Loading...
HomeMy WebLinkAboutLodge at Vail Unit 530a.l TOWN OF VAIL 75 S.FRONTAGEROAD VAIL, CO 81657 970-479-2t38 DEPARTMENT OF COMMI.JNITY DEVELOPMENT **\Q;L\oftto L"t46---\-O5a\() NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALTMFBUILDPERMIT Permit #: 807-0269 (u- -64(5- Project #: ?? Job Address.: 174 GORE CREEK DR VAIL Location......: THE LODGE APT CONDOS #530 ParcelNo....: 210108221074??sor 'afi ohrNER TYTEL, HOWARD & SANDRA 08/17/2007 1OO OYSTER BAY RD MILLNECK Nv 11755 APPLICANT BECK BUILDING COMPANY 08/17/2007 phone: 970-949-1800 P.O. BOX 4030 VAILco 8L658 License: 117 -A CONTRACTOR BECK BUILDTNG COMPANY 08/77/2007 Phone: 97O-949-L8O0 P.O. BOX 4030 VAIIJ co 81658 License : l-l-7 -A Desciption: INTERIOR TRIM, STAIR TREADS AND RISERS, PLUMBING FIXTURES, ELECTRICAL FXTURES. PAINTING AND CARPET Occupancy: Type Construction: Valuation: $50,000.00 Revision Valuation: ?? Total Sq Ft Added: 0 *:l 't t,|,t** **'l'| *a*:l* Building--> 9643 . ?5 Restuarsnt Plan Revi€w-> So . 00 Total Calculated Fees-> 91, 065 . 19 Plan Check-> $418.44 R€crealion F€€-t $O.OO Addilional Fees--.--> $0.00 tnvestigalion-> 50.00 TOTAL FEES - > $1,065.19 Toial Permit F€e-> S1,05s.19 Willcall-> 93.00 Payments > 91,05s.19 BALANCE DUE-> 50.00 +r lralt*t *:l* * * *t i + + * f * l * ll a'l *t *'l *:* Approvals:. Item: 05100 BUII-,,DING DEPARTMENT 08/t7/2007 jplano Action: AP Item: 05400 PL,ANNING DEPARTMENT 08/17 /2007 warren Action: AP Status.....: ISSUED Applied...: 08/17/2007 Issued ...: 0E/20/2007 Expires...: 02/16/2008 See Conditions page of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is conect. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this stucture according to the towns zoning and subdivision codes, desigr review approved, Intemational Building and Residential Codes and other ordinances of the Town applicable thereto. NEQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOT'R EOT,RSI tN ADVANC 4 PM. EPf,ONE AT 479.2t49 ouR orT'rcE InoM &00 AM. SIGNATIJRE OF OWNER FOR HIMSELF AND OWNER Ir ****'|*+*'|+!i+++'|t**'i**'**:*'|'|,|''|,|'*'*:t,}:|t*'}*****{'t*'t+*****i******{t't,}'t'},}{.'}'|l'}*'}'t***'}||** Permit#: 807-0269 CONDITIONS OF APPROVAL as of08-20-2007 Status: ISSUED ****+*'|*+'+'|+*+**'t'}****'|l'{''|''t,}'}:|''|,t*'}'}**'.''t'l*'|'}*+++****i********'|***lt*'t*'t'}**'|t{t,|{t{ti**'**'|*'t**+*************** Permit Type: ADD/ALT MF BUILD PERMIT Applicant BECK BUILDING COMPANY 970-949-1800 Job Address: 174 GORE CREEK DRVAIL Location: TI{E LODGE APT CONDOS #530 ParcefNo: 210108221074 Description: INTERIOR TRIM, STAIR TREADS AND RISERS, PLUMBING FIXTURES, ELECTRICAL FXTURES. PAINTING AND CARPET Applied: 08117/2007 Issued: OE/20/2007 To Expire: 02/16/2008 ****** *********!F** 't**** * **{"t'}'t**** ***** * * * ** ***Conditions.:1.**'lr'* 'i '1.,1.:* *!*{r '}'}:lr*** **** *** ** * * *** ** dr'*** {. * '* '}'}'1.* Cond: l2 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLTANCE. Cond: l4 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: I (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE AI.TY WORKCANBE STARTED. Cond:40 (BLDG): (MFR/COMM) FIRE ALARM REQUIRED PERNFPA 72. APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR F VAIL LDING Separate Permits are requi e plumbing, mechanical, etc.! GONTRACTOR I N FORMATION -s Vail. Colorado 81657 Bo?.oaag'ffi PLICATION Qro-Q..tQ - \go own of Vail Reg, No.:riuit, hbn\c COMPLETE VALUATIONS FOR BUILDING PERMIT & Materials BUTLDTNG:$ 114,000 -ELECTRICAL: S bO) -OTHER: $ PLUMBTNG:$5000-MECHANICAL,$ 6d)'TorAL: g 50,000 - For Parcel # Contact il""E.S%ffiA' 'F*^\or visit Fi*Hls zl o I b$ zzlo-1{n U JobName: Tltt\ fl.trnodc \TOWN OF y61gro.;-*,to'ot, ftiu H f' $; grc Lr'l* Legal Description Lot:Block:Filing:subdivision: l,odftt Ap+ 6ndou*j.l owners Nuru,4n,nd,f TU ft Address: 100 eskr BAl,f lQ ,tvlitlNtcb,Nt Phone:911r- be{_ 0tzO ArchitecuDesisn"'l fimr DirJ. nrcl Address:pg6o {1zc). Auo'n,[-o B||,brr, ll "non"'rt1D- qq-?bz Engineer: l.t | 0 Address:Phone: ry- , t'rk.Tr irvt ,6ttk 'trcads lf\eu<, Ptun^h,v5 fi$.;ra< ,E\ccR'*t.rrrs, Pninhvul , t\xoc* ' ' WorkClass: New() Addition( ) nemoOel t{) Repair( ) Demo( ) Other( ) Work Type: Interior fi) Exterior ( ) Both ( )Does an EHU exist at this location: Yes ( ) No (X) Type of Bldg.: Single-family ( ) Twojamily ( ) Multi-family 1l; Commercial () Restaurant ( ) Other ( ) No. of Existing Dwelling Units in this building:No. of Accommodation Units in this building: No/Type of Fireplaces Existing: Gas Appliances ( ) Gas t-ogs /) Wood/Pellql{ ) Wgod Burning ( No/Tvpe of Fireplaces Proposed: Gas Appliances ( ) Gas Logs ( ) Wood/Pellet ( ) Wqod Burninq (NOT ALL Does a Fire Alarm Exist: Yes ( ) No (Does a Fire Sprinkler System Exist: Yes fi) No ( *********************************#******t*FOR OFFICE USE ONLY*****s*t**t*rr*********:r**+H:l**i***!r:}************.* V r a€5.5 http://www.vailgov.com/docs/dl-forms/buildinqjermit-+17-2007.DOC Page 1 of 7 041t712007 li NinaTimm Housing Coordinator Town of Vail Town of Vail OFFICE COPY May 16,2007 Howard and Sandra Tytel 100 Oyster Bay Road Millneck, NY I1765 Dear Mr. and Mrs. Tytel, Enclosed you will find a 'till" for your employee housing requirement under the Town of Vail's inclusionary zoning ordinance. Copies of the ordinance as well as the associated resolution have also been included. Additionally, a copy ofthe Design Review Board Action Form has been included for your project. It states that *all development applications submitted to the Town after the effective date of Ordinnce26, Series 2006 shall be subject to the pending employee housing regulations in whatever form they are finally adopted." The Vail Town Council unanimously adopted Ordinance 8, Series 2007 onApril3,2007. Payment of the fee-in-lieu is required prior to the issuance of a Certificate of Occupancy for the project Ifyou have any questions please feel free to contact me at970/479-2144. Sincerely, , tt Ff*.n'#iipy Tytel Interior Conversion Legal Description: Lot A, the Lodge Apt. Condominiums DRB 07-0005 I. Net New GRFA for Tytel Residence A. Residential Increase: Inclusionary Zoning Increase in GRFA : I 10 sq fi increase Inclusionary Zoning requirement = 10 percent ofnet new residential sq ft 110 sq ft x l0 o/o: 1l sq ft required deed restricted employee housing B. Possible Method of Mitigation for Inclusionary Zonng 1. Fee-in-Lieu i. Provide a fee-inlieu payl.ent to ths Town of Vail of I I sq ft x $236.65 / sq ft: $2,603.15 II. Payment of the Fee'in-Lieu A. Payment of the fee-inlieu of $2,603.15 must be made prior to the final inspections for the addition TOWN OF VAIL DEPARTMENT OF COMMUNITY DEVELOPMENT 75 S.FRONTAGEROAD VAIL. CO 816s7 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT MF BUILD PERMIT PETMit #: BO7-0015 hoject#: ?'fpR: O-l -oooF Job Address.: 174 GORE CREEK DR VAIL Status.....: ISSUED [,ocation......: THE LODGE AIrI CONDOS #530 Applied...: 0210812W7 Parcel No....: 210108221074 Issued ...: 03/Ul2m7 Expires...: Ogl29l2W7 olrtNER TYTEL, HOWARD & SANDRA 02/O8/2OO7 1OO OYSTER BAY RD MIIJIJNECK NY LT755 ARCHITECT I-,ARRY DECKARD, ARCHITECT 02/08/2007 PhONC: 970.559-3102 PO BOX 725 AVON co 8l_620 License: C000001796 APPLICAIiM WALKER BUILDING COMPANY 02/08/2OO7 PhONC: 970-328-9362 1"052 MESA DRIVE P.O. BOX r-r.38 EAGI,Eco 81531License: 882 -B CoMRACTOR WATTKER BUILDTNG COMPAI{Y 02/Oe/20O7 Phone: 970-328-9362 1052 MESA DRIVE P.O. BOX 1138 EAGI,Eco 81631 I-,icense: 882-B Desciption: ADD ONE EXTERIOR WINDOW AND DOOR AT WEST ELEVATION AND IlO SQ FT OF GRFA IN LIVING ROOM TO MAKE INTO MASTER BATH Occupancy: R2 Rl TypeConstruction: III-A Valuation: $178,000.00 Revision Valuation: ?? Total Sq Ft Added: 0 Investigation- > will cdl----- > so. oo ToTAL FEES------------- > $3.00 Building----> 51,430.55 Res$arant Plan Review->PlanCheck--> i929.85 Recreation Fee-------- > FEE SUMMARY :i,t'hr*:tr.'i**.t****:******{.****'l.a**r*****!.d,:t*:r:1.:r+,i:F**,},**,****'***{.** S0 . 00 Toal Calculated Fees- > S2 , 363 .41 $0-00 Additional Fees----- > 50.00$2,363.41 Total Permit Fee----- > $2,363.41 Paynents-----------..- > 52,363 -4I BALANCE DUE--------- >s0.00 Approvals:Item: 05100 BUILDING DEPARTMENT o3/o2/20o7 JRNL Action: AP ftem: 05400 PIJANNING DEPARTMENT 02/08/2007 warren Action: AP Elevations of the remodel not included. The elevati-ons shall be reconstructed per the approved DRB application. Iten: 05500 PIRB DEPARTI{ENT Item: 05500 PITBLIC woRKS See Conditions page of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge ttnt I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to cornply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this stnrcture according to the towns zoning ard subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQTJESTS F1OR INSPECTION SHALL BE MADE TWENTY.FOUR IIOTJRS IN ADVAI\ICE BY TELEPTIONE AT {I92I49 AM-4PM. ORCONTRACTOR FOR HIMSELF AND OWNEF '**:*****!**'f *******i(*******!t,t'*'*'t!*'t******1.***!t**'r't****************'t*'t******!*****'+{r**'l***'k**!t***:r*'+:lr'lr:*,***!8** CONDITIONS OF APPROVAL Permit#: 807-0015 a6ofO3-U2-ZUJ7 Status: APPROVED {.'f*'|.**'r!N:f't*{.i****'t*************!t*{.**{.{<{.*1.*****'t**,|t'F'i't**'N*,t't**:F*,}*t***:t***,t*******'|*'}'F'|!*:|.******** Permit Type: ADD/ALT MF BIJILD PERMIT Applied: A2l08l2m7 Applicant: WALKER BIIILDING COMPANY Issued:nU328-9362 To Expire: Job Address: 174 GORE CREEK DR VAIL location: THE LODGE APT CONDOS #530 Parcel No: 210108221W4 Description: ADD ONE EXTERIOR WINDOW AND DOOR AT WEST ELEVATION AND 110 SQ FT OF GRFA IN LMNG ROOM TO MAKE INTO MASTER BATH *****1.***r(:r***********,t{.'lr*:tr********************conditions, {.!r:ir.**:***{.********:*r.'t***********'1.*{r********** Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cord:14 (BLDG.): ALL PENETRATIONS IN WALLS, CEILINGS, AND FLOORS TO BE SEALED WITH AN APPROVED FIRE MATERIAL. Cond: I (FIRE): FIRE DEPARTMENT APPROVAL IS REQI.NRED BEFORE ANY WORK CAN BE STARTED. Cord:,() (BLDG): (MFR/COMM) FIRE ALARM REQLIRED PER NFPA 72. Mu{ APPLICATION vv|LL NOT BE ACCEPTED IF INCOMPLETE OR UNSI L Separate are required for ng, mechanical, etc.l Project #: F:ltCine-F,e 75 S. Frontage Rd. Vail, Colorado 81657 CONTRACTOR INFORMATION COMPLETE VALUATIONS FOR BUILDING PERMIT BUILDING: $ For Parcel # Contact Assessorc Otrice at 970-328-8640 or visit WorkClass: New() Addition( ) Remodet |fl Repair( ) Demo( ) Other( ) WorkType: Interior( ) Exterior( ) Both Does an EHU exist at this location: Yes ( ) No Type of Bldg.: single'family ( ) Two-famity ( ) Mutti-tumity ff commerciat ( ) Restaurant ( ) other( ) No. of Existing Dwelling Units in this building:No. of Accommodation Units in this building: GasAppliances( ) GasLoqs( ) Wood/Pellet( ) Wood : Gas Appliances ( ) Gas Loss ( ) Wood/Pellet ( ) Wood Burninq (NOT ALLOWED FOR OFFICE USE ONLY F:\devwRtvls\Permib\Building\buildrU_.f rntt.DOC il \v/ t5 200t _VAILOF lfi) E-G /'1/ FEB Towrv 0awa0f5Ege r of 16 ..€. RocrRssonrs January 4,2007 Mrs. Sandra Tytel 174 E. Gore Creek fhive Vail CO 81658 Dear Mrs. Tytel: The Board of Managers for Lodge Apartrnent Condominium Association has received your request to remodel your condominium. The construction will include the following projects: 1. Remodel the entire kitchen. 2. Remove all flooring and replace. 3. Remove all bathroom fixtures and replace. 4. Moving walls to facilitate bathroom remodels. 5. Additional ll0 square feet offloor space. 6. Electrical upgrades. 7. Replacement of all windows to match existing. 8. Addition ofa window and reconfiguration ofthe balcony door. Subject to the following conditions the Board of Managers hereby approves of the proposed plans: l. An approved condominium construction document is signed and all conditions are adhered to.2. All required permits are obtained from the Town of Vail. We wish you well in your endeavor. Sincerely, \/zvo V. Charles Viola Managing Agent Lodge Apartraent Condominium Association 174 East Gore Creek Drive. Vail, Colorado 81657, USA Telephone (970) 476-5011 Facsimile (970) 476-7425 www.rockresorts.com %fu: oa(ff.ffirY ElEInFr€ir Design Review Board ACTION FORM Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 lax'. 97O.479,2457 web: www.vailgov,corn Project Name: TYTEL RES. ADDffiON Project Description: Pafticipants: Project Address: Legal DescripUon: Parcel Number: Comments: Location: THE LODGEAPTCONDOS #530 LODGE AFr CONDO (THE) DRB Number: DR8070005 Request for an interior conversion of 110 square feet. Includes the addition of one new window and a window to be replaced by a french door. OWNER TYTEL, HOWARD & SANDM OIIOBI2OOT 1OO OYSTER BAY RD MILLNECK NY 11765 APPLICANT WALKER BUILDING COMPANY OUO8|ZOO7 Phone: 970-328-9362 1052 MESA DRIVE P.O. BOX 1138 EAGLE co 81631 License: 882-8 CONTMCTOR WALKER BUILDING COMPANY 0t10812007 Phone: 970-328-9362 1052 MESA DRIVE P.O. BOX 1138 EAGLE co 81631 License: 882-8 174 GORE CREEK DR VAIL Lot A Block Subdivision: 2LOL482-2|074 See Condiitons Motion By: Second By: Vote: Gonditions: BOARD/STAFF ACTION ACtiON: STAFFAPR Date of Approval: 01/10/2007 Cond:8 (n qN): No changes to these plans may be made without the written consent of Town of Vdil staff and/or the appropriate review mmmittee(s). Cond:0 (P|-AN): DRB approval does not constitute a permit for building. Please consult with Town of Vall Building personnel prior to construction activities. Cond: 201 "i ol DRB approval shall not become valid for 20 days following the date of approval.'Cond: 202 Approval of this proJect shall lapse and become void one (1) year following the date of final approval, unless a building permit is issued and construcflon is commenced and is diligenfly punued toward completion. Cond: 113 All dwelopment applicaUons submitted to the Town after the effectit/e date of Ordinance 26, Series 2006 shall be subject to the pending employee housing regulations in whatener form they arc flnally adopted; provided, howaner, that if the Town fails b adopt the pending employee housing regulations by April 75,2007, this Ordinance shall not apply to sudr development applicatlons. @nd: CON0008619 The applicant shall reconsbuct the o<terior of the building In a manner which does make it evident where windows were removed or added. This may entail replacing more siding than just patching locations where windows were removed. Under no circumstance should it be distingulshable were old and new materials meet. @nd: CONffi08520 The applicant shall makh all windows, dmrs, siding, and colors to those o<isting 'cunently on the structure. Ptanner: Wanen Campbell onS ree paii: g3oo.oo gLl8612g67 il: el 5L69222748 ..F ".tgn ti4 oz oa:asp 61ry g' welk* PAGE €I 9?0 328 70{6 P,z *ffi Addltions-RecHential or Conmetcial Appllcation for Decftln Review rErnmefit of &ilm'nq DetteloFtr|ert zs soin Fontage nor4 \r.1, Colorab 81657 tck gtoftgJtlE * 970-479'2f9 rdt rflil.n[gsYcoftt G.nar.l DtlbnFauolG Al Ororrct3 rquirttg ddgn t€lrrcr mld r€elE 4rord P|fr to $ht|thg a br$tng Arnit npdiefen' Plese rrE to ti-s-ri:umiuf--rhurtmris O rnc pl,ira|ar rpiinar d* is t€qresllrt' -rn fdicaton tsroElgt .RtF Gff+-I *idJ u"tr 6f,-1aqr1g rnnormaUq, s rccEtt d Dry 6c Consnunni oet1g6p?tpnt D.perttplt' Th' goln maY cro nGed iid'circ;brt[ra,"c",ffi;;4#ltaEni"rs-rrl'illlu;r'r"mt-qryg-11g1151'Prtlt'dl'pc'l;"Hil;iLfi;F'fri ;" *r.d eicorur..trrn connrqrccr rltrn qrc v*d tlr.prrc1a1 tiqrtption of t'he RcquctG Locrtlon of the f)l!Pos* Lot!--Bl6k:- SuHMslf|: phr*drdd,*ra: /?u f<<+f. r t 2.*Ah,;/6a' 8' 1- parcef ilo.! HhlOSTl tOZy.- (coilrct E eh co. r5scsorrt e F32E€5{o til oarel no') Zoolng: ilrm{r} of olrnc(i): ilallingtdll]erc Orrmrtc) Sign tr€(s): ilame of Applhantr r*.iltng Add]Esi: E-rnafl Addr.s6: . )hcfrypGof Rdicn-dtr Signs l$ Plllsfl.m prqtarclbotdtotrldgn ft1 No FeeCo(rFdnel,hr ileflCooruudrt Adddar t{nor Abnrgon (multi{r milyrcomnHci.l) lftorAbattor (ningbhnily/dudcO ChrrErs b Afrovcd Plans s€fandoo R*ucd lEsotxlo s250 tr tr F o For @1$uc0m of r flsf ltttdhg or derm/r€hld. For an ddison wherc rquaE foo@e ls adfu b rny rc$tlenthl or conmadal ilflding fn fiftt 250 addltirs e itmlta csw.erdons] For mlnor dlragca tr arflngE and Ctr imF6rEms,rts, $ch .s, rgrbofhe, Finting, wlt|(bt, Udfions, lan6caplng, ftnes and tttnning wall+ !tc. for nrr,oi aarEcr b hffhos ard rfte impov:nrcnb, s-dr s, r€-mof/qg, gdnrrg, wtr*nr .ddto|q la&caplng, tiaas and nithingt20 o o wollt !tr.3:10 hr rcrtlons b pb|E dre.dy rppro,ed by nanning Sldlt or tie DrCannrr,h{ld.ib Fr tue ftittl -i-- chcdr ts.:- ey:t ASBESTOS TESTTNG REQUTREMENTS THE TOWN OF VAIL AND SrATE OF COLOMDO DEPARTMENT OF PUBUC HEALTH REQUTRE ASBESTOS TESnNG ANY TIME WHEN MORE THAN 160 S.F. OF MATERIAL vyILL BE DISTURBED OR REMOVED. AN ASBESTOS TEST AND REPORT IS REQUIRED TO BE SUBMITTED WITH YOUR BUILDING PERMIT APPUCATION FOR ALL REMODEL ADDMON OR OTHER PROJECTS INVOLVING ANY DEMOUTION OR REMOVAL OF BUILDING MATERI.ALS THAT MAY CONTAIN ASBESTOS. BUITDINGS CONSTRUCTED AFTER OCTOBER 12, 1988 THAT HAVE NO ASBESTOS CONTAINING MATERI,ALS ARE EffMPT. A COPY OF fiE REPORT MUST BE SUBMTTTED VVTH YOUR BUILDING PERMII- APPLICA]ION o I have included the asbestos test and report with my building permit applicauon o I certifo my project will not disturb or remove more than 160 s.f. of building plans submitted with my application clearly indicate this information. (t-his will review, and will delay your project if found to be inaccurate) material. The construction be verified during plan applicant signabrre OR date o The building was constructed after October 12, 1988. The date of construction was original @nstsuction date applicant ggnatire F:\cdev\FORMS\FenniE\BUlldng\bulldngJremit. DOC date Page 4 of 16 021o}.12005 llEC I t 2OOB l1:29R]{ BOULDER EilvIROltl{ElrTRL r (966) 699-+121 p.3 MMht Boulder Environmentel Management, Inc,' SDc.rTtrilndDorldcr,GOlB@ Ptore Sm;a91115 Frr: t ([6Q691]{(ll Deccmbcrll,Zlx|6 Watkcr Building Company Mr. Gay Walker P,O. Box ll3t Eagle, CO 81631 RE: Bnlksanplingofsuspcrfeita$estos-cominingmanrials Thc Lodge ar Veil, Udl53& Ydl Cclorrdo DerMr. Walker: Attactred is tp report for lhe asbcstos survey md bulk rynpling of suspecEd asbestos- conainingbuildiry mEterisls atThLodgc rtVd[ Itria 53O,Yrfl Cobrrdo This iwtstigatimwas coducted onbebalf of nd for tre enchsive use of Stdkcr Building Conpruy (clieol), solely fsrxe ina limited asbcstos srwy of thcpropty. ThirEportudtbe findflnphcrehqhdr pg inq,ho! uinpa! bc dis*minedc convqpdio ay othcr party, mr uscrl by my other pa'ty, inu,*rolc or in part without prior writta crrcent of Bortdcr Environmcnlal ManagcncnL Thc rcmlfs ofrlri-r srlwy sp lini1ql15 neqidrrh4 wrc rersablc end fucseeablo. Additionelmmials may ais bchind bsd sufrccs Prtsmd knowlcdgcable of asbeos cutaining maerids should alwayr ovprsce dcmolitiq activitics. Danolitim u,ork shild bc bttod and rqling pafrmrcd by a crtc of Cohndo licosd hrildiryiryclor if additional rrafcridA wldrfi arc nxpctcd of oontaining asbcOq re reotmered- If you havc any $rctiu reguding ts conte"rfs of tis rcporq plcrre do ld biEe to conlact us- SiFEly, C,L/I Cluis Maron nojctMnrgcr *ArbcrtorrldrlEdufhf llyEi.ocrSdcty.Find Air TcrtingrrHcdil end $fcty Tnldlg. DEC II 2OOG ll:29R]'l EOULIIER EllvIRONllEltTRL I (AGCI 599-.+l2l Boulder Environmental Management Inc. 5Ih€rTrail RodBonl&, CO t03@ PhodE: (303)'14$1175 Fn; t (166)699{12l BULKSAIUIPLINGREPORT Thc tadgc et VrL Unft $q Yril Cebrrdo Iniroductirn: On Deceobcr 5, 2m6, Boulder Envimnmcubl Umagpmcnt, Inc.'s building inryector, Cra[ Rcu" coducned bulk samnling of srsueed asbagtos.oonfid4ips naEriEls tmder tbe diredion ofour clie,nt. SenpEng: Duing the sampling Flocess, srspcct ACM was scporaed info three EPA categorics.Tb c*egodo are thcrmal systcm insulaion (TSI), srrfacirg ACIIA ad mirccllmeous ACM. TSI incMes all rqahrirls us€d to trevcd H los c g8in or xlalcr cofusrtion on rchurical syseins. Bxmptcs of TSI re pipe mvcrbgs, boiler insulatioo, dnct wrry, d mud pacted fining mcot Surfrcing ACM inchdes all ACM thst is sprayed, trurcll€d, or othaurise applicd to a slufacc. Tbcr rpplicnbns rre most commonly used in fingoofiag, dccoriati\re ad ror(ical Aplicdios. lvfisccUroeous dcrhh imlud€ all ACMmt li#d in trcthermd sysEn insul*ion ote!ficiagcategorieg such as linolan, viryl asbcstoc flociry rrd criling tilc. Boildtr Envftomcolal },fasgEetd, Ioc- folloxrcd EPA rtcqrcded qlhg guidclincs for identification of asbcstm in bulk nroiccs. A sst of th,cc (3), ftrc (5), or scvco (l) sanples nqe collc@d fcerch nmiel typc adsnalfed by Polariad Light tvtluoropy @IJvfI F{Eh s1qryrb $t EsJptemg[icrly Edfa{ tho dcmiUbn that a sample in a set comid asbcstoc, Esb6is of 6c rcmshing sunplcs in thc sct was discoutimcd. If m asbcsma *rs dccctcd duing th ulys, fu sspcc* maUial was dctcmined to bc rcgtive for asbestos contcot rArbcils'LcldrlndffilEy3irc AfoTcdiryr*Hcelh eld Sefcty Treinhg* P.'f Boulder Environmental lvlanagcment, Inc. Rcmlt: The following mdcrials urcre amlfrad ad daetmid to bc asbcsoecontaining utilizjng poladzcd [ght microccopy (PIM). compositc porccntage drywall system is one percent rsbestos or Rcgulrtay agmcits comider dr5rrnlt md joir coupouod e fnish rysfro lhat is e compocits of both building mrtcrhb. Thc two s|tbFrts, drJrsrall sDd joint oomipund arc anlji'zd sqan0ely for rcboe. If e rnbport conAinr asbestoc, th@ thc ovErdl .$bcstos ooteot of the comtinoa - $rb-Fr$ b u$d to d€fiormirc fu hrad cbssification of &y*rll and jcint conpound as a sys&E- Tho Ervhoncntal Mion Agacy ud ttrc *c of Colmdo Dc4artnart of hrblic Hcalth rnd Ewironnoat do not rwulttc drywdl ard ioint ccupound thd hevc ra ovcrall asbcdos cotout ofl7r s lcss. Howevcr, OccupafioDrl srfctlr rnd Horfh Adninistntioo rqul*iw epply to*oterr hrndlin8 thc mricrial Tbc following mrtcrials rrcrG amlred md daernincd to bc trace a$cstoecooiaioing utilizing polrizcd ligbt Eicroscopy eLM). TRACE ASEESTO$C{)NTAINING MATERIALS The follcrring maHials wErc aDslrred md daernid to bc nm cbcstos.cmtrining sfi lizing poluizrd li glrt microsopy (PLM). NON 'Arbertorrleedrlnfusbid Ilgirocrsrfcty*Fird Air Tcrting*rllcdtt rndSddyTnhhg: ASMMATEnIALII MATERIAL SAMPLELOCATION SAMPLEII'CONTNNT Drywall joint compound Ivlaster bedroom -north wall l2-6-CR-03A|,3% Chrysotile rThs ovorall of asbestos MATERIAL LOCATION SAMPLE II' Windowglazing Westwindows t2-6-CR-07C r2-6-CR-08C l2-6-CR-09C AININGMATARHI.S MATERIAL LOCATION SA"I}IPLE ID Mastic lo floor bathroorn ld floor bathroom l* floor bathroom l2+cR-048 l2+cR-058 t2-GCR{58 DEC ll 2OOG l1:30f,ll BoULIIER El{vIROniEtlTFL r (AGGI 69S-+121 p.6 Boulder Environmental Managemeirt, Inc. tu* i,BlH'H'd "*Hfiffi ,-n, r, DisculEior: Sanple analyscs tesults are rqnrted in per,ccatrges of destq ad nm-asbestc conponc,nts. The EPA defines rny mderial thd,codains greater than one perccnt (l7o) asbcstog uili-ing PLM, as being m asbe*os containirry mauial. Miterials that are idcotified as bn deac.tcd" arc specifu rs lot contaidtg r$cstos. Cone.lqrion: Thc joint conpornd on th dqmdl jointconpond rylicil ud thcrindcr 3|uirgcontdnr one pcncctrt sbcrtor or lcss. .The deurolition r€qdres OSHA catcCry 2 asbesbs r@oval wuk practices. It is rcconmended ftata li;cdasbcstos abatcocu couFrtabc rctaincd fq t[is demolition to omply with osHA roquircments regrrding the dcmolition of asbestos oonaining materisls that conlain lesr tha l% asbcsbs. The OSHA rcgulation 29 CFR 1926.1l0lfuXlxii) and (;ii), ar urell rs rccord-&ecping rcquirocnfr under 29 CFR 1926.1 lOl(n) thet ue arsocirfed with tbe cgative exposure asscssmenl ryply so long as ncilhr asbcstos pcrmissibh cxposurc limit (PEL) it cr(occded or Eight be exoccdcd- 29 cTR 1926rl0l(gxl)Qi) rcAdrcs: "Vct methods, or nn{ting agents, to contol eorployce Expo$.trel during rbestos hNndlin& mixin& rcmoval, o{ting qdlc*ion, andclcanri, cxc€ptc,tere employerc dcnmstrde th"t tbp usc of wct mctbods is idcasible dw to for exrnplc, fu crcatiqr of elccicd hazrds, cquipm.ot rnlfimio, rn4 in roofing, orccpnasprwfub in parrgrryh GXt)Gi) qf this stiur;" @d 29 CFR 1 926. 1 l0l(gxlxiii) r€qutu€s '?rompt chaarry sDd dispost of vnstcs md dcbris coilininatcd with a*cstos in leak-tighcffiincrs qccpt inrcofingopcr*ior, uhcrc tb gocedus ryodfied inpurgr4h GX8)Gi) of this wdm qrply.' The reulrs of this survey pe*tain orly to nitcrials tcstod- Thc labofioryrcpqts sryputingthc findingc at atlachcd Appficablc stab. fcdcrrl, ndlocal cnviromenlal rqulaims stipulme th* mly a licecd arbcstos rbo!€mcnt coruactor sbuld disMb sbcrtos cortridlg Eeilk *Arbcrtocrlad.hdrrtirl Eytlac.Sdcty*Fild Ah TstbSt*EcftudSftyTrftirg' DEC 11 eOoB I 1:3ORll BOULITER EtlvIROlltlEltTBL : I (AA6! 699-+la1 Boulder Environmental lvlamgcment Inc*[ffi,X'*hf,ff*no, Please mdact Boulder Enviromental Mmgerrcd, hc. with any qncstiurs or crrrccms rcguding thir report Sinccretn Chisli&ron ProjectMaryFr ' rArbgtoc*Lcrdrlndurthl EghcrSefctyrFiul Air Tcting**Ilaf,h rnd SddyTnhing' ?.? DEC l l 2OOG l 1:3OFl'l BOULIIER ElMROt'lt'lEttTRL I (466t 699-{121 Craig Renz S Detr fteiil Roe4 Borldcr CO 80:f{t3 he n+er&lb conpletd thc EPlt Col*do Apowd IIIELA ASBESTOS BUILDING INSPECTOR INITIAL COUR$E For prpoeas of rccridit tton r€Cuu€d rrndar S*otioo 206 of the Toxic Subit*oscs Cqtrol Act (fSCA) And tlrc Colorrdo Dcpnmant of Public lleahh srd Environrwff Rcguhion #t- Conduaed $, MISER$ INSPECTION & TRANTYTNG, INC. lE25 West BakerAve. - Englewood, Colorado tOl l0 (303) v22-8E21 Ofilce (303) e22-0124 Far Course lhe: $eptemher 2S.?7, 2006 Tbis sour$ has becn granGd approvol by: EPA Rcgioni VIII The $tate of: Colorudo ABIT43469-{X (,l*tifbutc N smb€t $eptcmber27'-2W7 Expirur on abovc Dac trtmo N oo td(rt!3 tdoc Erflxt |l|z ttoz3mz Dt- ooo o ao @ II N ! @ DEC 1l 2OOB I 1:34H){ BOULIIER ENVIROII}IEI]TFL ion$.gl0f,oi*F!R$T GOLISCTED*}: RTfiE||tilDSY: r rs66) 6s9-4121 P. ro RESERVOIRS EI{VIRONTENTAL, INC. l'lVLAP AEs!f,ed L*orrbry t lOl8SA TDH Lbnted Labo.rbry, 30i'l:15 TABLE PLTI BULK AI{ALYSIS, PERCEIfTAGE COI'POSITION BY VOLUTE Pqe2ol2 trtm Noc'o IJ{t3 RES Job Number: Cllcnt: Clent Prcjecf Numbcr / P.O.: Client Pmjecl Dero.lplion: Dal,e Sampleo Recslv.d: Analysb Type: Tumaround: D|teAnalfred: RE8 tt3glr-l BouHcr Envlrcnmadrl rrn gcrnent Itlono Glwn Lodgc rt vr[, Unh !i10, Vrll D.c.mbrr 6, 2006 PLI, Shoil Rrpoil 24 Hour Deocmber !, 2O06 Andyrt RSU' t! r mF fiz lino23mz+!r ooo' otto(o Ia N ttW =:--hq ! N A Y E I SubPhysical I PadDescriplion | (%) t2s4R{{A 124€R-0:tA lr{€R{tA la84R{/tB EM 699097 6eeogE 699099 899100 699t0r 699i02 A B c A B AI c A A A A A A \Mrib plaster vhit€rssam plast€r TanArfiite dmrall whlt€/cream plasbl TarJVirib d4nlall lMrilo plrrter Vuhrcrcreem plsEr TanArltritc drywai Gray gr.nular pla3lar Gray grailIar pbst€r Gray gmnular phsbl Cream glara w bEu,n palnt Cream gbze w/ brovrn painl Crcam glaze d brown painl 30 35 35 15 E5 33 33 34 100 100 100 100 100 1m ND - No.. Ddrclod Tl - Trs, < l!6 Vinsl Errinub T|E||},Ad. Trlr\dlc'^de|o|b DEC r I zOoE I 1:3681'l BOULITER El{vIRO?{I.IENTFL I (456) 6S9-+l2l P.lr P.gc I ot2 2059 Brrlnt SL Danvar, CO 8021'l (crs) 90+19S6 Fsx (fu) 1714275 Toll Fr€e (066) RESLETW Ilsnbar8.2ffi Crui!Marcn Eonldcr Eruttmmenid Menagsnent 5 DeerTril Road BorIdsCO8Gm Deer Cusb|rEr, Re6ervd6 Envirmmental, Inc. ls an analytkal lebordry acctcdiEd for the amlysis of lrtsttotid Hydene and Envtronm€ntal metrlces by lhe Nationd Voluntary bborebry Acct€clfiion Ptogram (NV|-AP), Lab codc | 101696 and the Ameft5n In(tl8tial Hygiene As3ociatbn (AIHA). l€b ]D 101533 - Accreditrtion Cen|ficalc tt0tt. Thic laDoEto.y b ciltl€.tty ptdrdefit ln bdt Plddency Tes{ng and PAT prcgrams Espcdlvsly. Ressnoitr Ervilqmcntal. fr. hl ru|;.ld Up ftilorilE srCG for etolb oonbnt a Fr lotr |!qu.d. I|! rnrlllsh hs bsr odacC h g€n rd .@fltnca rilr tt€ dppropdatc mclhodology as drlrd httefrdred erShfifr.Thctlsrb haF b€Gn a.omitHbyouroffE. RESltll981-l lsthejobnumberGsignedtoUisltudy. Thlsr3pdtisconsldor€dhighlyconfidentisl and he sdc prcperty of tre orstomer. Rererudr EnvironnEnhl, lrrc. will nd discil$ ary pen of tlls strdy u,ith p€rsonnelofter han thos6 of the client. Tho r€sults d€scribcd In tfils rEport only apply lo the sampl€s anatyz€d. Thls Eport mud not bc u!.d b claim cndorsemont of produdt or analy,ti.al lgsunB by I{vlAP or any'ryncy oI 111e U.S. C;overnment. Thb report *ratl not be repmduced excepl in lull, wilhout wrlten apilrovat lionr Ree€rvairc Envircnmentsl, lnc, Sampl€s will be disposed ot atler sixty day€ tr|l9ts longcr sia6ge is rsqucted. lf you have any qrnstions about thb t€po4 plcete f€€l tree b call 30996t1-1985. Sincercfy, Jeanne Spenccr Orr Pr6ddent Aoaly*(s): l,.Donbrt cod.r Srtconorct llufib.n bborr[ory Rcpott ftoJ.ct Drcnpuo||: RE3 XA RE8lt3ell-l ffoor Onur t'o|h. rtvrl tlrlt D!0, Yrll Paul D. LoScalzo Paul F. Kn.ppe MifidScdct \ilbnlong Liu REh Ylbgrzytl Bil To \t'alkcr Building Conpo, y Gry Walkcr P.O. Box I l3t Eaglc, CO t 163l Date Invdcc # tu)m6 4531 Sl*p To Walkcr Building Corqmy Gary f,ralker P.O. Box I l3t Eaglc, CO 81631 PO. Number TemB Rep Ship Via F.O.B.Prqed Not 30 tU9./m05 lodgc al vail #530, VEil Quantity Item Coite Descdp0on Pdce Eadr Atmunt I 9 ritc visit S200 Bu&acbcsbs Sitc vicit by I strte cfColorado c,atifiod arbestor hryector, incMcr building daaarrizarion, npqt writing, tavcl to hb hrlt sarplcs andyzcd by polrizad light mlroacopy, EpA Mcftod 6(X)iR-Elll l5 300.00 25.00 300.00 n5.00 Wo now scccpt crsdit crdt Total ts2s.m Floor Live Lood 40 psfFloor Deod Lood i5 osfWind (3 Second Gust) ---- 90 mph (Exp. B) le'smi.c..Design Cotegory --- EXEMPT lieC rOr+.r.r;IBC Edition --- 20Oj : ' STRUCTURAL WOOD FRAMING: o. Except where noted otherwise, oll 2" nominol lumber, except studs, sholl be DouglosFir-Lorch ff2 ond better.b. Studs sholl be Stud grode ond better Douglos Fir-Lorch or Hem Fir.c. Built-up posts sholl consist of Douglos Fir-Lorch or Hem Fir fi2 or better 2x4 or 2x6studs per plon ond sholl be noiled together with 2 rows of 16d noils @ 6" on centerolong eoch stud. f. Built-up beoms consisting of multiple 2x members sholl be noiled togeiher with two rowsof 16d noils spoced ol 12" on center, or with two rows of 1 /2" diometer thru-boltsspoced of 24" on cenrer. Ledgers ottoched to mosonry wolls sholl be treoted Hem Fir #2, or if LVL moteriol isused, sholl hove o continuous woterproof membrone between ihe concrete ond the wood.Lominoted veneer lumber (LVL) sholl hove the following minimum properties:1. Flexurol stress ---- --------- 2600 psi2. Modulus of elosticity - ],9OO,OOO psi3. Tension porollel to groin j E5O osi4. Compression porollel to groin --- 2Jl O osi ? Compression perpendiculor to groin (porollel to glue line) --------- 750 psi6. Horizontol sheor ---- ------'--- 2g5 bsi 7. Connection of multiple-member beoms:A. Side- looded beomsi) For two or three member beoms, noil eoch member to the next with 3 rowsof 16d noits ot 12' o.c.ii) For four member beoms, bolt through with 2 rows of 1/2" diomeler bolts ot12" o.c. Aff f umber used in construction sholl hove o moximum moisture content oI 19%.1. Floor Construct ion: A. Provide 3/4" thick APA roted Sturdifloor roted of 24" o.c., tongue ond groove, exposure 1. Glue ond noil ponels to oll supports with 8d noils spoced ot 6" olongponel edges ond o_t 12" olong intermediote supports. lnstoll sheothing with longdimension perpendiculor to joists ond end joints stoggered. GENERAL REOUIREMENTS: o. Structurol erection ond brocing: The structurol drowings illustrote the completed structurewith oll elements in their finol positions, properly supported ond broced. The controctor,in the proper sequence, sholl provide shoring ond brocing os moy be required duringconstruction to ochieve the finol completed structure. iontoct itructurol engineer iorconsultotion (not in controct) os required.b. Existing structures: Controctor sholi be responsible for verifying dimensions, elevotions,froming, foundotion ond onything else thot moy offect the w'orti shown on the drowings.Underpinning, shoring ond brocing of existing siructures sholl be the responsibility of thecontroctor.c. Dimensions: Check oll dimensions ogoinst orchitecturol drowings prior to construction. Donot scole drowings. d. Construction proctices: Generol controctor is responsible for meons, methods, techniques, sequences ond procidures for construction of this project. Notify structurol engineer of omissions or conflicts between the working drowings ond existing conditions. Coordinote requirements for mech onic ol /eleclricol /plu mbing penetrotions through structurol elements with structurol engineer. Jobsite sofety is the sole responsibility of the controctor. All methods used for construction sholl be in occordonce with the lotest editions of the tBcltRc.e. Detoils not specificolly shown on the drowings sholl be constructed in o monner similor to the detoils thot ore shown for like conditions. These items sholl be brought to the ottention of the structurol engineer os soon os possible for opprovol. Approvol sholl be f. ob toin ed orior to instollotion.It is the responsibility of the controctor to contoct the structurol engineer of the oppropriote time to perform site observotion visits. Observotion visits to the jobsite by the engineer ore for determinotion of generol conformonce with the construction documents ond sholl not be construed os inspection. Though every effort is mode to provide o complete ond cleor set of construction documents, discreponcies or omissions moy occur. Releose of these drowings onticipotes cooperotion ond continued communicotion between the controctor, orchitect ond engineer to provide the best possible structure. These drowings hove been prepored for the use of o quolified controctor experienced in the construction techniques ond systems depicted. Town of Vail oFpnr* qflPY 9. d. 9- E @I(\|I Nool\l tt)(\I v, N x !{ cn =EFvr t\lv, FIoot\o ctrcEo =ltlofflIttr* (g (uE! J Ctrrct ot\ov)IL =19 =o - odl JAN 2 5 2007 JL 4x4x1/4 w/ (3)-1/4"6x2 1/4 SIMPSON TITEN SCREWS IN EA. ANGLE EDGE OF NEW OPENING CMU HEADER FOR NEW DOORS (3'-O MAX WIDTH) t3I :$::dii 3;EAi, ;! E ! 8E::iJt!. oaE -A-v-Ho,-rFO.'-. ;'l 6l( !' t<bv>H; .O(J(U:j F'dOH>I aotr1 I o\ &cacd byJE-- cor,r ry ---4!-d.ttd bt - isad PER'r'tl 01/23/01 *'=,- JoB 10701-03 PLAN NORTHSEONDooRfRAMING PLAN PLAN NOTES: 1 l99ls-B^+o_w_(_oRlG!NArtNG FROM THrs LEVEL oR ABovE) ARE TNDTGATED: tSINGLE STUD TRIMMERS THAT DO NOT REQUIRE ELOCXINd EELOW INE rI,rbrCFrCO. I2. ALL COLUMNS ARE LABELLED AT THE TOP. 3 (ryL.IlO9B SH-EATHING IS 3/4'' TONGUE AND GROOVE APA STURDIFLOOR, EXP.I, SPANRATING 24 O.C. 4. WOOD BEAMS AT THIS LEVEL,EXCEPT HEADERS, ARE FLUSH WTH FLOOR JOISTSuNLEss NorED (DRoppED). S. "O" INDICATES coNNEcTIoN TYPE _ REF. SI FoR SCHEDULE. 6. ALL (N) FLOOR JOISTS ARE 2xE's @ 16" O.C. (E) REFERS (N) REFERS TO EXISTING CoNSTRUCT|ON (* - - - - - ),TO NEw ( NOTE: (N) HEADERS FOR INTERNAL AND EXTERNAL NON LOAD BEARING WALLS SHALL BE (2)-2x10's w/ (t)-2x+ TRTMMER AND (1)-2xa KING STUD @ EA. END. SCALE: 1 2xE LEDGER, FASTEN T0 cMU WALL W/ 1/4"o x 21/4" IfiEN MASONRY SCREWS, TYP. 1/s1 JAN 2 5 ?007 NEW CMU OPENING IN WALL, SEE 8" CMU WALL (vERtFY) = Itt Ft F{ l\ooa\l Itta\ ({vl T\x d3E'FU' (\v, (a1oot\o E'r.Exo tnoFIto+ IE ru(uolEoJ Oro oottt|cL =I =o tf--r;--:\--n11 ti '\\ pl 'rl -L'- - -!: l-] [: tl_---.r-| tl--tt t: N l- IGl rN EEE I I ltN ), i I 'ENI )v.E)VE I -j=-r- ,tiNEWiOP WALL (ABOi'litil ::lT --\- ;\qMU + 1,/s1 ,ti :iT I Ih-l'l mllr - lg- tltl riF ll'itrrL'-li-ir -f I_r I-T- alFl ol]_al-lr IJ- II s lr,-"'....'1..{ ir'/7,q1 i\!l J) + r\x* r.) c\o i---L----.':---r-- !--CONNECTION SCHEDULE @ SIMPSON LUS28 @ STMPSON HcU57.25l8 o SIMPSON LUS46 o SIMPSON HU48 w/ (8) l/+xt 3/+TITEN MASONRY SCREWS ii*Sidlt r;ggg 5g?i !iii Ocrq.rL() -:thxHo '-rF!.- ;'! 6n(v irA>trr:-.t3 Ei,; rE* QOEI qx drdgrd b;JEl- corr ty -.J9!-.n .bd bt - bt ait ??evtl d f23lo7 S2 Joa ro70r -o3 TowN o. voir FIRE DEPARTMENT 75 S. FRONTAGEROAD VAIL, CO 81657 970479-2135 VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ALARM PERMIT Job Address: 174 GORE CREEK DR VAIL Location.....: THE LODGE APT CONDOS #530 Parcel No...: 2lOlQ822lO74 Project No, -7RTO 1 - OOOCT. Permit #: Status . . Applied . Issued. Expires . AO7-Cr,32 3O1- od t5 . : ISSLIED.: 0412712W7.: 05lIU2m7.: ll/O7l2W7 OWNER TYTEL, HOWARD & SANDRA lOO OYSTER BAY RD MII.,LIiIECK NY 1_L7 65 AppLreANT STMPLEX TrME RECORDER COMPAIIo4/27/2007 Phone: (303) 355-0500 6240 SMITH ROAD DEI{VER coI_,oRADO 80216 Lricense:105-S CONTRACTOR SIMPIJEX TIME RECORDER COMPANO4/27/2007 PhONE: (303) 355-O5OO 6240 SMITH ROAD DEN\TER coLoRADO 80216L,icense: L05 -S Desciption: ALARM REMODEL OF UNIT 530 Valuation: 32.800.00 FEE SUMMARY *rt*tr*t'r*'l'l***+l.**'***r.':'r******'r'r***'***x.'r*i.*t(*:r*'.**)i***rtr.'t**** 04/27 /2007 Elecrrical----- > DRB Fee---- '> Investigation--- > Will Call----- > TOTAL FEES-- > $0.00 s0 .00 s0 .00 $0.00 9337.00 $337.00 s0. 00 s337 - oo s33?.00 to. oo Total Calculated Fees- > Additional Fees------ > Total Permit Fee---- > Paynrents----*----- > BALANCE DUE-----.-. > Approvals: Item: 05600 FIRE DEPARTMEIflT O5/O3/20o7 DRhoades Action: APPR Approved as noted:L. one set of stamped, approved plans must remain on-site.2. I-,ocation of smoke detectors on second level, in relation to slope of ceiling, may need tobe changed. tunount of slope not noted on plans. CONDITIONS OF APPROVAL |*'|:l**+***'|'}******'|***:}*:|****'t*|,l**ti*|.*t++**l.{.**{.{.*l.{.l.|+|t+**ti|l+****|i.**:|***t****:|***+***|.++****** DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto. AM-5PM.REQUESTS FOR INSPECTION SHALL Bf, MADE TWENTY.FOUR HOURS IN CTOR FOR HIMSELF AND OWNET APPUCATION VYILL NOT BE ACCEPTED IF I]{COMPLETE OR Project #:k*e3a Building Alarm Permlt #: 75 S. Frontage Rd. Vail, Colorado 81657 COMPLETE VALUATIONS FOR AIARM PERMIT (tabor & Materiats) FireAlarm:$ Jtf.,f; Fire Ala rm C.ontractor: ),,rlo lt r /r ^....,.r,rii, Fax#: ].., i. ?Sl -L)L,, t: Asrewrc Offrce at 970-329-9640 or visit for Parcel # Job Name: , c,cl1e G"l- y'.-ri I vn, f SJ c) Job Address:ll'l Ltc..r CreeV-D. Legal Description ll Lot: ll Btock ll rning:Subdivision: Owners Name:Address: vAf|. F|pc UEDAQrAaENT Engineer:Addressr H'rgl!3*tr Detailed Location of work: (i.e., floor\tii i t.- loova ro,-; t \ Detailed description of worlC fe,n;J(, t r.q U,r,' f 53 C W. flqt r'a, Armn WorkClass: New() Addition( ) RemodelM Repair( ) Retro-fit( ) Other( ) Typeof Bldg.: Single-family( ) Two-family( ) Multi-family( ) Commercial( ) Restaurant( ) Otherf{ No. of Fxisting Dwelling Units in this building:No. of Accommodation units in this building: Does a Fire Alarm Exist: Ves (.() No (Does a Fire Sprinkler System Exist: Yes K) No ( ) ***************************************FOR OFFICE USE ONLY************************************* t t. Y rarir r Lr-tr. -: -L,' liPublac:WaViPennitFiiie:,*,:]i,ri*F*r1 A*oa"OBv!.+;;,-+:.,^,1ffif.','- t li rl 2 J PR zo 2007 lU, I' &(; ie il tV t- fr,r1 ll ii;IAPR 26 2007 ll /ilullt 2-- aJ F:\cdev\FORJT|S\PERl4m\Fire\alarmJerm-12{5-05.doc pagelofs i IOW IL tqca SIMPLEXGRINNELL 5240 snith Rd, Denver, CoLorado 802L6 www. s i.mtr>l-exgrinnel-7 . com TeTe: 303-355-0500 Fax: 303-355-0675 Fire & Security SimpIexGrinneII Lodge at Vail Unit 530 174 Gore Greek Drive Vail, Colorado 81657 VAIL nAE DCpAnT,f{tNr htn uh r llrtfbl o TYPE: $implex@rinneII 6240 Smith Rd Denver, CO 80401 Sales: (303) 355-0500 Service: (303) 355-0500 Fax: (303) 355-0615 DESCRIPTIONT 4098-9714 Photo Sensor 4098-9733 Thermal Sensor 4098-9794 Sensor Base with Sounder 4905.9942 Sklrt for existing speakers S,Simplex UL, ULC Listed;FM, CSFM, and MEA (NYC) Approved- TrueAlarm@ Analog Sensing Sounder Base 4098-97941or use with TrueAlarm Photoelectric, lonization, and Heat Sensors E@ Modular TrueAlarm sensor base with built-in electronlc alarm sounder: r Piezoelectric sounder provides high output (88 dBA) with low cunent requirements (20 mA)o For use with interchangeable TrueAlarm sensors; photoelectric, heat, or ionization (ordered separately) Sounder operation can be: V . Po*"rrd from 24 VDC or lrom a compatible' Notification Appliance Circuit [NAC). Synchronized via communications** or by the NAC, if NAC powered . Manually activated from the control panel TrueAlarm analog sensing operation: o Analog sensor information is digitallJ communicated to the conhol panel via MAPNET II. or IDNetrM, two-wire conununications- . Sensor information is processed by the control panel to determine sensor status For use with Slmplex@ control panels model 4010, 4020, 410!, 4100U, 4120, and Universal Transoonders \.\ Functional and architecturally styled enclosure for ceiling or wall mountlng: r Sound louvers exit both fiont and side for high output sound e Smoke sensor louver design directs air flow to chamber, enhancing smoke capture o Built-in magnetic test featurc Optional accessories: r Remote alarm LED indicator on single gang plate o Alarm LED tracking relay UL listing status: r Sensor and sounder operation is listed to UL Standard 268 . Sounder operation is also listed to UL Standard 464 as an audible notification appliance 'R6turlopage4furULClblingstatus.nispDducthasbeenapprwedby0ECalbniaSfrFiE Marshal (CSFM) Frsuant lo Seclion '13114.1 ol he Califomia Healh and Sahty Cod€. Se€ CSFM Li;li4$ R00{0m:217 and 7?l{)026:El ltr alo'vable vdues 8rrd/o. co.dbnr ccpeflirg maledal pGenled i!4 ftb doqmsnt lt b sutiecl b rF€xanimtbn, D!ki4 ard pocsfih cancalalbn. Accepl6d br use - CiV o{ Nfl Yod( Depatnent ot Buidils - ME Bt93E. Addilbnal llstrlgE may b€ apphabh, conlrl ]o!.1@l Sirder podrrt $lppf,€r b ho hbsl sbtu. Lisliqgs and apgwab under Sinplex Ttre Reoder Co. a.s he Flpody 0l TIto Saht Prcducb Wssbnhsler. " Total quantity ot soonder bas€s a\slaue br aiding on he sam€ communaalims channd may \4ry wih parBl appliulion and a,aiablily ol NAC po{er Refer to specilic conh }rnel reqiremenE. t TrueAlam anahg seascrs atr Foted€d by ono or mfe of t|€ bloNLro U.S. Pabnb: 5,155,4{i8; 5,1n,663; 5,400014; 5,543,77: 5,710,541; 0983,407; D388,352: m92,573. IIAPNET ll a{ lDllet addEssable c{rnmunic"lim designs a|9 gotedod by U.S. Pabflt tlo, 1J96,021 TrueAlarm Pholoeleclric Sensor Mounted in Sounder Base 4098-9794 Sounder bases combine an audible notification appliance and a TrueAlarm analog sensor to provide: Digital Communlcation of Analog Senslng. Sensors provide an analog measurement that is digitally communicated to the confol panel where it is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value. Intelllgent Data Evaluatlon. Monitoring each sensor's average value provides a software filtering averaging process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability offalse or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is slored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is deterrnined at the control panel, selectable as more or less sensitive as the individual application requires. Timed/Multl.Stage Selection. Alann set points can be prograrnmed for timed automatic sensitivity selection (such as more s€nsitive at night, less sensitive during day). Control panel progamming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5%o Ievel may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel detennines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. s4098-0028-3 9/2003 ffi Base mounted address selection allows the address to remain with its programmed location when the sensor is removed for service or type chenge. Access is from the front under the removable sensor. Automatic sensor type identification provides default sensitivity when substituting sensor types. Different sensor types can be easily interchanged to meet specific localion requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. lntegral red LED indicates power-on by pulsing, or alarm or trouble when steady on. The exact status is annunciated at the fire alarm control panel. Flre alarm control panel operatlon features include: o Individual sensitivity selection for each sensor o Sensitivity monitoring that satisfies NFPA 72@ sensitivity testing requirements o Peak value logging allowing accurate analysis for sensitiviqr selection r Automatic, once per minute individual sensor calibration check verifies sensor integrity . Automatic environmentalcompensation . Display ofsensitivity directly in percent per foot . Multi-stage alarm operation o Ability to display and print detailed sensor information in plain English language Et'ElE6f,!il 4098-9822, LED Annunciation Relay activates when base LED is on steady, indicating a local alarm or trouble. Contacts are DPDT, nted2 A@3DYDC; l/2 A@ 120 VAC for transient suppressed loads (requires external 24 VDC coil power). 2098-9808, Remote red LED Alarm Indicator mounts on a single gang box to provide status indications where the sensor location mav not be readilv visible. tilttilrF,fiEEllJ*l Electrlcal Box Requlrem.nls: (boxes are by others) Wlthoutlglay: 4' octagonal or 4" square, 1-112" deep: single gang, 2' deeD lIilhlglal : 4' octagonal or 4' square, 1-'l12' deep, wit\ l1n" extension ring 4" (102 mm) Octagonal Box Flush mounl reterance, mount even wilh linal surface, or wilh up to 1,/4" (6.4 mm) maximum recess Ootlonal 4098-9822 Rolav (Mounts in base electrical box and requires additional volums, see notes below) Nolo: Single gang adapter plals (RACO No. 787 or equal) is IgquilelLM€n using 4' square box (by others) 4098-9832 Adapter Plale, reouir€d for mounting to g[fa@ mounted box€s (mounts inveied) L-szi6. (164 mm)-----J-r- 1-1t8' (29 mml-.s (Photoelectric s€nsor shown for reference) NOTES: 1. R€visw actualwire size, wire counl, box type, and whether 4098-9822 relay is used before determining box size. 2. Mounting to flush mounted box also lits single gang handy box, 2-118' (51 mm) doep if wiring allows. (Not applicable if 4098-9822 r€lay is us€d.) 3. For surfac€ mount€d boxss, use 4'squar€ box wilh single gang adapler plate (RACO No. 787 or equal, by others) or 4' octagonal box, both require 409&9832 Adapter Plale. 4. Whsn 409&9822 relay is us€d, mount relay in elecldcal box and use 1-ll2'extension ring (by othsrs) on 4' squar€ or octagonal box of'l-112'or 2-118'depth as required. 5. R€ter to Installatlon lnstructions 574-707 for additional infomation.gSlr'rpb o 2098-9808 Remote LED Alarm lndicator s4098-0028-3 9/2003 Sealed against rear air flow entry Electronics are EMI/RFI shielded Heat sensors: o Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation . Spacing distance between heat sensors: Smoke sensors: o Photoelectric or ionization technology sensing o 360o smoke entry for optimum response r Built-in insect screens TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly mea.siures the local temperatue for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15' F (8.3' C) or 20" F (l |.1' C) per minute. Fixed temperature scnsing is independent of rate-of-rise sensing and programmable to operate at 135" F (57.2" C) or l55o F (68" C). ln a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the tempcrature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature exhemes in the range from 32" F to 155' F (0' C to 68'C). This feature can provide freeze wamings or alert to HVAC syslem problems. (Refer to specific panels for availability.) 6.7/16.664 mm)----J WARNING: ln most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would Initiate an alarm. In cases where Llfe Safety is a factor, the use of smoke detection is highly recommended, ffi TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provid€ consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7o/o per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 360' smoke entry for optimum smoke r€sponse. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 6-Z1 6' (1 64 mm)---=--+l 4098-9714 Photoelectric Sensor with Sounder Base ffi TrueAlarm ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in envhonmsntal conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence ofparticles ofcombustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels ofsensitivity are available for each sensor: 0.5, 0.9, and 1.3% per foot ofsmoke obscuration. 6'7116- (164 mm)-- -l 4098-9717 lonization Sensor with Sounder Base EtttEftffiElllfit Sensor locations should be determined after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72,the National Fire Alarm Code@. On smooth ceilings, smoke sensor spacing of30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual, Part Number 574-709. 135' F (5i.2'C) 15 fi x 15 ff (4.6 m) fixed temperalure only; 30nx30fr(9.2m)fxed60 fl (18.3 m) 4098-9733 Heat Sensor with 4098-9794 Sounder Base s4098-002&3 9/2003 TrueAlarm Sounder Base' Optlons: 2098-9808 remote LED alarm Model 4098-9794 (C) Model 4098-9733 (C) 4098-9717 (C) Sounder Base Description Sounder Base with connections for Remote LED Alarm lndicator or Unsupervised Relay 14 (c)Photoelectric Smoke Sensor Accessories (ordered separately if required) Description Adapter Plate, requir6d for surface mounted 4" electrical boxes Compatibility Sensors: 4098-9714. -9717. or -9733 Description Mounting Requlrsmsnts Refer to page 2, mounting reference Mounting Requirements Refer to page 2, mounting reference Mounting Requlrements Refer to page 2, mounting reference Model 4098-9832 2098.9808 Single gang box, 1-1/2" minimum depth 4098-9822 (C)Mounts in base electrical box (requires 1-1l2' sxtension on 4'square or octagonal box) ' Rafer lo data sheet S4098-0019 for other compatible bases. Refer to Installation Instructions 574-707 and Application Manual 57/t709 for additional information. ULC listed model numbers are designated by (C)and require a 'C'suffix such as 4098-9794C. El!?rm+rftiE General Operating Specifications Communicalions and Sensor Supervisory Power MAPNET ll or lDNei, auto-select, 24-40 VDC ddata,400 tA typical, 1 address psr base, supplied by conirol panel Communicalions and Sounder Power Connections Screw terminals for in/out 18 lo 14 AWG Remote LED Alarm lndicator Cunenl 1 mA typical supplied trom communications, no impacl to alarm current LED Connections Color coded wire leads, 18 AWG uL Listed T 32' F to 100' F (0' C to 38' C) Operating Temperature Range With 4098-9717 or 4098-9733 32" F to 122" F (0" C to 50" C wirh 4098-9714 15" F to 122" F (-9' C lo 50' C) Humidity Range 10 to 957o RH Smoke Sensor Ambient Ratings 4098-9714. Photoelectric Sensor Air is 0-2000 ff/min m/min) 4098-9717. lonization Sensor Air vslocity is 0-400 fr/min (0-122 m/min); Altilude is up to 8000 fr (2.4 km Housing Color Sounder Operatlon Sounder Voltage Alarm Cuffent (Sounder On) Sounder Output Sounder Power Supervision (Selectable) NAC Powered Ooeration 4098-9E22 Unsupervised Relay Option Externally Supplied Relay Voltage Frost White 18 to 32 VDC from steady external source or from NAC 20 mA @ 24 VDC, 24 mA maximum @ 32 VDC 88 dBA minimum @ 10 fr (3 m) per UL Standard 464, Aud,Dle Signaling Applianc$ and UL Standard 268, Smoke Detectors for Fire Ptotective Signa/ing Systefis Supervised Seloct for continuous 24 VDC power, loss of power is communicated to panel Unsupervised Selecl whon connected lo NAC for sounder power, NAC provides supervision When in alarm, willsound when NAC is in alarm, allowing synchronized pattern (Tsmporal or March Time, etc.) controlled by the NAC 18-32 VDC, steady source recommended (wires to remote LED l€ads) Alarm Current 13 mA from 24 VDC supply Contact Ralings, DPDT contacts for resistive/suppressed loads Power limited rating: 2 A @ 30 VDC Non-power limited rating: 1/2 A @ 120 VAC Operation Tracks base LED status, relay is on with trouble or alarm at the base Tyo, Sinpl$, the Simpler logo, TrueAlarm, MAPNET ll, ond lDNet are trodenark of TNo Inrernational Senites tG or its alliliate: in rhe U.S. and/or other countries. NFPA 72 and Norionul Fire Alarm Code arc rcgistered trodemur*s ofthe Notional Fire Protection Associolion (NFPA). Tyco Safety Ptoduds tryasfm,nsfar . WestminsteL MA. 01441-0001 . USA www.ty co s af e ty p r od u c t s- u s a-w m. c o m s4098-0028-3 9/2003S,Simplex TrueAlarm Sensors (ordered separately) Remote red LED Alarm Indicator on single gang stainless steel olate Relay, tracks base LED slalus (unsupervised, to be mounled only in base electrical box) @ 2m3 TW Salety Pto<ttctt Wesminster All righlt reserwl. All speciftotiors .otd ohet inlongtion thown wr .7tfa1t $ of&rlhenl S,Simplen UL, ULC Listed; FM, CSFM and MEA (NYC) Approved* Multi-Application Peripherals Audible Notifi cation Appliances Speakers, 25 or 70.7 VRMS, Wall or Ceiling Mount Eiltlllfll Fire alarm speakers with models for ceiling or wall mount: r UL listed to Standard 1480 o Four inch cone ( I 02 mm) provides high quality tone and voice reproduction o Multi-tapped design provides output power of l/4, l/2, l, or 2 W with either 25 or 70.7 VRMS input r In/out wiring terminals for 18 AWG to t 2 AWC . Mounts to 4" squar€ outlet box, l-l/2" deep with l-ll2" deep box extension r Capacitor input for connection to supervised notification appliance circuits . Rugged, high impact, flame retardant thermoplastic housings Rectangular housing models feature: . Appearance that complements TrueAlerto strobes and speaker/strobes o Red or white housings with "FIRE' lettering for surface or semi-flush wall mount . Optional matching adapter skirts for covering surface mounted electrical boxes . Optional red wire guard Round housing models feature: . Off-white color (no lettering) for flush mount on ceiling or wall Simplex@ 4902 Series speakers provide high quality sound for emergency fire alarm use as well as for background music. The moisture-repellent speaker is designed for smooth frequency response with minimal distortion. The multi-tapped speaker transformer accommodates either 25 or 70.7 VRMS and provides an output of from 1/4 to 2 W to provide flexibility for satisfring the requirements of the installed conditions. Rectangular housing models are for surface or semi-flush wall mount applications. Round housing models are typically for ceiling applications but can be wall mounted ifdesired. The rectangular housing speakers are designed to compliment the TrueAlert family of strobes and speaker/strobes, providing conventional, non-addressable speaker operation. ' Reler to page 2 fo{ guard listhg. Tlis poduct has been app@ved by fi€ Califonh Slale Fire Ma6hal {CSFM) purslanl lo Sectioo 13114.1 ol ho Calihmia Hodh and Safely Codo. Ss€ CSFM Usling 732Hm26:242 lor altow?ble values and/or conditims conc€ming maleaial presenled In his docunenl. lt is subiect lo re€xaminalion, rovision, and poslible canc€llation. Addibnal lislings may b6 appkable; co0lacl your localSinpl€x produci slpplbr fo. he labsl sl8tus. [islius and applovsls unds Simpler nrc Recordor Co. are the prop€rly ot lyro Salety Prcduds Weshinsl€r. Rectangular Wall Mount Speakers are Available as Red with White "Fire" Lettering and White with Red 'Fire' Lettering Round Speakers are Available in Off-White (no lettering) E@@6 Housing Dimensions Depth into Box Dlmensions, Round Housings Housing Dimensions 2-314' (70 mm) 7-112' Diameter, 1/2" 0 Depth into Box General Specificatlons . Compatible with optional tile bridge 2905-9946 @ffid ffiVI Dimensions, Reclangular Wall Mount Housings 5-1/8'Hx5"Wx1-1/2'D (130 mm x 127 mm x 38 mm) (191 mm x 13 mm) 2-314" (70 mm) 25 or 70.7 VRMS .82 mm2 to 3.31 mmz 125lo 12kHz 32' to 100' F (0' to 38" 10% lo 95% RH from 32' to 122' F (0' to 50" s4902-0003-5 8/2005 tit?JmEEGtt*rf,lltl 4902-9717(CA) 4902-9721 (CA) ' ULC listed model are designated with a CA suffix. Mounting Adapters Descrlplion Red speaker cover wlth white 'FlRE" lettering 4905-9989 4905-9999 Speakers Model' 4902-9716(CA) Model 4905-9988 Doscription Rectangular housing, wall mounl speaKer Red wilh white "FlRE" lettsring Interchangeable with TrueAlert horns Dimensions 5-118"Hx5"Wx1-1/2'D (130 mm x 127 mm x 38 mm) 7 -1 12' Diameter x I 12" D (191 mm x 13 mm) Dlmensions 5-1/8"Hx5'Wx1-1/2'D (130 mm x 127 mm x 38 mm) 6-1/16' H x 6-1/16" Wx 3-1/8' D ( l54 mm x 154 mm x 79 mm) White ,niih red "FIRE" lettering Model 4905-9941 Red Description I Use to cover surface mounted| 1-112' deep box wilh l-1l2"Surface mount adaDtar skirl II deep extension external to I wall (see diagram on page 3) Dimenslong 5-3/8' H x 5-114" W x 3-3/16' D (136 mm x 133 mm x 81 mm) Total surface deoth with speaker = 4-518" (117 mm)4905-9942 White 2905-9946 Tila bridge for 4902-9721 Speaker See diagram on page 3 4905-9931 Adapter Plate, red, for mounting to 2975-9145 box (typically for retroflt, may be mounted vertical or horizontal) 8-5/ 16' x 5-3i4" x 0.060' Thick (211 mm x 146 mm x 1.5 mm) 297 5-9145 Red mounting box, requires Adapter Plate 4905-9931 7-718' x *118" x 2-314' D (200 mm x 130 mm x 70 mm) Covers and Guard Whits speaker cover with red "FIRE' lettering Red wire guard with mounting plate; compatible wilh semi-flush or surface mounted boxes: for use with 4" square elecuical box mounting hole patterns only (UL listed by Space Age Electronics Inc.) Mounting requires a 4" (102 mm) square box, 'll/2" (38 mm) deep, with a 4" box extension, 1-112" deep, by others Speaker assembly Wiring input terminals and sp€aker lap selection are accessible ftom rear of speaker housing Transparent speaker houslng Romovable cover (tool required) , t t rJ , t s4902-0003-5 8/2005 4" square, 1-112' deep box with 'l-'1/2" €xtension (by others) Wiring input terminals and speaker taD selection are accessible rear of speaker housing ffi 1t2' (13 mm) 2311/16'(602 fln) 4" (102 mm) square box, 1-1/2" (38 mm) deep with conduit shown for reference 4' (102 mm) square box extension, l-1i2' (38 mm) deep ODtional 4905-9999 Wire Guard Surface mount adapl€r skirt, 3-3/16" deep: 4905-9941, Red: 490s9942, whito 3-3i/4' (95 mm) squaro 0.024' thick sheet metal, iolded with 1/2 llp each sid€cutout. cent€red on plat6\ | /-a--'.1 \*"or"..r",rod L--rl 611/'t6' ('170 mm) s4902400$5 8/2005 , Sound Output Ratings @ 10 ft (3 m) per UL 1480 Reverberant Chamber Testlng Model 4902-9716 4902-9717 Type Rectangular Housing Input Voltage 25 VRMS Selected T 1l4W 80 dBA 1t2W 83 dBA 1W 85 dBA 2W 88 dBA 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA 4go2-9721 Round Housing either 25 or 70.7 VRMS 79 dBA 82 dBA 85 dBA 88 dBA Sound Output Ratings @ l0 ft (3 m) pe. ULC 5-541 Testlng and per Anechoic Chamber Testing Model 4902-97 16 , 4902-97 't7 , & 4902-9721 i with either 25 VRMS or 70.7 VRMS Test Output Tesl per ULC 5-541 Sslected T 1t4W 78 dBA 1t2W 8I dBA 1W 84 dBA 2W 87 dBA Anechoic Chamber, 1 kHz input, on-axis'87 dBA 90 dBA 93 dBA 96 dBA . Anechoic speaker output ratings are typically more representative of actual installed sound oulput. 85 ;84 o 882 'o 81 o-- oJo79 a-- oLtt 5,.o -2kHz - 4kJlz s0 80 70 60 50 40 30 20 10 01020 30 40 50 60 70 80 90 Angular Displacement (Degroes) on Horizontal Axls 4905-9931 Adapter Plate 4905-9999 Optional Wire Guard (shown hero for reference only, can be used on other mounting options) Speaker assembly Tyro, Sinple\, lhe Sinplet lo8o, ond Truellerl, are lro.leno s ofTlL'o lnternalio al Senices AG or its onilialer in the U.S. and/or olher co ntries. FIRE 490S9931 Adaoter Plate S.Simplex Tyco Satety Producls Westminster Westminster, MA. 01441-0001 . USA ww w. ty co s af e ty p rod u ct s- u sa -w m. co m s4902-0003-5 8/2005 @ 2005 Tlro Wty hofcts Wpttmins@. All rEhts tsoa'ed. All slreilitdio$ od oher inlon nrion show tEre dnott .\t ofd61lnent revision .lote TowN op verl 75 S. FRONTAGEROAD VAIL, CO 81657 970479-2138 Job Address: l,ocation.....: Parcel No...: Project No : ELECTRICAL PERMIT 174 GORE CREEK DR VAIL THE LODGE APT CONDOS #530 2t010822t074 ??lo1 - 6ooQ s57. s0 $0. 00 $0.00 Permit #: Status. . Applied. Issued . Expires . 03 /20/2007 03/20/2007 Phoner 376-L846 03/20/2007 Phone: 376-L846 Total Calcularcd Fees- > Additional Fees----- > Total Pernit Fee---- > w7-m28 Go1 -Oo(.S- : ISSUED: O3l20l2OO7: 04lO2l2N7.: 09/2912007 DEPARTMENT OF COMMUNITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES OI'INER TYTEI,, HOWARD & SANDRJA 1OO OYSTER BAY RD MILI,NECKlw LL75s APPI,ICAIiN PTARMIGA}T ELECTRIC INE. License:373-E CONTRACTOR PTARMIGAI.I ELECTRIC INC. I-,icense: 373-E Desciption: AADDINGNEW LIGHTING AND ELECTRICAL FOR NEW MASTERBATHValuation: $0.00 Square feet: llm 'tt'l,i**{.,t:llrt:lrt:|.*t:t Electrical-*--- > DRB Fee*---- > Investigation-- > 03/26/2oo7 SHAHN Item: 05500 I'IRE DEPARTMENT $60.50 s0.00 $50. s0 Will Call-----> $3.00 Payments----------- > $60.50 TOTAI FEES- > $50.50 BALANCE DI'E------ > S0. o0 Approvals:rtem: 05000 ELECTRICAIJ DEPARTMEMfAction: AP CONDITIONS OF APPROVAL Cond: 12(BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAI{CE. Cond: CON0008799 MAINTAIN FIRE RATING OF 1 HOI'R Cond: CON0008800 REPI'ACE EXPOSED TYPE NM CABLE Cond: CON0008801 ARC FAI[-,T PROTECTION REQUIRED FOR BEDROOMS IF WAIJI-,S ARE OPENED DITRING PRO.]ECT. DECLARATIONS I hereby acknowledge ttrat I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and suMivision codes, design review approved, International Building and Residential Codes and other ordinances ofthe Town applicable thereto. REQTJESTS FOR INSPECTION SHALL BE MADE TWENTY-FOI,JR HOTJRS IN OFFICE FROM 8:00 AM - 4 FIJOOR/CEIIJING ASSEMBLIES . WITH APPROVED CABLE/COI{DUIT. PM. VANCE BY TELEPHONE AT 479.2149 OR AT AND OWNEtr APPLICATIOI{ WILI IIOT BE AGCEPTED IF I1{CO}IPI-ETE OR UIISI Prcjtxt #:- ooo 75 S. X'rontage Rd. Vail, Gololado 81657 6s]. oe)Zg Building Perm Electrical Permit #: 97 O-47 9-2149 (Inspections) TOWN OF VAII ELECTRICAL PER}IIT APPUCATION COT{TRACTOR IIIFORIIATIOI{ Electrica I C.ontractor: ?not?rAt/n o,\ F, F.r'r? |c Town of Vail Reg. No.:373- e Contact Person and Phone #3:Kvzr 3?a - tBya E-ilail Addr€ss: ,3 Fax#: Crntractor Signafure:(n A-- COMPTETE SQ. Fd)TAGE FOR AREA OF WORK Al{D VAIUATIOI{ OF WORK (rabor & lrlatedals) AMOUNT OF SQ FT IN STRUCTURE:ELECTRICALVALUATION: $ /O DOO Offieetg #Par ,# Z, Ot O,C3Z? t O? 4 JobName: Lorrte ,+, l/er- H sg JobAddress: r?/ cxrzn Cunu, pz tegal lt€cription I LoE I Blodr: I riting:Snbdlvlsion: owners Name: 7" Teq I Address: tfr| 3!::1P^y,lt:.- | Pt'one: Englneer:Address:Phone: Debifed description of work: COurro f?eno ec,-_ . F'i".-t^ "rc,-l , .,rs-, etL B,a.rr{ . A o r> ,n,rt N e,--t z- r G Fr i r;) L-> WorkOass: New() {!g!ju"(l rqrd"l(2Q Repair( ) Temppower( ) Other( ) Work Type: Interior ()0 Exterior ( ) Bo$ ( )Does an EHU exist at this location: Yes ( ) No ( ) Typeof BHg.: single-famiv( ) Drpbx( ) MuftFfamity0o oornrnercftil ( ) Restaurant( ) odrer( ) No. of Existing Dwelling Units ln this building:No. of Accommodation Unhs in this buildtng: Is this permit for a hot tub: Yes ( ) No ( )0 Does a Fire Alarm Exist: Yes (V No ( )Does a Fire Sprinkler g6tem Exisil Yes ( X No ( ) ********!r********FOR OFFICE USE ONt eceeIv/E* ********* * ******** F:\cd6AFORIlrS\Fermits\Eif&U\ffiJermtt-1r-232$5.DOC / r-, **rn,9u tu23,nm6 TOWN OF VAIL FIRE DEPARTMENT 75 S. FRONTAGEROAD VAIL, CO 81657 97M79-2135 VAIL FIRE DEPARTMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SPRINKLER PERMIT Job Address: 174 CORE CREEK DR VAIL Location.....: THE LODGE APT CONDOS #530 Parcel No...: 210108221074 ProjectNo : -?T(f 01-600Q OT{NER TYTEI.,, HOWARD & SANDRJA 1OO OYSTER BAY RD MIIJI,IiIECK NY T1765 APPI-,rCANI ALL STATE FrRE PROTECTTON, LO4/25/2007 Phone: 303-288-3901 504s E 76TH #L2 COMMERCE CITYco 80022 L,icense:370-S coMtRAcToR Ar,r-, STATE FIRE PROTECTTON, r04/25/2007 Phone: 303-288-3901 604s E 76TH #L2 COMMERCE CITYco aoo22 L,icense: 370-S Desciption: ADD/RELOCATE SPRINKLER HEADS Valuation: $1.000.00 FEE SUMMARY F07-0023 ISSUED 04/25t2007 05/ut2007 04/2s/20o7 Mcchanical--> Plan Check--- > lnvesigation-> Will Call---> $o - oo Resruarant Plan Review-> $350 - 00 DRB Fee----- $o . oo TOTAL FELS--> s0-00 so. oo Total Calculated Fees--> $0.00 Additional Fees---.----- > $392.50 Total Permit Fe!-----> Payments------.------- > BALANCE DUE-:__-> $392.50 50. 0o $392.50 s392. s0 s0. 00 Item: 05100 BUII-,DING DEPARTMEI{:rItem: 05600 FIRE DEPARTMEICI os/o2/2oo7 JJP* Action: AP CONDITION OF APPROVAL Cond: L2 (BI-,DG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIAI{CE. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivisioo codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SIIALL BE MADE TWENTY-T'OUR HOT]RS IN ADVAI{CE BY TELEPHONE AT 479-2135 FROM 8:00 AM - 5 PM. SIGNATURE OF OR CONTRACTOR FOR HIMSELF AND OWNET ??f 61-ooo 6 owNER TyrEL, HowARD & SAIIDRA o3/Ls/20o7 1OO OYSTER BAY RD MILLNECK NY 17-765 APPTICANT CONCEPT MECHANICAI, PO BOX 1155 AVON coLoRADO 8L620 License:314-M coNrRAcroR coNcEPT MECrrANrCArr 03/t5/2O07 phone: (970) 949-0200 PO BOX 1155 AVON COIJORADO 8l-520 I-,icense : 314 -M Desciption: ROUGH IN AND SET TWO FLOOR VECTORS AND ON PIECE OF BASEBOARD. ROUGH IN AND SET TWO WALL MOUNTED A.C. UNITS Valuation: $12.500.00 Fireplac€ Information: Restsicted:# of Gas Applianc€s: 0 # of Gas Logs: 0 # of Wood Peller 0 't***rat :t*:*)*+a+t**'t'i.t,|**:t+,tt**'ll.'|:t***'t++:t **'tt t**:i:*aa+*t:i'lr,lr,t**'i:t+'ia't*rii FEE SUMMARY Mechanicsl-- > 5250.00 Resoarant Plan Rcview- >S0. 00 Total Calculaed Fee.s-> $328 . 00 Plan Check--> S65.00 TOTAL FEES-----> S328.00 Additional Fees------ > TOWN OF VAIL DEPARTMENT OF COMMT'NITY DEVELOPMENT 75 S.FRONTAGEROAD vArL, co 81657 970-479-2138 NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M07-0031 Job Address: 174 GORE CREEK DR VAIL Location.....: THE LODGE APT CONDOS #530ParcelNo...: 210108221074 361- 6o t5- Status...: ISSLIED Applied. . : 03115/2W7 Issued. . : Mll0/2W7 Expires . .: l0lU7l2ffi7Lrgal Description: Project No : 03/t5/2OO7 Phone: (97o) 949-0200 InvestigatioD- > Will CaIl--->$0.00 $3.00 s0. 00 Total Permit Fee-----> $328.00Paym€nts-------- > g328. oo +f+it*+**+|*+|+||t,t*'**||*ti||'t***t*|t+t.|+'l|'it'lt!*|||+|+||ti!*.|ttt+:t:fj}'+'||l't:|!.*:i:ttf+|+*'* Item: 05100 BUIIJDING DEPARTT'{ENT o4/09/2oo7 JRII Action: AP Item: 05500 FIRE DEPARTMEMT CONDITION OF APPROVAL Cond: 12(BLDG.): PIETD INSPECTIONS ARE REQUIRED TO CIIECK FOR CODE COMPIJIAIICE. Cond: 22 (BLDG. ) : COHBUSTION AIR IS REQUIRED PER CHAPTER 7 OF TIIE 2003 IMC AlilD SECTION 304 OF THE 2OO3 IFGC AS MODIFIED BY TOWN OF VAIIJ. Cond: 23(BLDG.): BOIILER INSTAITLATION MUST CONFORI'{ TO MANUFACTURER'S INSTRUCTIONS A}ID CHAPTER 10 OF TITE 2OO3 TMC. Cond: 25 (BI-,DG.): GAS APPIJINiICES SIIALL BE VEIITED ACCORDfNG TO CHAPTER 5 OF TIIE 2003 IFGC. Cond: 29 (BLDG. ) : ACCESS TO MECHANICAL EQUIPMENI MUST COMPITY WrTII CHAPTER 3 OF TIIE 2003 IME AND CIIAPTER 3 OF TITE 2OO3 IFGC.. Cond: 31 (BLDG. ) : BOILERS SHAIL BE MOIINTED ON FLOORS OF NONCOUBUSTIBLE CONST. UITITESS IJISTED FOR MOIINTING OII COMBUSTfBLE FIJOORIIIG. Cond: 32(BLDG.): PERMIT,PI-,ANS AND CODE AIIA].rYSTS MUST BE POSTED IN MECIIANICAIJ ROOM PRrOR TO AN INSPECTION RSQI'EST. Cond: 30 (BLDG. ) : BOILER ROOMS SIIAIJI-, BE EQUIPPPED WIfg A FIJOOR DRArN OR OTIIER APPROVED MEANS FOR DISPOSING OF I,IQUID WASTE PER SECTION 1004.6. DECLARATIONS I hereby acknowledge that I have read this application, frlled out in full the information required, completed an accurate plot plan, and state ttnt all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this sfructure according to the lowns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordhances of the Town applicable thereto. REQT ESTS FOR INSPECTION SIIALL BE MADE TWENTY-FOIJR HOIJRS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OIJR OFFICE FROM 8:00 AM - 4 PM. TURE OF OWNER OR CTOR FOR HIMSELF AND OWNEF APPLICATIOI{ WIIL ilOT BE ACCEPTED IF I]{COilPT"ETE OR,(P.o\o 6 75 S. Frontage Rd. Vail, Golorado 81657 TOV Project #: Building Permit Mechanical Permit #: 97 V 47 9-2149 (Inspecdons) *:t**{.**:r.*K*r,F* *" l\07--oos I Provlde l{edranical Room lryoutdrawn to scaleb Indude:n l.ledranical Room Dimen3ions Al/h , ,o Cornbustion Afr Drrt 9ze amll-wtion l{[*o Ffue, Vent and Gas Llnc Slze and trrcail,{n Nlt ll€at Loee C.lcs, Equlpmcnt Cut/Spoc Sh€ets :r * * * * + 8,r FoR oFFICE USE OI{LY* * t * * * l.'r :r * * * *'r * * * * * * * * * * * :r * * * OdprFs:D.bn drd: leafird Dy: s- I Permft will not be acoepted without the following: CONTRACTOR INFORMATION Medpnical C.onbactor: Conccpl f\<-cL....-^1, ,u) 7'tt Town ofVail Req. No.: .t& 6rr{_/Vl Contact Person and Phone #'s: T^ /o s.n ?/? -o ta o E-ilaff Addi€ss.bzt-czl' ,rnd a,...,'zJ€ Fax#: E//E.-O ?.ia cont"ctor slsna*,.' fr;;hq6/ ; v. p / ;;:frU* " MECMNICAL: $/45@": Job Mdress: U4; tJobName: +-+-t / r Oie Jzice-e- o 'ou4h inseboan sef ,.t'tantt4l,1 l 11 Q €e+ 'aa-{ars Qr(dlato tu ol l- ua tt (+/ a. e. workClass: Ner'r() Addltion( ) Alteration(y') Repair( ) Other( ) Boller LocaHon: Interlor ( ) Exterior ( ) Other (Does an EHU o{st at this location: Yes ( ) No (-il Type of BHg: Single-famlly ( ) niphx ( ) Mufti-family ( r).4estaurant ( ) O$er ( ) No. of Existing Dwelling Units in thls buildlng:No. of Amrnmodation Units in this building: of Nofiypeof FlreplaesProposed:@sApdlane( ) Gastoss( ) Wood/Pellet( ) WdBuming(NOTAI.IOWED) Is this a @nversion from a to an EPA Phase II device? Yes ( ) No F:\delr\FoR}'ls\Fenn'ts\EulldirEvnedEnkaurendlf f -23-2m5. DOC rv3,nm5 rl TOWN OF VAIL 75 S.FRONTAGEROAD VAIL. CO 81657 970479-2138 Job Address: L,ocation.. ... : Parcel No...: Legal Description: Project No : PLUMBING PERMIT 174 GORE CREEK DR VAIL THE LODGE APT CONDOS #530 210108221074 ?ql or <f oG Status . , Applied. Issued . Expires . 03/L5/2Oo7 03/L5/2007 Phone: 970-949-o2oo 03/L5/2007 Phone: 970-949-02OO # of Gas Logs: 2'l So. o0 Toal Calculated Fees-- > $255.50 AdditionelFees----> ToAl Pemft Fee--*- >PaYnrnts--------- I BALANCE DUE.---.---- > DEPARTMENT OF COMMI.]NITY DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES Permit #: P0f-Wzl OWNER TYTEI,, HOWARD & SA}IDRA 1OO OYSTER BAY RD MII.,L}IECKNY LL765 APPLICANI CONCEPT MECHAIIICAIJ, INC P.O. BOX 1155 AVON co 81520 License: 189-P EONTR,ACTOR CONCEPT MECHANICAIJ, TNC P.O. BOX 1165 AVONco 81-620IJicense: 189-P Jo r -60(t ISSUED 03/t5tzw Mtrct2w rutu/2007 # of Wood Pallet: ?? $26s. so'$0.00 $265.50 $25s.50 $0.00 Descipion: ROUGH IN DWV AND WATER TO NEW FIXTURE LOY OUT. SET AND TRIM FIXTI.JRES Valuation: $13.500.00 Fireplac€ Information: Restricted: ?2 # ofGas Appliances: ?? +!lttt***++t+'rtr.:t!t**tt:i{.,r*'rd(***?+{.i!*l**'t**i+**'r'ltd.*t*:r:r+,r***'}**'r:f :r+r*** FEE SUMMARY Plumbing--- > Plan Check-- > Invesdgation- > Will Cdl-- > 5210. 00 Restuarant Plan Review- > $s2. so TOTALFEES- > $0. 00 s3.00 Item: 05100 BUILDING DEPARTIIEIII o4/09/2oo7 JRr4 Action: AP Item: 05500 FIRE DEPARI'l,tEllT CONDITION OF APPROVAL Cond: 12 (BI-,DG.): FIEL,D INSPECTIONS ARE REQUIRED TO CIIECK FOR CODE COMPLIAIICE. '|****l||**'|+i+ttt|t****ii+|*|t***'|.i|+||'|t***'|||+|ttti||ia|||t** DECLARATIONS I hereby acknowledge that I have read this application, filled out in firll the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances ard stat€ laws, ard to build this structure according to the towns zoning and suHivision codes, design review approved, International Buildhg and Residential Codes and other ordirunces ofthe Town applicable thereto. TOWNOFVAIL, COLORADO Statement Nuniber: Palment Method: Mechanical / ck LO6o2 R070000445 Amount ! check Statement $25s.s0 04/ro/20071-1 :28 AMInit: LTlilotation: Concept Permit. No:Parcel No:Site Address:Location: This Payment: ACCOT]NT ITEM IIST: Account Code P07- 0021 TI4)E: PLT,MBING PERMIT +++*******+*****'t**i++l'******++*+'i******+*+t****t*++*'f*****++*******t++**************++***** 2IOL-O82-2107 -4 174 GORE CREEK DR VAIL THE LODGE APT CONDOS #530 s26s . s0 Description Tota1 Fees:Total ALL Pnts: Balance: $265 .50 $255.50 90.00 Current Pmts PF 00100003112300 PP 00100003111100 wc 00100003112800 PIJAN CIIECK FEES PIJ]MBING PERMIT FEES WIIJIJ CA].'L INSPEMION FEE 52.50 210. O0 3 .00 APPLICATIOI{ WIII.]IOT BE AOCEPTED IF IIICOHPI"ETE OR ProJect #:o7qooA Building Plumbing Permit #: 9ro-479-2l.49 TOWN OF VAIL PLUMBING PERTTIIT APPTICATION ?b7. sqle/r-f_z-l 75 S. Frontags R||. Yail, Colondo 81657 Torrn of Vall Reg. No.: ) v.P. /s COIIPLETE VAIUATIOIT FOR PtUttlBIl{G PERIIIT (labor & t{aterials) PLUMBTNG: t 19,500"-' Otuat9 Paref * R./O/ OK Z -21074 robName: 7y fa/ R* s i/*, e<- l.€gEl Decqiption I Loft | Blodr: I Filing:SubdMdon: W-ylwi .. 4^i^ rt /.- tl'ffiry'?,"- 9rr?uP,,r frJool*n' Pa at I 2-Phone:q 4 o o work:eulht?i'rn in Dlura.Cvfztrts,ktek, zb ne*t 6'xt7tre.aqpa*,eta ' ) Herud./Work0ass: Neur() Mdltion( ) Alteraton(y') Repatr( ) Odter( TypedBfdg.: Singfefamlly( ) Dupfer( ) Muld;tardlV?t{Conrmercial glf n*unrf'( ) Oilrer( ) N,o. of Edsting Dwellirg Units in this buildlng:7 l'lo. of Accommodation Units In this bultding: 7 rl*!:.*******r***f*r**************rtr****FOR OFFIGE USE OtlLY.*****tl****rt****tt*******t********* F:WaAFORIIS\PERI{[S\edHing\drnit tg.JsflrLl 1-23-2@5.da PagE I of 1 flf,3nm/s ^ .l Sub Tvoe: AMFU'se: lll A Status: ISSUEDInsp Area: JRM Phone: 970-949'1800AND RISERS, PLUMBING FIXTURES, ELECTRICAL FIXTURES, Requested Time: 08:30 AM' Phone: 90.1-1283 Entered By: DGOLDEN K . NOTIFICATION Action: AP APPROVED lz*-lt3ooz lnspec$LT Fe,{tu??t n8Porting eage 0t Requested lnsp€ct Date: llonday, Decombor 17,2007' Insoection Area: JRll Site Address: I74 GORE GREEK DR VAIL THE LODGE APT CONDOS #530 WA, 14^ Item: 226Item: 30Item: 50Item: 60 Item: 70Item: 90 Roouosted Inspection(s) Item: 90 BLDG.FinalRequestor: BECK BUILDING COMPANYConiments: will call 904-1283Assioned To: SHAHN" Action: Time Exo: Insoection Historv ** Approved * : SHAHN. : 807-0269 REPT131 Run Id: 7396 lz*-ltSooz lnspec$$l FedlyF?t neeorting eage oz Requested Inspect Date: ilonday, Dscembor 17, 2007' Inspectlon Area: JRM Slte Address: 174 GORE CREEK DR VAIL THE LODGE APT CONDOS #530 A/P/D Information Activitv: M07-0031 Const Tvp6:Ofier: TYTEL. HContractor: CONCEPT IDescription: fi?tsn#ifi Reouested lnsoectaon(s) Inspection Historv Item: 200 Item:310Item: 315Item: 320Item: 330Item: 340Item: 390 ,lfiAonroved * Action: AP APPROVED Type: B-MECH Sub Type: AMF Status: IS-SUEDcqp_ahby: U'se: Insp Area: JRMIDRA - ,L Phone: (970) 949-0200 I/O FLOOR VECTORS AND ON PIECE OF BASEBOARD. ROUGH IN AND SET A.C. UNITS Requestod Tlme: 09:30 AItl' Phone: (970) 949-0200 Entered By: DGOLDEN K REPT131 t. Run Id: 7396 .. , A/P/D lnformatlon Conkactor:Description: Inspoctlon Historv Item: 220 Item: 230 Item:Item: Activitv: P07-0021Const Tvo6:O\,ltien TYTEL. H Requested Inspect Date:' Inspec{ion Area:Site Address: ID.W.V. * Aoproved ** Inspector: JRM ilonday, Decombert 7, 2007JRM 174 GORE CREEK DR VAIL THE LODGE APT CONDOS #530 TO NEW FIXTURE LOY OUT. SET AND TRIM FIXTURES Status: ISSUED Insp Area: JRM Requestod Tlme: 03:00 PM' Phone: 970-949-0200 -or- 331-4508 Entered By: DGOLOEN K SubTgOe: AMF Phone: 970-949-0200 Action: AP APPROVED Action: APAPPROVED 240260 290 Water * Aooroved "Insoector: JRMSTREET PRESSURE lffnroveO * Insoector: JRVENTING APPVENTING APPROVED* APProved * lnsoector: JRM'Insoector: JRM' Action: 1 SATH AND KITCHEN COMPLETE APAPPROVED PA PARTIAL APPROVAL - Action: Time Exp:Comment: -T-FATFANLFKITCHEN COMPLETE REPTl31 Run Id: 7396 OOTITi|TYEIELOFIE}{I Design Review Board ACTION FORII Department of Community Development 75 South Frontage Road, Vail, Colorado 81657 tel: 970.479.2139 tax. 970.479,2452 web: www.vailgov.com PrcJeCt Name: TYTEL RES, ADDMON Project Descrlption: Participants: 1052 MESA DRIVE P.O. BOX 1138 EAGLE co 81631 License: 882-8 Prcject Address: 174 GORE CREEK DR VAIL Legal Description: lot: A Block Subdivision: Partel Number= 2LO1-082-2L074 Comments: See@ndiitons DRB ]{umber: DR8070005 Request for an interior conversion of 110 square feet. Includes the addition of one new window and a window to be replaced by a french door. owNER TYTEI-, HOWARD & SANDM 0Ll08l2OO7 1OO OYSTER BAY RD MILTNECK NY 11755 APPLICANT WALKER BUILDING COMPANY 0L10812007 Phone: 970-328-9362 1052 MESA DRIVE P.O. BOX 1138 EAGLE co 81631 License: 882-8 CONTMCTOR WALKER BUII-DING COMPANY OUA8,|?:OOT Phone: 970-328-9362 LocaUon: THE LODGE APTCONDOS #530 LODGE APT CONDO (TlrE) Mouon By: Second By: Vote: Gonditions: BOARD/STAFF ACTION AcIiOn: STAFFAPR Date of Apprcva l= OLI LOl2007 Cond:8 (PLAN): No changes to these plans may be made without the written @nsent of Town of Vail staff and/or the appropriate review committee(s). Cond:0 (PLAN): DRB approval does not constitute a permit for building. Please consult with Town of Vail Building personnel prior to @nstruction activities. C.ond:201 ' DRB approual shall not beome ralid for 20 days follodng the date of approval. Cond: 202 Approral of this project shall hpse and become void one (1) yer following the date of final approval, unless a building permit is issued and onstructlon is commenced and is diligendy pursued to,vard completion. @ndr 113 All developrnent applicaUons submitted to the Town after the effective date of Ordinance 26, Series 2006 shall be subject to the pending employee housing regulaUons in whatarer form they are finally adopt€d; prodded, however, that if the Town fails to adopt the pending employee housing regulaBons by April 15, 2W7, this Ordinance shall not apply to such dwelopment applications. Cond: CON0@8619 The applicant shall reconstruct the aderior of the building in a manner which does make it evident where wlndows were removed or added. This may entail replacing more siding than just patching locations where windows were removed. Under no circumstanae should it be distinguishable were old and new materials meet. Cond: CON0008620 The applicant shall match all windows, doors, siding, and @lors to those existing cunendy on the s&ucture. Planner: Wanen Campbell DRB Fee Pald: t3qr.O0 allilsl26E7 2lt6r -5169222748 Jen 04 07 04:,l5p GilY D. WrI€r I |{ta-p2 970 32B 7016 *ffi AdfiEons-nedqqtel or Gornmqdal*iffiil"n for Dc.lgn n:vlar .ffi*?u|fi!ffis- S:rtr'*P'4dn i.i"frr'i'c';ietd,.|E*1figffiffiffi38ffi.?.Hfff,il1";;a*' "'--;i5;m * T- t f t, LorzdonoftletFed t b-4och-SuHfYbHri' ---'.-'-- *a r-t @(ffi Egile co' rrs'dr !t go-3zs{glo b oarcd no') tJ nl wo {ooo(lttr trr tr tirrtptur Ctlrc RtrilrG Zoolng: il6rm(t)ofm(i} lnllhgllrc o'nrtalCgl|il|fqt} r|arnedlplhanG lhifingAdcps E-nrflAddrcrr: itlDG af R.lrid tl Si$E Co.GFdferhr I|ew@Fu&rAtffil I'tnF Alhirtlon(ilrt{amffytcctrrrtdD tttrAltsrrtigt(dry:firffidc) o grrlErrte Atrordl PlilE tt SrF doo RnuGt lasfl0ll f2$ . frct lso gtlltlfi|F?$Erlffidu4nJt'' Itlo Fe! For Gorguctlqt d t tFl hfltE a &nE ilhld. Fir; ddfid| ut-t {tl''l lboalll is &b tr*lcrfia[ qm#l hrfino Fuunl 2!0 dtii''s I qFrnnnordrmgerEhng[d+irgldtg, p* tgr ffi l|ffils, F@FE|frncr fli.l tttatnh9 r*r.B |QO iailotarcgcrbhffrgsed JtcinFo'stlcnl$ ldl'r ;Jd!;Fftto; *iodi auu h&capl'R' ffi nd nirrthe rds, tle3!0 hr ilf*t5 to pb.E ll|r ltt .Deil,€d bt tlatrft|g stF a $t Dtshn Rt||!3dt|. ltbFF /rtf {30 /odS. /7 Uu/ January 4,2007 Mrs. Sandra Tytel 174 E. Gore Creek Drive Vail CO 81658 Dear Mrs. Tytel: The Board of Managers for Lodge Apartment Condominium Association has received your request to remodel your condominium. The construction will include the following projects: 1. Remodel the entire kitchen. 2. Remove all flooring and replace. 3. Remove all batbroom fixtures and replace. 4. Moving walls to facilitate bathroom remodels. 5. Additional I l0 square feet offloor space. 6. Ele.ctricalupgrades. 7. Replacement of all windows to match existing. 8. Addition of a window and reconfiguration of the balcony door. Subject to the following conditions the Board of Managers hereby approves of the proposed plans: l. An approved condominium construction document is signed and all conditions are adhered to. 2. All required permits are obtained from the Town of Vail. We wish you well in your endeavor. Sincerely, \/Bva V. Charles Viola Managing Agent Lodge Aparment Condominium Association \*€a*h 174 East Gore Creek Drive, Vail, Colorado 81652 USA Telephone (y70) 47C50t7 Facsirnile (970) 476-7425 www.rockresorts.comRocrRssoRrs PROPOSED MATERIAU; TVoe of MaterialBuildino l4aterials F: \odaAFoRMs\PERMm\Pbnning\drb-a&ition-l 1-23-2005.doc Color Roof Siding Other Wall Materials Fascia Soffits Windows Window Trim Doors Door Trim q Hand or Deck Rails Flues Flashing Chimneys Trash Enclosures Greenhouses' Retaining Walls Exterior Lighting Other ilotes: \ a Please speciff'the manufacture/s name, the color name and number and attach a color chip. a, O', 'sj ,- r r4Jtr'J 3 6r ' Y P?4,e7 of14 rLlz3l2m5 PROPOSED TANDSCAPING Botanical Name Common Name Ouantitv Size PROPOSED TREES AND SHRUBS DCSTING TREES TO BE REMOVED MinimumRequirementsforLandscapins: ffifJ:[Iffi:ilffI|!il Shrubs - 5 Gal. Tvpe Souare Footaoe GROUND COVER soD SEED IRRIGATION TYPE OF EROSION CONTROL Please specify other landscape features (i.e. retaining walls, fences, swimming pools, etc.) F:\cdev\FoRMs\PERMm\Planning\drb-addition-11-23-2005.doc Page I of 14 IU23.P005 Tr,'l*t Hr ,tri ( {90 / u/y/ ?rf j(l-b ;Jj I.tii i oz ts =eluo- ooo (\t FI o (\I c)oo (o ooo c)<\l (r, UJ IJJl!L =E[!o- Gl,l,t----- -g tlcg/s 1,/.,/sb#.1YD tuJIF lo -, aoot 6 r.r,l (o \\.cor co 6Es,Eol--r- 8rF.io;=+tltJ+r;o gt6l.*t-di=e t6 ruF F FIz o z2 oulFozo,26'! d! .6 o =2 ooo c.!(ug !c,P+,0, oo o(, ltJ 1Uoz EffiSErei ; EErg! ; le Eg: =iE;'=*rs igEi.#'.E j-oc a E;*c EEg;I :g'-siFn o1.() osf rJ)$l ot\ oo rJ)(O e o -S co c c1t': r.clt\ |r)ror.() E =uJcozo 5o Y, uJ oz J J I UJJIJJ oz =f J 9z ouI = uJuJt!zo F IJJ u/ ;uJ urez 6|lJ F atoo-llJ z ul o x Fl! <t) tn uJ UJt! ts = UJo J FoF oz oc uJJqJ (9z ao- JC =I gJ- NO|lVn]V !'Eo =2 ZtLo ootr ^ 6zg 5 =9F9 OE tnoE6d f<)zxl!<oq {oEq trEE5 =E.io.i 6g i9o!)ur S =(ON \t z tr J { Eo eo uJ F c uJE, ) z Eoo x z tr qJFJ =uJz tllltltl <,,tzlzOaEur<oo< =Hx 'r-X.i<z =z, 9z -iF do}E t_l|lll t-lll t]lcclloltoltJlI lrl UJ J-) oau,lzY9 r! F z tr oz aJ 3 F uJ ooo3 a i JI<ltrl2l zl .. >l uloulutzo = t! J zst =Fo c} zY (7) Id. Ls l-l @ r{ C\,1c)o UJ Eooo-zo EulV IIJooFF E IJJo-lro o-oo I I!Foz z oPz<oo =z o- u- :fi+ =Hg E uJ lt E9E<al€aE9?L 5E9't* = IJJ :-E E=o dtrE =*E 56E irE X>e q- €= uldtoF $l .-1 IIJF o E =Elrlo-zoF()fEFazoo nnn l- | (f,ltr)l* t,"J'Ed=€(d (Ug)EoJ (9z J I FoJ o(7) LO J F Ld(5ooJ ui =z o-)I *lFlrlJv, a (5 tt1 t-e,UJo uJ z J U' =(uJ lr'(\l @ oln UJeoo = NrjtoFl (?,strOltlrb- (\.t !c, o Eo ol.Fl EINI (|tut!-o PP(U =(ust- =tr Ed, -v! <!t-l tna IJJe T (t!. c =o{J .:zc(uD F6 (l,,.:Z a,an {JU' = =dl! I tJ)(\,o-l ^l>l oluJlq <liloz3i FI <ft\(r)sl' IrOF\<f t! uF (J F(J u.tJL.t J L =tr UJ I(\Ior-{ z oul = t! z3oF q4 cA ==JCL lalJJ J =tr o.t. oz etUJ .E -t t!oz3oF uJJ uJF tr oz ciuJ t!qz =I =g oz ouJ J ttoz3oF uiJ' UJ tLuz =o F uJ =7ot E <FGC) IJJ <zELtI F.42o JG<o()F fr3q!troI z co =Jc x, = dE =3E6 (r t-r.b =+E Fo2oC) <o(4 u)rir llJ:o I, A EED IA IJJulu-F =tuJo- I I I I I I I I tto ulcclF zIU' .93goc) !6 9.€:oq,l,! -(E6.9'6E'; a' €(q.oc3;!1,, o1'F FE ED--cOCaod)NCI -l,8ceetF\q6 P=oo oDcc(u E€oo3oooD :i'5f(D att c .e -E EJ Eeq9'o-EO.CG "3di q)i=-sE j-{, E6E'=oqt g8E c.6 ut =xYE5E O YEc-o 9cs =EPd'5 =c9d EEE E E-FbOO -'E () E;9tq! i.Y- do.o o.sFtg,- cLE*e E6:EE EQr(5= EE H- o..:rr C(! 0'-5ae $tf-9R' '5>.O G:c-=I:E8ia .i5 s9E o6tr9).r- O ED -or! an uJIuu-F EG uJ F F - =ZZU-o ootr ^ 6zi p =E.tgc 9C)!4.J2XtL <(c)(LJHA E-8 ;d (\t (, - tu z tr 8z F- uJF .. >l lu lll IJJzo! u,o. J z E o trFt E G.uro.|r EE2ZE<cLf€8E9=,Lie'EE =>E dEE b=o dE; >[E 8aE irE ;TEr{€i utooF t-'e) a)(-o Y o'2 -.--) .G. I X,J | {-.fi1=\zrE .= zo9 =eCDO =zd8 J C)z ? C)ul =! {zd 9555o r.u KE I H :'c-l t$TFl-4Jtz.t--ei 0{0nrf t- 25 'ii=z - :t _J'to a rll nNoc at,-uJE,o = IHlu;l\J lE*lN{ lo.In<t-I\Ilsteolrl<l> l() A 5N 14 N-[-'b JYll,rflr-l = I Irl"t\I L .,rtsf Isr ananul q-q -l = ldttnf'-x tK*f"l fcF\< sEI rU-1 Fo o INqIo ur 1l <l>l Itlql zl3l Fl \ I\I I\ .) sh g UJ J E E E IlLlllrlNllql--"1 ,o2 llJl JI-l->lttl zl3lolFI U t\\ ric\ t{ 0- Ia0 z oul Ja IIoz;IF Irf,I $! s =Etr ci ouJ 5l<l>l l!l zl =lotH ll IF =tr .l-l oluJl :l al>llllolzl3lolFI UJJulF (r LlJz3 FC)uJ = E -rO<FE(JuJ<zd,UJF.42 C) JE<oc)F F3 S?F',2f E9P e3fFd5 C) 6F F3g6 of. ir =+tFt-o2 oC) <c) Eg PERMIT NUMBE F PROJECT o INSPECTIONTOWN OF t,lr-t / r it'':i t,;JOB NAME WED THUR REQUEST VAIL r@ eM DATE READY FOR LOCATION: INSPECTION: CALLER TUES FRI BUILDING: D FOOTINGS / STEEL PLUMBING: O FOUNDATION / STEEL tr UNDERGROUND tr ROUGH / D.W.V. tr ROUGH / WATERtr FRAMING n ROOF & SHEEB" PLYWOOD NAILING tr GAS PIPING O INSULATION O POOL / H. TUB tr SHEETROCK NAIL tr o tr tr FINAL tr FINAL ELECTRICAL: tr TEMP. POWER MECHANICAL: tr HEATING tr tr tr ROUGH tr EXHAUST HOODS CONDUIT tr SUPPLY AIR tr tr FINAL tr FINAL frAeeaoveo i:C bonnecrroru6,. - tr DISAPPROVED tr REINSPECTION REQUIRED DAIE ,,' o. ,, ,'. .' INSPECTOR /l'-) l-1 {.-- | /U F PROJECT READY FOR LOCATION: PERMIT NUMBER O INSPECTION: JOB NAME CALLER TUES ^, -,.!{" -INSPECTION REQUEST VAILTOWN OFp {30 WED THUR FRI 3:od xa @ BUILDING: tr FOOTINGS / STEEL PL tr :{4 tr tr n UMBING: UNDERGROUND tr FOUNDATION / STEEL ROUGH / D.W,V. {rnnrurruc ROUGH / WATER rr ROOF & SHEER" PLYWOOD NAILING GAS PIPING tr INSULATION tr SHEETROCK TI POOL / H. TUB NAIL tr FINAL tr FINAL ELECTRICAL:MECHANICAL: tr tr tr n TEMP. POWER tr HEATING tr EXHAUSTROUGH HOODS CONDUIT tr SUPPLY AIR TI tr FINAL tr FINAL PROVED tr DISAPPROVED O REINSPECTION REOUIRED CORRECTIONS: INSPECTOR PERM DATE BT /; I UM b '()I/l N I.^l ./l IN rl OF ,'1,/, ) SPECTIONTOWN OF REQUEST VAILPROJECT INSPECTION: JOB NAME MON CALLER READY FOR LOCATION: f-tTUES ,/ WEq, THUR BI tr tr tr tr tr bdt\tr ILDING:PLUMBING: FOOTINGS / STEEL tr UNDERGROUND tr ROUGH / D.W.V. tr ROUGH / WATER FOUNDATION / STEEL FRAMING ROOF & SHEER PLYWOOD NAILING tr GAS PIPING INSULATION tr POOL / H, TUB SHEETROCK NAIL o tr FINAL tr FINAL ELECTRICAL: tr TEMP. POWER MECHANICAL: tr HEATING tr tr tr ROUGH N EXHAUST HOODS CONDUIT tr SUPPLY AIR D tr ^^L O FINAL ./l OVED tr DISAPPROVED tr REINSPECTION REQUIRED , CORRECTIONS: ,",/'' DATE INSPECTOR I SPE ,,1 WED THUR FRI ', IN CTION REQUEST TOWN OF VAILPERMITNUMBER OF PROJECT DATE i ,i :;'t ,loB NAME INSPECTION:MON CALLER TUES PMAMREADY FOR LOCATION: BU!LDING: tr FOOTINGS / STEEL PLUMBING: O UNDERGROUND tr ROUGH / D.W.V. tr ROUGH / WATER tr FOUNDATION / STEEL tr FRAMING ,..' ROOF & SHEER" PLYWOOD NAILING tr GAS PIPING tr INSULATION tr POOL / H. TUB tr SHEETROCK NAIL tr trtr tr FINAL tr FINAL ELECTRIGAL: tr TEMP. POWER MEGHANICAL: tr tr tr tr HEATING tr tr tr ROUGH EXHAUST HOODS CONDUIT SUPPLY AIR FINAL tr FINAL tr APPROVED CORRECTIONS: tr DISAPPROVED tr.REINSPECTION REQUIRED DATE INSPECTOR I SPE CTIONTOWN OF REQUEST VAILPERMIT NUMBER OF PROJECT //NAME -- t t' IN t-l ;'/ ./ READY FOR LOCATION: AM igl-):'' .t' /L/ BUILDING: tr FOOTINGS / STEEL PLUMBING: tr UNDERGROUND T] ROUGH / D.W.V. tr ROUGH / WATER tr FOUNDATION / STEEL tr FRAMING ROOF & SHEER PLYWOOD NAILING tr GAS PIPING INSULATION tr POOL / H. TUB tr SHEETROCK NAIL tr FINAL tr HEATING tr ROUGH tr EXHAUST HOODS tr CONDUIT tr SUPPLY AIR tr DISAPPROVED tr BEINSPECTION REQUIRED , CORRECTIONS: t DATE INSPECTOR Rusty Spike Enterpriser .c. Box l5l7 vAtL, coLoRADO 81657 Home 476.1331 Eusiness: 476-4974 tl! rTI -,rrl.. G -)'i-1.'l , L-l .l ^i)ra t, rt n )lJ ila, l. 'rlj- I r.l r' .;l::5 ,l r,L -..'"'i." I,Il ,.- I , j, ,i) . i -ti\ '1r- : ,' ' : ,' .. i;. il-;l r.r L l .-:^, 1\- r ,' -:. 1 _r EIGNEDN PLEASE REPLY J ilo REPLY NECESAARY PERMTT Tr,r"T. oF lRoJEcr CTION REQUEST TOWN OF VAIL e SPE ,:- jJ l JOB NAME CALLER MON TUES THUR / FRI IN READY FOR INSPECTION: I:.1ll LOCATION: WED tr FOUNDATION / STEEL PLUMBING: tr UNDERGROUND tr ROUGH / D.W.V. tr ROUGH / WATERtr FRAMING r-1 ROOF & SHEER" PLYWOOD NAILING tr GAS PIPING tr INSULATION tr SHEETROCK tr POOL / H. TUB MEGHANICAL: tr TEMP. POWER tr HEATING tr ROUGH tr EXHAUST HOODS tr coNoutr tr SUPPLY AIR ,APPROVED CORRECTIONS: tr DISAPPROVED tr REINSPECTION REQUIRED DATE INSPECTOR Gary Town of Vail Building Dept.Vail, Colo 81657 Gary: Enclosed is the letter of variancefrom the owner of the Lodqe at Vail unit ENTERPRISES p. o. box 1517 vail, colorado 81658 L2/22/8s l_r /"4 ested this is not adequate please let me know and I will do whatever else you require. If you would like to speakwith the owner directly I can either set that up for you or the owner can be reached at the Lodge. His name is Bert Kl-ett. Regarcling the matter of the spacing of the balustersin this unit (+530), I measured those is unit 11527,at the Lodge at Vail-,and found them to be as much aseight inches between the balusters (this is not 8" on center but 8" between) . Thank you for your cooperation regarding inspection ofthis unit. ,4.'h'/ /' .//#Ki,4ffi*- n (h$ fuw" N6N la L2/22/8s Building Department Town of VailVail, Colo 81557 To Whom It May Concern: I reepeetfully requeat a variance to the present staircode for the redesign of two steps. These steps arein the stairway of my unit #530, The Lodge at Vail .By redesigning theEe two steps, I have matched them toother existing steps of this winding unit. This changemaintains a continuity with the rest of the stairway.This change improves the flow between the leve1s in the unit.Thank yorlF_(eBert Klett August 21" 1985 To Whom it May Concern: In my capacity of Director of Propert ies I have examinedthe plans of renovation/decoration of unit 530 at the Lodgeat Vail. These pl ans i mprovements S incqrel y su Assistant Manaqer CVB:k1g are approved and we I ook forward to seei ng the proposed by the owner - Mr" Burt Klett. 174 &r^st C,ore C.."tO.* \hil, Orlorado 81657 303-476-54 Telex 45-0375