�B�E TELEHSION �� ON CENT6t 2. SOLID MASONRY: LEAD EXPANSION ANCHOR3 OR PRESET INSERTS. � 3. METAL SURFACES: MACHINE SCREWS, BOLT3 OR WELDED STUDS, vall CB dRCUIT BREAKER OFCI OMNER FURNIS4m, CONTRACTOR 7NSTALLED 4. WOOD SURFACES; WOOD SCREWS AND/OR NAILS. 5. CONCRETE SURFACES: LEAD EXPANSION OR SELPCDRILLING ANCHORS. CCTV a�D aRCUIT TEIEViSION OFOI ONNER vuRNiSHm, O�ER iNSTALLEO M E D / C A L E Q U 1 P M E N T S C H E D U L E E. RACEWAY3 SHALL BE SUPPORTED EVERY 10 FEET AND WITHIN 38 INCHES OF EACH OUTLET, V al1 ey ELL, FITTINp, PANEL, ETC. �E� IXiSTINC OSWF ON 5TE WIX2K FOFiCE Kev i7EM MoTORS orHER EQUiv, VOLT.4�e FeeoeR PROrec7ionl DISC ,4i UwT N07E F. CONDUIT SHALL NOT BE SUPPORTED OR ATTACHED FROM CEILING SUPPORT WIRE3. EM ���CY pg PULL BO% HP FLA WATTS �� �a) VLTS PH 'SETS SIZE "C BREAKER DISQ SW, FUSE DISG SW, FUSE G. RACEWAY$ OR EOUIPMENT SHALL NOT BE SUSPENDED FROM PIPING OR DUCTWORK. IMi IMAGING NUC. MED. 15.3 3.182� 208 1 1 2 # 10 .1 # 10 G 3l4 30 A 2 P L6�30R EMDC ���CY MAN DIS7RIBUTION CENTER SB STAND-BY Si STERILIZER 1800 1 ,800 120 1 1 2 # ', ? 1 # 12 G 314 20 A 1 P STO SECTION 1819S - ELECTRICALIDENTIFICATION Medical sz s7EaiuzeR � soo i ,eoo �20 � � 2 x � 2 .� � � 2 c aia 20 .c � p s7o A. IDENTIFY 3YSTEM RACEWAYS WITH PAINTED COUPLING3: PROVIDE PAINTED COUPLINGS FOR Ep IXPL090N PROOF SDC SUB-qS11t16UTI0N CENIER S3 S7Eaiuzq7i0N SvsTEM 5oao 5.Oa0 208 3 7 3 a f2 J � 72 G 3/a 2o a 3 P �27 •2o ALL CONCEALED RACEWAYS. INSTALL PAINTED COUPLINGS AT ALL CONDUIT CONNECTING Sa STERIR4D 200 STERILIZER 5ei 70 5s.n0 aBO 3 � 3 z z .� � s G i va ioo A 3 P i oo A 3 P e5 COUPLINGS INCLUDING END COUPLINGS AT STUB OUTS. REVIEW FOLLOWING COLORS WITH EPO ���CVPONEROfF 7P TAMPERPROOF NOies�, OWNER; PROVIDECOLORSPEROWNERSDIRECTION: C/ enter NORMAL POWER: BLACK EVO ���CY VENTIU110N ON/OFF NSS TRANSIENT WLTAGE SURGE SUPPRESSER LIFE SAFETY POWER: YELLOW CRITICAL: OSHA PURPLE EWC E�cmic w�ie2 coo�k Typ nviCU E�UIPMENT BRANCH OR STANOBY SYSTEM RACEWAYS (WHEN SEPARATE BRANCHES ARE FA FlRE AURM �JF UNDER FLOOR UPS: BROWN D): OSHA ORANGE (,` CRWND �J(,` uNDER CROUNO FIREALARM: OSHARED BMS/TEMPERATURE CONTROL: DARK BLUE GCP CENERATOR CONTROL PANEL UON UNLESS OTHQtN15E NOTED M E C H A N I C A L E Q U I P M E N T S C H E D U L E MEDIUM VOLTAGE: ORANGE LABELS GROUND: SAFETY GREEN KEY �� ITEM MOTORS �. OTHER EQUIV. VOLTAGE FEEDER PROTECTION DISCATUNIT �. NOTE DATAANDTELEPHONE3YSTEM: LIGHTBLUE GFI GRWND FAULT IN7EftRUPTINO �f PS UNINTERRUPTABLE POWQ2 SUPPLY HP FLA WATTS �D (VA) VLTS PH SETS SIZE "C BREAKER DIS0. SW. FUSE DISC, SW. FUSE SECURITY; WHITE HOA HAND OFF AUTOMATIC V yp�TS EF-7 EXHAUST FAN 1/3 Eu6 120 I 1 2 # 12 . 7 # 12 G 3/4 20 A 1 P I Si0 1 PAGING AND $OUND: GREY SB-1 STEAM BOILER 1 tl3 864 208 3 ' 1 3 # 12 ,1 # 12 G 314 20 A 3 P 30 A 3 P 3.8 1 NURSE CALL SYSTEM: PINK IG ISOLAIED CRWND �p VARIABLE FREWENCY DRIVE NOTES�. � . eawaMeNi iS NOTeo oN eMERGeNCV aOWEa. B. COLORED ADHESIVE MARKING TAPE SHALL BE PROVIDED FOR ALL RACEWAYS, WIRES, AND MAX MAXIMUM W� vnrn CABLES. (COLOR TO BE DETERMINED BY ENGINEER IN FIELD). C. VINVL OR VINYL�CLOTH, SELFDADHESIVE, WRAPAROUND, CABLEICONDUCTOR MARKERS F i rs t F I o o r MCB MAIN dRCUIT BREAKER yy�0 �T�'�WT SHALL BE PROVIDED FOR WIRE/CABLE DESIGNATION. 40NR CANIROL CENTER NEAINER PROOF D. ENGR4VING STOCK MELAMINE PLASTIC LAMINATE, WITH ENGRAVED LEGEND IN WHITE MCC WP � LETTERS ON BL4CK FACE AND PUNCHED FOR MECHANICAL FASTENERS SHALL BE PROVIDED N u c I e a r M e d i c i n e MDC �aN DISTRIBUTION CFNTER XFMR �ANSFORMFR FOR PANELBOARDS, SWITCHBOARDS, DISCONNECTS, ETC. E. FUNGUS�INERT, SELFnEXTINGUI3HING, ONEIPIECE, SELFOLOCKING NYLON CABLE TIE3, SUITABLE FOR A TEMPERATURE RANGE FROM MINUS 50 DEGREES F TO 350 DEGREES F SHALL S P C R e m o d e I L U M I N A I R E S C H E D U L E BE PROVIDED WHERE CABLES ARE BUNDLED, PROVIDE TIES IN SPECIFIED COLORS WHEN USED FOR COLOR CODING. NURSE CALL LEGEND TYPE DESCRIPTION LAMPS VOLTAMPS MANUFACTURER CATALOGNO. VOLTAGE FINISH MOUNTING RECESS �I 6" COMPACT FLUORESCENT DOWNLIGHL CLEAR ALZAK 1 -26W DTT PORTFOLIO C6126-E-6250 N SECTION 18452 C7 6ROUNDIN6 (NOt a�� a„neds �'istee edow are uxd on thae dra�inga) pF5 n�r ��� i :.�, ..i �i � � . ���.,>� ��uu� . �� � - � - --' ' :. - --' - -- � _ �, �; � � � -- -- - --^ -• A. GROUNDING CONDUCTORS SHALL BE COPPER IN ALL CA3ES. �� � � �..�.�.. . . . . „ --- . . .:.__ . . SYMBOL DESCRIPTION SYMBOL DESCRIPTION e2cai o-TRW � � C. GROUNDITHE S CONDARY EL C�RICAL S STEM AND COMMUNICATION SYSTEM IN � 2'X4' RECESSED DIRECLINDIREC7 .3-F0321835/ECO O1 -F 9NGLE PATIENT STATON PBOE -F EAIERCENCY STATON PC�PULL CORD, PB�PUSNBUTTON RG2432 WITH CENTER PERF, 2 BALLAST 100 METALUX 2RDI-232RP�120V-ER92 120 WHITE RECESS 6" ACCORDANCE WITH THE NEC. ///��� ''' //�� '' �Rio SECTION76470 • PANELBOARD8 181 W . Meadow Drive � DOUBLE PATIENT STATION � DOME LIGfiT, WALL MWNTED TG2432W I Z'X4' LE WET LOCATION 2LBALLAST DOORS. 3-F032I6351EC0 ' 00 METALUX I 2G�CBFA-323-120V-ER82 120 WHITE RECESS A. ALL PANELBOARDS ARE EXISTING TO REMAIN. 3�3ia" B. PROVIDE NEW CIRCUIT BREAKERS TO MATCH EXISTING WHERE INDICATED. CIRCUIT Va i I Co I o rad o S si� sunav DOIAE L1GH7, CERING MOUN7ED cRio BREAKER3 SHALL BE THERMAL�MA6NETIC, QUICK�MAKE, QUICKOBREAK, TRIP FREE, TRIP � OD -F Dutt S7�nON OC -F ELAPSE TME CLOCK � 'Xa' suRFa.ce iROFFeRS 2-FO3zis35iEC0 � '� INDICATING, BOLT�IN TYPE WITH AND RATED FOR THE AVAILABLE FAULT CURRENT. � � C � � TSia2 �. wiiht EXTRU�eo .4CRVLiC ReFRa.CTOR 6e ME7A�UX SA�232A-120V-ERBt i2o WHiTe � SuRF.4eE C. PROVIDE NEW PANEL DIRECTORIES FORALL EXISTING PANELBOARDS WHERE NEW WORK V TWO BALLAST � OM -} MAS7ER STA110N �� -F TIME CLOCK RDAOTE CONIROL 1 'X4' STRIP LIGHT VAPOR-TITE, 3-F0321835/ECO . OCCURS. °e CODE BLUE STAlION POS -F PRESENCE STATION TS143W REIFORCED FIBERGLASS MOUSING 100 METALUX � VT2-332DR-120V-ER81 � 120 WHITE �, SURFACE � -- $ECTION 7E475 • OVERCURRENT PROTECTIVE DEVICES coNnNOUS ao�vuaEiH.qNe cASKETwc A. CIRCUIT BREAKERS SHALL BE OF THE SAME MANUFACTURERAS PANELBOARD; THERMAL NCAP NURSE CALL ANNUNdATOft PANEL NCPP NURSE CALL POWIIt PANEL 4' UNDERCABINET LIGHT 1 -F032 MAGNETIC, DUICKCMAKE, QUICKOBREAK, TRIP FREE, TRIP INDICATING, BOLT�IN TYPE AND UC4 LINEAR RIBBED ACRYLIC DIFFUSER 34 METALUX CL-132-120V-ER81 120 WHITE SURFACE -- RATED FORTHEAVAILABLE FAUL7 CURRENT. ' � � ' B. WHERE NOT A PAR7 OF A PRE-FABRICATED PANELBOARD, CIRCUIT BREAKERS 5HALL BE , uNiveRS.a� MouNr �ED exiT uGHT. SiNC�e FACE, wr�iiE sUaEUTE Lpx-eo-ewH INSTALLED IN A NEMA 1 OR NEMA 3R ENCLOSURE AS REpUIRED. x� FACE, GREEN LETTERS LEDS INCLUDED 1 ,8 LITHONIA 277 WHITE UNiVERSAL C. DISCONNECTING SWITCHES SHALL BE NEMA 3TANDARD TYPE "HD' 100 PERCENT DUTY RATED � IN NEMA 1 ENCLOSURES WITH �UICKGMAKE, �UICKGBREAK OPERATING MECHANISMS. eeNERA� No7es � PROVIDE FACILITIES FOR PADLOCKING IN "OFF' °OSITION. 1 . CATALOG NUMBER REFERS TO FIRST NAME LISTEO UNDER MANUFACTURER 3. /+�� �enlSES us7eo As , � 25" MiNiMUm SH/+�� sE e,� ozisq a. D. NEMA 3R ENCLOSURES SHALL BE USED IN FJCTERIOR OR WET LOCATIONS. E LE CTR I CAL PER LUMINAIRE TYPE. REPdAINING MANUFACTURERS LISTED ARE CONSIDERED EDUIVALENT PRODUCTS FOR THIS PROJECT AND SHALL MEET ALL CRITERIA 4 , PROVIDE QUANTITY OF BALLASTS FOR INDIVIDUAL LJMINAIRES AS RE�UIRED TO L E G E N D S AN D LISTED INCLUDING THAT CALLED FOR BV TNE SPECIFIC LUMINAIRE CATALOG ACCOMMODATE SWITCHING ARRANGEMENTS AS SHOWN ON THE DRAWINGS. NUMBER. CATALOG NUMBERS �O NOi NECESSARILV REPftESENT COMPLETE CATALOG NUMBERS. ALL ITEMS LISTED IN THE DESCRIPTION SHALL BE PROVIDED. 5. ALL DIMMER BALLASTS SHALL BE LUTRON. S C H E D U LE S 2. ALL LIGHTING REQUIRING A BALLAST SHALL BE PROVIDED WITH AN ELECTRONIC fi. ALL FLUORESCENT BALLAST SHALL BE PROGRAMMED R4PID START. HIGH POWER fACTOR BALLAST WITH LESS TMAN 10% THD. DATE 2 APRIL 2007 DRAWN BY CHK'D BY KRB SHEET FILE P - ELSD COPYRI6HT 2005 BY DAVIS PARTNERSHIP P.C., MCHfTECTS SHEET NUMBER: E1 . 01 Cator, Ruma & Assoa FILENAME, P�. \VVMC 2006- 367 NUCLEAR MEDICINE REMODEL CAD ELEC P- ELS. DWG _ E1 .01 PLOT�. OS 31 2007 � 11 : 20am REV: OS 31 2007 CAD�. KBathke XREF: tb. dwg SPEC.dwg ONE- LINE DIAGRAM NOTES : 1 . PANELBOARDS INDICAlED ON ONE LINE DIAGRAMS DO NOT SHOW ALL BRANCH CIRCUITS. REFER TO PANELBOARD SCHEDULE(S). 2 . EQUIPMENT SHOWN SHADED REPRESENTS STAND-BY POWERED SERVICES. 3 . PROVIDE CONi1NU0US �10 INSULAlED COPPER CONDUCTOR FOR BONDING THE I EQUIPMENT GROUNDING iERMINAL BUSSES OF iHE NORMAL AND ESSENIIAL BRANCH CIRCUIT PANELBOARDS SERVING 7HE SAME INDIVIDUAL PA7IENT VICINITY. � � � � Archit l.S � DETAIL NOTES THIS SHEET : O PRICE SEPARAIELY AS ADD ALiERNA7E N0. 1 : PROVIDE iHREE PHASE DIGITAL RECORDING CIRCUIT ANALYZER (DRANETZ 808, BMI 3030 OR EQUAL) ON INDICATED PANEL FEEDERS FOR A PERIOD OF THIRTY DAYS PRIOR TO THE START OF CONSiTiUCT10N TO VERIFY EXISTING LOAD. CIRCUIT ANALYZER SHALL RECORD p301 BLAKE ST. , STE. #100 VOLTAGE, AMPERAGE, KVA AND POWER FACTOR FOR EACH PHASE AND AVERAGE DENVER , COLORADO 80205 FOR ALL PHASES. ANALYZER SHALL ALSO RECORD A PER DAY MAXIMUM DEMAND. 303.861 .8555 F.303.861 .3027 THE CONTRACTOR SHALL COMPILE A SUMMARY REPORT LISTING MAXIMUM READINGS AND SUBMIT THE REPORT AND TAPE TO THE ENCINEER. ANALYZER SHALL HAVE BEEN CAL16RAiED IN PREVIOUS 60 DAYS. SUBMIT DOCUMENTA110N OF CALIBRA110N 0225 MAIN STREET . UNIT C101 ALONG WI1H LOAD TAPES TO ENGINEER. RE: FLOOR PLANS FOR ADDI110NAL EDWARDS, COLORADO 81632 INFORMAiION. 970.926.8960 F.970.926.8961 LOAD SUMMARY "LA " EXISTING LOAD REMOVED LIGHTING -1800.00 VA NEW LOAD ADDED LIGHTING 7062VA X 125 1328.00 VA TO AUTOMATiC TRANSFER NET LOAD REDUCTION -472.00 VA SWITCHES #1 ,2,3 � LOAD SUMMARY "LPA " X-RAY EXISTINGPEAKDEMAND "TBD" KVA RM. 2 I 30 DAY METERING q 1 q t !� c f AC NUCLEAR ' NECDEMANDFACTOR z125% C!\ I � � R, RII ��Ii`� U �'I .JSOCIATI '.�, CO. NUCLEAR MED , MED.� NEC CORRECTED PEAK DEMANDLOAD "TBD" KVA CO.\'SfIITI\'Ci �7f:C71A\'I( 'AI.rGLP.CTRICAI. f:N( �IKGGRS HUMIDIFIER AC-2 AC-4 AHU- 2 X-RAY RAF -2 ��TB��� AmPs +. 550 Dover Street . S�ite Two . Lakewood. CO 60215�3132 303I2328200 . Faz 303I2333701 EXISTING LOAD REMOVED r.ra@fatnrtwna ccm . www caWrrm•ia com RECEPTACLES (9) -1620,0 VA SUBTOTAL LOAD REMOVED -1620,0 VA 40.3 40.3 30.3 20.3 NEWLOADADDED ISSUE/REVISION DATE NO. LIGHTING (68W X 1 .25) 85.0 VA A RECEPTACLES (8) � aao,ova. TOVCOMMENTS 06-01 -07 1Q 40. 4G 150.2G 90.4G 150.3 175,4G 175.4 � 350.3 � � �EMPTY � �EMPTY � _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ S3SUBTOITALLOADADDED 6565.OVA I � _ _ _ � � NEW TOTAL PANEL LOAD 4945.0 VA 1 SPARE 40A 40A 30A � � 7A 5A 40A t00A 60FRN 100A 150A 175A 175A 300A i i 60A3P 60A3P 60A3P 60A3P 30A3P 30A3P 30A3P 30A3P i 60A3P 100A3P 100A3P 700A3P 200A3P 200A3P 200A3P 400A3P 1 2 J 4 5 6 7 8 I 1 2 3 5 7 9 11 13 - - - - - - - - - - - - - - - - - - J � - - - - - - - - - - - - - - - - - - - - - - - - - -I- - � LOADSUMMARY "LPL �� "MCC (SQUARE D QMB - SAFELEX) "MDP" 208V, 30, 3W 120/208V, 30, 4W EXISTING LOAD REMOVED 200A 1000A CLINIC CLINIC EXISTING NUC MED EQUIPMENT -4600.00 VA ORIGINAL PULLBOX LPD LPC NEW LOADADDED NEW NUC MED EQUIPMENT 3200.00 VA NET LOAD REDUCTION -1400,00 VA BSMT. BSMT, P2 ELEC, RM. ELEC. RM. - � - � 1 AMBULANCE BUILDING LOAD SUMMARY °PP•1 ° FEEDERS AHU i I i � \������ p0 REG ��ii�� UNIT MECH. EQ, EXISTINGPEAKDEMAND "TBD" KVA �� QP1`11•I•I•f�"//'�S �G COND'F7E/SING �ON ROOF� ELEC. DIST PNL iTEA3P 100A3P 30DAYMETERING �\����•EAN��•��(C �'�, 200A3P�200A FUSES ROOM O ROOM (ELEC. RM. � - - NECDEMANDFACTOR x125o�0 ,� O� B ��� � NEC CORRECTED PEAK DEMAND LOAD "TBD" KVA �, �= C�i C =, 100A3P 100A FUSES 480-120/208- 3 ��7BD• Amps _ • m: _ 36245 �. � 480- 120 208V- PG- PGBHIA PGDHM P1 P3 PHAR- • V _ LIEBERT BL1A1 M M MACY J O A Y 3 1 1 0 • RF xFMR CT 0- 4W 500KVA . , � 30- 4W 75KVA ROOM SCANNER PANEL "LA" LOAD 472.00VA ' � �. • • � INTERCEPTOR EXISTING LOAD REMOVED % ni• <(/ � W WP TRANSFORMER ' • • . a� � TRANSFORMER CIRCUIT ���� - � ,(�� �y- � � BREAKER I �„ I TVSS F ± NEW LOADADDED /�� �i����� �NAL E \����• \\ 4#250 MCM, 1 �4G- 3"C. i � i � q,, SS� NG ..�` W/SHUNT i- 200A3P 125FRS ISCA=38A77 i ����I ' 1`��� I I � XFMR XFMR ' � I ' n � _ _ � i '�� PANEL "LPA" 4945,00 VA y ` J ' I XFMR � �' ^ j METERS AND i NEW TOTAL PANEL LOAD 4473.00 VA � � GROUND TO BUILDING I \ � CABINETS STEEL AND COLD � '? � - - WATER PIPES T T � N - = Ci • 'N 3O 4S � 'U � T � � LOAD SUMMARY "DLA " HOLY CROSS � 75 � w OLY CROSS 500K A M METERING a o Q EXISTING PEAK DEMAND "TBD" KVA 277�480V- 30 ^ � � 30 DAY METERING SECONDARY PAD a XFMR XFMR 200.4G XFMR 1200.4G 800.3G � � 200.4G 600.4G 1000.4G 400.4G NEC DEMAND FACTOR z 125°/ MOUNT KFMR ISCA= 19, 783 � v NECCORRECTEDPEAKDEMANDLOAD "TBD" KVA T _ - _ _ T _ _ _ - _ _ - _ _ - _ _ - _ _ - _ - _ _ � _ _ � � _ _ T _ _ _ "TBD" AmPs � _ _ _ - _ _ - _ _ � I I � � I SPARE � EXISTING LOAD REMOVED a�l I 150LP5 60A 45A 70A I SPARE 200A 110A 125LPS I 1200LPS 750A � 600KTN 200KTN EDOKTN 1000KTN 400KTN I LOAD PANEL "LA" 472.00 VA PR'"°`E Valley ISCA= 43, 100 i 3000A3P GFCI � 200A3P 60A3P 100A3P 100A3P 100A3P 200A3P 200A3P 200A3P 1200A3P 12DOA3P I I I 600A3P 400A3P 600A3P 1200A3P 400A3P NEW LOAD ADDED EXISTING HOLY CROSS LOAD PANEL "LPA" 4945.00 VA PRIMARY SYSTEM i V7E3622 V7E3633 V7F3604 � HCP PRINGLE BOLTSW. BOLTSW. 80LTSW. BOLTSW. BOLTSW. � I 2000A � _ _ _ _ _ _ _ � T325-W01 2 T325- WO7 3 T325- WOl 4 T325- WOl 5 T325-WOl NEW TOTAL PANEL LOAD 4473.00 VA � L- - - - - - - - - - - - - - - - - - ISCA= 40, 937 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -/� DISTRIBUTION PANEL "DHA" PULLBOX "DLA" (WEYCO o ed � cal 120/208V-30+- 4W - - 4/0 GND TO COLD WATER PIPE 4 V- 4-4W 3000A o Center AND MADE ELEC?RODES 3000A, 100, 000 ATE 100,000 AIC � WEATHERPROOF ENCLOSURE 6(4�500 MCM,1q1 �OG- 4"C. ) SERVICE ENTRANCE RATED WI1H (2) SPARE 4"C. 500 KCMIL GROUND TO MDC SECOND FLOOR SECOND FLOOR QMED, RECORDS CORRIDOR (OLD LAB) ISCA= 9,324 � KP-1 LA PB LPA PA LD LPL L1A L1A1 F F i rst F loor HUMIDIFIER CONDENSER 3o.3c x-RAY ELEV. � H- 1 C- 1 RM� 2 EL- PG M � Nuclear Medicine BSML BSMT. F ELEC. RM. ELEC. RM . � � � � S PC Remodel I Oviibr � � �Il�iv / 100A3P I / 100A3P � � 181 W . Meadow Drive � i 200CRNR i50CRNR iSDCRNR 100CRNR 100CRNR 70FRN 70FRN \ / 200A3P 200A3P 200A3P 100A3G 100A3P 100A3P 100A3P �/ � � I , Colorado � 1 � __ �S�A- , 5,98, 81657 1 2 3 4 5 6 7 8 9 � - - - - - - - - - - - - - - - - - - - - "PP- 1 " (SQUARE D QMB) IN BSML ELEC. RM. O Q 120/208V, 3�, 4W 600A FIRST FLOOR FIRST FLOOR . �EA N,N� �EARN, N� PARTIAL FIRST FLOOR CE TER CENTER LIGHTING AND � B��AB�H P�B�, A P�B�, AA SECOND FLOOR KEY PLAN POWER & SYSTEMS PLANS � i I DATE 2 APRIL 2007 i i o ac DRAWN BY CHK'D BY KRB BASEMENT BASEMENT SHEEf FILE P- 1 LINE PARTIAL ONE - LINE DIAGRAM - EAST - NORMAL POWER COPYRIGMf 2005 BY DAVIS PARTNERSHIP P.C., ARCMRECTS SCALE: NONE S4iEEf NUMBER: E3 . 04 FIRST FLOOR KEY PLAN Cator, Ruma & Assoa FILENAME: P; VVMC\2006- 367 NUCLEAR MEDICINE REMODEL CAD ELEC P-1LINE. DWG _ E3.04 PLOT: 05 31 2007 � 11 : 20am REV�, O5/31 2007 CAD: KBathke XREF�, tb.dwg keyplan .dwG 11ine.DWG keyplan2. dwg ONE- LINE DIAGRAM NOTES : 1 . PANELBOARDS INDICAiED ON ONE L1NE DIAGRAMS DO NOT SHOW ALL BRANCH CIRCUITS. REFER TO PANELBOARD SCHEDULE(S). 2 . E�UIPMENT SHOWN SHADED REPRESENTS STAND-BY POWERED SERVICES. 3 . PROVIDE CONi1NU0US �10 INSULATED COPPER CONDUCTOR FOR BONDING 1HE ' . EQUIPMENT GROUNDING TERMINAL BUSSES OF THE NORMAL AND ESSENTIAL BRANCH CIRCUIT PANELBOARDS SERViNG THE SAME INDIVIDUAL PAi1ENT VICINIIY. � � � � Archit l.S DETAIL NOTES THIS SHEET : Q1 PROVIDE THREE PHASE DIGITAL RECORDING CIRCUIT ANALYZER (DRANETZ 808, BMI 3030 OR E�UAL) ON INDICATED PANEL FEEDERS FOR A PERIOD OF 1}iIRTY DAYS PRIOR TO 7HE START OF CONSTRUCTION TO VERIFY EXISIING LOAD. CIRCUIT ANALYZER SHALL RECORD VOLTAGE, AMPERAGE, KVA AND POWER FACTOR FOR 2301 BLAKE ST. , STE. #100 EACH PHASE AND AVERAGE FOR ALL PHASES. ANALYZER SHALL ALSO RECORD A DENVER, COLORAD080205 PER DAY MAXIMUM DEMAND. iHE CONTRACTOR SHALL COMPILE A SUMMARY 303.861 .8555 F.303.861 .3027 REPORT LISTING MAXIMUM READINGS AND SUBMIT 7HE REPORT AND TAPE TO THE ENGINEER. ANALYZER SHALL HAVE BEEN CALJBRATED IN PREVIOUS 60 DAYS. 0225 MAIN STREET . UNIT C101 SUBMIT DOCUMENTAi10N OF CALIBRATION ALONG W1TH LOAD TAPES TO ENGINEER. EDWARDS , COLORADO 81632 970.926.8960 F.970.926.8961 LOAD SUMMARY "EMCC„ NEWLOADONPANELADDED Cf\TUR, R�. I �� I :'� (T A ��� ��C I .� I I'S, CO. PANEL "EM1CA" 1346.00 VA ( '.U15UI:1'I\G \11iC11;1NI( 'AI 'lll li( �'I�RI(�AI . l�\GINPIiR.S PANEL "EM1B" 4464.00 VA 1550 Dover Street � Suite Tw� � Lakewootl. CO 80215�3132 TOTAL NEW PANEL LOAD 5810,00 VA 307i232�6200 . Fax 3031233-3701 cra@c2:orruma.ccn�i . www.catorrur�e con�i ISSUEIREVISION DATE NO. LOAD SUMMARY "EC18" TOV COMMENTS 06-01 -07 Q 4 4, SG THHN- 1 "C. 4 4, SG THHN - 1 "C. EXISTINGLOADREMOVED N N N N NUCLEAR MEDICAL REMODEL PROJECT LIFE SAFETY NURSES STATION RECEPTACLE AT NUC MED �720.00 VA RECEPTACLE AT NUC MED �720.00 VA PANEL LIGHTS SPQ SOTRAGE -1000.00 VA ��� E1 ! � Q EMiB EC1C � EC1A EC1B � ORA ORB� ' uGHTSNUCMEO -� 000.00vn . , 1ST FLOOR RENOVATION PROJECT . . COPIERS (2j AT SHF -2000.00 VA � � � DISHWASHER AT SHF -1000.00 VA BASEMENT BASEMENT OPERATING OPERATING RECEPTACLEATSHF -i80.00VA STORAGE STORAGE ROOM ROOM SUBTOTAL LOAD REMOVED -6620.00 VA 175, 4G 175.4G NEW LOAD ADDED NUCLEAR MEDICAL REMODELPROJECT LIGHTING X 1 .25 1420.00 VA RECEPTACLE 1080.00 VA GENERAl. 1000.00 VA 1 ST FLOOR RENOVATION PROJECT 40, 4G 175, 4G ABG RECEPTACLES 630.00 VA SUBTOTAL LOAD ADDED 4130.00 NET LOAD REDUCTION -2490.00 VA `�����\\Q \`f��oiO •AN��sT�;�i�� II : p":' 6�'.'P �'� I MAX DEMAND _ ��;_�����' �m' � s ze arnas i � �;U 36245 �� _ ATS MAX DEMAND �� �� � � : �C/�$ z� d F�oe� � ' Hz sa aMas 3so.3 LOAD SUMMARY EM1B ���o,�Y 3 1 2007,\�t�,; 40A L�FE SAPETY BRANCH I :, ss,�•.•..•• NC9 .p�'` eoi��R RooM , p � aoAaP r nrs '',i�„ �NAL E �o" � � � � LI �E SAFc Y I � �3 'I EXISTING LOAD REMOVED ������/lllllllll�����\` �'� EN� �� 22�A CRI-'� CP � BRANC�1 �' 0.00 VA � � '. I 200A3�' �-!� ATS � ' � '� . � � JCR��. iICAL � I �� NEWLOADADDED i 400A EQUi?MENT BRANCri ' � I S1 -STERILIZERSVSTEM i800.00VA SPARE BASEMENT � I �� L- @J COND. UNIT AHU- 4 2nd FLOOR I I � 52-STERILIZER SYSTEM 1800.00 VA DISCONNcCT BOILER 50.4G � EXHAUST FAN- NUC MED 864.00 VA SWITCH ROOM (ON ROOF) M BSMT, ELECTRICAL ROOM I 400A3F MAX DEMAND EQUIPMENT 105 AMPS TOTAL NEW PANEL LOAD 4464.00 VA OFF EM1A ELB-EQ O M .� EMiC � 200FRN i � ' i � � I COMPU?ER DUPLEX i I200ASP � DATA RM . VACUUM qHU- 3 P- 1 P- 2 AHU -5 EF- 20 P- 4 AHU- 1 � ' � _ PUMPS � � '� � T Vail � � � I 10b.4 40.4G 30. 3 20.3 30, 3 30.3 30.3 20.3 20.3 20.3 30.3 100.4G 175.4G 40.4G 350.3 Valle � _ _ _ _ _ _ _ _ � _ _ _ _ _ - - _ .� _ - _ _ _ _ _ _ _ _ �_ - _ _ _ _ _ _ _ _ - _ y ; ; T � � � ! � � Med � cal � � � � � � � � 2 EA. i � � 100 TR20R � , 40 � 40 , 0 15 � 30 � 25 � 25 � � � � 7 � 15 � 30 � 100 i� � � � 175LPN 40LPN � 300LPN � SPARE j � 100A3P � 30A3P � 60A3P 60A3• 30A3P 30A3P 30A3P .. , 30A3P . 30A3P 30A3P 30A3P 30A3P 100A3P i � ` 200A3P I 60A3P I 400A3P ` 60A3P , C enter � • • ♦ ♦ �� - - 1 - - Z - - �- - 4 - - -5 - 6 - - - 7 - 8 - - - 9 - '0- - - 11 - -� 2 _ �- 13� I� - - - - - - - - - - - � :_ �1 "EMCC (SOUARE D OMB - SAFELEX ) "EDP" (SQUARE D OMB - 120/208V, 30, 4W Oj SAFELEX) 509, tiEUTRAL 120/208V, 30, 4W 700. a 400A 600A GENERATOR 6�N � DiSCONNECT i 600A3P i First Floor G EM �ENERATOR 404G , �� 4� �SO � Nuclear Medicine 150 KW, O. B PF 188 KVA, 520A Z°e- , z°�, 3m.`W SPC Remodel 150A MAX/PH ON TESTING 10/9 /96 181 W . Meadow Drive Vail , Colorado TO MAIN TO MAIN TO MAIN 81657 DISTRIBU iION DISTRIBUTION DISTRIBUTION PANEL "MDP" PANEL "MDP" PANEL "MDP" - PARTIAL FIRST FLOOR SECOND FLOOR KEY PLAN LIGHTING AND POWER & SYSTEMS PLANS DATE 2 APRIL 2007 DRAWN BY PARTIAL ONE- LINE DIAGRAM - EAST - EM �� RGENCY POWER CHK �o BY KRB SCALE: NONE SHEET FILE P- 1 LINE COPYRIGHT 2005 BY DAVIS PARTNERSHIP P.C., MCHITECTS SHEET NUMBER: E3 . 05 FIRST FLOOR KEY PLAN Cator, Ruma & Assoa FILENAME: P: VVMC\2006- 367 NUCLEAR MEDICINE REMODEL CAD ELEC P - 1LINE. DWG _ E3.05 PLOT: OS 31 2007 0 11 ; 20am REV� OS 31 2J07 CAD: KBathke XREF�, tb. dwg keyplon . dwg 111ne.DWG keyplan2. dwg DEMOLITION NOTES : GENERAL NOTES : 1 . UNLESS NOTED OIHERYASE, BOLD IlEMS IXJ DEMOLJ710N PLAN ONLY INDICAlE 1 . NEW WORK INCLUDED IN hIE CONTRACT IS DENO7ED IN BOLD. EXISTING CONDI110NS ' EQUIPMENT, DEVICES, ETC. TO BE REMOVED. TO REMAIN ARE DENOTED LIGHTLY. . 2 . DEMOLITION DRAWINGS MAY NOT SHOW EVERY 17EA1 TO BE DEMOLISHED. CONIF2ACTOR p , pR07ECT S1F2UCTURE AND OWNER EQUIPMENT fROM DAMAGE. IMMEDIATELY REPLACE SHALL NSIT SITE TO DE7ERMINE AND COORDINA7E 1HE EXACT EXTENT OF DEMOLJTION OR REPAIR, TO ORIGINAL CONDITION, DAMAGE CAUSED BY THE CONiRACTOR WHETHER � � } TO FACILITAlE ALL WORK INDICATED BY hiE CON1FtACT DOCUMENTS PRIOR TO EQUIPMENT APPEARS TO BE CURRENTLY IN USE OR NOT, UNLESS WRITTEN • � Archit `S QUOTATION. NO EX1FiAS WILL BE ALLOWED FOR WORK REQUIRED TO ACHIEVE THE END AUTHORRATION FROM THE OWNER INDICATED OTHERNISE. PREPARE LJSTING OF ALL RESULT AS INDICAlED BY THE CONTRACT DOCUMENTS. REWORK EXI511NG TERMINATIONS, EXISIING DAMAGED 11EM5 AND SUBMIT TO OWNER PRIOR TO BEGINNING WORK. CONNECTIONS, CONOUIT, NARING, ETC. TO ACCEPT NEW WORK. MAINTAIN CIRCUIT 7 C , � C CONIINUITY TO E%ISTING CIRCUITS AND DEVICES TO REMAIN OR BE RELOCATED. PRIOR 3 . INSTALL CONDUIT CONCEALED IN FlNISHED AREAS UNLESS OTHERWISE NOTED. PAINT C L TO COMMENCEMENT OF ANY DEMO WORK, CONFlRM EXISIING CONDITIONS AND NOTIfY EXPOSED CONDUIT TO MATCH EXIS7ING FlNISHES NATHIN 7HE SURROUNDING AREA. ENGINEER OF ANY DISCREPANCIES FOR RESOLU110N. 3 . ALL IiEMS IDENIIFlED TO BE REMOVED SHALL BE REMOVED IN h1EIR EN11REiY 4 . DO NOT ROUTE CONDUIT WIIHIN STRUCTURAL OR TOPPING SLABS OF FLOORS UNLESS INCLUDING ALL 1MRING AND EXPOSED CONDUIT AND CONDUIT SUPPORT$ BACK TO POINT SPECIFlCALLY NOTED OIHERNISE AND WRITIEN APPROVAL IS OBTAINED FROA1 1HE OF ORIGIN OR NEXT DENCE TO REMAIN. REMOVED 17EMS SHALL BE 7URNED OVER TO STRUCTURAL ENGINEER. 2301 BLAKE ST. , STE. #100 �-ii 1HE OWNER, UNLESS NOTED OTHERYASE, AND STORED IN THE AREA DESIGNATED BY 1HE 5 . FlRE SEAL ALL FIRE RAiED WALL AND FLOOR PENEIRAT10N5. REFER TO DENVER, COLORADO 80205 , OWNER. REMOVE FROM SITE AND LEGALLY DISPOSE OF ALL ITEMS THE OWNER CHOOSES ARCHIlECTURAL DRAWINGS FOR FIRE RAiED WALLS. 303.861 .8555 F.303.661 .3027 NOT TO ACCEPT. f� t � -- - -- 6 . COORDINAiE EXACT REQUIREMENTS AND LOCAl10NS OF MECHANICAL EQUIPMENT WIiH 0225 MAIN STREET . UNIT C101 � \ 4 . WHERE EXISTING CONDUITS ARE SHOWN TO BE REMOVED AND HAVE BEEN ROUiED IN EDWARDS, COLORADO 81632 � �� I � I � ' � CONCREiE FLOOR SLABS, CONCRETE WALLS OR CONCREiE CEILINGS, THEY SHALL BE MECHANICAL DRAWINGS AND MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN AND 970.926.8960 F.970.926.8961 � -� �I CUT BACK RUSH WI1H CONCRElE. FlLL `M1H GROUT TO ACHIEVE A SMOOiH AND EVEN ORDERING MATERIA�S OR EQUIPMENT. MEC -i . I� I I MEC -i . I� 'i FINISH RUSH N1TH CONCRETE SURFACE AFTER CONDUCTORS HAVE BEEN REMOVED. 7 . EXISi1NG INFORMATION SHOWN ON THE DRAWINGS HAS BEEN TAKEN FROM OWNER ��i (n � � ' � F❑ I II I FURNISHED DRAWINGS AND/OR LIMIlED FIELD OBSERVATIONS. CATOR, RUMA dc M I I M , 5 . REUSE OF EXISTING CONDUIT IS ALLOWED WHERE CURRENT NEC AND LOCAL CODE ASSOCIAlES IS NOT RESPONSIBLE FOR hiE ACCURACY OF ANY INFORMATION OR 1HE i � REQUIREMENTS ARE MAINTAINED. PROVIDE NEW CONDUIT AND WIRE FOR NEW ADEQUACY SAFET! AND CONFORMANCE TO CURRENT PREVAILING CODES OF ANY �_� �'I !, i I INSTALLATIONS AND E%lENSION OF EXISTING INSTALLATIONS. REUSE EXISTING CONDUIT IN WORK SHOWN AS EXIS7ING ON 1HESE DRAINNGS. _ �� PLACE, DO NOT REINSTALL EXISi1NG CONDUIT. PROVIDE LABELING PER SPECIFICA110NS �� I �l FOR REUSED CONDUIT. , ! B . PROVIDE SEPARATE INSULAlED GROUNDING CONDUCTOR IN ALL FEEDER, HOMERUN _ _._ J II �- � .. �� � .. . < i� � � �.�� ;��=� i ��_'� AND BRANCH CIRCUITS. �._. ;_, 6 . RELOCAlED EQUIPMENT AND DEVICES ARE TO BE CLEANED OF ALL FOREIGN MAlERIAL �I 3 REPLACE EQUIPMENT OR DEVICES WHICH ARE DEFECi1VE OR DAMAGED DURING � �-� c s c s / I � / RELOCA110N. I F �F 5 � � �I � � � i5cd ._� 15cd �, __ � 7 • MMERE EXIS7ING DEVICES, SVNTCHES, MOTOR CONNECTIONS, ETC. ARE TO BE REMOVED J � I ' �I �� �' J I � � � , FROM WALLS WHICH ARE REMAINING, WALLS SHALL BE PATCHED TO MATCH ORIGINAL POWER & SYSTEM PLAN NOTES . FINISH. BLANK COVERPLATES OVER EXISTING BOXES ARE NOT ACCEPTABLE, UNLESS OO � , � �� � I�I _ � IiI � !i NOTED OTHERWISE. -- � 1 . MAKE ALL FINAL ELECTRICAL CONNEC110NS TO EOUIPMENT REIXIIRING ELEC7RICAL - - - - ! __ PROVIDE SUP X UNCO I j 8 , PORT OF EXISTING CONDUITS, CABLES AND 80 ES �ERED DURING P= ! I � - - - - - _ :_- pE � ' � � I CONSiRUC110N AND DElERMINED BY OWNER/ARCHITEC? TO BE INSUFFICIENILY CONNEC110N. THIS SHALL INCLUDE BUT NOT BE L1MIlED TO ALL MECHANICAL AND � � ' ' I � .__ . ---I �� . . __ __ � �F � li TURN bINER Ti 0 OWNER I I -- _ _ I 0 I I Aq�H ' I I � �� I SUPPORTED OR NON-CODE COMPLIANT. OTHER EQUIPMENT INCLUDED IN THIS PROJECT. � � � �� I � I�"� � '., ���' ; � I O� � �oc _ �� � - 2 . PROVIDE FUSES SIZED PER EQUIPMENT MANUFACiURER'S REQUIREMENTS. � �� RI Q � �� � � � � �' � ' �� � ��I� I RI F� _ _ _ i I � ', '� I i ' �i i 3 . DISCONNECT SVATCH LOCATIONS ARE SHOWN DIAGRAMMAIICALLY AND SHALL BE -- � � � RI F � �� I Ri F INSTALLED IN ACCESSIBLE LOCATIONS TO SUIT EQUIPMENT AND SPACE. DISCONNECT �? �� 1 _ _ I�� CB -��' �I � a �� �� -- ----- - �� • SWITCHES SHALL BE VATHIN SIGHT OF iHE EQUIPMENT h1EY SERVE AND MOUNTED AT C.ATOR, RLIMA Q ASSC�CI.�TES, CO. " LIGHTING PLAN NOTES � PP � EC1B EC1B"�� F❑ � ❑F � C � i O QF \\�F � ' 6'-3', MAXIMUM, TO TOP OF CABINET. MAINTAIN NEC WORK SPACE RE�UIREMENTS. CONSULTINC, !VSECHANIC.4LiELECi'RIC.'ALEVG1tiEERS ---- ; ; � RI RI ' � iRELOCA7ED R� R� � 1 . REFER TO ARCHITECiURAL ELEVATIONS AND REFLECIED CEILING PLANS FOR EXACT � 550 ooverStreet . SwteTwo . � ekewood, CO eo2te-3� 32 � � PE , S S P� 4 . RECEPTACLES INDICATED TO BE MOUNTED ABOVE COUNIER ARE TO BE MOUN7ED so3ns2•s2o0 . Fax 303/433-3701 MOUNi1NG LOCATIONS OF DEVICES AND LUMINAIRES. - � �, = "" Q F �O � O� O ' O� I - 1�d � VERICALLY 6' ABOVE COUNiER. ❑ F � ��. F cre�carorruma.com . www.carorruma.com �' � � � � � � RI �F � � � y' `� '� I �0'R I RI R OCAIED R� ,os "o�` 2 . COORDINATE LUMINAIRE LOCAiIONS MAl}I MECHANICAL PIPING, DUCTWORK, ETC., TO 5 . PROVIDE 4" SQUARE OU1LET BOX, SINGLE GANG MUO RING AND BLANK SINGLE GANG � ' � � F � PP � �L PE � p �� Q Q � FEC AVOID CONFLICTS. SEE SPECIFICATIONS FOR COORDINA110N REQUIREMENTS. COVER PLATE FOR ALL INDIVIDUAL 7ELEPHONE, DATA, COIABINATION TELE/DATA AND I I' ' _. . S�S - - - -SS - - - - - - - - - - - - - - - - - - - � n _ ❑ e A � � � � - - - - - - m � i -- ' � TELEVISION OUiLETS. [ROUlE 3/4' CONDUIT WITH PULL 1NRE TO 6" ABOVE ACCESSIBLE ISSUE/REVISION DATE NO. � r � �- - �� - RI i ; �•OR2' •ORB" � i ��� ,{�,��� � � I , ' � _ CEILING] (OR) [ PROVIDE 1 'C. FROM INDIVIDUAL 1ELEPHONE, DATA, AND COMBINA710N i� � ti, \ �' � �W � I i �� II I o '�, '��, �� F �� DETAIL NOTES THIS SHEET . lELE/DATA TO NEAREST CORRIDOR CABLE TRAY LOCA110N UNLESS OIHERWISE NOlED} TOVCOMMENTS 06-01 -07 Q , ' � � � � sP- sroaAC � - ' F i ! � i I Ii PROVIDE INSULATED THROAT CONNECTOR ON CONDUIT END. II� „ 0 � �; ' Q , O O ; � � � I Q1 LUMINAIRES IN ROOM NOTED TO BE TWO-LEVEL SWITCHED, INSIDE LAMP(S) � � " � � SWITCHED TOGETHER, OUTSIDE LAMPS SWITCHED TOGE1FiER. 6 . COORDINATE AND VERIFY EXACT MOUNi1NG LOCAi10N5 OF WALL AND FLOOR DEVICES � � � RI � � Q 0 � � E � WITH ARCHI7ECiURAL ELEVATIONS, AND ANY FURNIIURE OR SPECIALTY EQUIPMENT ' S U P P L I E R D R A W I N G S P R I O R T O R O U G H-I N. � �3 � � � � _ _ � F _ . ; � �I ' 4 p I I ! 4 02 RELOCATE EXISi1NG EXIT SIGN, FIRE ALARM DEVICE. MAINTAIN EXISTING EGRESS � r i i CIRCUIT FOR EXIT SIGN. EXTEND EXISTING CONDUIT AND 1NRE AS REQUIRED. O � � L F I � ; � � � 7 . ALL DEVICES FED FROM AN EMERGENCY CIRCUIT SHALL BE RED. � � SP� � � ' Nuc MEO � ', � �I� wo k E i j '� sr ei i ee ' i i Q CONNECT 120V UNDERCABINET LIGHT$ TO THE NEAREST RECEPTACLE. " C� 8 , PROVIDE HOSPITAL GRADE RECEPTACLES IN PATIENT CARE AREAS AS DEFlNED IN NEC � � � � u� W �� j I I o � F ' I ' i � I AREA OF WORK 04 PRONDE NEW RECEP7ACLE AND CONDUCTOR, REUSE EXISi1NG BOX AND CONDUIT. 517-3, INCLUDING ALL PAIIENT EXAM, SLEEPING, PROCEDURE, DIAGNOSTIC AND � � � � � � '�' ,, i i il 1f2EATMENT ROOAIS. , � ' " � � I RECONNECT NEW NORMAL LIGHTING TO EXISi1NG NORMAL LIGHi1NG CIRCUIT, FROM � , scc sroRn c e � � � � I � 9 . N O R E C E P T A C L E S S H A LL B E M O U N I E D B E L O W +1 8' A F F, U N L E S S N O T E D O T H E R V A S E. � � ' H�ROMOLUX�C�///��� �F ' ' II I i __� � I � I � PANEL LA, SERV1NG 7HIS AREA. EXTEND EXISi1NG CONDUIT AND NARE AS RE�UIRED. , \c�\ � O � PROVIDE NEW CONTROL AS INDICAlED. �JI �� �E � _ _ _ _ _ � n pE - - - - � ' ' 10 . REVISE OR PROVIDE NEW PANEL AND CIRCUITING UBELING ON EXISTING CONDUIT - � ` - - „ � ASSOCIATED WITH AREA OF WORK AND NEW JUNC110N BOXES. I -- --,-- O � rr � REFER TO VENDOR PROVIDED SHOP DRAINNGS FOR ADDITIONAL WORK REQUIRED FOR A COMPLETE AND OPERABLE DIAGNOS7IC ROOM. � � , pROVIDE KROY TYPE LABELS INDICATING PANELS AND CIRCUITING ON FRONT OF 6 � O RECEPTACLE AND . R WORK SWITCH COVERPLAiES I E EXISIING SWITCHING IN 1HI5 AREA TO ACCOMMODAIE NEW CONSif2UCT10N. i � 1Q � RELOCAlE RECEPTACLE CURRENiLY SERVING �S4' TO NEW LOCATION ON EAST 12 • PAGING SY51EM DEVICES AND CABLING TO BE PROVIDED BY OWNER'S VENDOR. WALL OF SIERILIZER ROOM. RECONNECT TO EXISTING CIRCUIT "PB-8'; E%lEND SPEAKERS SHALL BE WHIlE. NEW PAGING SYSTEM DEVICES AND CABLING SHALL MATCH �f PARTIAL FIRST FLOOR ELECTRICAL DEMOLITION PLAN OO EXISTING CONDUIT AND CONDUCTORS AS REQUIRED. NO CHANGE TO LOAD ON EXISTING. � PARTIAL FIRST FLOOR FIRE ALARM PLAN PANEL "PB�. 13 . SECURIlY SYSiEM DEVICES AND CABLING TO BE PROVIDED BY ONTIER'S SECURI7Y „_ VENDOR. NEW SECURITY SYS7EM DEVICES AND CABLING SHALL MATCH EXISi1NG. p������������������Up� b SCALE: 1 �8 -1 �-0�� p SCALE: 1 /8��=1 �-0�� Q C NDUCTORS A DACONDUITAASURE�UREDSF RGNEW �LOCA�TION. NDZCONDUIT. A XTEND COORDINATE LOCA110N OF BACKBOXES AND CONDUIT WI1H OWNER'S SECURIiY VENDOR. \\������OQ,P���y��EpA�,C';ST��i��� E 14 . PROVIDE J-HOOK SUPPORTS 4 FT. O.C. SPACING ABOVE ACCESSIBLE CEILING FOR LOW .`�v;Q;+sW'T B �'P�o EXTEND EXISTING CIRCUIT CURREN7LY SERVING SIERILIZER S3 TO NEW LOCA710N. VOLTAGE CABLING. COORDINATE LOCA110N 1MiH OWNER'S VENDORS. _ (� �Qj��/ n; 0 % 7 E PROVIDE NEW RECEPTACLE. PROVIDE EXISIING CIRCUIT INFORMATION TO ENGINEER � � _ AT START OF WORK. PROVIDE SEPARATE PRICING FOR ADD ALiERNATE 1 : PROVIDE , �U 36245 �: CIRCUIT LPA-34,36,38 TO SIERILIZER S3. RE: ONE-LJNE DIAGRAMS AND ���IAY 3 1 ?OOj.' 1���: � � SCHEDULES FOR ADDITIONAL INFORMA710N. � ,�, ,� �� ; � I . ._ _- � � �� I /,//�� �s • �NA� • �G?\\\ .. /�� s/ � \�. - �` „ I- � --- --- -- ---- I I I � I , /��i//�4q1111��1111\\�\��\` ,.. � ii L ___'_ �� . ..... .._ � __ - .. . . ... ... .....- -_-_. . -....... . .. . _. _- _- _ I J i `� .... . _.-, r .� -..._.. .....---- ...... ;�y � �� . .... . . --- I P A -e �'� ` - ��., ', „PA�� , . rM1B ' \ � ', - i � I�il�i EM1B" � . //� � _ I, �� „ . . ^�` �, I "ECiC" "PPi " _.... ..... . ' ti� . .. / � I ^ . � �I � � �. � �� \ g I CCN ? . .� '�' "EC1C' PPi � � I -� ,.EPB" \� '�. CHART LA' -�---..._,...._ � �L .._. I � ----4-i � °EPB"� CHART � '�, ���A�� ��, /�-I � °� RECORDER �� STORAGE � ..-, ' � �� , RECORDER II . ,. c333 �� ---"-- " � � �--- I _ _ � _.... � _ - A M � ... ----- � � �}..-�� -� � TRANSFORMER 2334 MTD. ABOVE � TIME CLOCK � � I � / LTG CONT � - ___ STARTER _. "PG-BL1A" I (� � I � � ----� �-� - A �,�� ' "PG BH1A" K� � ..�� ��. � ,� --- �--- -`-•-- I � -- LPA" u,� i ------°-- � __ i I�,� -� I _- pQ . . - . _. _ � �__ ---- �� i , � � ! � -._ ... . .........._... _ � i� ME� � : ��, -� - � � � � „M���. � ° alley 0 _ . ' C- \ � I�I � "EM1A" � � I _ „LPL" �, i `� I i L- . y ! __ . I I� i i I > _ _ J�� � M i 1 , A�� ed ca � � � i � i � Ii �Ii ..E � _ I � i _ -I � I� � I , ,T' o . � �I �'I I� ..... ... ....... ...-----� I� �, e�i ', ):� �,••�. iI I � I� '�' � Mi PLENUM� �. J I� II . ..._._ .._ I� `��I I � i AIR i � �..{�. �. ' -- ....... . ..... ----�-I � '�4� ^ , _ ,. ... . .- r ❑ 75 KVA � I Center �_ �. �--i � , I I I �� PADMOUNT � I 1 � N� t � ri � � L - C � I I "P - Hi 0 ' - G E A" � I _� r ^ 7 l _� _ � C8 CCO r . � � ENCLOS� D ITE 175 E TRON � / � � I 0 � � � � . . � � �� CIRCUIT R AK R f R VATOR _F-� . . � B E E ELE � � I II i � �. �. � � I . MDC �J I . i i � �� li �� - I _ d il � � iI _ III II ATS Z � rFUSED ISCONNECT � � � L_.J I i � � I � � � o EDP � ��. I I I ��. 1 i I �i � _ SWITCH �I �, TS143W � � � i --..__._. - � ` I I . a ' ' � ---._. - �� I I � �j ¢ . � , �- � I �, i , � 45 KVA ANSFORMER 0 � � � � � J '� r � � , � � ' '�, � � � � � �, �� .; i EMCCt,' / � Z o � MOUNTED �� ABOVE � �� K.J w CAR WA +. . - - I�� � � � I�l , s� �� �I II �oo � i � _'-_' �! ��I ! � I ULLBOX I - � � . , CAR• wAS. � ��, '� � ATS- 3 � - - � , , i�o� i � . �', ,I i i �i . I � I I � � I � �- i � . - � � � , � _ _ � � � rs,a� _ 000_.._ i ; T I _ �-s� i � , „ I --- --- TS142 ATS- 1 BATTERY -- "PG-DHM" �� _ _ � I \, I � �� I �, _ � � -- -- �� u _ I�I ', �' I i �I , � I ' � I � I - --- - - �--- - � First Floor � � . yl _'� .. ^ EC16' � '� �, � EC1B e O � � N "EMiCA" j BMO,2 F M CHARGER �� --- � � CB li, � I � � „ ' II � � O 5 TS142 TS142 � SB EMiCA- 1 ,3,5 M � � �--., 'i Z � 0�5 CL-8 CL-8 O O EMiCA- 7,9,11 � I' • • �-- �_ � � �� '� X� �� �� � o � � ,�� 2 Nuclear Medicine � <s 'o��, R � F�LQL � �� F�C ��� '- 2 M � F _ .._.. ._._ ._..._ NL-30 II � BF C�'� , ° ���� �y , � _ O __ � F EF � � �: �� � - � ' , �z 3zw . ��2�3zW , � . ��� � ' M '�EM, �A_ 8 � � SPC Remodel LOCAlED 2 I � �. � 0 W \ � �-� / I I I � / I � II il�'' i B I I � �. . I i I / � 0 i � ' �C�10 NL-28 II / N�- � B B-8 � � I� �i I '✓ I I '1 -� ,,, I 2 32 . ;RG24 2 i �/' i L-6 ; I � I � -_-- � II / NU1C�� � +7 I � ` O O � SP" 5 �09A E . i, I I Ti 0 � I./ � 9 S4 II � I 5 - - , FUIJP ROOV i i _ � � � I I TG 43 W U J �,- P-24�26�28 F I � I ! r , � b _' I. � - I I - � -- ---- � � 276 BOLER E3,15,A17 ' • G2 32W 5 G q W I --- .. . . . -- .. i �..3 ���^I NL-30 �- _ _._.. � i' \ 4 � � RG2 32 � .,.._7 I 4 2d32 ' PANEL KEY �l CONTROLS F e I I I, � ���' ' � ' 181 W . Meadow Drive ' CLW,O zC5 S2 � INDICAiES PANEL AND CIRCUIT(S), � I ' ---- , \ , sra� � I I i CL - EC1B � � ' EM1CA-1 I � ' I _ �- II Q-15 NL-3 I I �1'�ICAL{ REFER TO PANEL KEY. - � `JI � I � e - I� i ! i I �o C ZB W cM �L-8 { 1 NL = LPA C . EAI� v I r -- V a � l , Colorado CL-10 I I I _ ioa Q-3 s ai:� O I i � a.:- --�-- ' ���� , � V � � ; ,� �� ,_ . �� � � 265� - I � � 81657 � g' AC�CL-18 � �€� � +42" 4 I � i ' ' ., _ _.I ; i-�-; 2 AC,CL-10 ! ILNL�2 I i � TO ' � AC,CL-1 � g I Q 13 PANEL KEY _ , _ � b I A _ . AC�NL-B�L+ 4z0+�42 S1 1 LPA-343 38 � i NL = tPA I � � 3 -.. � CL?8 2 GL- I ' � I �I cd '� - ' AREA OF WORK 'I � � .... SEC?I0� �, - - �-� � _ � _ - � -_ �._ __ , P PG DHM � i IM1 i ' ' ' � I ' � �-� . .. AC AC�CL 10 0 - _ ' � -- " ' --- " " -._- -. ... ---- �� I�� I C256 � //�\�J -- .. " ' ��NL-28 " ' " ' �e�� " ' ---- _ , BL - BL I ��\�-I I ' . l, � IIII n � EM1B I i !, \ , � C�CL-10 I � , I I I ��fPARTIAL SECOND FLOOR ELECTRICAL ROOM PLAN SCALE: 1 a =, -o PARTIAL FIRST FLOOR ��f PARTIAL FIRST FLOOR POWER AND SYSTEMS PLAN p � LIGHTING AND b SCALE: 1 /8��-, �-o�� ��f PARTIAL FIRST FLOOR LIGHTING PLAN p SCALE: 1 /8��=, �-o�� POWER & SYSTEMS PLANS DATE 2 A°RIL 2007 DRAWN BY CHK'D BY KRB SHEET FILE P-ELEC1 . COPYRIGlR 2003 BY DAVIS PARfNERSNIP P.C., MCHITECIS SHEET NUMBER: E4 . 01 FIRST FLOOR KEY PLAN SECOND FLOOR KEY PLAN Cator, Ruma & Assoc. FILENAME: P: VVMC 2006- 367 NUCLEAR MEDICINE REMODEL CAD ELEC P-ELECI .DWG _ E4.01 PLOT: OS 31 2007 � 11 : 20am REV: OS 31 2007 CAD: KBathke XREF: bgi .dwg pwri .dwg Itgi .dwg tb.dwg clgi .dwg fai . dwg pwr2. dwq bg2.dwg keyplan.dwg keyplon2.dwg . � EX/ST/NG PANEL " EM18 " EOUIPMENT BRANCH EX/ST/NG PANEL " EC18 " CRITICAL BRANCH ' Panel Notes: Panel Notes�, 100 A M.L.O. VOLTAGE 120/ 208 V 7 . NEW LOAD ON EXISTING CIRCUIT BREAKER. 225 A M.L.O. VOLTAGE 120/ 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. . PHASE 3 PH 2. EXISTING LOAD REMOVED. PHASE 3 PM 2. EXISTING LOAD REMOVED. WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. WIRE 4 W 3. REPIACE EXISTING GIRCUIT BREAKER WITH NEW CtRCUIT BREAKER AS SHOWN. TVPE : ITE TYPE : SIEMENS • � � Archit �S MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) MTG. : FLUSH 70,000 AMPERE SNORT CIRCUIT RATING (FULLY RATED) BREAKER BREAKER BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENER4L TOTAL AMP ( P CCT PH CCT AMP ! P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NQTE NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TQTAI. AMP / P CCT PH CCT AMP I P TOTAL GENERAL OTHER MQTORS RECEPT LTG DESCRIPTION NOTE SM COMP RM 0 30 / 1 7 A 2 20 / 1 0 LTG HALL BY KITCH PANEL "ECi C" 0 60 / 1 A 2 20 / 1 0 L-PRE OP/RECOV 1 EF-1 864 864 20 ! 1 3 8 4 20 / 1 0 LTG ELEV LOBBY 0 / 3 B 4 20 / 1 0 R-SHF COPIER 4. SQ PHONE CATIPOL 0 20 / 1 5 C 6 20 / 1 0 HEATER ELEV MYDR L " 0 / 3 5 C 8 20 / 1 0 R-SHF COPIER e COMBO BOX AHU 0 15 ! 7 A 8 20 / 1 0 LTG OB HALLWAY R-CARDIO ABG 0 20 ! 1 7 A 8 20 / 1 1136 7136 L- NUC MED,SPC,STE ILR2 MOTOR 0 / 9 B 10 20 I 1 0 HALL FIRE DOORS E T LIGHT R-IT 0 20 / 1 9 B 10 20 / 1 1080 1080 R-NUCMED,WORK,INJ C 2 2301 BLAKE ST. , STE. #100 NURSERY 0 / 3 11 C 12 20 1 1 0 SHOP FAN BT.P AT B. R-RECOVERY (VERIF LOAD) 0 20 / 1 11 C 12 20 / 1 0 R-SHF OFFICE 2 DENVER, COLORADO 80205 0 1 Si -STERILIZER i800 1800 20 / 1 13 A 14 20 / 1 0 GEN RELAY L-NURSE/EXAM 0 20 / 1 13 A 14 20 / 1 0 R-SNF ANNEX 303.861 .8555 F.303.861 ,3027 1 52-STERILIZER 1800 1800 20 I 1 15 H 16 20 / 1 0 OLD FACP (E) VERIFY LOAD 0 20 I 1 15 B 16 20 / 1 500 500 R-NUC MED COMP t , 12 0225 MAIN STREET . UNIT C101 FAW SYS GEN 0 20 / 1 17 C 18 20 / 1 0 DIEMSION I.AB/ MED ECORD R-RECOVERY 0 20 / 1 17 C i8 20 / 1 500 500 R-NUC MED COMP 1 , 1 ,2 e BROILER CONTROL 0 20 / 1 19 A 20 20 I 1 0 BLR RM 2 LTG L-STOR4GE 0 20 / 1 19 A 20 20 / 1 0 R-SH ANNEX EDWARDS, COLORADO 81632 REC- ENDOSCOPV 0 20 / 1 21 B 22 20 / 1 0 TP� OR80B (E) VERIFY LOAD 0 20 I 1 21 B 22 20 / 1 0 SPARE 2 970.926.8960 F .970.926.8961 O GR AUTOMATIC D00 S 0 20 / 1 23 C 24 30 / 1 0 NEW PHONE EQUIP R-LABOR 2 0 20 / 1 23 C 24 20 / 1 0 R-RECOVERY (VERIF LOADO PHASE LOADWG SUMMARY PANEL LOADING SUMMARY R-CRASH CART � 20 ! 1 25 A 26 20 1 1 0 (E) VERIFY LOAD GENERAL NOTES: BREAKER ACCESSORIES R-LABOR 1 0 20 / 1 27 B 28 20 / 1 0 VIEWBOX READING R ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECL • = GFCI R-IT 0 20 / 1 29 C 30 20 / 1 0 R-SHF COMP ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. • • SHUNT TRIP R-IT 0 20 / 1 31 A 32 20 I 1 0 L-LAB 0 2 SPARE 0 20 / 1 33 8 34 20 ! 1 0 SPARE R-CARDIO ABG 0 20 I 1 35 C 36 20 I 1 0 NURSE CALL 0 2 SPARE 0 30 / 37 A 38 20 ! 0 SPARE 2 2 0 / 2 39 B 40 / 2 0 EX/ST/NG PANEL ��EM1 C�� EQUIPMENT BR4NCH R-STURAGE 121 0 20 / 1 41 C 42 20 / 1 0 (E) VERIFY LOAD SINGLE GANG PLASTER RING WITH 0 PHASE LOADING SUMMARY PANEL LOADING SUMMARY GROUND SCREW AND PIGTAIL TO Pane� Notes: GENERALNOTES�. BREAKER ACCESSORIES MATCH DRYWAIl 1HICKNESS M,L.O. VOLTAGE 120/ 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • = GFCI 125 A BUS PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. ' PROVIDE TVPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCiL, ' = SHUNT TRIP WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITN NEW CIRCUIT BREPKER AS SHONM. TYPE : S�UARE D 4. EXISTING LOAD. EXISTING LOAD IS ESTIMATED. Q MTG. ', SURFACE "[ ]" AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED, 6, NEW LOAD. BREAKER BREAKER EX/ST/NG PANEL ��LPA �� NORMAL BR4NCH RECEPTACLE BOX SUPPORT DETAIL NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP ( P CCT PH CCT AMP I P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE 4 PACS Eo, 1000 1000 20 I 1 A 2 20 / 1 800 800 C0. MED COMPUTER 4 Panel Notes 4 1000 1000 / 2 3 B 4 20 / 1 800 800 CO. MED COMPUTER 4 225 A MAIN CIRCUIT BREAKER VOLTAGE 720 I 208 V 1 , NEW LOAD ON EXISTING CIRCUIT BREAKER. r,1� 1 q (` !, NO SCALE SPARE 0 20 / 1 5 C 6 20 / 1 1000 1000 FREE2ER 4 PHASE 3 PH 2. PROVIDENEWCIRCUITBREAKERINSPACETOMATCHEXISTMG. C��TvI�, RU � IrI CI A�SVC � ATI"S, CU. 3 PANEL EMiCA 0 0 MREF! 1000 0 #REF! 50 ! 7 A 8 30 / 2000 2000 EQ. CLOSET 4 WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITM NEW CIRCUIT BREAKER AS SMOWN. CONSl11TIXG MLC}i�N�('r\L�LLf:CTRICAL LNUINLGRS O9-� 4-OB 16135. 3 0 0 #REF! 0 0 NREF! / 9 B 10 / 2 2000 2000 4 TYPE : ITE 4. EXISTING LOAD ON NEW CIRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. 0 0 #REF! 500 0 SREF! I 3 11 C 12 20 � 7 0 SPACE MTG. : FLUSH 10,000 AMPERE SHORT CIRCUIT RATING (FULLV RATED) 5. EXISTING LOAD REMOVED. 1550 Dover Street . Suite Twa . Lakewood, CO 802153132 4 PACS 208V -R4DIOL0 Y 1000 1000 20 I 1 13 A 14 20 / 1 0 SPACE 6. NEW LOAD. 303/232-8200 • Fax 3031233�701 4 PAC5208V -RADIOLO Y 1000 1000 20 11 15 B 16 20 7 1 0 SPACE BREAKER BREAKER cra�catorruma.com . www.catorrumacom SPACE 0 2011 17 C 18 20 / 1 0 SPACE NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP I P CCT PH CCT AMP I P TOTAL GENER4L OTHER MOTORS RECEPT LTG DESCRIPTION NOTE SPACE 0 20 / 7 19 A 20 20 / 1 0 SPACE HEAT PUMP 0 20 / 1 A 2 20 / 1 0 LTG-LAB SPACE 0 20 I 1 21 B 22 20 / 1 0 SPACE 0 / 3 B 4 20 / 1 0 REC-IRADMINOFF. ISSUEIREVISION DATE NO. SPACE 0 20 I 1 23 C 24 20 / 1 0 SPACE -- 0 I 3 5 C 6 20 / 1 0 WIREMOLD-ADMIN O F. SPACE 0 20 1 1 25 A 28 20 � 1 0 SPACE FANCOILUNIT 0 20 i 1 7 A 8 2011 0 REC- IRADMINBBAT TOV COMMENTS O6-O 'I -O7 Q SPACE 0 20 I 1 27 B 28 20 / 1 0 SPACE I-NORTH CORRIDOR 0 20 ! 1 9 8 10 20 / 1 0 REPEXAM RM 29 SPACE 0 20 / 7 29 C 30 20 / 1 0 SPACE SPARE 0 20 / 1 N C 12 20 / 1 0 REC-IRADMINOFF. PHASE LOADING SUMMARY PANEL LOADING SUMMARY LTG-EM RM 0 20 I 7 13 A 14 20 / 1 0 REC-MAMMOGRAPH LOAD TYPE (VA) PH A PH B PM C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND REC-ADMIN OFFICES 0 20 / 1 15 B 16 20 / 1 0 DENTAI X-RAY LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL HEAT CONTROLS 0 20 I 1 17 C iB 20 ! 1 0 DENTAL CHAIRS CONNECTED PF= CONDENSING UNIT 0 20 / 19 A 20 30 / 1 0 EXISTING LOAD LIGHTING 0.0 KVA x 725% = 0.0 KVA x 95% � 0.0 Kw #REF! -- 0 / 2 21 B 22 20 / 1 0 REC-STORAGE LIGHTING 0.0 0.0 0.0 RECEPTACLES DENTAL XRAY 0 20 / 7 23 C 24 20 / 1 0 REC-ULTRASOUND U IT RECEr TACLES 0.0 0.0 0.0 FIRST 10 KVA 0.0 KVA z 100°/ = 0.0 KVA z 100% = 0.0 KW CONNECTED DENTAL XRAV 0 20 / 1 25 A 26 20 / 1 0 REC-ULTRASOUND T IL MOTORS NREFI $REF! #REFI REMAINDER �,0 KVA z 50°!0 � 0.0 KVA z 1�0°!0 = 0.0 KW AMPACITY = LTG-BASEMNT STOR. 0 20 I 1 27 B 28 20 / 1 788 720 68 REC-NUCLEP,R MED 1 ,5 OTHER 7000.0 0.0 500.0 MOTORS f1REP! KITCHEN HEATED 0 20 / 1 29 C 30 20 I 1 720 720 R-SPC,STERILE,NUC E�,5 GENERAL 4600.0 4800.0 0.0 LARGEST NREF! KVA x 125% �IREF! KVA z 90% _ #REF! Kw PLATE DEISPENSER 0 20 / 1 31 A 32 20 / 1 0 PARKING GATE TOTAL NREF! #REF! #REF! REMAINDER #REFI KVA x 100°h =#REF! KVA z 90% _ #REF! Kw NEC DEMAND LTGCOMPACTOR 0 20 / 33 B 34 20 / 1680 1 ,880 S3-STERILIZER 3,5 PHASE BALANCE A-B B•C C-A OTHER 1 .5 KVA t 125% = 1 .9 KVA z 100% = 1 .9 KW AMPAGTY = LTGSIGN 0 / 2 35 C 36 / 1680 1 ,680 5 #REF! $REF! #REF! GENER41 9.6 KVA x 100% = 9.6 KYA x 1��% = 9.6 KW #REF! COMPACTOR 0 2� ! 37 A 38 ! 3 1680 1 ,680 0 / 39 B 40 20 / 1 0 REC-STORAGE REfRI TOTAL #REF! KVA #REF! KVA NREF! Kw 0 / 3 41 C 42 30 / 1 0 LTO- ULTRASOUND M MO GENERAL NOTES: BREAKER ACCESSORIES PHASE LOADING SUMMARY PANEL LOADING SUMMARY ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • • GFCI GENER4L NOTES: BREAKER ACCESSORIES ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ' = SHUNT TRIP ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL, ' = SHUNT TRIP EX/ST/NG PANEL "EM1CA " EQUIPMENTBRANCH ��������������REG� ���o��� �. ... ..., , . . o` o .•N� AN/�i� T6"� Panel Notes: 1 EX/ST/NG PANEL ��LPL �� NORMAL BRANCH . � •� � BO�� � 50 A MAIN CIRCUIT BREAKER VOLTAGE 120/ 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. Panel Notes: � U: �:O % 100 A BUS PHASE 3 PH 2, PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. 225 A MAIN CIRCUIT BREAKER VOLTAGE 720 I208 V 1 , NEW LOAD ON EXISTING CIRCUIT BREAKER. � � U 36245 7Ci - WIRE { W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. PHASE 3 PH 2. EXISTING LOAD REMOVED. � '0 � � (r'� TYPE '. S�UARE DICUTLER HAMMER 4. EXIST4NG LOAD ON NEW CfRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. WIRE 4 W 3, EXISTING LOAD IS ESTIMATED ��TrIAY 3 1 • (V�� MTG, : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED, TVPE ', ITE �i� � •..��������\a���`' 6. NEW LOAD. MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLY R4TED) '!i���f`S'S/�'NIA1 IEt�`\���`� BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP I P CCT PH CCT AMP / P TOTAL GENER4L OTHER MOTORS RECEPT LTG DESCRIPTION NOTE BREAKER BREAKER 58�2 288 288 151 1 A 2 t5l 288 286 S&3 NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP ( P CCT PH CCT AMP f P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE 288 288 I 3 B 4 / 288 288 R-TR4NS. RM 146 900 900 20 I 1 1 A 2 20 I 1 900 900 R-ANALY. RM 145-140 288 288 I 3 5 C 6 / 3 288 288 R-TRQNS. RM 146 900 900 20 / 1 3 B 4 20 / 1 900 900 R-ANALY. RM 145-140 BF-2 1657 1657 20 I 7 A 8 20 / 1 500 500 SB•2 CONTROL CIR. R-TRANS. RM 146 900 900 20 I 1 5 C 6 20 / 1 900 900 R-RM 144-142 1657 1657 I 9 B 10 20 I 1 1176 1178 EF-i R-TR4NS. RM 146 900 900 20 / 1 7 A 8 20 / 1 900 900 R-RM 144443 1857 I657 I 3 11 C 12 20 / 1 500 500 S&3 CONTROL CIR. R-TRANS. RM 146 9�� 900 2� I t 9 B 1� 20 ( 1 B�� 900 R-LA8 BACT. 2 SB•1 NREF! #REF! 15 / 13 A 14 I 500 500 SB•1 CONTROL CIR. R-TR4NS. RM 146 900 900 20 / 1 11 C 12 20 / 1 900 900 R-LAB BACT. 2 #REF! #REF! I 15 B 16 / 0 SPACE R-TRANS. RM 146 900 900 20 / 1 13 A 14 20 I 1 900 900 R-SHIPPING/RECEIVE 2 XREF! #REF! I 3 17 C 18 / 0 SPACE R-TR4N5, RM 746 900 900 20 / 1 15 B 18 20 / 1 1440 7 ,440 (E) VERIFY LOAD 3 SPACE 0 I 19 A 20 / 0 SPACE REC-LABN. WALL 900 900 20 / 1 17 C 18 20 / 1 1440 1 ,440 R-OB/ORAREAS SPACE 0 ( 21 8 22 / 0 SPACE R-SHANNEX 1 ,080 iQ80 20 ( 1 19 A 2a 20 ( 1 900 900 R-LA6 SPACE 0 / 23 C 24 / 0 SPACE 3 (E) VERIFY LOAD 1 ,440 1440 20 / 1 21 B 22 20 / 1 600 800 R-KITCHEN REFRIG PHASE LOADING SUMMARY PANEL LOADING SUMMARY R-SH ANNEX 1 ,080 1080 20 / 1 23 C 24 20 I 1 360 360 R- RM724 LOAD TYPE (VA) PH A PH B PH C LDAD TYPE CONNECTED NEC CALCULATED POWER DEMAND FREEZER DEFROSTE 0 20 / 7 25 A 28 20 / 1 0 SONIC SINK - CLE4N V ai 1 LOADKVA DEMANDLOAD FACTOR LOADKW PANEL 3 R-HALLWAY,SHIPPIN 1 ,440 1440 20 / 1 27 B 28 20 / 1 0 R-DENTALCHAIR CONNECTED PF= R-SH ANNEX 1 ,080 1080 20 / 1 29 C 30 20 / 1 900 900 R-RM 711/112 LIGHTING 0.0 KVA v 125% • 0.0 KVA z 95% = 0.0 Kw #REF! R-SH ANNEX 1 ,080 1080 20 I 1 31 A 32 20 / 1 900 900 R-RM 110A08 V alley LIGHTING 0,0 0.0 0.0 RECEPTACLES R-SN ANNEX 1 ,080 1080 20 / 1 33 8 34 20 / 1 300 180 120 L-R•CANVALK RECEPTACLES O.D 0.0 0.0 FIRST 1 D KVA 0.0 KVA x 100°!0 = 0.0 KVA x 100°l0 = 0.0 KW CONNECTED R-SH ANNEX 1 ,080 1080 20 ! 1 35 C 36 20 ! 1 1500 1 ,500 (E) VERIFY LOAD 3 MOTORS #REF! NREF! #REF! REMAINDER 0.0 KVA x 50% � 0.0 KVA x 100% = 0.0 KW AMPAdTV = SPACE 0 20 / 1 37 A 38 20 / 1 0 SPARE OTHER 1000.0 0.0 500.0 MOTORS ffREF! MAMMOGRAPHYUNI 1 ,800 1800 20 / 1 39 B 40 30 / 1591 1 ,591 IMI �NUCMED � �2 Medical GENERAL 0.0 0.0 0,0 LARGEST #REF! KVA z 125% _ #REF! KVA t 90% _ #REF! Kw MAMMOGRAPHY UNI 1 ,800 1800 20 I 1 41 C 42 / 2 1591 1 .591 TOTAL #REF! #REF! #REF! REMAINDER #REF! KVA z 100°/ = tREF! KVA x 90% • tREF! Kw NEC DEMAND PHASE LOADING SUMMARY PANEL LOADING SUMMARY PHASE BALANCE A-B B•C C-A OTHER 1 S KVA x 125°l0 = 1 .9 KVA x 100°Jo = 1 .9 Kw AMPACITY = GENERAL NOTES: BREAKER ACGESSORIES NREF! tREF! #REF! GENERAL 0.0 KVA v 100°/ = 0.0 KVA z 100% = 0,0 Mn' #REF! ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • = GFCI C e nter ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. • • SHUNT TRIP TOTAL #REF! KVA NREF! KVA OREF! Kw GENERAL NOTES: BREAKER ACCESSORIES � ' PROVIDE NEW UPDATED PANEL Df RECTORIES FOR PANELS THAT ARE INCLUDED IN TMIS PROJECT. ` = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENdL. • = SHUNT TRIP EX/ST/NG PANEL "PG-DHM" NORMAL BRANCH Penel Notes: 1200 A MAIN CIRCUIT BREAKER VOLTAGE 2771 480 V 1 . NO CHANGE IN LOAD. THIS BREAKER SERVES AN EXISTING LOAD WHICH IS RELOCATED, 1200A BUS PHASE 3 PH WIRE 4 W TYPE , TOP MTG. : SURFACE 14,000 AMPERE SHORT CIRCUIT R4TING (FULLY RATED) 7YPICAL 9�-0" CEIIJNG OR HIGHER Q c s b � � O q � � � Mp I I I I I I II II II BREAKER BREAKER 4 � � � � ❑ ^ � � � MD NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP I P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE TYPICAL 8'-0' CEILING c C s R� i�� I I I I I I F i rst F oo r SPARE 0 30 ( 1 A 2 20 / 1 � SPACE I I I I I I 0 / 3 B 4 20 I 1 0 SPACE BOTTOM OF DEVICE �H/S �S/S S � I I I I I I " 0 / 3 5 C 6 200 / 17451 17451 ELEV "0" KA36200 � � F F U F � � � � � � N uclear Medicine O TOP OF CABINET � I I I I I I SPARE 0 30 / 9 B 10 / 3 17451 17451 �n �� . ..._. . ... . 6Fo � TOP OF CABINET � � I I I � NOTE� ALL DEVICES IND!CAiED TO BE n�_ � 693 3320 4013 30 / 3 � 3 r+ � a �n i 1662 � ��� '��^i.t ��r, s���crt S P R e m od e i _ - INSTALLED AT DIFFERENT MOUNTING eez ° ceNrER sRO F�. 'y-� � ---� � � ---- -- - - "rAC LJCONTkO� PANE�S I I I I " 683 3320 4013 / 15 B 16 / 3 1662 1662 ' w HEIGHTS AND LOCAlE� WITHIN ONE �� 693 3320 4013 1 3 17 C 18 100 / 21333 21333 X-R4Y #2 � TOP OF CABINET O � � O � � � � STUD SPACE FROM EACH Oi}1ER SHALL ncc-� 7ae5 1465 2o i ie A zo i 2� 333 21333 " x ANN OO � ZAM I I I I ALIGN VERi1CALLY, ON THE SAME SIDE „ „ 3 (� nn n � OF 1HE STUD. WHERE WALL M�UNTED taes iass i 2� e 22 i a 21333 2ts3a Z 0 � � 7 T 7 � � �PBQP 7P�PC �R � � I I I � I TELEPHONES OCCUR OVER LIGHT " taes 1465 / 3 23 C 24 100 / 19390 19390 S4-STEAM GEN (STE IL) 1 � I I I I I I SWITCHES, VOLUME CON1i20LS, ETC. SPACE 0 I 25 A 26 I 19390 19390 " iSTFLSPC '� �p�, OFFSET ONE STUD SPACE. SPACE 0 I 27 B 28 � 3 19390 59390 " 0 ❑° ❑F MS R� I I � I I I SPACE 0 I 29 C 30 80l 10360 10360 STEAMGENSURGER 181 W . Meadow Drive d GFl � � � � � � SPACE 0 / 31 A 32 / 10360 10360 " CENTER 3RD FL. \ ' m Q � QCT7 � � � � � � � � � � � � � SPACE 0 / 33 B 34 / 3 10360 70360 V � II , Colorado Z Z � = Z Z = I I I I II SPACE 0 / 35 C 36 / 0 SPACE 81657 _ ? � ? _ � ? _ � II I II SPACE 0 1 37 A 18 � 0 SPACE .. .. .�. .. � � SPACE 0 / 39 B 40 / 0 SPACE o b io io �o a io �o � � � � � � � SPACE 0 / 41 C 42 / 0 SPACE � 1� v � � v � � 'v II II II SPACE 0 I 43 A 44 / 0 SPACE v • • ' • • II II II SPACE 0 / 45 B 46 30 / 3490 3490 ENDO RM RTUTHRU FMR o�i � m � n b u�i � °r SPACE 0 I 47 C 48 ( 2 3490 3490 " FlNISHED ROOR SPACE 0 / 49 A 50 20 / 1 0 SPACE SPACE 0 / 51 B 52 20l 1 0 SPACE TYPICAL DEVICE MOUNTING HEIGHTS PHASELOADINGSUMMARY PANELLOADINGSUMMARY LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND NO SCALE LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL °°""E°TE° PF- ELECTRICAL N0�$: LIGHTING 0.0 KVA x125% = O.OKVA s95% = O.OKW 97% 1 . HEIGHTS SHOWN ARE TIPICAL TO CEN7ERLINE OF BOX UNLESS N07ED OTHERWISE. ucHTiNC o.o 00 0.o RECEPTACLES D ETAI LS AN D RECEPTACLES 0.0 0.0 0.0 FIRST 10 KVA 0.0 KVA x 700% = 0,0 KVA x 100°/ = 0.0 icw CONNECTED 2. WriERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF MoroRS teeae.o 2soss.a 23oas.o REMAINDER O.a KvA x5o� = o.oKVra xtoo°� � o.okw AMPACITY = DOOR TRIM AND CEILING LINE. orHeR sa73z.o 3a7az.o aa�32.0 MoroRS zats PAN E L S C H E D U LES GENER4L 21333.0 21333.0 21333A LARGEST 52.4 KVA x 725% = 65.4 KVA x 90% = 58.9 icW 3. MOUN�ING HEIGH7S SHONIV ON ARCHI1ECiURAL ELEVAiIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. Torq� 75674.0 79164.0 79164.0 REMAWDER 13,5 KVA x 100°/ = 13S KVA x 90% = 12, 1 Kw NEC DEMAND PHASE BALANCE A-B B-C C-A OTHER 1042 KVA z 125% = 1302 KVA z 100% = 13D2 Kw AMPAGTY = DATE 2 APRIL 2007 9-� 4-�6 16•1431 0.0 0.0 0,0 GENERAI 64.0 KVA z700% = 64,OKVA z100% � 64,Oicw 328.5 TOTAL 234,0 KVA 273.iKVA 2652 �cw DR,4WN BY GENERALNOTES', BREAKERACCESSORIES CHK'D BY KRB ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS TMAT ARE INCLUDED IN THIS PROJECL ' = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INOICATE NEW SPARES IN PENCIL. •• s SHUNT TRIP SHEET FILE P-ELSD COPYRICHT 2005 BY DAV1S PARrNERSHIP P.C., MCNRECIS SHEEf NUMBER: E5 . 01 Gator, Ruma & Assoa FILENAME: P: VVMC 2006- 367 NUCLEAR MEDICINE REMODEL CAD\ELEC P-EDS.DWG _ E5.01 PLOT: 05 31 /2007 � 17 : 19am REV: 05 31 2D07 CAD: KBathke XREF: tb.dwg � EX/ST/NG PANEL " EM18 " EQUIPMENT BRANCH EX/ST/NG PANEL " EC1 B " CRITICAL BRANCH , Panel Notes: Panel Notes: 100 A M.L.O. VOLTAGE 120/ 20B V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. 225 A M.L.O. VOLTAGE 120/ 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. . P H A S E 3 P H 2. E X I S T I N G L O A D R E M O V E D. P H A S E 3 P H 2. E X I S T I N G L O A D R E M O V E D. WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKERAS SHOWN. WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. TYPE ; ITE TYPE : SIEMENS • � � Archit �S MTG. : SURFACE 10,000 AMPERE SNORT CIRCUIT R4TING (FULLY R4TED) MTG. : FLUSM 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RATED) BREAKER BREAKER I i BREAKER BREAKER NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL % AMP / P CCT PH CCT AMP I P TOTAL GENERAL OTHER MOTORS � RECEPT LTG DESCRIPTION NOTE NOTE DESCRIPTION i LTG � RECEPT MOTORSI OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P TOTAL GENERAL OTHER MOTORS RECEPT LTG DESCRIPTION NOTE SH COMP RM 0 ' 30 I 1 1 A 2 20 I 1 0 LTG HALL BY KITCH PANEL "EC1C" I 0 . 80 I 1 A 2 20 / 1 0 L-PRE OPIRECOV 1 EF4 I 864 864 I, 20 / 1 3 B 4 20 I 1 0 LTG ELEV LOBBY 0 � / 3 8 4 20 / 1 0 R-SHF COPIER 4. SQ. PHONE CATIPOL 0 20 I 1 5 C 6 20 / 1 0 HEATER ELEV HYDR L " 0 I 3 5 C 6 20 / 1 0 R-SHf COPIER 0 COMBO BOX �AHU 0 15 / � 7 A 8 20 l 1 0 LTG OB MALLWAY R-CARDIO ABG 0 20 / 1 > A B 20 l 1 1136 i � 1136 L- NUC MED,SPC,STE IL@,2 �MOTOR 0 I 9 B 10 20 / 1 0 HALL FIRE DOORS E T LIGHT R-IT 0 20 I 1 9 B 10 20 / 1 1080 1080 R-NUCMED,WORK,INJ C 2 2301 BLAKE ST. , STE. #100 NURSERY 0 / 3 11 C 12 20 / 1 0 SHOP FAN &T.P AT 8. R-RECOVERY (VERIF LOAD) 0 20 I 1 11 C 12 20 I 1 0 R-SHF OFFICE z DENVER, COLORADO 80205 0 1 S1-STERILIZER ' 1800 ! 1800 20 / 1 13 A 14 20 / 1 0 GEN RELAV L-NURSE/EXAM � 0 20 / 1 13 A 14 I 20 / 1 o R-sHF nNNex � � 303.861 .8555 F.303.861 .3027 1 S2-STERILI2ER 1800 '�, 1800 20 / 1 15 B i6 � 20 / 1 0 OLD FACP (E) VERIFY LOAD I 0 20 / 1 15 B i6 20 I 1 500 500 R-NUC MED COMP 1 , 1 ,2 0225 MAIN STREET . UNIT C101 FAW SVS GEN 0 20 / 1 17 C 18 20 / 1 0 � DIEMSION LABI MED ECORD R-RECOVERY 0 20 / 7 17 C 18 20 / 1 500 500 R-NUC MED COMP 1 , 1 ,2 e BROILER CONTROL 0 20 I 1 19 A 20 20 / 1 0 BLR RM 2 LTG L-STORAGE 0 20 I 1 19 A 20 20 I 1 0 R-SH ANNEX EDWARDS, COLORADO 81632 REG ENDOSCOPY 0 20 / 1 21 B 22 20 I 1 0 � TP� OR80B (E) VERIFY LOAD 0 20 / 1 21 B 22 20 / 1 0 SPARE 2 970.926. 9 . . O GR AUTOMATIC DOO S 0 20 I 1 23 C 24 30 / 1 0 . � NEW PHONE EQUIP R-LABOR 2 0 20 I 1 23 C 24 20 I 1 0 R-RECOVERY (VERIF LOADO PHASE LOADING SUMMARY PANEL LOADING SUMMARY R-CR4SH CART 0 20 / 1 25 A Z6 20 / 1 0 (E) VERIFY LOAD GENERAL NOTES: BREAKER ACCESSORIES R-LABOR 1 ! I 0 . 20 / 1 27 B 28 20 / 1 0 VIEWBOX READING R ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • = GFCI R-IT 0 i 20 / 1 29 C 30 20 / 1 0 R-SHF COMP ' PROVIDE NPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ' = SHUNT TRIP R-IT O I 20 / 1 31 A 32 20 / 1 0 L-LAB e 2 SPARE � 0 ; 20 ! 1 33 B 34 20 / 1 D '�. � SPARE R-CARDIOABG � 0 '� 20 / 1 35 C 36 20 / 1 0 : � NURSECALL e 2 SPARE i 0 30 / 37 A 38 20 / 0 SPARE 2 2 0 I 2 3B 8 40 I 2 0 EXISTING PANEL ��EM1 C�� EOUIpMENT BR4NCH R-STORAGE 121 0 20 / 1 47 C 42 ' 20 / 1 0 (E) VERIFY IOAD SINGLE GANG PLASIER RING Wlhl 0 PHASE LOADING SUMMARY PANEL LOADING SUMMARY GROUND SCREW AND PIGTAIL TO Panel Notes: GENER4L NOTES: BREAKER ACCE3SORIES MATCH DRYWALL 1HICKNESS M .L.O. VOLTAGE 1201 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. 125 A BUS PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. ' • GFCI WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKERAS SHOWN. ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. • = SHUNT TRIP TYPE : SQUARE D 4. EXISTING LOAD. EXISTING LOAD IS ESTIMATED. Q MTG. : SURFACE "[ �" AMPERE SHORT CIRCUIT RATING (FULLY RATED) 5. EXISTING LOAD REMOVED. 6. NEW LOAD. � � BREAKER BREAKER : ' �' � EX/ST/NG PANEL ��LPA �� NORMALBRANCH RECEPTACLE BOX SUPPORT DETAIL NOTE i DESCRIPTION LTG ' RECEPT IMOTORS OTNER GENERAL TOTAL AMP I P CCT PH CCT AMP I P TOTAL GENER4L OTHER MOTORS RECEPT LTG DESCRIPTION NOTE 4 " ! i 1000 �000 � 20 I '. 1 A 2 20 / 1 800 600 CO. MED COMPUTER 4 Panel Notes: 3 PANEL EMiCA 0 0 2521 1000 i o . � 000 / 2 3 B 4 20 / 1 800 800 CO. MED COMPUTER 4 225 A MAIN CIRCUIT BREAKER VOLTAGE 120 I 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. , f� T1 A (? n NO SCALE 4 sanRe ' 0 20 / 1 5 C 8 20 / 1 1000 1000 FREE2ER 4 PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTING. C,A'1 UR, RIAMl1 U f1SSUL,I.�TES, CU. 3521 50 / 7 A B ' 30 / 2000 2000 I E�. CLOSET I 4 WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. CUNSULTING MECHANtCA1/ELEC7RICAL ENGWEERS OJ-� 4-OB 16135.3 ° 0 0 3697 0 0 ' 3697 / �9 B 10 I / 2 2000 2000 I " �' 4 TYPE : ITE 1. EXISTING LOAD ON NEW CIRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. 0 0 2521 500 0 3021 / 3 11 C 12 20 / 1 0 I SPACE I MTG. : FLUSH 10,000 AMPERE SHORT CIRCUIT RATING (FULLY RA7ED) 5. EXIS7ING LOAD REMOVED. 1550 Dover Street . Su�te iwo . Lakewood, CO 60215-3132 4 PACS 208V -RADIOLO Y 1000 1000 20 / 1 13 A 14 20 / 1 0 I SPACE 6. NEW LOAD. 303l232•6200 . Fex 303/233-3701 4 PACS208V -RADIOLO Y 1000 1000 20 / 1 15 B 18 20 / 1 0 SPACE I BREAKER BREAKER cre([�catorruma.com . wumv.catorruma.com SPACE 0 20 / 1 17 C 18 20I1 0 'SPACE NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL '. AMP I P CCT PH CCT AMP / P TOTAL GENERAL OTMER MOTORS RECEPT LTG DESCRIPTION NOTE SPACE ' 0 20 ! 1 19 A 20 20 / 1 0 ! i SPACE HEAT PUMP 0 20 I 1 A 2 20 I 1 0 LTG-LAB SPACE 0 20 / 1 21 B 22 20 ! 1 ' 0 � SPACE -- 0 �� I 3 B 4 20 / 1 0 REC-IRADMINOFF. ISSUE/REVISION DATE NO. ISPACE 0 20 I 1 23 C 24 20 / 7 0 SPACE 0 / 3 5 C 6 20 I 1 0 �� WIREMOL6ADMIN 0 F. SPACE 0 20 / 1 25 A 28 20 I i � 0 i SPACE FAN COIL UNIT I 0 20 / 1 7 A B 20 / 1 0 REC- IR ADMIN 8 BAT TOV COMMENTS OB-O 'I -O� Q SPACE ' 0 20 I 1 27 B 28 20 / 1 O I SPACE I-NORTH CORRIDOR 0 20 I 1 9 B 10 20 / 1 0 REPEXAM RM 29 SPACE 0 20 / 1 29 C 30 20 I 1 0 SPACE SPARE 0 20 / 1 ii C 72 20 / 1 0 REC-IRADMINOFF. PHASE LOADING SUMMARY PANEL LOADING SUMMARY LTG-EM RM 0 20 / 1 13 A 14 20 / 1 0 REC-MAMMOGRAPHY LOAD TYPE (VA) PH A PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND � REC-ADMIN OFFICES 0 20 / 1 15 B i6 20 ! 1 0 DENTAL X-R4Y LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL HEAT CONTROLS 0 20 / 1 17 C 18 20 / 1 0 DENTAL CHAIRS CONNECTED PF= CONDENSING UNIT 0 20 I 19 A 20 30 / 1 0 EXISTING LOAD LIGHTING 0.0 KVA x 125°h = 0.0 KVA x 95% • 0.0 KW 95°/a 0 / 2 21 B 22 20 / 1 0 REGSTORAGE LIGHTING 0.0 0.0 0.0 RECEPTACLES DENTAL XR4Y 0 20 / 1 23 C 24 20 I 1 0 REC-ULTRASOUND U IT RECEPTACLES 0.0 0.0 0.0' FIRST 10 KVA 0.0 HVA z 100% = 0.0 KVA x 100°h = 0.0 icw CONNECTED DENTAL XR4Y 0 20 I 1 25 A 26 20 I 1 0 REC-ULTR4SOUND T IL MOTORS 2521 .3 3697.3 3521 .3'�, REMAINDER 0.0 KVA x 50% = 0.0 KVA x iD0% = 0.0 Kw AMPACITY = LTG-BASEMNT STOR. '� 0 20 / 1 27 B 28 20 / 1 768 720 68 REC-NUCLEAR MED 1 ,5 OTHER 1000.0 0.0 500.Oi MOTORS 57.8 KITCHEN HEATED 'i 0 20 I 1 29 C 30 20 I 1 720 720 R-SPC,STERILE,NUC E�,5 GENER4L 4800.0 4600.0 0.0� LARGEST 7.8 KVA z 125% = 9.5 KVA x 90% = 8.5 KW PLATE DEISPENSER i 0 20 / 1 31 A 32 20 / 1 0 PARKING GATE TOTAL 8321 .3 8497.3 4021 .3I REMAINDER 2.2 KVA z 100% = 22 KVA x BO°/ = 2.0 icw NEC DEMAND LTGCOMPACTOR 0 20 I , 33 B 34 20 I 1680 1 ,880 53-STERILIZER 3,5 PHASE BALANCE A-B B-C C-A OTHER 1 .8 KVA : 125% = 1 .8 KVA x 100% • 1 .9 itw AMPACITY • LTG-SIGN 0 / 2 35 C 36 / 1880 1 ,680 5 0.0 1 .1 1 .1I GENER4L 9.8 KVA x 100°/a • 9.6 KVA x 100% = 9.6 KW 64.1 COMPACTOR 0 20 I 37 A 38 I 3 1680 1 ,680 0 / 39 B 40 20 / 1 0 �. REPSTORAGE REFRI TOTAL 20.8 KVA 23.1 KVA 21 .9 �v � 0 � I 3 41 C 42 30 / 1 0 '�� LTG- ULTRASOUND M MMO " .. . ....._.....__ , GENERAL NOTES: BREAKER ACCESSORIES PHASE LOADING SUMMARY PANEL LOADING SUMMARY ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • � GFCI GENERAL NOTES�, BREAKER ACCESSORIES ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ' = SHUNT TRIP ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT. • = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. ' = SHUNT TRIP EXIST/NG PANEL "EM1CA " E�UIPMENTBRANCM ����\\"11I11"IIf'/������ ����� 0� REG�S �9j��. � EX/ST/NG PANEL "LPL " NORMAL BRANCH �.`Op�.•'EAIViy••TF �'''•, Panel Notes: � . Bd'A� y � v . O 50 A MAIN CIRCUIT BREAKER VOLTAGE 1201 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER, Panel Notes: ? O� �j� ¢t 100 A BUS PHASE 3 PH 2. PROVIDE NEW CIRCUIT BREAKER IN SPACE TO MATCH EXISTWG. 225 A MAIN CIRCUIT BREAKER VOLTAGE 120 / 208 V 1 . NEW LOAD ON EXISTING CIRCUIT BREAKER. U '= 45 � WIRE 4 W 3. REPLACE EXISTING CIRCUIT BREAKER WITH NEW CIRCUIT BREAKER AS SHOWN. PHASE 3 PH 2, EXISTING LOAD REMOVED. c �U 3 � r� TYPE �, SQUARE D/CUTLER HAMMER 4. EXISTING LOAD ON NEW CIRCUIT BREAKER. EXISTING LOAD IS ESTIMATED. WIRE 4 W 3. EXISTING LOAD IS ESTIMATED '�' �•p1AY 3 1 20�� _ _ _ TLOAD.OAD REMOVED, MTG. : SURFACE 10,000 AMPERE SHORT CIRCUIT RATING (FULLV RATED) ��i�� �.�^�������'�� 5. EXIS 6, NEW _ _ . ' _ .._.._. . .__..._.._- __.__ . . . NOTE . � ,. .., . ...... ._ _ � -. .. .__,I._ -- ...... . .._. -�-. .,..'.-� ----�---` _...- ��4jn.,J��A:�. BREAKER BREAKER DESCRIPTION LTG RECEPT , MOTORSI OTHER � GENER4L TOTAL �, AMP / P ' CCT PH CCT � AMP / P TOTAL GENERALi OTNER MOTORS � RECEPT LTG DESCRIPTION NOTE j BREAKER BREAKER � I �-r . , -- � � - �w��� 'SB-2 � ' 288 I, 268 15 � 1 A 2 � 15 / 288 288 SB3 � NOTE DESCRIPTION LTG RECEPT MOTORS OTHER GENERAL TOTAL AMP / P CCT PH CCT AMP / P ' TOTAL GENERAL ���. OTHER ��. MOTORS RECEPT LTG � DESCRIPTION NOTE ._" �. _ __.._._... ..- - � __".' -_.. . _......'___.. ._....._ ... ........ � 288 � 288 / 3 B 4 � / 288 ' 288 � i R-TR4NS. RM 146 900 � 900 20 / 1 1 A 2 20 / 1 900 �' i 900 R-ANALY, RM 145-140 ' � �� 288 288 I 3 5 C 6 / 3 i 288 � � 288 '�. '� R-TR4N5. RM 146 900 900 20 / 1 3 B 4 i 20 I 1 900 900 R-ANALY. RM 145-140 , BF-2 1657 1657 20 / 7 A 8 20 I 1 500 500 � S&2 CONTROL CIR. ' R-TR4NS. RM 146 ' 900 900 20 / 1 5 C 6 20 / 1 900 900 R-RM 144-142 � _.... ,..._ 1657 1657 / 9 B 10 20 / 1 ' 1176 '� 1176 � IEF-1 R-TR4NS. RM 146 900 ' 900 20 I 1 7 A 8 �� 20 I 1 900 900 R-RM 114-143 1657 1657 / 3 11 C 12 20 I 1 ' S00 I 500 '� !SB3 CONTROL CIR. R-TR4NS. RM 146 900 � 900 20 / 1 9 B 10 20 / 1 900 , 900 R-LAB BACT. 2 SB-1 288 288 15 / 13 A 14 I 500 ' S00 ' ;S&1 CONTROL CIR. R-TRANS. RM 146 900 900 20 ! 1 ��, 11 C 12 20 / 1 900 '�. 900 R-LAB BACT. ___'.. .._.. ....___- � ' 288 28B / 15 B i6 I O I iSPACE R-TRANS. RM 146 900 900 20 I 1 ; 13 A 14 20 / 1 900 900 R-SHIPPING/RECEIVE _. . . . . ........_.._ : 288 288 I 3 17 C 18 / 0 � SPACE �R-TR4N5. RM 146 900� ' 900 20 / 1 75 B 16 20 / 1 1440 1 ,440 (E) VERIFY LOAD 3 SPACE 0 , / ''� 19 A 20 I 0 �SPACE IREGLAB N. WALL � 900'�� �� 900 20 I 1 , 17 �C 18 20 / i i 1440 1 ,440 R-OB/OR AREAS SPACE � 0 '�. I �, 21 g 22 / 0 ' SPACE IR-SHANNEX 1 ,080 1080 20 / 1 19 A 20 20 I i � 900 900' R-LAB SPACE � 0 � / � 23 C 24 I 0 ��� SPACE 3 (E) VERIPV LOAD 1 ,440 '� 1440 20 I 1 21 B 22 20 / 1 800 600� R-KITCHEN REFRIG PHASE LOADING SUMMARY PANEL LOADING SUMMARY R-SH ANNEX 1 ,080 1080 i 20 / 1 23 C 24 20 I 1 �' 360 360 R- RM124 LOAD TYPE (VA) PH A PH B PH C�� LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND FREEZER DEFROSTE 0 � 20 / 1 25 A 26 20 / 1 I 0 I SONIC SINK - CLEAN V ail ��� LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL 3 R-HALLWAY,SHIPPIN 1 ,440 1440 '� 20 / 1 27 B 28 20 / 1 0 � � R-DENTAL CHAIR CONNECTED PF= R-SH ANNEX 1 ,080 1080 � 20 / 1 29 C 30 20 I 1 900 900 R-RM 7111112 � . . . . ..,.. .. _ LIGNTING 0.0 KVA x 125% = 0.0 KVA x 95%a • 0.0 KW 92%a R-SH ANNEX 1 ,080 '� 1060 20 / 1 31 A 32 20 / 1 900 900 R-RM 110/108 _ „_ vall ey LIGHTING 0.0 0.0 0.0 RECEPTACLES R-SH ANNEX 1 ,060 '� 1080 �� 20 / 1 33 B 34 �, 20 / 1 300 180 120 L-R-CATNALK RECEPTACLES 0.0 0.0 0.0 FIRST 10 KVA 0.� KVA x 100% = 0.0 KVA x 100% = 0.0 KVJ CONNECTED R-SH ANNEX 1 ,080 1080 20 / 1 35 C 36 I 20 / 1 1500 1 ,500 (E) VERIFY LOAD 3 MOTORS 2521 .3 3697.3 2521 .3 REMAINDER 0.0 KVA z 50°/ = 0.0 KVA z 100% = 0.0 �/ AMPACITY = SPACE 0 20 I 1 37 A 3B 20 I 1 0 . SPARE GENERAL 0.0 0.0 0.0 LARGEST 5.0 KVA z125Da • 6.2KVA z90% = S.6Kw MAMMOGRAPHYUNI � � 1 ,800 1800 20 � � � 39 B 40 30I 1591 � 1 ,591 '�. IM1 -NUCMED � �2 Medical OTHER 1000.0 0.0 500.0 MO?ORS 28.4 MAMMOGRAPHY UNI _ 1 ,800 1800 20 / 1 o _ ' I 41 C 42 / 2 1591 � 1 ,591 TOTAL 3521 .3 3697.3 3021 .3 REMAINDER 3.8 KVA x 100 h = 3.8 KVA z 90% 3,4 �cw NEC DEMAND PHASE LOADING SUMMARY PANEL LOADING SUMMARY � PHASE BALANCE A-B B-C C-A OTHER 1 .4 KVA x 125% = 1 .9 KVA x 100% • 1 .9 k/a - AMPACITY � GENERAL NOTES: BREAKER ACCESSORIES C ente r 0.0 02 02 GENERAL 0.0 KVA x 100% = 0.0 KVA z 100% = U,0 �cw 32,9 ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN THIS PROJECT, • = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. • = SHUNT TRIP TOTAL 102 KVA 11 .9 KVA 10.9Kw GENERAL NOTES: jBREAKER ACCESSORIES �1 ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS TF1AT ARE INCLUDED IN THIS PROJECT, �• = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENGL. ' ' = SHUNT TRIP EXIST/NG PANEL "PG-DHM" NORMAL BR4NCH Panel Notes: 1200 A MAIN CIRCUIT BREAKER VOLTAGE 2771 480 V 1 . NO CNANGE IN LOAD. THIS BREAKER SERVES AN EXISTING LOAD WHICH IS RELOCATED. 1200A BUS PHASE 3 PH WIRE 4 W TYPE , TOP MTG, ; SURFACE 1/,000 AMPERE SHORT CIRCUIT RATING (FULLV R4TED) TYPICAL 9'-0' CEILING OR HIGHER Q � 5 � �1 � � n � � � �p I I I I I I ___ IJ LJ' Y BREAKER BREAKER I TOp Po I I I I � I NOTE DESCRIPTION �'� LTG I RECEPT MOTORS OTHER ' GENER4L ��, TOTAL i AMP / P CCT PH CCT �, AMP / P TOTAL IGENERAL OTHER � MOTORS RECEPT '� LTG DESCRIPTION � NOTE F i rst F I oo r TYPICAL 8'-0" CEIIJNG c c s � ,� �J �j �Q I I I I I I --"-Y -- - - 4 � L_J IJ ❑F T Y �"P M� I I I I I I ,SPARE I i, 0 30 / 1 A 2 20 / 1 0 SPACE i" � 0 / 3 8 4 20 / t 0 '�, ._._.. .. ...__ SPACE BOTTOM OF DEVICE �H/5 �5/5 � � I I I I I I I 0 / 3 5 C 6 200 I 17451 i 17451 ELEV "0" KA36200 �SPARE � 0 30 I 7 A 8 / i 17451 "' 17451 o TOP OF CABINET � ` F F � � � � � � - -- o , 9 8-- -- , o „ , ,,5, , „45, Nuclear Medicine I � + + I I ��" 0 I 3 11 C 12 60 I 1662 '� � 1882 �STEAM GEN SURGER S P C R e m o d e � � � � � z TOP OF CA8INET I I I I `uTc: ALL �7cYICcS iNDiCAiau i� BE �NG-1 6b3 , 332u 4GS3 sG r I "s n 74 i IoG[ Vuo2 i " OENTcR3rtur�. � {� FAC QCONTROL PANELS I I I I INSTALI.ED AT DIFFERENT MOUNIING 693 , 3320 4013 � / 15 B i6 / 3 1862 1662 i w HEIGHTS AND LOCAiED WITHIN ONE - -- se3 aazo 40� 3 i 3 t� c te �ooi 21333 2� asa x-ft.4va2 � � ' �. � TOP OF CABINET � � � � STUD SPACE FROM EACH OiHER SHALL _' -- � ae5 ' 2o i �e a, zo i- z� ss3 _ 2� 333 s4-s7eqht �eN (sre 2 ANN O Q �❑ zAU I I I I ALIGN VERTICALLY, ON 1HE SAME SIDE a,ca� �asa � ; (� [� [q (� (� (� OF 1HE STUD. YhIERE WALL MOUNTED 1485 � ues i 2� e 22 i 3 2� 333 21333 I j 0 � � 7 � Y � 7 IPB 7P 7P�PC �R F❑ F❑ � I a I I I �ELEPHONES OCCUR OVER LJGHT tass � us5 / 3 23 C 24 100 I 19390 19390I IL) 1 $WITCHES, VOLUME CONTROLS, ETC. SPACE 0 / 25 A 26 / 19390 19390 � " iSTFLSPC � I I I I I I OFFSET ONE STl1D SPACE. SPACE I 0 I 27 8 28 / 3 19390 19390 " � ° °�" S � �Fl i i � � � �� i -- 181 W . Meadow Drive �SPACE � 0 �l 29 C 30 80 I . 10360 �, 10360 STEAM GEN SURGER � ��SPACE -_ ' ' � - 0 / 31 A 32 / �� 10360 '� ��� 10360 " CENTER3RDFL. va � l , Colorado Q � � Cj7 � � � � � � � � � � � � � '�,SPACE 0 i / 33 B 34 / 3 10360 I 10360 � �., � _.. SPACE __ ,, ____ p / 35 C 36 , o - SP^°E � 81657 ^ ^ ^ ` � � %�II II SPACE o � 31 A 38 � I 0 ` � , SPACE � � o � ---- � � � ? j = � � = SPACE _ 0 / �, 39 B 40 �. I 0 I SPAC ,C z z � � II I II SPACE 0 . 0 0 'm io o a io o i �� i v ,v v i i i _v v I I I I I I --- -.. . . _.... _...__ i_ a� c �- nz I i ___ � - . .. . ._.._ SPACE _ uo T� �u io v in w � SPACE '� � 0 / 43 A 44 / 0 �, � SPACE -- v � FINISHED FLOOR I I I I I I '�,SPACE '� , .......... 0 _..... .l ... . .. ..49 A 50 20 / 1 , p 3490 SPACE FMR . . . . . . � . SPACE 0 / 45 B 46 30 / 3_49_0 �� i 3490 ENDO RM RTU THRU o�i � � � n e v�i � °� SPACE 0 I 47 C 48 / 2 3490 , � _-�- -.... 'SPACE 0 , I 51 B 52 20 I 1 0 � i SPACE � TYPICAL DEVICE MOUNTING HEIGHTS PHASELOADINGSUMMARY _ __ _�_ __ PANELLOADINGSUMMARY _ _ LOAD TYPE (VA) PH A� PH B PH C LOAD TYPE CONNECTED NEC CALCULATED POWER DEMAND NO SCALE �I, LOAD KVA DEMAND LOAD FACTOR LOAD KW PANEL '�, CONNECTED PF= E LECTRI CAL NOTES: LIGHTING 0.0 KVA z 125% = 0,0 KVA z 95% = 0.0 KW 97% 1 . HEIGHTS SHOH?J ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. u�H7iNC o.o o.o o.o RECEPTACLES DETAILS AND RECEPTACLES 0.0 0,0 0.0 FIRST 10 KVA 0.0 KVA x 100% = 0.0 KVA z 100% = 0,0 �cw CONNECTED 2. WHERE EVER DEVICES ARE INDICAiED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED BETWEEN TOP OF MoTORS 19609.0 23099.0 23099,0 REMAINDER 0.0 KvA x50% = O.OKVA x100% = o,0icw AMPACITY = DOOR TRIM AND CEILJNG LINE. o7HER 34732.0 34732.0 34732,0 MOTORS Z8� .5 PANEL SCHEDULES GENERAL 21333.0 21333.0 21333.0�� LARGEST 52,4 KVA x 125% = 65.4 KVA x 90% = 58.9 kw 3. MOUNIING HEIGHTS SHOWN ON ARCHITECNRAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. 7orA� 75674,0 �e� e4,o 79164.0 REMAINDER 13.5 KvA xt00% = 13.SKVA zEO°io = � 2 � Kw NEC DEMANO PHASE BALANCE A-B B-C C-Ali OTHER 1042 KVA x 125% = 1302 KVA z 100% = 1302 Kw AMPAGTY = DATE 2 APRIL 2007 9-� 4-�6 � b•� 43.� 0.0 0.0 0.0'�, _ _ GENERAL 84.0 KVA % 100% = 64.0 KVA z 100% = 64.0 Kw 328.5 TOTAL 234.0 KVA 273.1 KVA 265.2 Kw DRAWN BY GENERALNOTES: BREAKERACCESSORIES CHK'D BY KRB ' PROVIDE NEW UPDATED PANEL DIRECTORIES FOR PANELS THAT ARE INCLUDED IN TNIS PROJECT. ' = GFCI ' PROVIDE TYPED DESCRIPTIONS OF NEW CIRCUITS BEING INSTALLED. INDICATE NEW SPARES IN PENCIL. • = SHUNT TRIP SHEET FILE P-ELSD COPYRIOHf ROW BY OANS PARINERSHIP P.C., ARCNRECIS SNEET NUMBER: E5 . 01 Cator, Ruma k Aaaoc. FILENAME: P: WMC 2006-367 NUCLEAR MEDICINE REMODEL CAD ELEC P-EDS.DWG _ E5.01 PLOT: 05 31 2007 0 12: OOpm REV: 05 31 2007 CAD: KBathke XREF: tb.dwg