HomeMy WebLinkAboutVAIL LIONSHEAD FILING 1 BLOCK D LOT 1 --�_-- • sa W �� U �� q �� �_ � s • VAIL RESORTS DEVELOPMENT � w � � � VAI L COL4RAD0 � , � � LIFE SAFETY DRAWINGS � � � oo � � � 0. � � � � � ` � w Q Index of Drawings � � � Drawing Drawing Note 1 . Heights ahown are liated in NFPA 72 Standarda 2002 GENERAL NOTES : � � � CHAIR 8 SKIER SERVICE BUILDING Number Name Note 2. Where ever devicea ore indicated to be above doors, the device eholl be '""''°• Qa1ef r°°' °iaR VAI�, COLORADO 7 . FA1 .0 COVER SHEET centered between top of door trim and ceiling line. � �� � � �eaw � � � o 2. FA2.0 FlRE ALARM FLOOR PLAN CALCULATIONS 1 -LJNE DETAILS GRAPHIC MAP Note 3. Theae are NFPA liated Mounting haights, and any mounting heighta liated w,npn.r towano O GOVERNING CODES in the Specifications or shown on the Archifecturol Elevations shalf ovem rner � thoae ahown here. M dixre on ahall be a roved b the En ineer of Record. � - o eiod� - o ewa� � o - o�,m cad - a� W � Y P �Y PP Y 9 ero.n - � e.wn - 1 ero.n ■ 10 sMr - ta Cr �o ^ - 2003 INTERNATIONAL BUILDING CODE Note 4. ADl� Strobea are to be placed 80' above the higheet floor leve� with�n the w� - 2 �.a - Z n.a ■ ioo np+• - a� x Q `� � - 2003 INTERNATIONAL FIRE CODE space or e below the ceiling, whichever is lowest. °iviqi - � °rarqi - � °ranqi " ��0°° ' K °�'" In Sleeping Rooms if the strobe ia mounted lesa than 24" from the ceiling, the � � 6 � : y �p,��, ; �°p'p,p°0°pp � � - 2002 NATIONAL ELECTRIC CODE (NFPA N0 . 70� strobe must be 1 �7 CD. If the atrobe ia 24' or bplow, it must be 110 CD. r NFPA ew,� � e eiw _ e aa„ . � ,000,oao � Y oAm - 2002 NATIONAL FIRE CODE (NFPA N0 . 72� SCOPE OF WORK 7able 7.5.4.4.2. The atrobe must also be within 16 of the pillow. Per NFPA /�.5.4.4.3. � - � vto� - � sw.. / �oo EW FlRE ALARM SYSiEM. Note 5. Remote Li hts, Remote Test Switches, Control Modules and Monitor Modulea � ' e a�v . e ada / to CLASSIFICATIONS � 9 � 9 ahould be mount ao as to be acceasible, yet be above easy reach eo as to �,r� �.t B„d � Y , z�a e�w � ai,i yd mnd � 1 � BUILDING OCCUPANCY �2003 IBC� : j THE NEW FlRE ALARM 5YSTEM WILL BE A NO7IFlER AFP-200 ADDRESSABLE FlRE AI.ARM CONTROL provent vandaliam. PANEL WfTH A SEPARAiE SILENT KNIGHT 5401 DIALER. For additional placement restrictions, see NFPA 72 Standards 2002. °i'm °` 4.m °�'" B (SECTION 304) ;'� Firet Band 2� CONSTRUCTION TYPE: � THE SYSTEM WILL BE COMPRISED OF SMOKE DETECTORS, HEAT DEIECfORS, MANUAL PULL NFPA 72 Standards 2002 Second Band SfAiIONS, AIONROR MODULES, COMROL MODULES AND HORN/STROBES. p Third Band Q 3) STORIES: 1 � Per NFPA 7 4.6 Wo�I of�lndlvld'dual�DevEice evice. Fourth Band r ^ � 4) TOTAL SQ . FT. APPROX . 2 ,000 SQ. FT. I A WEATHERPROOF HORN/STFtOBE WILL BE LOCATED ABOVE THE FlRE DEPARTMENT CONNECTION P � � � 1 C� 5� SPRINKLED: YES AND WILL ONLY OPERATE WHEN 1HE AUTOMATIC SPRINKLER SYSTEM IS IN OPERATION. � � JURISDICTION Bottom f Combination THE FlRE ALARM CONTROL PANEL WILL BE LOCATED AT THE HDM/NJCm T1CKEf EMRlWCE AND A See Note �4 AUDIBLE�/ISUAL Device R e s i s t e r C O � O r C o d e C h a rt � � VAIL FIRE & EMERGENCY SERVICES GRAPHIC MAP WfTH A YOU ARE HERE" WILL BE LOCAiED NEXT TO R. Per NFPA .5 or Individual VISUAL Device � 5 �$ 75 FlRE ALARM DEVICES MUST BE PLACED IN PROTECTED AREAS WfTH �� � 42 WEST MEADOW DRIVE AMBIENT TEMPERATURE RANGING FROM 32' TO 120' F. � � VAIL, COLORADO 81657 See Note �5 Top of Devtce � (970� 479 - 2135 � � 0 � � 0 � DO NOT PLACE SMOKE DETECTORS WITHIN 3 FEEf OF AIR SUPPLY � REGISTERS AND DIFFUSERS. � � J/��� NOT Top of Cabinet �� O �' LESS F�P � ALL INTELLIGENT DEVICES SHALL BE INTERCONNECTED AS SHOWN � � ��'°'� . ON THE ONE-UNE DIAGRAM. EACH INTEWGENT DEVICE 'AN� �� Approx. Top of Unit IS DESIGNATED WffN AN ADDRESS. T-TAPPING IS PERMfITED � � 1 BELOW �96 � 7�_p• � � ON SLC LOOP (CLASS 'B' STYLE 4) ONLY. � � � � '�� NO7 •MIN „ (84'� Per NFPA 2-8. 7 WIRE RUNS SHOW INTERCONNECTION OF FlRE ALARM DEVICES ONLY. � �l�,y � �, � TMSS g80� 6 _Q� To Hondle of Device � P . WIRING DOES NOT REPRESENT CONDUIT RUNS. � � �' , 7J (g� F �� �72� 5'-4" •µAX ,� ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR PROPER � � r;� (g4' r�$� � CONNECTION OF EQUIPMENT PROVIDED BY OTHERS. � � � 4' ' (� • M�" , (�� All hei hts measured REMOTE POWER SUPPLY POWER SUPERVISION : � � � �4z�j from (�AF� Above ►--a p �l O Finished FI00� '� (NFPA) NATIONAL FlRE AIARM CODE 72 2002 EDRION T \ � � e� AMBIENT TEMPERATURE RANGING FROM 37 TO 120' F. v � 4.4.7 MONRORING INTEGRfTY OF INSTALLATION CONDUCTORS AND n> � Ty p i c a I D ev i c e M o u n t i n g H e i g h t OTHER SIGNAUNG CHANNELS. ��1 w � 4.4.7.1 .1 - 13 ALL MEANS OF INiERCONNECTING EQUIPMENT, DEVICa, W ~ � � . ■ AND APPUANCES AND WIRING CONNECTIONS SHALL 8E � B � II of Mater � al Sequence of Operation Matrix CONDUCTORSOR EQUNALENT PATH OETHATRTHENOCC RRENCE � � "� � OF A SINGLE OPEN OR A SINGLE GROUND-FAULT CONDRION � Q," � O IN THE INSTALIATION CONDUCTORS OR OTHER SIGWWNG SYSTEM OUTPUT CHANNELS AND THEIR RESTORATION TO NORMAL SFW.L BE �. � A U TOMAl1CALLY IN DI C A T E D W I T H I N 2 0 0 S E C A N D S. � F� IXCEPT. INTERCONNEC'fION BETWEEN ENCLOSURES CONTAINING � � � � N 0. B C O N T R O L E Q U I P M E N T L O C A T E D W f f H I N 2 0 f t (6 m) W H E R E T H E CONDUCTORS ARE INSTNLLED IN CONDUR OR EQUNALENTLY � - PROTECTED AGAINST MECHANICAL INJURY. � AUDIBLE REQUIREMENTS : (REFER TO NFPA 72 CHAPTER 7: SECTION 7.4.2) OP PUBLIC MODE AUDIBLE REQUIREMENTS SECTION 7.4.2. 1 - TO ENSURE THAT AUDIBLE PUBLIC MODE SIGNALS ARE CLEARLY HEARD, THEY SHALL HAVE A SOUND LEVEL AT LEASf �j 15dBA ABOVE AMBIENT SOUND LEVEL OR SdBA ABOVE THE MAXIMUM T � � SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, `_� 01 � WHICHEYER IS GREATER. MEASURm 5ft ( 1 .5m) ABOVE THE FLOOR w : IN THE OCCUPIABLE AREA. � 1/-'-�� I � p 5 NBG - 12L1( MANUAL PULL STATION NOTIFIER m F ROL PANEL TERMINATIONS r � Q I—I ❑d 2 FMM - t MONITOR MODULE NOTIFIER � V 1 w� ELECTRICAL CONiRACTOR I TO COMPLEfE I--I � 1 FDM - 1 DUAL MONITOR MODULE NOTIFIER O TERMINATIONS AT THE FlRE ALARM �dL PANEL. ELECTRICAL � CONTRACTOR SHALL TERMINATE AND LABEL CIRCUITS TO THE TERMINAL � CABINET(S) ABOVE THE FACP. r�^� � � 1 FCM - 1 CONTROL MODULE NOTIFIER � TERMINATIONS AT THE FACP WILL BE COMPLEfED BY A QUAIJFlED w M� � Z CSWC TECHNICIAN. � � w � O �Q 6 P1224MCW HORN/STROBE MULTI-CANDELA NOTIFIER w DRAWING NOTES : � � Q o ALL WIRING RUNS SHOWN ON iHE FlRE ALARM SHOP DRAWINGS ARE ~ � Q� yyp 1 P1224MCK HORN/STROBE MUL71 -CANDELA NOTIFIER F CONCEPTUAL ONLY. THEY DO NOT AND ARE NOT INTENDED TO BE � � � � ACTl1AL WIRE RUNS OR CONDUR RUNS. DEYICE INTERCONNECT IS � � 1 WBB WEATHERPROOF BACK BOX NOTIFIER � INTENDED TO SHOW ONLY SEQUENCE OF DEVICE CONNECTIONS AND w O w � Q lYPE OF WIRE. � ..�.. 1 BY OTHERS WATER FLOW SWITCH BY OTHERS Q PLEASE REVIEW BOTH THE FLOOR PLAN$ AND THE RISER DIAGRAM � � � ORAWINGS TO RESOLVE ANY CONFlJC'i'S OR QUESTIONS THAT MAY � COME UP. IF THE DRAWINGS DO NOT ANSWER YOUR QUESTIONS, PLEASE � � 3 BY OTHERS VALVE TAMPER SWITCH BY OTNERS U �/r CALL CSWC FlRE SYSTD+IS FOR HELP TO ANSWER YOUR QUESTIONS. � � m N M L K J H G F E D C B A SYSTEM INPUT rr PROTECTED PREMISES FIRE ALARM SYSTEMS WIRING : � ►--� � � IDC - Initioting Oevice Circuit � � 1 � � � � � 1 � Manual Stotions, Smoke Detectors, Etc. � 2 2 � � 3 • • � • • 3 �.�• Style B (Clase B) ( w 4 • • • • • • WATER FLOW SWITCH 4 � ` ��Q�e l P P w �-1 5 • • • • VALVE TAMPER SWITCH 5 � � ?.' SLC - Signaling Line Circuit � 6 �R�J �t Intelligent Devices. 2 P • • • • 6 �'' '�Fr» _°„c; . . `, 4 ,., �i � � � • � � 7 nlj�, yW �+ ���� ,.a�:., � . � Style `'TC�Tap) 9) r P z P P � ( I 8 • • • • 8 '�1L'.• - ' � � � 9 -__ _ � - '- . � • • • 9 1 0 b• Z - � NAC - Notification Applianee Circuit � • � � � 10 �.OS- Homs, Belln, Strobes, Etc. 11 � � � � 11 r 1 2 � � 2 Style Y (Claea B) I S � N M L K J H G F E D C B A WIRE CHART �ra runa are indicated by AlphaNumeric designationa. For example: F. A . D . D . DRA WN The wire Gauge of any wire run is determined by the length of the wire run and the power load on that run. CHECKED ,�i - A DATE 9 - 16 - 05 ; ;� ` A typical wire run designated as �A', would rofer to a ` % ' i %�� /%'�� � � � aingle run of '2 {�_ ' cable. i� � C,+ . '� I � i3 ° 10 A. IBANEZ, C➢E.T. Qq SHEET �A � . O F1RE ALARM SYSTEMS/ III A designation of '2A", would refer to a run of "2 # 107370 pair, 2�_ " cable. # OF SHEETS ADpRESS LlST ADD. DEVIr.,E DESCRIP7i0N Li - D Ut PHOTOELECTRIC SMUKE DET. PA55 OFFICE W _� � - L1 -D 02 PHOTOELECTRIC SMOKE DEf. MANAGERS OFfICE � U - D 03 PHOTOELECTRIC SMOKE DET. TICKET OFFICE W� Li --M01 PA�S � � �2 75 L1 �M02 MANAGERS L1 - D 04 PHOTOELECTRIC SMOY.E DEf. OFFICE CHAIR 8 SKIER SER'VICE BUILDING oFF�cE ;�.�� OFFICE �� - o 05 PNOTOEIECTRIC SMOKE OET. AOVANCE TICKETS VAtL RESORTS DEVELOPMENT COMPANY � . _ � _ _ _ _ _= = c _ _ = c =�. = _ _ _ _ = c � O2 p L1 -D 06 PHOTOELECTRIC SMOKE DET. ATS FOREMAN VAIL, COLORADO � L1 -D01 L1 -D02 L1 -D 07 PHOTOELECTRIC SMOKE DET. ATS FOREMAN STORAGE � _ zC L1 -D 08 HEAT DETECTOR OUTDOOR STORAGE � Lt -D 09 HEAT DETEC?OR WOMEN'S REST ROOA� MECH. N1:3 U - D 10 HEAT DETECTOP, MEN'S REST ROOM P P OFFICE STORAGE L1 -D 11 HEAT DETECTOR JANfTOR CLOSET u -MOi L1 -MD'2 � CLOSING SCANNING RM, ATS PASS MANAGERS L1 -D07 AREA KITCNENETTE FORMAN Li -D04 75� FOREMAN U -D 12 SPARE OFFICE . OFFICE 4. Z O P THRU -°---------°-- Up====_=== Op � ---°---------- � � � P - - - -- - Lt-D06 L1 -D01 U -D02 TICKEF ��OP -��-_0-�-5- 2C QOp L1 -D 98 SPARE RM STORAGE � MECH . � OFFICE 2C 15 P P (� L1 -M03 � L1 -M04 N1 :2 � � � � U -M i MANUAL PULL STATION PASS OfFICE NW EXIT CLOSING SCANNING OFPICE ATS AREA KITCHENETTE FORMAN �i -oaa FOREMAN L1 -D07 � � � II II II �'- Li - M 2 MANUAL PULL STATION PASS OFFICE NE EXIT OP ------- L1 -DOB OP Ew•, 4' � C� � �� ADVANCE U -M 3 MANUAL PULI STATION TICKET OFFICE EXIT O F EE �OO P u=oas� � P � g O TICKETS WOMENS MENS Lt -M 4 MANUAL PULL STATiON ADVANCE T1CKETS v p � P 8:5 � E, � L1 -D09 Li -D10 i -MO3 u -n+oa '� ,_ n n STORAGE Li -M S MANUAL PULL STATION STORAGE Ek1T II � � q FACP `., ��� '� O O L1 -M6 DUAL MONITOR MODULE BACKFLOW PREVENTOR G�e, T /� O � 5 � � 5 L1 -M 7 BACKFLOW PREVEMTOR CS CKETS WOMENS MENS � N1 :4 C N1 :5 � � r--y---Li -MD6, ----+ L1 -D09 t.t -D10 L1 -M05 EOLR U -M 8 MONITOR MODULE MAIN WATER FLOW i � 'Lt -MO6 i ❑ P L1 -M 9 MONIYOR MODULE MAIN VALVE TAMPER SWITCH Fnca ' I � � �+ -MO� ; �� Ob � C7 � q q � BACKFLOW � � � Lt -M07 � � � , Lt -D11 DACT I , �, �� -�aoa � � i L1 10 I �O I Li -M 10 CONTROL MODULE OUTSIDE WEATHERPROOF H S M^P � , u -MOS � � � . , i _ U -�.� . Li -M 11 SpARE nf �--'�- -----� n i.i -o� � A � i MAIN � { Q L1 -M0�! I VEST. JANITORi VEST. � LSTORAGE P � �' ; i 0 � THRU LE ND � YOU OO i M N M � Q M L 1 -M 0 9 � 1 E O L R � _`_ J Lt -M 98 S PARE Cia.cP FIREA CONTROL PANEL A R E F.D.C. V E S T. J A N. V E S T. �---- ----== ---------� � �:�A�T con�MU cnTOR HERE o 0 FI R� AL A R M FL OQ R PL A N � P S E T E C T O R w i � N SCALE: 1/8" = 1'-0" NAC CIRCUIT LUMP SUM VOLiAGE DROP CALCULATIONS O+ HE DETECTOR �' � � � .. �. DETAIL NOTES: P�E� iD: FACP (ADVANCE TICKET) CIRCUIT NUMBERS ❑ P UAL PULL STATION A I � � FIELD VERIFY ACTUAL LOCATION OF FIRE DEPARTMENT N O� O CONNE.CTION. LOCATE WATERFLOW HORNlSTROBE srARnNO vOLTACE: 20.4 vDC WIRE SIZE: 14 AwG cKT 1 CKT 2 cKT 3 cKT 4 .�. WATER FLOW SWITCH ABOVE FIRE DEPARTMENT CONNECTION. DENICES CANpEU A1AiS N1 N2 N3 N4 � VALVE TAMPER SWITCH NORN STROBE 13ed 0.116 3 NORN STROBE 30cd 0. 747 I HORN STROBE 75cJ 0,217 2 HORN STR08E WP 110ed 0.288 1 BATTERY CALGULATION FOR fACP SYNC MODULE o.o� � , � UNIT UNIT TOTAL TOTAL Tora_ �ono n�PS ; oF onnces a o 0 o O 1 .208 CIRCUIT AMPS 1 .206 0.000 0.000 0.000 r n Q 4TY. MODEL DESCRIPTIOM SUPV. ALARM SUPV. ALARM ciacuR �ricn+ (esnM�ho) zoo v 1 � 1 AFF - 200 FIRE ALARM CONTROL PANEL 0. 10000 0. 10000 0 . 10000 0 . 10000 ""ACTUAL VOLTAOE DROP ('VOLTS) � .�e� o.000 o.000 o.000 I > > � _ I �1 � 1 SK - 5104 DACT 0. 05000 U. f 3500 U.05U00 0 , 13500 END 0� UNE YOLTACE 18.919 20.400 20.100 20.4C0 I 7 FSP - 851 PHOTOELECTRIC SMOKE DETECTOR 0. 00036 U.00036 0. 00252 O.U0252 MAXINIAA ALLOWABLE DISTANCE ssa o 0 o GRAPHIC AMP N.� � 4 FST- 851 HEAT DETECTOR 0. 00030 0.00030 C�.00120 0 .00120 CALCULATION FORMULAS SCALE: 1^ = r a � 5 NBG- 12Lk MANUAL PULL STATION 0.00038 0.00038 0.00188 0.00188 ACTUAL VQ�TAOE DROP ■ (CIRCUIi tENCiTH X 2) x (A1AP3 X OHMS/FT) � � 2 FMM - 1 MONITOR MQDULE 0.00038 0. 00038 Q.00075 O.00O7S MA%IMUM DISTANCE � (4.4 V / (AMPS X OHMS/F'f) / 2 1 FDM DUAL MONITOR IdODULE 0.00075 0.00075 0 .00075 0.00075 END OF LINE VOLiAOE _ (CIRCUR LENGTH X 2) X (AMPS X ONMS/FT) - 20.4 V H ^1 1 FCM - 1 CONTROL MODULE 0.00038 0. 00038 0.00038 0.00038 T� � q7 0 3 P122AMCW FFORN STR08E 15 CANDELA 0.00000 0. 11600 Q.OD000 0.34800 r�e� a NEC) STROBES 8c s�zE oN►�s Fr HORN/STROBES w � � 1 P1224MCW HORN/StROBE (30 CANDELA 0 .00000 0. 14700 0. 00400 0. 14700 � 2 o.00i9a r---�-� �„r 2 P1224MCW HORN STROBE 75 CANDELA 0 . 00000 0.21700 0 . 00000 0. 43400 t4 0.0030� I I p..� � � e o.004ea SMOKE OET. � � � 1 P1224MCK HORN STROBE 110 CANDELA WEATMERPR�OOF 0.00000 0. 26600 0.00000 0. 26600 TO TO 1 MDL SYNCHRONIZATION MODULE 0.00000 0.01100 0. �0000 0 01100 te o.00m HEAT DET. NOTES: MMO ULEC s D C 04 MAN . PULL STATIONS � Q' O O .00OOO O .00OOO O .00OOO O .00OOO 1 . wMP 3UM �,►ro sr�rmwc vou,�cE � soos r�c�a-n �uNUeoou, ��� �_, � I � � O TOTAL 0. 15747 1 .44847 secnoN �.a.2.�, uup�� u�u ui.4sa. q S U P E R V I S O R Y X 2 4 H O U R S 3.77 9 2 8 z. ACTUAL VOLTAGE DROP SHALL NOT BE MORE TNAN 4.4 VOLTS. DEVICE ADDRESS 3. END OF LINE VOITACE SHALL NOi BE l,ESS THAN 16.0 VOLTS. I�.UX. Power In d ica t ing�50�. S�p� Alarm Trouble EIA-485 $�C l � � � Q AIARM X 5 MINUTES 0. 12071 CLEAR TAPE W/BLACK LETTERING � � � � II � 1 � G2cuiis 4 IlRelaylRelaylRelayl I I I I I Loop I �"'� O w � TOTAL STANDBY REQ�IIRED 3.69999 BY ELECTRICAL CONTRACTOR +24V +24Y +24V 4 4 I �,.,� Q' '�, 2 �A n E R I E S S U P P L I E D A R E 7 A H _ �i I FROM FACP HORN CONTROL O + 4 eEU- + ea� z eru s �u 4 r ��-23z _ _ �o s�c O � r, O � _ ; _ ; _ !+ Y- N !- B+ !- i !- !q NC C NO NC C 7% REF RX REF A 9 !i Ai B- M ��`I FROM FACP 5fROBE CONTROL � 000000 00000000 0 0 0000 0000 000000 w !� � M � O � �'^ O O N1 : 1 N1 : 2 N1 :3 N1 : 4 N1 :5 N1 :6 30 75 15 75 15 15 w,, ,,,,, O 0 O O O ,�� o � �7 � �3 0 0 0 � �5 TB6 � � Q� � •r�,i C -�- G --�- C C --�- C --� EOLR t� � � � Q 8 7 6 S 4 3 2 1 J P 6 )) � �` V�J� � � g x. a x. t e�rr �. l�l�T PWR O SET TO O C� � � EOQ " O � � ACS � t� � � � � � �� �jABOVE F.D.C. • e �n-p�c �c�y ����� � O � i � L1 -MO6 =�� _�£ � �£ � � Lt -M10 Lt -M09 Lt -M08 L1 -M07 Lt -Mp5 1Lt - M04 Lt -M03 Li -M02 Li - MOi p 18 13 14 13 t2 17 �o .e p A M A M A A -�P A P A --�_`r- A -�--�r- A --�r A -- O O O O � � � � \ p,�� ,p,c i'M r- P EOLR E6LR ; ` . ' JP2 � A2C D3 � NORMAL � � ` li'-I1 , . �; ...__. � �,� ,� �� ,�.J�./ L����''r� � TO HORN/STROBE & STROBES � � . �; I �r`� Ala �� � I NAC (� TO NqC (V) FROIA G t J L M : Z DA; ! � � F�,C� -- 1 Lt - D '� L1 - DG4 Li - D05 C1 - DU6 U -UUi U �- p08 Lt - D09 l, 1 - D10 L1 - Dil I NE)(T DEYICE PREVIQUS DEVICE 4 S 6 : F�+1 r- L '-"-' A -{2 '� A - 2� P-- A �P A --P- A --�P- p -{P A --�}P A ---a- A -- --{j�- A --U- A -�- A -� OR 47K EOLR M DL SYNC MODULE ; Q I r , P1224MC H/S � $ 9 ' � � � 120VAC ONE LINE DIAGRAM • * O �• O FIREP�ER ACKNOWLEDOP � . O �j EM PWR SCALE: NONE � �R� , w h..i NSEXT DE�NCE PREVIOU SDEVICE FROMSPRtVIOUS SLC + (A) O PRE-ALARIA ��►RM � r.� � DEVECE ADDRESS DEVICE TO NEXT DEVICE WARNIN6 SII.ENCE O CLEAR TAPE W/BLACK LETTERING F•i•� BY ELECTRICAL C014TRACTOR O SUPERVISORY DRILL � � JPS � � � AuRM wan : xoaw �' NI 2 O � ENTER � � SIIENCE �j � Mi C� � � O SYSTEM SRESET � W O WIRE SGHEDULE � � O O AC POWER TRQ�� O -' a � • DEVICE ADDRESS B� � C�CWT � � DESIfiNATION CI UIT 1YPE � TYPE YIIR� COLOR �� o CLEAR TAPE W/BLACK LETTERING 3 1 BREAKER � � A SLC LOOP (2) �16 SQLID RED (POS.), BLACI( (NEG.) BY ELECTRICAL COPITRACTOR CB' �T� EPROM W AC 120VAC PANEI POMfER (3) �12 SQLID GREkTI, BUGK, 4YHl�E I [I� f W a C NOTIFICATION CIRCUIT (2) �14 SpLID ORANGE (POS.), BRQWN (NEG.) � � H HORN CIRCUfi (2) �14 SOLID RED (POS.), BLACK (NEG.) SLC - (A) ���' SLC - (A) � �, � �JP1 t��l � S STROBE CIRCUR (2) �14 SOLID PINK (POS.), BLUE (NEGJ � o f� 0 0 � OO � CROUNp � 0 OO i°z+ fROM PREVIOUS TO ND(T � �n ■ o � F,w�r O � D DACT COMM (2} �!1 & SOLID ORANGE (POS.), BROWN (NEG.) U o�o �„ �oT euzz� �s �!1 � P 24VDC (2} �f14 SOUD RED (POS.), BLACK (NE,G.), ORANGE, BRQWN DEVICE DEVICE cawnar Nia� var� TRANSFORMERJVOIT AMP � "�9 � � Z INITIATING CIRCUIT (2) �f16 SOLID RED (POS.), BLACK (NER3.) B710LP DETECTOR BASE � \ O� � NOiE: 1 . NO T-TAPPING PERMRTED ON NAC NOR IDC CIRCUITS (COMMON ARFA SMK & HEAT DET.) 0 tional Opfional r� NBG-12LX MANUAL PULL STATION vo�tmeter Amrr►eter NATIONAL ELECTRiCAL COQE Connection Connection � f+•� rns� �so-�i (n). ( CABLE MARKlNGS � � CABLE MARIKING TYPE USTMIG REF'ERENCES r �`� �. r-. �"� FPLP POWER-LIMITED fIRE ALARM SEGTIONS 760-71 b AND h PLENUM CABLE � � O O � � _ _ �PLR POWER-LIMIIED FlRE ALARM SEGTIONS 760-�1 (e) AND jh) r _ � � O O � �� � O O � � 12YDC + 12VDC + �� �qg� O � BATTERY BATTERY FPL POWER-LIMViED FIRE ALARM SECTIONS 760-�1(g) AND (h) 9 +ia � ��+� � � O � TO � � 9 � �� O CABLE TO WP 8 D�' +2 . SLG �A� iDC Z e HORN�$TROBE NAC C 7 � � TO MAJN $ ' �s 2 SLC (A) PREVENTOR 7 '�' z SLC (A} AFP'�LOO FPLP SHALI, BE USED IN PLENUM CEILINGS. EOLR � � + s' 3 : FLOW & VALVE �p� �Z� " � � EOLR �� �Z� 7°a FPIR SHAII BE USEO WHEN PASSING THROUGH FLOORS. ABOVE F.D.G. � zawc (P) TAMPER SWC(CHES ` 6 ;�, 3 ' 6' ' 3 FIRE ALARM CONTROL RANEL D� p�N F.A . D. D. FPL SWILL 8E USEp ONLY IN NON-PLfNUM AREAS. � ° +4 ' 1 EACH 5 � 4 4 �s �o a s EQ� a„a ,,,,, CHECKED �l O O l�' Q O O !�' Q O O � DATE 9- 16 - 05 FMM-1 M NITOR M D LE FDM-1 DUAL MONITOR MODULE � �' �3��s SHEET FA2 . O �CM- 1 C�NTROL MODULE � O O U �io A. IBANEZ, E.r. IRE ALARM SYSTEMS/ III J � J ,�, o�a�o � o� .�J .✓-J SHE'ETS