Loading...
HomeMy WebLinkAboutCascade Village (25) G-4382 UJ I i o J O Q WcoQ ( J J 0 � � Q 1 J ~ °- to W0 Lo WZL +N Z CV 0 0 s OC) 0 T_ QI LL 1LEOE N1/ 3I DOOR NUMBLY? NOTE NUMBER ADREVI tTlO'NS af�) V VJ `� �" A.F.F. Above, Finished Floor RGq d. Required W Wall Outlet , Access i�anel Surface Mounted light Fixture ACT Acoustical calling The S.G. Solid Gore 0 ® Floor Outlet Alum. Aluminum 5F Stain Finish W 0 Exit sign Recessed Wall Spot Light A.P. Access Panel Sect. Section Lo Wall Tcle hone Jack PI 5ht. Sheet d p BP Blank ate 9 ,J-BOx N q Floor TeIG hone Jack @d. Board Sim. Similar CASCADE BALLROOM RENOVATION 1�51 p Wall Sconce CT Carol The 55 Stainless Steel Speaker GPT Gorpet Specs. 5pecifIcotion 1"V/Cable 0 HVAC brills Dti. Detail (] F?owniight Effect. Electrical 5T Stone Tile, Typ. Typical 1 - v Audio / Video .Jack }��( Track Light Fixture EXHAUST .P. Electrical Panel L ST FAN Exist. Existing LINO Unless Noted Otherwise Fir. Floor JON Unless Otherwise Noted Q Thermostat Emergency / Exit Fixture C< 5urfoce Mtd. Spot Light Gyp. 69psurn I r H.M. Hollow Metal V.I,F. Verify In Field $ Switch Mti. Metal V5 Vinyl Ba5D RESORT � Visual Fire Alarm Signal Pendant Light Fixture co ❑ g N.l.c. Not In. Contract V56 Vinyl Sheet Goods sp Dimmer Switch Opp. Opposite I^" ® Supply Register C) Sprinkler Head PT Paint 1�1G Wallcovcring VAII., CASCADE WD Wand FA Fire Alarm Signal EM Z Return Register Emergency Fixture Fire Alarm Pull EXISTING WALL TO REMAIN (May indlcote ceiling Ilnc above) VAIL CO ORADO EXI57IN6 WALL TO BE REMOVED — � — (May indicate, ceiling above,) NEW CONSTRUCTION FIEMONS BY INDEX OF DRAWINGS II C-1 : TITLE SHEET/ GENERAL NOTES, SYMBOL LEGEND/ ABBREVIATIONS EX-1 : EXISTING CONDITIONS FLOOR PLAN 1�E1-IOL I T I ON N07E5 C ENERAL N07E5 D-1 : DEMOLITION PLAN DRC-1 : DEMOLITION REFLECTED CEILING PLAN A-1 : ARCHITECTURAL PLAN ?1 00 I. All demo0tion shall be performed with "due. care and diligence"' so as to pravcnt the 1. Contractor shall visit the site e and thoroughly Familiarize himself/herself with cxlstfng conditions, arbitrary destruction C r Interruption f concealed Ut III i e,5 hl G1 a r e Intended d tG remain VGrif e o cation s, c conduit r out In detc. before submitting bid. An y dl5cr anc I c5 shall be reported RC—1 :1 : REFLECTED CEILING PLAN Q in use and the routing of which could not be determined until demolition started. All such to th owner before the old ate. discoveries of utilities during demolition process which are in a location different from that EL-1 BALLROOM ELEVATIONS Indicated, changed direction from floor to floor, etc, or are unidentified, shall be reported 2. Verlfy location of existing systems (i.e. F/A sound, etc) and associated conduit runs and II�� to the Architect In writing before removal for ffnal disposition. number of conductors. Provide additional condults/conductors to achieve design Intent. EL-2 : BALLROOM / PREFUNCTION ELEVATIONS m 2. Prior to demolition of wails and partitions by the General Contractor, the plumbing, 3. Verlfuq location of existfng exit signs and egress lighting fixtures. Provide new as required EL-3 : BALLROOM / PREFUNCTION ELEVATIONS aI1 mechanical, and GlGctricai trades and any of er contractors believed to have operational and i.shere indicated in drawings. contractor shall verify door swings before irstolling fJ cqutpment, connections and lines inside the wolls shall be notified by the General Contractor light switches. Exit sign to conform to state and local codas. EL-4 : BALLROOM / PREFUNCTION ELEVATIONS Z In writing for Investigation, termination orcl reconnection of any electrical wilring, water W piping, control air tubing, etc. After such work investigation and work has been performed, IF-1 : FINISH PLAN each contractor will notify the General Contractor In writing prior to beginning wall 4- Up-date dtrcctories in all existing panels to ref}act changes, deletions and additions demolition. by this construction. m II construction I removed n I r i FFE-1 FURNISHING PLAN � C J 3 Remove a const uct on des grated to be a oved a d clear to ecc ve new work as 5. Any electrical devices left without power due to this construction shall be reconnected Indicated herein. to same, size GirGuit(5) a5 previously 5Grved No electrical devices shall be raft without E-1.0 : ELECTRICAL POWER SPECIFICATIONS 0 0 power. �r� M 4. Where demolition of exiting work occurs adjacent to or t existing work a remain, DE'-2,O : ELECTRICAL POWER DEMOLITION PLAN u� remove portions of existing construction as drawn and notch to match adjacent } construction. 6. General contractor shall be responsible for sealing all penetrations through rated �j walls and ossemblies wlth approved methods conforming to Underwriters Laboratories E-2.1 : ELECTRICAL POWER PLAN 5. Remove existing partitions, finishes and Gelling as shown in plan. See, Finish Plans tasted systems to aecordanec with building code. Ir r for new finishes and callings. �" 7. All dimcnslons are presumed accurate but not guaranteed to be sa. 6ercral Contractor DE-3.0 : ELECTRICAL LIGHTING DEMOLITION PLAN 0 � 6. Remove existing equipment and seal opening with construction to match adjacent shall verify in Field all dimensions and report any dlscrepone-les to the Architect prior to the and new finishes as scheduled. works commencement. Q 0 8. All work shall comply with state and taco! GaaeS. E-3.1 � ELECTRICAL LIGHTING PLAN py E-4 : PANEL SCHEDULE �3 € �. Wherever existing equipment, piping, ducts, etc, are required to be removed,. such removal � Q shall Include all anchors, hangers, Foundations, etc. After removal, affected construction / { and surfaces such as Floors, walls, bases and Gelllngs shoil be Finished to match adjacent 9. Flame spread rating shall be as follows: a) Acoustical Ceiling Tile = -0.25 (A5TM E-84 W unless noted otherwise. class "A"), b) 5 psum 5d. = Type "X" or (1) hour flre rated. V l L Z 10. 6cneral contractor shall be respon5lbie for preparing all surfoces to recGlve new 0 � W/� 8. All equipment such as shelving, cabinets, plumbing fixtures, electrical fixtures and finishes as Indicated In plans. 'Potch/T�epalr all affected areas as reatulred. v V equipment, mechonicvol equipment, etc. shall be turned over to the owner or, at his W discretion, become the property of the contractor and shall be removed from the Q prcmiscs at no additional cost to the owner. 71 0) J F ca z Q • W ca > > 0 SCALE: N.T.S. owl,: io DRAWN= 0171 JOB F g5O26-21 �1 DATE 12-15-ciG RECEIVED Tier-CO)FAMEV. C = 1 ° c-4asz J__j WINDOW - "-UNO) &-1111 WIDE K/FLAT METAL THRESHOLD ARC TOP. q'-511 H 0 CENTER, 8'-5 1/4" H Q SPRING POINT. DASHED LINE 8 ' SILL HT. = 6". 51GNA67 W DENOTES SCOPE E BELO SCONCE OF WORK J METAL THRESHOLD (TYP) O 0!!�-7„ DOOR STOP F O 1 -0Q AFF LT. SCONCE '• FIRE ALARM PULL TIP. o TYP. TYP. 6” PLEX!- e5LA55 KICK PLATE W {Q HEATER • 11 ' WALL TYP. CENTERLINE WALL 11 (O J PE UNCTION r „ 11 II BRASS CORNER GUARDS SIGN TYP. Uj 0 �-8 H x 2 -6 � I I SCONCE 0 /2 HEATER TIP. 11 -I 4'-0" ABOVE BASE. -2 1/ 21-611 V-61' AFF CARPET FLOORING 4 WOOD AFF I/2" Q Q (21-011H x PANELING W/BRA5S STRIP ^ ''^^ 1'-4"W x 6"D) INLAY m WALL5. WD STAINED -a V, 13'-a I/211 T'. DOORS W/PT HM FRAMES. EXIT 516N W WOOD BASE THROUGHOUT ® 14" A.F.F. II (5"H X 3/4"D) DOOR hV5611H Z WNODOw(BILL 1®2�3/4" AFF N TELEPHONE AND 5" DEPTH 4,-11"W x KIGKPLATE ELE OR � � 0 T• CURVED AT TOP 3-O H OPENING I.C. ` N NlITH COUNTER AND OUTLET FT. I ROLLING II MEG IGAL � 0 N �• A/V STORAGE N N.I.G. ROOM 5 FT MILLWORK TEST ROOM 51 GNAGE ROOM 00 PANEL LOCATION w CASCADE 51GNAGE w OFFICE SHITCH _ TI SERVICE Q I�,I 41 _rJ fl V • WALL V N.I.C. N.I.G. r � LL SHITGH BAND FOR ALL LISHTINS ��•! HOTEL 516 SWITCH BANK • 51-41/20 A.F.F. W a db. O Z z (IS"W ® 31-5" A.F.F.} 0 L4 �_j r T T T ui � N N ' 0 Ck FIRE PULL 1'"0" ® ® m '' ® ® 3 co TD. MTL TER II ® ® app m N (2 1/211XV 43 1/2 A.F.F. ® N.I.G. N Z r LAMINATED FAGS DOOR CV)5X17 THERMOSTATIC m 6311 A.F.F. DOOR STOP TYP. MANE GONTROQ Ib x 24 SCONCE OUTLET ® In I/2" A.F.F. FLOOR DUPLEX II \ Q 5CONCE (TYP) 5TA I R #1 V-5" A.F.F. 1'4"W x 2'-O"h x I I \ / � E 8"D RVISION 17 S 5 FLOOR DUPLEX OUTLET \ / QUAD BP MICROPHONE OUTLET-TYP. II ® X BLANK PLATE - TYP. SP 1111 A.F.F. M!KE �L ROOM GA5GADE BALLROOM LL $P KITCHEN CARPET FLOOR AND WOOD PANELING N.I.G. WITH BRASS STRIP iNLAY AT WALLS. WOOD STAINED DOORS WITH PAINTED 6x17 HOLLOW METAL FRAMES. WOOD BASE THROUGHOUT (5" H X 5/411 D). BP «� z 31_.711 MICROPHONE OUTLET sP BLANK PLATE - TYP. i'DT TELEPHONE - TYP. WASH ct AFF N.I.G. C NOT 5HOWN THIS SIDE .o OF EN TO BEL.ON THERMOSTATIC ® 63" A.F.F. ® NOTE: (3) BLANK PLATE ""' 8 MANE CONTROL) QUAD OUTLET 4 (1) ❑ W � J MICROPHONE OUTLET - ALL u. w 0 SCONCE - • 14 112 A.F.F. ® C M (I) BLANK PALTE QUAD 4} z ® OUTLET ! 511/2" A.F.F. ® W 0 �/� 00E F ® alp/,Iw x ��-10" wlNDOw ,I Q � o (SILL a 1-0 A.F.F. 4 4 1/2 Q DEPTH - TYP) U cd L. z - o BASE RADIATION (TYP) all 0 V Q A.F.F. 4 2 1/2'1 DEEP Q . m FIXED LOUVER 3'-'7" off 0 1 00 U z ® ® ffl/2" 77=- Q 7od (d x X » U w WD. 5HUTTERS (TYP) METAL THRESHOLD (TYP) SLIDING WITH ROLL DOWN SCALE: 1/411 - 11-011 CAEMENT SHADE DRAWN: AT JOB 0 193026-21 r DATE i2-f5-aa EXISTING BONDITIONS FLOOR FLAN 5C.-ALE : 1/41' : EXm1 WOMEN`S j N.I.C. �. 00 ° C-43g^ I DEMOLITION NOTES: I. REMOVE EXI5TIN 6 CARPET, I� 00 POWDER 6 ,.... ._.._.,_.:., 2. REMOVE ALL SCONCES AS THEY ROOM 5. REMOVE EXISTING BRASS DIVIDER STRIPS AT ALL MILLWORK PANELS. PREP TO DISTRE55 EXI5TIN6 FINISH. I N.I.G. 4. REMOVE ALL EXISTING COVERP TE5 AND DEVICES THAT ARE NOT DARK BROHN AND REPLACE. I no LA EXISTING "TEST" MILLWORK PA I j 6. EXISTING ILLWORK AT PHONE AREA O AIN. PREP TO RECEIVE Dl5TRE55ED FINISH. REMOVE EXIST. METAL END GAPS. l 1. OPEN I COUNTER AND OVERHEAD ROLLING SHUTTER DOOR. j O I q. REMOVE ALL 516NA6E AS IT OCCURS. 1 10. REMOVE EXISTIN6 SHUTTERS, HARDWARE, SHUTTER MILLWORK VALANCE AND BLI . COORDINATE EXTENT OF REMOVAL WITH DRAPERY INSTALLER. O I I U 12. REMOVE EXISTING DOORS 4 HARDWARE IN ORDER TO MODIFY PER ARCHITECTURAL PLAN I I J MEN'S 0 --- --------- -------------- ---,---------- - -------------- ------------ ----------- ----.-------_-.- ------------- 1 Tm W t0 F- J � o � � ( a 0 0 0 0 J co WO A LF REVISOM BY �- DASHED LINE W 0 DENOTES SCOPE W 1-4 oF WORK. Z N `�}}T 7_7 2 z uJ � N 1 2 5 4 q = O N 0Ic-0 o F t- Qt� O e ��Y 7l Y X� PREFUNGTION U LL WJL ❑ o W 30. 00 to 1 2 5 4 91 __ EL OR 0) N c N (� I II MEG IGAL N I. I Z N I2 12 r r r r A� STORAGE ROOM SHAFT N I STORAGE N.I.G. OAF 1 GE r ROOM N.1.c. SERV I GE N N.I.G. 11 r 1i li , i' ii T n II rl { I —____ ❑ TYP. (1 6-2x-00 zo ri 2 I I \ / I STAIR #1 I \ / KITCHEN STORAGE N.I.c. II �// \\\ i .o ® GASGADE BALLROOM > I+----------------y O o -. 0) c 1 2 5 4 q �" ; O E z DISHWASHING � 0 O POT N.Lc. � � 0 � r WASH L Z m N.I.G. O NOT SHOWN THIS SIDE m m 0 ® NOTE: 0) BLANK PLATE cd 0 E QUAD OUTLET 4 (1) () .j MICROPHONE OUTLET - ALL 0 o 14 1/211 A.F.F. _ (1) BLANK PALTE QUAD F K W OUTLET 0 5"1 1/2" A.F.F. `1� r GHEI~i5 BCALE: 1/4" = II-0" 10 10 OFF I GE N.I.G. DRAWN: FB ® 51 T" off ly, ----- ----- '� ----- •� JOB # 915026-21 DATE 12-15-qq [�E I - I ® I T I O N FLAN 5GALE : 1/4" I '-a il 1 c yQ' t L L C-4332 i �U � SFa aR��� �-i-iF �� -r -t -�-� .�i i-i-] -+ -4 4 � � �- �-i-ice � -� �- �- �- �-i-i � +- � � + �- �- � i-� -4 � � +� -� -+ � 4- -i -4 -� 4 � � �- �i-i � � -� � � � �i- � � - � O o7T 1- i � e -i � TT ' - - - - - - + + -� �- ri-� -�� � fi �- r rig � t fi �r r i-i-� -t � t t- t- -i -r -t t t- t- r i-i-1 -t � t -r �- r ri � -r + -r �r r i -t t- t- r i�rH � 4it � -r -t't t � t- -� � -r t- r- rn 0 11 I I I_I_I I I I 1 I J � � tfitrri- - - t1-- -rt- �i-1 -� �r � rri-i-1rtrtrt � rri-i-1rt -rrt -rfir- i-i--l -r -rrt _- rri-i-1rtrtrt � rri-i� --rrtrt � rri-i7rt -rrtrfirr� -r -rT -rrri-� -r -r -rfirri-i -Irtrt -r -rr- rri � � L V T F I-I-I � Mort T T �" rl-1 � -t rt � fi r I�I�-���-I-�-�- -�-�-I-�� � - ,rt � �" 1-" r�� 17 T - - - - - � -��T - - - J Lei-i� �r ? T i 1� r[i i � TTTr� �i_i�i q � TTi� 7 I� LL L J 0 II o LLI_I I I I I LLrI_IJ � I I 1 I I I_1.�� � �� I I I � � I � L 1 Q l �L � 1� 4- 4- � � s � 4 � � �-i-i� -+ � + � �- �-i-i L - - - - - - - - - - - - - - - - - J + i=i� rt- r,1�Iui i r� icA D o � j�—I ft fi �-f 1- � � T 1- i .�II I I GOAT ROOM 5TOR,4GE ROOM FT — — � N � Q n 7 7 -r -r r ri�� r r- rim � rt & r � ���I—) -i�rt rt t fi 1- rl—I -I� t�fi' r I�I—I � -t rt � r j I^) J OFFICE SERVICE � U� i=i i i TTrFi i i i � r � Qn�7rtfir9�n �r � TOr � n�1 � 7oTT � � r�� �o TlL N.��. T 5 1gJ1 _I I_ I_ I ��_I1 _L1T I_ I I_I_I _I _I TT I_ I I I I I I I I I I_ 1-1-1 I I _I I TI I I_I � I � W —I -1 �. 11�LL �IJ _! -l. �- 1LLLIJ � 1 � � LLI_IJ� 111LLLI�JJJ_ 1lLLLIJ � 1 + aL.. J N — F[I � �j J N _ ❑ Z -H -f �I-I I-I � � t -r � 1-- I-I- fitt- �I- � t � i- �I-I � -ft - --i � � -H -f � �- T A I I� �I I I �� -I I T I O pFp N + �.11LL� + rr -� -+ � i-i � -r -r -r -rrri % rr- i-i-� rt �� i-� � rt -rrfiri-i � i-d � -rt � ri-i- ' �i i rn � a ��-� --� 7t�-rfi � � �rTTr � n-i � Tai-i-n Tn-n � 7TTr � -i � � TTr � � r� � 11LL LI 1 � � 11 � VJ � V L1- -� i i -r r ri—i — i iii i �=i i i T i i of i �—� �-I�d � 101 1 Ft 4 �- � � � � _ � _ _ _ _ � _ _ _ � .o �� � �_i i iii io _ iii i + + � � _I_IJ1TrFl_I � J_ 1LLLL1_I � 1 I LLLI�I_I � � _ L LI_IJJ � ILLL1_�_� � _ 1LLL �1� � � �. + }� � W I O f t -; 44 to 1+ + 3: 0 ii 1-1 -1 ���� �11�LLLCL_1_ �iI �i 1 -�2 tt i-F T T F I- �1-I - 7 T T - 1=1-1 -! -1 � T T FF1=1 - 77 T r �I� TTr � i 4- - I-I� -I 4 - -I -I - - - a- - I-I � ? i � I T� T� � Q �� � i i = + � - + 1-1 4 � � I _� � N STAIR #I I1LL J � 111°� _ J � t - 1-I-I � L�LI � 11L _I_ — 11 04 _L 11LL � �- - - a I I� � r - � ZII - 1L _1 � 11�� 17 fifirrrtt �-�� � +- � i-i-� � � +- � i � -r T r r �i 7171 -1 r 14_� _ 1� fi � �� � -111 rt t t— H-1-1 -i L-r 'rt' t� _ ti i I(�- �X1fI 1�-- � i-II-II -I f I I I�� � � 1--1-1 � a � � I-I-4 � - a- I-I �TTi- [I-I 1 - I I I I [I � fit �1-1 -I � fi � �l � � ttfi �I_I -1 �I1III I KITCHEN ��e BY 1JL � 111LLL1_I J � rtt �� � � �- � J- � I-I � T T_ 7 7 I-I 7 � ,�ADFBACC - 7 T T - F I-I 7 �+ +�i+- �- i- -4- 4- 4- � �-- i i E - � � -i-i-i-� -� t- - �- +LLLIJJ � 11LL1_IJ11lLLLl_IJ �; fiit- ri_i rt -rrtfifirri-� � � � �i_i � � � � �i_i�1 �. � � � �i_i � rt IT ��T- � I-I-I -�I � 7 T T T � �1-I � �- � �I-I-� -4 � J- I-I-f� -I� 4 4- 4- �I-1 � 7-T T 7 I-I-I-I-I-I-I'4n7-ri-r -ru I� �I-� `� � I TI fl-L L LI _ IJ 1 1 1 1 1 1 1 I_I_I II I LI_I_ 11LLLJJ � II � LLL fifi � rl-I ti- � �I-I -t � 1 _I_I_LIJJ �iL �I_ 11 ri �JJ - 14 4_1 � � � + i � 1LL1 I 1LLL1 fit- - -i - tt - i- -i -trt rtr� r-i �� - -�trttit IJ �TT �f�" 1- I- I7-1 -trtt �pt' rl-I-1rt7 � -I -T -Tt � fil-I rtrtTlrl-I- -fTT ❑ TTri 777T -FT- F- 1-17 -1 -1 i i i Tr � �i 77TFO_ 7 i T� 1LLLC� �IJ_I I �. � t � � �H -i � + � ti— I—I-1 � -t -+ � 1- � �-I-111 I I I I 1=1 I I I ,��LI_I_� � �L1J� I11LL1_� � � JJ �111LL1_U � � ttt- rl-I-I -t � tt� t-� I-I-I -1 �trtfi1- � rl-I �I_IJ � 1 .1_ L �I � 111 I-� a- � I- I-�-1 -f -1_1 � 11 � L L I_I� J � T T 7- r I-I� -1 -7 T T T f I-I -f -T -T T � r I-I-I � � -� 1 � L �I_I� ._J. 1 -�-1� I-I� � Z + + � �— ti— —i —�I� L-1-1 -fir �r I�'o������� ����� �—'�� � t'rI� }, � �trtfifir0-1 � 7T 7i_i_i � T � r � i_� 7 i TTDri_C i � rri i_� 77 � T �ri_i_i7 � rri—irtfit�- `p c� L I_I�I 1 1 1 1 1 1 I_I_I 1 1 1 1 1 1 � � � J � TTrr 21 � 111LLL I 11LLL1_I-1 LLLI_IJJ11 .L� IJJ _11LLL1- I 111LL71� T __ V T I I �� � � I-I-I -1 � i � �-- I-I-I -I � � i I-I -1 �- --1- � � � I-I �i I -I � �- -!- �- � �I �i � � I-I-I� � -1 i -r L 0 J 1L I L � �� -I- I- � ����-� 4- -1­- I-I-I �� � I-I-I � 4 � � � -I-I � 4 4- -I- � I- , -� 4 �- -I- I- �-�J L E LL cd 0 cd � p m 0 cd F UU � o v 'ao 'ad O w » U O DRAWN: AT E�E ��OLITION REFLEC/ TED C/ EILIN5 FLAN 1 SCALE: I/4" = I '_0" ,,oe . asoa�-�i REFLECTED GEILIN6 DEMOLITION NOTES: - I. REMOVE ALL CONGEALED SPLINE GEILIN65 AND SUSPENSION SYSTEMS. PATCH ALL AFFECTED AREA5. Z. REMOVE ALL RfiGE55Ep DOVAILI6H'f5, PREP TO RfiGIRGUIT AND INSTALL NE^I, IN NEW LOCATIONS PER REFLECTED GEILIN6 PLAN. SALVAGE DOMLI6HT5 WITHIN PRERMGTION FOR REINSTALLATION. CONSULT REFLECTED GEILIN6 PLAN FOR ADDITIONAL INFORMATION. DATE 12-15-99 3. REMOVE ALL SPEAKERS. EXISTING TO BE REINSTALLED AT SAME LOCATION IN IOW CEILING. 4. REMOVE SMOKE DETECTORS AND REINSTALL IN NEW CEILING IN SAME LOCATION. S. REMOVE ALL FIRE/LIFE SAFETY SPEAKERS E STROBES AND REINSTALL IN NEW CEILING IN SAME LOCATION. b. ALL SPRINKLER HEADS TO BE REINSTALLED IN IOW CEILING AT SAME HE16HT5 AND LOCATIONS. 7. E EXIT I FOR REINSTALLATION IN SAME LOCATION. TI & I ES TO REMAIN. ALVPSE FOR REINSTALLATION IN SAME LOCATION NN.OJ MB"6F7eNDEka 10. REMOVE ALL DOVE MIW^IORK TRIM THROUHFIaJf. PATCH AFFECTED AREAS AS REGJIRED. DRC = l II. REMOVE AND DISCARD ALL EXI5TIN6 TRACK FIXTURES. � 12. REMOVE ALL COVE LIGHTING. i vr� FOR REirgrAUanoN. 4. HVAG 6RIL A B LROOM COVES TO REMAIN. Rr.1DF��QJ �J z C-4392 DASFW LINE DENOTES EXTENT OF 5I of WOW n SED AR��\��� VVE:)ICA7ED DEDICATED I q>—1 �} � 6 N RIUEHMJT � rl2 � 1 12 16 � w EL-4 L PREPUHGTION 5 � (p s �. n�a�our ���4 EL OR �JJ �p I 3 4 12 18 O 21 � DATA a 4 � W L � J � i 2 raw AN STORAGE STORA ROOM � 5 FT� � N � a DATA EL-2 MAC ROOM NIG OFFICE J U� 10 BLANK �0 N.I.G. SERVICE � O l� FLA s� is �a DATA T D >1 � N J tG 0 o Z - N r II NEW DIMMER CONTROL � T BP � O � � r LOCATION. MATCH HEIGHT N XI5TIN6 5WITG T N LL REMOVE SWITCH PLATE REMOVE PHONE I N 4 0 MAKE BF MAKE BP � �fJ J O N 3 i Q �p N Z � N II \ STAIR #I II L L= N EXISTING BP'S � II TO BE MADE POWERADATA BOX � MIKE �I / \ � �V�NS BY =0 KITCHEN 6-2q-oo Zo 5TORA6P 2 GASGADP BALLROOM NIG SP MIKE i 2 s 6 is n ie o si TI THROUSHOUT �J-' DISITYVA5HIN6 eP � POT N.i.c. WASH N.I.G. PHONE OUTLET TO � TO BE MADE 8P� ❑ 26 N N � Q Q � EL-1 A D D M ' 26 ARC+iTEcnRZAL ram ADDITIONAL I. DI5TRE5R�INI5F A LL EXI5TIN6 MILLWORK PANELS TO MATCH TAE �ROU6HOUT THE MASTER 7YP, PHONE OUTLET MICROPHONE OUTLET I L 16 TO BE MADE BP �b �� TO BE MADE BP �b � 2. I T IOW G DI A T T I 5P AT BALLROOM ONLY. GON5IH.T ELEVATIONS FOR ADDITIONAL INFORMATION AND LOCATIONS. 0) N N N 0 5,_ 1 „ N 4. INSTALL 7 � IOW OWeR SUPPI_IED CARPET BORDHZPAD AT PREWNGTION AREA. O E IL t� 5. INSTALL W OV1 ft SUPPLIED CARPET SORDER/FIWINSEUPAD AT SALEROOM. b. INSTALL IOW ONNER SUPPLIED SCONCE AT OLD SCONCE LOCATIONS THROV6HOUf. -v O J 7. INSTALL NEK BASE FEI6HT STEEL GORNEREUARD5 AT ALL CORNERS TO MATCH EXISTING 70 p THROUfaHOUT LOBBYJRIBLIG SPACE. a: 8. OPEN 9. INSTALL NEW INFIU. WALL LOCATIONS WHERE SHUTTER NIPS REMOVED, MATCH EXI5TIN6 0) � m U CONSTRUCTION. 10. EXISTING 50LID GORE MILLWORK DOORS AT ENTRY TO SALEROOM TO RECEIVE (OWJER I _ U .$ w PROVIDED, 6G. INSTALLED) NEW DECORATIVE TWISTED STEEL TO MATCH ENTRY DOORS. ADD V C NBV MILI.INORK GA51N6 AND DARKEhW NATURAL 512" WIDE 0--CHANNEL DOOR ?,RAP 70 COVER DOOR IMPERfEGTI0N5. PAINT EXISTING HM FRANCS AND INSTALL NEW HARDWARE A5 SPECIFIED. SAND, REFINISH i Df5TRE55 TO MATCH NEW MULL FINISH. •Qf •� ld � II. EXI5TIN6 PHONE SHELVES i CABINETRY TO BE 0I5TRE55ED t REFINISHED TO MATCH NEYV ' > V Q HALL FINISH. G I I IG 7ED ON THE DRAWINGS. ALL � EX 5TIN6 ICES TO REMAIN. 14. OPEN BCAI.I I/411 , 11-0" 15. OPEN C � I !� C ����� PLAN I6. COORDINATE NEW OVER SUPPLIED AND INSTALLED WINDOW COVERING A7 WINDOMI DRAWN AT III G T G INFORMATION. PROVIDFJINSTALL NEW DEVICES AS DENOTED ON DRAWINGS. 5(�ALE: I = l '—O I� 19. FAINT PROVIDE NEW'DTIARKEI� PlA'NRAL 5 GORNER6UARD5 I 15N ZC� TO MATCH EYJ5TIN6. �� � a��-21 20. PREPARE All HOLLOW METAL DOOR PRANGS, METAL HVAG LAVERS, ETC. TO RECEIVE NEYV PAINT FINISH AS SPECIFIED. 21. INSTAL.I. NEYV BROWN GOVERPLATES AND DEVICES AT ALL NON-UNIFORM LOCATIONS. 22. REMOVE EXf5TIN6 MILLWORK "TEST PANELS" AND PREPARE/REFINISH MIU.NbRK BENEATH TO NEH DISTRESSED FINISH. DATE 12-IS-94 EXISTING YyAI.L A55"LY/REPLAGE MILLWORK PANEL TO MATGk EXISTING AND NEW DISTRESSED FINISH. 25. PROVIDE NEW BLANK-PLATE AT EXISTING 5GONGE LOCATION IGA TO IOW ELECTRICAL/A\/ BANK. SEE r:LEVA7ION5 i DETAILS FOR ADDITIONPI. INFORMATION. I A - 1 ........... ..................................................''I.............................. ...................... GYP. 5D. GEILIN65/50FFIT ��' it PT- ' ,��FACES � �.� I w,r I HVAC G ERILL5 THROUGHOUT DASHED LINE C43W. PTA ® GEILIN65 4 SOFFITS (TYP) < of wo",c. ED A � ---- r i ® 9'-O" O O o�, ON' o� O ® Dow 000.) ® o�' ONQ O O`er o�' ® � �FF ® O O ® OD O ® ® O TYP. THROU6HOUT ❑ Q 1 2 6 1 4 TYR THROUGHOUT ® 1 2 5 b q 2 -1 II 12 II la ® O O � 12'—O" A.Q.F. FD O lo'-o" A.f.i. 2 U OMQ O� O� 0 3 Dow EL oR J .I.c. � Q o o Q MEG I GAL Cp A/V STORA6E STORAGE s �T 0 � ® Roots oFF I cE Roots W �D � SERVICE ® J Oow O� O � O Oaw SP Oo O Oow O� N.I.G. o � 0a 1 �' N I J co ~ — � Wow ❑ WZW) 48 O� ® � -- N ® Z ® o O O ® 0 C4 00 0 O o = o CV co � N coU 4 6 `� I I � w EP ® 0 o STAIR #I o 0 0 0 0 0 0 0 0 0 0 � N I I Lf) (> N 0 a s N Z I 8 � � I to • N N ® ® &-8 I/2" APP, O I o ® C4) 6 I ® O I 07 I I Q Q O I I KITCHEN STORAGE I N.I.G. cASGADE BALLROOM Q O D O O I O REV118I0NS BY I 3 - I I I a Q I I '_ A. �i -'" A.P.F. 10 � APP. 0 A.P D 15HAA5H I N6 ® ® POT N.I.G. O ® I I O I Q WA5H O N.I.G. Q 0 0 ® o o Q o 0 O o Q o I I THROUGHOUT ® ® c ® .o Q O OO O Q Q Q Q O }' 'o Q L c J 0 o.. 0 a� c� ° J J w L J U co D 6"1 50. GEILIN65/ 0FFIT O m PT 2 FACES 5 � U � v HVAG 6RILLE5 THRO06HOUT cd W J PT ® GEILIN65 4 50FF1T5 (TYP) U. cd cd o W SCALES 1/411 REFLECJEI� CEILING DRAWN ,4T Cj)-5 —,o,ALE : I4 li � III JOB 0 Q5026-21 REFLECTED GEILIN6 NOTES N5TALL NEW GYPSUM ARD G L IN WIT 5 00 F N I T ROU UT. SUPPLY GYP. BOARD CONGEALED ACCE55 PANELS AT ALL MECHANICAL/VALVE LOCATIONS FOR ACCESS. ALLOW FOR (14) 2X2 TOTAL. COORDINATE W/HOTEL. TUV10E AND iN5TALL DOWNLI6HTS AS SPECIFIED THROUGHOUT (U.N.0). CONSULT A55 DRAWIN65 FOR CIRCUITING/ZONE5/5WITGHIN6 DIMMING SPECS., ETC. DATE 12-15-111 I W TALL NEW MILLWORK COVE MOULDING THROUGHOUT COVE. SEE FD L G F ! 5 A5 SPECIFIED. AL LOCATIONS INDICATED. E 15TINO 51 IN X TI 6 LOGATIO 5 GA *VA6i lo 11 11 - A55 DRAWIN65 FOR ADDITIONAL INFORMATION. 4LL SPRINKLER HEADS TO REMAIN IN EXISTING LOCATIONS IN NEW CEILING. 1 f&INSTALL EX15TIN6 50REEN PROJECTION IN BALLROOM IN LOCATION SHOWN. INSTALL AL IN H 6 iL 5 N 15 LOCATIONS. WIPE GL� R TO IN AT ON R 0 NS AL ATI N F P D. G LI 6 NG ON, LY Y A LIED FI 0 I N6 A5 SPECIFIED. Rc I rif cot cQ �So A1VpF� A r....................''I................I'll,............... C" C-4382 1YP. - 6YF.BD.C�EILIN660PMT FACE � O ------------- ------- SCONCE - ySFD ARG W.CEiLIN6150F9T FAGS OWNER 9IJPPLI®A�b owe suPPLlen AND I TALLED DRAPERY INSTALL® ORAMW I Ot" .� EXI9Tro FETAL REVEAL U TO BE RBA • GOFPLEILY. �,■,� �YPIGAL-Tf'RauBFlouTf � O O o a o � EXI5TIN5 DOM ui w r O CD 0a w co w0LO Cn — N = N MOM F -° MOM ANA=nV O �' N +NAG COVER MAIM T REAIN MIM)) OD 0 ELEVATION a CA56ADE BALLROOM a cri VZ=I'-W ULL co -- w = Uo 8 cq N(d N Z N N F) FAA DOOR R IHIARPWAlE: NEW aqm SUPPLI® V.IF,EXACT NUMBER OF pr-2 ®YI°•W.CLILI ISSOMT FACE SGONGE-TYp. I:XISTIN6 FAM& FM t'IQA1rE TYp. FDa pT 2 &M-BD.G8LIN ADIMIT FACE REVISIONS BY r-ASTIN5 FETAL REVEAL TO BE REMOVED - / COMPLETLY. / \ �TYP1CiAL-1�ROIJ6hI0UT) S `\ O O I C ELEVATION @ CA50ADE BALLROOM � o_ o o V � rr'rr -I DARI�D NATLNiAL 5TEEL � � •f+ DD NATURAL STEEL DOOR mw TYp. C) O 'I pr--� e1'p.CkILIN6/SOFFIT FACE NM MM SUPPLIED V.I.F.EXACT MMM OF NNI mtve � � w EMT.DOOR 4 Nil PANIC DEVICES +E-rn°• EXISTING FAMA W/NEI HOLD OPEN FIA MARE FIiAiN5 �• L at" � U ,o ■ ■ TM6 METAL REVEAL. TOBE RNM / \ GOMPI.ETLY. SCALE: 1/2°=11-0 it DRAWN: ZO JOB # 143026-21 O O / -- - _- - - \ / \ / —7Z DATE 12-15-qQ \ / , Fi=I NEW IBASE ITT RETURN w FRAME ON ITSELF•DOOR d' J 3 ELEVATION ® CA5GADE BALLROOM SCALE. 1/2-1-1 ELml JL- y �a a ir PROVIDE BLAND COVMWLATE AT MTINS SCONCE LOCATION. 5EE RF PLANS i IV V.I.F.EXACT NJFM OF NEI OILER SUPPED DETAILS FOR CAVE INSTV PAN". 9CO E 1IFORl4ATION TV. P,I, i9YP.BD.CELIN A SOFFIT FACES. lop =Ri—i GROWd 0 U PT HM M AME — DOSTING METAL O / \ r r..... .....—————— -- —I REVEAL TO BE �' 0 Q mYP THROI ir) W YP / \ I I T .I'JLANC PLATE IN UXV W ❑ / \ I OF THE STIMg.ONE Y E (Q J\ ! I co ( Q J ~ co W O Ln -------------- --� I W IcA9TTNO HAFZK4 E• / , I N DOOR TO BE REUSED. 1 1 c J N E// Z KIUC PLATE EXISTINS METAL 0 N R80GATE ARTWORK FROM I REVEAL TO BE r PIiE1 MTION I~NIRY WALL. . co trYPlurL-THROI�8I�OU'I') r Q LL I EL.EVATION @ GASGADE BALLROOM co � SGAI I/Z=I'-0" W = 0 W 3: U 8 N N N Z N cq _ F DARKENED NATURAL STEM.DOOR V.IF.EXACT NJI M OF ( ®(TV) PT WIN.W.CEILIN6/50FFIT FACE WRAP(m) EXISTING PA M& - TYf. DARKOW NATURAL 5TML DOOR EXIST.6Tl W DOORS ie Be cROr�l-TYP. I REVISIONS BY cMN6 ON EXIST.> O 6-2M-00 ZO E?p9TINO METAL \ / \ REVEM.TO RatovED \ (`TYPICAL-T+N�oc�FIOIlt) 'TEST PANS"LOCATION ,a METAL \—NIDARK?IMTW NATURAL STILL.PULLS TO MATCH SRE M TO BE HOM ENTRY PILLS.CONTRACTOR TO VMPY TMT SZE OF F04OVw C04PLETLY. '}~ I I NEI PULL COVERS EXIT.HARDWW HOLES i AP T,rAZE OF ,�,-A. ELEVATION ® PRE F U I C T I 0 I B�KrKPLATE A8 IE�UN�7.HOTS.PROVIDE?-6G INSTALLS A 2 90ALE- I/2=1'-0' a. L � o 0 0 0 � 0L co 1 m .2 Cd 61fP. W.CEILINSWITIT FACE /) ; o -0 V 0 w �_ _7 / C ToA +MMTo iN9ET. > > > C E05TTND AN=nV BRONZE HNDOW FRAME sTOR�T ( WA-E: 1/211=11-011 TO EXI9TIN6 METAL '� ST'INS METAL DRAWN: ao REVEAL TO BE REVEAI.TO BE mff40VED COMPLETLY. REMOVE?COMPLETLY. h�rPIGAL-TNRaJ6FI01tr) "C L TNROUSF m) JOB * 43026-21 EXISTING hYNGOW i BILL / 3 � VTION CA5CADE BALLROOM L--- --j SGAl,E1 Ili=I'-0' ELm2 A ,`4 P aN 9svy .4382 C� i SED AR I I GYP-BD.GEILINDAOMT FAGS ANODIZED WINDOW Np. PR► WTOREFRONT TO REMAIN J / I I / —21ill 0 0 y W � Doi ro/ 7F 11 1 r r w cn co n in nI n mi Q F +_ - VII■ w 0 � ZN t Z F � = Qcv co LjL r Q � ELEVATION a PREFUNGTION / CORRIDOR U 3GAE.E� UZ■I�-0' co � w � = o UJ U 8 I C4 N co-� N ern.W.GEil.INOMOMIT PAGE Z N CV Mr MOTINO METAL REVEAL Q TO BE REMOVED coM�.ET�.Y. I cMIGU-T�IRar�lolrrl TIM V.I F.EXACT oP EXI5TM FANM. A NWZ®WHM I M. Fi WAMW TOFe%M TO REMAIN IN BY 6-v-w ZO I / / / / I I / 0 / / / / / / / y T Dg5TlN6TO METAL FWVVL BE REMOM ELE\/ATION a PREFUNOTION / CORRIDOR 2 SCALE, 1/24-0' � c o � m E . a:a� 0 o p L m m ,a cd U m 0 o U w () UAL F U •O 8 moo L Cd cd ■■r■r � C SVA■ r.- 14211 C 1 1'0 11 DRAWN: zo JOB # g5026-21 DATE 12-15-gq EL = 3 Of cat 0 c ` O o A1�D��� � vZ C-4382 . Pr W.GEIUNG 4 EXIST.DOOR 1 SOMITS HARP AM V.IF.EXAGT NIII+BEii OF EXI5TIN6 PANE A I TYP. 3'M FRAMES. Tom. V.I?.EXACT Mmm OF -7\ EXI5T�NS PAMEL5. ■ TYP. CA "w o c� EXI5TIN6 METAL leVEAL TO BE ell MOM / GOM�I.ETLY. O a W W Zoo g _ Q � D O ca (0 - co w o � � � zN � � JN OD 0MT I VARKM NATURAL 5MEL RM T a ELEVATION a BALLROOM PREFUNGTION CORRIDOR U LL =r-a W = o Wv 3: o N N CV) t0 N Z N N r V.I.F.EXACT NUMBER OF 6YP.W.GEILIN5 4 6'rP.W.GEILIN6 44 EXI5TIM6 PAHM. WMAM TYP. t REVISIONS BY 6-2q-00 ZO DMIN6 METAL REVEAL. NEW SGOWA 5 PROVIDE? TO BE RD40M EXISTTM6 H= BY OI"NER 6G INSTALLED. f "IGAL-Ti as"IDUT) PANELdWMM Oft GORMtIDOR TO MAIN LOBBY O t C � o E?05TTN6 HMP r PANEJNWIRIM v C EXIST IM Dom 1 MIIiW w WILL IfARDWAIRE PANEL ELEVATION 0 BALLROOM PREFUNGTION CORRIDOR ELEVATION ® BALLROOM PREFUNGTION CL a 2 SCALE: I/2■I'-O' 3 SCALD Ln■I'-O. L C 0 0 0 Im 0 43 0 ` In v 0 � � ad 0 0 Lu w U •_ ■ ■ r rrr ZCM0 SCALE: 1/2"=1'-0" DRAWN zo JOB # "026-21 DATE 12-15-QQ ELm4I COg p'�q C-4382 CORRIDOR FIELD CPT-4 ysEp ARC��� CPT=5 PAID THZOUC HOOT U r J J o 4 0 0 .� 0 a w � ______ ________ W F- o J � 0 CO -w-\- r I Tm J r. — w 0 L wZU) -" N GORRI DOR FIELD (!� J N C P T�� GPT G�'T Z CPT-4 N CORRIDOR FIELD PREFUNGT I ON 0 N CPT-5 5QA�RDER F. V. �o (� CPT-4 PAID Q LL CPT'%50 THROUGHOUT �JTORA�C7 U PAD � w ��_��, ._Q. (NIG) o�� G S�RV I G� C. NIG L o THROUGHOUT -, � U o W (Nl � ) (N I G) CD N N ' o c N HF Z N N o t� m ! I LINE DENOTES EXTENT OF 5G0FE OF AORK. ~ EXISTING ARGH A7 THIS L.00A 71 ON TO REMA X REVISIONS BY L 6-2q-00 ZO cl BALLROOM FIELD w, . CPT-1 GPT=5 PAID THROUSHOUT Reyes ed slab Storage (NIG) PT-1 CPT-2 HOLLON METAL DOOR FRAMF-5 , BALLROOM NALL MOUNTED HVAG GOVER5 7HROU6HOU7 �ORD�R _fG I TGH�N (NIG) i P07 O 5H m 0 Open tobl p w, o o E -0 o "0 ad o ad tu 00 m 31_011 PT.1 3'-0" - _\ 0 V c HVAG METAL COVERS (TYP.) - 00 cd E t n () L W C) > > 0 L m SCALE: DN5 DRAWN: ZO JOB * 015026-21 NOTE: HOLLOA METAL DOOR FRAMF-5 , NALL MOUNTED HVAG COVERS THROUC HOUT DATE 12-15-4q ASC,-�, AL E 5ALLRO /FREF NCj7lCN FINISH FLAN DO NOT SCALE IFml yof arooF9 qpo ir pass2 F-60 Fm6OO F'60 F=600 F-60 F-60 F-60 F-30 Wm:3:0 BF-101 F-40 F-30 F TMP. ,-rP. Q O U 0 Elk UJ J � o � � JN i Z J N 0 clx—) E V. co VLL V O G0,4T RM, STORAGE OAF I E SERV I G� 8 UJ (N I G) (N I G) (NIC) G I G,4L O C) N N Z N Q N H a&'VI1SoM BY Q 0 5talr 301 Race s d slab 03F=401 NP. St�o,Irage F-60 (IVIG) ■ w6O ■ KITCHEN F-60 (NIG) Li L F-30 05H � rYOF. 0 �0 E a Open to blw. U O cd � F soi ca V � t GHE� 'S V v °D OFPIG� > U IL SCALES DN5 DRAWN ZO JOB t F3026-21 DATE 12-15-94 ASC.,...., ADE 15ALLRO /FREF NC.:,, 71ON F RN SHING FLAN (D DO NOT SCALE FFEm1 CO�p 10 AND co r,-A3'82 USED AEG PT. METAL CHANDELIER TTOP. tr _ o • - U sP ® O'-O AF, AN a 101 1 1 1 10 �lrj I C) I =J 0 � ❑ O EXHAUST TYP. J 4 ❑ -- ( J J � 0 co (0 o EL OR � w 0 0 0 0 Wog MEG I GAEL �jJ Z � GOAT ROOM STORArGE 5 ET N I 1—z I OFFICE ROOM t0 O ® � o o N.1.G. N.1.G. Z N o � w ` 0 0 � ® o a~oU � / r Q � LL � U cq T W _ Uo Cfi W cv ® o FF 6 5 rt k! r / _+ (� (d I ® A r - - - -- -- -- -- - - Z N c r _+ � I I � r I I 5TA�IR #1 - I I ® ® REVISIONS BY ® r RECESS FOR T. "WjEGTION SCREEN I KITCHEN I I I I I I sr I I I I / JO r A ® 10' 40 01 L - - -- - - -- - - J I V-81/2„ z I L - - -•-- -- - ,.,. ...- - - - - - - - 1 o I o o U ° u,. 1'xl' ACOUSTICAL CEILINS TILE cd cd 0 X TYP. W NOTE: CONTINUOUS TRACK AT WINDOW SIDE SUPPORTINS SHUTTERS TYP. SCALE: 1/411 = 1'-0" DRAWN.- AT JOB * 015026-21 DATE 12-15-4101 EXIS71NO REFLEG7EE� GELIN5 FLAN F- F— SCALE 114 � 1 '_0 �� ERC = l WING0ONgULTANT • 1 123 A PARKWAY, 400 REoT INATN LIGHT 1MMICA CNTUTN SFWIFIATI DENVER, COLORADO 80204 EL�GTRI GAL LAC END 303-623-6200 FAX 623-8435 ® EXIT SIGN-SHADED INDICATES FACE I. THE CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIAL NECESSARY FOR A 20, WIRE NO.S AND SMALLER FOR USE IN INTERIOR DRY LOCATIONS SHALL BE TYPE NOTES ALL ITEMS MAY NOT APPEAR ON DRAMNSS COMPLETE AND FUNCTIONING,ELECTRICAL SYSTEM. TAN THERMOPLASTIC 600 VOLT INSULATED COPPER CONDUCTORS. FEEDERS FIRE STROBE AND POKER WIRING NO.6 OR LARGER SHALL BE TYPE THWN 600 VOLT INSULATED 2. MATERIALS AND INSTALLATION SHALL COMPLY WITH CODES,LAWS AND ORDINANCES COPPER. WIRE WHICH IS INSTALLED IN RACEWAYS IN MOIST OR DAMP LOCATIONS GROUNDED SWITCHED DUPLEX RECEP'TAGLE FIRE HORN OR SPEAKER WITH STROBE OF FEDERAL,STATE AND LOCAL GOVERNING BODIES HAVING JURISDICTION. SHALL BE TYPE XHHW,600 VOLT INSULATED COPPER CONDUCTORS. NO WIRE SMALLER THAN NO. 12 AWd SHALL BE USED FOR LIGHTING,OR POWER WIRING. WIRE NOUS LARGER GROUNDED SPLIT-WIRED RECEPTACLE PORCELAIN LAW HOLDER 3. �TRACTOR SHALL PROVIDE ANY ADDITIONAL MATERIAL RELWRID TO COMPLETE THE SHALL BE STRANDED. GROUNM DUPLEX REGEPTAGLF l^l 21. ALL NEW CIRCUIT BREAKERS FOR NEW OR EXISTINS PANELBOARDS SHALL MATCH 4. CONTRACTOR SHALL ENSURE ORIGINAL CIRCUIT INTEGRITY 15 MAINTAINED W1�REVER EXISTING,19UILDINS PAN LBOARID MANUFACTURER AND BREAKER TYPE. THE -LINEAR TRAGIC A DEVICE IS REMIOVED,RELOCATED OR RECiRCUITED. ORIGINAL CIRCUIT INTEGRITY CONTRACTOR SHALL PROVIDE NEW TYPE WRITTEN PANEL DIRECTORIES FOR ALL PANELS O SHALL BE MAINTAINED BOTH UP AND DOW9d STREAM OF THE DEVICE. GH ANIOED, INIGLUDIN6 AVAILABLE SPARES AND SIZES OF SUCH. i SPEGUIL MU OSE RECEPTACLE © WALL SCONCE 5. CONTRACTOR SHALL REMOVE ALL DEENER9IZED OR UN UISED CIRCUIT WIRIN3 UNLESS 22. EACH SWYTCH,LIGHT,RECEPTACLE AND OTHER MISCELLANEOUS DEVICE SHALL BE ® INDICATED OTHERMSE ON PLANS. PROVIDED WITH A®AL-VANIZED OR SHERARDIZEERD PRESSED STEEL BACGBOX. ALL SUCH FLOOR MOUNTED RECEPTACLE J� DEVICES SHALL BE SPECIFICATION GRADE.CONDUITS SHALL BE FASTENED WITH • •-Q WALL SCONCE 6. MATERIALS AND EQUIPMENT SHALL BE LISTED AND/OR LABELED BY UL.ETC.OR LOGKN UT'S AND BUSHINGS AND ALL UNUSED KNOCKOUTS MUST BE LEFT SEALED. FLOOR MOUNTED DATA OLUTI,.ET ANOTHER RECOGNIZED TEESTINS LAB. THERE MUST BE SUFFICIENT ROOM FOR WIRES AID BUSHINGS AND DEEP BOXES SHALL BE INSTALLED J WALL SCONCE 7. THE CONTRACTOR,'HALL AND PAY FOR ALL PERMITS,GOVERNMENTAL FEES, ���R� YdaE7iE REQUIRED. BOXES SHALL BE SECURELY AND ADEQUATELY � Q FLOOR MOUNTED TELEPHONE OAT TAXES AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF CEILING FIXTUft THE ELECTRICAL WORK. 23. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SPECIAL OUTLET BOXES THAT MAY BE © DATA OUTLET REWIRED TO ENCLOSE RECEPTACLES. (� b. THE CONTRACTOR SHALL NOTIFY THE ARGHITEGT/ENGINEER/OWNER OF ANY MATERIALS /� V TELEPHOtWATA OUTLET Y OR APPARATUS BELIEVED TO HE INADEMATE,UNSUITABLE, IN VIOLATION OF LAWS, 24. IN SUSPENDED GEILINISS SUPPORT CONDUIT AND JUNCTION BOXES DIRECT FROM THE w Lam(:]/] ��STRIPL&ff ORDINANCES,RULES OR REGULATIONS OF AUTHORITIES HAVING,JURISDICTION. STRUCTURAL SLAB,DECK,OR FRAMING, PROVIDED FOR THAT PURPOSE. BRANCH U T TELEPHONE OUTLET CONTRACT CIR1 CIRCUIT CONDUT5 SHALL NOT BE CLIPPED TO THE CEILING,SUPPORT WIRES OR SPLINE, n Q. THE CONTRACTOR SHALL CAREFULLY EXAMINE THE CONTRACT DOCUMENTS,VISIT THE ((� .,O •T1ON BOX BATTERY PACK EMERf3ENGY LIGHT LOCAL AND THOROUGHLY BECOME FAMILIAR WITH THE BUILDING STANDARDS AND 25. CONTRACTOR SHALL COORDINATE WITH MECHANICAL AND PLUMBING DRAWINGS,AND LOCAL CONDITIONS RELATING TO THE WORK. FAILURE TO DO SO WILL NOT RELIEVE THE INFORM ARGHITEGTSIENIGINEER OF ANY CONFLICTS. J K&L MOUNTED.IUNGTION BOX CONTRACTOR OF THE OBLIGATIONS OF THE CONTRACT. II SINGLE POLE SWITCH 26. THE CONTRACTOR SHALL PREPARE THE DOC.IUMIENTS, INCLUDING,DRAWINGS,REWIRED W � J 10. THE CONTRACTOR SHALL PROVIDE TEMPORARY POWER AND CURING FOR THE TO OBTAIN APPROVAL OF THE EQUIPMENT AND LOCATIONS OF THE DEVICES THAT OJ ESIUIPME DISCONNECT SWTCH $0 DIMMER SWITCH OF ALL TRADES FOR TI-E ENTIRE PERIOD OF CONLSTRUGTION AND SHALL COMPRISE THE WILD OW FIRE ALARM LIFE SAFETY SYSTEMS. A COPY OF THE PRAHIN SS REMOVE ALL TEMPORARY WIRING,AT THE COMPLETION OF CONSTRUCTION. AND GUT SHEETS SHALL BE PROVIDED TO THE ENGINEERS FOR REVIEW AND APPROVAL. Ld �- Oj EWIFV W FUSED l2ft0fEGT SNITCH THE APPROVED DRAWINGS WILL BE STAMPED,SIGNED AND RETURNED BY E.G. TO O5 SPEAKER-PAGING AND OR SOUND SYSTEM 11. THE EXISTING, POWER,516NAL AND COMMUNICATION SYSTEMS ARE TO REMAIN IN SUBMIT TO THE BUILDING DEPARTMENT. $TO THERMAL OVERLOAD 94TC4 SERVICE TO PROVIDE FOR THE ONCRS FUNCTION. SHOULD IT BECOM NECESSARY I � O TO SHUT-DOWN ANY SYSTEM OR PORTION OF A SYSTEM,APPROVAL IN WRITING MUST 71. SUBMIT(3)COPIES OF THE FOLLOWING,SHOP DRAWINGS FOR REVIEW. J LG ELEGTRlGAL DANIEL BOARD BE OBTAINED FROM THE OWINER AND SHALL ONLY FOR THE PERIOD AND TINS AGREED E ELEGTRIG WATER COOLER UPON. THE BID IS TO INCLUDE THE COST OF ANY TEMPORARY WLRINS AND PREMIUM A. LIOWIN6 FIXTURES AND LAMP' I t1 TIME REWIRED FOR THE SFUTDOWPI. B. DIMMING EQUIPMENT ®TELEPHONE 7ERMMAL BOARD f3= EXHAUST FAN G. WIRING DEVICES ' n 12. ALL MATERIALS,AND EQUIPMENT SHALL BE ERECTED, INSTALLED,CONNECTED, D. FIRE RATED POKE-THRV FITTINGS AND SURFACE TYPE FLOOR BOXES L1 1 TRANSFORh'ER GLEANED,ADJUSTED, TESTED,CONDITIONED,AND PLACED IN SERVICE IN ACCORDANCE E. DISTRIBUTION EQUIPMENT 1 t GFI 6ROUND FAULT INTERRUPTING WITH THE MANUFACTURERS DIRECTIONS AND RECOMMENDATIONS. THIS INCLUDES F. PROVIDE 'AS-BUILT"DRAWINGS AND SUBMIT TO ARCHITECTS/DESI6NER. w Ln HOMERUN TO PANEL-ARROM GGT GIRL1iAT ANY EXISTING MATERIALS OR EQUIPMENT THAT IS USED. G. FIRE ALARM SHOP DRAWINGS IF REQUIRED BY LOCAL JURISDICTION. O N IM76ATE5!UMBER OF GIROATS 13. ALL GUTTING,,DRILLING AND PATGHINN3 OF MASONRY, STEEL OR IRON WORK BEL.ON6ING, 28. WHERE FLOOR FITT1Nt95 REQUIRE PENETRATION OF THE FLOOR SLAB, THEY SHALL BE TO THE BUILDING SHALL BE DONE BY THI5 CONTRACTOR IN ORDER THAT THIS WORK STANDARD DEVICE LISTED BY UL FOR THE PUFUD05E AND HAVE A UL FIRE RATIN19 EQUAL • FIFES ALARM PANEL EG ELECTRICAL CONTRACTOR MAY BE PROPERLY INSTALLED, BUT UNDER NO CONDITIONS MAY STRUCTURAL WORK TO THE FLOOR RAT1NS. / AG ABOVE COUNTER-VERIFY F66HT BE CUT,EXCEPT AT THE DIRECTION OF THE ARCHITECT,DE516NER OR THEIR - `LJ © FIRE ALARM REMOTE ANNUNIGATOR REPRESENTATIVE. 24. CONTRACTOR SHALL WIRE TO,SET AND CONNECT ALL MOTORS, CONTROLS AND PANEL W=OTHER EQUIPMENT. FINAL CONNECTIONS TO MOTORS SHALL BE MADE WITH LIQUID TIGHT ( fl 14. PROVIDE "A5-BUILT" DRAWINGS AND SUBMIT TO OWNER. FLEXIBLE STEEL CONDUIT, 1/2' MINIMUM. VV // - 1 MANUAL PULL STATION TTB TELEPHONE TERMINAL BOARD 15, ALL MATERIALS,EQUIPMENT WIRING,DEVICES,ETC, SHALL BE NEW,UNLESS 30. NUMBERED CIRCUITS AND RACEWAY ROUTINGS ARE FOR GONVENIENGE OF DE51614 SPECIFICALLY INDICATED AS EXISTING TO BE REUSED. ONLY. ACTUAL FIELD CONDITIONS WILL VARY. INDIGATE THE CIRCUIT NUMBER USED T °g SMOKE DETECTOR AFF ABOVE FINISH FLOOR ON THE "A5-BUILT' DRAWINGS. y •► N 16, EXCEPT AS NOTED OTHERWISE ALL WORK REQUIRED FOR THE INSTALLATION AS SHOWN FIRE ALARM HORN I! LIGHT UON UNLESS OTHERWISE NOTED ON DRAWINGS INGLUDIN5 LABOR, EODUIPMENT AND MATERIALS SHALL BE IN STRICT 31. 64w. SHALL INCLUDE IN HIS COST THE REMOVAL OF ALL E:XISTINU9 ELECTRICAL DEVICES, O COMPLIANCE WITH THE BUILDING,STANDARDS. CONDUITS,FIXTURES AND EQUIPMENTS, DISCARD ALL EQUIPMENT AS REQUIRED C-4. O ' ® CEILING MOUNTED HORN E EXISTING, TO REMAIN 5HALL BE RESPONSIBLE FOR DISCONNECTS PRIMARY SERVICE AND TEMPORARY POWER. V 17. ELECTRICAL METALLIC TUBIENk9(EMT) SHALL 13E USED FOR ALL WALL OUTLET'S RUNININIE3 �- MASTER DIMMER CONTROL DEVICE IN PARTITIONS,BELOW RAISED FLOOR OR ABOVE CEILINGS. E=MT SHALL BE USED FOR 52. ALL ELECTRICAL DEVICES SHALL MEET ADA GODS REQUIREMENT5. (W EXI5TIN6 TO BE RELOCATED TELEPHONE OR DATA GABLES RUNNING IN PARTITIONS. PLENUM RATED TELEPHONE AND I , ® FIRE ALARM SPEAKER EX EXI5TINI5 TO BE REMOVED LOW VOLTAGE CONDUCTORS MAY RUN EXPOSED ABOVE 6RD CEILING,UNLESS 33. ALL FLUORESCENT LAMPS SHALL BE 21K COLOR TEMPERATURE, UON OTHERWISE INDICATED ON PLANS. EMT FITTINGS SHALL BE OF THE STEEL COMPRESSION OR SET SCREW TYPE. 34. CONTRACTOR SHALL COORDINATE COLOR OF ALL DEVICE GOVERPLATES WITH ARCHITECT. 18. MINIMUM CONDUIT SIZE SHALL BE 1/2"C UNLESS OTHERWISE INDICATED. 35. VERIFY ALL DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL DRAWINGS. � �fj _ IJ = o A. FLEXIBLE CONDUIT CONNECTIONS TO REGES5ED LIGHTING FIXTURES SHALL BE MADE r , O WITH FLEXIBLE STEEL CONDUIT,318 INCH MINIMUM. �J I � �I !I G V N UD Z N N DIMMING SCHEDULE - PRE-FUNCTION LOAD 0 LOAD TYPE FIXTURE TYPE WATT'E3NI DcnA I- dIUANTITY 011MIMM-0IM GIRGLIIT A TOTAL HATTASIE DESCRIPTION GOMNENTS < N I FLUORESCENT BI 300W 2 FLU-DIM BI-q 600W CHANDELIER PROVIDE MULTISET 12IMIMER 2 INGANDE50E_NIT RELOCATED 200W q DIM 51-13 I600W DOWNLIGHT PROVIDE MULTI5ET DIMMER 3 INCANIDE56ErNT RELOCATED 200W q DIM BI-15 1600W DOWNLIGHT PROVIDE MULTI5ET DIMMER 4 INGANDESGE_N1T RELOCATED 200W & DIM 5I-17 1500W DOI-MIGHT PROVIDE MULTISET DIMMER 5 LOW-VOLTAGE D 50W 3 LOW-DIM BI-ICI__ 150W ADJ. DOWNLIGHT PROVIDE MULTISET DIMMER 6 FLUORE50ENT GI 501?4 6 NON-DIM BI-7 300W SCONCE PROVIDE MULTISET SWITCH I INCANDESCENT RELOCATED 100W 4 DIM 5I-21 400H DOWNLIGHT PROVIDE MULTISET DIMMER 8 FLUORESCENT GI 50W 7 NON-DIM EXISTING 550W SCONCE PROVIDE MULTISET SWITCH NOTE-5t PROVIDE ENGRAVED KEYPAD. CONSULT WITH ARCHITECT/OWNER AND ENGINEER PRIOR TO ORDER. I. PROVIDE MSP5E5 MASTER CONTROL STATION WITH MULTISET DIMMERS. 2, APPROVED DIMMING BALLAST MANUFAGTURE^R5 ARE C-51, LI6HTOLIER OR ADVANCE MARK X. REVISIONS BY DIMMING SCHEDULE - BALLROOM 06105100 MAC, LOAD M LOAD TYPE FIXTURE TYPE WATTSMIXTURE QUANTITY 0I1M/WON-0I1M CIRCUIT • TOTAL WATTAGE DESCRIPTION c4x4me TS ADDENDUM #1 I INCANDESCENT A IIOW 7 DIM 5I-23 TEOW DOWNLI&HT PROVIDE MULTI5ET DIMMER I INCANDESCENT Al IIOW T DIM BI-23 TIOW DOWNLI&HT PROVIDE MULTISET DIMMER 2 INCANDESCENT A IIOW 12 Dim BI-7! 1320H DOWNLIGHT PROVIDE MULTISET DIMMER 3 INCANDESCENT A IIOW 10 DIM BI-27 IIOOW DOMLICYHT PROVIDE MULTISET DIMMER 4 INCANDESCENT A IIOW 12 DIM BI-2q 1320W DOWLNLI&HT PROVIDE MULTI5ET DIMMER 5 INCANDESCENT A IIOW 6 DIM 13I-31 660W DOWNLIGHT PROVIDE MULTISET DIMMER 6 LOW-VOLTACvE D SON b LOW-DIM 51-33 300W ACCENT PROVIDE MULTI5ET DIMMER 7 FLUORE=SCENT 54 32P"MP 34 NON-DIM 51-35 IIgOW DOVE PROVIDE MH2O00ND 6 FLUORESCENT 54 32K/LAMP 34 NON-DIM BI-37 IIgOW DOVE PROVIDE MH2O0OND q FLUORESCENT 54 32W/LAMP 24 NON-DIM BI-3q b40W COVE PROVIDE MH2O0OND 10 FLUORE50ENT 54 32W/LAMP 24 NON-DIM 81-41 b40W COVE PROVIDE MH2O0OND 11 FLUORESCENT 54 32W/LAMP 44 NON-DIM 5I-43 1540W COVE PROVIDE MH2O0ONID 12 FLUORESCENT 54 32W/LAMP 44 NON-DIM 5I-45 1540H COVE PROVIDE MH2O0OND 13 FLUORESCENT 54 32W/LAMP 22 NON-DIM 5I-57 TfOW DOVE PROVIDE MH2O0OND 14 FLUORESCE=NT 54 32VVLAMP 22 NON-DIM 131-541 770W COVE PROVIDE MH2O0OND 15 FLUORESCENT B 500104 2 GFL-DIM BI-47 IOOOW CHANDELIER PROVIDE MULTISET DIMMER 16 FLUORESCENT G 50W EXISTING GFL-DIM 5I-4q 1000W SCONCE PROVIDE MLILITSE:T DIMMER 17 FLUORESCENT G 501`4 EXISTINI6 GFL-DIM BI-51 IOOOW SCONCE PROVIDE= MULTISET DIMMER 16 FLUORESCENT G 50W EXISTING GFL-DIM BI-53 1000W 5CONIGE PROVIDE MULTISET DIMMER NOTES: PROVIDE ENGRAVED KEYPAD. CONSULT 1,41TH ARCHITECT/OWNER AND ENGINEER PRIOR TO ORDER, 1. PROVIDE (1) #M55E5 MASTER CONTROL STATION WITH MULITSET DIMMERS AND (1) REMOTE~ MASTER CONTROL STATION #M55E5. W 2. APPROVED DIMMING BALLAST MANUFACTURER5 ARE E:51, LISHTOLIER OR ADVANCE MARK X. 3. PROVIDE LOW VOLTAGE CONTACTOR FOR MOTORIZED DRAPERY CONTROL MULTISET #MS60OND. COORDINATE WITH MICELI DRAPERY COMPANY. 0 LL! I U LUMINAIRE SCHEDULE KEY DESCRIPTION MFR. I CAT.NO. LAMP VOLTS MOUNTING NOTE MAX INFORMATION WATT A T' INCANDESCENT DOWNLIeHT LIGHTOLIER I2OPARW/GAP 120 RECESSED 1 RIO Q WITH SPEGULAR BLACK REFLECTOR 01144-1102PI 5PL/FV130 Al 7 REGE55E17 ADJUSTABLE DWNL6T L16HTOLIER 120PAR30/0AP 120 RECESSED 1 110 WITH SPEGULAR BLACK REFLECTOR 0112'15K-1102PI 5PL/FL/130 !: _ LJ B 5'-O" DIA. DECORATIVE BOWL CUSTOM SELEGTEP COMPACT 120 PENDANT 500 IN BALLROOM BY ARCHITECT FLUORESCENT 1'-6" T R BI 3'-0' VIA. DECORATIVE BOWL CUSTOM SELECTED COMPACT 120 PENDANT 300 _ Li Li IN PRE-FUNCTION AREA BY ARCHITECT FLUORESCENT 2'-0' G DECORATIVE WALL SCONCE CUSTOM SELECTED COMPACT 120 WALL 50 1 BY ARCHITECT FLUORESCENT J GI DECORATIVE WALL SCONCE CUSTOM SELECTED COMPACT 120 WALL 0 50 PREFUNGTION AREA BY ARCHITECT FLUORESCENT EXI5TINS HEIGHT < V 14" VIA. RECESSED DOWNLI&HT LITON 50MR16/XP/ 12 RECESSED 2 50 4-d- WVPULL DOWN ADJUSTABLE TRIM 0LRI347/LHI344 NFL/25 E IEMERGENCY CONGEALED LIGHT HI CONIGEALITE (2) 35MRI6 120 RECESSED 70 NICKEL CADMIUM BATTERY 0F5-35-2-120-RT-PT-NC BAT CEILINS 54 141-o" FLUORESCENT STAGGERED LISHTOLIER (2) F032-T6 120 COVE 3,4 65 .... .-. , STRIP-(2) BALLASTS 05T6232R5-ELEC. BALLASTS 3000K SURFACE 5 MOUNTING ABBREV1AT_I0 LLJ AFF - ABOVE FINISHED FLOOR PL - PENDANT LENGTH O BFG - BELOW FINISHED CEILING, PH - POLE HEIGHT L_L_l LLj RFD - RECES 0 FIXTURE DEPTH NOTES: I. PROVIDE OSRAM/5YLVANIA LAME' 0120PAR/CAP/SPL/FL q 130 VOLTS VENDER 014861. 2. PROVIDE SOFT FOCUS LENS WITH EACH FIXTURE. 3, PROVIDE ELECTRONIC DIMMING, BALLAST. ACCEPTABLE MANUFACTURERS ARE E51 DIM-E,LIOHTOLIER OR ADVANCE MARK X. SCALE: NONE . 4. REFER TO COVE DETAIL SHEET E3.1 FOR MOUNTING 4 REFLECTOR DETAIL. PROVIDE THEATRICAL WHITE 51 NEFOI L #200112 BY ROSGO. 5. PROVIDE (2) ELECTRONIC BALLASTS PER FIXTURE FOR DUAL LEVEL SWITCHING. DESIGNED: MAC, CHECKED: RES JOB # I01g61-1?4-00 DATE: I2-21-Gq A0 REG/s i/�� ?,,. ,:w ❑ Ll <<r,rn f 1EEt+ttt W"Ift. f oO M 8u LT A IT I 1123 AURARIA PARKWAY, #400 DENVER, COLORADO 80204 303-623-6200 FAX 623-8435 I I o O � n I � - - - - - - Ll o w Lo LL) .- In W0N � z (.6 ❑ cnJN z z ^ N N co w o 3�: v o W Lo � � N 0 N z N 1 IS � N TING N a 0 • 0 DIMMI CONTROL ® ® O p ® ® �� S T ION N O O - PHONE REVISIONS BY ® I O p 6/05/00 MAC a I DDENDUM # IL O \ I I 1 MICROPHONE PHONE I W L7 ® < z C ENERAL NOTES _o 4� U I. PROVIDE A NEW DECORATIVE BLANK COVERPLATE IN ALL Q) �✓ AREAS A DEVICE HAS BEEN REMOVED. REFER TO D —� ARCHITECTS SPECIFICATION FOR COVERPLATE COLORS. Q REFER TO SHEET A-1, . U W 2. ALL DEVICES SHOWN SHALL BE DEMOL15HED, MAINTAIN 0 J LLI CIRCUIT f O Q REMOVEDTEGRITY UP AND DOWNSTREAM OF DEVICE BEING ED W Q ® PHONE ® MICROPHONE oo SCALE: 1/4" = 1'—O" DETAIL NOTES DESIGNED: MAC, O SCONCE SHALL BE REMOVED, GLEANED AND PACKAGED CHECKED: REB FOR STORAGE. 5GONCE SHALL BE RETURNED TO OWNER. MAINTAIN CIRCUIT INTEGRITY FOR NEW SCONCE TO BE INSTALLED AT EXISITNG LOCATION. O SCONCE SHALL BE REMOVED, GLEANED AND PACKAGED JOB # FOR STORAGE. 50ONCE SHALL BE RETURNED TO OWNER. MAINTAIN CIRCUIT INTEGRITY UP AND DOWNSTREAM OF DEVICE BEING REMOVED. DATE: 12-21-qq `\���alutn�t n r r r u urppi ELEGTRI GAL FOl ER DE�0L I TI O\ FLAN N E2.o 1/4 = I _D 101 ti Ro ( l fl�rlllfr?I • �111111*`��, I U OONSULTANT• IN 1123 AURARIA PARKWAY, ;400 DENVER, COLORADO 80204 303-623-6200 FAX 623-8435 Q • O 0 co 0 _ 4 W BI I Q O B1-1 O O O 81-7 Q BI-1 - - 51--� W rIV) lrU Gt CA I-3 GI at Gl at GI at ct —j V) o I I I I I I I i w (c) Lo 6" CLEAR �J ~ V W — Lo wotN BI-G1 (W fW I BI-1 � z 12" GL R t�f} � N T • PANEL .► N BI Z 5 rrU I o oo o ro BI-5 111 LL � s I V wr o � NEW 4 .1 V o 5 3 DIMMER BANK B I-8,10,12 In Q (E) (E) lw lE (E-) N rw 1 Q0 G lw C ENERAL TES z N (E) Q r G rw N DIMMER BANK lf=J G G I. ALL SCONCES TYPE "G" 8 "GI" ARE NEW. LOCATE FIXTURES _ Q N OF 10 MULTISET DIMMERS BI-32,24,36 AT EXI5TIN J-BOX LOCATION. r AND (1) M5P5 2. (E) INDIGA E DEVI �5 iSTING TO REMAIN. z DRAPERY (N) INDIGA E DEVI S TH T ARE NEW. CONTROL ® t� DETAIL N I Q PROVIDE GOVERPLATE FOR J-BOX. OR PE ARCHITECTS SPECIFICATION, EXISTING POWER O RE A IN FOR FUTURE USE. REFER TO SHEET A-1. I REVISIONS BY o G 142 NOT USED. I 6/05/00 MAG 5 PR VIDE NEW DECORATIVE GOVERPLATE AT J-BOX WH E ADDENDUM # PHONE D I E WAS DEMOLISHED COLOR PER ARCHITECTS IN E G N EF R T SHEET -I. QREUSE EXIS INS CIRCUIT AT TH15 LOCATION TO POWER NEW 5GO G . MOUNT AT EXISTING J-BOX HEIGHT. Z6 BI-44,51,53 7- 11 G 0 ROUTE PH E/DATA FOR P.O.5. I N I" CONDUIT TO HUB 1 I CONVERT R LOCATED IN PAYROLL OFFICE #004. QPROVIDE E DECORATIVE GOVERPLATE AT J-BOX WHERE EXISTING I ROPHONE DEVICE WAS DEMOLISHED. GOLD MEE R R T T P IF ATIO REFER TO 5H T A-I. I I r� Q PR ELLIPSE 6-BUTTON MASTER DIMMER CONTROL BY L GHTO.LIER. MODEL #M55E5. PROVIDE ENGRAVED KEYPAD. Q PR DECORATIVE VERPLATE AT J-BOX WHE E EXISTING RE EPTAGLE S DEMOLISHED. COLOR PER ARGHITEGT5 SPECIFICATION. R . QCUSTOM POWER/DATA WALL BO CONTRACTOR SHALL O � PROVIDE 6 INSTALL IN WALL 8 X (1) HUBBELL LOW I PROFILE 6OA/3P REGEPTAGLE DEL #A460Rq, (1) 3CA/3P RECEPTACLE MODEL #HBL151430 AND (1) HUBBELL GAT 5e z SERIES PATCH PANEL MODEL # G 5806110AIGE FROM HUBBELL PREMISE WIRING. Q CONTACT CRYSTAL ABSHIER-O S N WITH PREFERRED CONNECTIONS INC. 303-763-q14 LL BOX SHALL BE INSTALLED IN WALL AT LOGATI N SHOWN. COVER DETAIL TO MATCH EXISTING PANELING. PE ER TO ARCHITECTS SPECIFICATION FOR COVER REdU1 EMENT5. REFER TO rE) WALL BOX SECTION THIS SHEET. W I Qo PROVIDE NEW DECORATIVE GOVE PLATE AT -J-BOX WHERE „ „ 0 5I-26,28,30 1 . COLOR PER BI-44,46,48 G 0- BI-207224 G BI-14,16,18 t ARGHITEGT5 SPEGiF1GATION. REFER TO SHEET A-I. 4 u MOTORIZED DRAPERY SHALL BE CONNECTED TO CIRCUIT q 5I-55. PROVIDE LOW VOLTAGE INTERFACE W/DIMMIN(9 <[ q I SYSTEM. L 4� — LIGHTING DIMMER BANK. PROVIDE LIGHTOLIER DIMMER FOR 1 MASTER j EACH LIGHTING CIRCUIT. REFER TO DIMMING SCHEDULE ON SHEET E1,0 FOR DIMMER TYPE AND LOAD. PROVIDE (1) DIER r�SOMNMTROL ELLIPSE MULTISET SCENE MASTER CONTROL STATION. '_ U lW b PROVIDE (1) #M5600 NO FOR DRAPERY CONTROL. LLJ 3 b 8 I <@ PROVIDE A 150 KVA TRANSFORMER. TRANSFORMER SHALL (c LLJ G ft=J fw it G(t= r>=) tt G ii COMPLY WITH NEC Iqqq SECTION 450-21b EXCEPTION #2. NO Cc) <G LIGHTING DIMMER BANK. PROVIDE (1) LIGHTOLIER DIMMER FOR EACH LIGHTING CIRCUIT, REFER TO DIMMING SCHEDULE ON SHEET EI.O FOR DIMMER TYPE AND LOAD. PROVIDE (1) ELLIPSE MULTISET 5GENE MASTER CONTROL STATION. SCALE: I/4" = I'-D" EX15T. WALL 145 TELEPHONE PUNGHDOWN BLOCK. PROVIDE (4) 25PR DESIGNED: MAC, j PHONE/DATA EXIST. UPPER PANELING PUNGHDOWN BLOCKS IN OFFICE.-BY E.G. ELEGTRIGAL HOOK UPS BY OTHERS EX 15T. CHAIR RAIL PANELING CONTRACTOR SHALL ROUTE GAT5 GABLE FROM OFFICE CHECKED: REB TO SERVER ROOM BELOW. PROVIDE 30'-0" OF GABLE NEW MASONITE BOX PIANO HINGE COILED IN SERVER ROOM FOR CONNECTION BY OTHERS. BUILD NEW BOX W/IN I REMOVE EXIST. PANEL(I) FIELD VERIFY CLEARANCES PRIOR TO INSTALLATION Or- EXIST. v WALL I ALL EQUIPMENT. JOB # Ia41q-174-00 I 1 I MODIFY TO BE SWINGING PROVIDE NEW SWITCH BANK LOCATION. PROVIDE (8) MULTISET ON/OFF KNOCK-OUT FOR L_j 1 OSWiTGHES FOR THE DUAL LEVEL GDYE LIGHTING. FINAL WIRING/POWER. 1 I PROVIDE (21 J--BOXES FOR RECEPTACLES LOCATION PER ARCHITECT/OWNER. a DATE: 12-21-1441 j EXIST. BASE FLOOR r ' non ELEGTRIGAL FO��ER FLAN ELEGTRIGAL ��ALL E30X SEGTION u N.T.S. x •°w: ❑ rr N AL rrriirrr�lrrrttttN»����� 4` CONSULTANT• LNG' r f123 AURARIA PARKWAY, #400 DENVER, COLORADO 80204 303-623-6200 FAX 623-8435 i O V r o Q „ o 0 W � � ('oQ (Ru �u o _J ® Lo cRu rRu ©(Ru c"u 0(Ru (Ru ®(Ru rRu I— V) !,f) W — L0 W O CSI cy z • 0 0 0 0 0 0 ❑ �- - � U} � N O O O O O 0 -- N (Ru .. N o(Ru o(Ru o(RL) o(Ru O O O O O O 1 o (Ru I, 01 co ro S ©(Ru ©(Ru I, Q ©(Ru ®(Ru 1 LL 0 0 0 ®(R`' 0(� O(R� 0 Cn (RL) (RL) (Ru lRu W I o °lRu 0 � U o o W Lo C� N N N lRu O(RL) 0(RL) OIRu 00Ru O(Ru orR:., o(w, 0(Ru O 0 O I i (RL.) (� (RL) ( I REVISIONS BY 0 1 © © o &0b105100 MAC �f O O O O O O O !(RU ADDENDUM # . � S f (Ru! ©(Ru O O ! o O o 0 0 0 o O ©(RQ (Ru® 0 cRu I 0 mu NO O o o O Li 0 0 O O I IJ I (Ru•S 0 0 0 o O O o ( z ® (RL) s ❑ = z 0 0 GENERAL NOTES G(PL) •�U I. ALL DEVIGE5 SHALL BE REMOVED IN DEMOLITION WORK, J Z G I ALL FIXTURES SHALL BE GLEANED, PACKAGED, AND Q RETURNED TO OWNER FOR STORAGE, UNLESS OTHERWISE U O NOTED. 4-1 � a O o 2. MAINTAIN CIRCUIT INTEGRITY UP AND DOWNSTREAM OF J 0 0 0 0 0 0 o s--- ' f DEVICE BEING REM©VED, O 3. REMOVE ALL FIRE ALARM DEVIGE5 DURING DEMOLITION c LJ-J c OF EXISTING GEILINO. GLEAN ALL DEVICE COVERS C) -i W AND STORE FOR REINSTALLATION IN NEH HORK. W 4. DESIGNATION "RL" INDICATES DEVICE TO BE GLEANED, RELAMPED AND INSTALLED IN NEW WORK. j 5. ALL 0OHNLI0HT5 IN THE PRE-FUNCTION AREA SHALL BE GLEANED, RELAMPED AND STORED FOR USE IN NEH WORK. SCALE: 1/4" = 1'-O" 5EE SHEET E3.1. DESIGNED: MAC, CHECKED: RE8 JOB # I4191q-l-14-00 DATE: I2-21-aq E J_.-_.E G I R I G A L L D E M O L-- M O l Y. FLAN Q.• �, u DE3. 1 /4"_ l�-Q k � a o v. 26r' 3 ❑ rx; age QONOYLYAMTS fN0 1123 AURARIA PARKWAY, #400 DENVER, COLORADO 80204 303-623-6200 FAX 623-8435 71 I � O U J Q a Q I � ° (o o f � w co O (Ru O , O (RL1 O mu O (RU O mu (Ru O (RU (Ru (W O (RI O (w O (Ru � A (RL) A (Ru A (p ©(Ru mu A � wo OBI-13 OBI-15 OBf-15 OBI-15 Q� 0BI-15 Q OBI-11 a OB1-11 ® OBI-11 0WI1 (RU OBI-11 OBI-17 Q� ® O2 CBI-21 O BI-21 O BI-21� *5 0051-21 Lo Lo ( (wQ © w - Lo w o cv � z • Llmu BI-9 BI-q O2 I-' (n J N Oi 0BI-(RL) iO0(RL) 'VO(wa Oi 0(R-) I N 13 BI-13 BI-13 BI-15 z BI BI ~ N (Ru 01 000Iso s X. Q �- U LL! i RI�Y�� 1 Q !RU O (RU O (Ru ©(RU 4"0, !RU ®( V (RU '0>, (RU �! L) I NEW � � � O ();1-13 � 0 O fRLJ � 0;1-15 S /-DIMMER BANK 50 � w BI-13 BI-13 0;1-15 D BI-150 D BI-I5 BI-15 � U Bl�-Iq 51�-ICI 51�-Iq B�q `-`- MA5 R I N O DIMM R GONT OL �. ❑ N 151-35,37 , B 1-35,37 EI-35,37 B 1-35,31 BI-35,31 B f-35,37 B 1-35,37 B 1-35,37 B I-35,37 B 1-3531 B 1-35,37 B I-35,37 B 1-35,3? B 1-35,37 B 1_ 57 35,3 B 1-35 - (R� C 1-13 OBI-1 AI BI-31 A A BI-31 BI '6 Al �4 AI A4 Af� � 4 B2q 51-21 51-21 B1-27 E31-25 25 51--25 E31-25 25 E31-23 23 � � N N• 51-23 5 54 54 54 54 54 54 54 54 _ 54_ _54_ _54 54 54 6 BI-43,45- � BI-43,4 BI-43,4 BI-43,4 51-43,4 BI-43,4 BI-43,45 BI-3G, 1 D AA I ! 4 151-43,45 Nw 54 54 OBI-33 4 PROVIDE (2) BALLATS PER, FIXTURE, RU ©( ) (�) 51-43,45 ( PROVIDE DUAL LEVEL REVISIONS BY Q +♦ ® BI-3G,4 WHITE SWITCHING. CIRCUIT I-39,4I Al � A A A A 5 A A An Al B1-23 1 51NEFOIL INBOARD LAMP TO I 0 6/05/00 MAC 4 B0 1 81-027 BI027 BI021 BI025 BI025 E31-25 '2 O REFLECTOR CIRCUIT NUMBER ADDENDUM # BI- 3 54 I S4 ('DBI-33 5 1 INDICATED AND CIRCUIT BI-43,4 I - OUTBOARD LAMP TO �BI-43,45 i ; GL CIRCUIT NUMBER (RU �® 54 54 - 54 - 4 _ 54 - 0S BI-39, I INDICATED. 1-3q,41 (RU - --- 54-- -�-- !� O PROVIDE BLOCKING �{ BI-43,45 5 _ T © 54 43,45 4 IF NECESSARY Al 54 A A AIO 3 8029 0 81-57,59 BI-57,56 (� 61-23 BI_2q 54 54 81=23 5I-3q,4 I I-3q,4I BI-43,41 A A A I 5I-43,45 S I 54 B11 31 51-3I B°1 I S4 2 �D Y DETAIL BI-57,5 �I-57,59 D E3.I N.T.S. 51 �4 (>BI-33 BI-3G, I -39,4! B 1-43,45 4 AI A (R 5I-47 BI-47 Al 4 A (RU 4� ® - Bq B1-q (RL) B1�3 843, 23 54 i ® I (>B1-33 BI-39,41 \, BI-3q,41 B 1-57,59 I B B 54 { I B I-43,4 D I 4 B 1-43,4 ; B 1-57,56 5 I 54 AO AO AO 54 z u BI-57,5 51-31 51-31 51-31 I-57,59 Q I A S 4 A - i I 1-39,41 Al 0 r - - r 813 A 0 4 4 BI-29 E31 2q 54 f I 54 BI-23 BI-43,45 (RL). � - - -_ - _____ - � 1 2 51-43,45 �' U ' S 54 S 54 5� 54 ' - BI-39,4 I z I BI-3L1,41 !FZQ 0 , BI 43 4 54 (RU i 4 5 - , 0 i ❑ I Z ,q - , S 814345 Al A A (RL) A (Ru A A (RL) A ® A (>A I I U a O 0 © O •c, 0 0 ® 0 0 BI-53 0 I GENERAL. NOTES J E31 23 81-23 BI-39, BI-2q BI-2q BI-27 BI-27 BI-25 5I-25 BI-25 I I-39,41 1, DESIGNATION (RL) INDICATES A RELOCATED DEVICE. - 4 5I-43,45 51-43,45 4 I 54 ®( 54 BI-33 2. ADD ALTERNATE: Q 17�D i PROVIDE PRICING FOR A (1) LAMP F032T&/2700K U i STAGGERED STRIP WITH DIMMING BALLAST. PRIGS FOR I-4 4 I-434 ' 1-4 4 f Bf-4345 BI-4345 BI-39,4 �' - BI-434 B 3 5 B B 3 5 51-43,45r,- , ALL COVES. OMASTER I-36,41 � � - - - - H - - 4) DIMMER 4 54 54 54 54 54 54 54 54 54 - 54 54 54 54 5 ! 3. ALL DIMMER 5WITCHE5 SHALL BE LABELED TO IDENTIFY : FIXTURE BEING GONTROLED. - (, CONTROL - � Al AI Al AI Al Al Al AI AI a O 0 O 0 0 O O 0 ! I 4. REINSTALL ALL FIRE ALARM DEVICES IN EXISTING w 1-36,41 BI-2q E 5I-2q 5I-27 5I-27 5I-25 5I-25 BI-25 BI-23 5I-23 BI-39 LOCATIONS -.� ATIONS INDICATED. REFER TO RG-I. E 4 0 BI-31 �4 m Li B I-35,37 E31-35,37 B I-35,37 51-35,31 B I-35,37 E31-35,3-1 51-35,3-7 B 1-3537 B 1-35,37 B I-35,37 B 1-35,37 B I-35,3? B I-35,37 B I-35,37 B I-35,37 B f-35,3 T B 1-35,37 I 1 r ) ( ® DETAIL NOTES O RELOCATED 7" DOWNLIGHT. LAMP WITH 2OOA23/IF LAMP. SCALE: 1/4'*'-0" ADD ALTERNATE: PROVIDE PRICING TO REPLACE RELOCATED FIXTURE WITH FIXTURE TYPE "A" IN LUMfNAIRE DESIGNED: MAC,SCHEDULE. O RELOCATED 5" DOWNLIGHT. LAMP WITH IOOAIGI/IF LAMP. CHECKED: iZEB ADD ALTERNATE: PROVIDE PRICING TO REPLACE RELOCATED FIXTURE WITH FIXTURE TYPE "A" IN LUMINAIRE SCHEDULE WITH ciOPAR38/FL LAMP. O LIGHTING DIMMER BANK. PROVIDE LIGHTOLIER DIMMER JOB # Iggq-1-14-00 FOR EACH LI6HTIN6 CIRCUIT. REFER TO DIMMING SCHEDULE FOR DIMMER TYPE AND LOAD. PROVIDE (1) ELLIPSE MULT15ET 5-SCENE MASTER CONTROL STATION. PROVIDE (f) #M5600 NO FOR DRAPERY CONTROL. DATE: 12-21-qq 4O PROVIDE (1) ELLIPSE 6-BUTTON MASTER DIMMER CONTROL BY LIGHTOLIER. MODEL #CE&BE5. LIGHTING DIMMER BANK. PROVIDE LIGHTOLIER DIMMER ���G Tfi� G�� � C�T 1�C PLAN FOR EACH LIGHTING CIRCUIT. REFER TO DIMMING SCHEDULE FOR DIMMER TYPE AND LOAD, PROVIDE (1) ELLIPSE MULT15ET 5-50ENE MASTER GONTROL 5TATION. 1/4"= I O NEW SWITCH BANK LOCATION. PROVIDE (8) MULT15ET ON/OFF SWITCHES FOR THE DUAL LEVEL COVE LIGHTING. _ FINAL LOCATION PER ARCHITECT/OWNER, i ooK.uL ,AMT• INC • 1123 AURARA PARKWAY, #400 DENVER, COLORADO 80204 303-623-8200 FAX 823-8435 PANEL 5GHEDULE mmm FmmcamTm FHA% AMA SHORT G I R GU I T 5G HE DUL E PARTIAL LOAD SUMMARY PANEL ND: Bd 08-,�,-0c, 1 6NED POI D-5CRIPTION I x SYM RM5 EXIST1NO 12010 A 95tV E 480V/2T7,3P,4H LOCATION, OFFICE VOLTAGE L-L: 206 2 U1 AS%SrAED XI MAIN DISTROUTION CENTER 31 TOTAL AMPS PRO.EGT: VAIL-BANQUET ROOM VOLTAGE L$+ 120 3 3[4�O�OMIGI'ti 3-IR'G1 3-44 °•�00 X2 PRIMARY 510E 22"51CVA TRANSFORMER GH-1 160 AMPS ,JOB NO.3 mq-1014-00 TYPES 3PM"1 4 8I4-400MCK 3-1/ 3.44 20070 15;!83 CAMS: n pow-1 (14 x 1,25) 18 AMPS -. AIG 400A SL.RM15 RATING:13115 RATING: G: 22 5 4(5-35OMCM,1-3/00,3Y,] 3-34+8 1200 X3 SECONDARY SIDE TRANSFORMER 14,010 4 ,000 FUMP-1 14 AMPS MAIN O.G.DEVIGEe 400 b 44-350MCM,1-3/09,3'01 1200 r `1 6,515 _ � �..•!. MOUNTIN9a SURFACE 7 3(3-40b!'IC.M,1-2/06,3'6] 3-3*6 1000 X4 PANEL K3B PAkwEI. 11" 78,219 AMPS � - 8 3{4�O�K,M,1-2/019,310] 3-44+6 1000 PRIMARY SIDE 150KVA TRANSFORMER 21,723 CAR DEVICE C.ONNEGTED DEMAND LOAD LOAD DEMAND CONNECTED DEVICE GIR 4 3[3-300MGM,1-1/06 3"G] 3-34+6 1500 PANM. "S1 I 30853 AMPS' NO. AMPS POLE VA FACTOR SERVED SERVED FACTOR VA POLE AMPS NO. 10 3(4-300MGM,I-1106,3�G] 3-44►Ei SECONDARY 510E OF 2.jBy f " 57861 AMP' - - - - - TOTAL LOAD ON PARTIAL 1200 SERVICE • 101 II 3(3-250MGM I-1106 3'G] 3-34+6 750 I I 20 1500 1,0p PRE-FUNGT.RPT. SPARE I 3 60 2 � X7 PANEL Li � O �fdbl AMPS 3 I 20 1500 I.pp PRE-fgAdGT.RJ°T• SPARE 3 eo 4 12 314-�GM1,1-1/06,3"G] 3.44+6 7r0 b� 5'78bIA<1200A 5 1 20 1500 1.00 PRE-PUNGT.MDT. SPARE 3 60 6 13 �350MGM,19*1 3016] 3-34+6 600 X& PAN1:1 K3G O [V�] 7 1 20 600 (M PRE-PUNT,SCONCE x 1.00 '5'73.1 3 60 8 01,424 PEAK METERED DEMAND D PROM HOLY C4kM*UTILITY. (753 Ax1.25) "3 ASS 01 1 20 600 IM PRE-FLINT.GRAND MALL BOX TAO 5-57 3 60 10 14 2(4-350MGM,1il16,3'G] 3-4416 800 2000A SBINK.E 11 I 20 SPARE HALL BOX 100 5757 3 80 14 5 2[3-250MGM,1026,3061 3-34+6 5010 1 13 1 20 1800 1$ PRE-FUNT.DHNLT WALL BOX IA" 5'157 3 60 14 TOTAL LOAD ON 2000A 9CRV Wo (578.81+ Q413)A = 1520.11 APP I3 1 20 1800 1.25 PRE-FLINT.DHNLT HALL BOX 1.00 5757 3 60 16 Ib 7(4-230h1GM,10a5 3'G] 3-4L*1+F 500 17 1 20 1500 1.2'3 PRE-FOUNT.D"CT HALL BOX 1.00 5757 3 60 16 i1 7133/0,1039,2.01 3-34+6 400 DETAIL NOTES W 1520,IIA<2000A A 1 20 150 1.25 PRE-PANT.AGGI=NT HALL Box 1.00 5757 3 60 20 18 2[43/0,lgs,2%] 3-44+ 400 <> PROVIDE NEW SXKET, 5TUB5, LU65, TERMINATION, 21 1 20 400 1.25 PRE-�FUNT.DHNLT JNALL BOX 1,00 5757 3 60 22 Iq ZS-20,IM,2001 3-34+6 350 0OVERPLATE5, ETC. FOR A COMPLETE INSTALLATION. Li -- 23 1 20 1540 l.25 BALLROOM DWNLT WALL BOX 1.00 5757 3 60 24 20 7(4710,11136,2'G] 3-44M3 3150 25 1 20 1920 IM BALLROOM DWVLT HALL BOX 1.00 2879 3 30 26 30 o 27 1 20 1100 1.23 BALLROOM DHNLT WALL BOX 1.00 28701 3 30 26 21 3-350MGM,1046,3'G 3-34+6 0 2q 1 20 1320 1.25 BALLROOM DJNNLT HALL BOX 1.00 287q 3 30 30 22 4-350MOM,11146,3Y, 3-44+8 0 31 1 20 660 1.25 BALLROOM 0104&T HALL BOX 1.00 2D 74 3 30 32 30 �3 ' n 33 1 20 300 IJ5 BALLROOM AGGENT HALL BOX 1.00 2879 049 3 30 34 23 3-25OMCM,1 ,3Y, -34N9 250 Ll J 35 1 20 1140 1,23 BALLROOM COVE X IAO 26-A 3 30 36 24 4-250MCM,1046,3016 3-4W�8 250 37 1 20 11010 I.$ BALLROOM COVE @Ex`� 3 30 38 3q 1 20 840 1.23 B0kL-ROOM COVE 3 30 40 3-4AO,1M6,2'G 3-34+d 229 W 41 1 20 840 1,25 BALLROOM COVE 3 30 42 26 4-4/0,1#40.2-1/2Y, 3-44+6 225 Lo 43 1 20 1540 1.25 BALLROOM COVE 1.00 26-M 3 30 44 27 3-3/0,10166,2% 3-34+4 2010 W O N 45 I I M DOVE WALL BOX 1.00 28701 3 30 46 2$ 4-3/0,1089,2'G 3-4W�f 200 • 4 WALL BOX 1.00 2874 3 30 48 4 I SCONCE I I 20 50 24 3-210,1088,2'6 3-3W+fi 175 � f 51 1 20 250 1.25 BALLROOM SGONGE SPARE 1 20 52 30 4-210,108s,2y, 3-44+6 175 -I 53 1 20 150 1.25 BALLROMM SCONCE SPARE 1 20 54 31 3-1/0,1066,2"G 3-34+6 125-150 J o >� ! 20 56 _„_ N I 57 I 2 770 1.25 BALL COVE BUSSED SPACE 58 32 4-I/0,1066,Y6 3-44+6 125-150 54 I 201 770 1.25 BALLR00P�COVE BUSSED 0 SPACE SPACE &C 33 301,11 6,1-1/286 3-3J�1+6 100-110 z = w 63 BUSSED SPACE BUSSED SPACE 64 34 401,1066, 1-1/2'6 3-44+6 100-110 N b5 0 BUSSED SPACE BUSSED SPACE 66 35 302,Aft 1-11486 3-34+1 40 i� r' b7 BUSSED SPACE BUSSED SPACE 68 36 402,10156, 1-114'6 3-44+1 90 O `(-0 ro b4 BUSSED SPACE BUSSED SPACE 70 37 303,40156 I-114"6 3-34+6 80 �' "71 9U��ED SPACE BUSSED SPACE 72 73 BUSSED SPACE BUSSED SPACE 74 36 403,10156, 1-11486 344+6 150 LL -75 BUSSED SPACE BU95ED SPACE 76 34 304, 10158,1-1/4"C 3-34+6 60-70 �/ 77 BUSSED SPACE BUSSED SPACE 76 74 BU95W SPACE BUSSED SPAGIr 60 40 404,1",1-1/4'6 3-44+6 60-110 V) 61 BU55M SPACE BUSSED SPACE 62 41 3016,10109,I'G 3-3H+9 50 I I = O 83 BUSSED SPACE BU55ED SPACE _.„ ___ 54 42 4#6,1009,I'C 3-44+6 50 I� O CONNECTED LOAD: DEMAND LOAD: 43 3118,10106,1'G 3-34+6 40 I I PH A VA = 35,916 PH A VA a 31) "Ib 44 4118,10106,I'G 3-44+6 40 W In PH B VA = 35,006 PH B VA • 36,408 PH G VA : 34,718 PH G VA a '36,54b 45 3010,111106,3/4'�G 3-3k+& 30 TOTAL VA = 105,544 TOTAL VA = 111,144 46 4010,1111M.314-6 3-44+6 30 I 1 ^ 1 ,• TOTAL AMPS = 30853 41 3012, 10126,3/4.6 3-3W+s 20 48 4012,10121%3/4'6 3-44+1 20 NOTES: 44 W6SI6NW V UNASN&ED N DOUBLE NBITRAL FEMO�6 • 51 301,201 N,I%G,1-1n"G 34H+6 100 N 52 3-1/0.2-1/0 N, 1",2'6 3 4W 6 150 �. 53 5-25OWM,2-250MGM N,1046,3'6 3-401+9 250 54 2'03/0,2-3/0 N,1036,2-112'6 3-4W+e 400 55 2(3-25OWM,2-25OWM N,1026,3'G 34H+8 500 56 13-250MGM,2-250MM N,1-1/00 3'6 3-44+6 750 51 UNA55&W 58 UNA55167ED 54 UNA55i&ED 6ROIINDINS CONOUCTOR5 REVISIONS BY 60 11169,1/2'6 6 61 106,112-6 s A06105100 MAC 62 184,3/4-6 ADDENDUM #I 63 102,3/4C 1 64 1-1/0,3/4-0 1 65 1-210,3/4'6 1 66 1-3/0,3/4Y, 6 NOTE, ALL f4N=TORS Alit IX-TH NLOPPM LI LM NOTED OTH944W. 3l2bAi'7 I EXISTING IOOA PANEL PANrZL 120/208, 3P 14W K213 (DEDICATED TO P.C.5. 5Y5TEM) E45T. 225A PANEL 42-GIR(..UIT PANEL i20/2043, 3P 14W EXI57NC 200A PANEL K3G 10,000 AIG PANEL 120/208, 3P/4W K36 RELOGATED IN NEW WORK X15 EXI57NIS 400A PANEL �� X4 1201208, 3P/4W PANEL ( K2 I00/9P EXIST. 400A PANEL 2j(4 #500,MGM)3-I/2"] PANEL !20/208, 3P/4W PANEL ISOA/3P 16 NEh"A 39 BI (4 #500,M(:;M)3-1/2 11C 6COA/3P j 225A/3P 22,000 AIG 400 1 BREAKER \ p 1 G 400±85-R TO BUILDING STEEL 400A PUMP PUMP TO 5UALPlNC STEEL �� (1k13/0,60)3/4 G (5081) 18 2 18 W EX15T1NC� 5UBD15TRIBUTION BOARD (PARTIAL) TO BUILDING 57EEL 0 0 TO BUILDING STEEL Z X3 �� x6 EXI5TINCG 150KVA 150KVA -RANSPORMER V13 7H WEATHERSHIELp (I#3/060)3/4"G TRANSFORMER / � E'KISTiNC7 200A PANEL PANEL 480, 5PH.51A PRIMARY 480, 3PH.,3N PRIMARY V 1 EXISTING 112.5KVA EXI57NO 225KVA 480/277, 3P 13W PPI 208/120, 3PH.,4W 5EGONDARY 208/120, 3PH.,4Yd SECONDARY �n TRAN5I=0RMER TRA`15PORMER hI (45 45 GH-1 50A/3P 3OA/3P W 3oA F HOLY GROSS PEAK DEMAND X2 X5 IP 200A3P F2N 3DA FRN READINO AT 625KW, (3#3/0,60)2 G WIREWAY 0 LJ O 25 2G 25 _". W ( 41 �,000 Q LEY THRU FRS-R ER5-R FR5-R ERS R PR5-R PRS-R i<RS_FZ __j 75A 550A 200A 2 I W �.`5A 17 A 4 A 5 5 .. .... 225A 0 , CT U XI � 200/3 400/3 20013 400/3, 20013 60A3P 400/3 W z 200 A 3P -1 �l I O / 2000 AMP, 480/2`I-fV, 3P,4W 200 AMP, 480/277V, 3P,4W EXISTING HOLY GRO55 7RAN5FORMER -� 6[4-400MGi l3"G] 1000 KVA 5.68 96 Z EXISTING MAIN SERVICE 5WITGHB0ARD (NOT ALL DEVIGE5 SHOWN) SCALE: NONE 1 FIR'5T FLOOR NOTE: ALL FOJ PMENT SHONN L c-7HT LINE N� CHT F,`C!ST1NC, DESIGNED: MAC, E301-D L'1 NE AE 1 CcHT I ND I GATES NEN k OR< TH I e GONTRAGT. - CHECKED: REB JOB # I014101-174-00 DATE: 12-21-qq ELEGTRIGAL ONE -LINE PANEL SCHEDULES E4.o NONE w NAL„� i��``�J'.